REFRIGERANT PIPING (LINE SET) CONDENSATE DRAIN PIPING SIDE WALL RETURN GRILLE AIR DEVICE TYPE AND SIZE SIDE WALL SUPPLY GRILLE CONNECT TO EXISTING

Size: px
Start display at page:

Download "REFRIGERANT PIPING (LINE SET) CONDENSATE DRAIN PIPING SIDE WALL RETURN GRILLE AIR DEVICE TYPE AND SIZE SIDE WALL SUPPLY GRILLE CONNECT TO EXISTING"

Transcription

1 VENTILATION RATE SUMMARY PER 0 NORTH CAROLINA BUILDING CODE, PRIVATE DWELLING SINGLE AND MULTIPLE LIVING AREAS - BEDROOMS UNIT NAME: UNIT B and B HC BEDROOM BEDROOM FLOOR AREA 5.00 SF OPERABLE WINDOW AREA.0 SF WINDOW TO FLOOR PERCENTAGE FOR BEDROOM 6% BEDROOM BEDROOM FLOOR AREA.00 SF OPERABLE WINDOW AREA.7 SF WINDOW TO FLOOR PERCENTAGE FOR BEDROOM % KITCHEN/LIVING ROOM KITCHEN/LIVING ROOM FLOOR AREA SF OPERABLE WINDOW AREA 56.7 SF WINDOW TO FLOOR PERCENTAGE % UNIT NAME: UNIT B BEDROOM BEDROOM FLOOR AREA 5.00 SF OPERABLE WINDOW AREA.7 SF WINDOW TO FLOOR PERCENTAGE FOR BEDROOM % BEDROOM BEDROOM FLOOR AREA 0.00 SF OPERABLE WINDOW AREA 9. SF WINDOW TO FLOOR PERCENTAGE FOR BEDROOM % KITCHEN/LIVING ROOM KITCHEN/LIVING ROOM FLOOR AREA 5.00 SF OPERABLE WINDOW AREA 5.9 SF WINDOW TO FLOOR PERCENTAGE 9% VENTILATION RATE SUMMARY PER 0 NORTH CAROLINA BUILDING CODE, PRIVATE DWELLING SINGLE AND MULTIPLE LIVING AREAS - BEDROOMS UNIT NAME: UNIT C and C HC BEDROOM BEDROOM FLOOR AREA 6.00 SF OPERABLE WINDOW AREA.7 SF WINDOW TO FLOOR PERCENTAGE FOR BEDROOM 9% BEDROOM BEDROOM FLOOR AREA 9.00 SF OPERABLE WINDOW AREA.7 SF WINDOW TO FLOOR PERCENTAGE FOR BEDROOM % BEDROOM BEDROOM FLOOR AREA 5.00 SF OPERABLE WINDOW AREA.7 SF WINDOW TO FLOOR PERCENTAGE FOR BEDROOM % KITCHEN/LIVING ROOM KITCHEN/LIVING ROOM FLOOR AREA SF OPERABLE WINDOW AREA 7. SF WINDOW TO FLOOR PERCENTAGE % VENTILATION RATE SUMMARY PER 0 NORTH CAROLINA BUILDING CODE, PRIVATE DWELLING SINGLE AND MULTIPLE LIVING AREAS - BEDROOM UNIT NAME: UNIT A and A HC BEDROOM BEDROOM FLOOR AREA 5.00 SF OPERABLE WINDOW AREA.7 SF WINDOW TO FLOOR PERCENTAGE FOR BEDROOM % KITCHEN/LIVING ROOM KITCHEN/LIVING ROOM FLOOR AREA.00 SF OPERABLE WINDOW AREA 7. SF WINDOW TO FLOOR PERCENTAGE 7% UNIT NAME: UNIT A BEDROOM BEDROOM FLOOR AREA.00 SF OPERABLE WINDOW AREA.7 SF WINDOW TO FLOOR PERCENTAGE FOR BEDROOM % KITCHEN/LIVING ROOM KITCHEN/LIVING ROOM FLOOR AREA SF OPERABLE WINDOW AREA 7. SF WINDOW TO FLOOR PERCENTAGE 0% UNIT NAME: UNIT A BEDROOM BEDROOM FLOOR AREA 5.00 SF OPERABLE WINDOW AREA.7 SF WINDOW TO FLOOR PERCENTAGE FOR BEDROOM 9% KITCHEN/LIVING ROOM KITCHEN/LIVING ROOM FLOOR AREA SF OPERABLE WINDOW AREA 7. SF WINDOW TO FLOOR PERCENTAGE % GENERAL NOTES. IN PREPARATION OF THESE PLANS, THE ENGINEER HAS USED CERTAIN ABBREVIATIONS, CONVENTIONS, AND SYMBOLS, THE MEANING OF WHICH ARE ILLUSTRATED AND EXPLAINED WITHIN THE LEGEND.. PLANS ARE DIAGRAMMATIC ONLY. THEY ARE INTENDED TO INDICATE CAPACITY, SIZE, LOCATION, DIRECTION, AND GENERAL ARRANGEMENT, BUT NOT EXACT DETAILS OF CONSTRUCTION. THE FACT THAT ONLY CERTAIN FEATURES OF THE INSTALLATION ARE INDICATED MUST NOT BE TAKEN TO MEAN THAT OTHER FEATURES WILL NOT BE REQUIRED.. COOINATE WITH THE OTHER TRADES TO INSURE THAT EACH TRADE SHALL HAVE SUFFICIENT SPACE TO INSTALL THEIR EQUIPMENT (DUCTWORK, PIPING, ELECTRICAL WORK, ETC.).. IN GENERAL, ALL PIPING AND DUCTWORK SHALL BE RUN IN THE CEILING SPACE UNLESS NOTED OR INDICATED OTHERWISE. A BTUH ABBREVIATIONS AFF AHU BHP CFM CLG CD AMPERES ABOVE FINISHED FLOOR AIR HANDLING UNIT BRAKE HORSEPOWER BRITISH THERMAL UNIT PER HOUR CUBIC FEET PER MINUTE CEILING CONDENSATE DRAIN SYMBOLS LEGEND DUCT FD WALL CEILING SUPPLY DIFFUSER CEILING RETURN GRILLE CEILING EXHAUST GRILLE CEILING EXHAUST FAN IN-LINE EXHAUST FAN DYNAMIC FIRE DAMPER STYLE 'B' FIRE DAMPER STYLE 'CR' FIRE DAMPER FOR ROUND DUCTS 5. VERIFY ALL DIMENSIONS FROM ARCHITECTURAL PLANS AND FIELD DIMENSIONS. 6. DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. 7. ALL RISES AND DROPS IN PIPING AND DUCTWORK MAY NOT NECESSARILY HAVE BEEN SHOWN. CONTRACTOR TO VERIFY.. PROVIDE ALL STRUCTURAL MEMBERS, SUPPORT BRACKETS, FLASHING, HAWARE, ETC. REQUIRED TO INSTALL A COMPLETE SYSTEM. 9. DIFFUSERS AND REGISTER LOCATIONS SHALL BE COOINATED WITH LIGHT FIXTURE AND OTHER CEILING DEVICE LOCATIONS. FIELD VERIFY. 0. MOUNT ALL CONTROLS ON THERMOSTATS AND/OR SENSORS FEET ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED. CU DB DN DX DIRECT EXPANSION EA EAT EF EL EXH CONDENSING UNIT DRY BULB DOWN EXHAUST AIR ENTERING AIR TEMPERATURE EXHAUST FAN ELEVATION EXHAUST DUCT DUCT SD FSD SD WALL WALL DYNAMIC SMOKE DAMPER COMBINATION DYNAMIC FIRE/SMOKE DAMPER DUCT SMOKE DETECTOR RETURN/EXHAUST DUCT TURNING DOWN RETURN/EXHAUST DUCT TURNING UP SUPPLY DUCT TURNING DOWN. CONNECTION IS DUCT SYSTEM MUST BE SEALED WITH MASTIC AND FIBERGLASS MESH.. ALL OPENINGS IN DUCT WORK AT REGISTERS AND GRILLS MUST BE COVERED AFTER INSTALLATION TO KEEP OUT DEBRIS DURING CONSTRUCTION.. FRESH AIR RETURNS MUST BE A MIN. " ABOVE THE FLOOR.. SUPPLY DUCTS IN UNCONDITIONED ATTICS MUST BE INSULATED WITH AN R- OR GREATER VALUE. EQUIP ESP FB FD FLEX FLR OR FL EQUIPMENT EXTERNAL STATIC PRESSURE FILTER BOX FIRE DAMPER FLEXIBLE FLOOR UC SUPPLY DUCT TURNING UP EXISTING DUCT TRANSFER OPENING IN WALL ABOVE CEILING /'' UNDERCUT BELOW DOOR RADIANT DAMPER () SYSTEMS, SERVICE AND EQUIPMENT FPI FPM FINS PER INCH CONNECT TO EXISTING FEET PER MINUTE METHOD OF COMPLIANCE: GALV GALVANIZED SIDE WALL SUPPLY GRILLE Prescriptive Performance Energy Cost Budget Climate Zone Thermal Zone winter dry bulb summer dry bulb Interior design conditions winter dry bulb summer dry bulb relative humidity Building heating load Building cooling load A NA NA HP KW LBS POUNDS MAX MBH KILOWATT MAXIMUM THOUSAND BTU/H MIN MINIMUM OA HORSEPOWER OUTSIDE AIR A-x 00 CFM T R SIDE WALL RETURN GRILLE AIR DEVICE TYPE AND SIZE AIR FLOW CFM THERMOSTAT REFRIGERANT PIPING (LINE SET) Mechanical Space Conditioning System Unitary description of unit heating efficiency cooling efficiency heat output of unit cooling output of unit Boiler total boiler output. If over sized, state reason. total chiller capacity. If over sized, state reason. Chiller List equipment efficiencies Equipment schedules with motors (mechanical systems) motor horsepower number of phases minimum efficiency motor type # of poles SEE MECH SCHEDULES SEE MECH SCHEDULES SEE MECH SCHEDULES SEE MECH SCHEDULES SEE MECH SCHEDULES NA NA NA SEE MECH SCHEDULES SEE MECH SCHEDULES SEE MECH SCHEDULES SEE MECH SCHEDULES SEE MECH SCHEDULES RA RTU SA TEMP TYP UC VD V WB ø RETURN AIR AND/OR ROOM AIR ROOFTOP UNIT SUPPLY AIR TEMPERATURE TYPICAL UNDERCUT MANUAL VOLUME DAMPER VOLTS WET BULB ROUND OBD OPPOSED BLADE DAMPER C CONDENSATE DRAIN PIPING PIPE TURNING UP PIPE TURNING DOWN M POSITION MOTORIZED DAMPER MANUAL VOLUME DAMPER GENERAL SYMBOLS SQFT SQUARE FEET PLAN OR DETAIL NO. TAD TRANSFER AIR DUCT SHEET NUMBER KEYED NOTE TO PLAN REVISION NUMBER NORTH ARROW N APARTMENT UNIT CONTROLS SEQUENCE:. EACH AIR CONDITIONING SYSTEM SHALL BE CONTROLLED BY A DIGITAL PROGRAMMABLE THERMOSTAT TO MAINTAIN A ROOM SET POINT TO BE SET BY TENANT. AMENITY HVAC CONTROLS SEQUENCE:. THE AIR HANDLER SHALL OPERATE DURING OCCUPIED HOURS. THE RESPECTIVE HEAT UNIT SHALL CYCLE ON/OFF BY A PROGRAMMABLE THERMOSTAT TO MAINTAIN A ROOM SET POINT (COOLING) 7ºF, (HEATING) 70ºF.. DURING UNOCCUPIED TIMES, THE AIR HANDLER MAY BE OVERRIDDEN THROUGH THE PROGRAMMABLE THERMOSTAT.. THE TWO POSITION MOTORIZED DAMPER IN THE OUTDOOR AIR DUCT SHALL BE ENERGIZED BY THE AIR HANDLER FAN THAT IT SERVES. FAN ENERGIZED, DAMPER SHALL BE OPEN, FAN DE-ENERGIZED, DAMPER SHALL CLOSE. DAMPER SHALL FAIL OPEN. 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 Revision Date NOTES & LEGENDS 5-00 December 0, 05 M00 /9/05 5:: PM C:\Users\aaguilar\\ _aaguilar.rvt

