9.0 Systems For Domestic Water Installations

Size: px
Start display at page:

Download "9.0 Systems For Domestic Water Installations"

Transcription

1 9.0 Systems For Domestic Water Installations 9.0.1Equipment Catalogue Proportional Flow Dosing System For Liquid Dosing turbodos, DULCODOS metering systems protect pipework, fittings, and devices such as boilers, washing machines and dishwashers against corrosion and scale. Here, active substances such as silicate, phosphate or silicatephosphate mixtures are metered. These active substances form a protective layer in the pipework and reduce the corrosiveness and hardness deposits of the water: Silicate as corrosion inhibitor to prevent rust formation: "brownish water" in galvanised piping system, "pitting": needle-like holes in the piping. The applications include soft, corrosive waters with a high percentage of aggressive carbonic acid. The silicate acts to raise the ph value in the direction of the lime-carbonic acid equilibrium. Hydrolysis produces a silica gel which forms a thin protective layer in the pipework and fittings and thus prevents corrosion. Phosphate as ortho- and polyphosphate to prevent scale and corrosion in hard waters up to max. 20 CH (carbonate hardness). The hard-water salts such as calcium and magnesium ions responsible for scales are stabilised, i.e. these ions remain dissolved in the water and do not deposit as scale at the pipe walls. Overgrowing of the pipes is prevented and no scales deposit on the heating coils which dramatically reduce the efficiency. A thin, solid protective layer is formed. Mixtures containing silicate and phosphate for soft and medium-hard waters as corrosion and scale inhibitor. In order to maintain the protective layer, a continuous feed of the metering medium is required because otherwise this layer degrades within a few days. EXACTAPHOS The EXACTAPHOS metering solutions are matched to the metering output of the turbodos and DULCODOS systems. This guarantees that the percentages permissible according to the "German drinking water ordinance" of max. 40 mg/l SiO 2 silicate and/or 6.7 mg/l phosphate PO 4 (5 mg/l P 2 O 5 ) are complied with. Function of the systems The water flow causes the turbine meter or contact water meter to signal pulses with fixed pulse spacing corresponding to the flow rate to the metering pump. Each of these pulses result in a metering stroke of the metering pump, adding metering solution. The metering amount per stroke can be adjusted continuously between % using the stroke adjustment knob. Because of the very low response threshold and the short pulse spacing, a constant volume-proportional chemical metering is always maintained from minimum to maximum water flow rate and thus also guarantees the best process result. turbodos proportional flow metering system Consisting of a Beta metering pump, turbine meter, suction fitting with foot valve and 2-phase level switch with pre-alarm as protection against dry running und empty signal, metering valve and metering line. In the version "R" compact metering system, the metering pump is built onto the turbine meter. In the version "W" split metering system with wall bracket for mounting the metering pump. The turbine meter can be installed either vertically or horizontally. DULCODOS domestic Consisting of a ProMinent metering pump of the Beta series and gamma/ L with Pulse Control option for increasing or decreasing the incoming pulses, assembled on a stable, refillable metering tank with suction fitting and lockable screw cover as well as contact water meter. Manual or electronic agitators and further accessories can be installed. With the metering systems DULCODOS domestic, the specific metering output can be adapted to the individual requirements using the option Pulse Control, e.g. for chlorine metering in a domestic well water supply Equipment Catalogue

2 9.1 turbodos Proportional Flow Dosing Plant 9.1turboDOS Proportional Flow Dosing Plant turbodos Flow dosing system for adjustable chemical feed for the treatment of drinking water with chemicals such as EXACTAPHOS. Consisting of ProMinent Beta metering pump, flow meter, suction assembly with foot valve and float switch, dosing valve and discharge tubing. Version R ; compact dosing system. Dosing pump mounted horizontally onto flow meter (see fig. ). Version W ; split system with wall bracket for dosing pump. Pacing cable and 2 m PE discharge tubing. Optional flow meter mounting positions (see fig. pk_4_003). NG 10 R NG 10 W NG 20 R NG 20 W Flow meter connector* 1 1/4* 1 1/4* Connector thread G 1 1/2 A 1 1/2 A Length without thread mm Length with thread mm Response flow rate m 3 /h Lower operating limit m 3 /h Upper operating limit m 3 /h Dosing interval l Feed rate % ml/m Max. turbine operating pressure bar Max. dosing pump operating pressure bar Operating temperature C pressure loss at upper operating limit bar Flow rate at 0.2 bar pressure loss m 3 /h Electrical connection 230 V 50/60 Hz 230 V 50/60 Hz Power Uptake W Metering pump type BT4a 1602 PPE 2 BT4a 1005 PPE 2 * Connector width 1 1/4 with standard dimension threaded connector. Can be connected to smaller threaded connectors (see page 4). The threaded connector is not supplied as standard. pk_4_ Equipment Catalogue

