Swimming Pool. Ventilation. Solving swimming pool ventilation issues and providing energy saving solutions. f Design assistance for new installations
|
|
- Gerald Blankenship
- 5 years ago
- Views:
Transcription
1 Swimming Pool Ventilation Design assistance or new installations High eiciency custom designed air handling system or energy savings through reduced heating demand Intelligent controls or maximum lexibility and perormance Energy saving evaluations and problem solving or existing installations Reurbish and upgrade existing equipment in-situ Comprehensive installation assistance package Swimming Pool Unit Solving swimming pool ventilation issues and providing energy saving solutions
2 Swimming Pool Ventilation design... create... leisure environments leisure centres Swimming Pool Environment Correct swimming pool ventilation is one o the most critical elements in the successul and economic running o a leisure centre. Poorly designed systems will cost operators thousands o pounds unnecessarily. VES can assist designers to prevent this with new installations or oer solutions to existing installations, substantially reducing running costs and energy consumption. Water evaporation rom a pool is inevitable and can cause poor air quality and building damage i it isn t properly managed. Relative humidity needs to be controlled to create the right conditions or both users and operators o a pool. VES will investigate and then tailor a package that gives the best conditions and the most economic running costs. We will work with you to meet your budget requirements. schools Swimming pools are inherently expensive to run, typically accounting or over hal the budget o a leisure centre
3 HIGH EFFICIENCY, LOW ENERGY SWIMMING POOL SOLUTIONS Ventilation Process To maintain optimum, comortable conditions, a swimming pool requires a ventilation process that can control temperature and humidity. To maximise energy savings, VES pool air handling units use a heat recovery plate heat exchanger and integrated mixing section to recover up to 85% o energy that would otherwise be lost. VES swimming pool packages are ideal or leisure centres, schools and other commercial establishments. Our portolio o projects is extensive see the case studies on the inside back cover. More can be ound at hotels
4 Swimming Pool Ventilation Swimming Pool Handling Units A high eiciency AHU lies at the heart o every VES pool ventilation system. The VES range is designed speciically to meet the unique demands o a swimming pool environment. Designed and manuactured in the UK, VES AHUs conorm to the latest manuacturing standards including L2 Building Regulations and are tested in accordance with BS848 Part 1 or air side perormance and DIN or acoustic perormance. What s more, the high eiciency VES pool AHU is designed to reduce heating demand, minimising the need or supplementary heating with R Standard Features 50 mm insulated double skinned panels or improved thermal and acoustic perormance Epoxy powder coat paint inish (RAL7004) to internal and external panel suraces or extended durability Plate heat exchanger heat recovery section with integrated air mixing acility to optimise energy savings IP66 damper actuators to guarantee reliability Glands itted to cable entry and exit points to prevent moisture ingress Compressible synthetic rubber door seals to eliminate panel air leakage Fitted eliminators to prevent moisture carry over into air stream Powder coated drain pans itted to heat exchanger to ensure water condensate is removed eectively Fan speed automatically regulates in accordance with humidity and temperature demand Control package based on a Siemens platorm to enable energy tuning which maximises cost savings Options Built in or duct mounted attenuators Weatherprooed pitched roo on external models Case Construction DX or chilled water cooling Choice o colour
5 HIGH EFFICIENCY, LOW ENERGY SWIMMING POOL SOLUTIONS Key Components Key components o the AHU have been careully selected and come with the ollowing eatures as standard. 1 Heat Recovery 3 High Perormance Fans 5 Plate heat exchanger is generously sized to achieve a minimum eiciency o 70% Virgin plastic or anodised matrix resistant to the aggressive chlorinated air Fully integrated mixing section with by-pass Powder coated drain trays Direct driven centriugal plug ans Polycarbonate resin or epoxy powder coated steel impellers Epoxy powder coated rame Speed controlled by a requency inverter Pressure dierential switch Spring anti-vibration mounts 23 4 The plate heat exchanger section incorporates our independently controlled ace and by-pass dampers to acilitate accurate temperature and humidity control Powder coated damper blade Polyurethane intermeshing gears IP66 damper actuators Heating Coil Filtration Face and By-Pass Dampers Heating provided by an LPHW coil Copper tube with poly coated ins Epoxy powder coated steel casework Matched three port control valve and actuator Panels Filters are itted to both supply and extract sections o the AHU 100 mm deep ARP rigid pleat panel Wax treated moisture resistant rame Grade M6 as standard Fixed and access panels are constructed rom high grade galvanised sheet steel Epoxy powder coated paint inish to RAL 7004 High density mineral wool inill or greater thermal perormance BlueSense Energy Saving Package = Swimming pool unit with integral controls EC an - with ull control Sensor options The sign o energy saving products, services and expertise
