Fill Point, Level Gauges, and Control Range

Size: px
Start display at page:

Download "Fill Point, Level Gauges, and Control Range"

Transcription

1 Fill Point, Level Gauges, and Control Range Page 1

2 Contents Fill Points, Level Gauges, and Control Equipment... 3 Fill Point Cabinets... 4 Single Tank Cabinet... 5 Twin Tank Cabinet... 6 Three Tank Cabinet... 7 Typical Fill Valve Assembly... 8 Tank Overfill Alarm... 9 Float Switches...10 Float Switch Order Form...11 Digi-Level Contents Gauge & Overfill Alarm Analogue Sensor: Submersible Level Transmitter for Fuel Storage...15 Hydrostatic Gauge Equipment...17 Hydrostatic Gauge System Layout...18 Hydrostatic Gauge System Questionnaire...22 Page 2

3 Fill Points, Level Gauges, and Control Equipment FEL Fill Point Equipment is designed to meet your highest expectations. The design and manufacturing process extends the life of FEL s Fill Point Cabinets, meaning that function and aesthetics are maintained for many years. Cabinets are available in a choice of: mild steel, primed and painted, stainless steel with polished or brushed finish Custom made to our Clients specification of dimensions, colour, material, and equipment contents Design can be: surface mounted recessed, standalone, below ground for road traffic or pedestrian load Cabinets can be factory fitted with Fill Valves, Overfill Alarm, Digital Gauge and Controls saving valuable onsite man hours. Page 3

4 Fill Point Cabinets Standard cabinets can be Recessed or Surface mounted to customer requirements, recessed cabinets have a 50mm architrave. A free standing frame is available for Standalone applications. Cabinets are available in various wall thicknesses in both mild steel and stainless steel, both have fully welded construction. Bespoke design service, cabinets available in almost any size, material and colour. Top hung door design with chrome/ stainless bullet hinges, support stay, flush fitting handle with lock. Standard cabinets are supplied with toughened glass vision panel, weather seal and locking strip as well as a mild steel drip tray. Flexible manufacturing allows pipework and electrical service entries as well as equipment support fixings to be formed or added to the cabinet during the manufacturing process. Pre-wiring of incoming electrical supply, overfill alarms, gauging and door operated lighting is also available as an option, saving valuable site installation time. FEL Fill Point Cabinets are designed and manufactured to a high standard. Flexible manufacturing methods allow us to extend the usable life of the cabinets by removing the need for costly on site modifications to create mechanical and electrical service entries into the cabinet. Pipe work and conduit entry holes are formed and equipment support bushes added during manufacture, prior to final painting. Standard Fill Point Cabinets Single Tank Cabinet Twin Tank Cabinet Three Tank Cabinet FEL Product Code Dimensions H x W x D 590 x 665 x x 665 x x 665 x 280 Page 4

5 Single Tank Cabinet Page 5

6 Twin Tank Cabinet Page 6

7 Three Tank Cabinet Page 7

8 Typical Fill Valve Assembly Fill Valve have BSPP inlet and a BSPT outlet Available in sizes 2,2 1/2, 3 and 4 Each fill valve assembly comprises a PN16 rated brass gate valve, brass cap and chain, mild steel support flange welded to a BS1387 outlet connection, complete with fixings. FILL VALVE ASSEMBLIES BSPPXBSPT ½ BSPP x BSPT BSPP x BSPT BSPP x BSPT Page 8

9 Tank Overfill Alarm Designed to provide an audible and visual alarm on high fuel level, with Test and Mute facility. Constructed using IP 65 Rated GRP enclosures with an oil resistant membrane concealing lamps, push buttons and audible alarm. Alarm panels require a 230V ac supply whilst providing a 12V dc control circuit to a dedicated tank mounted float switch configured with a make on rise switch. All Tank Alarm options have integral volt free changeover contacts rated at 5 amps 230V ac which provide remote signalling in the event of alarm. The range covers Single, Twin or Three Tank Alarm Panels, together with a High/Low option and a combined Tank & Bund high level alarm. Full range of Float Switches available. In operation, prior to the commencement of fuel delivery, the Test button should be depressed to ensure that both the audible and visual alarms are in working order prior to the commencement of the fuel delivery. The alarm panels emit an audible alarm on sensing a high fuel level, a red warning lamp will also illuminate. By pressing the Mute button, the audible alarm will be silenced, the red warning lamp will remain illuminated whilst the fuel level remains at high level. Dimensions are: 172mm wide x 130mm high x 76mm deep. Fixing centres are: 4 off 4.2mm diam. holes, 163mm wide x 113mm high. Single Tank Alarm Twin Tank Alarm Three Tank High/Low Alarm Combined Tank & Bund Alarm FEL Product Code Page 9