3 9.1 turbodos Proportional Flow Dosing Plant turbodos Accessories Shipping weight kg NG 10 R compact dosing system NG 10 W split dosing system NG 20 R compact dosing system NG 20 W split dosing system Accessories not supplied as standard Threaded union set, brass with seal and 1 1/2" union nut. 2 connectors required. Flow meter connector DN 32 R 1 1/4 G 1 1/2 - (turbodos ) brass Flow meter connector DN 25 R 1 G 1 1/2 brass Flow meter connector DN 20 R 3/4 G 1 1/2 brass Materials Liquid end and valve polypropylene (PP) Dosing diaphragm EPDM with PTFE insert O-rings EPDM Valve balls ceramic Float switches PP Suction assembly flexible PVC Discharge tubing PE Flow meter housing brass Turbine PPE Shaft hard alloy Mounting sapphire pk_4_003 pk_1_ Equipment Catalogue

4 9.2 DULCODOS domestic Water Meter Controlled Dosing Plant 9.2DULCODOS domestic Water Meter Controlled Dosing Plant DULCODOS domestic Flow proportional flow dosing for potable and industrial water. Included in delivery: Contact water meter PN 16 - read-off - unions and seals. Metering tank made of transparent PE with litre scale and lockable screw cover constructed with ProMinent Beta and/or gamma/ L metering pump with Option Pulse Control for flow-proportional metering. With operating, advance warning and empty indication, mains leads with safety plug and 2 meter contact lead. Technical data Water treatment chemicals see chapter 7.4. Metering systems with Beta metering pump pk_4_004_1 Pump type Max. flow rate Max. pressure Tank size Connector width (KWM) Pulse rate Shipping weight m 3 /h bar l R l kg DN 10/16 BT4a1602NPB DN 10/ BT4a1602NPB DN 20/10 BT4a1005NPB / DN 20/ BT4a1005NPB / DN 30/10 BT4a1008NPB Max. temperature 45 C Electrical connection 230 V 10%, 50/60 Hz Feed rate ml/m Equipment Catalogue

5 9.2 DULCODOS domestic Water Meter Controlled Dosing Plant Metering systems with metering pump gamma/ L Pump type pk_4_004_2 Max. flow rate Max. pressure Tank size Connector width (KWM) Pulse rate Shipping weight m 3 /h bar l R l kg DN 10/16 GALa1602NPB DN 10/ GALa1602NPB DN 20/10 GALa1005NPB / DN 20/ GALa1005NPB / DN 30/10 GALa1008NPB Max. temperature 45 C Electrical connection V 10%, 50/60 Hz Feed rate ml/m 3, even higher concentrations possible at reduced flow Equipment Catalogue

Safe, precise and cost-effective dosing with ProMinent Low-pressure dosing pumps up to 1,000 l/h

Safe, precise and cost-effective dosing with ProMinent Low-pressure dosing pumps up to 1,000 l/h Safe, precise and cost-effective dosing with ProMinent Low-pressure dosing pumps up to 1,000 l/h Printed in Germany, PT PM 054 09/06 GB MT20 01 01/06 GB Solenoid and motor-driven diaphragm dosing pumps

More information

Operating Manual. Reverse Osmosis Water Purifier. MELAdem 55

Operating Manual. Reverse Osmosis Water Purifier. MELAdem 55 Operating Manual Reverse Osmosis Water Purifier MELAdem 55 Dear Doctor, Thank you for placing your trust in this reverse osmosis water purifier. Since 1951, MELAG has specialised in the production of sterilisation

More information

Technical information for installation and operation

Technical information for installation and operation Technical information for installation and operation PR 24002.65 12-04-2016 Subject to technical modifications LogoFresh 100 & 120 fresh water station Electronically controlled GB Meibes System-Technik

More information

TEMPLATE ASSISTED CRYSTALLIZATION. Presented By Ryan Lessing 11/13/2014

TEMPLATE ASSISTED CRYSTALLIZATION. Presented By Ryan Lessing 11/13/2014 TEMPLATE ASSISTED CRYSTALLIZATION Presented By Ryan Lessing 11/13/2014 Different Forms of Hardness in Water Calcium and Magnesium Bicarbonate- This is what is referred to as temporary hardness. Once it

More information

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz GRUNDFOS DATA BOOKLET UPS2 Circulator pumps 50/60 Hz UPS2 Table of contents 1. Product introduction 3 Type key.................................................................................... 3 Performance

More information

MONARCH SCALEOUT MONARCH WATER

MONARCH SCALEOUT MONARCH WATER MONARCH SCALEOUT MONARCH WATER ALTERNATIVE LIMESCALE PREVENTION WITH SOFT WATER BENEFITS With no salt, electricity or regeneration for the effective prevention of limescale 03/13SO MODEL SCALEOUT WATER

More information

2 OZONFILT And Bono Zon Ozone Plants

2 OZONFILT And Bono Zon Ozone Plants 2.3.1 OZONFILT Ozone Production Plants OZVa 1-4 (Operating Gas - Air) Under nominal conditions, the OZVa 1-4 range produces up to 40 g/h of ozone from oxygen in the surrounding air at a concentration of