6 Swimming Pool Ventilation Modes o Operation All modes are automatic with no input required rom the end user. Sensors constantly monitor humidity and temperature, sending signals to the control system to adjust internal dampers and an speed to meet the individual demands o the pool. Each mode is seamless and conigured to maintain optimum conditions quietly and eiciently. Recirculation Mode When the pool is not in use, typically night time, ans automatically adjust to a lower speed and the AHU adopts ull recirculation mode with a nominal amount o resh air input to maintain conditions. Return Supply Full Fresh Mode Higher bather numbers during the summer months naturally increases humidity. Dampers on the ace o the plate heat exchanger close while by-pass dampers open to adopt a ull resh air mode. Fresh Return Exhaust Supply Winter Mode A smaller proportion o resh air passes through the heat exchanger and mixes with a higher proportion o recirculated air rom the pool. This is heated by the LPHW heating coil when additional demand or heating is required. Fresh Exhaust Return Supply Normal Mode Heat is recovered rom the pool by passing air over the plate heat exchanger. This heat is transerred to incoming resh air. A proportion o air is recirculated back into the supply air stream to prevent unnecessary evaporation rom the pool. Fresh Exhaust Return Supply
7 HIGH EFFICIENCY, LOW ENERGY SWIMMING POOL SOLUTIONS The VES Pools Package or new equipment We are experienced designers o pool hall systems and have developed a design programme to maximise energy savings which shows payback times that are oten less than 18 months New build or an existing pool hall? For new build projects we can provide ull design assistance including unit selection, ductwork layout and air distribution. On existing systems, pool hall units present an entirely dierent set o challenges: The pool will already be operational and disruption or any shutdown periods need to be kept to an absolute minimum. Our experience shows that AHUs are normally located within tight plantrooms that includes boilers, water treatment and other associated plant leaving little room or any air-handling works, be that replacement or reurbishment. Hurlingham Club, London The example picture here shows a very restricted plantroom at the amous Hurlingham Club where we carried out extensive works on the swimming pool plant To help overcome all these issues we can oer the VES Pools Package This includes the ollowing works and services to help ensure a smooth and trouble ree project is delivered a) We will work with the project team to produce a programme o works that will ensure downtime and disruption are kept to an absolute minimum. We may be able to keep the pool open with the use o temporary ventilation or working out o hours, meaning no loss o revenue b) We will undertake ull on-site technical measurements and then design a unit that perectly its the available space, taking ull responsibility or correct it and handings c) Rip-out o the old unit d) New site latpack or sectional installation e) Commissioning o the unit and controls once installed All this adds up to a successul, trouble ree installation
8 Swimming Pool Ventilation Or reurbish your existing AHU or a cost eective solution VES pioneered and is the market leader in on-site reurbishment o existing air-handling equipment regardless o make or model The pictures below illustrate various stages o an air handling unit reurbishment. Unit condition beore Beore - dampers siezed Ater - replacement dampers and actuators Beore - ineicient belt driven ans Ater - new energy eicient plug an Completed reurbished unit We can oten upgrade a unit, increasing its duty and perormance We will undertake a ree survey and produce a ully detailed and costed quotation detailing the works that we can oer We will also highlight any energy saving measures that can be included in our reurbishment works Typically, the cost o reurbishment is ar lower than replacing with new. Reurbishment is oten a quicker and more lexible approach to replacing. The works can also be undertaken out o hours meaning less potential down time, which is absolutely essential or a leisure centre Areas with potential or reurbishment Casework Roo Heating and controls Gas burners Dampers Filters Fans
