Test Report for the determination of Critical Fall Height for Under Playground Surfacing with Plants

Size: px
Start display at page:

Download "Test Report for the determination of Critical Fall Height for Under Playground Surfacing with Plants"

Transcription

1 Page: 1 of 6 ABN /109A Bonds Rd Punchbowl NSW 2196 Test Report for the determination of Critical Fall Height for Under Playground Surfacing with Plants Specification: Australian Standard AS/NZS4422:1996 Amdt 1 Playground surfacing Specifications, requirements and test method Client: Contact: OZ Breed 14 Cupitts Lane Clarendon NSW 2756 Katrina Layt Date of Test: 15 August Location of test 14 Cupitts Lane Clarendon NSW 2756 Date of Report: Report Number: 2956 Acousto-Scan is an Accredited ISO/IEC NATA Laboratory and IS Quality Company Date 30 Aug Laboratory Director Grant Humphreys This report contains 6 pages The report may not be reproduced except in full without the written approval of the Laboratory.

2 Page: 2 of 6 Material Identification: Under Playground Surfacing The product comprised of 1. Playbark Area A Mulch mm bark chips with plants 2. Port Stephens Pine Area B Mulch mm bark chips and with ` plants Archiving: None Dates of test: 15 Aug Location of Testing: OZbreed 14 Cupitts Lane Clarendon NSW 2756SW 2196, Australia Temperature (surface): Dry test 17 C Testing to: Australian test method AS/NZS4422:1996 Amdt 1 The prepared samples of material were tested in accordance with Australian test method AS/NZS4422:1996 Amdt 1. This method involves impacting the material with an instrumented head-form and measuring the deceleration of the head-form on impact. Two impact parameters are determined from the recorded acceleration-time relationship - the Head Injury Criterion (HIC) and the maximum deceleration produced (G-max). HIC is a measure of the severity of the impact and takes into account the time duration of the impact as well as its magnitude. It is defined in the Standard by the following integral formula: t2 HIC ( t t ) ( ) a. dt 2 1 t2 t1 t 1 max where t 1 and t 2 are times between the starting and finishing times of the impact chosen to maximise the function, and a is the instantaneous value of deceleration during the impact measured in g, the acceleration due to gravity. The critical fall height (CFH) for a particular surfacing material is the lowest drop height of the head-form, which produces an HIC of 1000 and a G-max of 200 G, whichever is the lower. These threshold values, which determine the critical fall height, are set in regard to minimising head injuries resulting from an impact of a human head with a surface. Thus, the greater the critical fall height, the safer is the surfacing material. This critical fall height can be referenced to the platform heights of particular items of playground equipment installed in playgrounds from which children might fall. The fall height has been calculated relative to the nominated piece of equipment, and that no assumption has been made about the height of the user above that equipment.

3 Page: 3 of 6 Test equipment: The following test equipment conforming AS/NZS4422:1996 Amdt 1 was used. Head-form: Equipment: Aluminium alloy head-form #, AS0005 ISO Size J, mass 5.0 kg Uniaxe-II impact tester #AS0019 Calibration factor: 4 mv/g (g = m/s/s) Drop method: Timing: guiding rails infra-red gates Errors and Uncertainties: The Standard AS/NZS4422:1996 Amdt 1 Appendix A calls for an expression of critical fall height rounded down to the nearest 0.1 m. Uncertainties were calculated in accordance with the ISO Guide to the Expression of Uncertainty in Measurement ISO/IEC GUIDE 98-3:2010 Uncertainty Confidence Level = 95%: Coverage Factor k=2 Procedure: Two types of bark mulch where tested for impact attenuation to Australian Standard AS/NZS4422:1996 Amdt 1 Playground surfacing Specifications, requirements and test method. The testing was carried out in accordance with Acousto-Scan s Work Instruction L4_09_05 All equipment was in calibration and traceable to national Standards. The maximum G-max and HIC where recorded and later entered into the processing sheet. Fig1: Layout of positions

4 Page: 4 of 6 Results Test Date Test Material Test Conditions Critical Fall Height Material Allowance 1 Pine Mulch (Mulch 2)-M3 Indentation 5.9 m 60mm 2 Pine Mulch (Mulch 2) Dead Tanika 6.2 m 60mm 3 On Soil outside test area 1.4 m 20mm 4 Pine Mulch (Mulch 2) On Naringa plant 5.9 m 60mm 5 Playbark (Mulch 1) On Tanika with soil 6.2 m 60mm 6 Playbark (Mulch 1) On Tanika without soil 4.4 m 60mm 7 Playbark (Mulch 1). 3.2 m 60mm 9 Playbark (Mulch 1).-Dead Tanika 3.2 m 60mm 10 Soil outside test area 1.8m 20mm The Australian Standard AS/NZS4422:1996 Amdt 1 details the usage of impact absorbing materials in children s playgrounds and defines relevant terms and conditions. The fall height has been calculated relative to the nominated piece of equipment, and that no assumption has been made about the height of the user above that equipment. Loose fill material should be installed to the depth shown in the test report, which should be not less than 200 mm. And because it will deteriorate during use, an additional depth (the material allowance) should be laid. In high traffic areas, such as under swings and slippery dips, an additional 20% in depth is recommended.

