Common Venting For Rheem Commercial Tankless Natural Gas Water Heaters
|
|
- Clarissa Evans
- 5 years ago
- Views:
Transcription
1 Water Commercial Gas Common Venting Tankless Water Heaters Common Venting For Rheem Commercial Tankless Natural Gas Water Heaters Overview Rheem offers a manufacturer tested and UL/ULC listed common venting system providing longer lengths and fewer wall penetrations than single-unit venting. The system is polypropylene stabilized (PPs) material and Intertek certified for UL - and ULC-S and manufactured by CentroTherm EcoSystems in the USA. Venting pieces are self-locking and sealing and can be pushed together without the use of cement or glue. The common vent system is CSA certified (ANI Z.0., Gas Water Heaters Standards) for use with up to 0 units of the following Rheem high efficiency, natural gas tankless water heaters; RTGH-C9DVLN and RTGH-CM9DVLN. All common venting configurations tested to,00 ft. Common Vent System Characteristics PROPERTY: STANDARD: RESULTS: Materials & Construction Low Temperature Handling UL- Pass at - F (-0 C) U.V. Stability ASTM G- Pass Water Absorption UL-.% Common Vent Diameter CE EN- " (0mm) " (00mm) 0" (0mm) 0" (0mm) " (00mm) CE EN- Min. Thickness:.0" (.mm) Max. Thickness:.99" (.0mm) Thickness " (0mm) CE EN- Min. Thickness:.0" (.mm) Max. Thickness:." (.mm) Deflection Temperature Under Load ASTM D- 0 F (0 C) Flammability UL-9 V-0 Performance Max. Flue Gas Temperature UL- & ULC-S CE EN- 0 F (0 C) F (0 C) Clearance to Combustibles UL- & ULC-S 0" (0mm) at 0 F (0 C) Leakage UL- Pass Pressure UL-. kpa Pull UL- & ULC-S Min. 0 lb. force (.kn) Flame Spread & Smoke UL-, ULC-S0 & ASTM E- </<0 w/ces recommended wrap Fire Rating UL-9, ULC-S & ASTM E- hr Fire Rating w/ces recommended passive fire protection system Maximum Vent Length (air intake and exhaust) each: OF WATER HEATERS " COMMON " COMMON 0" COMMON 0' ( m) 00' (0 m) 00' (0 m) 0' ( m) 00' (0 m) 00' (0 m) 0' ( m) 00' (0 m) 00' (0 m) N/A 00' (0 m) 00' (0 m) N/A ' ( m) 00' (0 m) N/A ' ( m) 00' (0 m) N/A ' ( m) 00' (0 m) 9 N/A N/A 00' (0 m) 0 N/A N/A ' ( m) Equivalent Vent Length: " COMMON " COMMON 0" COMMON Degree Elbow.0' (. m).0' (. m).0' (. m) Degree Elbow.0' (. m).' (0. m).' (0. m) NOTES: Tee Termination has same equivalent vent length as Degree Elbow. The system may be vented horizontally through a wall or vertically through the roof. Header kits have already been counted and do not need to be added. Systems with 9-0 heaters can be vented in-line only. INTEGRATED HOME COMFORT PRINTED IN U.S.A. 0/ WP FORM NO. TK-0RH Rev.
2 BACK TO BACK COMMON ING The following back to back header vent kits can be purchased separately to create Back to Back Common Venting system: Back to Back venting requires additional gas chip, sold separately. Consult Rheem Applications Engineer before purchase. Direct Vent Header Kits - ( cm cm) Min (9cm) Max 0 (.m) Room Air Intake Header Kits - ( cm cm) Max. vent length distance (header kits not counted towards max vent length) 0. ( cm) Degree upward Diagrams illustrate horizontal intake and exhaust, vertical intake and exhaust also available, but not pictured. Max. vent length distance (header kits not counted towards max vent length) 0. ( cm) Degree upward PART SP09A PART SP09A SP09B " SP09C SP09A SP09B SP09C SP09D " SP09E SP09F SP09G SP09A SP09B " SP09C SP09A SP09B SP09C SP09D " SP09E SP09F SP09G SP09A SP09B SP09C SP09D 0" SP09E SP09F SP09G SP09B SP09C SP09D 0" SP09E SP09F SP09G These kits contain only minimum required vent parts to create a common venting trunk line and a connection from the trunk line to water heaters. Vent parts included in these kits DO NOT count for equivalent vent length except a degree elbow for the air intake included in a room air kit. Additional vent parts will be required to complete the common venting system. Refer to Parts List of this installation instructions for additional information.
