Hardware Maintenance. CS 615 Aspects of System Administra7on Majed Almakfi

Size: px
Start display at page:

Download "Hardware Maintenance. CS 615 Aspects of System Administra7on Majed Almakfi"

Transcription

1 Hardware Maintenance CS 615 Aspects of System Administra7on Majed Almakfi 1

2 Outline Maintenance Basics Maintenance Contracts Hardware Handling: Circuit Board Monitor Memory Preven7ve Maintenance Environmental Aspects Power Racks Tools 2

3 Maintenance Basics Providing a healthy, well- maintained environment for computers is as important as ever. Maintenance contract rates are typically 10%- 12% of component s list price per year. What about Log Book? What is the best maintenance scheme? 3

4 Maintenance Contracts On- site Maintenance Board swap Maintenance 4

5 Hardware Handling When maintaining, repairing or upgrading your PC, think about 5

6 Hardware Handling: Circuit Boards Should be handled gently. Sensi7ve to sta7c electricity 6

7 Hardware Handling: Monitor Monitors owen use internal charges of tens of thousands of volts that can be persist long awer the power disconnected. High risk of electric shock. 7

8 Hardware Handling: Memory Memory is more sensi7ve than anything else to sta7c electricity. The connector that s used is varies. Use appropriate tool 8

9 Preventive Maintenance Some pieces of hardware have filters that must regularly cleaned or changed. Blow dust out of all equipments. Check CPU fan for noise or other problems. Does the Power supply, CPU, Hard drives, or any other components feel too hot? Anything with moving parts may need lubrica7on. 9

10 Environmental Aspects As humans, computers work be_er and longer if they re happy in their environment. Although they don t care much about having a window with nice view, you do need to pay a_en7on to other aspects of their home. 10

11 Environmental Aspects: Temperature Commercial- Grade chips have an opera7onal range up to about 120 F. More than 160 F (71 C), they break. 80 F (27 C) in the computer room means 120 F(49 C) inside machine. What is the ideal opera7ng temperature of computer room? 11

12 Environmental Aspects: Humidity Low Humidity High Humidity What is the ideal opera7ng humidity of computer room? 12

13 Environmental Aspects: Cooling BTUH is stand for Bri7sh Thermal Unit Per Hour which is amount of heat that produced by an object. Example: 25 Servers 6 fixtures (4 fluorescent tubes in each) 4 operators Roof, walls, and windows How we calculate how much the cooling required? 13

14 Environmental Aspects: Cooling (Cont.) Servers (25 Servers) X (450 wa_s) X (3.412 BTUH) = 38,385 BTUH Light Fixtures (6 fixtures) X (160 wa_s) X (3.412 BTUH) = 3,276 BTUH Operators (4 humans) X (300 BTUH) = 1,200 BTUH Roof, Walls, and Windows (Done by HVAC) = 20,000 BTUH The total heat load = BTUH Conver7ng to Ton: (62,681 BTUH) / (12000 BTUH) X (1.5) = 7.86 tons 14

15 Environmental Aspects: Cooling (Cont.) What about the huge data center? 15

16 Environmental Aspects: Water Cooling Modular Water Cooling System: used within a fully sealed cabinet and is mounted at the bo_om of the rack. 16

17 Environmental Aspects: Water Cooling Door Units: A door unit replaces a standard server rack door with a door that contains sealed tubes filled with cooled water. 17

18 Environmental Aspects: Water Cooling Heat Exchanges for Hot Spots: Heat exchangers are fed with cooled water that circulate cool air directly over hot spots that use the same cooling system as a Computer Room Air Condi7oners (CRAC) unit in the data center. 18

19 Environmental Aspects: Water Cooling Mountable Liquid Cooling Devices: This solu7on works at the CPU or device level. A sealed plate that is on top of the CPU has coolant running through it provides cooling to the CPU. 19

20 Environmental Aspects: Air Cooling Chiller: The chiller produces cooled water by a refrigera7on process and delivers water to the computer room air handler. 20

21 Environmental Aspects: Air Cooling Computer Room Air Handler (CRAH): The air handler is installed at the data center floor and is connected to the outside chiller unit. This system pushes air through the data center with a fan system. 21

22 Environmental Aspects: Air Cooling Humidifier: The humidifier is usually installed with the CRAC / CRAH system. The humidifier will replace water loss before air leaves the A/C. 22

23 Environmental Aspects: Air Cooling Air Condi7oners: Also called (CRAC) Computer Room Air Condi7oners are usually installed at the floor of a data center and connected to an outside condensing unit. Air is pushed through the data center with a fan system. 23

24 What is the Best Cooling System? 24

25 Environmental Aspects: Facebook Evapora7ve cooling system: This system evaporates water to cool the incoming air, as opposed to tradi7onal chiller systems that require more energy intensive equipment. This process is highly energy efficient and minimizes water consump7on by using outside air. Airside economizer: The facility will be cooled by simply bringing in colder air from the outside. This feature will operate for between 60 percent and 70 percent of the year. The remainder of the year requires the use of the evapora7ve cooling system to meet temperature and humidity requirements. Re- use of server heat: A por7on of the excess heat created by the computer servers will be captured and used to heat office space in the facility during the colder months. 25

