RE46C190 3V Photo Smoke Detector IC

Size: px
Start display at page:

Download "RE46C190 3V Photo Smoke Detector IC"

Transcription

1 3V Photo Smoke Detector IC With Programmable Setup, Calibration and Operating Modes Dec 2010 Hello, and welcome to the Microchip Technology Webinar overview of the RE46C190 Three Volt Photo Smoke Detector IC. This Webinar will present the features and functions of this new low voltage programmable smoke detector IC. 1

2 Key Features Operating Voltage from 2V to 5.5V Low Quiescent Current (10 Year Life) Programmable Setup and Calibration Programmable System Features Integrated Horn Driver with Tone Select and Hush Interconnect with Alarm Memory Internal Low Battery and Chamber Test Long Term Drift Adjust & 10 Yr. EOL 2 This low voltage smoke detector IC allows battery operation using 2 alkaline batteries or lithium batteries. The IC can operate from 5 Volts down to 2 Volts. The low quiescent current allows the IC to operate for 10 Yrs using lithium batteries. Programmable setup allows a range Infrared LEDs, photodiodes, and batteries to be used. Programmable calibration provides adjustment for the overall system performance including photo chamber performance. Programmable system features such as horn pattern select, low battery hush enable, long term drift enable, end of life enable, and hush option allow the smoke detector system design to meet specific regulatory requirements and to provide a range of model features with a single IC. The integrated horn driver with boost regulator allows the battery operated device to meet regulatory sound requirements down to 2V. The interconnect of up to 40 devices with local alarm memory allows the source of nuisance alarms to be easily identified in larger alarm configurations. System self checks such as low battery and chamber test insure proper operation of the smoke detector over its operating life. Long term drift adjustment allows the smoke detector system to compensate for component aging or chamber contamination. The end of life indicator provides an indication that the system needs to be replaced. 2

3 3 Analo g&interface ProductDivisio n VBS HSHBLX IRC FE GLE IO VSIRNRLE AP 3VDTES SOI IRE IRPDe vicepi VSm RD CT2 nout E46 ok C19 ed 0etec tori.c. The RE46C190 is provided in a 16 pin SOIC package. 3

4 Unique Strengths Programmable Setup and Calibration So What: The customer has greater freedom in component selection and system design. The programmable IR LED current and photodiode amplifier gain factor and integration time allow a range of IR LED s and photodiodes to be used. Programmable calibration allows the total system performance to be optimized. Manual system adjustment is eliminated. 4 The IC provides programmable setup and calibration. The Infrared LED current has 4 possible values from 50mA to 200mA in 50mA steps. The photo amplifier gain factor can be set from 1 to 4 in steps of 1. The photo amplifier integration time has 4 possible settings from 100 microseconds to 400 microseconds in 100 microsecond steps. The four alarm thresholds have 32 possible settings each. The low battery threshold adjustment provides 8 different thresholds to accommodate different types of batteries. Manual calibration in manufacturing is eliminated. 4

5 Unique Strengths Programmable System Features So What: One part can meet multiple model and regional requirements. Programmable system features allow smoke detectors to conform to different regional regulatory requirements. The smoke detector manufacturer can also program different model features with a single part. 5 Programmable features include tone select, low battery hush enable, hush enable, end of life (EOL) enable, long term drift enable. One part can meet multiple model and regional regulatory requirements. 5

6 Unique Strengths Low Voltage Battery Operation So What: The RE46C190 will operate down to 2.0V which allows operation from low voltage batteries. The programmable low battery voltage detection allows the customer to tailor the system performance to a specific type of battery. 6 Different battery chemistries produce different cell voltages and have different discharge characteristics. The low battery threshold is selectable in eight 100 mv steps from 2.1 to 2.8 volts with a tolerance of 50 mv for each step. The low battery alarm can be disabled for 8 hours if this option is selected since the low battery alarm can become very annoying quickly. 6

7 Unique Strengths Integrated Horn Driver with Selectable Horn Pattern and Hush So What: Loudness requirements can be met at 2V. The horn driver includes a boost regulator which allows the horn to meet regulatory sound pressure requirements. The temporal and continuous horn patterns are programmable as is hush operation. 7 Nine volts is typically required to achieve the necessary piezo horn sound pressure level or volume when the alarm sounds. A boost regulator provides power to the horn driver so the horn will produce the necessary volume. There are 2 horn patterns, continuous and temporal which can be selected depending on regulatory requirements. In addition the boost regulator provides additional headroom for the operation of the infrared LED during low battery conditions insuring consistent operation over battery life. 7

8 Unique Strengths Long Term Drift Adjustment So What: Component aging and/or chamber degradation can shift desired smoke detector characteristics. When enabled the long term drift adjustment compensates for these shifts in the smoke detector operation. The programmability of the IC makes this feature possible. 8 During calibration a no smoke baseline measurement is made and stored in EEPROM. When the long term drift adjustment is enabled, 64 baseline measurements are made over an 8 hour period. This information is compared to the baseline information stored in EEPROM at calibration and a correction factor is calculated to adjust the alarm thresholds. 8

9 Unique Strengths EOL (End Of Life) So What: Li battery and component aging may affect may affect smoke detector effectiveness. When this feature is enabled a 10 year counter is enabled while the part is powered on. When the 10 year limit is reached an alarm will sound. 9 The End of Life feature addresses concerns that after 10 years of powered operation, the smoke detector may not be as effective as needed and should be replaced. This feature is considered especially necessary when the smoke detector is powered by a lithium battery which will allow the smoke detector to operate for 10 years without battery replacement. 9

