ModBus DE-1 INSTALLATION AND USER MANUAL

Size: px
Start display at page:

Download "ModBus DE-1 INSTALLATION AND USER MANUAL"

Transcription

1 ModBus DE-1 INSTALLATION AND USER MANUAL INTESIS Software, SL Distributed by DURAN ELECTRONICA S.L Tomás Bretón MADRID, España

2 DURAN ELECTRONICA ALL rights reserved -

3 TABLE OF CONTENTS 1. ModBus DE-1 GATEWAY PRESENTATION HOW TO PURCHASE A ModBus DE-1 CONVERSOR FOR EUROSONDELCO/SIEMENS CC62P EUROSONDELCO/SIEMENS CC62P. Presentation PREREQUISITES FOR THE PROPER FUNCTIONING OF THE ModBus DE FUNCTIONAL CHARACTERISTICS OF THE ModBus DE ModBus REGISTER MAP DESCRIPTION OF ModBus REGISTER CONTENTS DEVICE DIMENSIONS EQUIPMENT CONFIGURATION PROJECT SELECTION CONSOLE PORT SELECTION. CONFIGURATION AND CONNECTION SELECTION OF ModBus CONFIGURATION. INTESISBOX CONFIGURATION DOWNLOAD CONFIGURATION INTO EQUIPMENT VIEW SIGNALS VIEW Bus DEGD VIEW Bus ModBus TECHNICAL CHARACTERISTICS...18 I-manModBusDE1-vo1 3

4 DURAN ELECTRONICA ALL rights reserved -

5 1. ModBus DE-1 GATEWAY PRESENTATION IntesisBox is a device that integrates the EUROSONDELCO/SIEMENS CC62P control panel through a ModBus RTU (remote terminal) or ModBus TCP/IP. Along with the device, a 1,8 meter DB9male-DB9female standard cable is supplied to connect directly to a PC serial port for configuration and monitoring of the device. 2. HOW TO PURCHASE A ModBus DE-1 CONVERSOR FOR EUROSONDELCO/SIEMENS CC62P? Contact DURAN ELECTRONICA S.L or one of its distributors directly and request one. Once your purchase order has been accepted, you will receive the equipment along with an with the link to download the free configuration software. international@duranelectronica.com 3. EUROSONDELCO/SIEMENS CC62P. Presentation EUROSONDELCO/SIEMENS CC62P is a system for detection and measurement of toxic and explosive gases using electrochemical, catalytic and infrared technology. A modular system, expandable from 1 to 4 module lines, allows for the connection of 16 detectors per module line with a maximum capacity of 64 detectors. Every module line may be configured in 1, 2 or 4 toxic gas detection groups -1 dry contact relay per group/gas- or 1, 2 groups -2 relays per group/gas- for explosive gases. Independent programming of ventilation and alarm levels per group. Communication protocol RS485. Compatible with 4-20mA detectors -through optional interface-. Two reading modes per module line -sequential and maximums- and events memory. General alarm output for toxic gases. General failure output. Completely programmable and easy to install: no special instrumentation. Complies with the most relevant European regulations for CO detection. 4. PREREQUISITES FOR THE PROPER FUNCTIONING OF ModBus DE-1 1. ModBus DE-1 software is available in Spanish and English languages only. Remember that on the control unit you must select the language corresponding to the license you have acquired (Spanish or English); if you do not, you will not correctly receive messages in the ModBus DE-1 2. The control unit must be readied for integration. Remember you must indicate that the control unit will be integrated when placing your order. I-manModBusDE1-vo1 5

6 3. Regulations that can be integrated are SPANISH or INTERNATIONAL/PORTUGUESE. Other detection regulations cannot be integrated. 4. The control unit is configured by default with the SEQUENTIAL reading mode. Configuration in this reading mode is essential for the control unit to cyclically send the measurings from all installed detectors. 5. FUNCTIONAL CHARACTERISTICS OF THE ModBus DE-1 Supported ModBus functions The registers are available as input registers (40000) or holding registers (30000), therefore functions 03 and 04 (read holding registers and read input registers) are supported for reading the registers. ModBus error codes are supported, being sent every time a non-valid function is requested. ModBus register format ModBus registers are 2 bytes (16 bits), with the bytes ordered MSB..LSB, and with a 16 bits format with no sing. Maximum number of registers read in a single data packet is 125. Total number of registers with information is 233. Registers are read-only. ModBus address indicated in the register map is expressed in base 1, that is, the corresponding register in PLC nomenclature would be or Example: Data packet (in hexadecimal) to read the registers from Error Com. to Zone 4 - State of slave 1: Example: CRC CRC Data packet (in hexadecimal) to read Z1-Detector2-Measure of slave 1: CRC CRC DURAN ELECTRONICA ALL rights reserved -

7 ModBus RTU Selectable communication speed: 1200, 2400, 4800, 9600, 19200, and BPS. (Data bits: 8, parity: none, Stop bits: 1). The ModBus slave number is selectable and does not correspond with the number of the connected control panel. Physical connection may be carried out with RS232 or RS485, selectable in the configuration software Only the RX, TX and GND of RS232 lines or the TX/RX+ and TX/RX- RS485 lines are used. ModBus TCP The TCP port is configurable (502 by default). IP address, sub network mask and default router address are configurable. The ModBus slave number in the TCP data pack is ignored, that is, an answer is obtained in any case. DEGD Control Panel Only the 2-RX, 3-TX, 7-RTS, 8-CTS and 5-GND of the RS232 are used. The connection cable between the control panel and the Intesis box must be null modem type. Pins 2 and 3 must be crossed between cable extremes. Pins 7 and 8 must be crossed between cable extremes. The control panel must be configured for sequential reading mode. I-manModBusDE1-vo1 7