9 HIGH EFFICIENCY, LOW ENERGY SWIMMING POOL SOLUTIONS VES Pool Ventilation in action Case study - energy saving, ast payback Situation The acilities maintenance contractor asked VES to review the state o the existing equipment and installation and make recommendations to improve the conditions and or energy savings. The swimming pool supply and extract air-handling equipment was in poor condition, with no heat recovery at all. We also ound un-lagged heating ductwork. Solution VES engineers assisted the contractor with site works, including: Installing a brand new supply and extract AHU with a high-eiciency crosslow heat exchanger Manuacturing and itting new controls with inverters that automatically reduce the an speed out o hours Aluclad lagging heating ductwork to minimise heat loss Replacing another unit serving the gym with a heat recovery AHU located on the same platorm All craneage plus cutting up and removing the old equipment Outcome The addition o heat recovery and other energy saving measures made such a substantial impact on heating demand that the main pool direct gas ired heater could be downrated rom 250 kw to a 100 kw heater - a huge 60% reduction! Overall, the project resulted in substantial energy savings and a payback period o just 3 years. Other case studies A range o case studies showing how VES have helped leisure centres save energy and optimise perormance can be ound on our website. Read more at sssales@ves.co.uk
10 Specialist Site Services Other products and services rom the VES oers a wide range services including: complete range ooves HVAC solutions: Assistance with design and layout o ventilation systems Energy saving and payback calculations Flatpack supply and installation service where space is limited Reurbishment options o existing equipment including integration o new energy saving technologies Commissioning and post installation service Evaluate energy savings available and oer a costed dilapidation report Noise reduction and air quality improvement or existing systems Site surveys Kitchen ventilation Controls design and installation Maintenance and Spares Handling Units: Duct Fans: Twin Fans: Roo Extract Units: Wall and Ceiling Fans: Kitchen Hood Extract Fans: Control Panels: Noise Control: Specialist Site Services: VES Head Oice Eagle Close, Chandlers Ford Industrial Estate, Chandlers Ford, Eastleigh, Hampshire SO53 4NF Tel: +44 (0) Fax: +44 (0) VES Manchester Oice Unit 6, Willan Enterprise Centre, 4th Avenue, The Village, Traord Park, Manchester M17 1DB Tel: +44 (0) Fax: +44 (0) VES Glasgow Oice 2010 VES Andover Ltd. ISO 9001:2008 Unit 15, Evans Business Centre,Issue Springhill Business Park, Glasgow G69 6GA No. Q05375 CC01 - Parkway, 01/2010 GlasgowCert. Tel: +44 (0) Fax: +44 (0) VES reserve the right to amend product speciications and details without notice. sssales@ves.co.uk VES reserves the right to amend product speciications and details without notice. VES Andover Ltd Eagle Close, Chandlers Ford Industrial Estate, Chandlers Ford, Eastleigh, Hampshire SO53 4NF I ino@ves.co.uk Tel: SPV I Fax: 2014 VES Issue - 07/2014
HIGH EFFICIENCY HEAT RECOVERY
HIGH EFFICIENCY HEAT RECOVERY low energy ans itted controls with touch screen remote wide range o models or ceiling void, plantroom and outdoor location L2 compliant classroom unit All units suitable or
More informationSAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts
Small Air Handling units SAM W i d e d u t y r a n g e 0.05m 3 /sec to 2.4m 3 /sec Powerful yet quiet Extensive options VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products
More information0.4 m 3 /s. Plastic and Steel cased fan Units. Round Fans. Latest EC Fan Technology. Compact and Powerful. Easy to install
Round Fans compliant Round Fans DUTIES UP TO 0.4 m 3 /s Plastic and Steel cased fan s Latest E Fan Technology ompact and Powerful Easy to install Range of accessories and solutions Round Fans part of a
More informationQuality Products AHU Repair, Refurbishment and Replacement
Quality Products AHU Repair, Refurbishment and Replacement We are engineers specialising in the repair, refurbishment and replacement of ventilation systems. We have considerable experience in solving
More informationHeat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools
Heat Recovery Dehumidification (HRD) system Designed for municipal swimming pools A dehumidification and ventilation system with dynamic heat pump heat recovery to swimming pool water and air ENVIRONMENTAL
More information... DF / IDF Gas fired combined heating and ventilation ...
