Champ-Pak Wall Pack Luminares

Size: px
Start display at page:

Download "Champ-Pak Wall Pack Luminares"

Transcription

1 Champ-Pak Wall Pack Luminares Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II, Groups F, G Cl. III & Simultaneous Presence Marine & Wet Locations Enclosure Type 4X, IP66 The first low-profile wall pack designed specifically for hazardous areas. The Cooper Crouse-Hinds Champ-Pak Wall Pack Luminaire is ideal for low-profile mounting in hazardous and industrial environments. In fact, it is suitable for any area with adverse conditions such as dust, dirt, moisture, vibration, high-pressure hose downs, and high thermal ambients. Its precisely designed glass refractor minimizes fixture depth while providing uniform, glare-free illumination. Unique compact shallow-profile design mounts virtually anywhere Side-hinged cover with two-screw closing for easy installation and maintenance Gray Corro-free epoxy powder coated two-piece housing provides superior corrosion resistance Unique stainless steel wire guard accessory attaches without any additional hardware for easy installation and maintenance Glass refractor provides uniform light distribution to eliminate glare Vertical lamp design provides even lamp heat distribution for cooler operation, providing expanded hazardous area suitability Silicone gaskets make luminaire suitable for enclosure Type 4X, marine, and IP66 environments Available in two different conduit entry configurations to permit flexible installation and mounting Four 3 /4" NPT hubs, one on each side Two 1 /2" NPT hubs on bottom for feed-through applications Applications: Indoor and outdoor wall mounting or vertical surface mounting where minimal fixture depth is required in: Manufacturing plants and heavy industrial facilities Industrial process facilities such as refineries, chemical, petrochemical, pharmaceutical, and production platforms Waste or sewage treatment plants Offshore, dockside, and harbor installations For security and safety lighting in industrial facilities For lighting of loading docks, tunnels, and stairways For marine, wet location, hose down, and corrosive environments Additional Features and Benefits: Variety of lamp types and wattages HID, fluorescent, and induction to meet specific lighting needs High power-factor ballasts (+90%) are standard, which allow more luminaires per circuit Up to 65 C ambient suitability on select lamp types and wattages; ambient suitability of +40 C is standard; allows for installation in higher ambient environments commonly found in industrial facilities Low ambient starting capability (to - 40 C) perfect for colder climates Shock-absorbing HID mogul base lamp socket cushions lamp, improves lamp life in harsh environments Compact fluorescent emergency luminaire provides 90 minutes of lighting during power outages, meeting UL924 and Life Safety Code Cost-effective induction lamp system provides extra long lamp life up to 100,000 hours; reaches full illumination immediately, providing crisp, white light NEC/CEC restricted breathing construction is available to provide cooler temperature classes (T codes) for expanded hazardous area suitability Simplified method for compliance to NEC restricted breathing conduit sealing requirements makes installation easier US: CAN: Copyright 2011 Cooper Crouse-Hinds 1085

2 Champ-Pak Wall Pack Luminares Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II, Groups F, G Cl. III & Simultaneous Presence Marine & Wet Locations Enclosure Type 4X, IP66 Certifications and Compliances: Luminaires For Use With ANSI Lamps (Mogul Base): UL/cUL Listed NEC and CEC Division 2 and Zone 2 Restricted Breathing Division 2 and Zone 2 (suffix S826) Class II, Groups F, G Class III Simultaneous Presence Certified for IEC Zone 2 (suffix S826TB) Wet Locations; Marine Locations; Enclosure Type 4X; IP66 UL Standards: 844 Hazardous (Divisions Classified) Locations 1598 Luminaires 1598A Luminaires for Marine Vessels 924 Emergency Lighting (Fluorescent Emergency Luminaire) CSA Standards: C22.2 No. 9 and 137 CAN/CSA-E :02 IEC Standards: Standard Materials: Fixture housing and door frame assembly copper-free aluminum External hardware stainless steel Refractor lens borosilicate glass Gasket silicone Reflector aluminum light sheet Wire guard stainless steel Standard Finishes: Aluminum Corro-free epoxy powder coat Stainless steel natural Ratings (Electrical/Size): Sources/Wattages High-pressure sodium (HPS) mogul base 50, 70, 100 & 150 Metal halide (MH) mogul base 70, 100 & 150 Compact fluorescent 26, 32, 42, 52, 64 & 84 Emergency fluorescent 26 Induction 55 & 85 Voltages HID Standard-Voltage Ballasts Dual tap (120 & 277 V, 60 Hz for 50 W HPS only) prewired at 277 V Multi-tap (120, 208, 240 & 277 V, 60 Hz) prewired at 277 V Tri-tap (120, 277 & 347 V, 60 Hz) prewired at 347 V 120 V, 60 Hz 480 V, 60 Hz Fluorescent Standard Voltage Ballasts V, Hz 120 V, 50 Hz (for Canada only) 347 V, 60 Hz (for Canada only) Induction Standard Voltage Ballasts 120 V, Hz (also 120 V DC) 230 V, Hz (also 240 V DC) HID Optional Voltage Ballasts 220 V, 50 Hz 220 V, 60 Hz 240 V, 50 Hz Fluorescent Optional Voltage Ballasts (Consult Factory) 125 V DC 12 V DC 24 V DC Isolated Ballasts And Specials (Consult Factory) 208 V, 60 Hz CWI Isolated Ballast 240 V, 60 Hz CWI Isolated Ballast 480 V, 60 Hz CWI Isolated Ballast Conduit Entries Four 3 /4" NPT entries, one on each side, top and bottom (3 plugged) Two 1 /2" NPT entries on bottom for feed-through (1 plugged) Metric entries consult factory US: CAN: Copyright 2011 Cooper Crouse-Hinds

3 Champ-Pak Wall Pack Luminares Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II, Groups F, G Cl. III & Simultaneous Presence Marine & Wet Locations Enclosure Type 4X, IP66 Ordering Information HID Luminaires: Hub Size Lamp Watts Cat. # High-Pressure Sodium Four 3 /4" NPT (one each side) CPMVS2W Two 1 /2" NPT (on bottom) CPMVS1W050 Four 3 /4" NPT (one each side) CPMVS2W070 Two 70 /2" NPT (on bottom) CPMVS1W070 Four 3 /4" NPT (one each side) CPMVS2W100 Two 100 /2" NPT (on bottom) CPMVS1W100 Four 3 /4" NPT (one each side) 150 CPMVS2W150 Two 1 /2" NPT (on bottom) (for 55 V lamp) CPMVS1W150 Metal Halide Four 3 /4" NPT (one each side) CPMVM2W070 Two 70 /2" NPT (on bottom) CPMVM1W070 Four 3 /4" NPT (one each side) CPMVM2W100 Two 100 /2" NPT (on bottom) CPMVM1W100 Metal Halide Pulse Start Four 3 /4" NPT (one each side) CPMVM2W150 S Two 1 /2" NPT (on bottom) CPMVM1W150 S828 To complete Catalog Number, add Voltage and Option suffix(es). Voltage Suffixes: NEC/UL Voltage (60 Hz) Dual Tap Multi Tap Suffix /DT /MT /120 /480 CEC (CSA/cUL) Voltage (60 Hz) Dual Tap Tri Tap 120 Suffix /DT /TT /120 50W HPS is available only with suffix /DT. Ordering Information Induction Luminaires With Lamp (100,000 hours): Hub Size Four 3 /4" NPT (one each side) Two 1 /2" NPT (on bottom) Four 3 /4" NPT (one each side) Two 1 /2" NPT (on bottom) Voltage Suffixes: Lamp Watts Cat. # 55 CPMVIG2W055 CPMVIG1W CPMVIG2W085 CPMVIG1W V (also 120 V DC) 230 V (also 240 V DC) Voltage (50 60 Hz) (50 60 Hz) Suffix /120 /230 Ordering Information Fluorescent Luminaires: Hub Size Four 3 /4" NPT (one each side) Two 1 /2" NPT (on bottom) Four 3 /4" NPT (one each side) Two 1 /2" NPT (on bottom) Four 3 /4" NPT (one each side) Two 1 /2" NPT (on bottom) Four 3 /4" NPT (one each side) Two 1 /2" NPT (on bottom) Four 3 /4" NPT (one each side) Two 1 /2" NPT (on bottom) Four 3 /4" NPT (one each side) Two 1 /2" NPT (on bottom) Voltage Suffixes: Lamp Watts Cat. # 26 (one 26 W lamp) CPMVF2W026 CPMVF1W (one 32 W lamp) CPMVF2W032 CPMVF1W (one 42 W lamp) CPMVF2W042 CPMVF1W (two 26 W lamps) CPMVF2W052 CPMVF1W (two 32 W lamps) CPMVF2W064 CPMVF1W (two 42 W lamps) CPMVF2W084 CPMVF1W084 NEC/CEC (UL, CSA, cul) CEC (CSA, cul) Voltage V (50 60 Hz) 347 V (60 Hz) Suffix /UNV /347 Ordering Information Fluorescent Emergency Luminaires Continuous Operation: Hub Size Four 3 /4" NPT (one each side) Two 1 /2" NPT (on bottom) Voltage Suffixes: Lamp Watts Cat. # 26 (one 26 W lamp) CPMVFB2W026 CPMVFB1W026 NEC/CEC (UL, CSA, cul) CEC (CSA, cul) Voltage V (50 60 Hz) 120 V (60 Hz) 347 V (60 Hz) Suffix /UNV /120 CAN /347 Compelling reasons to choose the new Champ induction luminaire as the light source for industrial and hazardous locations include: Crisp, white light (80+ color rendering index) provides increased safety by clearly illuminating signs, instrument panels, equipment, and more with vibrant natural colors Up to 100,000 hours of lamp life minimizes routine maintenance costs; if you operate this luminaire for 24 hours, 7 days a week, you will not need to change the lamp for up to 11 years! Instant illumination no waiting for lamp warm-up time; increases productivity and safety Delivers the best possible luminaire temperature rating T6 (85 C) when used with the Champ restricted breathing option; ideal for hazardous areas where a low ignition temperature is required Starts in low temperatures as low as -40 C US: CAN: Copyright 2011 Cooper Crouse-Hinds 1087

