GAS LEAK DETECTORS FOR METHANE AND LPG P11 - P12
|
|
- Harvey Underwood
- 5 years ago
- Views:
Transcription
1 GAS LEAK DETECTORS FOR METHANE AND LPG P11 - P12 1
2 Sicurgas P11 and P12 it is a device, that through a sensitive sensor, detects methane gas concentration (P11) and LPG concentration (P12) in domestic environments. Sicurgas P11 and P12 are operating when the gas concentration in the air is much below of the lower explosion limit (L.E.L.). In case of alarm, interferes as well an acoustic and light alarm that is going to prevent the danger. Simultaneously Sicurgas is making the relay to interfere to control the gas interception valve. EXISTS THE POSIBILITY THAT YOU FEEL THE GAS SMEL BEFORE THE DEVICE GIVES AN ALARM SIGNAL. S i c u r g a s I N S T A L L A T I O N ATTENTION gas detector installation is not released from compliance with all rules regarding features, installation and use of the gas appliances, ventilation of the rooms and the discharge of the combustion products prescribed by the EN norms, implementation of the Art. 3 of the law 1083/71 and of the national legislation in force. Before installing the device, it is recommended to read carefully this instruction manual. GREEN LED power supplied device Gas detectors Sicurgas P11 and P12, when are connected to a normally closed (NC) valve with manual reset are giving positive safety. This means that the gas interception valve is closing to interrupt the inflow, as well in case of line voltage absence. For having the maximum security can be used more gas detectors Sicurgas, connected to the same gas interception valve. For e.g. can be mounted a P11 (P12) in the place where is installed the boiler and another one in the kitchen to control the stoves. 1 WALL MOUNTING Sicurgas is supplied with a base suitable for mounting in built-in boxes with 3 modules or in round boxes. Remove the base/cover retaining screw and ease off the cover. Fix the base on the wall (see paragraph 3) or in a built-in box using rear entry for the entries of the connection cables. ATTENTION! Do not open the device, because this may cause electrical shocks or malfunction. B 60 mm A 83,5 mm YELLOW LED defective detector RED LED ALARM - gas concentration is higher than the alarm threshold for built-in boxes 503 A with modules for round built-in B boxes pre-fractured area to increase the space required for wiring fixing srew base-cover After executing the mounting and the connections (see paragraph 4) replace the cover on the base ensuring the two cover pegs are correctly located on the two latching tabs. Screw again the fixing screw and apply in the corresponding place the provided adhesive label indicating the replacement date. 2 e n g l i s h
3 G A S L E A K D E T E C T O R S F O R M E T H A N E A N D L P G 2 SICURGAS PLACEMENT Sicurgas P11 must be fixed on the wall, about 30 cm from the ceiling and at a distance from gas user device, between a minimum of 1 meter and a maximum of 4 meters, in such position as to allow natural air circulation. max. 30 cm S i c u r g a s P11-P12 min. 1 mt max. 4 mt 3 4 Sicurgas P12 must be installed approximately 2 meters (minimum 1m maximum 4m) from the gas user device and about 30 cm from the floor. ELECTRICAL CONNECTIONS Sicurgas P11 is already equipped with two internal alarms: one visible and one acoustic. Just connect the line 230V c.a. 50Hz to the terminals 4 and 5 to ensure the gas presence signaling in the environment. It is recommended to use a valve with manual reset to stop the gas supply when there is an alarm situation. The internal relay can control all kind of power supplied valves with manual reset: normally closed (NC), always power supplied, which require a commutating stable relay; normally opened (NO), which require an impulse relay. Relay operating mode can be chose in the installation moment, by moving a switch (JP6) on the printed circuit, normally supplied for functioning with stable relay for NC valves (down switch). min. 1 mt max. 4 mt max. 30 cm ATTENTION! DO NOT place the device behind or under cabinets or shelves that are not allowing the natural air circulation in environment. DO NOT place it near aerators (minimum distance 2 meters). DO NOT place it on the vertical bakery surfaces, steam sources, in places where can be achieved by splashing water, near sinks, etc. Do not place where environmental conditions are different from the prescribed operation conditions. switch JP6 in down position (B) EXAMPLES OF CONNECTION predisposed in the factory stable relay for normally closed NC valves with EXAMPLE OF CONNECTION with stable relay, manual reset always power supplied, to control a normally closed valve with manual reset (down switch). GPL switch JP6 in up position (A) impulse relay for normally opened NO valves with manual reset The system guarantees maximum safety, the gas inflow will be stopped in case of: gas concentration threshold exceeding; power supply lack of the valve only or of the detector; connection breakdown between the detector and the valve. L N NC possible external alarm For device power supply, connect the terminals 4-5 to the circuit 230V-50Hz. e n g l i s h 3
