Duo-Aire. VAC-1 Vertical Air Curtain Wall Hood Single Plenum
|
|
- Percival Stevens
- 5 years ago
- Views:
Transcription
1 VC-1 Vertical ir Curtain Wall Hood Single Plenum Model VC-1 single plenum vertical air curtain wall ventilator. Constructed of stainless steel where visible and aluminized steel where concealed. The make up air curtain shall be of the low velocity high volume design and shall include adjustable airfoil louvers for directional control of the air curtain. ir curtain shall not exceed 325 feet per minute discharge velocity. The supply air plenum shall contain integral perforated plates to equalize supply air flow along the total length of the supply air slot. Ventilator shall be complete with exhaust collar and supply air collar with UL fire damper. ll external seams shall be fluid welded and ground/polished to match ventilator finish. Ventilator to be listed to meet NSF and UL 710 Standards and constructed to meet NFP-96 requirements. Grease trough to be easily removable and sloped to removable grease cup. STNDRD FETURES Vertical ir Curtain Supply ir Discharge 300 Series Stainless Steel Construction UL Listed luminum Grease Filters UL Listed Pre-Wired Incandescent Lights Surface Mounted Control Panel Removable Grease Trough and Cup UL Listed Supply Fire Damper Concentric or Parallel Duct Collars Installed OPTIONS UL Listed Stainless Steel Grease Filters UL Listed Fluorescent Lights UL Listed Insulated Top, ack and/or Ends for Zero Clearance to Combustible 14 Deep Fire Protection Cabinet 400 Stainless Steel Where Exposed 18 Gauge luminized Steel, Painted Exterior Full-Integrated Duct and Rooftop Package Supply ir Foil Directional Louvers 10" HNGING RCKETS (See reverse side for larger drawing) Note: DoubleCollars Required over 14 3" 50",56" 62",6 VC-1 Vertical ir Curtain Wall Hood Single Plenum UILT IN CCORDNCE WITH NFP 96 UL # MH HOODS WITHOUT EXHUST DMPERS UL # MH HOODS WITH EXHUST DMPERS Revised July 2001 Duo-ire
2 VC-1 Series Specifications 3" Project: ORDER ENTRY INFORMTION 10" Item: 50",56" 62",6 Representative: HNGING RCKETS Model: Length: Width: Height: Qty: 23 1/ -30" UL LISTED GLOE LIGHT(S) VERTICL IR CURTIN WITH OPTIONL DIRECTIONL LOUVERS Duct - Exhaust CFM: Supply CFM: Entered by: Concentric Parallel FLUSH MOUNTED CONTROL PNEL Date: 16" OR 20" TLL UL LISTED GRESE FILTERS Drawings Req d: Y N Section View REMOVLE GRESE TROUGH ND CUP Note: DoubleCollars Required over 14 List Miscellaneous Options Separately Duo-ire reserves the right to make changes in design and specifications without prior notice.
3 VC-2 Vertical ir Curtain Single Island Hood Model VC-2 single plenum vertical air curtain Single Island ventilator. Constructed as one module. Constructed of stainless steel where visible and aluminized steel where concealed. The make up air curtains shall be of the low velocity high volume design and shall include adjustable airfoil louvers for directional control of the air curtain. The supply air curtains shall be the full length of the ventilator, both sides. ir curtain shall not exceed 325 feet per minute discharge velocity. The supply air plenums shall contain integral perforated plates to equalize supply air flow along the total length of the supply air slot. Ventilator shall be complete with exhaust collar and supply air collars with UL fire dampers. ll external seams shall be fluid welded and ground/polished to match ventilator finish. Ventilator to be listed to meet NSF and UL 710 Standards and constructed to meet NFP-96 requirements. Grease trough to be easily removable and sloped to removable grease cup. STNDRD FETURES Vertical ir Curtain Supply Discharge 300 Series Stainless Steel Construction UL Listed luminum Grease Filters - V Filter ank UL Listed Pre-Wired Incandescent Lights Surface Mounted Control Panel Removable Grease Trough and Cup UL Listed Supply Fire Damper Concentric or Parallel Duct Collars Installed OPTIONS UL Listed Stainless Steel Grease Filters UL Listed Fluorescent Lights UL Listed Insulated Top and/or Ends for Zero Clearance to Combustible 14 Deep Fire Protection Cabinet 400 Stainless Steel Where Exposed 18 Gauge luminized Steel, Painted Exterior Full-Integrated Duct and Rooftop Package Supply ir Foil Directional Louvers HNGING RCKETS (See reverse side for larger drawing) 6'-8' VC-2 Vertical ir Curtain Single Island Hood UILT IN CCORDNCE WITH NFP 96 UL # MH HOODS WITHOUT EXHUST DMPERS UL # MH HOODS WITH EXHUST DMPERS Revised July 2001 Duo-ire
4 VC-2 Series Specifications Project: Item: ORDER ENTRY INFORMTION Representative: 6'-8' Model: Length: Qty: Width: Height: HNGING RCKETS Note: DoubleCollars Required over 14 Duct - Exhaust CFM: Supply CFM: Concentric Parallel Entered by: UL LISTED GLOE LIGHT(S) 23 1/ -30" VERTICL IR CURTIN WITH OPTIONL DIRECTIONL LOUVERS FLUSH MOUNTED CONTROL PNEL Date: Drawings Req d: Y N 12" OR 16" TLL UL LISTED GRESE FILTERS REMOVLE GRESE TROUGH ND CUP List Miscellaneous Options Separately Section View Duo-ire reserves the right to make changes in design and specifications without prior notice.