DF / IDF Gas fired combined heating and ventilation Gas fired combined heating and ventilation Introduction The comprehensive range of gas fired air handling units provides high efficiency combined heating
More informationDF-IDF air handling units
APPLICATIONS Heating, ventilation >> WAREHOUSES >> DISTRIBUTION CENTRES >> FACTORIES >> SPORTS HALLS >> EXHIBITION HALLS DF-IDF air handling units www.reznor.eu DF - IDF air handling units GAS FIRED COMBINED
More informationCI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION
CI/SfB 56.83 X DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION Introduction Nordair Niche is one of the UK's leading specialists in
More informationCOOLING and DE-HUMIDIFICATION WITHOUT USING REFRIGERANTS
COOLING and DE-HUMIDIFICATION WITHOUT USING REFRIGERANTS THE DAWN OF A NEW ERA Political and ecological pressures over the past few years, have led to a change of emphasis in the design of fully air-conditioned
More informationPRODUCT RANGE POOL AIR HANDLING UNITS. Swimming pool and spa environmental control, heating, cooling and dehumidification
PRODUCT RANGE POOL AIR HANDLING UNITS Swimming pool and spa environmental control, heating, cooling and dehumidification ABOUT THE DANTHERM GROUP Control your climate The Dantherm Group is a leading provider
More informationGemini EC. Engineered with Excellence, Specified with Confidence All-in-One Renewable Energy Climate Control
Gemini EC 1000-12000 All-in-One Renewable Energy Climate Control - Integral Aerothermal fresh air source heat pump boiler - Integral dual function dehumidifying and expelled room air heat pump - Direct-Contact
More informationCaice Attenuator Selector - Specifier Edition
Fan Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels Efficiency Energy Saving Heating Cooling Fan Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels
More informationPRODUCT RANGE POOL AIR HANDLING UNITS. Swimming pool and spa environmental control, heating, cooling and dehumidification
PRODUCT RANGE POOL AIR HANDLING UNITS Swimming pool and spa environmental control, heating, cooling and dehumidification ABOUT THE DANTHERM GROUP Control your climate The Dantherm Group is a leading provider
More informationDouble Skin Air Handling Units
Double Skin Air Handling Units With Screwless Cabinets Engineered to Deliver High Indoor Air Quality Double Skin Air Handling Units from the Experts Blue Star has over six decades of experience in offering
More informationAir Handling Units. Real HVACR people who understand your needs.
Air Handling Units Real HVACR people who understand your needs. Copyright HC Heat-Exchangers (PTY) Ltd. 1 Copyright HC Heat-Exchangers (PTY) Ltd. 2 About the HC AHU range HC Heat-Exchangers rich engineering
More informationEVH Hybrid Ventilation Unit
VES Ref. ID.1425 February 2017 This manual must be read in full before Installation, Operation and Maintenance of the units supplied Please ensure that this document is passed to the end user. This manual
More informationPREEVA EC Gas Fired Heating, Ventilation & Cooling Units
... PREEVA EC Gas Fired Heating, Ventilation & Cooling Units... ErP 2018 ErP Lot 21 Seasonal Efficiency and Nx compliant ErP 2018 ErP Lot 21 Seasonal Efficiency and Nx compliant PREEVA EC... Gas Fired
More informationDouble Skin Air Handling Units
Double Skin Air Handling Units With Screwless Cabinets Engineered to Deliver High Indoor Air Quality Double Skin Air Handling Units from the Experts Blue Star has over six decades of experience in offering
More informationAir Handling Units. direct drive - belt drive - custom built
for fresher air Air Handling Units direct drive - belt drive - custom built Vectaire Ltd is a member of: ; Fan Manufacturers Association; Smoke Control Association; Residential Ventilation Association;
More informationLTV - LTV-N Air Handling Unit
Air Handling Unit Aluminium. According EN 12101 www.bovema.nl Mechanical ventilation. Heating. Cooling. Filtration. Heat recovery. Recirculation. Wetting. Dehumidification. S-air International B.V. Hogelandseweg
More information39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range
PRODUCT SELECTION DATA Plug & play unit (built-in control) Class A+ across entire range Classic/Vertical/ceiling-mounted dualflow units High-efficiency heat recovery unit High performance plug fan High-efficiency
More informationAir Handling Units. direct drive - belt drive - custom built
for fresher air Air Handling Units direct drive - belt drive - custom built Vectaire Ltd is a member of: ; Fan Manufacturers Association; Smoke Control Association; Residential Ventilation Association;
More informationFLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.
The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution use Air flow rate: 500 to 8500 m 3 /h is a PLUG & PLAY dual-flow ventilation unit equipped with a highly
More informationAIR HANDLING UNITS MANDÍK
AIR HANDLING UNITS MANDÍK 2 CONTENTS MANDÍK, a. s. The Company... 3 Photo Gallery... 4 Unit Description... 6 Air handling unit parameters according to Eurovent... 7 Product Range of the Air Handling Units...
