1 HTP-7-CDN TRADE PRICE BOOK EFFECTIVE DATE MAY 15, 2014 TABLE OF CONTENTS TERMS AND CONDITIONS OF SALE... 2 FREIGHT POLICY... 2 EXPLANATION OF RATINGS... 3 COMMERCIAL BOILERS GAS-FIRED KN SERIES (Water) RESIDENTIAL BOILERS GAS-FIRED HWX (Water)... 7 HVX (Water)... 7 VGX (Steam)... 8 HEATNET BRIDGE ADDRESSING WORKSHEET... 9 WARRANTIES TRANMERE DRIVE MISSISSAUGA, ONTARIO L5S 1L4 CANADA (905) FAX (905)

2 GENERAL TERMS AND CONDITIONS OF SALE All orders are subject to acceptance by the factory. No liability shall be incurred by Mestek Canada if manufacture or delivery is prevented or delayed by strikes, fi res, delays of carriers or other delays unavoidable or beyond its reasonable control or by inability to obtain materials. Prices quoted herein supersede all prior price lists and are subject to change without notice. Prices are TAXES EXTRA, any taxes which may be payable on the manufacture, sale or delivery of the merchandise covered by this price book will be billed to the buyer. An order for items which total less than $25.00 will be shown on the invoice at $25.00 minimum. PAYMENT: Terms are net 30. A fi nance charge of 1-1/2% per month shall be imposed for indebtedness for which payment is not received within 30 days. In the event Buyer does not pay within the terms of this agreement, all collection costs incurred by Manufacturer, including attorney and court costs, will be paid by Buyer. FREIGHT TERMS: Prices quoted herein are F.O.B. our Mississauga plant. Freight will be allowed as follows: Full freight allowed on single shipments of 40,000 lbs. or more. Freight not allowed on shipments under 40,000 lbs. Shipping weights supplied in the price book are approximate, for buyer s convenience only, and are not guaranteed. We reserve the choice of transportation facilities and shipping point. DELIVERY: Delivery to the initial carrier shall constitute delivery to the buyer. The seller s responsibility ceases upon delivery in good order to such carrier, and all merchandise is shipped at the buyer s risk. The buyer is urged to examine all deliveries before signing transportation receipts. If merchandise is visibly damaged, the buyer should insist that written confi rmation of the damage be noted on the freight bill by the agent of the carrier. If damage is discovered after unpacking, the carrier should be notifi ed at once so that inspection can be made and the claimed damage substantiated by the carrier. RETURN MATERIAL POLICY: No material, whether new, used or alleged defective, may be returned without prior written authorization from the company. New and used equipment of current manufacture may be returned, freight prepaid after written authorization has been received. In such cases, credit will be allowed, less 25% handling and/or inspection charges if the equipment is received free of shipping or other damage. When a defect occurs in the heat exchanger unit only, the complete boiler will not be accepted for return. Material arriving at Mestek Canada plants not properly tagged will be refused. PROCEDURE FOR OBTAINING AUTHORIZATION TO RETURN MATERIAL: The customer or Representative will request an Authorization to Return Material tag. A separate tag will be issued for each item returned. All information requested on the tag must be supplied, if applicable, in order that the request may be processed promptly. The original tag will be torn off and retained by the customer for his records. The remaining two copies will be returned to the factory, along with the returned material. WARRANTY CLAIMS: Claims made under warranty on equipment thereof manufacture by Mestek Canada after the warranty has expired will be considered on the basis of 6 month shelf time prior to the date of installation. Claims made on equipment of parts thereof manufactured by Mestek Canada after this time frame will only be considered after claimant furnishes notarized bill of sales showing that the date of installation was within the warranty period. LABOUR CLAIMS AND ALLOWANCES: As specifi ed in the limited warranty, no labour allowances will be made for the replacement of warranty materials claimed defective. FREIGHT POLICY FULL FREIGHT ALLOWED TRUCKLOAD SHIPMENTS (Units Only) Shipping & Handling Charges Per Order and Ship to Location Net Value Single / Combined Order Zone 1 Zone 2 Zone 3 Full Freight Allowed at $100,000 $110,000 $125,000 Zone Breakdown ON, QC SK, MB BC, AB 2

3 EXPLANATION OF RATINGS BOILERS RATING CSA INPUT Firing rate in BTU/hr. for atmospheric gas boilers based on CSA certifi cation test procedures. AHRI Input Firing rate in gallons per hour of oil or BTU/hr. of gas in accordance with Hydronics Institute test procedures. DOE Heating Capacity Heat output of the boiler based on standard test procedures prescribed by the United States Department of Energy. Applies to boilers under 300,000 BTU/hr. input. CSA Gross Output Heat output of the boiler based on tests conducted at the CSA Laboratory. Applies to atmospheric gas boilers with inputs of 300,000 BTU/hr. and over. AHRI Gross Output Heat output of the boiler based on tests conducted in accordance with Hydronics Institute procedures. Applies to oil, gas and gas-oil boilers with power burners when input is 300,000 BTU/hr. and over. NET AHRI Ratings The DOE heating capacity, CSA gross output, or AHRI gross output less deductions for piping and pickup. The amount of the deduction is determined by the AHRI Testing and Rating Code for Heating Boilers. Certified Ratings Ratings when boiler is fi red with special burners and/or under fi ring conditions other than stipulated by the AHRI code. SELECTING THE BOILER Boilers should be selected based on the Net AHRI rating when piping and pickup factors are considered normal. Net AHRI ratings are shown in BTU/hr. for water and steam and in square feet of steam. To select residential boilers for gravity hot water systems, fl oor panel systems, hot water or steam systems with larger than normal piping and pickup factors, and replacement boilers on hot water or steam systems with old style radiation and large piping, see chart below for piping pickup factors. ASME CONSTRUCTION All Advanced Thermal Hydronics boilers meet the requirements of the ASME boiler and pressure Vessel Code, Section IV, Heating Boilers. The Net AHRI Steam Ratings shown are based on a piping and pickup allowance as follows: Net AHRI Piping Net AHRI Piping Steam Rating and Steam Rating and 1000 BTU Pickup Factor 1000 BTU Pickup Factor 22.5 thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru thru and over The Net AHRI Water Ratings shown are based on an allowance of 1.15 for piping and pickup. The manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements. 3

4 KN SERIES KN-2 & KN-4 GAS-FIRED MODULATING BOILERS (NATURAL GAS/PROPANE) CRN M1500.5C Boiler Model KN-2 KN-4 Part Number Nat. Gas/LP BM-1030 BM-1032 Input CSA Input MBH Output *Standard 30 PSI 100 PSI max allowed. DOE AFUE 92.7% 92.7% Relief Valve Press 30 PSI* 30 PSI* Ship Wt. Lbs Trade Price $6,845 $11,875 ENERGY STAR RELIEF VALVE AND ACCESSORY PACKAGE (No Charge when ordered with Boiler) Boiler Model Part Number 30 PSI 50 PSI KN KN PSI 100 PSI KN KN KN-2, KN-4 STANDARD FEATURES Condensing Boiler Air/Fuel Coupled Commercial Grade Cast Iron Sections Durable Insulated Jacket Direct Vent On-Board Recirc. Pump Unique Down Fire Design Low Nox Emissions Comprehensive SmartCycle Control Capable of Self Adjust for Altitude Firing Single or Multiple Boilers Reusable Air Filter IAR Indoor Air Reset (Up to 8 Zones with Direct Spark Ignition Domestic Hot Water Priority) Flame Rod Rectifi cation Opt. Outdoor Air Reset Steel Base Metal Mesh Burner Condensate Trap Communication Module - Modbus Factory Fire Tested Communication Cable 25' Return/Supply Boiler Sensor (10K) 3" w.c. Minimum Gas Pressure T & P Gauge 5:1 Modulation Air Vent B & G #98 OPTIONAL KN ACCESSORIES Order code Description Trade Price Well 2 1/2"...$ Outdoor Sensor w/enclosure (one required for each master boiler) Common Header Supply Sensor 10K (less well) (one required for each master boiler) BACNet & LonWorks for KN-2 & 4: Protocarrier BACNet IP Protocessor*... 1, BACNet MSTP Protocessor*... 1, LonWorks Protocessor*... 1, Communications Cable 25' *Must complete HeatNet Bridge Addressing Worksheet on page 9. 4

