EX products Materials for applications in hazardous environments

Size: px
Start display at page:

Download "EX products Materials for applications in hazardous environments"

Transcription

1 EX products Materials for applications in hazardous environments

2 EX Certification > WHAT IS ATEX? ATEX is a European Directive (94/9/EC) valid for products to be used within an explosive atmosphere. The ATEX directive has been in force throughout the European Union since July 2003, replacing the existing different national and European legislation relating to explosive atmospheres. ATEX= ATmosphere EXplosive > WHY ATEX? An ambience with the potential to become an explosive atmosphere during operating conditions and/or under the influence of the environment is defined as a potentially explosive atmosphere. Products covered by directive 94/9/EC are defined as intended for use in potentially explosive atmospheres. Directive 94/9/EC defines an explosive atmosphere as a mixture of: a) flammable substances gases, vapors, mists or dusts b) with air c) under specific atmospheric conditions d) in which, after ignition has occured, combustion spreads to the flammable mixture > HARMONISED EUROPEAN ATEX STANDARD The European Union has adopted two harmonized directives in the field of health and safety. The directives are known as ATEX 00a and ATEX 37. Directive ATEX 00a (94/9/EC) lays down minimum safety requirements for products intended for use in potentially explosive atmospheres in European Union member states. Directive ATEX 37 (99/92/EC) defines minimum requirements for health and safety at the workplace, for working conditions and for the handling of products and materials in potentially explosive atmospheres. This directive divides the workplace into zones and defines criteria by which products are categorized within these zones. ATEX ATEX 94/9/EC (ATEX 00a) ATEX 99/92/EC (ATEX 37) EX Products directive Covers manufacturers health and safety requirements Workers directive Covers and users minimum requirements for health and safety protection of workers ATEX 00a Product directive ATEX 37 Workers directive Products requirements Product test Quality audit Certificates documentation instructions Risks analysis Zones identification Assessment Explosion protection document DIRECTIVE 94/9/EC OF THE EUROPEAN PARLIAMENT AND THE COUNCIL dated 23 March 994 on the approximation of the laws of the Member States concerning equipment and protective systems intended for use in potentially explosive atmospheres Applied to equipment and protective systems intended for use in potentially explosive atmospheres. Covers all risk of explosion (not only those from electrical origin). Covers both application for mines and for other application. Applied to equipment, components, safety devices, controlling devices and regulating devices. DIRECTIVE 999/92/EC OF THE EUROPEAN EX PARLIAMENT AND OF THE COUNCIL dated 6 December 999 on minimum requirements to improve the safety and health protection of workers potentially at risk of explosive atmospheres (5 th individual Directive within the meaning of Article 6() of Directive 89/39/EEC) Gives the minimum requirements in the field of safety and health protection of workers potentially at risk of explosive atmospheres. Define obligations of the employer. Defines Zones and criteria for selection of equipment and protective systems. 2

3 > GROUP AND EQUIPMENT CATEGORY GROUP I Mines and surface installations of such mines > GROUP II ZONES CATEGORY M Very high level of protection CATEGORY M2 High level of protection GROUP II Other places CATEGORY Very high level of protection CATEGORY 2 High level of protection CATEGORY 3 Normal level of protection EX Certification GAS 0 2 DUST Frequency and duration of the occurrence of an explosive atmosphere Continuously present or for long periods or frequently Occasionally Not likely to occur > POTENTIALLY EXPLOSIVE ATMOSPHERES For an explosive atmosphere to form, the flammable material must be present in a certain concentration. If the concentration is too low (lean mixture) or too high (rich mixture), no explosion occurs, rather there is just a slow combustion reaction or none at all. It is only in the range between the lower and upper explosion limit that the mixture reacts explosively when ignited. The explosion limits depend on the ambient pressure and the proportion of oxygen in the air. AIRFIRE FUEL HEAT > GROUP II CATEGORIES ZONES CATEGORY GAS DUST Frequency and duration of the occurrence of an explosive atmosphere Level of protection 0 20 Continuously present or for long periods or frequently Very high 2 means of protection 2 faults 2 2 Occasionally High mean of protection fault Not likely to occur Normal Guaranted in normal operation > CONFORMITY ASSESSMENT PROCEDURES CATEGORY / M 2 / M2 2 / M2 3 TYPE OF PRODUCTS All Electric Notelectric All PROCEDURE CE typeexamination (Annex III) Production quality assurance (Annex IV) or product verification (Annex V) CE typeexamination (Annex III) Conformity to type referred (Annex VI) or Product quality assurance (Annex VII) Internal control of production (Annex VIII) and communicate the dossier to a notified body Internal control of production (Annex VIII) 3

4 Index ZENITH Series Increased Safety Enclosures and Terminal Boxes page 006 STAINLESS STEEL ENCLOSURES Series Stainless steel enclosures page 009 CONTROL BOXES Series Control Command units page 00 4

5 Index ALUBOX EX Series Junction boxes in IP66 aluminium alloy page 02 ISOLATORS Series High current Switchdisconnectors page 022 ADVANCE GRP System Switched interlocked socket outlets and related plugs page 024 5

6 ZENITH P Series > RANGE AND ACCESSORIES ZONE, 2, 2, 22 ENCLOSURE EARTH CONTINUITY PLATE A H W A A A A A A A A A A A A A A A0390 > ACCESSORIES A) Earth Continuity Plate (ECP) made of zinc plated steel. Also available in brass or copper. B) Component Mounting Plate made of zinc plated steel. C) External Mounting Brackets (4 sets) made of stainless steel AISI 36. D) External Mounting Vertical Feet (2 sets) made of stainless steel AISI 36. E) Earth Stud made of brass. Also available in stainless steel AISI 36 (*). F) External Hinges (2 sets) made of termoplastic material (*). (*) maching is required. The enclosure can be machined and drilled on request gland holes from M6 to M40. Terminal box with Glands Empty Enclosure Terminal Box Predrilled Enclosure 6

7 INTERNAL MOUNTING EXTERNAL MOUNTING EXTERNAL MOUNTING PLATE BRACKETS VERTICAL FEET EARTH STUD (*) EXTERNAL HINGES (*) B C D E 644.B B0 644.B C D B B B C D E F B B C D B B90 ZENITH P Series > FINISHING SERVICE Scame can supply these enclosures as empty components or after performing the following operations: drilling entries; tapping holes; fitting terminals; supplying suitable cable glands. Terminal Box Assembly Drawing FIT Exe NYLON CABLE GLANDS TO ALL ENTRIES BOTTOM SIDE VIEW WITH LID REMOVED RIGHT SIDE LEFT SIDE TOP SIDE COMPONENT S DETAIL: Fixing device for terminals, 2 pcs 2 Terminals 8 pcs x 2.5mm 3 Earth terminals, 4 pcs x 2.5mm CABLE GLANDS M25, 2 pcs M20, 4 pcs Enclosure + ECP Enclosure + Internal Plate Terminal Box without Glands 7

8 ZENITH P Series > APPROVED ATEX CERTIFIED TERMINALS Terminals shall be selected from this list of approved manufacturers. Additional manufacturers are available on request after approval of our internal laboratory. Terminal blocks (internal plate mounted) and mini terminals (DIN rail TS5) are suitable for use with small size enclosures. Standard rail terminals (DIN rail TS35) are suitable for use with large size enclosures. When the enclosure is supplied as Ex i (low voltage instrumentation application), a suitable set of blue terminals is supplied. Terminals can be screw type or spring cage. Cross section is from.5 mm 2 to 35 mm 2. Weidmuller Terminal Block BK, MK Mini Terminal AKZ Terminal Type: WDU, ZDU, SAK, SAK K. Wago Terminal Block 262, 264 Terminal Type: 280, 28, 282, 283, 284 and 2002, 2004, 2006, 200, 206. Phoenix Terminal Type: UT, ST, DT, UK. ABB entrelec Terminal M../.. EX. Cabur Terminal Block BPL, TPL Mini Terminal RN Terminal CBD. EX e Ex i Terminals EX e Terminal Blocks > DIN METALLIC RAILS Steel, cold lamination Electrolytic zinc coating Thickness of zinc coating: 8 micron min. Length of the rail: 2m Non drilled rail with drilling points provided Drilled rail with slots > TYPE Ω TS 35 Reference standard: CEI EN 6075 Dimensions (mm) 35x7,5x Description Plain DIN rail 40m Slotted DIN rail (8x6,3 25) 40m > TYPE Ω TS 5 Reference standard: CEI EN6075 Dimensions (mm) 5x5,5x Description Plain DIN rail 00m Slotted DIN rail (2,2x4,2 20) 00m Pack Quantity. Terminal Box with Glands Terminal Box 8

9 STAINLESS STEEL ENCLOSURES Series > STAINLESS STEEL ENCLOSURES ZONE, 2, 2, 22 Dimension (mm) A B V Screws XN XN XN XN XN XN XN XN XN XN XN XN XN XN XN XN XN XN XN XN XN XN XN XN XN XN XN XN XN XN XN XN XN XN XN XN XN XN80409 Dimension (mm) A B V Screws XN5509p XN20509p XN202009p XN30509p XN302009p XN303009p XN304009p XN402009p XN403009p XN404009p XN405609p XN564009p XN30205p XN30305p XN30405p XN33205p XN33305p XN36205p XN36305p XN40205p XN40305p XN40405p XN40565p XN50305p XN50405p XN56405p XN30409p XN33209p XN33309p XN36209p XN36309p XN40309p XN40409p XN40569p * 59.XN40809p XN50309p XN50409p * 59.XN80409p STAINLESS STEEL ENCLOSURES Series Note: Locking mechanism used. For boxes type XN80...(p) a XN..80..(p) the girdles are fastened by four M8 screws (DIN 92) into M8 welded nuts with locking thread. 9