3 SCALE.000 INLINE COMMON ING The following inline header vent kits can be purchased separately to create Inline Common Venting system: Direct Vent Header Kits - ( cm cm) Min (9cm) Max 0 (.m) Max. vent length distance (header kits not counted towards max vent length) 0. ( cm) Degree upward Diagrams illustrate horizontal intake and exhaust, vertical intake and exhaust also available, but not pictured. PART SP090A SP090B " SP090C SP090A SP090B SP090C SP090D " SP090E SP090F SP090G SP090A SP090B SP090C SP090D SP090E 0" SP090F SP090G SP090H 9 SP090J 0 Room Air Intake Header Kits - ( cm cm) Max. vent length distance (header kits not counted towards max vent length) 0. ( cm) Degree upward These kits contain only minimum required vent parts to create a common venting trunk line and a connection from the trunk line to water heaters. Vent parts included in these kits DO NOT count for equivalent vent length except a degree elbow for the air intake included in a room air kit. Additional vent parts will be required to complete the common venting system. Refer to Parts List of this installation instructions for additional information. PART SP090A SP090B " SP090C SP0909A SP0909B SP0909C SP0909D " SP0909E SP0909F SP0909G SP09A SP09B SP09C SP09D SP09E 0" SP09F SP09G SP09H 9 SP09J 0
4 INLINE COMMON ING Inline Common Vent Kit Components Exhaust Parts & in Direct Vent Header Kits only for and for 0 for and for 0 Air Intake, 0 Included in Direct Vent Kits Only Included in 0 Direct Vent Kit Only, 0 Included in Direct Vent Kits Only Included in 0 Direct Vent Kit Only Included in Room Air Kits Only Included in Room Air Kits Only PART PART DESCRIPTION SP09A " PVC to PP Adaptor SP09J ", Elbow SP09AD SP09L SP09AH SP09K SP09AK " Air Intake Branch Tee " Air Intake Branch Tee " Tee Cap " Tee Cap 0" Tee Cap SP09D Non-Return Valve (NRV) " Straight Pipe, ' SP09G (Direct Vent) " Straight Pipe, ' SP09Z (Room Air) NOTE: All header kit parts available individually for replacement order using part numbers above. NOTE: For " and " trunk diameters, exhaust branches are ", intake branches are " diameter, for 0" diameter trunk, both exhaust and intake branches are " diameter. PART SP09AC SP09E SP09AE SP09AG SP09F SP09AJ PART DESCRIPTION " Exhaust Branch Tee " Exhaust Branch Tee 0" Exhaust and Air Intake Branch Tee " Horizontal Drain Fitting " Horizontal Drain Fitting 0" Horizontal Drain Fitting 9 SP09C Universal Ball Valve Siphon 0 SP09B ", Degree Elbow SP09Y " Connector Ring SP09AL " to " Increaser SP09AB " Bird Screen SP09X " Connector Ring SP09H Centrocerin Lubricant
5 BACK TO BACK COMMON ING Back to Back Common Vent Kit Components PART PART DESCRIPTION SP09A " PVC to PP Adaptor SP09AH " Tee Cap SP09K " Tee Cap SP09AK SP09D 0" Tee Cap Non-Return Valve (NRV) SP09G " Straight Pipe, ' Exhaust SP09AG SP09F " Horizontal Drain Fitting " Horizontal Drain Fitting SP09AJ SP09C 0" Horizontal Drain Fitting Universal Ball Valve Siphon SP09Y " Connector Ring SP09AM SP09AP " Back to Back Exhaust Branch Tee " Back to Back Exhaust Branch Tee SP09AS 0" Back to Back Exhaust Branch Tee 9 9 SP09AN SP09AR " Back to Back Air Intake Branch Tee " Back to Back Air Intake Branch Tee Air Intake SP09AT 0" Back to Back Air Intake Branch Tee 0 SP09AU " Tee Cap 0 Parts, 9 & 0 in Direct Vent Header Kits only SP09AV " Tee Cap SP09BC ", Degree Elbow SP09BD ", Degree Elbow SP09AB " Bird Screen SP09X " Connector Ring SP09H Centrocerin Lubricant NOTE: All header kit parts available individually for replacement order using part numbers above. NOTE: Exhaust branches are ", intake branches are " diameter.
