REPORT NUMBER: MID-003r1 ORIGINAL ISSUE DATE: March 11, 2015 Revised Date: March 20, 2015
|
|
- Hugo Stokes
- 6 years ago
- Views:
Transcription
1 REPORT NUMBER: MID-003r1 ORIGINAL ISSUE DATE: March 11, 2015 Revised Date: March 20, 2015 EVALUATION CENTER Intertek Testing Services NA Inc Murphy Drive Middleton, WI TEST REPORT RENDERED TO Rillito River Solar LLC 289 Harrel St Morrisville, VT CONTACT NAME: Mr. Brian Stearns PRODUCT EVALUATED: EcoFasten railless mounting system, Rock-It System EVALUATION PROPERTY: Class A System Fire Class Rating of Panel with Mounting Systems in Combination with Roof Coverings, For Steep Slope Applications. Report of Testing the photovoltaic module roof mount systems by EcoFasten Solar for evaluation with the applicable requirements of: UL 1703 (2014) Section 31.2 and UL 2703 (2015) Sections 15.2 and This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. 1
2 Project No MID-003r1 Page 2 of 10 1 Table of Contents 1 Table of Contents Introduction Test Samples Testing and Evaluation Methods Tests Results Results and Observations Conclusion... 9
3 Project No MID-003r1 Page 3 of 10 2 Introduction Intertek Testing Services NA (Intertek) Fire Testing Laboratory in Middleton, Wisconsin conducted an investigation of the external fire resistance characteristics of a photovoltaic module roof mount system supplied by EcoFasten Solar for a class A application. Samples were submitted to Intertek, Middleton and received in March, 2015 in good condition. The tests were conducted in accordance with the fire resistance criteria of UL 1703 (2014) Section 31.2 and UL 2703 (2015) Sections 15.2 and 15.3 referencing UL 790 (2004) Standard Test Methods for Fire Tests of Roof Coverings. Testing was conducted with Type 1 PV panels, for a steep slope application. The testing was conducted per the requirements of Table 31.2 in UL 1703 (2014). 3 Test Samples The test decks were constructed by Intertek personnel. 1. The test samples were submitted by the client. 2. The test materials were applied by Intertek personnel at Middleton location. The samples are described in more detail in the table below. Deck# Deck Type System 1 Burning Brand Class A Top of PV panel. 3 Interstitial space. Sheathing: 3/8 AC plywood. 2 Burning Brand Class B Brand placed in Interstitial space. 3 Interstitial space. 3 Burning Brand Class A Top of PV panel. 3 Interstitial space. 4 Burning Brand Class B Brand placed in Interstitial Space. 3 Interstitial space. Sheathing: 3/8 AC plywood. Sheathing: 3/8 AC plywood. Sheathing: 3/8 AC plywood.
4 Project No MID-003r1 Page 4 of 10 5 Spread of Flames Class A Steep Slope 3 Interstitial space. Sheathing: 15/32 AC plywood. 6 Spread of Flames Class A Steep Slope 3 Interstitial space. Sheathing: 15/32 AC plywood. 4 Testing and Evaluation Methods The tests were conducted in accordance with the fire resistance criteria of UL 1703 (2014) Section 31.2 referencing UL 790 (2004) Standard Test Methods for Fire Tests of Roof Coverings. The following test equipment was used to conduct the test. Roofing Lab Equipment Inventory Number Measurement Uncertainty Calibration Date ASTM E108 Test Apparatus (Shop) 204 NA Daily Davis Anemometer (A/2-4 BB) 221 ±2% of max reading 1/21/15 Accusplit r 611 ±0.001% (over 3hr. period) 9/8/14
5 Project No MID-003r1 Page 5 of 10 5 Tests Results 5.1. Results and Observations Calibration Test Conditions (Class A ) Air Velocity 1050 average fpm Slope of Cal. Deck 5:12 Average flame temp 1400ºF Ambient air temp. 82ºF Burning Brand Tests Test Observations Deck: 1 Ambient Air Temperature 75ºF Brand Type Class A, 4.54 lbs Brand# Observations deck 1 00:00 PV module. 00:47 Panel bowing upward. 01:29 Back sheet blistering. 01:53 Back sheet smoking. 02:10 Back sheet ignites. 02:44 Ignition of shingles. 04:47 Glass is sagging down. 06:20 Glass shatters, brand falls to deck. 07:52 Smoke and discoloration at horizontal joint, underside. 14:28 Flame out, top side. 32:35 Glow out, brand fully consumed. 90:00 Test stop. Acceptance Level: Class A No flaming of the underside of the deck.