10 Unique Strengths Reduced Component Count So What: The RE46C190 includes much of the external circuitry needed by previous products provided by Microchip and its competitors. The typical application schematics below illustrate the difference. 10 Components for the gain, alarm thresholds, oscillator and infrared LED biasing have been eliminated. A previous generation smoke detector IC is shown next with the additional components required shown in red. The typical application schematic for the RE46C190 with reduced component is shown next. 10

11 Unique Strengths 11 The 17 components highlighted in red have been incorporated into the RE46C190 IC. The potentiometer, R2, provides manual calibration adjustment. R7 will adjust the infrared LED current. Capacitors C4 and C5 provide the necessary gain setting for the photodiode current. RADJ1 and RADJ2 are used to set the low battery threshold. R9, R12 and C8 set the oscillator frequency. The boost regulator and horn driver provide the required drive to the piezo horn. 11

12 Unique Strengths 12 This schematic shows the components necessary to implement a full featured three volt smoke detector using the RE46C

13 Features, Benefits, Results Feature Benefits Results Low Voltage Operation Low Quiescent Current Programmable Setup Programmable Calibration Programmable Features Integrated Horn Driver with selectable horn patterns and hush Allows low voltage battery operation with extended battery life Allows a wider selection of IR LED s, photodiodes, and batteries for use with a single smoke detector IC Allows different model and regulatory requirements to be met with a single IC A single smoke detector IC provides a complete system solution Eliminates the need for 9V batteries and allows for 10year operation with a LI battery Flexible design options and reduced parts inventory required. Manual calibration eliminated. Reduced parts inventory and manufacturing requirements Reduced parts inventory and manufacturing requirements 13 Low voltage operation and low quiescent current allows low voltage battery operation with extended battery life This eliminates the need for 9V batteries and allows for 10year operation with a lithium battery. Programmable Setup and Programmable Calibration allows a wider selection of infrared LED s, photodiodes, and batteries for use with a single smoke detector IC. This results in flexible design options with a single IC and reduced parts inventory required. Manual calibration is also eliminated. Programmable features allow different model and regulatory requirements to be met with a single IC. This reduces parts inventory and manufacturing requirements. The integrated horn driver with selectable horn patterns and hush allows a single smoke detector IC to provide a complete system solution with reduced parts inventory and manufacturing requirements 13

14 Features, Benefits, Results Feature Benefits Results Interconnect with Alarm Memory Interconnect Digital Filter Interconnect Charge Dump Low Battery Test with Hush Chamber Test Remembers if tripped making it easy to determine which device set off the group. Signal on Interconnect line will not cause false alarms and interconnect line quickly cleared when coming out of alarm state. Test battery for proper operating voltage and hush when necessary Insure proper operation of the photo chamber Defective unit or bad location (for example, by or in a Kitchen or bathroom) can be found. Smoke Alarm will not incorrectly sound on CO event and comes out of alarm state more quickly. Insures proper operation of the smoke detector Insures proper operation of the smoke detector 14 Interconnect with Alarm Memory allows the IC to remember if it was tripped making it easy to determine which device set off the group of smoke detectors. This allows a defective unit or bad location (for example, by or in a Kitchen or bathroom) to be found easily. The Interconnect Digital Filter prevents a carbon monoxide signal on the interconnect line from causing a false alarm. The Interconnect Charge Dump allows the interconnect line to be quickly cleared when coming out of alarm state. The Low Battery Test with Hush allows the battery to be tested for proper operating voltage and allows the low battery alarm to be silenced when necessary. This feature warns the user that the smoke detector is not properly powered. The Chamber Test warns that the smoke detector is not operating properly and allows the end user to replace a defective unit. 14

15 Features, Benefits, Results Feature Benefits Results Long Term Drift Adjustment EOL (End of Life Alarm) Reduced Component Count Corrects for component aging or drift Warns that the smoke detector is 10 years old Reduced inventory and manufacturing costs Insure proper operation of the smoke detector Warns the smoke detector should be replaced Improved margins 15 The Long Term Drift Adjustment corrects for component aging or drift. This insures the proper operation of the smoke detector. The End of Life Alarm warns that the smoke detector is 10 years old and that the smoke detector should be replaced. The Reduced Component Count leads to reduced inventory and manufacturing costs and improved margins. 15

16 Part Numbering Base Part Number: 190 3V, E-Cal, E Highly Integrated, Alarm Memory Photo Smoke Detection RE: Detector Products RE46C190S16TF T&R Pb free Part Type: 46C: Standard (not a custom) Package: S16: SOIC The RE46C190 is a standard product provided in a lead free 16 pin SOIC package which can be taped and reeled. 16

17 Availability Data Sheet available at Pricing in Price Book: US$0.94, each in 10k-unit quantities. Sampling available today at: Volume production available today at: 17 Please visit for the data sheet and additional details. Samples are available at sample.microchip.com and the product can be purchased online at Microchip has made a concerted effort to support the needs of the Smoke Detector industry. From low power operational amplifiers and power management products to the PICmicro and dedicated Smoke Detector I.C.s like the ones we are introducing here look to Microchip for Smoke Detector support. 17

18 Thank You Thank you for your time. 18

Microchip Technology overview of the RE46C180 Programmable Ionization Smoke Detector IC.

