Select the proper RFID Tag for Harsh Environments. Richard Aufreiter, PM, HID Global
|
|
- Bruno Mitchell
- 6 years ago
- Views:
Transcription
1 Select the proper RFID Tag for Harsh Environments Richard Aufreiter, PM, HID Global
2 An ASSA ABLOY Company The global leader in door opening solutions Operations in more than 70 countries $ 7.5 billion annual sales 20+ years contactless technology development and manufacturing 45+ years manufacturing experience Top recognized brand in access control industry, acquired affiliated product brands employees Over 2 billion RFID products sold
3 How to pick RFID Tags Frequency: LF, HF, UHF Chip / Memory Affixation method: Glue, weld, screw, clamp, plug-in, embed...
4 Main Characteristics of RFID LF (125/134.2 khz) HF (13.56 MHz) UHF ( MHz) Active Tags (2.45 GHz) Data Transfer Rate Memory Capacity Operating Range Anti-Collision Speed n/a or Maintenancefree Operation Water / Humidity Metal Environment or or
5 bw2 How to pick rugged RFID Tags
6 Slide 5 bw2 We need an icon for force/vibration. (These are excellent graphics that clearly/quickly communicate and one slide is missing an icon.) bwegener, 8/21/2012
7 ATEX Zones Picture by: Zones 1 (gas) or 21 (dust) (area in which under normal operation a potentially explosive atmosphere can occasionally form)
8 ATEX Certified Tags Safe for potentially explosive environments E.g. An ATEX certification of II 2G Ex ia IIA T5 Gb means: II all other explosive areas (all except mining) 2 can be used in zones 1 or 21 (area in which under normal operation a potentially explosive atmosphere can occasionally form) G Gas (as opposed to D Dust) Ex ATEX certified ia intrinsic safety (permitted for zone 0) The development of inadmissibly high temperatures, ignition sparks and arcs are avoided due to the restriction of energy in the circuit IIA Explosion group like Propane T5 212 F / 100 C Gb Equipment Protection Level (EPL) = Zone 1 or 21
9 IP 66, 67, 68, 69K IP rating is defined in 2 steps First digit is Solid Particle Protection, where 1 means particles >50mm cannot enter, up to 6 which means dust tight Second digit is for Liquid Protection, where 1 means Dripping water 7 means can be short term submerged under water 8 means can be long term submerged under water (e.g. housing does not assimilate or soak in water over time) IP68 is typically associated with waterproof and tested by submerging the tag for 24h in 1-2m deep water basin
10 IP69K IP68 (aka waterproof ) Tag can be submerged under water continuously for a defined duration IP69K Spray nozzle that is fed with 176 F / 80 C hot water at 8 10 Mpa ( bar) and a flow rate of L/min. The nozzle is held cm from the tested device at angles of 0, 30, 60 and 90 for 30s each. The test device sits on a turntable that rotates once every 12s (5 rpm)
11 Impact Resistance IK rating is defined in EN 62262, measured in Joule Values range from IK00 (not tested) to IK10 Polyamide object for IK 6, steel for IK 7. E.g. IK04: Drop of 200g poyamide object from 9.8 in / 25 cm (0.5J) IK09: Drop of 5kg steel object from 7.8 in / 20 cm (10J) IK10: Drop of 5kg steel object from 15.7 in / 40 cm (20J) Video:
12 Flame Resistance - UL94 Hx Video: UL 94 HB = IEC (former ISO 1210) A specimen is supported in a horizontal position and is tilted at 45. A flame is applied to the end of the specimen for 30 seconds or until the flame reaches the 1 inch mark Material shall stop burning after flame is removed Material shall not melt or leave burning drops Different levels of flame resistance specified (HB, H2, H1, H0) Typically tested on housing material by material vendor
13 Force & Vibration Tags are compressed with a defined force measured in Newton (N) for a defined time (usually 10 sec.) 1 N is the force of Earth's gravity on a mass of about 100 g = ( kg) Most tags are tested for N Force from different sides Vibration IEC tested with shaking table Shock IEC sudden acceleration, deceleration
14 Some Other Tag Tests and many more... Thermal Tests Drop Tests Bending Tests Twist Tests Washing Tests
