PCT Workshop Before you leave the office
|
|
- Lillian Walton
- 5 years ago
- Views:
Transcription
1 Before you leave the office
2 Documentation Suitable Equipment Calibration Training Preparation
3 Documentation Currently documentation for the scheme consists of: Association Of Noise Consultants PCT Registration Scheme Handbook February 2016 Good Practice Guide - ANC Registration Scheme For Precompletion Testing Version New version of the Good Practice Guide available today Iain Critchley to discuss later!
4 Documentation Relevant Standards Which standard should measurements be made to? BS EN ISO 140 Series OR BS EN ISO 16283
5 Documentation BS EN ISO 140 Series NOT BS EN ISO Relevant Standards ADE refers to dated versions of the standard and so ISO 140 (4 & 7) remain However, BS EN ISO 16283:2014 Part 1 (and Part 2 for impact) should be used as guidance, replacing BS EN ISO :2004 for special situations in the field, which is also now withdrawn.
6 Documentation Relevant Standards BS EN ISO 16283:2014 Parts 1&2 usefully permit the tester to remain in the test room and describe several manual scanning techniques, which the withdrawn ISO 140 Parts 4 and 7 do not. BS EN ISO 16283:2014 Parts 1&2 also describe impulsive sound sources for reverberation time measurement, using reverse integration methods, according to BS EN ISO :2008, which the withdrawn ISO 140 Parts 4 and 7 do not.
7 Suitable Equipment Sound Level Meter Type 0 or 1 Class for octave and fractional octave filters On-site calibrators should comply with accuracy Class 1 Sound Source White/Pink Noise Suitable signal chain Loudspeaker/amplifier Omni-directional or Cabinet (BS EN ISO 140-4) Tapping Machine
8 Is my calibration valid? How frequent? Where? What needs to be checked? What standards?
9 What Needs to be Calibrated and When? Sound Level Meters (inc. microphone & pre-amp)? Calibrators? Tapping Machines? Sound Source? Loudspeaker? Loudspeaker Stand?
10 What Needs to be Calibrated? Sound Level Meters two years (or if pre-amp/microphone changed) Calibrators two years with annual check or every year Tapping Machines conformance check two years Sound Source none but Loudspeaker none but Loudspeaker Stand tape measure
11 Calibrators Calibrators to at least traceable standards, by a competent laboratory at intervals not exceeding one year. Alternatively, calibrator in-house against a known calibrator of the same type which has been calibrated by the competent laboratory within the previous twelve month period. In that case the calibration interval between traceable laboratory calibrations, for the calibrator, can be every two years. The in-house calibration checks must be formally recorded and the records supplied with the other instrument calibration certificates when requested as part of a company audit.
12 What is a Competent Laboratory?
13 What is a Competent Laboratory? The scheme does not require members to only use UKAS accredited laboratories A valid certificate of calibration should be obtained from a calibration laboratory that demonstrates competence, measurement capability and traceability to National standards. It is the Members responsibility to satisfy themselves of this as the ANC does not provide an Approved List of non-ukas laboratories.
14
15 Common Calibration Audit Issues Make sure your list of equipment includes the calibration certificate number and date Double check to make sure they are correct Check again No, really, check it again
16 Is my sound source stable? The measurement procedure depends on the source room signal being constant. Check periodically under controlled conditions that the source level measured over two 30 second periods does not vary by more than 1 db in any ⅓-octave band in the measured frequency range when neither microphone or loudspeaker are moved. If the equipment is found not to comply, the test results which have been taken since the previous check will be thrown into doubt; therefore a suitable period should be chosen to minimise this risk
17 Is my sound source stable? wireless radio links The same procedure should be used for both source and receiver room measurements. The tester should be satisfied that the system has the capability to handle the maximum signal that is transmitted, over the required frequency range and that it is stable. Their use should be included in all assessments of source stability and estimates of uncertainty.