2 0 NORTH CAROLINA CODE - VENTILATION CALCULATION Amenity SPACE NAME AHU-A AREA (SF) OCCUPANCY CLASSIFICATION DEFAULT OCCUPANCY (QTY/000 SF) CALCULATED OCCUPANCY (PEOPLE) PEOPLE COUNT (LOAD) PEOPLE COUNT (VENT.) Rp VENT. RATE (CFM / P) Vbzp (CFM) Ra VENT. RATE (CFM / SF) Vbza (CFM) Vbz BREATHING ZONE OUTDOOR AIRFLOW (CFM) Corridor,97 Corridors AHU-A gym 75 Heath club/weight room Corridor,00 Corridors Storage 5 Storage, pick up AHU-A Asst Manager 0 Office spaces Corridor 79 Corridors Files/Package 0 Storage, pick up Gathering 660 Lobbies/prefunction Leasing 0 Office spaces Maintenance Office 506 Office spaces AHU-A Multi purpose,0 Multiuse assembly AHU-5A Indoor Sitting,500 Lobbies AHU-6A thru 9A Corridor,97 Corridors AHU-0A AIR DISTRIBUTION CONFIGURATION Ez ZONE AIR DISTRIBUTION EFFECTIVENESS Voz ZONE OUTDOOR AIRFLOW (CFM) Vpz ZONE SUPPLY AIRFLOW (CFM) Zp PRIMARY OUTDOOR AIR FRACTION Vou UNCORRECTED VENTILATION REQUIREMENT (CFM) Ceilling or floor supply of cool air Ceilling or floor supply of cool air Ceilling or floor supply of cool air Ceilling or floor supply of cool air Ceilling or floor supply of cool air Ceilling or floor supply of cool air 5 5 Ceilling or floor supply of cool air 5 5 Ceilling or floor supply of cool air Ceilling or floor supply of cool air 9 9 Ceilling or floor supply of cool air 5 5 Ceilling or floor supply of cool air Ceilling or floor supply of cool air Ceilling or floor supply of cool air Ceilling or floor supply Multi purpose 565 Multiuse assembly of cool air TOTAL EXHAUST RATE (CFM) 70 MAX Zp = Ev = SYSTEM OUTDOOR AIRFLOW = 90 TOTAL EXH. RATE PLUS 0% FOR PRESSURIZATION = 77 FINAL VENT. AIR REQUIREMENT (Greater of Above) = 90 NOTES:. COMPARISON OF THE TOTAL EXHAUST TO THE TOTAL VENTILATION IS TO ENSURE THAT THE VENTILATION AIR IS A MINIMUM OF 0% GREATER THAN THE EXHAUST AIR.. ASSUME 75 CFM EXFILTRATION PER '-0" DOOR. EXHAUST SUPPLEMENT IS TO ELIMINATE USAGE OF BAROMETRIC LOUVER FOR OVER-PRESSURIZATION. 9 R.G. Skinner Parkway Eng. of Record: License No.: 0 West Morehead Street, Suite 0 T: F: c 05 NOTES & LEGENDS 5-00 December 0, 05 M00 /9/05 5:: PM C:\Users\aaguilar\\ _aaguilar.rvt

3 ELEC 5 HP-5A AHU-5A STAIR A 50 UH- "x" "x" MECH. 5 RISER 5 UH- C-X 00 CFM C-X 00 CFM C-X 95 CFM INDOOR SITTING AREA C-X 90 CFM C-X 90 CFM C-X 90 CFM A-X6 5 CFM CORR 0 B-X A-X6 5 CFM MULTI-PURPOSE ROOM 5A MULTI-PURPOSE ROOM 5B B-0X0 "x" LOUNGE SF C-X 95 CFM C-X 90 CFM MAIL EF-5 WOMEN 0 HVAC 07A AHU-A CORR 0 "x0" C-X 00 CFM C-X 0 CFM LEASING 0 C-X 0 CFM WORK ROOM 06 "ø C-X 0 CFM AHU-A C-X 0 CFM WAITING 0 ENTRY 00 C-X A-X6 C-X 5 CFM C-X 5 CFM B-X B-X 0"ø C-X PROP. MGR 0 MEN EF- AHU-A HVAC 9 "x" B-0X TENANT STO. ELEV 90 CORR. 0 CORR. 0 "ø A-X6 UNIT A-HC 0 0"ø C-X 5 CFM C-X 5 CFM GYM 09 C-X 5 CFM C-X 5 CFM "x" 6"x" "x" "x" "x" C-X 00 CFM "x" "x" A-X6 00 CFM C-X 00 CFM 6"ø B-0X C-X 00 CFM B-X B-X 0"ø B-X B-X 0"ø A-X6 0 CFM 6"ø A-X6 0"ø 0"ø 0"ø 0"x" M0a "ø BUILDING A. - FIRST FLOOR PLAN - AREA A - MECHCANICAL SCALE: /" = '-0" PROVIDE WALL CAP; PAINT TO MATCH EXTERIOR. ALL CAPS ARE TO BE HORIZONTALLY AND VERTICALLY ALIGNED ON ALL BUILDING FACADES. OUTSIDE AIR DUCT FROM WALL CAP DOWN TO RETURN PLENUM ON BOTTOM OF AHU. PROVIDE MOTORIZED DAMPER ON DUCT NEAR PLENUM; INSULATE DUCT. PROVIDE RADIANT DAMPER AS DUCT GOES THRU FIRE RATED CEILING. DUCTWORK FROM AHU UP INTO STRUCTURE. PROVIDE A RADIANT DAMPER AT CEILING PENETRATION AND ACCESS PANEL IN DUCT. CLOSET. 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 BUILDING A. - FIRST FLOOR PLAN - AREA A - December 0, 05 M0a 5-00 /9/05 5::6 PM C:\Users\aaguilar\\ _aaguilar.rvt

4 M0b HP-7A HP-9A HP- HP- HP- HP- HP- HP- HP- HP- HP- HP- HP- HP- HP- HP-A HP- HP- HP- HP- HP- HP- HP- HP- HP- HP- HP- HP-A HP- HP- HP- HP- HP- HP- HP- HP- HP- HP- HP- HP- HP- HP- HP- HP- HP- HP- HP-A HP- HP- HP- HP- HP- HP- HP- HP- HP- HP- HP- HP- HP- UNIT A_M 9 UNIT A_M 7 UNIT A_M 5 UNIT A_M UNIT A UNIT A-HC 6"ø A-X6 "x0" A-X6 6"ø A-X6 A-X6 0 CFM A-X6 " ø 5 CFM " ø UNIT A_M 0 UNIT A_M UNIT A_M 6 UNIT A_M BUILDING A. - FIRST FLOOR PLAN - AREA B - MECHCANICAL SCALE: /" = '-0" LOCATE HEAP PUMPS ON GRADE AND ROUTE REFRIGERANT LINES IN EXTERIOR WALL AND OVER TO RESPETIVE AIR HANDLER. TOUTE REFRIGERANT LINES TO UPPER LEVELS WITHIN THE CLOSET. 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 BUILDING A. - FIRST FLOOR PLAN - AREA B - December 0, 05 M0b 5-00 /9/05 5::0 PM C:\Users\aaguilar\\ _aaguilar.rvt

5 HP-6A HP-A HP- HP- HP- DRYER VENT CALC: 5 FT + 90 ELBOW + 5 ELBOW =.5 FT. 5 HP- HP- HP- HP-A HP- HP- UH- A-X6 00 CFM STAIR B 60 SERVICE 6 - LAUNDRY 6A CORR 05 HVAC 6 AHU-A A-0X 6"x0" M0c A-X6 A-X6 B-0X "x0" COVERED PATIO 65 BUILDING A. - FIRST FLOOR PLAN - AREA C - MECHCANICAL SCALE: /" = '-0" 5 PROVIDE WALL CAP; PAINT TO MATCH EXTERIOR. ALL CAPS ARE TO BE HORIZONTALLY AND VERTICALLY ALIGNED ON ALL BUILDING FACADES. OUTSIDE AIR DUCT FROM WALL CAP DOWN TO RETURN PLENUM ON BOTTOM OF AHU. PROVIDE MOTORIZED DAMPER ON DUCT NEAR PLENUM; INSULATE DUCT. PROVIDE RADIANT DAMPER AS DUCT GOES THRU FIRE RATED CEILING. DUCTWORK FROM AHU UP INTO STRUCTURE. PROVIDE A RADIANT DAMPER AT CEILING PENETRATION AND ACCESS PANEL IN DUCT. CLOSET. LOCATE HEAT PUMPS ON GRADE AND ROUTE REFRIGERANT LINES IN EXTERIOR WALL AND OVER TO RESPECTIVE AIR HANDLER. ROUTE REFRIGERANT LINES TO UPPER LEVELS WITHIN THE CLOSET. 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 BUILDING A. - FIRST FLOOR PLAN - AREA C - December 0, 05 M0c 5-00 /9/05 5:: PM C:\Users\aaguilar\\ _aaguilar.rvt

6 A-X6 A-X6 A-X6 5 CFM AHU-7A "x" A-X6 00 CFM 0"x0" "ø EF- A-X6 00 CFM B-0X 0"ø A-X6 00 CFM 0"ø A-X6 OA DUCT UP TO ABOVE M0a 0"ø A-X6 BUILDING A. - SECOND FLOOR PLAN - AREA A - MECHCANICAL SCALE: /" = '-0" PROVIDE WALL CAP; PAINT TO MATCH EXTERIOR. ALL CAPS ARE TO BE HORIZONTALLY AND VERTICALLY ALIGNED ON ALL BUILDING FACADES. OUTSIDE AIR DUCT FROM WALL CAP DOWN TO RETURN PLENUM ON BOTTOM OF AHU. PROVIDE MOTORIZED DAMPER ON DUCT NEAR PLENUM; INSULATE DUCT. PROVIDE RADIANT DAMPER AS DUCT GOES THRU FIRE RATED CEILING. DUCTWORK FROM AHU UP INTO STRUCTURE. PROVIDE A RADIANT DAMPER AT CEILING PENETRATION AND ACCESS PANEL IN DUCT. CLOSET. 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 BUILDING A. - SECOND FLOOR PLAN - AREA A - December 0, 05 M0a 5-00 /9/05 5::5 PM C:\Users\aaguilar\\ _aaguilar.rvt

7 A-X6 A-X6 A-X6 A-X6 5 CFM M0b "x0" BUILDING A. - SECOND FLOOR PLAN - AREA B - MECHCANICAL SCALE: /" = '-0" A-X6 00 CFM 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 BUILDING A. - SECOND FLOOR PLAN - AREA B - December 0, 05 M0b 5-00 /9/05 5:: PM C:\Users\aaguilar\\ _aaguilar.rvt

8 DRYER VENT CALC: 5 FT + 90 ELBOW + 5 ELBOW =.5 FT. A-X6 AHU-6A A-X6 00 CFM B-0X 0"x" 5"ø 6"x" M0c A-0X BUILDING A. - SECOND FLOOR PLAN - AREA C - MECHCANICAL SCALE: /" = '-0" PROVIDE WALL CAP; PAINT TO MATCH EXTERIOR. ALL CAPS ARE TO BE HORIZONTALLY AND VERTICALLY ALIGNED ON ALL BUILDING FACADES. OUTSIDE AIR DUCT FROM WALL CAP DOWN TO RETURN PLENUM ON BOTTOM OF AHU. PROVIDE MOTORIZED DAMPER ON DUCT NEAR PLENUM; INSULATE DUCT. PROVIDE RADIANT DAMPER AS DUCT GOES THRU FIRE RATED CEILING. DUCTWORK FROM AHU UP INTO STRUCTURE. PROVIDE A RADIANT DAMPER AT CEILING PENETRATION AND ACCESS PANEL IN DUCT. CLOSET. 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 BUILDING A. - SECOND FLOOR PLAN - AREA C - December 0, 05 M0c 5-00 /9/05 5::5 PM C:\Users\aaguilar\\ _aaguilar.rvt

9 6"ø AHU-9A "x" EF- 0"ø OA DUCT UP TO ABOVE 0"x0" "ø "ø 0"ø A-X6 00 CFM M0a A-X6 A-X6 A-X6 00 CFM A-X6 5 CFM A-X6 00 CFM B-0X A-X6 0"ø BUILDING A. - THI FLOOR PLAN - AREA A - MECHCANICAL SCALE: /" = '-0" PROVIDE WALL CAP; PAINT TO MATCH EXTERIOR. ALL CAPS ARE TO BE HORIZONTALLY AND VERTICALLY ALIGNED ON ALL BUILDING FACADES. OUTSIDE AIR DUCT FROM WALL CAP DOWN TO RETURN PLENUM ON BOTTOM OF AHU. PROVIDE MOTORIZED DAMPER ON DUCT NEAR PLENUM; INSULATE DUCT. PROVIDE RADIANT DAMPER AS DUCT GOES THRU FIRE RATED CEILING. DUCTWORK FROM AHU UP INTO STRUCTURE. PROVIDE A RADIANT DAMPER AT CEILING PENETRATION AND ACCESS PANEL IN DUCT. CLOSET. 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 BUILDING A. - THI FLOOR PLAN - AREA A - December 0, 05 M0a 5-00 /9/05 5::05 PM C:\Users\aaguilar\\ _aaguilar.rvt