6 Project No MID-003r1 Page 6 of 10 Test Observations Deck: 2 Ambient Air Temperature 79ºF Brand Type Class B, 1.14 lbs Brand# Observations deck 1 00:00 PV module. 01:47 Ignition of shingles. 02:11 Back sheet ignites. 07:14 Brand ¼ consumed. 10:03 Smoke and discoloration of horizontal joint, underside. 10:39 Brand ½ consumed. 19:56 Brand ¾ consumed. 27:46 Flame out, top side. 34:09 Brand fully consumed. 75:00 Test stop. Acceptance Level: Pass No flaming of the underside of the deck. Test Observations Deck: 3 Ambient Air Temperature 84ºF Brand Type Class A, 4.52 lbs Brand# Observations deck 1 00:00 Brand placed between PV module and roof surface. 00:39 Panel bowing upward. 01:16 Back sheet blistering. 01:40 Smoke from back sheet. 02:04 Back sheet ignites. 02:25 Ignition of shingles. 03:15 Glass shatters, brand falls to deck. 10:26 Smoke and discoloration at horizontal joint, underside. 16:15 Discoloration and smoke in plywood, underside. 19:42 Flame out, top side. 38:56 Glow out, top side. Brand fully consumed. 46:54 Glow in plywood, underside. 90:00 Test stop. Acceptance Level: Class A No flaming of the underside of the deck.
7 Project No MID-003r1 Page 7 of 10 Test Observations Deck: 4 Ambient Air Temperature 83ºF Brand Type Class B, 1.16 lbs Brand# Observations deck 1 00:00 Brand placed between PV module and roof surface. 01:20 Ignition of roof surface. 02:42 Back sheet is charring/blistering. 03:22 Back sheet ignition. 07:46 Brand ¼ consumed. 09:32 Smoke and discoloration of horizontal joint, underside. 09:56 Brand ½ consumed. 12:01 Brand ¾ consumed. 16:16 Flame out, top side. 27:45 Glow out, top side. Brand fully consumed. 60:00 Test stop. Acceptance Level: Pass No flaming of the underside of the deck. Spread of Flames Tests Test Observations Deck 5 Ambient Temperature 87 F Panel/Rack Set-Back 3 1 Distance (feet-inches) Observations/Comments 00:00 Burner ignited. 01:52 Ignition of asphalt shingles. 03: : : :00 Test stop. Results: Class A. Maximum spread of flames is 3 0.
8 Project No MID-003r1 Page 8 of 10 Test Observations Deck 6 Ambient Temperature 88 F Panel/Rack Set-Back 3 1 Distance (feet-inches) Observations/Comments 00:00 Burner ignited. 01:46 Ignition of asphalt shingles. 03: : :00 Test stop. Results: Class A. Maximum spread of flames is 2 11.
9 Project No MID-003r1 Page 9 of 10 6 Conclusion The results of the Class A System Fire Class Rating of Photovoltaic Panels with Mounting Systems in Combination with Roof Coverings, For Steep Slope Applications is stated in the following table. The Rock-It System mount, was provided by EcoFasten Solar and testing included the use of Type 1 photovoltaic panels. Testing was conducted per UL 1703 (2014) Section 31.2 and UL 2703 (2015) Sections 15.2 and 15.3 referencing UL 790 (2004) Standard Test Methods for Fire Tests of Roof Coverings. Sample Surface Material Test Results 1 EcoFasten PV mounting system with Type 1 panel Burning Brand Class A 2 EcoFasten PV mounting system with Type 1 panel Burning Brand Pass 3 EcoFasten PV mounting system with Type 1 panel Burning Brand Class A 4 EcoFasten PV mounting system with Type 1 panel Burning Brand Pass 5 EcoFasten PV mounting system with Type 1 panel Spread of Flames Pass 6 EcoFasten PV mounting system with Type 1 panel Spread of Flames Pass The EcoFasten Solar mounting system Rock-It System and Type 1 photovoltaic panel for steep slope application met the requirement for a Class A fire application in accordance with UL 1703 (2014) Section 31.2 and UL 2703 (2015) in compliance with UL 790 (2004) Standard Test Methods for Fire Tests of Roof Covering at for steep slope applications. The Rock-It System system with South facing array skirt maintained a 3 interstitial space. This report does not automatically imply product certification. Products must be under a certification program and bear the Warnock Hersey registered certification mark to demonstrate compliance. INTERTEK TESTING SERVICES NA Reported by: Chad Naggs Technician II, Fire Resistance Intertek, Building Products Reviewed by: Gregory Allen len Engineering Team Leader, Openings Intertek, Building Products
10 Project No MID-003r1 Page 10 of 10 REVISION SUMMARY DATE March 11, 2015 March 20, 2015 SUMMARY Initial report Revised product name per clients request
ENGINEERING EVALUATION
ENGINEERING EVALUATION REPORT NUMBER: 100378137MID-002 ORIGINAL ISSUE DATE: April 26 th, 2011 REVISION AND DATE: Original EVALUATION CENTER Intertek 8431 Murphy Drive Middleton, WI 53562 RENDERED TO Hanchett
More informationTEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1
REPORT NUMBER: 101145164COQ-005 ORIGINAL ISSUE DATE: April 25, 2013 TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd. 1500 Brigantine Drive Coquitlam, B.C. V3K 7C1 RENDERED TO udecor Inc.
More informationRENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy
REPORT NUMBER: 100900037COQ-002 ORIGINAL ISSUE DATE: October 10, 2012 TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd. 1500 Brigantine Drive Coquitlam, BC V3K 7C1 RENDERED TO Laminam S.P.A.
More informationTEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source
NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source TEST REPORT Kolay 5mm 20mil Wear Layer LVT with Fiberglass Core Project
More informationRENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3
REPORT NUMBER: 101207560COQ-001b ORIGINAL ISSUE DATE: June 12, 2013 TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd. 1500 Brigantine Drive Coquitlam, B.C. V3K 7C1 RENDERED TO Vipco Industries
More informationREPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:
Page 1 of 10 TEST REPORT REPORT NUMBER: 102317918SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE: EVALUATION CENTER Intertek Testing Services NA Inc. 16015 Shady Falls Road Elmendorf, TX 78112
More informationFire Performance of Translucent Systems
Fire Performance of Translucent Systems ASTM E-108 Burning Brand Test on Quadwall Class A Approved Light Transmitting Plastics Fire Test Performance Meets Building Code Requirements: Self-Ignition ASTM
More informationSIGMADEK, LTD. FIRE TEST REPORT
SIGMADEK, LTD. FIRE TEST REPORT SCOPE OF WORK ASTM E84 TESTING ON ALUMINUM EXTRUSION DECK BOARD C/W PORCELAIN TILE INSERT REPORT NUMBER H5331.01-121-24 TEST DATE 09/13/17 ISSUE DATE 10/03/17 RECORD RETENTION
More informationFABRITRAK SYSTEMS, INC. FIRE TEST REPORT
FABRITRAK SYSTEMS, INC. FIRE TEST REPORT SCOPE OF WORK ASTM E84 TESTING ON POLYESTER INFILL REPORT NUMBER H5200.01-121-24 TEST DATE 08/31/17 ISSUE DATE 09/20/17 RECORD RETENTION END DATE 08/31/21 PAGES
More informationRENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5
REPORT NUMBER: 3189147COQ-002 ORIGINAL ISSUE DATE: September 30, 2009 TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd. 1500 Brigantine Drive Coquitlam, B.C. V3K 7C1 RENDERED TO Radial Engineering
More information1.0 INTRODUCTION 2.0 CLASSIFICATION CRITERIA
1.0 INTRODUCTION This report presents the results of an investigation of the external fire resistance characteristics of the VELUX FCM Deck Mounted Skylight roof covering system in general accordance with
More informationPERFORMANCE TEST REPORT. Rendered to: Metal Building Manufacturers Association Cleveland, Ohio
PERFORMANCE TEST REPORT Report No.: F6398.01-121-24 Test Date: March 9 th & 10th, 2016 Rendered to: Metal Building Manufacturers Association Cleveland, Ohio ASSEMBLIES: Metal Roof Panels and Clay Roof
More informationReport on the Fire Testing of a Roofing System with a Synthetic Underlayment in Accordance with ASTM E a. Trinity ERD Columbia, SC
Report on the Fire Testing of a Roofing System with a Synthetic Underlayment in Accordance with ASTM E 108-07a Rendered to: Trinity ERD Columbia, SC WFCi Project # 10135 & 11159 Testing Completed on: April
More informationFUNDERMAX GMBH FIRE TEST REPORT
FUNDERMAX GMBH FIRE TEST REPORT SCOPE OF WORK ASTM E84 TESTING ON 19 MM MAX COMPACT REPORT NUMBER I0002.02-121-24 TEST DATE 01/29/18 ISSUE DATE 02/16/18 RECORD RETENTION END DATE 01/29/22 PAGES 10 DOCUMENT
More informationPRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona
Architectural Testing PRODUCT PERFORMANCE TEST REPORT Report No.: D7226.01-121-24 Test Date: May 29, 2014 Rendered to: Natural Light Energy Systems Phoenix, Arizona PRODUCT TYPE: Tubular Daylight Device
More informationRefrigerating Appliance DOE Test Report
Report Number Test Laboratory Name / Address Applicant Name / Address Manufacturing Name / Address Product Brand Name Description Model(s) (if applicable) Model Similarity Ratings Refrigerating Appliance
More informationIntertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008
Intertek I 0:: o D.. W 0:: I en w I REPORT NUMBER: 3161466SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: EVALUATION CENTER Intertek Testing Services NA Inc. 16015 Shady Falls Rd. Elmendorf,
More informationREPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630
REPORT 58 COMMERCENTRE DRIVE, LAKE FOREST, CA 963 Project No. G119188 Date: March 13, REPORT NO. 119188LAX-4 TEST OF ONE LED WASH MODEL NO. COLOUR CHORUS 4 RENDERED TO ELATION PROFESSIONAL 61 S. EASTERN
More informationREPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630
REPORT 58 COMMERCENTRE DRIVE, LAKE FOREST, CA 963 Project No. G67677 Date: June 6, 4 REPORT NO. 67677LAX- TEST OF ONE FULL ON AT 9 BEAM ANGLE MODEL NO. RAZOR Q ZOOM RENDERED TO ELATION PROFESSIONAL 6 S.
More informationREPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630
REPORT 58 COMMERCENTRE DRIVE, LAKE FOREST, CA 93 Project No. G138456 Date: April, 16 REPORT NO. 138456LA-51 TEST OF ONE CYCLORAMA WALL WASH LUMINAIRE MODEL NO. TVL CYC RGBW RENDERED TO ACCLAIM LIGHTING
More informationREPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045
REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 FOR THE SCOPE OF. ACCREDITATION UNDER NVLAP LAB CODE 100402-0.. Project No. G101537614 Date: April 8, 2014 REPORT NO. G101537614CRT-005 TEST OF ONE LED
More informationTEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria
TEST REPORT Report No.: E6736.01-121-24 Test Date: May 6, 2015 Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria PRODUCT TYPE: Max Exterior F-Quality SERIES/MODEL: Décor. 0085 TEST METHOD:
More informationREPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630
REPORT 58 COMMERCENTRE DRIVE, LAKE FOREST, CA 96 Project No. G85 Date: April 6, 5 REPORT NO. 85LAX- TEST OF ONE WALL BRACKET JELLY JAR MODEL NO. H-CGU--B LED MODEL NO. BRIDGELUX BXRC-E-C-X DRIVER MODEL
More informationTEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota
Architectural Testing TEST REPORT Report No.: D7913.05-121-24 Rendered to: 3M COMPANY St. Paul, Minnesota PRODUCT TYPE: Window Film SERIES/MODEL: 3M Scotchshield Ultra 800 TEST METHOD: ASTM E 84-11a, Standard
More informationREPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005
. REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 Project No. G102748333 Date: December 20, 2016 REPORT NO. 102748333CHI-015 TEST OF ONE T8 LED TUBE MODEL NO. T8-NW18F LED MODEL NO. HONGLI OPTO-ELECTRONIC
More informationREPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630
FOR THE SCOPE OF ACCREDITATION UNDER A2LA TO ISO/IEC 17025:2005. REPORT 25800 COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 Project No. G101786356 Date: August 19, 2014 REPORT NO. 101786356LAX-001 TEST OF
More informationJanuary 26, Mr. Larry Sunshine Bentax USA 418 Meadow Street Fairfield CT Dear Mr. Sunshine:
January 26, 2005 Mr. Larry Sunshine Bentax USA 418 Meadow Street Fairfield CT 06824 Dear Mr. Sunshine: We appreciate the opportunity to be of service to you. Please find enclosed one bound copy of Intertek
More informationREPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005
. REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 Project No. G102748333 Date: January 24, 2017 REPORT NO. 102748333CHI-018 TEST OF ONE LED EPLOSION PROOF LIGHT MODEL NO. EPL-NW200 LED MODEL NO.
More informationREPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045
REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 FOR THE SCOPE OF ACCREDITATION UNDER NVLAP LAB CODE 100402-0. Project No. G101030158 Date: February 26, 2013 REPORT NO. 101030158CRT-001 TEST OF ONE LED
More informationRoof Coatings Manufacturers Association October 18, 2012
Roof Coatings Manufacturers Association October 18, 2012 Examples of Addressing New Fire Challenges & Risks With Science Bob Backstrom Kevin Faltin UL and the UL logo are trademarks of UL LLC 2012 New
More informationPERFORMANCE TEST REPORT. Rendered to: EVERBLOCK SYSTEMS, LLC. PRODUCT: Modular Block Product
PERFORMANCE TEST REPORT Rendered to: EVERBLOCK SYSTEMS, LLC PRODUCT: Modular Block Product Report No.: G1320.01-106-31 Report Date: 08/04/16 Test Record Retention Date: 07/29/20 130 Derry Court York, PA
More informationREPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005
. REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 Project No. G102748333 Date: February 21, 2017 REPORT NO. 102748333CHI-024 TEST OF ONE LED WALL PACK MODEL NO. WPFC-CW70 LED MODEL NO. PHILIPS
More informationREPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005
. REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 Project No. G102671575 Date: July 27, 2016 REPORT NO. 102671575CHI-002 TEST OF ONE ROADWAY/AREA LUMINAIRE MODEL NO. APL-NW200 LED MODEL NO. SAMSUNG
More informationRefrigerating Appliance ErP Test Report
Report Number Test Laboratory Name / Address Applicant Name / Address Manufacturing Name / Address Product Brand Name Description Model(s) (if applicable) Model Similarity Ratings Date of receipt of sample(s)
More informationDeclaration of Conformity
Declaration of Conformity We, Paradox Security Systems Ltd. (manufacturer's name) 780 Industrial Boulevard, St. Eustache, Quebec, Canada, J7R 5V3 (manufacturer's address) declare under our responsibility
More informationBURNING BRAND PERFORMANCE TEST REPORT. Rendered to: VELUX AMERICA, INC. SERIES/MODEL: TGF/TGR (Acrylic Dome) VELUX SUN TUNNEL
BURNING BRAND PERFORMANCE TEST REPORT Rendered to: VELUX AMERICA, INC. SERIES/MODEL: TGF/TGR 022 0000 (Acrylic Dome) VELUX SUN TUNNEL ACCESSORY PRODUCTS: Tubular Skylight with ZTA 022 000090 9" Turrets
More informationFLASHLIGHT ANSI STANDARDS
FLASHLIGHT ANSI STANDARDS While Pelican was one of the first manufacturers to use quantifiable test procedures, the need was recognized to develop a common language that customers could use to select the
More informationEffect of Rack Mounted Photovoltaic Modules on the Fire Classification Rating of Roofing Assemblies
Effect of Rack Mounted Photovoltaic Modules on the Fire Classification Rating of Roofing Assemblies Project Number: 08CA39594, 09CA40917 File Number: IN15911, R26475 Date: September 30, 2009 Revised February
More informationResearch-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly
Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly ASTM E119-98: Standard Test Methods for Fire Tests of Building Construction and Materials* *Research-scale horizontal
More informationREPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727
REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727 Project No. G101464624CRT-001 Date: January 17, 2104 INTERTEK REPORT NO. G101464624CRT-001 DIALIGHT REPORT NO. L13029 TEST OF ONE LSA ATEX ZONE
More informationReport Of Surface Burning Characteristics Tests On Coated Louvered Door Panels As Submitted By Contego International Inc.