6 Water Commercial Gas Common Venting Tankless Water Heaters For Rheem Commercial Tankless Natural Gas Water Heaters Vent Run Accessories 9 0 IMAGE PART DESCRIPTION " " 0" Air Intake Branch Tee SP09AD SP09L SP09AE Degree Elbow SP09BE SP09M SP09BM Degree Elbow SP09BF SP09N SP09BN Straight Pipe, ' SP09BG SP09P SP09BP Straight Pipe, ' SP09BH SP09R SP09BR Straight Pipe, ' SP09BJ SP09S SP09BS Straight Pipe, ' SP09BK SP09T SP09BT 90 Degree Elbow Vertical Support SP09BL SP09U SP09BU 9 Bird Screen SS SP09AY SP09V SP09AZ 0 Tee Termination SP09BA SP09W SP09BB Support Clamp SP09AW SP09AA SP09AX Centrocerin Lubricant SP09H SP09H SP09H CENTROTHERM PPS PVC CPVC Chemical Resistance Aromatic Hydrocarbons ü X X Sulfuric Acid ü X X Hydrochloric Acid ü X X UL Listed (0 F to 0 F) Listed Not Listed Not Listed Actual Working Temperature F (0 C ) F (0 C) 0 F ( C ) 9 F ( C) 0 F ( C ) 9 F (90 C) Softening Temperatures 0 F (0 C) F (0 C) 00 F (9 C) Environmentally Friendly Production ü X X No Chloride Leaching ü X X Fully Recyclable ü X X NOTE: Temperature values in table represent exhaust flue temperatures. For approximate max. water set point temperatures, subtract 0 degrees F. Specifications The Common Vent System shall be manufactured from polypropylene stabilized (PPs). The Common Vent System shall be UL- & ULC-S rated for use with maximum flue gas temperatures of 0 F (0 C), and be rated to a maximum vent pressure of 0" of water column. Multiple Unit Controls RTGH-CM9DVLN includes manifold control, and does not require other multiple unit controls. RTGH-C9DVLN requires one of the following optional Multiple Unit controls to manifold two or more water heaters together. Without the Multiple Unit Control, water heaters operate independently MULTIPLE UNIT CONTROLS RTGH-C9DVLN RTGH-CM9DVLN MAXIMUM NO. OF WATER HEATERS EZ Link Optional Not Required MIC- Optional Not Required MIC- Optional Not Required MIC- with MICS-0 Optional Not Required 0* Manifold Control N/A Included 0* *Maximum number of water heaters per one common vent system is 0, depending on trunk diameter In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Water Heating Northmeadow Parkway, Suite 00 Roswell, Georgia 00 Rheem Canada Ltd./Ltée Edgeware Road, Unit Brampton, Ontario LY 0P INTEGRATED HOME COMFORT PRINTED IN U.S.A. 0/ WP FORM NO. TK-0RH Rev.
PRODUCT GUIDE Commercial Condensing Tankless Water Heaters COMMERCIAL TANKLESS SOLUTIONS. Ruud.com/commercial-tankless
PRODUCT GUIDE Commercial Condensing Tankless Water Heaters COMMERCIAL TANKLESS SOLUTIONS Ruud.com/commercial-tankless WHY RUUD COMMERCIAL TANKLESS? DELIVERING ENERGY SAVINGS, FLEXIBILITY & SUPPORT Introducing
More informationRHEEM TANKLESS GAS WATER HEATERS
PRODUCT GUIDE Tankless Gas Water Heaters WELCOME TO CONTINUOUS HOT WATER RHEEM TANKLESS GAS WATER HEATERS OFFER ENERGY-EFFICIENT HOT WATER FOR YOUR CUSTOMER S HOME OR BUSINESS PRODUCT GUIDE TANKLESS GAS
More informationHOT WATER CONTINUOUS YOU CAN RELY ON RUUD TANKLESS GAS WATER HEATERS OFFER ENERGY-EFFICIENT HOT WATER FOR YOUR CUSTOMER S HOME OR BUSINESS
PRODUCT BROCHURE Tankless Gas Water Heaters CONTINUOUS HOT WATER YOU CAN RELY ON CONDENSING MODEL WITH BUILT-IN RECIRCULATION COMING SOON! RUUD TANKLESS GAS WATER HEATERS OFFER ENERGY-EFFICIENT HOT WATER
More informationWELCOME TO CONTINUOUS HOT WATER RHEEM COMMERCIAL CONDENSING TANKLESS GAS WATER HEATERS OFFER ENERGY-EFFICIENT HOT WATER FOR YOUR CUSTOMER S BUSINESS
PRODUCT GUIDE Commercial Condensing Tankless Water Heaters WELCOME TO CONTINUOUS HOT WATER RHEEM COMMERCIAL CONDENSING TANKLESS GAS WATER HEATERS OFFER ENERGY-EFFICIENT HOT WATER FOR YOUR CUSTOMER S BUSINESS
More informationRheem Commercial Tankless System Free Standing
Commercial Gas Water INTEGRATED HOME CO M F O RT Tankless Water Heater Systems Rheem Commercial Tankless System Free Standing This custom-built tankless solution arrives on the jobsite factory-assembled
More informationRheem Commercial Tankless System Wall Hung
Commercial Gas Water INTEGRATED HOME CO M F O RT Tankless Water Heater Systems Rheem Commercial Tankless System Wall Hung This custom-built tankless solution arrives on the jobsite factory-assembled with
More informationCOMMON VENTING SYSTEM SUBMITTAL SHEET
COMMON VENTING SYSTEM SUBMITTAL SHEET Job Name: Location: Architect/Engineer: Wholesaler: Model No.: Notes: Total Vent Length: Total System Btu/h: FEATURES AND BENEFITS The Common Vent System provides