10 Float Switches Float Switches are available in the following styles: As single switches for High fuel level indication as shown above, working in conjunction with the FEL Valves range of Tank Overfill Alarms whereby an audible and visual alarm is generated by detection of a high fuel level within a tank using a standard make on rise float switch assembly. Also shown above is a Bund float switch with flexible lead, Ref Twin float switches, can provide High and Low switch points for indirect pump start/pump stop applications or to provide pre-set alarm indications, perhaps for overfilling and fuel reorder points. Four float assemblies usually provide a combination of alarm and pump start/pump stop functions, whereby the lower and upper floats give Low Low and High High indication. Customers may choose between Make on Rise or Make on Fall switch orientation together with the switch point dimensions taken from the top of the tank into which the float switches are to be installed. FEL Float switches are manufactured to a robust design, using stainless steel stem, floats and float stops and a brass process connector with 1 BSPP male thread. The terminal housing is of cast aluminium to IP67, whilst the internal switches have a standard rating of 1.0amp 230V ac. The maximum switch depth is 3000mm. Customers should also specify where float switches are to be used on inductive loads, as back EMF protection may be required. FEL float switches can be made suit individual customer requirements for switch rating, orientation, switch depth and materials of construction, please enquire for further information. FEL Valves Product Code / /4 General Description Single switch for High Fuel level Indication usually at 200mm below top of tank. Twin float switch assembly, customer to specify switch point dimensions. Four float switch assembly, customer to specify switch point dimensions. Page 10

11 Float Switch Order Form Page 11

12 Digi-Level Contents Gauge & Overfill Alarm Digital readout of contents, programmable in litres, gallons or US gallons. Programmable for individual rectangular or cylindrical tanks, with accuracy to +/- 0.5% Available for 230V ac or 24V dc power input. Provides 24V dc excitation voltage for 4-20mA signal. The digital controller can provide up to four, 2 amp 230V ac volt free relay set points which can be individually set to energise or de-energise on a rising or falling edge alarm. 4-20mA or 0-10V Retransmission for remote contents reading. MODbus RTU output connectivity option. The digital controller can be used with a wide range of tank mounted sensors which include pressure sensing, capacitance or ultrasonic types. The sensors can be active or non active for current loop ma generation. Please see separate data sheet. Can be used in conjunction with the FEL Valves overfill alarm PCB. This configuration utilises one of the digital controller alarm set points to operate the high fuel level alarm and can do away with the need for a tank mounted float switch, although the overfill alarm may still be used with a float switch if required. The controller can be used to control liquid levels within a tank or vessel by actuating valves or pumps whilst signalling contents level to remote locations for alarm Page 12

13 Standard IP65 ABS enclosure with 20 amp 2 pole isolator can house a digital controller as well as overfill and bund alarms. Dimensions are 188mm wide x 278mm high x 180mm deep. For the combined Controller and overfill alarm, all connections are pre-wired and terminated within the enclosure, leaving only the final field connections to be made. Page 13

14 The FEL Digital Contents Gauge System utilises a 2 wire stainless steel immersion sensor which generates a 420mA signal. The sensor diameter is 30mm allowing a comfortable fit through a 1 tank connection. Standard sensors come with 5m of attached PUR cable, although lengths up to 20m can be specified. Digilevel and overfill alarm enclosures are supplied fitted to our Fill Cabinets, with conduit entries and fixing supports formed during manufacture reducing site installation to a minimum. Programming and pre-commissioning are standard features. Custom Fill Point Cabinet generally to IP54 with toughened glass vision panel, weather seal, internal partition and drip tray. Page 14

15 Analogue Sensor: Submersible Level Transmitter for Fuel Storage The quality and performance of our Series Level Transmitters provides high stability, and reliability in demanding environments. Primary Applications Fuel Level Indication for: Power Generating Industry Building Services Process & Manufacturing Our Level Sensors provide: Wide measuring ranges Corrosion Proof, moist proof, frost proof, seepage prevention Various signal output for industrial standard, flexible calibration High accuracy, excellent stability Page 15

16 Specification Range Accuracy Nonlinearity Stability Output Excitation Working Temperature Compensated temperature Construction Material Electric Connector Protection Class From: Zero to 0.1 bar... Zero to 5.0 bar H 2 O 0.5%FS 0.2%FS 0.2%FS/ Y 4-20mA 2 Wire 0-5V 0-10V 3 Wire 24(12~36)VDC -10~80 0~ Stainless steel housing Vented Cable, Immersion type IP68 Electric Connection Mode Output: 4-20mA Function Colour Excitation+ Red Signal+ Black Output: 0-10V, 0-5V Function Colour Excitation+ Red Signal Blue Common White Page 16