4 S i c u r g a s O P E R A T I O N IMPULSE RELAY, with current activation, to control a normally opened valve with manual reset (switch in up position) The connection will ensure the interruption of the gas inflow in case of gas concentration threshold exceeding. L N NA USING MORE sicurgas UNITS TO CONTROL SEVERAL ROOMS WITH ONE GAS VALVE Example of connection for several Sicurgas detectors with stable relay that controls the same normally closed valve NC and an external alarm. The contacts must be connected in series. Example of connection for several Sicurgas detectors with impulse relay which controls the same normally opened valve NA. The contacts must be connected in parallel. L N L N NA OPERATION 5 6 PLUG IN THE POWER SUPPLY (230Vc.a. 50Hz). At the first detector switch-on and after any power supply failure, Sicurgas enters into pre-heating and a sensor stabilization phase that continues maximum 3 minutes. During this period will flash alternately the red and green led indicating that the device is not ready yet for gas detection. After this period just the green led will remain switched on. DEVICE CONTROL AND SILENCING alarm test/ silencing key (cord for P11) Sicurgas is provided with a TEST/SILENCING key, that allows to check the installation or to inhibit the alarm. This key is activated through a cord for P11 methane gas (installed about 30 cm from the ceiling) or through a button located on the body of P12 LPG (installed about 30cm from the floor). To test the installation press the TEST/SILENCING key for 10 sec. In this way will be activated a control procedure of about 30 sec., during which will be checked installation components. Alarm inhibition is used instead to avoid an involuntary intervention of the detector, in fact Sicurgas sensor, as all available on the market sensors, while being very selective can also participate for other substances, for example: alcohol vapors, wine etc. For example, during the use of wine while preparing food is possible, that the detector will enter in alarm situation. To avoid this inconvenience press the TEST/SILENCING key for approx. 3 sec. After having pressed the silencing key, for 10 minutes we will have a non-alarm situation: the buzzer does not emits acoustic signaling, the relay returns in non-alarm position and the red and green led, are flashing alternately to indicate the silence period; acting again on the switch during 10 minutes of the silence period, the detector will immediately resume the normal operation. 4 e n g l i s h
5 O P E R A T I O N H O U R S Intellitherm O P E R A T I O N After 10 minutes, the detector resumes automatically the normal operation. Here is possible, knowing that can be used substances which can cause a false alarm, to reduce in advance detector s sound to prevent the signalizations and gas shut off of the stoves (due to gas valve intervention). Some of the most common substances that can cause false alarm are the following: wine - liquors - alcohol - deodorants - stain-removers - varnish thinners - hair spray - excessive steam. Sicurgas also allows to set the type of the acoustic alarm, see picture on the side. intermittent SOUND switch JP3 in up position (A) continuous sound switch JP3 in down position (B) 7 maintenance AND CLEANING Pay attention to temperature values or to the extreme humidity. To give the maximum security the detector must be constantly powered. For routine maintenance and for the temporary closing-down of the device, it is recommended to contact an authorized technician. Regularly check the correct operation using the appropriate button or a gas test. Other test methods may damage the equipment. To clean the unit, use a soft cloth without using chemical cleaners or solvents. ATTENTION! in case of alarm: 1. turn off all opened flames in the room. 2. close the tap of the gas meter or of the L.P.G. gas cylinder. 3. do not switch on or off lights, do not operate electrical equipments or other electrically operated devices. 4. open the windows and the doors to raise the ventilation inside the room. 5. do not use telephones in the room where you suspect gas presence. If the alarm stops it is necessary to identify the matter that caused it and act accordingly. If the alarm continues and the gas leak cannot be identified or cannot be eliminated leave the room and from outside call the emergency services. T E C H N I C A L F E A T U R E S Device of A type. Shockproof insulating material casing. Protection degree: IP42. Operating ambient temperature / humidity: from 10 to 40 C, max. 90 UR%. Power supply: 230Vc.a. 50Hz. Consumption: 4 VA. Sealed relay to avoid sparks during switching. Maximum power of the controlled valve: 450VA at 230Vc.a. 50Hz. e n g l i s h Contacts rating: 6(2)A / 250Vc.a. Switch for choosing functioning relay mode, stable or impulse. Semiconductor sensor for gas detection. Internal visual and acoustic alarms. Intervention threshold volumetric value: (% L.I.E.) 9% for methane. (% L.I.E.) 10% for LPG. In compliance with the standard EN