4 Champ-Pak Wall Pack Luminares Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II, Groups F, G Cl. III & Simultaneous Presence Marine & Wet Locations; Enclosure Type 4X, IP66 Options: Description Suffix Ballast-Gard starter cut-out switch... BG Not available with IR or QTZ options Factory Assembled with Lamp Installed... FA Instant Restrike... IR Not available with BG or QTZ options Guard Factory Installed on Luminaire... P (Guard suffix follows wattage designation, e.g., CPMVS2W100P/MT) Quartz Auxiliary... QTZ Fused...S658* Not available with CPMVIG and CPMVFB luminaires Not suitable for marine applications Restricted Breathing Construction (AEx nr, Ex nr)... S826 Certified For IEC Zone 2 (Ex nr) (UL Classified to the IEC Standard)... S826TB Furnished with: 4 mm 2, 3-point terminal block Crimp internal wiring connections P55 guard V2PC Photocell Factory Installed 120 V, Hz... /V2PC V, Hz... /V2PC V, Hz... /V2PC27 Optional Voltage Ballasts for HID Luminaires 220 V, 50 Hz... / V, 60 Hz... / V, 50 Hz... / Optional Voltage Ballasts for Fluorescent Luminaires (Consult Factory) 125 V DC... /125 VDC 12 V DC... /12 VDC 24 V DC... /24 VDC Isolated Ballast for HID Luminaires (Consult Factory) 208 V, 60 Hz... /208CWI 240 V, 60 Hz... /240CWI 480 V, 60 H... /480CWI *When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. TEFLON is a registered trademark of E.I. dupont Co. Accessories: (Order Separately) Description Cat. # Photocell For Field Installation 120 V, Hz V2PC V, Hz V2PC V, Hz V2PC27 In Canada, use factory-installed photocell only. Stainless Steel Wire Guard P55 Dimensions (In Inches): Note: Approximate weight less guard 28 lbs. P55 guard 0.5 lbs US: CAN: Copyright 2011 Cooper Crouse-Hinds

5 Champ-Pak Wall Pack Luminares Photometric Data CPMV Photometric Data Luminaire With Refractor Less Wire Guard CPMVS2W150 Lamp: 150 W/E23-1 /2 Clear High Pressure Sodium (HPS) Luminaire With Refractor Less Wire Guard CPMVM2W150-S828 Lamp: 150 W/ED28 Clear Pulse Start Metal Halide For additional photometric data, contact Cooper Crouse-Hinds. US: CAN: Copyright 2011 Cooper Crouse-Hinds 1089

6 Champ-Pak Wall Pack Luminares Photometric Data Luminaire With Refractor Less Wire Guard CPMVF2W084 Lamps: (2) PL-T 42W/30/4P Compact Fluorescent For additional photometric data, contact Cooper Crouse-Hinds US: CAN: Copyright 2011 Cooper Crouse-Hinds

7 Champ-Pak Wall Pack Luminares Temperature Performance Data Temperature Performance Data: Ambient Watts Temp. C HIGH PRESSURE SODIUM 50 Class I Division 2 and Zone 2 Standard Product Restricted Breathing AEx nr/ex nr Option S826 Class II and Class III Simultaneous Presence Class I/Class II (Gas and Dust Present in the Same Area) Standard Product Suitable for Division 2/Class II Restricted Breathing AEx nr/ex nr Option S826 Suitable for Division 2 or Zone 2 and Class II 40 T3A T6 T5 T3A/T5 T T3A T6 T4A* T3/T4A* T4* * T3 T T3A T6 T5 T3A/T5 T T3A T * T3 T T2C T5 Consult Factory for Class II Suitability with 90 55* T2C T4 105 C Supply Wire T2B T4 105 METAL HALIDE 40 T3C T6 T5 T3C/T5 T T3C T * T3C T T3 T PS (S828) 40 T2D T5 105 COMPACT FLUORESCENT T3B T6 T6 T3B/T6 T (347 V) 55 T3A T T3 T T3B T6 T6 T3B/T6 T T3A T (347 V) 40 T3 T ( V) 40 T3B T6 T6 T3B/T6 T (347 V) 55 T3A T T3 T T3 T6 T6 T3B/T6 T T3 T T3 T6 T6 T3/T6 T T3 T T2C T6 90 EMERGENCY FLUORESCENT 26 40* T3B T6 75 Supply Wire Temp. C INDUCTION 55 40* T2D T6 T6 T * T2D T * T2B T6 75 *Fuses (suffix S658) are not available for indicated light sources and ambient temperatures. Note: Luminaires requiring 105 C supply wire are furnished with 3 ft. of rated wire for external wiring connection. US: CAN: Copyright 2011 Cooper Crouse-Hinds 1091

8 Champ F2MV Mini-Floodlights Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, Group IIC Marine locations NEMA Type 4X Wet locations F2MV is a compact floodlight consisting of a Corro-Free epoxy coated copper-free aluminum enclosure, with stainless steel external hardware and impact-resistant glass. It is available for use with the following energy-saving mogul base HID lamp types and wattages: High Pressure Sodium (HPS) 50, 70, 100, and 150W Metal Halide (MH) 70, 100, and 175W Applications: Available in a variety of voltage ratings, this compact floodlight is suitable for marine and wet locations. Features and Benefits: Small, compact size easy to install and maintain 40 C, 55 C, and 65 C ambient suitability addresses high ambients common in industrial facilities Low ambient capability to 40 C perfect for colder climates Heavy-duty, copper-free aluminum enclosure with epoxy coating and stainless steel hardware provides a robust design with industrial grade construction and corrosion resistance Continuous silicone gasketing ensures wet and marine locations integrity Stainless steel tether chain and captive cover screws secure cover to housing ensures ease of maintenance Trunnion (yoke) mount design standard construction provides the greatest mounting flexibility, can be mounted vertically (wall), horizontally (rooftop or floor), or any angle in between Requires only two bolts to mount simplifies installation Heat- and impact-resistant tempered glass lens provides exceptional stability Shock-absorbing mogul base lamp socket cushions lamp, improves lamp life in harsh environments 3-axis resonance withstand and UL844 vibration compliant stands up to the tough jobs Precision formed aluminum reflector superior beam control, distribution and efficiency NEMA 7x6 floodlight pattern with lamp orientation base down the ideal light distribution for industrial applications Multi-tap ballasts offering a choice of 120, 208, 240, and 277V; 220V, 50Hz; 240V 50Hz; Tri-Tap (120, 277, and 347) and 480V ballasts are also available High light output with a low cost of operation a cost-effective, high wattage floodlight For use with SFA6 slipfitter adapter and SWB6 wall mount bracket accessories further enhances mounting flexibility Restricted breathing compliance cooler T-numbers for increased hazardous locations suitability Standard Materials: Enclosure (housing and lens cover) copper-free aluminum Cover chain and external hardware stainless steel Lens heat- and impact-resistant glass Gaskets silicone rubber Yoke copper-free aluminum Reflector diffused aluminum lighting sheet Standard Finishes: Enclosure and yoke Corro-Free epoxy powder coat Stainless steel natural Certifications & Compliances: NEC/CEC: Division 2, Groups A, B, C, D Marine locations NEMA Type 4X Wet locations IEC/NEC/CEC: Zone 2, Group IIC With suffix S826 and S826TB restricted breathing (Ex nr) option Zone 2 Division 2 UL Standards: 844 Hazardous (Divisions Classified) Locations 2279 Hazardous (Zones Classified) Locations 1572 Ordinary and Wet Locations, Marine Outside Type CSA Standards: C22.2 No. 137 CAN/CSA-E79 Series IEC Standards: Ratings (Electrical/Size): Sources/Wattages (Mogul Base Lamps) HPS 50, 70, 100, and 150W MH 70, 100, and 175W Voltages: Standard Voltage Ballasts Multi-tap (120, 208, 240, and 277V 60Hz) Dual-tap (120, 277V 60Hz) 50W HPS only 480V 60Hz Tri-tap (120, 277, 347V 60Hz) Optional Voltage Ballasts (Consult Cooper Crouse-Hinds) 220V or 240V 50Hz (for export) 220V 60Hz (for export) Isolated Ballasts (Consult Cooper Crouse-Hinds) 208, 240, or 480V (for Canada) Hub Size: Standard (2) 3 /4" NPT Optional (2) 25 mm (M25 x 1.5) or (2) 20 mm (M20 x 1.5) US: CAN: Copyright 2011 Cooper Crouse-Hinds 1105

9 Champ F2MV Mini-Floodlights Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, Group IIC Marine locations NEMA Type 4X Wet locations Ordering Information: Lamp Type High Pressure Sodium Metal Halide Base Catalog Number* Watts 3 /4" NPT Hub 25mm Hub 50 F2MVSY050 F2MVS25Y F2MVSY070 F2MVS25Y F2MVSY100 F2MVS25Y F2MVSY150 F2MVS25Y F2MVMY070 F2MVM25Y F2MVMY100 F2MVM25Y F2MVMY175 F2MVM25Y175 * To complete catalog number, add voltage and options suffix(es). For 20mm metric threads, change 25 to 20 in catalog number. Example: F2MVS20Y050/MT. Voltage Suffixes: Voltage (60Hz) Dual-Tap Tri-Tap Multi-Tap 480 Suffix /DT /TT /MT /480 Options Example:F2MVSY070/MT V2PC20 Series Yoke Voltage Lamp Type Watt Photocell Options: Description Suffix Instant Restrike and Ballast Guard Instant Restrike enables a hot HPS lamp to immediately restrike after a momentary loss of arc due to voltage fluctuation or power outage Ballast guard starter cut out switch prevents starter pulsing when lamp is cycling or inoperative; prolongs ballast and ignitor life 150W LX HPS only... TIR Factory assembled with HID lamp installed... FA Fused (not suitable for marine applications)... S658 Furnished with lamps (not installed)... S714 Pulse-start metal halide only... S828 Photocell 120V, 50/60Hz installed... V2PC20 Photocell V, 50/60Hz installed... V2PC22 Photocell 277V, 50/60Hz installed... V2PC27 Photometrics are available online US: CAN: Copyright 2011 Cooper Crouse-Hinds

10 Champ F2MV Mini-Floodlights Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, Group IIC Marine locations NEMA Type 4X Wet locations Photometric Data: Isofootcandle Chart F2MV 150W High Pressure Sodium (HPS) Catalog Number: F2MVSY150 Lamp: 150W Clear HPS Lumen Rating: 16,000 For 100W HPS, multiply footcandles by.55. For 70W HPS, multiply footcandles by.40. For 50W HPS, multiply footcandles by.24. Isofootcandle Chart F2MV 175W Metal Halide (MH) Catalog Number: F2MVMY175 Lamp: 175W Clear MH Lumen Rating: 14,000 For 100W MH, multiply footcandles by.58. For 70W MH, multiply footcandles by.37. Accessories (Order Separately): Slipfitter adapter To be mounted to yoke mount fixture Fits onto 2" pipe/conduit... Wall bracket Use with slipfitter adapter SFA6 for easy wall mounting and increased adjustability... SFA6 SWB6 Effective Projected Area (EPA): For windloading For proper pole selection Aiming Angle EPA FT FT FT 2 Footcandle Table: Mounting Footcandle Values for Isofootcandle Lines Height A B C D E 10' ' ' ' ' Photometrics are available online. US: CAN: Copyright 2011 Cooper Crouse-Hinds 1107

