Zurn Fire Protection - Overview. December 2018

Size: px
Start display at page:

Download "Zurn Fire Protection - Overview. December 2018"

Transcription

1 Zurn Fire Protection - Overview December 2018

2 agenda what you ll learn 01 value proposition how it works 04 design & specify 05 summary 06 resources page 02

3 FIRE PROTECTION SOLUTIONS The perfect safety plan requires having the necessary fire protection solutions in place. Our technologically advanced backflow prevention products with USC certified flow curves, automatic control valves, and fire valves continually deliver consistent performance results; exceed all fire sprinkler code requirements; feature easier installation; and simplify repair and maintenance, resulting in lower cost of ownership and priceless peace of mind. Zurn Headquarters Milwaukee, WI fire protection system

4 WE RE SOLVING SMARTER Zurn, a trusted and reliable fire protection leader, is solving smarter with a comprehensive line of fire protection solutions, providing contractors and engineers a single industry expert simplifying your sourcing needs for a fire system. Zurn Fire Protection Solutions include trusted products to help you get your fire sprinkler project done right and ahead of schedule.

5 voice of customer industries contractor I need products that are easy and cost-effective to install, that are assembled and packaged in a manner that streamlines labor. engineer I need products that are durable and cost-effective and provide the lowest life-cycle costs for my clients. distributor I need products that are readily available, meet the project standards and are provided by a trusted, reliable brand. Healthcare Retail Food Service Hospitality Restaurants Institutional/Education Government page 05

6 overview fire protection system types Wet Pipe System is filled with water. During a fire, heat causes the sprinkler head element to burst, discharging water. Each sprinkler head is independent and reacts quickly to heat. Simplest and most common system design used in commercial applications Dry Pipe When wet pipe systems are at risk of freezing, dry pipe systems are recommended. Pipes are filled with pressurized air or nitrogen. When a sprinkler head is activated, air will be released, triggering the opening of a master valve which introduces water to the system Deluge The system is dry. The sprinkler heads do not contain the heat element, and are open. Once the master valve is triggered to open, water is introduced to the system and all the heads discharge water at once. The objective is to completely blanket the area with water Pre-action A dry system that is triggered by a fire or smoke detector. These systems are used in critical applications such as high value inventory or irreplaceable items are protected Foam For buildings that handle highly hazardous components and flammable liquids such as aircraft hangers, a foam blanket consisting of foam and water is discharged to completely envelop and extinguish the fire

7 Zurn fire protection components standpipe systems In North America, a standpipe is a type of rigid water piping which is built into multi-story buildings in a vertical position or bridges in a horizontal position, to which fire hoses can be connected, allowing manual application of water to the fire. Within the context of a building or bridge, a standpipe serves the same purpose as a fire hydrant. Wet standpipe systems (70% of the market) A "wet" standpipe is filled with water and is pressurized at all times. In contrast to dry standpipes, which can be used only by firefighters, wet standpipes can be used by building occupants. Wet standpipes generally already come with hoses so that building occupants may fight fires quickly. This type of standpipe may also be installed horizontally on bridges. Manual wet standpipe Must be supplemented by a fire department pumper truck via the fire department connection to achieve the necessary flow rates and pressure requirements at the most remote standpipe. Automatic wet standpipe Does NOT need a supplemental water supply but can be properly operated with the water supply and equipment it was originally designed, typically with a fire pump to boost the city water supply pressure and achieve the required pressures at the most remote standpipe.

8 Zurn fire protection product categories

9 Zurn fire protection components wet standpipe systems 5. Check Valves (Model F210) Retains water in the sprinkler system so that the Fire Department Connection can be utilized 4. Backflow Prevention (350ASTDABG shown) (DC, DCDA, RP, RPDA multiple options and configurations) Ensure water flows forward only, avoiding cross-contamination to your potable water supply 3. Automatic Control Valves (Model ZW209FP) Ensure steady downstream pressure, controlling inlet pressure, used as a system or floor control valve 2. Shut-Off Valves (Models 48OSY (shown), 48OSYG, 48OSYGXF, F48OS&YF, 48PI, 49, F49, F49BR, F49BRG) Full flow way valve serving as a systems control or floor control 1. Building Risers (Model Wilkins Building Riser - WBR) Deliver water to hose systems and sprinkler systems from the outside water supply line, typically from under the building Disclaimer for illustrative purposes only, not a typical system!

10 Zurn fire protection components wet standpipe systems Butterfly Valve Disclaimer for illustrative purposes only, not a typical system! 13. Fire Valves Pressure Reducing Valves (Z3000, Z3005, Z3004, Z2100, Z2105, ZW4100, ZW4104, ZW4000, ZW4004) Provides floor control (with check feature), used to isolate the sprinkler run so maintenance can be performed 10. Commercial Riser (Model FEZR-TD) Combines water flow detector, test and drain and pressure gauge to monitor systems pressure 12. Fire Valves Hose Valves/ Restricting Hose Valves (Models F100, F105) Standpipe valve listed for use as a fire department outlet connection (or fire hose rack assembly) 11. Test and Drain Valves (Model FTD) Provide for required water flow testing and draining of a sprinkler system with one valve 9. Riser Checks (Model F210R and optional Check Trim Kit) zone water check to prevent system reversal of flow; as required by systems including sprinkler standpipe systems and fire department connections 8. Butterfly Valve (Model F49) Short, light weight valve used as a system shutoff or floor control 7. Fire Department Connections (Model FDC2) Provide a means for firefighters to connect hose lines to a fire sprinkler system to supplement the domestic water supply, if needed 6. Fittings and Couplings (Model F210) Provide structure to the system, connecting pipe, changing pipe direction and reducing pipe sizes

11 high rise fire system component placement ZW4104 Pressure-Tru Pressure Reducing Fire Sprinkler Control Valve regulates pressure under both flow and no-flow conditions with Z3000 Pressure-Tru Pressure Reducing Fire Hose Valve a standpipe valve for individual hose stations to regulate pressure under both flow and non-flow conditions ZW4004 Pressure-Tru Pressure Reducing Fire Sprinkler Control Valve a factory set standpipe valve that regulates pressure under both flow and no-flow conditions Z3000 Pressure-Tru Pressure Reducing Fire Hose Valve a standpipe valve for individual hose station systems to regulate pressure under both flow and no-flow conditions 350AST Double Check Backflow Preventer with stainless steel body provides low hazard protection ZW215FP Fire Pump Suction Control Valve (Automatic Control Valve) controls the suction pressure to a fire pump, preventing cavitation and potential backflow conditions ZW205FP Pressure Relief Valve (Automatic Control Valve) protects fire protection systems by relieving high system pressures ZW209FP Pressure Reducing Valve (Automatic Control Valve) provides steady downstream pressure and allows high flow rates

