1 Thermo-Finnigan LCQ Interface Manual For Thermo Finnigan LCQ XP, Deca, Advantage, Duo, and Classic Models Version IonSense Inc. 999 Broadway Suite 404 Saugus, MA 01906

2 Copyright by IonSense Inc. All rights reserved. The information in this document has been carefully checked and is believed to be reliable. However, no responsibility is assumed for inaccuracies. Statements in the document not intended to create any warranty, expressed or implied. Specification and performance characteristics of the hardware and software described in the manual may be changed at any time without notice. IonSense Inc. reserves the right to make changes in any product herein in order to improve reliability, design, or function. IonSense does not assume any liability arising out of application or use of any product or circuit described nor does it cover any license under its patent rights or the rights of others. The apparatus and application of the apparatus described in this document is protected by US Patent Number 6,949,741 and used under license; additional patents pending. All trademarks are properties of their respective owners. 2

3 This manual details the steps necessary to install a DART source on a Thermo-Finnigan LCQ mass spectrometer. Table of Contents Installing the DART on The LCQ Deca and Classic Models... 4 Installing the DART on LCQ XP, Duo, and Advantage Models... 7 Recommended Optimal Settings

4 Installing the DART on The LCQ Deca and Classic Models First, place the mass spectrometer in standby mode and remove the Thermo-Finnigan source from the LCQ mass spectrometer. Clean the source region and the end of the heated capillary. Figure1: The LCQ Deca and Classic DART flange with nuts and interlock pin Next, place the interlock pin in the small hole in the bottom-right corner on the back of the flange. Figure 2: The interlock pin inserted into the hole on the back of the flange 4

5 Attach the flange by holding the flat side on the bottom. Take care that the interlock pin does not fall out while pressing it into the flange. If you are using a DART SVP source, screw the two interlock pins into the holes highlighted in the figure below. (Your flange may not have the same number of holes as the flange shown in the picture below.) On the bottom of the source, remove the waste line if you have not done so already. Take the black silicone rubber tubing and attach the open end to the waste port. The other end should be attached to a vacuum source, either the Vacuubrand pump ordered from IonSense, or another pumping source provided by the user. 5

6 The silicone rubber tubing connected to the waste port. Insert the ceramic tube into the Swagelok nut on the end of the VAPUR attachment and secure it with the graphite ferrule. Take care that there is a 2mm gap inside the VAPUR between the end of the ceramic tube and the protruding end of the Agilent capillary. This ensures that the excess helium gas will be evacuated and maintain proper vacuum in the instrument. Finally, attach the DART by either securing the two captured screws in the front ring to the flange, or removing the ring and bolting the two holes on the front of the DART base to the bottom of the flange. 6

7 Installing the DART on LCQ XP, Duo, and Advantage Models To install the DART on the LCQ XP, Duo, or Advantage, follow the same procedure as above with the larger extended-barrel SI-110 flange. One notable difference between the SI-100 (LCQ Deca) and the SI-110 (LCQ XP) flanges are that the LCQ XP flange has the interlock pin fastened to the flange. It does not need to be inserted or removed. s 7

8 Recommended Optimal Settings These settings are intended as a rough guideline under which to operate your LCQ-DART. IonSense recommends tuning the mass spectrometer yourself with your desired analyte. These settings may not be optimal on every model of LCQ and some settings may not exist or be variable on other models. For LCQ Deca Models: ESI Source (Positive Mode) Sheath Gas Flow Rate (arb): 0 Aux Gas Flow Rate (arb): 0 Spray Voltage (kv): 0 Capillary Temp (C): Capillary Voltage (V): Tube Lens Offset (V): 0.00 Ion Optics (Positive Mode) Multipole 1 Offset (V): Lens Voltage (V): Multipole 2 Offset (V): Multipole RF Ampliture (V p-p): Entrance Lens (V): ESI Source (Negative Mode) Sheath Gas Flow Rate (arb): 0 Aux Gas Flow Rate (arb): 0 Spray Voltage (kv): 0 Capillary Temp (C): Capillary Voltage (V): Tube Lens Offset (V): 0.00 Ion Optics (Negative Mode) Multipole 1 Offset (V): Lens Voltage (V): Multipole 2 Offset (V): 7.00 Multipole RF Ampliture (V p-p): Entrance Lens (V):

Thermo-Finnigan LCQ Interface Manual

Thermo-Finnigan LCQ Interface Manual Thermo-Finnigan LCQ Interface Manual For Thermo Finnigan LCQ XP, Deca, Advantage, Duo, and Classic Models Rev 2 Document # 7.5.062 IonSense Inc. 999 Broadway Suite 404 Saugus, MA 01906 Copyright 2005-2010

More information

DART-Thermo LTQ/Orbitrap Interface Manual

DART-Thermo LTQ/Orbitrap Interface Manual DART-Thermo LTQ/Orbitrap Interface Manual For Thermo LTQ (Orbitrap) Velos, LTQ Orbitrap XL, LTQ Ion Trap, Exactive High Performance, and all other instruments that utilize the Ion Max Source Version 20120423