More information

UP/UPS-B/UPN Hot Water Service Circulators

UP/UPS-B/UPN Hot Water Service Circulators UP/UPS-B/UPN Hot Water Service Circulators Visions & Values It is the Vision of the Company to achieve our Corporate Mission by providing quality and innovative products and services that give our customers

More information

Information on Feeder Systems ProMinent Australia

Information on Feeder Systems ProMinent Australia Information on Feeder Systems ProMinent Australia Powders that ProMinent have provided packages for: Sodium fluoride Sodium silicofluoride PAC Soda ash Lime Alum Potassium permanganate Calcium Hypochlorite

More information

AQUABION Galvanic water treatment for limescale & corrosion Frequently Asked Questions (FAQ s) June 2018

AQUABION Galvanic water treatment for limescale & corrosion Frequently Asked Questions (FAQ s) June 2018 AQUABION Galvanic water treatment for limescale & corrosion Frequently Asked Questions (FAQ s) June 2018 Q 1: What is AQUABION? A: AQUABION is a treatment for limescale in water systems consisting of a

More information

ph Measuring System Start-up and maintenance manual e Contents

ph Measuring System Start-up and maintenance manual e Contents Contents 1. Starting up 1.1 Scope of delivery: 1.2 Reconditioning 1.3 Installing the ph probe 1.4 Installing the switch cabinet 1.5 Filling the electrolyte reservoir 1.6 Installing the reference electrode

More information

Suction Controller SDR

Suction Controller SDR MB 00 / Constant suction pressure and leakage stop The suction controllers SDR 0 and SDR 00 have been developed because the flow rate of diaphragm metering pumps can be affected - among other factors -

More information

Valves, controls + systems. Local and district heating technology. Innovation + Quality. Product range. for improved.

Valves, controls + systems. Local and district heating technology. Innovation + Quality. Product range. for improved. Innovation + Quality Valves, controls + systems Local and district heating technology for improved energy efficiency Product range Local and district heating technology The term Local and district heating

More information

Chemical Pumps Vertical Chemical Pump Type TNP

Chemical Pumps Vertical Chemical Pump Type TNP Chemical Pumps Vertical Chemical Pump Type TNP In PP / PE-UHMW / PVDF Vertical setting depths up to 00 mm Applications Type TNP vertical chemical pumps are specifically designed to handle acids, alkalis

More information

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz GRUNDFOS DATA BOOKLET Circulator pumps 50/60 Hz 2 Product range 2. Product range UP(S) COMFORT, 50/60 Hz Pump type 24-hour timer Supplied with Dimensions Accessories Data sheet Thermostat Isolating valve

More information

Hand pump JP-02. Hand pump JP-02 for acids, alkalies and water-based chemicals. depending on lever position. The telescopic suction tube is adjustable

Hand pump JP-02. Hand pump JP-02 for acids, alkalies and water-based chemicals. depending on lever position. The telescopic suction tube is adjustable Hand pump JP-02 Hand pump JP-02 for acids, alkalies and water-based chemicals Shaft: Stainless steel 316 Ti Seals: Viton Flow rate: 0,3, 0,37 or 0,45 l/stroke* depending on lever position from 340 to 900

More information

4.Metering Pumps CONSTRUCTIONS. CR-N Series CRA-N Series: servo control model. CRP-N Series

4.Metering Pumps CONSTRUCTIONS. CR-N Series CRA-N Series: servo control model. CRP-N Series 4.Metering Pumps ELEPON FEEDER CR-N and CRM Series are designed as the direct-motion diaphragm injection pumps as safe and multipurpose pumps and also low-cast pumps. These pumps are used as the injection

More information

Oxiperm C 164 Fully automatic chlorine dioxide processing plant C, -6000C, -7500C, C. Service manual. Oxiperm 164C 4-10 kg Service en

Oxiperm C 164 Fully automatic chlorine dioxide processing plant C, -6000C, -7500C, C. Service manual. Oxiperm 164C 4-10 kg Service en Oxiperm 164C 4-10 kg Service en Oxiperm C 164 Fully automatic chlorine dioxide processing plant 164-4000C, -6000C, -7500C, -10000C Service manual 15.710138-V2.0 1 Imprint Oxiperm C 164 Fully automatic

More information

.2 Section Waste Management and Disposal..5 Section Cleaning and Startup of Mechanical Piping Systems.

.2 Section Waste Management and Disposal..5 Section Cleaning and Startup of Mechanical Piping Systems. Issued 2006/08/01 Section 15188 HVAC Water Treatment Systems Page 1 of 14 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3 Section

More information

Sentinel KalGUARD. Product Facts. Water Treatment Equipment to Manage Hard Water Limescale. Features & Benefits. Overview

Sentinel KalGUARD. Product Facts. Water Treatment Equipment to Manage Hard Water Limescale. Features & Benefits. Overview Sentinel KalGUARD Water Treatment Equipment to Manage Hard Water Limescale Features & Benefits Provides whole system protection: Provides protection to water heaters Taps, showers and valves free of lime

More information

HDC Standard. Stationary high-pressure cleaner for the simultaneous use of 2 to 8 take-off points. Modular design. Intelligent pump control