5 Page: 5 of 6 Photo 1: Pine Mulch (Mulch 2)-M3 Indentation Photo 2 Pine Mulch (Mulch 2) Dead Tanika Photo 3: On Soil Photo 4 Pine Mulch (Mulch 2)- On Naringa plant with soil Photo 5 Playbark On Tanika with soil Photo 6 Playbark- On Tanika without soil

6 Page: 6 of 6 Photo 7 Playbark Photo 8 Playbark- Dead Tanika Photo 9 On Soil Photo 10 Pine Mulch (Mulch 2) Comments: Two types of bark mulch where tested for impact attenuation to Australian Standard AS/NZS4422:1996 Amdt 1 Playground surfacing Specifications, requirements and test method. It was observed that there were no hard areas due to roots or root matting. The dead plant root ball was small and when impacted on, the CFH was 3.2m The CFH minimum for the two complete areas was 3.2m.

Test Report to AS/NZS :2015. Report No. T160402_S

Test Report to AS/NZS :2015. Report No. T160402_S Page 1 of 6 EMC Technologies Pty Ltd ABN 82 057 105 549 Unit 3/87 Station Road Seven Hills NSW 2147 Australia Telephone +61 2 9624 2777 Facsimile +61 2 9838 4050 Email sales@emctech.com.au Test Report

More information

Information and Installation Guide

Information and Installation Guide Information and Installation Guide Living Soft Fall allows turf to be used in fall zones of playgrounds safely and to the Australian Standards. ^ Turf being used at a playground without Living Soft Fall

More information

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in INFRASTRUCTURE TECHNOLOGIES Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in accordance with AS/NZS 3837:1998 Fire Testing Report Author: Heherson Alarde Report Number:

More information

Classification of Fire Performance of Wall and Ceiling Lining Materials

Classification of Fire Performance of Wall and Ceiling Lining Materials Classification of Fire Performance of Wall and Ceiling Lining Materials Using the Method of Kokkala, Thomas and Karlsson Reference: Kokkala, M.A. Thomas, P.H. and Karlsson, B. Rate of Heat Release and

More information

CALIBRATION HOW IT WORKS

CALIBRATION HOW IT WORKS HIGH POWER SOLUTIONS POWER DETECTORS ENERGY DETECTORS At Gentec-EO, we understand that the essence of our business since over 45 years has been delivering accuracy. There are no half measures: it either

More information

Vibration tests on a TNAML Luminaire

Vibration tests on a TNAML Luminaire Sebert Trillingstechniek B.V. Report M13.001-P13.001 rev.01 Date 26 august 2013 Vibration tests on a TNAML Luminaire Client Technor Benelux B.V. Veersteeg 15 4212 LR Spijk The Netherlands Contact Person

More information

CALIBRATION HOW IT WORKS

CALIBRATION HOW IT WORKS THZ DETECTORS PHOTO DETECTORS HIGH POWER DETECTORS POWER DETECTORS ENERGY DETECTORS MONITORS At Gentec-EO, we understand that the essence of our business since 40 years has been delivering accuracy. There

More information

CALIBRATION HOW IT WORKS

CALIBRATION HOW IT WORKS HIGH POWER SOLUTIONS POWER DETECTORS ENERGY DETECTORS At Gentec-EO, we understand that the essence of our business since 40 years has been delivering accuracy. There are no half measures: it either measures

More information

PCT Workshop Before you leave the office

PCT Workshop Before you leave the office Before you leave the office Documentation Suitable Equipment Calibration Training Preparation Documentation Currently documentation for the scheme consists of: Association Of Noise Consultants PCT Registration

More information

SLIP RESISTANCE TESTING OF ENDURO-MESH PANEL

SLIP RESISTANCE TESTING OF ENDURO-MESH PANEL ATTAR TEST REPORT NO: 10/4302 26 August 2010 Total Pages: 2 SLIP RESISTANCE Job No: M10/4302 Subject: Introduction: SLIP RESISTANCE TESTING OF ENDURO-MESH PANEL You supplied us with two (2) samples of

More information

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services INFRASTRUCTURE TECHNOLOGIES Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services Test Report Author: Peter Gordon Report number: FSP 1960 Date: 5 February 2019 Client:

More information

AS Australian Standard. Guards and patrols. This is a free 6 page sample. Access the full version online.

AS Australian Standard. Guards and patrols. This is a free 6 page sample. Access the full version online. AS 4421 1996 Australian Standard Guards and patrols This Australian Standard was prepared by Committee EL/31, Intruder Alarm Equipment and Installations. It was approved on behalf of the Council of Standards

More information

Fire-resistance test on fire collars protecting a concrete slab penetrated by services

Fire-resistance test on fire collars protecting a concrete slab penetrated by services INFRASTRUCTURE TECHNOLOGIES Fire-resistance test on fire collars protecting a concrete slab penetrated by services Test Report Author: Chris Wojcik Report number: FSP 1735 Date: 8 September 2016 Client:

More information

Test Report. Appliance EMF Testing

Test Report. Appliance EMF Testing Project: 11014506A Date: November 6, 2015 Model: 120V_WWF13NW Test Report On Appliance EMF Testing Copyright 2005 UL LLC UL LLC authorizes the above-named company to reproduce this Report provided it is