More informationCLIMACIAT AIR COMPACT
Air handling units The modular and ultra-slim AHU to guarantee perfect solution Ideal for a compact installation Available in single-flow or aligned or adjacent dual-flow versions Air flow: up to 6 000
More informationCompact. Efficient. TROX.
Compact. Efficient. TROX. The art of handling air TROX understands the art of handling air like no other company. Since its foundation in 1951, TROX has been developing and manufacturing sophisticated
More informationTrane Performance Climate Changer Air Handlers. An air handler for every need.
Trane Performance Climate Changer Air Handlers An air handler for every need. Trane Performance Climate Changer air handlers: designed to optimize your HVAC system. Trane Performance Climate Changer air
More informationBENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS
BENSN... EnviroAir Gas Fired Heating, Ventilation & Cooling Units... AMBIRAD HEATI NG AND VENTILATIN S LUTINS EnviroAir... Gas Fired Heating, Ventilation & Cooling Units... The Benson EnviroAir is a new
More informationVERSO Air Handling Units
Energy efficient solutions for profitable indoor climate VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P air handling units equipped with recuperation system
More informationecovent NRGP Air Handling Units
VES Ref. ID.880b April 2011 This manual must be read in full before Installation, Operation and Maintenance of the units supplied Please ensure that this document is passed to the end user. This manual
More informationPFS Single stage axial fan The axial fan for modern boiler plants
PFS Single stage axial fan The axial fan for modern boiler plants This large axial fan, type PFS- 400-236, was installed in 1987 at the Salmisaari coal-fired power station in Helsinki, Finland. The photo
More informationEnergy Efficiency HOSPITALITY.
Energy Efficiency HOSPITALITY www.energia.ie Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could make a real
More informationLIBERTY COMPOSITE AIR HANDLING UNITS TYPE LIBERTY > SWIMMING POOLS. AHU No Liberty AIR HANDLING UNITS
LIBERTY COMPOSITE AIR HANDLING UNITS TYPE LIBERTY > SWIMMING POOLS AIR HANDLING UNITS AHU No 15.11.007 Liberty Future proof The air handling unit supplies fresh outdoor air to the swimming pool in order
More informationThe power of ventilation
The power of ventilation LindabAir Handling Unit Ensure the correct flow of fresh air, acceleration at the right rate and exact volume lindab.com 1 lindab air handling units Air Handling Units that maximise
More informationDaikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel
Daikin Applied UK Technically better... D-AHU Modular R Air handling units Compact air handling unit with heat recovery wheel Energy efficiency and air quality With their Plug & Play design and inherent
More informationETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT
90% EFFICIENCY HIGHEST EFFICIENCY AIR HANDLING UNIT Packaged energy recovery solutions for Green Buildings Integrated Accumulator, controls and DX Cooling System CLEAN AIR SINCE 1963 Euroclima is a company
More informationIf a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.
Air handling units Aesthetic Not to add significantly to the existing ambient noise levels. Functional requirements If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally
More informationIngersoll Rand kw Single Stage Contact-cooled rotary screw air compressors
Ingersoll Rand 37-75 kw Single Stage Contact-cooled rotary screw air compressors Reliability and Energy Efficiency at Your Fingertips Ingersoll Rand Competing in today s business environment requires manufacturers
More informationSmoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking
Smoke Control Ducts and Dampers For Single Compartment Applications Fulfilling new requirements for EN product standards for CE Marking New Smoke Control Product Range Fläkt Woods Smoke Control Ducts and
More informationPremium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units
Premium Efficiency Heat Recovery Unit D-AHU Modular L Air Handling Units About Daikin Our promise is to ensure that customers can depend on Daikin for the ultimate in comfort, so that they are free to
More informationAIR HANDLING UNITS. Handling air like nobody else.