HDC Standard. Stationary high-pressure cleaner for the simultaneous use of 2 to 8 take-off points. Modular design. Intelligent pump control HDC Standard Stationary high-pressure cleaner for the simultaneous use of 2 to 8 take-off points 1 Modular design The HDC systems can be equipped with up to 4 pumps depending on the requirements. This

More information

Installer & User Guide Effective February 2013

Installer & User Guide Effective February 2013 Model No. MONARCH WATER Installer & User Guide Effective February 2013 For Monarch Scaleout Suppliers to H.M. the Queens Estate at Sandringham Monarch Water Ltd. Halesworth Road Bramfield IP19 9HP T 01986

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Data sheet Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 IHPT The XB is a brazed plate heat exchanger designed for use with district heating systems

More information

Brawa-Mix Thermostatic mixing valves

Brawa-Mix Thermostatic mixing valves Technical information Tender specification: The Oventrop thermostatic mixing valve Brawa-Mix without dead zone mixes hot and cold water according to an infinitely adjustable water temperature. The thermostatic

More information

FULL RANGE of products for the protection of boilers and water heating loops SLUDGE FILTERS FDM-1P / FDM-2 / FDM-3

FULL RANGE of products for the protection of boilers and water heating loops SLUDGE FILTERS FDM-1P / FDM-2 / FDM-3 FULL RANGE of products for the protection of boilers and water heating loops SLUDGE FILTERS FDM-1P / FDM-2 / FDM-3 ACID CONDENSATE NEUTRALISERS NEUTRAL COND / NEUTRAL MINI FDM SLUDGE FILTERS The FDM sludge

More information

Operating instructions

Operating instructions Operating instructions This handbook assumes that the reader and/ or operator is competent in the operation of chemical dosing systems and fully understands the inherent risks associated with the handling

More information

Concise catalogue Water-Industry

Concise catalogue Water-Industry 2008 Concise catalogue Water-Industry One-channel instruments to measure ph, EC, DO and free chlorine, panel and wall-mounting version. Transmitters - controllers very easy to utilize, the customer does

More information

ProMinent ProMus Hydraulic Diaphragm Metering Pumps

ProMinent ProMus Hydraulic Diaphragm Metering Pumps ProMinent ProMus ProMinent ProMus Description: The ProMus is a motor driven metering pump with a hydraulically actuated diaphragm. The drive case and the hydraulic unit are filled with a liquid that functions

More information

PowerPoint Presentation by: Associated Technical Authors. Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois

PowerPoint Presentation by: Associated Technical Authors. Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois Althouse Turnquist Bracciano PowerPoint Presentation by: Associated Technical Authors Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois Chapter 5 Explain the purpose and operation of

More information

Polymer Dilution Blend and Feed Specifications For General Use

Polymer Dilution Blend and Feed Specifications For General Use Polymer Dilution Blend and Feed Specifications For General Use Electronic Diaphragm Metering Pump 1.0 GENERAL The contractor shall furnish and install polymer dilution blending and feeding units together

More information

Case Study and 700 HP Steam Boilers - Scale

Case Study and 700 HP Steam Boilers - Scale Case Study - 600 and 700 HP Steam Boilers - Scale Case study updated on June 10, 2013 Installer: MBI Water Solutions - HydroFLOW Master Distributor in the US Pacific Northwest. Customer: Chemical Plant

More information

Signal anodes and sacrificial anodes. Rainwater harvesting. Domestic water system centre. Water filters

Signal anodes and sacrificial anodes. Rainwater harvesting. Domestic water system centre. Water filters Signal anodes and sacrificial anodes Rainwater harvesting Domestic water system centre Water filters CHAPTER Equipment for drinking water supply and rainwater harvesting OVERVIEW Equipment for drinking

More information

RECOMMENDATIONS FOR INSTALLATION

RECOMMENDATIONS FOR INSTALLATION PHYSICAL TREATMENT DEVICES RECOMMENDATIONS FOR INSTALLATION POWEL s.r.o., Moyzesova 43, 080 01 Presov, Slovak republic, EU tel./fax: +421 51 7562171, e-mail: powel@powel.sk, www.powel.sk CONTENTS Page

More information

Priming Aids ASH and AHP

Priming Aids ASH and AHP MB 1 33 01 / 1 What happens during priming? All types of metering pumps with low flow rates per stroke often haven priming problems which grow as the suction lift and the liquid density increase. Low flow

More information

BOILER SYSTEM CHEMICAL TREATMENT 101

BOILER SYSTEM CHEMICAL TREATMENT 101 BOILER SYSTEM CHEMICAL TREATMENT 101 The primary function of a boiler is to transfer heat from hot gases generated by the combustion of fuel into water until it becomes hot or turns to steam. The steam

More information

Fibreglass reinforced polyester (FRP) water collection basin with sloping base and smooth internal finish with rounded corners for easy cleaning.