5 VC-3 Vertical ir Curtain Double Island Hood Model VC-3 single plenum vertical air curtain Double Island ventilator. Constructed in two modules, to be mated back to back at time of installation. Constructed of stainless steel where visible and aluminized steel where concealed. The make up air curtains shall be of the low velocity high volume design and shall include adjustable airfoil louvers for directional control of the air curtain. The supply air curtains shall be the full length of the ventilator, both sides. ir curtain shall not exceed 325 feet per minute discharge velocity. The supply air plenums shall contain integral perforated plates to equalize supply air flow along the total length of the supply air slot. Ventilator shall be complete with exhaust collar and supply air collars with UL fire dampers. ll external seams shall be fluid welded and ground/polished to match ventilator finish. Ventilator to be listed to meet NSF and UL 710 Standards and constructed to meet NFP-96 requirements. Grease trough to be easily removable and sloped to removable grease cup. STNDRD FETURES Vertical ir Curtain Supply Discharge 300 Series Stainless Steel Construction UL Listed luminum Grease Filters UL Listed Pre-Wired Incandescent Lights Surface Mounted Control Panel Removable Grease Trough and Cup UL Listed Supply Fire Damper Concentric or Parallel Duct Collars Installed OPTIONS UL Listed Stainless Steel Grease Filters UL Listed Fluorescent Lights 14 Deep Fire Protection Cabinet 400 Stainless Steel Where Exposed 18 Gauge luminized Steel, Painted Exterior Full-Integrated Duct and Rooftop Package Supply ir Foil Directional Louvers UL Listed Insulated Top and/or Ends for Zero Clearance to Combustible HNGING RCKETS (See reverse side for larger drawing) 8'-12' VC-3 Vertical ir CurtainDouble Island Hood UILT IN CCORDNCE WITH NFP 96 UL # MH HOODS WITHOUT EXHUST DMPERS UL # MH HOODS WITH EXHUST DMPERS Revised July 2001 Duo-ire
6 VC-3 Series Specifications Project: Item: ORDER ENTRY INFORMTION Representative: Model: 8'-12' Length: Qty: HNGING RCKETS Note: DoubleCollars Required over 14 Width: Height: Duct - Exhaust CFM: Supply CFM: Entered by: Concentric Parallel UL LISTED GLOE LIGHT(S) Date: 23 1/ -30" VERTICL IR CURTIN WITH OPTIONL DIRECTIONL LOUVERS Drawings Req d: Y N FLUSH MOUNTED CONTROL PNEL 16" OR 20" TLL UL LISTED GRESE FILTERS List Miscellaneous Options Separately REMOVLE GRESE TROUGH ND CUP Section View Duo-ire reserves the right to make changes in design and specifications without prior notice.
7 ENGINEERING WORKSHEET MODEL C / VC-1 MODEL NUMER EXHUST CFM 600 CFM EXHUST COLLR COLLR VC x 10 VC x 11 VC x 12 VC x 14 VC x 16 VC VC x 20 VC x 22 VC x 30 VC x x 30 VC x x 30 VC ) 12 x 15 VC ) 12 x 16 NOTE: Minimum overhang of 6 at hood front and ends. CFM may vary based on actual cooking equipment design.
8 ENGINEERING WORKSHEET MODEL C / VC-2 MODEL NUMER EXHUST CFM 600 CFM EXHUST COLLR COLLR VC x 14 VC x 16 VC x 17 VC x 19 VC x 20 VC x 22 VC x 25 VC x 27 VC x 28 VC x 28 VC x 29 VC ) 19 x 19 4) VC ) 20 x 20 4) NOTE: Minimum overhang of 6 at hood front and ends. CFM may vary based on actual cooking equipment design.