More information

BCTC CARPET TECHNICAL CENTRE

BCTC CARPET TECHNICAL CENTRE Wira House West Park Ring Road Leeds, LS16 6QL Tel: +44 (0)113 259 1999 Fax: +44 (0)113 278 0306 Web: http://www.bttg.co.uk/bctc Email: CSLeeds@bttg.co.uk 7 September 2010 Page 1 of 7 Client: Rectory Farm

More information

Contact person Date Reference Page Richard Johansson P (2) Fire Research

Contact person Date Reference Page Richard Johansson P (2) Fire Research issued by an Accredited Testing Laboratory Contact person Richard Johansson 215-8-13 5P4413 1 (2) Fire Research +46 1 516 56 75 richard.johansson@sp.se 12 ISO/IEC 1725 Sklejka-Pisz Paged S.A Ul. kwiatowa

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AUSTRALIAN NATIONAL TESTING LABORATORIES PTY. LTD. Unit 17, 15 Suscatand Street Rocklea 4106, Queensland, Australia Jeff Profke Phone: 61 7 32740737 THERMAL

More information

Report VNLF Test Report

Report VNLF Test Report Report VNLF 081158.1 Test Report Applicant KLEEN-TEX Industries in Europa GmbH Münchner Straße 21 6330-Kufstein Austria Reference Mrs. Antje Schlegel Application Determination ofthe burning behaviour according

More information

SAIME. KaleidoSeries. 300x300,300x600,600x600&450x900mm Mat(R10CP4),Roc(R12P5)&Lappato. Bianco Beige Avorio. Cappucino Cenere Fango.

SAIME. KaleidoSeries. 300x300,300x600,600x600&450x900mm Mat(R10CP4),Roc(R12P5)&Lappato. Bianco Beige Avorio. Cappucino Cenere Fango. SAIME KaleidoSeries 300x300,300x600,600x600&450x900mm Mat(R10CP4),Roc(R12P5)&Lappato Bianco Beige Avorio Cappucino Cenere Fango Grigio Mandorla Marone Mokka Nero Registered Testing Authority - CSIRO 29

More information

Analysis Report

Analysis Report Prestige Carpets bvba Dhr. Dirk Santens Klein Frankrijk 38 9600 RONSE Your notice of Your reference Date 19-06-2013 24-07-2013 Required tests : Identification number T1309624 Information given by the client

More information

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services INFRASTRUCTURE TECHNOLOGIES Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services Test Report Author: Mario Lara-Ledermann Report number: FSP 1658 Date: 15 January

More information

Type: Play house Length: 1195 mm Width: 1195 mm Height: 1740 mm Materials: 18,7 mm laminated wood

Type: Play house Length: 1195 mm Width: 1195 mm Height: 1740 mm Materials: 18,7 mm laminated wood Interia Prosjekt AS Attn.: Lars Johansen Olav Tryggvasons Gate 29 N-7011 Trondheim Order no. 654289-6 Appendices 4 Initials laha/prni/hbs Test Report Material: Model: Lavvo Type: Play house Length: 1195

More information

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for: Classification of reaction to fire performance in accordance with EN 13501-1: 2007 +A1: 2009 on Superfoil SFNC Prepared for: Boulder Developments Ltd Black Horse Farm Main Street Norwell Nottinghamshire

More information

AS/NZS ISO/IEC :2012

AS/NZS ISO/IEC :2012 AS/NZS ISO/IEC 14763.3:2012 (ISO/IEC 14763-3:2011, MOD) Australian/New Zealand Standard Telecommunications installations Implementation and operation of customer premises cabling Part 3: Testing of optical

More information

QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY

QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY Seville, 31.03.2016 Pedro Martin, RadLab Radiation Facility Supervisor TÜV NORD GROUP QUALITY ASSURANCE AND SAFETY «Anything that can go

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 1841.1:2007 AS/NZS 1841.1:2007 Australian/New Zealand Standard Portable fire extinguishers Part 1: General requirements AS/NZS 1841.1:2007 This Joint Australian/New Zealand Standard was prepared

More information

WITH OMRON E5CC CONTROL

WITH OMRON E5CC CONTROL LABORATORY OVENS, FAN FORCED & GRAVITY CONVECTION. MODELS: TO-152G & TOH-152G TO-152F, TOH-152F & TO-235F TO-330F & TO-500F WITH OMRON E5CC CONTROL Thermoline Scientific Equipment Pty. Ltd. T/A Thermoline

More information

REFRIGERATED RECIRCULATORY COOLER

REFRIGERATED RECIRCULATORY COOLER REFRIGERATED RECIRCULATORY COOLER MODEL INCLUDES: TRC-3000 Thermoline Scientific Equipment Pty. Ltd. T/A Thermoline Scientific ABN 80 000 859 129 10-12 Ross Place. Wetherill Park N.S.W. 2164. Australia.