17 Hydrostatic Gauge Equipment Available as Mechanical or Electro/Mechanical systems, Hydrostatic gauge Systems provide a constant read out of tank contents, using internal or external pressure sensors and a range of gauge heads, covering sizes from 100, 160 and 250mm in diameter. Our range of hydrostatic gauges also includes pressure transducers and electronic gauges, as well as current loop amplifiers and direct, hydrostatic switching modules. In operation, the standard hydrostatic gauge is mechanically powered from an internal or externally tank mounted pressure sensor, whereby, the head of liquid within the tank pressurises a metal diaphragm within the sensor. In turn, the sensor diaphragm exerts a pressure which is used by the gauge head to indicate tank contents. This pressure is transferred from the tank mounted sensor/diaphragm assembly to the gauge head via a copper capillary which is sheathed in a terylene reinforced PVC tube. The mechanically driven pressure signal, generated by the tank sensor can also be used to provide a 4 to 20mA analogue signal, via a pressure transducer and forming a current loop. In turn, this proportional signal may then be used to create switching points using a current loop amplifier as well as to provide an analogue readout using an electronic gauge head. The 4-20mA analogue signal makes the FEL gauge system ideal for use in conjunction with a building management system. Gauge head construction is in stainless steel, for both mechanical and electrically driven systems, whilst tank sensors have a ¾ process connection and are usually manufactured from mild steel, with an electron beam welded stainless steel diaphragm. Interconnecting capillary is available to a maximum length of 50m and retransmission of the 4-20mA signal extends the logistical usage to more than 1000m. Page 17

18 Hydrostatic Gauge System Layout Page 18

19 Page 19

20 Page 20

21 Page 21

22 Hydrostatic Gauge System Questionnaire Page 22

23 Did you know that we also supply the following Free Fall Fire Valves Float Switches Motorised Valves Pumps & Panels Fuel Polishers Page 23

SILO PROTECTION SYSTEMS

SILO PROTECTION SYSTEMS SILO PROTECTION SYSTEMS HYCONTROL LIMITED, Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, Tel : 01527 406800 Fax : 01527 406810 Email : sales@hycontrol.com Website : www.hycontrol.com

More information

Software Version 2.01 LEVEL MONITOR MODEL 220

Software Version 2.01 LEVEL MONITOR MODEL 220 Software Version 2.01 LEVEL MONITOR MODEL 220 19 April 2000 CONTENTS 1. Introduction 1 1.1 Model Number Designation 2 1.2 Intrinsic Safety Considerations 3 2. Specification 4 3. Operation 6 3.1 Display

More information

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual ANALOX 5001 ANALOX 5001 Carbon Dioxide Monitor User Manual Analox Sensor Technology Ltd 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT T: +44 (0)1642 711400 F: +44 (0)1642 713900

More information

Low Temperature Zirconia Oxygen Analyzer

Low Temperature Zirconia Oxygen Analyzer Data Sheet SS/ZDT FG Issue 10 Low Temperature Zirconia Oxygen Analyzer ZDT FG Environmental certification MCERTS SIRA certificate MC99000 1/00 User-friendly language options selectable system alarms comprehensive

More information

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

FIREBETA EXTINGUISHING CONTROL PANEL (ECP) F I R E D E T E C T I O N A N D C O N T R O L FIREBETA EXTINGUISHING CONTROL PANEL (ECP) Three versions: 2 areas of detection and 1 area extinguishing 4 areas of detection and 1 area extinguishing 4 areas

More information

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK Analox 1000 Series User Manual Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK T: +44 (0)1642 711400 F: +44 (0)1642 713900 W: www.analox.net E: info@analox.net

More information

INPUT / OUTPUT MINI MODULES

INPUT / OUTPUT MINI MODULES INPUT / OUTPUT MINI MODULES APPLICATION The Addressable Control and Monitor mini modules are the latest technology for a loop powered module. Installed on the same loop with other devices such as detectors

More information

Duct and Rough Service Carbon Monoxide Sensor

Duct and Rough Service Carbon Monoxide Sensor Product Identification and Overview Duct and Rough Service Carbon Monoxide Sensor BAPI s Carbon Monoxide Sensor offers enhanced electrochemical sensing with outstanding accuracy at low concentrations.

More information

Pressurisation units & expansion vessels

Pressurisation units & expansion vessels Pressurisation units & expansion vessels Pressurisation units The new generation of microprocessor controlled pressurisation units Standard Unit/Advanced Unit These microprocessor controlled pressurisation

More information

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module FIRE ALARM CONTROL EQUIPMENT Addendum October 2006 Instructions for new style EN54-4 Power supply unit module MXLK-05 Issue 2.0 June 2007 INSTALLATION Safety Suppliers of articles for use at work are required

More information

DETECTORS, REMOTE CONTROLS & VARIOUS ACCESS.