10 "x0" A-X6 A-X6 M0b A-X6 BUILDING A. - THI FLOOR PLAN - AREA B - MECHCANICAL SCALE: /" = '-0" A-X6 5 CFM A-X6 00 CFM 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 BUILDING A. - THI FLOOR PLAN - AREA B - December 0, 05 M0b 5-00 /9/05 5:: PM C:\Users\aaguilar\\ _aaguilar.rvt

11 DRYER VENT CALC: 5 FT + 90 ELBOW + 5 ELBOW =.5 FT. AHU-A 6"x" 5"ø M0c A-0X A-X6 BUILDING A. - THI FLOOR PLAN - AREA C - MECHCANICAL SCALE: /" = '-0" A-X6 00 CFM A-X6 0"x" B-0X PROVIDE WALL CAP; PAINT TO MATCH EXTERIOR. ALL CAPS ARE TO BE HORIZONTALLY AND VERTICALLY ALIGNED ON ALL BUILDING FACADES. OUTSIDE AIR DUCT FROM WALL CAP DOWN TO RETURN PLENUM ON BOTTOM OF AHU. PROVIDE MOTORIZED DAMPER ON DUCT NEAR PLENUM; INSULATE DUCT. PROVIDE RADIANT DAMPER AS DUCT GOES THRU FIRE RATED CEILING. DUCTWORK FROM AHU UP INTO STRUCTURE. PROVIDE A RADIANT DAMPER AT CEILING PENETRATION AND ACCESS PANEL IN DUCT. CLOSET. 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 BUILDING A. - THI FLOOR PLAN - AREA C - December 0, 05 M0c 5-00 /9/05 5::6 PM C:\Users\aaguilar\\ _aaguilar.rvt

12 M0a BUILDING A. - ROOF PLAN - AREA A - MECHCANICAL SCALE: /" = '-0" OUTSIDE AIR DUCT FROM BELOW. TERMINATE AT A GREENHECK ROOF CAP WITH INSULATED CURB AND INSECT SCREEN. 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 BUILDING A. - ROOF PLAN - AREA A - December 0, 05 M0a 5-00 /9/05 5::9 PM C:\Users\aaguilar\\ _aaguilar.rvt

13 M UP UP UP UP UP UNIT C 5 UNIT B 6 UNIT B 7 UNIT B UNIT C 9 HP-5 HP- HP- HP- HP-5 BUILDING B. - FIRST FLOOR PLAN - SCALE: /" = '-0" LOCATE HEAP PUMPS ON GRADE AND ROUTE REFRIGERANT LINES IN EXTERIOR WALL AND OVER TO RESPETIVE AIR HANDLER. TOUTE REFRIGERANT LINES TO UPPER LEVELS WITHIN THE CLOSET. 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 BUILDING B. - FIRST FLOOR PLAN December 0, 05 M /9/05 5::5 PM C:\Users\aaguilar\\ _aaguilar.rvt

14 M UP UP UNIT B UNIT B UNIT C HP- BUILDING B. - FIRST FLOOR PLAN - SCALE: /" = '-0" HP- LOCATE HEAP PUMPS ON GRADE AND ROUTE REFRIGERANT LINES IN EXTERIOR WALL AND OVER TO RESPETIVE AIR HANDLER. TOUTE REFRIGERANT LINES TO UPPER LEVELS WITHIN THE CLOSET. UP HP-5 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 BUILDING B. - FIRST FLOOR PLAN December 0, 05 M /9/05 5::56 PM C:\Users\aaguilar\\ _aaguilar.rvt

15 M UP UP UNIT C 9 UNIT B 0 HP- HP-5 BUILDING B. - FIRST FLOOR PLAN - SCALE: /" = '-0" UP UP UP UP UNIT B UNIT B UNIT C HP- HP- HP- HP-5 LOCATE HEAP PUMPS ON GRADE AND ROUTE REFRIGERANT LINES IN EXTERIOR WALL AND OVER TO RESPETIVE AIR HANDLER. TOUTE REFRIGERANT LINES TO UPPER LEVELS WITHIN THE CLOSET. 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 BUILDING B. - FIRST FLOOR PLAN December 0, 05 M /9/05 5::0 PM C:\Users\aaguilar\\ _aaguilar.rvt

16 M5 UP UP UNIT C 5 UNIT C 6 HP- HP- HP-5 BUILDING B. - FIRST FLOOR PLAN - SCALE: /" = '-0" LOCATE HEAP PUMPS ON GRADE AND ROUTE REFRIGERANT LINES IN EXTERIOR WALL AND OVER TO RESPETIVE AIR HANDLER. TOUTE REFRIGERANT LINES TO UPPER LEVELS WITHIN THE CLOSET. UP HP- UP UP UP UNIT B 9 UNIT B 50 HP- HP-5 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 BUILDING B. - FIRST FLOOR PLAN December 0, 05 M5 /9/05 5::05 PM C:\Users\aaguilar\\ _aaguilar.rvt

17 HP- HP- HP- HP- HP- HP- HP- HP- C-X 75 CFM C-X 75 CFM AHU-0A B-0X EF- C-X MULTI-PURPOSE ROOM EF- 00 C-X 75 CFM C-X CORR 000 UNIT A-M 0 UNIT A M-HC 0 UNIT A-HC 05 HP- HP-0A C-X 75 CFM B-0X "x" CORR 00 "x" M6 5 PROVIDE WALL CAP; PAINT TO MATCH EXTERIOR. ALL CAPS ARE TO BE HORIZONTALLY AND VERTICALLY ALIGNED ON ALL BUILDING FACADES. OUTSIDE AIR DUCT FROM WALL CAP DOWN TO RETURN PLENUM ON BOTTOM OF AHU. PROVIDE MOTORIZED DAMPER ON DUCT NEAR PLENUM; INSULATE DUCT. PROVIDE RADIANT DAMPER AS DUCT GOES THRU FIRE RATED CEILING. HP- HP- DUCTWORK FROM AHU UP INTO STRUCTURE. PROVIDE A RADIANT DAMPER AT CEILING PENETRATION AND ACCESS PANEL IN DUCT. HP- HP- HP- HP- HP- HP- 5 UNIT A-HC 06 5 CLOSET. LOCATE HEAT PUMPS ON GRADE AND ROUTE REFRIGERANT LINES IN EXTERIOR WALL AND OVER TO RESPECTIVE AIR HANDLER. ROUTE REFRIGERANT LINES TO UPPER LEVELS WITHIN THE CLOSET. HP- HP- UNIT A-M 0 UNIT A M-HC 0 HP- HP- HP- HP- BUILDING C. - FIRST FLOOR PLAN - SCALE: /" = '-0" 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 BUILDING C. - FIRST FLOOR PLAN December 0, 05 M6 /9/05 5::0 PM C:\Users\aaguilar\\ _aaguilar.rvt

18 M7 HP-5 HP- HP- UP UP BUILDING D. - FIRST FLOOR PLAN - SCALE: /" = '-0" HP- HP- UP UP UP LOCATE HEAP PUMPS ON GRADE AND ROUTE REFRIGERANT LINES IN EXTERIOR WALL AND OVER TO RESPETIVE AIR HANDLER. TOUTE REFRIGERANT LINES TO UPPER LEVELS WITHIN THE CLOSET. HP- 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 BUILDING D. - FIRST FLOOR PLAN December 0, 05 M7 /9/05 5:: PM C:\Users\aaguilar\\ _aaguilar.rvt

19 M UNIT B 0 UP UNIT B 0 UP UNIT C-HC 0 HP- HP- BUILDING D. - FIRST FLOOR PLAN - SCALE: /" = '-0" LOCATE HEAP PUMPS ON GRADE AND ROUTE REFRIGERANT LINES IN EXTERIOR WALL AND OVER TO RESPETIVE AIR HANDLER. TOUTE REFRIGERANT LINES TO UPPER LEVELS WITHIN THE CLOSET. HP-5 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 BUILDING D. - FIRST FLOOR PLAN December 0, 05 M /9/05 5:: PM C:\Users\aaguilar\\ _aaguilar.rvt

20 BEDROOM 0 UNIT A 0 W.I.C. 06 AHU- T T A-X6 A-X6 UNIT A-HC BEDROOM W.I.C. 5 B-0X A-X6 KITCHEN 5 0"x0" 0"x" COAT 5 LINEN 5 A-0X AHU- BATH EF- PAN 55 A-X6 A-X LINEN 07 HVAC 0 0"x0" EF- A-0X KITCHEN 05 A-X6 BATH A-X6 A-X6 A-X6 A-X6 BEDROOM 65 UNIT A_M 09 A-X6 UNIT A_M 7 A-X6 BEDROOM 50 5 UNIT PLAN - A M - M0 SCALE: /" = '-0" UNIT PLAN - A HC - M0 SCALE: /" = '-0" UNIT PLAN - A M - M0 SCALE: /" = '-0" UNIT PLAN - A M - M0 SCALE: /" = '-0" UNIT A - M0 SCALE: /" = '-0" PROVIDE WALL CAP; PAINT TO MATCH EXTERIOR. ALL CAPS ARE TO BE HORIZONTALLY AND VERTICALLY ALIGNED ON ALL BUILDING FACADES. " DRYER DUCT. PROVIDE 6 GA. GALV. SHEET METAL DUCT. ROUTE DUCT IN SOFFIT PROVIDED, SEE ARCH PLANS FOR FURTHER DETAILING OF SOFFIT. VENT CONNECTION MUST BE " MAX. ABV. FIN. FLOOR. ENSURE PROPER ACCESS IN CLOSET TO THE RADIANT DAMPER IN THE SUPPLY DUCTWORK. PROVIDE FACTORY SUPPLIED RETURN/ACCESS PANEL FOR AHU WHERE INDICATED CLOSET. PROVIDE A PLENUM BOX FROM AHU UP TO TRUSS SPACE. CONTRACTOR TO COOINATE TRUSS LOCATIONS ABOVE AHU CLOSET TO ALLOW FOR DUCT PENETRATION. PROVIDE A RADIANT DAMPER AT CEILING PENETRATION. ALL BEDROOM DOORS SHALL BE UNDERCUT BY / INCH. PROVIDE A B-x0 RETURN GRILLE OVER THE DOOR TO THE WASHER/DRYER CLOSET. GRILLE SHALL PROVIDE 00 SQ. IN. FREE AREA. CONTRACTOR TO ENSURE ALL EXHAUST AND DRYER TERMINATIONS WILL HAVE A ' MINIMUM CLEARANCE TO OPERABLE WINDOW OPENINGS. MEASUREMENT IS TO THE TOP SASH OPENING FOR DOUBLE HUNG WINDOWS. PROVIDE A X MIN. RETURN GRILL OVER THE DOOR TO ALL BEDROOM CLOSETS, INTERIOR STORAGE ROOMS AND COAT CLOSETS. 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 UNIT PLAN - A December 0, 05 M0 /9/05 5:: PM C:\Users\aaguilar\\ _aaguilar.rvt