12 in-building riser Wilkins building riser (WBR) Connects a water supply line from outside the building to the water system inside the building. Transitions horizontal run of pipe to vertical run for fire sprinkler riser, terminating above concrete slab. Eliminates joints under the slab Stainless steel construction Available 72 x 72 and 72 x 102 line extension sizes Lifting rings and thrust block anchor exclusive to Zurn is standard 4, 6, 8 and 10 pipe diameters Push on (C-900 or DIP) by grooved outlet with test cap and coupling (WBR and WBR6X8.5) Push on (C-900 or DIP) by flanged outlet (WBR-F) WBR-F WBR WBR6X8.5 page 015

13 backflow prevention Zurn patented compound check High hazard protection with a corrosion resistant, light weight design key features Provides a mechanical assist for a drip tight seal with low pressure loss Center guided stem designed for longevity and repeatability Serviceable in-line with cost-effective repair kits Lowest lifecycle cost of any manufacturer

14 double check large diameter The Zurn Wilkins Double Check Backflow Preventers (DC) provide low hazard protection for all water applications 350 Sizes 2-1/2 12 NRS (standard), OSY, PI or Butterfly (2-1/2"- 10") (optional) 350A Sizes 2-1/2 10 NRS (standard), OSY, PI or Butterfly (optional) 350AR Sizes 2-1/2 10 NRS (standard), OSY, PI or Butterfly 350ASTR Sizes 2-1/2 10 NRS (standard), OSY, PI or Butterfly 450 Sizes 2-1/2 10 NRS (standard), OSY, PI or Butterfly (4 10 ) optional) 350AST Sizes 2-1/2 10 NRS (standard), OSY, PI or Butterfly (optional) 450STR Sizes 4 10 NRS (standard), OSY, PI or Butterfly 450ST Sizes 4 10 NRS (standard), OSY, PI or Butterfly (optional)

15 backflow prevention 475STDA reduced pressure principle detector assembly detector assemblies (DA) Detects small water usage, either unauthorized use or a leak in the fire suppression system (static condition). Fire lines are generally not metered key features Double Check Detector Assemblies (DCDA) or Reduced Pressure Detector Assemblies (RPDA) options Serves as a water theft deterrent

16 double check detector large diameter The Zurn Wilkins Double Check Detector Backflow Preventers (DCDA) are ideal for low hazard protection, with a metered by-pass to detect leaks and unauthorized water use in unmetered fire sprinkler systems. 350DA Sizes 2-1/2 12 OSY (standard), PI or Butterfly (2-1/2"- 10") (optional) 350ADA Sizes 2-1/2 10 OSY (standard), PI or Butterfly (optional) 350ASTDAR Sizes 2-1/2 110 OSY (standard), PI or Butterfly (optional) 450DA Sizes 4 10 OSY (standard), PI or Butterfly (optional) 350ASTDA Sizes 2-1/2 10 OSY (standard), PI or Butterfly (optional) 450STDAR Sizes 4 10 OSY (standard), PI or Butterfly (optional) 450STDA Sizes 4 10 OSY (standard), PI or Butterfly (optional)

17 double check detector small diameter The Zurn Wilkins Double Check Detector Backflow Preventers (DCDA) are ideal for low hazard protection, with a metered by-pass to detect leaks and unauthorized water use in unmetered fire sprinkler systems. 950XLTDA Sizes 2 950XLTDABF Sizes 2

18 reduced pressure detector The Zurn Wilkins Reduced Pressure Detector Backflow Preventers (RPDA) provide protection where a high hazard exists in an unmetered fire protection system, with a metered by-pass to detect leaks and unauthorized water use 375ADAR 375DA Sizes 2-1/2 10 OSY (standard), PI or Butterfly (optional) 375ADA Sizes 2-1/2 10 OSY (standard), PI or Butterfly (optional) Sizes 2-1/2 10 NRS (standard), OSY, PI or Butterfly 375ASTDAR Sizes 2-1/2 10 OSY (standard), PI or Butterfly (optional) 475STDAR 475DA Sizes 4 10 OSY (standard), PI or Butterfly (optional) 475DAV Sizes 4 10 OSY (standard), PI or Butterfly (optional) Sizes 4 10 OSY (standard), PI or Butterfly (optional) 375ASTDA Sizes 2-1/2 10 OSY (standard), PI or Butterfly (optional) 475STDARV Sizes 4 10 OSY (standard), PI or Butterfly (optional) 475STDA Sizes 4 10 OSY (standard), PI or Butterfly (optional) 475STDAV Sizes 4 10 OSY (standard), PI or Butterfly (optional)

19 fire protection control valves ZW209FP pressure reducing valve fire protection valves Pressure reducing valve for fire protection applications Only manufacturer UL/c-UL Listed up to 10 FM approved No shut off valves in fire protection control valve pilotry connection types 150# flange 300# threaded 300# flange 300# grooved 5:13 Video Function of a ZW209FP page 026

20 automatic control valves (for larger systems) Fire systems can be complex, encompassing multiple control valve functions in order to provide adequate building safety 2:36 Video: Zurn Wilkins Pressure Reducing Valves ZW209FP ZW215FP pump suction control valve Sensing line plumbed to the inlet of the fire pump Pump begins to overdraft from the supply line (supply network). valve will begin to close, preventing a risk of damage to the supply network ZW205FP fire pump relief valve Relief valve, generally plumbed in a branch from the main fireline In the event that the upstream pressure exceeds a preset limit, valve will open, relieving pressure from the main ZW209FP pressure reduction valve Near constant pressure provided downstream regardless of water flow rate 2:36 Video: Zurn Wilkins Automatic Control Valves ZW215FP Fire Pump Suction Control Valve page 027

21 fire valves hose valve Model F100 and F100G Standpipe valve listed for use as fire department outlet connection. The Fire Ground Force will connect a hose, open the valve and manually fight the fire Can be used on a fire hose rack assembly Sizes: 1-1/2 and 2-1/2 Maximum inlet pressure: 300 psi Inlet connection: FNPT or Grooved Outlet connection: NH, FNPT or Special Thread (2-1/2 ) Available rough chrome plated (2-1/2) Standards Compliance: UL Listed C-UL, ULC Listed (2-1/2 only) FM Approved 212-F F100F 112-F100G page 028

22 fire valves restricting hose valve Model F105 Standpipe valve for hose stations Regulates pressure under FLOW conditions only Can be adjusted and set in the field while flow testing the standpipe riser Sizes: 1-1/2 and 2-1/2 Maximum inlet pressure: 175 psi Inlet connection: FNPT Outlet connection: NH, FNPT or Special Thread (2-1/2) Standards Compliance: UL Listed FM Approved 212-F105 page 029