8 6. ModBus REGISTER MAP *Add indicates ModBus register Address in base 1. Communication state Add Register description 1 Communications error Zone state Add Reg. description Add Reg. description Add Reg. description Add Reg. description 10 Zone 1 - State 20 Zone 2 - State 30 Zone 3 - State 40 Zone 4 - State 11 Zone 1 - PorgIng 21 Zone 2 - PorgIng 31 Zone 3 - PorgIng 41 Zone 4 - PorgIng 12 Zone 1 - PorgUsr 22 Zone 2 - PorgUsr 32 Zone 3 - PorgUsr 42 Zone 4 - PorgUsr 13 Zone 1 - ACFail 23 Zone 2 - ACFail 33 Zone 3 - ACFail 43 Zone 4 - ACFail 14 Zone 1 - BatFail 24 Zone 2 - BatFail 34 Zone 3 - BatFail 44 Zone 4 - BatFail 15 Zone 1 - GrpFail 25 Zone 2 - GrpFail 35 Zone 3 - GrpFail 45 Zone 4 - GrpFail Group state Add Register description 401 Z1 - Group 1 - State 402 Z1 - Group 2 - State 403 Z1 - Group 3 - State 404 Z1 - Group 4 - State 405 Z2 - Group 1 - State 406 Z2 - Group 2 - State 407 Z2 - Group 3 - State 408 Z2 - Group 4 - State 409 Z3 - Group 1 - State 410 Z3 - Group 2 - State 411 Z3 - Group 3 - State 412 Z3 - Group 4 - State 413 Z4 - Group 1 - State 414 Z4 - Group 2 - State 415 Z4 - Group 3 - State 416 Z4 - Group 4 - State DURAN ELECTRONICA ALL rights reserved -

9 Detectors: Measurings, States and Gases Add Register description Add Register description Add Register description 101 Z1 - Detector 1 - Measure 201 Z1 - Detector 1 - State 301 Z1 - Detector 1 - Gas 102 Z1 - Detector 2 - Measure 202 Z1 - Detector 2 - State 302 Z1 - Detector 2 - Gas 103 Z1 - Detector 3 - Measure 203 Z1 - Detector 3 - State 303 Z1 - Detector 3 - Gas 104 Z1 - Detector 4 - Measure 204 Z1 - Detector 4 - State 304 Z1 - Detector 4 - Gas 105 Z1 - Detector 5 - Measure 205 Z1 - Detector 5 - State 305 Z1 - Detector 5 - Gas 106 Z1 - Detector 6 - Measure 206 Z1 - Detector 6 - State 306 Z1 - Detector 6 - Gas 107 Z1 - Detector 7 - Measure 207 Z1 - Detector 7 - State 307 Z1 - Detector 7 - Gas 108 Z1 - Detector 8 - Measure 208 Z1 - Detector 8 - State 308 Z1 - Detector 8 - Gas 109 Z1 - Detector 9 - Measure 209 Z1 - Detector 9 - State 309 Z1 - Detector 9 - Gas 110 Z1 - Detector 10 - Measure 210 Z1 - Detector 10 - State 310 Z1 - Detector 10 - Gas 111 Z1 - Detector 11 - Measure 211 Z1 - Detector 11 - State 311 Z1 - Detector 11 - Gas 112 Z1 - Detector 12 - Measure 212 Z1 - Detector 12 - State 312 Z1 - Detector 12 - Gas 113 Z1 - Detector 13 - Measure 213 Z1 - Detector 13 - State 313 Z1 - Detector 13 - Gas 114 Z1 - Detector 14 - Measure 214 Z1 - Detector 14 - State 314 Z1 - Detector 14 - Gas 115 Z1 - Detector 15 - Measure 215 Z1 - Detector 15 - State 315 Z1 - Detector 15 - Gas 116 Z1 - Detector 16 - Measure 216 Z1 - Detector 16 - State 316 Z1 - Detector 16 - Gas 117 Z2 - Detector 1 - Measure 217 Z2 - Detector 1 - State 317 Z2 - Detector 1 - Gas 118 Z2 - Detector 2 - Measure 218 Z2 - Detector 2 - State 318 Z2 - Detector 2 - Gas 119 Z2 - Detector 3 - Measure 219 Z2 - Detector 3 - State 319 Z2 - Detector 3 - Gas 120 Z2 - Detector 4 - Measure 220 Z2 - Detector 4 - State 320 Z2 - Detector 4 - Gas 121 Z2 - Detector 5 - Measure 221 Z2 - Detector 5 - State 321 Z2 - Detector 5 - Gas 122 Z2 - Detector 6 - Measure 222 Z2 - Detector 6 - State 322 Z2 - Detector 6 - Gas 123 Z2 - Detector 7 - Measure 223 Z2 - Detector 7 - State 323 Z2 - Detector 7 - Gas 124 Z2 - Detector 8 - Measure 224 Z2 - Detector 8 - State 324 Z2 - Detector 8 - Gas 125 Z2 - Detector 9 - Measure 225 Z2 - Detector 9 - State 325 Z2 - Detector 9 - Gas 126 Z2 - Detector 10 - Measure 226 Z2 - Detector 10 - State 326 Z2 - Detector 10 - Gas 127 Z2 - Detector 11 - Measure 227 Z2 - Detector 11 - State 327 Z2 - Detector 11 - Gas 128 Z2 - Detector 12 - Measure 228 Z2 - Detector 12 - State 328 Z2 - Detector 12 - Gas 129 Z2 - Detector 13 - Measure 229 Z2 - Detector 13 - State 329 Z2 - Detector 13 - Gas 130 Z2 - Detector 14 - Measure 230 Z2 - Detector 14 - State 330 Z2 - Detector 14 - Gas 131 Z2 - Detector 15 - Measure 231 Z2 - Detector 15 - State 331 Z2 - Detector 15 - Gas 132 Z2 - Detector 16 - Measure 232 Z2 - Detector 16 - State 332 Z2 - Detector 16 - Gas Continued in the next page. I-manModBusDE1-vo1 9