9 ENGINEERING WORKSHEET MODEL C / VC-3 MODEL NUMER EXHUST CFM 600 CFM EXHUST COLLR COLLR VC x 14 VC x 16 VC x 17 VC x 19 VC x 20 VC x 22 VC x 25 VC x 27 VC x 28 VC x 28 VC x 29 VC ) 19 x 19 4) VC ) 20 x 20 4) NOTE: Minimum overhang of 6 at hood front and ends. CFM may vary based on actual cooking equipment design.
Low Wall Back Shelf Exhaust Canopy
ITEM NO. 710 Powerline Road Suite H Deerfield Beach, FL 33442 (954) 570-9860 (800) 322-8730 FAX (954) 570-9865 Low Wall Back Shelf Exhaust Canopy Model LW APPLICATION Wall mounted canopy style ventilator
More informationSECTION COMMERCIAL-KITCHEN HOODS
SECTION 23 38 13 COMMERCIAL-KITCHEN HOODS SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. 2. Delete other items or paragraphs in the section that are not applicable and renumber
More informationREQUIREMENTS FOR HOOD PLANS
DEPARTMENT OF PUBLIC HEALTH Division of Environmental Health REQUIREMENTS FOR HOOD PLANS Submit one (1) set of plans drawn to scale of at least ¼-inch per foot. Plans shall conform to applicable California
More informationBasic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives
Design Considerations for Commercial Kitchen Ventilation By John A. Clark, P.E., Member ASHRAE Commercial kitchen ventilation (CKV) design must consider everything needed to be coordinated to form a system
More informationMODELS D49M30SB, D49M36SB, D49M48SB DOWNDRAFT
REVI SEDVERI SI ON-Noti npr i nt edcat al og SPECIFICTION SHEET D49M30S, D49M36S, D49M48S DOWNDRFT Powerful VERTEX TM Complete Capture Design rivals the finest island hoods. Compact design allows the choice
More informationLABEL PLEASE NOTE: ALL APPLICATIONS AND SITE PLANS MUST BE COMPLETED IN BLACK OR BLUE INK ONLY
STAFF USE ONLY Thurston County Resource Stewardship 2000 Lakeridge Dr. S.W. Olympia, WA 98502 (360)786-5490 / (360)754-2939 (Fax) TDD Line (360) 754-2933 Email: permit@co.thurston.wa.us www.co.thurston.wa.us/permitting
More informationAIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems
233100 AIR DISTRIBUTION PART 1: GENERAL 1.01 RELATED SECTIONS A. Section 230700 HVAC Insulation B. Section 237300 Air Handling C. Section 230900 Building Automation and Control System Guidelines D. Section
More informationEXHAUST FAN SCHEDULE
DUCTWORK SCHEDULE CONCEALED SUPPLY AIR RECTANGULAR, RTU CONCEALED SUPPLY AIR RECTANGULAR, ERV CONCEALED SUPPLY AIR ROUND, RTU CONCEALED SUPPLY AIR ROUND, ERV EXPOSED SUPPLY AIR ROUND RUNOUTS RETURN AIR
More informationNotable Changes in the Mechanical Codes
Notable Changes in the Mechanical Codes July 2004 The following are some of the changes between the 1997 Uniform Mechanical Code and the 2003 International Mechanical Code(M) and the 2003 International
More informationMODEL: JRSVH SERIES JEAN S RESTAURANT SUPPLY 426 SOUTH STAPLES CORPUS CHRISTI, TEXAS PH: (361)
C US FILE#:MH48178 MODEL: JRSVH SERIES JEAN S RESTAURANT SUPPLY 426 SOUTH STAPLES CORPUS CHRISTI, TEXAS 78401 PH: (361)884-9800 WWW.JEANSRESTAURANTSUPPLY.COM UL Standard for Safety for Exhaust Hoods for
More informationMSYS 4490 AC Systems
MSYS 4490 AC Systems Winter 2015 KITCHEN VENTILATION SYSTEMS By Satwinder Singh 12/02/2015 1 12/02/2015 2 By Satwinder Singh 1 12/02/2015 3 12/02/2015 4 By Satwinder Singh 2 Type I: Types of Hoods used
More informationInspection Checklist Mechanical Rough in
Property Owner Name: Property Address: Permit Number: Inspectors Name: Review Date: Permits and Plans 1. Job address is posted in a visible location. (R319.1) 2. Permit and approved plans are on site and
More informationVOSE ELEMENTARY SCHOOL
IRULTION IRULTION TOILET OFFIE FLEX ONFERENE MF IT SPEILIST MULTI-USE KITHEN KEY PLN FS1.1 Food Service Equipment Plan IRULTION IRULTION TOILET OFFIE FLEX ONFERENE MF IT SPEILIST MULTI-USE KITHEN KEY PLN
More informationLombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS
Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS (630) 620-5750 Fax: (630) 629-2374 www.villageoflombard.org COMMERCIAL HOOD & DUCT SYSTEM PLAN REVIEW REQUIREMENTS International
More informationSECTION AIR HANDLING UNIT
SECTION 15800 - AIR HANDLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR
More informationAir Replacement Systems
GLOL FINISHING SOLUTIONS ir Replacement Systems > Eliminate problems with drafts, stale or contaminated air, and temperature stratification > reate balanced building pressure and maintain proper comfort
More informationIMPORTANT SAFETY INSTRUCTIONS
INSTLLTION INSTRUCTIONS HOOD MODELS WSX, WCX, & WEX 35 Thor Place rea, Ca 98 (877) 387-67 IMPORTNT SFETY INSTRUCTIONS PLESE RED ENTIRE INSTRUCTION EFORE PROCEEDING. INSTLLTIONS MUST COMPLY WITH LL LOCL
More informationAir Replacement Systems
G L O L F I N I S H I N G S O L U T I O N S ir Replacement Systems > Eliminate problems with drafts, stale or contaminated air, and temperature stratification > reate balanced building pressure and maintain
More informationA. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.