23 check valves & riser checks check valves & riser checks Model F210 and Model F210R Provide zone water checking feature, as required by systems including but not limited to combined sprinkler standpipe piping systems. These valves ensure quick activation of sprinkler systems in the instance of a fire emergency. F210 used in conjunction with a FDC Check Trim Kits are sold separately and installed to complete riser checks F210R Sizes: 2, 2-1/2, 3, 4, 6, 8 Maximum pressure: 200 psi Standards Compliance: UL Listed C-UL, ULC Listed FM Approved 212-F210 4-F210R with trim kit installed 212-F210R page 030

24 commercial fire risers commercial fire risers Model FEZR Vertically mounted assemblies designed to connect a water supply line to a fire sprinkler system Each unit consists of a test and drain valve, a water flow detector switch, and a pressure gauge providing for the required system flow testing, alarm triggering upon activation of a fire sprinkler, draining of the system, and monitoring of the system water pressure Sizes: 2, 2-1/2, 3, 4 and 6 Maximum inlet pressure: 300 psi Inlet connection: Grooved Outlet connection: Grooved Standards Compliance: UL Listed FM Approved Listed by California State Fire Marshall 212-FEZR-TD page 031

25 test and drain valves test and drain valves Model FTP Provide for required water flow testing and draining of a sprinkler system with one valve In the test position this valve simulates flow of a single sprinkler with a 5.6 K-Factor orifice The drain position allows unrestricted flow for rapid draining of the system Clear sight glass plugs facilitates visual inspection of water flow through the valve Sizes: 1, 1-1/4, 1-1/2 and 2-1/2 Maximum inlet pressure: 300 psi Inlet connection: FNPT Outlet connection: FNPT Standards Compliance: UL Listed C-UL FM Approved 114-FTD-K56 page 032

26 shut-off valves fire OS&Y untapped Model F48OS&YF Untapped rising stem resilient wedge gate valve provides a visual indication of valves open/closed position Many jurisdictions require untapped OS&Y s Competitively priced Sizes: 2-1/2, 3, 4, 6, 8, 10 Standards Compliance: AWWA UL Listed C-UL, ULC Listed FM Approved page 033

27 shut-off valves Post indicator (PI) gate valve Provides a visual indication of the valve s open/closed position when coupled with an indicator post Non-rising stem gate valve with attachment plate for indicator post 48 outside stem & yolk (OS&Y) gate valve Provides a visual indication of valve s open/closed position Resilient wedge gate valve Flanged, grooved, or flanged x grooved connections Stand alone or on Zurn Wilkins backflow preventers 49 Butterfly Valve Integral supervisory switch with visual indicator Butterfly valve with grooved x grooved connections, grooved x flange connections and flange x groove connections

28 shut-off valves fire butterfly valves Model F49 Provides a slow opening anti-water hammer operation to control waterflow. An integral supervisory tamper switch provides a fire alarm control signal when the valve is moved from the open position. Sizes: 2-1/2, 3, 4, 6, 8 Maximum pressure: 300 psi Standards Compliance: UL Listed C-UL, ULC Listed FM Approved 4-F49 page 035

29 shut-off valves powerball butterfly valve Model F49BR and F49BRG Provide for system shutoff to facilitate repair and maintenance. Operated with a slow closing ¼ turn anti-water hammer valve. Tamper switches signal movement of the valve from the full open position to an alarm control panel, and to auxiliary equipment such as an indicating light or audible alarm in the area of the valve installation. Sizes: 1, 1-1/4, 1-1/2, 2 and 2-1/2 Grooved connections sizes: 1-1/4, 1-1/2, 2 and 2-1/2 Maximum working water pressure: 300 psi Standards Compliance: UL Listed C-UL FM Approved 112-F49BR 2-F49BRG page 036

30 fire department connections fire department connections Model FDC2 Fire Department Connections provide a means for firefighters to connect hose lines to a fire sprinkler system to supplement the domestic water supply pressure. Standpipe connection: 4 NPT Siamese inlet connections: 2 x 2-1/2 NH Maximum pressure: 300 psi Options: straight or 90 degree body style Standards Compliance: UL Listed C-UL, ULC Listed FM Approved 4x212-FDC2-EX-SC 4x212-FDC2-EX90-SC page 037

31 new products fire protection grooved couplings reducing, rigid, flex Model FP23, FP23R, FP23F Couplings are listed to join grooved pipes together. Rigid Couplings provide sturdy inflexible joints comparable to flanged, welded, or threaded connections. They are designed to prevent angular and axial deflection of connected pipes. Flexible Couplings allow joints to flex at the connection without leakage. They meet flexure requirements for structural settling, interbuilding piping, and seismic motion. 4-FP23R Reducing Couplings provide a flexible style joint between pipes of different sizes. Each reducing coupling makes a connection that would otherwise require two separate couplings and a reducer. Sizes: 1-1/4" 10" (Rigid and Flex), 1-1/2" by 1-1/4" to 8" by 6 (Reducing) Standards Compliance: UL Listed C-UL, ULC Listed FM Approved 4x2-FP23 page 038

32 Zurn fire protection fittings all compliant UL Listed C-UL, ULC Listed FM Approved Elbows (FP52) and Tees (FP53) branch connections for 1 ¼ through 10 pipes and are available tee short radius (S), tee standard radius and reducing branch tree Crosses (FP56) standard grooved fittings to connect runs of pipe in crossing directions Caps (FP3) standard grooved pipe ends Mechanical Tees (FP63) provide fast, convenient mid-pipe branch connections without welding Grooved Flanges (FP8) standard converters for connecting flanges to grooved or threaded pipes Grooved Reducers (FP51) page 039 connect pipes of different sizes. Concentric grooved-grooved, groovedmale, and grooved-female options are available. Grooved-grooved reducers are also available with eccentric (E) configurations

33 Zurn fire protection components couplings wet system

34 pressure control valve pressure control valve Model P4000A Prevents pressure build-up in a fire protection system whenever the pressure exceeds the setting of the spring caused by pumps, elevated piping, and thermal expansion Standard adjustability psi Also available in psi version Cast bronze and stainless steel construction Standards Compliance: UL Listed C-UL FM Approved

35 ancillary products Ball Valve Monitor Switch (BVMS) Mounted on a backflow preventer s ball valve shutoffs in a fire sprinkler system, it will signal if ball valve handle is moved from an open position Fixed Air Gaps Collects water discharge from reduced pressure backflow assemblies, duracoated cast iron body Gate Valve Supervisory Switch (OSY-40) Used to monitor the position of and OS&Y type gate valve. Setters Used with 400 series DI and Stainless backflows, valve setters ease installation time and eliminate the need for concrete thrust blocks.