18 Using two sound sources If more than one sound source is used simultaneously, the output power of each source must be similar in each relevant frequency band. The standard requires that sound sources must be similar for the two loudspeaker method. Taken to mean similar type; e.g. cabinet or omni loudspeaker with similar noise source. Most important aspect is that output power must be similar in each frequency band
19 Training Can you use the equipment Can you use the spreadsheet or software to carry out the calculations Are you sure you know all of the setup requirements for the meter to feed into the software Are you up to date with methodology and standards
20 Can I use it? It is OK to use hired equipment but please make sure you have had a trial run or are familiar with the equipment In-house witness checks should be carried out regularly to pass on best practice For example, if specific meter settings are required for proprietary software to work, be sure there is a method for checking the settings
21 Preparation Have you been able to plan the rooms to be tested using drawings and calculate volumes? Are you confident about the construction types and how many groups there are? Will the site be quiet? Is there power/adequate lighting? Do they know you re coming? Do you know where it is? Is there parking? Have they paid
22 Preparation Is the equipment working? Try before you leave Do you have spares for possible problems, batteries, etc Adequate stock of survey sheets, etc Calibrate the meter and tapping machine before leaving the office Repeat on site Do you have a checklist
23 Do they know I m coming?
24
TABLE OF CONTENTS. 1.0 INTRODUCTION Scope References Test Specimen Description Summary 1
Page No. TOC-i TABLE OF CONTENTS Page No. 1.0 INTRODUCTION 1 1.1 Scope 1 1.2 References 1 1.3 Test Specimen Description 1 1.4 Summary 1 2.0 TEST PROCEDURES AND RESULTS 2 2.1 High Temperature Test 2 2.2
More informationAPI MANUAL OF PETROLEUM MEASUREMENT STANDARDS
API MANUAL OF PETROLEUM MEASUREMENT STANDARDS Chapter 22 Testing Protocols Section 1 General Guidelines for Developing Testing Protocols for Devices Used in the Measurement of Hydrocarbon Fluids Type Testing
More information1 Introduction - The rating level. 3 Subjective or objective analysis? 2 Determination of the adjustment for annoying tones
Noise can be said to be tonal if it contains a distinguishable, discrete, continuous note. This may include a whine, hiss, screech, hum, etc., and any such subjective finding is open to discussion when
More informationFor the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems
BAFE Scheme: SP203-1 Version 7.1: January 2019 FIRE SAFETY REGISTER Fire Protection Industry Scheme, Reference SP203-1 For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire
More informationQUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY
QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY Seville, 31.03.2016 Pedro Martin, RadLab Radiation Facility Supervisor TÜV NORD GROUP QUALITY ASSURANCE AND SAFETY «Anything that can go
More informationSupertron Sensing Pte Ltd Certificate No. : LA C Blk 16 Kallang Place #07-04 Issue No. : 4 Singapore Date : 04 February 2015
Supertron Sensing Pte Ltd Certificate No. : LA-2011-0485-C Blk 16 Kallang Place #07-04 Issue No. : 4 Singapore 339156 Date : 04 February 2015 Page : 1 of 5 FIELD OF TESTING : Calibration and Measurement
More informationTechnical Note. Noise emission from Dehumidifier Type C65E TC Project no.: I Page 1 of July 2016
Technical Note Noise emission from Dehumidifier Type C65E-11.1 Performed for COTES A/S Project no.: I101033 Page 1 of 10 01 July 2016 DELTA Venlighedsvej 4 2970 Hørsholm Denmark Tel. +45 72 19 40 00 Fax
More informationISO INTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 22868 Second edition 2011-03-01 Forestry and gardening machinery Noise test code for portable hand-held machines with internal combustion engine Engineering method (Grade 2 accuracy)
More informationTest Report for the determination of Critical Fall Height for Under Playground Surfacing with Plants
Page: 1 of 6 ABN 36 062 949 973 20/109A Bonds Rd Punchbowl NSW 2196 Test Report for the determination of Critical Fall Height for Under Playground Surfacing with Plants Specification: Australian Standard
More informationCALIBRATION HOW IT WORKS
HIGH POWER SOLUTIONS POWER DETECTORS ENERGY DETECTORS At Gentec-EO, we understand that the essence of our business since over 45 years has been delivering accuracy. There are no half measures: it either
More informationMGN 453 (M) Maritime and Coastguard Agency Logo MARINE GUIDANCE NOTE