6 S i c u r g a s n o t e S 6
7 S i c u r g a s P11-P12 7
8 _GB TO BE COMPLETED BY THE INSTALLER Installation date Installation place Identification code/manufacturing date (the code is indicated inside the cover) Sensor replacement date (sensor replacement date is indicated on the front cover label) N.B. THE DETECTOR HAS TO BE REPLACED AFTER A PERIOD OF FIVE YEARS FROM THE INSTALLATION DATE STAMP AND SIGNATURE OF THE INSTALLER FANTINI COSMI S.p.A. Via dell Osio, Caleppio di Settala, Milano Tel Fax info@fantinicosmi.it supportotecnico@fantinicosmi.it w w w. f a n t i n i c o s m i. i t
9 Sicurgas P13 CO carbon monoxide detector with electrochemical cells for domestic use Sicurgas P13 should be ideally installed in bedrooms or in premises with more frequent occupancy. For a correct operation it must be installed close to the occupants breathing at a height ranging between 0,8 and 1,2 meters from the floor away from any object or walls limiting the air circulation Dimensions (mm) 86 Gas type Power supply Contacts rating Test button Operating temperature Protection degree P13 CO carbon monoxide 230Vca - 50Hz 6(2)A - 250Vca yes C IP42 ELECTRICAL CHARACTERISTICS Power supply: 230Vca 50Hz. Consumption: 4 VA. Output through electromagnetic relay. Contacts rating: 6(2)A - 250Vca. STANDARDS AND APPROVALS In conformity with EN INSTALLATION Mounting in built-in 3-module boxes, on the wall or in round boxes. Mounting hole suitable for built-in 3-module boxes. 83,5 mm 60 mm 42
10 The detector should be fixed on the wall at a height of approximately 1,20 mt from the floor. For a correct functioning of Sicurgas P13, avoid installing the device: behind or under cabinets or shelves that can prevent the natural air circulation in the room; near air conditioning systems (minimum distance 2 meters); on the vertical line of cooking units or steam sources (bathtubs, etc.); in places, that could be reached by spraying water, near sinks, showers, etc. 0,8 1,2 mt OPERATION Sicurgas P13 detects CO carbon monoxide through its electrochemical cells probe in domestic environments. CO carbon monoxide is a dangerous gas due to the fact that it s inodorous and colourless. In case of very high concentration it could lead to death. Sicurgas P13 helps detecting CO leaks, however it cannot prevent chronic effects caused by prolonged exposition to CO. Sicurgas P13 operates depending on the CO concentration in the environment according to the norm EN 50291, as follows: 50 ppm: alarm ON with 60 to 90 minutes exposure 100 ppm: alarm ON with 10 to 40 minutes exposure 300 ppm: alarm ON with 3 minutes exposure In case of alarm an acoustic and luminous signal turns ON to warn about the danger. At the same time Sicurgas P13 activates a relay that operates a valve or a ventilation system. TEST BUTTON Sicurgas P13 is equipped with a TEST button to verify that the system operates properly. The test button can be enabled by pressing in the low part of the product as shown in the drawing. To run the TEST properly press the button until a buzzer is activated (yellow and red LED flash alternately, green LED is on). The device goes back to normal functioning after 30 seconds. P Some substances could create a blind alarm, such as alcohol, deodorants, stain removers, paint thinners, hair sprays, trichloroethylene. Sicurgas P13 is equipped with a luminous and an acoustic alarm. Electrical wiring as shown in the drawing to install properly the device and connect it to a NC valve or a ventilation system. TECHNICAL FEATURES Spare catalytic sensor to detect CO carbon monoxide. Shock proof body. Internal luminous and acoustic alarms. 3 warning LED: Green LED: the device works properly Yellow LED: malfunction Red LED: ALARM, CO carbon monoxide is being detected Sensor life: 5 years from the production date (see replacement date on the device). The relay of the device is a sealed type and filled with inert gas that guarantees the absence of sparks when commuting. ACCESSORIES S80 Acoustic and light signalling device. 43
GAS LEAK DETECTORS FOR METHANE AND LPG P11 - P12
GAS LEAK DETECTORS FOR METHANE AND LPG P11 - P12 1 Sicurgas P11 and P12 it is a device, that through a sensitive sensor, detects methane gas concentration (P11) and LPG concentration (P12) in domestic
More informationCOSTER. Code Internal Alarm Pre-alarm Suitable sensor threshold threshold external sensor
G - RGS 8-8 Eng. 5..08 MZ REV. 0 DOMESTIC MICROPROCESSOR- BASED SELECTIVE DETECTORS WITH RELAY OUTPUT G 5..08 MZ REV. 0 RGS 8-8 Eng. Conform to standards: CEI EN 5094 and CEI EN 5044 for combustible gases
More informationGL-CO-RFG Channel Gas Leak Alarm System
Four Elms Road Edenbridge Kent TN8 6AB UK Features & Benefits Remote sensors for natural gas, LPG and CO 1 x SPST relay outputs DIN-rail as standard, panel mounting kit available Adjustable alarm thresholds
More informationA series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.