10 CONTROL BOXES Series > CENTRAL STOP BUTTON ZONE, 2, 2, 22 Contacts Weight (Kg) with protective glass cap emergency stop emergency switching off,36 59.V00 0,89 59.V006/ES 59.V006/ESO,36 59.V002 0,89 59.V007/ES 59.V007/ESO,39 59.V003 0,92 59.V008/ES 59.V008/ESO,39 59.V004 0,92 59.V009/ES 59.V009/ESO,39 59.V005 0,92 59.V00/ES 59.V00/ESO > INDICATOR LIGHT ZONE, 2, 2, 22 Nominal Voltage Weight (Kg) 230 V 50 Hz 0,85 59.V02/ 20 V 50Hz 0,85 59.V022/ 48 V AC/DC 0,85 59.V023/ 24 V AC/DC 0,85 59.V024/ 2 V AC/DC 0,85 59.V025/ 6 V AC/DC 0,85 59.V026/ See colour table 0 below and complete with the letter relevant to the choosen colour. Colour table 0: Green Transparent Red Yellow Blue B T R Y BE 0

11 > SPRINGLOADED PUSHBUTTON ZONE, 2, 2, 22 Contacts Weight (Kg) 0,85 59.V0/ 0,85 59.V02/ 0,88 59.V03/ CONTROL BOXES Series 0,88 59.V04/ 0,88 59.V05/ See colour table 02 below and complete with the letter relevant to the choosen colour. > DOUBLE PUSHBUTTON ZONE, 2, 2, 22 Contacts SB SB2 Weight (Kg) 0,90 59.V06/ / 59.V07/ / 0,90 59.V08/ / 0,90 59.V09/ / 0,96 59.V020/ / See colour table 02 below and complete with the letter relevant to the choosen colour for the upper push button. See colour table 02 below and complete with the letter relevant to the choosen colour for the bottom push button. Colour table 02: Black Green White Red Yellow B G W R Y

12 CONTROL BOXES Series > PUSHBUTTON / INDICATOR ZONE, 2, 2, 22 Nominal Voltage Weight (Kg) 230 V 50 Hz 0,90 59.V40/ / 24 V AC/DC 0,90 59.V4/ / See colour table 02 below and complete with the letter relevant to the choosen colour for the upper push button. See colour table 02 below and complete with the letter relevant to the choosen colour for the bottom push button. > POSITION SWITCH / INDICATOR ZONE, 2, 2, 22 Nominal Voltage Weight (Kg) 230 V 50 Hz 0,9 59.V30/ / 24 V AC/DC 0,9 59.V3/ / See colour table 02 below and complete with the letter relevant to the choosen colour for the upper push button. See colour table 02 below and complete with the letter relevant to the choosen colour for the bottom push button. Colour table 02: Black Green White Red Yellow B G W R Y 2

13 > POSITION SWITCHES ZONE, 2, 2, 22 Contacts Description Weight (Kg) 2 pole switch Coupling type 0,86 59.V027 4 pole switch Coupling type 2 0,88 59.V028 CONTROL BOXES Series Variation switch Coupling type 6 0,89 59.V029 Switch with 3 position 0,89 59.V030 Switch with 3 positions for control of relays Self return from START to STOP position 0,86 59.V03 > LOCKING SWITCH / SERIES SWITCH ZONE, 2, 2, 22 Contacts Weight (Kg) Locking switch Switch coupling 5 0 0,88 59.V032 (*) SA SA2 0,9 59.V033 (*) Locking in different positions, padlocks or mushroom heads on request. 3

14 CONTROL BOXES Series > DOUBLE PUSHBUTTON / INDICATOR ZONE, 2, 2, 22 Indicator HL green colour Button colour Weight (Kg) 230V 50Hz right (SB2) green left (SB) white 0,98 59.V0 230V 50Hz right (SB2) green left (SB) red 0,98 59.V02 24V AC/DC right (SB2) green left (SB) white 0,98 59.V03 24V AC/DC right (SB2) green left (SB) red 0,90 59.V04 > TRIPLE PUSHBUTTON ZONE, 2, 2, 22 Button colour Weight (Kg) SB, SB2 green SB3 white 0,98 59.V05 SB, SB2 green SB3 red 0,98 59.V06 B, SB2 black SB3 red 0,98 59.V07 B, SB2 black SB3 black 0,98 59.V08 > DOUBLE PUSHBUTTON / POSITION SWITCH ZONE, 2, 2, 22 Weight (Kg),02 59.V20/ / See colour table 02 below and complete with the letter relevant to the choosen colour for the upper push button. See colour table 02 below and complete with the letter relevant to the choosen colour for the bottom push button. Colour table 02: Black Green White Red Yellow B G W R Y 4

15 > EX POTENTIOMETER ZONE, 2, 2, 22 Potentiometer Values KΩ,00 59.RP k 2 KΩ,00 59.RP 2k 5 KΩ,00 59.RP 5k 0 KΩ,00 59.RP 0k > INDIRECT AMMETER ZONE, 2, 2, 22 Weight (Kg) CONTROL BOXES Series Range 00/30,00 59.PAA/0 59.PA5A/0 05/45,00 59.PAA/5 59.PA5A/5 020/60,00 59.PAA/20 59.PA5A/20 030/90,00 59.PAA/30 59.PA5A/30 040/20,00 59.PAA/40 59.PA5A/40 050/50,00 59.PAA/50 59.PA5A/50 060/80,00 59.PAA/60 59.PA5A/60 075/225,00 59.PAA/75 59.PA5A/75 000/300,00 59.PAA/00 59.PA5A/00 050/450,00 59.PAA/50 59.PA5A/ /600,00 59.PAA/ PA5A/200 Note: different ranges on request. Weight (Kg) In/A In/5A 5

16 CONTROL BOXES Series > CONTROL BOX V202 ZONE, 2, 2, 22 Description Polyester control box 59.V202 Polyester control box (24V indicator) 59.V202/24 > CONTROL BOX V203 ZONE, 2, 2, 22 Description Polyester control box 59.V203 Polyester control box (24V indicator) 59.V203/24 > CONTROL BOX V202 > CONTROL BOX V203 6

17 > CONTROL BOX V204 ZONE, 2, 2, 22 Description Polyester control box 59.V204 > CONTROL BOX V205 ZONE, 2, 2, 22 CONTROL BOXES Series Description Polyester control box 59.V205 > CONTROL BOX V204 > CONTROL BOX V205 COVER CASE 7

18 CONTROL BOXES Series > CONTROL BOX V206 ZONE, 2, 2, 22 Description Polyester control box 59.V206 Polyester control box (24V indicator) 59.V206/24 > CONTROL BOX V207 ZONE, 2, 2, 22 Description Polyester control box 59.V207 Polyester control box (24V indicator) 59.V207/24 > CONTROL BOX V206 > CONTROL BOX V207 8

19 > CONTROL BOX V23 ZONE, 2, 2, 22 Description Polyester control box 59.V23 Polyester control box (24V indicator) 59.V23/24 > CONTROL BOX V25 ZONE, 2, 2, 22 CONTROL BOXES Series Description Polyester control box 59.V25 > CONTROL BOX V23 > CONTROL BOX V25 COVER CASE 9

20 CONTROL BOXES Series > CONTROL BOX V26 ZONE, 2, 2, 22 Description Polyester control box 59.V26 Polyester control box (24V indicator) 59.V26/24 > CONTROL BOX V27 ZONE, 2, 2, 22 Description Polyester control box 59.V27 Polyester control box (24V indicator) 59.V27/24 > CONTROL BOX V26 > CONTROL BOX V27 20

21 ALUBOX Series AL > ENCLOSURES IP66 ZONE 2, 22 (*) Dimensions (mm) Screw for Earthing attaching cover screws Weight (Kg) 00 x 00 x 59 n 2 M5x0mm n M4x6 0,290 / x 5 x 60 n 4 M5x6mm n M4x6 0,390 / x 42 x 64 n 4 M5x6mm n M4x6 0,64 / x 68 x 80 n 4 M5x6mm n M4x6 0,920 / x 27 x 93 n 4 M6x20mm n M4x6,430 / x 264 x 22 n 4 M6x20mm n M4x6 2,236 / x 35 x 53 n 4 M6x20mm n M4x6 3, (*) ZONE 2 under development. Enclosure and cover in diecast aluminium. Externally varnished. Pack Quantity. With stainless steel screws for attaching cover and selftapping zinccoated steel screws for earthing the enclosure and cover. = Countersunk head screw. = Flat head screw. > MOUNTING PLATES For enclosures (mm) ALUBOX Series ALUBOXEX Series > DIN RAIL KIT Screw for Thickness Weight attaching cover (mm) (Kg) 00 x 00 x x 5 x 60 n 4 M4x6,5 0,40 / x 42 x 64 n 4 M4x6,5 0,23 / x 68 x 80 n 4 M4x6,5 0,245 / x 27 x 93 n 4 M4x6,5 0,423 / x 264 x 22 n 4 M4x6,5 0,626 / x 35 x 53 n 4 M4x6 2, Zinccoated steel plate. With zinccoated steel selftapping screws for attaching the plate. Enclosures and covers in aluminium alloy with blank walls and covered. Pack Quantity. Holding seal in expanded EPDM, already mounted in place on the cover. Fixing to wall by brackets incorporated in the enclosure base. 2

22 ISOLATORS Series > SURFACE MOUNTING METAL VERSION ZONE 22 (*) Poles Enclosure dimensions (mm) Protection degree Emergency Switching General use Emergency Switching General use HEM HGE A 3 05x50x82 IP65 /2 590.HEM HGE HEM HGE HEM HGE A 3 05x50x82 IP65 /2 590.HEM HGE HEM HGE HEM HGE A 3 05x50x82 IP65 /2 590.HEM HGE HEM HGE HEM HGE A 3 50x20x06 IP65 /5 590.HEM HGE6303 (*) ZONE, 2, 2 under development. Pack Quantity HEM HGE

