the security screw.) Insert cable in the central hole of the base. Align the base and mark the location of the two mounting holes on the wall.
|
|
- Sybil Lambert
- 5 years ago
- Views:
Transcription
1 H200 Bard Part Number Viconics Model H O. 1 OR 2 OUTPUTS. OUTPUT #2 CAN BE A HUMDTY LEVEL TRANSMTTER ( Not to be used in corrosive or harmful environment) HUMDSTAT WTH:. Remove security screw on left side of humidistat cover.. Open up by pulling on the left side of humidistat. TO OPEN HUMDSTAT COVER 1 [- ~ HUMDSTAT NSTALLATON (ROOM HUMDSTAT) J ~ A) Location: 1- Shouldn>t be installed on outside wall. 2- Must be installed away from any heat source. 3- Shouldn>t be affected by direct sun radiation. 4- Nothing must restrain vertical air circulation to the humidistat. B) nstallation: 1- Pull out cables 6" out of the wall. 2- Wall sulface must be flat and clean. 3- Separate the humidistat and the base by pulling cover on the left side (same as the security screw.) nsert cable in the central hole of the base. Align the base and mark the location of the two mounting holes on the wall. nstall shields in the wall.. nsert screws in mounting holes on each side of the base. DO NOT OVERTGHTEN! 8- Open the cable protection 1 1/4 inch more or less. 9- Strip each wire 1/4 inch. 10- nsert each wire accor:dingto wiring diagram. 11- Reinstall the cover ( right side first ). 12- nstall security screw P:\028-MANUELS\028-2l02.doc 2/21/06 Page: 1
2 HUMDSTAT NSTALLATON (DUCT HUMDSTAT) 1. Make a hole 1" dia. in the duct. 2. Remove the right screw on the thermostat base and slack the left one a couple ofturn. 3. The electrical box must be installed horizontally to install the humidity sensor correctly in the flow. 4. Screw the electrical box on the duct. 5. Pull the wires through a knock out hole in the electrical box and then through the holeof the base.. Reinstall the base and screw it back into place. Connect the wires as per wiring diagram. Reinstall the cover (right side first). nstall security screw. ARFLOW DRECTON -.. o. NSERT WRNG THROUGH ELECTRCAL BOX KNOCK OUT MOUNTNG HOLES SENSOR CONNECTONS All sensors used as main sensor, either inside humidistat or duct mount are connected to these pins on the humidistat base: 6 (black) common, 7 (white), R.H. input 10 (red), 10 Vdc source.. Characteristicsof sensor.(voltagebetweenblack and white) ( Typical at exactly 10 Vde source) HUMDTY SENSOR OUTPUT 0% 1.05 V 5% 1.19 V, 10% 1.34 V 15% 1.48 V 20% 1.63 V 25% 1.77V 30% 1.92 V 35% 2.06 V 40% 2.20 V 45% 2.35V 50% 2.49 V 55% 2.64 V 60% 2.78 V 65% 2.93V 70% 3.07V 75% 3.21 V 80% 3,36V 85% 3.50 V 90% 3.65 V 95% 3.79V 100% 3.94V Page: 2
3 CALBRATON OF THE HUMDSTAT The humidistat comes precalibrated from the factory.. f it needs to be recalibrated in the field, this is done using the AUTOCAL button. To calibrate the humidistat: Read the humidity with a precision hygrometer. Adjust the setpoint to humidity reading. Press the autocal button until the light comes on (look through the slots on the left side of the humidistat. That should take 8 seconds. Release the button. The humidistat is calibrated. See dimensions drawing for the position of the AUTOCAL button ( do not open the cover; you can feel the button by pressing on the cover. ) SENSOR DEFECT The sensor is the most sensitive part of the transmitter, and also the most exposed. n the case of sensor failure, the sensor would normally return a 0% humidity reading. The H200 has an internal failure detection system that will automatically return 120% signal if the sensor is defective. This will assure a fail safe operation in all situations. Please read the specification carefully. Viconics will assume no warranty for misuse of the product. SPECFCATONS Operating Conditions: Control: Sensor: Humidity sensor: Resolution Repeatability: Accuracy of sensor. interchangeability: Range: Temperature effect: Outputs:: Power: 5 C to 50 C ( 32 of to 122 OF) 0% to 95% R.H. non-condensing 0% to 100% R.H. Solid state humidity sensor. Suitable for normal, clean air. Not to be used in corrosive or harmful environment. ::i:o.l % 0.5% :i:2 % R.H. from 0 to 100 % R.H. 10 % to 90 % R.H. for 5 to 50 C (32 of to 122 OF) 0.05 %/OF solated Triac: 30 Vac at V2A max. o 15 Vdc pulsed at 20 ma max. for both outputs. o to 5 Vdc into lkq resistance min. o to 10 Vdc into 2KQ resistance min. 24 VAC -15%, + 10% 50/60 Hz; 2 VA.