10 P Add Register description Add Register description Add Register description 133 Z3 - Detector 1 - Measure 233 Z3 - Detector 1 - State 333 Z3 - Detector 1 - Gas 134 Z3 - Detector 2 - Measure 234 Z3 - Detector 2 - State 334 Z3 - Detector 2 - Gas 135 Z3 - Detector 3 - Measure 235 Z3 - Detector 3 - State 335 Z3 - Detector 3 - Gas 136 Z3 - Detector 4 - Measure 236 Z3 - Detector 4 - State 336 Z3 - Detector 4 - Gas 137 Z3 - Detector 5 - Measure 237 Z3 - Detector 5 - State 337 Z3 - Detector 5 - Gas 138 Z3 - Detector 6 - Measure 238 Z3 - Detector 6 - State 338 Z3 - Detector 6 - Gas 139 Z3 - Detector 7 - Measure 239 Z3 - Detector 7 - State 339 Z3 - Detector 7 - Gas 143 Z3 - Detector 8 - Measure 240 Z3 - Detector 8 - State 340 Z3 - Detector 8 - Gas 141 Z3 - Detector 9 - Measure 241 Z3 - Detector 9 - State 341 Z3 - Detector 9 - Gas 142 Z3 - Detector 10 - Measure 242 Z3 - Detector 10 - State 342 Z3 - Detector 10 - Gas 143 Z3 - Detector 11 - Measure 243 Z3 - Detector 11 - State 343 Z3 - Detector 11 - Gas 144 Z3 - Detector 12 - Measure 244 Z3 - Detector 12 - State 344 Z3 - Detector 12 - Gas 145 Z3 - Detector 13 - Measure 245 Z3 - Detector 13 - State 345 Z3 - Detector 13 - Gas 146 Z3 - Detector 14 - Measure 246 Z3 - Detector 14 - State 346 Z3 - Detector 14 - Gas 147 Z3 - Detector 15 - Measure 247 Z3 - Detector 15 - State 347 Z3 - Detector 15 - Gas 148 Z3 - Detector 16 - Measure 248 Z3 - Detector 16 - State 348 Z3 - Detector 16 - Gas 149 Z4 - Detector 1 - Measure 249 Z4 - Detector 1 - State 349 Z4 - Detector 1 - Gas 150 Z4 - Detector 2 - Measure 250 Z4 - Detector 2 - State 350 Z4 - Detector 2 - Gas 151 Z4 - Detector 3 - Measure 251 Z4 - Detector 3 - State 351 Z4 - Detector 3 - Gas 152 Z4 - Detector 4 - Measure 252 Z4 - Detector 4 - State 352 Z4 - Detector 4 - Gas 153 Z4 - Detector 5 - Measure 253 Z4 - Detector 5 - State 353 Z4 - Detector 5 - Gas 154 Z4 - Detector 6 - Measure 254 Z4 - Detector 6 - State 354 Z4 - Detector 6 - Gas 155 Z4 - Detector 7 - Measure 255 Z4 - Detector 7 - State 355 Z4 - Detector 7 - Gas 156 Z4 - Detector 8 - Measure 256 Z4 - Detector 8 - State 356 Z4 - Detector 8 - Gas 157 Z4 - Detector 9 - Measure 257 Z4 - Detector 9 - State 357 Z4 - Detector 9 - Gas 158 Z4 - Detector 10 - Measure 258 Z4 - Detector 10 - State 358 Z4 - Detector 10 - Gas 159 Z4 - Detector 11 - Measure 259 Z4 - Detector 11 - State 359 Z4 - Detector 11 - Gas 160 Z4 - Detector 12 - Measure 260 Z4 - Detector 12 - State 360 Z4 - Detector 12 - Gas 161 Z4 - Detector 13 - Measure 261 Z4 - Detector 13 - State 361 Z4 - Detector 13 - Gas 162 Z4 - Detector 14 - Measure 262 Z4 - Detector 14 - State 362 Z4 - Detector 14 - Gas 163 Z4 - Detector 15 - Measure 263 Z4 - Detector 15 - State 363 Z4 - Detector 15 - Gas 164 Z4 - Detector 16 - Measure 264 Z4 - Detector 16 - State 364 Z4 - Detector 16 - Gas DURAN ELECTRONICA ALL rights reserved -

11 7. Description of ModBus register contents Communications error Signals the state of communications with gas detection control panel. If it is on 1 it indicates a communications error and all other registers maintain the last recorded value. If it is on 1, it is a critical error because information is not being read from the control panel. Values Description 0 OK 1 There is no answer from the control panel Zone - State Signals state of Detection zone. Correct state value is 2-ON. Values Description 0 Does not exist 1 Off 2 On Zone - Proglng Signals state of Detection zone. Correct state value is 0-Normal. Values Description 0 Normal 1 In Enginner programming mode Zone - ProgUsr Signals state of Detection zone. In User programming mode. Values Description 0 Normal 1 In User programming mode I-manModBusDE1-vo1 11

12 p Zone - ACFail Signals state of Detection zone. Correct state value is 0-Normal. Values Description 0 Normal 1 AC net failure Zone - BatFail Signals state of Detection zone. Correct state value is 0-Normal. Values Description 0 Normal 1 Battery failure Zone - GrpFail Signals state of Detection zone. Correct state value is 0-Normal. Values Description 0 Normal 1 Group failure Group - State Signals state of actuation group. Values Description 0 Does not exist 1 Stop 2 Auto 3 Manual 4 Vent1 5 Vent2 6 Goff 7 V CI 255 Unknown DURAN ELECTRONICA ALL rights reserved -