15 HID Offering in RFID Tags HID covers all major frequencies to suit various applications HID products support chips from all major manufacturers like Swiss engineering combined with HID-owned Malaysian, fully automated, ISO 9001:2008 certified production plant ensures affordable top quality Custom design services help system integrators to create innovative or specialized RFID solutions across the world LF HF UHF
16 Richard Aufreiter Visit us at Cartes Paris, Booth 3F 002
ATEX Explained A brief Introduction
The Trusted Source for Secure Identity Solutions ATEX Explained A brief Introduction January 19, 2016 ATEX Zones Zones 1 (gas) or 21 (dust) (area in which under normal operation a potentially explosive
More informationUnderstanding Hazardous and Explosion-Protection Environments
Understanding Hazardous and Explosion-Protection Environments Explosions occur when a mixture of oxygen and explosive substances develop into explosive gases. When the concentration of a substance in air
More informationGuide for hazardous areas
Guide for hazardous areas 1 Hazardous areas definitions 2 Gas and dust s 3 Temperature classifications 4 Common flammable gases, vapours and dust types 5 Protection concepts ATEX and IECEx 6 Protection
More informationWeighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE
Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE PUE HX5.EX explosion-proof hazardous area indicator ATEX APPROVAL PUE HX5.EX is a cutting-edge weighing indicator, designed to
More informationUL HAZARDOUS LOCATIONS SERVICES
UL HAZARDOUS LOCATIONS SERVICES The international preference in hazardous locations certification for over 100 years ul.com/hazloc Explosive Gas Atmospheres Class I Division S Includes flammable gases,
More informationHOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper
HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper How Limit and Basic Switches Can Stop Machines from Going Boom White Paper sensing.honeywell.com 2 Abstract In hazardous
More informationAiro Wireless Intrinsically Safe White Paper. Written By: David Schmitt
Airo Wireless Intrinsically Safe White Paper Written By: David Schmitt Intrinsically Safe Cell Phone/Smartphone/PDA Intrinsically Safe (IS) is a protection certification for safe operation with electronic
More informationIntrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20
Electronic Pressure Measurement Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Applications Chemical, Petrochemical
More informationCA 134. Piezoelectric accelerometer. IECEx NEPSI TIIS KGS. » From the Vibro-Meter product line» Vibration monitoring over a wide temperature
FEATURES» From the Vibro-Meter product line» Vibration monitoring over a wide temperature range, including cryogenic temperatures» Differential output» Hermetically welded» Certified for use in potentially
More informationATEX - ATmosphere EXplosive
ATEX - ATmosphere EXplosive 153 DIRECTIVE 94/9/CE (ATEX= ATMOSPHERE EXPLOSIVE) OF THE EUROPEAN PARLIAMENT AND COUNCIL (MARCH 23, 1994): IMPACT ON LIGHTING FIXTURES APPLICATIONS Polycarbonate and steel
More informationIntrinsically safe acoustic emission equipment opens the door to permanent monitoring applications in the oil and gas industry
18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa Intrinsically safe acoustic emission equipment opens the door to permanent monitoring applications in the oil and
More informationATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC
Quick Introduction to TÛV Denmark TÜV Denmark - is a part of the TÜV NORD Group a global Organisation f Certification and Inspection of: Quality Management Systems, Products, Processes and Qualification
More informationVSD AND SS DRIVING ATEX MOTORS February 2014
VSD AND SS DRIVING ATEX MOTORS February 2014 1 Introduction to ATEX 2 ATEX motor designation 3 VSD Sample Solutions 4 SS descriptions Introduction to ATEX EU territory define the use of electrical equipment
More informationSIMATIC Sensors. RFID systems SIMATIC RF640T. SIMATIC RF640T Operating Instructions. Operating Instructions 05/2007 A5E
Operating Instructions 1 SIMATIC Sensors RFID systems 0044 II 2 G Ex ib IIC T6 bis T3 II 2 D Ex ibd 21 T140 C Operating Instructions 05/2007 A5E00909183-02 Safety Guidelines This manual contains notices
More informationTest Methods for Consideration Into Radio Standard