Handling air like nobody else AIR HANDLING UNITS T: 0113 218 6100 F: 0113 218 6101 E: sales@sovereignairmovement.co.uk www.sovereignairmovement.co.uk Unit B National Court, Fox Way, Off Atkinson Street,
More informationDouble Skin Casing Air Handling Units
Double Skin Casing Air Handling Units Double wall with 25 mm insulation Modular design for clean process application flexibility all the requirements 2,000 40,000 CFM AUTUMN Air Handling Units incorporate
More informationCenteral Station Air Handling Unit
Centeral Station Air Handling Unit CA Series www.windind.com www.windind.com The product range includes double skinned Air Handling Units, double skinned Fan Coil Units, and custom designed packaged roof
More informationType PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS
Homepage > Products > Fancoil units > Type PWX Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS Nominal sizes 60, 90, 120, 150, 180 and 205 Volume flow rate range
More informationof environmental a product range engineering excellence PR1 ISSUE 2 HEADQUARTERS Dalair Limited Southern Way Wednesbury West Midlands WS10 7BU
PR1 ISSUE 2 JULY 2001 a product range of environmental engineering excellence HEADQUARTERS Dalair Limited Southern Way Wednesbury West Midlands WS10 7BU Website: www.dalair.co.uk email: sales@dalair.co.uk
More informationSPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module
SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:
More informationDanvent DV 190 and 240
Fans Air Handling Units Air Distribution Products Air Conditioning Fire Safety Air Curtains and Heating Products Tunnel Fans Danvent DV 190 and 240 Air Handling Units with High Capacity Danvent DV 190
More informationTrane Performance Climate Changer Air Handlers. An air handler for every need.
Trane Performance Climate Changer Air Handlers An air handler for every need. Trane Performance Climate Changer air handlers: The most comprehensive air-handler portfolio in the industry. The portfolio
More informationSMOKE CONTROL - NEW DIRECTIONS
SMOKE CONTROL - NEW DIRECTIONS Nuaire provides the total package for smoke control with schemes designed to fully comply with statutory and regulatory requirements. Our team of skilled engineers include
More informationThe ultimate in air handling units: directly and indirectly fired
AHU The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake
More informationOptimal work climate with open doors. Industrial air curtains Model IndAC
Optimal work climate with open doors Industrial air curtains Model IndAC Industrial air curtain Optimal work climate During loading and unloading the door remains open, without the indoor climate being
More informationTECHNICAL INFORMATION DanX Swimming Pool Air Management
TECHNICAL INFORMATION DanX Swimming Pool Air Management Der tages forbehold for trykfejl og ændringer Dantherm can accept no responsibility for possible errors and changes Irrtümer und Änderungen vorbehalten
More informationCOOLflow 4E PRODUCT RANGE
COOLflow 4E PRODUCT RANGE FREE AIR COOLING FROM THE FREE AIR SPECIALISTS GUARANTEED TO SIGNIFICANTLY REDUCE CARBON EMISSIONS & DELIVER ENERGY SPEND SAVINGS OF UP TO 95% The COOLflow 4E range has been developed
More informationSPACE CONDITIONING IN COMMERCIAL BUILDINGS Overview
SPACE CONDITIONING IN COMMERCIAL BUILDINGS Overview As in residential buildings the purpose of mechanical conditioning and ventilation is to maintain air quality and thermal comfort in buildings, with
More informationVERSO Air Handling Units
VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO Air Handling Units VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P
More informationAIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT
AIR TREATMENT ReCOOLER HP ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT Energy efficiency the essence of our solutions All our research, development
More informationKOMFORT EC DB Suspended heat recovery air handling units
2018 AIR HANDLING UNITS KOMFORT EC DB Suspended heat recovery air handling units Features Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings.
More informationSystemair product news - Fans NEWS
Systemair product news - Fans NEWS Perfect Climate. Anywhere. Anytime Smart, energy-saving solutions for ventilation and air-conditioning. Well-thought-out system solutions for every application area.
More informationAIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)
AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory
More informationCaice Attenuator Selector - Specifier Edition
Fan Coil Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels Efficiency Energy Saving Prestige Attenuation Controls Package Plenum Heating Cooling Fan Coil Unit Acoustic Performance
More informationNew rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018
New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1 Extensive option package included in all models ErP compliant 2018 3 years warranty Daikin rooftops Flexible to suit your application Rooftop for Retail & Department
More informationSmoke extract fan SMHA HATCH
12.11.2012 Contents Product overview... 3 Construction... 4 Specification... 5 Selection... 6 Installation... 7 Electrical connections... 8 Dimensions and weights... 9 Product code and accessories... 10
More informationAir handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses
REC Temovex 4S-EC-RS Experts on indoor climate in low-energy houses RT 4S-EC-RS REC Temovex 4S-EC-RS ECO2 control system for low-energy and passive houses Comprises: - Air flow boost for warm and cold
More informationThe ultimate in air handling units: directly and indirectly fired
AHU The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake
More informationHeat Exchanger Excellence DESIGN BUILD SUPPLY INSTALL MAINTAIN.