More information

Australian/New Zealand Standard TM

Australian/New Zealand Standard TM 1 AS/NZS 1841.8:2007 AS/NZS 1841.8:2007 Australian/New Zealand Standard TM Portable fire extinguishers Part 8: Specific requirements for non-rechargeable type extinguishers 1 SCOPE This Standard specifies

More information

CSIRO. Oceanographic Calibration Facility. Hobart, Tasmania, Australia. Robert Kay Calibration Engineer June 2017

CSIRO. Oceanographic Calibration Facility. Hobart, Tasmania, Australia. Robert Kay Calibration Engineer June 2017 CSIRO Oceanographic Calibration Facility Hobart, Tasmania, Australia Robert Kay Calibration Engineer June 2017 OCEANS & ATMOSPHERE / ENGINEERING & TECHNOLOGY CSIRO Oceans & Atmosphere The Commonwealth

More information

Patrick Port Botany Container Terminal Biannual Environmental Noise Compliance Monitoring June 2015

Patrick Port Botany Container Terminal Biannual Environmental Noise Compliance Monitoring June 2015 REPORT 1184R1 Biannual Environmental Noise Compliance Monitoring June 15 PREPARED FOR: PO Box 197 Botany NSW 1455 7 August 15 Biannual Environmental Noise Compliance Monitoring June 15 PREPARED BY: Pty

More information

Playscape Surfacing. Wicksteed - Naturally

Playscape Surfacing. Wicksteed - Naturally Playscape Surfacing Wicksteed - Naturally 231 Playscape Wet Pour Playscape Wet Pour Playscape Wet Pour is suitable for all installations where safety surfacing is a requirement, up to the appropriate Free

More information

CERTIFICATE. about Product Conformity {QAL 1) Number of Certificate: _02

CERTIFICATE. about Product Conformity {QAL 1) Number of Certificate: _02 Umwelt Bundes Amt For our Environment /;;;!. TÜVRheinland Precisely Right. CERTIFICATE about Product Conformity {QAL 1) Number of Certificate: 0000026912_02 Certified AMS: Manufacturer: Test Institute:

More information

ASTM E 662 Rate of Smoke Generation of OXIFREE TM198"

ASTM E 662 Rate of Smoke Generation of OXIFREE TM198 ELECTRONIC COPY ASTM E 662 Rate of Smoke Generation of OXIFREE TM198" A Report To: Oxifree Global LLC 22955 State Highway 249, Suite 6 Tomball, TX 77375 USA Phone: (281) 251-7171 E-mail: ed.hall@oxifree.com

More information

Fire resistance test on fire collars protecting a concrete slab penetrated by services

Fire resistance test on fire collars protecting a concrete slab penetrated by services INFRASTRUCTURE TECHNOLOGIES Fire resistance test on fire collars protecting a concrete slab penetrated by services Test Report Author: Mario Lara Report number: FSP 1601a Date: 11 April 2014 (This report

More information

Sound Performance Rating of Non-ducted Indoor Airconditioning

Sound Performance Rating of Non-ducted Indoor Airconditioning AHRI Standard 350 2015 Standard for Sound Performance Rating of Non-ducted Indoor Airconditioning and Heat Pump Equipment IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does not certify

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION IEC TS 62941 Edition 1.0 2016-01 Terrestrial photovoltaic (PV) modules Guidelines for increased confidence in PV module design qualification and type approval INTERNATIONAL ELECTROTECHNICAL

More information

Ultrasonic Clamp-On Flow Meter Testing

Ultrasonic Clamp-On Flow Meter Testing Ultrasonic Clamp-On Meter Testing Carried out for Micronics Ltd By Colin Judd Ultrasonic Clamp-On Meter Testing Carried out for: Micronics Ltd Unit B4 Business Centre Davies Way Loudwater High Wycombe

More information

CERTIFICATION SAFETY & BEYOND

CERTIFICATION SAFETY & BEYOND CERTIFICATION SAFETY & BEYOND Ferhun Emeksiz & R.M ( Max) Bradbury Client Manager & Fire Products Program Manager Global-Mark Pty Ltd Content Product Certification Understanding the framework Fundamental

More information

AS/NZS 4012:1999 AS/NZS

AS/NZS 4012:1999 AS/NZS Australian/New Zealand Standard AS/NZS 4012:2014 Incorporating Amendment No. 1 Domestic solid fuel burning appliances Method for determination of power output and efficiency Superseding AS/NZS 4012:1999

More information

FIRE-RESISTANCE TEST ON FIRE COLLARS PROTECTING A PLASTERBOARD WALL PENETRATED BY SERVICES

FIRE-RESISTANCE TEST ON FIRE COLLARS PROTECTING A PLASTERBOARD WALL PENETRATED BY SERVICES FIRE-RESISTANCE TEST ON FIRE COLLARS PROTECTING A PLASTERBOARD WALL PENETRATED BY SERVICES Report number FSP 1360 CSIRO job number SP3241 Date of issue 31 JULY 2009 Client SNAP FIRE SYSTEMS PTY LTD. Commercial-in-confidence

More information

Technical Assessment Guideline Applicable for the Kiwa KQ Certification Scheme:

Technical Assessment Guideline Applicable for the Kiwa KQ Certification Scheme: Technical Assessment Guideline Applicable for the Kiwa KQ Certification Scheme: Solar products and components Accreditation Kiwa Italia S.p.A. Via Treviso 32/34 31020 San Vendemiano (TV) Italia Tel: +39

More information

Optics & Radiometry Laboratory

Optics & Radiometry Laboratory Optics & Radiometry Laboratory Scope of accredited testing The Optics and Radiometry Laboratory is accredited by the National Association of Testing Authorities, Australia to ISO 17025 Accreditation number