Maritime and Coastguard Agency Logo MARINE GUIDANCE NOTE MGN 453 (M) FIRE PROTECTION Fire Retardant Treatment for Floor Coverings, Suspended Textile Materials, Upholstery Materials and Bedding Components
More informationSound Performance Rating of Outdoor Unitary Equipment
2015 Standard for Sound Performance Rating of Outdoor Unitary Equipment AHRI Standard 270 WITH ADDENDUM 1, Sound Performance Rating of Outdoor Unitary Equipment March 2016 Note: This addendum is not ANSI
More informationCO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE
CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 PPE-R/00.017 Version 2 RECOMMENDATION FOR USE Number of pages: 5 Approval stage : Approved on : Origin : Horizontal Committee, C2D Ad hoc group
More informationCALIBRATION HOW IT WORKS
HIGH POWER SOLUTIONS POWER DETECTORS ENERGY DETECTORS At Gentec-EO, we understand that the essence of our business since 40 years has been delivering accuracy. There are no half measures: it either measures
More informationSound Performance Rating of Non-ducted Indoor Airconditioning
AHRI Standard 350 2015 Standard for Sound Performance Rating of Non-ducted Indoor Airconditioning and Heat Pump Equipment IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does not certify
More informationSummer Works Scheme 2010
WCMS 01/2009 TO: PRIMARY AND POST PRIMARY SCHOOL AUTHORITIES Summer Works Scheme 2010 Devolved Capital Grants for Water Conservation Measures in Primary and Post Primary School Buildings Guide for School
More informationPressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"
D. EVALUATION ASSESSMENT PROCEDURES Guideline D-01 Guideline related to: Annex III, module G Is design approval by a notified body required under module G? Module G does not explicitly require formal design
More informationSwaging Machine Type H50-46ECO
ENDEAVOUR Int. Ltd. Tel +44 (0) 1225 446770 Fax +44 (0) 1225 446775 USER MANUAL Swaging Machine Type H50-46ECO Website: www.hydralok.net CONTENTS WARRANTY CONDITIONS... 3 EC DECLARATION OF CONFORMITY...
More informationA GUIDE TO THE REGULATORY REFORM ORDER (FIRE SAFETY) 2005 (RRO)
4 PEEL HOUSE,TAUNTON STREET,SHIPLEY,BN18 3NA TEL: 01274 595015 FAX: 01274 580804 EMAIL:sales@rosse-systems.co.uk A GUIDE TO THE REGULATORY REFORM ORDER (FIRE SAFETY) 2005 (RRO) THE PURPOSE OF THIS DOCUMENT
More informationCastle ULTIMUS Vibration Meter
Castle ULTIMUS Vibration Meter (GA2007) Human Vibration Meter The Concept The measurement of Hand Arm Vibration has seen rapid developments since the first ground-breaking product from Castle (The famous
More informationTest Report Garvan Enterprises Limited
Test Report 8526255. Garvan Enterprises Limited Page 1 of 14 Introduction. This report has been prepared by A Reeve and relates to the activity detailed below: Job/Registration Details Job number: 8526255
More informationCode of Practice // For the installation, inspection and testing of electrical installations tel/fax:
Code of Practice // For the installation, inspection and testing of electrical installations tel/fax: 0870 241 7687 email: mpba@mpba.biz Introduction // This code of practice provides guidance for manufacturers,
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 18738-2 First edition 2012-10-15 Measurement of ride quality Part 2: Escalators and moving walks Mesure de la qualité de déplacement Partie 2: Escaliers mécaniques et trottoirs
More informationPQS performance specification
PQS performance specification WHO/PQS/E06/TR04.1 Original: English Distribution: General TITLE: Wall-mounted pen recording thermometer Specification reference: E06/TR04.1 Product verification protocol:
More informationTechnical Note. Noise emission from Dehumidifier Type C22/CR100. TC Project no.: T Page 1 of January 2016
Technical Note Noise emission from Dehumidifier Type C22/CR100 Performed for COTES A/S TC-100899 Project no.: T211658 Page 1 of 9 15 January 2016 DELTA Venlighedsvej 4 2970 Hørsholm Denmark Tel. +45 72
More informationThermostatic mixing valve VADO-PRO-100P
Thermostatic mixing valve VADO-PRO-100P IMPORTANT Installer: This Manual is the property of the customer and must be retained with the product for maintenance and operational purposes INTRODUCTION Thermostatic
More informationSensor Systems Network Design and QA/QC Brian Stacey
Sensor Systems Network Design and QA/QC Brian Stacey Status of Air Quality Sensors and their use in (official) monitoring strategies, 13 Feb 2017 2 Discussion points Compliance monitoring overview Sensor