26 Environmental Aspects: Yahoo Each 120- foot by 60- foot Yahoo Compu7ng Coop module has louvers along the side of the building that allow fresh air to enter into the data center. In the equipment area, the fresh air enters the front of the servers, and then exits into a contained hot aisle, which is topped by a chimney that leads into the upper chamber of the coop. The Lockport data center will operate without chillers. The facility will use an evapora7ve cooling system during some days in summer when it is too warm to use fresh air. The buildings were posi7oned on the Lockport property to allow Yahoo to bring in cool air from either side of the coop, based on the prevailing winds. 26

27 Power 13% of the electrical power consumed in US to run computers. Use UPS in server room. Why? Remote Monitoring!! 27

28 Racks Used to store equipments All cables terminated on Rack What is the best overhead track system? 28

29 Tools A well- oupi_ed system administrator is an effec7ve system Administrator. What kind of tools? 29

30 Tools: General Tools 30

31 Tools: General Tools (Cont.) 31

32 Tools: Computer Related Tools 32

33 Tools: Computer Related Tools (Cont.) 33

34 Tools: Miscellaneous Tools 34

35 Questions?? 35

36 References Unix System Administra7on Handbook,3rd Edi7on,Nemeth et al: Chap. 24 h_p:// h_p:// talk/techie- talk- hardware/94- safely- handling- your- pc- components h_ps:// 2010/09/20/inside- the- yahoo- compu7ng- coop/ h_ps:// post= h_p://networkmonitorsowware.net/data- center- cooling 36

Ductless and ducted mini splits- with case studies. Heat Pump and Air Condi1oning For Energy Design Conference By Mike D. Wilson- Dakota Supply Group

Ductless and ducted mini splits- with case studies. Heat Pump and Air Condi1oning For Energy Design Conference By Mike D. Wilson- Dakota Supply Group Ductless and ducted mini splits- with case studies Heat Pump and Air Condi1oning For Energy Design Conference By Mike D. Wilson- Dakota Supply Group In accordance with the Department of Labor and Industry

More information

gforce Units Data Aire and Data Temp Series

gforce Units Data Aire and Data Temp Series gforce Units gforce gforce is the most advanced mission critical cooling equipment available on the market today. These units are the most efficient and economical while complying with strict environmental

More information

How to Select an Industrial PC with I/O for a Wide Temperature Application

How to Select an Industrial PC with I/O for a Wide Temperature Application Acromag, Incorporated 30765 S Wixom Rd, PO Box 437, Wixom, MI 48393-7037 USA Tel: 248-295-0310 Fax: 248-624-9234 www.acromag.com White Paper: How to Select an Industrial PC with I/O for a Wide Temperature

More information

The 7 attributes of highly effective quick disconnect couplings for liquid cooling of computers and servers

The 7 attributes of highly effective quick disconnect couplings for liquid cooling of computers and servers WHITE PAPER The 7 attributes of highly effective quick disconnect couplings for liquid cooling of computers and servers By Dennis Downs Business Unit Manager Colder Products Company St. Paul, Minnesota

More information

Class 1: Basic Refrigera0on Cycle. October 7 & 9, 2014

Class 1: Basic Refrigera0on Cycle. October 7 & 9, 2014 Class 1: Basic Refrigera0on Cycle October 7 & 9, 2014 Refrigeration Cycle 4 key components needed in a basic refrigera0on cycle: 1. Compressor 2. Condenser 3. Evaporator 4. Metering Device Compressor Compressor

More information

DIGI-CRAC DIGI-CRAH South 59 th Street Omaha, NE bes- tech.net

DIGI-CRAC DIGI-CRAH South 59 th Street Omaha, NE bes- tech.net Digi-CRAC/H DIGI-CRAC Digi-CRAC is an aftermarket control package designed for DX data center air-conditioning units. Modulating the compressor and fan speed to match output to the space needs. DIGI-CRAH

More information

Infrared Heaters For Controlled Concentrated Curing

Infrared Heaters For Controlled Concentrated Curing Infrared Heaters For Controlled Concentrated Curing Model 6020 Infrared Heat. Instantaneous Results. The Model 6020 DryIR infrared heater is designed for drying applications that require a clean, responsive,

More information

Advance Pay. energy use guide

Advance Pay. energy use guide Advance Pay energy use guide There s no way my house used that much electricity! We hear you, and we re here to help! The more you know about where your electricity dollars are going, the better you can

More information

Business Energy Efficiency Incentives 2007

Business Energy Efficiency Incentives 2007 Business Energy Efficiency Incentives 2007 1 DSM s Energy & Environmental Impact since 1981 9,378,000,000 kwh 2 1 Year Round Savings on EnergyWise 2 Cars driven 12,000 Miles Progress Energy Growth Trend

More information

Liquid cooling and heat re-use experiences. Gert Svensson Dep. Director PDC, KTH November 11, 2015

Liquid cooling and heat re-use experiences. Gert Svensson Dep. Director PDC, KTH November 11, 2015 Liquid cooling and heat re-use experiences Gert Svensson Dep. Director PDC, KTH November 11, 2015 Contents PDC Overview Heat re-use at PDC Liquid cooling Case studies KTH and PDC KTH Royal Institute of

More information

Explanation of Cooling and Air Conditioning Terminology for IT Professionals

Explanation of Cooling and Air Conditioning Terminology for IT Professionals Explanation of Cooling and Air Conditioning Terminology for IT Professionals White Paper #11 Revision 1 Executive Summary As power densities continue to increase in today s data centers, heat removal is

More information

Technical Report #3 Mechanical Systems Existing Conditions Evaluation

Technical Report #3 Mechanical Systems Existing Conditions Evaluation Mechanical Option Technical Report #3 Technical Report #3 Mechanical Systems Existing Conditions Evaluation Instructor: Dr. Bahnfleth 11.15.04 Building Sponsor: CCG Facilities Integration Table of Contents

More information

Doing More with Less: Cooling Computers with Immersion Pays Off

Doing More with Less: Cooling Computers with Immersion Pays Off ANALYST REPORT National Security Agency Doing More with Less: Cooling Computers with Immersion Pays Off Republished by GRC 2018 Author: David Prucnal, PE Original Publication: The Next Wave Vol. 20 No.