4 DMENSONS W1R1NG FROM TOP OR FROM BACK BASE 80 ROOM HUMDSTAT :E " ( 83 mm ) VCONCS so :(D ' ":.... lu ~ 4.5" ( 114mm) HDDEN AurOCAL BUrToN PRESS ON THE LEX.ANCOVER GENT..Y COVER ~1~ ~ 2.8".1 ( 71mD) 11 DUCT HUMDSTAT 1.275" 32mm 2.0" (50.8mm) 2.8" o 3.77" (95.8 mm) 0.9" (n.8am) -L COVER Specifications and equipment are subject to change without prior notice. Page: 4
5 ORDER CODE H200 - GL - [ ] - TD A Output no. 1 ( controlled device) Type 1 Relay, thermal relay, two position motor solated Triac 4 "SSR" with 24 Vac input solated Triac 5 "SSR" with 3-32 Vdc input Pulsed 0/5 Vdc 6 "SCR" or 0-10 Vdc motor Ot010Vdc 8 Output no. 2 ( controlled device) Type o Not installed 1 Relay, thermal relay, two position motor solated Triac 4 "SSR" with 24 Vac input solated Triac 5 "SSR" with 3-32 Vdc input Pulsed 0/5 Vdc 6 "SCR" or 0-10 Vdc motor Ot010Vdc 8 Signal transmitter 1V= 10%,9V-90% Ot010Vdc 9 Signal transmitter O.5V=10 % ; 4.5 V=90 % 0 to 5 Vdc C Output no. 1 and 2 control mode 1 Humidify. -..,...., Standard 2 Dehumidify 3 Humidify ( no. 1 ) and dehumidify ( no. 2) 4 Dehumidify ( no. 1 ) and humidify ( no. 2 ) D Main sensor location Sensor o Not installed None 1 nside humidistat ( Local) H50 2 Duct mount ( stat on duct) H60 3 Duct mount ( stat on wall) H70 4 Remote wall mount H80 * Standard E Setpoint adjustment -- 1 User adjustable 2 Blind cover * Standard Future option Unused. Standam Page: 5
6 Example: H One "SCR" 0 to 10 volts humidify output and one relay dehumidify output. Humidistat and sensor are duct mount. Setpoint is user adjustable. + Field changeable plug-in resistor NOTE: THE COMPLETE ORDER CODE NCLUDES THE SENSOR THAT WLL BE SHPPED WTH THE HUMDSTAT. WRNG H200 WRNG EXAMPLE: OUTPUT #2 o TO 5 Vde o TO 10 Vde 2 TRANS:MT. OUTPUT #1 OT05Vde. o TO 10 Vde 24 Vae 24V AC + DDC SYSTEM, ORSCR., -, OR METER. + ELECTRONC MOTOR.,SCR. MAJN SENSOR NPUT BLACK WHTE RED FOR CONTROL.. i +10 Vde OUTPDTWRNGFOR SOLATEDTRAC OUTPUTS OUTPUT 1 SOLATED TRAC :::;:: * RELAY OR VALVE 24 Vae * NOTE: USE TERMNALS NO.1 AND 2 FOR OUTPUT 2 Bard Part Number Viconics Model H Application Notes: 1. nternal LED is "On" for approximately 8 seconds when controller is powered up, and it comes on during recalibration procedure. t does not come On during normal operation with output either On or Off. 2. Controller takes approximately 8-10 seconds to power up and issue output---if calling. 3. Typical wiring connections: a. Terminal 3 and 4 relay output, NO, closes on rise b. Terminal 5 24V Hot (R) c. Termina6 24V Common (C) Page: 6
ELECTRONIC HUMIDISTAT: H200
ELECTRONIC HUMIDISTAT: H00 ONE OR TWO STAGES DESCRIPTION The H00 series low voltage, microcomputerbased PI (proportional and integral) humidistats are designed for accurate humidification and/or dehumidification
More informationELECTRONIC HUMIDISTAT: H270
ELECTRONIC HUMIDISTAT: H0 ONE OR TWO STAGES HUMIDITY SUPPLY OUTDOOR TEMPERATURE RESET DESCRIPTION The H0 series low voltage, microcomputerbased PI (proportional and integral) humidistats are designed for
More information0-10 V Wall & Duct Humidistat Installation Instructions
0-10 V Wall & Duct Humidistat Installation Instructions This document covers the operation and installation instructions for the following Nortec Digital Humidistats: Part #: Description: 1510142 0-10
More informationCP CP
CP-8161-333 CP-8161-433 Electronic Programmable Controller Six Stage, Dual Setpoint General Instructions APPLICATION Electronic six stage programmable controller with proportional output for heating, cooling
More informationInstructions. Infiniti Gas Transmitter Model U Rev: 4/
nstructions nfiniti Gas Transmitter Model U9500 Rev: 4/12 Table Of Contents APPLCATON.... 1 SETUP PROCEDURE... 20 FEATURES... 1 SPECFCATONS... 1 DESCRPTON... 3 MPORTANT SAFETY NOTES.... 4 NSTALLATON...