Microchip Technology overview of the RE46C180 Programmable Ionization Smoke Detector IC. Microchip Technology overview of the RE46C180 Programmable Ionization Smoke Detector IC. 1 This programmable smoke detector IC allows battery operation using a 9V battery. The low quiescent current extends

More information

RE46C190. CMOS Low Voltage Photoelectric Smoke Detector ASIC with Interconnect and Timer Mode PIN CONFIGURATION. Description.

RE46C190. CMOS Low Voltage Photoelectric Smoke Detector ASIC with Interconnect and Timer Mode PIN CONFIGURATION. Description. CMOS Low Voltage Photoelectric Smoke Detector ASIC with Interconnect and Timer Mode Features Two AA Battery Operation Internal Power On Reset Low Quiescent Current Consumption Available in 16L N SOIC Local

More information

RE46C191. CMOS Low-Voltage Photoelectric Smoke Detector ASIC with Interconnect and Timer Mode. Features: General Description: PIN CONFIGURATION

RE46C191. CMOS Low-Voltage Photoelectric Smoke Detector ASIC with Interconnect and Timer Mode. Features: General Description: PIN CONFIGURATION CMOS Low-Voltage Photoelectric Smoke Detector ASIC with Interconnect and Timer Mode Features: Two AA Battery Operation Low Quiescent Current Consumption Local Alarm Memory Interconnect up to 40 Detectors

More information

Replaced by A5367CA. DISCONTINUED PRODUCT SMOKE DETECTOR WITH INTERCONNECT AND TIMER FEATURES

Replaced by A5367CA. DISCONTINUED PRODUCT SMOKE DETECTOR WITH INTERCONNECT AND TIMER FEATURES Data Sheet 260.8 TIMER START I / O LOW-V SET TIMER OUT + SUPPLY TIMING RES. FEEDBACK 2 3 4 5 6 7 V DD LOGIC OSC. & TIMING DRIVER 8 V SS 9 ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS ) Supply

More information

RE46C200. 9V Programmable Photoelectric Smoke Detector ASIC. Features. Description. Pin Configuration

RE46C200. 9V Programmable Photoelectric Smoke Detector ASIC. Features. Description. Pin Configuration 9V Programmable Photoelectric Smoke Detector ASIC Features 6.5-12V Operation Low Quiescent Current Programmable Internal Infrared Emitter Diode (IRED) Current Programmable Standby Alarm Level Programmable

More information

DISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS

DISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS WITH INTERCONNECT Data Sheet 60.6 NO CONNECT. I / O LOW-V SET NO CONNECT. LED + SUPPLY TIMING RES. FEEDBACK 3 4 5 6 7 NC NC LOGIC OSC. & TIMING DRIVER 0 6 5 4 3 8 V SS GUARD DETECT. IN GUARD SENSITIVITY

More information

Low Voltage Photoelectric Smoke Detector ASIC with Interconnect and Timer Mode

Low Voltage Photoelectric Smoke Detector ASIC with Interconnect and Timer Mode Low Voltage Photoelectric Smoke Detector ASIC with Interconnect and Timer Mode 1.0. INTRODUCTION 1.1 Features Low Quiescent Current Consumption Two AA Battery Operation Internal Power On Reset Local Alarm

More information

SMOKE/CARBON MONOXIDE DETECTOR REQUIREMENTS

SMOKE/CARBON MONOXIDE DETECTOR REQUIREMENTS HOMES BUILT PRIOR TO JANUARY 1, 1975 WITH NO RENOVATIONS As of December 1, 2016, upon sale or transfer Must be located on every level of the residence Must be located on the ceiling at the base of each

More information

Homework 5: Theory of Operation and Hardware Design Narrative

Homework 5: Theory of Operation and Hardware Design Narrative ECE 477 Digital Systems Senior Design Project Rev 8/09 Homework 5: Theory of Operation and Hardware Design Narrative Team Code Name: DijiJock Home Security Group No. 7 Team Member Completing This Homework:

More information

R&E International A Subsidiary of Microchip Technology Inc. RE46C121 CMOS Ionization Smoke Detector ASIC with Interconnect Product Specification

R&E International A Subsidiary of Microchip Technology Inc. RE46C121 CMOS Ionization Smoke Detector ASIC with Interconnect Product Specification RE46C121 General Description The RE46C121 is low power CMOS ionization type smoke detector IC. With few external components this circuit will provide all the required features for an ionization type smoke

More information

R&E International A Subsidiary of Microchip Technology Inc.

R&E International A Subsidiary of Microchip Technology Inc. RE46C141 General Description The RE46C141 is low power CMOS photoelectric type smoke detector IC. With minimal external components this circuit will provide all the required features for a photoelectric

More information

Reflective Optical Beam Smoke Detector User Guide

Reflective Optical Beam Smoke Detector User Guide Reflective Optical Beam Smoke Detector User Guide 1. Installation IMPORTANT NOTE: The infrared beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the system initiating

More information

R&E International A Subsidiary of Microchip Technology Inc.

R&E International A Subsidiary of Microchip Technology Inc. RE46C140 General Description The RE46C140 is low power CMOS photoelectric type smoke detector IC. With minimal external components this circuit will provide all the required features for a photoelectric

More information

R&E International A Subsidiary of Microchip Technology Inc.