More information

Thermo Finnigan LCQ Advantage Getting Started

Thermo Finnigan LCQ Advantage Getting Started This chapter provides infonnation on optimizing the tune of your MS detector in the APCI/MS high flow mode. It is not necessary to recalibrate the MS detector when you switch to APCI/MS operation. You

More information

An Introduction to Mass Spectrometry

An Introduction to Mass Spectrometry An Introduction to Mass Spectrometry Guy Wilson UPC 2 & Purification Business Development, Northern Europe, Waters Ltd 2013 Waters Corporation 1 What is a Mass Spectrometer? Data System Sample Introduction

More information

Plasma-Therm 790 RIE (Reactive Ion Etcher) Basic Operation Guide

Plasma-Therm 790 RIE (Reactive Ion Etcher) Basic Operation Guide Plasma-Therm 790 RIE (Reactive Ion Etcher) Basic Operation Guide Description: The Plasma-Therm 790 is configured for RIE (Reactive Ion Etching) processing of Silicon substrates. Substrates up to 8 inches

More information

Fisher ENVIRO-SEAL Bellows Seal Bonnets

Fisher ENVIRO-SEAL Bellows Seal Bonnets ENVIRO-SEAL Bellows Seal D06X0 Product Bulletin September 07 Fisher ENVIRO-SEAL Bellows Seal Bonnets ENVIRO-SEAL bellows seal bonnets improve sealing capabilities of Fisher valves and provide long life

More information

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated SPECIFICATIONS 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature The 86 compensated is a small profile, media compatible, piezoresistive silicon pressure sensor packaged

More information

Scientific vapor pumps

Scientific vapor pumps Scientific vapor pumps Vapor pumps for scientific instruments and R&D applications Diffusion pumps - technology and applications - EO series -4 Diffstak -8 Cryo cooled diffstak - Unvalved diffstak -6 Diffstak

More information

Linkam Scientific Instruments USER GUIDE TS1500 TS1200 TS1000. High Temperature Stage

Linkam Scientific Instruments USER GUIDE TS1500 TS1200 TS1000. High Temperature Stage Linkam Scientific Instruments TS1500 TS100 TS1000 High Temperature Stage USER GUIDE Contents Before Setting Up your Equipment... 3 Important Notice... 4 Warranty... 4 Technical Support... 4 Equipment Maintenance...

More information

Truck Edition V-220 / V-320 Series Single Temperature Systems TK IM (Rev. 0, 06/17)

Truck Edition V-220 / V-320 Series Single Temperature Systems TK IM (Rev. 0, 06/17) Installation Manual Truck Edition V-220 / V-320 Series Single Temperature Systems TK 56321-18-IM (Rev. 0, 06/17) Installation Manual Truck Edition V-220 / V-320 Series Single Temperature Systems TK 56321-18-IM

More information

Light Level Detector, Surface Mount 5754PE. Installation Instructions

Light Level Detector, Surface Mount 5754PE. Installation Instructions Light Level Detector, Surface Mount 5754PE Contents 1.0 Introduction 3 2.0 Safety and Product Handling 3 3.0 Installation 4 3.1 Removing the Top Cover 4 3.2 Installing the Mounting Hardware 4 3.3 Mounting

More information

Universal NanoFlow Sprayer Installation and Maintenance Guide

Universal NanoFlow Sprayer Installation and Maintenance Guide Universal NanoFlow Sprayer Installation and Maintenance Guide 71500110107/Revision C Copyright Waters Corporation 2007 All rights reserved Copyright notice 2007 WATERS CORPORATION. PRINTED IN THE UNITED

More information

NX8601BF-AA. Data Sheet R08DS0109EJ0100 Rev.1.00 Apr 19, 2013 LASER DIODE DESCRIPTION FEATURES

NX8601BF-AA. Data Sheet R08DS0109EJ0100 Rev.1.00 Apr 19, 2013 LASER DIODE DESCRIPTION FEATURES A Business Partner of Renesas Electronics Corporation. NX8601BF-AA LASER DIODE 1 625 nm InGaAsP MQW-DFB LASER DIODE COAXIAL MODULE FOR OTDR APPLICATION Data Sheet R08DS0109EJ0100 Rev.1.00 DESCRIPTION The

More information

Troubleshooting the MPH 24FP Series Pedestal Hydrant

Troubleshooting the MPH 24FP Series Pedestal Hydrant MAPA Products P.O. Box 129 Naples, Texas 75568 Toll Free: 877 897 2371 How the Hydrant Works: Troubleshooting the MPH 24FP Series Pedestal Hydrant The design of the hydrant assembly is based on a venturi

More information

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated SPECIFICATIONS 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated The 82 constant voltage is a 19 mm small profile, media compatible, piezoresistive