More information

How Air Conditioners Work by Marshall Brain

How Air Conditioners Work by Marshall Brain Search HowS Computer Stuff Auto Stuff Electronics Stuff Science Stuff Home Stuff Stuffo Health Stuff Mon Main > Home > Home Appliances How Air Conditioners Work by Marshall Brain Click here to go back

More information

COMMERCIAL HVAC EQUIPMENT Indoor Self-Contained Units

COMMERCIAL HVAC EQUIPMENT Indoor Self-Contained Units COMMERCIAL HVAC EQUIPMENT Indoor Self-Contained Units Technical Development Program Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection

More information

COMMERCIAL ENERGY SAVINGS GUIDE

COMMERCIAL ENERGY SAVINGS GUIDE COMMERCIAL ENERGY SAVINGS GUIDE www.touchstoneenergy.com/bea www.touchstoneenergy.com/bea USING ENERGY MORE EFFICIENTLY IMPROVES YOUR BOTTOM LINE. Cooperatives and their commercial members share a common

More information

Performance Climate Changer Next generation air handler from Trane

Performance Climate Changer Next generation air handler from Trane Performance Climate Changer Next generation air handler from Trane Trane Performance Climate Changer Air Handler Two-inch, R-13 foam-injected panels with mid-span, internal thermal breaks and standard

More information

Urbana Free Library HVAC Analysis. Prepared for the Urbana Free Library. Prepared by Paul Boland, P.E., and Nathan Alderman, E.I.T.

Urbana Free Library HVAC Analysis. Prepared for the Urbana Free Library. Prepared by Paul Boland, P.E., and Nathan Alderman, E.I.T. Urbana Free Library HVAC Analysis Prepared for the Urbana Free Library Prepared by Paul Boland, P.E., and Nathan Alderman, E.I.T. Report Dated August 8, 2016 1. Introduction The Urbana Free Library is

More information

DOCUMENT TABLE OF CONTENTS

DOCUMENT TABLE OF CONTENTS DOCUMENT 00003 June 16, 2005 TABLE OF CONTENTS DOCUMENT NO. INTRODUCTORY INFORMATION DOCUMENT 00003 TABLE OF CONTENTS DIVISION 1 GENERAL REQUIREMENTS SECTION 01011 SECTION 01025 SSP21.1-1 SECTION 01026

More information

Fundamental Principles of Air Conditioners for Information Technology

Fundamental Principles of Air Conditioners for Information Technology Fundamental Principles of Air Conditioners for Information Technology By Tony Evans White Paper #57 Revision 2 Executive Summary Every Information Technology professional who is responsible for the operation

More information

ENGINEERING. Edition No. 13 October 2002

ENGINEERING. Edition No. 13 October 2002 Edition No. 13 October 2002 ENGINEERING S Y S T E M S O L U T I O N S W e at McQuay are very proud of our tradition of producing industry leading water source heat pumps. Our heritage stretches back more

More information

High Five for Saving Energy!

High Five for Saving Energy! High Five for Saving Energy! 1. Heat offices and classrooms to 68 F Turing the heat down by 1 F will save 3% of the energy needed to heat that space. 2. Keep doors and windows closed Every hour a window

More information

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance Temperature & Humidity Control Systems Design & Manufacturing DX Air / Water / Glycol Cooled Air and Water Side Economizer Chilled Water Systems Eco-Friendly High Performance OPTIMAL COOLING SOLUTIONS

More information

Thermal management architectures for rack based electronics systems. Sukhvinder Kang, David Miller Aavid Thermalloy, Concord NH, USA

Thermal management architectures for rack based electronics systems. Sukhvinder Kang, David Miller Aavid Thermalloy, Concord NH, USA Thermal management architectures for rack based electronics systems Sukhvinder Kang, David Miller Aavid Thermalloy, Concord NH, USA 2011 MEPTEC HEAT IS ON SYMPOSIUM, SAN JOSE, March 21-22, 2011 Abstract

More information

Power Savings Running LINPACK Liquid Cooled

Power Savings Running LINPACK Liquid Cooled Power Savings Running LINPACK Liquid Cooled Steve Harrington, Ph.D. Lecturer In Aerospace Engineering, UCSD October 24, 2012 Introduction Problem: Modern HPC Systems Need Power & Density Solution: Liquid

More information

AmpLight Lighting Management System

AmpLight Lighting Management System AmpLight Lighting Management System Centralized Streetlight Control Centralized Streetlight Control The AmpLight solution is a complete web-based solution with advanced communication and easy integration

More information

LOWERING THE COST OF HIGH CEILINGS

LOWERING THE COST OF HIGH CEILINGS LOWERING THE COST OF HIGH CEILINGS in partnership with The Carbon Trust recommends destratification as an effective energy-saving strategy.* WHY CHOOSE ZOO FANS? Fast Payback ZOO Fans create even temperatures