R&E International A Subsidiary of Microchip Technology Inc. RE46C146 Intelligent Interconnect and Timer Mode General Description The RE46C146 is low power CMOS photoelectric type smoke detector IC. With minimal external components this circuit will provide all

More information

Melrose Fire Department

Melrose Fire Department Melrose Fire Department Office of Fire Prevention Re: 9/20/18 Guidelines for the Type and Placement of Smoke and Carbon Monoxide Alarms Purpose of this guide is to help homeowners protect their homes and

More information

RE46C165/6/7/8. CMOS Photoelectric Smoke Detector ASIC with Interconnect, Timer Mode and Alarm Memory. Features. Description

RE46C165/6/7/8. CMOS Photoelectric Smoke Detector ASIC with Interconnect, Timer Mode and Alarm Memory. Features. Description CMOS Photoelectric Smoke Detector ASIC with Interconnect, Timer Mode and Alarm Memory Features Temporal Horn Pattern or Continuous Tone Alarm Memory Sensitivity Control Times: - 9 minutes (RE46C165/6)

More information

A5364. Ionization Smoke Detector with Interconnect

A5364. Ionization Smoke Detector with Interconnect Features and Benefits Low average standby current for long battery life Interconnect up to 125 detectors Piezoelectric horn driver Guard outputs for detector input Pulse testing for low battery Power-on

More information

A5348 Ionization Smoke Detector with Interconnect and Timer

A5348 Ionization Smoke Detector with Interconnect and Timer Features and Benefits Low average standby current for long battery life Interconnect up to 125 detectors Piezoelectric horn driver Guard outputs for detector input Pulse testing for low battery Power-on

More information

Batt-Safe Battery String Monitoring System

Batt-Safe Battery String Monitoring System Batt-Safe Battery String Monitoring System Technical White Paper October 2010 Introduction Battery monitoring systems are categorized as either cell monitors or string monitors. Battery cell monitors provide

More information

Smoke Check Service Manual

Smoke Check Service Manual Contents page ON OFF smoke Safety Precaution 2 Important safeguards 2 Looking after your Smoke Check 2 Introduction 2 Before you begin 2 Smoke Check system overview 3 CO sensor 5 Smoke Check exploded view

More information

S TEM PRODUCT SPECIFICATION

S TEM PRODUCT SPECIFICATION NOTE: Some sections of this specification apply only to I87-200-04 or newer. DESCRIPTION: The 2251TEM product is a photo-thermal sensor designed to meet the CEA Guideline for multisensor smoke detectors.

More information

F 2 MC-8FX FAMILY MB95200 SERIES SMOKE DETECTOR DEMO REFERENCE SOLUTION 8-BITMICROCONTROLLER APPLICATION NOTE

F 2 MC-8FX FAMILY MB95200 SERIES SMOKE DETECTOR DEMO REFERENCE SOLUTION 8-BITMICROCONTROLLER APPLICATION NOTE Fujitsu Semiconductor (Shanghai) Co., Ltd. Application Note MCU-AN- 500054-E-10 F 2 MC-8FX FAMILY 8-BITMICROCONTROLLER MB95200 SERIES SMOKE DETECTOR DEMO REFERENCE SOLUTION APPLICATION NOTE Revision History

More information

ARGUS Smoke Detectors. The next generation. Safety and security electronics

ARGUS Smoke Detectors. The next generation. Safety and security electronics ARGUS Smoke Detectors The next generation Safety and security electronics 2 Argus Smoke Detectors The next generation 10.2015 Safety and security electronics Powerful new functions The new ARGUS Smoke

More information

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator TECHNICAL GUIDE Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator The XPlorer Range XPlorer is a new range of analogue addressable detectors and interfaces developed for all who

More information

R&E International A Subsidiary of Microchip Technology Inc.

R&E International A Subsidiary of Microchip Technology Inc. RE46C105 Piezoelectric Horn Driver with oltage Regulator and LED Driver General Description The RE46C105 is a piezoelectric horn driver with a voltage regulator and an open drain NMOS driver suitable for

More information

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head 4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head NET DRAFT version 2.1-2008 Pag. 1 4-20mA Cyber - DRAFT version 2.1-2008 Pag.

More information

Smoke & Carbon Monoxide Alarms

Smoke & Carbon Monoxide Alarms Smoke & Carbon Monoxide Alarms Combination Smoke and Carbon Monoxide Alarms Smoke Alarms Carbon Monoxide Alarms Partners in Safety with Kidde... Worry-Free 10 Year Sealed-In Battery page 2 Kidde Product

More information

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD PART 1 - GENERAL PURPOSE This Standard is intended to assure that fire detection/alarm systems at The University of Texas at Austin provide the highest level of fire safety possible. SCOPE This standard

More information

2014 Alberta Building Code. Part 9 changes relating to Smoke and CO Alarms

2014 Alberta Building Code. Part 9 changes relating to Smoke and CO Alarms 2014 Alberta Building Code Part 9 changes relating to Smoke and CO Alarms 9.32.3.9 Carbon Monoxide Alarms What has not changed: 4) & 6) In a residential occupancy containing a fuel burning appliance or

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL ETLus Listed Patents Pending. All Rights Reserved. Photoelectronic Smoke Detector with Built-in Wireless Transmitter INSTALLATION AND OPERATION MANUAL 1 Model # SD4-SS What smoke detectors can do: Smoke

More information

Smoke Detector Demo Reference Solution

Smoke Detector Demo Reference Solution Fujitsu Microelectronics (Shanghai) Co., Ltd. Application Note MCU-AN- 500054-E-10 F 2 MC-8FX FAMILY 8-BITMICROCONTROLLER MB95200 SERIES Smoke Detector Demo Reference Solution APPLICATION NOTE Smoke Detector

More information

Preliminary Design Report with Diagrams

Preliminary Design Report with Diagrams Medication Alarm Intuitive Dispenser - M.A.I.D Elderly Assistive System Preliminary Design Report with Diagrams EEL4924C - Electrical Engineering Design 2 27 January 2011 Members: Steven Sengberg & Christopher

More information

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY Introduction.

