IST IST /110 IST /220
|
|
- Curtis Benson
- 5 years ago
- Views:
Transcription
1 IST IST /110 IST /220 Electroimán retenedor de puertas 60kg Electromagnetic Door Holders IST are attractively designed and ruggedly constructed. The contact plate can be adjusted to suit any door angle. Electromagnetic Door Holders have a minimum holding force of approximately 35/50kg and can hold most type of doors. In application, the device releases the door when signaled by the fire alarm system, which then allows the door closing mechanism to close the door. This unit also have a Manual Release Switch to release the door manually or to test the operation of the unit. Each unit has a built-in electronic circuit that is designed for better reliability and performance. Incorporation of manual release switch Residual magnetism release electronic circuit for instant release Wide angle rotateable contact plate High holding force Supply voltage Supply current Input power Holding force Net/Gross weight 24V DC 110VAC 220VAC 60 ma 1.5 W 35/60 Kg minimum 652/690 g SUITABLE FOR INDOOR APPLICATION
2 Rotulas de longitudes especiales para retenedores de puertas Standard Ref. IST IST-09-R033 Longitud: 280mm IST-09-R028 Longitud: 230mm IST-09-R025 Longitud: 200mm IST-09-R020 Longitud: 150mm
3 IST IST-09-R100 IST
4 IST /24/6 IST /110/8 IST /220/4 Campanas de Alarma de 4 /6 /8 Alarm bells are professionally designed to meet the needs of fire fighting and detection system with central control equipment. The simplicity of the design incorporates fewer working parts, easy installation and high level of efficiency, thus making the bells capable for operating under most adverse conditions. Alarm bells are designed to meet the requirements of BS5839 Part 1. Model IST Well proven high reliability Plug-in power supply Interchangeable base Wide operating voltage range Zero standby current Low current consumption Loud and clear ringing tone Universal application-available in three DC voltages 6V, 12V and 24V. AC voltages available in 110V and 220V for use with most alarm systems. DECIBEL LEVELS Is highly suitable for surface or semi-concealed fixing, which, in this case, means that the base of bell can be sunk into the wall using a junction box so that the edges of the bell are only 12mm from the wall surface. AC TYPE DECIBEL RATING AT 1M (3FT) Voltage Amps 100mm (4") 150mm (6") 200mm (8") dB 95dB 97dB dB 105dB 106dB DC TYPE DECIBEL RATING AT 1M (3FT) Voltage Amps 100mm (4") 150mm (6") 200mm (8") dB 103dB 105dB Net/Gross Weight 626/668g 888/966g 1296/1445g SIRIM TEST REPORT 83LL129 (MODEL ) MOUNTING INSTRUCTIONS The bell must be mounted with its striker pointing downwards.
5 IST /1 IST /2 IST /1 Pulsador con llave de Test (1x NC,NO,C) IST /2 Pulsador con llave de Test (2x NC,NO,C) Manual Call Point is suitable for open or close circuit system and is professionally designed for use in fire detection systems with central control equipment. Alternative terminals are provided for open or close circuits. When wired for open circuit operation, the circuit closes instantly when the glass is smashed. Openings are provided for 3/4" O conduit entries from top, bottom and the back. The casings are moulded from specially selected engineering plastic, which comes in 5 different colours, with high impact strength, high resistance to heat. All metal parts are made of brass and phosphor bronze to ensure life long resistance against corrosion. A high realibility micro switch is also included. Double terminal wire connectors for independent input and output connections which facilitate installations when used in looping. Provision of thread protection plugs which protect the thread of the brass inserts on the base box when conceal fixing is necessary. Incorporation of the instant test operation which is activated by a special key provided. Size Current ratings 88mm X 88mm X 55mm 12/24V DC 10A 48V DC 3A (Optional) 250V AC 10A (Optional) Net/Gross weight 160/184g Connections TERMINAL Max 2.5mm² cable AUSTRALIAN STANDARD CERTIFICATE NO. 345 OPTIONAL FEATURES Is designed to meet the requirement of BS5839 Part 2 and approved by Australian Standard AS 1603 Part 5. RANGE OF CASING COLOURS White, Yellow, Green, Red, Blue Polycarbonate transparent protection cover Super bright light emitting didode (LED) Monitoring resistor Blocking diode Switch Choices - two single pole double throw (SPDT) micro switch. six terminal provided