36 fire valves Pressure-Tru *Field adjustable valves can be ordered as factory set and adjusted in the field Application Use Size Factory Set (set at the factory to criteria furnished by the customer) Field Adjustable* (sized and set in the field by the customer) S t a n d p i p e Automatic Fire Sprinkler System Hose Valve Floor Control Fire Department Hose Rack 2 ½ ZW4004 Z ½ ZW ½ ZW4000 Z ½ ZW4100 Z ½ Z ½ ZW4100 page Z

37 control valves for fire systems Typical High Rise Fire Sprinkler System As the industry leader, with 60-70% market share in smart fire protection solutions, we deliver water safety, and pressure management solutions with backflow prevention assemblies and pressure reducing valves that are easily serviced and provide the lowest life-cycle costs. types Hose Valves On / Off Pressure Restricting Size 2 ½ Range psi Size 1 ½ Range psi Multiple hose thread options Direct Acting Pressure Reducing All sizes Range over 175 psi Sprinkler Floor Control Valves Direct Acting Pressure Reducing All sizes Range over 175 psi Sprinkler Floor Control Valve pressure reducing key features Used when fire sprinkler system pressure exceeds 175 psi to reduce pressure below 175 psi Provide water on/off control Provide check feature for sprinkler applications Inline globe (IL) and angle bodies Threaded and grooved connections; multiple thread options Tapped and plugged for gauges Commonly in risers in stairways Hose Valve

38 sprinkler floor control Pressure-Tru sprinkler valves Serves as a floor control valve, indicating valve, and check valve in automatic sprinkler systems Z3004SS floor control valve 1½ 2½ key features Zurn has more benefits than any competitor Cleanable and repairable while inline Limits static outlet pressure below 175 psi as required by NFPA (National Fire Protection Association) Regulates pressure under both flow and no-flow conditions Supervisory switch (SS option) Inline globe or angle body configurations options Grooved or threaded connections 4:20 Video: Zurn Wilkins Pressure Reducing Valves ZW4004 Fire Sprinkler Control Valve Field Adjustable Factory Set ZW4104 Factory Set 1-1/2" Pressure Reducing Sprinkler System Valves Z3004 Field Adjustable 2-1/2" Pressure Reducing Sprinkler System Valves page 045 ZW4004G Factory Set 2-1/2" Pressure Reducing Sprinkler System Valves

39 hose valves Z3000 hose valve Pressure-Tru Hose Valves Serves as a standpipe valve for individual hose stations for CLASS I, II, and III systems 1½ 2½ key features Cleanable and repairable while inline Regulates pressure under both FLOW / NO-FLOW conditions Limits static outlet pressure below 175 psi as required by NFPA Factory set or field adjustable outlet pressure setting Inline globe or angle body configurations Grooved or threaded inlets; local thread options available Available rough chrome finish 4:34 Video: Zurn Wilkins Pressure Reducing Valves Z3000 Series for Fire Protection Systems Field Adjustable Factory Set Z2100 Field Adjustable 1-1/2" Pressure Reducing Hose Valve ZW4100 Z4100 Factory Set 1-1/2" Pressure Reducing Hose Valve Z3000 Field Adjustable 2-1/2" Pressure Reducing Hose Valve page Z ZW4000G Factory Set 2-1/2" Pressure Reducing Hose Valve

40 Test Your Knowledge What are Zurn fire valves top 3 benefits? A. High durability and reliability B. Cleanable and repairable while inline C. Water conservation D. Diverse set of fire valves

41 how to specify step-by-step 1 2 standpipe application Automatic fire sprinkler system or hose valve use Automatic fire sprinkler system for floor control, hose valve for fire department, or hose valve for hose rack 3 size 2-1/2 or 1-1/2 4 factory set vs. field adjustable Set by the factory according to client specifications or field adjustable by client

42 resources factory set sizing web tool size and set direct acting correctly page 056

43 resources tools Create unlimited configurations Solidify your basis of design Generate your submittal package Edit, share and copy projects Zurn.com tools inspec Manufacturer Cross Reference ARCAT Create configurations, solidify your basis of design, generate your submittal package, edit/share/copy projects Select a manufacturer, then product, type, or competitor product number to find the corresponding Zurn Product Review CAD, BIM, and spec files MasterSpec BIM/Revit Files Cross Reference Guides Product Warranties Review spec files Browse BIM objects Review cross reference guides for individual products Review One Zurn terms and conditions page 057

44 resources sample order forms on zurn.com To ensure customer receives the correct product on time for their project Forms for Hose Valves Z3000 Z2100 ZW4000 / Z4000G Z2105 Z3005 ZW4100 Forms for Floor Control Valves Z3004 / ZW3004SS ZW4004 / ZW4004SS ZW4104 / ZW4104SS

45 summary Zurn overview For more than a century, Zurn Engineered Water Solutions has established itself as an innovator and leading manufacturer of highly engineered water product solutions. Markets We Serve Zurn Engineered Water Solutions is a recognized leader in commercial, municipal, and industrial markets, delivering sustainable building solutions for new construction and retrofit applications. Industry Leading Product Lines The Zurn product offering includes items such as specification drainage products, manual and sensor operated flush valves, radiant heating systems, snow melt systems, trench drain systems, backflow and fire protection systems, and much, much more. Solutions We Provide At Zurn we are committed to providing smart solutions that save time and money. Our goal is serving the customer through innovation, continuous improvement, and assurance behind every installation. One Choice. One Zurn. Choose Zurn for a reliable, recognized manufacturer to supply your entire installation, from behind the wall rough-in, to finished trim product and fixture systems. page 061

46 resources support address phone online 511 Freshwater Way Milwaukee, WI toll-free ONE-ZURN zurn.com Product Pages Tools, Specifications, & Resources Vertical Market Solutions inspec Manufacturer Cross Reference ARCAT MasterSpec SpecBuilder Specifiers BIM/Revit Files zurn.com/resources/product-training Zurn Product - Overview How to Install and Support linkedin/zurn Industries, LLC facebook/zurn Industries, LLC youtube/zurn twitter/zurnind page 062

Flow Control for Fire Protection

Flow Control for Fire Protection Flow Control for Fire Protection Valve Solutions From An Industry Leader AmesFireWater.com Count on the Fire Protection Leader for Reliable Flow Control Solutions Ames provides a range of high-quality

More information

Flow Control for Fire Protection

Flow Control for Fire Protection Flow Control for Fire Protection Valve Solutions From An Industry Leader AmesFireWater.com Count on the Fire Protection Leader for Reliable Flow Control Solutions Ames provides a range of high-quality

More information

DIVISION 21 - FIRE SUPPRESSION

DIVISION 21 - FIRE SUPPRESSION DIVISION 21 - FIRE SUPPRESSION DESIGN CRITERIA It is the policy of UC Davis to install fire sprinkler systems in all new construction/facilities. If the building is classified as a pole barn, shed, carport,

More information

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM SECTION 21 0000 AUTOMATIC FIRE SPRINKLER SYSTEM PART 1 GENERAL 1.1 QUALITY ASSURANCE A. Codes and Standards: 1. FBC (Florida Building Code 2015) 2. FBC (Florida Fire Code 2015) 3. NFPA #13R (Standard for

More information

DIVISION 21 - FIRE SUPPRESSION

DIVISION 21 - FIRE SUPPRESSION DIVISION 21 - FIRE SUPPRESSION DESIGN CRITERIA It is the policy of UC Davis to install fire sprinkler systems in all new construction/facilities. If the building is classified as a pole barn, shed, carport,

More information

UL/FM Fire Protection Products. Reliable fire protection products for your commercial, industrial, or institutional property.