More information

International Journal on Emerging Technologies 4(2): 42-46(2013) ISSN No. (Print) : ISSN No. (Online) :

International Journal on Emerging Technologies 4(2): 42-46(2013) ISSN No. (Print) : ISSN No. (Online) : e t International Journal on Emerging Technologies 4(2): 42-46(2013) ISSN No. (Print) : 0975-8364 ISSN No. (Online) : 2249-3255 Reduce Chiller and Server Power, and Removing Heat Transfer for Liquid Cooling

More information

EVLA Memorandum 107 Failure Pathology of EVLA WIDAR Correlator Support Systems October 18 th, 2006 Bob Broilo, Brent Carlson

EVLA Memorandum 107 Failure Pathology of EVLA WIDAR Correlator Support Systems October 18 th, 2006 Bob Broilo, Brent Carlson EVLA Memorandum 107 Failure Pathology of EVLA WIDAR Correlator Support Systems October 18 th, 2006 Bob Broilo, Brent Carlson INTRODUCTION The WIDAR correlator being developed for the EVLA project will

More information

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS DCA4 Digitally controlled Audio Matrix Product Specification March 2002 Current Thinking Document Number DDC DCA 7001 01 ACS Introduction Voice Alarm (VA) systems are the quickest way to evacuate the public

More information

GARCIA GALUSKA DESOUSA Consulting Engineers

GARCIA GALUSKA DESOUSA Consulting Engineers L#57297 /Page 1/July 21, 2017 ELECTRICAL SYSTEMS NARRATIVE REPORT The following is the Electrical Systems narrative, which defines the scope of work and capacities of the Power and Lighting systems, as

More information

Using Portable Spot Air Conditioners in Industrial Applications

Using Portable Spot Air Conditioners in Industrial Applications Using Portable Spot Air Conditioners in Industrial Applications Cooling People, Processes and Equipment In today s highly competitive manufacturing sector, companies are constantly looking for new ways

More information

High Performance Building Guide 1

High Performance Building Guide 1 Description This Guide is intended to be used for projects with a Vermont Certified: High Performance energy efficiency goal. This High Performance goal is a whole-building efficiency approach rather than

More information

Flexible & Innovative. Cooling Solutions

Flexible & Innovative. Cooling Solutions Flexible & Innovative Cooling Solutions Flexible & Innovative Compu-Aire Inc. offers a variety of high performance precision cooling systems that can adapt to your application needs. With today s rapidly

More information

MODUCEL KW DOWNFLOW COOLING DRU DRU DATA ROOM UNITS

MODUCEL KW DOWNFLOW COOLING DRU DRU DATA ROOM UNITS MOUEL 80-10 KW OWNFLOW OOLING RU RU T ROOM UNITS T ROOM UNITS The Moducel range of high efficiency ata Room Units, are designed for high density load areas where a large cooling duty is required from a

More information

Specification for On-Line UPS Battery Monitoring and Data Management System

Specification for On-Line UPS Battery Monitoring and Data Management System 1 Scope This specification defines the minimum requirements for a predictive on-line Battery Monitoring BMDMS with test, analysis, and remote monitoring control capabilities. Unless noted otherwise, the

More information

Building America AC Installation Using CheckMe!

Building America AC Installation Using CheckMe! Prepared by: Proctor Engineering Group, Ltd. San Rafael, CA 94901 (415) 451-2480 Building America AC Installation Using CheckMe! Prepared for: Building Science Corporation Pulte Homes Sierra Air Final

More information

Appendix B. Facilities Assessment Report

Appendix B. Facilities Assessment Report Mile Lane Army Reserve Center Redevelopment Plan September 2008 Appendix B Facilities Assessment Report RKG Associates, Inc. Mile Lane Army Reserve Base Middletown, CT MEP System Evaluation For RKG Associates

More information

H EDRICK ASSOCIATES OF GRAND RAPIDS West Michigan s Factory Representative

H EDRICK ASSOCIATES OF GRAND RAPIDS West Michigan s Factory Representative A U.S. Environmental Protection Agency survey released in 2007 concluded that IT data centers consumed 61 billion kw of electricity at a total cost of $4.5 billion in 2006. As energy costs continue to

More information

Guardian II Pipeline Washer B Instruction Supplement

Guardian II Pipeline Washer B Instruction Supplement Guardian II Pipeline Washer B Instruction Supplement P.O. Box 8050 Madison, WI 53708 608-222-3484 Contents Introduction... 2 1. New Features... 2 1.1 Password For Setup... 2 1.2 Delay... 2 1.3 Date & Time

More information

INSTALLATION MANUAL FOR MODELS: TERAZZA, TRACCIO, MILANO, CERRATO

INSTALLATION MANUAL FOR MODELS: TERAZZA, TRACCIO, MILANO, CERRATO INSTALLATION MANUAL FOR MODELS: TERAZZA, TRACCIO, MILANO, CERRATO TABLE OF CONTENTS ROOM SPECIFICATIONS ELECTRICAL SPECIFICATIONS PLUMBING SPECIFICATIONS TECHNICAL SPECIFICATIONS INTRODUCTION ASSEMBLY