6 IST IST Pulsador con llave de Test ( NC+NO) Manual Call Point IST is suitable for open or close circuit system and is professionally designed for use in fire detection systems with central control equipment. Alternative terminals are provided for open or close circuits. When wired for open circuit operation, the circuit closes instantly when the glass is broken. Cable knockout seals are provided for 3/4" D conduit entries from top, bottom and the back. The casings are moulded from specially selected engineering plastic, which comes in 5 different colours, with high impact strength, high resistance to heat. All metal parts are made of brass and phosphor bronze to ensure life long resistance against corrosion. Double terminal wire connectors for independent input and output connections which facilitate installations when used in looping. Instant test operation is available through activation utilizing a special key provided. Suitable for surface or flush mounting. Size (mm) Current ratings Net/Gross weight Connections 88 x 88 x 55 12/24V DC 10A 150/176g Terminal Max 2.5mm² cable RANGE OF CASING COLOURS OPTIONAL FEATURES Polycarbonate transparent protection cover Different range of casing colours white, yellow, green, red, blue Specific languages available on facial layout upon request. Blue, Green, Red, Yellow, White
7 IST Sirenas Is a versatile, compact electronic sounder that is designed ideally for fire, security and hazard warning. This solid-state sounder offers significantly high output levels at low current consumption. The casing is designed using a high grade ABS engineering plastic that has excellent resistance to impact and heat. Featuring a red polythene removable conduit plug for easy conduit entries, is designed to work effectively with most detection systems incorporating central control equipment. It also facilitates conceal fixing with the provision of thread protection plugs that prevent damage to the brass insert thread at the base of the box.perfectly combining performance and functionality, has a protection classification of IP 54 and is designed to meet the requirements of BS5839 Part 1:1980. Functional-Inherent design offers wide operating voltage range Efficiency-Low power consumption with high output Accessible-Removable conduit plug offers easy conduit entries Versatile-Suitable for surface or flush mounting Practical Design-Provision of thread protection plugs protect brass inserts when conceal fixing is necessary Compatible-Works perfectly well with most detection systems Dimensions current voltage frequency Sound output level temperature Approximate weight Protection classification Terminal capacity 88mm x 88mm x 43mm (75mm with base) Maximum 35mA at 24V DC 24V DC 600Hz - 2.5KHz 00± 3dB at 24V DC at 1m -10 C min to +60 C max 144 g IP 54 2 x 1.5mm² conductors
CONTENTS NBM-06 Bell (6") Page 1
CONTENTS NBM-06 Bell (6") - - - Page 1 NBM-08 Bell (8") - - - Page 1 LFB-24 Sounder Banshee - Page 2 VCT--NT Base Version Sounder Page 2 VCT--NT Wall Version Sounder Page 2 VRS1-R or W Bedhead Sounder
More informationELECTRONIC SOUNDER STROBE Model : AVD-C407
ELECTRONIC SOUNDER STROBE Model : AVD-C407 MULTRON range of combination Electronic Sounders with Strobe Lights are designed to complement our Fire Alarm products both technically and aesthetically as an
More informationSignaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.