Belonging to Made in Italy GS911K Gas Detector GS911K Using the catalytic sensor inside it, the GS911K detector detects the presence of explosive gas such as: Methane, LPG, with trip sensitivity calibrated
More informationElectronic control unit for gas leak detection with 4 detection zones
P82 Electronic control unit for gas leak detection with 4 detection zones Electronic control unit for gas leak detection in industrial environment, suitable for controlling and signaling dangerous gas
More informationTECHNICAL CATALOGUE GAS LEAK DETECTOR AND SOLENOID SAFETY VALVES
TECHNICAL CATALOGUE GAS LEAK DETECTOR AND SOLENOID SAFETY VALVES TEC ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings
More informationSetup instructions. Honeywell GAS DETECTOR. Overview. Accessories The instruction x1 Plug dowel x2 Screw x2 Double-sided adhesive tape x2
Setup instructions 1. Connection terminal, output signal and device connection Honeywell GAS DETECTOR Overview The autonomous gas sensor (hereinafter referred to as the sensor) is a home device for detecting
More informationCHCO Double Gas Detector
Belonging to Made in Italy HO Double Gas Detector HO The HO Detector has been designed and built according to European regulations to detect the presence of toxic and explosive gas. A microprocessor is
More informationDanfoss gas detection units
Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning
More informationBS-316. Gas detection control panel up to 16 inputs. Installation operation manual
BS-316 Gas detection control panel up to 16 inputs Installation operation manual Page 1 from 21 Contents 1 Operation instructions--------------------------------------------------------------------------------------------------------------------3
More informationAmmonia Leak Detector Manual
Ammonia Leak Detector Manual Document No. 70-PHW-1023-R2.5 No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical,
More informationWarranty Registration
WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free from defects in workmanship and materials for a period
More informationGas leak detection system. for heating rooms and similar environments. Description. Sensor for methane gas IP44. Sensor for LPG gas IP44
s 7 603 INTELLIGAS Gas leak detection system for heating rooms and similar environments Electronic control unit for gas leak detection with up to 4 sensors aimed to drive one or two gas flow cut-off 12VD
More informationGAS MONITOR Model Model
Sierra Monitor Corporation 1991 Tarob Court, Milpitas, CA 95035 (408) 262-6611 (800) 727-4377 (408) 262-9042 - Fax E-mail: sierra@sierramonitor.com Web Site: www.sierramonitor.com GAS MONITOR Model 2350-00
More informationKAE Gas Alarm Operation Manual
KAE Gas Alarm Operation Manual Henan Hanwei Electronics Co.,Ltd ISO9001-2008 Precautions: To avoid personal safety injury, Instrument damage and potential dangerous accident; do not use gas detector before
More information(CH 4 ) METHANE GAS DETECTOR AE09/GM, AE09/GM-12, AE09/GM-24
(CH 4 ) METHANE GAS DETECTOR AE09/GM, AE09/GM-12, AE09/GM-24 Microprocessed gas detector, designed according to Regulation UNE-EN 50194, allows for METHANE gas detection (natural or town gas). The detector
More informationN L L1 C NC 230V MULTI-ZONE WIRELESS CLIMATE CONTROL SYSTEM CH175
N L L1 C NC 23V MULTI-ZONE WIRELESS CLIMATE CONTROL SYSTEM CH175 EVERY ROOM HAS THE RIGHT TEMPERATURE AND HUMIDITY With Intellicomfort + you can adjust the room temperature and humidity differently, in
More informationMacurco HD-11 Hydrogen Gas Detector
Macurco HD-11 Hydrogen Gas Detector User Instructions Important: Keep these User Instructions for reference TABLE OF CONTENTS GENERAL SAFETY INFORMATION 3 Intended Use 3 List of Warnings and Cautions 3
More informationGS100M Gas Detection Controller
GS100M Gas Detection Controller GS100M 1 Zone Gas Detection Controller 1 Zone / Sensor Conventional Positive Safety IP44 EN61010-1 EN50270 FEATURES Single Zone Protection Positive Safety Option Detection
More informationGS100M Gas Detector. Technical Specification
GS00M Detector Application Duomo is recognised within the Gas industry for providing a comprehensive range of low cost, high reliability gas detection for many applications. We have installed and commissioned
More information169MHz Telecare Devices Gas & Carbon Monoxide Detector
169MHz Telecare Devices Gas & Carbon Monoxide Detector Compatible with Reach at-home alarms, Advent xt warden call, Altec Response and Touchsafe Pro Nursecall systems Gas alarm activates at 10% of Lower
More informationModel LP USER S MANUAL AND INSTALLATION INSTRUCTIONS
Atwood Mobile Products LLC 1120 North Main Street Elkhart, IN 46614-3203 USA & Canada 1-866-869-3118 Internet: http://www.atwoodmobile.com Model LP USER S MANUAL AND INSTALLATION INSTRUCTIONS TESTED TO
More informationMacurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference
Macurco HD-11 Hydrogen Gas Detector User Instructions Important: Keep these User Instructions for reference 2 TABLE OF CONTENTS GENERAL SAFETY INFORMATION 4 INTENDED USE 4 LIST OF WARNINGS AND CAUTIONS
More informationThe guarantee on this appliance is valid for 12 months from the first day of installation.