Fibreglass reinforced polyester (FRP) water collection basin with sloping base and smooth internal finish with rounded corners for easy cleaning. 1 3 2 4 5 Closed Circuit Cooling Tower Factory Assembled - Modular Compact Design 1 IP56 Motor(s) directly coupled to low energy and high efficient fan(s) 2 Fibreglass reinforced polyester (FRP) sandwich

More information

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function Solar storage-to-boiler thermostatic connection kit 6-63 series REGI STERED BS EN ISO 900:000 Cert. n FM 64 UNI EN ISO 900:000 Cert. n 0003 CLEFFI 064/09 GB Function The solar storage-to-boiler connection

More information

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS W GE R MAN Y W GE R MAN Y V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS Design Angle left Straight W GE R MAN Y Angle right The Therafix

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 The XB is a brazed plate heat exchanger designed for use with district heating systems (i.e. air conditioning,

More information

Akiki Engineering Est.

Akiki Engineering Est. Akiki Engineering Est. Water & Steam Experts 4.1. Closed System Catalogue October 7, 2010 Contents Chemical Products for Closed Systems......................... 3 Equipment For Closed Systems (1)...........................

More information

Genesis Whole House Chlorination System Page 2

Genesis Whole House Chlorination System Page 2 Genesis Whole House Chlorination System Page 2 Genesis Whole House Chlorination System Page 3 Table of Contents Performance Data and System Specifications................................ 4 Unpacking and

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Data sheet Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 IHPT The XB is a brazed plate heat exchanger designed for use with district heating systems

More information

Glass and Dishwashers AMX / AUX Series

Glass and Dishwashers AMX / AUX Series Glass and Dishwashers AMX / AUX Series INSTALLATION OPERATION REV. 8.xx 04.07.2005 Installation and Operation Instructions for Models of AMX / AUX Series Content Page 1 Installation... 3 2 Connections...

More information

GRUNDFOS ALLDOS DISINFECTION. ALLDOS DISINFECTION SYSTEMS with Chlorine Gas 1 GRUNDFOS ALLDOS DISINFECTION

GRUNDFOS ALLDOS DISINFECTION. ALLDOS DISINFECTION SYSTEMS with Chlorine Gas 1 GRUNDFOS ALLDOS DISINFECTION GRUNDFOS ALLDOS DISINFECTION ALLDOS DISINFECTION SYSTEMS with Chlorine Gas 1 GRUNDFOS ALLDOS DISINFECTION Content Applications 4-5 Page Geco 103-100 compact dosing unit 1 Vacuum regulator and dosing unit

More information

The sealless FLUX F 424

The sealless FLUX F 424 The sealless FLUX F The liquids to be pumped are abrasive, but they do not leave any deposits. Dry running of the pump must not cause any problems. You are looking for a lightweight, general purpose pump

More information

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL Essex County College - West Essex Campus Addition And Renovations dib # 54292 / 11-14 SECTION 232116 - HYDRONIC PIPING SPECIALTIES PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions

More information

The NEW advanced electrolytic scale inhibitor with intelligent LED monitoring technology from Sentinel

The NEW advanced electrolytic scale inhibitor with intelligent LED monitoring technology from Sentinel The NEW advanced electrolytic scale inhibitor with intelligent LED monitoring technology from Sentinel 1. Proven best in class scale control 2. Unique LED shows ScalePro is working effectively 3. One installation

More information

Wall-hung boilers. Spare parts catalogue. ecotec plus

Wall-hung boilers. Spare parts catalogue. ecotec plus Spare parts catalogue Wall-hung boilers ecotec plus VU 126/6-5 OV (plus 412) VU 156/6-5 OV (plus 415) VU 186/6-5 OV (plus 418) VU 246/6-5 OV (plus 424) 0020223106_01 GB 10/2015 Content General view of

More information

Proportioners for Stationary Extinguishing Systems

Proportioners for Stationary Extinguishing Systems Proportioners and Monitors for Fire-Fighting FireDos Proportioners for Stationary Extinguishing Systems Deluge systems Seawater extinguishing systems Sprinkler systems Foam extinguishing systems About

More information

1 What is the name of the tool shown in the diagram? Basin wrench Footprint wrench Stilson wrench Torque wrench.

1 What is the name of the tool shown in the diagram? Basin wrench Footprint wrench Stilson wrench Torque wrench. 36 Exam Success Plumbing and Heating 6189-11 and 6189-21 Sample test The sample test below is for paper 6189-005, Understand and carry out site preparation, and pipework fabrication techniques for domestic

More information

PUROTAP easy. Installation Function Operation Service. fast efficient safe. Demineralised heating water perfect for every system

PUROTAP easy. Installation Function Operation Service. fast efficient safe. Demineralised heating water perfect for every system EN Demineralised heating water perfect for every system PUROTAP easy Installation Function Operation Service fast efficient safe Minerals and salts in technical water circulations lead to corrosion and

More information

Installation and operating instructions. DK energy storage and DK energy buffer

Installation and operating instructions. DK energy storage and DK energy buffer Installation and operating instructions DK energy storage and DK energy buffer Edition: 08-2015 1 Preliminary note With this DK energy storage / DK energy buffer you purchased a DK quality product. The

More information

Akva Vita Instantaneous water heater

Akva Vita Instantaneous water heater Akva Vita Instantaneous water heater Akva Vita Table of Contents Akva Vita... 1 Table of Contents... 1 Safety notes... 2 Delivery... 2 Transport and storage... 2 Mounting... 3 Pipes connections... 4 Electrical

More information

Spectrum TM. Installation, Service & Operation Manual O FLO. SoftH 2. Water Softener. Table of Contents

Spectrum TM. Installation, Service & Operation Manual O FLO. SoftH 2. Water Softener. Table of Contents Installation, Service & Operation Manual SoftH 2 O FLO Water Softener Table of Contents 1. Description & Equipment Adjustments p.2 2. Components, Features & Functions p.3 3. Valve User Interface p.4 4.