5 KN-SERIES GAS-FIRED MODULATING BOILERS CRN M1500.5C Boiler Model Nat. Gas LP Gas Dual Fuel Input MBH CSA Output MBH Ship WT. (Lbs) Trade Price KN-6* BM-1082 BM $20,685 KN-6* BM ,360 KN-6* Knockdown BM-1084** ,265 KN-10* BM-1086 BM , ,085 KN-10* BM , ,760 KN-10* Knockdown BM-1088** ,665 KN-16 BM-1036 BM ,600 1, ,665 KN-16 BM ,600 1, ,340 KN-16 Knockdown BM-1034** ,245 KN-20 BM-1075 BM ,999 1, ,525 KN-20 BM ,999 1, ,200 KN-20 Knockdown BM-1077** ,105 KN-26 BM-1038*** BM-1039*** 2,600 2, ,630 KN-26 BM ,600 2, ,305 KN-26 Knockdown BM-1035** ,210 RELIEF VALVE AND ACCESSORY PACKAGE (No Charge when ordered with Boiler) Boiler Model Part Number 30 PSI 50 PSI KN KN KN KN KN KN PSI 100 PSI KN KN KN KN KN KN KN-30 BM-1048*** BM-1049*** 3,000 2, ,475 KN-30 BM ,000 2, ,150 KN-30 Knockdown BM-1033** ,055 * Flow Switch only applicable on applications of 30 gpm or higher. Less than 30 gpm order fl ow switch to ship loose for fi eld installation in a 2" tee. Note on order if less than 30 gpm. ** Must specify NG or LP. *** Must specify voltage 208V or 230V. CSD-1 compliance must be specified on purchase order... If a CSD-1 data report is required order using part number 22Z-CSD1 at $25 NET per unit. Please note required state at time of order placement. N/C 5

6 KN-6, KN-10, KN-16, KN-20, KN-26 and KN-30 STANDARD FEATURES Factory assembled cast iron heat exchanger Insulated jacket Air fuel coupled with modulating Dungs gas valve Flame safeguard control (Honeywell RM7800) Interrupted spark ignition CSD-1 compliant gas train CSD-1 compliant LWCO Full linear modulation Cabinet mounted electrical components Vacuum fl uorescent operating status display Flue adapter with analyzer probe hole Metal mesh burner Flow switch mounted Manual reset high limit Safety pressure relief valve (must specify) UV fl ame rectifi cation Condensate drain with fi ttings Variable speed blower Temperature pressure indicator Air vent TACO 409 High gas pressure switch (KN-26/30) HeatNet integrated boiler management system Communication board Return header sensor Communication card which allows for: Boiler to boiler communications Firmware updates Connections to building management systems using Modbus protocol BOILER CONTROL STANDARD FEATURES Outlet supply sensor Modbus protocol for building management system communications OPTIONAL KN ACCESSORIES Order code Description Trade Price High Gas Pressure Switch (Manual Reset)...$ Keyboard Display Module Honeywell S7800A CONTROL Outdoor Sensor w/enclosure (one required for each master boiler) Common Header Supply Sensor 10K (less well) (one required for each master boiler) /2" Well " Well Strap-on Sensor (10K) USB Cable for HeatNet revisions BACnet IP ProtoCessor*... 1, BACnet MSTP ProtoCessor*... 1, LonWorks ProtoCessor*... 1, Metasys N2... 1,512 *Must complete HeatNet Bridge Addressing Worksheet on page 9. ISOLATION VALVE WIRING - Mounted BM KN BM KN BM KN BM KN-16, 26 & FREEZE PROTECTION KITS: (Includes Damper, Relays and Factory Wired Damper Harness) BM " Damper Kit BM " Damper Kit BM " Damper Kit BM " Damper Kit BM " Damper Kit VOLTAGE OPTIONS: Pump Contactor (whirlwind only) Option Part Number Size List Add Boiler Voltage Package (available mounted ONLY) 208/ V 1PH w/.75hp Pump Starter BM $580 w/ 1HP Pump Starter BM $ / V 3PH BM $390 w/.75hp Pump Starter BM $855 w/ 1HP Pump Starter BM $ / V 3PH w/ 1HP Pump Starter BM $550 w/ 1.5HP Pump Starter BM $605 w/ 2HP Pump Starter BM $630 Boiler Voltage Package (available mounted or shipped loose) 600V 3PH BM-1115 $1,895 w/.75hp Pump Starter BM $2,365 w/ 1HP Pump Starter BM $2, V 3PH BM $2,875 w/ 1HP Pump Starter BM $3, w/ 1.5HP Pump Starter BM $3,525 w/ 2HP Pump Starter BM $3,525 6

7 HWX/HVX SERIES STANDING PILOT/SPARK IGNITED ATMOSPHERIC GAS-FIRED/WATER BOILER 70 to 195 MBH Input; 30 psi ASME HWX Boiler Model HWX-70 HWX-105 HWX-140 HWX-175 HWX-195 Natural Gas/LP Ratings (MBH) Net AHRI A.G.A. Input Heat Cap. Rating (MBH) *A.F.U.E. % *A.F.U.E. listed with intermittent ignition and vent damper. Intermittent Pilot w/circulator Nat. Gas BM BM BM BM BM Prop. Gas BM BM BM BM BM Trade Price $2,345 2,513 2,950 3,179 3,496 Ship Wt. (Lbs.) HVX Natural Gas/LP Ratings (MBH) Boiler Model A.G.A. Input Heat Cap. HVX-70 HVX-105 HVX-140 HVX *A.F.U.E. listed with intermittent ignition. Net AHRI Rating (MBH) *A.F.U.E. % Intermittent Ignition Nat. Gas Prop. Gas Trade Price BM BM BM BM BM BM BM BM $2,255 2,389 2,604 2,900 Ship Wt. (Lbs.) STANDARD EQUIPMENT Completely packaged and wired gas hot water boiler. Cast iron sections, steel push nipples Deluxe insulated metal jacket with removable front panel Burner base with high temperature insulation board and burner tubes Integral fl ue collector and draft diverter A.S.M.E. pressure relief valve Taco 007 circulator Temperature pressure gauge Brass hose end drain valve Automatic vent damper (HWX) Safety spill switch (HWX) Flame rollout safety switch High limit and control center Pressure Switch (HVX) Inducer (HVX) Honeywell intermittent ignition 7

8 VGX SERIES PACKAGED GAS-FIRED STEAM BOILER 74 to 238 MBH D.O.E. Heating Capacity - Natural or Propane Gas VGX AHRI Intermittent Pilot Water Approx. Boiler A.G.A. D.O.E. Net Ratings Conent Shipping Nat. Gas L.P. Gas Trade Steam Weight **A.F.U.E. Model Input Capacity Sq. Ft. MBH Price (Gallons) (LBS) % VGX BM-9374 BM-9381 $2, VGX BM-9375 BM , VGX BM-9376 BM , VGX BM-9377 BM , VGX BM-9378 BM , VGX BM-9379 BM , VGX BM-9380 BM , **A.F.U.E. all based on D.O.E. intermittent pilot/vent damper NG. STANDARD EQUIPMENT Cast iron sections, assembled and tested. Factory assembled with slide-in burner tray with 24 volt combination gas valve and manifold with burner orifi ces. Deluxe insulated metal jacket Integral fl ue collector Automatic vent damper Stainless steel burner tubes Skim tapping for easy cleaning Drain valve Hydrolevel probe LWCO (mounted & wired). Pressure control Gauge glass and fi ttings Pressure gauge ASME safety relief valve Blocked vent shut-off switch Flame roll-out shut-off switch 8