More informationRH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description
RH & T Sensors & Humidistats RH-DT Duct Mount RH & T Sensors Description RH-DT Duct Mount RH & T Sensors The RH-DT Duct Mounted Humidity and Temperature Sensors offer the latest technology for high accuracy
More informationW43A Humidistat. Features and Benefits
Master Catalog 125 Humidity Controls Section W Product/Technical Bulletin W43A Issue Date 1095 W43A The W43A controls humidifying and/or dehumidifying equipment. Typical uses include the control of humidity
More informationFan Coil Thermostat Controller Specification and Installation Instructions. Model TFH24F3XYZ2 Stand-alone with Internal Humidity Sensor
Model TFH24FXYZ2 Stand-alone with Internal Humidity Sensor Description The TFH24FXYZ2 is a fully configurable controller designed specifically for 2 pipe and 4 pipe fan coil applications. No additional
More informationTCI-W-U Series Wall Mounted Controller Installation and Operation Manual IOM-525
TCI-W-U Series Wall Mounted Controller Installation and Operation Manual IOM-525 Installation and Set Up Overview Features...3 Duct Application...4 Room Application...5 Wiring Schematics...6-12 Operation...13-14
More informationWarranty Registration
WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product and the component parts thereof will be free from defects in workmanship and materials for a period of
More informationSchneider Electric Erie T155 Series
Schneider Electric Erie T Series Non-Digital, On/Off Thermostat General Instructions Application The T series thermostat provides on/off control for low voltage and line voltage valves, relays and fan
More informationT6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats XE88/XE100 SERIES
T7A, T7A,B, TA,B, TB Digital Fan-Coil Thermostats XE/XE00 SERES FEATURES PRODUCT DATA Attractive modern styling with digital display makes the thermostat ideal for offices or hotels. Hotel card key input
More informationSafety, Installation, and Operation Manual
Automatic Steam Humidifier Control Safety, Installation, and Operation Manual READ COMPLETE INSTALLATION INSTRUCTIONS BEFORE STARTING. WARNING This product must be installed by a qualified heating and
More informationINSTALLATION INSTRUCTIONS MASTER CONTROLLERS MC91AE MC92AE MC93AE MC94AE MC94AEH MC96AEH
INSTALLATION INSTRUCTIONS MASTER CONTROLLERS MODELS: MC91AE MC92AE MC93AE MC94AE MC94AEH MC96AEH Bard Manufacturing Company Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. Manual: 2100-189I
More informationHTO-45 HUMIDITY TEMPERATURE PROBE INSTRUCTION MANUAL
HTO-45 HUMIDITY TEMPERATURE PROBE INSTRUCTION MANUAL -2- CONTENTS DESCRIPTION...3 OPERATION...3 INSTALLATION (Tips for fixed probe installation)...4 MAINTENANCE...6 CALIBRATION...6 SPECIFICATIONS...8 PLEASE,
More informationQ-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air
Document No. 155-755 Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air Description Features Application The Q-Series Relative Humidity and
More informationINSTALLATION INSTRUCTIONS MASTER CONTROLLERS MC91AE MC92AE MC93AE MC94AE MC94AEH MC96AEH MC97AE-1
INSTALLATION INSTRUCTIONS MASTER CONTROLLERS MODELS: MC91AE MC92AE MC93AE MC94AE MC94AEH MC96AEH MC97AE-1 Bard Manufacturing Company Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. Manual:
More informationFan Coil Thermostat Controller Specification and Installation Instructions. Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication
Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication Description The TFHB24F3XYZ1 is a fully configurable controller designed specifically for 2 pipe and 4 pipe fan coil applications.
More informationInstallation Instructions
Fixture Mount Night Light Controller SPECIFICATIONS Power.....................................120VAC, 60Hz Relay Type..................................Form C, N.O. Load Requirements @120VAC......................................500W..........................