13 Detector - Measuring It is the analogical measuring from the gas detector. *In the case of NO2 and O2 gases the data is presented multiplied by a hundred, so as to be able to recover the decimal part. *If detector does not exist, register will show 0 value. Values Description 398 Maximum value for CO (ppm) 19.9 Maximum value for NO2 (ppm) Maximum value for O2 (%) Maximum value for CO2 (ppm) 99 Maximum value for EXP (%) 99 Maximum value for NH3 (ppm) 199 Maximum value for all others (ppm) Detector - State It is the detector state. *If a detector is in state 9 -Saturation- the Measuring register will indicate the bottom of scale value. Values Description 0 Does not exit 1 Normal 2 Vent1 3 Vent2 4 Alarm 5 Error 6 Detector failure 7 Warning 8 Prealarm 9 Saturation Detector - Gas Identifies the Gas being measured by the detector. *If there is no detector, the register shows value 0. *The way of knowing if a detector has been connected to the control panel, is to check that the register has value different from 0. Valores Description 0 Not installed or configured in the Module line 1 CO 2 CO2 3 NO 4 NO2 5 H2S 6 SO2 7 CI2 8 HCI 9 O2 10 EXP (explosive gas) 11 NH3 I-manModBusDE1-vo1 13

14 8. Device dimensions Recommended necessary space for installation in cabinet (wall mounting or DIN rail), taking into account sufficient space for connections: DURAN ELECTRONICA ALL rights reserved -

15 9. Equipment configuration To configure ModBus parameters, LinkBoxMB software must be used. This software is available for free. Quick guide: 1) Select the Demo DEGD project. 2) Select the PC COM to connect to the equipment. 3) Select the IntesisBox Configuration menu, carry out desired ModBus configuration and save. 4) Connect the PC COM to the device console port with the supplied cable. 5) Activate the OffLine box which, when the connection happens, will turn to OnLine in green. 6) Press the Send File button. Once these operations have been carried out, equipment will have been configured. 9.1 Project selection Select Demo DEGD in the projects window. You can generate new projects, if you wish, for each different installation where you use the equipment. 9.1 Console port selection. Configuration and Connection Select COM serial port of the PC you will use to Connect to the equipment I-manModBusDE1-vo1 15

16 9.3 Selection of ModBus configuration. INTESISBOX configuration Select desired ModBus configuration from the available options and Accept 9.4 Download configuration into equipment Activate the OffLine box which, when the connection happens will turn to OnLine green, and press the Send File button DURAN ELECTRONICA ALL rights reserved -

17 9.5 View signals From the view - signals menu this window opens, in which you can see all ModBus register values. For one first update of the data press the Update button and, once you are Online, the data will update automatically. This window is very useful to check on equipment state. I-manModBusDE1-vo1 17

18 9.6 View DEGD Bus From the View - Bus - DEGD menu this window opens, where you can see communications with the gas detection control panel. In normal conditions there should be constant activity. 9.7 View ModBus Bus From the view - Bus - ModBus this window opens, where you can see the ModBus communications. There will only be activity when there is a master ModBus checking the device DURAN ELECTRONICA ALL rights reserved -

19 10. Technical characteristics Box Colour Grey. Ral Power supply Mounting Detection Control Panel Port ModBus RTU Port PC Type plastic (UL 94 V-0). Measures: 107mm x 105mm x 58mm. 9 to 30VDC +/-10% 1,4W. 24VAC +/-10% 1,4VA. Connector to power supply: 2-terminal plug in wire connector. Table. Wall mounted. DIN EN60715 TH35 rail. 1 x Serie RS232. Connector: DB9 male (DTE) 1 x Serie RS232. Connector: DB9 male (DTE) 1 x Serie RS485. Connector: 2-terminal plug in wire connector (+/-) ModBus TCP Port 1 x Ethernet 10BT. Connector RJ45. 1 LED indicators Console Ports 1 x Power supply. 2 x ModBus RTU (Tx, Rx) port activity. 2 x Ethernet, ModBus TCP (ACT, LNK) activity. 1 RS232. Connector DB9 Female (DCE). Configuration Through console port. 2 Firmware Working temperature range Working humidity range Protection grade RoHS conformity Certifications Updated through console port. 0ºC to +70ºC. 5% to 95%, no condensation. IP20 (in accordance to IEC60529). Complies with RoHS directive (2002/95/CE). CE 1 Only available in the model supporting TCP. 2 Along with the device, a standard 1.8 meter DB9male - DB9female cable for direct connection to a PC serial port is supplied for configuration and monitoring of the device. I-manModBusDE1-vo1 19

20 2010 DURAN ELECTRONICA ALL rights reserved -

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems Honeywell Life Safety Iberia C/Pau Vila 15-19; 08911 Badalona Barcelona T. 902 03 05 45; Internacional:+34932424236 www.honeywelllifesafety.es infohlsiberia@honeywell.com ibox Modbus Server Gateway for

More information

IntesisBox BACnet/IP Server - Notifier ID3000 series

IntesisBox BACnet/IP Server - Notifier ID3000 series IntesisBox Server - Notifier ID3000 series Gateway for integration of Notifier ID3000, ID3002, ID50 and ID60 fire panels into enabled control systems. Integrate your Notifier fire panels into your BACnet

More information

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

LINEAR HEAT DETECTION CABLE DURÁN-SAFE LINEAR HEAT DETECTION CABLE DURÁN-SAFE Installation & User Manual 2018 DURAN ELECTRONICA S.L. - All rights reserved www.duranelectronica.com I-manSAFECABLE-v05 TABLE OF CONTENTS Pages 1. INTRODUCTION...