Heat Exchanger Excellence DESIGN BUILD SUPPLY INSTALL MAINTAIN www.heatxforce.co.uk We are committed to providing industry with the latest technology, consistent high quality, outstanding reliability and
More informationGüntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility
Güntner Info GVX with microox technology 6 525 kw Always a step ahead: microox condenser system with maximum installation flexibility The new standard for flexibility, technology Energy-saving operation
More informationHomepage > Products > Decentralised ventilation Systems > Vertical devices > Type FSL-V-ZUS. Type FSL-V-ZUS
Homepage > Products > Decentralised ventilation Systems > Vertical devices > Type FSL-V-ZUS Type FSL-V-ZUS SECONDARY AIR UNIT FOR SUPPLY AIR, WITH HEAT EXCHANGER, FOR VERTICAL INSTALLATION ON AN EXTERNAL
More informationwww.ecso-klimatechnik.de ECSO GMBH Wetterssteimstr. 53 D- 90471,.. Nurnberg, Deutschland e-mail: info@ecso-klimatechnik.de Tel/Fax: +49 (0) 911/818 9917 TABLE OF SYMBOLS OPERATING MODE OPTIONS VENTILATION
More informationKyros TM is: Flexible to perform in a range of applications. Reliable proven technology you can trust. Usable easy to install, operate and manage
Automated Wireless Food Biomedical Monitoring is the third generation o Digitron s acclaimed automatic biomedical monitoring system, building on the capabilities, beneits, experience and knowledge derived
More informationOperating Performance
INFORMATION SHEET 1 Jackson Engineering Advisers are specialist Building Services Engineers. This information sheet is offered as an aid to Building Owners and Managers as a guide to plant life expectancies.
More informationX-Stream Air Natural Ventilation kits are predominantly designed for self-installation. Suitable for ventilating existing and new build applications.
X- StreamSystems X-Stream Air Natural Ventilation kits are predominantly designed for self-installation. Suitable for ventilating existing and new build applications. Contact us on: 01384 455811 Visit
More informationEasdale International INFINITY
Easdale International INFINITY Air flow from 800 to 0.000 m 3 /h APPLIED SYSTEM AIR HANDLING UNITS AHU N : 0.0.502 Range: Easdale International www.eurovent-certification.com www.certiflash.com Engineered
More informationIndirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160)
Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160) About Climate Wizard Climate Wizard s unique indirect evaporative heat exchange core provides hyper-efficient cooling of outside air.
More informationABOUT US OUR EXPERTISE WHAT IS ENERGY RECOVERY? ERV (Energy Recovery Ventilation) AHU (Air Handling Units) PAC (Package Air Conditioning Equipment)
COMPANY PROFILE ABOUT US THE LEADERS IN AIR TO AIR HEAT RECOVERY. ARMCOR AIR SOLUTIONS IS A DYNAMIC, PROFESSIONAL COMPANY RESPECTED BY THE AIR CONDITIONING INDUSTRY FOR OUR TRACK RECORD IN PROVIDING ADVICE,
More informationTopMaster Air Handling unit. Technical data
Technical data Contents Page Description of the unit... 3 Design... 4 Technical data Size 030... 5 Size 0... 6 Accessories... 7 Controls... 9 Control functions... 10 Order codes... 11 Fläkt Woods 8180
More informationDAIKIN Air Handling Unit Modular
DAIKIN Air Handling Unit Modular Compact ventilation unit with heat recovery Energy efficiency and air quality Daikin air handling units, with their plug-and-play design and inherent flexibility, can be
More informationAegean Range. A new range of fan coils for heating and cooling commercial applications
egean Range new range of fan coils for heating and cooling commercial applications How Fan Coils work Fan Coils provide heating and cooling solutions for a wide range of applications. Fan Coil Unit (FCU)
More informationHIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%
Dry HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES Calculation of savings (for illustrative purposes) Operating scheme Note: power rates refer to 10,000 m 3 /h of air and
More informationAir Handling Unit Airblock FG
Air Handling Unit Airblock FG Twice as powerful with Twin technology Twin technology helps to ensure optimised air flow and excellent power density from such a shallow design. The modular system concept
More informationAir Handling Units. direct drive - belt drive - custom built
for fresher air Air Handling Units direct drive - belt drive - custom built Vectaire Ltd is a member of: ; Fan Manufacturers Association; Smoke Control Association; Residential Ventilation Association;
More informationSeries. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:
RL Packaged Rooftop Units, heat pumps and Outdoor air handling Units Features: Air-cooled condenser, water-cooled condenser, or patented AAON evaporative-cooled condenser, with capacities from 45-240 tons
More informationThe ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER
The ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER Kelvion a tribute to Lord Kelvin Lord Kelvin (1824 1907) formulated the laws of thermodynamics 70 branches and sales partners
More informationAIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!