More informationPackage Electric Heater Kits
HHK Series Package Electric Heater Kits Description nstallation of 0/40V and 460V HHK Heater Kits in Packaged Air Conditioners and Packaged Heat Pumps. These instructions are primarily intended to assist
More informationVH7200 Humidistat Series For Humidification & Dehumidification Control For Commercial HVAC Applications (Issue Date January 22, R7)
VH7200 Humidistat Series For Humidification & Dehumidification Control For Commercial HVAC Applications (Issue Date January 22, 2013 028-0208 R7) 1 Product overview The VH7200 humidity controller family
More informationSystem 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules
System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage s FANs 930, 125 Product/Technical Bulletin S350 Issue Date 0300 The S350A, S351A, and S352A Stage s are intended to be used with System
More informationAutomatic Humidity Controller. Model 512 (Revision C) Operating Manual
Automatic Humidity Controller Model 512 (Revision C) Operating Manual 6/5/03 1 TABLE OF CONTENTS 1.0 INTRODUCTION 3 2.0 GENERAL DESCRIPTION 3 3 2.1 Humidity Sensor 3 2.2 Control Unit 4 2.3 System Operation
More information± 3% or better at 40%RH and 23ºC [73ºF] 0.8 mm 2 [18 AWG] minimum
Room Humidistat Features: Attractive modern look with large LD and backlight Icons driven information and 1 line of text External humidity sensor input Humidification and dehumidification indicator Multi
More informationOperations Manual. Motion Detector Module Model ZS10
Motion Detector Module Model ZS10 The must be referred to for correct installation. Failure to comply with the shall void all warranties and liabilities. Overview The ZS10 Motion Detector Module is an
More informationModel OEM-2 INSTRUCTIONS FOR USE
ECO SENSORS, INC. 3-03.2 OEM OZONE CONTROLLER Model OEM-2 INSTRUCTIONS FOR USE GENERAL The model OEM-2 is a system to control ozone generators and alarms based on an adjustable ozone concentration set
More information23 October Enervent Neo. Ventilation unit installation instructions
23 October 2017 Enervent Neo Ventilation unit installation instructions Copyright Enervent 2017. Unauthorised copying and distribution is forbidden. 2 CONTENTS READ FRST...4 Type plate...5 SAFETY...6 General...6
More informationINSTRUCTIONS REHAU SILENT DIAL THERMOSTAT #
INSTRUCTIONS REHAU SILENT DIAL THERMOSTAT #236477-001 Specifications... 1 Overview Silent Dial Thermostat Art. 236477-001... 1 Mounting Location... 3 DIP Switch Configuration... 3 Calibration... 5 Setting
More informationTemperature & Humidity Controllers
Electromechanical Temperature Controls T631 Air witch Controller Air witch Controller with heavy-duty corrosion resistant steel case. uitable for lift motor rooms, farm storage areas etc. Line voltage
More informationIDP-Zone-6 Six Zone Interface Module
INSTALLATION AND MAINTENANCE INSTRUCTIONS IDP-Zone-6 Six Zone Interface Module BEFORE INSTALLING If the modules will be installed in an existing operational system, inform the operator and local authority
More informationHumidity Controller Specification and Installation Instructions. Model HRO20
Model Description The Humidity Controller is an advanced application to control relative humidity for general purpose applications. They are specially designed to control humidifiers and dehumidification
More informationHumidifiers. Drum Type. Flow Through Type C31 12/07/13
12/07/13 Drum Type C31 Humidifiers Installs on vertical warm air supply or cold air return plenum All models include humidistat and installation package (transformer, solenoid valve, saddle valve & evaporator
More informationWiring Instructions. High-Capacity Steam Humidifiers
Wiring Instructions for High-Capacity Steam Humidifiers Including Instructions for Compensating Humidistat and Safety Control Shutoff CONTRACTOR: Read these instructions before installing or servicing
More informationHygro/hygrothermal transducers (hygrometric)
Data Sheet 907031 Page 1/7 Hygro/hygrothermal transducers (hygrometric) for measuring relative humidity and temperature for mounting indoors, outdoors, and in air ducts with resistance, current or voltage
More informationResistance heaters. Ventilation systems. Air-air exchangers. Air-water exchangers. Cooling units. Control devices. Calculation and selection
7 0 Selection guide TO CONTROL THE TEMPERATURE Respects the entered value Compact fixed thermostats Preset factory temperature: NA (blue button):, 0, ºC for the resistance heater. (red button):, 0, ºC
More informationELECTRIC AIR HEATER INSTALLATION AND SERVICE MANUAL
ELECTRIC AIR HEATER INSTALLATION AND SERVICE MANUAL BC(E) SERIES INDOOR / OUTDOOR MANUFACTURED BY GENERAL INFORMATION PROJECT: ADDRESS: MODEL: SERIAL NUMBER: INSTALLER: ADDRESS: TELEPHONE: INSTALLATION
More informationInstruction Manual Model A
706 Bostwick Avenue, Bridgeport, CT 06605 TEL: 203-368-6751 FAX: 203-368-3747 1-800-566-6822 www.devarinc.com Instruction Manual Model 18-232A LOOP POWERED ALARM MANUAL NO. 990029 MODEL 18-232A LOOP POWERED
More informationCATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION
CATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION PRODUCTS INDEX EXPERT NANO 1LT 06 PLUS200 EXPERT THR 34 EXPERT NANO 3CF 08 PLUS300 EXPERT U THR 36 EXPERT NANO 4CK 10 PLUS1000 THR 38 EXPERT NANO 2ZN
More informationT6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats
TA, TA,B, TA,B, TB Digital Fan-Coil Thermostats XE/XE00 SERES FEATURES PRODUCT DATA Attractive modern styling with digital display makes the thermostat ideal for offices or hotels. Hotel card key input
More informationDuct and Rough Service Carbon Monoxide Sensor
Product Identification and Overview Duct and Rough Service Carbon Monoxide Sensor BAPI s Carbon Monoxide Sensor offers enhanced electrochemical sensing with outstanding accuracy at low concentrations.