More information

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays

More information

User manual. KNXpar. version

User manual. KNXpar. version User manual version 1.3 KNXpar Management alarm control panels Paradox from KNX bus Powered from KNX bus Communication indication on KNX and with Paradox control panel DIN rail mount (1 module) Adjustable

More information

User and Installation manual

User and Installation manual Toxic, explosive and oxygen gas detection control panel User and Installation manual FS82426 2018 DURAN ELECTRONICA S.L. - All rights reserved www.duranelectronica.com RANGE OF COMPATIBLE PRODUCTS Remote

More information

P2267 NETWORK INTERFACE

P2267 NETWORK INTERFACE P2267 NETWORK INTERFACE USER MANUAL FOR OPERATING SYSTEMS: 22031-03 23636-01 October 2009 Associated Controls (Australia) Pty. Limited 2-4 Norfolk Road Greenacre, NSW, 2190. PH +61 2 9642 4922, FAX +61

More information

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head 4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head NET DRAFT version 2.1-2008 Pag. 1 4-20mA Cyber - DRAFT version 2.1-2008 Pag.

More information

21-light Remote Annunciator. Owner s Manual

21-light Remote Annunciator. Owner s Manual 21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With

More information

Alarm module for leak detection with webserver

Alarm module for leak detection with webserver This instruction document consists of 2 parts : one part about the assembly of the components and one part about configuration and starting-up of the system. The assembly is done by the qualified installer

More information

RS485 MODBUS Module 8AI

RS485 MODBUS Module 8AI Version 1.4 15/04/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

Gas Controller Module GC-06

Gas Controller Module GC-06 Page 1 Oct. 2015/2 Measuring, warning and controlling module for toxic, combustible and refrigerant gases and vapours. The gas controller series GC-06 is designed in accordance with the standard EN 50545-1.

More information

MiNi Server environment MoNitoriNg SySteM

MiNi Server environment MoNitoriNg SySteM enviromux-mini with enviromux-t-3 temperature Sensor Features & Applications Monitors threats: temperature Humidity Water Leakage intrusion The ENVIROMUX Mini Server Environment Monitoring System monitors

More information

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1 NGC-40 Bridge Overview Raychem-AR-H58862-NGC40BridgeOV-EN-1805 nvent.com 1 Table of Contents 1. NGC-40 Overview... 9 1.1 Example NGC-40 System... 10 2. Legal stuff... 11 3. Protocols... 12 3.1 Data es...

More information

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS.  A4741 / Rev.1 DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS User Manual and Menu Map A4741 / Rev.1 www.entes.com.tr ATTENTION -Disconnect all power before connecting the device. -Don t remove

More information

Added password for IP setup page : Password must be in IP format!

Added password for IP setup page : Password must be in IP format! NETWORK POWER MONITOR Release : 21 August 2014 Hardware Version : Version 7 Firmware version 1.00 PC Application Software : Version (latest)...2 Added password for IP setup page : Password must be in IP

More information

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE General Description This guide provides a summary for installing and configuring the Centaur TM Cube Slave Alarm Signalling Equipment

More information

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features. CONsOlIDATOR 4 & 8 MulTI- C h ANNEl CONTROllERs ConsoliDator 4 Model PD940 ConsoliDator 4 Features Four 4-20 Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Two 4-20 Outputs Common Features Four Pulse

More information

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual.

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual. Page : 1 of 17. ELAUSYS EVO-KNX KNX Interface for Paradox alarm system User Manual Document history Version. Date Author Comment 1.00 14-AUG-2017 NDE First issue Page : 2 of 17 TABLE OF CONTENT 1. INTRODUCTION

More information

Fire and Gas Monitoring Panel ST7-HV

Fire and Gas Monitoring Panel ST7-HV Fire and Gas Monitoring Panel ST7-HV INTRODUCTION TO THE ST7-HV SYSTEM The ST7-HV system is a programmable PLC suitable for safety and security installations with a high technological and economic content

More information

User manual. KNXgal. version

User manual. KNXgal. version User manual version 1.3 gal Management alarm control panels Galaxy from bus powered from bus Communication indication on and with Galaxy control panel DIN rail mount (1 modul) Adjustable address on with

More information

ECL Comfort 310 controller, Remote Control Units ECA 30 / 31 and Application keys

ECL Comfort 310 controller, Remote Control Units ECA 30 / 31 and Application keys ECL Comfort 310 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark Description ECL Comfort 310 controller series ECL 310 The ECL Comfort 310 is an electronic weather

More information

mti085 Temperature Interface

mti085 Temperature Interface Temperature Interface 1-WIRE INTRINSICALLY SAFE mti085 mti085 Temperature Interface Document No. 10432 Revision H July 2007 2001-2006 CMC Industrial Electronics Ltd. This page intentionally left blank

More information

600 Range Dialer Installation Manual. Version 1.0

600 Range Dialer Installation Manual. Version 1.0 600 Range Dialer Installation Manual Version 1.0 The information contained is supplied without liability for any errors or omissions. No part may be reproduced or used except as authorised by contract

More information

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The nvent RAYCHEM NGC-40 is a multipoint

More information

ACTIVE INFRARED BARRIER

ACTIVE INFRARED BARRIER Although PROTECH provides high security indoor intrusion sensors for the military and government markets, our specialty is outdoor protection. Since we first introduced our PIRAMID outdoor dual technology

More information

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X X testregistrierung Type Web server, also for mobile devices Zone modules Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X-AIRCONTROL zone

More information

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1- DPR-45 User Manual V-2.0 (2..206) DPR-45 TEMPERATURE PROTECTION RELAY PT00 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT 9-50VDC SUPPLY DESCRIPTION DPR-45 is a precision unit designed for the temperature

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

DTSX200 Communications(Modbus) Guide

DTSX200 Communications(Modbus) Guide User s Manual DTSX200 Communications(Modbus) Guide 4th Edition Blank Page < Introduction > i Introduction About this Manual Thank you for purchasing the DTSX200 Distributed Temperature Sensor. This document