DETECTORS, REMOTE CONTROLS & VARIOUS ACCESS. Description Code Page DETECTORS, REMOTE CONTROLS & VARIOUS ACCESS. TEMPERATURE & HUMIDTY DETECTORS ROOM TEMPERATURE DETECTORS SAB - SCB 9.2 INDUSTRIAL-TYPE ROOM TEMPERATURE DETECTORS SAA... 9.2 OUTSIDE

More information

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION Environment IMPORTANT INFORMATION It is not anticipated that this equipment will be exposed to adverse environmental conditions without additional protection. Site the equipment in a frost free area. Ensure

More information

Installation Instructions / Operating & Maintenance Manual Ablution Plant Model BTHW-1

Installation Instructions / Operating & Maintenance Manual Ablution Plant Model BTHW-1 Arrow Valves Ltd Operating & Maintenance Manual ABLUTION PLANT Arrow Valves Tel 01442 823 123 Fax 01442 823 234 www.arrowvalves.co.uk Installation Instructions / Operating & Maintenance Manual Ablution

More information

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design TOTAL SOLUTIONS Liquid Level Control Product Guide MATELEC innovative by design Liquid Level Control Contents Dual Pump Controllers Section 1 The Range Common Features Operating Data Control Logic Setup

More information

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM ANNEXUREIII D: FIRE PROTECTION SYSTEM SECTION ADDRESSABLE FIRE DETECTION AND ALARM SYSTEM Supply, Installation, testing and commissioning of Analogue Addressable Fire Alarm Control panel with battery backup

More information

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview Water Leak Detector - Four Zone with open/short-circuit detection Product overview The AX-WLDF is a four zone water leak detection module with open or short circuit sensor cable detection. The module must

More information

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

MSM400 Ultrasonic Suspended Solids Monitoring and Control System Product Data Sheet MSM400 Ultrasonic Suspended Solids Monitoring and Control System Continuous sludge discharge monitor for up to 50% suspended solid The MSM400 system contains a control unit and either

More information

ANALOX 3000 Carbon Monoxide Monitor

ANALOX 3000 Carbon Monoxide Monitor ANALOX 3000 Carbon Monoxide Monitor User Manual Analox Sensor Technology Ltd 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT T: +44 (0)1642 711400 F: +44 (0)1642 713900 W: www.analox.net

More information

MINI BENCH TOP CHAMBER MODEL: MI-80-A-H

MINI BENCH TOP CHAMBER MODEL: MI-80-A-H MINI BENCH TOP CHAMBER MODEL: MI-80-A-H Introduction: The Mini Bench top chambers are compact sized humidity chambers which can be placed on a work bench or on the optional stand provided. These chambers

More information

RQE Series Temperature Controllers

RQE Series Temperature Controllers RQE Series Temperature Controllers For more than 45 years, Thermal Care has manufactured industrial temperature control equipment with the best available component technologies. Our RQE Series mold temperature

More information

Gas ventilation monitoring and control system

Gas ventilation monitoring and control system Gas ventilation monitoring and control system A case study Regulations and customer requirements surrounding the operation and maintenance of gas and ventilation monitoring and control systems in underground

More information

LeakSafe. solutions. WaterSwitch2. Installation Instructions

LeakSafe. solutions. WaterSwitch2. Installation Instructions LeakSafe solutions TM WaterSwitch2 Installation Instructions WATERSWITCH2 COMPONENTS WaterSwitch2 Valve Control Extended Range Valve Driver Valve Water Flow Sensor Leak Detection tape available in 0.3M

More information

ECONOBOOST EB II & EB III Compact Water Booster

ECONOBOOST EB II & EB III Compact Water Booster ECONOBOOST EB II & EB III Compact Water Booster The Stokvis EB II twin pump & EB III triple pump cold water booster units meet today s need for compact, reliable, high performance equipment with modest

More information

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications Data Sheet Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications Ideal for small gas/oil fired boilers Cost effective solution for OEM outlets with a quick return on end-user investment Continuous

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Wed : www.saenchotesei.com WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 920 - Wall, 19 Rack or Panel Mounting Units - 110/230V 50/60Hz AC operation - 250 Addressable

More information

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications Force Pressure Temperature Switch Pressure sensors Ex ia I / IIC T6 acc. to ATEX with internal diaphragm with front flush diaphragm Accuracy: 0,25% and 0,5 % Standard output: 4...20 ma; 2-wire system Description

More information

CATALOGUE. Request to Exit Products Relays, Fuses & Timers TROJAN DEVELOPMENTS Product Catalogue.

CATALOGUE. Request to Exit Products Relays, Fuses & Timers TROJAN DEVELOPMENTS Product Catalogue. CATALOGUE 2018 Product Catalogue Request to Exit Products Relays, Fuses & Timers CONTENTS Table of Contents Introduction: 3 Request & Emergency Egress Devices: Prox Rex 4 Press Rex 5 Em Rex 6 Smart Em

More information

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps Note: The A/E must choose all design values in brackets below before using in project specifications 1 General 1.1 Provide UL listed and FM approved fire pump complete with pump, driver, controller and

More information

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date: Gas Safety Products 4500PPM Installation, operating and maintenance Read these instructions carefully before operating or servicing Rev: 11 Date: 09-07-18 1 * The unit should be installed by a competent

More information

Technical Specification

Technical Specification Technical Specification Surface Area Valve Service Unit Module Semi Flush Area Valve Service Unit Module Product Description The CPX AVSU Module is used in conjunction with area valve service units (AVSU).