More information

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated Compensated SPECIFICATIONS 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated The 86 compensated is a small profile, media compatible, piezoresistive silicon

More information

Small Box for Cable Termination. 3.1 Preparation of box 3.3 Mounting of the box on the wall

Small Box for Cable Termination. 3.1 Preparation of box 3.3 Mounting of the box on the wall FIST-SB2-8 I N S T A L L A T I O N I N S T R U C T I O N Small Box for Cable Termination Contents 1 Introduction 1.1 Product description 2 General 2.1 Tools 2.2 Kit contents 3 Installation and pre-assembling

More information

Technical specifications of FT-IR Spectrometer

Technical specifications of FT-IR Spectrometer Technical specifications of FT-IR Spectrometer We would like to buy a FT-IR spectrometer which has to be integrated with a Gas Chromatograph with the following technical specifications. 1. The spectrometer

More information

Netbiter Tank Sensor

Netbiter Tank Sensor For Netbiter Tank Sensor HMS Industrial Networks AB Post address: Box 4126 300 04 Halmstad SWEDEN Visitor s address: Stationsgatan 37 302 45 Halmstad SWEDEN Telephone: + 46 35 17 29 00 Fax: + 46 35 17

More information

MODEL 4000A & 4001A ACCELEROMETER

MODEL 4000A & 4001A ACCELEROMETER MODEL 4000A & 4001A ACCELEROMETER dimensions 4001A Connector Attachment SPECIFICATIONS Silicone MEMS Accelerometer Signal Conditioned Output Temperature Calibrated Low Cost, Lightweight The Model 4000A

More information

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated Compensated SPECIFICATIONS 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated The 86 compensated is a small profile, media compatible, piezoresistive silicon

More information

THERMAL VACUUM TESTS OF A FIVE WATT PSEUDO CHIP SEM-X ELECTRONIC MODULE CLAMPED IN A SATELLITE BOX

THERMAL VACUUM TESTS OF A FIVE WATT PSEUDO CHIP SEM-X ELECTRONIC MODULE CLAMPED IN A SATELLITE BOX IN A THERMAL VACUUM TESTS OF A FIVE WATT PSEUDO CHIP SEM-X ELECTRONIC MODULE CLAMPED IN A SATELLITE BOX William H. Greenwood and Ronald L. Akau Sandia National Laboratories PO Box 5800 Albuquerque, New

More information

92831 TEL: (714) FAX:

92831 TEL: (714) FAX: Document No. 1800-11 High-Performance Vacuum/Nitrogen Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton,

More information

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated SPECIFICATIONS 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature The 85 compensated is a small profile, media compatible, piezoresistive silicon pressure sensor packaged

More information

Agilent InfinityLab Online SPE Solution

Agilent InfinityLab Online SPE Solution Agilent InfinityLab Online SPE Solution Instruction Agilent Online SPE Solution - Instruction Technical Information about the Agilent InfinityLab Online SPE Solution. The following possible set-ups are

More information

TIMS TIMS. Thermal Ionisation Mass Spectrometry.

TIMS TIMS. Thermal Ionisation Mass Spectrometry. TIMS Thermal Ionisation Mass Spectrometry www.nu-ins.com Incorporating our field-proven Zoom lens multi-collector technology, the TIMS improves the versatility and overall performance of this long established

More information

Agilent 1290 Infinity II Online SPE Solution

Agilent 1290 Infinity II Online SPE Solution Agilent 1290 Infinity II Online SPE Solution Instruction Agilent Online-SPE-Solution - Instruction Technical Information about the Agilent Online-SPE-Solution (optional setups with: G4242A Online-SPE Starter

More information

PHOENIX L300i New Standards in Helium Leak Testing The next Generation

PHOENIX L300i New Standards in Helium Leak Testing The next Generation PHOENIX L300i New Standards in Helium Leak Testing The next Generation 180.85.02 PHOENIX L300i PHOENIX L300i Helium Leak Detector A Premium Class Helium Leak Detector The PHOENIX L300i helium leak detector

More information

Installing the Agilent CE ESI-MS Sprayer Kit (G1607A)

Installing the Agilent CE ESI-MS Sprayer Kit (G1607A) s1 Installing the Agilent CE ESI-MS Sprayer Kit (G1607A) This note describes how to connect an Agilent capillary electrophoresis system to an Agilent mass selective detector (G1946A). Typical method parameters

More information

2016 Ideal Vacuum (505) V 1.1

2016 Ideal Vacuum (505) V 1.1 Doc. Ref. IdealCUBE-6x121416 pg. 1 User Manual Table of Contents 6x6x6 Vacuum Cube Specification Sheet...3 Assembling a Vacuum Cube system...3 Vacuum Cube Frame...3 Plate Installation...4 Mounting for

More information

Q Trap LC/MS/MS TurboIonSpray Ion Source Manual. About This Manual... 1 Conventions Introduction... 3 Features... 4

Q Trap LC/MS/MS TurboIonSpray Ion Source Manual. About This Manual... 1 Conventions Introduction... 3 Features... 4 Q Trap LC/MS/MS TurboIonSpray Ion Source Manual Table of Contents Table of Contents About This Manual................................................ 1 Conventions.........................................................