11 Champ F2MV Mini-Floodlights Cl. I, Div. 2, Groups A,B,C,D Cl. I, Zone 2, Group IIC Marine locations NEMA Type 4X Wet locations Temperature Performance Data: Catalog Series F2MVS F2MVM Type Lamp High Pressure Sodium Metal Halide Watts Zone 2 Lamp Selection (Mogul Base): Fixture Watts Type Bulb G.E. Osram Philips Venture F2MVSY HPS ED23 1 /2 or ET23 1 /2 LU50 LU50 C50S68 F2MVSY HPS ED23 1 /2 or ET23 1 /2 LU70 LU70 C70S62 F2MVSY HPS ED23 1 /2 or ET23 1 /2 LU100 LU100 C100S54 F2MVSY HPS ED23 1 /2 or ET23 1 /2 LU150/55 LU150/55 C150S55 F2MVMY MH ED28 MH70W/U/ED28 F2MVMY MH ED28 MH100/U/ED28 F2MVMY MH ED28 or BT28 MVR175/C/U M175/C/U MH175/C/U MH175/C/U Weights and Dimensions: Fixture Weight: 26 lbs. 40 C Ambient 55 C Ambient 65 C Ambient Temperature Code Temperature Code Temperature Code Div. 2 Supply Wire C Zone 2* Div. 2 Supply Wire C Zone 2* Div. 2 Fixture Aiming Supply Wire C Range Figure 50 T6 T3C 75 T6 T3C 75 T3B T T6 T3A 60 T5 T3A 75 T3 T T4 T2D 75 T4 T2C ** T4 T2A 75 T4 T2A 85 T3 T2A T6 T3C 75 T5 T3A 75 T4 T3A T4 T2D 75 T4 T2D 75 T4 T2C ** T3 T2A 75 T3 T2A 85 T3 T2A *Restricted breathing explosion protection, requires suffix S826 (TB). **Suitable for use in 65 C ambient without optional fuses. Photometrics are available online US: CAN: Copyright 2011 Cooper Crouse-Hinds

12 Champ FMV nr Floodlights Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, AEx nr II Cl. II, Div. 1, Groups F, G (up to 250W) Marine locations NEMA Type 4X and IP66 Wet locations The Champ FMV nr Series Floodlight offers exceptional illumination in industrial areas, both indoors and out. And, it comes standard as a restricted breathing luminaire. The Champ FMV nr Series Floodlight is easily adjusted to aim light where it s needed and is available in a wide variety of energy-saving mogul base HID light sources and wattages including: W High Pressure Sodium W Metal Halide Applications: The FMV is made with heavy-duty, diecast aluminum components and stainless steel hardware. It offers superior corrosion resistance to ensure longer life, which makes the FMV floodlight the ideal choice for a wide variety of industrial applications, including wet and marine environments. Features and Benefits: AEx nr, Ex nr restricted breathing rating is standard a hazardous location luminaire without additional accessories or options; restricted breathing offers cooler T-numbers for increased hazardous locations suitability NEMA 7x6 butterfly beam floodlight pattern wide, uniform and far reaching to provide excellent efficiency and more light where you need it NEMA Type 4X and IP66 construction is designed for use indoors and outdoors in marine and wet locations with stainless steel external hardware suitable for saltwater and corrosive applications Easy wiring standard terminal block with marked terminals saves time and eliminates wiring errors Vapor-tight sealing cable connector standard Will accommodate existing mounting hardware SFA6 slipfitter for pole and SWB6 wall mount Optional metric machining will accept M20 or M25 (must be specified on order) 40 C, 55 C and 65 C ambient suitability addresses high ambients common at industrial facilities Low ambient capability to -40 C perfect for colder climates Heavy-duty, die-cast copper-free aluminum enclosure with epoxy coating and stainless steel hardware provides a robust design with industrial grade construction and corrosion resistance Hinged door frame assembly has captive cover screws for ease of relamping Yoke mount design standard construction provides the greatest mounting flexibility, can be mounted vertically (wall), horizontally (rooftop or floor), or any angle in between 3-axis resonance withstand and UL844 vibration compliant can stand up to the tough jobs Precision formed aluminum reflector superior beam control, distribution and efficiency Multi-tap ballasts offering a choice of 120, 208, 240 and 277V; 220V 50Hz, 240V 50Hz, Tri-Tap (120, 277 and 347), and 480V ballasts are also available High light output with a low cost of operation cost-effectiveness in a high wattage floodlight For use with SFA6 Slipfitter Adapter and SWB6 Wall Mount Bracket accessories further enhances mounting flexibility Certifications & Compliances: NEC/CEC (NEC Ballast Gear and Socket): Division 2, Groups A, B, C, D Zone 2, AEx nr II Class II, Division 1, Groups F, G (up to 250W) Marine locations NEMA Type 4X and IP66 Wet locations IEC (IEC Ballast Gear and Socket): IEC Zone 2, Ex nr II (pending) UL/cUL Standards: 844 Hazardous (Divisions Classified) Locations Luminaires 1598A Supplemental Requirements for Luminaires for Installation on Marine Vessels IEC Standards: Standard Materials: Fixture housing and door frame assembly die-cast aluminum External hardware stainless steel Lens heat- and impact-resistant tempered glass Yoke aluminum Standard Finishes: Enclosure and yoke Corro-Free epoxy powder coat Stainless steel natural The only full frame trunnion mount floodlight with a T3 rating and a removable ballast tray assembly. Industry Best for Ease of Installation: 1. Removable ballast tray 2. Prewired to terminal blocks 3. Substantial room for wiring Ratings (Electrical/Size): Sources/Wattages (Mogul Base Lamps) HPS 150, 250, and 400W MH 175, 250, and 400W Voltages Standard Voltage Ballasts Multi-tap (120, 208, 240, and 277V 60Hz) Dual-tap (120 and 277V) 480V 60Hz Tri-tap (120, 277, 347V 60Hz) Optional Voltage Ballasts 220V or 240V 50Hz (for export) 220V 60Hz (for export) Isolated Ballasts 208, 240, or 480V (for Canada) Hub Size Standard 3/4" NPT Optional 25 mm (M25 x 1.5) or 20 mm (M20 x 1.5) US: CAN: Copyright 2011 Cooper Crouse-Hinds

13 Champ FMV nr Floodlights Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, AEx nr II Marine locations NEMA Type 4X and IP66 Wet locations Ordering Information for Floodlight with NEC Ballast: Lamp Type Watts Yoke Mount 3 /4" NPT Hub 150 FMVSY150/MT 76 High Pressure Sodium 250 FMVSY250/MT FMVSY400/MT FMVMY175/MT 76 Metal Halide 250 FMVMY250/MT FMVMY400/MT 76 Voltage Suffixes Voltage (60Hz) Dual-Tap Tri-Tap Multi-Tap 480 Suffix /DT /TT /MT /480 To complete catalog number, add voltage and options suffix(es). Example: FMVMY400/MT 76 M25 V2PC20 Series Lamp Type Yoke Watt Voltage Beam Spread Metric Entry Options Photocell 150W HPS fixtures are furnished with ANSI spec/s55 ballasts for 55V lamps. For 100V lamps, add suffix "CE" after voltage suffix. Example: FMVSY150/MT CE 76. Photometric Data: Isofootcandle Chart FMV 400W High Pressure Sodium (HPS) Catalog Number: FMVSY Lamp: 400W Clear HPS Lumen Rating: 50,000 For 150W HPS, multiply footcandles by.32. For 250W HPS, multiply footcandles by 0.6. Fixture located at 0, 0 aiming angle at 45 (Note: See Figures 1 and 2). Isofootcandle Chart FMV 400W Metal Halide (MH) Catalog Number: FMVMY Lamp: 400W Clear MH Lumen Rating: 34,000 For 250W MH, multiply footcandles by 0.6. Fixture located a 0, 0 aiming angle 45 (Note: See Figures 1 and 2). Options: Description Suffix Instant Restrike and Ballast Guard Instant restrike enables a hot HPS lamp to immediately restrike after a momentary loss of arc due to voltage fluctuation or power outage Ballast guard starter cut out switch prevents starter pulsing when lamp is cycling or inoperative; prolongs ballast and ignitor life. 150W LX HPS only... TIR Factory assembled with HID lamp installed... FA Fused (not suitable for marine applications)... S658 20mm metric thread for conduit opening... M20 25mm metric thread for conduit opening... M25 3 /4" NPT hub conduit opening... NPT75 Furnished with lamps (not installed)... S714 Retention chain... S831 Pulse-Start Metal Halide... S828 Enclosure machined for 2 conduit/cable entries... S886 Options for Photocell*: Description Photocell 120V, 50/60Hz installed... Photocell V, 50/60Hz installed... Photocell 277V, 50/60Hz installed... *Photocell for Div. 2 installation only. Suffix V2PC20 V2PC22 V2PC27 Effective Projected Area (EPA): For windloading For proper pole selection Aiming Angle EPA FT FT FT 2 Footcandle Table: Mounting Height Footcandle Values for Isofotcandle Lines A B C D E 15' ' ' ' ' ' Accessories (Order Separately): Slipfitter Adapter To be mounted to yoke mount fixture Fits onto 2" pipe/conduit... Wall Bracket Use with slipfitter adapter SFA6 for easy wall mounting and increased adjustability... SFA6 SWB6 US: CAN: Copyright 2011 Cooper Crouse-Hinds 1095

14 Champ FMV nr Floodlights Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, AEx nr II Marine locations NEMA Type 4X and IP66 Wet locations Weights and Dimensions: Net Fixture Weights (Lbs.): Fixtures FMVS FMVM 150W W W SFA6 (Slipfitter Adapter) Add 4 lbs., SWB6 (Wall Bracket) Add 6 lbs. FIGURE 1 FIGURE 2 FIGURE US: CAN: Copyright 2012 Cooper Crouse-Hinds