21 T T STOR 7 BEDROOM 7 A-X6 A-0X B-0X NOTE: NON-STACKED DRYER IS A GE MODEL GTXESS. A-X6 A-X6 UNIT A 7 W.I.C. 76 LAUNDRY 5 AHU "x0" LINEN HVAC 6 EF- BATH 7 A-0X B-0X A-X6 KITCHEN 75 PAN PROVIDE WALL CAP; PAINT TO MATCH EXTERIOR. ALL CAPS ARE TO BE HORIZONTALLY AND VERTICALLY ALIGNED ON ALL BUILDING FACADES. " DRYER DUCT. PROVIDE 6 GA. GALV. SHEET METAL DUCT. ROUTE DUCT IN SOFFIT PROVIDED, SEE ARCH PLANS FOR FURTHER DETAILING OF SOFFIT. VENT CONNECTION MUST BE " MAX. ABV. FIN. FLOOR. ENSURE PROPER ACCESS IN CLOSET TO THE RADIANT DAMPER IN THE SUPPLY DUCTWORK. PROVIDE FACTORY SUPPLIED RETURN/ACCESS PANEL FOR AHU WHERE INDICATED CLOSET. PROVIDE A PLENUM BOX FROM AHU UP TO TRUSS SPACE. CONTRACTOR TO COOINATE TRUSS LOCATIONS ABOVE AHU CLOSET TO ALLOW FOR DUCT PENETRATION. PROVIDE A RADIANT DAMPER AT CEILING PENETRATION. ALL BEDROOM DOORS SHALL BE UNDERCUT BY / INCH. PROVIDE A B-x0 RETURN GRILLE OVER THE DOOR TO THE WASHER/DRYER CLOSET. GRILLE SHALL PROVIDE 00 SQ. IN. FREE AREA. CONTRACTOR TO ENSURE ALL EXHAUST AND DRYER TERMINATIONS WILL HAVE A ' MINIMUM CLEARANCE TO OPERABLE WINDOW OPENINGS. MEASUREMENT IS TO THE TOP SASH OPENING FOR DOUBLE HUNG WINDOWS. PROVIDE A X MIN. RETURN GRILL OVER THE DOOR TO ALL BEDROOM CLOSETS, INTERIOR STORAGE ROOMS AND COAT CLOSETS. 0"x0" AHU- 5 6 EF- 7 A-X6 9 DRYER DUCT = 0 FEET LENGTH + 5 FEET FOR -90 DEGREE ELBOW AND.5 FEET FOR -5 DEGREE ELBOW = 7.5 EQUIVALENT FEET. UNIT A - M0 SCALE: /" = '-0" A-X6 DRYER DUCT = 0 FEET LENGTH + 5 FEET FOR -90 DEGREE ELBOW AND.5 FEET FOR -5 DEGREE ELBOW = 7.5 EQUIVALENT FEET. UNIT A - M0 SCALE: /" = '-0" 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 UNIT PLAN - A & A December 0, 05 M0 /9/05 5:: PM C:\Users\aaguilar\\ _aaguilar.rvt

22 PROVIDE WALL CAP; PAINT TO MATCH EXTERIOR. ALL CAPS ARE TO BE HORIZONTALLY AND VERTICALLY ALIGNED ON ALL BUILDING FACADES. " DRYER DUCT. PROVIDE 6 GA. GALV. SHEET METAL DUCT. ROUTE DUCT IN SOFFIT PROVIDED, SEE ARCH PLANS FOR FURTHER DETAILING OF SOFFIT. VENT CONNECTION MUST BE " MAX. ABV. FIN. FLOOR. ENSURE PROPER ACCESS IN CLOSET TO THE RADIANT DAMPER IN THE SUPPLY DUCTWORK. PROVIDE FACTORY SUPPLIED RETURN/ACCESS PANEL FOR AHU WHERE INDICATED NOTE: NON-STACKED DRYER IS A GE MODEL GTXESS. 5 6 CLOSET. PROVIDE A PLENUM BOX FROM AHU UP TO TRUSS SPACE. CONTRACTOR TO COOINATE TRUSS LOCATIONS ABOVE AHU CLOSET TO ALLOW FOR DUCT PENETRATION. PROVIDE A RADIANT DAMPER AT CEILING PENETRATION. 7 ALL BEDROOM DOORS SHALL BE UNDERCUT BY / INCH. PROVIDE A B-x0 RETURN GRILLE OVER THE DOOR TO THE WASHER/DRYER CLOSET. GRILLE SHALL PROVIDE 00 SQ. IN. FREE AREA. 9 CONTRACTOR TO ENSURE ALL EXHAUST AND DRYER TERMINATIONS WILL HAVE A ' MINIMUM CLEARANCE TO OPERABLE WINDOW OPENINGS. MEASUREMENT IS TO THE TOP SASH OPENING FOR DOUBLE HUNG WINDOWS. 0 PROVIDE A X MIN. RETURN GRILL OVER THE DOOR TO ALL BEDROOM CLOSETS, INTERIOR STORAGE ROOMS AND COAT CLOSETS. STOR 757 A-X6 A-X6 BEDROOM 75 UNIT A-HC W.I.C. 756 AHU- LAUNDRY 0 HVAC 09 LINEN 00 0"x0" T KITCHEN 755 0"x" BATH 75 A-0X B-0X A-X6 EF- PAN 0 DRYER DUCT = FEET LENGTH + 5 FEET FOR -90 DEGREE ELBOW AND.5 FEET FOR -5 DEGREE ELBOW = 5.5 EQUIVALENT FEET. UNIT A HC - M0 SCALE: /" = '-0" 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 UNIT PLAN - A HC December 0, 05 M0 /9/05 5:: PM C:\Users\aaguilar\\ _aaguilar.rvt

23 NOTE: NON-STACKED DRYER IS A GE MODEL GTXESS. STOR 099 A-X6 A-X6 BEDROOM 59 UNIT A-M 5 W.I.C. 6 AHU- 5 6 LAUNDRY T 0"x0" LINEN 096 0"x0" B-0X KITCHEN 6 EF- BATH 60 A-0X A-X6 DRYER DUCT = 0 FEET LENGTH + 5 FEET FOR -90 DEGREE ELBOW AND.5 FEET FOR -5 DEGREE ELBOW = 7.5 EQUIVALENT FEET. UNIT A M - M0 SCALE: /" = '-0" PROVIDE WALL CAP; PAINT TO MATCH EXTERIOR. ALL CAPS ARE TO BE HORIZONTALLY AND VERTICALLY ALIGNED ON ALL BUILDING FACADES. " DRYER DUCT. PROVIDE 6 GA. GALV. SHEET METAL DUCT. ROUTE DUCT IN SOFFIT PROVIDED, SEE ARCH PLANS FOR FURTHER DETAILING OF SOFFIT. VENT CONNECTION MUST BE " MAX. ABV. FIN. FLOOR. ENSURE PROPER ACCESS IN CLOSET TO THE RADIANT DAMPER IN THE SUPPLY DUCTWORK. PROVIDE FACTORY SUPPLIED RETURN/ACCESS PANEL FOR AHU WHERE INDICATED CLOSET. PROVIDE A PLENUM BOX FROM AHU UP TO TRUSS SPACE. CONTRACTOR TO COOINATE TRUSS LOCATIONS ABOVE AHU CLOSET TO ALLOW FOR DUCT PENETRATION. PROVIDE A RADIANT DAMPER AT CEILING PENETRATION. ALL BEDROOM DOORS SHALL BE UNDERCUT BY / INCH. PROVIDE A B-x0 RETURN GRILLE OVER THE DOOR TO THE WASHER/DRYER CLOSET. GRILLE SHALL PROVIDE 00 SQ. IN. FREE AREA. CONTRACTOR TO ENSURE ALL EXHAUST AND DRYER TERMINATIONS WILL HAVE A ' MINIMUM CLEARANCE TO OPERABLE WINDOW OPENINGS. MEASUREMENT IS TO THE TOP SASH OPENING FOR DOUBLE HUNG WINDOWS. PROVIDE A X MIN. RETURN GRILL OVER THE DOOR TO ALL BEDROOM CLOSETS, INTERIOR STORAGE ROOMS AND COAT CLOSETS. 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 UNIT PLAN - A M December 0, 05 M0 /9/05 5::6 PM C:\Users\aaguilar\\ _aaguilar.rvt

24 PROVIDE WALL CAP; PAINT TO MATCH EXTERIOR. ALL CAPS ARE TO BE HORIZONTALLY AND VERTICALLY ALIGNED ON ALL BUILDING FACADES. " DRYER DUCT. PROVIDE 6 GA. GALV. SHEET METAL DUCT. ROUTE DUCT IN SOFFIT PROVIDED, SEE ARCH PLANS FOR FURTHER DETAILING OF SOFFIT. VENT CONNECTION MUST BE " MAX. ABV. FIN. FLOOR. ENSURE PROPER ACCESS IN CLOSET TO THE RADIANT DAMPER IN THE SUPPLY DUCTWORK. PROVIDE FACTORY SUPPLIED RETURN/ACCESS PANEL FOR AHU WHERE INDICATED NOTE: NON-STACKED DRYER IS A GE MODEL GTXESS. 5 6 CLOSET. PROVIDE A PLENUM BOX FROM AHU UP TO TRUSS SPACE. CONTRACTOR TO COOINATE TRUSS LOCATIONS ABOVE AHU CLOSET TO ALLOW FOR DUCT PENETRATION. PROVIDE A RADIANT DAMPER AT CEILING PENETRATION. 7 ALL BEDROOM DOORS SHALL BE UNDERCUT BY / INCH. PROVIDE A B-x0 RETURN GRILLE OVER THE DOOR TO THE WASHER/DRYER CLOSET. GRILLE SHALL PROVIDE 00 SQ. IN. FREE AREA. 9 CONTRACTOR TO ENSURE ALL EXHAUST AND DRYER TERMINATIONS WILL HAVE A ' MINIMUM CLEARANCE TO OPERABLE WINDOW OPENINGS. MEASUREMENT IS TO THE TOP SASH OPENING FOR DOUBLE HUNG WINDOWS. 0 PROVIDE A X MIN. RETURN GRILL OVER THE DOOR TO ALL BEDROOM CLOSETS, INTERIOR STORAGE ROOMS AND COAT CLOSETS. STOR 6 A-X6 A-X6 BEDROOM 5 UNIT A M-HC T W.I.C. AHU- 5 6 LAUNDRY HVAC 5 0"x0" LINEN 5 0"x0" B-0X BATH 6 A-0X A-X6 KITCHEN 7 EF- PAN 5 DRYER DUCT = FEET LENGTH + 5 FEET FOR -90 DEGREE ELBOW AND.5 FEET FOR -5 DEGREE ELBOW = 5.5 EQUIVALENT FEET. UNIT A M HC - M05 SCALE: /" = '-0" 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 UNIT PLAN - A M HC December 0, 05 M05 /9/05 5::50 PM C:\Users\aaguilar\\ _aaguilar.rvt

25 SEE UNIT B- FOR LAYOUT A-X6 A-X6 A-X6 AHU- A-0X T T NOTE: NON-STACKED DRYER IS A GE MODEL GTXESS. PROVIDE WALL CAP; PAINT TO MATCH EXTERIOR. ALL CAPS ARE TO BE HORIZONTALLY AND VERTICALLY ALIGNED ON ALL BUILDING FACADES. " DRYER DUCT. PROVIDE 6 GA. GALV. SHEET METAL DUCT. ROUTE DUCT IN SOFFIT PROVIDED, SEE ARCH PLANS FOR FURTHER DETAILING OF SOFFIT. VENT CONNECTION MUST BE " MAX. ABV. FIN. FLOOR. ENSURE PROPER ACCESS IN CLOSET TO THE RADIANT DAMPER IN THE SUPPLY DUCTWORK. PROVIDE FACTORY SUPPLIED RETURN/ACCESS PANEL FOR AHU WHERE INDICATED 5 CLOSET. 6 PROVIDE A PLENUM BOX FROM AHU UP TO TRUSS SPACE. CONTRACTOR TO COOINATE TRUSS LOCATIONS ABOVE AHU CLOSET TO ALLOW FOR DUCT PENETRATION. PROVIDE A RADIANT DAMPER AT CEILING PENETRATION. 7 ALL BEDROOM DOORS SHALL BE UNDERCUT BY / INCH. PROVIDE A B-x0 RETURN GRILLE OVER THE DOOR TO THE WASHER/DRYER CLOSET. GRILLE SHALL PROVIDE 00 SQ. IN. FREE AREA. 9 CONTRACTOR TO ENSURE ALL EXHAUST AND DRYER TERMINATIONS WILL HAVE A ' MINIMUM CLEARANCE TO OPERABLE WINDOW OPENINGS. MEASUREMENT IS TO THE TOP SASH OPENING FOR DOUBLE HUNG WINDOWS. 0 PROVIDE A X MIN. RETURN GRILL OVER THE DOOR TO ALL BEDROOM CLOSETS, INTERIOR STORAGE ROOMS AND COAT CLOSETS. A-X6 A-X6 A-X "x0" "x0" "x0" B-0X A-X6 A-0X EF- EF- AHU- " ø A-0X B-0X A-0X A-X6 EF- EF- DRYER DUCT = FEET LENGTH + 5 FEET FOR -90 DEGREE ELBOW AND.5 FEET FOR -5 DEGREE ELBOW = 5.5 EQUIVALENT FEET. 5 UNIT PLAN - B HC - M06 SCALE: /" = '-0" UNIT B M - M06 SCALE: /" = '-0" SEE UNIT B- FOR LAYOUT UNIT B M - M06 SCALE: /" = '-0" SEE UNIT B- FOR LAYOUT UNIT B M - M06 SCALE: /" = '-0" DRYER DUCT = FEET LENGTH + 5 FEET FOR -90 DEGREE ELBOW AND.5 FEET FOR -5 DEGREE ELBOW = 5.5 EQUIVALENT FEET. UNIT PLAN - B - M06 SCALE: /" = '-0" 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 UNIT PLAN - B December 0, 05 M06 /9/05 5::0 PM C:\Users\aaguilar\\ _aaguilar.rvt