More information

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR OM117 OPERATING AND MAINTENANCE MANUAL for the G30 CARBON DIOXIDE MONITOR (Part No: G30) (Intentionally Blank) APPROVAL SHEET DIVEX MANUAL NUMBER: ADVITIUM NUMBER: DOCUMENT TITLE: OM117 GA-OM-5715 G30

More information

Mission Critical. Fuel Supply Systems

Mission Critical. Fuel Supply Systems Fuel Supply Systems Insight Onsite Fuel Supply Systems Page 2 Simplex Mission Critical Fuel Supply Systems are comprehensive, integrated, project-matched fuel management systems for diesel and turbine

More information

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

ZIOU/230 - MAINS IO INSTRUCTION MANUAL Description ZIOU/230 - MAINS IO INSTRUCTION MANUAL The Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third party equipment with the Fire Alarm Control panel

More information

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 2800PPM. Merlin CO2 Monitor 2800ppm. American Gas Safety LLC 1

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 2800PPM. Merlin CO2 Monitor 2800ppm. American Gas Safety LLC 1 Gas Safety Products Merlin CO2 Monitor 2800PPM Installation, operating and maintenance 05/10/2016 American Gas Safety LLC 1 Table of contents 1 General information... 3 2 Installation... 3 2.1 Mounting

More information

Model 4880 Status Output Display Module Manual

Model 4880 Status Output Display Module Manual Model 4880 Status Output Display Module Manual 1-2 150912 Section 1 Introduction The 4880 provides 16 switched outputs, 4 form C relay contacts, and an X10 module interface. See Table 2-1 for electrical

More information

F1202 TRACE HEATING. Road & Ramp

F1202 TRACE HEATING. Road & Ramp Trace Heating Specialists Road & Ramp ROAD & RAMP HEATING ESH Trace Heating Ltd provide a comprehensive range of products to prevent the settlement of snow and formation of ice on roads, ramps and stairs.

More information

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0) Data Sheet 220 LEVEL MONITOR Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com Model 220 Powered by 4-20mA loop Non-linear tank correction Four level alarms Level bar graph display

More information

LeakSafe. solutions. WaterSwitch2. Installation Instructions

LeakSafe. solutions. WaterSwitch2. Installation Instructions LeakSafe solutions TM WaterSwitch2 Installation Instructions QUICK USER GUIDE 1. Turning water ON or OFF using the WaterSwitch Valve Control To turn the water ON, press and hold down the WATER ON button

More information

RTD TEMPERATURE SENSING SYSTEM

RTD TEMPERATURE SENSING SYSTEM General Overview RTD TEMPERATURE SENSING SYSTEM The Prime Technology RTD Temperature System 9219-00-0002 is a three-channel temperature measuring system that utilizes two RTD Temperature Sensor inputs

More information

Gas, oil and heating products. The main line products at competitive prices with even better prices on our VALUE range.

Gas, oil and heating products. The main line products at competitive prices with even better prices on our VALUE range. Gas, oil and heating products The main line products at competitive prices with even better prices on our VALUE range. 84 Gas Fire Fittings Gas Restrictor Elbows Chrome Plated Chrome Mini Ballvalve 500604

More information

water source / fan coils

water source / fan coils MANUAL BALL ALE W/MEMORY STOP (BMS) An adjustable stop position lever to limit travel of the On/Off handle. This allows the ball valve to be closed, and returned to the balance setting position without

More information

AccuBrine automated brine maker Technical Specifications

AccuBrine automated brine maker Technical Specifications Cargill Deicing Technology AccuBrine automated brine maker Technical Specifications All 4 models included Automated Blending System Model (ABM) Automated Blending Remote Truck Fill Model (ABRTF) Automated

More information

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Control Systems Transmitters Sensors Accessories Wall, 19 Rack or Panel Mounting Units 110/230V 50/60Hz AC operation 250 Addressable devices as: Relays, 4-20 Inputs or Gas Detectors

More information

Excel-EN Conventional Fire Control Panel

Excel-EN Conventional Fire Control Panel Available as 2, 4, 6, 8,10 or 12 zones Approved to EN54-2 & 4 Modular expansion zone cards Programmable relays and outputs Optional additional sounder circuits Optional additional programmable outputs

More information

TCS5JBL & TCS5JBLA. Low-Voltage Top-Up Switch

TCS5JBL & TCS5JBLA. Low-Voltage Top-Up Switch 3P Technik TCS5JBL & TCS5JBLA Low-Voltage Top-Up Switch Installation and Operation Manual 3P TCS5JBL/TCS5JBLA Page 1 11/09/16 Table of Contents Description Of Operation...2 Installation...2 Safety Precautions...2

More information

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules Application The Addressable Control and Monitor mini modules are the latest technology for a loop powered module. Installed on the same loop with other devices such as detectors and manual call points,

