Submitted to: For Reference Approval Construction

Size: px
Start display at page:

Download "Submitted to: For Reference Approval Construction"

Transcription

1 SUBITTAL DATA: SEZ-KD9A & SUZ-KA9A , BTU/H HORIZOTAL-DUCTED HEAT-PUP SYSTES Job ame: Location: Date: Purchaser: Engineer: Submitted to: For Reference Approval Construction System Designation: Schedule o.: GEERAL FEATURES Horizontal-ducted indoor unit for concealed Ultra thin body: -/8" high Built-in drain mechanism for condensate removal; lifts to 21-11/16" filter is included with indoor unit Quiet operation as low as 23 dba Indoor unit powered from outdoor unit using A-Control Automatic fan speed control Auto restart following a power outage ed warranty: five years on parts/defects; seven years on compressors Indoor Unit: SEZ-KD9A Outdoor Unit: SUZ-KA9A OPTIOAL ACCESSORIES Indoor Unit Filter Box with ERV 8 Filters (FBL1-1) Bottom Return Plate (BRP-1) Outdoor Unit Drain Socket (AC-86DS) Drain Pan Heater (AC-6BH-U) Three-pole Disconnect Switch (TAZ-S3) Outlet Guide (AC-856SG) ounting Base (DSD-) ounting Pad (ULTRILITE1) Wall-mounting Brackets (CWB1) Controller Options Wall-mounted Wired Remote Controller (PAR-21AA) -ET Control Adapter (AC-399IF) Remote Temperature Sensor (21-JKO-) Hand-held Wireless Remote Controller (PAR-FL32A; req.par-fa32a-e) Wireless Signal Receiver odule PAR-FA32A (for PAR-FL32A-E) Lockdown Bracket for Hand-held Controller (RCKP1CB) Cooling* Rated Capacity....8,1 Btu/h Capacity Range...3,8-1,9 Btu/h SEER Total Input....6 W Heating at 4 F* Rated Capacity....1,9 Btu/h Capacity Range...4,8-14,1 Btu/h HSPF Total Input....1, W Heating at 1 F* Rated Capacity....6, Btu/h Rated Total Input...81 W aximum Capacity....6, Btu/h aximum Total Input...1, W *Rating Conditions (Cooling)-Indoor: 8ºF(2ºC)DB, 6ºF(19ºC)WB; Outdoor: 95ºF(35ºC)DB, 5ºF(24ºC)WB. (Heating at 4ºF) - Indoor: ºF (21ºC) DB, 6ºF (16ºC) WB; Outdoor: 4ºF (8ºC) DB, 43ºF (6ºC) WB. (Heating at 1ºF) - Indoor: ºF (21ºC) DB, 6ºF (16ºC) WB; Outdoor: 1ºF (-8ºC) DB, 15ºF (-9ºC) WB. Electrical Requirements Power Supply...8 / 2V, 1-Phase, 6 Hz Recommended Fuse/Breaker Size A OPERATIG CODITIOS Indoor Intake Temp. Outdoor Intake Temp. aximum 9 F (32 C) DB, 3 F (23 C) WB 115 F (46 C) DB Cooling inimum 6 F (19 C) DB, 5 F (14 C) WB 14 F (-1 C) DB aximum 8 F (2 C) DB, 6 F (19 C) WB 5 F (24 C) DB, 65 F (18 C) WB Heating inimum F (21 C) DB, 6 F (16 C) WB -4 F (- C) DB, -5 F (-21 C) WB 11 ITSUBISHI ELECTRIC & ELECTROICS, IC. Voltage Indoor - Outdoor S1-S2...AC 8 / 2V Indoor - Outdoor S2-S3...DC 12-24V Indoor Unit CA...1 A Fan Type x Quantity...Sirocco Fan x 2 Fan otor Type... Direct-driven DC Brushless otor Fan otor Output...96 W Fan otor...51 F.L.A. flow (Lo - ed - Hi) Dry CF Wet CF Filter...Polypropylene Honeycomb External Static Pressure "WG Sound Pressure Level (Lo - ed - Hi) db(a) DIESIOS UIT ICHES / W 31-1/8 / 9 D 2-9/16 / H -/8 / Weight lbs. / 19 kg External Finish...Galvanized-steel Sheets Field Drainpipe Size O.D /4" / 32 mm Outdoor Unit Compressor...DC Inverter-driven CA...12 A OCP A Fan otor...5 F.L.A. Sound Pressure Level Cooling...46 db(a) Heating...5 db(a) DIESIOS ICHES / W 31-1/2 / 8 D 11-1/4 / 285 H 21-5/8 / 55 Weight...66 lbs. / kg External Finish... unsell o. 3Y.8 / 1.1 Refrigerant Type...R41A Refrigerant Pipe Size O.D. Gas Side...3/8" / 9.52 mm Liquid Side....1/4" / 6.35 mm ax. Refrigerant Pipe Length ' / 19 m ax. Refrigerant Pipe Height Difference... ' / 12 m Connection ethod...flared

2 SEZ-KD9A IDOOR FA PERFORACE AD CORRECTED AIR FLOW CHARTS IDOOR FA PERFORACE AD CORRECTED AIR FLOW SEZ-KD9A (External static pressure.2[in.wg](5pa)) 8/2V 6Hz [.16] SEZ-KD9A (External static pressure.6[in.wg](15pa)) 8/2V 6Hz 5 [.] [.8] 1 [.4] [.16] [.8] 1 [.4] [141] [16] [212] [24] [282] [318] [353] [141] [16] [212] [24] [282] [318] [353] SEZ-KD9A (External static pressure.14[in.wg](35pa)) 8/2V 6Hz 8 [.32] [.28] 6 [.24] 5 [.] [.16] [.8] 1 [.4] [141] [16] [212] [24] [282] [318] [353] SEZ-KD9A (External static pressure.[in.wg](5pa)) 8/2V 6Hz 8 [.32] [.28] 6 [.24] 5 [.] [.16] [.8] 1 [.4] [141] [16] [212] [24] [282] [318] [353] 11 ITSUBISHI ELECTRIC & ELECTROICS, IC.

3 DIESIOS: SEZ-KD9A 345(13-19/32) (Emergency draining) Unit : mm(in.) 159(6-9/32) 15(19/32) 2XE-ø2.9(1/8) Suspension bolt hole 4-14X(9/16X1-3/16) Slot L-ø2.9(1/8) (13/16) 3(1-15/32) 1(3-15/16) 15.5(6-/32) 3(1-15/32) 25(1) 5(2-1/4) D (Duct) 1(3-15/16)X(E-1)=F 1(3-15/16) outlet inlet A B (Suspension bolt pitch) C H 1(3-15/16)XJ=K 1(3-15/16) 5(2-1/4) 15(Duct) (5-29/32) (13/16) (1-3/16) 1 25(1) (3-15/16) 116 (4-19/32) 2X2-ø2.9(1/8) 1 Refrigerant piping flare connection (gas) 1(13/32) (Suspension bolt pitch) (1-15/16) (24-5/8) 1(13/32) (2-25/32) 2(1-21/32) 2 Refrigerant piping flare connection (liquid) (2-9/16) 6(26-21/32) Control box 12(4-1/32) 1(6-23/32) 9 (3-9/16) (-/8) (Indoor/outdoor connecting line) (Remote controller transmission line) Terminal block (Indoor/outdoor connecting line) Terminal block (Remote controller transmission line) (Spontaneous draining) (13/16) filter ote2 5(1-31/32) 5(1-31/32) G 45 5 ~ 15 (1-31/32 ~ 5-29/32) 45 (-19/32) 15±5(6-29/32±/32) (Actual length) ore than Required space for service and maintenance Less than Less than 55 (21-21/32) ore than 1 (13/32) ore than (13/16) Drain hose (I.D.ø32(1-1/4)) <accessory> Ceiling surface ake the access door at the appointed position properly for service maintenance. odel A B C D SEZ-KD9A (2-9/16) (29-5/8) (31-/16) (26) (35-/16) (3-1/2) (39-5/16) (33-/8) F G 6 8 (23-5/8) (31-1/2) H 66 (26) (31-1/2) (39-3/8) (33-/8) (43-5/16) (45-3/8) (4-3/16) (41-3/4) 11 (39-3/8) (4-1/4) (41-3/4) 9 ote1.use 1 screw for the suspension bolt (field supply). 2.Keep the service space for the maintenance at the bottom. 3.This chart indicates for model,which has 3 fans. SEZ-KD9,12A models have 2 fans. models have 4 fans. 4.In case an inlet duct is used,remove the air filter(supply with the unit), then install the filter(field supply) at suction side. E 9 J 5 K 5 (19-11/16) (2-9/16) 9 (35-/16) L (33-1/16) 139 (-29/32) 1239 (48-25/32) 9 (31-1/8) 99 (39) 119 (46-/8) mm(in.) 1 Gas pipe 2 Liquid pipe ø9.52(3/8) ø6.35(1/4) ø12.(1/2) 11 ITSUBISHI ELECTRIC & ELECTROICS, IC.