Signaling Devices Acoustic Signaling Devices 28 Optical Signaling Devices 30 26 Signaling Devices Acoustic Signaling Devices Acoustic Signaling Devices MSS300-SA SG 200 DS 10 LSN/GLT GLT GLT GLT Operating
More informationINPUT / OUTPUT MINI MODULES
INPUT / OUTPUT MINI MODULES APPLICATION The Addressable Control and Monitor mini modules are the latest technology for a loop powered module. Installed on the same loop with other devices such as detectors
More informationFlexSQUARE Square shaped beacons
FlexSQUARE Square shaped beacons Size comparison Mini/Midi/Maxi Optical LED Permanent Light 5 LED Flashing Light 6 LED EVS 8 Your benefits The compact LED beacon is particularly versatile. With an IP67
More informationYodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon
Sounders Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon Pg 185 186 187 188 189 190 191 Y03 1YA030207 1YA030203 1YA030205 YL030/24 A1:2002 YL030110/230 UL464 C22.2 No. M1983 BS
More informationIntellia Sounder Bases and Sounder Beacon Bases
Intellia Bases and Beacon Bases The Base and Beacon Base are a local-area alarm devices designed for indoor use. They can be connected only to detection systems using Intellia detectors and FX control
More informationLEAKSTOPPER RANGE Multizone water leak detection systems
LEAKSTOPPER RANGE Multizone water leak detection systems WHAT DOES THE PRODUCT DO? The LeakStopper detects water leaks and instantly triggers an alarm to warn you. It is capable of monitoring between 2
More informationPrem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES
Prem1er EVACS16 VOICE ALARM CONTROL PANEL 4 16 ZONES Installation Manual Approved Document No: GLT.MAN-141 PAGE 1 INDEX INDEX... 2 Summary... 3 Safety information & use of this manual... 5 Installation
More informationSounder AX03, AX05. Loud signalling device with 32 different signals. Application. Design. Signalling devices with good directivity
FUNKE+HUSTER FERNSIG Sounder AX03, AX05 Loud signalling device with 32 different signals 3 AC and DC versions 3 High volume up to 112 db(a) 3 Low current consumption 3 Choice of 32 different signal tones
More informationFill Point, Level Gauges, and Control Range
Fill Point, Level Gauges, and Control Range Page 1 Contents Fill Points, Level Gauges, and Control Equipment... 3 Fill Point Cabinets... 4 Single Tank Cabinet... 5 Twin Tank Cabinet... 6 Three Tank Cabinet...
More informationSeries 65 Product Guide MAN 3036
Series 65 Product Guide MAN 3036 TABLE OF CONTENTS Page No. 1 Ionisation Smoke Detector... 1 1.1 Operating Principles:... 1 1.2 Product Codes... 2 1.3 Integrating Version:... 2 1.4 Options:... 2 1.5 Safety
More informationConventional Smoke Detectors KFAPO
Kingfisher Company, inc. Conventional Smoke Detectors KFAPO Features: Wide operating voltage, 9-33 VDC Advanced electronic technology Flashing LED Magnetic test switch Proven detection performance Designed
More informationThe complete conventional fire warning system
The complete conventional fire warning system www.espuk.com MAG2P 2 Zone Fire Panel 2 programmable zones Active end of line monitoring and head removal 30 fire detectors per zone Unlimited number of call
More informationINSTRUCTION MANUAL (ATEX)
INSTRUCTION MANUAL (ATEX) ISmA1M Minialarm Intrinsically Safe Round ISmA1M Volume Control Tone Generator S3 Tone Selection Switches Fig 1 Simplified block diagram The ISmA1M sounder is CE marked for compliance
More informationCATALOGUE. Request to Exit Products Relays, Fuses & Timers TROJAN DEVELOPMENTS Product Catalogue.
CATALOGUE 2018 Product Catalogue Request to Exit Products Relays, Fuses & Timers CONTENTS Table of Contents Introduction: 3 Request & Emergency Egress Devices: Prox Rex 4 Press Rex 5 Em Rex 6 Smart Em
More informationFDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules
Application The Addressable Control and Monitor mini modules are the latest technology for a loop powered module. Installed on the same loop with other devices such as detectors and manual call points,
More informationIndustries. As a premier global manufacturing company, we believe that great brands are
JSB Fire Systems ONE COOPER Every day, thousands of people all over the world use products made by Cooper Industries. As a premier global manufacturing company, we believe that great brands are built on
More information56W Vapor Proof LED Fixture V Dimmable - DALI Network lms - IP67 - Outdoor Applications
56W Vapor Proof LED Fixture - 0-10V Dimmable - DALI Network - 7000 lms - IP67 - Outdoor Applications Part #: GVP-ADC-48-2L-LED-D-V2 Page: 1 The Larson Electronics GVP-ADC-48-2L-LED-D-V2 Dimmable LED Light
More informationFTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS
QUICK USER GUIDE FOR, 2 & 4 ZONE PANELS INDICATORS COLOUR INDICATION MON FAULT Yellow On when a fault condition has occurred, or if no other fault Led is on, this indicates 24v auxiliary fuse failure.