23 > SURFACE MOUNTING PLASTIC VERSION ZONE 22 (*) Poles Entry General use Emergency switching 2 /2 590.XGE XEM A 3 2xM25 + xm20 /2 590.XGE XEM /2 590.XGE XEM /2 590.XGE XEM A 3 2xM32 + xm20 /2 590.XGE XEM /2 590.XGE XEM /2 590.XGE XEM A 3 2xM32 + xm20 /2 590.XGE XEM4003 (*) ZONE, 2, 2 under development. Pack Quantity. 4 /2 590.XGE XEM4004 ISOLATORS Series 23

24 ADVANCE GRP System > MECHANICALLY INTERLOCKED SOCKET OUTLETS WITH IDevice 6A32A63A IP66 VOLTAGE >50V ZONE 22 (*) Description Socket Hz Volt Colour h 6A 32A 63A Switchdisconnector 2P+E 3P+E 3P+N+E 50/60 50/60 50/ V 38045V 34645V Description Socket Hz Volt Colour h 6A 32A 63A Switchdisconnector and fuse (**) 2P+E 3P+E 3P+N+E 50/60 50/60 50/ V 38045V 34645V F F F F F F F F F (*) ZONE, 2, 2 under development. (**) Fuses not included. Pack Quantity. > WITH FUSE HOLDER IP66 VOLTAGE <50V ZONE 22 (*) Description Socket Colour Rated voltage With transformer (**) 2P6A 2025V~ (*) ZONE, 2, 2 under development. (**) SELV transformer g 220/24V~ 50VA. Pack Quantity F EX batteries can be produced by request with special order.

25 > ACCESSORIES AND COMPLEMENTARY PRODUCTS Description Microswitch kit for Advance GRP 6A32A63A for pluginserted control Contacts NO/NC Max kit for 6A32A sockets; Max 2 kit for 63A sockets. > AUXILIARY CONTACTS / ADVANCE GRP System Description NC contact NO contact NC= normally closed. NO= normally open. For switches 6A32A PL A PL A32A PL A PL Pack Quantity. > COMPLEMENTARY PRODUCTS OPTIMA EX SERIES PLUGS 6A32A63A IP66/IP67 Description Poles Hz Volt Colour h 6A 32A 63A Plugs 2P+E 50/ V 6 28.EX EX EX6333 3P+E 50/ V 6 28.EX EX EX3236 3P+N+E 50/ V 6 28.EX EX EX6337 Description Poles Hz Volt Colour h Plug 2P 50/ EX600 Pack Quantity. 25

26 ADVANCE GRP System > MECHANICALLY INTERLOCKED IDevice SOCKET OUTLETS 25A IP66 ZONE 22 (*) Description Plug Hz Volt Colour h 2P+E 25A 50/ V P+E 25A 50/ V P+N+E 25A 50/ V Description Plug Hz Volt Colour h Switchdisconnector Switchdisconnector and fuse (**) 2P+E 25A 50/ V F 3P+E 25A 50/ V F 3P+N+E 25A 50/ V F Description Plug Hz Volt Colour h Fuse (**) and switchdisconnector 2P+E 25A 50/ V FS 3P+E 25A 50/ V FS 3P+N+E 25A 50/ V FS Description Molded case circuit breaker with thermal magnetic trip unit Plug Hz Volt Colour h 2P+E 25A 50/ V M 3P+E 25A 50/ V M 3P+N+E 25A 50/ V M 26 Description Molded case circuit breaker with thermal magnetic and residual current release trip units Plug Hz Volt Colour h 2P+E 25A 50/ V RM 3P+E 25A 50/ V RM 3P+N+E 25A 50/ V RM (*) ZONE, 2, 2 under development. (**) Fuses not included Pack Quantity.

27 > ELECTRICALLY INTERLOCKED SOCKET OUTLETS IP66 ZONE 22 (*) Description Contactor (**) Plug 2P+E 25A 50/ V T 3P+E 25A 50/ V T 3P+N+E 25A 50/ V T (*) ZONE, 2, 2 under development. (**) Microswitch already provided. Contactor operated by microswitch. Hz Volt Colour h Pack Quantity. ADVANCE GRP System > ACCESSORIES Description Contacts Terminals Microswitch kit 400V 0A (microswitch + terminal block) Max 2 kit. NO+NC 4x4 mm For products with mechanical interlock. > COMPLEMENTARY PRODUCTS OPTIMAEX SERIES PLUGS 25A IP66/IP67 Description Plugs Pack Quantity. Hz Volt Colour h 2P+E 25A 50/ V 6 28.EX2533 3P+E 25A 50/ V 6 28.EX2536 3P+N+E 25A 50/ V 6 28.EX

28 EX PRODUCTS TECHNICAL SHEETS

29 Index ZENITH Series Increased Safety Enclosures and Terminal Boxes STAINLESS STEEL ENCLOSURES Series Stainless steel enclosures PAGE 03 PAGE 035 CONTROL BOXES Series Control command units ALUBOX EX Series Junction boxes in IP66 aluminium alloy PAGE 036 PAGE 042 ISOLATORS Series High current Switchdisconnectors ADVANCE GRP System Switched interlocked socket outlets and related plugs PAGE 044 PAGE

30 ZENITH P Series > INCREASED SAFETY ENCLOSURES AND TERMINAL BOXES > REFERENCE STANDARDS IEC / EN Electrical apparatus for explosive gas atmospheres. IEC 6240 / EN 6240 Electrical apparatus for use in the presence of combustible dust. IEC /EN Electrical apparatus for explosive gas atmospheres. Part 7: increased safety e. ZENITH P Series The ZENITH P increased safety enclosure range meets the requirements of IEC/EN , , (Zone and 2) or those of IEC/EN 6240, 624 (Zone 2 and 22). They are developed, manufactured and tested in accordance with stateoftheart engineering practice and ISO 900 and ISO > GENERAL DESCRIPTION The ZENITH P range comprises 5 sizes of enclosure manufactured in GRP glass reinforced polyester with 4 mm thickness. Polyester gives excellent mechanical strength and life expectancy: this material is highly resistant to contamination, it is absolutely corrosionproof and is suitable for LSOH (low smoke zero halogen) applications. The range is carbon loaded which helps to reduce the surface resistance of the material and consequently removes the risk of ignition sources through static induced sparking resistivity. The mounting holes are contained within the profile of the enclosure, but are outside the seal. The wall thickness is sufficient to allow entry holes to be machined in the walls of the enclosure and it provides a very good alternative to aluminium, stainless steel or cast iron. > APPLICATION These enclosures may be supplied with terminals fitted or as an empty certified component. If supplied as the latter, then final certification by the customer after fitting additional equipment, must be obtained. The ZENITH P range offers safe protection in various applications including both industrial and hazardous area where extremely unfavourable conditions are present. They are ideal for a wide variety of uses such as OEM applications, fire protection systems, tunnel wiring, lighting, power and instrument junction boxes. > CERTIFICATIONS The products have passed laboratory tests and obtained the safety certification by approved ATEX certification bodies. Scame guarantees that the enclosure systems have been correctly manufactured and are compliant with safety standards. The correct use of the enclosure systems for their intended duty is essential for safeguarding the type of protection. > SPECIFICATIONS Atex Code: Ex Protection type: II 2GD Ex e II Ex ia IIC Ex td A2 IP6X T80 C (Ta 50 C +40 C) Certificates: Empty Enclosure Sira 08ATEX304IU IECEx SIR U Terminal Box Sira 08ATEX3042 IECEx SIR Operating Temperature Range: 60 C to +75 C (limits) Temperature Class and Ambient Standard Ambient 40 C and T6 Class Optional Ambient 60 C and T6 Class Ambient 60 C and T5 Class Ambient 75 C and T4 Class Degree of Protection: IP66 Material: Glass Reinforced Polyester (SMC) 4 mm thickness Carbon Loaded for AntiStatic protection UV resistant according to ISO Halogen Free and formulated RoHs directive Absolutely corrosionproof Seawaterproof Surface Resistance: Antistatic properties: < 0 9 Ω The enclosures do not present a hazard from static electricity Finish: Natural Black RAL 9005 Impact Resistance: The enclosures are designed to withstand an impact of 7 J, and to be used in normal conditions of vibration 3

31 ZENITH P Series > ZENITH P SERIES External Internal Fixings Weight Code Enclosure size H W D h w d H+ W+ Holes Weight x80x55 75x80x75 75x0x55 75x0x75 75x60x55 75x60x75 75x90x55 75x90x75 75x230x55 75x230x75 20x220x90 60x60x90 60x260x90 60x360x90 60x560x Ø 4,5 Ø 4,5 Ø 4,5 Ø 4,5 Ø 4,5 Ø 4,5 Ø 4,5 Ø 4,5 Ø 4,5 Ø 4,5 Ø 6,5 Ø 6,5 Ø 6,5 Ø 6,5 Ø 6, FRONT AND SECTION > LID FIXING SCREWS SIDE Corrosion resistant Stainless Steel (complete with retaining washer) for flat blade and PH screw head driver. Mounting holes located outside of the sealed area. H + (fixing centres) W + (fixing centres) > WEATHERPROOF > CERTIFICATION LABEL Lid gasket made of silicone rubber, moulded in one piece. Optimum performance at low and high temperature extremes. Certified self adhesive label. Stainless steel bonded plate (on request). > INCLUDED IN DELIVERY > TERMINAL MOUNTING Empty Enclosure: Enclosure with silicone seal and accessories not assembled. Terminal Box: Predrilled Enclosure system depending on version either with DIN rails and accessories and terminals (assembled). Cable glands can be supplied on request. Terminals shall be rail or internal plate mounted. DIN rail (TS 5, TS 35): row. Certified terminal manufacturer and type have cross section.5mm 2 to 35mm 2. Our assembly service can supply these enclosures preassembled with terminals and cable glands according to customer s requirements. 32

