Danfoss gas detection Controller unit
|
|
- Blaze Robbins
- 5 years ago
- Views:
Transcription
1 Data sheet Danfoss gas detection Controller unit The gas detection Controller Unit is used for a centralized monitoring and warning of hazardous gas concentrations. The input signals for the controller are collected from the local gas detection units of the types Basic, Premium and Heavy Duty via S85 Fieldbus or Analog communication. In total 96 gas detection sensors can be handled via Fieldbus + via Analog directly on the controller (+8 additional possible if expansion modules added). The Controller Unit comes with alarm relays available for external looped alarm devices. Additional relays and sensor wiring loops is possible by adding Expansion modules to the controller. Each local gas detection unit is assigned a unique address in the Controller and by continuous communication with the individual GDU s the Controller reacts on alarm signals from the local GDU. The parameter setting and the actual state of each local GDU can be read in the Controller display. Features For connection of up to 96 sensors via fieldbus + via Analog (when 7 expansion modules added) Easy configuration via intuitive user-interface; helps simplify operator handling and minimize risk of operational setting errors Simple commissioning by standard parameter configuration Flexible connection to local gas detection units by either Analog or S85 fieldbus communications Fieldbus wiring: Wire length up to 900 meters (95 ft.) per segment. relays for external alarm device circuits Up to 7 Expansion modules possible; allows additional 7 segments with a total of 700 meters (6 ft.) wiring and a total of relays for alarm device circuits. Automatic self-diagnostics to ensure correct communication and operation for communication error 6 menu languages Password protected settings allowing authorized access only Service alerts on display Conformity to EN Enables regulatory compliance with EN 78:06, ISO 59:0, AI758805en-0000 DKCI.PD.S00.G.0
2 Contents Page Features... Specifications... Electrical connection... Fieldbus loop...5 Ordering...6 AI758805en-0000 DKCI.PD.S00.G.0
3 Specifications Electrical Power supply V DC ± 0 % Power consumption ( V DC) W, 50 ma Analog input () to 0 ma, overload and short-circuit- protected, input resistance 00 Ω Tension for external analog transmitter V DC (same as power supply), max. 00 ma / per sensor Analog output () configurable for each input Proportional, overload and short-circuit- protected, charge 500 Ω - 0 ma = measuring range.0 < ma = underrange >0. ma = overrange.0 ma = fault Alarm relay () 50 V AC, 5 A, potential-free, change-over (SPDT) Fault relay () 50 V AC, 5 A, potential-free, normally open contact (SPST) Visualization LCD Status LED () Operation Menu language (selectable) Interface fieldbus Transceiver Gases Digital and analog sensors for toxic, combustible & refrigerant gases Environmental Humidity Working temperature Storage temperature Two lines, 6 characters each, illuminated Operation fault st alarm nd alarm 6 push-buttons German, English, Dutch, USA, French, Swedish S 85 / 900 Baud 5 95 % H non-condensing -5 C to +0 C ( F to 0 F) 0 C to +0 C ( F to 0 F) Physical Enclosure Plastic housing ABS Colour AL 705 Protection class IP 0 Weight 0. kg (0.8 lb.) Packaging volumes Ca.. l Mounting Top DIN rail mounting, installation in distribution box Dimensions (Controller unit) (W x H x D) 06 x 0 x 6 mm (. x. x. in.) Dimensions (Controller Solution) (W x H x D) 98 x 0 x 0 mm (.7 x 6.5 x 5.5 in.) Wire connection: Power supply... Output... Screw type terminal:.5 mm ( AWG) x spring type terminal: min. 0.5 mm, max..5 mm ( to 6 AWG) Input... Spring type: min. 0.5 mm, max..5 mm ( to 6 AWG) Guidelines EMC Directive 0/0/EU Low voltage directive 0/5/EU CE EN 5055-, EN 507 Interface ModBus TU S 85 Function Transmission of current and average values, alarm and relay status, and analog output states in MODBus TU S 85 protocol to external devices AI758805en-0000 DKCI.PD.S00.G.0