More information

TECHNICAL MANUAL ASGX

TECHNICAL MANUAL ASGX TECHNICAL MANUAL ASGX MEDIUM/HIGH PRESSURE HOT WATER BOILER INDEX 1 TECHNICAL CHARACTERISTICS... 2 1.1 GENERAL... 2 1.2 TECHNICAL DATA... 2 2 ACCESSORIES... 3 2.1 PRESSURE... 3 Pressure gauge... 3 Operation

More information

Cold water HD 9/18-4 ST

Cold water HD 9/18-4 ST Cold water HD 9/18-4 ST The space-saving stationary high-pressure cleaners from Kärcher with up to 6 supply points can be individually configured according to requirements and impress with low wear and

More information

Pipe: ASTM B88, hard drawn copper, Type K. Fittings: ASTM B16.22 Wrought copper and copper alloy.

Pipe: ASTM B88, hard drawn copper, Type K. Fittings: ASTM B16.22 Wrought copper and copper alloy. Design Standard Hydronic Piping in Buildings Detailed specifications follow. PART 1 - GENERAL 1.01 Above ground hydronic piping 2 inches and less in diameter shall be as follows: Copper PEX-A Pipe: ASTM

More information

TS RD 7761 RD, 7761 RD

TS RD 7761 RD, 7761 RD 1/2 HERZ Calis TS RD three way valve HERZ Calis TS RD 100% three-way valve for heating and cooling Datasheet for 1 7761 RD, Issue 0716 Dimensions in mm Order number Dimension R A B C kvs dp (bar) maximum

More information

SuperStor Glass Lined Storage Tank

SuperStor Glass Lined Storage Tank SuperStor Glass Lined Storage Tank INSTALLATION MAINTENANCE TROUBLESHOOTING PARTS Storage Tank Models GL-50 / GL-80* GL-119* / GL-175* For Residential and Commercial Use *Available in Metal Jacketed ASME

More information

Descaler & Prevention

Descaler & Prevention Descaler & Prevention Treatment Method for existing scaled surfaces like inside of piping, tubes, Heaters, boilers, sump wall etc. By Deepak Chopra Watch Water GmbH Fahrlachstraße 14 68165 Mannheim Germany

More information

Let s talk about wa. Filtering, water softening, semi demineralisation or full demineralisation are the options open.

Let s talk about wa. Filtering, water softening, semi demineralisation or full demineralisation are the options open. Water treatment Let s talk about wa Today s catering industry aims to present its customers with quality and style. In one word: perfection. Meticulously clean, sparkling crockery is vital to this perfection

More information

Scale Stopper Plus Installation & Start-Up Guide

Scale Stopper Plus Installation & Start-Up Guide Clean Water Made Easy www.cleanwaterstore.com Scale Stopper Plus Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your

More information

521 Series. MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions

521 Series.  MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions MixCal adjustable three-way thermostatic mixing valve 37. www.caleffi.com Copyright 15 Caleffi 51 Series Installation, commissioning and service instructions Function The Caleffi MixCal three-way thermostatic

More information

Air operated diaphragm pumps. Catalogue 2011 rev 1

Air operated diaphragm pumps. Catalogue 2011 rev 1 Air operated diaphragm pumps Catalogue 2011 rev 1 General your reliable pumpchoice With experience from industrial fluid handling and pump manufacture since 1970, we know what you as a customer require

More information

HD 6/13 C. Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle. 3 Accessory storage

HD 6/13 C. Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle. 3 Accessory storage HD 6/13 C Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle. 2 1 Mobility The integrated carrying handle on the front of the machine enable

More information

Installation Instructions

Installation Instructions Installation Instructions The energy you need Accessories/PFGHRD 60/100 Passive Flue Gas Heat Recovery Device Explanation of Symbols a DANGER: Risk of injuries. The PFGHRD is an integral part of the flue

More information

AUTOMATIC FILTERS. AG series HECTRON

AUTOMATIC FILTERS. AG series HECTRON AUTOMATIC FILTERS AG series HECTRON Automatic self-cleaning filters - AG series Equipped with a high-precision woven fabric filter screen, these automatic self-cleaning filters produce optimum quality

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION WATER TREATMENT

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION WATER TREATMENT PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Open Cooling Towers: a treatment system utilizing chemicals and biocides that contain no heavy metals and are non-carconigenic to prevent corrosion,

More information

=Classic range= Classic range technologies. Magnesium anode. Sheathed heating element

=Classic range= Classic range technologies. Magnesium anode. Sheathed heating element =Classic range= Classic range technologies Magnesium anode The magnesium anode is located in the centre of the enamelled tank and provides excellent protection against corrosion; this anode is consumed

More information

Partner Valve/High Quality Ball Valve LENO MSV-S

Partner Valve/High Quality Ball Valve LENO MSV-S Partner Valve/High Quality Ball Valve LENO MSV-S Description LENO MSV-S is a partner valve for all manual balancing valves in the LENO family. LENO MSV- S can also be applied as a high quality ball valve.