More informationT7984 A,B,C Electronic Modulating Control Thermostats
T7984 A,B,C Electronic Modulating Control Thermostats FEATURES PRODUCT DATA APPLICATION These microprocessor-based thermostats provide proportional - integral (PI) individual room temperature control in
More informationTEC1100 Series Thermostats
Metasys Network Sales Resource Manual 635 Application Specific Controllers Section Product Bulletin Issue Date 0601 TEC1100 Series Thermostats TEC1100 is a series of non-programmable thermostats with a
More informationMICROFAN B.V. Industriestraat PH Horst P.O. Box AA Horst Developing, manufacturing and marketing of MICROFAN
Manual MIST TIME Version MIS 1.4-LP December 18, 2006 MICROFAN B.V. Industriestraat 23 5961 PH Horst P.O. Box 6022 5960 AA Horst Developing, manufacturing and marketing of MICROFAN The Netherlands computers,
More informationMP 601A Humidity Probe INSTRUCTION MANUAL
MP 601A Humidity Probe INSTRUCTION MANUAL CONTENTS DESCRIPTION... 3 OPERATION... 3 WIRING... 5 INSTALLATION... 7 MAINTENANCE...7 CALIBRATION BASICS... 8 CALIBRATION PROCEDURE... 9 SPECIFICATIONS... 11
More informationModus Model DA General Eastern Low Differential Pressure Alarm Controller
GE Sensing & Inspection Technologies Modus Model DA General Eastern Low Differential Alarm Controller The Modus Model DA is a controller designed for the monitoring of low differential pressures. It combines
More informationT8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase
M3375 M3375 T890A/908AJ Heating or Cooling Thermostat/Wallplate; T890A/Q68B Heating/Cooling Thermostat/Subbase Installation Instructions for the Trained Service Technician. Preparation NOTE: Order Q68B
More informationINSTALLATION INSTRUCTIONS FOR MODEL 7330D3351 & 7330D3361 WALL THERMOSTAT
INSTALLATION INSTRUCTIONS FOR MODEL 7330D3351 & 7330D3361 WALL THERMOSTAT APPLICATION These thermostats are designed to operate all R.V. Products ceiling assemblies, which control the air conditioner 115
More informationHAI Omni-Bus Network Installation. 5. Typical Application
HAI Omni-Bus Network Installation 5. Typical Application HAI Omni-Bus Network Installation Notes 1. Network cable 2. Crimp Connectors 3. Network Termination Plug 4. Jumpers 5. Splitters 6. Power Supply
More informationT6984F,G Electronic Floating Control Thermostats
T6984F,G Electronic Floating Control Thermostats FEATURES PRODUCT DATA P+I control action provides accurate, stable room temperature control. Used with ML644 Series 60 Direct Coupled Damper Actuators.
More informationSpecifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE:
The RO120 is a precision transmitter that provides quick and accurate humidity, barometric pressure, temperature, absolute pressure and dew point measurements in a wide range of applications. It has a
More informationHP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS
HP727S Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS 1. General Description 2. Specifications 3. Installation Instructions 4. Electrical Wiring 5. Instrument Wiring
More informationActive Infrared Multi Beam Sensors
Active Infrared Multi Beam Sensors D Series TECHNICAL MANUAL INDEX GENERAL SAFETY RECOMMENDATIONS 3 CONFORMITY 4 WARRANTY 4 INTRODUCTION 5 FEATURES 5 OPERATIONAL RANGE 6 SETUP TRANSMITTER (TX) 6 SETUP
More informationREAD AND SAVE THESE INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS MICROPROCESSOR HUMIDIFIER CONTROL SYSTEM INSTALLATION INSTRUCTIONS and OPERATIONS MANUAL TABLE OF CONTENTS TO THE PURCHASER AND THE INSTALLER: Thank you for deciding to
More informationAnalog Room Pressure Monitor RPC Series
Description The Room Pressure Monitor is used to measure differential pressure in the range of 0.125 to 1"wc or 30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the
More informationPower and Control Module. Plenum Pressurization - PP1 MANUAL INSTALLATION + SERVICE
MANUAL NSTALLATON + SERVCE Power and Control Module Plenum Pressurization - PP1 v000 ssue Date: 01/30/19 2019 Price ndustries Limited. All rights reserved. TABLE OF CONTENTS Product Overview Plenum Pressure
More informationActive Infrared Multi Beam Sensors. R Series
Active Infrared Multi Beam Sensors R Series TECHNICAL MANUAL INDEX GENERAL SAFETY RECOMMENDATIONS 3 CONFORMITY 4 WARRANTY 4 INTRODUCTION 5 FEATURES 5 OPERATIONAL RANGE 6 SETUP TRANSMITTER (TX) 6 SETUP
More informationHygro/hygrothermal transducers (hygrometric)
Data Sheet 90.7031 Page 1/7 Hygro/hygrothermal transducers (hygrometric) for measuring relative humidity and temperature for mounting indoors, outdoors, and in air ducts with resistance, current or voltage
More informationINSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS
INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS For the UH-301 and UH-303 Ultrasonic Humidifiers HUMIDITY SOURCE LLC 30 Garden Ct. S.Garfield, NJ 07026 USA humiditysource@aol.com Phone: 973-916-1001
More informationTemperature Controllers
Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65
More informationDSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE
DSGH Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE Revision History Revision History Version of manual Description Date 1.0 Initial release 051025 1.1
More informationRev Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual
026-1501 Rev 5 3-20-03 Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual 1640 Airport Road, Suite 104 Kennesaw, GA 31044 Phone: (770) 425-2724 Fax: (770) 425-9319 ALL RIGHTS
More informationModel 20201/20201-A/20201-B Wind Sensor Heater. User's Manual. All Weather Inc National Drive Sacramento, CA USA
Model 20201/20201-A/20201-B Wind Sensor Heater User's Manual All Weather Inc. 1165 National Drive Sacramento, CA 95834 USA www.allweatherinc.com 20201 Wind Sensor Heater User's Manual CONTENTS INTRODUCTION...1
More informationGas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:
Gas Safety Products 4500PPM Installation, operating and maintenance Read these instructions carefully before operating or servicing Rev: 11 Date: 09-07-18 1 * The unit should be installed by a competent
More informationOhm Metrics. Instruction Manual. Model CM400 Series. Continuous Workstation Monitors
T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L Ohm Metrics Continuous Workstation Monitors TRANSFORMING TECHNOLOGIES,
More informationINSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents.
INSTALLATION MANUAL This manual covers TopTech models: TT-S-755H Thermostat Applications Guide Description Gas or Oil Heat Electric Furnace Heat Pump (No Aux. or Emergency Heat) Heat Pump (with Aux. or
More informationPOCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS
POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS products index 2 expert nano 06 plus200 EXPERT DATALOGGER 24 ecp_ base4 u vd 40 PEV pulse 60 expert nano 200 NANO 1CF 08 Plus300 EXPERT
More informationINSTRUCTION MANUAL. PUREPRO DP732T 3 Heating and 2 Cooling with Automatic Humidity Control and Dual Fuel Switch 3-YEAR WARRANTY