More informationINSTRUCTION & SERVICE MANUAL
INSTRUCTION & SERVICE MANUAL D1xC COMBINED RADIAL HORNS & STROBES For Use In Hazardous Locations - Gas 3) Ratings and Markings The D1xC1 and D1xC2 combined alarm horns and strobes comply with the following
More informationD720 and D1255 Command Centers
Command Centers and Keypads D720 and D1255 Command Centers 33704G The D720 and D1255 Command Centers are low profile, surface mount units that can annunciate events from the 9000 Series Control/Communicators
More informationGate Mount Pool Alarms
Home Products About GRI Contact GRI Where to Buy Testimonials What's New! Gate Mount Pool Alarms GT10-2/GT10-4 Microprocessor Controlled Monitors Entry to Pool and Spa Areas Weather Resistant for Outdoor
More informationIQ8Control C Fire Alarm Panel
IQ8Control C Fire Alarm Panel State-of-the-art processor technology Maximum cable length for esserbus: 3,500 m Graphics supported, high performance programming tool Innovative alarm signalling by means
More information4) Intrinsic Safety Certification
INSTRUCTION MANUAL Minialert Intrinsically Safe Round Combined Unit Section Volume Control Tone Generator S2 S3 Tone Selection Switches Fig 1 Simplified block diagram The combined unit is CE marked for
More informationHardwired Alarm Accessories
Hardwired Alarm Accessories Contents Wireless Door Contact for WGAP864 WGAP864WDCV2...3 Wireless PIR Sensor (Pet Immunity) For WGAP864 WGAP864WPIRV2...4 Dual Technology PIR / Microwave Detector ALH-PIRMW...5
More informationRDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:
RDM LOCK G-1 1400 Series Electromagnetic Lock The patented 1400 Series Electromagnetic Lock is universal for all types of applications, including outdoor use. The innovative design will reduce installation
More informationOPERATION AND INSTALLATION MANUAL
EX+Plus 2 ZONE, 1AREA EXTINGUISHANT CONTROL PANEL OPERATION AND INSTALLATION MANUAL INTRODUCTION The Premier EX Plus is a 2 zone, single area panel for controlling the release of extinguishing gases in
More informationConsumer Products Catalog
Consumer Products Catalog C O N T R O L S Home Monitoring & Lighting This affordable line from Reliance Controls permits you to monitor your home or cabin for power outages, flooding, temperature drop
More informationVibratone Horns. Models 350 and 450
FEDERAL SIGNAL CORPORATION Vibratone Horns Models 350 and 450 DESIGNED FOR ROUTINE SIGNALING Range of up to 200 feet Coded or sustained tones Model 350 12, 24, 120 and 240VAC; Model 450 12, 24, 125 and
More informationVIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm
VIMPEX Sounder Range Fire Alarms Banshee Electronic Sounders FlashDome EN 54-3 Evacuation Audible Alarm BS 5839-1 Beacons The range of sounders, beacons, sounder beacons and accessories represents the
More informationEmergi-Lite Orbis detectors
Emergi-Lite Orbis detectors Emergi-Lite Orbis brings the latest in fire detector microprocessor technology to the Firetec and Eurofire systems. Non-addressable (conventional) smoke and heat sensors respond
More informationFIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL
FIRE ALARM CONTROL PANEL COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL CONTENTS 1. INTRODUCTION. 3 1.1 HANDLING THE PCBS 1.2 USING THIS MANUAL
More informationFIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4
FIRE ALARM CONTROL PANEL INSTALLATION MANUAL Approved Document No. GLT -201-7-3 Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4 CONTENTS 1. INTRODUCTION... 1.1 HANDLING THE PCBS... 1.2 USING THIS MANUAL... 1.3
More informationE2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.