More informationThe intelligent alternative for flue gas venting systems
The intelligent alternative for flue gas venting systems FIRST LISTED InnoFlue is the first polymeric vent system tested and listed to ULC-S636 and UL-1738 in North America Intelligent for a good reason
More informationCOMMON VENT SYSTEM. Features and Benefits. Model Applicability
Features and Benefits COMMON VENT SYSTEM The CVent Common Venting system provides longer vent lengths and fewer wall or roof penetrations than conventional single-unit venting. For the exhaust flue, CVent
More informationINSTALLATION OF CENTROTHERM INNOFLUE SINGLE WALL POLYPROPYLENE VENTING SYSTEMS
SUPPLEMENT VENTING INSTRUCTIONS FOR INSTALLATION AND OPERATING INSTRUCTION MANUALS 238 48384 00, 238 44727 00, 238 44445 00, 238 48144 00, 238 47936 00, 238 45917 00, 238 45637 00, 238 47448 00, 238 48071
More informationINSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT
C US This manual must be left with owner and should be hung on or adjacent to the boilerfor reference. COMMON VENTING MODELS CHS-300 through CHS-399 INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS
More informationHydronic Air Handler Powered by Tankless Technology
Integrated Solutions Hydronic Air Handler Powered by Tankless Technology RW1P/RW1T- Series Nominal Heating Capacities: 40-100 kbtu [11.7-29.3 kw] Tankless Water Heater Models: RTG-64DVL indoor direct vent
More informationRHEEM TANKLESS GAS WATER HEATERS
PRODUCT GUIDE Tankless Gas Heaters WELCOME TO CONTINUOUS HOT WATER RHEEM TANKLESS GAS WATER HEATERS OFFER ENERGY-EFFICIENT HOT WATER FOR YOUR CUSTOMER S HOME OR BUSINESS PRODUCT GUIDE TANKLESS GAS WATER
More informationPVC, CPVC, PP & SS Vent Supplement
PVC, CPVC, PP & SS Vent Supplement L I S T E D This document is intended to be used by a qualified heating contractor or service technician. Read all instructions within this document and within the PRESTIGE
More informationZ-DENS Z-FLEX. Polypropylene Vent Systems for High Efficiency Condensing Appliances. Single Wall Rigid Flexible Liner Concentric
Z-FLEX Advanced Venting Solutions Z-DENS Polypropylene Vent Systems for High Efficiency Condensing Appliances Single Wall Rigid Flexible Liner Concentric Z-Flex Joins Forces with Cox Geelen Z-Flex North
More informationPVC COMMON VENT SYSTEM. [Applicable Model] Model: PP4XPVC4-ADAPT(4"PP to 4" PVC Adapter)
Installation Manual PVC COMMON VENT SYSTEM [Applicable Model] Model: PP4XPVC4-ADAPT(4"PP to 4" PVC Adapter) NORITZ AMERICA CORPORATION EZ98DV (GQ-C2859WX-FF US) EZDV (GQ-C3259WX-FF US) NCC99CDV (GQ-C3259WZ-FF
More informationINSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS
SUPPLEMENT VENTING INSTRUCTIONS FOR INSTALLATION AND OPERATION INSTRUCTION MANUALS FOR THE FOLLOWING PRODUCT TYPES: HIGH EFFICIENCY CONDENSING COMMERCIAL, COMMERCIAL POWER DIRECT VENT, LIGHT DUTY COMMERCIAL
More informationManual Addendum. This Addendum needs to be used in conjunction with the Evergreen Boiler Manual P/N _0518
Manual Addendum This Addendum needs to be used in conjunction with the Evergreen Boiler Manual P/N 550-100-191_0518 ATTENTION to installers and homeowners of Evergreen boilers. KEEP THIS ADDENDUM WITH
More informationSENSEI Series Features
SENSEI Series Features Designed for North American Needs Combines Rinnai Global Technologies and Best Practices Same Rinnai Quality and Reliability Focused on 3 ideals to Captivate Customers: 1. Installation
More informationHydronic Air Handler Powered by Tankless Technology
Integrated Solutions Hydronic Air Handler Powered by Tankless Technology RHWB- Series Nominal Heating Capacities: 32-90 kbtu [9.38-26.39 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in
More informationGWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions
GWS Gas-Fired Water Boilers Venting Manual Hazard definitions Contents Page Hazards that will cause severe personal injury, death or substantial property damage. Hazards that can cause severe personal
More informationVENTING APPLICATION GUIDE
VENTING APPLICATION GUIDE Natural Gas or Propane Modulating & Condensing Boilers and Water Heaters This document applies to the following models: Boilers AM 399B AM 500B AM 750B AM 1000B Gas-Fired Boilers
More informationProduct Brochure Water Heaters Tankless Gas WELC ME TO CONTINUOUS HOT WATER. Indoor and Outdoor Tankless Gas Water Heaters. Rheem.