More information

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3. Rev. 1 03/05/2015 ANNEX A to the Yokogawa Corporation of America Quality Assurance Manual For Additional Requirements selectively applied to ATEX and IECEx certified products CONTENTS 1. Scope 2. Purpose

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ARTESYN PRODUCT TESTING SERVICES 2900 South Diablo Way, Suite 190 Tempe, AZ 85282 Tom Tuttle Phone: 602 228 7869 Email: tom.tuttle@artesyn.com ELECTRICAL (EMC)

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 COMPLIANCE CERTIFICATION SERVICES, INC. 1 Xindian Laboratory No.163-1, Jhongsheng Road Xindian District, New Taipei City 23151, Taiwan, R.O.C. Contact: Kurt

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 2293.2:1995 Australian/New Zealand Standard Emergency evacuation lighting for buildings AS/NZS 2293.2:1995 This Joint Australian/New Zealand Standard was prepared by Joint Technical Committee LG/7,

More information

argos: model specifications Technical Data 2 Installation 3 Operate the Argos 5 Safety Rules 8 Certification 9

argos: model specifications Technical Data 2 Installation 3 Operate the Argos 5 Safety Rules 8 Certification 9 argos: model specifications Technical Data 2 Installation 3 Operate the Argos 5 Safety Rules 8 Certification 9 Technical Data Please read this notice carefully. Australian Standards Test Results Manufacturer

More information

Technical Note. Noise emission from Dehumidifier Type C65E TC Project no.: I Page 1 of July 2016

Technical Note. Noise emission from Dehumidifier Type C65E TC Project no.: I Page 1 of July 2016 Technical Note Noise emission from Dehumidifier Type C65E-11.1 Performed for COTES A/S Project no.: I101033 Page 1 of 10 01 July 2016 DELTA Venlighedsvej 4 2970 Hørsholm Denmark Tel. +45 72 19 40 00 Fax

More information

SOLAR HOT WATER AND HEAT PUMP BOOSTER ENERGY CALCULATION METHODOLOGY

SOLAR HOT WATER AND HEAT PUMP BOOSTER ENERGY CALCULATION METHODOLOGY SOLAR HOT WATER AND HEAT PUMP BOOSTER ENERGY CALCULATION METHODOLOGY PART A: CALCULATION METHODOLOGY FOR SOLAR WATER HEATERS AND HEAT PUMP WATER HEATERS WITH A VOLUMETRIC CAPACITY OF UP TO AND INCLUDING

More information

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: _02

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: _02 Umwelt Bundes Amt For our Environment /;;!.. TÜVRheinland Precisely Right. CERTIFICATE on Product Conformity (QAL 1) Number of Certificate: 0000001014_02 Certified AMS: Manufacturer: Test Institute: 4500

More information

NEUTRAL SALT SPRAY TESTING REPORT TEST RESULTS. Kim Bray Materials Testing Officer AUTHORISED SIGNATORY. Bureau Veritas

NEUTRAL SALT SPRAY TESTING REPORT TEST RESULTS. Kim Bray Materials Testing Officer AUTHORISED SIGNATORY. Bureau Veritas 35-37 STIRLING STREET THEBARTON, SA 5031 P.O BOX 338, TORRENSVILLE PLAZA,SA. 5031 A.B.N. 86 000 928 816 Tel: (08) 8416 5260 Fax: (08) 8260 2760 NEUTRAL SALT SPRAY TESTING REPORT Client: Action Corrosion

More information

Woven Polyester High. ACETex the proven choice for: n Embankment Support over piles. n Support over voids

Woven Polyester High. ACETex the proven choice for: n Embankment Support over piles. n Support over voids Australian Company // Global Expertise Woven Polyester High Strength Geotextile ACETex the proven choice for: SOIL REINFORCEMENT IN APPLICATIONS OF: n Embankment Support over Soft Soils n Embankment Support

More information

How to use guide for safety surfacing products supplied by Playbark.com

How to use guide for safety surfacing products supplied by Playbark.com How to use guide for safety surfacing products supplied by Playbark.com Several considerations need to be assessed before selecting a specific play grade safety surfacing, less commonly known as a Loose

More information

GUIDELINE FOR THE APPLICATION OF SRPS CEN/TS WHEN GRANTING ACCREDITATION TO TESTING LABORATORIES

GUIDELINE FOR THE APPLICATION OF SRPS CEN/TS WHEN GRANTING ACCREDITATION TO TESTING LABORATORIES GUIDELINE FOR THE APPLICATION OF SRPS CEN/TS 15675 WHEN GRANTING ACCREDITATION TO TESTING LABORATORIES Any differences between the Serbian and English versions of this document are not intended, but if

More information

PQS Independent type-testing protocol

PQS Independent type-testing protocol PQS Independent type-testing protocol WHO/XXX Original: English Distribution: General TITLE: Wall-mounted pen recording thermometer Product verification protocol: E06/TR04VP Applies to specification ref(s):

More information

Australian Standard. Electroacoustics Sound calibrators AS IEC This is a free 7 page sample. Access the full version online.