August 11, 2017 Contego International Inc. Mr. Danny French PO Box 49 Rochester, IN 46975-0049 Our Reference: R25382 / 4788022828 Subject: Report Of Surface Burning Characteristics Tests On Coated Louvered
More informationFIRE RETARDANT ARCHITECTURAL WOOD COATING FIRE SHIELD FS020 FIRE-SHIELD SEALER. FS021 FIRE-SHIELD TOP COAT Available in different gloss
FIRE RETARDANT ARCHITECTURAL WOOD COATING ASTM E84 CLASS A FIRE SHIELD FS020 FIRE-SHIELD SEALER FS021 FIRE-SHIELD TOP COAT Available in different gloss www.duro-lak.com Easy to apply Water base sealer
More informationReport Of Surface Burning Characteristics Tests On Samples As Submitted By Textures 3D
November 10, 2014 Mr. Carlos Khantzis Textures 3D 31280 Oak Crest Dr. #4 Westlake Village, CA 91361 Our Reference: Subject: SV19490/4786557998 Report Of Surface Burning Characteristics Tests On Samples
More informationAbrasion Resistance of Fluoropolymer and polyester Coatings
Abrasion Resistance of Fluoropolymer and polyester Coatings British Standards British Standard 476 refers to fire tests on building materials and structures. The parts of this standard that are of most
More informationReport Of Surface Burning Characteristics Tests On Samples As Submitted By Railtech Ltd.
May 22, 2013 Mr. Herbert Wheeler Railtech Ltd. 325 Ave. Lee Baie-D urf, QX 3S3 Canada Our Reference: Subject: R26549/13CA21763 Report Of Surface Burning Characteristics Tests On Samples As Submitted By
More informationJuly 22, Stewart Audio Inc. Brian Mccormick Po Box 4058 Mountain View, CA File SV17764 / Project 09CA34798
July 22, 2009 Stewart Audio Inc Brian Mccormick Po Box 4058 Mountain View, CA 94040 Our Reference: Subject: File SV17764 / Project 09CA34798 UL Standard 2043, Third Edition "Fire for Heat and Visible Smoke
More informationMaterials Testing by Gregory Havel
Materials Testing by Gregory Havel July 24, 2017 One of the most common tests cited in the technical bulletins on building materials is ASTM E84 Standard Method of Test of Surface Burning Characteristics
More informationReport of Surface Burning Characteristics Tests on Skyfold Panel Samples As Submitted By Railtech Ltd
November 29, 2010 Revised: January 10, 2013 Revised: January 18, 2013 Mr. Herbert Wheeler Railtech Ltd. 325 Ave Lee, Baie-D Urf QC H9X 3S3 Canada Our Reference: Subject: R26549/09CA56627 Report of Surface
More informationThis document is a preview generated by EVS
TECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CLC/TR 50670 December 2016 ICS 13.220.50; 27.160; 91.060.20 English Version External fire exposure to roofs in combination with photovoltaic (PV)
More informationReport Of Surface Burning Characteristics Tests On Samples As Submitted By Ebrille SRL
May 18, 2015 Mr. Simone Furiato Ebrille SRL S S Canelli 53/A Nizza Monferrato, AT 14049 Our Reference: Subject: SV29774/4786853196 Report Of Surface Burning Characteristics Tests On Samples As Submitted
More informationThe Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318
Retardants Inc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 21 Chaska, MN 55318 952-448-7377 FAX:952-448-2613 Fire Retardant HOT LINE 1-8-913-9385 e-mail: info@fireretardantsinc.com
More informationReport of Surface Burning Characteristics Test on Acoustical Panel
January 02, 2013 Ideacustik Christian Morales Torres Gerente General Av. Quito 3620 y Bolivia Guayaquil, Ecuador Our Reference: Subject: R27636 / 12CA68539 Report of Surface Burning Characteristics Test
More informationReport of Surface Burning Characteristics Tests on Samples As Submitted By Jotun UAE Ltd (LLC)
February, 11 Revised February 28, 11 Jotun UAE Ltd (LLC) Mr. Richard Mann Al Quozind District Dubai, 3671 UAE Our Reference: Subject: SV18666/11CA24 Report of Surface Burning Characteristics Tests on Samples
More informationPERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome
PERFORMANCE TEST REPORT Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome Report No: D3964.01-106-31 Report Date: 06/19/14 Test Record Retention Date: 06/03/18 130 Derry Court York, PA
More informationReport Of Surface Burning Characteristics Tests On Felt Material As Submitted By Rieke Office Interiors
February 2, 16 Rieke Office Interiors Mr. Todd Rieke Fox Ln. Elgin, IL 6123 Our Reference: SV3565 / 4787326412 Subject: Report Of Surface Burning Characteristics Tests On Felt Material As Submitted By
More informationSouthern California Gas Company Customer Programs Department
Appliance Test Report SCGAT140220A Revision 0 Issued Date: March 2014 Duke 613Q-G1V Gas Convection Oven Performance Test Per ASTM F1496-13 Southern California Gas Company Customer Programs Department Food
More informationTECHNICAL MANUAL for FIRE TAPE. E-Z TAPING SYSTEM PO BOX GREEN BAY, WI
TECHNICAL MANUAL for FIRE TAPE E-Z TAPING SYSTEM PO BOX 10887 GREEN BAY, WI 54307 800-721-8273 http://www.e-ztape.com Product Description Fire Tape Manufacturer Alwin Manufacturing Company owns All Products,
More informationTECHNICAL MANUAL for FIRE TAPE. E-Z TAPING SYSTEM PO BOX GREEN BAY, WI
TECHNICAL MANUAL for FIRE TAPE E-Z TAPING SYSTEM PO BOX 10887 GREEN BAY, WI 54307 800-721-8273 http://www.e-ztape.com Table of Contents Product Description... 3 Fire Tape Manufacturer... 3 Fire Tape Listed
More informationWe Identify and S.T.O.P. Your Noise Problems
ASTM E-84 TESTING FOR MANUFACTURER, RENDERED TO: Acoustical Surfaces Inc. 123 Columbia Court North, Suite 201 Chaska, MN 55318 Noise S.T.O.P. Fabrisorb Acoustical Wall Panels TESTED: OCTOBER 3, 2002 October
More informationBCTC CARPET TECHNICAL CENTRE
Wira House West Park Ring Road Leeds, LS16 6QL Tel: +44 (0)113 259 1999 Fax: +44 (0)113 278 0306 Web: http://www.bttg.co.uk/bctc Email: CSLeeds@bttg.co.uk 7 September 2010 Page 1 of 7 Client: Rectory Farm
More informationF, T, L and W Ratings - What are the Code & Testing Requirements?
F, T, L and W Ratings - What are the Code & Testing Requirements? Rich Walke Underwriters Laboratories Inc. April 27, 2010 Copyright 1995-2007 Underwriters Laboratories Inc. All rights reserved. No portion
More informationPERFORMANCE TEST REPORT. Rendered to: PALRAM AMERICAS, INC. PRODUCT: Clear Palsun TYPE: Polycarbonate
PERFORMANCE TEST REPORT Rendered to: PALRAM AMERICAS, INC. PRODUCT: Clear Palsun TYPE: Polycarbonate Report No: C7626.1-16-31 Report Date: 5/8/13 Test Record Retention Date: 5/8/17 PERFORMANCE TEST REPORT
More informationLeading. Click to edit Master subtitle style. 3M Fire Protection Products Awareness & Introduction to 3M Fire Protection Products
Click to edit Master subtitle style Leading Agenda Why Fire Protection is Critical? Building Codes & Fire Test Standards Third-Party Listings WHY FIRE PROTECTION IS CRITICAL? Al Nasser Tower - Qatar USA
More informationRooftop Photovoltaic (PV) Systems Examining the Risks and Researching the Options
2016 NFPA Conference & Expo Rooftop Photovoltaic (PV) Systems Examining the Risks and Researching the Options Presented by: Joel Sipe Senior Managing Engineer Exponent Inc. Outline Project Background Fire
More informationViewing a PV system fire test at Underwriters Laboratories STEVEN BUSHONG ASSOCIATE EDITOR
STEVEN BUSHONG ASSOCIATE EDITOR Viewing a PV system fire test at Underwriters Laboratories If a roof with installed PV modules is exposed to a fire, will the solar array help or hinder the flames? Until
More informationXRRS Specification Fire Ready Hood
XRRS Specification Fire Ready Hood ************************************************************************************************************************ Note to User: This document is subject to copyright
More informationIn Situ Temperature Measurement
Ref. No.: Version: 1.0 IESNA SUSTAINING MEMBER LCGP16030138 Date of issue: Mar. 28, 2016 Total pages: 8 Test report of In Situ Temperature Measurement Rendered to: GLL Shenfubao Industry Park, Bonded Area,Futian
More informationAcoustical Surfaces, Inc.