4 Electrical connection Fault A 06 A 0 A 0 A 0 X 5 X_Bus X_Bus X 5 6 X D D D D D F Digital output Controller unit Danfoss 8H_0-08 Power/ Main Bus X0 + - Main Bus_A A Main Bus_B B X < Power Field Bus Analog input < X Field Bus_A A Field Bus_B B AI_0 AI_0 AI_0 AI_0 Analog output AO_0 AO_0 DI_0 Digital input DI_0 DI_0 DI_ Main Bus_A A Main Bus_B B A J5 port available on the controller. Field Bus_A A Field Bus_B B B -0 ma -0 ma -0 ma -0 ma AP 0 AP 0 AP 0 AP 0 AI758805en-0000 DKCI.PD.S00.G.0
5 Fieldbus loop Each GD controller can handle up to 96 sensors and handle any mix of individual Gas detection units of the types Basic, Premium and Heavy Duty. The max. recommended loop wire length is 900 meter (95 ft) per segment. With additional segments (and additional controller expansion modules) the max recommended loop wire length is 700 meter (6 ft). The controller and the last GDU in each segment must be provided with a resistor of 560 Ohm. A Umin of 6 V DC must be secured at any spot in the loop. Below figure shows how to make proper connections between the controller and each GDU. Controller Unit unit 560 GDU Addr. 05 GDU Addr. 0 Danfoss 8H9_ V DC V DC BUS_B BUS_A 0 V DC V DC GDU Addr. 0 GDU Addr. 0 GDU Addr. 0 U min = 6 V DC Wire length max. 900 meter (95 ft) per segment. Wire length max. 900 meter (95 ft) per segment. More More segments segments with with additional additional expansion expansion modules modules max. 700 max. meter 700 (6 meter (6 ft). ft). Additional power power limitations limitations must must be calculated. be calculated. IGHT Controller unit = Terminating resistor Ohm Ohm = GDU (Basic, Premium and/or and/or Heavy Heavy Duty) Duty) Controller unit WONG Danfoss 8H_0-08 AI758805en-0000 DKCI.PD.S00.G.0 5
6 Ordering Description Code number Controller unit Controller solution (controller + enclosure) Controller solution Uptime Warning module (wire break monitoring module) Controller expansion module Gateway for controller 8H6 8H6 8H67 8H6 8H6 8H68 Controller solution Controller unit placed in an enclosure ready to be connected to a power source. A separate UPS for the controller is available. Gateway for controller The gateway is an addition to the controller and used for communicating via Modbus TCP/IP. Warning module (wire break monitoring module) The warning module is used for monitoring the circuiting to the warning/alarm devices on a centrally controlled gas detection system. Wire breaks or wire interruptions in the alarm device loop will be reported to the central control. Controller expansion module The gas detection Controller Expansion module is used for expansion of the cable coverage in terms of number of loops and the total wire length. Each Controller Unit can handle up to 7 Expansion modules allowing additional 7 segments with a total of 700 meters (6 ft.) wiring and a total of relays for alarm device circuits. AI758805en-0000 DKCI.PD.S00.G.0 6
7 AI758805en-0000 DKCI.PD.S00.G.0 7
8 AI758805en-0000 DKCI.PD.S00.G.0 8
Gas Controller Module GC-06
Page 1 Oct. 2015/2 Measuring, warning and controlling module for toxic, combustible and refrigerant gases and vapours. The gas controller series GC-06 is designed in accordance with the standard EN 50545-1.