Users Manual Dear Customer, Thank you for choosing an ARISTON boiler. We guarantee that your boiler is a reliable and technically sound product. This Users Manual provides detailed instructions and recommendations
More informationInstructions for Use and Warranty Details. RH17-900mm Island Canopy Rangehood
Cooking c o l l e c t i o n Instructions for Use and Warranty Details RH17-900mm Island Canopy Rangehood C ongratulations on the purchase of your new appliance. This appliance has been designed and manufactured
More informationSafety Siren. Owner's Manual. Family Safety Products Inc. Carbon Monoxide, Propane & Methane. Model Number HS80004 HS80104 HS80204 HS80504 DETECTOR
Safety Siren Carbon Monoxide, Propane & Methane DETECTOR Owner's Manual Model Number HS80004 HS80104 HS80204 HS80504 Copyright, 1996 All Rights Reserved Family Safety Products, Inc. 2879 Remico SW Grandville,
More informationSPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System
SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM User Instructions For The Model 5200 Gas Monitor System To completely customize the specifications to your exact application, modifications to the following
More informationInstallation & User Manual DURAUTO. Domestic Gas Detector
Installation & User Manual DURAUTO Domestic Gas Detector 1. PRESENTATION DURAUTO is a microprocessed wall mounted detector available in 12V CC/ 230V AC and 2 different versions: Natural Gas and Butane/
More informationGas Safety Products. Installation, operating and maintenance. Merlin Gas Detectors. Merlin Gas Detectors. Rev: 09 Date: Product Data Sheet
Gas Safety Products Merlin Gas Detectors Installation, operating and maintenance Read these instructions carefully before operating or servicing Rev: 09 Date: 19-01-18 1 The unit should be installed by
More information6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment
CONTENT Page 1. GENERAL INFORMATION ------------------ 2 2. FEATURES ---------------------------------------- 2 3. SPECIFICATION --------------------------------- 3 4. OPERATION GUIDE ---------------------------
More informationMO n : 12JMC rév A
CTT8 MO n : rév A Page 2 / 18 MODIFICATIONS Rev. Description Date Checked by Approuved by Z Creation 2012/02/12 JMC LA A First issue 2012/02/14 JMC LA INDEX Page 3 / 18 GENERALITY 4 INTRODUCTION 4 ACCESSORIES
More informationZareba Metro Gas Detector
Zareba Metro Gas Detector The Metro addressable gas detector enables remote monitoring of flammable and toxic gas hazards Metro Gas Detector One-Stop Shop Flammable and toxic gas monitors available Methane,
More informationIntroduction Carbon monoxide (CO) is a colorless, odorless and tasteless gas which is toxic and can quickly become a mortal danger. Amongst others, ca
Art.-Nr./No art 51111 CO alarm Carbon monoxide detector User Manual EN 50270 Important Prior to using the device for the first time, carefully and completely read through all operating instructions. Keep
More informationTEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.
TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL Microener- Copyright 2010 FW 2.1 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection
More informationDanfoss gas detection units
Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning
More informationUPON COMMENCMENT OF INSTALLATION IT IS OF PARAMOUNT IMPORTANCE THAT THE STEP BY STEP GUIDE (INCLUDED) IS FOLLOWED COMPLETELY
Important UPON COMMENCMENT OF INSTALLATION IT IS OF PARAMOUNT IMPORTANCE THAT THE STEP BY STEP GUIDE (INCLUDED) IS FOLLOWED COMPLETELY UPON COMMENCMENT OF INSTALLATION IT IS OF PARAMOUNT IMPORTANCE THAT
More informationQD6310. Fixed Gas Detector Operation Manual
QD6310 Fixed Gas Detector Operation Manual Safety Information Before using the device, please first carefully read and follow the following information to operate the device: Please don't use the defective
More informationNG-9B NATURAL GAS ALARM
User Manual NG-9B NATURAL GAS ALARM Detects gas from household appliances NG-9B 1 Do not ignore any warning from your Natural Gas Alarm! Vacate the property and immediately call the UK Gas Emergency Service
More informationKAB Gas Alarm Operation Manual
KAB Gas Alarm Operation Manual Henan Hanwei Electronics Co.,Ltd ISO9001-2008 Precautions: To avoid personal safety injury, Instrument damage and potential dangerous accident; do not use gas detector before
More informationEXPLOSION-COUNTERACTING SYSTEM «UDAR-KB» Installation Guide
EXPLOSION-COUNTERACTING SYSTEM «UDAR-KB» Installation Guide Introduction Explosion-counteracting system «Udar-KB» (hereinafter, Udar-KB) is designed for counteracting gas-explosion attacks against ATMs
More informationCooking c o l l e c t i o n
Cooking c o l l e c t i o n Instructions for Use and Warranty Details RH60-600mm Fixed Rangehood RH90-900mm Fixed Rangehood ongratulations on the purchase of your new C appliance. This appliance has been
More informationLS1. Operator Manual. Kane International Ltd
LS1 Operator Manual Kane International Ltd Kane House, Swallowfield Welwyn Garden City Hertfordshire, AL7 1JG Tel: +44 (0) 1707 375550 Fax: +44 (0) 1707 393277 E-mail: sales@kane.co.uk www.kane.co.uk Stock
More informationUSER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -
USER GUIDE DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER - II CONTENTS 1. SYMBOLS AND WARNINGS... 5 2. GENERAL INFORMATION... 6 3. WARNINGS... 7 4. GENERAL DESCRIPTION... 8 5. INSTALLATION...