3-YEAR WARRANTY INSTRUCTION MANUAL PUREPRO DP732T 3 Heating and 2 Cooling with Automatic Humidity Control and Dual Fuel Switch LUX Products Corporation 6000 Commerce Parkway, Suite-I Mt. Laurel, NJ 08054
More informationRC-2000 Thermostat Installation Instructions
RC-2000 Thermostat Installation Instructions DESCRIPTION The RC-2000 is a precision digital thermostat designed for 24 VAC heating and cooling systems. The RC-2000 will support the following systems: Single
More informationHoneywell HumidIcon Digital Humidity/Temperature Sensors. HIH6100 Series ±4.0 %RH Accuracy. Datasheet
Honeywell HumidIcon Digital Humidity/Temperature Sensors HIH600 Series ±4.0 %RH Accuracy Datasheet Honeywell HumidIcon Digital Humidity/Temperature Sensors Honeywell HumidIcon Digital Humidity/Temperature
More informationInstallation Guide IM 1248
Installation Guide IM 1248 BACnet Thermostat for Heat Pump Units Group: Controls Part Number: IM 1248 Date: August 2015 Table of Contents Installation Guide Heat Pump.... 2 Applicable Models... 2 Mounting
More informationGS-1. Instruction Manual. G-Series Cooler. Manual is for the following model: GS-1 GS-1-013EB GS-1-N13EB COUNTERTOP COOLER
G-Series Cooler COUNTERTOP COOLER anual is for the following model: -013EB -N13EB nstruction anual anual is for the following model: -013EB -N13EB nstruction anual FOR YOUR FUTURE REFERENCE This easy-to-use
More informationREAD AND SAVE THESE INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS MICROPROCESSOR HUMIDIFIER CONTROL SYSTEM INSTALLATION INSTRUCTIONS and OPERATIONS MANUAL TABLE OF CONTENTS TO THE PURCHASER AND THE INSTALLER: Thank you for deciding to
More informationANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL
ANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL SAFETY WARNING Please Refer to the Safety Warning in Section 7.1 regarding the chemicals in the oxygen sensor Analox Sensor Technology
More informationNetworkable Fan Coil Controller Specification and Installation Instructions
Controller Models EFCB10T-OE1 (24Vac / 0 relays) EFCB12T-OE1 (240Vac / 0 relays) EFCB10TU4-OE1 (24Vac / 4 relays) EFCB12TU2-OE1 (240Vac / 2 relays) EFCB12TU4-OE1 (240Vac / 4 relays) TFL Series Thermostat
More informationCZ-6A Six Zone Interface Module
INSTALLATION AND MAINTENANCE INSTRUCTIONS CZ-6A Six Zone Interface Module 658 Kitimat Rd. Unit #6 Mississauga, Ontario L5N T5-800-SENSOR, FAX: 905-8-077 www.systemsensor.ca SPECIFICATIONS Normal Operating
More informationModel Smart Digital Humidistat
Model 072000 Smart Digital Humidistat Installation and Owner's Manual TB 213 P/N 090375A0213 REV. E December 5, 2006 Copyright 2004-2006, EWC Controls Inc., All Rights Reserved RH OD %RH TEMP Package includes:
More informationSC Installation, Operation & Application Guide
SC 1800 Manual Changeover Non-Programmable Hardwired Non-Programmable Electronic Thermostat Controls Single Stage Heating Systems Millivolt and Hydronic (water or steam) System Compatible Compatible with
More informationSC-6 Six Supervised Control Module
INSTALLATION AND MAINTENANCE INSTRUCTIONS SC-6 Six Supervised Control Module SPECIFICATIONS Normal Operating Voltage: Stand-By Current: Alarm Current: Temperature Range: Humidity: Dimensions: Accessories:
More informationTRUERH Series HE-67xx Humidity Element with Temperature Sensor
Installation Instructions HE-67xx Issue Date 0501 TRUERH Series HE-67xx Humidity Element with Temperature Sensor Installation IMPORTANT: The HE-67xx Series Humidity Element with Temperature Sensor is designed
More informationINSTALLATION & USER MANUAL
INSTALLATION & USER MANUAL HC Digital Automatic Humidistat (Y3760) CONTROLS 506808-01 3/2016 Supersedes 6/2011 picture goes here THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE REFERENCE NOTICE
More informationELECTRONIC COMMUNICATING THERMOSTAT
O M N I S T A T ELECTRONIC COMMUNICATING THERMOSTAT Installation Manual RC-81 Single Stage Heat/Cool Real Time Pricing System Document Number 13I00-2 January, 1997 Copyright 1997 Home Automation, Inc.
More informationVAPOR-LOGIC MICROPROCESSOR BASED HUMIDIFIER CONTROL SYSTEM
READ AND SAVE THESE INSTRUCTIONS VAPOR-LOGIC MICROPROCESSOR BASED HUMIDIFIER CONTROL SYSTEM Installation, Start-Up, and Operations Manual For Toll-free Technical Support, call 1-800-328-4447. Have the
More informationLynergy Comfort Control SCR Electric Heater Application Guide
AG-Lynergy-2 September 18, 217 Lynergy Comfort Control SCR Electric Heater Application Guide Titus Redefine your comfort zone. www.titus-hvac.com 65 Shiloh Road Plano, Texas 7574 972.212.4 Titus, the Titus
More informationF PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.