Australian Standard. Electroacoustics Sound calibrators AS IEC This is a free 7 page sample. Access the full version online. AS IEC 60942 2004 IEC 60942:2003 AS IEC 60942 Australian Standard Electroacoustics Sound calibrators This Australian Standard was prepared by Committee AV-002, Acoustics Instrumentation and Measurement

More information

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50. Classification of reaction to fire performance in accordance with BS EN 13501-1: 2007 +A1: 2009 on Sandwich Panel, WP 50 Prepared for: Sandwich Panel Factory Jeddah Saudi Arabia 13 July 2011 0578 Page

More information

Fire Protection Industry Board (ODS & SGG) Risk Management Plan. A risk management plan for storing and disposing of fire extinguishing agents

Fire Protection Industry Board (ODS & SGG) Risk Management Plan. A risk management plan for storing and disposing of fire extinguishing agents Fire Protection Industry Board (ODS & SGG) Risk Management Plan A risk management plan for storing and disposing of fire extinguishing agents Version 6: March 2018 Contents Introduction.... 5 Policy Statement...

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 LABORATOIRE D ESSAIS CEM INC. 1490-D Nobel Street Boucherville, Quebec, Canada J4B 5H3 Mr. Xavier Couste Phone: 450 868 0360 Email: Xavier.Couste@nts.com ELECTRICAL

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION IEC/TS 62600-100 Edition 1.0 2012-08 colour inside Marine energy Wave, tidal and other water current converters Part 100: Electricity producing wave energy converters Power performance

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 4692.1:2005 AS/NZS 4692.1:2005 Australian/New Zealand Standard Electric water heaters Part 1: Energy consumption, performance and general requirements AS/NZS 4692.1:2005 This Joint Australian/New

More information

AS AS Australian Standard. Potting mixes. This is a free 7 page sample. Access the full version online.

AS AS Australian Standard. Potting mixes. This is a free 7 page sample. Access the full version online. AS 3743 2003 AS 3743 Australian Standard Potting mixes This Australian Standard was prepared by Committee CS-037, Garden Soils and Potting Mixes. It was approved on behalf of the Council of Standards Australia

More information

Australian Standard. Emergency escape lighting and exit signs for buildings. Part 1: System design, installation and operation AS 2293.

Australian Standard. Emergency escape lighting and exit signs for buildings. Part 1: System design, installation and operation AS 2293. AS 2293.1 2005 AS 2293.1 2005 Australian Standard Emergency escape lighting and exit signs for buildings Part 1: System design, installation and operation This Australian Standard was prepared by Committee

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 2293.2:1995 (Incorporating Amendment Nos 1 and 2) AS/NZS 2293.2:1995 Australian/New Zealand Standard Emergency escape lighting and exit signs for buildings AS/NZS 2293.2:1995 This Joint Australian/New

More information

AS/NZS 2: 1067:2003 AS/NZS

AS/NZS 2: 1067:2003 AS/NZS Australian/New Zealand Standard AS/NZS 1067.2:2016 (ISO 12311:2013, IDT) Eye and face protection Sunglasses and fashion spectacles Part 2: Test methods Superseding in part AS/NZS 1067:2003 AS/NZS 1067.2:2016

More information

ASSESSMENT REVIEW. Review of Assessment Report WFRA C91415

ASSESSMENT REVIEW. Review of Assessment Report WFRA C91415 ASSESSMENT REVIEW Review of Assessment Report WFRA C91415 Fire resistance performance of steel electrical wall boxes mounted in plasterboard partitions with modified mounting arrangements, box design and

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 2201.1:2007 AS/NZS 2201.1:2007 Australian/New Zealand Standard Intruder alarm systems Part 1: Client s premises Design, installation, commissioning and maintenance AS/NZS 2201.1:2007 This Joint

More information

AS/NZS :1995. Emergency escape lighting and exit signs for buildings AS/NZS :1995. Part 2: Inspection and maintenance

AS/NZS :1995. Emergency escape lighting and exit signs for buildings AS/NZS :1995. Part 2: Inspection and maintenance Australia/New Zealand Standard AS/NZS 2293.2:1995 Incorporating Amendment No. 1, 2, and 3 Emergency escape lighting and exit signs for buildings Superseding in part NZS 6742:1971 and AS 2293.2 1987 AS/NZS

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 COMPLIANCE ENGINEERING PTY LTD 90 Indian Drive Keysborough, Victoria 3173, AUSTRALIA Mr. Simon Grilj Phone: 61 3 9763 3079 Email: simon@compeng.com.au ELECTRICAL

More information

Sound Performance Rating of Outdoor Unitary Equipment

Sound Performance Rating of Outdoor Unitary Equipment 2015 Standard for Sound Performance Rating of Outdoor Unitary Equipment AHRI Standard 270 WITH ADDENDUM 1, Sound Performance Rating of Outdoor Unitary Equipment March 2016 Note: This addendum is not ANSI

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 INTERTEK TESTING SERVICES SHANGHAI Bl. No. 86, 1198 Qinzhou Road (North) Shanghai 200233, PEOPLE S REPUBLIC OF CHINA Leah Xu leah.xu@intertek.com Phone: +86

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 NATIONAL TECHNICAL SYSTEMS (NTS) - LONGMONT 1736 Vista View Drive Longmont, CO 80504-5242 Mr. Eric Loucks Phone: 303 776 7249 ELECTRICAL Valid To: August 31,