More information

API 2000 LC/MS/MS TurboIonSpray Ion Source Manual

API 2000 LC/MS/MS TurboIonSpray Ion Source Manual Table of Contents API 2000 LC/MS/MS TurboIonSpray Ion Source Manual Table of Contents API 2000 TurboIonSpray Ion Source Manual....1 AboutThisManual...1 Introduction...1 TurboIonSpraySourceComponents...3

More information

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154. SPECIFICATIONS Low Cost 316L Stainless Steel or Titanium 19mm Diameter Package 0-100mV Output Gage and Absolute Wide Compensated Temperature Range The 154BC is a 19mm small profile, media compatible, piezoresistive

More information

EOTec 2C32 Installation Guide

EOTec 2C32 Installation Guide ControlNet Dual Ring Modules For the EOTec 2000 Series November 2008 Weed Instrument Company, Inc. 707 Jeffrey Way, P.O. Box 300 Round Rock, TX 78680-0300 USA Tel: 512-434-2850 Fax: 512-434-2851 E-mail:

More information

1320 Detectors. 1 of 30. Jun Illustrated Parts Breakdown Agilent 6890 Gas Chromatograph Service Manual

1320 Detectors. 1 of 30. Jun Illustrated Parts Breakdown Agilent 6890 Gas Chromatograph Service Manual 20 Detectors This section contains an illustrated parts breakdown for each of the following 6890 GC detectors and related components. Electron Capture Detector (ECD) Flame Ionization Detector (FID) Nitrogen

More information

UHV Flow Cryostats. Ultra High Vacuum Flow cry stats CRYO INDUSTRIES

UHV Flow Cryostats. Ultra High Vacuum Flow cry stats CRYO INDUSTRIES UHV Flow Cryostats Ultra High Vacuum Flow cry stats INDUSTRIES Ultra High Vacuum Flow Cryostats: Models RC-102 and RC-110 Cryo offers Models RC-102 and RC-110 Ultra High Vacuum continous flow cryostats,

More information

ELD500 PRECISION LEAK DETECTOR

ELD500 PRECISION LEAK DETECTOR uvhts.com ELD500 PRECISION LEAK DETECTOR THE PARTNER OF CHOICE Edwards is a world leader in the design, technology and manufacture of vacuum pumps with over 95 years of history and more than 75 years of

More information

Integrated Process Solutions. Series 49. Thermal Management System

Integrated Process Solutions. Series 49. Thermal Management System w w w. m k s i n s t. c o m Integrated Process Solutions Series 49 Thermal Management System The COMPLETE THERMAL MANAGEMENT Solution Controller Heater User Interface Series 49 Thermal Management System

More information

MPL3115A2 Sensor Toolbox User s Guide

MPL3115A2 Sensor Toolbox User s Guide Freescale Semiconductor Document Number: MPL3115A2STUG User s Guide Rev. 0, 04/2012 MPL3115A2 Sensor Toolbox User s Guide 1 Introduction The Freescale DEMOSTBMPL3115A2 Sensor Toolbox provides the hardware

More information

Customized MCPs for Analytical Instruments. An MCP for every application

Customized MCPs for Analytical Instruments. An MCP for every application Customized MCPs for Analytical Instruments An MCP for every application What are Microchannel Plates? (MCPs) Microchannel plates (MCPs) are solid state detectors consisting of parallel arrays of tiny single

More information

MODEL 834M1 ACCELEROMETER

MODEL 834M1 ACCELEROMETER SPECIFICATIONS Triaxial Piezoelectric Accelerometer

More information

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES SPECIFICATIONS Low Cost 316L Stainless Steel or Titanium 19mm Diameter Package 0-100mV Output Gage and Absolute Wide Compensated Temperature Range FEATURES O-Ring Mount -20ºC to +85ºC Compensated Temperature

More information

HISTORY OF VARIAN CAPILLARY INJECTORS

HISTORY OF VARIAN CAPILLARY INJECTORS HISTORY OF VARIAN CAPILLARY INJECTORS by Randall Bramston-Cook Lotus Consulting 5781 Campo Walk Long Beach, Ca 90803 310/569-0128 714/898-7461 Fax and Herb Neumann Varian, Inc. 2700 Mitchell Drive Walnut

More information

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage FEATURES Weldable and Threaded Process Fittings -40ºC to +125ºC Operating Temperature ±0.1% Pressure Non Linearity Solid State Reliability APPLICATIONS Medical Instruments Process Control Fresh & Waste