4 DIESIOS: SUZ-KA9A FOR# SEZ-KD9A & SUZ-KA9A ITSUBISHI ELECTRIC & ELECTROICS, IC. 3 Lawrenceville Suwanee Rd Suwanee, GA 24 Tele: Fax: Toll Free: (#3) Specifications are subject to change without notice.

5 SUBITTAL DATA: & SUZ-KA12A , BTU/H HORIZOTAL-DUCTED HEAT-PUP SYSTES Job ame: Location: Date: Purchaser: Engineer: Submitted to: For Reference Approval Construction System Designation: Schedule o.: GEERAL FEATURES Horizontal-ducted indoor unit for concealed applications Ultra thin body: -/8" high Built-in drain mechanism for condensate removal; lifts to 21-11/16" filter is included with indoor unit Quiet operation as low as 23 dba Indoor unit powered from outdoor unit using A-Control Automatic fan speed control Auto restart following a power outage ed warranty: five years on parts/defects; seven years on compressors Indoor Unit: Outdoor Unit: SUZ-KA12A OPTIOAL ACCESSORIES Indoor Unit Filter Box with ERV 8 Filters (FBL1-2) Bottom Return Plate (BRP-2) Outdoor Unit Drain Socket (AC-86DS) Drain Pan Heater (AC-6BH-U) Three-pole Disconnect Switch (TAZ-S3) Outlet Guide (AC-856SG) ounting Base (DSD-) ounting Pad (ULTRILITE1) Wall-mounting Brackets (CWB1) Controller Options Wall-mounted Wired Remote Controller (PAR-21AA) -ET Control Adapter (AC-399IF) Remote Temperature Sensor (21-JKO-) Hand-held Wireless Remote Controller (PAR-FL32A;req.PAR-FA32A-E) Wireless Signal Receiver odule PAR-FA32A (for PAR-FL32A) Lockdown Bracket for Hand-held Controller (RCKP1CB) Cooling* Rated Capacity....11,5 Btu/h Capacity Range...3,8-13, Btu/h SEER Total Input....9 W Heating at 4 F* Rated Capacity....13,6 Btu/h Capacity Range...4,8-16, Btu/h HSPF Total Input....1,1 W Heating at 1 F* Rated Capacity....9, Btu/h Rated Total Input...9 W aximum Capacity....9, Btu/h aximum Total Input...1,18 W *Rating Conditions (Cooling)-Indoor: 8ºF(2ºC)DB, 6ºF(19ºC)WB; Outdoor: 95ºF(35ºC)DB, 5ºF(24ºC)WB. (Heating at 4ºF) - Indoor: ºF (21ºC) DB, 6ºF (16ºC) WB; Outdoor: 4ºF (8ºC) DB, 43ºF (6ºC) WB. (Heating at 1ºF) - Indoor: ºF (21ºC) DB, 6ºF (16ºC) WB; Outdoor: 1ºF (-8ºC) DB, 15ºF (-9ºC) WB. Electrical Requirements Power Supply...8 / 2V, 1-Phase, 6 Hz Recommended Fuse/Breaker Size A OPERATIG CODITIOS Indoor Intake Temp. Outdoor Intake Temp. aximum 9 F (32 C) DB, 3 F (23 C) WB 115 F (46 C) DB Cooling inimum 6 F (19 C) DB, 5 F (14 C) WB 14 F (-1 C) DB aximum 8 F (2 C) DB, 6 F (19 C) WB 5 F (24 C) DB, 65 F (18 C) WB Heating inimum F (21 C) DB, 6 F (16 C) WB -4 F (- C) DB, -5 F (-21 C) WB 11 ITSUBISHI ELECTRIC & ELECTROICS, IC. Voltage Indoor - Outdoor S1-S2...AC 8 / 2V Indoor - Outdoor S2-S3... DC 12-24V Indoor Unit CA...1 A Fan Type x Quantity...Sirocco Fan x 2 Fan otor Type... Direct-driven DC Brushless otor Fan otor Output...96 W Fan otor...5 F.L.A. flow (Lo - ed - Hi) Dry CF Wet CF Filter...Polypropylene Honeycomb External Static Pressure "WG Sound Pressure Level (Lo - ed - Hi) db(a) DIESIOS UIT ICHES / W 39 / 99 D 2-9/16 / H -/8 / Weight....5 lbs. / 22 kg External Finish...Galvanized-steel Sheets Field Drainpipe Size O.D /4" / 32 mm Outdoor Unit Compressor...DC Inverter-driven CA...12 A OCP A Fan otor...5 F.L.A. Sound Pressure Level Cooling...49 db(a) Heating...51 db(a) DIESIOS ICHES / W 31-1/2 / 8 D 11-1/4 / 285 H 21-5/8 / 55 Weight... lbs. / 35 kg External Finish... unsell o. 3Y.8 / 1.1 Refrigerant Type...R41A Refrigerant Pipe Size O.D. Gas Side...3/8" / 9.52 mm Liquid Side....1/4" / 6.35 mm ax. Refrigerant Pipe Length ' / 19 m ax. Refrigerant Pipe Height Difference... ' / 12 m Connection ethod...flared

6 IDOOR FA PERFORACE AD CORRECTED AIR FLOW CHARTS (External static pressure.2[in.wg](5pa)) 8/2V 6Hz [.16] (External static pressure.6[in.wg](15pa)) 8/2V 6Hz 5 [.] [.8] 1 [.4] [.16] [.8] 1 [.4] [212] [24] [282] [318] [353] [388] [424] [212] [24] [282] [318] [353] [388] [424] (External static pressure.14[in.wg](35pa)) 8/2V 6Hz 8 [.32] [.28] 6 [.24] 5 [.] [.16] [.8] 1 [.4] [212] [24] [282] [318] [353] [388] [424] (External static pressure.[in.wg](5pa)) 8/2V 6Hz 8 [.32] [.28] 6 [.24] 5 [.] [.16] [.8] 1 [.4] [212] [24] [282] [318] [353] [388] [424] 11 ITSUBISHI ELECTRIC & ELECTROICS, IC.

7 DIESIOS: 345(13-19/32) (Emergency draining) Unit : mm(in.) 159(6-9/32) 15(19/32) 2XE-ø2.9(1/8) Suspension bolt hole 4-14X(9/16X1-3/16) Slot L-ø2.9(1/8) (13/16) 3(1-15/32) 1(3-15/16) 15.5(6-/32) 3(1-15/32) 25(1) 5(2-1/4) D (Duct) 1(3-15/16)X(E-1)=F 1(3-15/16) outlet inlet A B (Suspension bolt pitch) C H 1(3-15/16)XJ=K 1(3-15/16) 5(2-1/4) 15(Duct) (5-29/32) (13/16) (1-3/16) 1 25(1) (3-15/16) 116 (4-19/32) 2X2-ø2.9(1/8) 1 Refrigerant piping flare connection (gas) 1(13/32) (Suspension bolt pitch) (1-15/16) (24-5/8) 1(13/32) (2-25/32) 2(1-21/32) 2 Refrigerant piping flare connection (liquid) (2-9/16) 6(26-21/32) Control box 12(4-1/32) 1(6-23/32) 9 (3-9/16) (-/8) (Indoor/outdoor connecting line) (Remote controller transmission line) Terminal block (Indoor/outdoor connecting line) Terminal block (Remote controller transmission line) (Spontaneous draining) (13/16) filter ote2 5(1-31/32) 5(1-31/32) G 45 5 ~ 15 (1-31/32 ~ 5-29/32) 45 (-19/32) 15±5(6-29/32±/32) (Actual length) ore than Required space for service and maintenance Less than Less than 55 (21-21/32) ore than 1 (13/32) ore than (13/16) Drain hose (I.D.ø32(1-1/4)) <accessory> Ceiling surface ake the access door at the appointed position properly for service maintenance. odel A B C D SEZ-KD9A (2-9/16) (29-5/8) (31-/16) (26) (35-/16) (3-1/2) (39-5/16) (33-/8) F G 6 8 (23-5/8) (31-1/2) H 66 (26) (31-1/2) (39-3/8) (33-/8) (43-5/16) (45-3/8) (4-3/16) (41-3/4) 11 (39-3/8) (4-1/4) (41-3/4) 9 ote1.use 1 screw for the suspension bolt (field supply). 2.Keep the service space for the maintenance at the bottom. 3.This chart indicates for model,which has 3 fans. SEZ-KD9,12A models have 2 fans. models have 4 fans. 4.In case an inlet duct is used,remove the air filter(supply with the unit), then install the filter(field supply) at suction side. E 9 J 5 K 5 (19-11/16) (2-9/16) 9 (35-/16) L (33-1/16) 139 (-29/32) 1239 (48-25/32) 9 (31-1/8) 99 (39) 119 (46-/8) mm(in.) 1 Gas pipe 2 Liquid pipe ø9.52(3/8) ø6.35(1/4) ø12.(1/2) 11 ITSUBISHI ELECTRIC & ELECTROICS, IC.