E2S Datasheet 1.2.1 v10a ISmA1 ISminialarm The ISmA1 is a compact, 100dB(A) alarm sounder. Approvals include ATEX, IECEx and GOSTR for Zone 0 applications and FM approval for Class I Division 1 and Class
More informationFIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module
FIRE ALARM CONTROL EQUIPMENT Addendum October 2006 Instructions for new style EN54-4 Power supply unit module MXLK-05 Issue 2.0 June 2007 INSTALLATION Safety Suppliers of articles for use at work are required
More informationHazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs
Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs Part #: HALP-ANC-48-2L-LED-D-V2 Page: 1 Made in the USA The Larson Electronics HALP-ANC-48-2L-LED-D-V2
More informationConventional Fire Detection
SECTI 4: page 1 Section 4: Conventional Fire Detection Contents System Architecture Control Panel Automatic & Manual Detection Manual Call Points Smoke Detectors Heat Detectors Beam Smoke Detectors Duct
More informationFOR TM-16 EMERGENCY WARNING SYSTEM
INSTALLATION AND INSTRUCTION MANUAL FOR TM-16 EMERGENCY WARNING SYSTEM SPECIAL NOTE BOONE CABLE WORKS & ELECTRONICS, INC. 1773-219 TH LANE P.O. BOX 429 READ THIS ENTIRE BOOKLET BOONE, IOWA 50036 USA BEFORE
More informationInterface and EOL Modules 8
Interface and EOL Modules Interface Modules Series 420 25 Interface Modules Series 100 291 EOL Modules 293 254 Interface and EOL Modules Interface Modules Series 420 Interface Modules Serie 420 Interface
More informationFireLock High Pressure Butterfly Valve. System No. Submitted By Spec Sect Para Location Date Approved Date
MEA: 276-99-E CSFM: 7770-0531:113 The Series 766 high pressure butterfly valve features a weatherproof actuator housing approved for indoor or outdoor use. It has been developed for fire pump metering
More informationExcel-EN Conventional Fire Control Panel
Available as 2, 4, 6, 8,10 or 12 zones Approved to EN54-2 & 4 Modular expansion zone cards Programmable relays and outputs Optional additional sounder circuits Optional additional programmable outputs
More informationTCS5JBL & TCS5JBLA. Low-Voltage Top-Up Switch
3P Technik TCS5JBL & TCS5JBLA Low-Voltage Top-Up Switch Installation and Operation Manual 3P TCS5JBL/TCS5JBLA Page 1 11/09/16 Table of Contents Description Of Operation...2 Installation...2 Safety Precautions...2
More informationIntelligent Security & Fire Ltd
full installation, commissioning and operating manuals can be downloaded from www.haes-systems.co.uk combined addressable / conventional fire alarm control panel User Guide Approved Document No. MFBU-04
More informationHalf-Dome. the Design-Tower. Compact
the Design-Tower 81 Compact 82 compact signal towers Visual-audible LED signal tower system in semicircular design Modern signal tower design Available to order pre-configured or with customised tower
More informationAddressable and Conventional Fire Protection
Addressable and Conventional Fire Protection Simply reliable F I R E P R O T E C T I O N The MAGPro and Fireline systems has been created to balance performance, reliability and aesthetics whilst being
More informationProcess Alarm Module RTA 421
Technical Information TI 074R/24/ae Process Alarm Module RTA 421 Alarm module and power supply for monitoring current or voltage signals Application Areas Plant and machine construction Panel builders
More information4 wire conventional alarm system
Scimitar 4 wire conventional alarm system from Channel Safety Systems Scimitar 4 wire conventional alarm system The Scimitar Fire Alarm Control System is a comprehensive range of high specification conventional
More informationCelebrating YEARS Manufacturers of Visual & Audible Signalling Devices. NEW Exd
Celebrating 15 YEARS Manufacturers of Visual & Audible Signalling Devices 1998-2013 NEW Exd INTRODUCTION MOFLASH to the world of Based in Birmingham at the heart of Great Marine FM 558977 P P P P P P P
More informationINSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas
INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas UL 1203 CSA C22.2 NO. 30-M1986 The D1xS1 and D1xS2 Alarm Horns also comply with the following standards for signaling
More informationThe system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.