15 Champ FMV nr Floodlights Cl. I, Div. 2, Groups A,B,C,D Cl. I, Zone 2, AEx nr II Marine locations NEMA Type 4X and IP66 Wet locations Temperature Performance Data: Catalog Series FMVS FMVM Type Lamp High Pressure Sodium Metal Halide Pulse- Start Metal Halide Watts ** * 400** * Zone 2 *Suitable for use in 65 C ambient without optional fuses. **Suitable for use in 55 C ambient without optional fuses. 40 C Ambient 55 C Ambient 65 C Ambient Fixture Aiming Temparature Code Temperature Code Temperature Code Range Figure Div. 2 Supply Wire C Zone 2 Div. 2 Supply Wire C Zone 2 Div. 2 Supply Wire C T T T T T T T T T T T T T T T T T T T3 T1 90 T3 T T3 T1 105 T3 T T3 T1 105 T3 T T T T T T T T T T3 T T T T T T T T T T3 T T T T T T3 T1 105 T2 T T T T T T T T T3 T1 105 T3 T T T T T T T T T3 T1 105 T3 T ** T T ** T T3 T ** T3 T1 105 T3 T Lamp Selection (Mogul Base): Fixture Watts Type Bulb G.E. Osram Philips FMVSY HPS ED23 1 /2 BT25 LU150/55 LU150/55 C150S55 FMVSY HPS ED18 1 /2 or ET18 LU250 LU250 C250S50 FMVSY HPS ED37 1 /2 BT37 LU400 LU400 C400S51 FMVMY MH ED28 or BT28 MVR175/U M175/U MH175/U FMVMY MH ED28 or BT28 MVR250/U M250/U MH250/U FMVMY MH ED37 or BT37 MVR400/U M400/U MH400/U Photometrics are available online. US: CAN: Copyright 2011 Cooper Crouse-Hinds 1097

16 Champ FMV1000 nr High Wattage Floodlights Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, AEx nr II, Group IIC Marine locations NEMA Type 4X and IP56 Wet locations The Champ FMV1000 Series High Wattage Floodlight is the best in its class with heavy-duty vapor-tight housing designed exclusively for harsh industrial areas requiring broad area lighting. The FMV1000 Series Floodlight boasts restricted breathing and easy-to-wire terminal blocks as standard. It is available in the following HID lamp sources and wattages: 600, 750, 1000W High Pressure Sodium 1000, 1500W Metal Halide Applications: The Champ FMV1000 Series is NEMA Type 4X and IP56 watertight, and its heavy-duty welded extruded aluminum housing and stainless steel hardware provide a robust design suitable for the most corrosive/marine environments. Restricted breathing comes standard with this NEMA Type 4X and IP56 rated floodlight. Features and Benefits: AEx nr, Ex nr restricted breathing rating is standard a hazardous location luminaire without additional accessories or options; restricted breathing offers cooler T-numbers for increased hazardous locations suitability NEMA 7x6 butterfly beam floodlight pattern wide, uniform and far reaching to provide excellent efficiency and more light where you need it NEMA Type 4X and IP56 construction is designed for use indoors and outdoors in marine and wet locations with stainless steel external hardware suitable for saltwater and corrosive applications Easy wiring standard terminal block with marked terminals saves time and eliminates wiring errors Vapor-tight sealing cable connector standard Standard machining will accept 3 /4 inch NCGB or 3 /4 inch Myers hub (Myers hub is an option). Optional metric machining will accept M20 or M25 (must be specified on order) Low and high ambient capability to -40 C perfect for colder climates, 50 C workhorse in hot climates Heavy-duty, extruded copper-free aluminum enclosure with epoxy coating and stainless steel hardware provides a robust design with industrial grade construction and corrosion resistance Precision formed aluminum reflector superior beam control, distribution and efficiency High light output with a low cost of operation cost-effectiveness in a high wattage floodlight Certifications & Compliances: NEC/CEC (NEC Ballast Gear and Socket): Division 2, Groups A, B, C, D Zone 2, AEx nr II, Group IIC Marine locations IP56 Wet locations NEMA Type 4X IEC (IEC Ballast Gear and Socket) pending: IEC Ex Zone 2 Ex na nr IIC Standard Materials: Housing extruded aluminum External hardware stainless steel Yoke 316 stainless steel Lens heat- and impact-resistant tempered glass Gasketing neoprene Industry Best for Ease of Installation: 1. Removable ballast tray 2. Prewired to terminal blocks 3. Substantial room for wiring Standard Finishes: Aluminum Corro-Free epoxy powder coat Stainless steel natural Ratings (Electrical/Size): Sources/Wattages (Mogul Base Lamps) HPS 600, 750, and 1000W MH 1000W MH 1500W non-hazardous location rated Voltages: Standard Voltage Ballasts Multi-tap (120, 208, 240, and 277V 60Hz) 480V 60Hz Tri-tap (120, 277, 347V 60Hz) Optional Voltage Ballasts 220V or 240V 50Hz (for export) 220V 60Hz (for export) Isolated Ballasts 208, 240, or 480V (for Canada) Hub Size: 3 /4" NPT standard M20 or M25 optional Dual entry NPT or metric US: CAN: Copyright 2011 Cooper Crouse-Hinds

17 Champ FMV1000 nr High Wattage Floodlights Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, AEx nr II, Group IIC Marine locations NEMA Type 4X and IP56 Wet locations Ordering Information for Floodlight with NEC Ballast: Lamp Type Watts Base Catalog Number* High Pressure Sodium Metal Halide *To complete catalog number, add voltage and options suffix(es). 600 FMVSY FMVSY FMVSY FMVMY FMVMY Voltage Suffixes: Voltage (60Hz) Dual-Tap Tri-Tap Multi-Tap 480 Suffix /DT /TT /MT /480 Options Example: FMVS Y1000/MT 76 M25 S828 Series Lamp Type Yoke Watt Voltage Beam Spread Temperature Performance Data: Figure Accessories (Order Separately): Metric Entry Pulse-start Metal Halide Only Slipfitter adapter: To be mounted to yoke mount fixture; fits onto 2" pipe/conduit... SFA6 Wall bracket: Use with slipfitter adapter SFA6 for easy wall mounting and increased adjustability... SWB6 Photocell in DS cover for use with FS/FD box: 120V, 50/60Hz... D2S , 50/60Hz... D2S Options: Catalog Series FMVS FMVM Description Suffix 20mm metric thread for conduit opening... M20 25mm metric thread for conduit opening... M25 3 /4" NPT hub conduit opening... NPT75 Pulse-start metal halide only... S828 Retention chain... S831 Enclosure machined for 2 conduit/cable entries... S886 Factory assembled, lamp installed in lampholder... FA Weights and Dimensions: Net Fixture Weights (Lbs.): Lamp Type High Pressure Sodium Metal Halide Pulse- Start Metal Halide Wattage Fixture Series FMVSY FMVSY FMVSY FMVMY FMVMY Zone 2 40 C Ambient 50 C Ambient Temperature Code Div. 2 Supply Wire C Zone 2 Temperature Code Div. 2 Supply Wire C Range Fixture Aiming 600 T3 T1 90 TS T T3 T1 90 T3 T T3 T1 90 T3 T Figure 1000 T3 T1 90 T3 T T3 T1 90 T3 T T3 T T3 T1 90 T3 T T3 T Ø.5 MTG HOLES US: CAN: Copyright 2011 Cooper Crouse-Hinds 1099

18 Champ FMV1000 nr High Wattage Floodlights Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, AEx nr II, Group IIC Marine locations NEMA Type 4X and IP56 Wet locations Effective Projected Area (EPA): For windloading For proper pole selection Aiming Angle EPA FT FT FT 2 Photometric Data: ISO Footcandle Chart FMV ISO Footcandle Chart FMV 1000W High Pressure Sodium (HPS) 1000W Metal Halide (MH) Catalog Number: FMVSY Catalog Number: FMVMY Lamp: 1000W Clear HPS Lamp: 1000W Clear MH Lumen Rating: 140,000 Lumen Rating: 110,000 Fixture located at 0, 0 aiming angle at 45 For 1500W MH, multiply footcandles by 1.4 (Note: See Figures 1 and 2). Fixture located a 0, 0 aiming angle at 45 (Note: See Figures 1 and 2). Lamp Selection (Mogul Base): Fixture Watts Type Bulb G.E. Osram Philips FMVSY HPS T15 LU600/T C600S106 FMVSY HPS ED37 LU750 FMVSY HPS E25 LU1000 C1000S52/ED37 FMVMY MH ED37 MVR750/VBU/PA FMVMY MH BT56 MVR1000/U MH1000/U FMVMY MH BT56 MVR1500/U/SPORTS MH1500/U US: CAN: Copyright 2012 Cooper Crouse-Hinds

19 Champ Voyager nr Stainless Steel Floodlight Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, AEx nr II, Group IIC IEC Zone 2, Ex nr II ATEX Marine locations Wet locations The Cooper Crouse-Hinds Champ Voyager nr Stainless Steel Floodlight offers the industry s coolest temperature ratings so it can operate below the ignition temperature of vapors and gases in your classified area. The Champ Voyager nr Floodlight boasts a wide, powerful beam to deliver more light to your process or pathway. Standard terminal blocks and a removable ballast component tray bring you the best combination of easy wiring and simple maintenance in one rugged package. Applications: This unique combination of features makes the Champ Voyager nr Floodlight ideal for outdoor, marine, corrosive, and high temperature locations. And because the Champ Voyager nr Floodlight meets international standards, you can install it anywhere in the world. Features and Benefits: AEx nr, Ex nr restricted breathing rating is standard a hazardous location luminaire with excellent T3 and T4 ratings without additional accessories or options NEMA 7x6 "butterfly beam" floodlight pattern wide, uniform and far reaching to reduce the number of luminaires you need, providing excellent luminaire efficiency more light where you need it Easy wiring standard terminal block with marked terminals saves time and eliminates wiring errors Removable ballast component tray for capacitor, igniter and terminal block to simplify maintenance and save money Housing, hinges, door frame and mounting yoke are all 316 stainless steel for marine and wet locations robust construction suitable for saltwater and corrosive applications Now available with IEC gear and certified to the IEC Ex ATEX Directive. The only mogul base Division 2 and Zone 2 stainless steel floodlight with restricted breathing (vapor-tight design) as standard construction. Certifications & Compliances: NEC/CEC (NEC Ballast Gear and Socket): Division 2, Groups A, B, C, D Zone 2, AEx nr II, Group IIC NEMA Type 4X and IP66 IEC (IEC Ballast Gear and Socket): IEC Zone 2, Ex nr II ATEX UL/cUL Standards: 844 Hazardous (Divisions Classified) Locations 1598 Luminaires Marine Locations 1598A Supplemental Requirements for Luminaires for Installation on Marine Vessels Standard Materials: Enclosure (housing and lens frame) 316 stainless steel Lens heat- and impact-resistant tempered glass Gaskets silicone rubber Yoke and yoke bracket 316 stainless steel Reflector formed specular (dimpled glossy surface) aluminum Cable gland cord grip and locknut polyamide 6, neoprene bushing Standard Finishes: 316 stainless steel natural Photometrics are available online. Industry Best for Ease of Installation: 1. Removable ballast tray 2. Prewired to terminal blocks 3. Substantial room for wiring Ratings (Electrical/Size): Sources/Wattages (Mogul Base Lamps) High Pressure Sodium (HPS) 150, 250, and 400W Metal Halide (MH) 175, 250, and 400W Voltages: Standard Voltage Ballasts Multi-tap (120, 208, 240, and 277V 60Hz) 480V, 60Hz Tri-tap (120, 277, 347V 60Hz) Optional Voltage Ballasts (for export) 220V or 240V, 50Hz 220V, 60Hz Isolated Ballasts 208, 240, or 480V (for Canada) Hub Size: Standard: 3 /4" NPT with a 3 /4" gland sealing connector US: CAN: Copyright 2011 Cooper Crouse-Hinds 1101