8 DIESIOS: SUZ-KA12A FOR# & SUZ-KA12A ITSUBISHI ELECTRIC & ELECTROICS, IC. 3 Lawrenceville Suwanee Rd Suwanee, GA 24 Tele: Fax: Toll Free: (#3) Specifications are subject to change without notice.

9 SUBITTAL DATA: & SUZ-KA15A , BTU/H HORIZOTAL-DUCTED HEAT-PUP SYSTES Job ame: Location: Date: Purchaser: Engineer: Submitted to: For Reference Approval Construction System Designation: Schedule o.: GEERAL FEATURES Horizontal-ducted indoor unit for concealed applications Ultra thin body: -/8" high Built-in drain mechanism for condensate removal; lifts to 21-11/16" filter is included with indoor unit Quiet operation as low as 23 dba Indoor unit powered from outdoor unit using A-Control Automatic fan speed control Auto restart following a power outage ed warranty: five years on parts/defects; seven years on compressors Indoor Unit: Outdoor Unit: SUZ-KA15A OPTIOAL ACCESSORIES Indoor Unit Filter Box with ERV 8 Filters (FBL1-2) Bottom Return Plate (BRP-2) Outdoor Unit Drain Socket (AC-86DS) Drain Pan Heater (AC-6BH-U) Three-pole Disconnect Switch (TAZ-S3) Outlet Guide (AC-856SG) ounting Base (DSD-) ounting Pad (ULTRILITE1) Wall-mounting Brackets (CWB1) Controller Options Wall-mounted Wired Remote Controller (PAR-21AA) -ET Control Adapter (AC-399IF) Remote Temperature Sensor (21-JKO-) Hand-held Wireless Remote Controller (PAR-FL32A;req.PAR-F 32A-E) Wireless Signal Receiver PAR-FA32A (for PAR-FL32A-E) Lockdown Bracket for Hand-held Controller (RCKP1CB) Cooling* Rated Capacity....14,1 Btu/h Capacity Range...3,8-1, Btu/h SEER Total Input....1,1 W Heating at 4 F* Rated Capacity....18, Btu/h Capacity Range...4,8-21,1 Btu/h HSPF Total Input....1,5 W Heating at 1 F* Rated Capacity....11,9 Btu/h Rated Total Input...1, W aximum Capacity....11,9 Btu/h aximum Total Input...1,65 W *Rating Conditions (Cooling)-Indoor: 8ºF(2ºC)DB, 6ºF(19ºC)WB; Outdoor: 95ºF(35ºC)DB, 5ºF(24ºC)WB. (Heating at 4ºF) - Indoor: ºF (21ºC) DB, 6ºF (16ºC) WB; Outdoor: 4ºF (8ºC) DB, 43ºF (6ºC) WB. (Heating at 1ºF) - Indoor: ºF (21ºC) DB, 6ºF (16ºC) WB; Outdoor: 1ºF (-8ºC) DB, 15ºF (-9ºC) WB. Electrical Requirements Power Supply...8 / 2V, 1-Phase, 6 Hz Recommended Fuse/Breaker Size A OPERATIG CODITIOS Indoor Intake Temp. Outdoor Intake Temp. aximum 9 F (32 C) DB, 3 F (23 C) WB 115 F (46 C) DB Cooling inimum 6 F (19 C) DB, 5 F (14 C) WB 14 F (-1 C) DB aximum 8 F (2 C) DB, 6 F (19 C) WB 5 F (24 C) DB, 65 F (18 C) WB Heating inimum F (21 C) DB, 6 F (16 C) WB -4 F (- C) DB, -5 F (-21 C) WB Voltage Indoor - Outdoor S1-S2...AC 8 / 2V Indoor - Outdoor S2-S3... DC 12-24V Indoor Unit CA...1 A Fan Type x Quantity...Sirocco Fan x 3 Fan otor Type... Direct-driven DC Brushless otor Fan otor Output...96 W Fan otor...4 F.L.A. flow (Lo - ed - Hi) Dry CF Wet CF Filter...Polypropylene Honeycomb External Static Pressure "WG Sound Pressure Level (Lo - ed - Hi) db(a) DIESIOS UIT ICHES / W 39 / 99 D 2-9/16 / H -/8 / Weight lbs. / 24 kg External Finish...Galvanized-steel Sheets Field Drainpipe Size O.D /4" / 32 mm Outdoor Unit Compressor...DC Inverter-driven Twin Rotary CA...12 A OCP A Fan otor...5 F.L.A. Sound Pressure Level Cooling...49 db(a) Heating...51 db(a) DIESIOS ICHES / W 31-1/2 / 8 D 11-1/4 / 285 H 21-5/8 / 55 Weight...8 lbs. / 36 kg External Finish... unsell o. 3Y.8 / 1.1 Refrigerant Type...R41A Refrigerant Pipe Size O.D. Gas Side...1/2" / 12. mm Liquid Side....1/4" / 6.35 mm ax. Refrigerant Pipe Length ' / 19 m ax. Refrigerant Pipe Height Difference... ' / 12 m Connection ethod...flared 11 ITSUBISHI ELECTRIC & ELECTROICS, IC.

10 IDOOR FA PERFORACE AD CORRECTED AIR FLOW CHARTS (External static pressure.2[in.wg](5pa)) 8/2V 6Hz [.16] (External static pressure.6[in.wg](15pa)) 8/2V 6Hz 5 [.] [.8] 1 [.4] [.16] [.8] 1 [.4] [282] [318] [353] [388] [424] [459] [494] [5] [565] [282] [318] [353] [388] [424] [459] [494] [5] [565] (External static pressure.14[in.wg](35pa)) 8/2V 6Hz 8 [.32] [.28] 6 [.24] 5 [.] [.16] [.8] 1 [.4] [282] [318] [353] [388] [424] [459] [494] [5] [565] (External static pressure.[in.wg](5pa)) 8/2V 6Hz 8 [.32] [.28] 6 [.24] 5 [.] [.16] [.8] 1 [.4] [282] [318] [353] [388] [424] [459] [494] [5] [565] 11 ITSUBISHI ELECTRIC & ELECTROICS, IC.