More information

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 12/23/16 Rev 9 UltraLITE Model ELU General Specification 4.2 KW to 5 KW UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 1.0 General General Specification This specification describes

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

Safegard V4 Bespoke Intelligent Damper Control and Monitoring System

Safegard V4 Bespoke Intelligent Damper Control and Monitoring System August 2016 Range and Features All system wide activity is logged and viewable for diagnostics and preventative maintenance Safegard V4 Bespoke Intelligent Damper Control and Monitoring System Devices

More information

Panther Fan Coil Unit

Panther Fan Coil Unit Panther Fan Coil Unit Energy Efficient EC Motors 280mm Deep Chassis Horizontal Fan Coil Unit INTRODUCTION The Panther, manufactured by Dunham-Bush is an adaptable, easy to use fan coil unit, that performs

More information

FCHM Hydromatic Pump Control Module

FCHM Hydromatic Pump Control Module FCHM Hydromatic Pump Control Module Use To maintain and control water pressure, within a pumped system, for the supply to industrial processes and heating systems. Ensures constant flow and pressure to

More information

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage. LC-100 Tank Level Indicator Engineered specifically for the Offshore & Marine markets, LevelCom TLI s have a proven record of success in 20 years of use in harsh environments. The LC-100 microprocessor

More information

ALARMLINE ANALOGUE Linear Heat Detection System

ALARMLINE ANALOGUE Linear Heat Detection System ALARMLINE ANALOGUE Linear Heat Detection System Alarmline Analogue cable senses temperature variations by continuously monitoring the resistance of specially doped Negative Temperature Coefficient (N.T.C.)

More information

INTRODUCTION / TABLE OF CONTENTS

INTRODUCTION / TABLE OF CONTENTS 1 2 INTRODUCTI / TABLE OF CTENTS Step One The LVCN 51 Series Continuous Relay Controller is a general purpose level controller which provides single tank level indication with dual relays and a repeater

More information

OPERATION AND INSTALLATION MANUAL

OPERATION AND INSTALLATION MANUAL EX+Plus 2 ZONE, 1AREA EXTINGUISHANT CONTROL PANEL OPERATION AND INSTALLATION MANUAL INTRODUCTION The Premier EX Plus is a 2 zone, single area panel for controlling the release of extinguishing gases in

More information

M5200 Industrial Pressure Transducer

M5200 Industrial Pressure Transducer SPECIFICATIONS Wide Temperature Range Compact Variety of Pressure Ports and Electrical Configurations Optional Stainless Steel Snubber CE Compliant and Weatherproof UL Certified Gage, Sealed, Compound

More information

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids Instrumentation for fluids Target Flowmeter Series DP-65 DP-500 Flow measurement of Gases and Liquids Metallic construction. Operates horizontally or vertically DN-80 to DN-500 Flow rate: - Water: 1.5

More information

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side s Frost detector for use on the air side QAF64.2-J QAF64.6-J With active capillary tube sensing element for acquiring the lowest temperature within a range of 0 15 C With startup function Operating voltage

More information

Beck. The differential pressure transmitter for air

Beck. The differential pressure transmitter for air Beck. The differential pressure transmitter for air Differential pressure transmitter 984 General description The differential pressure transmitters of the 984 series are used to measure differential pressure,

More information

CMT MANUAL 6. NMC SENSORS

CMT MANUAL 6. NMC SENSORS CMT MANUAL 6. NMC SENSORS TABLE OF CONTENTS INDEMNITY... 5 DOCUMENT INFORMATION... 5 ACKNOWLEDGEMENTS... 5 6.1 INTRODUCTION... 6 6.2 TEMPERATURE AND HUMIDITY SENSORS... 7 6.2.1. TEMPERATURE SENSOR... 7

More information

HYTEK ATEX APPROVED TANK ALARM

HYTEK ATEX APPROVED TANK ALARM Technical Data HYTEK ATEX APPROVED TANK ALARM Applies to the following models only: - TA3A.P - TA3A.PR - TA3A.B - TA3A.BR Please read carefully before commencing installation Registered Office: HYTEK (GB)

More information

LC2200 Level Controller Installation and Maintenance Instructions

LC2200 Level Controller Installation and Maintenance Instructions 4025250/9 IM-P402-77 AB Issue 9 LC2200 Level Controller Installation and Maintenance Instructions LC2200 ALARM TEST >50% >100%

More information

IST IST /110 IST /220

IST IST /110 IST /220 IST-07-11160 IST-07-11160/110 IST-07-11160/220 Electroimán retenedor de puertas 60kg Electromagnetic Door Holders IST-0711160 are attractively designed and ruggedly constructed. The contact plate can be

More information

MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING

MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING FOR OPERATION FROM 115 AC POWER Andersen Medical Gas 12 Place Lafitte Madisonville, LA 70447 http://www.themedicalgas.com 1-866-288-3783

More information

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER PNEUMERCATOR Liquid Level Control Systems Electronic Systems Excluding LC2000 And TMS Series MAINTENANCE & TROUBLESHOOTING GUIDE 400 300 500 FUEL LEVEL LEAK MONITOR 1 200 600 OIL/GAS NORMAL WATER PNEUMERCATOR

More information

Digital Door Entry System. Specification

Digital Door Entry System. Specification Digital Door Entry System 2 Planit Security Contracts Limited policy is one of continual improvement. The company reserves the right at all times to amend s without prior notification Technical Support

More information

1.1 SECTION INCLUDES.1 Materials and installation for aboveground oil storage tanks..2 Section Waste Management and Disposal.