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT CONFORMITY CERTIFICATE This is to certify that the GC 866 PID airtoxic (Model A73022) manufactured by: Chromatotec / airmotec 15, Rue d Artiguelongue Saint -Antoine 33240 Val de Virvée France has
More informationFor the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems
BAFE Scheme: SP203-1 Version 5: May 2011 Fire Protection Industry Scheme, Reference SP203 Part 1 For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems British
More informationTinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect
connect The TE-4500 is a temperature and relative humidity data logger that plugs directly into a network point and communicates across a LAN. The logger can be managed as a standalone logger, in conjunction
More informationThe development history of sound level meter in Japan
The development history of sound level meter in Japan Masaharu Ohya Motivations to develop measuring instruments Demand from customer and social situation Change of law and regulation When new measurement
More informationULT Freezer Performance Testing Emerson Design Services Network Project #
ULT Freezer Performance Testing Emerson Design Services Network Project # 111686 Design Services Network Test Performed by: Dan Rice & Don Wenrich Design Services Network Report Prepared by: Robert V.
More informationReport Number BTC 15450A
Report Number BTC 15450A AN ACOUSTIC TEST REPORT COVERING LABORATORY SOUND INSULATION TESTS TO BS EN ISO 140-3:1995 ON A BRITISH GYPSUM GYPWALL AUDIO PARTITION WITH VARYING NUMBERS OF ELECTRICAL SOCKET
More informationTemperature and Calibration Capabilities
Temperature and Calibration Capabilities Sensors and Specialist Components Roxspur Measurement and Control 2 Temperature, Pressure, Flow, Level, Systems, Calibration & Service Who we are. TT Electronics
More informationTemperature and Calibration Capabilities
Temperature and Calibration Capabilities Industrial Sensing and Control Roxspur Measurement and Control 2 Who we are. TT Electronics is a global provider of engineered electronics for performance critical
More informationABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE
ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE isocket Smart Relay is a complex Smart House system which is installed in the fuse cabinet (electric cabinet) in the house. We therefore assume that
More informationConsumer vacuum breast-pumps
Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.de M.Eng. Philipp Meistring Telephone +49(89)85602 228 Philipp.Meistring@mbbm.com
More informationGUIDELINE FOR THE APPLICATION OF SRPS CEN/TS WHEN GRANTING ACCREDITATION TO TESTING LABORATORIES
GUIDELINE FOR THE APPLICATION OF SRPS CEN/TS 15675 WHEN GRANTING ACCREDITATION TO TESTING LABORATORIES Any differences between the Serbian and English versions of this document are not intended, but if
More informationConformity assessment procedures for the Alarm Components Scheme
Conformity assessment procedures for the Alarm RD_070, Issue 20 This guide describes the conformity assessment procedures for Alarm Components. This Alarm certifies that Alarm Components comply with technical
More informationType 5 Certifications:
: What are they and how do you use them for compliance? Intertek Cleeve Road, Leatherhead, Surrey KT22 7SB UK info.uk@intertek.com 01372 370900 www.intertek.com Contents Contents... 1 Introduction... 1
More informationGuide to Membership Assessments
Issue 10 July 2008 Guide to Membership Assessments 1. Introduction This guide is intended to assist companies in preparing for an assessment visit by SELECT. It supplements the SELECT Assessment Criteria
More informationLPS 1014 Scheme Requirements for certificated fire detection and alarm system firms. Presented by - Reg Grigg LPCB
LPS 1014 Scheme Requirements for certificated fire detection and alarm system firms Presented by - Reg Grigg LPCB The aim of this brief presentation Why are LPCB schemes specified? pedigree, experience,
More informationLoudspeaker Test. Report
ACOUSTIC & ELECTRO-ACOUSTIC CONSULTANTS Rayleigh House Partners: 21 Queen Anne s Place, Bush Hill Park P.W. Barnett MIOA, MASA, F.Inst., SCE, MAES North London EN1 2QB J.L. Goddard (administration) Tel:
More informationAlertMaxx2. Installation & Operating Manual. Ground Water (DMS-298) Pump Station High Level Alarm
Ground Water (DMS-298) Installation & Operating Manual Pump Station High Level Alarm T. E. W. 01992 523 523 info@deltamembranes.com www.deltamembranes.com Delta House, Merlin Way, North Weald, Epping,
More information7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.