More informationBX444-M Gas Detector. Features. Application. Operation
BX-M Gas Detector Application Duomo is recognised within the gas industry for providing a comprehensive range of low cost, high reliability gas detection for many applications. We have installed and commissioned
More informationWIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions
Wireless Gas Detection & Shut Off System - User Manual & Instructions Please read and follow these instructions prior to installation of the system as correct installation is critical to the performance
More informationMulti Channel Gas Detection System AGDS MC. The Home of Control & Automation in Ireland
Multi Channel Gas Detection System AGDS MC The Home of Control & Automation in Ireland Multi-channel Gas Detection System The AGDS-MC, Gas detection system has been designed for use in boiler houses and
More informationBX444-Mc Gas Detector
Installation and User Guide Rev.01. BX444-Mc Gas Detector Application Duomo is recognised within the gas industry for providing a comprehensive range of low cost, high reliability gas detection for many
More informationUser Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.
User Manual for model FLOWMAX-90 Condensing water heater 85,000 BTU WARNING If the information in these instructions is not followed exactly, a fire or explosion may result, causing property damage, personal
More informationControl Unit BX280 CONFORMITY EN EN EMC EN Isntallation and user Guide. Firmware Version 9.0
Belonging to ontrol Unit BX280 Through the connection of 2 remote probe, the BX280 control unit has been designed and built according to European regulations to detect the presence of toxic and/or explosive
More informationEUROFLAT SERIES TYPES C... S... M...
EUROFLAT SERIES TYPES C... S... M... AUTOMATIC CONTROL SYSTEMS FOR GAS BURNERS AND GAS BURNING APPLIANCES WITH OR WITHOUT FAN APPLICATION The electronic systems of this range are suitable to control gas
More informationCORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation
CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD Corona Corporation This instruction manual contains important information for safe use of this device. Keep this instruction manual
More informationUser Manual 120/240/300 Outdoor Motion Detector
User Manual 120/240/300 Outdoor Motion Detector Swiss Garde 4000 Warning! - Any work on the main power supply must only be completed by trained specialists. - The product must be installed in accordance
More informationRefrigerant Leak Detector Manual
Refrigerant Leak Detector Manual Document No. 70-PHW-1018-R2.4 No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical,
More informationCooker Hood LA-72-CAN.
Cooker Hood LA-72-CAN EN www.luxairhoods.com WARNINGS Safety This equipment can be used by children aged 8 or more, people with physical, mental and sensory disabilities or inexperienced users it they
More informationModel GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com
Model GD-3300 Combustible Gas Leak Detector Instruction Manual reedinstruments com Introduction The Combustible Gas Leak Detector has a 16 gooseneck probe to find leaks in hard-to-reach areas. It s adjustable
More informationTECHNICAL AND OPERATION DOCUMENTATION
TECHNICAL AND OPERATION DOCUMENTATION 8 201 DE-TOX Carbon monoxide detector GDC.2 (power 230V/12V) CONTENTS 1. Technical parameters 2. Description 3. Operating method 4. Installation 5. Connecting to plant
More informationGAS-Mate. Combustible Gas Leak Detector
O P E R A T I N G M A N U A L GAS-Mate Combustible Gas Leak Detector Declaration of Conformity This is to certify that this equipment, designed and manufactured by INFICON Inc., 2 Technology Place, East
More informationTHC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER
THC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2000 Conforms to / Conforme à ANSI std Z83.7 2000 Suitable for indoor or outdoor installation / Unvented / Unattended
More informationRemote alarm unit Art. Nr.:
Art. Nr.: 0814.. Product features Indication and transmission of alarms, malfunctions, battery status for all programmed alarm detectors Remote alarm programming of up to 20 alarm detectors Function monitoring
More informationSmoke Alarm User s Manual
V-MUL-007-D(A0) Smoke Alarm User s Manual Please read and save this manual PHOTOELECTRIC SMOKE ALARM( HUSH FEATURE) MODEL: VST-S588H Class II Apparatus Photoelectric smoke alarms are generally more effective
More informationCTT8 TEMPERATURE MONITOR DEVICE
INSTRUCTION MANUAL IM302-U v2.3 CTT8 TEMPERATURE MONITOR DEVICE GENERALITY The device of control temperatures CTT8 is used in the control of electric machine, transformer, motor, etc. where it s possible
More informationMST, INC. MODEL 2002 CARBON MONOXIDE MONITOR OWNER S MANUAL
MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR OWNER S MANUAL IMPORTANT WARNING WHEN THE CO MONITOR IS CORRECTLY INSTALLED AND MAINTAINED, IT MONITORS THE LEVEL OF CARBON MONOXIDE IN THE RESPIRATORY AIR
More informationCarbon Monoxide (CO) Detecting Ventilation Fan Controller Model COSTAR 24VC-e Single Relay
Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model COSTAR 24VC-e Single Relay Part No. 905-0000-09 Replacement Sensor Module is Part Number 905-0001-09 1. INTRODUCTION Your COSTAR 24VC-e carbon
More informationFour Channel Gas Detection System AGDS 4. The Home of Control & Automation in Ireland
Four Channel Gas Detection System AGDS 4 The Home of Control & Automation in Ireland Four Channel Gas Detection System The AGDS-4, Gas detection system has been designed for use in boiler houses and plant
More informationNGD8800 USER S MANUAL
NGD8800 USER S MANUAL COMBUSTIBLE GAS DETECTOR Please read this manual carefully and thoroughly before using this product. CONTENT Page 1. GENERAL INFORMATION ------------------ 2 2. FEATURES -----------------------------------------
More information169MHz Telecare Devices Carbon Monoxide Detector
169MHz Telecare Devices Carbon Monoxide Detector Compatible with Reach at home alarms, Advent xt warden call, Altec Response and Touchsafe Pro Nursecall systems CO alarm activates on Time Weighted Average;
More informationGas Safety Products. Installation, operating and maintenance. Merlin Gas Detectors. Read these instructions carefully before operating or servicing.