9 HeatNet Bridge Addressing Worksheet Please fi ll out a separate form for each HeatNet bridge. Every HeatNet bridge comes from the factory with the default address settings (shown in parenthesis) listed in section 2. The bridge can be programmed in the field by following instructions, which can be downloaded, from the product web sites and This requires some computer and networking experience. The bridges can also be programmed at the factory by filling out the information in section 2 of this worksheet. 1. Customer Information Rep Name: Date Customer Name: Order #: Contact Name 1 : Location/Job: Contact Phone 1 : Contact Factory addressing IS NOT required. 4.4 N2 Factory Addressing IS required (section 2 MUST be completed). 1 Contact is an Engineering contact that will be able to provide technical data for the application. 2. Product: KN Series Futera Series Smith 2.1 Model: (i.e. KN2, KN4, etc) 3. Protocol (Choose one of the following protocols) BACnet MSTP BACnet IP LonWorks N2 4. Addressing Please complete one of the following sections based on required protocol. Default values are shown in parenthesis. 4.1 BACnet MSTP BACnet MAC Address (11): (1-127: Master, : Passive Member) 2 BACnet Device Instance (11): Baud Rate (38400): choose one BACnet IP IP Address ( ): IP Subnet Mask ( ): IP Port (47808): ( ) DHCP Client (no): no yes BACnet Network Number (5): ( ) BACnet MAC Address (11): BACnet Device Instance (11): 4.3 LonWorks The following parameters are usually set by the commissioning software. Factory programming (of domain, subnet, and node) should only be needed under very special circumstances. Domain: Subnet: Node: 2 Passive members do not respond to BACnet who is messages and thus cannot be automatically discovered. 3 Available on version 2+ BACnet bridges. A HeatNet Master-Member system (network) can contain up to 16 boilers. The HeatNet N2 Bridge is normally attached to the master and can provide most data points that the master periodically reads from each member. Per the N2 specification; baud=9600, data bits=8, stop bits=1, and parity=none. The N2 protocol is limited to 255 data points of each type. For this reason, the HeatNet N2 Bridge is configured to act like 16 different N2 devices. Each device represents a different boiler. The Master/Standalone boiler must always be enabled, but in order to conserve N2 addresses members must be specifically enabled. Please complete the following table: Boiler Enabled Address (1-255) Master/Standalone: (default = 101) Member 2: (default = 102) Member 3: (default = 103) Member 4: (default = 104) Member 5: (default = 105) Member 6: (default = 106) Member 7: (default = 107) Member 8: (default = 108) Member 9: (default = 109) Member 10: (default = 110) Member 11: (default = 111) Member 12: (default = 112) Member 13: (default = 113) Member 14: (default = 114) Member 15: (default = 115) Member 16: (default = 116) Customer PO#: Factory Order #: (internal use only) 9

10 KN Series Water Boiler Limited Warranty One-Year Warranty The Manufacturer warrants to the original owner at the original installation site that the KN-Series modulating water boiler ( Product ) will be free from defects in material and workmanship for one (1) year from the date of installation or eighteen (18) months from the date of shipment from the factory whichever comes fi rst. If upon examination by the manufacturer the product is shown to have a defect in material or workmanship during the warranty period, the manufacturer will repair or replace, at its option that part of the product, which is shown to be defective. Ten-Year Warranty The manufacturer further warrants to the original owner at the original installation site that the products Heat Exchanger (Cast Iron Block) will be free from defects from condensate corrosion and in material and workmanship for a period of ten (10) years (non prorated) from the date of shipment from the factory. If upon examination by the manufacturer the product is shown to have a defect in material or workmanship during the warranty period, the manufacturer will repair or replace, at its option the Heat Exchanger of the product, which is shown to be defective. Twenty-One Year Thermal Shock Warranty The manufacturer further warrants to the original owner at the original installation site that the products (Cast Iron Sections) will be warranted for twenty-one (21) years against thermal shock when the boiler is installed as a closed loop hot water boiler. This warranty will cover damage due to thermal shock, such as leaks to the cast iron sections from cracks from thermal shock. This warranty does not cover damage due to corrosion, scaling, sooting or to improper installation or operation the inlet and outlet water temperature differential across the boiler cannot exceed 100 degrees F. Water quality is important. As per ASME recommendations, dissolved solids must be less than 200 ppm. Also, ph levels must be in the range. Failure to follow these guidelines will void the warranty. This Limited Warranty does not Apply: (a) If the product has been subjected to misuse or neglect, has been accidentally or intentionally damaged, has not been installed, maintained or operated in accordance with the furnished written instructions, or has been altered or modifi ed in anyway by any unauthorized person. (b) To any expenses, including labor or material, incurred during the removal or reinstallation of the product or parts thereof. (c) To products which were not installed and or serviced by a qualifi ed contractor and or serviceman. (d) To burners, jackets, controls and other auxiliary equipment furnished by the manufacturer, but manufacturerd by others. Any warranties for such items shall be limited to those warranties offered by the original equipment manufacturer. (e) To any workmanship by any installer of the product. This limited Warranty is Conditional Upon: (a) Shipment, to the manufacturer, of that part of the product thought to be defective. Goods may only be returned with prior written approval of the manufacturer. All returns must be freight prepaid. (b) Determination in the reasonable opinion of the manufacturer that there exists a defect in material or workmanship. Repair or replacement of any part under this Limited warranty shall not extend the duration of the warranty with respect to such repaired or replaced part beyond the stated warranty period. THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EITHER EXPRESSED OR IMPLIED, AND ALL SUCH OTHER WARRANTIES, INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS LIMITED WARRANTY. IN NO EVENT SHALL THE MANUFACTURER BE LIABLE IN ANY WAY FOR ANY CONSEQUENTIAL, SPECIAL, OR INCIDENTAL DAMAGES OF ANY NATURE WHATSOEVER, OR FOR ANY AMOUNTS IN EXCESS OF THE SELLING PRICE OF THE PRODUCT OR ANY PARTS THEREOF FOUND TO BE DEFECTIVE. THIS LIMITED WARRANTY GIVES THE OWNER AT THE ORIGINAL INSTALLATION SITE SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS, WHICH MAY VARY BY EACH JURISDICTION. 10