More informationDanfoss gas detection unit Type GD Heavy Duty
Data sheet Danfoss gas detection unit Type GD Heavy Duty The Heavy Duty gas detection units are used for monitoring and warning of hazardous Ammonia gas concentrations. They are intended for ATEX/ IECEx
More informationDanfoss gas detection units
Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning
More informationDanfoss gas detection units
Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning
More informationMulti-Gas-Controller MGC2
Page 1 Aug. 2018 Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology for continuous monitoring of the ambient air to detect toxic and combustible gases, refrigerants
More informationRecalibrate the way you look at gas detection
Catalogue Gas detection solution Recalibrate the way you look at gas detection Next generation gas detection for industrial refrigeration The next generation of Danfoss gas detectors are based on a digital
More informationPolyGard Digital Gas Controller DGC-05 RS-485 Bus
PolyGard Digital Gas Controller DGC05 RS485 DESCRIPTION Gas measuring controller series for continuous monitoring and warning of toxic, combustible and refrigerant gases and vapours. The gas controller
More informationTwo-Channel Gas Controller
Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously
More informationEKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual
EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING Manual Contents Introduction...3 Valve compatibility...3 Features...3 Application examples...3 Ordering...3 Operating the EKC 347...4-5
More informationDigital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6
Digital Gas Transmitters with Auxiliary s & Control Specifications subject to change without notice. USA 181011 Page 1 of 5 DESCRIPTION Digital RS-485 communicating, addressable toxic and combustible gas
More informationPolyGard Single Point Controller SPC-X3-34XX for Combustible Gases
PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases DESCRIPTION Gas measuring and monitoring controller based on stateof-the-art microtechnology with integrated sensor for continuous monitoring
More informationPolyGard 2-channel Gas Controller MGC-03
PolyGard 2-channel Gas Controller MGC-03 DESCRIPTION Gas measuring and monitoring controller based on state-ofthe-art micro-technology with integrated buzzer for continuous monitoring of the ambient air
More informationOxygen (O2) Single-Point Gas Detection System
Oxygen (O) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in oxygen (O) sensor, accepts one analog remote device such as a secondary gas sensor, temperature or humidity
More informationGas Detection Unit (GDU) GDA, GDC, GDHC, GDHF, GDH
896 Installation Guide Gas Detection Unit (GDU) GDA, GDC, GDHC, GDHF, GDH Technician use only! This unit must be installed by a suitably qualified technican who will install this unit in accordance with
More informationPolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours
PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor
More informationNitrogen Dioxide (NO2) Single-Point Gas Detection System
Nitrogen Dioxide (NO) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in nitrogen dioxide (NO)/diesel fume gas sensor, accepts one analog remote device such as a secondary
More informationPolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen
PolyGard Single Point Controller SPC-X3-XX for Toxic Gases and Oxygen DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor and
More informationSensor unit MC2 with analog output for Freon gases and refrigerants
Page 1 Dec. 2018 Sensor unit MC2 with analog output for Freon gases and refrigerants Exchangeable sensor unit including digital value processing and self control for the continuous monitoring of the ambient
More informationRefrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301
Refrigeration and Air Conditioning Technical leaflet Electronic controller EKC 201 and EKC 301 RC.5L.A1.02 RC.5L.A2.02 09-1998 Introduction EKC 201 and 301 are used for temperature control compressor control
More informationNitrogen Dioxide Stand-Alone Detector - Analog, ModBus
Features Internal function monitoring with integrated hardware watchdog Hardware and software according to SIL2 compliant development process Easy maintenance / calibration by replacing the sensor cartridge
More informationGM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /
3 GM20 Digital Ground Continuity Relay For AC Systems Technical Bulletin NAE03230 / 0.20 GM20 Ground continuity monitor For AC systems Description The GM20 monitors the loop resistance of ground conductors
More informationDipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Phone: 040 807-0 Fax: 040 807-259 Alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC display
More informationCarbon Monoxide CO Transmitter ADT-X3-1110
Page 1 Sep. 2017 CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air to detect carbon monoxide concentrations (CO).
More informationCarbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output
Features Electrochemical sensor element (0)2-10 Vdc or (0)4-20 ma output, jumper selectable Standard IP65 plastic enclosure Measuring ranges 0-50 ppm 0-100 ppm 0-150 ppm 0-200 ppm 0-250 ppm 0-300 ppm 0-500
More informationCombustible Gas Detection and Control System
Combustible Gas Detection and Control System DESCRIPTION Gas monitor with built-in combustible gas sensor, wall-mounted, accepts inputs from remote devices such as other gas sensors, temperature or humidity
More informationGas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2
Features Integrated (built-in NO2 sensor / detector (Electro chemical sensor type Measuring ranges 0-10 ppm, 0-20 ppm or 0-30 ppm LCD display to show actual in ppm Status LED indication Normal operation
More informationFire control panel detect 3004 plus and accessories
Fire control panel detect 3004 and accessories The modular fire alarm panel detect 3004 is the basic version of a broad product portfolio of the system detect 3000. Up to 20 fire control panels can be
More informationEngineering Guideline. pac- Carriers Type Universal
Engineering Guideline pac- Carriers Type 9195 Universal Integration of conventional process automation interfaces pac- Carrier The pac- Carrier reflects the intention of R. STAHL to provide state-of-the-art
More informationRemote alarm indicator and test combination MK2430
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Tel.: 040 807-0 Fax: 040 807-259 Remote alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit
ABB MEASUREMENT & ANALYTICS DATA SHEET C50 1/16 DIN controller / alarm unit 2 C50 1/16 DI N CON TROLL ER / AL ARM U NIT DS/C 50-E N RE V. M Measurement made easy C50 the 1/16 DIN controller to suit your
More informationUser Manual. PolyGard Gas Controller MGC3. Two-Channel Analog Gas Controller Serial Number _E _0907. September 2007
PolyGard Gas Controller MGC3 Two-Channel Analog Gas Controller Serial Number _E _0907 User Manual September 2007 January 04, 2016 Revision Specifications subject to change without notice. USA 160104 Page
More informationHigh Pressure Conductivity Monitor
Product Data Sheet PDS 71-EDS880/1/rev.A August 2006 Model EDS880/1 High Pressure Conductivity Monitor COMPLETE SYSTEM FOR THE DETERMINATION OF CONDUCTIVITY IN HIGH PRESSURE SYSTEMS SENSOR INSTALLS DIRECTLY
More informationProcess Alarm Module RTA 421
Technical Information TI 074R/24/ae Process Alarm Module RTA 421 Alarm module and power supply for monitoring current or voltage signals Application Areas Plant and machine construction Panel builders
More informationABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements
Specifications COMMANDER 150 Universal Process Indicator High visibility 6-digit LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement
More informationTYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM
2 Line, 16 Characters/row LCD Display Temperature Input Range -50 C to +500 C -58 F to + 932 F Enclosure NEMA Type 4X Current Rating 30A max (resistive load only) Ambient Temperature -40 C to + 40 C -40
More informationEngineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules
Engineering Guideline pac-carriers Type 9195 SIEMENS ET-200M Fail-safe signal modules pac-carrier Type 9195 2 Engineering Guideline/SIEMENS 19.05.2015 pac-carrier Type 9195 Integration of conventional
More informationSUPREMATouch. Modular Fire & Gas Detection System
SUPREMATouch Modular Fire & Gas Detection System Tel: +44 (0)8 9388 Email: info@ Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel
More informationCarbon Monoxide Transmitter
Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or
More informationSUPREMATouch. Modular Fire & Gas Detection System
SUPREMATouch Modular Fire & Gas Detection System Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel from hazardous gases in
More informationRS485 MODBUS Module 8AI
Version 1.4 15/04/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationisopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)
T M 1 isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) Technical Bulletin NAE1012372 / 03.2015 isopv
More informationRTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals
Technical Information RTA421 Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals Application Plant and machine construction Panel builders Process monitoring Process
More informationISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)
ISOSCAN EDS460/490 EDS461/491 Insulation fault locators with control and display function for EDS systems (insulation fault location systems) EDS460-490_D00085_01_D_XXEN/01.2017 ISOSCAN EDS460/490 EDS461/491
More informationECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys
ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark Description ECL Comfort 210 controller series ECL 210 The ECL Comfort 210 is an electronic weather
More informationISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances
ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances _D00108_00_D_XXEN/05.2015 ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances
More informationInsulation fault evaluator EDS460-DG
Insulation fault evaluator for localising insulation faults in DC IT systems with a number of branch circuits where high system leakage capacitances are involved Preliminary data sheet TDB108021en/09.2008
More informationC SINGLE-POINT HEAT-TRACING CONTROL SYSTEM PRODUCT OVERVIEW
SINGLE-POINT HEAT-TRACING CONTROL SYSTEM PRODUCT OVERVIEW SHIFT TEST SHIFT C910 SERIES ALARM MONITOR CONFIG BACK ENTER PROGRAMMABLE SINGLE POINT HEAT-TRACING CONTROLLER HEAT-TRACING CONTROLLER STATUS ALARM
More informationLINETRAXX RCMS460-D/-L RCMS490-D/-L
LINETRAXX RCMS460-D/-L RCMS490-D/-L Multi-channel AC, pulsed DC and AC/DC sensitive residual current monitors for earthed AC, DC and AC/DC systems (TN and TT systems) RCMS460-490_D00067_0_D_XXEN/09.207
More informationModel D12-IR. Digital Gas Transmitter...