UL/FM Fire Protection Products. Reliable fire protection products for your commercial, industrial, or institutional property. UL/FM Fire Protection Products Reliable fire protection products for your commercial, industrial, or institutional property. Reliable UL/FM Fire Protection Products Markets Power Institutional Company

More information

SPRINKLERS TABLE OF CONTENTS

SPRINKLERS TABLE OF CONTENTS SPRINKLERS TABLE OF CONTENTS SECTION 21 13 13 WET PIPE SPRINKLER SYSTEMS SECTION 211313 - WET PIPE SPRINKLER SYSTEMS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract,

More information

UC Santa Cruz Campus Design Guide. Includes the following sections: None DESIGN REQUIREMENTS

UC Santa Cruz Campus Design Guide. Includes the following sections: None DESIGN REQUIREMENTS DIVISION 21 - FIRE SUPPRESSION Includes the following sections: None DESIGN REQUIREMENTS It is the policy of City of Santa Cruz to install fire sprinkler systems in all new construction/facilities. If

More information

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant. SECTION 218800 - FIRE PROTECTION 1. GENERAL A. Provisions of Division 1, GENERAL REQUIREMENTS, and Section 230000, MECHANICAL GENERAL CONDITIONS, and Section 230050, SEISMIC PROTECTION are a part of this

More information

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8 City of Ottawa Project No. CR006230 Page 1 of 8 PART 1 - GENERAL 1.1 Reference Standards.1 Conform to the following:.1 Provincial and municipal building and fire regulations as approved by Provincial Fire

More information

UL/FM Fire Protection Products Setting the Standard

UL/FM Fire Protection Products Setting the Standard UL/FM Fire Protection Products Setting the Standard Markets Power Institutional Company Overview Mueller Canada is a leader in high-quality commercial and institutional fire protection products, offering

More information

UL/FM Fire Protection Products Setting the Standard

UL/FM Fire Protection Products Setting the Standard UL/FM Fire Protection Products Setting the Standard Markets Power Institutional Company Overview Mueller Co. is a leader in high-quality commercial and institutional fire protection products, offering

More information

UL/FM Fire Protection Products. Reliable fire protection products for your commercial, industrial, or institutional property.

UL/FM Fire Protection Products. Reliable fire protection products for your commercial, industrial, or institutional property. UL/FM Fire Protection Products Reliable fire protection products for your commercial, industrial, or institutional property. Reliable UL/FM Fire Protection Products Markets Power Institutional Company

More information

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION SECTION 21 1301- FIRE-SUPPRESSION SYSTEMS PART 1 - GENERAL 1.1 SUMMARY: A. This Section includes fire-suppression piping and equipment for the following building systems: 1. Wet-pipe, fire-suppression

More information

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES DIVISION 21 FIRE SUPPRESSION PART 1 GENERAL 1.01 DESCRIPTION A. Provide UL listed, FM approved listed fire protection specialties or accessories as required by either the equipment manufacturer or the

More information

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University. 15500 - FIRE PROTECTION PART I DESIGN GUIDELINES A. General 1. Vertical fire pumps shall not be used at the University. 2. coupling piping shall be permitted for sprinkler and standpipe systems only. B.

More information

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following: SECTION 21 10 00 - WATER-BASED FIRE-SUPPRESSION PART I - GENERAL 1.1 SUMMARY A. Inclusion of sprinkler and standpipe systems shall be as determined by NFPA National Fire Code pamphlet 101 and program statement.

More information

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements Module 3 Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements 1 WATER-BASED SUPPRESSION SYSTEMS-PART TWO This module covers: 1. Ohio Building Code requirements and when and why

More information

B. Related Sections: The following Sections contain requirements that relate to this Section.

B. Related Sections: The following Sections contain requirements that relate to this Section. SECTION 211313- FIRE-SUPPRESSION PIPING PART1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general prov1s1ons of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

DIVISION 21 FIRE SUPPRESSION FIRE SUPPRESSION GENERAL PROVISIONS .1 PREPARATION OF CONTRACT DOCUMENTS

DIVISION 21 FIRE SUPPRESSION FIRE SUPPRESSION GENERAL PROVISIONS .1 PREPARATION OF CONTRACT DOCUMENTS 2006 Edition, Published January 1, 2006; Division Revision Date: June 30, 2016 21 00 00. FIRE SUPPRESSION 21 00 03. GENERAL PROVISIONS.1 PREPARATION OF CONTRACT DOCUMENTS.1.1 PLUMBING CONTRACT: Include

More information

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1 GENERAL: 1. All fire protection systems shall be installed in accordance with the International Fire Code and applicable NFPA standards. This guideline provides additional requirements for the design and

More information

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco. TN-25 Tunnel Fire Protection System Safer. Smarter. Tyco. Expert Fire Protection for Tunnels Tyco provides a complete fire protection solution to protect the infrastructure of tunnels. Whether it is rail,

More information

SAFETY PLUMBING PACKAGES. Quality Products & Value Packages SUSTAINABILITY. Residential Solutions ANTI-SCALE SYSTEMS FIRE PROTECTION

SAFETY PLUMBING PACKAGES. Quality Products & Value Packages SUSTAINABILITY. Residential Solutions ANTI-SCALE SYSTEMS FIRE PROTECTION Quality Products & Value Packages Residential Solutions FIRE PROTECTION COMFORTSUSTAINABILITYCONTROL PRESSURE REGULATORS TRENCH DRAINSHVAC SYSTEMS SAFETY ANTI-SCALE SYSTEMS HEATING & COOLING CONTROLS PLUMBING

More information

SECTION FIRE-SUPPRESSION STANDPIPES

SECTION FIRE-SUPPRESSION STANDPIPES PART 1 - GENERAL 1.1 DESCRIPTION Fire-suppression wet and manual dry standpipes. 1.2 SCOPE OF WORK SECTION 21 12 00 A. Design, installation and testing shall be in accordance with NFPA 14 except for specified

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 21 1314D - AUTOMATIC SPRINKLER SYSTEMS (DRY-PIPE) PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

FIRE SUPPRESSION SPRINKLER SYSTEM

FIRE SUPPRESSION SPRINKLER SYSTEM PART 1 GENERAL 1.01 DESCRIPTION A. The provisions of the General Requirements, Supplementary Requirements, and Division 1 apply to the plumbing work specified in this Division. B. The requirements of this