11 LIFETIME LIMITED WARRANTY Residential Cast Iron Water Boilers First Through Tenth Year The Manufacturer warrants to the original owner at the original installation site that the cast iron sections of the Residential Cast Iron Water Boilers (the Product ) will be free from defects in material or workmanship for ten (10) years from the date of installation. If upon examination by the Manufacturer the Product is shown to have a defect in material or workmanship during the warranty period, the Manufacturer will repair or replace, at its option, that part of the Product which is shown to be defective. Eleventh Year and Above The Manufacturer warrants that the cast iron sections of its residential cast iron water boilers will remain free of defects in material or workmanship under normal usage for the lifetime of the original owner at the original installation site. Should any sections be found to be defective, the Manufacturer will repair or replace, at its option, the original cast iron sections upon the payment of a proportionate charge based on the time the defective section was in service. The proportionate charge will be equal to the appropriate percentage of the trade price of the section at the time the warranty claim is made, determined as follows: Year & Above % of Trade Price This limited warranty does not apply: (a) if the Product has been subjected to misuse or neglect, has been accidentally or intentionally damaged, has not been installed, maintained or operated in accordance with the furnished written instructions, or has been altered or modifi ed in any way. (b) to any expenses, including labor or material, incurred during removal or reinstallation of the Product or parts thereof. (c) to any other cast iron parts of the boiler. (d) to burners, jackets, controls, and other auxiliary equipment furnished by the Manufacturer, but manufactured by others. Any warranties for such items shall be limited to those warranties offered by the original equipment manufacturer. (e) to damage as a result of settlement, distortion, collapse, or cracking of any foundation area, beams or pipes surrounding the Product. (f) to any workmanship of any installer of the Product; or to Products installed outside the continental United States or Canada. This limited warranty is conditional upon: (a) shipment, to the Manufacturer, of that part of the Product thought to be defective. Goods can only be returned with prior written approval from the Manufacturer. All returns must be freight prepaid. (b) determination, in the reasonable opinion of the Manufacturer, that there exists a defect in material or workmanship (c) the residential water boiler having been installed in a single family or two family residential dwelling. Repair or replacement of any part under this Limited Warranty shall not extend the duration of the warranty with respect to such repaired or replaced part beyond the stated warranty period. THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EITHER EXPRESS OR IMPLIED, AND ALL SUCH OTHER WARRANTIES, INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS LIMITED WARRANTY. IN NO EVENT SHALL THE MANUFACTURER BE LIABLE IN ANY WAY FOR ANY CONSEQUENTIAL, SPECIAL, OR INCIDENTAL DAMAGES OF ANY NATURE WHATSOEVER, OR FOR ANY AMOUNTS IN EXCESS OF THE SELLING PRICE OF THE PRODUCT OR ANY PARTS THEREOF FOUND TO BE DEFECTIVE. THIS LIMITED WARRANTY GIVES THE ORIGINAL OWNER OF THE PRODUCT SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS WHICH MAY VARY BY EACH JURISDICTION. 11

12 LIMITED WARRANTY Residential Cast Iron Steam Boilers One Year Warranty The Manufacturer warrants to the original owner at the original installation site that the Residential Cast Iron Steam Boiler (the Product ) will be free from defects in material or workmanship for one (1) year from date of installation. If upon examination by the Manufacturer the Product is shown to have a defect in material or workmanship during the warranty period, the Manufacturer will repair or replace, at its option, that part of the Product which is shown to be defective. Ten Year Warranty The Manufacturer further warrants to the original owner at the original installation site that the Product s cast iron sections will be free from defects in material or workmanship for ten (10) years from the date of shipment from the factory. If upon examination by the Manufacturer a cast iron section is shown to have a defect in material or workmanship during the warranty period, the Manufacturer will repair or replace, at its option, that part of the Product which is shown to be defective. This limited warranty does not apply: (a) if the Product has been subjected to misuse or neglect, has been accidentally or intentionally damaged, has not been installed, maintained or operated in accordance with the furnished written instructions, or has been altered or modifi ed in any way. (b) to any expenses, including labor or material, incurred during removal or reinstallation of the Product or parts thereof. (c) to any other cast iron parts of the boiler. (d) to burners, jackets, controls, and other auxiliary equipment furnished by the Manufacturer, but manufactured by others. Any warranties for such items shall be limited to those warranties offered by the original equipment manufacturer. (e) to damage as a result of settlement, distortion, collapse, or cracking of any foundation area, beams or pipes surrounding the Product. (f) to any workmanship of any installer of the Product; or to Products installed outside the continental United States or Canada. This limited warranty is conditional upon: (a) shipment, to the Manufacturer, of that part of the Product thought to be defective. Goods may only be returned with the prior written approval of the Manufacturer. All returns must be freight prepaid. (b) determination in the reasonable opinion of the Manufacturer that there exists a defect in material or workmanship. Repair or replacement of any part under this Limited Warranty shall not extend the duration of the warranty with respect to such repaired or replaced part beyond the stated warranty period. THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EITHER EXPRESS OR IMPLIED, AND ALL SUCH OTHER WARRANTIES, INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS LIMITED WARRANTY. IN NO EVENT SHALL THE MANUFACTURER BE LIABLE IN ANY WAY FOR ANY CONSEQUENTIAL, SPECIAL, OR INCIDENTAL DAMAGES OF ANY NATURE WHATSOEVER, OR FOR ANY AMOUNTS IN EXCESS OF THE SELLING PRICE OF THE PRODUCT OR ANY PARTS THEREOF FOUND TO BE DEFECTIVE. THIS LIMITED WARRANTY GIVES OWNER OF THE INSTALLATION SITE SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS WHICH MAY VARY BY EACH JURISDICTION TRANMERE DRIVE MISSISSAUGA, ONTARIO L5S 1L4 CANADA (905) FAX (905)

FTIIIC-10. Domestic Hot Water Heaters and Boilers

FTIIIC-10. Domestic Hot Water Heaters and Boilers FTIIIC-10 Domestic Hot Water Heaters and Boilers Full Modulation, High Efficiency Hot Water Supply and Hydronic Heating Boilers The gas-fired Futera III brings the field-proven performance of Futera Series

More information

Domestic Hot Water Heaters and Boilers FTIIIC-6

Domestic Hot Water Heaters and Boilers FTIIIC-6 Domestic Hot Water Heaters and Boilers FTIIIC-6 Full Modulation, High Efficiency Hot Water Supply and Hydronic Heating Boilers The gas-fired Futera III brings the field-proven performance of Futera Series

More information

FXLF-9. High Efficiency Water Heaters and Boilers

FXLF-9. High Efficiency Water Heaters and Boilers FXLF-9 High Efficiency Water Heaters and Boilers Small Steps Big Plans Today s boiler and water heater markets demand high efficiency in smaller spaces both mechanical room space and equipment size. RBI

More information

BEACON/MORRIS RBD SERIES INFRARED RADIANT HEATER

BEACON/MORRIS RBD SERIES INFRARED RADIANT HEATER RBDS-1 RBD SERIES CERAMIC HEATERS NATURAL GAS (Check One) PROPANE GAS EQUIPMENT USED: ACCESSORIES: Chain Mounting Kit: Thermostat: Gas Pressure Regulator: Parabolic Extension: Gas Shut-Off Valve: Reverb

More information

BTUC-4 TUBULAR GAS-FIRED UNIT HEATERS

BTUC-4 TUBULAR GAS-FIRED UNIT HEATERS BTUC-4 TUBULAR GAS-FIRED UNIT HEATERS Table of Contents Models BTU & BRU General Information 3 Performance and Dimensional Data 4, 5 Model Number Description 6 Model BST General Information 7 Performance

More information

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s) Furnish and install as shown on AERCO International plans and operation and maintenance manuals, with all applicable codes and authorities having local, state and federal jurisdiction, Benchmark Series

More information

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job SERIES Commercial, Forced Draft, Hot Water or Steam Boiler Sizes from to,8 MBH output The right fit for any commercial job The Series is built to handle any installation - businesses, institutions, apartments,

More information

INFRARED RADIANT HEATERS

INFRARED RADIANT HEATERS IRH-1R INFRARED RADIANT HEATERS High and Low Intensity RSU SERIES Unit is shown rotated at a 45 angle. RSD SERIES HIGH INTENSITY INFRARED HEATERS RSD Series Ceramic Heaters Special Honeycomb Tile Design

More information

First Year Limited Warranty for Residential Use Condensing Water Boilers (Includes Heat Exchanger and Component Parts)

First Year Limited Warranty for Residential Use Condensing Water Boilers (Includes Heat Exchanger and Component Parts) THIS GIVES THE ORIGINAL PURCHASER ONLY SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER LEGAL RIGHTS WHICH VARY FROM STATE-TO-STATE AND -TO- Our Warranty By this warranty statement ( Limited Warranty

More information

FXLF-4. High Efficiency Water Heaters and Boilers

FXLF-4. High Efficiency Water Heaters and Boilers FXLF-4 High Efficiency Water Heaters and Boilers Efficient Power, Sized to Your Vision The Futera XLF is designed with 5-to-1 turndown, up to 88% efficiency, and backed by RBI reliability and ease of service.