More information

AE R4 July 2015 Guide for the Use of R-290 Refrigerant in Copeland Refrigeration Compressors

AE R4 July 2015 Guide for the Use of R-290 Refrigerant in Copeland Refrigeration Compressors July 2015 Guide for the Use of R-290 Refrigerant in Copeland Refrigeration Compressors TABLE OF CONTENTS Safety Safety Instructions... 2 Safety Icon Explanation... 2 Instructions Pertaining to Risk of

More information

Simplicity. Reliability. Performance. Stratum. Automated VOC Sample Prep System

Simplicity. Reliability. Performance. Stratum. Automated VOC Sample Prep System Simplicity Reliability Performance Stratum Automated VOC Sample Prep System The Stratum Purge and Trap Concentrator (PTC) is a sample preparation instrument used to remove Volatile Organic Compounds (VOCs)

More information

Refrigerated Cooling System

Refrigerated Cooling System 109 Lukens Drive New Castle, DE 19720 Thermal Analysis & Rheology A SUBSIDIARY OF WATERS CORPORATION Refrigerated Cooling System Manual Addendum For use with the following: DSC 10, 910, 912, 2010, 2910

More information

Agilent 6400 Series. Maintenance Guide. Agilent Technologies

Agilent 6400 Series. Maintenance Guide. Agilent Technologies Agilent 6400 Series Triple Quad LC/MS Maintenance Guide Agilent Technologies Notices Agilent Technologies, Inc. 2010 No part of this manual may be reproduced in any form or by any means (including electronic

More information

MS4525DO SPECIFICATIONS FEATURES APPLICATIONS

MS4525DO SPECIFICATIONS FEATURES APPLICATIONS FEATURES PSI Pressure Ranges PCB Mountable Digital Output Barbed Pressure Ports APPLICATIONS Blocked Filter Detection Altitude and Airspeed Measurements Medical Instruments Fire Suppression System Panel

More information

ISO INTERNATIONAL STANDARD. Essential oils Analysis by gas chromatography on chiral capillary columns General method

ISO INTERNATIONAL STANDARD. Essential oils Analysis by gas chromatography on chiral capillary columns General method INTERNATIONAL STANDARD ISO 22972 First edition 2004-05-15 Essential oils Analysis by gas chromatography on chiral capillary columns General method Huiles essentielles Analyse par chromatographie en phase

More information

Using the Model 1500 Portable Chilled Mirror Hygrometer

Using the Model 1500 Portable Chilled Mirror Hygrometer APPLICATION NOTE 2016_0120 MODEL 1500 Rev C Using the Model 1500 Portable Chilled Mirror Hygrometer The Model 1500 is a portable, multi-function, optical chilled mirror hygrometer designed to accurately

More information

Pro-MAX Ultraviolet Sterilizer

Pro-MAX Ultraviolet Sterilizer Pro-MAX Ultraviolet Sterilizer Lifegard Aquatics introduces the Pro-MAX UV Sterilizer, featuring a patent-pending, flow-through design with less restrictive angled inlet and outlet ports requiring less

More information

Bottle cooler controllers Solutions for static, ventilated and open coolers

Bottle cooler controllers Solutions for static, ventilated and open coolers Bottle cooler controllers Solutions for static, ventilated and open coolers XRB Bottle cooler controllers The XRB series is the high-efficiency range of products available in 2 versions, standard and advanced

More information

Experience In Motion. SIHI LEMD Compact Liquid Ring Vacuum Pump

Experience In Motion. SIHI LEMD Compact Liquid Ring Vacuum Pump Experience In Motion SIHI LEMD Compact Liquid Ring Vacuum Pump Reduced lifecycle cost and increase reliability in industrial vacuum pump applications The SIHI LEMD range of close-coupled liquid ring vacuum

More information

AGILENT VS SERIES LEAK DETECTORS

AGILENT VS SERIES LEAK DETECTORS Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) AGILENT VS SERIES LEAK DETECTORS Wide range, high performance systems Features and Benefits Easy-to-Use - Two Button

More information

DM60-xxx Antennas. 1. Assembly. Installation Instruction for CMAX Antennas

DM60-xxx Antennas. 1. Assembly. Installation Instruction for CMAX Antennas Installation Guide for CMAX-DM20/DM22S/DM30/ DM60-xxx Antennas Note: Please read the complete description before starting the installation. Be sure that connectors are properly sealed from water if no

More information

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick CAN OBD READER REFERENCE DESIGN KIT USER GUIDE 1. Standard ToolStick Handling Recommendations The ToolStick Base Adapter and daughter cards are distributed without any protective plastics. To prevent damage

More information

High Temperature High Pressure Cell User Manual

High Temperature High Pressure Cell User Manual High Temperature High Pressure Cell User Manual 2I-05850 Issue 16 High Temperature High Pressure Cell User Manual 2I-05850 Issue 16 User Manual High Temperature High Pressure Cell P/N GS05850 CONTENTS