FireCell Radio Hub Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication Loop powered Diagnostics port Range in excess of 150 metres Overview The model FCX-500-001
More informationBulb Overview DESCRIPTION PART NO. TOTAL VOLTAGE FOR USE WITH: LENGTH(mm) Free-standing Beacons Accessories. Optical Signal Devices
Bulb Overview PART NO. DESCRIPTION TOTAL LENGTH(mm) VOLTAGE FOR USE WITH: 955 840 34 Bulb BA15d 5 W 42 12 V 200 203 209 641 800 840 845 955 840 35 Bulb BA15d 5 W 42 24 V 200 203 209 641 800 840 845 955
More informationCHECK NEW PRODUCTS SECTION FOR NEW INNOVATIVE SOLUTIONS
CHECK NEW PRODUCTS SECTION FOR NEW INNOVATIVE SOLUTIONS Table of Contents - Electronic Access & Releasing Devices Pushbutton Access Release Devices................ H1-H8 620/631 Series Heavy Duty Pushbuttons
More information56W Hazardous Location LED Fixture - C1D2 - Stainless Steel - Dimmable - DALI Network
56W Hazardous Location LED Fixture - C1D2 - Stainless Steel - Dimmable - DALI Network Part #: HALSS-ADC-48-2L-LED-D-V2 Page: 1 Made in the USA The HALSS-ADC-48-2L-LED-D-V2 Hazardous Location LED Fixture
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT
More informationDICTATOR Hold-Open Systems for Hazardous Areas
DICTATOR for Hazardous Areas Products to be used in hazardous areas obviously have to meet special demands. The European ATEX directives (first the EN 94/9/EG and then the directive 2014/34/ EU) brought
More informationSnifter ATEX22 VERSION. User Manual. Distributor
Snifter ATEX22 VERSION User Manual Distributor Version 1.4 09/09/2009 Table of Contents 1. INTRODUCTION... 3 1.1. Safety... 3 1.2. Product overview... 4 1.3. How does it work?... 4 2. INSTALLATION... 5
More informationBulletin 855T 70 mm Control Tower Stack Lights
Bulletin 855T 70 mm Control Tower Stack Lights Light Modules Red Flashing Incandescent (Black Housing) 855T B 10 FN 4 a b c d a b c d Housing Color Voltage Light Module Type Lens Color Code Description
More informationEFBW series - BiWire Ultra control panel
4.2 Control panels and repeater panels EFBW series - BiWire Ultra control panel Eaton s new BiWire Ultra fire detection system is unlike any other standard conventional system as the panel, conventional
More informationXenex Conventional Fire Detection & Alarm System
SECTI 4: page 1 Section 4: Xenex Conventional Fire Detection & Alarm System SECTI 4: page 3 Xenex system architecture Beam Transmitter Beam Receiver End of Line Call Point Smoke Detector Smoke Detector
More informationCM800 Emergency Call System
Submittal Package as of 5/25/2017 Phone: 828.524.9967 Toll-Free: 800.327.8466 Sales: Option 2 Tech Support: Option 3 324 Industrial Park Road Franklin, NC 28734 tektone@tektone.net Fax: 828.524.9968 Copyright
More informationTek-ENTRY Apartment Entry Systems
Tek-ENTRY Apartment Entry Systems Submittal Package as of 5/25/2017 Phone: 828.524.9967 Toll-Free: 800.327.8466 Sales: Option 2 Tech Support: Option 3 324 Industrial Park Road Franklin, NC 28734 tektone@tektone.net
More informationTX6831 Data Sheet. Features. Benefits
Audio/Visual Alarm Combined audible and visual alarm signalling, for use with sensors and monitoring systems Environments: Mining Tunnelling Machine monitoring Features TX6831 For use with sensors and
More informationPage. 1-2 Sepra-Lite Integral Optic Level Switches. 3-5 Electro Optic Level Systems: Probe and Controller
Order from: C A Briggs Company 622 Mary Street; Suite 101; Warminster, PA 18974 Phone: 267-673-8117-800-352-6265; Fax: 267-673-8118 Sales@cabriggs.com - www.cabriggs.com Page 1-2 Sepra-Lite Integral Optic
More informationLEAKSTOPPER 1 Single zone water leak detection system
LEAKSTOPPER 1 Single zone water leak detection system WHAT DOES THE PRODUCT DO? The LeakStopper 1 detects the presence of water in environments where it is not supposed to be. Should water be detected
More informationTopscan G3 Presence detector for automatic doors
Topscan G3 Presence detector for automatic doors Your added value! Smallest presence detector of its class User-friendly, solid and simple operation Easy and significantly faster installation Mechanically
More information2G & 3G GSM Door Contact Alarm
2G & 3G GSM Door Contact Alarm www.gsm-activate.co.uk MODEL RF - PIR PAGE 1 Product Information Our 2G/3G GSM Door Contact Alarm is a standalone alarm system for smaller rooms inside properties. It will