32 > MAXIMUM PERMITTED POWER DISSIPATION Code Enclosure size 75x80x55 75x80x75 75x0x75 75x0x75 75x60x55 75x60x75 75x90x55 75x90x75 75x230x55 75x230x75 20x220x90 60x60x90 60x260x90 60x360x90 60x560x90 Ambient 40 C T6 class ( ) ( ) Ambient 60 C T6 class ( ) ( ) Ambient 60 C T5 class ( ) ( ) NA NA NA NA Ambient 75 C T4 class ( ) ( ) NA NA NA NA Terminal Box Terminal Box ZENITH P Series ( ) = for cage type terminals ( ) = for screw type terminals > MAXIMUM NUMBER OF TERMINALS PHYSICAL DIMENSIONS Code Enclosure size Term. Block Mini 2.5mm 2 2.5mm 2 4mm 2 75x80x55 75x80x75 75x0x75 75x0x75 75x60x55 75x60x75 75x90x55 75x90x75 75x230x55 75x230x75 20x220x90 60x60x90 60x260x90 60x360x90 60x560x mm 2 0mm 2 6mm 2 35mm 2 The quantity of applicable terminals can be fitted in the enclosure is dependant on the internal width. The number may need to be reduced, depending on the actual current flowing in the conductors. In case the power dissipation of the terminals is superior to the maximum permitted power here stated, a different enclosure must be chosen or the temperature class must be changed Enclosure Terminal Box 33

33 ZENITH P Series > STANDARD ENTRY ARRANGEMENTS Code Enclosure size 75x80x55 75x80x75 75x0x55 75x0x75 75x60x55 75x60x75 75x90x55 75x90x75 75x230x55 75x230x x220x x60x x260x x360x x560x90 Top/Bottom Sides A/C Left/Right Sides B/D Rear Side F M6 M20 M25 M32 M40 M6 M20 M25 M32 M6 M M > DRILLING ENVELOPE Code Enclosure size Top/Bottom sides A/C WxD Left/Right sides B/D H2xD2 Rear side F H3xW x80x55 48x34 28x28 60x x80x75 48x54 27x48 60x x0x55 80x34 28x28 60x x0x75 80x54 27x48 60x x60x55 30x34 28x28 60x x60x75 30x54 27x48 60x x90x55 60x34 28x28 60x60 Cable gland size A (mm) Clearance B (mm) Gland Clearance x90x75 75x230x55 75x230x75 20x220x90 60x60x90 60x260x90 60x360x90 60x560x90 60x54 90x34(x2) 90x54(x2) 80x58 0x65 20x65 30x65 240x65(x2) 27x48 28x28 27x48 60x52 84x56 84x56 84x56 84x56 60x60 60x90 60x90 05x80 40x0 40x20 40x30 40x240(x2) > CABLE GLAND FROM CEAG Screw plugs, blanking plugs, cable glands for Exi, cable glands for Exe. 34

34 STAINLESS STEEL ENCLOSURES Series > STAINLESS STEEL ENCLOSURES > REFERENCE STANDARDS > VERSIONS Installation boxes IEC / EN Electrical apparatus for explosive gas atmospheres. IEC 6240 / EN 6240 Electrical apparatus for use in the presence of combustible dust. IEC /EN Electrical apparatus for explosive gas atmospheres. Part 7: increased safety e. > TECHNICAL CHARACTERISTICS Type of protection: Ambient temperature ranges: I M2/II 2GD Ex e td I/II IP66 SILICONACETATE seal: 60 C to +5 C SILICON seal: 60 C to +5 C POLYURETHANE seal: 40 C to +70 C STAINLESS STEEL ENCLOSURES Series 35

35 CONTROL BOXES Series > CONTROL BOXES > REFERENCE STANDARDS IEC / EN Electrical apparatus for explosive gas atmospheres. IEC 6240 / EN 6240 Electrical apparatus for use in the presence of combustible dust. IEC /EN Electrical apparatus for explosive gas atmospheres. Part 7: increased safety e. > VERSIONS > TECHNICAL CHARACTERISTICS Central stop button with protective glass cap Central stop button standard Springloaded pushbutton Central stop button standard/with protective glass cap Type of protection: II 2GD Ex de td IIC T85 C T6 IP65 Material, box dimensions: Polyester, (wxhxd) 22x20x90mm Cable gland: M20 (Ø7 Ø2)mm Terminals: max. 2x2,5mm 2 Standardhead: Latching, turn to release Standardtext: Central Stop Other types of heads, contacts or text on request. Springloaded pushbutton Type of protection: Material, box dimensions: Cable gland: II 2GD Ex de td IIC T6 T85 C IP65 Polyester, (wxhxd) 22x20x90mm M20 (Ø7 Ø2)mm Terminals: max. 2x2,5mm 2 Different contact blocks on request. 36

36 > CONTROL BOXES > REFERENCE STANDARDS IEC / EN Electrical apparatus for explosive gas atmospheres. IEC 6240 / EN 6240 Electrical apparatus for use in the presence of combustible dust. IEC /EN Electrical apparatus for explosive gas atmospheres. Part 7: increased safety e. CONTROL BOXES Series > VERSIONS > VERSIONS VERSION : Double pushbutton VERSION 2: Indicator light VERSION 3: Pushbutton / indicator VERSION 4: Position switch / indicator VERSION 5: Position switches VERSION 6: Locking switch / Series switch Double pushbutton / indicator > TECHNICAL CHARACTERISTICS Double pushbutton Type of protection: II 2GD Ex de td IIC T6 T85 C IP65 Material, box dimensions: Polyester (wxhxd) 22x20x90mm Cable glands: M20 (Ø7 Ø2)mm Terminals: max. 2x2,5mm 2 Indicator light Type of protection: II 2GD Ex emb td II T6 T85 C IP65 Material, box dimensions: Polyester (wxhxd) 22x20x90mm Cable gland: M20 (Ø7 Ø2)mm Terminals: max. 2x2,5mm 2 Pushbutton / indicator Type of protection: II 2GD Ex demb td IIC T6 IP65 Material, box dimensions: Polyester (wxhxd) 22x20x90mm Cable gland: M20 (Ø7 Ø2)mm Terminals: max. 2x2,5mm 2 > TECHNICAL CHARACTERISTICS Position switch / indicator Type of protection: II 2GD Ex demb td IIC T6 IP65 Material, box dimensions: Polyester (wxhxd) 22x20x90mm Cable gland: M20 (Ø7 Ø2)mm Terminals: max. 2x2,5mm 2 Position switches Type of protection: II 2GD Ex de td IIC T6 T85 C IP65 Material, box dimensions: Polyester (wxhxd) 22x20x90mm Cable gland: M20 (Ø7 Ø2)mm Terminals: max. 2x2,5mm 2 Locking switch / Series switch Type of protection: II 2GD Ex de td IIC T6 T85 C IP65 Material, box dimensions: Polyester (wxhxd) 22x20x90mm Cable gland: M20 (Ø7 Ø2)mm Terminals: max. 2x2,5mm 2 Double pushbutton / indicator Type of protection: II 2GD Ex demb td IIC T6 T85 C IP65 Material, box dimensions: Polyester (wxhxd) 22x20x90mm Cable gland: M20 (Ø7 Ø2)mm Terminals: max. 2x2,5mm 2 37

37 CONTROL BOXES Series > CONTROL BOXES > REFERENCE STANDARDS IEC / EN Electrical apparatus for explosive gas atmospheres. IEC 6240 / EN 6240 Electrical apparatus for use in the presence of combustible dust. IEC /EN Electrical apparatus for explosive gas atmospheres. Part 7: increased safety e. > VERSIONS > TECHNICAL CHARACTERISTICS VERSION : Triple pushbutton VERSION 2: Double pushbutton / position switch EX potentiometer Triple pushbutton Type of protection: II 2GD Ex de td IIC T6 T85 C IP65 Material, box dimensions: Polyester, (wxhxd) 22x20x90mm Cable gland: M20 (Ø7 Ø2)mm Terminals: max. 2x2,5mm 2 Double pushbutton / position switch Indirect AMMeter Type of protection: II 2GD Ex de td IIC T6 IP65 Material, box dimensions: Polyester, (wxhxd) 22x20x90mm Cable gland: M20 (Ø7 Ø2)mm Terminals: max. 2x2,5mm 2 EX potentiometer Type of protection: II 2GD Ex demb td IIC T6 T85 C IP65 Material, box dimensions: Polyester, (wxhxd) 22x20x90mm Cable gland: M20 (Ø7 Ø2)mm Terminals: max. 2x2,5mm 2 Indirect AMMeter Type of protection: II 2GD Ex emb td IIC T6 T85 C Material, box dimensions: Polyester, (wxhxd) 22x20x90mm Cable gland: M20 (Ø7 Ø2)mm Terminals: max. 2x2,5mm 2 38

38 > CONTROL BOXES > REFERENCE STANDARDS IEC / EN Electrical apparatus for explosive gas atmospheres. IEC 6240 / EN 6240 Electrical apparatus for use in the presence of combustible dust. IEC /EN Electrical apparatus for explosive gas atmospheres. Part 7: increased safety e. CONTROL BOXES Series > TECHNICAL CHARACTERISTICS 59.V202 > TECHNICAL CHARACTERISTICS 59.V203 Type of protection: II 2GD Ex demb td IIC T6 T85 C IP65 Type of protection: II 2GD Ex demb td IIC T6 T85 C IP65 Cable gland (bottom): pc M25 (Ø8 Ø7)mm Cable gland (bottom): pc M25 (Ø8 Ø7)mm Dimensions (wxhxd): 20x220x90mm Dimensions (wxhxd): 20x220x90mm Weight:,38kg Weight:,39kg 59.V V203 39