Test Methods for Consideration Into Radio Standard Jason Allen March 20,2013 Test Methods for Consideration Into Radio Standard Reviewed many current NFPA standards including: NFPA 1971- Structural and
More informationmanual addendum DELPHI Ex
manual addendum DELPHI Ex II 2G Ex eb IIC T4 Gb II 2D Ex tb IIIC T135 C IP65 Db Tamb=-20 +40 C Reference list: Norm (last issue) Title Dir. 2014/34/UE EN 60079-31 EN60079-0 EN60079-7 Equipment and Protective
More informationDual certification! Air handling units for potentially explosive atmospheres
Dual certification! Air handling units for potentially explosive atmospheres X-CUBE Ex A certified safety product The air handling unit with dual ATEX certification ATEX directive 2014/34/EU applies to
More informationSONAPHONE E. ATEX Certificated for the Use in Areas with Risk of Explosion. Features:
SONAPHONE E ATEX Certificated for the Use in Areas with Risk of Explosion Features: For use in potentially explosive atmospheres Integrated data logger Multifunctional testing device Easy handling Fields
More informationNext Generation Corporate Identity. Robert Jansson End user and consultant business manager Northern Europe
Next Generation Corporate Identity Robert Jansson End user and consultant business manager Northern Europe ASSA ABLOY HID Global Global leader in door opening solutions Formed in 1994 Dedicated to satisfying
More informationATEX, NOMENCLATURE AND CODING
Technical Notes ATEX, NOMENCLATURE AND CODING The intent of this technical note is approach to the user to the ATEX normative. For this we will begin defining, what is an explosive atmosphere, what are
More informationHazardous Areas - EXPLOSIONPROOF SOLENOIDS
Hazardous Areas - EXPLOSIONPROOF SOLENOIDS SOME HISTORY The classification of hazardous areas into zones established the level of protection required for electrical equipment installed in explosive gas
More informationTrusted worldwide since 1989 INTRINSICALLY SAFE RANGE
Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE Trusted worldwide We are now in our 28th year designing and manufacturing portable rechargeable lighting systems. Our main objective is to offer high
More informationSIMATIC RF640T Gen 2 1. SIMATIC Sensors. RFID systems SIMATIC RF640T Gen 2. Operating Instructions. Siemens 05/2009 J31069-D0197-U001-A2-7618
1 SIMATIC Sensors RFID systems Operating Instructions 05/2009 J31069-D0197-U001-A2-7618 Siemens Legal information Warning notice system This manual contains notices you have to observe in order to ensure
More informationAdditional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.
Additional Operating Instructions SITRANS F Vortex flowmeters Ex-i Edition 09/2018 CONTENTS 1 Safety instructions 3 1.1 General notes... 3 1.2 EU conformity... 3 1.3 Approval according to the IECEx scheme...
More informationREGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC
EUROPEAN ATEX DIRECTIVE > European Directive 2014/34/EU ATEX Directive 2014/34/EU is a "new approach" directive that applies to protective systems against explosions as well as all equipment used in or
More informationOverview of Hazardous Locations as They Relate to Solenoid Valves
Overview of Hazardous Locations as They Relate to Solenoid Valves Defined: Hazardous Location - "where fire or explosion hazards may exist due to flammable gases or vapors, flammable liquids, combustible
More informationGuide to Hazardous Location Approvals:
Selection Guide Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches Introduction There are many considerations when selecting a switch to be used in hazardous areas. In addition
More informationGuide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches
Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches A Selection Guide Introduction There are many considerations when selecting a switch to be used in hazardous areas. In
More informationSmartLine. RMA803 SmartLine Remote Fieldbus Indicator Specification 34-ST-03-90, December Technical Information.
SmartLine Technical Information RMA803 SmartLine Remote Fieldbus Indicator Specification 34-ST-03-90, December 2015 Introduction The Honeywell RMA803 is a Foundation Fieldbus remote indicator suitable
More informationSeat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.