Gas Safety Products Merlin Gas Detectors Read these instructions carefully before operating or servicing. Installation, operating and maintenance S&S Northern Ltd 1 The unit should be installed by a competent
More informationCARBON MONOXIDE DETECTOR, i4h-co-m330
CARBON MONOXIDE DETECTOR, i4h-co-m330 Alarm LED Power LED Fault LED Air Vents Test/Mute Button Press the latch and push the cover downward to open the battery compartment INTRODUCTION The i4h-co-m330 electrochemical
More informationDräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors
Dräger Polytron 5700 Fixed Gas Detector Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Including e-box for increased safety wiring The Dräger
More informationPR5. INSTRUCTION MANUAL IM846-U v0.4
INTRUCTION MANUAL IM846-U v0.4 REMOTE IGNALLING AND CONTROL PANEL to join to the following devices for the permanent insulation control: HRI-R40 HRI-R22t HRI-R22 HRI-R24 HRI-R24N GENERAL The remote signalling
More informationDigital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6
Digital Gas Transmitters with Auxiliary s & Control Specifications subject to change without notice. USA 181011 Page 1 of 5 DESCRIPTION Digital RS-485 communicating, addressable toxic and combustible gas
More informationINSTRUCTION AND MAINTENANCE MANUAL DRYERS A 11 - A 12 - A 13 - A 14 (R410A)
Code 007806 0 Edit. 0/04 INSTRUCTION AND MAINTENANCE MANUAL DRYERS A - A - A - A 4 (R40A) READ THIS MANUAL CAREFULLY BEFORE CARRYING OUT ANY OPERATIONS ON THE DRYER. Cod. 007806 0 - Edition 0/04 - CONTENTS
More informationUBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1
U S E R M A N U A L UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1 0359 18 UBS1RF Optical Smoke Alarm OverView This optical smoke alarm is a fire detection and alarm device which gives
More informationCOMBY 4000 & 9000 STEAM CLEANER OPERATOR MANUAL
COMBY 4000 & 9000 STEAM CLEANER OPERATOR MANUAL Clemas & Co. Unit 5 Ashchurch Business Centre, Alexandra Way, Tewkesbury, Gloucestershire, GL20 8NB. Tel: 01684 850777 Fax: 01684 850707 Email: info@clemas.co.uk
More informationOperating instructions
Operating instructions For the operator Operating instructions HOME SYSTEM GB, IE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Tel. +49 21 91 18 0 Fax +49 21 91 18 28 10 info@vaillant.de
More informationSMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS
SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS CONTENTS 1. INTRODUCTION... 5 2. WARNINGS... 6 3. GENERAL DESCRIPTION... 7 4. INSTALLATION... 8 5. LUMINOUS INDICATORS AND COMMANDS... 9 6. DIP-SWITCH
More informationRenew the air, prevent mold and save energy! ASPIRVELO AIR ECOCOMFORT
Renew the air, prevent mold and save energy! ASPIRVELO AIR ECOCOMFORT The most complete range of single-room HRU DAMP SMELLS MOLD EXHAUST AIR ASPIRVELO AIR ECOCOMFORT Prevent unwanted mold and damp saving
More informationCH193 WiFi PROGRAMMABLE THERMOSTAT WHENEVER WHEREVER CONNECTED. Intelliclima+
CH193 WiFi PROGRAMMABLE THERMOSTAT WHENEVER WHEREVER CONNECTED Intelliclima+ WHENEVER WHEREVER CONNECTED Intellitouch CH193WiFi is the new programmable thermostat that controls heating and cooling systems
More informationTHC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER
THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2000 Conforms to / Conforme à ANSI std Z83.7 2000 Suitable for indoor or outdoor installation / Unvented / Unattended
More informationSENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector
SENSIT HXG-2 Instruction Manual For use with combustible gases Gas Leak Detector CLASSIFIED 7WA6 Approved UL913, For Class 1, Division 1, Groups C & D hazardous locations when used with alkaline batteries.