Product Brochure Water Heaters Tankless Gas WELC ME TO CONTINUOUS HOT WATER Indoor and Outdoor Tankless Gas Water Heaters Water INTEGRATED Residential HOME Gas COMFORT Tankless Water Heaters Rheem Tankless
More informationDirect Exhaust Venting Kit Instructions
CONDENSING GAS BOILER 220/299/300/399 Direct Exhaust Venting Kit Instructions Evergreen 220/299/300/399 Kit part number 383-500-769 STOP! Read before proceeding Hazard definitions The following defined
More informationRheem Classic. Series Highboy & Lowboy Oil Furnaces with PSC/Direct Drive Motor
THIS MODEL 78% 82% 88% 92.0% 97% Air Oil Furnaces Rheem Classic Series Highboy & Lowboy Oil Furnaces with PSC/Direct Drive Motor ROCA-***P: Highboy Series ROLA-***P: Lowboy Series Input Ratio from 84,000
More informationAqua Balance. Direct Exhaust Venting Kit Instructions
Aqua Balance WMB-155H and WMB-155C Wall Mount Gas-Fired Heating Only Boiler & Combination Boiler Heating and Domestic Hot Water Direct Exhaust Venting Kit Instructions AquaBalance TM WMB-155H & WMB-155C
More informationNCC199CDV Commercial Water Heating System Installation Manual
NCC199CDV Commercial Water Heating System Installation Manual -Additional information can be obtained from the appliance manual. Floor Mount Rack (CDV Units) 6 Water Heaters Floor Mount Rack (w/ VC-6)
More informationWM97+ Wall Mount Boiler
WM97+ Wall Mount Boiler Questions & Answers Models 70, 110 & 155 INSTALLATION 1. Can the boiler be installed in a living area? Yes, the WM97+ is a wall mounted boiler. The sealed combustion and internal
More informationHydronic Air Handler Powered by Tankless Technology
Integrated Solutions Hydronic Air Handler Powered by Tankless Technology ECM Motor Nominal Heating Capacities: 40-100 kbtu [11.7-29. kw] Tankless Water Heater Models: RTG-64DVL indoor direct vent and RTG-64XL
More informationOn-Demand Water Heater Installation Manual and Owner s Guide
On-Demand Water Heater Installation Manual and Owner s Guide R D R ANSI Z21.10.3 CSA 4.3 Models 540P Indoor 540P Outdoor WARNING If the information in these instructions is not followed exactly, a fire
More informationInstallation Instructions for use by heating contractor. Vitodens Common Venting System IMPORTANT
Installation Instructions for use by heating contractor Common venting for Vitodens 200 B2HA 45 to 530 Vitodens 200 B2HB 45, 57, 160, 199 Vitodens Common Venting System Product may not be exactly as shown
More informationZ-DENS Polypropylene Vent Systems
Z-FLEX Advanced Venting Solutions Z-DENS Polypropylene Vent Systems for High Efficiency Condensing Appliances Single Wall Rigid Flexible Liner Cascade Concentric Affirmed as replacement to comparable PVC
More informationHydronic Air Handler Powered by Tankless Technology
Integrated Solutions Hydronic Air Handler Powered by Tankless Technology RHWB- Series Nominal Heating Capacities: 32-90 kbtu [9.38-26.39 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in
More informationMFC Series Boiler Vent and Combustion Air Guide
Pre-Installation Application Guide MFC Series Boiler Vent and Combustion Air Guide Applies to Models 3000 through 10000 Exhaust venting, combustion air and piping Requirements for MFC Series boilers Other
More informationKit Instructions COMMON VENT KIT (PVC AND DURAVENT)
Kit Instructions COMMON VENT KIT (PVC AND DURAVENT) CONTENTS. Introduction 2. PVC Common Vent Kit Instructions (See Page 3) 3. Polypropylene Common Vent Kit Instructions(See Page 9) SERVICING SHOULD ONLY
More informationVSL II QUICK START GUIDE
This Quick Start Guide must be left with owner and should be hung on or adjacent to the boiler for reference. VSL II QUICK START GUIDE DIRECT-VENT SEALED COMBUSTION CONDENSING BOILER ~ GAS-FIRED BOILER
More informationInstallation and Maintenance Instructions
Installation and Maintenance Instructions Saf-T Vent Model EZ Seal Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada) For
More informationInstallation guide and material checklists
Featuring Flexibility Installation guide and material checklists Series 3 This guide must only be used by a quali!ed heating installer/service technician. Read all instructions, including the boiler manual
More informationTankless Rack System and Common Venting System Introduction. August 9, 2012
Tankless Rack System and Common Venting System Introduction August 9, 2012 Back to Back 8-unit System with Common Venting System CVent PPtl exhaust vent header PVC intake venting (Sche. 40) RU98i Condensing
More informationFLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS
CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-08 Listing No. MH26687 Testing No. 11EN
More informationFOR YOUR SAFETY WARNING FOR YOUR SAFETY. high efficiency, separated combustion gas-fired unit heaters models PTC and BTC
6-563.7 5H0807150000 November, 2014 Model PTC installation and service manual high efficiency, separated combustion gas-fired unit heaters models PTC and BTC WARNING 1. Improper installation, adjustment,
More informationDURAVENT POLYPRO VENTING PRODUCTS
DURVENT POLYPRO VENTING PRODUCTS INDEX FLEX VENTING SYSTEM DPTER KIT... 14-11 -VENT RETROFIT DPTERS... 14-10 CHIMNEY CP... 14-10 CHIMNEY LINING KIT... 14-10 CHIMNEY SUPPORT... 14-11 COUPLER DPTER... 14-12
More informationVenting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4
GOLD GV Water Boiler Series 3 & 4 Venting Supplement Direct Vent Through-Roof or Through-Unused-Chimney For use with Weil-McLain Through-Roof or Through- Unused-Chimney Termination Kit Kit part # 382-200-435
More informationiq1001, Gen II Submittal Data
, Gen II Submittal Data Date: Project Name: Bid Date: Fuel Type: Natural Gas Propane Project #: City State Zip: Engineer: Contractor: Factory Option: intouchbms KEY FEATURES Multiple Stainless (316L) Heat
More informationBid Date: Date: Project Name: Project #: City/St/ZIP: Fuel Type: Natural Gas Propane. Engineer: Factory Option: Contractor: Key Features.