More information

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements. FIRE PROTECTION GENERAL INFORMATION 1.1 Refer to Section 230000 for General Mechanical Requirements. 1.2 Refer to Section 230529 for Hangers and Supports. 1.3 Refer to Section 230553 for Pipe and Equipment

More information

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section PART 1 - GENERAL 1.00 GENERAL PROVISIONS A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section 1.01 DESCRIPTION OF WORK A. Work Included: Provide

More information

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1 TO CONTRACT DOCUMENTS ENTITLED: PROJECT MANUAL FOR: Women s and Children s Hospital New Water Service Main PROJECT NUMBER: CP172631 ADVERTISEMENT DATE: July

More information

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers. SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

A. This section includes design and performance information for fire protection and suppression systems.

A. This section includes design and performance information for fire protection and suppression systems. SECTION 21 00 10: FIRE PROTECTION SYSTEM DESIGN 1. SUMMARY A. This section includes design and performance information for fire protection and suppression systems. 2. GENERAL A. All fire protection materials

More information

New Construction Fire Inspection Process

New Construction Fire Inspection Process New Construction Fire Inspection Process This document is intended to provide the Owner, Designer, and/or Contractor of new construction with an outline of required fire inspections and with the specific

More information

MODULE 2. Water-Based Suppression System Basics

MODULE 2. Water-Based Suppression System Basics MODULE 2 Water-Based Suppression System Basics Based on the Ohio Building Code (OBC) National Fire Protection Association (NFPA) & Ohio Fire Code (OFC) 1 WATER-BASED SUPPRESSION SYSTEM BASICS-PART ONE

More information

Oxnard Fire Department 360 W. Second Street Oxnard, CA (805) Fax (805)

Oxnard Fire Department 360 W. Second Street Oxnard, CA (805) Fax (805) Oxnard Fire Department 360 W. Second Street Oxnard, CA 93030 (805) 385-7722 Fax (805) 385-8009 FIVE YEAR CERTIFICATION REPORT Service and maintenance report for automatic fire extinguishing systems, including

More information

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD STANDPIPE SYSTEMS PURPOSE This standard outlines the general requirements for the installation of standpipe systems. CODE REFERENCES

More information

UBC Technical Guidelines Section Edition Fire Protection General Requirements Page 1 of 6

UBC Technical Guidelines Section Edition Fire Protection General Requirements Page 1 of 6 Page 1 of 6 1.0 GENERAL 1.1 Related UBC Guidelines.1 Section 20 00 05 Mechanical - General Requirements.2 Section 22 05 00 Plumbing - General Requirements.3 UBC Standard Fire Hydrant Drawings.4 Section

More information

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION WET-PIPE SPRINKLER SYSTEMS SECTION 21 1300 S PART 1 -GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

DIVISION 21 FIRE SUPPRESSION FIRE SUPRESSION

DIVISION 21 FIRE SUPPRESSION FIRE SUPRESSION DIVISION 21 FIRE SUPPRESSION 21 00 00 FIRE SUPRESSION 21 01 00 Operation and Maintenance of Fire Suppression 21 01 10 Operation and Maintenance of Water Based Fire Suppression Systems 21 01 20 Operation

More information

SECTION DRY-PIPE SPRINKLER SYSTEMS

SECTION DRY-PIPE SPRINKLER SYSTEMS SECTION 21 1300 S PART 1 -GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM SECTION 213100 WET PIPE FIRE PROTECTION SPRINKLER SYSTEM PART 1 - GENERAL 1.01 GENERAL REQUIREMENTS A. The requirements of the General Conditions and Supplementary Conditions apply to all work herein.

More information

Your Single Source Partner with Watts for a Comprehensive Suite of Innovative Water Solutions

Your Single Source Partner with Watts for a Comprehensive Suite of Innovative Water Solutions Your Single Source Partner with Watts for a Comprehensive Suite of Innovative Water Solutions WATER UALITY ACKFLOW REVENTION LUMBING & LOW CONTROL OneWattsWater.com Watts is the Smart Choice Foodservice

More information

Course FP100 BACKFLOW PREVENTERS (BFPs) 101 FOR AUTOMATIC FIRE SPRINKLER SYSTEM M. Nabeel Waseem, M.Eng, PE, CFPS 2018

Course FP100 BACKFLOW PREVENTERS (BFPs) 101 FOR AUTOMATIC FIRE SPRINKLER SYSTEM M. Nabeel Waseem, M.Eng, PE, CFPS 2018 Course FP100 BACKFLOW PREVENTERS (BFPs) 101 FOR AUTOMATIC FIRE SPRINKLER SYSTEM M. Nabeel Waseem, M.Eng, PE, CFPS 2018 1 Introduction If you have ever been exposed to automatic fire sprinkler system, there

More information

SECTION DOMESTIC WATER PIPING SPECIALTIES

SECTION DOMESTIC WATER PIPING SPECIALTIES SECTION 22 11 19 DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 21 1314W - AUTOMATIC SPRINKLER SYSTEMS (WET PIPE SYSTEMS) PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

CITY OF PASADENA FIRE DEPARTMENT

CITY OF PASADENA FIRE DEPARTMENT Page 1 of 8 CITY OF PASADENA FIRE DEPARTMENT INSTALLATION OF COMMERCIAL SPRINKLERS (Revised 12/10/2014) SCOPE: This standard applies to the design and installation of automatic fire sprinkler systems in

More information

WET-PIPE SPRINKLER SYSTEMS

WET-PIPE SPRINKLER SYSTEMS SECTION 211313 - WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipes, fittings, and specialties. 2. Fire-protection valves. 3. Fire-department connections. 4. Sprinklers.

More information

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL SECTION 21 13 16 DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No SECTION 213113 - ELECTRIC-DRIVE, CENTRIFUGAL FIRE PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD INSTALLATION OF COMMERCIAL FIRE SPRINKLER SYSTEMS STANDARD #C-001 EFFECTIVE 03-25-2009 PURPOSE: To ensure that sprinkler plans submitted for review contain

More information

Environmental Health & Safety

Environmental Health & Safety Environmental Health & Safety Oklahoma State University FIRE SPRINKLER SYSTEM STANDARD Environmental Health and Safety University Health Services Suite 002 Stillwater, OK 74078 (405) 744-7241 www.ehs.okstate.edu

More information

2. Welding Materials and Procedures shall conform to the ASME Code.

2. Welding Materials and Procedures shall conform to the ASME Code. PART 1 GENERAL 1.01 Scope of Standard A. The design guidelines contained herein include the requirements for systems, materials, fittings and valves utilized for fire protection systems at Sam Houston