1.1 SECTION INCLUDES.1 Materials and installation for aboveground oil storage tanks..2 Section Waste Management and Disposal. Page 1 of 8 PART 1 GENERAL 1.1 SECTION INCLUDES.1 Materials and installation for aboveground oil storage tanks. 1.2 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or

More information

Intelligent Security & Fire Ltd

Intelligent Security & Fire Ltd full installation, commissioning and operating manuals can be downloaded from www.haes-systems.co.uk combined addressable / conventional fire alarm control panel User Guide Approved Document No. MFBU-04

More information

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps. Issued 2006/08/01 Section 13920 Packaged Fire Pumps and Controllers Page 1 of 7 PART 1 GENERAL 1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1

More information

Active Infrared Multi Beam Sensors. R Series

Active Infrared Multi Beam Sensors. R Series Active Infrared Multi Beam Sensors R Series TECHNICAL MANUAL INDEX GENERAL SAFETY RECOMMENDATIONS 3 CONFORMITY 4 WARRANTY 4 INTRODUCTION 5 FEATURES 5 OPERATIONAL RANGE 6 SETUP TRANSMITTER (TX) 6 SETUP

More information

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 8720 IR Detection of carbon dioxide Dräger Polytron 8720 IR Detection of carbon dioxide The Dräger Polytron 8720 IR is an advanced explosion proof transmitter for the detection of carbon dioxide in percent volume or ppm It uses a high performance

More information

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED FUEL OIL DAY TANKS SST Series - Engineering Submittal SST Series - Advanced Line Day Tanks Construction: UL 142 aboveground steel tank all seam welded, square, atmospheric tank of heavy gauge steel with

More information

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting. AMC-RAM-4 Refrigerant Alarm Module USER MANUAL IMPORTANT: Please read the installation and operating instructions completely and carefully before starting. Filename: 3310405B, DOC, AMC_RAM4_Manual.doc

More information

High Efficiency Compressed Air Dryers. Adsorption Dryers Classical System INTELLIGENT AIR TECHNOLOGY

High Efficiency Compressed Air Dryers. Adsorption Dryers Classical System INTELLIGENT AIR TECHNOLOGY High Efficiency Compressed Air Dryers Adsorption Dryers Classical System INTELLIGENT AIR TECHNOLOGY Heatless Regenerative Adsorption Dryers A18TX A930TX and A18TXA A157TXA Compressed air purification equipment

More information

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 5700 IR Detection of flammable gases and vapours Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive

More information

your dust explosion protection experts

your dust explosion protection experts your dust explosion protection experts HMI Overview Camera Systems Pag. 2 Remote I/O Barriers & Isolators Pag. 3 Purge Pag. 3 Plugs & Receptacles Lighting Pag. 5 Control Stations Pag. 6 Terminal Boxes

More information

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems 5/25/16 rev 6 elite Model ELN General Specification 550 W to 1.5 KW elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems 1.0 General General Specification This specification

More information

industrial electronics electronic level measurement system

industrial electronics electronic level measurement system industrial electronics electronic level measurement system Table of content About company Continuous level meters ULM 70 ULM 53 HLM 25, HLM 16 CLM 36 Limit level sensors DLS 27 FLD 48 "Meduse" CLS 18 CLS

More information

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Polytron 8310 IR Detection of flammable gases and vapour Dräger Polytron 8310 IR Detection of flammable gases and vapour The Dräger Polytron 8310 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

Flopurge TS. Operation Manual

Flopurge TS. Operation Manual Flopurge TS Operation Manual Part Number 079-0204 Spectron Gas Control Systems United Kingdom Unit 4, Herald Court, University of Warwick Science Park, Coventry, CV4 7EZ +44 (0)24 7641 6234 sales@spectron-gcs.com

More information

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOCELL 300-V. Vertical DHW cylinder. 130to500litrecapacity. Vitotec folder, register 17

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOCELL 300-V. Vertical DHW cylinder. 130to500litrecapacity. Vitotec folder, register 17 VIESMANN VITOCELL 300-V Vertical DHW cylinder 130to500litrecapacity Datasheet Part numbers and prices: see pricelist File in: Vitotec folder, register 17 VITOCELL 300-V Type EVA and EVI Vertical DHW cylinder