More information

Water Purification 85

Water Purification 85 Water Purification 85 Distillation Distillation is a natural process that has been used to purify liquids for many hundreds of years. Today it remains the most commonly used technique for water purification

More information

Please take time to carefully read through these guidelines before using your Kamco pump.

Please take time to carefully read through these guidelines before using your Kamco pump. The Kamco CLEARFLOW CF90 : QUANTUM pump is a purpose built unit for Power Flushing central heating systems, designed to cure circulation and boiler noise problems caused by the accumulation of sludge,

More information

Water Purification. Quality distilled... the most reliable method of purifying water 81

Water Purification. Quality distilled... the most reliable method of purifying water 81 Water Purification Quality distilled... the most reliable method of purifying water 81 Distillation Distillation is a natural process that has been used to purify liquids for many hundreds of years. Today

More information

Akva Vita TDP District heating flat station for direct heating and domestic hot water systems

Akva Vita TDP District heating flat station for direct heating and domestic hot water systems Akva Vita TDP District heating flat station for direct heating and domestic hot water systems Akva Vita TDP Table of contents Akva Vita TDP... 1 Table of contents... 1 Safety notes... 2 Delivery... 2 Transport

More information

Boiler Additives And Filtration

Boiler Additives And Filtration 25/08/17 B23-1A Boiler & Hydronic System Additives Product Description Boiler Water Side Cleaner, 1L CLEAN BOILER Boiler Combustion Side Cleaner, 1L CLEAN F9 A Boiler Combustion Side Cleaner, 1L CLEAN

More information

WATER FILTRATION SYSTEM (USF3) OWNER S MANUAL

WATER FILTRATION SYSTEM (USF3) OWNER S MANUAL WATER FILTRATION SYSTEM (USF3) OWNER S MANUAL 1 INTRODUCTION Congratulations on choosing Permatech to improve the quality of your water. You will immediately begin to notice the numerous benefits of having

More information

Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems

Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems Akva Vita TDP-F Table of contents Akva Vita TDP-F...1 Table of contents...1 Safety notes...2 Delivery...2

More information

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT Refrigerating Desiccant High polymer membrane dryer VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT JIS symbol Air filter Auto. drain (Module unit) (Separate) Compact Precise (Related

More information

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Reduced Installation time Precision regulation Minimal tooling required 100% tested prior to packaging High quality

More information

Quick Start Guide LIQ-QSG-Hx338, Rev M July Rosemount Hx338. Steam Sterilizable and Autoclavable ph Sensor

Quick Start Guide LIQ-QSG-Hx338, Rev M July Rosemount Hx338. Steam Sterilizable and Autoclavable ph Sensor Quick Start Guide LIQ-QSG-Hx338, Rev M July 2017 Rosemount Hx338 Steam Sterilizable and Autoclavable ph Sensor Safety Information WARNING! Do not exceed temperature and pressure limitations of 266 F (130

More information

FTM-L SERIES SINGLE OR TWIN DIRECT STEAM MIXER KETTLE COMPLETE WITH HYDRAULIC POWER TILT BRIDGE INSTALLATION - OPERATION - MAINTENANCE

FTM-L SERIES SINGLE OR TWIN DIRECT STEAM MIXER KETTLE COMPLETE WITH HYDRAULIC POWER TILT BRIDGE INSTALLATION - OPERATION - MAINTENANCE FTM-L ERIE INGLE OR TWIN DIRECT TEAM MIXER KETTLE COMPLETE WITH HYDRAULIC POWER TILT BRIDGE INTALLATION - OPERATION - MAINTENANCE INGLE MODEL FTM-40L FTM-60L FTM-80L FTM-100L TWIN MODEL FTM-(2)40L FTM-(2)60L

More information

PORTABLE HYDRANT PN10 1A; 2A; 1B; 2B; 1C; 2C TYPES

PORTABLE HYDRANT PN10 1A; 2A; 1B; 2B; 1C; 2C TYPES PORTABLE HYDRANT PN1 1A; 2A; 1B; 2B; 1C; 2C TYPES HP 1 page 1A (type 1) (type 2) In water supply systems for fire extinguishing or other necessities. - Design... in conformity with STAS 698; - Nominal

More information

Mikrotherm. Manual Radiator Valves With presetting

Mikrotherm. Manual Radiator Valves With presetting Mikrotherm Manual Radiator Valves With presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Mikrotherm Mikrotherm The Mikrotherm manual radiator valve is used in warm water pump heating systems,