iq751 Submittal Data Date: Bid Date: Project Name: Project #: City/St/ZIP: Engineer: Contractor: Fuel Type: Natural Gas Propane Factory Option: intouch-bms Key Features Multiple Stainless (316L) heat exchanger
More informationInstallation Manual. Vent Kit for Condensing Tankless Gas Water Heater
Installation Manual NORITZ AMERICA CORPORATION Vent Kit for Condensing Tankless Gas Water Heater Model: N-FlexKit2"-35 Applicable Model NRC663-FSV Potential dangers from accidents during installation and
More informationAir-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse
TANKLESS HIGH EFFICIENCY CONDENSING WATER HEATERS COMMERCIAL-GRADE RESIDENTIAL / COMMERCIAL Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to.95 Uniform Energy Factor
More information200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual
M2i-VAM-2 Cast iron condensing boiler 200i Vent/air manual Installation instructions for vent and air piping Also read and follow: 200i Boiler manual 200i Control manual This manual is intended only for
More informationTankless Condensing High Efficiency Water Heaters
Tankless Residential Water Heater Series Tankless Condensing High Efficiency Water Heaters Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to an unprecedented.95 Uniform
More informationWELCOME TO CONTINUOUS HOT WATER
WELCOME TO CONTINUOUS HOT WATER Indoor and Tankless Gas Heaters I Residential Gas Tankless Heaters RHEEM CLASSIC SERIES Hot water on demand from Rheem for higher energy savings with greater security and
More informationT-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh
PRODUCT SPECIFICATIONS GAS UNIT HEATERS / DUCT FURNACES TU T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ Bulletin No. 20402 November 207 Supersedes November 206
More informationPolyPro: For Venting Condensing Appliances Environmentally Safe Alternative Lower Over-All Cost Than PVC Engineered Terminations Fast, Easy To Install
PolyPro : For Venting Condensing Appliances Environmentally Safe Alternative Lower Over-All Cost Than PVC Engineered Terminations Fast, Easy To Install Being Green, Being Responsible. DuraVent looks for
More informationAddendum H to Brute LX 1295A Document 1372
Page 6 BRADFORD WHITE CORP. 1.11 Unpacking and the Installation Kit All 's are shipped in a single box with an Installation Kit. See Figure 4. Unpack the unit and check that all components shown are included
More informationBack to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions
Installation instructions Cascade Venting System for RTG 199HE Back to back Basic Set for units 1 and 2-7 736 501 253 6 720 811 762 / 238-50973-00A (2014/05) Table of contents Table of contents 1 Key to
More informationTankless Condensing High Efficiency Water Heaters with Built-In Pump
Tankless Residential Water Heater Series Tankless Condensing High Efficiency Water Heaters with Built-In Pump Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to an unprecedented
More informationPrestige Gas Vent Stainless Termination Kit
Kit Part Number: Prestige Gas Vent Stainless PSVKIT01 3 Inch Vent System Screening Exterior Black Plate Interior Plate PSVKIT02 4 Inch Vent System Face Plate Recommended tools: Phillips Screwdriver Core
More informationIntro to Commercial Tankless Technology
Rinnai America Corporation 103 International Drive Peachtree City, GA 30269 Telephone: (678) 829-1700 Fax: (678) 364-8643 Toll Free:(800) 621-9419 Email: marketing@rinnai.us Web: www.rinnai.us Intro to
More informationGas Piping Facts. Information for properly sizing gas lines for use with tankless water heaters and other gas appliances TANKLESS WATER HEATING
TANKLESS WATER HEATING Gas Piping Facts Information for properly sizing gas lines for use with tankless water heaters and other gas appliances With any gas appliance, it is essential that the gas supply
More informationUTICA BOILER. SSV Submittal. Project Name: Project Location: Contractor:
UTICA BOILER SSV - 399 Submittal Engineer: Project Name: Project Location: Contractor: APPLICATION: Gas fired hot water heating boiler for indoor installations. Approved for closet or alcove installations.