More information

Automation and Energy Efficiency of Industrial Refrigeration Systems

Automation and Energy Efficiency of Industrial Refrigeration Systems Automation and Energy Efficiency of Industrial Refrigeration Systems E360 Forum Chicago, IL October 5, 2017 Mike Micak Director of Sales Logix Controls Introduction Management thinker Peter Drucker was

More information

Reacti-Therm I and III Heating Modules

Reacti-Therm I and III Heating Modules INSTRUCTIONS Reacti-Therm I and III Heating Modules TS-18822 TS-18824 Number TS-18822 TS-18824 Description Reacti-Therm I Heating Module (single block) Reacti-Therm III Heating Module (triple block) 2101.1

More information

Duct Mount. Installation Instructions

Duct Mount. Installation Instructions Duct Mount Installation Instructions 00809-0600-4975 Legal Notice The Flame Detector described in this document is the property of Rosemount. No part of the hardware, software, or documentation may be

More information

Dolphin 9900 Mobile Computer

Dolphin 9900 Mobile Computer Dolphin 9900 Mobile Computer with Windows Mobile 6 Quick Start Guide Dolphin 9900 Quick Start Guide Out of the Box Verify that the box contains the following items: Dolphin 9900 mobile computer (the terminal)

More information

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost SPECIFICATIONS PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost The MS1471 is a piezoresistive silicon pressure sensor packaged in a surface mount configuration. It is intended

More information

Advances in Leak Detection in the Manufacturing Process

Advances in Leak Detection in the Manufacturing Process Advances in Leak Detection in the Manufacturing Process Víctor Hermosillo / Michael Broglio / Mike Kelly ALSTOM Grid Inc., 1 Power Lane, Charleroi, PA 15022 Agenda 1. Introduction 2. SF 6 Leak Detection

More information

MicrOTDR. Optical Fault Locator. User Manual

MicrOTDR. Optical Fault Locator. User Manual Optical Fault Locator Datacom Textron 11001 31 st Place West Everett, WA 98204 TEL: 425-355-0590 Toll Free: 800-468-5557 FAX: 425-290-1600 Internet: www.datacom.textron.com Warranty The MicrOTDR Optical

More information

SprintIR -W CO2 Sensor

SprintIR -W CO2 Sensor Datasheet SprintIR -W CO2 Sensor Measurement range: 0-5%; 0-20%; 0-100% Battery applications Low power Fast response Long lifetime Tel: +44 (0) 1236 781 900 info@gassensing.co.uk www.gassensing.co.uk Benefits

More information

SN5446A, 47A, 48, SN54LS47, LS48, LS49 SN7446A, 47A, 48, SN74LS47, LS48, LS49 BCD-TO-SEVEN-SEGMENT DECODERS/DRIVERS

SN5446A, 47A, 48, SN54LS47, LS48, LS49 SN7446A, 47A, 48, SN74LS47, LS48, LS49 BCD-TO-SEVEN-SEGMENT DECODERS/DRIVERS PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include

More information

ToolStick Debug Adapter

ToolStick Debug Adapter ToolStick Debug Adapter TOOLSTICK DEBUG ADAPTER USER S GUIDE 1. Handling Recommendations To enable development, the ToolStick Base Adapter and daughter cards are distributed without any protective plastics.

More information

40/40 Duct Mount P/N Installation Guide. Document Ref: TM777670, Rev. (3) June 2017

40/40 Duct Mount P/N Installation Guide. Document Ref: TM777670, Rev. (3) June 2017 40/40 Duct Mount P/N 777670 Installation Guide Document Ref: TM777670, Rev. (3) June 2017 8200 Market Blvd, Chanhassen, MN 55317, USA Phone: +1 (973) 239 8398 Fax: +1 (973) 239 7614 Website: www.spectrex.net

More information

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD PICKUP

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD PICKUP specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1960-66 FORD PICKUP CONTROL & OPERATING INSTRUCTIONS The controls on your new Perfect

More information

Development of a dry fabric cleaner for miniature parallel optical interface PRIZM LightTurn connector

Development of a dry fabric cleaner for miniature parallel optical interface PRIZM LightTurn connector Development of a dry fabric cleaner for miniature parallel optical interface PRIZM LightTurn connector March 7, 2011 Toshiaki Satake, Brian Teague, Jillcha Wakjira, Alan Ugolini and Darrell Childers US

More information

COGEIM COGEIM EQUIPMENT MAINTENANCE AND REFURBISHMENT A NECESSARY CHOISE Number 1 filter-dryer supplier in the world

COGEIM COGEIM EQUIPMENT MAINTENANCE AND REFURBISHMENT A NECESSARY CHOISE   Number 1 filter-dryer supplier in the world COGEIM Number 1 filter-dryer supplier in the world COGEIM EQUIPMENT MAINTENANCE AND REFURBISHMENT A NECESSARY CHOISE WWW.3V-TECH.COM 3V-TECH SERVICES AFTER-SALES DIVISION PREVENTIVE MAINTENANCE EMERGENCY