More information

AQUACALK EQUIPMENT. Description of the problem:

AQUACALK EQUIPMENT. Description of the problem: AQUACALK EQUIPMENT Description of the problem: The input water contained hardness of water (ions of calcium and magnesium dissolved in water) has a tendency for the extraction of undissolved compounds

More information

Operating instructions

Operating instructions Operating instructions (Translation of the original operating instructions) Type TEKA FILTERCUBE-MV TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen

More information

Self-supporting hot water high pressure cleaner on trailer Designed for Weed Control WeedMaster TM 221

Self-supporting hot water high pressure cleaner on trailer Designed for Weed Control WeedMaster TM 221 Self-supporting hot water high pressure cleaner on trailer Designed for Weed Control WeedMaster TM 221 High pressure system mounted in a Waterkracht single-axle trailer, complete with surge brake and mudguards.

More information

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP WWPPCHLFT260 Instructions WWPPCHLFT260_Horizontal Multistage Centrifugal Pump_IB.indd 1 READ THIS MANUAL CAREFULL BEFORE INSTALL, START THE PUMP 1. Suction 2. Plug

More information

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 0 l capacity Datasheet Part no. and prices: see pricelist VITOCELL 300-V Type EVA and EVI Vertical DHW cylinder made from stainless steel 5/2012 Product

More information

HX-30/40 and HX-30/40 S Glass and Dishwashers

HX-30/40 and HX-30/40 S Glass and Dishwashers HX-30/40 and HX-30/40 S Glass and Dishwashers INSTALLATION OPERATION VERSION 18/01/00 2 Installation and Operation Instructions for Model HX-30/40 and HX-30/40 S (with built-in softener) Content Page 1

More information

Fluoride. by ProMinent May 2016

Fluoride. by ProMinent May 2016 Fluoride by ProMinent May 2016 ProMinent Australia Head Office - Sydney Unit 4, 4 Narabang Way BELROSE NSW 2085 PO Box 85, BELROSE WEST NSW 2085 Ph: (02) 9450 0995 Fax: (02) 9450 0996 Fax (02) 9450 0994

More information

CERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours.

CERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours. CERAMIC PUMPS FGP Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours. FGP THE SOPHISTICATED PUMP CONCEPT If you want to solve demanding pumping tasks in the industry

More information

Installation and Operation Instructions K36E Modular Heating Circuit - DN 25 Boiler charging set

Installation and Operation Instructions K36E Modular Heating Circuit - DN 25 Boiler charging set PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 Email: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions K36E Modular Heating

More information

J-PRO-22 Pump Proportional Feed Chlorinator Installation & Start-Up Guide

J-PRO-22 Pump Proportional Feed Chlorinator Installation & Start-Up Guide J-PRO-22 Pump Proportional Feed Chlorinator Installation & Start-Up Guide Thank you for purchasing a Clean Water System! Please review this start-up guide entirely before beginning to install your system

More information

HD 5/12 C Plus. Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle.

HD 5/12 C Plus. Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle. HD 5/12 C Plus Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle. 1 Mobility 3 Accessory storage The integrated carrying handle on the

More information

Action shower Fog Rain

Action shower Fog Rain Operation manual fog shower (W2-06/07) Seite 1 von 8 Action shower Fog Rain Table of contents 1.Technical description... 1 2. Function... 2 3. Installation... 4 4. Taking into operation... 5 5. Maintenance...

More information

Hot water compact class HDS 5/12 C *AU

Hot water compact class HDS 5/12 C *AU Hot water compact class HDS 5/12 C *AU Standard accessories: Spray gun Extended, Easy Press Spray gun with Softgrip insert High-pressure hose 10 m Spray pipe 550 mm Power nozzle SDS system Anti-twist system

More information

HD 5/12 C + Mobility. Accessory storage

HD 5/12 C + Mobility. Accessory storage HD 5/12 C + A new compact commercial machine for extended use. With its compact dimensions, robust construction and fantastic manoeuvrability, this unit is a credit to the compact class. 1 Mobility 3 Accessory

More information

Thermostatic mixing valves with interchangeable cartridges

Thermostatic mixing valves with interchangeable cartridges www.caleffi.com R37. Thermostatic mixing valves with interchangeable cartridges Installation, commissioning and servicing instructions 3 Series Function The thermostatic mixing valve is used in systems

More information

PrimusCenter DWC7000. Domestic Water Centre. Product specification sheet

PrimusCenter DWC7000. Domestic Water Centre. Product specification sheet PrimusCenter DWC7000 Domestic Water Centre Product specification sheet Construction The domestic water centre consists of: R1 filter connection fitting with backflow preventer FK7000 filter combination

More information

Electronic Water Treatment Systems. Environmental Protective Technology

Electronic Water Treatment Systems. Environmental Protective Technology Electronic Water Treatment Systems No salt No magnetic field No chemicals No maintenance Environmental Protective Technology Introduction We are a manufacturers of water treatment devices for the world

More information