F-2000 PC and AO OUTPUT BOARDS INSTRUCTION MANUAL Blue-White R Industries, Ltd. 500 Business Drive Huntington Beach, CA 92649 USA Phone: 714-89-8529 FAX: 714-894-9492 E mail: sales@blue-white.com or techsupport@blue-white.com
More informationOperating Instructions. For. Alarm Control Module. Model SSR 500
SSR 500 LEVEL CONTROL RELAY MODULE Operating Instructions For Alarm Control Module Model SSR 500 SSR Operation Instructions Rev. 1 Jan 01 Page 1/7 1. Note Please read and take note of these operating instructions
More informationInstallation Instructions
2 or 4 pipe systems model T701DFP-1 Fan Coil Thermostat 7-Day Programmable Thermostat Remote sensor ready Self-prompting programming Auto 2-pipe changeover when used with accessory changeover sensor Dry
More informationGS-2. Instruction Manual. G-Series Cooler. Manual is for the following model: GS-2 GS-2-013EB GS-2-N13EB GS-2-P23EB GS-2-Z23EB COUNTERTOP COOLER
G-Series Cooler GS- COUNTERTOP COOLER anual is for the following model: GS- GS--013EB GS--N13EB GS--P3EB GS--Z3EB nstruction anual anual is for the following model: GS- GS--013EB GS--N13EB GS--P3EB GS--Z3EB
More informationOVEN INDUSTRIES, INC.
OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-252 TEMPERATURE CONTROLLER With PLC Inputs Introduction Thank you for purchasing our controller. The Model 5C7-252 is an exceptionally versatile unit and
More informationFAN POWERED VAV TERMINALS
FAN POWERED VAV TERMINALS Models VFR, CFR and CFRQ INSTALLATION, OPERATION AND MAINTENANCE MANUAL All data herein is subject to change without notice. Refer to www.enviro-tec.com for current catalog data
More informationInterchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F
Temperature Controller 1/16 DIN Sized Controller Offers Selectable Control, Alarm Modes Accurate to ±0.5% of full scale Multiple temperature scale ranges allow flexibility to match application Field-selectable
More informationFire Safety. Installation Instructions Model MMB-2 Main Control Board OPERATION. INSTALLATION Always remove power before installation.
Fire Safety nstallation nstructions Model MMB- Main ontrol Board OPERATON The SEMENS Model MMB- board in each MXL System controls operations and monitors input device identity, network communication, and
More informationINSTALLER S & OWNER S MANUAL
INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000R Part No. 4028407 Dehumidifier & Ventilation System Controller 4201 Lien Road, Madison, WI 53704 TOLL-FREE (800)-533-7533
More informationVA301C CONTROLLER WITH BACnet OPTION
ORDERING INFORMATION VA301C Controller VA301C-DLC VA301C-DLC-BIP Gas detection controller with data logging, display and plastic housing. Gas detection controller with data logging and display, BACnet/IP
More informationE340 BOILER CONTROL INSTALLATION MANUAL
E-3451 JUNE 1999 E340 BOILER CONTROL INSTALLATION MANUAL DESCRIPTION The E340 Boiler Room Control is a microprocessor-based Boiler Management System designed to interface with existing Fireye D Series
More informationApplications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements
INDEX 1 NETIC... 2 2 Door/Window detector MINI... 2 3 FOUR sensor... 3 4 Smoke detector... 3 5 Flood detector... 4 6 ILLumination sensor... 4 7 Lamp holder... 5 8 Siren... 5 9 Power meter & switch... 6
More informationTempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications
Instruction Manual Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications Manual PCT-3000 Revision 9/2014 The PCT-3000 series control console incorporates
More informationUser's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT
User's Manual Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dualoutput Types) Thank you for purchasing the JUXTA Signal Conditioner. Please read through this
More informationELP21LU3-LF-HLOL THREE CHANNEL
ELP21LU3-LF-HLOL THREE CHANNEL 516-467-5787 HI LEVEL LOW LEVEL LEAK DETECTION 11.00 TEST SYSTEM DETECTING HORN OFF 6.00 SPECIFICATIONS POWER INPUT 85-125 VAC, 47-440 Hz 16 Watts maximum POWER TO SENSORS
More informationNIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE
O P E R A T I N G I N S T R U C T I O N S NIR-50-325 RETROREFLECTIVE PHOTOEYE U L 3 2 5-2 0 1 8 M O N I T O R E D DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales
More informationHoneywell HumidIcon Digital Humidity/Temperature Sensors. HIH9000 Series ±1.7 %RH Accuracy. Datasheet
Honeywell HumidIcon Digital Humidity/Temperature Sensors HIH9000 Series ±.7 %RH Accuracy Datasheet Honeywell HumidIcon Digital Humidity/Temperature Sensors Honeywell HumidIcon Digital Humidity/Temperature
More information