More information

ME 3011C / Alarm Indication / Quick Reference Guide

ME 3011C / Alarm Indication / Quick Reference Guide Tables of Contents Page Application 1 Features 1 Important Safety Information! 2 Note to this Guide 2 Further Information 2 Device Variants 2 General Functions 3 Annunciator Sequences - ISA 18.1 3 Plan

More information

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014) AIS750 Series Alarm Annunciator User Manual (Ver 23 / JUNE 2014) 3-350 John Street, Thornhill, tario L3T 5W6 Phone: 289 597 APEX (2739) Fax: 289 597 2200 Toll Free: 1 866 776 2943 Email: mail@annunciatorca

More information

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification February 11, 2019 Master Panel Product Description The Master Panel shall provide lead/lag control and time based, automatic rotation of up to eight (8) boilers, when used in conjunction with LMV3 or LMV5

More information

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option SM3000 Videographic Recorder User Guide (RTU) Communications Option ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control, flow

More information

FCD-wire Contents. List of Figures

FCD-wire Contents. List of Figures FCD-wire Contents FCD-X21 Configuration 1 Introduction... 1 2 Opening the FCD Application... 1 3 FCD Window... 2 4 FCD LEDs... 3 5 Configuration Operations... 4 FCD Info...4 FCD System Info...5 FCD Interface

More information

Series Digital Controller Instruction Sheet

Series Digital Controller Instruction Sheet 216/3/11 Series Digital Controller Instruction Sheet Thank you very much for purchasing DELTA DTC Series Temperature Controller. Please read this instruction sheet before using your DTC series to ensure

More information

Products no longer available

Products no longer available Technical data sheet MONICO-.. Turnkey automation station MONICO-.. Forms an efficient fire protection system together with the motorisation sets BF(G)24MP Completely wired controller in matching control

More information

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The Raychem NGC-40 is a multipoint electronic

More information

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Process & TeMPerATUre UniversAl input DigiTAl MeTers Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min

More information

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system. Page : 1 of 17. ELAUSYS JA-KNX KNX Interface for Jablotron alarm system User Manual Document history Version. Date Author Comment 1.00 24-JUN-2017 NDE First issue 1.01 14-NOV-2017 NDE Support for user

More information

Alarm Panel [ PRELIMINARY HARDWARE MANUAL ] USER MANUAL. v1.0a. May 7, 2008 D-OC-UM

Alarm Panel [ PRELIMINARY HARDWARE MANUAL ] USER MANUAL. v1.0a. May 7, 2008 D-OC-UM Alarm Panel USER MANUAL [ PRELIMINARY HARDWARE MANUAL ] Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. May 7, 2008 D-OC-UM085.07010 v1.0a Revision History April 28, 2008 May

More information

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min

More information

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL ap15_2manual04/22/13 Page 1 4/22/2013 1 Serial Number : Option: OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL Micro Seven, Inc. 1095-K N.E. 25th Hillsboro, OR 97124 U.S.A. phone: 503-693-6982

More information

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor

More information

FST DFS Notifier Onyx 640

FST DFS Notifier Onyx 640 1 DESCRIPTION The NFS-640 Serial driver allows the FieldServer to record data from Notifier Onyx Series NFS-640, NFS2-640 and NFS-320 Fire Panels over RS-232. The FieldServer primarily acts as a Passive

More information

Danfoss gas detection unit Type GD Heavy Duty

Danfoss gas detection unit Type GD Heavy Duty Data sheet Danfoss gas detection unit Type GD Heavy Duty The Heavy Duty gas detection units are used for monitoring and warning of hazardous Ammonia gas concentrations. They are intended for ATEX/ IECEx

More information

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel from hazardous gases in

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Control Systems Transmitters Sensors Accessories Wall, 19 Rack or Panel Mounting Units 110/230V 50/60Hz AC operation 250 Addressable devices as: Relays, 4-20 Inputs or Gas Detectors

More information

FIRERAY 5000 range USER GUIDE

FIRERAY 5000 range USER GUIDE FIRERAY 5000 range USER GUIDE 0044-003-04 IMPORTANT PLEASE NOTE: The beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal.

More information

Instruction Manual Model Backup Switch, 1 for 8

Instruction Manual Model Backup Switch, 1 for 8 Instruction Manual Model 2582-282 Backup Switch, 1 for 8 December 2011, Rev. 0 MODEL 2582 SWITCH CROSS TECHNOLOGIES INC. SWITCH ALARM PSA PSB ALARM OFFLINE ONLINE UNIT STATUS 1 2 3 4 5 6 7 8 BU PROT MODE

More information

Multi-Gas-Controller MGC2

Multi-Gas-Controller MGC2 Page 1 Aug. 2018 Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology for continuous monitoring of the ambient air to detect toxic and combustible gases, refrigerants

More information

Gas Detection System TOX ALARM DG2000-Garage

Gas Detection System TOX ALARM DG2000-Garage Gas Detection System TOX ALARM DG2000-Garage Gas Detection System 32 independent programmable channels 2 programmable alarm levels for each gas = up to 6 for each channel LCD alphanumeric display of gas

More information

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick CAN OBD READER REFERENCE DESIGN KIT USER GUIDE 1. Standard ToolStick Handling Recommendations The ToolStick Base Adapter and daughter cards are distributed without any protective plastics. To prevent damage

More information

Med Touch Master Alarm

Med Touch Master Alarm Submittal Data Sheet Features The Powerex Med Touch Master Alarm Panel monitors and displays normal and alarm conditions from up to 128 remote medical gas source signals and provides alarm conditions as

More information

Installation Manual GalaXy G2 / G3 / GD. o Settings GalaXy o Linking with iprotect o Keymap

Installation Manual GalaXy G2 / G3 / GD. o Settings GalaXy o Linking with iprotect o Keymap Installation Manual GalaXy G2 / G3 / GD o Settings GalaXy o Linking with iprotect o Keymap Publication July 2013, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, The Netherlands www.keyprocessor.com