More information

TCS Heater System Installation and Operation Manual

TCS Heater System Installation and Operation Manual Safety Carefully read and understand this entire document. This important information will maximize safety, heater performance, efficiency and system life. All heating elements inherently pose burn, fire

More information

Model gffoz Process Ozone Sensor (In-Line)

Model gffoz Process Ozone Sensor (In-Line) Date ECO# Rev Description Originator 9/15/97 1.0 First Publication DB 10/8/97 2.0 Miscelaneous corrections DB 10/28/97 3.0 Minor changes BM 5/1/98 3.1 Added CE compliance BM TM IN USA, INCORPORATED 87

More information

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314) Mass Sensors, Inc. 1350 Baur Blvd, St. Louis, MO 63132 (314) 997-5779 www.mass-sensors.com Innovations in chemical microsensors Profile Mass Sensors is a development stage high-tech company operating in

More information

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER INSTRUCTIONS FOR SAFE OPERATIONS LM000 EXPLOSION PROOF LASER DISTANCE METER www.cord-ex.com CONTENTS READ THIS FIRST Read This First Liability Trademark Information Product Information Special Conditions

More information

Fixed Speed Rotary Screw Compressors UP6S Series hp (11-22 kw)

Fixed Speed Rotary Screw Compressors UP6S Series hp (11-22 kw) Fixed Speed Rotary Screw Compressors UP6S Series 15-30 hp (11- kw) More Than 145 Years of Compressed Air Innovation Ingersoll Rand introduced its first air compressor in 187. Over the next 145 years, we

More information

Heat Exchanger Block Replacement Instructions

Heat Exchanger Block Replacement Instructions Series 1-4 Gas-fired water boiler Heat Exchanger Block Replacement Instructions Ultra-80 S1-4 Heat Exchanger Block Replacement Kit, Part No. 383-500-773 Ultra-105 S1-4 Heat Exchanger Block Replacement

More information

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date: Installation and Operating instructions for C9900-U330-0010 battery pack Version: 2.0 Date: 2017-03-23 Table of contents Table of contents 1 Foreword 3 1.1 Notes on the Documentation 3 1.1.1 Liability

More information

Bridge to Splice Presser 710-BSP

Bridge to Splice Presser 710-BSP Bridge to Splice Presser 710-BSP Instructions November 2004 78-8135-2810-2-B 1.0 General 1.1 The 3M Bridge to Splice Presser 710-BSP is a hand tool used to press 3M Bridge Modules 710 and 3M Splice or

More information

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

INSTALLATION GUIDE. AXIS A1001 Network Door Controller INSTALLATION GUIDE AXIS A1001 Network Door Controller Liability Every care has been taken in the preparation of this document. Please inform your local Axis office of any inaccuracies or omissions. Axis

More information

DR Series Appliance Cleaner Best Practices. Technical Whitepaper

DR Series Appliance Cleaner Best Practices. Technical Whitepaper DR Series Appliance Cleaner Best Practices Technical Whitepaper Quest Engineering November 2017 2017 Quest Software Inc. ALL RIGHTS RESERVED. THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 15106-4 First edition 2008-06-01 Plastics Film and sheeting Determination of water vapour transmission rate Part 4: Gas-chromatographic detection sensor method Plastiques Film

More information

Remote. control unit. accessories. Leak detector SmartTest. Remote control unit for SmartTest. Remote. Vacuum analysis and measurement

Remote. control unit. accessories. Leak detector SmartTest. Remote control unit for SmartTest. Remote. Vacuum analysis and measurement Vacuum analysis and measurement Leak detector SmartTest Remote control unit Remote control unit for SmartTest Remote control unit Rugged and reliable Easy operation Clear and unambiguous display Integrated

More information

Chemical Thermo-con. How to Order. Communication A RS-485 B RS-232C. Power supply 2 Single-phase: 180 to 242 VAC 50/60 Hz.

Chemical Thermo-con. How to Order. Communication A RS-485 B RS-232C. Power supply 2 Single-phase: 180 to 242 VAC 50/60 Hz. Chemical Thermo-con Series HED How to Order Part number of set (Temperature controller + Heat exchanger) Note) The name plate on the Chemical Thermo-con shows the model numbers of the controller and heat

More information

Sub psi SPECIFICATIONS

Sub psi SPECIFICATIONS SPECIFICATIONS PC Board Mountable Pressure Sensor 40 mv Output Typical Differential Pressures Metal Tube and Ceramic Barbed Ports Temperature Compensated The 1210 sub PSI is a temperature compensated,

More information

Instruction manual. Carlin Combustion Technology, Inc. 70 Maple Street East Longmeadow, MA Ph Fx