More information

General HVAC Recommendations

General HVAC Recommendations General HVAC Recommendations DESIGN GUIDELINES FOR ENERGY EFFICIENT HVAC SYSTEMS Thank you for your interest in energy efficiency! Energy efficient heating, ventilation, and air conditioning (HVAC) equipment

More information

FOOD SAFETY REQUIREMENTS FOR SPECIAL EVENTS CITY OF ENNIS

FOOD SAFETY REQUIREMENTS FOR SPECIAL EVENTS CITY OF ENNIS FOOD SAFETY REQUIREMENTS FOR SPECIAL EVENTS CITY OF ENNIS TEMPORARY FOOD PERMIT All temporary event food vendors selling food/drinks which are not pre- packaged cannot start service unless a Temporary

More information

Operation Manual WEBASTO BLUE COOL PREMIUM Chilled Water Systems

Operation Manual WEBASTO BLUE COOL PREMIUM Chilled Water Systems Operation Manual WEBASTO BLUE COOL PREMIUM Chilled Water Systems General Information Dear Webasto Customer! This operation manual provides an overview about how to use the compact air condition system

More information

2013 Product Range Precision Air Conditioners (CRAC)

2013 Product Range Precision Air Conditioners (CRAC) 2013 Product Range Precision Air Conditioners (CRAC) 2013 Product Range RC Group air conditioners range CLOSE CONTROL AIR CONDITIONERS 2,0-244,0kW HEAT PUMP AIR CONDITIONERS 6,3-113,0kW 6,3-101,0kW AIR

More information

Proposed Mechanical, Plumbing, and Electrical Systems For the LEDYARD POLICE DEPARTMENT LEDYARD, CT

Proposed Mechanical, Plumbing, and Electrical Systems For the LEDYARD POLICE DEPARTMENT LEDYARD, CT DESIGN ASSOCIATES INC MECH/ELEC DESIGN & CONSULTING 422 Highland Ave, Cheshire, CT. 06410 (203) 271-3787, fax (203) 271-2886 Proposed Mechanical, Plumbing, and Electrical Systems For the LEDYARD POLICE

More information

Controlled Humidity Solutions for Potato Storage

Controlled Humidity Solutions for Potato Storage Controlled Humidity Solutions for Potato Storage 9.2009 Optiguide s Humidity Enhance systems with its Tabor Atomizer and Optiguide Humidistat deliver controlled dry and very high relative humidity up to

More information

Data Centre Cooling Solutions

Data Centre Cooling Solutions Data Centre Cooling Solutions DIGITAL REVOLUTION In 2016 we produced as much data as in the entire history of humankind through 2015. POWER NEEDS It is estimated that 1,5% of globally generated power is

More information

Typical Installation Breaker Box Class A 50 amp, 120/240 volt, GFCI

Typical Installation Breaker Box Class A 50 amp, 120/240 volt, GFCI READ THIS FIRST!!!! TYPICAL GFCI INSTALLATION GUIDELINES ATTENTION ELECTRICIAN: All PDC Spa Units must be installed with an approved G.F.C.I. in accordance with all applicable codes. Installation of G.F.C.I.

More information

A Technical Introduction to Cool Thermal Energy Storage Commercial Applications

A Technical Introduction to Cool Thermal Energy Storage Commercial Applications A Technical Introduction to Cool Thermal Energy Storage Commercial Applications Cool Thermal Energy Storage is a new application of an old idea that can cut air conditioning energy costs in half while

More information

Surna 25-Ton Chiller Operating & Maintenance Manual

Surna 25-Ton Chiller Operating & Maintenance Manual www.surna.com 303.993.5271 Surna 25-Ton Chiller Operating & Maintenance Manual Models: 300F3-3. 300F4-3, 300FW-3 Revised: July 2015 Table of Contents Warranty Information 4 Limited Warranty 4 Limitation

More information

The Economics of Performance Engineering Involvement in Architecture Proposals

The Economics of Performance Engineering Involvement in Architecture Proposals The Economics of Performance Engineering Involvement in Architecture Proposals 2002 Tuesday, December 10, 2002 1 1 908 985-7336 Architecture and Performance Engineering 2! Software performance engineering

More information

Please refer to the drawing and notes for each particular plan view. Site Plan S1-1 Site Drawing. Electrical E1-1 Main Electrical Drawing

Please refer to the drawing and notes for each particular plan view. Site Plan S1-1 Site Drawing. Electrical E1-1 Main Electrical Drawing The property that I discuss is an actual property that I helped to build. My position was as the Facility/Project Manager while the building was under construction. I worked very closely with the Senior

More information

Data Centre Cooling Solutions

Data Centre Cooling Solutions Data Centre Cooling Solutions Heat Exchange Solutions ThermoKey DIGITAL REVOLUTION In 2016 we produced as much data as in the entire history of humankind through 2015. POWER NEEDS It is estimated that

More information

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN Introduction to HVAC Agenda Psychrometrics Human Comfort Heat Transfer Refrigeration Cycle HVAC Terminology HVAC Systems Introduction to HVAC Psychrometrics 2000 TRG-TRC002-EN Properties of Air Dry-bulb

More information

TRANE XLi HEAT PUMPS THE ALL-SEASON COMFORT OF TRANE. Exceptional heating and cooling all year long READ ONLY

TRANE XLi HEAT PUMPS THE ALL-SEASON COMFORT OF TRANE. Exceptional heating and cooling all year long READ ONLY TRANE XLi HEAT PUMPS THE ALL-SEASON COMFORT OF TRANE Exceptional heating and cooling all year long TRANE XLi HEAT PUMPS XL16i XL15i XL14i THE XLi FAMILY OF HEAT PUMPS Welcome home to the highest level

More information

Veritas Appliance Hardware Service Procedure

Veritas Appliance Hardware Service Procedure Veritas Appliance Hardware Service Procedure Replacing a Veritas appliance power supply Document Number: 122 Version: 3.2 (03/06/17) Purpose This document describes the process for replacing a power supply

More information

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG: Submittal 5 Ton Convertible Air Handler TEM3A0C60S51SA SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,

More information

Presented By: John Dolan, P.E.