More information

Level gauges Series LS Level indicator, switch and transmitter for liquids

Level gauges Series LS Level indicator, switch and transmitter for liquids Level gauges Series LS Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Measuring range: from 150 mm

More information

UV Flame Supervision System

UV Flame Supervision System 7 783 UV Flame Supervision System DETACTOGYR LFE50 Series 02 ISO 9001 The LFE50 is a self-checking UV flame supervision system designed for use with continuously operating burners or for burners running

More information

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW Stainless steel range of condensing boilers Outputs from 50kW to 660kW Designed to meet carbon reduction targets Lifetime service and support Totally dependable. page 1 www.pottertoncommercial.co.uk Contents

More information

Bristol Babcock Oil Content Monitor "oil in water"

Bristol Babcock Oil Content Monitor oil in water NORTHEAST CONTROLS INC. ONLINE www.nciweb.net 123 Pleasant Avenue - Upper Saddle River - New Jersey 07458 USA Tel: 201-327-7660 / Fax: 201-327-3242 Bristol Babcock Oil Content Monitor "oil in water" General

More information

Functional Door Entry System. Specification

Functional Door Entry System. Specification Functional Door Entry System 1 Planit Security Contracts Limited policy is one of continual improvement. The company reserves the right at all times to amend s without prior notification Technical Support

More information

The Remote alarm Panel, TYPE RAPv2

The Remote alarm Panel, TYPE RAPv2 1. Introduction The Remote alarm Panel, TYPE RAPv2 The microprocessor based remote monitor from Metron Eledyne is the latest version of a whole line of successful products, marketed previously under the

More information

Flostop TS D7E and A8E. Operation Manual

Flostop TS D7E and A8E. Operation Manual Flostop TS D7E and A8E Operation Manual United Kingdom Spectron Gas Control Systems Ltd, Unit 4, ATU1, University of Warwick science Park, Coventry, +44 (0) 24 7641 6234 sales@spectron-gcs.com Germany

More information

MINIMUM REQUIREMENTS FOR ADOPTABLE WASTEWATER PUMP STATIONS

MINIMUM REQUIREMENTS FOR ADOPTABLE WASTEWATER PUMP STATIONS MINIMUM REQUIREMENTS FOR ADOPTABLE WASTEWATER PUMP STATIONS Date: Site Name: Address: Note that this document is not a technical specification and is not a complete checklist for all the specified requirements.

More information

AquiTron. AT-WM Water Monitor DATA SHEET

AquiTron. AT-WM Water Monitor DATA SHEET AquiTron AT-WM Water Monitor DATA SHEET AT-WM Water Monitor The Aquitron AT-WM is a leak monitoring system that has been specifically designed to comply with the requirements of BREEAM (BRE Environmental

More information

High Pressure Conductivity Monitor

High Pressure Conductivity Monitor Product Data Sheet PDS 71-EDS880/1/rev.A August 2006 Model EDS880/1 High Pressure Conductivity Monitor COMPLETE SYSTEM FOR THE DETERMINATION OF CONDUCTIVITY IN HIGH PRESSURE SYSTEMS SENSOR INSTALLS DIRECTLY

More information

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670 Bulletin AV-670 Series 670 Hood Monitor Specifications - Installation and Operating Instructions DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Phone: 219/879-8000 Fax: 219/872-9057

More information

TQ4400 TANKSCAN GAS SAMPLING SYSTEM OPERATING MANUAL

TQ4400 TANKSCAN GAS SAMPLING SYSTEM OPERATING MANUAL TQ4400 TANKSCAN GAS SAMPLING SYSTEM OPERATING MANUAL TQ Environmental Plc July 2009 This manual must not be copied or reproduced in part without the express written permission of TQ Environmental PLC.

More information

ELECTRIC COMBINATION BOILER. (European Patent No: Design Right Protected.) TH12-450U MRK 2

ELECTRIC COMBINATION BOILER. (European Patent No: Design Right Protected.) TH12-450U MRK 2 ELECTRIC COMBINATION BOILER (European Patent : 1757678. Design Right Protected.) TH12-450U MRK 2 INCLUDES THERMAL SOLAR & WOOD BURNING STOVE WITH WATER JACKET APPENDIX This product is suitable for connection

More information

LC1350 Level Controller

LC1350 Level Controller LC1350 Controller Description The Spirax Sarco LC1350 has two alarm channels that can be independently configured high or low to control the water level of a boiler, tank or vessel by operating a pump,

More information

Centro-Matic Automated Lubrication Systems System Controls

Centro-Matic Automated Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

BOILER HOUSE PRODUCTS GMS

BOILER HOUSE PRODUCTS GMS GMS BOILER HOUSE PRODUCTS Contents Page 2 Introduction 3 Condensate Pumpsets 6 Blowdown Vessels 8 Boiler Feed Tanks Page 10 Chemical Dosing Pots 11 Vent Heads 11 De-Aerator Heads Introduction to Boiler

More information