39 CONTROL BOXES Series > TECHNICAL CHARACTERISTICS 59.V204 > TECHNICAL CHARACTERISTICS 59.V205 Type of protection: II 2GD Ex demb td IIC T6 T85 C IP65 Type of protection: II 2GD Ex demb td IIC T6 T85 C IP65 Cable gland (bottom): pc M25 (Ø8 Ø7)mm Cable gland (bottom): pc M25 (Ø8 Ø7)mm Dimensions (wxhxd): 20x220x90mm Dimensions (wxhxd): 20x220x90mm Weight:,50kg Weight:,55kg 59.V V205 COVER CASE > TECHNICAL CHARACTERISTICS 59.V206 > TECHNICAL CHARACTERISTICS 59.V207 Type of protection: II 2GD Ex demb td IIC T6 T85 C IP65 Type of protection: II 2GD Ex edm td IIC T6 T85 C IP65 Cable gland (bottom): pc M25 (Ø8 Ø7)mm Cable gland (bottom): pc M25 (Ø8 Ø7)mm Dimensions (wxhxd): 20x220x90mm Dimensions (wxhxd): 20x220x90mm Weight:,5kg Weight:,44kg 59.V V207 40

40 > TECHNICAL CHARACTERISTICS > TECHNICAL CHARACTERISTICS Type of protection: Cable gland (bottom): Dimensions (wxhxd): Weight: II 2GD Ex demb td IIC T6 T85 C IP65 pc M25 (Ø8 Ø7)mm 20x220x90mm,36kg Type of protection: Cable gland (bottom): Dimensions (wxhxd): Weight: 59.V23 59.V25 II 2GD Ex demb td IIC T6 T85 C IP65 pc M25 (Ø8 Ø7)mm 20x220x90mm,52kg CONTROL BOXES Series COVER CASE > TECHNICAL CHARACTERISTICS > TECHNICAL CHARACTERISTICS Type of protection: II 2GD Ex demb td IIC T6 T85 C IP65 Type of protection: II 2GD Ex demb td IIC T6 T85 C IP65 Cable gland (bottom): pc M25 (Ø8 Ø7)mm Cable gland (bottom): pc M25 (Ø8 Ø7)mm Dimensions (wxhxd): 20x220x90mm Dimensions (wxhxd): 20x220x90mm Weight:,48kg Weight:,4kg 59.V26 59.V27 4

41 ALUBOX Series > JUNCTION BOXES IN ALUMINIUM ALLOY (FOR ZONE 2 AND 22) AL > REFERENCE STANDARDS EN 6240 Electrical apparatus for use in the presence of combustible dust. Part 0: General requirements. EN 624 Electrical apparatus for use in the presence of combustible dust. Part : Protection by enclosures td. EN Electrical apparatus for explosive gas atmospheres. Part 0: General requirements. Suitable for outdoor use. Supplied with enclosure earthing kit. Use only nonsparking components and cable glands compliant with the ATEX directive. EN Electrical apparatus for explosive gas atmospheres. Part 5: Construction, test and marking of type of protection n electrical apparatus. > TECHNICAL CHARACTERISTICS > VERSIONS Enclosure IP66 Mounting plates DIN rail kit ATEX Code: Type of EX protection: II 3GD Ex na II Ex td A22 IP66 T90 C U Operating temperature according to the reference standard: 20 C +60 C Maximum permissible surface temperature: T90 C Protection degree: IP66 Impact resistance: Low mechanical risk (4J) Material: Aluminium alloy IK degree at 20 C: IK08 Cable inlets: Blank sides DIN rail fixing: Yes Colour: RAL 7037 CE Certification type: SCAME ATEX 0U > BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS Saline solution Acids Bases Solvents Concentrated Diluted Concentrated Diluted Hexane Benzol Acetone Alcohol Mineral oil UV rays Resistant Limited Resistance Resistant Limited Resistance Resistant Limited Resistance Limited Resistance Limited Resistance Resistant Resistant Resistant For specific substances please contact our technical service. 42

42 43 ALUBOX Series > DIMENSIONS ENCLOSURES MOUNTING PLATES (Dimension in mm) x5 66x42 92x68 253x27 34x264 40x35 Box reference (mm) I mm L mm M mm N mm A mm External dimensions (with cover) External box dimensions Internal dimensions (with cover) Surface mounting points Useful height B mm C mm D mm E mm c mm d mm e mm F mm 6 6 7, G mm H mm O mm X

43 ISOLATORS Series > SWITCH AND SWITCHDISCONNECTORS > REFERENCE STANDARDS EN Low voltage switchgear and controlgear. Part 3: switches, disconnectors, switchdisconnectors and fusecombination unit. > QUALITY MARKS > VERSIONS Surface mounting Metal Surface mounting Plastic > TECHNICAL CHARACTERISTICS Polarity: P 2P 3P 4P Rated current: 20A32A40A63A Protection degree: IP65IP66 Operating temperature according to the reference standard: 25 C +40 C Max. operating temperature: 60 C Glow Wire test: 650 C Material: Engineering Plastic/Die cast aluminium IK degree at 20 C: Engineering Plastic versions: 20A32A40A: IK07 63A: IK08 Cable inlet: METRIC Colour: Grey RAL 706 (Engineering Plastic) Grey RAL 705 (Metal) ATEX code: 3D II 2GD UNDER DEVELOPMENT 44

44 > BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS Saline solution Resistant Concentrated Limited Resistance > CABLE INLETS Acids Bases Resistant Resistant Resistant Not Resistant Not Resistant Solvents Diluted Concentrated Diluted Hexane Benzol Acetone Alcohol Not Resistant Limited Resistance Mineral oil Resistant UV rays Resistant ISOLATORS Series METAL VERSIONS Enclosure 20A, 32A and 40A (05x50x82) Upper surface: xm20 + xm25 Lower surface: xm20 + xm25 Enclosure 63A Upper surface: 2xM32 Lower surface: 2xM32 PLASTIC VERSIONS Enclosure 20A (5x90x28) Lower surface: xm20 + 2xM25 Enclosure 32A, 40A (5x90x28) Lower surface: xm20 + 2xM32 > APPLICATION EXAMPLES 45

45 ISOLATORS Series > TECHNICAL DATA SWITCHES ( POLE) 20A 32A 40A Rated insulation voltage Ui Rated impulse withstand voltage Uimp Thermal current Ith Thermal current Ithe Vac kv A A Nominal current rating Ie AC22A AC23A Mixed resistite and inductive loads, including moderate overloads Switching off motor loads or other highly inductive loads (3 phase/3 pole) 250V 250V A A Rated shorttime withstand current Icw (s) Conditional shortcircuit current ka Shortcircuit protection: Associate fuse size for conditional shortcircuit current Type gg 500 V ka Rated shortcircuit making capacity Icm ka Permissible wire guage: Flexible wire Rigid wire mm 2 mm

46 > TECHINCAL DATA SWITCHDISCONNECTOR (2, 3, 4 POLES) Rated insulation voltage Ui Rated impulse withstand voltage Uimp Thermal current Ith Thermal current Ithe VAC VDC kv A A 20A A A A ISOLATORS Series AC2A Resistite loads, inluding moderate overloads 400V 500V A A V A Nominal current rating Ie AC22A AC23A AC3 Mixed resistite and inductive loads, including moderate overloads Switching off motor loads or other highly inductive loads (3 phase/3 pole) Squirrelcage motor: starting, switching off motor during running (3 phase/ 3 pole) 400V 500V 690V 400V 500V 690V 400V 690V A A A A A A A A DC2A Resistite loads, including Moderate overloads 300V A DC22A Mixed resistite and inductive loads, including moderate overloads 250V A V A 0(*) 0(*) 0(*) Rated shorttime withstand current Icw (s) A Shortcircuit protection: Conditional shortcircuit current Associate fuse size for conditional shortcircuit current Type gg Rated shortcircuit making capacity Icm kaeff A A General use single phase and 3 phase 600V A UL rating AC motor starting break all line single phase AC motor B, C, D starting break all lines three phase 20V 240V 240V 480V 600V Hp Hp Hp Hp Hp Permissible wire guage: Flexible wire Rigid wire mm 2 AWG mm 2 AWG, ,5 6 68, ,5 6 68, , (*) 2+2 poles in series IMQ approved UL approved 47

47 ISOLATORS Series > DIMENSIONS METAL VERSIONS ENCLOSURE 20A32A40A (05x50x82) ENCLOSURE 63A (50x20x06) 48

48 > DIMENSIONS PLASTIC VERSIONS ENCLOSURE 20A32A40A (5X90X28) ISOLATORS Series 49

49 ADVANCE GRP System > SWITCHED INTERLOCKED SOCKET OUTLETS > REFERENCE STANDARDS EN Plugs, socket outlets and couplers for industrial purposes. Part : general requirements. EN Plugs, socket outlets and couplers for industrial purposes. Part 2: dimensional interchangeability requirements for pin and contacttube accessories of harmonised configurations. EN Plugs, socketoutlets and couplers for industrial purposes. Part 4: Switched socketoutlets and connectors with or without interlock. > VERSIONS WITH MECHANICAL INTERLOCK With switchdisconnector IEC 6240 / EN 6240 Electrical apparatus for use in the presence of combustible dust. Part 0: General requirements. With switchdisconnector and fuse IEC 624 / EN 624 Electrical apparatus for use in the presence of combustible dust. Part : Protection by enclosures 'td'. With fuse and switchdisconnector With molded case circuit breaker with thermal magnetic trip unit 25A 25A > PRODUCTS FOR USE IN A POTENTIALY EXPLOSIVE ENVIRONMENT Scame offers products suitable for installation into environments under potential risk of explosion identified as Zone 22 and that enter into the field of application for the ATEX Directive (European Directive 94/9/CE). With molded case circuit breaker with thermal magnetic and residual current release trip units 25A > VERSIONS WITH ELECTRICAL INTERLOCK With contactor 25A 50