Presented By: John Dolan, P.E. Variable Speed Compressor Technologies Presented By: John Dolan, P.E. President - Thermosystems, Inc. BS in Mechanical Engineering from UIUC 29 years HVAC Equipment Application Experience jdolan@thermohvac.com

More information

_formatted. Number: Passing Score: 800 Time Limit: 120 min File Version: 1.0

_formatted. Number: Passing Score: 800 Time Limit: 120 min File Version: 1.0 220-701_formatted Number: 220-701 Passing Score: 800 Time Limit: 120 min File Version: 1.0 A+ Essentials Exam Version: 1.0 Modified By Wajdi L. Ahmed Al-Samarrai 2012-2013 Sections 1. Safe Lab Procedures

More information

INTRODUCTION. Heat Pipe Technology, Inc. The Heat Pipe Principle. Recent Heat Pipe Development

INTRODUCTION. Heat Pipe Technology, Inc. The Heat Pipe Principle. Recent Heat Pipe Development INTRODUCTION Heat Pipe Technology, Inc. Heat Pipe Technology, Inc. (HPT) was founded in 1983. With funding from private investors, and a grant from the Department of Energy. HPT began research on a new

More information

CAREL heatersteam Electric Element Steam Humidifiers

CAREL heatersteam Electric Element Steam Humidifiers Suggested Engineering Specifications Section 23 84 13 CAREL heatersteam Electric Element Steam Humidifiers 1. GENERAL SCOPE 1. Furnish and install as indicated on the drawings and plans, in-duct [space]

More information

RIGID DC LIQUID CHILLER

RIGID DC LIQUID CHILLER RIGID DC LIQUID CHILLER Phone: +86-579-8837-9768 Email:info@rigidhvac.com Website: www.rigidchill.com 1 1. WHAT S LIQUID CHILLER? Liquid Chiller cooling refers to cooling by means of the convection or

More information

Design of Multi-Sensors Cooperation Control System for Intelligent Building

Design of Multi-Sensors Cooperation Control System for Intelligent Building Energy and Power Engineering, 2017, 9, 495-502 http://www.scirp.org/journal/epe ISSN Online: 1947-3818 ISSN Print: 1949-243X Design of Multi-Sensors Cooperation Control System for Intelligent Building

More information

AND WORRY-FREE PERFORMANCE

AND WORRY-FREE PERFORMANCE AND WORRY-FREE PERFORMANCE M1200 EXTRA HIGH-EFFICIENCY GAS FURNACES 97+% AFUE iq DRIVE MODULATING 95.1% AFUE TWO-STAGE, VARIABLE- & FIXED-SPEED GAS FURNACES WITH iq DRIVE TECHNOLOGY Turn your home into

More information

Heat sinks for electronic cooling applications

Heat sinks for electronic cooling applications Heat sinks for electronic cooling applications Shubhash V. Jadhav Department of Mechanical Engineering, SVERI s College of Engineering Pandharpur, Introduction The previous century brought the miniaturization

More information

REYES/REINHART FOODSERVICE. Approximately 143,638 sq. ft. on /- Acres. Prince George, Virginia

REYES/REINHART FOODSERVICE. Approximately 143,638 sq. ft. on /- Acres. Prince George, Virginia REYES/REINHART FOODSERVICE Approximately 143,638 sq. ft. on 13.4 + /- Acres Prince George, Virginia REYES FOODS/REINHART FOODSERVICE 8025 QUALITY DRIVE PRINCE GEORGE, VA 23875 SIZE: GROUND: NUMBER OF BUILDINGS:

More information

Cooling the Data Center

Cooling the Data Center Article development led by queue.acm.org doi:10.1145/1721654.1721671 What can be done to make cooling systems in data centers more energy efficient? by Andy Woods Cooling the Data Center Power generation

More information

KA020 Weatherproof Sound Meter Enclosure

KA020 Weatherproof Sound Meter Enclosure KA020 Weatherproof Sound Meter Enclosure The Castle Weatherproof Sound Meter enclosure is designed to make short to medium-term outdoor noise monitoring simple and effective. Dedicated to the Castle SONUS

More information

Control Technologies Fze Ph: E: Sharjah, UAE. M: W:

Control Technologies Fze Ph: E: Sharjah, UAE. M: W: Company Profile 1 2 3 4 5 6 7 Control Technologies Fze (Ctrltech) founded in 2008. It is based at Sharjah Airport Free Zone, Sharjah. We provide our services to all Emirates i.e. Dubai, Sharjah, Abu Dhabi,