More information

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint. (816) 373-4878 U1208-01/FAI29-029 (573) 751-2624 SECTION 2 105 17 - SLEEVES AND SLEEVE SEALS FOR FIRE-SUPPRESSION PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the

More information

Your Single. Source. Partner with Watts Water. for a Comprehensive Suite. of Innovative Water Solutions. OneWattsWater.com

Your Single. Source. Partner with Watts Water. for a Comprehensive Suite. of Innovative Water Solutions. OneWattsWater.com Your Single Source Partner with Watts Water for a Comprehensive Suite of Innovative Water Solutions OneWattsWater.com SINCE 1874 INNOVATIVE SOLUTIONS RESIDENTIAL CONST COMMERCIAL CONSTRUCTION MUNICIPAL

More information

SECTION DRY-PIPE SPRINKLER SYSTEMS

SECTION DRY-PIPE SPRINKLER SYSTEMS Ul611-0l SECTION 211316- DRY-PIPE SPRINKLER SYSTEMS PARTl-GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions, and Division 1 Specification

More information

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM SECTION 21 10 00 PART 1 - GENERAL 1.1 CODES A. Work shall conform to NFPA 13 Sprinkler Systems, 2002 Edition and NFPA 24 Outside Protection, 2002 Edition. NFPA 14 Standpipe Systems, 2000 Edition and International

More information

Solutions at every turn.

Solutions at every turn. Solutions at every turn. GROOVED PIPING SYSTEMS HVAC INDUSTRY www.grinnell.com HVAC GROOVED PIPING SYSTEMS PROS TURN TO GRINNELL PRODUCTS GRINNELL Mechanical Products, a premier brand of Tyco International,

More information

Gas Station & C Store SECTION CWM Job No

Gas Station & C Store SECTION CWM Job No SECTION 21 1300 - PART 1 - GENERAL 1.1 WORK INCLUDED A. Provide labor, materials, equipment and services to perform operations required for the complete installation and related Work as required in Contract

More information

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI Hydraulic Institute Standards. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Port of St Helens SIA Aircraft Hanger Scappoose, OR

Port of St Helens SIA Aircraft Hanger Scappoose, OR Port of St Helens SIA Aircraft Hanger Scappoose, OR AUTOMATIC FIRE SPRINKLER SYSTEM REVISION 2 MARCH 12, 2018 Scope: Furnish and install foam and water fire protection system including underground entrance

More information

Design & Construction Standards, Revised January

Design & Construction Standards, Revised January PART 1 GENERAL 1.01 Scope of Standard A. This standard provides general requirements of The University of Texas at Austin for the design and construction of standpipe systems to include combination standpipe

More information

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION WET-PIPE SPRINKLER SYSTEMS SECTION 21 13 13 WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

City of Vista Fire Department

City of Vista Fire Department City of Vista Fire Department Development Services Section 600 Eucalyptus Avenue, Vista CA 92084 Guideline: Underground Piping for Private Fire Hydrants & Fire Sprinkler Supply. Updated: January, 2008

More information

ADDENDUM NO. 3 March 19, 2018

ADDENDUM NO. 3 March 19, 2018 ADDENDUM NO. 3 March 19, 2018 PROJECT: MT. VIEW ELEMENTARY CASSIA SCHOOL DISTRICT NO 151 BURLEY, IDAHO The following addenda apply to the Project Manual and / or Drawings for this project and shall be

More information

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions: SECTION 21 13 13 WET-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA August 14, 2013 Sprinkler 126k 1. PRODUCT DESCRIPTION Viking Institutional Style Quick Response Flush Horizontal Sidewall Sprinklers are small, flush, solder link and lever sprinklers made with tamper-resistant

More information

HOW COMMERCIAL FIRE PROTECTION SPRINKLER SYSTEMS REALLY OPERATE

HOW COMMERCIAL FIRE PROTECTION SPRINKLER SYSTEMS REALLY OPERATE A Guide for Fire Sprinkler Maintenance and Operation Commercial fire protection sprinkler systems have been saving lives and reducing property damage for more than a century. New England s textile mills

More information

DARTMOUTH COLLEGE DESIGN November 15, 2007 & CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN November 15, 2007 & CONSTRUCTION GUIDELINES SECTION 15300 FIRE PROTECTION PART 1 DESIGN DIRECTIVES 1.1 DESIGN CRITERIA A. Dartmouth College is currently insured by Factory Mutual. References to the owner s insurance company in this specification

More information

TABLE OF CONTENTS DIVISION 21- FIRE SUPPRESSION PAGES SECTION WATER BASED FIRE PROTECTION SYSTEMS... 5

TABLE OF CONTENTS DIVISION 21- FIRE SUPPRESSION PAGES SECTION WATER BASED FIRE PROTECTION SYSTEMS... 5 DOC Cremer Heating and Hot Water Plant Project Number: M 1411-04 TABLE OF CONTENTS DIVISION 21- FIRE SUPPRESSION PAGES SECTION 21 30 00- WATER BASED FIRE PROTECTION SYSTEMS... 5 SECTION 22 40 00 -PLUMBING

More information

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE Page 1 of 12 1. DESCRIPTION (Refer to Figures 1-6.) Viking Electric/Pneu-Lectric Double Interlocked Preaction Systems utilize a Viking deluge valve, pneumatic supervision of the automatic sprinkler system,

More information

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST STANDPIPE SYSTEMS

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST STANDPIPE SYSTEMS July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST STANDPIPE SYSTEMS Address: Permit #: Inspector: Date Inspected: Status: Inspector: Date Inspected: Status: A-Approved;

More information

esfr dry pendent sprinkler Vk501 (k14.0)

esfr dry pendent sprinkler Vk501 (k14.0) September 13, 2012 Sprinkler 122a 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Dry Pendent Sprinkler VK501 is a fast response fusible element type sprinkler designed for use in storage

More information

North Hanover Township School District North Hanover Township, New Jersey

North Hanover Township School District North Hanover Township, New Jersey SECTION 211313 - WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipes, fittings, and specialties. 2. Fire-protection valves. 3. Fire-department connections. 4. Sprinklers.

More information

esfr dry pendent sprinkler Vk502 (k14.0)

esfr dry pendent sprinkler Vk502 (k14.0) Page 1 of 11 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Dry Pendent Sprinkler VK502 is a fast response fusible element type sprinkler designed for use in storage areas subject to freezing

More information

SECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS

SECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS SECTION 15501 WET AUTOMATIC FIRE SPRINKLER SYSTEMS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Wet automatic fire sprinkler systems including fire pump, fire pump controller, alarms, safety devices,

More information

A. All Fire Suppression System design and installation shall comply with the most current and adopted version of NFPA 13.