50 > BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS Saline solution Resistant Rated current: Rated voltage: Frequency: Insulating voltage: 6A32A63A25A V~ 50 60Hz 500/690V~ Selfextinguishing GW test: 960 C Selfextinguishing UL94: Switchdisconnectors: 6A32A63A V0 COMMAND Series 25A switch ABB OT 60 Fuse: 6A32A 63A 25A Colour: ATEX Code: Ex Protection type: Operating temperature according to the reference standard: Maximum permissible surface temperature: Switched socket outlets with gg 0,3x38mm gg 22x58mm NH00 Grey RAL7037 II 3D Ex td A22 IP66 T90 C II 2GD UNDER DEVELOPMENT Ta 25 C +60 C 25 C +60 C T90 C interlock degree of Protection: IP66 Plugs degree of Protection: IP66/IP67 Impact Resistance: IK0 (20J) (24V 4J) Switched socket outlets with interlock material: Interlocked switch sockets outlets CE certificate: Acids Concentrated Diluted Concentrated Diluted Hexane Benzol Acetone Alcohol Limited Resistance Resistant Limited Resistance > TECHNICAL CHARACTERISTICS Thermosetting 6A32A3A SCAME ATEX 04 25A: SCAME ATEX 02 Plugs CE certificate: SCAME ATEX 03 Bases For specific substances please contact our technical service. 6A 32A 63A 25A Solvents Thermal magnetic protection: Molded case circuit breaker Thermalmagnetic and residual current protection: Version with contactor: Rated current (A) 6A32A 63A 25A ABB Tmax TB (6kA) with thermal magnetic trip unit TMD (adjustable thermal threshold 0,7 x In fixed magnetic threshold 0 x In) Molded case circuit breaker ABB Tmax TB (6kA) with thermal magnetic trip unit TMD (adjustable thermal threshold 0,7 x In fixed magnetic threshold 0 x In) + residual current release trip units RC22/ (adjustable residual current trip 0,03 0, 3A and time limit for nontrip instantaneous) Contactor CL09 GE POWER CONTROL Upper M32 M40 M63 Mineral oil > WIRING OPERATIONS Wiring capacity of the terminals (mm 2 ) Single socket 2, UV rays Resistant Resistant Resistant Resistant Resistant Resistant Resistant > CABLE ENTRY Maximum entry with cable glands Lower M32 M40 M63 Rated current Socket outlets Plugs (A) Min Max Min Max 2, ADVANCE GRP System 5

51 ADVANCE GRP System > TECHNICAL CHARACTERISTICS 6A32A63A VERSIONS Ample space for easy wiring Outdoor wall fastening Underplate cable runway Switchdisconnector with mechanical lock that can be accessorized with auxiliary contacts Easily extractable support Threaded metal inserts Possibility for plug inserted control microswitch assembly BOTTOM VIEW TOP VIEW Module in hightemperature resistant engineering polymer Possible entry from bottom side (inputoutput also) Selfcentering punch marks to facilitate drilling 52

52 Singlepiece waterproof gasket Highstrength material with superior UV and chemical resistance Ergonomic knob which can be padlocked in position 0 and, manoeuvrable even with gloves ADVANCE GRP System Fuse inspection door, tamperproof, lockable, with assisted opening Dual mechanical lock as required by the ATEX Directive Cover entirely separate from the base for easy installation Captive stainless steel closing screws IDevice An electronic device controls (Intelligence Device) the status of the interlocked socket, monitoring the electrical functionality: operation of the signalling and control card is guaranteed even when the load is not connected; INDICATOR LIGHT ON indicates that the fuses are not open and all the phases are present; indicates that the socket outlet is powered correctly; INDICATOR LIGHT FLASHING signals the interruption of one or more fuses; signals the absence of a phase*; INDICATOR LIGHT OFF indicates that the socket outlet is not powered. * for singlephase products in the event of phase/neutral loss led signaling appears off. 53

53 ADVANCE GRP System > TECHNICAL CHARACTERISTICS 25A VERSION Outdoor wall fastening Ample space for easy wiring Underplate cable runway Threaded metal inserts Switchdisconnector with mechanical lock that can be accessorized with auxiliary contacts Punched marks for easy closure of the cover Easily extractable bottom plate Possibility to assemble microswitch BOTTOM VIEW TOP VIEW Module in hightemperature resistant engineering polymer Possible entry from bottom side (inputoutput also) 54 Selfcentering punch marks to facilitate drilling

ZENITH P Series Increased Safety Enclosures and Terminal Boxes for Applications in Hazardous Environments

ZENITH P Series Increased Safety Enclosures and Terminal Boxes for Applications in Hazardous Environments ZENITH P Series Increased Safety Enclosures and Terminal Boxes for Applications in Hazardous Environments ZENITH P Series Increased Safety Ex e Enclosures / Terminal Boxes > SCAME PARRE S.p.A. Established

More information

ZENITH P Series Increased Safety Enclosures and Terminal Boxes for Applications in Hazardous Environments

ZENITH P Series Increased Safety Enclosures and Terminal Boxes for Applications in Hazardous Environments ZENITH P Series Increased Safety Enclosures and Terminal Boxes for Applications in Hazardous Environments ZENITH P Series Increased Safety Ex e Enclosures / Terminal Boxes > SCAME PARRE S.p.A. Established

More information

SOLUZIONI PER ATMOSFERA ESPLOSIVA

SOLUZIONI PER ATMOSFERA ESPLOSIVA catalogo ATEX 2015 SOLUZIONI PER ATMOSFERA ESPLOSIVA ATEX catalogue book 2016 SOLUTIONS FOR EXPLOSIVE ATMOSPHERES Since 1904 In 1904 PALAZZOLI began its activity in Brescia when electrical energy was first

More information

5. Comparison of IEC Publication and European Standards (EN) Pag Apparatus groups & temperature classes for common flammable materials Pag.

5. Comparison of IEC Publication and European Standards (EN) Pag Apparatus groups & temperature classes for common flammable materials Pag. [Basic concepts for explosion protection] General Index 1. Introduction Pag. 2 2. Group and equipment category Pag. 3 3. North American Standards Pag. 5 4. Conformity Pag. 6 5. Comparison of IEC Publication

More information

Plugs & sockets. Industrial plugs and sockets Scame I-1 5. Industrial switched sockets. Scame I-4 6. Distribution boards.

Plugs & sockets. Industrial plugs and sockets Scame I-1 5. Industrial switched sockets. Scame I-4 6. Distribution boards. 7% Plugs & sockets I Industrial plugs and sockets Scame I-1 5 Industrial switched sockets Scame I-4 6 Distribution boards Scame I-7 8 Industrial plug adaptors Scame I-8 Weatherproof switches and sockets

More information

ATEX catalogue book SOLUTIONS FOR EXPLOSIVE ATMOSPHERES

ATEX catalogue book SOLUTIONS FOR EXPLOSIVE ATMOSPHERES ATEX catalogue book 20172018 SOLUTIONS FOR EXPLOSIVE ATMOSPHERES Since 1904 In 1904 PALAZZOLI began its activity in Brescia when electrical energy was first used in the industry. The Company is specialized

More information

new new Industrial plugs and sockets

new new Industrial plugs and sockets Industrial plugs and sockets 213.1633 213.3236 221.1633 226.1636 New Optima series 16A-32A-63A-125A insulation voltage : 690V AC protection degree : IP44 and IP67 operating temperature : -25ºC to 40ºC

More information

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Ex d EJBX AISI 316L stainless steel - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Quartz sand blasting Warning labels Mounting bracket Silicone gasket

More information

ATEX GENERAL CATALOGUE

ATEX GENERAL CATALOGUE ATEX GENERAL CATALOGUE 016018 ATEX CATALOGUE 016018 www.scame.com The company Scame: a growing group IN LESS THAN FIFTY YEARS WE HAVE BUILT AN INDUSTRIAL BUSINESS THAT HAS ALWAYS PRESERVED THE SPIRIT OF

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity Certificate of Conformity: IECEx SIR 09.0111 http://iecex.iec.ch/iecex/iecexweb.nsf/fc034777969a786bc1256d42005bd791/f076962... Page 1 of 3 22/01/2010 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL

More information

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts. Ex d CCAC - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66 Stainless steel bolts Polyester coating External earth screw Grub screws for opening lid External earth screw

More information

ARGENTA ATEX For potentially explosive atmospheres. ARGENTA ATEX Technical Specifications Wall-mounting cabinets. ARGENTA ATEX Certifications

ARGENTA ATEX For potentially explosive atmospheres. ARGENTA ATEX Technical Specifications Wall-mounting cabinets. ARGENTA ATEX Certifications For potentially explosive atmospheres IDE presents its ATEX certified product range, specially intended for potentially explosive atmospheres, where the degree of protection and strength must be maximised.

More information

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required) FLUORESCENT LIGHTING RMS-560.. Series - Fluorescent lighting fixtures TECHNICAL FEATURES RMS.. series lighting fixtures are ideally suited for ON and OFF-SHORE applications and all kinds of industries

More information

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following

More information

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH Page /3 SPECIFICATION SHEET Ed. Document UTE_ Issued Written Verified Approved MP36350 6-05-05 Strizzi Franco Page /3 INDICE HISTORY... 3 MODIFY RECORDING... 3 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

More information

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0 Officine Meccaniche M.A.M. Apparecchiature Antideflagranti DOCUMENT IS-EJB-A-14 rev. 0 Instructions Flameproof enclosures EJB../W series for command, control, signaling and/or automation Emission date:

More information

Operating Manual MS220KA and MSR220KA

Operating Manual MS220KA and MSR220KA Temperature Relays and MINIKA, Mains Monitoring, Digital Panel meters MINIPAN, Switching Relays and Controls Operating Manual MS220KA and MSR220KA ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße

More information

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236 CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.