20 Champ Voyager nr Stainless Steel Floodlight Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, AEx nr II, Group IIC IEC Zone 2, Ex nr II ATEX Marine locations Wet locations Ordering Information for Floodlight with IEC Ballast: Lamp Type IEC Ref. Watts Catalog Number* 150 NSSFMVSY150/220 HPS HSE/HST 250 NSSFMVSY250/ NSSFMVSY400/ NSSFMVMY150/220 MH HIE 250 NSSFMVMY250/ NSSFMVMY400/220 *Uses IEC lamp socket E40. NSSFMV Floodlights are designed with IEC ballast gear and lamp socket, providing certification to the IEC Ex ATEX Directive. Ordering Information for Floodlight with NEC Ballast: Lamp Type Watts Catalog Number* High Pressure Sodium Metal Halide 150 SSFMVSY SSFMVSY SSFMVSY SSFMVMY SSFMVMY SSFMVMY Voltage Suffixes: Voltage Suffix Voltage Suffix Tri-Tap (120, 277, /TT Hz / V, 60Hz) Multi-Tap 120, 208, 240, /MT Hz / V, 60Hz) 480V, 60Hz / Hz / V, 60Hz /MV Hz / *To complete catalog number, add voltage and options suffix(es) Example: SSFMVSY150/MT 76. Temperature Performance Data: Catalog Series SSFMVS SSFMVM Type High Pressure Sodium Lamp Metal Halide Watts **Suitable for use in 55 C ambient without optional fuses. For U.S. market, use MH Pulse Start option. Zone 2 40 C Ambient 55 C Ambient Temperature Code Div. 2 Supply Wire C Zone 2 Temperature Code Div. 2 Fixture Aiming Supply Wire C Range Figure 150** T4 T2B 90 T4 T2B ** T T T3 T ** T3 T2 90 T3 T ** T T T Accessories (Order Separately): Stainless steel slipfitter adapter... SFA6 SS Stainless steel wall mount bracket... SWB6 SS Standard slipfitter adapter (cast aluminum)... SFA6 Standard wall mount bracket (cast aluminum)... SWB6 Photocell in DS cover for use with FS/FD box: 120V, 50/60Hz... D2S V, 50/60Hz... D2S FIGURE 1 FIGURE 2 Photometrics are available online US: CAN: Copyright 2011 Cooper Crouse-Hinds

21 Champ Voyager nr Stainless Steel Floodlight Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, AEx nr II, Group IIC IEC Zone 2, Ex nr II ATEX Marine locations Wet locations Effective Projected Area (EPA): For windloading For proper pole selection Aiming Angle EPA FT FT FT 2 Weights and Dimensions: Net Fixture Weights (Lbs.) Luminaire HPS MH 150W W W W [1.77 ] (45mm) Options: Description Suffix Instant Restrike and Ballast Guard Instant Restrike enables a hot HPS lamp to immediately restrike after a momentary loss of arc due to voltage fluctuation or power outage Ballast guard starter cut out switch prevents starter pulsing when lamp is cycling or inoperative; prolongs ballast and ignitor life... TIR 150W LX HPS only Factory assembled with HID lamp installed... FA Fused (not suitable for marine applications)... S658 20mm metric thread for conduit opening... M20 25mm metric thread for conduit opening... M25 3 /4" NPT hub conduit opening... NPT75 Furnished with lamps (not installed)... S714 Pulse-start metal halide only... S828 Enclosure machined for 2 conduit/cable entries... S886 Yoke mount and slipfitter... SFA6 Photometrics are available online. US: CAN: Copyright 2011 Cooper Crouse-Hinds 1103

22 Champ Voyager nr Stainless Steel Floodlight Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, AEx nr II, Group IIC IEC Zone 2, Ex nr II ATEX Marine locations Wet locations Photometric Data: MH Wide Beam Reflector HPS Wide Beam Reflector ISOFOOTCANDLE CHART ISOFOOTCANDLE CHART 400W Metal Halide (MH) 400W High Pressure Sodium (HPS) Catalog Number: SSFMVMY400/MT Catalog Number: SSFMVSY400/MT Lamp: 400W Clear MH Lamp: 400W Clear HPS Lumen Rating: 34,000 Lumen Rating: 50,000 Luminaire located at 0, 0 aiming angle at 45 down from horizontal Luminaire located at 0, 0 aiming angle at 45 down from horizontal For 175W MH, multiply footcandles by For 250W HPS, multiply footcandles by For 150W HPS, multiply footcandles by For 250W HPS, multiply footcandles by Mounting Footcandle Values for Isofootcandle Lines Height A B C D E F 10' ' ' ' ' ' ' Mounting Footcandle Values for Isofootcandle Lines Height A B C D E F 10' ' ' ' ' ' ' Photometrics are available online US: CAN: Copyright 2011 Cooper Crouse-Hinds

23 Hazard Gard H.I.D. Floodlights Factory-sealed Cl. I, Div. 1 & 2, Groups C, D Cl. I, Div. 1 & 2, Groups B, C, D (add suffix GB) Cl. I, Zone 1 Marine Locations, IP66 Wet Locations Applications: Hazard Gard Luminaires with Trunnion Arm (S812 suffix) and EV912 High Bay Reflector are used in: Heavy process industries where flammable or explosive vapors or gases are present Hazardous areas, both indoors and outdoors where long life and low maintenance costs are desired Petroleum refineries, chemical, petrochemical, and other heavy process industry facilities Hazardous locations requiring elevated ambient capability For mounting to a wall or structure Mounted on a pole, when used with the SFA6 slipfitter adapter Features: Luminaire is factory wired; power is fed through "wireless" connection block which serves as a mechanical seal between conduit and ballast compartments, eliminating the need for an external, field-installed seal; the result is fast, easy installation High bay reflectors of Alzak aluminum Internally fluted glass globes reduce glare and provide comfortable viewing light Wide range of light sources and wattages to meet specific lighting needs 50, 70, 100, 150, 200, 250 and 400W high pressure sodium (HPS); 70, 100, 175, 250 and 400W metal halide (MH) High power factor (90%+) ballasts reduce power costs allow more luminaires per circuit Elevated ambient capability permits reliable operation at high ambient temperature; selected luminaires are suitable for ambient temperatures up to 65 C Integral ballasts separate ballasts are not required; lowest installed cost Factory-sealed, porcelain, mogul base socket The trunnion arm gives you the ability to offer a Hazard Gard floodlight with varying degrees of adjustability between -90 and +90 When mounting on a wall, there are numerous mounting arrangements due to the pre-drilled openings in the wall bracket Certifications and Compliances: NEC/CEC: Division 1 and 2, Groups B (with GB suffix), C, D UL Standard: 844, 595 CSA Standard: C22.2 No. 137 Standard Materials: Mounting module, cover, ballast housing, guard, globe ring copper-free aluminum Globe heat- and impact-resistant glass Exterior hardware stainless steel Lamp socket porcelain with stainless steel screw shell Reflector high bay: Alzak aluminum Standard Finishes: Copper-free aluminum epoxy powder coat Alzak natural (anodized) Options: Size Ranges: 3 /4" *CSA certified luminaires are not available with multi-tap ballast or S658 fuse option. Alzak is a registered trademark of ALCOA. Description Suffix Fused... S658 Not suitable for marine applications Ballast-Gard... BG HPS only Instant Restrike... IR Cannot be used with BG or QTZ options W LX HPS only Quartz Auxiliary Lighting... QTZ Not available with 400W MH Uses 100 watt single-ended lamp Lamp not included Group B Suitability... GB Electrical Rating Ranges: 120, 208, 240, 277, 347, 480, 600, multi-tap* 50 to 400 watts Ordering Information Catalog number includes guard, trunnion arm, and high bay reflector Luminaire Cat. # Watts Hub Size (In.) High Pressure Sodium EVMA42051/volts S812 EV /4 EVMA42071/volts S812 EV /4 EVMA42101/volts S812 EV /4 EVMA42151/volts S812 EV /4 EVMA42201/volts S812 EV /4 EVMA42251/volts S812 EV /4 EVMA42401/volts S812 EV /4 Metal Halide EVMA92071/volts S812 EV /4 EVMA92101/volts S812 EV /4 EVMA92171/volts S812 EV /4 EVMA92251/volts S812 EV /4 EVMA92401/volts S812 EV /4 Note: Replace "volts" with Suffix from Voltage Suffix Table below Temperature Performance Data: Hazard Gard Luminaire with Trunnion Arm (S812 suffix) Maximum Ambient Class I Watts 40 C 55 C 65 C High Pressure Sodium 50 T4 T4 T3C 70 T4 T4 T3C 100 T4 T4 T3C 150 T4 T4 T3C 200 T3A 250 T3A 400 T3A Metal Halide 70 T3 T3 100 T3 T3 175 T3 T3 250 T3 T3 400 T2D Note: See Section 4L for additional luminaire information. Required Accessories: EABC Cat. # Hub Size (In.) EABC26 3 /4 UNL 90 Angle Cat. # Size UNL205 3 /4 to 3 /4 ECGJH Flexible Cat. # Length Size ECGJH / US: CAN: Copyright 2011 Cooper Crouse-Hinds