More information

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA 99336 www.jmcvr.com 1-509-586-9893 Table of Contents TABLE OF FIGURES...1 OVERVIEW OF THE HRC CAPABILITIES...2 INSTALLATION AND

More information

PLEASE READ THIS USER GUIDE CAREFULLY

PLEASE READ THIS USER GUIDE CAREFULLY PLEASE READ THIS USER GUIDE CAREFULLY Cavius DIY Smoke Detector Model 2006-001 Manufactured by CAVIUS PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE. For large text

More information

PLEASE READ THIS USER GUIDE CAREFULLY

PLEASE READ THIS USER GUIDE CAREFULLY PLEASE READ THIS USER GUIDE CAREFULLY Cavius DIY Smoke Alarm Model 2008-002 / 10012 / 10013 / 10014 Manufactured by CAVIUS PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE

More information

MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION

MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION DOCUMENT CONTROL NUMBER / MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION 1. INTRODUCTION The MR300 range of optical smoke detectors forms part of the M300 series of plug-in

More information

Europe s Leading Manufacturer of Fire + Carbon Monoxide Alarms

Europe s Leading Manufacturer of Fire + Carbon Monoxide Alarms Europe s Leading Manufacturer of Fire + Carbon Monoxide Alarms Need more info? Call us on +353 (0)61 471277 Ei Electronics e-mail: sales@eielectronics.ie web:www.eielectronics.com Ei Electronics, is an

More information

SMOKE & CARBON MONOXIDE ALARMS

SMOKE & CARBON MONOXIDE ALARMS SMOKE & CARBON MONOXIDE ALARMS COMBINATION SMOKE & CARBON MONOXIDE ALARMS SMOKE ALARMS CARBON MONOXIDE ALARMS Partners in Safety with Kidde... WORRY-FREE 10 YEAR SEALED-IN BATTERY FAST Parts Division of

More information

MODEL 5800A CARBON MONOXIDE (CO) MONITOR AND ALARM SAMPLE-DRAWING TYPE

MODEL 5800A CARBON MONOXIDE (CO) MONITOR AND ALARM SAMPLE-DRAWING TYPE MODEL 5800A CARBON MONOXIDE (CO) MONITOR AND ALARM SAMPLE-DRAWING TYPE 11//07 A153-021500-1 INSTRUCTION MANUAL - MODEL 5800A CO ALARM I INTRODUCTION This MST Model 5800A Carbon Monoxide (CO) Alarm is a

More information

XC10 Extinguishing control panels

XC10 Extinguishing control panels XC10 Extinguishing control panels Market package 2.1 Advanced control panels for detection and alarming as well as for the activation of the extinguishing process Microprocessor-controlled fire detection

More information

Introduction. OM-THA2

Introduction. OM-THA2 Introduction. The OM-THA2 is a multi-function product that monitors Temperature, Humidity and Dew Point, provides alarms for out of range conditions, and continuously logs data. It consists of a base unit

More information

PHOTOELECTRONIC SMOKE DETECTOR

PHOTOELECTRONIC SMOKE DETECTOR PHOTOELECTRONIC SMOKE DETECTOR WITH BUILT-IN WIRELESS TRANSMITTER Installation and Operation Manual 3126052 Model # SD4-MC(US) 418 MHZ TRANSMITTER Document # 108137 General Information Before installing

More information

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel INSTALLATION, OPERATION AND MAINTENANCE MANUAL Version: CN-PM-1000.VER1.1-12/2012 EN54 INFORMATION In accordance with EN 54-2 clause 13.7, the maximum

More information

Public Safety DAS Annunciator Panel

Public Safety DAS Annunciator Panel Public Safety DAS Annunciator Panel 120 VAC Models: 1221-A, 1221-B, 1221-C Revision D 91117 48 VDC Models: 1221-A-48, 1221-B-48, 1221-C-48 24 VDC Models: 1221A-24, 1221-B-24, 1221-C-24 CAUTION: (Read This

More information

Photologic V. OPB9000 Reflective Sensor

Photologic V. OPB9000 Reflective Sensor Photologic V OPB9000 Reflective Sensor Real World Challenges Sensors are exposed to a wide-range of ambient light levels Reliable presence detection is needed to optimize efficiency Detecting small changes

More information

Smoke Alarm and Carbon Monoxide Alarm Installation

Smoke Alarm and Carbon Monoxide Alarm Installation Smoke Alarm and Carbon Monoxide Alarm Installation 2014 1 Protocol Before Installing the Alarm Make sure the resident signs the contract located in the packet. Senior citizens are considered to be those

More information

MFES READY Make your home fire safe. Home Smoke Alarms

MFES READY Make your home fire safe. Home Smoke Alarms MFES READY Make your home fire safe Home Smoke Alarms Working smoke alarms keep you and your family safe. It s the law and it could save your life and the lives of your loved ones. Are you READY to Make

More information

Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door

Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door CAUTION Hinge Edge of Door Wiring Instructions Checkmate Series with Single Point Hold-Open Combination Door Closer-Holder and Releasing Device with or without Integral Smoke Detector INSTALLER: LEAVE

More information

Owners Manual Operating Instructions Patent # 7,081,811

Owners Manual Operating Instructions Patent # 7,081,811 A division of Radiotronics, Inc. Model HA-2510 Owners Manual Operating Instructions Patent # 7,081,811 1556 Cypress Dr Jupiter Fl 33469 Ph 561-746-0935 Fax 561-747-0845 Introduction The K9 Heat Alarm Pro

More information

For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked.