Model D12-IR Digital Gas Transmitter... ATI s Series D12 gas transmitter line now includes a versatile Infrared system that can be configured for LEL or select toxic gases. The D12-IR utilizes a compact
More informationAPPLICATION DATA SHEET
APPLICATION DATA SHEET Control Systems Transmitters Sensors Accessories Wall, 19 Rack or Panel Mounting Units 110/230V 50/60Hz AC operation 250 Addressable devices as: Relays, 4-20 Inputs or Gas Detectors
More information1.7. Insulation fault evaluators EDS460/490 EDS461/491
Bender Incorporated 700 Fox Chase, Coatesville PA 1930 Tel.: (800) 356-466 Fax: (610) 383-7100 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control function
More informationIGD.CO.UK
APPLICATION DATA SHEET S p e c i f i c a t i o n 2 SO22 WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700+ D e t e c t o r Website: C o n t r o l P a n e l - Wall mounting or 19 Rack
More informationDetectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.
Détecteur de gaz OLCT80 Detectors-Transmitters for Flammable, Toxic Gases and Oxygen Non-intrusive operation via intrinsically safe infrared remote control Disponible en version déportée, ADF ou de SI
More informationPANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm
PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM Card Rack Modules CABLE DUCT MAIN SWITCH 800 mm USER INTERFACE TERMINAL PRODUCT OVERVIEW The nvent
More informationZIOU/230 - MAINS IO INSTRUCTION MANUAL
Description ZIOU/230 - MAINS IO INSTRUCTION MANUAL The Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third party equipment with the Fire Alarm Control panel
More informationC SINGLE-POINT HEAT-TRACING CONTROL SYSTEM. product overview
C910-485 SINGLE-POINT HEAT-TRACING CONTROL SYSTEM product overview ALARM SHIFT TEST C910 SERIES MONITOR CONFIG BACK ENTER PROGRAMMABLE SINGLE POINT HEAT-TRACING CONTROLLER STATUS ALARM OUTPUT The DigiTrace
More information1.7. Insulation fault evaluators EDS460/490 EDS461/491
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 06401 807-0 Fax: 06401 807-59 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control
More informationGMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly
Operation Manual GMA200-MT Gas detection controller for mounting rail assembly GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, Germany TEL. +49 / (0)231 / 564 00 0 FAX +49 / (0)231
More information910 Series Single-point heat-tracing control system
Single-point heat-tracing control system 910*E1FWL*SSR2 Product overview The Raychem 910 is a compact, full-featured, microprocessor-based, single-point heat-tracing control system. The 910 provides control
More informationMYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7
MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7 VISIT OUR WEBSITE SIGMACONTROLS.COM MYRIAD DPC MANUAL 013114 1 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features
More informationTouchpoint Plus. A whole new control experience
Touchpoint Plus A whole new control experience Touchpoint Plus Delivering reliable control Honeywell reliability from the most trusted experts in gas detection Built-in battery backup for constant uptime
More informationAPPLICATION DATA SHEET
APPLICATION DATA SHEET Wed : www.saenchotesei.com WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 920 - Wall, 19 Rack or Panel Mounting Units - 110/230V 50/60Hz AC operation - 250 Addressable
More informationWARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro
A d e v i h c r D c o n e m u WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free from defects in workmanship
More informationNGC-40 Advanced Heat-Tracing Control System
NGC-40 Advanced Heat-Tracing Control System Local configuration and monitoring with Raychem Touch 1500 touch screen display Heat-tracing system NGC-40 system Remote configuration and monitoring with Raychem
More informationRAYCHEM NGC-30 COMPONENTS
PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM PRODUCT OVERVIEW CABLE DUCT Card Rack Modules TERMINAL STRIP PLINTH MAIN SWITCH 800 mm USER INTERFACE
More informationisopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)
T M 1 isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) Technical Bulletin NAE1012670 / 08.2013 isopv425
More informationMEAS CAL ALARM WASH CONF APT4000 TC
APT4000 Series Toroidal Conductivity Transmitters Overview 70-82-03-42 3/01 Page 1 of 8 Specification The Honeywell Analytical Process Transmitter (APT) 4000 Series transmitter continuously measures conductivity,
More informationAH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER
AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER MODEL AH3 7 P - - A AH3000 series conforming to CE, UL and CSA are 180mm pen type hybrid recorders with a simultaneous display of multi-channel data,
More information920 Series. A dry contact relay is provided for alarm annunciation back to a distributed control system (DCS).