24 FZD Series Floodlight Luminaire Cl. I, Div. 1 & 2, Groups C, D Cl. I, Zone I Marine Locations Wet Locations, IP66 Finally, a true floodlight luminaire for hazardous areas. Cooper Crouse-Hinds FZD Series Luminaires are the first to deliver NEMA 7 x 6 floodlight distribution patterns for Division 1 and Zone 1 environments. That means you ll need fewer of them to illuminate a given area. With their labor-saving features and flexible mounting options, the FZD Series is ideal for: Heavy process industries where flammable or explosive vapors or gases are present Hazardous areas, both indoors and outdoors, including those requiring elevated ambient capability, where long life and low maintenance costs are desired Petroleum refineries, chemical, petrochemical, and other heavy process industrial facilities Mounting to a wall, structure, or pole (with pole mount adapter accessory) Features and Benefits: NEMA 7 6 floodlight distribution pattern is standard ideal light distribution for industrial applications; requires fewer luminaires in general lighting applications than required when using general area luminaires with high bay reflectors Internal reflector available in wide and narrow beam options; enclosed in glass tube, reducing maintenance and enhancing light output Heavy duty, cast copper-free aluminum construction with epoxy powder coat finish and stainless steel hardware provides long life in industrial, abusive environments Explosionproof threaded construction suitable for hazardous and industrial applications; easy to maintain with no bolted covers O-ring gaskets on all threaded openings allow NEMA Type 4X and marine listing for the harshest outdoor environments 40 C, 55 C, and 65 C ambient suitability ideal for use in high ambient temperature areas common in industrial facilities Factory-sealed ballast housing keeps ballast isolated from wiring chamber Trunnion (yoke) mount design standard construction provides the greatest mounting flexibility; can be vertically (wall) or horizontally (rooftop or floor) mounted Simple installation requires only two bolts to mount Mounting flexibility pole mount with SFA6-XP pole mount adapter (shown below) or wall or ceiling mount with FZD-KIT1 mounting accessory kit (shown above). Certifications and Compliances: NEC/CEC Division 1, Group B (with suffix - GB*), C, D Zone 1, Group IIB+H2 (with suffix -GB*), IIB AEx d IIB+H (with suffix -GB*), IIB Ex d IIB+H2 (with suffix -GB*), IIB Marine Locations Wet Locations Enclosure Type 4X IP66 UL Listed (UL Standards 844, 1598, 1598A, 2279) cul Listed (certified by UL to CSA Standard C22.2 No. 137 and CAN/CSA- E ) *See options for Group B and IIB+H2 ordering information. Standard Materials: Luminaire housing, covers, socket holder, lamp tube end rings copperfree aluminum External hardware stainless steel Glass lamp tube heat- and impactresistant tempered glass O-ring gaskets neoprene/silicone Yoke aluminum Trunnion adapter brass Standard Finishes: Aluminum Corro-free epoxy powder coat Stainless steel natural Brass natural Luminaire Weights (lbs.): Luminaire FZDS (HPS) FZDM (MH) 150 watt to 250 watt watt Ratings: FZD with separate ballast enclosure Pole Mount Adapter Sources/Wattages (Mogul Base Lamps) HPS 150, 250 & 400 watts MH 175, 250 & 400 watts Voltages Standard Voltage Ballasts Multi-tap (120, 208, 240 & 277 V, 60 Hz) 120 V, 60 Hz 480 V, 60 Hz Tri-tap (120, 277 & 347 V, 60 Hz) Optional Voltage Ballasts 220 V, 60 Hz 220 V, 50 Hz Hub Size Standard: Two 3 /4" NPT entries Optional: Two 25 mm (M25) entries (consult Cooper Crouse-Hinds) Dimensions (In Inches): US: CAN: Copyright 2011 Cooper Crouse-Hinds 1109

25 FZD Series Floodlight Luminaire Cl. I, Div. 1 & 2, Groups C, D Cl. I, Zone I Marine Locations Wet Locations, IP66 Ordering Information: Lamp Type Wide Beam Reflector 7 x 6 Distribution High Pressure Sodium Metal Halide Pulse Start Metal Halide Watts Cat. #* Yoke Mount With 3 /4" NPT Hubs 150 FZDS2NY150W/MT 250 FZDS2NY250W/MT 400 FZDS2NY400W/MT 175 FZDM2NY175W/MT 250 FZDM2NY250W/MT 400 FZDM2NY400W/MT 175 FZDM2NY175W/MT S FZDM2NY250W/MT S FZDM2NY400W/MT S828 Narrow Beam Reflector Spotlight Distribution 150 FZDS2NY150N/MT High Pressure Sodium 250 FZDS2NY250N/MT 400 FZDS2NY400N/MT 175 FZDM2NY175N/MT Metal Halide 250 FZDM2NY250N/MT 400 FZDM2NY400N/MT 175 FZDM2NY175N/MT S828 Pulse Start Metal Halide 250 FZDM2NY250N/MT S FZDM2NY400N/MT S828 To complete the catalog number, add option suffix(es) if desired. Example: FZDS2NY400W/MT-S658 *All FZD catalog numbers shown above are with multi-tap ballasts (120, 208, 240 & 277 V, 60 Hz). The "MT" in the catalog number may be changed to any of the voltage suffixes listed below. 150 watt HPS luminaires are furnished with ANSI spec/s55 ballasts for 55 V lamps. FZD With Separate Ballast Enclosure: Glass Fiber Reinforced Polyester Ballast Enclosure With Cable Entry Lamp Type Watts T-Code Cat. # Wide Beam Reflector NEMA 7 x 6 Distribution HPS/MH 250 T4 NOR Metal Halide 400 T3 NOR High Pressure Sodium 400 T3 NOR Narrow Beam Reflector Spotlight Distribution HPS/MH 250 T4 NOR Metal Halide 400 T3 NOR High Pressure Sodium 400 T3 NOR Stainless Steel Ballast Enclosure With Cable Entry Lamp Type Watts T-Code Cat. # Wide Beam Reflector 7 x 6 Distribution HPS/MH 250 T4 NOR Metal Halide 400 T3 NOR High Pressure Sodium 400 T3 NOR Narrow Beam Reflector Spotlight Distribution HPS/MH 250 T4 NOR Metal Halide 400 T3 NOR High Pressure Sodium 400 T3 NOR Voltage Suffixes: Standard Voltages Optional Voltages Suffix Suffix Multi-tap (120, 208, 240, 277 V, 60 Hz) /MT 220 V, 50 Hz / Tri-tap (120, 277, 347 V, 60 Hz) /TT 220 V, 60 Hz / V, 60 Hz / V, 60 Hz /480 Options: Description Suffix Ballast-Gard starter cut-out switch prevents starter pulsing when lamp is cycling or inoperative; prolongs ballast and igniter life (HPS only; not available with IR option)...bg Factory assembled with HID lamp installed for additional labor savings...fa Factory certified: Division 1, Group B and Zone 1, Group IIB + H2...GB Instant restrike enables a hot HPS lamp to immediately restrike after a momentary loss of arc due to voltage fluctuation or power outage; it has no affect on the warmup period of cold lamps; available for use with 150 watt HPS only...ir Fusing protects ballast and capacitor against abnormal line conditions (not suitable for marine applications)...s658* *When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. Accessories: (order separately) For Pole Mounting Cat. # Pole mount adapter SFA6-XP Division 1, Groups B, C, D Attach to yoke; fits 2" NPT conduit pole Flexible explosionproof coupling ECLK236 Elbow fitting EL296-SA For Wall Or Ceiling Mounting Kit includes: FZD-KIT1 EABC26-SA conduit outlet box, ECLK236 flexible explosionproof coupling, and EL296-SA elbow fitting Temperature Performance Data: Lamp 150 watt HPS 250 watt HPS 400 watt HPS 175 watt Metal Halide 250 watt Metal Halide 400 watt Metal Halide Ambient Temp. C Division 1, Zone 1 40 T3C T3C T3B T3C T3C T3B T3C T3C T3B T3A T T T3A T T T3A T T3 90 Supply Wire C US: CAN: Copyright 2011 Cooper Crouse-Hinds

26 FZD Series Floodlight Luminaire Photometric Data Photometrics: Note: There are no aiming angle limitations for the FZD. The only limitations are those encountered by interference of the trunnion arm. The trunnion arm may be mounted on vertical or horizontal surfaces to overcome any limitations. HPS Narrow Beam Reflector Isofootcandle Chart FZD 400W High Pressure Sodium (HPS) Catalog Number FZDS2NY400N Lamp: 400 W Clear HPS Lumen rating: 50,000 Luminaire located at 0,0 Aiming Angle at 45 down from horizontal For 150W HPS, multiply footcandles by For 250 W HPS, multiply footcandles by 0.6. Footcandle Values For Isofootcandle Lines Mtg. Ht. A B C D E F G 10' ' ' ' ' HPS Wide Beam Reflector Isofootcandle Chart FZD 400W High Pressure Sodium (HPS) Catalog Number FZDS2NY400W Lamp: 400W Clear HPS Lumen rating: 50,000 Luminaire located at 0,0 Aiming Angle at 45 down from horizontal For 150W HPS, multiply footcandles by For 250W HPS, multiply footcandles by 0.6. Footcandle Values For Isofootcandle Lines Mtg. Ht. A B C D E F 10' ' ' ' ' MH Narrow Beam Reflector Isofootcandle Chart FZD 400W Metal Halide (MH) Catalog Number FZDM2NY400N Lamp: 400W Clear MH Lumen rating: 34,000 Luminaire located at 0,0 Aiming Angle at 45 down from horizontal For 175W MH, multiply footcandles by For 250W MH, multiply footcandles by 0.6. MH Wide Beam Reflector Isofootcandle Chart FZD 400W Metal Halide (MH) Catalog Number FZDM2NY400W Lamp: 400W Clear MH Lumen rating: 34,000 Luminaire located at 0,0 Aiming Angle at 45 down from horizontal For 175W MH, multiply footcandles by For 250W MH, multiply footcandles by 0.6. Footcandle Values For Isofootcandle Lines Mtg. Ht. A B C D E F G 10' ' ' ' ' Effective Projected Area (EPA): For windloading For proper pole selection Aiming Angle EPA ft ft 2 Footcandle Values For Isofootcandle Lines Mtg. Ht. A B C D E F 10' ' ' ' ' US: CAN: Copyright 2011 Cooper Crouse-Hinds 1111

27 Engineering Safety & Productivity Champ FMV LED Series Floodlight Fixtures Leading the way in LED technology for harsh and hazardous area usage