11 DIESIOS: 345(13-19/32) (Emergency draining) Unit : mm(in.) 159(6-9/32) 15(19/32) 2XE-ø2.9(1/8) Suspension bolt hole 4-14X(9/16X1-3/16) Slot L-ø2.9(1/8) (13/16) 3(1-15/32) 1(3-15/16) 15.5(6-/32) 3(1-15/32) 25(1) 5(2-1/4) D (Duct) 1(3-15/16)X(E-1)=F 1(3-15/16) outlet inlet A B (Suspension bolt pitch) C H 1(3-15/16)XJ=K 1(3-15/16) 5(2-1/4) 15(Duct) (5-29/32) (13/16) (1-3/16) 1 25(1) (3-15/16) 116 (4-19/32) 2X2-ø2.9(1/8) 1 Refrigerant piping flare connection (gas) 1(13/32) (Suspension bolt pitch) (1-15/16) (24-5/8) 1(13/32) (2-25/32) 2(1-21/32) 2 Refrigerant piping flare connection (liquid) (2-9/16) 6(26-21/32) Control box 12(4-1/32) 1(6-23/32) 9 (3-9/16) (-/8) (Indoor/outdoor connecting line) (Remote controller transmission line) Terminal block (Indoor/outdoor connecting line) Terminal block (Remote controller transmission line) (Spontaneous draining) (13/16) filter ote2 5(1-31/32) 5(1-31/32) G 45 5 ~ 15 (1-31/32 ~ 5-29/32) 45 (-19/32) 15±5(6-29/32±/32) (Actual length) ore than Required space for service and maintenance Less than Less than 55 (21-21/32) ore than 1 (13/32) ore than (13/16) Drain hose (I.D.ø32(1-1/4)) <accessory> Ceiling surface ake the access door at the appointed position properly for service maintenance. odel A B C D SEZ-KD9A (2-9/16) (29-5/8) (31-/16) (26) (35-/16) (3-1/2) (39-5/16) (33-/8) F G 6 8 (23-5/8) (31-1/2) H 66 (26) (31-1/2) (39-3/8) (33-/8) (43-5/16) (45-3/8) (4-3/16) (41-3/4) 11 (39-3/8) (4-1/4) (41-3/4) 9 ote1.use 1 screw for the suspension bolt (field supply). 2.Keep the service space for the maintenance at the bottom. 3.This chart indicates for model,which has 3 fans. SEZ-KD9,12A models have 2 fans. models have 4 fans. 4.In case an inlet duct is used,remove the air filter(supply with the unit), then install the filter(field supply) at suction side. E 9 J 5 K 5 (19-11/16) (2-9/16) 9 (35-/16) L (33-1/16) 139 (-29/32) 1239 (48-25/32) 9 (31-1/8) 99 (39) 119 (46-/8) mm(in.) 1 Gas pipe 2 Liquid pipe ø9.52(3/8) ø6.35(1/4) ø12.(1/2) 11 ITSUBISHI ELECTRIC & ELECTROICS, IC.

12 DIESIOS: SUZ-KA15A FOR# & SUZ-KA15A ITSUBISHI ELECTRIC & ELECTROICS, IC. 3 Lawrenceville Suwanee Rd Suwanee, GA 24 Tele: Fax: Toll Free: (#3) Specifications are subject to change without notice.

13 SUBITTAL DATA:...18, BTU/H HORIZOTAL-DUCTED IDOOR UIT FOR XZ-B ULTI-ZOE HEAT-PUP SYSTES Job ame: Location: Date: Purchaser: Engineer: Submitted to: For Reference Approval Construction System Designation: Schedule o.: GEERAL FEATURES Horizontal-ducted indoor unit for concealed applications Ultra thin body: -/8" high Built-in drain mechanism for condensate removal; lifts to 21-11/16" filter is included with indoor unit Quiet operation as low as 23 dba Indoor unit powered from outdoor unit using A-Control Automatic fan speed control Auto restart following a power outage ed warranty: five years on parts/defects; seven years on compressors OPTIOAL ACCESSORIES Indoor Unit Filter Box with ERV 8 Filters (FBL1-3) Bottom Return Plate (BRP-3) Outdoor Unit Drain Socket (AC-811DS) Drain Pan Heater (AC-641BH-U) Three-pole Disconnect Switch (TAZ-S3) Outlet Guide (AC-856SG) ounting Base (DSD-) ounting Pad (ULTRILITE1) Wall-mounting Brackets (CWB1) Controller Options Wall-mounted Wired Remote Controller (PAR-21AA) -ET Control Adapter (AC-399IF) Remote Temperature Sensor (21-JKO-) Hand-held Wireless Remote Controller (PAR-FL32A; eq.par-fa32a-e) Wireless Signal Receiver odule PAR-FA32A (for PAR-FL32A) Lockdown Bracket for Hand-held Controller (RCKP1CB) Cooling Capacity*....1, Btu/h Heating Capacity at 4 F*...21,6 Btu/h * Rating Conditions (Cooling) - Indoor: 8ºF (2ºC) DB, 6ºF (19ºC) WB; Outdoor: 95ºF (35ºC) DB, 5ºF (24ºC) WB. (Heating at 4ºF) - Indoor: ºF (21ºC) DB, 6ºF (16ºC) WB; Outdoor: 4ºF (8ºC) DB, 43ºF (6ºC) WB. (Heating at 1ºF) - Indoor: ºF (21ºC) DB, 6ºF (16ºC) WB; Outdoor: 1ºF (-8ºC) DB, 15ºF (-9ºC) WB. Electrical Requirements Power Supply...8 / 2V, 1-Phase, 6 Hz CA... 1 A SZ-GE SEZ and PEAD-A24AA Indoor Unit: Voltage Indoor - Outdoor S1-S2...AC 8 / 2V Indoor - Outdoor S2-S3... DC 12-24V Fan otor...4 F.L.A. flow (Lo - ed - Hi) Cooling Dry CF Wet CF Heating Dry CF Sound Pressure Level (Lo - ed - Hi) Cooling db(a) Heating db(a) DIESIOS UIT ICHES / W 46-/8 / 1,19 D 2-9/16 / H -/8 / Weight lbs. / 28 kg External Finish...Galvanized-steel Sheets Field Drainpipe Size O.D /4" / 32 mm Refrigerant Type...R41A Refrigerant Pipe Size O.D. Gas Side...1/2" / 12. mm Liquid Side....1/4" / 6.35 mm Connection ethod...flared XZ-B SERIES HEAT-PUP OUTDOOR UITS ULTI-ZOE OUTDOOR UIT XZ-B ULTI-ZOE SYSTES CA ICLUDE: Ducted Indoor Units: SEZ-KD9,12,15,18A, PEAD-A24AA onducted Indoor Units: SZ-GE6,9,12,15,18,24A, SZ-FE9,12,18A, FZ-KA9,12,18A, PCA-A24KA, SLZ-KA9,12,15A, and PLA-A12,18,24BA A combination of both Ducted and onducted Indoor Units Refer to the separate submittal forms for the SZ-GE, SZ-FE, FZ-KA, SEZ-KD, SLZ-KA, PEAD, PCA, PLA Indoor Units, and XZ Outdoor Units. SZ-FE FZ-KA PCA-A24KA SLZ and PLA-A12,18,24BA 11 ITSUBISHI ELECTRIC & ELECTROICS, IC.

14 IDOOR FA PERFORACE AD CORRECTED AIR FLOW CHARTS (External static pressure.2[in.wg](5pa)) 8/2V 6Hz [.16] [.8] 1 [.4] [318] [353] [388] [424] [459] [494] [5] [565] [6] [636] [61] (External static pressure.6[in.wg](15pa)) 8/2V 6Hz 5 [.] [.16] [.8] 1 [.4] [318] [353] [388] [424] [459] [494] [5] [565] [6] [636] [61] (External static pressure.14[in.wg](35pa)) 8/2V 6Hz 8 [.32] [.28] 6 [.24] 5 [.] [.16] [.8] 1 [.4] [318] [353] [388] [424] [459] [494] [5] [565] [6] [636] [61] (External static pressure.[in.wg](5pa)) 8/2V 6Hz 8 [.32] [.28] 6 [.24] 5 [.] [.16] [.8] 1 [.4] [318] [353] [388] [424] [459] [494] [5] [565] [6] [636] [61] 11 ITSUBISHI ELECTRIC & ELECTROICS, IC.