ATEX SOLUTIONS In order to apply a single level for health and safety requirements and to overcome barriers of trade within Europe, national regulations for explosion prevention were harmonized in 1975
More informationCopy Right By: Thomas T.S. Wan
Chapter 23 Motor and Starter Copy Right By: Thomas T.S. Wan 温到祥著 Sept. 3, 2008 All rights reserved Electric Motors All the motors are to be designed and constructed in accordance with NEMA code. Electric
More informationCE110I. Piezoelectric accelerometer with integrated electronics. IECEx
Piezoelectric accelerometer with integrated electronics FEATURES» From the Vibro-Meter product line» Designed for medium temperature industrial applications: 55 to 115 C» Sensitivity: 100 mv/ g» Frequency
More informationDrive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors
Drive Technology \ Drive Automation \ System Integration \ Services *23511257_0817* Inquiry Forms for Explosion-Proof Gearmotors Edition 08/2017 23511257/EN SEW-EURODRIVE Driving the world Inquiry forms
More informationBeamex. Calibration White Paper. Calibration in hazardous areas
Beamex Calibration White Paper info@beamex.com Calibration in hazardous areas This article discusses calibration in hazardous areas and what everyone needs to be aware of before entering into a hazardous
More informationATEX, NOMENCLATURE AND CODING
ATEX, NOMENCLATURE AND CODING The intent of this technical note is approach to the user to the ATEX normative. For this we will begin defining, what is an explosive atmosphere, what are ATEX, as well as
More informationUser s Manual YTA610 and YTA710 NEPSI Certification
User s Manual YTA60 and YTA70 NEPSI Certification [Option code: /NS, /NS5 and /NF] st Edition . INTRODUCTION Thank you for purchasing the YTA60 and YTA70 Temperature transmitters. This manual contains
More informationBeamex Calibration White Paper. Calibration in hazardous areas
Beamex Calibration White Paper info@beamex.com Calibration in hazardous areas This article discusses calibration in hazardous areas and what everyone needs to be aware of before entering into a hazardous
More informationHow Limit Switches Can Stop Machines from Going Boom
How Limit Switches Can Stop Machines from Going Boom A Honeywell White Paper Safety is one of the top criteria when selecting a limit switch for hazardous location environments. In many cases, these switches
More informationINTRINSICALLY SAFE LIGHTING RANGE
Trusted worldwide since 1989 INTRINSICALLY SAFE LIGHTING RANGE SAFE PORTABLE RECHARGEABLE AC MAINS Trusted worldwide We are now in our 28th year designing and manufacturing portable rechargeable lighting
More informationCirculation heaters for ATEX/IECEx hazardous areas or in non-atex version
for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI500EN 09/2017
More informationUL 94 Flammability Ratings: Introduction
UL 94 Flammability Ratings: Introduction UL intends this standard to serve as a preliminary indication of a plastics acceptability for use as part of a device or appliance with respect to its flammability.
More informationInductive slot sensor
0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 4 mm
0102 Model Number Features 4 mm non-flush Accessories BF 12 Mounting flange, 12 mm Technical Data specifications Switching element function NAMUR, NO Rated operating distance s n 4 mm Installation non-flush
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate IECEx
More information120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable
120W Hazardous Location LED Fixture - 12-24V DC - Modbus TCP/IP - Network Controlled - Dimmable Part #: HAL-ANC-60-120W-ITG-LED-DIMM-1224 Page: 1 The Larson Electronics HAL-ANC-60-120W-ITG-LED-DIMM-1224
More informationAn Introduction to the IECEx System and IECEx Scheme Certification Processes IECEx Secretariat January 2018
INTERNATIONAL ELECTROTECHNICAL COMMISSION An Introduction to the IECEx System and IECEx Scheme Certification Processes IECEx Secretariat January 2018 IEC:2007 Pillars of the IEC building Standards Development
More informationErik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories
Hazardous Locations: Understanding the Basics of Global Compliance Requirements Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories DISCLAIMER/ TERMS OF USE: THE INFORMATION
More informationPYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white