More information

PowerLogic ION Setup Meter Configuration Software Configuration Guide

PowerLogic ION Setup Meter Configuration Software Configuration Guide PowerLogic ION Setup Meter Configuration Software Configuration Guide 70002-0293-03 12/2010 Conventions Used in this Manual This section describes the symbols and terminology used in this guide. Symbols

More information

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer Installation and interface must be performed by a qualified controls technician. IMPORTANT: THIS MANUAL CONTAINS INFORMATION REQUIRED FOR INSTALLATION, INTERFACE AND CONFIGURATION OF THIS EQUIPMENT. READ

More information

Industrial Grade Gas Detection Detecting The Difference

Industrial Grade Gas Detection Detecting The Difference detcon inc. Industrial Grade Gas Detection Detecting The Difference PO Box 8067 The Woodlands, TX 77387 888-367-4286 (toll free) 713-559-9200 281-292-2860 (fax) sales@detcon.com Catalog #CB-0409 www.detcon.com

More information

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Tel: +44 (0)8 9388 Email: info@ Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel

More information

Installation Manual Tracker 221

Installation Manual Tracker 221 Installation Manual Tracker 221 KSR KUEBLER AG Im Kohlstatterfeld 17 D-69439 Zwingenberg / Germany www.ksr-kuebler.com Contents About this Installation Manual...4 Description Tracker 220-series...4 Installing

More information

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark Description ECL Comfort 210 controller series ECL 210 The ECL Comfort 210 is an electronic weather

More information

HRX Technical Manual. Version 1.2

HRX Technical Manual. Version 1.2 HRX 5000 Technical Manual Version 1.2 Contents: Specification...2 Connectors...5 RS-485 Network Connectors (J6 and J7)...5 RS-232 to Printer (J19)...6 RS-232 to PC (J8)...7 TCP/IP...8 Power (J21)...9 Fire

More information

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12 AUTOMATION P R O D U C T S GROUP, INC. Operator s Manual RST-5000 Series Web Enabled Input Module Rev. A2, 1/12 Tel: 1/888/525-7300 Fax: 1/435/753-7490 www.apgsensors.com E-mail: sales@apgsensors.com RST-5000

More information

DMFPM-2R MULTIFUNCTIONAL

DMFPM-2R MULTIFUNCTIONAL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Wed : www.saenchotesei.com WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 920 - Wall, 19 Rack or Panel Mounting Units - 110/230V 50/60Hz AC operation - 250 Addressable

More information

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable. ATSTORM v2 ATSTORM v2 is a storm detector that measures the environmental electric field. It is fully automatic, without mobile parts, robust and highly reliable The storm detector ATSTORM v2 basic configuration

More information

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

Rig Protector. Multipoint Critical Gas Detection and Monitoring System Rig Protector Multipoint Critical Gas Detection and Monitoring System Rig Protection Device Protecting Personnel from Hazardous Gases RC Systems has engineered and manufactured industrial electronic products

More information

RSMFM-2R MULTIFUNCTIONAL

RSMFM-2R MULTIFUNCTIONAL MULTIFUNCTIONAL ROOM Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL

More information

Products and performance

Products and performance Products and performance February 26, 2016 GfG Instrumentation overview of fixed system products Slide 1 GfG Instrumentation, Inc. 1194 Oak Valley Drive, Suite 20, Ann Arbor, Michigan 48108 Toll free (USA

More information

Temperature Controllers

Temperature Controllers Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65

More information

CBI-064. User Manual. Caddx to KNX-BUS Interface

CBI-064. User Manual. Caddx to KNX-BUS Interface CBI-064 Caddx to KNX-BUS Interface User Manual GDS Intelligence in Buildings El. Venizelou 116 Nea Erithrea 14671 Tel: +30 2108071288 Email: info@gds.com.gr Web: gds.com.gr Contents 1 Device Description...

More information

Danfoss gas detection Controller unit

Danfoss gas detection Controller unit Data sheet Danfoss gas detection Controller unit The gas detection Controller Unit is used for a centralized monitoring and warning of hazardous gas concentrations. The input signals for the controller

More information

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014 Solar Charge controller with Ethernet Release : 19 June 2014 Hardware Version : Version 1 Firmware version 1 PC Application Software : Version 1.0.0.0 Hardware Description : The Solar Smart regulator was

More information

Compod. Instruction Manual IM-COMPOD Revision: F, December 2015

Compod. Instruction Manual IM-COMPOD Revision: F, December 2015 Compod Programmable Control Module For 100 Series Digital Mass Flow Meters & Controllers Instruction Manual IM-COMPOD Revision: F, December 2015 CORPORATE HEADQUARTERS 5 Harris Court, Building L, Monterey,

More information

Advisor Advanced Mobile Application User Manual

Advisor Advanced Mobile Application User Manual Advisor Advanced Mobile Application User Manual Content Warnings and Disclaimers 2 Advanced Mobile 2 Contact information 2 Description 2 Screen navigation 4 Gestures 4 Menu 4 Help navigation 4 Login 5

More information

Application Manual LT-6617 Rev. 1 July 2017

Application Manual LT-6617 Rev. 1 July 2017 Application Manual LT-6617 Rev. 1 July 2017 Table of Contents 1.0 Frequently Asked Questions 4 2.0 OpenBAS Wiring Guidelines 6 3.0 Wiring 9 4.0 Glossary 11 3 1.0 Frequently Asked Questions 1.1 What is

More information

F Technical Bulletin SC 370 SMART Modbus Interface

F Technical Bulletin SC 370 SMART Modbus Interface F7904502 Document Revision History Document Versiosion Modbus Map Ver- Date Author Notes 1 10 9/26/17 JGG Document Created Flash Technology, 332 Nichol Mill Lane, Franklin, TN 37067 www.flashtechnology.com

More information

User s Guide CN616A. Universal 6 Channel ¼ DIN Process Controller. Shop online at omega.com

User s Guide CN616A. Universal 6 Channel ¼ DIN Process Controller. Shop online at omega.com TM User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info CN616A Universal 6 Channel ¼ DIN Process Controller omega.com info@omega.com U.S.A. Headquarters:

More information

CLEANROOM MONITOR CR3A Network - Installation Instructions

CLEANROOM MONITOR CR3A Network - Installation Instructions CLEANROOM MONITOR CR3A Network - Installation Instructions INTRODUCTION The CR3 Series Cleanroom Monitor, was developed specifically to allow for monitoring of confined spaces with accuracy and reliability.