15 DIESIOS: 159(6-9/32) 15(19/32) 2XE-ø2.9(1/8) 345(13-19/32) (Emergency draining) Suspension bolt hole 4-14X(9/16X1-3/16) Slot L-ø2.9(1/8) (13/16) 3(1-15/32) 1(3-15/16) 15.5(6-/32) 3(1-15/32) Unit : mm(in.) 25(1) 5(2-1/4) D (Duct) 1(3-15/16)X(E-1)=F 1(3-15/16) outlet inlet A B (Suspension bolt pitch) C H 1(3-15/16)XJ=K 1(3-15/16) 15(Duct) (5-29/32) (13/16) (1-3/16) 1 25(1) (3-15/16) 5(2-1/4) 116 (4-19/32) 2X2-ø2.9(1/8) 1 Refrigerant piping flare connection (gas) 1(13/32) (Suspension bolt pitch) (1-15/16) (24-5/8) 1(13/32) (2-25/32) 2(1-21/32) (2-9/16) 6(26-21/32) Control box 2 Refrigerant piping flare connection (liquid) 12(4-1/32) 1(6-23/32) 9 (3-9/16) (-/8) (Indoor/outdoor connecting line) (Remote controller transmission line) Terminal block (Indoor/outdoor connecting line) Terminal block (Remote controller transmission line) (Spontaneous draining) (13/16) filter ote2 5(1-31/32) 5(1-31/32) G 45 5 ~ 15 (1-31/32 ~ 5-29/32) 45 (-19/32) 15±5(6-29/32±/32) (Actual length) ore than Required space for service and maintenance Less than Less than 55 (21-21/32) ore than 1 (13/32) Drain hose (I.D.ø32(1-1/4)) <accessory> ore than (13/16) Ceiling surface ake the access door at the appointed position properly for service maintenance. odel A B C D SEZ-KD9A (2-9/16) (29-5/8) (31-/16) (26) (35-/16) (3-1/2) (39-5/16) (33-/8) F G H (23-5/8) (31-1/2) (26) (31-1/2) (39-3/8) (33-/8) (43-5/16) (45-3/8) (4-3/16) (41-3/4) 11 (39-3/8) (4-1/4) (41-3/4) 9 ote1.use 1 screw for the suspension bolt (field supply). 2.Keep the service space for the maintenance at the bottom. 3.This chart indicates for model,which has 3 fans. SEZ-KD9,12A models have 2 fans. models have 4 fans. 4.In case an inlet duct is used,remove the air filter(supply with the unit), then install the filter(field supply) at suction side. E 9 J K 5 5 (19-11/16) (2-9/16) 9 (35-/16) L (33-1/16) 139 (-29/32) 1239 (48-25/32) 9 (31-1/8) 99 (39) 119 (46-/8) mm(in.) 1 Gas pipe 2 Liquid pipe ø9.52(3/8) ø6.35(1/4) ø12.(1/2) FOR# ITSUBISHI ELECTRIC & ELECTROICS, IC. 3 Lawrenceville Suwanee Rd Suwanee, GA 24 Tele: Fax: Toll Free: (#3) Specifications are subject to change without notice.

M-SERIES SUBMITTAL DATA: SEZ-KD15NA4** & SUZ-KA15NA. Job Name: Location: Date: Submitted to: For Reference Approval Construction

M-SERIES SUBMITTAL DATA: SEZ-KD15NA4** & SUZ-KA15NA. Job Name: Location: Date: Submitted to: For Reference Approval Construction SUBMITTAL DATA: ** & SUZ-KA15NA 15, BTU/H HORIZONTAL-DUCTED HEAT-PUMP SYSTEMS M-SERIES Job Name: Location: Date: Purchaser: Engineer: Submitted to: For Reference Approval Construction System Designation:

More information

SUBMITTAL DATA: SLZ-KA09NA... 9,000 BTU/H CEILING-CASSETTE INDOOR UNIT FOR MXZ-B MULTI-ZONE HEAT-PUMP SYSTEMS

SUBMITTAL DATA: SLZ-KA09NA... 9,000 BTU/H CEILING-CASSETTE INDOOR UNIT FOR MXZ-B MULTI-ZONE HEAT-PUMP SYSTEMS SUBMITTAL DATA: SLZ-KA9NA......... 9, BTU/H CEILING-CASSETTE INDOOR UNIT FOR MXZ-B MULTI-ZONE HEAT-PUMP SYSTEMS Job Name: Location: Date: Purchaser: Engineer: Submitted to: For Reference Approval Construction

More information

SUBMITTAL DATA: SLZ-KA09NA & SUZ-KA09NA 9,000 BTU/H CEILING-CASSETTE HEAT-PUMP SYSTEMS. Cooling 4. Heating

SUBMITTAL DATA: SLZ-KA09NA & SUZ-KA09NA 9,000 BTU/H CEILING-CASSETTE HEAT-PUMP SYSTEMS. Cooling 4. Heating M-SERIES SUBMITTAL DATA: SLZ-KA09NA & SUZ-KA09NA 9,000 BTU/H CEILING-CASSETTE HEAT-PUMP SYSTEMS Job Name: System Reference: Date: ENERGY STAR...Yes ENERGY STAR products are third-party certified by an

More information

SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7 P-SERIES SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PEAD-A42AA7 PUZ-A42NKA7 PUZ-A42NKA7-BS

More information

SUBMITTAL DATA: PEAD-A30AA7 & PUZ-A30NHA7(-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A30NHA7

SUBMITTAL DATA: PEAD-A30AA7 & PUZ-A30NHA7(-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A30NHA7 P-SERIES SUBMITTAL DATA: PEAD-A30AA7 & (-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM Job Name: System Reference: Indoor Unit: PEAD-A30AA7 Date: Outdoor Unit: -BS INDOOR UNIT FEATURES Unobtrusive

More information

SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7

SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7 P-SERIES SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PEAD-A12AA7 PUZ-A12NKA7 PUZ-A12NKA7-BS

More information

SUBMITTAL DATA: PEAD-A24AA7 & PUY-A24NHA7(-BS) 24,000 BTU/H HORIZONTAL-DUCTED AIR-CONDITIONING SYSTEM. Job Name: System Reference:

SUBMITTAL DATA: PEAD-A24AA7 & PUY-A24NHA7(-BS) 24,000 BTU/H HORIZONTAL-DUCTED AIR-CONDITIONING SYSTEM. Job Name: System Reference: P-SERIES SUBMITTAL DATA: & PUY-A24NHA7(-BS) 24,000 BTU/H HORIZONTAL-DUCTED AIR-CONDITIONING SYSTEM Job Name: System Reference: : Date: : PUY-A24NHA7 PUY-A24NHA7-BS INDOOR UNIT FEATURES Unobtrusive ceiling-concealed

More information

SUBMITTAL DATA: MSZ-FH06NA & MUZ-FH06NA 6,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM. Electrical Power Requirements. Indoor / Outdoor A 1 / 11

SUBMITTAL DATA: MSZ-FH06NA & MUZ-FH06NA 6,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM. Electrical Power Requirements. Indoor / Outdoor A 1 / 11 M-SERIES SUBMITTAL DATA: MSZ-FH0NA & MUZ-FH0NA,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM Job Name: System Reference: Date: Electrical Power Requirements 08 / 30V, -Phase, 0 Hz ACCESSORIES: Unit Unit: MSZ-FH0NA

More information

SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7

SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7 P-SERIES SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: PCA-A24KA7 Outdoor Unit: PUZ-A24NHA7 PUZ-A24NHA7-BS

More information

SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7 P-SERIES SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PVA-A42AA7 PUZ-A42NKA7 PUZ-A42NKA7-BS INDOOR

More information

SUBMITTAL DATA: PVA-A36AA7 & PUZ-HA36NHA5 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference:

SUBMITTAL DATA: PVA-A36AA7 & PUZ-HA36NHA5 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: P-SERIES SUBMITTAL DATA: & 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM Job Name: System Reference: Date: : : INDOOR UNIT FEATURES Ducted air handler provides a solution to cool and heat large zones Highly

More information

SUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A36NKA7

SUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A36NKA7 P-SERIES SUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PVA-A36AA7 PUY-A36NKA7 PUY-A36NKA7-BS

More information

SUBMITTAL DATA: MSY-GL12NA & MUY-GL12NA 12,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM. System Reference:

SUBMITTAL DATA: MSY-GL12NA & MUY-GL12NA 12,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM. System Reference: M-SERIES SUBMITTAL DATA: MSY-GL12NA & MUY-GL12NA 12,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM Job Name: System Reference: Date: Indoor Unit: MSY-GL12NA Outdoor Unit: MUY-GL12NA Wireless Remote Controller

More information

SUBMITTAL DATA: MSY-GL24NA & MUY-GL24NA 24,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM. System Reference:

SUBMITTAL DATA: MSY-GL24NA & MUY-GL24NA 24,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM. System Reference: M-SERIES SUBMITTAL DATA: MSY-GL24NA & MUY-GL24NA 24,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM Job Name: System Reference: Date: Indoor Unit: MSY-GL24NA Outdoor Unit: MUY-GL24NA Wireless Remote Controller