More informationTaps, Shower & Flush Valve Range
CI/SfB (74) X Taps, Shower & Flush Valve Range First Edition DOLPHIN Washrooms worth experiencing You can tell how much a company cares about its customers by inspecting its washrooms Copyright Bell-Chem
More informationstandards: standards:
INSTRUCTION MANUAL D2xB1LD2 LED Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING HAZARD
More informationE2S Datasheet v10a
E2S Datasheet 1.2.3 v10a ISmC1 ISminialert The ISmC1 is a compact combined 100dB(A) alarm sounder and L.E.D. beacon only one Zener barrier or galvanic isolator required to run both sounder & beacon or
More informationSOUNDER BASES AND SOUNDER BEACON BASES
Tech Data Sheet D01513GB3 44/2011 Fire Detection SOUNDR BASS AND SOUNDR BACON BASS Intellia Sounder Bases and Sounder Beacon Bases The Sounder Base and Sounder Beacon Base are a local-area alarm devices
More informationPrecept Marine Control Panel Application Guide
Precept Marine Control Panel Application Guide Contents Page 1.0 Cabinet Specifications 2 2.0 Panel Hardware Specifications 5 3.0 Panel Configuration 8 4.0 Technical Specifications 8 5.0 Battery Sizes
More informationFIREBETA EXTINGUISHING CONTROL PANEL (ECP)
F I R E D E T E C T I O N A N D C O N T R O L FIREBETA EXTINGUISHING CONTROL PANEL (ECP) Three versions: 2 areas of detection and 1 area extinguishing 4 areas of detection and 1 area extinguishing 4 areas
More informationInstallation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels
Installation and user manual for the FX range of fire panels 1, 2, 4 and 8 zone panels Contents Panel installation 3 Panel connections 3 Wiring connection drawings 4 Panel facilities 6 Installation check
More informationVibratone Horns. Models 350 and 450
FEDERAL SIGNAL CORPORATION Vibratone Horns Models 350 and 450 DESIGNED FOR ROUTINE SIGNALING Range of up to 200 feet Coded or sustained tones Model 350 12, 24, 120 and 240VAC; Model 450 12, 24, 125 and
More informationOverview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.
Wireless Overview www.incitefire.com.au Overview Fundamentals FIREwave is a wireless based family of products which is fully integrated into Hochiki s renowned ESP intelligent hardwired system. This seamless
More informationPRODUCT INFORMATION. Sounder SG 200. BDL F.01U A3.en / ST FIR/ PRM1 / zab. Page 1 of 10
PRODUCT INFORMATION PI 38.43 Sounder SG 200 Page 1 of 10 Table of Contents 1. Product Description............................... 3 2. Features......................................... 3 3. Functional Description............................
More informationSeries M22 Signaling Beacons and Alarms
Series M22 Beacons and Alarms Signaling S I G N A L G E R Ä T E Signaling Solutions Loud and Clear M22 Panel Mount Signaling Beacons and Alarms from the Auer company are the perfect compliment to Sprecher
More informationProduct Manual Standard Asserta Sounder Range
Product Manual Standard Asserta Sounder Range Document Structure: Steve Martin - 18/09/08 Technical Information: Chris Anderson - 14/10/08 Cooper Fulleon Ltd Llantarnam Park Cwmbran South Wales NP44 3AW
More informationUltrasonic Proximity Sensor
Ultrasonic Proximity Sensor Compact, Column-shaped Sensor Capable of Sensing Range Setting Ensures the stable detection of a variety of objects regardless of the color, transparency, or material (metallic
More informationReliably Advanced Extinguishing Control
Reliably Advanced Extinguishing Control 14 years. 60 countries. Still Advanced. We re the same people, with the same commitment to excellence and customer satisfaction and now we have a brand that reflects
More informationINSTRUCTION & SERVICE MANUAL
INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following
More informationThe ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features
990-052, Issue 6 20 March 2006 ID50 Series Single Loop Intelligent Fire Alarm Panels Section: Intelligent Fire Alarm Panels GENERAL The NOTIFIER ID50 series single loop intelligent fire alarm panels, has
More informationSigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009
Sigma K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels Operation and Maintenance Manual Man-1048 Issue 05 October 2009 CONTENTS Contents... Page Safety & Installation...2 Installation - continued...3