. TECHNICAL DATA LIGHT FITTING REFLECTOR Polycarbonate tube of 4 mm. thickness Laquered steel painted white END CAPS Aluminium 2030 (polyester paint RAL 7047) POWER SOURCE LAMP TYPE 220-240V, 50/60Hz T8
More information25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL
25W Hazardous Location Integrated LED Light Fixture - 3294 Lumens - Low Profile - ATEX IEC CSA UL Part #: HAL-19-25W-ITG-LED Page: 1 The Larson Electronics HAL-19-25W-ITG-LED 25 Watt Explosion Proof Low
More informationALTAIR 5X Multigas Detector Product Specification
ALTAIR 5X Multigas Detector Product Specification PHYSICAL CHARACTERISTICS Gas delivery Size, pumped unit without IR Size, pumped unit with IR Weight Handling Case material Environmental protection Display
More informationSmart encoders & actuators
Declaration of Conformity The manufacturer: LIKA ELECTRONIC SRL 36010 Carrè (VI) - Italy hereby declares that the following products (only when correctly assembled): XAC8018/1PB-14 XAC8018/1CB-14 XAC8018/1FD-14
More informationBC9700 series High Power LED Explosion Proof Light
BC9700 series High Power LED Explosion Proof Light Characteristics IECEx ATEX LM79 LM8 IP 66 Ta 0/55 Ta -0 Application Zone,zone ;zone,zone Suitable for Low installation height in Moist corrosive environment,such
More informationIntrinsic Safety. Intrinsically Safe Solutions. Accurate Weighing in Hazardous Areas
Intrinsic Safety Intrinsically Safe Solutions Accurate Weighing in Hazardous Areas Accidents in hazardous areas can have dramatic consequences for businesses in terms of both human life and profit. Intrinsically
More informationOfficine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0
Officine Meccaniche M.A.M. Apparecchiature Antideflagranti DOCUMENT IS-EJB-A-14 rev. 0 Instructions Flameproof enclosures EJB../W series for command, control, signaling and/or automation Emission date:
More informationRE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES
Limassol 20 th August, 2015 RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES This document is intended to provide clarification on the use of FirePro Condensed Aerosol Generators in Potential Explosive
More informationI.S. Interfaces. for the Process Industry. display. i.s. interface. isolation. temperature. universal
I.S. Interfaces for the Process Industry display i.s. interface isolation temperature universal 2 Outstanding I.S. Signal PR electronics is one of the world s leading manufactures of intrinsically safe
More informationMachine Protection Door Albany RP300. ASSA ABLOY Entrance Systems
Machine Protection Door Albany RP300 ASSA ABLOY Entrance Systems Albany RP300 Rapid opening and closing ensures short cycle times up to 5 cycles per minute High reliability even after years of high numbers
More informationFlameproof Manual Call Points Series MCP
> Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied
More informationPROXIMITY CARDS. RFID Clamshell Thick Smart Card. Proximity ISO Smart Card, 125 khz. HID Proximity II ISO Smart Card. Mifare 1K Proximity Card
PROXIMITY CARDS Proximity ISO Smart Card, 125 khz RFID Clamshell Thick Smart Card Mifare 1K Proximity Card HID Proximity II ISO Smart Card Used in schools, banks, medical insurance companies, government
More informationSafety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS
Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS 10.0008 Ex td A20, A20/21, A20/22, A21 IP66 T 0044 37675 Contents 1 Area of applicability 3 2 General information 3 2.1 Zone 20 instruments
More informationAtmosphere. Introduction. explosion when exposed to a source of ignition. and IEC standards as follows:
ATEX enclosures Enclosures for explosive atmospheres Introduction PB500061-26 PB500060-47 PB500059-52 Oxygen Heat Chain reaction Fuel Explosive atmosphere Potentially explosive atmospheres: important information
More informationI.S. Interfaces. for the Process Industry. display. i.s. interface. isolation. temperature. universal
I.S. Interfaces for the Process Industry display i.s. interface isolation temperature universal 2 Outstanding I.S. Signal PR electronics is one of the world s leading manufacturers of intrinsically safe
More informationDuct heaters for ATEX/IECEx hazardous areas or in non-atex version
for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI200EN 09/2017
More informationManual Power relay SR853