More information

SUBMITTAL DATA: PLA-A12EA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7

SUBMITTAL DATA: PLA-A12EA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7 P-SERIES SUBMITTAL DATA: PLA-A12EA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H -CASSETTE HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PLA-A12EA7 PUZ-A12NKA7 PUZ-A12NKA7-BS INDOOR

More information

SUBMITTAL DATA: PLA-A24EA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A24NHA7

SUBMITTAL DATA: PLA-A24EA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A24NHA7 P-SERIES SUBMITTAL DATA: PLA-A24EA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H -CASSETTE HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PLA-A24EA7 PUY-A24NHA7 PUY-A24NHA7-BS INDOOR

More information

SUBMITTAL DATA: PLA-A36EA7 & PUZ-A36NKA7(-BS) 36,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A36NKA7

SUBMITTAL DATA: PLA-A36EA7 & PUZ-A36NKA7(-BS) 36,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A36NKA7 P-SERIES SUBMITTAL DATA: PLA-A36EA7 & PUZ-A36NKA7(-BS) 36,000 BTU/H -CASSETTE HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PLA-A36EA7 PUZ-A36NKA7 PUZ-A36NKA7-BS INDOOR

More information

1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5

1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5 M-SERIES SINGLE ZONE SYSTEMS MSZ-FH High Performance Wall-Mount Heat Pump Systems 1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5 3-1. SPECIFICATIONS... MSZ-FH-6 MSZ-FH09NA

More information

P-Series Full-line Catalog. Commercial-grade Applications. Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems.

P-Series Full-line Catalog. Commercial-grade Applications. Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems. P-Series Full-line Catalog Commercial-grade Applications Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems www.mitsubishipro.com 1 Take a Closer Look at the P-Series Commercial Systems

More information

P-Series Full-line Catalog. Commercial-grade Applications. Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems.

P-Series Full-line Catalog. Commercial-grade Applications. Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems. P-Series Full-line Catalog Commercial-grade Applications Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems www.mitsubishipro.com Take a Closer Look at the P-Series Commercial Systems

More information

Ductless Split Systems Concealed Duct Heat Pumps

Ductless Split Systems Concealed Duct Heat Pumps Ductless Split Systems Concealed Duct Heat Pumps PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE FRIEDRICH

More information

www.mitsubishicomfort.com Comfort is a concept many of us notice most when we re uncomfortable. And comfort is our #1 priority at Mitsubishi Cooling and Heating Solutions. Our innovative split zoned cooling

More information

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Submittal Data: Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

INVERTER-driven. Split-ductless and ducted Comfort Systems M Series Full Line Catalog.

INVERTER-driven. Split-ductless and ducted Comfort Systems M Series Full Line Catalog. INVERTER-driven Split-ductless and ducted Comfort Systems M Series Full Line Catalog www.mitsubishicomfort.com Mitsubishi Electric Cooling and Heating Solutions Mitsubishi Electric HVAC products, available

More information

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System Submittal Data: Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Compact and Quiet Design -High Efficiency DC Inverter Technology -Wireless Remote

More information

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To Submittal Data: Innovative Ductless solutions 12,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To Submittal Data: Innovative Ductless solutions 24,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8. Submittal Data: CROWN09HP230V1B Superior Performance in Extreme Temperature 9,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS 12 TECHNICAL & SERVICE MANUAL Series SEZ Model name SEZ-KD25VA(L) SEZ-KD35VA(L) SEZ-KDVA(L) SEZ-KDVA(L) SEZ-KD71VA(L) INDOOR UNIT ON/OFF TEMP TEMP.

More information

The Hyper-Heat Advantage

The Hyper-Heat Advantage The Hyper-Heat Advantage * What is? SUMMER WINTER The Mitsubishi Electric Zuba is a heat pump system, which provides excellent heating performance in the winter and effortlessly cools your home in the

More information

Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems

Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems Market District Commons Black Oak Engineering Daikin Ductless Heat Pump Split Systems N/A N/A M001 Plans Fujitsu ductless heat pump systems 353 Rte. 46 West Fairfield, NJ Fujitsu Fujitsu Halcyon 07004

More information

SEZ-KD25VAQ.TH SEZ-KD35VAQ.TH SEZ-KD50VAQ.TH SEZ-KD60VAQ.TH SEZ-KD71VAQ.TH

SEZ-KD25VAQ.TH SEZ-KD35VAQ.TH SEZ-KD50VAQ.TH SEZ-KD60VAQ.TH SEZ-KD71VAQ.TH SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL December No.HWE0 REVISED EDITION-B Indoor unit [Model names] SEZ-KD25VAQ SEZ-KD35VAQ SEZ-KDVAQ SEZ-KDVAQ SEZ-KD71VAQ [Service Ref.] SEZ-KD25VAQ.TH

More information

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI 24,000 BTUH 24,000 Ceiling BTU/H Cassette Ceiling Heat Casse3e Pump Heat System Pump System Job Name Location Date Purchaser

More information

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP www.mitsubishielectric.ca P-SERIES The Attraction of Being Untraditional Mr. Slim P-Series is the ductless solution for demanding environments that

More information

P-Series Full-line Catalog. Commercial-grade Applications. Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems.

P-Series Full-line Catalog. Commercial-grade Applications. Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems. P-Series Full-line Catalog Commercial-grade Applications Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems www.mitsubishipro.com Take a Closer Look at the P-Series Commercial Systems

More information

Samsung 360 Cassette, Single Zone, Split System

Samsung 360 Cassette, Single Zone, Split System Job Name Purchaser Submitted to Unit Designation Location Engineer Reference Schedule # Approval Page 1 of 5 Construction Specifications Model Indoor Unit Model Number Outdoor Unit Model Number Nominal

More information

Ductless Split Systems Wall-mounted, Multizone Heat Pump

Ductless Split Systems Wall-mounted, Multizone Heat Pump Ductless Split Systems Wall-mounted, Multizone Heat Pump PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE

More information

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56 Product Data INDUSTRY LEADING FEATURES / BENEFITS AN INEXPENSIVE AND

More information

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Internal Condensate

More information

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP www.mitsubishielectric.ca P-SERIES The Attraction of Being Untraditional Mr. Slim P-Series is the ductless solution for demanding environments that

More information

External Dimensions MSZ-FH25VE MSZ-FH35VE MSZ-FH50VE INDOOR UNIT INDOOR UNIT MSZ-GF60VE MSZ-GF71VE MSZ-SF25VE MSZ-SF35VE MSZ-SF42VE MSZ-SF50VE

External Dimensions MSZ-FH25VE MSZ-FH35VE MSZ-FH50VE INDOOR UNIT INDOOR UNIT MSZ-GF60VE MSZ-GF71VE MSZ-SF25VE MSZ-SF35VE MSZ-SF42VE MSZ-SF50VE External Dimensions MSZ-EF8VE(W)(B)(S) MSZ-EFVE(W)(B)(S) MSZ-EFVE(W)(B)(S) MSZ-EF3VE(W)(B)(S) MSZ-EF4VE(W)(B)(S) MSZ-EF0VE(W)(B)(S) MSZ-FHVE MSZ-FH3VE MSZ-FH0VE 88 9 87 7 or more ir in Installation plate

More information

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

Ductless Split Systems Wall-mounted, Single Zone Heat Pump Ductless Split Systems Wall-mounted, Single Zone Heat Pump PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H

More information

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -Medium Static Pressure Capability -Return

More information

M-SERIES PRODUCT CATALOG

M-SERIES PRODUCT CATALOG M-SERIES PRODUCT CATALOG Zoned Comfort Solutions www.mitsubishicomfort.com MAKE COMFORT PERSONAL Make Comfort Personal. It s not just a tag line or a marketing slogan. It s what we do every day. No other

More information

DUCTLESS FULL LINE CATALOG

DUCTLESS FULL LINE CATALOG DUCTLESS FULL LINE CATALOG Spring 2016 Edition 1 Versatile Ductless Systems can increase your sales opportunities Bryant offers a complete line of ductless HVAC systems designed to make any space more

More information

Ductless Split Systems Ceiling Cassette Heat Pumps

Ductless Split Systems Ceiling Cassette Heat Pumps Ductless Split Systems Ceiling Cassette Heat Pumps PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE

More information

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100 Ceiling cassette (-way flow type) RA Data G8 -P-VBM-E. SPECIFICATIONS - 98. EXTERNAL DIMENSIONS - 99 3. CENTER OF GRAVITY -. ELECTRICAL WIRING DIAGRAMS -. SOUND LEVELS -. Sound levels -. NC curve 6. TEMPERATURE/AIRFLOW