More information

touchbga.com TOUCHBGA BGA Rework Station HR6000 User Manual

touchbga.com TOUCHBGA BGA Rework Station HR6000 User Manual TOUCHBGA BGA Rework Station HR6000 User Manual Table of contents 1. HR6000 BGA rework station features 1.1.Safety Instrouctions 1.1.1.Electric Safety 1.1.1.Operation Safety 1.1.3.Environmental requirements

More information

2009 Washington State Non-Residential Energy Code Scott Rushing, PE, LEED AP - Rushing Company Lisa Rosenow, CSBA, LEED AP NEEC

2009 Washington State Non-Residential Energy Code Scott Rushing, PE, LEED AP - Rushing Company Lisa Rosenow, CSBA, LEED AP NEEC 2009 Washington State Non-Residential Energy Code Scott Rushing, PE, LEED AP - Rushing Company Lisa Rosenow, CSBA, LEED AP NEEC Mechanical Systems Agenda Changes in NREC Chapter 11 Changes in NREC Chapter

More information

IT Cooling Solutions. CyberRow. Intelligent air flow control for more efficiency in rack cooling

IT Cooling Solutions. CyberRow. Intelligent air flow control for more efficiency in rack cooling IT Cooling Solutions CyberRow Intelligent air flow control for more efficiency in rack cooling Direct rack air conditioning goes in a new direction An innovative idea ensures precise climate control and

More information

General Surveillance Management Centre. DSS is a flexible, scalable, high reliable and powerful central management system.

General Surveillance Management Centre. DSS is a flexible, scalable, high reliable and powerful central management system. General Surveillance Management Centre Introduction DSS is a flexible, scalable, high reliable and powerful central management system. Client-Server Architecture, Integrating with multiple surveillance

More information

CRESTRON: GREEN LIGHT NETWORK LIGHTING CONTROLS 1

CRESTRON: GREEN LIGHT NETWORK LIGHTING CONTROLS 1 GREEN LIGHT ARCHITECTURAL DIMMING CONTROLS (GLPD) Crestron Green Light and Green Light Express Network Dimming Control Systems are web accessible, network connected dimming control systems that receive

More information

Southwest Air Conditioning

Southwest Air Conditioning Southwest Air Conditioning John Proctor, P.E. Proctor Engineering Group, Ltd. San Rafael, CA 94901 415-451-2480 mail@proctoreng.com SWEEP 2012 Copyright 2012 Proctor Engineering Group, Ltd. Southwest Climate

More information

WineZone Ceiling Mount Ductless Split 15

WineZone Ceiling Mount Ductless Split 15 WineZone Ceiling Mount Ductless Split 15 Requires an HVAC technician to install and charge with R-22 refrigerant. Easy to install. Unit plugs into wall outlet. Industrial grade unit for longer life. Indoor

More information

Installing and operating your Cabinet Cooling System, with Digital Thermostat

Installing and operating your Cabinet Cooling System, with Digital Thermostat NOTE: These instructions are for a standard system, since it is not possible to make separate instructions for every custom system. If you have requested a custom system, please be aware of the differences

More information

Installing and operating your Enclosed Cabinet Cooling System and digital thermostat

Installing and operating your Enclosed Cabinet Cooling System and digital thermostat NOTE: These instructions are for a standard system, since it is not possible to make separate instructions for every custom system. If you have requested a custom system, please be aware of the differences

More information

Active Scanning Beam 2: Controlling Delivery

Active Scanning Beam 2: Controlling Delivery martin.grossmann@psi.ch PSI Winter School for Protons 2010 1 Active Scanning Beam 2: Controlling Delivery Martin Grossmann, C. Bula, M. Eichin, K. Jäggy, G.Martin, A. Mayor, M. Rejzek Center for Proton

More information

Improved Chilled Water Piping Distribution Methodology for Data Centers

Improved Chilled Water Piping Distribution Methodology for Data Centers Improved Chilled Water Piping Distribution Methodology for Data Centers By Isabel Rochow White Paper #131 Executive Summary Chilled water remains a popular cooling medium; however leaks in the piping systems

More information

Your computer system is the lifeblood of your business. Cyber threats are. what you hear most about today. Hacks, viruses and spyware get constant

Your computer system is the lifeblood of your business. Cyber threats are. what you hear most about today. Hacks, viruses and spyware get constant Your computer system is the lifeblood of your business. Cyber threats are what you hear most about today. Hacks, viruses and spyware get constant media attention. But environmental dangers can be just

More information

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection High Sensitivity Smoke Detection Hart XL High Sensitivity Smoke Detection (HSSD) TM is a smoke detection system that is simple to install, commission, service and use yet remains brilliantly capable in

More information

GOLDFIELDS PRIMARY SCHOOL. TENDER SPECIFICATION For ELECTRICAL SERVICES MECHANICAL ENGINEER:

GOLDFIELDS PRIMARY SCHOOL. TENDER SPECIFICATION For ELECTRICAL SERVICES MECHANICAL ENGINEER: GOLDFIELDS PRIMARY SCHOOL TENDER SPECIFICATION For ELECTRICAL SERVICES PROJECT MANAGER: School Support Dunedin ARCHITECTURAL DESIGNER: Katipo Design ELECTRICAL ENGINEER: Pedersen Read Dunedin MECHANICAL

More information

"This is only the scope of work for the project. For more information, interested parties should contact Procurement at

This is only the scope of work for the project. For more information, interested parties should contact Procurement at "This is only the scope of work for the project. For more information, interested parties should contact Procurement at purchasing@stpgov.org to ensure receipt of a full bid package, to be listed as a