SECTION 15622 DIRECT GAS-FIRED BURNER & MANIFOLD SYSTEM PART 1: GENERAL 1.1 Section includes: A. Direct gas-fired heater modules B. Controls C. Equipment schedule 1.2 Related Sections A. Section 01655:
More information1 Exam Prep Florida Building Code-Mechanical Tabs and Highlights
1 Exam Prep Florida Building Code-Mechanical Tabs and s These 1 Exam Prep Tabs are based on Florida Building Code-Mechanical, 2014. Each 1 Exam Prep tabs sheet has five rows of tabs. Start with the first
More informationB. Design meeting requirements of the particular class and type of cabinet as follows:
SECTION 11535 BIOLOGICAL SAFETY CABINETS PART 1 - GENERAL 1.1 RELATED SECTIONS A. Section 15212 (22 60 13) Laboratory Gas Connections B. Section 15810 (23 33 00) Ductwork Connections C. Section 16150 (26
More informationManufacturer of HVAC Equipment Since ,000 sq. ft. on 16 acres. Colton, California USA
Manufacturer of HVAC Equipment Since 1916 400,000 sq. ft. on 16 acres Colton, California USA Visual factory Vertically integrated manufacturing BELT-DRIVEN AIR HANDLERS 800 12,000 CFM Horizontal Vertical
More informationChromalox Electric Airduct Heaters with Fintube Heating Elements. Conduit Entrance Plate. DHRF Remote Controls Flanged Type Figure 4
Chromalox DIVISION SALES REFERENCE DATE 4 (Supersedes PF455-2) FEBRUARY, 2001 SECTION Chromalox Electric Airduct eaters with Fintube eating Elements D PF455-3 161-562766-001 Conduit Entrance Plate DII
More informationMake-Up Air Systems. Performance. Model DGK, DG, DGX
DGK, DG, DGX 96 Make-Up ir Systems Direct Fired Gas Heat DGK-15-25 DG-10-20 -30 DGX-12-22 -32 *DGX with PDX-12-22 -32 est vailable Program 5 Days 10 Days 15 Days * est vailable based on size and capacity
More informationELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. U.S.A. WARNING FOR YOUR
More informationKitchen Ventilation Hood Permit Application
TOWN OF BRIGHTON Office of the Fire Marshal 2300 Elmwood Avenue Rochester, New York 14618 (585) 784-5220 Office (585) 784-5207 Fax Kitchen Ventilation Hood Permit Application Plan Submittals and Installation
More informationA. Standards: Except where modified or exceeded by the requirements of this Specification, conform to the following standards:
SECTION 11 53 53 BIOLOGICAL SAFETY CABINETS PART 1 - GENERAL 1.1 QUALITY ASSURANCE A. Standards: Except where modified or exceeded by the requirements of this Specification, conform to the following standards:
More informationB. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.
PART 1: GENERAL 1.01 General Requirements A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the
More informationD. Fabrication: Steel or Aluminum with baked enamel off-white finish. B. Type: Square and rectangular, adjustable pattern, multi-louvered diffuser.