28 Champ FMV LED Series Floodlight Fixtures High-performance, high-brightness Champ FMV LED floodlight fixture brilliantly combining safety, reliability and energy efficiency. The world s most demanding environments need smart new lighting ideas and innovative approaches to enhancing safety. You need lighting that cuts the overall cost of ownership. Lighting that improves energy efficiency and lives up to ever-escalating environmental standards. You need all of this innovation from a single source. It could only be: Cooper Crouse-Hinds. Introducing ESP solutions. For more than 100 years, Cooper Crouse-Hinds has exceeded customer expectations when it comes to new ideas and technological advancements. Today, as the electrical industry s global leader for hazardous environments, we continue to reach beyond the expected especially with our commitment to ESP (Engineering Safety & Productivity). Time to look at LEDs in a whole new light. Dramatic advances in LED technology have broadened the applicability of this type of illumination, creating an exciting new option for hazardous, industrial and other highly demanding locations. Compared to traditional light sources, LED can deliver longer life, enhanced energy efficiency, greater eco-friendliness, lowered maintenance demands and equal or better quality of light. Innovative applications for this exciting technology are a natural fit for us, and LED lighting solutions have rapidly become an integral part of our vision. Traditional HID Floodlight Champ FMV LED Floodlight You're faced with high maintenance and operating costs within your coal-fired power plant. In addition, frequent lamp failures pose a safety concern where continuous lighting is required. You re tasked with identifying a lighting solution that reduces ownership costs and lowers downtime while maintaining similar or improved light levels. Old Way: Conventional 400 Watt Probe Start Metal Halide Floodlights are installed throughout the facility and operate continuously. Regular maintenance is required to replace burned-out lamps, which could require scaffolding to be built or other lifting equipment to be rented and can put maintenance personnel into dangerous locations at great heights. According to the Bureau of Labor Statistics, 22% of job related injuries come from workers falling while on the job. Additionally, any energy that is wasted in operation is lost profit to a power plant. New Way: Install 190 Watt Champ FMV LED Floodlights. Benefit immediately from the long life and energy-efficient LED light source. The Champ LED Floodlight is designed to easily adapt to existing SFA6 and SWB6 slipfitters and wall mount brackets. Benefit: Up to 57% more efficient Up to 60,000 hours operating life - 2X to 5X the life of typical HID lamps Similar footprint to existing floodlights Realize a potential $500K in additional energy savings by making the change to Champ FMV LED. Eliminate the need to build scaffolding, rent bucket trucks, and put your maintenance teams in dangerous situations high above the plant floor in order to change out HID lamps. 2

29 Champ FMV LED Series Floodlight Fixtures The Champ FMV LED Series is a perfect example of Cooper Crouse-Hinds innovation. Enhance safety and productivity Cut overall cost of ownership Reduce energy consumption Meet rising environmental standards Engineering Safety & Productivity Safe, reliable heat transfer The heat sink was designed to perform in high ambient temperatures up to +55ºC and as low as -40ºC. The thick walls of the castings make for a tough, rugged housing that keeps the internal driver and LED temperatures down, allowing them to perform flawlessly, and protects them from damage. Separated driver and LED housing allows dust to shed from fixture. Installation and replacement made simple The full-frame yoke was designed to utilize the SFA6 slipfitter and SWB6 wall mount bracket (sold separately), making it ideal for retrofit or new installations. The modular design of the FMV LED allows for easy driver or LED replacement, and allows for the addition of the optional visor or guard in the field. Single cable gland provided with a second plugged cable entry, if an additional cable gland is needed. High efficiency and lumen output High efficiency drivers and LED arrays provide reliable low cost operation in harsh and hazardous environments. Components were chosen to give industry-leading light output from an LED flood. Replaceable drivers and LEDs for ease of maintenance and no lights out feature. Versatile Design Suitable for hazardous location use in gas or dust areas. Can be used for outdoor or indoor applications, and for a wide range of mounting heights depending on model and light level requirement. Optics were specifically designed to give the familiar and industry-accepted butterfly beam light pattern. Optional Equipment Cool (C) and Warm (W) white color temperatures available. Optional visor offered (sold separately) to control light spill. Optional wire guard offered (sold separately) to protect lens from damage. Other options available - consult part numbering guide. 3

30 Champ FMV LED Series Floodlight Fixtures Champ FMV LED offers new solutions for old challenges. It is a new era for Champ fixtures. This luminaire provides the same durability and reliability of a traditional Champ floodlight, coupled with the efficiency, low cost of ownership, and high performance of a Champ LED fixture. High-performance LEDs and a solid-state electronic driver provide light where you need it, at a fraction of the operating cost of HID technologies. THE CHAMP FMV LED FAMILY FMV LED Series Floodlights are designed to provide full-spectrum, crisp, white light. Four versions of the Champ FMV LED are available, providing ideal solutions for a wide range of applications. FMV Model Equivalent MH HID Lamp Energy Savings FMV 5L FMV FMV 9L FMV 11L 100W - 150W 150W - 175W 175W - 250W 250W - 400W Up to 57%! LED SYSTEM High brightness light emitting diode (LED) arrays Color temperature: 3000K (CRI 82) and 5600K (CRI 65) options available Advanced heat sink design ensures LED does not exceed manufacturer s temperature ratings across all specified ambient conditions LM-80 reports available upon request APPLICATIONS Four lumen outputs allow for installation in numerous mounting heights Locations requiring continuous and consistent light levels in extreme ambient temperatures Areas requiring frequent on-and-off of lights Where flammable vapors, gases, ignitable dusts, fibers or flyings are present; indoors or outdoors Where extremely corrosive, wet, dusty, hot and/or cold conditions exist Type 4X, marine, wet locations and hose-down environments Indoor and outdoor area lighting in plants, buildings, and parking areas Manufacturing plants; heavy industrial, chemical, petrochemical or pharmaceutical facilities; platforms; loading docks; outdoor mounted general area lighting You run a refinery with hazardous and non-hazardous areas. The facility has been in operation for 50 years and has a mix of hazardous rated floodlights from several manufacturers of different types and wattages. You re inventorying a large amount of replacement parts and need to cut back on repair costs while maintaining a safe environment for workers. Old Way: Regular maintenance is required to replace burned-out lamps and failed ballasts. You stock several of each type but are finding it hard to purchase some types and are replacing mercury vapor fixtures with metal halide and high pressure sodium. Workers complain about lamp replacement and the color of HPS. New Way: Standardize on Champ FMV LED Floodlights and VMV LED Luminaires. When a lamp or ballast gear burns out, replace the complete fixture with the Champ lineup, or retrofit complete areas one at a time. Workers immediately notice the crisp, white light and can more safely and effectively complete their tasks thanks to the No Lights Out feature. Energy costs drop instantly. Benefit: Inventory decreases tens of thousands of dollars in fixtures and replacements. Your large storage area reduces to only a few drivers on a shelf. Energy usage is cut in half, reducing the plant s energy cost due to lighting from 30% of the overall energy budget down to 15%. Workers are more productive in a safer environment, and less money is wasted on maintenance work so that more money can be spent on the task at hand. 4

31 Champ FMV LED Series Floodlight Fixtures DRIVERS CERTIFICATIONS & COMPLIANCES Engineering Safety & Productivity Model Standard Option 1 Option 2 CHAMP FMV LED BENEFITS Enhance safety and productivity Instant illumination and restrike Better visibility with crisp, white light Minimum T4 temperature rating safely operate in the most hazardous environments and any non-hazardous location Cold temperature operation / no warm-up required No lights out feature if a single LED fails, others will remain lit from other drivers minimum 50% output maintained Reduce operation and maintenance costs Easy installation compact modular fixture attaches onto existing SFA6 and SWB6 Energy-efficient technology use up to ½ the power of standard HID luminaires Provides up to 60,000 hours rated life eliminates need for frequent lamp replacement Contains no mercury or other hazardous substances Reliable performance in any environment Shock- and vibration-resistant solid-state luminaires have no filaments or glass components that could break greatly reduces the risk of premature failure Operating ambient -40ºC to 55ºC Dark sky friendly with optional visor STANDARD MATERIALS 5L - 11L VAC, 50/60 Hz; VDC 347 VAC Model 480 VAC Model NEC and CEC Division 2, Groups A, B, C, D Zone 2 Class II, Groups E, F, G (Pending) Class III Simultaneous Presence Wet location, Type 4X, IP66 UL Standards UL 844 UL1598 luminaires, UL1598A marine CSA Standard CSA C22.2 No. 137 IECEx/ATEX II 3 G Ex na II (Pending) EN :2006, EN :2006 (Pending) II 3 D tc A22 IP66 (Pending) IEC : 2008 (Pending) OPTIONS Suffix to add to Catalog No. Fused (only applies to UNV1 model, not available for 347V or 480V; NOT marine or cul Listed with fusing) S658 ACCESSORIES Catalog No. Sold Separately Bolt-on visor (sold separately) DSV1 Bolt-on wire guard (sold separately) P61 Floodlight slipfitter (sold separately) SFA6 Slipfitter wall mount adapter (sold separately) SWB6 Housing copper-free aluminum with Corro-free epoxy powder coat Lens shatter-resistant glass Gaskets silicone External hardware stainless steel Factory-sealed, no external seals required ELECTRICAL RATINGS FMV 5L FMV FMV 9L FMV 11L Voltage Range, VAC V Hz 347/480V 60 Hz Voltage Range, VDC Input Power (Nom.) Input Amps (Max.) Power Factor >0.85 >0.85 >0.85 >0.85 5

32 Champ FMV LED Series Floodlight Fixtures FMV LED SERIES CATALOG NUMBERING FMV 9L C Y /UNV1 76 S658 Series FMV NEC version with Class/Division ratings Light Source / Intensity 5L 100W - 150W equivalent 150W - 175W equivalent 9L 175W - 250W equivalent 11L 250W - 400W equivalent Color Temperature C 5600K (cool white) W 3000K (warm white) Mounting Y Yoke Voltage /UNV1 100 VAC to 277 VAC 50/60 Hz, 108 VDC to 250 VDC / VAC 60 Hz / VAC 60 Hz Optical Distribution BLANK No optics 76 Floodlight pattern optics included Suffixes S658 Fused; for UNV1 only; not for marine or cul Additional Items (Sold Separately) DSV1 DSV dark sky visor P61 Wire guard factory installed SFA6 Floodlight slipfitter SWB6 Slipfitter wall mount adapter DIMENSIONS [532.9] 21.0 [167.1] 6.6 [552.5] [405.9] 16.0 [14] [120.7] Ø

33 Champ FMV LED Series Floodlight Fixtures Engineering Safety & Productivity PHOTOMETRIC DATA AMBIENT TEMPERATURE Distance in Feet Ft. High; Tilt Angle = 45 Degrees (Isofootcandles) 100Ft 100Ft FMV 5L FMV FMV 9L FMV 11L MAX. TEMP. ºC CL. I, DIV. 2 CL. II, DIV. 1 & 2 / CL. III / SIMU. PRESENCE CL. I, ZONE 2 40 T4 Pending T4 55 T4 Pending T4 40 T4 Pending T4 55 T4 Pending T4 40 T4 Pending T4 55 T4 Pending T4 40 T4 Pending T4 55 T4 Pending T WEIGHTS Distance in Feet MODEL LBS. 5L L L Fc 1 Fc 1.5 Fc 2 Fc 2.5 Fc 3.5 Fc MULTIPLIERS FOR OTHER LED FLOODLIGHTS Luminaire Series Lumen Multiplier Lumens* FMV 5L FMV FMV 9L *FMV 11L output is