More information

Hya$sville Volunteer Fire Department Training. Posi%ve Pressure Ven%la%on (PPV) Concepts

Hya$sville Volunteer Fire Department Training. Posi%ve Pressure Ven%la%on (PPV) Concepts Hya$sville Volunteer Fire Department Training Posi%ve Pressure Ven%la%on (PPV) Concepts Tempest Blower and Safety Carefully read the Opera%on and Maintenance Manual before a

More information

Gas Furnaces Two-Stage, Variable- Speed with iseer

Gas Furnaces Two-Stage, Variable- Speed with iseer Gas Furnaces Two-Stage, Variable- Speed with iseer Tough. Smart. Tappan. TM The Military Wanted Tank-Tough. They Got It. Tappan s reputation for tough, durable products was, in the beginning, cast in iron.

More information

Facility Improvements

Facility Improvements AP-SI-03 BICYCLE RACK ADDITION AP-SI-05 EXTERIOR BENCH ADDITIONS Installation of bike rack will allow for designated and secure storage of bicycles. Installation of exterior benches will provide an outdoor

More information

R 410a Series 10 Johnson Controls

R 410a Series 10 Johnson Controls We have made it easy for you to find a PDF Ebooks without any digging. And by having access to our ebooks online or by storing it on your computer, you have convenient answers with r 410a series 10 johnson

More information

Graded Project. National Electrical Code

Graded Project. National Electrical Code Graded Project National Electrical Code National Electrical Code INTRODUCTION This next portion of your program is a project-based assignment designed for you to demonstrate your understanding of the

More information

Cold Weather Operation Of Cooling Towers

Cold Weather Operation Of Cooling Towers This article was published in ASHRAE Journal, March 2014. Copyright 2014 ASHRAE. Posted at www.ashrae.org. This article may not be copied and/or distributed electronically or in paper form without permission

More information

COOLING SOLUTIONS. A Division Of CAG Purification Inc. SPOT COOLER. 10,000 BTU to 60,000 BTU Capacities L IS T E D ISO 9001, ISO 14001

COOLING SOLUTIONS. A Division Of CAG Purification Inc. SPOT COOLER. 10,000 BTU to 60,000 BTU Capacities L IS T E D ISO 9001, ISO 14001 COOLING SOLUTIONS A Division Of CAG Purification Inc. SPOT COOLER 10,000 BTU to,000 BTU Capacities Standard year warranty 1 Extra year for compressor CM C US L IS T E D ISO 9001, ISO 14001 Portable Spot

More information

SMART METERS ANSWER BOOK HOW YOU WHY ONTARIO WHAT ARE GETTING SMART ABOUT CAN START TO PREPARE NOW PAGE 6 TIME-OF-USE PRICES? PAGE 4 IS INTRODUCING

SMART METERS ANSWER BOOK HOW YOU WHY ONTARIO WHAT ARE GETTING SMART ABOUT CAN START TO PREPARE NOW PAGE 6 TIME-OF-USE PRICES? PAGE 4 IS INTRODUCING GETTING SMART ABOUT SMART METERS ANSWER BOOK WHY ONTARIO IS INTRODUCING SMART METERS PAGE 2 WHAT ARE TIME-OF-USE PRICES? PAGE 4 HOW YOU CAN START TO PREPARE NOW PAGE 6 GETTING SMART ABOUT SMART METERS

More information

Building smart. communities.lendlease.com

Building smart. communities.lendlease.com Building smart communities.lendlease.com How to build a more efficient home You can build a home that s comfortable and economical to run. All it takes are a few smart ideas Good home design combined with

More information

1 General Description

1 General Description 1 General Description LED Tube Light adopts the new type LED as the light source, using the standard TB tube's end caps, makes it easy to install and replace the traditional fluorescent lamp. The TRF-51894

More information

CoolSpot. Unique Solutions for All-Indoor HVAC Projects

CoolSpot. Unique Solutions for All-Indoor HVAC Projects CoolSpot 1-3 Tons Cooling Capacity Ductless Ceiling Grid Self-Contained Air Conditioning Systems or split Systems Air-Cooled, Water-Cooled, Chilled Water or Magna Cool Precision Cooling Package Unique

More information

TOP TEN 2018 Energy Efficiency Technologies for the U.S. Building Sector

TOP TEN 2018 Energy Efficiency Technologies for the U.S. Building Sector TOP TEN 2018 Energy Efficiency Technologies for the U.S. Building Sector The U.S. Department of Energy (DOE) sponsored the Pacific Northwest National Laboratory (PNNL) to develop a Top Ten list to highlight

More information

PG&E s Applied Technology Services Hot Water Technology Performance Laboratory

PG&E s Applied Technology Services Hot Water Technology Performance Laboratory PG&E s Applied Technology Services Hot Water Technology Performance Laboratory Edwin Huestis, P.E. Senior Mechanical Engineer PG&E Applied Technology Services ACEEE Hot Water Forum February 23, 2016 Presentation

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

Electronic Pellet Burner Controller NPBC-V3-1

Electronic Pellet Burner Controller NPBC-V3-1 Electronic Pellet Burner Controller NPBC-V3- SOFTWARE VERSION 3.2/3. page of 3 CHANGES IN THE TECHNICAL AND USER GUIDE OR IN THE SOFTWARE VERSION Technical and User Guide's version Changes Page 2.8. The

More information