SECTION 23 37 00 - AIR OUTLETS AND INLETS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Diffusers. 2. Registers 3. Grilles. PART 2 - PRODUCTS 2.1 ROUND CEILING DIFFUSERS B. Product Description:
More informationResidential Fans & Air Purifiers
Residential Fans & ir Purifiers ESSORIES Fan ccessories Mounting lamps for Rigid Duct M mounting clamps are designed for use with rigid duct. The foam neoprene layer creates an air tight and solid installation
More informationMERIT SERIES Up Flow / Horizontal
G S F U R N C E S G40UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D T Bulletin No. 210278 December 2008 Supersedes May 2007 FUE 80% Input 44,000 to 154,000 Btuh Nominal dd on Cooling 1.5
More informationINSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods
INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods Ultra Series Models: UL2824 UL2830 UL2836 CONTENTS: Part 1 - Planning The Installation Part 2 - Electrical Connection Part 3
More informationINTELLINOX DEMAND CONTROL KITCHEN VENTILATION
INTELLINOX DEMAND CONTROL KITCHEN VENTILATION COMMERCIAL KITCHEN VENTILATION EXPERTS FOR OVER 25 YEARS WHO WE ARE WE REALLY UNDERSTAND YOUR KITCHEN Extensive knowledge with all kitchen hood manufacturers
More informationGREEN REFRIGERANT R-410A
PH-SERIES PCKGED HET PUMPS Cooling Capacities: 2, to 6, Heating Capacities:, to 2, SEER:. HSPF: GREEN REFRIGERNT R-4 FRONT (INDOOR IRFLOW) END OF UNIT CK (OUTDOOR IRFLOW) END OF UNIT Standard Engineered
More informationCooktop Chimney Ventilation Hoods
INSTALLATION GUIDE Cooktop Chimney Ventilation Hoods Contents Wolf Cooktop Chimney Ventilation Hoods.......... 3 Cooktop Chimney Hood Specifications............ 4 Cooktop Chimney Hood Installation.............
More informationFT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER
Item # Quantity C.S.I. Section 11400 FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER STANDARD FEATURES Opti-RinSe system with dual rinse Water usage 72 gph @ 20 psi Microprocessor controls Low temperature
More informationInstallation Instructions
Installation Instructions 30" ELECTRIC Downdraft Cooktop Modules selected at time of purchase IMPORTANT: Read and save these instructions. Part No. 208040 A 438589 Quick Reference Table of Contents: Pages
More informationA. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:
SECTION 15860 - FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR MECHANICAL
More informationInspection Checklist Mechanical Final
Property Owner Name: Property Address: Property Parcel Number: Inspectors Name: Review Date: Permits and Plans 1. Job address is posted in a visible location. (R319.1) 2. Permit and approved plans, and
More informationDear Concessionaire,
Dear Concessionaire, In order to provide a comprehensive review & inspection of the Vendor application please review the following as guidance to a complete application and preparedness for inspection.
More informationELECTRIC DRYER INSTALLATION INSTRUCTIONS
ELECTRIC DRYER INSTLLTION INSTRUCTIONS Para una version de estas instrucciones en español, visite www.whirlpool.com Table of Contents DRYER SFETY... 2 Installation Requirements... 3 Tools and Parts...
More informationSUBMITTAL SCHEDULE & DATA
SUBMITTAL SCHEDULE & DATA Gas- and Oil-Fired Unit Heaters, Infrared Heaters, and Indoor Duct Furnaces Job Name: Date: 10/31/2016 Location: Engineer: Submitted by: Jeff Musto Architect: Contractor: Model
More informationFT900BD FLIGHT-TYPE DISHWASHER
Item # Quantity C.S.I. Section 11400 FT900BD FLIGHT-TYPE DISHWASHER STANDARD FEATURES Opti-RinSe system Water usage 120 gph @ 20 psi Microprocessor controls Low temperature alert Blower dryer with 2 H.P.
More informationSECTION AIR OUTLETS AND INLETS
SECTION 23 37 00 AIR OUTLETS AND INLETS PART 1 - GENERAL 1.1 SUMMARY A. Section includes diffusers, light troffer diffusers, registers/grilles, door grilles, louvers, louvered penthouses, roof hoods, goosenecks.