A. All Fire Suppression System design and installation shall comply with the most current and adopted version of NFPA 13. 21 10 00 PART 1 - GENERAL 1.01 SCOPE A. The following standards and procedures apply to the design and installation of all wet pipe and dry pipe sprinkler systems. The design of fire suppression systems

More information

TOTALPAC2 Integrated Fire Protection System

TOTALPAC2 Integrated Fire Protection System TOTALPAC2 Integrated Fire Protection System Page 1 of 8 General 1. Applicable Standards The TOTALPAC2 Surefire complies with the following standards: - NFPA-13 Sprinkler Systems; - NFPA-15 Water Spray

More information

UL/FM Fire Protection Products

UL/FM Fire Protection Products UL/FM Fire Protection Products Setting the Standard Markets Power Industrial Company Overview Since 1857, the Mueller name has been associated with dependable Water and Gas distribution products around

More information

SECTION FIRE PROTECTION

SECTION FIRE PROTECTION SECTION 15300 - FIRE PROTECTION PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR

More information

FIVE YEAR AUTOMATIC FIRE EXTINGUISHING SYSTEMS CERTIFICATION REPORT

FIVE YEAR AUTOMATIC FIRE EXTINGUISHING SYSTEMS CERTIFICATION REPORT SANTA MONICA FIRE DEPARTMENT Fire Prevention Division 333 Olympic Drive 2 nd Floor Santa Monica, CA 90401 310-458-8915 / Fax 310-395-3395 FIVE YEAR AUTOMATIC FIRE EXTINGUISHING SYSTEMS CERTIFICATION REPORT

More information

AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)

AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations) AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations) This standard applies to the design and installation of automatic fire sprinkler systems in conjunction with

More information

SECTION FIRE SUPPRESSION SYSTEMS

SECTION FIRE SUPPRESSION SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section. 1.2

More information

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code Part 1 - GENERAL 1.1 DESCRIPTION OF WORK A. Design and installation of an engineered Kidde ECS Advanced Delivery Systems (ADS), clean agent/waterless fire suppression system employing 3M Novec 1230 waterless

More information

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures Please note this is not an all-inclusive list. The type and complexity of your project

More information

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA Page 1 of 8 1. PRODUCT DESCRIPTION Viking Institutional Style Quick Response Standard Coverage/Extended Coverage Flush Pendent Sprinklers are small, flush, solder link and lever sprinklers made with tamper-resistant

More information

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES SECTION 21 13 00 - FIRE SUPRESSION SPRINKLER SYSTEMS SCOPE OF WORK This standard provides general guidance concerning the specific preferences of The University of South Alabama for automatic fire sprinkler

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE October 10, 2008 Deluge Devices 281a 1. PRODUCT DESCRIPTION The Viking Model C-1 is a rate-of-rise releasing device for use on hydraulic and pneumatic release systems controlling operation of Viking deluge

More information

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES SECTION 21 30 00 FIRE PUMPS GENERAL This standard provides general requirements of The University of South Alabama in Mobile Alabama for fire pumps. This document is not intended to serve as a guide specification.

More information

SECTION FIRE-SUPPRESSION SYSTEMS

SECTION FIRE-SUPPRESSION SYSTEMS SECTION 13900 FIRE-SUPPRESSION SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Automatic wet-type, Class I, fire-suppression standpipes and branches for sprinklers. 2. Wet-pipe, fire-suppression

More information

A. Standard-Pressure Piping System Component: Listed for 175-psig minimum working pressure.

A. Standard-Pressure Piping System Component: Listed for 175-psig minimum working pressure. SECTION 211313 - WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipes, fittings, and specialties. 2. Fire-protection valves. 3. Fire-department connections. 4. Sprinklers.

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE January 27, 2012 311a 1. DEsCrIpTIoN (Refer to Figures 1-3.) Viking supervised Single Interlocked Preaction Systems utilize a Viking Deluge Valve and a pneumatically pressurized automatic sprinkler system.

More information

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings. DIVISION 21 21 05 00 COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe, fittings, sleeves, escutcheons, seals, and connections for sprinkler systems. 1.2 RELATED REQUIREMENTS

More information

Essex County College - West Essex Campus Addition And Renovations dlb # / 11-14

Essex County College - West Essex Campus Addition And Renovations dlb # / 11-14 SECTION 210523 - GENERAL-DUTY VALVES FOR WATER-BASED FIRE-SUPPRESSION PIPING PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary

More information

Series 20 Dual Check Backflow Preventers

Series 20 Dual Check Backflow Preventers Series 20 Dual Check Backflow Preventers Excellence Matters Specify It! A Division of Watts Regulator Company 427 North Market Blvd Suite #9 Sacramento, CA 9584 Phone: 96-928-02 Fax: 96-928-9 www.amesfirewater.com

More information

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO SECTION 210523 - GENERAL-DUTY VALVES FOR WATER-BASED FIRE-SUPPRESSION PIPING PART 1 - GENERAL 1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary

More information

SECTION WATER BASED FIRE SUPPRESSION SYSTEMS

SECTION WATER BASED FIRE SUPPRESSION SYSTEMS PART 1: GENERAL 1.01 Scope of Standard A. This standard provides general guidance concerning the specific preferences of Texas State University-San Marcos for automatic fire sprinkler and standpipe systems.

More information

AGF Manufacturing Inc. Inspector's Test and Drain Valves for Residential and Commercial Wet Fire Sprinkler Systems

AGF Manufacturing Inc. Inspector's Test and Drain Valves for Residential and Commercial Wet Fire Sprinkler Systems AGF Manufacturing Inc. Inspector's Test and Drain Valves for Residential and Commercial Wet Fire Sprinkler Systems BR-TESTa ndrain_2017 1/17 Reliability, Versatility, Code Compatibility TESTa ndrain The

More information

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950 Technical Services 00--9 +-0--0 www.tyco-fire.com Model CV-FR Riser Check Valves to Inch (DN0 to DN00) General Description The TYCO Model CV-FR Riser Check Valve is a compact and rugged swingtype unit

More information

ISO9001:2008 Cert Certified FIRE HYDRANTS. since SFFECO

ISO9001:2008 Cert Certified FIRE HYDRANTS. since SFFECO ISO9001:2008 Cert. 403 Certified FIRE HYDRANTS SFFECO since www.sffeco.com DRY BARREL FIRE HYDRANT Meets all applicable parts of ANSI/AWWA C502 standard UL Listed (EX16453) and FM Approved (FM1510) 250

More information

PHYSICAL FACILITIES. 1 General. 2 Related Requirements. 5 Quality Assurance. 3 Wiring. 4 Submittals

PHYSICAL FACILITIES. 1 General. 2 Related Requirements. 5 Quality Assurance. 3 Wiring. 4 Submittals 1 General 1.1 Provide all material, labor, engineering and operations for the installation of complete and operable fire suppression systems as shown in the job scope and as specified herein. 1.2 Provide

More information