More information

Earth-Rite II PLUS Static Earthing System

Earth-Rite II PLUS Static Earthing System READ MANUAL BEFORE COMMENCING WITH INSTALLATION EN Earth-Rite II PLUS Static Earthing System P1 PLUS - DC Supply Installation & Operating Instructions The safety of any system incorporating the equipment

More information

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218 CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.

More information

ATEX - ATmosphere EXplosive

ATEX - ATmosphere EXplosive ATEX - ATmosphere EXplosive 153 DIRECTIVE 94/9/CE (ATEX= ATMOSPHERE EXPLOSIVE) OF THE EUROPEAN PARLIAMENT AND COUNCIL (MARCH 23, 1994): IMPACT ON LIGHTING FIXTURES APPLICATIONS Polycarbonate and steel

More information

Ex LED light fittings

Ex LED light fittings About us TEP Ex is a regional leader in manufacturing of explosion-protected electrical equipment. Through continuous development of new products and markets, modernization of technology and investment

More information

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE Cat. N STOP & GO automatic resetting 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat. N (s) : 4 062 88 / 4 062 89 CONTENTS PAGE 1. Description - Use... 1 2. Product

More information

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

DEB71. Earth Leakage Monitoring Relay. Benefits. Description Earth Leakage Monitoring Relay Benefits Adjustable trip level. Adjustable leakage threshold from 30mA to 5A or from 300mA to 30A. 2 outputs. Two relay outputs provide, besides the alarm signal an additional

More information

Datasheet - AZM 161SK-12/12RK-024

Datasheet - AZM 161SK-12/12RK-024 30.10.2017-13:15:19h Datasheet - AZM 161SK-12/12RK-024 Solenoid interlock / AZM 161 Preferred typ Thermoplastic enclosure Double-insulated Interlock with protection against incorrect locking. 130 mm x

More information

Atmosphere. Introduction. explosion when exposed to a source of ignition. and IEC standards as follows:

Atmosphere. Introduction. explosion when exposed to a source of ignition. and IEC standards as follows: ATEX enclosures Enclosures for explosive atmospheres Introduction PB500061-26 PB500060-47 PB500059-52 Oxygen Heat Chain reaction Fuel Explosive atmosphere Potentially explosive atmospheres: important information

More information

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC EUROPEAN ATEX DIRECTIVE > European Directive 2014/34/EU ATEX Directive 2014/34/EU is a "new approach" directive that applies to protective systems against explosions as well as all equipment used in or

More information

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The entrepreneurial basis of the R. STAHL Technology Group follows a long tradition. The product range is aimed at specialised

More information

1. GENERAL TECHNICAL INFORMATION

1. GENERAL TECHNICAL INFORMATION 1. GENERAL TECHNICAL INFORMATION 1.1 EXPLOSIVE ATMOSPHERES: Every time that dangerous quantities and concentration of flammable gas, vapors mixture or dust clouds exists, risk of explosions may arise.

More information

Manual Power relay SR853

Manual Power relay SR853 Manual Power relay SR853 Product types SR853.8.x.x, Rev. 1 SR853 manual page2 The symbols WARNING, CAUTION, NOTE This symbol warns of a serious hazard. Failure to observe this warning may result in death

More information

Datasheet - AZM 161SK-12/12RK-024

Datasheet - AZM 161SK-12/12RK-024 Print - Create PDF - Create EXCEL file - Hide system components 21.04.2011-14:21:41h Datasheet - AZM 161SK-12/12RK-024 Solenoid interlock / AZM 161 thermoplastic enclosure Double-insulated Interlock with

More information

Technical Ventilation

Technical Ventilation About ventilation of cabinets Nearly all governments place duties on employers to eliminate or control the risks from explosive atmospheres in the workplace. When it comes to storing flammables, the risk

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush

More information

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon INSTRUCTION MANUAL Minialite Intrinsically Safe Round LED This instruction sheet describes installations which conform to EN60079:Part14:2008 Electrical Installation in Hazardous Areas. When designing

More information

Datasheet - AZM ZRK 24 VAC/DC Solenoid interlock / AZM 170

Datasheet - AZM ZRK 24 VAC/DC Solenoid interlock / AZM 170 http://www.schmersal.net/datenblatt?lang=en&produkt=ax4732937owob0f8o2640384... 29/09/2011 Datasheet - AZM 170-11ZRK 24 VAC/DC Solenoid interlock / AZM 170 Preferred typ thermoplastic enclosure Double-insulated

More information

ATM Lighting sp. z o.o

ATM Lighting sp. z o.o INSTALLATION AND MAINTENANCE MANUAL FOR EXPLOSIONPROOF LIGHT FITTING EXL210LED Carefully read the instructions before mounting the light fitting. ATM Lighting sp. z o.o., ul. Budowlanych 31, 80-298 Gdańsk,

More information

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres PRODUCT OVERVIEW Light fittings, boxes & custom built control panels for explosive atmospheres LIGHT FITTINGS, BOXES & CUSTOM BUILT CONTROL PANELS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones

More information

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor Labkotec UK Ltd Adminicle House 1 Lumb Lane Audenshaw Manchester M34 5WH GREAT BRITAIN Tel: 0844 3350 477 Fax: 0161 4281 179 E-mail: info@labkotec.co.uk 10.8.2012 Internet: www.labkotec.co.uk 1/13 OilSET-1000

More information

PROTECT SRB 200EXi-1A

PROTECT SRB 200EXi-1A 2 Installation up to zone 1/21 J S L1 0V X1 X3 S11 S12 S21 S22 Installation up to zone 2 A1 F1 F2 U B U EXi U i 0V S12 S22 X1 X3 K1 Logic K2 K1 K2 13 23 U EXi SRB 200EXi U B -1A U i K1 K2 PA PA A1 A2 13

More information

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG05D-SIL is a flameproof beacon which is certified

More information

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications Force Pressure Temperature Switch Pressure sensors Ex ia I / IIC T6 acc. to ATEX with internal diaphragm with front flush diaphragm Accuracy: 0,25% and 0,5 % Standard output: 4...20 ma; 2-wire system Description

More information

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems LINETRAXX RCMA420 Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems RCMA420_D00059_01_D_XXEN/06.2016 LINETRAXX RCMA420 Residual current monitor for monitoring AC,

More information

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 4.1 Electrical limit switch... 4

More information

EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures

EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures HDL-3-EX* Complete and ready to install Heat Detector with Ex-certified Box, Cable gland and wiring

More information

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4 Areas of application The LSG4 alarm unit is used for monitoring industrial systems, e.g. in the following areas: Alarm and hazard stati in production e.g. for monitoring temperature and pressure in reactors

More information

3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65

3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65 3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65 Product Technical Sheet 18, 36 and 58W single-lamp versions ST.0914.I Summary Application field 3 Structural characteristics 4 Electrical characteristics

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBG15E and BExBG10E Flameproof / Increased Safety Xenon Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG15E and BExBG10E beacons are flameproof

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm

More information

Transportation. Distribution

Transportation. Distribution Distribution Transportation Busbar Shielded Systems type: Cast Resin Low Voltage The shielded busbar system, ISOBUSBAR, type IS isolated in polyester or epoxy resin, have been specifically developed for

More information

Datasheet - MZM 100 ST-SD2PREM-A

Datasheet - MZM 100 ST-SD2PREM-A 19.03.2014-10:31:42h Datasheet - MZM 100 ST-SD2PREM-A Solenoid interlock / MZM 100 Preferred typ Guard locking monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating

More information

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc User manual Explosion-safe window air conditioning system Type series AR-054 II 3 G Ex ic nac h IIC T3 Gc 1. Safety Instructions The window air conditioning series AR-054 is an explosion-safe product suitable

More information

(Notices) EUROPEAN COMMISSION

(Notices) EUROPEAN COMMISSION 14.8.2012 Official Journal of the European Union C 245/1 IV (Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION Commission communication in the framework

More information

TUNNELS BOXES AND CONNECTORS

TUNNELS BOXES AND CONNECTORS TUNNELS BOXES AND CONNECTORS MARECHAL ELECTRIC is now a leading company in the electric connection for tunnels. Based on technology specially intended for such difficult environments and quick light disconnection,

More information

OPTIBAR DP 7060 Supplementary Instructions

OPTIBAR DP 7060 Supplementary Instructions OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,

More information

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ Operating Instructions RTK Instruments Limited PEX7250 Explosion Proof Annunciator Introduction This manual provides the information necessary to install, connect, test and maintain the PEX7250 Explosion

More information

Datasheet - MZM 100 B ST2-SD2PREM-A

Datasheet - MZM 100 B ST2-SD2PREM-A 30.05.2015-14:46:12h Datasheet - MZM 100 B ST2-SD2PREM-A Solenoid interlock / MZM 100 Preferred typ Actuator monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating

More information

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ Operating Instructions RTK Instruments Limited Telephone: 44 (0)1423 580500 Facsimile: 44 (0)1423 580501 DA135 Intrinsically Safe LED Beacon Introduction This manual provides the information necessary

More information

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor DSF xx15.xx xhv Ex-Atex Product ID Type # Product # Drawing # DSF 1215.01 SHV Ex-atex (5m) 304Z-05197 113216 DSF 1415.01 AHV Ex-atex S148 304Z-05256 113351 DSF 1615.01 SHV Ex-atex (5m) 304Z-05196 113214

More information

UV Flame Supervision System

UV Flame Supervision System 7 783 UV Flame Supervision System DETACTOGYR LFE50 Series 02 ISO 9001 The LFE50 is a self-checking UV flame supervision system designed for use with continuously operating burners or for burners running

More information

ATEX Safety Switches. More than safety.