Rev. 1 03/05/2015 ANNEX A to the Yokogawa Corporation of America Quality Assurance Manual For Additional Requirements selectively applied to ATEX and IECEx certified products CONTENTS 1. Scope 2. Purpose
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK AMP House Suites 27-29, Fifth Floor Dingwall Road Croydon CR0 2LX Contact: Mr Paul Ward Tel: +44 (0)20 8680 7711 Fax: +44 (0)20 8680 4035
More informationLC2200 Level Controller Installation and Maintenance Instructions
4025250/9 IM-P402-77 AB Issue 9 LC2200 Level Controller Installation and Maintenance Instructions LC2200 ALARM TEST >50% >100%
More informationISO 7779 INTERNATIONAL STANDARD. Acoustics Measurement of airborne noise emitted by information technology and telecommunications equipment
INTERNATIONAL STANDARD ISO 7779 Third edition 2010-08-15 Acoustics Measurement of airborne noise emitted by information technology and telecommunications equipment Acoustique Mesurage du bruit aérien émis
More informationYour specialist partner for total electrical compliance. Electrical Testing
Your specialist partner for total electrical compliance Electrical Testing "To achieve compliance with the legal requirements of the Electricity at Work Regulations 1989 requires proof that an electrical
More informationSECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM
SECTION 40 71 66 ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM PART 1-GENERAL 1.01 SUMMARY A. Ultrasonic clamp-on flow measurement system designed for non-intrusive external to pipe measurement
More informationir-range 8G /03.15 Changes reserved.
U s e r m a n u a l ic-range is-range ir-range 8G.52.80.00/03.15 Changes reserved. Contents 1. Introduction...3 2. Safety...5 3. Boiler description...6 4. Display and functions...7 4.1 DHW and Heating
More informationLoss Prevention Standard
Loss Prevention Standard LPS 1531: Issue 1.1 companies installing or applying passive fire protection This Loss Prevention Standard is the property of BRE Global Ltd. and is made publicly available for
More informationPQS Independent type-testing protocol
PQS Independent type-testing protocol WHO/PQS/FZO2-VP.2 Original: English Distribution: General TITLE: Water-pack freezer: absorption cycle Product verification protocol: E003/FZ02-VP.2 Applies to specification
More informationCALIBRATION HOW IT WORKS
THZ DETECTORS PHOTO DETECTORS HIGH POWER DETECTORS POWER DETECTORS ENERGY DETECTORS MONITORS At Gentec-EO, we understand that the essence of our business since 40 years has been delivering accuracy. There
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61400-11 Edition 2.1 2006-11 Edition 2:2002 consolidated with amendment 1:2006 Wind turbine generator systems Part 11: Acoustic noise measurement techniques Reference number
More informationType: Play house Length: 1195 mm Width: 1195 mm Height: 1740 mm Materials: 18,7 mm laminated wood
Interia Prosjekt AS Attn.: Lars Johansen Olav Tryggvasons Gate 29 N-7011 Trondheim Order no. 654289-6 Appendices 4 Initials laha/prni/hbs Test Report Material: Model: Lavvo Type: Play house Length: 1195
More informationPQS performance specification
PQS performance specification WHO/PQS/E06/TR03.1 Original: English Distribution: General TITLE: Programmable electronic temperature and event logger systems with integral alarm and auto-dialler options
More informationThermohygrometer with Single Type K Input and Superheat Function
User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Thermohygrometer with Single Type K Input and Superheat Function with
More informationDIGITAL CENTRALIZED Section NANOMASKIT
Page 1 of 8 1 GENERAL 1.1 RELATED SECTIONS 1.2 REFERENCES.1 Section 16010 Electrical General Requirements.2 Section 16120 Wire and Cable.3 Section 16993 Electrical Starting and Testing General Requirements
More informationTechnical Note. Noise emission from Dehumidifier Type C35E-3.3 and Type C35E-5.6. TC Project no.: T Page 1 of 10.