More information

FBQ. DC Duct Heat Pump or Cooling Only

FBQ. DC Duct Heat Pump or Cooling Only FBQ DC Duct Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FBQ DC Duct systems offer a powerful solution, compact in design and easily concealed in a ceiling. With both cooling only and heat

More information

Product Catalogue. Mitsubishi Electric Sales Canada Inc. Pseries.MrSlim.ca

Product Catalogue. Mitsubishi Electric Sales Canada Inc. Pseries.MrSlim.ca Product Catalogue Environmental Vision 2021 Environmental Vision 2021 is the long-term environmental management vision of the Mitsubishi Electric Group. With the guideline of making positive contributions

More information

DAIKIN FBQ DUCTED SERIES HEATING & COOLING SYSTEMS. DC DUCT-CONCEALED Up to 17.5 SEER / Up to 10.6 HSPF Up to 13.0 EER

DAIKIN FBQ DUCTED SERIES HEATING & COOLING SYSTEMS. DC DUCT-CONCEALED Up to 17.5 SEER / Up to 10.6 HSPF Up to 13.0 EER DAIKIN FBQ DUCTED SERIES HEATING & COOLING SYSTEMS DC DUCT-CONCEALED Up to 17.5 SEER / Up to 10.6 HSPF Up to 13.0 EER FBQ SERIES HEATING AND COOLING SYSTEMS DC DUCT CONCEALED Indoor Unit FBQ18PVJU FBQ24PVJU

More information

Residential and Light Commercial Ductless Systems Catalog

Residential and Light Commercial Ductless Systems Catalog Residential and Light Commercial Ductless Systems Catalog May 2018 Table of Contents Midea Global 3 Ductless Benefits 5 Single and Multi-Zone Solutions 9 Single Zone Residential 13 Max Series 15 Advantage

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CDITIERS TECHNICAL & SERVICE MANUAL No. OCH468 REVISED EDITI-A HFC utilized R4A June 2 [Model name] MXZ-8B48NA PAC-AKA5BC PAC-AKA3BC (Indispensable

More information

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems Ductless Split Systems J Series The Next Generation of Ductless Split Systems Advanced technology delivering quiet, energy efficient comfort solutions THE EXPERTS IN ROOM AIR CONDITIONING The Next Generation

More information

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems Ductless Split Systems J Series The Next Generation of Ductless Split Systems Advanced technology delivering quiet, energy efficient comfort solutions THE EXPERTS IN ROOM AIR CONDITIONING The Next Generation

More information

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: T2HA, T3HA, and T4HA with CAHB Systems Limited Range Multi-Zone Heat Pumps Rev. 1.1 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: ERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED

More information

Lennox Mini-Split Systems Year-Round Comfort and Performance

Lennox Mini-Split Systems Year-Round Comfort and Performance Lennox Mini-Split Systems Year-Round Comfort and Performance Single- and Multi-Zone Heat Pump Systems UP TO 24.0 SEER AND 11.0 HSPF The solution that works where others won t. LENNOX MINI-SPLIT AT A GLANCE:

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR ASU9RL2 ASU12RL2 OUTDOOR AOU9RL2 AOU12RL2 1.INDOOR UNIT : ASU9RL2 ASU12RL2 DTR_AS072E_01 2012.11.02 1. INDOOR UNIT CONTENTS 1. FEATURE...

More information

L E N N O X MINI-SPLIT SYSTEMS THE SOLUTION THAT WORKS WHERE OTHERS WON T.

L E N N O X MINI-SPLIT SYSTEMS THE SOLUTION THAT WORKS WHERE OTHERS WON T. L E N N O X MINI-SPLIT THE SOLUTION THAT WORKS WHERE OTHERS WON T. LENNOX MINI-SPLIT OFFER YEAR-ROUND COMFORT AND PERFORMANCE. Energy-efficient operation and easy installation make Lennox Mini-Split Systems

More information

Units without Remote Controller Units without Remote Controller Panel Units with Wireless Remote Controller

Units without Remote Controller Units without Remote Controller Panel Units with Wireless Remote Controller 47 SERIES SELECTION Series line-up consists of two types of indoor units. Choose the model that best matches room conditions. STEP 1 SELECT INDOOR UNIT Select the optimal unit and capacity required to

More information

Kühl J Series DUCTLESS ROOM AIR CONDITIONERS THE EXPERTS IN ROOM AIR CONDITIONING. Wall-mounted Ceiling Cassette The Insider Concealed Ducted

Kühl J Series DUCTLESS ROOM AIR CONDITIONERS THE EXPERTS IN ROOM AIR CONDITIONING. Wall-mounted Ceiling Cassette The Insider Concealed Ducted Kühl J Series DUCTLESS ROOM AIR CONDITIONERS SPLIT SYSTEMS Wall-mounted Ceiling Cassette The Insider Concealed Ducted THE EXPERTS IN ROOM AIR CONDITIONING THE NEXT GENERATION OF DUCTLESS SPLIT SYSTEMS

More information

Well rounded. 360 CASSETTE. A truly circular cassette. Enjoy even airflow from a beautifully sleek design that fits into any setting.

Well rounded. 360 CASSETTE. A truly circular cassette. Enjoy even airflow from a beautifully sleek design that fits into any setting. 360 CASSETTE Well rounded. A truly circular cassette. Enjoy even airflow from a beautifully sleek design that fits into any setting. Product Registration Required Conditions Apply 2017 Samsung HVAC 63714_SAMSUN_360_Cassette_v13.indd

More information

SINGLE Technical Data Book SINGLE Duct S for America (R410A, HP)

SINGLE Technical Data Book SINGLE Duct S for America (R410A, HP) SINGLE Technical Data Book SINGLE Duct S for America (R41A, HP) Model : AC MNHDCH/AA (Indoor unit) AC JXADCH/AA (Outdoor unit) History Version Modification Date Remark Ver.1. Release SINGLE Duct S for

More information

InverterFlex SerIeS InverterFlex Systems condition up to five rooms

InverterFlex SerIeS InverterFlex Systems condition up to five rooms InverterFlex SerIeS InverterFlex Systems condition up to five rooms Floor & Ceiling Console Outdoor Unit Wireless remote included with each indoor unit Ducted Unit Multi-Zone Heat Pumps 18,000 to 42,000

More information

Air Conditioner SVC MANUAL(Exploded View)

Air Conditioner SVC MANUAL(Exploded View) Internal Use Only http://biz.lgservice.com Air Conditioner SVC MANUAL(Exploded View) Type : Ceiling Concealed Duct MODEL : AMNW24GBGA0 [LMHN240HV] AMNW36GBGA0 [LMHN360HV] CAUTION Before Servicing the unit,

More information

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH Revision D: Capacity corrections have been corrected [7-1. 2), 3)]. OBH684 REVISED EDITION-C is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH684 REVISED EDITION-D Models MUZ-FH06NA MUZ-FH09NA

More information

SERVICE MANUAL. Commercial Air Conditioning. MULTI upgrade series

SERVICE MANUAL. Commercial Air Conditioning. MULTI upgrade series Coercial Air Conditioning SERVICE MANUAL MULTI upgrade series Models Indoor: AB09CS1ERA AB12CS1ERA AB18CS1ERA AB24ES1ERA AC12CS1ERA AC18CS1ERA AC24CS1ERA AD09LS1ERA AD12LS1ERA AD18LS1ERA AD24LS1ERA Outdoor:

More information

InverterFlex SERIES InverterFlex Systems condition up to five rooms

InverterFlex SERIES InverterFlex Systems condition up to five rooms InverterFlex SERIES InverterFlex Systems condition up to five rooms Floor & Ceiling Console Outdoor Unit Rated up to 22 SEER Wireless remote included with each indoor unit Ducted Unit Multi-Zone Heat Pumps

More information

LV Series. SEER 15+ Concealed Built in Heat Pump

LV Series. SEER 15+ Concealed Built in Heat Pump LV Series SEER 15+ Concealed Built in Heat Pump EXPERTISE AND INNOVATION Daikin s slim duct systems offer a built in solution with the benefits of duct free technology. Installed similar to a traditional

More information

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A Revision B: MUZ-GL09NA- U8 and MUZ-GL09NAH- U8 have been added. Please void OBH733 REVISED EDITION-A. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH733 REVISED EDITION-B Models MUZ-GL09NA

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL XH7R / CH7R, C7R XH7R / CH7R, C7R XH7R / CH7R, C7R TH7R / CH7R, C7R TH7R / CH7R, C7R TH7R / CH7R, C7R THH7R / CH7R THH7R / CH7R FILE NO. KH7R / CH7R, C7R KH07R / CH07R,

More information

Just feel well. 2017/2018 Air conditioning

Just feel well. 2017/2018 Air conditioning 1947-20 17 2017/2018 Air conditioning Unique solutions 40 Unique and advanced design for vertical or horizontal installation VERTICAL INSTALLATION q Vertical installation with compact dimensions, only

More information

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC Revision A: MUZ-HM09/12NA- U8, MUZ-HM09/12NA2- U8, MUZ-HM15/18NA- U1, MUZ-HM15/18NA2- U1 and MUZ-HM24NA2- U1 have been added. Please void OBH747. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A.