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS MVB, TYPE H - MODELS 503A-2003A SUGGESTED SPECIFICATIONS Catalog No.: 2000.932C Effective: 04-01-14 Replaces: 07-15-13 DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

PB HEAT, LLC TRADE PRICE LIST EFFECTIVE JUNE 1, 2018 P-18

PB HEAT, LLC TRADE PRICE LIST EFFECTIVE JUNE 1, 2018 P-18 PB HEAT, LLC TRADE PRICE LIST EFFECTIVE JUNE 1, 2018 P-18 Table of Contents Table of Contents.................................................1 Product Selection Guide............................................2

More information

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS FTIIC-6 LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS Futera II Series boilers and water heaters are also available with corrosion-resistant, brushed stainless steel jacket. Ideal

More information

Peerless Boilers. Series MI. Residential Gas Boilers

Peerless Boilers. Series MI. Residential Gas Boilers Peerless Boilers Series MI Residential Gas Boilers Hard work and dedication by skilled employees have made us one of today s top cast iron boiler manufacturers. From the beginning, our main priority has

More information

HIGH EFFICIENCY GAS-FIRED, UNIT HEATER LIST PRICES

HIGH EFFICIENCY GAS-FIRED, UNIT HEATER LIST PRICES PRICE SHEET: NXPS-3 EFFECTIVE: July 1, 2018 SUPERSEDES: NXPS-2 HIGH EFFICIENCY GAS-FIRED, UNIT HEATER LIST PRICES ITEM PAGE HU Series Unit Number Description...2 HU Series...3 Options...4 Options - Accessories,

More information

CONDENSING WATER BOILERS. (Models VLT , Q VX ,

CONDENSING WATER BOILERS. (Models VLT , Q VX , Our Warranty By this warranty statement ( Limited Warranty ), ECR International, Inc. ( ECR ) issues limited warranties from the date of installation of the applicable Dunkirk Boiler ( Boiler ) to the

More information

KN2/4 SERIES MASTER SPECIFICATION

KN2/4 SERIES MASTER SPECIFICATION KN2/4SP4-2 SECTION 23 52 23 SAMPLE SPECIFICATION FOR HYDROTHERM KN-2 and KN-4 SERIES BOILERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General

More information

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists. gas-fired water boiler Manual Replacement parts Replacement parts must be purchased through a local Weil-McLain distributor. When ordering, specify boiler model and size and include description and part

More information

CONDENSING, MODULATING, HOT WATER SUPPLY, POOL, AND HYDRONIC HEATING BOILERS

CONDENSING, MODULATING, HOT WATER SUPPLY, POOL, AND HYDRONIC HEATING BOILERS FFC-2 CONDENSING, MODULATING, HOT WATER SUPPLY, POOL, AND HYDRONIC HEATING BOILERS The gas-fired Futera Fusion TM now brings the field-proven performance of Futera III Modulation boilers and water heaters

More information

Now Available with PVC & Polypropylene Vent Configurations

Now Available with PVC & Polypropylene Vent Configurations FFC-3R Now Available with PVC & Polypropylene Vent Configurations Fully Condensing Ultra Efficient The gas-fired Futera Fusion brings the field-proven performance of Futera Series boilers and water heaters

More information

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh HEATERS / BOILERS GWB8-E Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 065 July 06 Supersedes September 05 AFUE up to 83.9% Heating Input 50,000 to 99,000 Btuh MODEL NUMBER IDENTIFICATION

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS MVB, TYPE H - MODELS 2503-4003 SUGGESTED SPECIFICATIONS Catalog No.: 2000.934A Effective: 04-01-14 Replaces: 06-01-13 DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

SERIES 19A. mith PRESSURIZED WET BASE

SERIES 19A. mith PRESSURIZED WET BASE SERIES 19A mith series19a BOILER/BURNER PRESSURIZED WET BASE UNIT series 19A STANDARD EQUIPMENT All s Cast iron wet-base sections tested for 80psi. Insulated metal jacket Cast iron smokehood with integral

More information

Hubbell NX500 High Efficiency Gas Condensing Water Heater

Hubbell NX500 High Efficiency Gas Condensing Water Heater Hubbell NX500 High Efficiency Gas Condensing Water Heater Suggested Specification Part I - General Part II - Product Part III - Installation Project Name: Location: Engineer: Contractor: I. GENERAL Rep:

More information

KN-SERIES GAS-FIRED DIRECT VENT CAST IRON BOILERS KN-6 KN-10 KN-20

KN-SERIES GAS-FIRED DIRECT VENT CAST IRON BOILERS KN-6 KN-10 KN-20 KN-Series boilers by HydroTherm may just be the biggest break-through in heating technology since fire itself. Think that s an overstatement? Consider this the KN-Series combines high 99% efficiency and

More information

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E WATER HEATERS / BOILERS -E PRODUCT SPECIFICATIONS Gas-Fired Steam Boiler Bulletin No. 20653 September 202 Supersedes Bulletin No. 20263 AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh MODEL NUMBER

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS MVB, TYPE H - MODELS 504A-2004A SUGGESTED SPECIFICATIONS Catalog No.: 2000.933C Effective: 06-25-15 Replaces: 12-21-09 DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

Service Parts, Kits and Accessories

Service Parts, Kits and Accessories The parts identification guides on the following pages have been designed to give a quick reference to component parts used on pilot ignition agricultural building heaters. The guides identify components

More information

WIRING DIAGRAMS R410A MODELS PAC 2OAC/2OACH CAC OWC PWC

WIRING DIAGRAMS R410A MODELS PAC 2OAC/2OACH CAC OWC PWC WIRING DIAGRAMS R410A MODELS 2OAC/2OACH PAC CAC PWC OWC WIRING 02172017 TABLE OF CONTENTS PAGE 2OACH Deluxe Portable Air-cooled Heat Pump Electronic Controller... 2-3 Piping Schematic... 4 Single Phase

More information

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh HEATERS / BOILERS GWB8-E PRODUCT SPECIFICATIONS Gas-Fired Hot Water Boiler Bulletin No. 065 September 0 Supersedes Bulletin No. 06 AFUE up to 83.9% Heating Input 50,000 to 99,000 Btuh MODEL NUMBER IDENTIFICATION

More information

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS XTHERM, TYPE WH - MODELS 1005A- 2005A Catalog No.: 3500.801 Effective: 11-15-14 Replaces: NEW PART 1 - GENERAL 1.1 SUMMARY DIVISION 23 34 36.29 COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

More information

Project Name: Location: Engineer: Contractor: I. GENERAL

Project Name: Location: Engineer: Contractor: I. GENERAL Part I - General Part II - Product Part III - Installation Project Name: Location: Engineer: Contractor: I. GENERAL I. PRODUCT Rep: Date: A. Supply and install modulating and condensing boiler(s) as specified

More information

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS MVB, TYPE WH - MODELS 503A-2003A SUGGESTED SPECIFICATIONS Catalog No.: 3500.952C Effective: 06-25-15 Replaces: 12-22-09 DIVISION 23 34 36.29 COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

More information

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh WATER HEATERS / BOILERS COWB3 Oil-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 0654 March 08 Supersedes September 05 AFUE up to 85.% Heating Input 05,000 to 45,000 Btuh MODEL NUMBER IDENTIFICATION

More information

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES P R O D U C T S P E C I F I C AT I O N S W A T E R H E A T E R S / B O I L E R S CONSERVATOR Gas-Fired Steam Boiler Bulletin No. 20263 October 200 Supersedes September 2008 AFUE up to 82.7% Heating Input

More information

KN-SERIES MASTER SPECIFICATION

KN-SERIES MASTER SPECIFICATION KNSP4-8R KN-6, KN-10, KN-16, KN-20, KN-26, KN-30 SECTION 23 52 16 CONDENSING HIGH EFFICIENCY CAST IRON KN-SERIES BOILERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the

More information

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit January 2008 WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit Installation Operation Maintenance The units are designed for permanent up flow, counter flow, or horizontal left or right airflow

More information

GB Condensing Gas Boiler

GB Condensing Gas Boiler Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus GB162/100 wall-hung condensing hot water boiler(s), suitable for

More information

TWIN-FLOIII HEATER INSPECT THE SHIPMENT IMMEDIATELY WHEN RECEIVED TO DETERMINE IF ANY DAMAGE HAS OCCURRED DURING SHIPMENT.