Technical Note Noise emission from Dehumidifier Type C35E-3.3 and Type C35E-5.6 Performed for COTES A/S TC-100902 Project no.: T211658 Page 1 of 10 15 January 2016 DELTA Venlighedsvej 4 2970 Hørsholm Denmark
More informationBuilding Standards Division. Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems
Building Standards Division Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems Crown Copyright 2015 Produced by the Buildings Standards Division February 2015 Version
More informationShipboard incinerators with capacities up to 4000 kw
STANDARD FOR CERTIFICATION No. 2.9 Approval Programmes Type Approval Programmes for Marine Equipment Directive (MED) No. 431.90 - MED A.1/2.7 Shipboard incinerators with capacities up to 4000 kw JANUARY
More informationEquipment specifications (D6)
Equipment specifications (D6) This report has been produced for the Cyprus Research Promotion Foundation in fulfilment of deliverable number D6 of the project Advanced Photovoltaics Research and Testing
More informationC-NRPP Quality Assurance Guidance for Radon Test Devices
C-NRPP Quality Assurance Guidance for Radon Test Devices Table of Contents: 1. Purpose 2. Definitions 3. Quality Assurance Plan 4. Calibration 5. Spikes/Performance Tests 6. Duplicates 7. Blanks 8. Cross-Checks
More informationProject demonstrates benefits of traceable on-line measurement of siloxanes in industrial biogas Solving the siloxane measurement problem
Project demonstrates benefits of traceable on-line measurement of siloxanes in industrial biogas Solving the siloxane measurement problem Of all the hurdles the biogas economy has faced, the challenge
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to
More informationCode of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR)
Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR) Contractors Requirements & Competency This section outlines the general Standards
More informationCertificate: / 29 April 2014
Test report: 936/21217455/A of 10 September 2013 Initial certification: 01 April 2014 Expiry date: 31 March 2019 Publication: BAnz AT 01 April 2014 B12, chapter I, No. 1.1 Approved application The tested
More informationPromatrix 6000 I EN de I 1. ISO7240 PAVIRO. Installer checklist
Promatrix 6000 I EN 54-16 de I 1. ISO7240 PAVIRO Eng Installer checklist PAVIRO I ISO7240 Eng I 3 Table of Contents 1. EMERGENY Sound Systems 4 2. List of authorized end-users 5 3. ISO7240 VACIE label
More informationdraft dated 9/17/2015 page 1
247-32 Glare, noise, odor and other nuisances B. Noise 1. Intent Town of Pendleton The Pendleton Town Board determines that the creation of unreasonable noise within the Town limits of Pendleton is detrimental
More informationWORLDWIDE CABLE EXPERTS
WORLDWIDE CABLE EXPERTS An introduction to our cable testing and certification services CORPORATE BROCHURE PAGE I TWO Contents 2 Introducing BASEC 3 What we do 4 Management Systems Certification 5 Product
More informationMatters Needing Attention of Electrical Equipment Installation Engineering in Hazardous Areas. Wang Qiaoli
Matters Needing Attention of Electrical Equipment Installation Engineering in Hazardous Areas Wang Qiaoli Nanyang Explosion Protected Electrical Apparatus Research Institute wqliii@163.com Keywords: hazardous
More informationIEC Functional Safety Assessment
IEC 61508 Functional Safety Assessment Project: Detcon IR-700 Combustible Hydrocarbon Gas Sensor Customer: Detcon The Woodlands, TX USA Contract No.: Q13/06-003 Report No.: DC 13-06-003 R002 Version V1,