More information

Patrick Port Botany Container Terminal Biannual Environmental Noise Compliance Monitoring May 2017

Patrick Port Botany Container Terminal Biannual Environmental Noise Compliance Monitoring May 2017 REPORT 160095R1 Biannual Environmental Noise Compliance Monitoring May 2017 PREPARED FOR: PO Box 197 Botany NSW 1455 6 June 2017 Biannual Environmental Noise Compliance Monitoring May 2017 PREPARED BY:

More information

Gas Technology Services

Gas Technology Services Gas Technology Services Gas Technology Services Gas Technology Services is a subsidiary of Australian technical consultancy Vipac Engineers & Scientists Ltd. Vipac is a leading testing laboratory, engineering

More information

Draft for Comment Please comments to Part A(i)

Draft for Comment Please  comments to Part A(i) Draft for Comment Please email comments to info@plcouncil.com.au Part A(i) PRODUCT SPECIFICATION OF PHOTOLUMINESCENT EXIT SIGNS (v2.1) SECTION 1 - PRINCIPLES 1.1 Scope This standard sets out the product

More information

AS/NZS 3190:2011 AS/NZS

AS/NZS 3190:2011 AS/NZS AS/NZS 3190:2016 Australian/New Zealand Standard Approval and test specification Residual current devices (currentoperated earth-leakage devices) Superseding AS/NZS 3190:2011 AS/NZS 3190:2016 AS/NZS 3190:2016

More information

SIZES AVAILABLE INDUSTRIAL: ARCHITECTUAL STEP NOSINGS

SIZES AVAILABLE INDUSTRIAL: ARCHITECTUAL STEP NOSINGS SIZES AVAILABLE INDUSTRIAL: pg1 PRODUCT CODE DIMENSIONS ALN1 ALN2 ALN3 ALNCP VISISTRIP SIZES AVAILABLE pg2 Architectural Step Covers are available at any lengths up to 6 metres. Special run profile can

More information

Level 1. Certificate of Conformity. Australian Certification Services Pty Ltd grants to the WaterMark User: Wallgate Ltd. Trading as Wallgate Ltd

Level 1. Certificate of Conformity. Australian Certification Services Pty Ltd grants to the WaterMark User: Wallgate Ltd. Trading as Wallgate Ltd Level 1 Certificate of Conformity Australian Certification Services Pty Ltd grants to the WaterMark User: Trading as the right to use the WaterMark as shown above in conjunction with the Certificate No.

More information

PERFORMANCE EVALUATION TEST REPORT. Rendered to: GREENFIELD MANUFACTURING COMPANY. PRODUCT: Hanger Screws

PERFORMANCE EVALUATION TEST REPORT. Rendered to: GREENFIELD MANUFACTURING COMPANY. PRODUCT: Hanger Screws PERFORMANCE EVALUATION TEST REPORT Rendered to: GREENFIELD MANUFACTURING COMPANY PRODUCT: Hanger Screws Report No: Report Date: 01/12/11 Expiration Date: 12/28/14 Product: Hanger Screws PERFORMANCE EVALUATION

More information

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links TB Number 004 This bulletin is supplied for information only and is intended to provide

More information

Test Report: ICL/CR15/11/087

Test Report: ICL/CR15/11/087 Interscience Fire Laboratory Building 63 Haslar Marine Technology Park Haslar Road, Gosport Hampshire PO12 2AG United Kingdom Tel. : +44 (0) 20 8692 5050 Fax.: +44 (0) 20 8692 5155 Email: firetesting@intersciencecomms.co.uk

More information

Australian Standard. Fire detection, warning, control and intercom systems System design, installation and commissioning. Part 1: Fire AS 1670.

Australian Standard. Fire detection, warning, control and intercom systems System design, installation and commissioning. Part 1: Fire AS 1670. AS 1670.1 2004 (Incorporating Amendment No. 1) AS 1670.1 2004 Australian Standard Fire detection, warning, control and intercom systems System design, installation and commissioning Part 1: Fire This Australian

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 1338.1:2012 AS/NZS 1338.1:2012 Australian/New Zealand Standard Filters for eye protectors Part 1: Filters for protection against radiation generated in welding and allied operations AS/NZS 1338.1:2012

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. F2 LABS Peters Road Middlefield, OH Wendy Fuster Phone: Ext.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. F2 LABS Peters Road Middlefield, OH Wendy Fuster Phone: Ext. SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 F2 LABS 16740 Peters Road Middlefield, OH 44062 Wendy Fuster Phone: 301 253 4500 Ext. 101 ELECTRICAL (EMC) Valid To: November 30, 2019 Certificate Number: 0793.02

More information

Drawer fronts: 16 mm particleboard Doors: 16 mm particleboard This report covers the models Nonstop, Sprinter, Genese

Drawer fronts: 16 mm particleboard Doors: 16 mm particleboard This report covers the models Nonstop, Sprinter, Genese Holmris A/S Attn.: Lene Nissen Odinsvej 5 8850 Bjerringbro Order no. 419556 Appendices 2 Initials laha/flg/hbs Test Report Material: Model: Office shelf Type: Office shelf Lab.no.: 419556B Length 809 mm