More informationCommercial Packaged Rooftop Systems
Competitively priced rooftop systems for one to three story buildings Commercial Packaged Rooftop Systems Engineered for flexibility and performance McQuay Commercial Rooftop Systems System performance
More informationBulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications
Bulletin C6200 MAY 20 3 Buffalo Air Handling Big Buffalo Custom Applications Buffalo Air Handling Big Buffalo The historic strength of Buffalo Air Handling is the custom designed air handling equipment
More information5.0 Installation Instructions
5.0 Installation Instructions 5.1 Location Within the laboratory, pharmacy, etc., the ideal location of the biological safety cabinet is away from personnel traffic lanes, air vents (in or out), doors
More informationML 1 93 UH 070 x P 36 B
PRODUCT SPECIFICTIONS GS FURNCES ML93UH MERIT SERIES Upflow / Horizontal Bulletin No. 20588 October 202 Supersedes ugust 202 FUE - 93% Input - 44,000 to 32,000 Btuh Nominal dd-on Cooling - 2 to 5 Tons
More informationBrown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS
SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett
More informationGOLDEN TEMPLE AMRITSAR SPECIFICATIONS FOR KITCHEN EQUIPMENT
GOLDEN TEMPLE AMRITSAR SPECIFICATIONS FOR MODULAR KITCHEN EQUIPMENT Dated: 12/08/2014 ARCHITECT HABITAT ARCHITECTS 1777, MAHARAJ NAGAR, LDH. CLIENT SHIROMANI GURDWARA PARBANDHAK COMMITTEE. INDIA - 1st
More informationBUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS
BUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used by
More informationCombustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.
Combustion ir System Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641. DVL Double-wall interior close clearance stovepipe for connecting woodstoves to
More informationDivision 11 - Equipment
Division 11 - Equipment 11 40 00 Food Service Equipment 1. Prepare specifications for food service equipment in close coordination with University food service personnel. 2. Specify that the Contractor
More informationCHAPTER 5: EXHAUST SYSTEMS
MOTORS, FANS AND FILTERS 503.1 General. Motors and fans shall be sized to provide the required air movement. Motors in areas that contain flammable vapors or dusts shall be of a type approved for such
More informationAIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)
AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory
More informationSECTION DUCTWORK
PART 1 GENERAL 1.1 REFERENCES SECTION 23 31 00 DUCTWORK A. ASHRAE - Handbook, Duct Design B. ASHRAE - Handbook, Duct Construction C. ASTM A90/A90M - Standard Test Method for Weight (Mass) of Coating on
More informationSECTION HVAC DUCTS AND CASINGS
PRT 1 GENERL 1.01 SECTION INCLUDES. Metal ductwork. C. Casing and plenums. D. Duct cleaning. 1.02 RELTED REQUIREMENTS SECTION 23 3100 HVC DUCTS ND CSINGS. Section 01 6116- Volatile Organic Compound (VOC)
More informationProject Name: Project Address: Installer Name: Installer Address: Date of Inspection:
FIRE DEPARTMENT Kitchen Range Hood Fire Suppression System Acceptance Test Project Name: Project Address: Installer Name: Installer Address: Date of Inspection: DOCUMENTATION NO Plans have been reviewed
More informationRevolving Oven Gas Wood Model 140
JOB MODEL 140 GAS WOOD ITEM # High temperature pizza oven. Cooking range is from 650f to 900f. CLEARANCES: Install the oven with a minimum 2 clearance on sides and back from any combustible material. Noncombustible
More informationInstallation Instructions
Instructions for Dryers Original Instructions Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.) www.speedqueen.com Part No. 5439R October
More information101 S. George St 116 E Gas Ave York, PA York, PA (717) (717)
City of York Qdot Engineering 101 S. George St 116 E Gas Ave York, PA 17405 York, PA 17405 (717) 849-2329 (717) 744-8315 INSPECTION CHECKLIST Residential Mechanical 2009 Codes This checklist is intended
More informationA. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.
Section 15 _ Energy Recovery Air Handling System Part 1: GENERAL 1.1 Section Includes: A. Energy Recovery Air Handler B. Controls (most by Others) C. Equipment Schedule 1.2 Related Sections: A. Section
More information2015 ICC Commercial Cooking Systems
2015 ICC Commercial Cooking Systems Based on the: 2015 International Building Code (IBC ) 2015 International Mechanical Code (IMC ) 2015 International Fire Code (IFC ) 2015 International Fuel Gas Code
More informationSERIES: FC & IL FORNO CLASSICO BUILT BY CRAFTSMEN. TESTED BY TIME.
DESIGN & INSTALLATION GUIDE SERIES: FC & IL FORNO CLASSICO BUILT BY CRAFTSMEN. TESTED BY TIME. FC-516, FC-616 AND FC-816 IL FORNO CLASSICO OVENS BAKERS PRIDE OVEN COMPANY, LLC. 1307 N. Watters Rd., Suite
More informationInstallation Instructions
Instructions for Dryers Original Instructions Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.) www.speedqueen.com Part No. D5439R2
More informationHeavy Duty Transformer. Low Voltage Circuit Breaker. Visit us at For the latest technical information,
ENGINEERING DT Duralok Plus luminized Steel Heat Exchanger Pressure es Factory installed Field Wiring Make Up Box can be installed on either side Tool Less Entry Sight Glass Terminals for ccessory Connections
More informationTYPICAL CPA SPECIFICATIONS
TYPICAL CPA SPECIFICATIONS 4/10/2017 UNIT CONSTRUCTION: Casing: The exterior casing of the unit shall be constructed of 18-gauge, G235 galvanized steel (optional stainless steel or aluminum), unpainted.