More informationRheem Classic Series Multi-position Gas Furnaces
Gas Furnaces Rheem Classic Series Multi-position Gas Furnaces R95P- Series 95% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance
More informationInstallation Manual. Vent Kit for Condensing Tankless Gas Water Heater
Installation Manual NORITZ AMERICA CORPORATION Vent Kit for Condensing Tankless Gas Water Heater Model: N-FlexKit2"-35 Applicable Model NRC663-FSV Potential dangers from accidents during installation and
More informationSTS-JZ (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS
SUBMITTAL DATA (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS PROJECT: ENGINEER: CONTRACTOR: DISTRIBUTOR: SCHWANK MODEL #: FUEL: APPROVED BY: DATE: APPROVAL #: 1 Submittal NOTICE:
More informationEsteem 399 Low NOx Gas Fired Boiler
Instruction No. AERCO INTERNATIONAL, Inc. Northvale, New Jersey, 07647 USA PVC & CPVC Vent Installation Supplement Esteem 399 Low NOx Gas Fired Boiler I S T E D L Visit www.aerco.com to View the Latest
More informationULC S636 System. PolyPro. PolyPro Flex. Terminations
PolyPro Polypropylene venting products for high-efficiency condensing appliance installations. Chloride free, environmentally safe. Listed to ULC-S636. Specifications pplications PolyPro is a polypropylene
More informationCommercial Gas Water Heaters
CYCLONE Mxi MODULATING MODULATING BURNER ADVANCES THE CYCLONE TO HIGHER LEVELS OF EFFICIENCY The full line of A. O. Smith Cyclone Mxi condensing water heaters has been designed to provide years of dependable
More informationInstallation Instructions
Installation Instructions Vent/Exhaust Pipe External Trap Kit KGAET0101ETK Table 1 Kit Contents PART DESCRIPTION PART NO. QUANTITY Condensate Trap 308589-402 1 Tee-Vent Fitting (2-in. PVC) 321496-301 1
More informationCommercial Gas Water Heaters
CYCLONE Mxi MODULATING MODULATING BURNER ADVANCES THE CYCLONE TO HIGHER LEVELS OF EFFICIENCY The full line of A. O. Smith Cyclone Mxi condensing water heaters has been designed to provide years of dependable
More informationMECHANICAL VENTING VERSATILITY
MODULATING ULTRA FORCE HIGH EFFICIENCY POWER VENT The full line of State Modulating Ultra Force High Efficiency Power Vent condensing water heaters has been designed to provide years of dependable service
More informationBy Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference
By Bernard Dalsin Mfg. Co. 5205 208 th St Farmington MN 55024 L-VENT TYPE 3 "and 4" Factory-built venting system for wood pellet, corn or biomass and low-temperature gas or liquid fuel appliances Installation
More informationMERIT SERIES Downflow
PRODUCT SPECIFICATIONS GAS FURNACES ML95DF MERIT SERIES Downflow Bulletin No. 06 February 08 Supersedes November 07 MODEL NUMBER IDENTIFICATION AFUE - 95% Input - 44,000 to 0,000 Btuh Nominal Add-on Cooling
More informationRheem Classic Plus Series Two Stage Multi position Gas Furnaces
Gas Furnaces Rheem Classic Plus Series Two Stage Multi position Gas Furnaces R96P- Series 96% A.F.U.E. * Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] A.F.U.E. (Annual Fuel Utilization Efficiency)
More informationOn-Demand Water Heater Installation Manual and Owner s Guide
On-Demand Water Heater Installation Manual and Owner s Guide ANSI Z21.10.3 and CSA 4.3 140 Indoor (T-H3M-DV) Model 140 Outdoor (T-H3M-OS) WARNING If the information in these instructions is not followed
More informationINSTALLATION AND SERVICE MANUAL
INSTALLATION AND SERVICE MANUAL VERTICAL COMBUSTION AIR INLET KITS CATEGORY III VENTING FOR SEPARATED COMBUSTION TUBULAR GAS FIRED UNIT HEATERS USE 5 INCH KIT FOR UNITS WITH CAPACITIES 100,000 TO 250,000
More informationSaf-T Vent Model EZ Seal Plus/EZ 316 Single Wall Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada)
Installation and Maintenance Instructions Saf-T Vent Model EZ Seal Plus/EZ 316 Single Wall Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada) For Venting Residential,
More informationSide by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions
Installation instructions Cascade Venting System for RTG 199HE Side by side 6720804520-20.1V Extension Set for units 3 or 4-7 736 501 254 6 720 811 761 / 238-50976-00A (2014/05) Table of contents Table
More informationOn-Demand Water Heater Installation Manual and Owner s Guide
On-Demand Water Heater Installation Manual and Owner s Guide R D R ANSI Z21.10.3 CSA 4.3 540 model only Gas Tankless Water Heater TM Suitable for combination potable water heating and space heating. Please
More informationInstallation Operation Maintenance
Installation Operation Maintenance 2008 Heat Transfer Products, Inc. If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or
More informationNAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA
Navien America Inc. Specification Details for the Navien models: CR-210 CR-210A For Indoor Installation Only For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA,
More informationEasy Installation & Service
Water Commercial Electric Heavy Duty Water Heaters Heavy Duty Electric commercial water heaters are available in 50 through 175 gallon capacities. All models quick ship from Rheem warehouses no deposit
More informationEngineering Submittal Data PPRTH Patio Radiant Tube Heaters.