TWIN-FLOIII HEATER INSPECT THE SHIPMENT IMMEDIATELY WHEN RECEIVED TO DETERMINE IF ANY DAMAGE HAS OCCURRED DURING SHIPMENT. TFII-11 Beacon/Morris TWIN-FLOIII HEATER INSTALLATION INSTRUCTIONS TYPES K, W, & F ATTENTION: READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE, OR SERVICE THE BEACON MORRIS TWIN-FLO

More information

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater Part I - General Part II - Product Part III - Installation Project Name: Location: Engineer: Contractor: I. GENERAL Rep: A. Supply and install modulating and condensing boiler(s) as specified herein. Date:

More information

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater Part I - General Part II - Product Part III - Installation Project Name: Location: Engineer: Contractor: I. GENERAL Rep: Date: A. Supply and install modulating and condensing boiler(s)/water heater(s)

More information

AFUE 95% Heating Input 50,000 to 200,000 Btuh

AFUE 95% Heating Input 50,000 to 200,000 Btuh PRODUCT SPECIFICATIONS WATER HEATERS / BOILERS GWM-IE Gas-Fired, Modulating, Condensing, Wall Hung Hot Water Boiler Bulletin No. 210650 March 2018 Supersedes December 2015 AFUE 95% Heating Input 50,000

More information

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater Part I - General Part II - Product Part III - Installation Project Name: Location: Engineer: Contractor: I. GENERAL Rep: Date: A. Supply and install modulating and condensing boiler(s)/water heater(s)

More information

Phantom-X 399C/500C. Residential High Efficiency Gas Boilers PHNTM399C, PHNTM500C Submittal Sheet. Wholesaler Job Name Mechanical Contractor

Phantom-X 399C/500C. Residential High Efficiency Gas Boilers PHNTM399C, PHNTM500C Submittal Sheet. Wholesaler Job Name Mechanical Contractor PHNTM Floor Standing Heating s Phantom-X 399C/500C Residential High Efficiency Gas s PHNTM399C, PHNTM500C Submittal Sheet Wholesaler Job Name Mechanical Contractor Number Gas Type BTU/hr INPUT BTU/hr OUTPUT

More information

23 11/32 [593] Ø8 AIR INLET [203] 6 5/8 [168] 44 3/4 [1137] TOP VIEW ASUB-31 REV. B 38 11/16 [983] 3 NPT BOILER OUTLET WIRING CONNECTIONS 1 NPT 1 NPT

23 11/32 [593] Ø8 AIR INLET [203] 6 5/8 [168] 44 3/4 [1137] TOP VIEW ASUB-31 REV. B 38 11/16 [983] 3 NPT BOILER OUTLET WIRING CONNECTIONS 1 NPT 1 NPT CODE OPTIONS CSD-1 STANDARD 7 9/16 [192] 23 11/32 [593] Ø8 AIR INLET [203] 44 3/4 [1137] TOP VIEW ASUB-31 REV. B 6 5/8 [168] 4 7/8 [124] 38 11/16 [983] 34 1/16 [865] 3 NPT BOILER OUTLET WIRING CONNECTIONS

More information

G315/6 Cast Iron Boiler

G315/6 Cast Iron Boiler Engineering Submittal Sheet Boiler Overview LISTED Engineering Specifications There shall be provided and installed G315-6 Buderus sectional cast iron hot water boiler(s), suitable for forced draft firing

More information

LGB COMMERCIAL GAS BOILER. Versatile combustion control systems. Made with Weil-McLain quality COMMERCIAL GAS BOILER APPLICATIONS INCLUDE:

LGB COMMERCIAL GAS BOILER. Versatile combustion control systems. Made with Weil-McLain quality COMMERCIAL GAS BOILER APPLICATIONS INCLUDE: www.weil-mclain.com COMMERCIAL GAS OILER Series Gas Water or Steam MH: 400-,860 Efficiency 85.% Net Load Range: Hot Water 80-, MH / Steam 975-7,40 Sq. Ft. COMMERCIAL GAS OILER APPLICATIONS INCLUDE: Apartment

More information

Commercial Boilers and Domestic Water Heaters APG-5

Commercial Boilers and Domestic Water Heaters APG-5 Commercial Boilers and Domestic Water Heaters APG-5 Your Number One Source for any domestic hot water or hydronic space heating application RBI offers the most complete line of finned copper tube boilers

More information

G315/5 Cast Iron Boiler

G315/5 Cast Iron Boiler Engineering Submittal Sheet Boiler Overview LISTED Engineering Specifications There shall be provided and installed G315-5 Buderus sectional cast iron hot water boiler(s), suitable for forced draft firing

More information

mith Mills Smith Mills 6500A 6500A-4 OIL OR GAS CAST IRON BOILER/BURNER CAST IRON

mith Mills Smith Mills 6500A 6500A-4 OIL OR GAS CAST IRON BOILER/BURNER CAST IRON mith Mills Mills 00A OIL OR GAS CAST IRON BOILER/BURNER Smith CAST IRON 00A- - Gas I=B=R Ratings: Gross Output 7,19 to 1, FRONT VIEW WITH INDUS COMB BURNER SIDE VIEW WITH INDUS COMB BURNER SIDE VIEW -

More information

G515/7 Cast Iron Boiler

G515/7 Cast Iron Boiler Engineering Submittal Sheet Boiler Overview Engineering Specifications There shall be provided and installed G515-7 Buderus sectional cast iron hot water boiler(s), suitable for forced draft firing with

More information

Raptor 320HB & 399HB Submittal Sheet

Raptor 320HB & 399HB Submittal Sheet Raptor 320HB & 399HB Submittal Sheet Light Commercial High Efficiency Gas s RPTR320HB & RPTR399HB RPTR Wall Mount and Floor Standing Heating s Wholesaler Job Name Mechanical Contractor Number Gas Type

More information

RBI MASTERSPEC. A. This Section includes gas-fired, non-condensing finned copper water tube water heaters for heating hot water.