26 UP T A-X6 A-0X EF- DN "x" AHU- 6"x" A-0X EF- 0"x0" 0"x0" "ø A-X6 00 CFM EF- A-0X 9 0"x0" A-X6 0 CFM A-X6 00 CFM 0"x0" DN TO BELOW B-6x6 A-X6 UNIT B - M07 SCALE: /" = '-0" PROVIDE WALL CAP; PAINT TO MATCH EXTERIOR. ALL CAPS ARE TO BE HORIZONTALLY AND VERTICALLY ALIGNED ON ALL BUILDING FACADES. " DRYER DUCT. PROVIDE 6 GA. GALV. SHEET METAL DUCT. ROUTE DUCT IN SOFFIT PROVIDED, SEE ARCH PLANS FOR FURTHER DETAILING OF SOFFIT. VENT CONNECTION MUST BE " MAX. ABV. FIN. FLOOR. NOTE: NON-STACKED DRYER IS A GE MODEL GTXESS. ENSURE PROPER ACCESS TO THE UNIT IS AVAILABLE. SEE ARCHITECTURAL PLANS FOR ACCESS DOOR LOCATION. LAUNDRY ROOM. 5 ROUTE REFRIGERANT LINES TO ASSOCIATED AHU. 6 ALL BEDROOM DOORS SHALL BE UNDERCUT BY / INCH. 7 PROVIDE A B-x0 RETURN GRILLE OVER THE DOOR TO THE WASHER/DRYER CLOSET. GRILLE SHALL PROVIDE 00 SQ. IN. FREE AREA. CONTRACTOR TO ENSURE ALL EXHAUST AND DRYER TERMINATIONS WILL HAVE A ' MINIMUM CLEARANCE TO OPERABLE WINDOW OPENINGS. MEASUREMENT IS TO THE TOP SASH OPENING FOR DOUBLE HUNG WINDOWS. 9 PROVIDE A X MIN. RETURN GRILL OVER THE DOOR TO ALL BEDROOM CLOSETS, INTERIOR STORAGE ROOMS AND COAT CLOSETS. DRYER DUCT = 5 FEET LENGTH + 5 FEET FOR -90 DEGREE ELBOW AND.5 FEET FOR -5 DEGREE ELBOW =.5 EQUIVALENT FEET. UNIT B - ND FLR - M07 SCALE: /" = '-0" 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 UNIT PLAN - B December 0, 05 M07 /9/05 5:: PM C:\Users\aaguilar\\ _aaguilar.rvt

27 PROVIDE WALL CAP; PAINT TO MATCH EXTERIOR. ALL CAPS ARE TO BE HORIZONTALLY AND VERTICALLY ALIGNED ON ALL BUILDING FACADES. " DRYER DUCT. PROVIDE 6 GA. GALV. SHEET METAL DUCT. ROUTE DUCT IN SOFFIT PROVIDED, SEE ARCH PLANS FOR FURTHER DETAILING OF SOFFIT. VENT CONNECTION MUST BE " MAX. ABV. FIN. FLOOR. ENSURE PROPER ACCESS IN CLOSET TO THE RADIANT DAMPER IN THE SUPPLY DUCTWORK. PROVIDE FACTORY SUPPLIED RETURN/ACCESS PANEL FOR AHU WHERE INDICATED NOTE: NON-STACKED DRYER IS A GE MODEL GTXESS. 5 6 CLOSET. PROVIDE A PLENUM BOX FROM AHU UP TO TRUSS SPACE. CONTRACTOR TO COOINATE TRUSS LOCATIONS ABOVE AHU CLOSET TO ALLOW FOR DUCT PENETRATION. PROVIDE A RADIANT DAMPER AT CEILING PENETRATION. 7 ALL BEDROOM DOORS SHALL BE UNDERCUT BY / INCH. PROVIDE A B-x0 RETURN GRILLE OVER THE DOOR TO THE WASHER/DRYER CLOSET. GRILLE SHALL PROVIDE 00 SQ. IN. FREE AREA. 9 CONTRACTOR TO ENSURE ALL EXHAUST AND DRYER TERMINATIONS WILL HAVE A ' MINIMUM CLEARANCE TO OPERABLE WINDOW OPENINGS. MEASUREMENT IS TO THE TOP SASH OPENING FOR DOUBLE HUNG WINDOWS. 0 PROVIDE A X MIN. RETURN GRILL OVER THE DOOR TO ALL BEDROOM CLOSETS, INTERIOR STORAGE ROOMS AND COAT CLOSETS. STOR A-X6 EF- BEDROOM 7 A-0X STOR STOR W.I.C 0 "x0" LAUNDRY 90 PAN 9 HVAC 5 COAT B-0X AHU- 5 6 KITCHEN 9 A-X6 DINING 6 A-X6 00 CFM BATH 79 EF- A-0X BEDROOM 77 LIVING 7 A-X6 A-X6 T 5"ø M0 SCALE: /" = '-0" DRYER DUCT = FEET LENGTH + 5 FEET FOR -90 DEGREE ELBOW AND.5 FEET FOR -5 DEGREE ELBOW = 5.5 EQUIVALENT FEET. UNIT B HC - 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 UNIT PLAN - B HC December 0, 05 M0 /9/05 5::6 PM C:\Users\aaguilar\\ _aaguilar.rvt

28 UP A-X6 5 CFM 0"x0" EF- 9 A-0X T A-X6 5 CFM A-X6 5 CFM PROVIDE WALL CAP; PAINT TO MATCH EXTERIOR. ALL CAPS ARE TO BE HORIZONTALLY AND VERTICALLY ALIGNED ON ALL BUILDING FACADES. " DRYER DUCT. PROVIDE 6 GA. GALV. SHEET METAL DUCT. ROUTE DUCT IN SOFFIT PROVIDED, SEE ARCH PLANS FOR FURTHER DETAILING OF SOFFIT. VENT CONNECTION MUST BE " MAX. ABV. FIN. FLOOR. NOTE: NON-STACKED DRYER IS A GE MODEL GTXESS. ENSURE PROPER ACCESS TO THE UNIT IS AVAILABLE. SEE ARCHITECTURAL PLANS FOR ACCESS DOOR LOCATION. LAUNDRY ROOM. 5 ROUTE REFRIGERANT LINES TO ASSOCIATED AHU. 6 ALL BEDROOM DOORS SHALL BE UNDERCUT BY / INCH. 7 PROVIDE A B-x0 RETURN GRILLE OVER THE DOOR TO THE WASHER/DRYER CLOSET. GRILLE SHALL PROVIDE 00 SQ. IN. FREE AREA. CONTRACTOR TO ENSURE ALL EXHAUST AND DRYER TERMINATIONS WILL HAVE A ' MINIMUM CLEARANCE TO OPERABLE WINDOW OPENINGS. MEASUREMENT IS TO THE TOP SASH OPENING FOR DOUBLE HUNG WINDOWS. 9 PROVIDE A X MIN. RETURN GRILL OVER THE DOOR TO ALL BEDROOM CLOSETS, INTERIOR STORAGE ROOMS AND COAT CLOSETS. EF- A-0X A-X6 5 CFM AHU-5 DN EF- A-X6 5 CFM A-X6 5 CFM "x" 0"x0" DN TO BELOW 9 0"x0" 5 6 B-6x6 UNIT C - M09 SCALE: /" = '-0" A-0X 6 6 UNIT C - ND FLR - M09 SCALE: /" = '-0" 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 UNIT PLAN - C December 0, 05 M09 /9/05 5:: PM C:\Users\aaguilar\\ _aaguilar.rvt

29 BATH 99 EF- BATH 9 EF- BEDROOM 9 STOR 6 A-X6 W.I.C 0 A-X6 BEDROOM 00 COAT 0 A-0X STOR. 0 KITCHEN 05 UNIT C-HC 0 A-0X AHU- HVAC 97 "x0" A-X6 LAUNDRY 96 PORCH 7 LIVING 06 A-X6 BEDROOM 95 A-X6 T 5"ø NOTE: NON-STACKED DRYER IS A GE MODEL GTXESS B-0X 5 6 DRYER DUCT = FEET LENGTH + 5 FEET FOR -90 DEGREE ELBOW AND.5 FEET FOR -5 DEGREE ELBOW = 5.5 EQUIVALENT FEET. UNIT C HC - M0 SCALE: /" = '-0" PROVIDE WALL CAP; PAINT TO MATCH EXTERIOR. ALL CAPS ARE TO BE HORIZONTALLY AND VERTICALLY ALIGNED ON ALL BUILDING FACADES. " DRYER DUCT. PROVIDE 6 GA. GALV. SHEET METAL DUCT. ROUTE DUCT IN SOFFIT PROVIDED, SEE ARCH PLANS FOR FURTHER DETAILING OF SOFFIT. VENT CONNECTION MUST BE " MAX. ABV. FIN. FLOOR. ENSURE PROPER ACCESS IN CLOSET TO THE RADIANT DAMPER IN THE SUPPLY DUCTWORK. PROVIDE FACTORY SUPPLIED RETURN/ACCESS PANEL FOR AHU WHERE INDICATED CLOSET. PROVIDE A PLENUM BOX FROM AHU UP TO TRUSS SPACE. CONTRACTOR TO COOINATE TRUSS LOCATIONS ABOVE AHU CLOSET TO ALLOW FOR DUCT PENETRATION. PROVIDE A RADIANT DAMPER AT CEILING PENETRATION. ALL BEDROOM DOORS SHALL BE UNDERCUT BY / INCH. PROVIDE A B-x0 RETURN GRILLE OVER THE DOOR TO THE WASHER/DRYER CLOSET. GRILLE SHALL PROVIDE 00 SQ. IN. FREE AREA. CONTRACTOR TO ENSURE ALL EXHAUST AND DRYER TERMINATIONS WILL HAVE A ' MINIMUM CLEARANCE TO OPERABLE WINDOW OPENINGS. MEASUREMENT IS TO THE TOP SASH OPENING FOR DOUBLE HUNG WINDOWS. PROVIDE A X MIN. RETURN GRILL OVER THE DOOR TO ALL BEDROOM CLOSETS, INTERIOR STORAGE ROOMS AND COAT CLOSETS. 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 UNIT PLAN - C HC December 0, 05 M0 /9/05 5::7 PM C:\Users\aaguilar\\ _aaguilar.rvt