More informationCERTIFICATION SAFETY & BEYOND
CERTIFICATION SAFETY & BEYOND Ferhun Emeksiz & R.M ( Max) Bradbury Client Manager & Fire Products Program Manager Global-Mark Pty Ltd Content Product Certification Understanding the framework Fundamental
More informationKA020 Weatherproof Sound Meter Enclosure
KA020 Weatherproof Sound Meter Enclosure The Castle Weatherproof Sound Meter enclosure is designed to make short to medium-term outdoor noise monitoring simple and effective. Dedicated to the Castle SONUS
More informationPPA Michaël GROSSI - FSCE PR electronics
Functional Safety Component selection according to IEC61511 Title 2 Presentation Michaël GROSSI: Ex / SIL Product manager @ Degree in Instrumentation & Measurement More than 10 years experience in Functional
More informationInfrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm
User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature
More informationLeaders in health, safety & environmental consultancy & training
Leaders in health, safety & environmental consultancy & training Training Courses 2016 Courses Accredited Training Classroom Course elearning Course Asbestos Legionella Asbestos Awareness (Category A)
More informationPARKERSTEEL Vauxhall Road, Canterbury, Kent CT1 1HD
PARKERSTEEL Vauxhall Road, Canterbury, Kent CT1 1HD Telephone: 01227 783333 Fax: 0800 521932 E-mail: Sales@Parkersteel.co.uk Steel Stockholders Distributors to Industry Dear Sirs / To Whom it may concern
More informationPAC1500Xi PORTABLE APPLIANCE CHECKER
PAC1500Xi PORTABLE APPLIANCE CHECKER OPERATING INSTRUCTIONS 211A912 CONTENTS 1) Safety... 1 2) Introduction & Description... 2 3) Applications... 2 4) Test Sequence... 3 5) Visual Inspection... 3 6) Earth
More informationCertification Report of the ST 3000 Pressure Transmitter with HART 6
Certification Report of the ST 3000 Pressure Transmitter with HART 6 Revision No.: 2.4 Date: Report Number: 2010-Mar-18 SAS-190/2006T Product: ST 3000 Pressure Transmitter with HART 6 Customer: Order Number:
More informationCertification Report of the ST3000 Pressure Transmitter
Certification Report of the ST3000 Pressure Transmitter Revision No.: 1.0 Date: Report Number: Product: Customer: Order Number: Authority: Responsible: 2006-Dec-12 SAS-128/2006T ST3000 Pressure Transmitter
More informationTECHNICAL MANUAL for FIRE TAPE. E-Z TAPING SYSTEM PO BOX GREEN BAY, WI
TECHNICAL MANUAL for FIRE TAPE E-Z TAPING SYSTEM PO BOX 10887 GREEN BAY, WI 54307 800-721-8273 http://www.e-ztape.com Product Description Fire Tape Manufacturer Alwin Manufacturing Company owns All Products,
More informationGENERATOR SELF-TEST VERIFIER (GSV300) INSTALLATION INSTRUCTIONS
GENERATOR SELF-TEST VERIFIER (GSV300) INSTALLATION INSTRUCTIONS Page 1 GSV300 Installation Manual Rev XC INTRODUCTION The GSV300 is an easy to use, multifunction generator monitor that is packed with useful
More informationTECHNICAL MANUAL for FIRE TAPE. E-Z TAPING SYSTEM PO BOX GREEN BAY, WI
TECHNICAL MANUAL for FIRE TAPE E-Z TAPING SYSTEM PO BOX 10887 GREEN BAY, WI 54307 800-721-8273 http://www.e-ztape.com Table of Contents Product Description...3 Fire Tape Manufacturer...3 Fire Tape Listed
More informationMARCH 2012 ISSUE 2 DYNAMIC. The only electronically controlled Electric Radiator with dynamic looks, dynamic performance and dynamic efficiency.