For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked. PHOTOELECTRIC SMOKE AND FIRE ALARM USER S GUIDE MODEL PE120 A.C. Wire-in Single and/or Multiple Station (24 units maximum) Photoelectric Smoke Alarm with 9 Volt Battery Back Up Thank you for purchasing

More information

RE46C162/163. CMOS Ionization Smoke Detector ASIC with Interconnect, Timer Mode and Alarm Memory. Features. Description.

RE46C162/163. CMOS Ionization Smoke Detector ASIC with Interconnect, Timer Mode and Alarm Memory. Features. Description. CMOS Ionization Smoke Detector ASIC with Interconnect, Timer Mode and Alarm Memory Features Pin Selectable Horn Patterns Alarm Memory Sensitivity Control Timer: - 8 minute Timer for RE46C162-1 minute Timer

More information

User guide. for smoke detector

User guide. for smoke detector by User guide for smoke detector OPTICAL SMOKE ALARM DEVICE Commercial reference: 2105-002 Developed by CAVIUS The smoke alarm is designed for private homes, camping trailers, mobile homes and caravans.

More information

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL The LeakMonitor alarm panel is a microprocessor controlled fully adjustable alarm system suitable for multizone

More information

DS1286 Watchdog Timekeeper

DS1286 Watchdog Timekeeper www.dalsemi.com FEATURES Keeps track of hundredths of seconds, seconds, minutes, hours, days, date of the month, months, and years; valid leap year compensation up to 2100 Watchdog timer restarts an out-of-control

More information

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800) The CWSI System The CWSI wireless fire alarm product line offers system versatility like none other. Frequency Hopping Spread Spectrum Technology (FHSS), coupled with Bi-directional RF Communication, Repeater

More information

200 SERIES ADVANCED PHOTO/THERMAL/IR DETECTOR PRODUCT SPECIFICATION

200 SERIES ADVANCED PHOTO/THERMAL/IR DETECTOR PRODUCT SPECIFICATION GENERAL DESCRIPTION This product is the photo/thermal/ir variant of 2 Series Advanced, the redesigned 2 Series all SMD adopting the new chamber and a new style of covers. It works with the 2 Series extended

More information

ALK-V PHOTOELECTRIC SMOKE SENSOR

ALK-V PHOTOELECTRIC SMOKE SENSOR ALK-V PHOTOELECTRIC SMOKE SENSOR APPLICATION The HOCHIKI America ALK-V Photoelectric Smoke Sensor is particularly suited to detecting optically dense smoke typical of fires involving materials such as

More information

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

La Marche Manufacturing Company   Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual La Marche Manufacturing Company www.lamarchemfg.com Option 16 Series Digital Combined Accessory Package Installation and Operation Manual This manual is subject to change without notice. You may obtain

More information

RMS-I-DE-01 Smoke Detector

RMS-I-DE-01 Smoke Detector RMS-I-DE-01 Smoke Detector 2012 CONTEG, spol. s r.o. All rights reserved. No part of this publication may be used, reproduced, photocopied, transmitted or stored in any retrieval system of any nature,

More information

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit D-TECT 2 GJD300 Quad PIR Movement Detector Package Contents Package Contains: 1 x D-Tect 2 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare Sliding Curtains 2

More information

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts Figure 1Document: SPEC-112 Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts construction requirements of UL approved Class H (180 C) insulation system. Transformers

More information

Multi-Point Peripherals

Multi-Point Peripherals UL, ULC Approved* Multi-Point Peripherals TrueAlarm CO Sensor Bases for Smoke, Heat, and Photo/Heat Sensors using IDNet Communications Features Fig 1: TrueAlarm CO Sensor Base with Sounder (shown with

More information

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual ANALOX 5001 ANALOX 5001 Carbon Dioxide Monitor User Manual Analox Sensor Technology Ltd 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT T: +44 (0)1642 711400 F: +44 (0)1642 713900

More information

PRODUCT GUIDE & INFORMATION. Professional Fire & Carbon Monoxide Solutions

PRODUCT GUIDE & INFORMATION. Professional Fire & Carbon Monoxide Solutions PRODUCT GUIDE & INFORMATION Professional Fire & Carbon Monoxide Solutions 1 Nearly 50 years experience of designing, manufacturing and supplying home safety products, makes BRK an industry leader. We believe

More information

End To End Optical Beam Smoke Detector. Additional Information

End To End Optical Beam Smoke Detector. Additional Information End To End Optical Beam Smoke Detector Additional Information EN 1. Multiple Zone Wiring When using more than one System Controller on a single zone of a conventional Fire Control Panel (FCP), it is important

More information

AL600ULADA. NAC Power Extender. Installation Guide

AL600ULADA. NAC Power Extender. Installation Guide AL600ULADA NAC Power Extender Installation Guide Rev. 122000 AL600ULADA - NAC Power Extender Overview: The Altronix AL600ULADA is an extremely cost effective 6.5 amp voltage regulated remote power supply/battery