More informationML180UH. MERIT SERIES Upflow / Horizontal. AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons ML 1 80 UH 070 X P 36 B
E N G I N E E R I N G D T G S F U R N C E S ML80UH MERIT SERIES Upflow / Horizontal Bulletin No. 20590 June 20 Supersedes May 20 FUE - 80% Input - 44,000 to 32,000 Btuh Nominal dd-on Cooling - 2 to 5 Tons
More informationFood Service Establishment Plan Review Form
CITY OF PARK RIDGE 505 BUTLER PLACE PARK RIDGE, IL 60068 TEL: 847/ 318-5291 FAX: 847/ 318-6411 TDD:847/ 318-5252 URL:http://www.parkridge.us Food Service Establishment Plan Review Form THE FOLLOWING INFORMATION
More informationUtility and Centrifugal
Utility and entrifugal Utility and entrifugal reenheck s tiered centrifugal product offering reenheck s tiered model approach gives you flexibility in size, performance and construction, matching the appropriate
More informationInstallation Instructions
Installation Instructions for Dryers Inside... Dimensions... Before You Start... 4 Installing the Dryer... 5 Installer Checklist... Back Cover Date Purchased Model Number Serial Number Keep these instructions
More informationUNDERFLOOR AIR DISTRIBUTION PRODUCTS
TLE OF CONTENTS UNDERFLOOR IR DISTRIUTION PRODUCTS GENERL PRODUCT OVERVIEW FLOOR "SWIRL" DIFFUSERS VV LINER FLOOR DIFFUSERS UNDERFLOOR FN POWERED TERMINL UNITS UNDERFLOOR FN UNITS ENGINEERING GUIDE ND
More informationInstallation Instructions
Instructions for Dryers Original Instructions Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.) www.speedqueen.com Part No. 54320R October
More informationGENERAL CONTRACTOR NOTES GEN WALK-IN NOTES 1. E.C. TO VERIFY EXACT SIZE & LOCATION OF COMPRESSORS FOR WALK-IN BOXES W/ KEC & ARCHITECT.
GENERAL CONTRACTOR NOTES 78 79 00 7 SF 00 80 30 Blake Street, Suite 00, CO 8005 303.86.8555 05 Main Street, Unit C0 Edwards, CO 863 9.96.8960 75 76 WARMING KITCHEN BEVERAGE 8 66 6 SF 5. E.C. TO VERIFY
More informationSOUTHERN PRIDE VSP HOOD
OPERATOR MANUAL IMPORTANT INFORMATION, KEEP FOR OPERATOR This manual provides information for: SOUTHERN PRIDE VSP FOR A SOUTHERN PRIDE BBQ OVEN UL file # for Southern Pride oven MH943 UL file # for Avtec
More informationE64000LC SERIES ! INTENDED FOR DOMESTIC COOKING ONLY! READ AND SAVE THESE INSTRUCTIONS
INSTLLTION INSTRUCTIONS H0072 E64000LC SERIES! INTENDED FOR DOMESTIC COOKING ONLY! RED ND SVE THESE INSTRUCTIONS INSTLLER: LEVE THIS MNUL WITH HOMEOWNER. HOMEOWNER: USE ND CRE INFORMTION ON PGES 3 & 4.
More informationINSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More information2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS
City of Redwood City Community Development Department Building and Inspection Department 1017 Middlefield Road Redwood City, CA 94063 Phone (650) 780-7350 2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY
More informationINSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationMERIT SERIES Upflow / Horizontal
PRODUCT SPECIFICTIONS GS FURNCES ML80UH MERIT SERIES Upflow / Horizontal Bulletin No. 20590 February 208 Supersedes November 207 FUE - 80% Input - 44,000 to 32,000 Btuh Nominal dd-on Cooling - 2 to 5 Tons
More informationInstallation Instructions
Instructions for Dryers Original Instructions Keep These Instructions for Future Reference. CAUTION: Read the instructions before using the machine. (If this machine changes ownership, this manual must
More informationCOPPER INSERT INSTALLATION INSTRUCTIONS, USE AND CARE GUIDE
COPPER INSERT INSTALLATION INSTRUCTIONS, USE AND CARE GUIDE DESIGNER SERIES MODELS Model Width CFM Type of Motor & Blower VSL430 BF 28-3/8" * Remote VSL436 BF 34-3/8" * Remote VSL442 BF 40-3/8" * Remote
More informationIndirect Gas-Fired Make-Up Air
Indirect Gas-Fired Make-Up Air Model IG 800 to 7,000 cfm Up to 400,000 Btu/hr Multiple Furnace Control Options Optional Evaporative Cooling May 20041 Product Features Model IG Indirect Gas-Fired Make-Up
More informationE64000 SERIES INTENDED FOR DOMESTIC COOKING ONLY
INSTLLTION INSTRUCTIONS H007 E64000 SERIES INTENDED FOR DOMESTIC COOKING ONLY!! RED ND SVE THESE INSTRUCTIONS INSTLLER: LEVE THIS MNUL WITH HOMEOWNER. HOMEOWNER: USE ND CRE INFORMTION ON PGES 3 ND 4. roannutone
More information1 Exam Prep. NFPA 90 B Questions
1 xam Prep NFP 90 Questions 1. onnectors are more restricted and are generally limited to? 14 feet 14 inches 2 feet 1 foot 2. Where a hand-fired, solid fuel-burning furnace is equipped with a fan to circulate
More informationINSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationGas-Fired Indoor and Outdoor Duct Furnaces
July, 2008 Gas-Fired Indoor and Outdoor Duct Furnaces INDOOR GRAVITY VENTED DFG, DBG, DCG INDOOR SEPARATED COMBUSTION DFS, DBS, DCS OUTDOOR GRAVITY AND POWER EXHAUSTED H Series table of contents A complete
More informationSection (CSI ) I-Series Drum & Tube (04/23/10) Indirect-Fired Heating & Ventilating
Section 15700 (CSI 23 74 33) I-Series Drum & Tube (04/23/10) Indirect-Fired Heating & Ventilating Note: Optional items and/or items requiring a choice, will be shown between brackets and/or parentheses
More informationGUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION)
GUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION) February, 2017 Contents Clauses Page 1. Basic Concepts 1 2. Design Considerations 1 3. Car Parks Ventilation 2 4. Kitchen
More informationInstallation Instructions
Instructions for Dryers Original Instructions Keep These Instructions for Future Reference. CAUTION: Read the instructions before using the machine. (If this machine changes ownership, this manual must
More informationCHAPTER 8 CHIMNEYS AND VENTS
CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.
More informationThe D1000. Typical Specifications: activate the mechanical fire suppression system. (pressurized potassium citrate / potassium acetate mix)
Fan 10 Ductwork Cabinet 7 to 10 adaptor set Range Hood Fan D1000-I_-DF Air Flow Plenum Ready Supply Cable to Fan 120VAC Input Supply Line 120VAC Output Line, Power Disconnect D1000-I_-DF-NFPA101 12 Ductwork
More informationSECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM
PART 1 GENERAL 1.01 SUMMARY SECTION 15371 KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM A. Section Includes: A complete wet chemical automatic fire suppression system for the exhaust hood, including necessary
More informationInternal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.
A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall
More informationUNIVERSITY OF MISSOURI Central Station Air-Handling Units March
GENERAL: 1. This section provides criteria for the design and installation of air handling units. DESIGN GUIDELINES: Design General 1. Location 1.1. For new construction, and existing buildings where possible,
More informationFront Load Washer FAFW3801L W
Front Load Washer FFW380L W 5 Wash ycles 3.26 u. Ft. D.O.E. Height 36" Width Depth 29-3/4" More Easy To Use Features Designed for quiet operation. Stay-Fresh Door Seal Optional Pedestal Drawer ENERGY STR
More information2015 IRC Significant Changes For Mechanical and Fuel Gas with LSUCCC Amendments
2015 IRC Significant Changes For Mechanical and Fuel Gas with LSUCCC Amendments Based on the International Residential Code (IRC ) GR PPN 1208 Course Approval # 12085 Description This seminar reviews and
More informationInspection Checklist Residential Mechanical Rough In July 2016
Inspection Checklist Residential Mechanical Rough In July 2016 This Inspection Checklist reflects code requirements of the 2015 International Residential Code (IRC), the 2015 Uniform Plumbing Code (UPC),
More informationLand Use and Environmental Service Agency (Code Enforcement) Mechanical Q&A 2007
General: 1) (Q) May the gas be turned on temporarily to the gas piping system without the installation of the appliance? (A) NO! 2) (Q) Are traps required on all condensate drains from equipment? (A) Only
More informationProduct Dimensions Page 1 of 7. DA Downdraft Ventilation Hood
Product Dimensions Page 1 of 7 Location Codes 1 DAG 500 Internal blower The blower box can be mounted in such a way that the vent collar is aligned to the left, the right, downwards or towards the rear,
More information