Product overview The DigiTrace 920 is a compact, full-featured, microprocessor-based, multipoint heat-trace controller. The 920 provides control and monitoring of two independent electrical heat-tracing
More informationMaster devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems
X X testregistrierung Type Web server, also for mobile devices Zone modules Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X-AIRCONTROL zone
More informationWarranty Registration
WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free from defects in workmanship and materials for a period
More informationRVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating
2 526 Heating Controller including dhw heating Series C RVL472 Multifunctional heating controller for use in residential and non-residential buildings Suited for: Heating zone control with or without room
More information/8 DIN Level Indicator
Data Sheet SS/_6 High visibility 5-digit LED display clear and accurate indication Analog and relay outputs as standard high, low, latch and rate alarms, plus isolated retransmission Maths functions included
More informationECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark
ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark Description ECL Comfort 210 controller series The ECL Comfort 210 is an electronic weather compensated
More informationDräger Polytron 8310 IR Detection of flammable gases and vapour
Dräger Polytron 8310 IR Detection of flammable gases and vapour The Dräger Polytron 8310 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit
More informationP R O D U C T D ATA S H E E T
P R O D U C T D ATA S H E E T www.internationalgasdetectors.com Transmitters Control Systems Sensors Accessories TOCSIN 90 SYSTEM UPGRADE Use existing MK3 Pellistor Flammable Gas Sensors and upgrade to
More informationMEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2
APT2000 Series 2-Wire Contacting Conductivity Transmitters Overview The Honeywell Analytical Process Transmitter (APT) 2000 Series transmitter is a two-wire 24-Volt device that continuously measures conductivity,
More informationAdvanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly
Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O Features Assembly System integration kit for Advanced Diagnostics PCS integration via Diagnostic Manager or device DTM Simple automatic
More informationModBus DE-1 INSTALLATION AND USER MANUAL
ModBus DE-1 INSTALLATION AND USER MANUAL INTESIS Software, SL Distributed by DURAN ELECTRONICA S.L Tomás Bretón 50 28045 MADRID, España duran@duranelectronica.com www.duranelectronica.com 2 2010 DURAN
More informationDräger Polytron 8100 EC Detection of toxic gases and oxygen
Dräger Polytron 8100 EC Detection of toxic gases and oxygen The Polytron 8100 EC is Dräger s top of the line explosion-proof transmitter for the detection of toxic gases or oxygen It uses a high performance
More informationGas Detection System TOX ALARM DG2000-Garage
Gas Detection System TOX ALARM DG2000-Garage Gas Detection System 32 independent programmable channels 2 programmable alarm levels for each gas = up to 6 for each channel LCD alphanumeric display of gas
More informationSUPREMATouch Modular Fire & Gas Detection System
SUPREMATouch Modular Fire & Gas Detection System Because every life has a purpose Class Leading Fire & Gas Detection Solutions MSA s permanent gas detection systems are relied upon by a huge number of
More informationToroidal Conductivity Transmitters Series APT4000 Specifications
Toroidal Conductivity Transmitters Series APT4000 Specifications 70-82-03-42 March 2001 Overview The Honeywell Analytical Process Transmitter (APT) 4000 Series transmitter continuously measures conductivity,
More informationDräger REGARD 3900 Series Control System
Dräger REGARD 3900 Series Control System The devices of the Dräger REGARD 3900 series can be used as standalone controllers You can configure up to 16 measuring channels In addition, the modular setup enables
More informationACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System
SHIFT TEST BACK ENTER C910 SERIES STATUS OUTPUT ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM ACS-30 System MONITOR CONFIG POWER CONTROL MODULE ACCS-PCM-5 PROGRAMMABLE SINGLE POINT HEAT-TRACING CONTROLLER
More informationProducts and performance
Products and performance February 26, 2016 GfG Instrumentation overview of fixed system products Slide 1 GfG Instrumentation, Inc. 1194 Oak Valley Drive, Suite 20, Ann Arbor, Michigan 48108 Toll free (USA
More informationUser Manual. PolyGard Single Point Controller SPC-43-20XX. Single Point Gas Controller for Refrigerant Gases Serial Number _E_.