RBI MASTERSPEC. A. This Section includes gas-fired, non-condensing finned copper water tube water heaters for heating hot water. MSWFTIII-7 SECTION 22 34 36.29 - SAMPLE SPECIFICATION FOR RBI FUTERA III MODULATING WATER HEATER PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General

More information

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER PART 1 GENERAL 1.01 RELATED DOCUMENTS A. ANSI Z21.13 American National Standard for Gas-Fired Low Pressure Steam and Hot Water Boilers B. ASME Section

More information

Suggested Specifications Prestige Excellence 110

Suggested Specifications Prestige Excellence 110 Suggested Specifications Prestige Excellence 110 General Requirements A. Furnish and install (qty) completely assembled, modulating, sealed combustion, high efficiency, combination gas-fired boiler(s)

More information

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS XPAK FT TYPE H - MODELS 088AR-398A SUGGESTED SPECIFICATIONS Catalog No.: 2100.91 Effective: 05/01/15 Replaces: new DIVISION 23 52 33.13 WALL-HUNG STAINLESS STEEL HEATING BOILERS PART 1 - GENERAL 1.1 SUMMARY

More information

GB Condensing Gas Boiler

GB Condensing Gas Boiler Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus GB142/45 wall-hung condensing hot water boiler(s), suitable for induced

More information

G615/11 Cast Iron Boiler

G615/11 Cast Iron Boiler Engineering Submittal Sheet Boiler Overview LISTED Engineering Specifications There shall be provided and installed G615-11 Buderus sectional cast iron hot water boiler(s), suitable for forced draft firing

More information

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT MODBUS AND BACnet MSTP PROTOCOL CASCADING SEQUENCER WITH CASCADE REDUNDANCY 6 INPUTS FROM 750,000 TO 2.0 MILLION BTU/HR UP TO 25:1 TURNDOWN RATIO

More information

FLEXCORE SERIES MASTERSPEC

FLEXCORE SERIES MASTERSPEC FLEXCORE SERIES MASTERSPEC MSFC-2 SECTION 23 52 16 - CONDENSING HIGH EFFICIENCY STAINLESS STEEL FIRETUBE BOILERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract,

More information

JE Series Cast Iron Commercial Natural Gas Steam Boiler Submittal/Specifications

JE Series Cast Iron Commercial Natural Gas Steam Boiler Submittal/Specifications JE Series Cast Iron Commercial Natural Gas Steam Boiler Submittal/Specifications Engineer: Project Name: Project Location: Contractor: PPLICTION: Modular Gas Fired Steam heating boiler for indoor installations.

More information

WHAT TO DO IF YOU SMELL GAS

WHAT TO DO IF YOU SMELL GAS AHE AHE SERIES 4 Direct Vent Wall-Mounted Boilers User s Information Manual If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, personal

More information

83.5 % UP TO 95 % 86.5 % High to Mid-Efficiency Residential & Commercial Heating Solutions. Boilers and Indirect Water Heaters

83.5 % UP TO 95 % 86.5 % High to Mid-Efficiency Residential & Commercial Heating Solutions. Boilers and Indirect Water Heaters High to Mid-Efficiency Residential & Commercial Heating Solutions Innovative. Efficient. Dependable. Dunkirk. Boilers and Indirect Water Heaters Helix VLT Series Gas-Fired Condensing Boiler UP TO 95 %

More information

H 2 HYDRONIC BUFFER TANKS INSTALLATION, OPERATION & MAINTENANCE MANUAL

H 2 HYDRONIC BUFFER TANKS INSTALLATION, OPERATION & MAINTENANCE MANUAL O HYDRONIC BUFFER TANKS INSTALLATION, OPERATION & MAINTENANCE MANUAL 22, 40, 60, 80, 115 Gallon 2 = 2 inch NPT Pipe Connections 112 = 1½ inch NPT Pipe Connections 114 = 1¼ inch NPT Pipe Connections WC

More information

CSD-1 COMMERCIAL BOILER CONTROLS

CSD-1 COMMERCIAL BOILER CONTROLS SUPPLEMENTAL INSTALLATION AND OPERATING INSTRUCTIONS CSD- COMMERCIAL BOILER CONTROLS P/N 400043, Rev. A [/03] CSD- COMMERCIAL BOILER CONTROLS! WARNING Fire, explosion, asphyxiation and electrical shock

More information

H 2. Hydronic Buffer Tanks INSTALLATION, OPERATION & MAINTENANCE MANUAL MODELS

H 2. Hydronic Buffer Tanks INSTALLATION, OPERATION & MAINTENANCE MANUAL MODELS MODELS OBT402 OBT40112 OBT40114 OBT402WC OBT40112WC OBT40114WC OBT602 OBT60112 OBT60114 OBT602WC OBT60112WC OBT60114WC OBT802 OBT80112 OBT80114 OBT802WC OBT80112WC OBT80114WC OBT1152 OBT115112 0BT115114

More information

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage R ISO 9001 COMMERCIAL DOMESTIC HOT WATER GENERATOR Gas, Oil or Combination Gas/Oil 199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage NOW AVAILABLE WITH... NO TANK LINING REQUIRED NO ANODES REQUIRED

More information

Series EC/ECT Residential - Packaged or Knockdown Natural Draft Venting Flame Retention Burner Steam or Hot Water Boilers Optional Tankless Coils

Series EC/ECT Residential - Packaged or Knockdown Natural Draft Venting Flame Retention Burner Steam or Hot Water Boilers Optional Tankless Coils OIL-FIRED Series Residential - Packaged or Knockdown Natural Draft Venting Flame Retention Burner Steam or Hot Water s Optional Tankless Coils Standard Equipment: Cast Iron Sections - Factory Tested and

More information

Standard Equipment: Water. 30 PSI Safety Relief Valve Temperature-Pressure Gage BOILER RATINGS. Series WBV. Steam, MBH 3

Standard Equipment: Water. 30 PSI Safety Relief Valve Temperature-Pressure Gage BOILER RATINGS. Series WBV. Steam, MBH 3 OIL-FIRED Residential - Packaged or Knockdown Natural Draft Venting Flame Retention Burner Steam or Hot Water s Optional Tankless Coils Rear or Top Flue Convertibility Standard Equipment: Cast Iron - Factory

More information

Series 8H. Cast Iron Gas Fired Commercial Water Boiler

Series 8H. Cast Iron Gas Fired Commercial Water Boiler Series 8H Cast Iron Gas Fired Commercial Water Boiler to 0 MBH Input Over 8% Efficient 0 or 0 PSI Cast Iron Sectional Design Atmospheric Vent Modular/Multiple Boiler Configurations Available Series 8H

More information

DIVISION FIRE-TUBE STAINLESS STEEL HEATING BOILERS

DIVISION FIRE-TUBE STAINLESS STEEL HEATING BOILERS XVERS TYPE H - MODELS 0856-3006 SUGGESTED SPECIFICATIONS Catalog No.: 2000.84A Effective: 06/22/18 Replaces: 3/15/18 DIVISION 23 52 33.13 FIRE-TUBE STAINLESS STEEL HEATING BOILERS - GENERAL 1.1 SUMMARY

More information

Multiple Boilers Electro TS Series Application EB-C-STG5

Multiple Boilers Electro TS Series Application EB-C-STG5 Multiple Boilers Electro TS Series Application EB-C-STG5 Drawings: BC025 BX404 BH504 XX017 Information All Electro-Boilers, except Mini-Boiler, have the same control board (EB5623**). The plug-in control

More information

GB Condensing Gas Boiler

GB Condensing Gas Boiler Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus GB12/90 condensing hot water boiler(s), suitable for induced draft

More information

Is a heating protection plan really worth it? Decide for yourself!

Is a heating protection plan really worth it? Decide for yourself! Is a heating protection plan really worth it? Decide for yourself! Priority Customer Service Our customers are important to us. We make you a priority by putting you at the top of the list. Add Years to

More information

RBI MASTERSPEC. A. This Section includes gas-fired, non-condensing finned copper water tube boilers for heating hot water.