More information

Product Application Guide- IEC Medical Alarms. cul On-line Listing of Models Approved to IEC :

Product Application Guide- IEC Medical Alarms. cul On-line Listing of Models Approved to IEC : Product Application Guide- IEC60601-1-8 Medical Alarms cul On-line Listing of Models Approved to IEC60601-1-8: UL On-line Listing of Models Approved to IEC60601-1-8: Page 2 Page 3 Piezoelectric Electronic

More information

Open-area Smoke Imaging Detection (OSID)

Open-area Smoke Imaging Detection (OSID) Open-area Smoke Imaging Detection (OSID) www.xtralis.com/osid Large, open spaces warehouses, airports, train stations, stadiums and shopping malls pose unique challenges to reliable fire detection due

More information

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K PEGAsys Multi-Loop Intelligent Suppression Control System A UTC Fire & Security Company Effective: March 2007 K-76-028 FEATURES UL Listed CSFM Approved MEA Approved Peer-to-Peer Networking (to 32 nodes)

More information

169MHz Telecare Devices Carbon Monoxide Detector

169MHz Telecare Devices Carbon Monoxide Detector 169MHz Telecare Devices Carbon Monoxide Detector Compatible with Reach at home alarms, Advent xt warden call, Altec Response and Touchsafe Pro Nursecall systems CO alarm activates on Time Weighted Average;

More information

Operating Instructions Compur Monitox plus

Operating Instructions Compur Monitox plus Operating Instructions Compur Monitox plus Subject to changes without notice. Copyright Compur Monitors München Editor: Compur Monitors GmbH & Co. KG Weissenseestr. 101 D-81539 München Content Page Monitox

More information

Frequently Asked Smoke Alarm Questions

Frequently Asked Smoke Alarm Questions Frequently Asked Smoke Alarm Questions Why should my home have smoke alarms? Most fire deaths are caused by smoke not flames. Most fire deaths and injuries occur between midnight and 8 a.m. when people

More information

Intrusion Outdoor Protection Perimeter

Intrusion Outdoor Protection Perimeter Intrusion Outdoor Protection Perimeter Borders Commercial industrial Military base Correctional institution VIP Estates/Residences Communication Airports Warehouses Perimeter Sensors: the ideal solution

More information

Model ID-441-C InGaAs Near Infrared Detector with Preamplifier and Thermoelectric Cooler Operating Instructions

Model ID-441-C InGaAs Near Infrared Detector with Preamplifier and Thermoelectric Cooler Operating Instructions 15 Discovery Way, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.piacton.com Model ID-441-C InGaAs Near Infrared Detector with Preamplifier and Thermoelectric Cooler Operating Instructions

More information

Conventional Smoke Detectors KFAPO

Conventional Smoke Detectors KFAPO Kingfisher Company, inc. Conventional Smoke Detectors KFAPO Features: Wide operating voltage, 9-33 VDC Advanced electronic technology Flashing LED Magnetic test switch Proven detection performance Designed

More information

OVERVIEW ANNUCIATOR POINTS

OVERVIEW ANNUCIATOR POINTS 4908 McKenna Ct., Columbus, Ohio, 43221 USA (614) 876-6345 www.aircraftextras.com sales@aircraftextras.com Model: AG6 Aircraft Annunciator, Volt/Amp/Temp Meter, Oil Gauge & Fuel Gauge in one Push Button

More information

Wireless Sensors. Security unplugged. Interlogix wireless sensors deliver reliable detection and flexible installation for multiple applications.

Wireless Sensors. Security unplugged. Interlogix wireless sensors deliver reliable detection and flexible installation for multiple applications. Wireless Sensors Security unplugged Interlogix wireless sensors deliver reliable detection and flexible installation for multiple applications. Wireless sensing technology to secure what matters most Designed

More information

PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.

PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE. OPTICAL SMOKE ALARM DEVICE Commercial reference: 2103-002 Developed by CAVIUS The smoke alarm is designed for private homes, camping trailers, mobile homes and caravans. It is not recommended for boats.

More information

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION... 2 2. STANDARD AND OPTIONAL PARTS LIST... 2 3. FEATURE DEFINITIONS... 3 4. TERMINAL DRAWING AND SPECIAL

More information

COMBUSTIBLE GAS LEAK DETECTOR PEN

COMBUSTIBLE GAS LEAK DETECTOR PEN COMBUSTIBLE GAS LEAK DETECTOR PEN USER S MANUAL PNG1 Please read this manual carefully and thoroughly before using this product. Test Equipment Depot - 800.517.8431 99 Washington Street Melrose, MA 02176

More information

Model 3300 Technical Support and Installation Manual

Model 3300 Technical Support and Installation Manual Model 3300 Technical Support and Installation Manual Manual # T15011 Document Revision: A1 1. OVERVIEW 1 2. BASIC OPERATION 1 2.1 General 1 2.2 Field-of-View 2 2.3 Range 2 2.4 Environment 2 2.5 Configuration

More information

Evolution Analogue Addressable Fire System

Evolution Analogue Addressable Fire System Addressable Fire System optimum fire safety systems solutions High speed FSK protocol, uniquely resistant to noise Up to 254 addresses per loop for flexible system design Built to exceptional marine standards

More information

Model GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com

Model GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com Model GD-3300 Combustible Gas Leak Detector Instruction Manual reedinstruments com Introduction The Combustible Gas Leak Detector has a 16 gooseneck probe to find leaks in hard-to-reach areas. It s adjustable