More information

DAP III Zone Master User s Guide

DAP III Zone Master User s Guide DAP III Zone Master User s Guide Data Aire, Inc. 230 West BlueRidge Avenue Orange, California 92865 Document Number 600-000-788 March 2010 Revision 1.0 Document # 600-000-788 1 Overview The Data Aire DAP

More information

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING Manual Contents Introduction...3 Valve compatibility...3 Features...3 Application examples...3 Ordering...3 Operating the EKC 347...4-5

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL INSTALLATION AND OPERATING MANUAL Spectron Gas Control Systems GmbH Fritz-Klatte-Str. 8 65933 Frankfurt Germany Tel.: +49 69 38016-0 Fax: +49 69 38016-200 info@spectron.de www.spectron.de is a unit that

More information

Metasys Integrator Compu-Aire Application

Metasys Integrator Compu-Aire Application Metasys Connectivity Technical Manual 629.5 Metasys Integrator Section Application Note Issue Date 0496 APPLICATION NOTE Metasys Integrator Compu-Aire Application lntroduction Page 3 Application Details

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or

More information

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008 TCD Telemetry Communications Device Installation Guide Interface for the Emizon managed network Issue 1: February 2008 This guide sets out a simple check list together with a step-by-step guide to the

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2 Features Integrated (built-in NO2 sensor / detector (Electro chemical sensor type Measuring ranges 0-10 ppm, 0-20 ppm or 0-30 ppm LCD display to show actual in ppm Status LED indication Normal operation

More information

Series Temperature Controller Instruction Sheet

Series Temperature Controller Instruction Sheet Series Temperature Controller Instruction Sheet Thank you very much for purchasing DELTA A Series. Please read this instruction sheet before using your A series to ensure proper operation and please keep

More information

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0 IRIS Touch Quick Installation & Maintenance Guide Version 1.0 Page 2 of 16 IRIS Touch Quick Installation & Maintenance Guide Version 1.0 Contents 1. Introduction... 4 2. Product Features... 4 3. Package

More information

INSTALLATION INSTRUCTIONS and BASIC SYSTEM CONFIGURATION

INSTALLATION INSTRUCTIONS and BASIC SYSTEM CONFIGURATION INSTALLATION INSTRUCTIONS and BASIC SYSTEM CONFIGURATION 200091-A 2/23 Contents 1. Warnings & Notes... 3 2. Installation of system to electrical cabinet or modular box... 3 3. Powering the system... 7

More information

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160 All-In-One Wireless Security System V3.2 Programming Guide Model # MG6130 / MG6160 We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com

More information

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no ) Product definition KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no 2343 00) Art. no 2343 00 Page 1 of 22 Product definition Table of contents 1 Product definition... 3 1.1 Product catalogue...

More information

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6 Digital Gas Transmitters with Auxiliary s & Control Specifications subject to change without notice. USA 181011 Page 1 of 5 DESCRIPTION Digital RS-485 communicating, addressable toxic and combustible gas

More information

Tri-Tech Medical Inc.

Tri-Tech Medical Inc. Submittal Data Sheet Project Information Project Number Approval Features The Master Alarm Panel conversion kits are designed to upgrade or retro-fit existing panels produced by several major brands. The

More information

1600 Gas Controller. User s Manual. Industrial Scientific Corporation. Version 3.2 September 1, 2006

1600 Gas Controller. User s Manual. Industrial Scientific Corporation. Version 3.2 September 1, 2006 1600 Gas Controller User s Manual Version 3.2 September 1, 2006 Industrial Scientific Corporation 1 INTRODUCTION... 1 1.1 GENERAL OPERATION... 1 1.1.1 Power Up... 1 1.1.2 Viewing Sensors... 2 1.1.3 Acknowledging

More information

CTT8 TEMPERATURE MONITOR DEVICE

CTT8 TEMPERATURE MONITOR DEVICE INSTRUCTION MANUAL IM302-U v2.3 CTT8 TEMPERATURE MONITOR DEVICE GENERALITY The device of control temperatures CTT8 is used in the control of electric machine, transformer, motor, etc. where it s possible

More information

Toxic and Explosive Smart Gas Monitor PN / Installation and User Manual

Toxic and Explosive Smart Gas Monitor PN / Installation and User Manual Toxic and Explosive Smart Gas Monitor PN 151022/151023 Installation and User Manual Quest Controls, Inc. 208 9 th Street Dr. West Palmetto, FL 34221 www.questcontrols.com Phone: (941) 729-4799 Fax: (941)

More information

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS SCADA INTERFACE INSTRUCTIONS - OPTION 21S - FOR A36D/TPSD SYSTEMS with option 500 and 550. A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE OPTION 21S INSTRUCTIONS This manual is valid for A36D/TPSD Chargers

More information

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen PolyGard Single Point Controller SPC-X3-XX for Toxic Gases and Oxygen DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor and

More information

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software La Marche Manufacturing Company www.lamarchemfg.com DNP 3.0 Serial (RS232/RS485) and Ethernet (TCP/IP) SCADA Interface for A36D & TPSD Chargers with S2A-341S and S2A-383S communication cards. Option 21P,

More information