Manual Power relay SR853 Product types SR853.8.x.x, Rev. 1 SR853 manual page2 The symbols WARNING, CAUTION, NOTE This symbol warns of a serious hazard. Failure to observe this warning may result in death
More informationJAMIN 100. Compact impervious luminaire for ATEX zones. Zones 2, 21, 22
JAMIN 100 Compact impervious luminaire for ATEX zones Zones 2, 21, 22 JAMIN 100 ATEX LIGHTING THEY TRUST US: ACETEX CHIMIE, ADISSEO, ADNATCO (Abu Dhabi National Tanker Company), Airbus, BRITISH PETROLEUM,
More informationTechnical Data. General specifications. Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm
More informationCCTV Portfolio. Phoenix Explosion-proof Range
CCTV Portfolio Phoenix Explosion-proof Range Siemens AB - 2015 Agenda Introduction What is ATEX all about? Basics Quick facts Flammability risk Suitability Marking Protection types Phoenix Product Range
More informationImmersion heaters for ATEX/IECEx hazardous areas or in non-atex version
for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI100EN 09/2017
More informationFACTORY AUTOMATION EXPERIENCE HYGIENIC DESIGN SENSORS FOR THE FOOD AND BEVERAGE INDUSTRY
FACTORY AUTOMATION EXPERIENCE HYGIENIC DESIGN SENSORS FOR THE FOOD AND BEVERAGE INDUSTRY PEPPERL+FUCHS YOUR COMPETENT PARTNER Pepperl+Fuchs GmbH, headquartered in Mannheim, is a leading developer and manufacturer
More informationLIGHTING in Hazardous (Classified) Locations
LIGHTING in Hazardous (Classified) Locations Topics What is a Hazardous Location? Who Classifies Hazardous Areas? Common Hazardous Location Areas Mechanics of Gas & Vapor Explosions Lighting for Hazardous
More informationTrusting in experience. Relying on expertise. Focusing on solutions. Bebco EPS Purge+Pressurization Product Overview
Trusting in experience. Relying on expertise. Focusing on solutions. Bebco EPS Purge+Pressurization Product Overview About Us Automation is our world. A perfect application solution is our goal. A willingness
More informationGuide to Intrinsically Safe Portable Radios
Guide to Intrinsically Safe Portable Radios An overview of common IS standards www.taitradio.com GUIDE TO INTRINSICALLY SAFE PORTABLE RADIOS SUMMARY The development of equipment for explosive atmospheres
More informationSAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508
Open-Path Gas Detection System SAFEYE XENON 700 Hydrocarbons and ethylene detection Heated optics 10-year Warranty for the Xenon flash bulb SIL 2 according to IEC 61508 Certifications The Fixed Gas Detection
More informationWireless Access Control Light Commercial Lockset. WIACCOCAT - Wireless Access Control Light Commercial Lockset Catalogue_
Wireless Access Control Light Commercial Lockset WIACCOCAT - Wireless Access Control Light Commercial Lockset Catalogue_0915-2.indd 1 14/09/2015 2:04:08 p.m. Access Control Common access points, and emergency
More information40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated
40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated Part #: HALD-24-1X40CPR-LED-V2 Page: 1 The Larson Electronics HALD-24-1X40CPR-LED-V2 Explosion Proof LED Fixture provides
More informationARCHITECTURAL AND ENGINEERING SPECIFICATION
ARCHITECTURAL AND ENGINEERING SPECIFICATION Access Control System ACTpro Vanderbilt Industries, Clonshaugh Business and Technology Park, Dublin, D17 KV84, Ireland TABLE OF CONTENTS PART 1 GENERAL 1.1 System
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60079-7 Edition 5.0 2015-06 Explosive atmospheres Part 7: Equipment protection by increased safety ''e'' INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 29.260.20 ISBN 978-2-8322-2710-7
More informationAdditional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.
Additional Operating Instructions SITRANS F Vortex flowmeters Ex-d Edition 09/208 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4
More informationGLOBAL ENCLOSURE STANDARDS WITHIN THE ELECTRICAL INDUSTRY
GLOBAL ENCLOSURE STANDARDS WITHIN THE ELECTRICAL INDUSTRY Industry standards for electrical enclosures exist to promote safety, encourage design efficiency and define minimum levels of product performance.
More informationThe R. STAHL Technology Group Worldwide Success with Competence and Customer Support
The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The entrepreneurial basis of the R. STAHL Technology Group follows a long tradition. The product range is aimed at specialised
More informationS T R I T T & P R I E B E I N C.