Instruction manual. Carlin Combustion Technology, Inc. 70 Maple Street East Longmeadow, MA Ph Fx Instruction manual Applies to air intake assemblies: 97406 on EZ-1 burners 97406C on EZ-LF burners 97406A or 97406B on EZ-Gas burners Installation also requires a Field Controls Model CAS 1 air hood and

More information

Powers TM Controls Accessories for Installing TH 192, TH 194 or Free Energy Band TH 193 HC Room Thermostats

Powers TM Controls Accessories for Installing TH 192, TH 194 or Free Energy Band TH 193 HC Room Thermostats Powers TM Controls Accessories for Installing TH 192, TH 194 or Free Energy Band TH 193 HC Room Thermostats Technical Bulletin Document No. 155-244P25 TB 237 Rev. 2, December, 2001 Purpose This technical

More information

89BSD Digital Output

89BSD Digital Output SPECIFICATIONS Stainless Steel with O-Ring Seal Pressure/Temperature Read-Out (24-bit DS ADC) ASIC Calibrated Absolute, Sealed Gage 9mm Diameter The 89BSD is a 9mm diameter small profile, media compatible,

More information

VD 53 - Vacuum drying oven for non-flammable solvents

VD 53 - Vacuum drying oven for non-flammable solvents Vacuum drying ovens VD 53 - Vacuum drying oven for non-flammable solvents The VD series offers safe drying with homogenous temperature distribution, thanks to its APT.line air jacket system. ptimum heat

More information

Hitachi Tabletop Microscope TM4000 / TM4000 Plus

Hitachi Tabletop Microscope TM4000 / TM4000 Plus Hitachi Tabletop Microscope TM4000 / TM4000 Plus TM4000 Series Notice: For correct operation, follow the instruction manual when using the instrument. Specifications in this catalog are subject to change

More information

TS105-10L5.5MM Thermopile Sensor

TS105-10L5.5MM Thermopile Sensor SPECIFICATIONS Thermopile IR-Sensor For Contactless Temperature Measurement Single Element For Industrial Pyrometers Silicon Lens Accurate Reference Sensor Thermopiles are mainly used for contactless temperature

More information

Solar-Powered BLE Sensor Beacon 5 Pack Kit Guide

Solar-Powered BLE Sensor Beacon 5 Pack Kit Guide CYALKIT-E03 Solar-Powered BLE Sensor Beacon 5 Pack Kit Guide Doc. No. 002-12543 Rev. ** Cypress Semiconductor 198 Champion Court San Jose, CA 95134-1709 Phone (USA): 800.858.1810 Phone (Intl): 408.943.2600

More information

Battery charger modules

Battery charger modules Battery charger modules D8132 and D8132LT en Installation manual Battery charger modules Notices en 3 1 Notices These instructions cover the installation of the D8132 Battery Charger and the D8132LT Battery

More information

LASER DIODE NX7637BF-AA

LASER DIODE NX7637BF-AA 1 625 nm InGaAsP MQW-FP LASER DIODE COAXIAL MODULE FOR OTDR APPLICATION LASER DIODE NX7637BF-AA DESCRIPTION The NX7637BF-AA is a 1 625 nm Multiple Quantum Well (MQW) structured Fabry-Perot (FP) laser diode

More information

owners manual mara washlounge #1408 MARA comfortel.com.au

owners manual mara washlounge #1408 MARA comfortel.com.au owners manual mara washlounge #1408 MARA comfortel.com.au GET STARTED MARA Reclining backrest washlounge with footrest. Optional basin colour of black or white. Width: 530mm Length: 1350mm Basin Height:

More information

OVEN INDUSTRIES, INC.

OVEN INDUSTRIES, INC. OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-252 TEMPERATURE CONTROLLER With PLC Inputs Introduction Thank you for purchasing our controller. The Model 5C7-252 is an exceptionally versatile unit and

More information

Owner s Manual. Filterless UV Air Purifier. This Manual Includes:

Owner s Manual. Filterless UV Air Purifier. This Manual Includes: Filterless UV Air Purifier Item No. 203758 Owner s Manual This Manual Includes: Warranty Safety Warnings Operating Instructions Replacement Directions Troubleshooting Tips Cleaning and Maintenance Tips

More information

Panel Remote Annunciators Installation Instructions

Panel Remote Annunciators Installation Instructions Panel Remote Annunciators Installation Instructions Introduction This publication describes the installation procedures for the following PIDs: 4100-9607 Remote Annunciator w/ Flexible User Interface Domestic

More information

Installation Manual September Opticom Infrared System. Model 798 Emitter Bezel Mount Kit

Installation Manual September Opticom Infrared System. Model 798 Emitter Bezel Mount Kit Installation Manual September 2009 Opticom Infrared System Model 798 Emitter Bezel Mount Kit Installation i Table of Contents 1 About This Manual... 1 1.1 Purpose of Manual... 1 1.2 Manual Conventions...

More information