More informationUSERS MANUAL FOR GAS BOILERS
USERS MANUAL FOR GAS BOILERS PLEASE READ THE MANUAL CAREFULLY: IT CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, INSTALLATION, USE AND MAINTENANCE OF THE APPLIANCE MODELS: NOVADENS 24 NOVADENS 24C NOVADENS
More informationGas Safety Products. Installation, operating and maintenance 10/12/2017. Merlin Gas Detectors. Merlin Gas Detectors. American Gas Safety LLC 1
Gas Safety Products Merlin Gas Detectors Installation, operating and maintenance 10/12/2017 American Gas Safety LLC 1 Table of contents 1 General information... 3 2 Installation... 3 2.1 Mounting the Merlin
More informationTC100N. Fixed Gas Detector Operation Manual
TC100N Fixed Gas Detector Operation Manual Safety Information Before using this device, please carefully read the following safety information: After opening the packing box, please check if there is any
More informationMST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL
MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL IMPORTANT WARNING WHEN THE CO MONITOR IS CORRECTLY INSTALLED AND MAINTAINED, IT MONITORS THE LEVEL OF CARBON MONOXIDE IN ITS SURROUNDINGS..
More informationUSER MANUAL 03-0_MOD-KH1203US_H5_H5.indb _MOD-KH1203US_H5_H5.indb /11/08 21:28: /11/08 21:28:13
USER MANUAL 2 Safety Information Before use, be sure to carefully read all information to ensure that you use this product correctly. Always follow this information when using this unit. WARNING Do not
More informationCopying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.
Installation manual detector and controller Code no. 20711062 Page 1/30 CONTENTS Controller... 2 Function of the Relays... 2 Gas Detectors... 2 Cabling... 4 Mechanical Installation of the gas detectors...
More informationRegister your product and get support at. AC4076. User manual
Register your product and get support at www.philips.com/welcome AC4076 User manual 2 1 3 4 English Introduction Congratulations on your purchase and welcome to Philips! To fully benefit from the support
More informationEclipse Self-Check UV Scanner
856 Instruction Manual 10/18/2010 Eclipse Self-Check UV Model 5602-91 Version 1 Introduction The self-check UV is used for continuous gas or oil flames. A mechanical shutter in the scanner closes briefly
More informationOperation and Maintenance Manual
Operation and Maintenance Manual GDS-48 Remote Bridge Sensor for Combustible Gases AUTHORIZED DISTRIBUTOR: GasDetectorsUSA.com - Houston, Texas USA sales@gasdetectorsusa.com - 832-615-3588 CAUTION: FOR
More informationtesto 316-EX gas leak detector Instruction manual
testo 316-EX gas leak detector Instruction manual 2 1 Safety and the environment 1 Safety and the environment 1.1. About this document Use > Please read this documentation through carefully and familiarize
More informationPioneer-R16 Gas Monitor Operator s Manual
Pioneer-R16 Gas Monitor Operator s Manual Edition 7/2/97 RKI INSTRUMENTS, INC RKI Instruments, Inc. 33248 Central Ave, Union City, CA 94587 (510) 441-5656 Chapter 1: Description About the Pioneer-R16 Gas
More informationFlame Safeguards LFE10. Building Technologies HVAC Products
7 71 Flame Safeguards LAE LFE Flame safeguards for burners with intermittent operation The LAE is used for the supervision and indication of oil flames The LFE is used for the supervision and indication
More informationEUROBOX SERIES TYPES CM... SM... MM...
EUROBOX SERIES TYPES CM... SM... MM... AUTOMATIC GAS BURNER CONTROL SYSTEMS FOR GAS BURNERS AND GAS BURNING APPLIANCES WITH OR WITHOUT FAN Application This range of electronic gas burner control systems
More informationJUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS
JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS Before using the heater, read and understand all instructions and follow them carefully. The manufacturer is not responsible for damages to goods
More informationModel C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments
Model C-380 Refrigerant Leak Detector Instruction Manual reedinstruments www 1-877-849-2127 info@reedinstruments. www.reedinstruments. Table of Contents Safety... 3 Features... 3 Specifications... 4 Instrument
More informationLFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02
7 783 ISO 9001 DETACTOGYR Flame Safeguard Series 02 The... together with the QRA50M / QRA51M form a self-checking flame supervision system (DETACTOGYR ) designed for use with continuously operating oil
More informationThe device is not suitable for continuous operation, but only for short-time operation (note lifetime of battery).
User s Manual Gas-Leak Detector Introduction Dear customer, We would like to thank you for your acquisition of the Gas-leak detector. You have acquired a product which is built to the latest and highest
More informationMODEL: SP12C7. (Portable 4 gas detector) Operating Manual
MODEL: SP12C7 (Portable 4 gas detector) Operating Manual Guarantee and Repair Senko Co., Ltd. guarantees the products of SP series for 24 months from the shipping date and repairs or replaces the defected
More informationGS100M Gas Detector. Features. Application. Operation
GS00M Gas Detector Microprocessor control Wall or panel mounted zone protection 4-20mA signal input Measuring range 0-20% L.E.L. / 0-300ppm P44 protective rating EN5094 for explosive gases EN5029 for toxic
More informationMacurco CM-E1 Carbon Monoxide Detector
Macurco CM-E1 Carbon Monoxide Detector User Instructions Important: These User Instructions are to be provided to the homeowner/end user upon product installation. Each person installing or using this
More information