More information

LABORATORY ILLUMINATED FLOTATION BATH

LABORATORY ILLUMINATED FLOTATION BATH LABORATORY ILLUMINATED FLOTATION BATH MODELS INCLUDE: TFB-1 Thermoline Scientific Equipment Pty. Ltd. ABN 80 000 859 129 10-12 Ross Place Wetherill Park NSW 2164. P.O. Box 6862 Wetherill Park DC NSW 1851

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 1337.1:2010 (Incorporating Amendment No. 1) AS/NZS 1337.1:2010 Australian/New Zealand Standard Personal eye protection Part 1: Eye and face protectors for occupational applications AS/NZS 1337.1:2010

More information

Australian Standard. Functional safety of electrical/electronic/programmable electronic safety-related systems. Part 0: Functional safety and AS 61508

Australian Standard. Functional safety of electrical/electronic/programmable electronic safety-related systems. Part 0: Functional safety and AS 61508 AS 61508.0 2006 IEC/TR 61508-0:2005 AS 61508.0 2006 Australian Standard Functional safety of Part 0: Functional safety and AS 61508 This Australian Standard was prepared by Committee IT-006, Industrial

More information

Note 1: TC 61 does not deal with appliances which are already explicitly covered by the scope of other IEC Technical Committees.

Note 1: TC 61 does not deal with appliances which are already explicitly covered by the scope of other IEC Technical Committees. SMB/6486/R STRATEGIC BUSINESS PLAN (SBP) IEC/TC OR SC: SECRETARIAT: DATE: IEC/TC 61 United States May 2018 A. STATE TITLE AND SCOPE OF TC TITLE: IEC TC 61, Safety of household and similar electrical appliances.

More information

New Developments in the IEC61511 Edition 2

New Developments in the IEC61511 Edition 2 New Developments in the IEC61511 Edition 2 Presented by Dr Issam Mukhtar PhD(Eng.) TÜV FS Expert (IDNo.:117/06) 6 th May 2013 2010 Invensys. All Rights Reserved. The names, logos, and taglines identifying

More information

Supertron Sensing Pte Ltd Certificate No. : LA C Blk 16 Kallang Place #07-04 Issue No. : 4 Singapore Date : 04 February 2015

Supertron Sensing Pte Ltd Certificate No. : LA C Blk 16 Kallang Place #07-04 Issue No. : 4 Singapore Date : 04 February 2015 Supertron Sensing Pte Ltd Certificate No. : LA-2011-0485-C Blk 16 Kallang Place #07-04 Issue No. : 4 Singapore 339156 Date : 04 February 2015 Page : 1 of 5 FIELD OF TESTING : Calibration and Measurement

More information

EXPRESSION OF INTEREST (EOI) FOR. Fire Fighting System (FFS)

EXPRESSION OF INTEREST (EOI) FOR. Fire Fighting System (FFS) EXPRESSION OF INTEREST (EOI) FOR Fire Fighting System (FFS) KWtE-03-PR-EO-ACC-0 Rev01 11 Version: Date: Prepared by: Approved: 01 7/11/18 VMC AMN Page 1 OF 5 1 Project overview ACCIONA s Engineering, Procuring

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61755-2-4 Edition 1.0 2015-01 colour inside Fibre optic interconnecting devices and passive components Connector optical interfaces Part 2-4: Connection parameters of non-dispersion

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61514-2 First edition 2004-01 Industrial process control systems Part 2: Methods of evaluating the performance of intelligent valve positioners with pneumatic outputs IEC 2004

More information

You can contact us on: T E.

You can contact us on: T E. NATIONWIDE CONTRACTORS DCM Surfaces are available for nationwide contracts. Based in the North West we dispatch teams throughout the UK and provide quotations, site visits and honest advice. THE BEST MATERIALS

More information

ISO 7183 INTERNATIONAL STANDARD. Compressed-air dryers Specifications and testing. Sécheurs à air comprimé Spécifications et essais

ISO 7183 INTERNATIONAL STANDARD. Compressed-air dryers Specifications and testing. Sécheurs à air comprimé Spécifications et essais INTERNATIONAL STANDARD ISO 7183 Second edition 2007-12-15 Compressed-air dryers Specifications and testing Sécheurs à air comprimé Spécifications et essais Reference number ISO 7183:2007(E) ISO 2007 PDF

More information

DR AS 5389:2016 Space heating and cooling and ventilation systems Calculation of energy consumption. The physical testing

DR AS 5389:2016 Space heating and cooling and ventilation systems Calculation of energy consumption. The physical testing Vipac Engineers & Scientists DR AS 5389:2016 Space heating and cooling and ventilation systems Calculation of energy consumption The physical testing Sydney 16 August 2016 Introduction to Vipac AGENDA

More information

AS/NZS 3133:2008 AS/NZS

AS/NZS 3133:2008 AS/NZS Incorporating Amendment No. 1 and 2 Australian/New Zealand Standard Approval and test specification Air-break switches Superseding AS/NZS 3133:2008 This joint Australian/New Zealand standard was prepared

More information

MEASUREMENT AND TEST REPORT

MEASUREMENT AND TEST REPORT MEASUREMENT AND TEST REPORT For United GULF GATE Co. Aladel Tower,F21,Fahad Al Salem St., State of KUWAIT Model: XT-60 IP-PBX This Report Concerns: Original Report Equipment Type: IP PBX Test Engineer:

More information