S.T.O.P. February 21, 2013 Our Reference: Subject: SV19452/13CA09185 Report Of Surface Burning Characteristics Tests On Samples This is a Report summarizing the results of a test conducted under the Commercial
More informationLAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:
LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: ALPHA TRACK Method Number: ELAP method number 7035 SOP Number: Revision Number: SOP Date: Personnel / Data Records observed: Page 1 of 6 RADON IN AIR
More informationTECHNICAL MANUAL for FIRE TAPE. E-Z TAPING SYSTEM PO BOX GREEN BAY, WI
TECHNICAL MANUAL for FIRE TAPE E-Z TAPING SYSTEM PO BOX 10887 GREEN BAY, WI 54307 800-721-8273 http://www.e-ztape.com Table of Contents Product Description...3 Fire Tape Manufacturer...3 Fire Tape Listed
More informationRISKTOPICS. Photovoltaic systems
RISKTOPICS Photovoltaic systems May May 2014 2014 INTRODUCTION Photovoltaic systems installed on or integrated into buildings components introduce a variety of potential challenges and risks. The challenges
More information+ = FIRE LABORATORY INTRODUCTION. APPLUS+ LGAI - Our company history. High Technology Knowledge. Customer Confidence. Branding
INTRODUCTION APPLUS+ LGAI - Our company history As a brief resume of our history LGAI - Laboratori General d'assaigs i Investigacions (whose commercial name was LGAI Technological Center) was fully owned
More informationEngineering Report Vibration Test for Intertek Testing Services Prepared by Approved by 9725 Girard Avenue South Minneapolis, MN 55431
Engineering Report 47566-1 Vibration Test for Intertek Testing Services Prepared by Michael J. Caron, Test Engineer Lee R. Senne, Test Technician Approved by Kent L. Erickson, Dynamics Division Manager
More informationReport of Surface Burning Characteristics Tests on Samples As Submitted By Eco-Sol Ltd
October 05, 2011 Eco-Sol Ltd Mr. Paul Allcock Cardiff House Cardiff Rd Barry, Vale of Glamorgan, CF63 2AW Great Britain Our Reference: Subject: R27181/11CA40094 Report of Surface Burning Characteristics
More informationEngineering Submittal Data PPRTH Patio Radiant Tube Heaters.
12288 Brawn Road 22, Wainfleet, Ontario, Canada L0S 1V0 Phone: 905-899-3473 Fax: 905-899-2262 www.easyradiantworks.com email: erw@vaxxine.com P For either indoor or outdoor installation. Not for use in
More informationCAN/ULC-S102 Surface Burning Characteristics of "8 mm Fire Rated High Pressure Laminate Phenolic Panel"
ELECTRONIC DRAFT COPY CAN/ULC-S12 Surface Burning Characteristics of "8 mm Fire Rated High Pressure Laminate Phenolic Panel" A Report To: ABET Corporation 5 Paxman Road, Unit 1 Toronto, Ontario M9C 1B7
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61724 First edition 1998-04 Photovoltaic system performance monitoring Guidelines for measurement, data exchange and analysis Suivi des performances des systèmes photovoltaïques
More informationFLUSH MOUNT INSTALLATION MANUAL
FLUSH MOUNT INSTALLATION MANUAL CONTENTS DISCLAIMER 1 RATINGS 2 MARKINGS 2 CHECKLIST 3 1. ATTACH BASES 4 2. PLACE RAILS 4 3. SECURE LUGS 5 4. SECURE MODULES 5 EXPANSION JOINTS 6 ELECTRICAL DIAGRAM 6 FLASHFOOT
More informationTechnical Assessment Guideline Applicable for the Kiwa KQ Certification Scheme:
Technical Assessment Guideline Applicable for the Kiwa KQ Certification Scheme: Solar products and components Accreditation Kiwa Italia S.p.A. Via Treviso 32/34 31020 San Vendemiano (TV) Italia Tel: +39
More informationIECRE OPERATIONAL DOCUMENT
IECRE OD-401 IECRE OPERATIONAL DOCUMENT Edition 4.0 2019-01-28 Deleted: 3 Deleted: 05 Deleted: 10 IEC System for Certification to Standards relating to Equipment for use in Renewable Energy applications
More informationTest Report. Appliance EMF Testing
Project: 11014506A Date: November 6, 2015 Model: 120V_WWF13NW Test Report On Appliance EMF Testing Copyright 2005 UL LLC UL LLC authorizes the above-named company to reproduce this Report provided it is
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61215 Second edition 2005-04 Crystalline silicon terrestrial photovoltaic (PV) modules Design qualification and type approval This English-language version is derived from the
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60904-2 Second edition 2007-03 Photovoltaic devices Part 2: Requirements for reference solar devices This English-language version is derived from the original bilingual publication
More informationIncident Summary #II (#8165) (FINAL)
Incident Summary #II-727632-2018 (#8165) (FINAL) Incident Date June 26, 2018 Location White Rock SUPPORTING INFORMATION Regulated industry sector Impact Injury Damage Qty injuries 0 Injury description