Equipment Enclosure Comparisons Type of Enclosure European - Area of use Designation Standard IEC - Area of use Designation Standard USA - Area of use Designation Standard Flameproof Enclosure An enclosure
More information25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC
25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame - 120-277V AC Part #: EXHL-TRN-LE1-1227 Page: 1 Made in Texas The EXHL-TRN-LE1-1227 from Larson Electronics is an Explosion
More informationPressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications
Force Pressure Temperature Switch Pressure sensors Ex ia I / IIC T6 acc. to ATEX with internal diaphragm with front flush diaphragm Accuracy: 0,25% and 0,5 % Standard output: 4...20 ma; 2-wire system Description
More informationSELECTION, INSTALLATION & TESTING OF ELECTRICAL EQUIPMENTS IN HAZARDOUS AREA
Training Title SELECTION, INSTALLATION & TESTING OF ELECTRICAL EQUIPMENTS IN HAZARDOUS AREA Training Duration 5 days Training Venue and Dates REF EE019 Selection, Installation & Testing of Electrical Equipments
More informationTPPL TUBULAR PROFESSIONAL PERFORMANCE LIGHTING SMART LIGHTING FOR HARSH ENVIRONMENTS
TPPL TUBULAR PROFESSIONAL PERFORMANCE LIGHTING SMART LIGHTING FOR HARSH ENVIRONMENTS ATEX DIRECTIVES The ATEX directives 2014/34/EU & 1999/92/EC are commonly referred to as the two European Directives
More informationOPTIBAR P 1010/2010 C Supplementary instructions
OPTIBAR P 1010/2010 C Supplementary instructions Pressure transmitter Equipment category II 1G / Ga, II 1D / Da in protection type intrinsic safety Exi KROHNE CONTENTS OPTIBAR P 1010/2010 C 1 Safety instructions
More information26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE
26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE Part #: EPL-LP-12-LED Page: 1 The EPL-LP-12-LED from Larson Electronics is a Low Profile Explosion Proof
More information[ TECHNOLOGY ] and does this definition affect a burner.
[ TECHNOLOGY ] JBD-11,500-G type burner for natural gas ATEX, EExd Zone 2. For combined cycle power plant in Riga Latvia. Aitor Fernández Project Engineer Automation Department Head afernandez@emcombustion.es
More information1. GENERAL TECHNICAL INFORMATION
1. GENERAL TECHNICAL INFORMATION 1.1 EXPLOSIVE ATMOSPHERES: Every time that dangerous quantities and concentration of flammable gas, vapors mixture or dust clouds exists, risk of explosions may arise.
More informationSafety instructions VEGAPULS 64
Safety instructions Intrinsic safety "i" 4 20 ma/hart - two-wire Document ID: 53001 Contents 1 Area of applicability... 3 2 Important specification in the type code... 3 3 Different ignition protection
More informationFact Sheet No.4. CompEx Modules EX01R to EX04R for Gas and Vapour Environments
Fact Sheet No.4 CompEx Modules EX01R to EX04R for Gas and Vapour Environments Module Breakdown EX01R: EX02R: EX03R: EX04R: The preparation & installation of Ex d, n, e and p equipment in potentially explosive
More information150 Watt Explosion Proof LED Light - 5' Tall Base Stand Mount - 24 Inch Stand - Class I Div 1 C&D
150 Watt Explosion Proof LED Light - 5' Tall Base Stand Mount - 24 Inch Stand - Class I Div 1 C&D Part #: EPL-24BS-5FT-1X150LED-100 Page: 1 Made in Texas The EPL-24BS-5FT-1X150LED-100 Explosion Proof LED
More informationSelecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals
Selecting a Safe Tank Gauging Product Understanding Hazardous Area Definitions for Equipment Approvals Hazardous Area Approvals A Worldwide Requirement There are many environmental considerations within
More informationEUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU
EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU GENERAL The accidental ignition of an atmosphere containing a large quantity of gas, vapour, mists and/or dust may cause an explosion. Specific
More informationOPTIBAR DP 7060 Supplementary Instructions
OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,
More informationDräger Polytron 5100 EC Detection of toxic gases and vapors
Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen. It uses a high performance
More informationAustralian/New Zealand Standard
AS/NZS 60079.0:2012 IEC 60079-0, Ed. 6.0 (2011) AS/NZS 60079.0:2012 Australian/New Zealand Standard Explosive atmospheres Part 0: Equipment General requirements AS/NZS 60079.0:2012 This Joint Australian/New
More informationAutomation at first hand. years
Automation at first hand. www.ifm.com WARRANTY years on ifm products Global presence and competent advice on site Worldwide direct and personal service: Whether via telephone, e-mail or in a personal
More informationElectrical Installations Design, Selection, Erection and Inspection
IECEx International Conference 2018 Jakarta, Indonesia Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2018 Jakarta, Indonesia Peter Thurnherr thuba Ltd.,
More information