More information

Multi-Point Peripherals

Multi-Point Peripherals Multi-Point Peripherals UL, ULC, CSFM Listed; FM Approved* TrueAlarm CO Sensor Bases for Smoke, Heat, and Photo/Heat Sensors using IDNet Communications Features TrueAlarm addressable CO sensor bases contain

More information

Smoke Alarms and Carbon Monoxide Alarms

Smoke Alarms and Carbon Monoxide Alarms 70 N 1st Street Campbell, California 95008 Phone (408) 866-2130 Fax (408) 871-5101 Smoke Alarms and Carbon Monoxide Alarms March, 2018 When building permits are issued for additions, alterations or repairs

More information

AIR MONITOR & ALARM SYSTEM Installation and Operating Guidelines Version 7.2 Series Software

AIR MONITOR & ALARM SYSTEM Installation and Operating Guidelines Version 7.2 Series Software AIR MOITOR & ALARM YTEM Installation and Operating Guidelines Version 7.2 eries oftware The Air monitor and Alarm ystem is a precision electronic instrument and while designed and built to withstand normal

More information

Group A Carlos Castro, Courtnie Coleman, Lucas Plager, Patrick Schexnayder

Group A Carlos Castro, Courtnie Coleman, Lucas Plager, Patrick Schexnayder Group A Carlos Castro, Courtnie Coleman, Lucas Plager, Patrick Schexnayder Motivation While technology is evolving at a rapid pace, the fire alarm has not seen any innovation. The smoke and fire alarm

More information

Wiring Instructions (01-09)

Wiring Instructions (01-09) CAUTION Wiring Instructions 0--00-0 (0-0) Power Track Series with Single Point Hold-Open Electromechanical Releasing Device with Multi-Point Hold- Open TO PREVENT ELECTRICAL SHOCK AND EQUIPMENT DAMAGE,

More information

SISTEMAS DE SEGURIDAD MIRA, S.L. COMPANY & PRODUCT GUIDE

SISTEMAS DE SEGURIDAD MIRA, S.L. COMPANY & PRODUCT GUIDE SISTEMAS DE SEGURIDAD MIRA, S.L. COMPANY & PRODUCT GUIDE Sistemas de Seguridad Mira, S.L. focuses on the design, development and manufacture of advanced components for fire detection systems. To secure

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

Product Application Guide- Industrial Alarms

Product Application Guide- Industrial Alarms Product Application Guide- Industrial Alarms Part Numbering System LSC Series Part Number Structure LSC 648A NP R Series LSC = 30mm Alarm with LED Lights Voltage Range & Type 628A = 6 to 28 Vac/dc 110

More information

USER INSTRUCTIONS MULTI-SENSOR FIRE ALARM 230V~ with Rechargeable Lithium Cell Back-up. Model: Ei2110

USER INSTRUCTIONS MULTI-SENSOR FIRE ALARM 230V~ with Rechargeable Lithium Cell Back-up. Model: Ei2110 230V~ MULTI-SENSOR FIRE ALARM with Rechargeable Lithium Cell Back-up Model: Ei2110 Contains vital information on unit operation and installation. Read and retain carefully. If you are just installing this

More information

RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009

RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009 RAM GENE-1 ERK MK-Ι & MK-ΙΙ Contamination & Radiation Meter Operating Manual Document #PRIR90N2.DOC Version 2.2 October 2009 Version / Revision Log: RAM GENE-1 ERK/ Operating Manual Ver./Rev.# Date Revised

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR GENERAL The model 6500R is a conventional long range projected beam smoke detector designed to provide

More information

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION... 2 STANDARD AND OPTIONAL PARTS LIST... 2 PARTS DIAGRAM... 3 TERMINAL DRAWING AND SPECIAL NOTES...

More information

L-BAND SATELLITE LEVEL MONITOR INSTALLATION MANUAL

L-BAND SATELLITE LEVEL MONITOR INSTALLATION MANUAL SLM-771 L-BAND SATELLITE LEVEL MONITOR INSTALLATION MANUAL IB 6461-01 SLM-771 L-BAND SATELLITE LEVEL MONITOR DESCRIPTION The SLM-771 is an L-Band Satellite Level Monitor designed to detect measure and

More information

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions EN54-3:2001+A1:2002+A2:2006 EN54-7:2000+A1:2002+A2:2006 EN54-25:2008 0359 Electro Detectors Ltd. Electro

More information

RK Carbon Monoxide Transmitter Operator s Manual

RK Carbon Monoxide Transmitter Operator s Manual 65-2434RK Carbon Monoxide Transmitter Operator s Manual Part Number: 71-0061RK Edition: First, Revision C Released: December 2001 65-2434RK CO Transmitter 1 Product Warranty RKI Instruments, Inc., warranties

More information

B16351-R0-Ei2100 SERIES-USE.qxd 18/9/08 3:47 PM Page 1 230V~ MULTI-SENSOR FIRE ALARM with Rechargeable Lithium Cell Back-up.

B16351-R0-Ei2100 SERIES-USE.qxd 18/9/08 3:47 PM Page 1 230V~ MULTI-SENSOR FIRE ALARM with Rechargeable Lithium Cell Back-up. B16351-R0-Ei2100 SERIES-USE.qxd 18/9/08 3:47 PM Page 1 230V~ MULTI-SENSOR FIRE ALARM with Rechargeable Lithium Cell Back-up Model: Ei2110 Contains vital information on unit operation and installation.

More information