More informationFIRE-RESISTANCE TEST ON DOWNLIGHT COVERS INSTALLED IN PLASTERBOARD CEILINGS
FIRE-RESISTANCE TEST ON DOWNLIGHT COVERS INSTALLED IN PLASTERBOARD CEILINGS Report number FSP 1290A CSIRO job number LP46ASP3085 Date of issue 30 NOVEMBER 2007 Client EFFICIENCY MATRIX PTY LTD and YOUNGEN
More informationTRANSLUCENT FIRE RATED SYSTEMS
28662 N. Ballard Drive Lake Forest, IL 60045 PHONE (800) 759-6985 FAX (847) 816-0425 TRANSLUCENT FIRE RATED SYSTEMS Committed to Fire Safety QUADWALL CLASS A IS SHOWN IN ACTUAL ASTM E-108 TESTS. ASTM E-108
More informationFood Service Technology Center
Food Service Technology Center IR Energy Habanero HAB-M50 Gas Patio Heater Test Report Application of ASTM Standard Test Method FF2644-07 September 2014 Prepared by: Elan Frantz Trey Young Fisher-Nickel,
More informationPublic Comment No. 2-NFPA [ Section No ]
Page 1 of 13 Public Comment No. 2-NFPA 703-2013 [ Section No. 2.3.1 ] 2.3.1 ASTM Publications. ASTM International, P.O. Box C700, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959. ASTM D 2898, Standard
More informationFire resistance test on fire collars protecting a concrete slab penetrated by services
INFRASTRUCTURE TECHNOLOGIES Fire resistance test on fire collars protecting a concrete slab penetrated by services Test Report Author: Mario Lara Report number: FSP 1601a Date: 11 April 2014 (This report
More informationInstruction Manual. AcuRite Atlas Outdoor Device model 06059
Instruction Manual AcuRite Atlas Outdoor Device model 06059 How It Works Set Up Your AcuRite Atlas AcuRite Atlas is an environmental monitoring station that delivers key information on current outdoor
More informationHeat and Smoke Release of a Ceiling-Installed Speaker
WFCi Project #12051 Heat and Smoke Release of a Ceiling-Installed Speaker Indicative testing conducted in accordance with the test methodology described in UL 2043, Fire test for heat and visible smoke
More informationGuidance Note. 3. Fire Propagation and flame Flame Spread in in Powder Coatings. Abrasion Resistance of Fluoropolymer and polyester Coatings
Guidance Note 3. Fire Propagation and flame Flame Spread in in Powder Coatings Abrasion Resistance of Fluoropolymer and polyester Coatings British Standards British Standard 476 refers to fire tests on
More informationReport Of Surface Burning Characteristics Tests On Samples As Submitted By Tile-diy LLC
Mr. Seth Wentz Tile-diy LLC 1965 International Way Hebron, KY 41048 United States Our Reference: Subject: SV17262/08CA11093 Report Of Surface Burning Characteristics Tests On Samples As Submitted By Tile-diy
More informationSOUTHWEST RESEARCH INSTITUTE
SOUTHWEST RESEARCH INSTITUTE 6220 CULEBRA ROAD 78238-5166 P.O. DRAWER 28510 78228-0510 SAN ANTONIO, TEXAS, USA (210) 684-5111 WWW.SWRI.ORG CHEMISTRY AND CHEMICAL ENGINEERING DIVISION FIRE TECHNOLOGY DEPARTMENT
More informationCLASSIFICATION Constructional Data Report (CDR)
CLASSIFICATION Constructional Data Report (CDR) 1.0 Reference and Address Report Number 100358381SAT-001 Original Standard(s) Fire Test for Heat and Visible Smoke Release for Discrete Products and Their
More informationApplication Note on Reading the Vigilohm IM400 Insulation Monitoring Device Installed in Conext Core XC and XC-NA Series Inverters
Application Note on Reading the Vigilohm IM400 Insulation Monitoring Device Installed in Conext Core XC and XC-NA Series Inverters AP-XC-001-EN Revision B DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, ARC
More informationReport Of Surface Burning Characteristics Tests On Fire Retardant Coating As Submitted By Contego International
January 3, 7 Mr. Danny French Contego International 334 Greyhound Pass West Carmel, IN 4632 Our Reference: Subject: R25382 / 6CA51291 Report Of Surface Burning Characteristics Tests On Fire Retardant Coating
More informationTechnical Training International Textiles Training September 2018 Ellen Roaldi Instructor
Technical Training International Textiles Training September 2018 Ellen Roaldi Instructor www.astm.org ASTM D1230 Flammability of Apparel Textiles Scope: This test method covers the evaluation of the flammability
More informationFire-resistance test on fire collars protecting a concrete slab penetrated by services
INFRASTRUCTURE TECHNOLOGIES Fire-resistance test on fire collars protecting a concrete slab penetrated by services Test Report Author: Chris Wojcik Report number: FSP 1735 Date: 8 September 2016 Client:
More informationTECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION IEC TS 62941 Edition 1.0 2016-01 Terrestrial photovoltaic (PV) modules Guidelines for increased confidence in PV module design qualification and type approval INTERNATIONAL ELECTROTECHNICAL
More information