More information

Air Conditioner CONTENTS

Air Conditioner CONTENTS ORDER NO. MAC0509068C2 Air Conditioner CS-F24DD1E5 CU-B24DBE5 CS-F28DD1E5 CU-B28DBE5 CS-F28DD1E5 CU-B28DBE8 CS-F34DD1E5 CU-B34DBE5 CS-F34DD1E5 CU-B34DBE8 CS-F43DD1E5 CU-B43DBE8 CS-F50DD1E5 CU-B50DBE8 CONTENTS

More information

Why Choose Mitsubishi Electric?

Why Choose Mitsubishi Electric? Multi Split Systems Why Choose Mitsubishi Electric? Whether it's consistent cooling and heating for the home or office, Mitsubishi Electric offers you state-of-the art technology that is quiet, simple

More information

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air technical data FDKS-CVMB Concealed ceiling, Inverter Controlled Unit air conditioning systems Split Sky Air Indoor Units R410A FDKS-CVMB TABLE OF CONTENTS FDKS-CVMB 1 Features.............................................................

More information

Revision C: Specification has been corrected. The value of "Moisture removal" for MSZ-GE24NA and MSY-GE24NA has been corrected. [2.7 pt.

Revision C: Specification has been corrected. The value of Moisture removal for MSZ-GE24NA and MSY-GE24NA has been corrected. [2.7 pt. Use the speciþed refrigerant only Never use any refrigerant other than that specified. Doing so may cause a burst, an explosion, or fire when the unit is being used, serviced, or disposed of. Correct refrigerant

More information

A single answer for multiple zones.

A single answer for multiple zones. FJM - Free Joint Multi A single answer for multiple zones. More comfort with less. This powerful unit supports up to five indoor units for multi-zone control with one outdoor unit. It s also available

More information

ELECTRICAL QUANTITY WEIGHT (LB)

ELECTRICAL QUANTITY WEIGHT (LB) VRF SYSTEM INDOOR UNIT ENTERING AIR TEMPERATURES ( F) CAPACITIES (kbtuh) Max SOUND ELECTRICAL WEIGHT TOSHIBA-CARRIER COOLING HEATING Airflow PRESSURE, MARK NO. TYPE ROOM TOTAL SENSIBLE HEATING V / Ø /

More information

A single answer for multiple zones.

A single answer for multiple zones. Free Joint Multi (FJM) A single answer for multiple zones. More comfort with less. This powerful unit supports two to five indoor units for multi-zone control with one outdoor unit. It s also available

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL KS1872 + C1872 + CL1872 KS2472 + C2472 + CL2472 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KS1872 KS2472 Product

More information

Air Conditioning. Product Information. Standard Inverter Outdoor Unit PUHZ-P100VHA4/YHA2

Air Conditioning. Product Information. Standard Inverter Outdoor Unit PUHZ-P100VHA4/YHA2 PUHZ-P100VHA4/YHA2 offices or shops where two units are required. These can be Mr Slim ceiling cassettes (PLA-RP & SLZ-KA), ceiling suspended (PCA-RP), ducted (PEAD-RP) or wall mounted (PKA-RP) models

More information

Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center

Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center Mechanical Contractor Company: Contact: Phone: Address:, Distributor Branch

More information

AIR COOLED PACKAGED AIR CONDITIONERS

AIR COOLED PACKAGED AIR CONDITIONERS PLXPMT1726 AIR COOLED PACKAGED AIR CONDITIONERS COOLING ONLY 50Hz Suitable for factories DIRECT AIR BLOW TYPE DUCT CONNECTION TYPE HFC R410A Line Up for Factories and Offices We have entered an era in

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to

More information

ZONED COMFORT SOLUTIONS

ZONED COMFORT SOLUTIONS M-SERIESCATALOG ZONED COMFORT SOLUTIONS M-SERIES CATALOG I 05.2018 I WWW.MITSUBISHICOMFORT.COM MAKE COMFORT PERSONAL Make Comfort Personal. It s not just a tagline or a marketing slogan. It s what we do

More information

TECHNICAL & SERVICE MANUAL. Ceiling Concealed

TECHNICAL & SERVICE MANUAL. Ceiling Concealed STAND BY DEFROST CHECK CLOCK ON OFF NOT AVAILABLE FILTER CHECK MODE TEST RUN FUNCTION SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL Series SEZ Ceiling Concealed R40A.OC0 REVISED EDITION-A

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT:. TRIAL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. 38.7107.102. 0.8180.611.02 09/2012 IMPORTANT! Please read before installation This air conditioning

More information

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18 Submittal Sheet Submitted for: Approval Record Job Name: Contractor: Engineer: Date: Location: Tag: AIR-CON MULTI-SPLIT II Indoor Units Outdoor Unit High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 19,100 BTU/h,200 BTU/h 30,600 BTU/h Outdoor Model No. CU-3KE19NBU CU-4KE24NBU

More information

DUCTLESS SPLIT SYSTEMS

DUCTLESS SPLIT SYSTEMS DUCTLESS SPLIT SYSTEMS SINGLE and MULTI-ZONE WALL MOUNTED, FLOOR/CEILING UNIVERSAL, CEILING CASSETTE and CEILING SUSPENDED. DUCTLESS SPLIT SYSTEMS The ultimate room air conditioner. Easy to install. Exceptionally

More information

MINI-SPLIT STANDARD CONDITIONERS SINGLE ZONE. Available styles

MINI-SPLIT STANDARD CONDITIONERS SINGLE ZONE. Available styles MINI-SPLIT STANDARD AIR CONDITIONERS SINGLE ZONE Mini-Split Standard systems utilize the same duct-free technology as Art Cool units in a streamlined, low profile design. Models are available in a variety

More information

FTQ. Daikin Inverter Ducted Heat Pump

FTQ. Daikin Inverter Ducted Heat Pump FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative

More information

Concealed ceiling unit with medium ESP

Concealed ceiling unit with medium ESP FXSQ-A Concealed ceiling unit with medium ESP Slimmest yet most powerful medium static pressure unit on the market Slimmest unit in class, only 245mm (3mm built-in height) and therefore narrow ceiling

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CLM97 CLM7 CLM7 FILE NO. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 9,700 BTU/h,00 BTU/h 0,600 BTU/h Outdoor Model No.

More information

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value. Midea Ducted and Cassette Split Systems Maximum versatility, maximum value. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.

More information

Geniuses at work. Residential Mini Splits

Geniuses at work. Residential Mini Splits Residential Mini Splits Smart Pearl Smart Whisper Geniuses at work. Two smart ways to heat and cool your home. Be the smartest person in the room when you get your home equipped with a Wi-Fi enabled heat

More information

Technical Manual. R410A 50Hz Universal Outdoor Series Inverter type. R410A50Hz Universal Outdoor Series Technical Manual LCAC/2016.

Technical Manual. R410A 50Hz Universal Outdoor Series Inverter type. R410A50Hz Universal Outdoor Series Technical Manual LCAC/2016. Outdoor Unit R410A 50Hz Universal Outdoor Series Inverter type Technical Manual LCAC/2016.1 I GD Chigo Heating & Ventilation Equipment Co., Ltd. Content Part 1. General Information... 1 1. Nomenclature...

More information

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air technical data FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit air conditioning systems Split Sky Air Indoor Units R410A FDXS-CVMB TABLE OF CONTENTS FDXS-CVMB 1 Features.............................................................

More information