ATEX Safety Switches. More than safety. ATEX Safety Switches More than safety. AUDIN - 8, avenue de la malle - 5370 Saint Brice Courcelles Tel : 03.6.0.0. - Fax : 03.6.0.8.0 - Web : http: www.audin.fr - Email : info@audin.fr ATEX products from

More information

Datasheet - MZM 100 ST2-1P2PWREM-A

Datasheet - MZM 100 ST2-1P2PWREM-A 30.05.2015-14:45:08h Datasheet - MZM 100 ST2-1P2PWREM-A Solenoid interlock / MZM 100 Preferred typ Guard locking monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating

More information

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS Hazardous Areas - EXPLOSIONPROOF SOLENOIDS SOME HISTORY The classification of hazardous areas into zones established the level of protection required for electrical equipment installed in explosive gas

More information

Overload relays. General descriptions. Configuration of the front

Overload relays. General descriptions. Configuration of the front Overload relays General descriptions Type MT, bimetal-style, overload relays are designed to protect AC circuits and motors against overloads, phase failure, long starting times and prolonged stalling

More information

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further. ATEX SOLUTIONS In order to apply a single level for health and safety requirements and to overcome barriers of trade within Europe, national regulations for explosion prevention were harmonized in 1975

More information

DB4 Range - SPEAKERS - Up to 25 Watts

DB4 Range - SPEAKERS - Up to 25 Watts DB Range - SPEAKERS - Up to 5 Watts Hazardous Location, Weatherproof Features UL listed for USA and Canada Class I, Div, Groups A, B, C & D. Class I, Zone, AExd IIC T. CSFM approved. ATEX approved. NEMA

More information

Easy installation Certified for zones 1 and 21 High IP degree of protection

Easy installation Certified for zones 1 and 21 High IP degree of protection Actuating elements Features Easy installation Certified for zones 1 and 21 High IP degree of protection A large number of variants and versions of actuating elements are available for the ComEx control

More information

ISIS SAFETY SYSTEM Installation guide

ISIS SAFETY SYSTEM Installation guide ISIS SAFETY SYSTEM Installation guide CAUTION This information is designed to help suitably qualified personnel install and operate Mechan Safety equipment. Before using this product, read this guide thoroughly

More information

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

OilSET Installation and Operating Instructions. Oil Separator Alarm Device Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 18.11.2010 Internet: www.labkotec.fi 1/10 OilSET-1000 Oil Separator Alarm Device Copyright 2010 Labkotec

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 8 mm non-flush Stainless steel housing Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 8 mm

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 5 mm flush Usable up to SIL2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching element

More information

Rosemount 3490 Series

Rosemount 3490 Series Product Data Sheet July 2014 00813-0100-4841, Rev DA Rosemount 3490 Series 4 20 ma + HART Compatible Controller Field mounted controller with integral multi-function LCD and keypad Tough weatherproof wall

More information

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI500EN 09/2017

More information

This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear

This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear IEC/PAS 62271-109 Edition 1.0 2002-07 High-voltage switchgear and controlgear Part 109: Alternating-current series capacitor by-pass switches PUBLICLY AVAILABLE SPECIFICATION INTERNATIONAL ELECTROTECHNICAL

More information

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Applications Chemical, Petrochemical

More information

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply   - Tel: Systems Index Systems - Systems Systems...1 -.16 General information Description...1 System description...2 Overview...3 Ordering details Arc monitor with detectors...4 Current sensing unit...5 Technical

More information

Description. Applications

Description. Applications CVEP PDS CVEP Convection for Hazardous Heater For Locations Hazardous Locations Convection Heater 1.8 to 9.0kW (T-2A) 280 C (536 F) 1.6 to 4.0kW (T-3A) 180 C (356 F) 1.8 to 9.0kW (T-2) 1.8 300 C to 9.0kW

More information

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements ExTR Reference Number...: ExTR Free Reference Number...: 223531 Compiled by + signature (ExTL)...: Reviewed by + signature (ExTL)...: NO/NEM/ExTR12.0018/00 Stig André Norheim Arne Hortman Date of issue...:

More information

Datasheet - AZM ZRK 24 VAC/DC

Datasheet - AZM ZRK 24 VAC/DC Print - Create PDF - Create EXCEL file - Hide system components 21.04.2011-10:13:56h Datasheet - AZM 170-02ZRK 24 VAC/DC Solenoid interlock / AZM 170 thermoplastic enclosure Double-insulated Compact design

More information

official distributor of Newson Gale Ltd.

official distributor of Newson Gale Ltd. Continuous Ground Loop Monitoring with visual indication. The precision and reliability of the provides enhanced safety and security by continuously testing the connection of the clamp to the container

More information

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights CCA-03EX - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22 Directional LED spotlights Body and lid in coated aluminium LED for proper operation monitoring 127 ED.2018

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-d Edition 09/208 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4

More information

Junction boxes control boxes THU 93.1 THU 93.6 THU 94.1 THU 94.9 PTB 98 ATEX March 1999

Junction boxes control boxes THU 93.1 THU 93.6 THU 94.1 THU 94.9 PTB 98 ATEX March 1999 Junction boxes control boxes THU 93.1 THU 93.6 THU 94.1 THU 94.9 PTB 98 ATEX 3116 March 1999 thuba Ltd. CH-4015 Basle Telefon +41 061 307 80 00 Telefax +41 061 307 80 10 Headoffice@thuba.com www.thuba.com

More information

Equipment and Solutions

Equipment and Solutions Equipment and Solutions Solution [formally technor atex] Subject to errors or changes Editing completed January 2016 Ex-tech Group is located at Forus in Stavanger, Norway, one of the world s top Centers

More information

Beamex. Calibration White Paper. Calibration in hazardous areas

Beamex. Calibration White Paper.   Calibration in hazardous areas Beamex Calibration White Paper info@beamex.com Calibration in hazardous areas This article discusses calibration in hazardous areas and what everyone needs to be aware of before entering into a hazardous

More information

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2 Compliance with EN60079-15: 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2 RJ11FTVX series: rugged and sealed RJ11/12 connectors Report Prepared by : Amphenol Socapex

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators EC-Type Examination Certificate TÜV99 ATEX 1479X Accessories BT32 BT32XS BT32XAS BT33 BT34 V1-G-N4-5M-PUR Female cordset, M12, 4-pin, NAMUR,

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296

More information

AD.3.XG... Atex directive ch. I Page 22 Atex classification ch. I Page 23. Tab.1 Assembly ch. I Page 25

AD.3.XG... Atex directive ch. I Page 22 Atex classification ch. I Page 23. Tab.1 Assembly ch. I Page 25 Atex directive ch. I Page 22 Atex classification ch. I Page 23 Series ch. I Page 24 Technical specifications Ch. I Page 24 Ordering code ch. I Page 24 Tab. Assembly ch. I Page 25 Tab. 2 Voltages ch. I

More information

Gas cylinder scale Model GCS-1

Gas cylinder scale Model GCS-1 Electronic pressure measurement Gas cylinder scale Model GCS-1 WIKA data sheet PE 87.19 Applications Level measurement of liquid gases in gas cabinets and gas distribution systems Level measurement in

More information

TUNNELS BOXES AND CONNECTORS

TUNNELS BOXES AND CONNECTORS TUNNELS BOXES AND CONNECTORS MARECHAL ELECTRIC is now a leading company in the electric connection for tunnels. Based on technology specially intended for such difficult environments and quick light disconnection,

More information

Datasheet - TVS /B-M20

Datasheet - TVS /B-M20 Print - Create PDF - Create EXCEL file 21.04.2011-16:21:01h Datasheet - TVS 400-12/B-M20 Safety switch for hinged guards / Hinge safety switch / TVS 400 / TESZ thermoplastic enclosure Double-insulated

More information

standards: standards:

standards: standards: INSTRUCTION MANUAL D2xB1LD2 LED Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING HAZARD

More information

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation EVL-B Shock-resistant tempered glass - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation costs - Suitable for GAS category IIC LED

More information

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments OMC-158-2 Ex interface unit Manual Version 1.2 August 2017 Author: Observator Instruments Revisions: 0.1 (October 2016) First issue 0.2 (December 2016) Prototype 0.3 (January 2017) Test release 1.0 (March

More information

Operating Manual MS220DA

Operating Manual MS220DA ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße 13, D 74523 Schwäbisch Hall + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA Mains Monitoring Digital Panel Meters MINIPAN

More information

Beamex Calibration White Paper. Calibration in hazardous areas

Beamex Calibration White Paper.  Calibration in hazardous areas Beamex Calibration White Paper info@beamex.com Calibration in hazardous areas This article discusses calibration in hazardous areas and what everyone needs to be aware of before entering into a hazardous

More information

Lloyd s Register Type Approval System Test Specification Number 3

Lloyd s Register Type Approval System Test Specification Number 3 Working together for a safer world Lloyd s Register Type Approval System Test Specification Number 3 July 2015 Performance Test Specification for Equipment to be used in Marine Applications: Electric Cables

More information

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white . TECHNICAL DATA LIGHT FITTING REFLECTOR Polycarbonate tube of 4 mm. thickness Laquered steel painted white END CAPS Aluminium 2030 (polyester paint RAL 7047) POWER SOURCE LAMP TYPE 220-240V, 50/60Hz T8

More information

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax: Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 505 Grünberg Tel.: 00 807-0 Fax: 00 807-259 Insulation monitoring device for unearthed AC/DC systems (IT systems for the supply of operating theatre

More information