RBI MASTERSPEC. A. This Section includes gas-fired, non-condensing finned copper water tube boilers for heating hot water. MSFTIII-9 SECTION 23 52 33.19 - SAMPLE SPECIFICATION FOR RBI FUTERA III MODULATING BOILER PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and

More information

Bosch Buderus SSB1000TL/TL2/TL3/TL4 Stainless Steel Condensing Boiler

Bosch Buderus SSB1000TL/TL2/TL3/TL4 Stainless Steel Condensing Boiler Bosch Buderus SSB1000TL/TL2/TL3/TL4 Engineering Submittal Sheet Boiler Components C US Engineering Specifications There shall be provided and installed Bosch Buderus Model SSB1000TL in quantities of. Bosch

More information

FINNED WATER-TUBE POOL HEATERS

FINNED WATER-TUBE POOL HEATERS HI DELTA, TYPE P - MODELS 502C-902C SUGGESTED SPECIFICATIONS Catalog No.: 6000.601A Effective: 07-12-18 Replaces: 10-31-16 FINNED WATER-TUBE POOL HEATERS - GENERAL 1.1 SUMMARY A. Section includes gas-fired,

More information

ClearFire - Hydronic Startup Report

ClearFire - Hydronic Startup Report ClearFire - Hydronic Startup Report Date Serial No. THIS FORM IS FOR MODEL CFC / CFW CLEARFIRE BOILERS Customer s Name Location Model Design Pressure Working Pressure Rated Input (nameplate rating) BTU/hr

More information

mith Mills 4500A Smith Mills 4500A 4500A-3R OIL, GAS OR COMBINATION GAS/OIL COMMERCIAL BOILER/BURNER CAST IRON

mith Mills 4500A Smith Mills 4500A 4500A-3R OIL, GAS OR COMBINATION GAS/OIL COMMERCIAL BOILER/BURNER CAST IRON Mills 00A mith Mills 00A Smith CAST IRON OIL, GAS OR COMBITION GAS/OIL COMMERCIAL BOILER/BURNER 00AR STEAM GAUGE OPERATING CONTROL MODULATING CONTROL HI LIMIT PRESSURE CONTROL 0" STEAM DRUM TEST COCK /"

More information

Boiler & Water Heater

Boiler & Water Heater MIGHTY THERM2 Date: Project #: Pump-Mounted Boiler & Water Heater MT2H Hydronic Heater MT2V Volume Water Heater Indoor/Outdoor Sizes 500-2000 Submittal Engineer: Project Name: Prepared By: Location: Bid

More information

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY SENTRY High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY SENTRY High efficiency, cast-iron gas boiler A smarter choice for informed The boiler you choose for your home

More information

Replacement parts EG/PEG

Replacement parts EG/PEG Replacement parts EG/PEG Table 13 EG/PEG replacement parts A B Left hand end section with heater opening (Pattern No. 1814) Left end section without heater opening(pattern No. 1813) Right hand end section

More information

INSTALLATION AND OPERATION INSTRUCTIONS

INSTALLATION AND OPERATION INSTRUCTIONS Printed in U.S.A. INSTALLATION AND OPERATION INSTRUCTIONS RFPA21A CONSTRUCTION HEATER FLOOR MODEL SAVE FOR FUTURE REFERENCE Space-Ray Division, Gas Fired Products, Inc. P.O. Box 36485, Charlotte, NC 28236

More information

Trade Price Book - 816

Trade Price Book - 816 Trade Price Book - 816 Innovative. Efficient. Dependable. Dunkirk. Helix VLT Available in 50 to 299 MBH Built in Primary/Secondary Piping 95 Helix VX Available in 50 to 200 MBH 95 Q90-100 Series IV Cast

More information

Storage Tanks. Instruction Manual. To the Installer: Please attach these instructions next to the water heater.

Storage Tanks. Instruction Manual. To the Installer: Please attach these instructions next to the water heater. To the Installer: Please attach these instructions next to the water heater. To the Consumer: Please read these and all component instructions and keep for future reference. Storage Tanks Instruction Manual

More information

WATER-TUBE POOL HEATERS

WATER-TUBE POOL HEATERS XTHERM, TYPE P - MODELS 1005A-2005A SUGGESTED SPECIFICATIONS Catalog No.: 6000.63B Effective: 3-01-15 Replaces: 9-01-09 WATER-TUBE POOL HEATERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes condensing,

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS HI DELTA, TYPE H - MODELS 992C-2342C SUGGESTED SPECIFICATIONS Catalog No.: 2000.953 Effective: 10-31-16 Replaces: NEW DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS - GENERAL 1.1 SUMMARY A. Section includes

More information

WATER-TUBE POOL HEATERS

WATER-TUBE POOL HEATERS XTHERM, TYPE P - MODELS 2505-4005 SUGGESTED SPECIFICATIONS Catalog No.: 6000.70 Effective: 09-15-16 Replaces: NEW WATER-TUBE POOL HEATERS - GENERAL 1.1 SUMMARY A. Section includes condensing, gas-fired

More information

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired Form No. 8700 Bryan Flexible Water Tube TM Triple-Flex Series Ultra-High Efficiency Condensing Hot Water Boilers 3,000,000 BTUH Natural Gas Fired Minimum 90% Thermal Efficiency at 160 F Return with 20

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FOR AQUECOIL HYDRONIC HEATING UNITS GENERAL INFORMATION The AQUECOIL Hydronic Heating Unit is offered in many different capacities and physical configurations in order to match

More information

Automatic Circulating Water Heaters

Automatic Circulating Water Heaters XP CIRCULATING WATER HEATER The ENERGY STAR Qualified A. O. Smith high efficiency condensing XP Water Heater utilizes a state-of-the-art heat exchanger and control technology to provide large volumes of

More information

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS KG6RC Series High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/ Horizontal Gas Furnace Induced Draft - 92+ AFUE Input 40,000-120,000 Btuh The high effi ciency

More information

Bosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler

Bosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler Bosch Buderus SSB800/1000/1000TL Engineering Submittal Sheet Boiler Components C US Engineering Specifications There shall be provided and installed Bosch Buderus Model SSB800 SA, Model SSB1000 SA, Model

More information

VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler

VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler VICTORYVSPH VICTORY VSPH Cast-iron sealed combustion, direct vent gas boiler Cast-iron sealed combustion, direct vent gas boiler THE PERFECT CHOICE FOR NEW RESIDENTIAL CONSTRUCTION, RELIABILITY AND ECONOMY.

More information

HHA Lyerly Apartments 75 Lyerly Houston, Texas J. Allen Management Managing Agent

HHA Lyerly Apartments 75 Lyerly Houston, Texas J. Allen Management Managing Agent HHA Lyerly Apartments 75 Lyerly Houston, Texas 77022 J. Allen Management Managing Agent Scope of Work: 1.) Boiler Replacement with Double Vertical Boiler System (1 Million btu each) 2.) Water Pump Replacement

More information

Features & Benefits. Description. Example of LCD display screen. Functionality. Ordering Information: Model 7600 Boiler Control

Features & Benefits. Description. Example of LCD display screen. Functionality. Ordering Information: Model 7600 Boiler Control Model 7600 Boiler Control PARTS & ACCESSORIES Features & Benefits Beckett HeatManager TM dynamic temperature reset Cycle history diagnostic information Reduce inventory through universal design Backlit

More information

High efficiency, cast-iron gas boiler

High efficiency, cast-iron gas boiler SENTRY High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY SENTRY High efficiency, cast-iron gas boiler A smarter choice for informed The boiler you choose for your home

More information

INDOOR/OUTDOOR, HOT WATER HEATERS AND HYDRONIC HEATING BOILERS

INDOOR/OUTDOOR, HOT WATER HEATERS AND HYDRONIC HEATING BOILERS LCD-5 INDOOR/OUTDOOR, HOT WATER HEATERS AND HYDRONIC HEATING BOILERS The LCD Dominator Series from RBI offers competitively-priced indoor/outdoor units that meet low NOx requirements, while maintaining

More information

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS Replacement parts Figure 92 Propane conversion kits and instructions Boiler model DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE The WM97+ maintenance kit includes components that

More information

STERLING RSG SERIES INFRARED RADIANT TUBE HEATER

STERLING RSG SERIES INFRARED RADIANT TUBE HEATER RSGS-1 RSG SERIES TUBE HEATERS RSG 25 RSG 35 RSG 45 (Check One) NATURAL GAS (Check One) PROPANE GAS EQUIPMENT USED: ACCESSORIES: Chain Mounting Kit: Thermostat: Gas Pressure Regulator: Gas Shut-Off Valve:

More information