AIR HANDLING UNITS RIS P EKO 3.0 1 2 3 4 fans! Efficient EC E f f i c i e n c y up to 94%! E x t r e m e l y low height! New range - 5 sizes, 20 models! Contents Basic features 4 RIS P EKO 3.0 full range
More informationCLIMACIAT. air HanDLIng UnIT: CLIMaCIaT. Air handling unit
AHU for all applications Designed to meet the EN 13053 and EN 1886 standards The effective solution for service sector, industry and healthcare applications air HanDLIng UnIT: CLIMaCIaT represents the
More informationSWIMMING POOL AIR MANAGEMENT DanX
SWIMMING POOL AIR MANAGEMENT DanX SWIMMING POOL AIR MANAGEMENT Comfortable swimming in every climate It is impossible to avoid water evaporation in swimming pool halls, however using a carefully designed
More informationTEC Coolers. GEA Heat Exchangers. GEA Searle
TEC Coolers GEA Heat Exchangers GEA Searle Quality and Performance making the difference Quality and Performance Eurovent Certification All applicable products are certified under the Eurovent CERTIFYALLprogram,
More informationEnriching Environments
Enriching Environments 2 Enriching Environments We understand the difference an improved internal environment can make 3 Contents 4 5 6 7 8 9 10 11 About us Heating and cooling coils Fan convectors Trench
More informationRotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar COMPRESSORS
COMPRESSORS Rotary Screw Compressors ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar www.kaeser.com ASK series ASK Maximum performance Powerful and
More informationMechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system
Viewpoint August 2012 Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system Dr Sarah Price and Helen Brown Summary Mechanical Ventilation and Heat
More informationUnit heater with accessories
LVD Unit Heater Unit heater with accessories The type LVDV fan-assisted unit heaters are designed for space heating in shop entrances, lobbies, doorways, warehouses and workshops, garages and similar premises.
More informationFUME EXTRACT STRATEGY STATEMENT
FUME EXTRACT STRATEGY STATEMENT : New Islington Free School No: 7/4781 The site is located in central Manchester on an area of disused land adjacent to the Rochdale canal. The site forms a roughly rectangular
More informationCaice Attenuator Selector - Specifier Edition
Fan Coil Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels Efficiency Energy Saving Prestige Attenuation Controls Package Plenum Heating Cooling Fan Coil Unit Acoustic Performance
More informationAIR CONDITIONING & VENTILATION PLANTS
H E A T R E C O V E R Y AIR CONDITIONING & VENTILATION PLANTS DANTHERM THE EXPERTS IN VE INTERNAL CLIMATE For many people, the majority of their time is spent indoors. It is thus essential that the internal
More informationTopVent Design Handbook
TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit
More informationRotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar.
Rotary Screw Compressors ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar www.kaeser.com ASK series ASK Maximum performance Discerning users expect
More informationClean Air Laminar Flow Ceiling CG 3 A CLEAN AIR WORLD. Draft-free, comfortable room climate. Minimal, undisruptive noise level
Clean Air Laminar Flow Ceiling CG 3 Ultra Clean Ventilation System with Unidirectional Flow Draft-free, comfortable room climate Minimal, undisruptive noise level Easy to disinfect housing design with
More informationCompact SLIM. Air cooler GASC. Air coolers in a flat design with forced draught fans Optimal for commercial cooling. HFCs, CO 2 0.
INFO SLIM Compact Air cooler GASC Air coolers in a flat design with forced draught fans Optimal for commercial cooling HFCs, CO 2 0.6 14 kw Air coolers for small cold rooms The ideal solution for small
More informationCI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS
CI/SfB 56.83 X EnviroPak Series GAS FIRED HEATING, VENTIATIN AND CING UNITS EnviroPak Series GAS FIRED HEATING, VENTIATIN AND CING UNITS Introduction The Reznor EnviroPak is a new generation of gas fired
More informationCZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with
More informationAdsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system
Comfort air conditioning 56/58 Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system 58 3 0 - simplified illustration Automatically selects the most economical
More information