30 BUILDING A - APARTMENT SPLIT SYSTEM DX HEAT PUMP SCHEDULE SYSTEM NUMBER AHU-/HP- AHU-/HP- AREA SERVED BED BED MANUFACTURER GOODMAN GOODMAN MIN. SYSTEM S.E.E.R/E.E.R. (@ ARI).5/--.5/-- MIN. SYSTEM H.S.P.F/C.O.P. (@ ARI)./--./-- INDOOR UNIT NUMBER AHU- AHU- SUPPLY AIRFLOW (CFM) 60 5 EXT. STATIC (IN. W.G.) EVAP. FAN HP / / AUX ELEC. HEAT AT 0 V (kw) 5 UNIT VOLTS/PHASE/HZ. 0//60 0//60 ENT. AIR TEMP. DB/WB (DEG F) 0/67 0/67 NET TOTAL COOLING (BTU/H) 7,00,00 NET SENSIBLE COOLING (BTU/H),600,00 REV. CYCLE HEATING 7 DEG F) 7,00,000 7/0 /0 MODEL NUMBER AWUF AWUF OUTDOOR UNIT NUMBER HP- HP- AMBIENT TEMP. (DEG. F) UNIT VOLT/PHASE/HZ. 0//60 0//60 MCA/MCOP./0 5/5 MODEL NUMBER GSZ0K GSZ0K REMARKS THRU THRU NOTES:. PROVIDE AHU WITH SINGLE POINT POWER CONNECTION.. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL DISCONNECT SWITCH.. PROGRAMMABLE THERMOSTAT. TIME DELAY RELAY & THERMAL EXPANSION VALVE. 5. FILTER RACK W/ T-A FILTERS. 6. FILTER DRIER. 7. COMPRESSOR START ASSIST.. HIGH & LOW PRESSURE SWITCHES. 9. CRANKCASE HEATER. 0. SIZE REFRIGERANT LINES PER MANUFACTURER'S RECOMMENDATIONS FOR MINIMUM CAPACITY LOSS.. PROVIDE CONDENSATE OVERFLOW SWITCH.. PROVIDE R-0A REFRIGERANT. BUILDINGS B, C AND D - APARTMENT SPLIT SYSTEM DX HEAT PUMP SCHEDULE SYSTEM NUMBER AHU-/HP- AHU-/HP- AHU-/HP- AHU-/HP- AHU-5/HP-5 AREA SERVED BED BED BED BED BED MANUFACTURER GOODMAN GOODMAN GOODMAN GOODMAN GOODMAN MIN. SYSTEM S.E.E.R/E.E.R. (@ ARI).5/--.5/--.0/--.0/--.0/-- MIN. SYSTEM H.S.P.F/C.O.P. (@ ARI)./--./--./--./--./-- INDOOR UNIT NUMBER AHU- AHU- AHU- AHU- AHU-5 SUPPLY AIRFLOW (CFM) EXT. STATIC (IN. W.G.) EVAP. FAN HP / / / / / AUX ELEC. HEAT AT 0 V (kw) UNIT VOLTS/PHASE/HZ. 0//60 0//60 0//60 0//60 0//60 ENT. AIR TEMP. DB/WB (DEG F) 0/67 0/67 0/67 0/67 0/67 NET TOTAL COOLING (BTU/H) 7,00,00 7,00,00,000 NET SENSIBLE COOLING (BTU/H),600,00 0,600,600 0,00 REV. CYCLE HEATING 7 DEG F) 7,00,000,000,00 7,00 0/5 /5 56/60 /5 5/60 MODEL NUMBER AWUF AWUF AWUF ARUF5 ARUF OUTDOOR UNIT NUMBER HP- HP- HP- HP- HP-5 AMBIENT TEMP. (DEG. F) UNIT VOLT/PHASE/HZ. 0//60 0//60 0//60 0//60 0//60 MCA/MCOP./0 5/5 /0 5/5 /0 MODEL NUMBER GSZ0K GSZ0K GSZ00K GSZ0K GSZ00K REMARKS THRU THRU THRU THRU THRU NOTES:. PROVIDE AHU WITH SINGLE POINT POWER CONNECTION.. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL DISCONNECT SWITCH.. PROGRAMMABLE THERMOSTAT. TIME DELAY RELAY & THERMAL EXPANSION VALVE. 5. FILTER RACK W/ T-A FILTERS. 6. FILTER DRIER. 7. COMPRESSOR START ASSIST.. HIGH & LOW PRESSURE SWITCHES. 9. CRANKCASE HEATER. 0. SIZE REFRIGERANT LINES PER MANUFACTURER'S RECOMMENDATIONS FOR MINIMUM CAPACITY LOSS.. PROVIDE CONDENSATE OVERFLOW SWITCH.. PROVIDE R-0A REFRIGERANT. BUILDING A - AMENITY SPLIT SYSTEM DX HEAT PUMP SCHEDULE SYSTEM NUMBER.5 TON TON TON TON 5 TON AREA SERVED CORRIDORS GYM/CORRIDOR LEASING MULTI PURP. INDOOR SITTING MANUFACTURER GOODMAN GOODMAN GOODMAN GOODMAN GOODMAN MIN. SYSTEM S.E.E.R/E.E.R. (@ ARI).0/--.0/--.0/--.0/--.0/-- MIN. SYSTEM H.S.P.F/C.O.P. (@ ARI)./--./--./--./--./-- INDOOR UNIT NUMBER AHU-A, 6A THRU 9A AHU-A AHU-A AHU-A AHU-5A SUPPLY AIRFLOW (CFM) OUTSIDE AIRFLOW (CFM) EXT. STATIC (IN. W.G.) EVAP. FAN HP / / / / / AUX ELEC. HEAT AT 0 V (kw) 0 0 UNIT VOLTS/PHASE/HZ. 0//60 0//60 0//60 0//60 0//60 ENT. AIR TEMP. DB/WB (DEG F) 0/67 0/67 0/67 0/67 0/67 NET TOTAL COOLING (BTU/H),000,000,00,00 56,500 NET SENSIBLE COOLING (BTU/H) 0,00 6,000 5,00 5,00,00 REV. CYCLE HEATING 7 DEG F) 7,00,000,00,00 59,000 0/ / 7/50 0/0 0/0 56/60 MODEL NUMBER ARUF ARUF9 ARUF7 ARUF7 ASPT6 OUTDOOR UNIT NUMBER HP-A, 6A THRU 9A HP-A HP-A HP-A HP-5A AMBIENT TEMP. (DEG. F) UNIT VOLT/PHASE/HZ. 0//60 0//60 0//60 0//60 0//60 MCA/MCOP /0 5/0 0/5 0/5 5/60 MODEL NUMBER GSZ00A GSZ0A GSZ06A GSZ06A GSZ060A REMARKS THRU THRU THRU THRU THRU NOTES:. PROVIDE AHU WITH SINGLE POINT POWER CONNECTION.. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL DISCONNECT SWITCH.. ELECTRONIC PROGRAMMABLE THERMOSTAT.. TIME DELAY RELAY & THERMAL EXPANSION VALVE. 5. FILTER RACK W/ T-A FILTERS. 6. FILTER DRIER. 7. COMPRESSOR START ASSIST.. HIGH & LOW PRESSURE SWITCHES. 9. CRANKCASE HEATER. 0. SIZE REFRIGERANT LINES PER MANUFACTURER'S RECOMMENDATIONS FOR MINIMUM CAPACITY LOSS.. PROVIDE CONDENSATE OVERFLOW SWITCH.. PROVIDE R-0A REFRIGERANT. BUILDING C - AMENITY SPLIT SYSTEM DX HEAT PUMP SCHEDULE SYSTEM NUMBER TON AREA SERVED FITNESS 09 MANUFACTURER GOODMAN MIN. SYSTEM S.E.E.R/E.E.R. (@ ARI).0/-- MIN. SYSTEM H.S.P.F/C.O.P. (@ ARI)./-- INDOOR UNIT NUMBER AHU-0A SUPPLY AIRFLOW (CFM) 70 OUTSIDE AIRFLOW (CFM) 60 EXT. STATIC (IN. W.G.) 0.5 EVAP. FAN HP / AUX ELEC. HEAT AT 0 V (kw) UNIT VOLTS/PHASE/HZ. 0//60 ENT. AIR TEMP. DB/WB (DEG F) 0/67 NET TOTAL COOLING (BTU/H),00 NET SENSIBLE COOLING (BTU/H),600 REV. CYCLE HEATING 7 DEG F),00 0/ /5 MODEL NUMBER ARUF5 OUTDOOR UNIT NUMBER HP-0A AMBIENT TEMP. (DEG. F) 95 UNIT VOLT/PHASE/HZ. 0//60 MCA/MCOP 5/5 MODEL NUMBER GSZ0A REMARKS THRU NOTES:. PROVIDE AHU WITH SINGLE POINT POWER CONNECTION.. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL DISCONNECT SWITCH.. ELECTRONIC PROGRAMMABLE THERMOSTAT.. TIME DELAY RELAY & THERMAL EXPANSION VALVE. 5. FILTER RACK W/ T-A FILTERS. 6. FILTER DRIER. 7. COMPRESSOR START ASSIST.. HIGH & LOW PRESSURE SWITCHES. 9. CRANKCASE HEATER. 0. SIZE REFRIGERANT LINES PER MANUFACTURER'S RECOMMENDATIONS FOR MINIMUM CAPACITY LOSS.. PROVIDE CONDENSATE OVERFLOW SWITCH.. PROVIDE R-0A REFRIGERANT. 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 Revision Date SCHEDULES 5-00 December 0, 05 M50 /9/05 5:: PM C:\Users\aaguilar\\ _aaguilar.rvt

31 UNIT HEATER SCHEDULE DESIGNATION UH- AREA SERVED STAIRWELL/SPRINKLER ROOM MANUFACTURER MARKEL MODEL N0. FT OUTPUT (KW) 5 AIR TEMP RISE 5 AMPS VOLTAGE / PHASE 0/ WEIGHT (LBS) NOTES:. PROVIDE UNIT TEMPERATURE CONTROL THERMOSTAT, SUMMER FAN SWITCH AND POWER DISCONNECT SWITCH.. PROVIDE ALL RELAYS AND TRANSFORMERS FOR A COMPLETELY OPERATIONAL SYSTEM. EXHAUST FAN SCHEDULE DESIGNATION EF- EF-, EF-,5 LOCATION CEILING CEILING CEILING AIRFLOW (CFM) DRIVE TYPE DIRECT DIRECT DIRECT EXT. STATIC (in. wg.) FAN SPEED (RPM) INPUT HP (WATTS) (60.5) (60.5) (00) VOLTAGE/PHASE 0/ 0/ 0/ ACCESSORIES A, B, C, D A, B, C, D A, B, C, D CONTROL TYPE MANUFACTURER COOK COOK COOK MODEL NO. GC- GC- GC- NOTES: CONTROL TYPE:. INTERLOCK WITH WALL SWITCH.. RUN CONTINUOUSLY. ACCESSORIES: A. BACKDRAFT DAMPER B. DISCONNECT SWITCH C. SOLID STATE SPEED CONTROLLER D. VIBRATION ISOLATORS AIR DISTRIBUTION DEVICE SCHEDULE A - HART & COOLEY MODEL 6M CEILING DIFFUSER (W/O.B.D.) B - HART & COOLEY MODEL 650 RETURN GRILLE C - HART & COOLEY MODEL 6 CEILING DIFFUSER (W/O.B.D.) D - HART & COOLEY MODEL 6 SIDEWALL DIFFUSER (W/O.B.D.) NOTES:. COLOR TO BE SPECIFIED BY ARCHITECT.. NECK SIZES TO MATCH SIZE OF DUCTWORK TO EACH AIR DEVICE.. PROVIDE U.L. RADIATION DAMPERS ON SUPPLY DIFFUSERS. EACH AIR DEVICE SHALL HAVE A VOLUME DAMPER IN THE DUCT CONNECTED TO THE DEVICE UNLESS NOTED OTHERWISE. IF AIR DEVICE IS LOCATED IN AN INACCESSIBLE CEILING, VOLUME DAMPER SHALL BE INTEGRAL WITH THE AIR DEVICE. -WAY THROW -WAY THROW -WAY OPPOSITE THROW -WAY CORNER THROW -WAY THROW 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 SCHEDULES 5-00 December 0, 05 M50 /9/05 5::9 PM C:\Users\aaguilar\\ _aaguilar.rvt