More informationAudible warning devices for external alarm
VdS SCHADENVERHÜTUNG VdS Publisher: Gesamtverband der Deutschen Versicherungswirtschaft e.v. (GDV) Büro Schadenverhütung Publishing house: VdS Schadenverhütung Rules for Intruder Alarm Systems Audible
More informationSOLID PLUS HEAT
SOLID PLUS HEAT WWW.ROTAID.COM PRODUCT SHEET The Rotaid Solid Plus Heat is a highly robust and durable AED wall cabinet that ensures a recognizable, solid and sustainable storage of your AED device in
More informationSTANDARD FEATURES SPECIFICATIONS
MAG LOCK P/N 300768 STANDARD FEATURES Holding Force: 1500 lbs.(675 Kg.) Easy Installation: Versatile mounting bracket for new and existing doors and frames. Sensor: Built-in Hall effect crystal affected
More informationGuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces
Highly Visible Alignment Lasers for Visually Demanding Surfaces The Guideline 2 Range The provides a reliable and robust industrial alignment laser for a wide range applications including the alignment
More informationCat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE
Cat. N STOP & GO automatic resetting 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat. N (s) : 4 062 88 / 4 062 89 CONTENTS PAGE 1. Description - Use... 1 2. Product
More informationDESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS
DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS SEEKIRK, INC. 2420 Scioto Harper Dr. Columbus, OH 43204 Tel: (614) 278-9200 FAX: (614) 278-9257
More informationIntroduction to Flow Switch
Introduction to TM Solutions Flow Detection, Switching & Control Flow switches detect a change in state from flow or no-flow within pipe or ducting. Correspondingly, the sensor inverts a contact to signal
More informationMotion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels
MS3602CH 2 Channel Motion Sensor For Outdoor Use Wall & Ceiling Mounted Quick & Easy Installation 2 Channels Channel 2 Distance Wiring Diagram 220-240V ~ 50Hz 14A Max. (cosø=1) 3000W for incandescent load
More informationLEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL
LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL The LeakStopper Multizone detects the presence of water in environments where it is not supposed to be. Should water
More informationSo hot, so quick! Venus Water Heaters presents the Quik series, a range of tankless water heaters with the latest heat exchanger technology.
So hot, so quick! Venus Water Heaters presents the Quik series, a range of tankless water heaters with the latest heat exchanger technology. Venus Quik Tankless water heaters are fitted with a unique advanced
More informationMS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels
R 12 Clintonville Road, Northford, CT 06472 Phone: (203) 484-7161 FAX: (203) 484-7118 Instruction Manual for the MS-4012/4024 and CMS-4012/4024 Fire Alarm Control Panels Document 15586 5/11/93 Revision:
More informationBristol Babcock Oil Content Monitor "oil in water"
NORTHEAST CONTROLS INC. ONLINE www.nciweb.net 123 Pleasant Avenue - Upper Saddle River - New Jersey 07458 USA Tel: 201-327-7660 / Fax: 201-327-3242 Bristol Babcock Oil Content Monitor "oil in water" General
More informationHouses, farms, caravans, boats, buses and RV s, campervans, camper trailers, 4WD s and trucks, cabins, cars and tiny houses, hinterland retreats,
LPG AC DC Houses, farms, caravans, boats, buses and RV s, campervans, camper trailers, 4WD s and trucks, cabins, cars and tiny houses, hinterland retreats, houseboats, fishing shacks and camp sites. If
More informationRules for Intruder Alarm Systems
Rules for Intruder Alarm Systems Opening detectors (Magnetic contacts) Part 1: Requirements VdS 2120en 03/96 (03) Subject 44 1 General; 2 Terms and definitions; 3 Classification 1 General 1.1 Scope These
More informationSlimline, Energy Saving & Smart. It's the game changer!
Innovators of the award-winning Vortex EcoSmart, the world s first hand dryer to achieve a Guinness World Records title, and winner of the Energy & Environmental Product Service award, SAVORTEX now introduces
More informationFire Signalling. Signalling Solutions
Fire Signalling Signalling Solutions Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market place.
More information