12288 Brawn Road 22, Wainfleet, Ontario, Canada L0S 1V0 Phone: 905-899-3473 Fax: 905-899-2262 www.easyradiantworks.com email: erw@vaxxine.com P For either indoor or outdoor installation. Not for use in
More informationPVC, CPVC, PP & SS Vent Supplement
PVC, CPVC, PP & SS Vent Supplement This document is intended to be used by a qualified heating contractor or service technician. Read all instructions within this document and within the CHAL- LENGER Installation
More informationG61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.
P R O D U C T S P E C I F I C AT I O N S G A S F U R N A C E S G6MP ELITE Series Multi-Position - Two-Stage Heat Bulletin No. 038 August 009 Supersedes December 008 AFUE - Up to 95% Input - 44,000 to 3,000
More informationTankless Water Heaters
John Wood powered by Takagi offers a wide selection of tankless products to suit the varying needs of today s households. A full product line of state-of-the-art tankless water heaters, including condensing
More informationCOMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS
CONDENSING TANKLESS WITH INTEGRATED RECIRCULATION PUMP COMMERCIAL-GRADE RESIDENTIAL Ultra-Low NOx gas tankless water heaters with condensing technology featuring an up to 0.95 Uniform Energy Factor (UEF)
More informationInstallation Instructions for use by heating contractor
Installation Instructions for use by heating contractor Vitocrossal 300 CU3A Rigid and Flex Pipe Venting Systems Product may not be exactly as shown Read and save these instructions for future reference.
More informationInstallation and Maintenance Instructions
Installation and Maintenance Instructions Saf-T Vent Model EZ Seal and Model GC Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II
More informationRheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu
THIS MODEL 80.0% 78% 82% 88% 97% Air Gas Furnaces Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2 System RGLE- Series 80% A.F.U.E. Input Rates 75-125 kbtu ENER
More informationUser s Information Manual Models:
FB-USER Rev C User s Information Manual Models:1.5-5.0 WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury
More informationVSL II QUICK START GUIDE
This Quick Start Guide must be left with owner and should be hung on or adjacent to the boiler for reference. VSL II QUICK START GUIDE DIRECT-VENT SEALED COMBUSTION CONDENSING BOILER ~ GAS-FIRED BOILER
More informationMULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:
TANKLESS CONDENSING HIGH EFFICIENCY COMMERCIAL GAS Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to 0.95 Uniform Energy Factor (UEF) which lowers operating costs and
More informationINSTALLATION AND SERVICE MANUAL
INSTALLATION AND SERVICE MANUAL HORIZONTAL COMBUSTION AIR INLET KITS CATEGORY III VENTING FOR SEPARATED COMBUSTION TUBULAR GAS FIRED UNIT HEATERS USE 5 INCH KIT FOR UNITS WITH CAPACITIES 100,000 TO 250,000
More informationCHAPTER 8 CHIMNEYS AND VENTS
CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.
More informationSMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD
CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-08 Listing No. MH26687 Testing No. 11EN
More informationInstallation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro
Installation Instructions PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances PolyPro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES)
More informationPhantom-X 399C/500C. Residential High Efficiency Gas Boilers PHNTM399C, PHNTM500C Submittal Sheet. Wholesaler Job Name Mechanical Contractor
PHNTM Floor Standing Heating s Phantom-X 399C/500C Residential High Efficiency Gas s PHNTM399C, PHNTM500C Submittal Sheet Wholesaler Job Name Mechanical Contractor Number Gas Type BTU/hr INPUT BTU/hr OUTPUT
More informationFire Tube Combi Boiler Installation & Service Manual Models:
100275091_2000533998_Rev M FIRE TUBE COMBI Fire Tube Combi Boiler Models: 110-199 This manual must only be used by a qualified heating installer / service technician. Read all instructions, in this manual
More informationMASTERTEMP HEATER REPLACEMENT PARTS
0 Section. Maintenance/Replacement Parts Electrical System (Key Nos. through 4), See Page 2 Burner System (Key Nos. through ), See Page 4 Water System (Key Nos. through ), see Page 2 Repair Parts are available
More informationFlues and chimney systems
Flues and chimney systems Complete systems overview Table of content About us 02 Portfolio overview 03 Timeline 04 Gas flue systems 06 Chimney systems rigid single-wall 08 Chimney systems flexible single-wall
More informationRHEEM NATIONAL PARTS SERVICE CENTER
RHEEM NATIONAL PARTS SERVICE CENTER 2007 Parts Guide for water heating systems Contractor s Reference Preferred Parts The premium line approved for replacement in Rheem and Ruud residential water heaters
More informationSAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse
CONDENSING TANKLESS WITH INTEGRATED RECIRCULATION PUMP COMMERCIAL-GRADE RESIDENTIAL Ultra-Low NOx gas tankless water heaters with condensing technology featuring an up to 0.95 Uniform Energy Factor (UEF)
More information