MARCH 2012 ISSUE 2 DYNAMIC The only electronically controlled Electric Radiator with dynamic looks, dynamic performance and dynamic efficiency. Heatstore has been the driving force in the UK heating market
More informationREAL TIME LABORATORY MONITORING SYSTEM
REAL TIME LABORATORY MONITORING SYSTEM MONITORING LET XILTRIX WATCH OVER YOUR LABORATORY! 20 years experience and IKS expertise makes XiltriX the total monitoring solution for any laboratory. All day,
More informationTechnical reference Reference & design
The requirement for emergency lighting originates from the Fire Precautions Act 1971 and was further enforced by the Fire Precautions (Workplace) Regulations 1997 (Amended 1999). The Regulatory Reform
More informationSpecimen delivery date: Test date: Sampling: The test specimen sampled by customer. Order description N o 152/
CONSTRUCTION OF KAUNAS UNIVERSITY OF TECHNOLOGY SCIENCE LABORATORY OF BUILDING THERMAL PHYSICS BANDYMAI ISO/IEC 17025 Nr. LA. 01.031 Date: 19 of November 2013 Page (pages) 1 (5) Test method: Specimen description:
More informationTempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications
Instruction Manual Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications Manual PCT-3000 Revision 9/2014 The PCT-3000 series control console incorporates
More informationAssessment of the Safety Integrity of Electrical Protection Systems in the Petrochemical Industry
Assessment of the Safety Integrity of Electrical Protection Systems in the Petrochemical Industry 1. Introduction Author: Colin Easton ProSalus Limited ~ Independent Safety Consultants Within the United
More informationZONE MODEL VERIFICATION BY ELECTRIC HEATER
, Volume 6, Number 4, p.284-290, 2004 ZONE MODEL VERIFICATION BY ELECTRIC HEATER Y.T. Chan Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong, China ABSTRACT Selecting
More informationMARINE GYRO COMPASS STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:
STANDARD FOR CERTIFICATION No. 2.9 MARINE GYRO COMPASS JANUARY 2003 Veritasveien 1, N-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD is an autonomous and independent Foundation
More informationCertificate: _01 / 29 April 2014
Test report: 936/21212540/D of 08 October 2013 Initial certification: 05 March 2013 Expiry date: 04 March 2018 Publication: BAnz AT 01 April 2014 B12, chapter I, No. 2.2 Approved application The tested
More informationThird Party Certification:
Third Party Certification: What does it mean for businesses? Introduction If you work in any part of the fire safety industry you will at least have heard of Third Party Certification (TPC) but you may
More informationClimatouch /CT03TS/217S31 Programmable Universal Touch Screen thermostat
Climatouch /CT03TS/217S31 Programmable Universal Touch Screen thermostat Fully configurable 1-4 stages heat/ cool Can be configured for heatpumps, air handlers, oil, gas electric furnaces in any combination
More informationPQS performance specification
PQS performance specification WHO/PQS/E006/TH06.2 Original: English Distribution: General TITLE: Integrated electronic thermometer, with or without alarm function, for vaccine refrigerators and freezers
More informationRADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:
STANDARD FOR CERTIFICATION No. 2.9 RADAR REFLECTOR JANUARY 2003 Veritasveien 1, N-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD is an autonomous and independent Foundation with
More informationFood safety can be measured. Check limit values, ensure quality, comply with HACCP with measuring instruments from Testo.
Food safety can be measured. Check limit values, ensure quality, comply with HACCP with measuring instruments from Testo. Measuring solutions for the food sector Precious goods deserve the greatest care
More informationCastle SONUS GA216I Combined Integrating Sound Level Meter
Castle SONUS GA216I Combined Integrating Sound Level Meter The Castle SONUS range of pocket sized sound level meters bring simplicity and power to the worlds of Noise at Work and Environmental sound monitoring.
More information