32 5'-0" MAX. FIRE CAULK DRYER VENT PENETRATION OF DOUBLE TOP PLATE. RIGID METAL DRYER VENT ABOVE CEILING TO CAP ON EXTERIOR WALL. PROVIDE FIRE WRAP IF REQUIRED BY LOCAL AHJ. RIGID METAL DRYER VENT PIPE IN WALL. /" SCH. 0 PVC FROM SECONDARY DRAIN CONNECTION EZ TRAP MODEL EZT-5 CONNECT SWITCH TO SHUT DOWN SYSTEM ON OVERFLOW " PIPE EXTENSION WITH SCREW CAP FACTORY ASSEMBLED HINGED HOOD WITH LATCH AND BI SCREEN. INSECT SCREEN GALVANIZED, INSULATED PREFAB CURB WITH BUILT-IN CANT. WOOD NAILING STRIP SEE NOTE FLASHING SEE NOTE EXTERIOR WALL CEILING SPACE CONDENSING UNIT 6" MIN. OR AS OTHERWISE NOTED. SECURE PIPING TO WALL WITH FASTENERS AND BRACKETS. FINISHED WALL GRADE FLOOR " THK. CONC. PAD /''ø x " EXPANSION BOLT (TYP OF ) SLOPE LINES, DOWN, TOWA OUTSIDE SEAL WATER TIGHT. ROUTE REFRIGERANT LINES UP ALONG INTERIOR OF BUILDING. FOOTING HANGER SUPPORTS: " X GA, DO NOT SUPPORT FROM CEILING. INTEGRAL BACKDRAFT DAMPER FAN VARIABLE SPEED CONTROLLER MARK WITH THE "AS BALANCED POSITION" (DIRECT DRIVE UNITS). INTEGRAL RADIATION DAMPER DISCONNECT SWITCH: FURNISHED BY CONTRACTOR OR FAN MANUFACTURER. CEILING INSULATED FLEXIBLE DUCT BELLMOUTH FITTING WITH DAMPER SUPPLY DUCT INSULATION TO RUN UP TO DUCT " MIN. OR MAX. AVAILABLE ALTERNATE LOCATION FOR DUCT CONNECTION TIE STRAP /" FIBERGLASS FOIL BACKED INSULATION ON ALL SURFACES SUBJECT TO CONDENSATION ABOVE THE CEILING. PROVIDE VAPOR TIGHT SEAL. CEILING SUPPLY DIFFUSER 65 FUSIBLE LINK 65 FUSIBLE LINK DUCT DROP RADIANT CEILING DAMPER GA. STEEL WIRE 6 GA. x /'' CHANNEL RADIANT CEILING DAMPER CEILING ASSEMBLY SHEET METAL SCREW (TYPICAL) SUPPLY GRILLE " MIN. U.O.N. 5'-0" MAX. " 7" 5" " DEDUCT 5'-0" FOR EA. ADDITIONAL 90 ELBOW 90 LONG SWEEP ELBOW WALL CAP " x " x 5" SHEET METAL TERMINAL BOX IN WALL WITH 5"ø TOP CONNECTION RESIDENTIAL CLOTHES DRYER FLEXIBLE METAL DRYER VENT. 7 DRYER VENT DETAIL M60 SCALE: NTS M60 SECONDARY CONDENSATE DRAIN SWITCH DETAIL SCALE: NTS SEE NOTE INSULATION ROOF DECK GRAVITY BACK DRAFT DAMPER ON EXHAUST HOOD ONLY. P.T. BLOCKING (AS REQUIRED) TRANSITION DUCT TO FULL SIZE OF DAMPER SUPPLIED WITH HOOD. DUCT (WHERE APPLICABLE) NOTES:. SECURE CURB CAP TO WOOD NAILING STRIP WITH /" STAINLESS STEEL LAG BOLTS NOT OVER " ON CENTER.. SECURE ROOF CURB, DUCT WORK AND DAMPER TO ROOF WITH EXPANSION BOLTS (CONCRETE ROOF) OR RUST RESISTANT BOLTS (METAL DECK AND BAR JOIST ROOF).. SIZE OF DUCT THROUGH ROOF SHALL NOT BE LARGER THAN CURB SUPPLIED WITH ROOF VENTILATOR. 9 ROOF MOUNTED OUTSIDE AIR INTAKE M60 SCALE: NTS U.L. LISTED CEILING RADIATION DAMPER AT DUCT PENETRATION OF FIRE-RATE CEILING "x" ACCESS PANEL FOR FIRE DAMPER HW SUPPLY AHU BALL VALVE TYP. REFRIGERANT PIPING DO NOT BLOCK FILTER ACCESS WITH PIPING FLOAT SWITCH ON SECONDARY DRAIN WIRED TO SHUT DOWN UNIT UPON ACTIVATION BY WATER IN CONDENSATE LINE. CONDENSATE DRAIN LINE WITH 6" DEEP P-TRAP LOW-BOY WATER HEATER TERMINATE /" CONDENSATE DRAIN LINE INTO HUB DRAIN WITH " AIR GAP. HUB DRAIN WITH TRAP GUA; SEE PLUMBING. CLOSET DETAIL M60 SCALE: NTS 5 CONDENSING UNIT DETAIL M60 SCALE: NTS FILTER ACCESS DO NOT BLOCK ACCESS TO CIRCUIT BREAKER OR CONTROL PANEL RETURN DUCT SUPPLY DUCT COIL SECTION FAN SECTION CONDENSATE DRAIN LINE WITH " DEEP P-TRAP FULL SIZE OF UNIT CONNECTION x WOOD BLOCKING AS REQUIRED TO FORM P-TRAP IN CONDENSATE LINE FLOAT SWITCH WIRED TO SHUT DOWN UNIT UPON ACTIVATION BY WATER IN AUXILIARY PAN AUXILIARY DRAIN PAN UNDER FULL WIDTH AND LENGTH OF UNIT '' THICK NEOPRENE PAD (TYPICAL OF ) 6 HORIZONTAL AIR HANDLING UNIT DETAIL M60 SCALE: NTS CEILING MOUNTED FAN DETAIL M60 SCALE: NTS TYPICAL FLEX DUCT CONNECTION DIAGRAM M60 SCALE: NTS CEILING RADIANT DAMPER DETAIL M60 SCALE: NTS 9 R.G. Skinner Parkway 0 West Morehead Street, Suite 0 T: F: c 05 Revision Date DETAILS 5-00 December 0, 05 M60 /9/05 5::0 PM C:\Users\aaguilar\\ _aaguilar.rvt

SHOE PALACE HUNTINGTON PARK M.200

SHOE PALACE HUNTINGTON PARK M.200 M.200 SPLIT SYSTEM CONDENSING UNIT SCHEDULE MARK SERVICE MODEL NO. COOLING DIMENSIONS ELECTRICAL REMARKS CAPACITY AMBIENT DB REFRIGERANT LENGTH WIDTH HEIGHT WEIGHT VOLT/PHASE MCA MOP (MBH) (DEG F) (IN)

More information

EXHAUST FAN SCHEDULE

EXHAUST FAN SCHEDULE DUCTWORK SCHEDULE CONCEALED SUPPLY AIR RECTANGULAR, RTU CONCEALED SUPPLY AIR RECTANGULAR, ERV CONCEALED SUPPLY AIR ROUND, RTU CONCEALED SUPPLY AIR ROUND, ERV EXPOSED SUPPLY AIR ROUND RUNOUTS RETURN AIR

More information

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS 48GS-1SB 48GS018-060 HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1998 Carrier Corporation Syracuse,

More information

HVAC LEGEND HVAC ABBREVIATIONS PLUMBING LEGEND PLUMBING ABBREVIATIONS PRELIMINARY NOT FOR CONSTRUCTION

HVAC LEGEND HVAC ABBREVIATIONS PLUMBING LEGEND PLUMBING ABBREVIATIONS PRELIMINARY NOT FOR CONSTRUCTION GENERAL NOTES SPECIFICATIONS LEGEND SYMBOL DESCRIPTION ABBREV. SYMBOL DESCRIPTION ABBREV. SYMBOL DESCRIPTION ABBREV. ABBREVIATIONS PLUMBING LEGEND SYMBOL DESCRIPTION ABB. SYMBOL DESCRIPTION ABB. SYMBOL

More information

Architectural Alliance Incorporated MDP CONSULTING ENGINEERS, INC N 11th Street Beaumont, TX 77702

Architectural Alliance Incorporated MDP CONSULTING ENGINEERS, INC N 11th Street Beaumont, TX 77702 04/08/2013 last saved: TRENT plotted: DRAWN BY: TLH CHECKED BY: DWD 04/08/2013 last saved: DMCPHERSON plotted: DRAWN BY: TLH CHECKED BY: DWD 04/08/2013 last saved: DMCPHERSON plotted: DRAWN BY: TLH CHECKED

More information

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT -1SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP S W/OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier

More information

COMcheck Software Version Interior Lighting Compliance Certificate

COMcheck Software Version Interior Lighting Compliance Certificate Section 1: Project Information Energy Code: 2009 IECC Project Title: Berry Farms Animal Hospital Project Type: New Construction COMcheck Software Version 4.0.3.0 Interior Lighting Compliance Certificate

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel

More information

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS 48GS(N)018-060 STANDARD EFFICIENCY 48GX(N)024-060 HIGH-EFFICIENCY 48GS(N)-2SB SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION

More information

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS -3SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING S PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier Corporation

More information

SAFETY AND INSTALLATION MANUAL MODEL 8100

SAFETY AND INSTALLATION MANUAL MODEL 8100 SAFETY AND INSTALLATION MANUAL ENERGY RECOVERY VENTILATORS MODEL 8100 Provides year-round fresh air Recovers 77% of the apparent heating or cooling energy from the exhausted air See Warnings Page 3 Table

More information

DRAWING SCHEDULE TAB REQUIREMENTS BY EQUIPMENT TYPE TYPE OF EQUIPMENT DESCRIPTION COMPONENT TAB REQUIREMENTS

DRAWING SCHEDULE TAB REQUIREMENTS BY EQUIPMENT TYPE TYPE OF EQUIPMENT DESCRIPTION COMPONENT TAB REQUIREMENTS DRAWING SCHEDULE NUMBER TITLE M0-1 MECHANICAL NOTES AND LEGEND M1-0 MECHANICAL FLOOR PLAN M4-0 MECHANICAL SCHEDULES M4-1 MECHANICAL LOAD CALCULATIONS M5-0 MECHANICAL DETAILS M8-0 TCS BASYS CONTROLS DRAWINGS

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

High Heat COP. High/Low Stage

High Heat COP. High/Low Stage SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin

More information

Technical Assignment 3 11/15/04. Executive Summary

Technical Assignment 3 11/15/04. Executive Summary Executive Summary This report is an analysis of the existing systems within the Outreach Innovation Building in University Park, PA. One significant design criteria was a lower than average noise criteria

More information

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units TECHNICAL SPECIFICATIONS R7DA Series 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units 5.4 ISMRE Commercial System 81% Steady State Efficiency Standard Features Fits Pre-Existing Curbs High-Efficiency Low

More information

Inspection Checklist Mechanical Rough in

Inspection Checklist Mechanical Rough in Property Owner Name: Property Address: Permit Number: Inspectors Name: Review Date: Permits and Plans 1. Job address is posted in a visible location. (R319.1) 2. Permit and approved plans are on site and

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT Taylor Engineering 1080 Marina Village Parkway, Suite 501 Alameda, CA 94501-1142 (510) 749-9135 Fax (510) 749-9136 LLC HVAC DESIGN INTENT PART 1 - GENERAL 1.1 Overview A. The project consists of a 3-story

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

DIVISION 15 MECHANICAL

DIVISION 15 MECHANICAL DIVISION 15 MECHANICAL A. GENERAL DESIGN CONDITIONS 1. Design occupied spaces to maintain 72 F and a space dew point temperature not to exceed 55 F. 2. Design classroom and office space buildings with

More information

62DA,DB,DC,DD,DE,DF07-38

62DA,DB,DC,DD,DE,DF07-38 62D-3SB 62DA,DB,DC,DD,DE,DF07-38 DEDICATED VERTICAL OR HORIZONTAL 100% OUTDOOR AIR UNIT PERFORMANCE DATA UNIT DIMENSION PRINTS ACCESSORY DIMENSION PRINTS Copyright 2011 Carrier Corporation Syracuse, New

More information

48TF GAS HEATING/ ELECTRIC COOLING UNITS

48TF GAS HEATING/ ELECTRIC COOLING UNITS 48TF-4SB 48TF004-014 GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form

More information

HVAC Equipment Access Equipment Location

HVAC Equipment Access Equipment Location City of Lancaster- Building Department 121 East Chestnut Street, Suite 102, Lancaster, Ohio 43130-3825 (740) 687-6649, Fax (740) 681-5030 Web site: www.ci.lancaster.oh.us/dept/building HVAC Heating, Ventilating,

More information

36,000-62,000 BTUH Nominal Capacity

36,000-62,000 BTUH Nominal Capacity 36,000-62,000 BTUH Nominal Capacity STANDARD EQUIPMENT 2TEE3F62A, 4TEE3F62B VARIABLE SPEED AIR HANDLER Ships horizontal - converts to vertical by standing on end. Six-way convertibility-horizontal (left

More information

Modular Supply Make-Up Air Unit

Modular Supply Make-Up Air Unit Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features

More information

48TM GAS HEATING/ELECTRIC COOLING UNITS

48TM GAS HEATING/ELECTRIC COOLING UNITS 48TM-4SB 48TM004-014 GAS HEATING/ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form

More information

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

More information

SECTION AIR DUCT ACCESSORIES

SECTION AIR DUCT ACCESSORIES SECTION 23 33 00 AIR DUCT ACCESSORIES PART 1 - GENERAL 1.1 SUMMARY A. Section includes back-draft dampers, combination fire-and-smoke dampers, duct access doors, fire dampers, smoke dampers, volume control

More information

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed

More information

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional

More information

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements

ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements ADDENDUM 1 CLIENT: PROJECT: TO: FROM: Guilford County Schools (GCS) Southeast High School Auditorium & Gymnasium HVAC Improvements All Prospective Bidders Derrick Giles, SAMR, PLLC. DATE: 6/6/2018 The

More information

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium

More information

1.1 This section applies to air handling units for HVAC Systems.

1.1 This section applies to air handling units for HVAC Systems. AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling

More information

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING SOUND REFRIGERANT ENVIRONMENTALLY PAN5 Product Specifications 15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R--410A refrigerant

More information

Technical Assignment 1

Technical Assignment 1 Technical Assignment 1 ASHRAE Standard 62.1 2007 Ventilation Compliance Evaluation Prepared For: Dr. James D. Freihaut, PhD Department of Architectural Engineering The Pennsylvania State University Prepared

More information

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ E3FB090/E1FB120/F3EH090 & 120 7-1/2 & 10 NOMINAL TONS (60 HZ) 7 & 9 NOMINAL TONS (50 HZ) (9.0-9.2 EER) 208/230/460 VOLT ONLY 208/230 VOLT ONLY DESCRIPTION YORK has

More information

TAG: RTU-2B 3B 4B 5B 6B 7B 1E MODEL: QTY. (7) 48TCED14A3A5-0B0A0 PACKAGED GAS/ELECTRIC ROOF TOP UNITS

TAG: RTU-2B 3B 4B 5B 6B 7B 1E MODEL: QTY. (7) 48TCED14A3A5-0B0A0 PACKAGED GAS/ELECTRIC ROOF TOP UNITS SUBMITTAL ***FOR APPROVAL*** TAG: RTU-2B 3B 4B 5B 6B 7B 1E MODEL: QTY. (7) 48TCED14A3A5-0B0A0 PACKAGED GAS/ELECTRIC ROOF TOP UNITS Project 66 Orland Square Dr. Landlord Renovations Location Orland Park,

More information

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons 560.20-TG1Y (388) EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons Each circuit includes a fully hermetic compressor with a crankcase

More information

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS EA090/FA090 DESCRIPTION YORK has combined the latest concepts in modern technology with time-proven quality standards to design a split-system heat pump to meet

More information

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS 48HJ-13SB Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT

More information

VariCool VAV Engineering Guide

VariCool VAV Engineering Guide Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control

More information

Florida Department of Transportation

Florida Department of Transportation Page 1 of 7 RICK SCOTT GOVERNOR Florida Department of Transportation 1109 S. Marion Avenue Lake City, Florida 32025 ANANTH PRASAD SECRETARY September 27, 2011 To: Proposal Holders Addendum No: 1, E2Q23,

More information

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

More information

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS 036-21096-001 (0101) SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The

More information

Modular Heating & Ventilating Unit Model IGX-HV

Modular Heating & Ventilating Unit Model IGX-HV Modular Heating & Ventilating Unit Model IGX-HV Indirect Gas-Fired Heating Evaporative Chilled Water DX Cooling October 2008 Product Features Model IGX-HV Indirect Gas-Fired Heating and Ventilating Unit

More information

Now In Production JULY 2008

Now In Production JULY 2008 Now In Production JULY 2008 OptiSolar, McClellan, CA Nine (9) Custom new single-zone units with 135 tons of DX cooling, air cooled condensing sections and direct drive supply air blowers. Ambient design

More information

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN Introduction to HVAC Agenda Psychrometrics Human Comfort Heat Transfer Refrigeration Cycle HVAC Terminology HVAC Systems Introduction to HVAC Psychrometrics 2000 TRG-TRC002-EN Properties of Air Dry-bulb

More information

PAR5. Product Specifications

PAR5. Product Specifications TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced

More information

SECTION AIR HANDLING UNIT

SECTION AIR HANDLING UNIT SECTION 15800 - AIR HANDLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR

More information

900 N. Via Piemonte Ontario, CA

900 N. Via Piemonte Ontario, CA 2 3 L 8 5'-0" 6'-1" 5'-0" 4'-0" 2'-0" D.5 6" 9'-9" K 2 1 2 " 5'-0" 2'-0" 1'-2" 8" 4 4.3 7'-0" C.6 1'-8 1 2 " 7'-0" 8" 10'-6" 5'-0" 8" 6" 6'-6" 6'-3" PLUMBING SCOPE OF WORK - DRAINS 7'-3" 6'-8" KEC TO PROVIDE:

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

MONROE MIDDLE SCHOOL SCHOOL

MONROE MIDDLE SCHOOL SCHOOL MONROE MIDDLE SCHOOL SCHOOL MONOE MIDDLE SCHOOL EUGENE, OR 97401 C001 COVER SHEET M001 MECHANICAL NOTES, SYMBOLS & ABBREVIATIONS M100 MECHANICAL PARTIAL PLANS DEMOLITION M101 MECHANICAL PARTIAL PLANS NEW

More information

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units TECHNICAL SPECIFICATIONS P8SE Series 14 SEER, Single Phase Packaged Air Conditioner 3, 4, 5 Ton Units The P8 Series single packaged air conditioners are high efficiency self contained cooling units that

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

DACC Health Sciences Building Air Handler Assessment/Study

DACC Health Sciences Building Air Handler Assessment/Study DACC Health Sciences Building Air Handler Assessment/Study NMSU Facilities and Services Department P.O. Box 30001 Las Cruces, NM 88003-8001 June 14, 2016 Final Submittal 1065 S. Main St., Bldg. D, Ste.

More information

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: DCC Commercial 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling

More information

Duct Free Systems Product Data Digest ¾ to 5 Nominal Tons

Duct Free Systems Product Data Digest ¾ to 5 Nominal Tons Duct Free Systems Product Data Digest ¾ to 5 Nominal Tons Console Console Condenser & Mulit-Zone Satellite HDC, HDL, HDS & QR Condensers High Wall AN/BK Condensers Under Ceiling Cassette Copyright 2001

More information

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons Product Data 50JS Single-Packaged Heat Pump Units 1 1/2 to 5 Nominal Tons UNIT 50JS (STANDARD) Single-Packaged Heat Pump for Residential and Light Commercial Applications Low Sound Levels 10 SEER Features/Benefits

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model Q4SD Series M120 Product Line Single Packaged Heat Pump 13 SEER 3-5 Ton Units 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise to replace

More information

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

A. General: Refer to paragraph entitled SUBMITTAL in Section Include the following data: SECTION 15860 - FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR MECHANICAL

More information

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Technical Development Program COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Introduction System

More information

REPLACEMENT PARTS LIST

REPLACEMENT PARTS LIST REPLACEMENT PARTS LIST PACKAGED AC UNIT WITH OPTIONAL ELECTRIC HEAT P7TQ SERIES 6-, 7.5-, AND 10-TON IMPORTANT This document is primarily intended to assist qualified individuals experienced in the proper

More information

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges. Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The

More information

Mechanical Technical Report 1. ASHRAE Standard 62.1 Ventilation Compliance Evaluation

Mechanical Technical Report 1. ASHRAE Standard 62.1 Ventilation Compliance Evaluation Mechanical Technical Report 1 Standard 62.1 Ventilation Compliance Evaluation Lutheran Theological Seminary at Philadelphia The New Learning Center Prepared For: William P. Bahnfleth, Ph.D., P.E. Department

More information

Model 655A Sizes

Model 655A Sizes Bryant Air Conditioning SINGLE PACKAGE HEAT PUMP S Model 655A Sizes 018-060 1 1 2 to 5 Tons DESCRIPTION Model 655A is our latest generation of packaged heat pumps for manufactured housing, residential,

More information

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners DCG Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant

More information

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors

More information

DCG Commercial. Submittal Data Form

DCG Commercial. Submittal Data Form DCG Commercial Submittal Data Form 15-25 Tons Packaged Gas / Electric Units 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h 25 Tons Cooling Capacity: 290,000 BTU/h 15 Tons

More information

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series 1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT: GENERAL SPECIFICATIONS OUTDOOR UNIT: TECHNICAL GUIDE COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM MODELS HB 180 & HB 240 MODELS LB 180 & LB 240 15 & 20 NOMINAL TONS 9.7 EER Two independent refrigerant

More information

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED (491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

FCC Fan-Coil Units High-Performance, Vertical

FCC Fan-Coil Units High-Performance, Vertical FCC Fan-Coil s High-Performance, Vertical Model FCC construction features Piping and supply-duct connections are from top of unit, eliminating the need for side or back access Right or left-hand configurations

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management System Due to continuous product

More information

48PGD/E/F/L/M/N PG20-28

48PGD/E/F/L/M/N PG20-28 48/50PG-10SB 48PGD/E/F/L/M/N20-28 50PG20-28 SINGLE-PACKAGE COOLING UNITS WITH FACTORY-INSTALLED GAS HEAT SINGLE-PACKAGE COOLING UNITS WITH OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

50TM COMBINATION HEATING/COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS 50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form

More information

Snohomish County PUD #1 HEAT PUMP SYSTEM INSTALLATION STANDARDS

Snohomish County PUD #1 HEAT PUMP SYSTEM INSTALLATION STANDARDS Snohomish County PUD #1 HEAT PUMP SYSTEM INSTALLATION STANDARDS April 2018 Topic TABLE OF CONTENTS Pages A. INTRODUCTION 5 B. DEFINITIONS 5 1. Shall 5 2. Should 5 C. CUSTOMER ELIGIBILITY 5 1. Single Family

More information

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece

More information

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER DCC Series Submittal Data Form Job Name 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By:

More information

SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through 2 tons, up to 47,800 BTUH Heating

SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through 2 tons, up to 47,800 BTUH Heating SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through tons, up to 7,800 BTUH Heating The SPXB-HW Series "Suite 0" is a compact, throughthe-wall single package vertical HVAC

More information

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer SUBMITTAL Project CLU Swenson Center Date 01/07/2010 Mechanical Contractor West Coast Air Conditioning Mechanical Engineer J & S Consulting Engineers, Inc. Revision Notes RTU-101, 102, 103, 201, 202, 203,

More information

Indirect Gas-Fired Make-Up Air

Indirect Gas-Fired Make-Up Air Indirect Gas-Fired Make-Up Air Model IG 800 to 7,000 cfm Up to 400,000 Btu/hr Multiple Furnace Control Options Optional Evaporative Cooling May 20041 Product Features Model IG Indirect Gas-Fired Make-Up

More information

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL The Kitchen Cool by Hood Depot is a conditioned make up air unit design with flexibility, form and function kept in mind. Our unit offers a variety of configurations that allow the customer to customize

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

GRILLE, REGISTER AND DIFFUSER SCHEDULE

GRILLE, REGISTER AND DIFFUSER SCHEDULE ROOFTOP UNIT SCHEDULE (NATURAL GAS HEAT) MARK MANUFACTURER MODEL SUPPLY FAN COOLING COIL HEAT EXCHANGER MIN. MIN. MCA MOCP V/PH WEIGHT NOTES FAN CFM MIN ESP REFR. TH SH EAT LAT MIN. OUTPUT MIN. EFF. NOM.

More information

City of Duluth Festival Center 04/25

City of Duluth Festival Center 04/25 SECTION 230593 - TESTING, ADJUSTING, AND BALANCING FOR HVAC PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

VertiCool Aurora Engineering Guide

VertiCool Aurora Engineering Guide Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8

More information

WPH4 Product Specifications

WPH4 Product Specifications Up to 14.5 SEER, 8.0 HSPF PACKAGE HEAT PUMP 2 to 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION MODULAR AIR HANDLER MODEL: N*AH CONTENTS GENERAL... 1 INSPECTION... 2 REFERENCE... 2 LIMITATIONS... 2 LOCATION... 2 BLOWER/COIL ASSEMBLY UPFLOW AND HORIZONTAL INSTALLATIONS...

More information

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL SECTION 15910 SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) LISTED MODELS: 018-060 (3 PH) MODELS: 076 (3 PH) ISO 9001 Certified Quality

More information

Mechanical System Description

Mechanical System Description 1. Building Description: Mechanical System Description The building is a Type-1B construction, 9-levels, non-high rise building with 67 affordable family housing units. The first level of the structure

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

HVAC 101. H V A C S y s t e m s

HVAC 101. H V A C S y s t e m s H V A C 1 0 1 S y s t e m s Introduction & Overview Should you care? Mechanical System Types Components & operation Popular Application Key Issues and Design Considerations System Comparisons First Cost

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT 50HJQ-11SB 50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

Inspection Report. 1 Inspection Way Orlando, FL Prepared for: Wanda Figueroa Prepared by: ACF Home Inspections Inc

Inspection Report. 1 Inspection Way Orlando, FL Prepared for: Wanda Figueroa Prepared by: ACF Home Inspections Inc Inspection Report 1 Inspection Way Orlando, FL 32825 Prepared for: Wanda Figueroa Prepared by: Page 1 of 25 Needs Service Summary This summary is not the entire report. The complete report may include

More information