PolyGard Single Point Controller SPC-43-20XX Single Point Gas Controller for Refrigerant Gases Serial Number _E_ User Manual January 2015 Phone: 0049(0)8531/9004-0 Fax: 0049(0)8531/9004-54 Specification
More informationGMA200-MW16. Operation Manual. Gas detection controller for wall mounting
Operation Manual GMA200-MW16 Gas detection controller for wall mounting GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, GERMANY TEL. +49 / (0)231 / 564 00 0 FAX +49 / (0)231 / 516 313
More informationHTC-915-CONT. Heat-Trace Control system
Heat-Trace Control system Product overview The Raychem HTC-915 system is a compact, full-featured microprocessor-based single-point heat-trace controller. The HTC-915-CONT provides control and monitoring
More informationDräger Polytron 8200 CAT Detection of flammable gases and vapors
Dräger Polytron 8200 CAT Detection of flammable gases and vapors The Dräger Polytron 8200 CAT is an advanced explosion proof transmitter for the detection of flammable gases in the lower explosion limit
More informationInstructions for the fan motor control system with integrated wiring terminals SILVER C
Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.
More informationGAS PLUS ALARM SYSTEM
GAS PLUS -IR SERIES 4688-IR COMBUSTIBLE GAS OR CARBON DIOXIDE TRANSMITTER GAS PLUS -IR TRANSMITTER SERIES 4688-IR COMBUSTIBLE GAS OR CARBON DIOXIDE TRANSMITTER The Scott Gas Plus -IR Model 4688 IR Gas
More informationIndustrial Grade Gas Detection Detecting The Difference
detcon inc. Industrial Grade Gas Detection Detecting The Difference PO Box 8067 The Woodlands, TX 77387 888-367-4286 (toll free) 713-559-9200 281-292-2860 (fax) sales@detcon.com Catalog #CB-0409 www.detcon.com
More informationToxic Gas Detection. Model F12. Toxic Gas Detection
Toxic Gas Detection Model F12 Toxic Gas Detection Smart Sensor Technology The Series F12 Gas Transmitter is an Intrinsically Safe (IS) version of our explosion-proof D12 transmitter. In its standard form,
More informationCapacity controller EKC 331T REFRIGERATION AND AIR CONDITIONING. Manual
Capacity controller EKC 331T REFRIGERATION AND AIR CONDITIONING Manual Introduction Application The controller is used for capacity regulation of compressors or condensers in small refrigerating systems.
More informationIndustrial Grade Gas Detection
Industrial Grade Gas Detection DETECTING THE... Difference Catalog #CB 0112 detcon inc. an company www.detcon.com Houston Odessa Shanghai Dammam Del Carmen Europe Company Profile ISO 9001: 2008 Certified
More informationLC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT
LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT Simply Features In Brief Telemetry Ready Security 2 or 3 Pump Control UL Listed Alarm/Event Log Volumetric Flow Calculator VFD Control Optional Dialer
More informationCOMFORT IP: Room Control Unit Radio with Display
COMFORT IP: Room Control Unit Radio with Display The COMFORT IP Room Control Unit Radio with display registers the room temperature and the humidity in the assigned heating zone and regulates it via connected
More informationDEB71. Earth Leakage Monitoring Relay. Benefits. Description
Earth Leakage Monitoring Relay Benefits Adjustable trip level. Adjustable leakage threshold from 30mA to 5A or from 300mA to 30A. 2 outputs. Two relay outputs provide, besides the alarm signal an additional
More informationIndustrial Grade Gas Detection
Industrial Grade Gas Detection DETECTING THE... Difference Catalog #CB 0912 detcon inc. an company www.detcon.com Houston Odessa Shanghai Dammam Del Carmen UK Company Profile ISO 9001: 2008 Certified 105-A
More information