34 For more information: If further assistance is required, please contact an authorized Cooper Crouse-Hinds Distributor, Sales Office, or Customer Service Department U.S. (Global Headquarters): Cooper Crouse-Hinds Wolf & Seventh North Streets Syracuse, NY (866) FAX: (315) FAX Orders Only: (866) Canada: Cooper Crouse-Hinds Canada Toll Free: FAX: (800) FAX Orders only: (866) Mexico/Latin America/Caribbean: Cooper Crouse-Hinds, S.A. de C.V FAX: Europe (Germany): Cooper Crouse-Hinds GmbH 49 (0) (0) Middle East (Dubai): Cooper Crouse-Hinds LLC FAX: sales.cch.me@cooperindustries.com Singapore: Cooper Crouse-Hinds Pte. Ltd FAX: chsi-sales@cooperindustries.com China: Cooper Crouse-Hinds Pte. Ltd FAX: cchsales@cooperindustries.com Korea: Cooper Crouse-Hinds Korea CCHK-sales@cooperindustries.com Australia: Cooper Electrical Australia FAX: CEASales@cooperindustries.com India: Cooper India Pvt. Ltd FAX: cchindia@cooperindustries.com Cooper Crouse-Hinds is a registered trademark of Cooper Industries, Inc Cooper Industries, Inc. Your Authorized Cooper Crouse-Hinds Distributor is: Cooper Industries, Ltd. 600 Travis, Ste Houston, TX P: Printed in USA

35 RCDE Series Incandescent Floodlights Cl. I, Div. 1 and 2, Groups C, D Cl. I, Zone 1 Applications: RCDE Incandescent Lighting Luminaires are permanently installed to provide general illumination in locations having hazardous atmospheres, such as: Oil refineries Oil and gasoline loading docks Aircraft servicing docks and shelters Distilleries Paint manufacturing plants Pumping stations Other Groups C and D locations Features: RCDE Incandescent Lighting Luminaires have fixed mountings as follows: RCDE-6 junction box base with four mounting feet or 2" threaded hub (fill sealing chamber with Chico A after conductors are in place) RCDE-6 adjustment allows rotation of 360 horizontally and 75 vertically Locking screws hold housing firmly in position RCDE-10 junction box base with four mounting feet Door which threads into housing includes heat- and impact-resistant lens; door has notches or holes provided for ease of removing or tightening Factory wired leads through explosionproof seal to junction box Adjustment that allows rotation of 360 horizontally and 135 vertically; locking bolts or clamps hold housing firmly in position Temperature Performance Data: (based on 40 C Ambient) 150W 300W 500W RCDE-6 T3B T2B RCDE-10 Certifications and Compliances: NEC/CEC: RCDE Division 1 and 2, Groups C, D; Zone 1 (see photometric data listing) UL Standard: 844 CSA Standard: C22.2 No. 137 (RCDE6 only) CEC/CSA Certified RCDE-6 - Cooper Crouse-Hinds Canada luminaires only. Standard Materials: Body copper-free aluminum Lens glass-, heat- and impact-resistant Standard Finishes: Natural Size Ranges: RCDE fixed mounting 3 /4" hubs Capacity Ranges: RCDE watt, PAR38 or R40; 300 watt, R40 (medium base) RCDE watt, PAR64 Ext. Mog End Prong Ordering Information: After identifying the hazardous area, select the model of lighting luminaire required for that area. Then from the photometric data, select appropriate Cat. No. based on type of mounting desired (Example: RCDE-10 No ). T3C RCDE-6 Description Cat. # Junction box base (2" threaded hub) Junction box base (4 mtg. feet) 44978A 44719B RCDE-10 Description Cat. # Junction box base (4 mtg. feet) 47282A US: CAN: Copyright 2011 Cooper Crouse-Hinds 1113

HID lighting for hazardous areas Champ HID floodlighting. Champ floodlights. HID floodlighting for hazardous areas

HID lighting for hazardous areas Champ HID floodlighting. Champ floodlights. HID floodlighting for hazardous areas HID lighting for hazardous areas Champ HID floodlighting Champ floodlights HID floodlighting for hazardous areas Champ HID floodlights Safe. Reliable. Efficient. Featuring the industry's broadest range

More information

Champ-Pak TM Wall Pack & Floodlight Luminaires Hazardous and Non-Hazardous

Champ-Pak TM Wall Pack & Floodlight Luminaires Hazardous and Non-Hazardous Champ-Pak TM Wall Pack & Floodlight Luminaires Hazardous and Non-Hazardous 7L Description Page No. Application/Selection 866 Floodlights Luminaires Champ-Pak CPMV 867-873 H.I.D. Voyager nr TM Stainless

More information

DMV Series W For Combustible Dusts

DMV Series W For Combustible Dusts L DMV Series 50-250W For Combustible Dusts Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II, Groups E, F, G; Cl.

More information

LMV Series W Low Profile - Medium Base

LMV Series W Low Profile - Medium Base L LMV Series 50-150W Low Profile - Medium Base Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II, Groups E, F, G;

More information

N2MVF Series Compact Fluorescent

N2MVF Series Compact Fluorescent Cl. I, Div. 2, Groups A, B, C, D Cl. II, Groups F, G Cl. III & Simultaneous Presence Marine & Wet Locations, R, 4, 4X; IP56 Applications: Champ Luminaires are used: In areas in which ignitable concentrations

More information

EVLPF Series Compact Fluorescent

EVLPF Series Compact Fluorescent EVLPF Series Low Profile Hazard Gard Luminaires Cl. I, Div. 1, Groups B (GB Suffix), C, D Cl. I, Zone 1, Groups IIB + H2 (GB Suffix), IIB, IIA Cl. II, Div. 1, Groups E, F, G Class III, Simultaneous Presence

More information

Applications. Standard Materials

Applications. Standard Materials Mercmaster III Low Profile Compact Fluorescent Luminaires Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors. Applications Enclosed and gasketed fixtures

More information

UL Listed Available with Cl. I, Div. 2, Groups A, B, C, D rating

UL Listed Available with Cl. I, Div. 2, Groups A, B, C, D rating CCH UX Series LED Exit Signs UL Listed Available with Cl. I, Div. 2, Groups A, B, C, D rating NEMA 4X, IP66 The Cooper Crouse-Hinds CCH UX Series LED Exit Sign combines the strength and durability of die

More information

Pro Series LED Lighting Champ LED floodlights. Champ Pro Series. LED floodlights for heavy industrial

Pro Series LED Lighting Champ LED floodlights. Champ Pro Series. LED floodlights for heavy industrial Pro Series LED Lighting Champ LED floodlights Champ Pro Series LED floodlights for heavy industrial Champ Pro Series Floodlights Safe. Reliable. Efficient. Eaton's Crouse-Hinds offers the broadest portfolio

More information

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED Hazardous Area LED Lighting Hazard Gard LED Luminaires Hazard Gard EVLL LED Hazard Gard EVLL LED Safe. Reliable. Efficient. Featuring the industry's broadest range of LED luminaires for harsh and hazardous

More information

Table 500-3(d) Identification Numbers. Maximum Identification

Table 500-3(d) Identification Numbers. Maximum Identification Exit Signs and Emergency Luminaires Hazardous and Non-Hazardous Description Page No. Exit Signs EXL Series 924, 925 EVLPF(B)-EXD 926 DMVF(B)-EXD 927 Light-Pak TM Emergency Lighting Systems ELPS Series

More information

elevated ambient capability. in installations where moisture, dirt, dust, vibration, corrosion and rough usage are problems.

elevated ambient capability. in installations where moisture, dirt, dust, vibration, corrosion and rough usage are problems. V Series H.I.D s VG, VN, VZ Series Wet Locations Marine Locations NEMA 3,3R,4,4X,7 < VG > < VN > < VZ > Type of Explosion-proof Fixture Wattage Class I Division 2 Group A,B,C,D Class II Division 1,2 Group

More information

Engineering Safety & Productivity. Champ FMV LED Series Floodlight Fixtures Leading the way in LED technology for harsh and hazardous area usage

Engineering Safety & Productivity. Champ FMV LED Series Floodlight Fixtures Leading the way in LED technology for harsh and hazardous area usage Engineering Safety & Productivity Champ FMV LED Series Floodlight Fixtures Leading the way in LED technology for harsh and hazardous area usage Champ FMV LED Series Floodlight Fixtures High-performance,

More information

Engineering Safety & Productivity. Champ FMV LED Series Floodlight Fixtures Leading the way in LED technology for harsh and hazardous area usage

Engineering Safety & Productivity. Champ FMV LED Series Floodlight Fixtures Leading the way in LED technology for harsh and hazardous area usage Engineering Safety & Productivity Champ FMV LED Series Floodlight Fixtures Leading the way in LED technology for harsh and hazardous area usage High-performance, high-brightness Champ FMV LED floodlight

More information

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed! Enhancing Safety + Productivity Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications Now cul Listed! High-performance,high-brightness Champ VMV LED

More information

50-175W VMV Series Champ H.I.D. Luminaires

50-175W VMV Series Champ H.I.D. Luminaires 50-175W VMV Series Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II Groups E, F, G, Cl. III & Simultaneous Presence (HPS 50W, 70W) Application: VMV

More information

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL 25W Hazardous Location Integrated LED Light Fixture - 3294 Lumens - Low Profile - ATEX IEC CSA UL Part #: HAL-19-25W-ITG-LED Page: 1 The Larson Electronics HAL-19-25W-ITG-LED 25 Watt Explosion Proof Low

More information

Enhancing Safety + Productivity. Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications

Enhancing Safety + Productivity. Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications Enhancing Safety + Productivity Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications High-performance, high-brightness Champ VMV LED luminaire brilliantly

More information

EVLED201 36W Led Luminaire. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 14.85

EVLED201 36W Led Luminaire. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 14.85 80 South Street 7596-726, TX Nacogdoches Phone: 96-569-791 Fax: 96-560-685 EVLED201 6W Led Luminaire Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Long Description

More information

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1 Explosion Proof Light - 400 Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1 Part #: EPL-HB-400W-MH Made in the USA The EPL-HB-400W-MH metal halide, hazardous area light fixture from Larson Electronics

More information

EJB Custom-Built Control Panels

EJB Custom-Built Control Panels EJB Custom-Built Control Panels Cl. I, Div. 1 & 2, Groups B*, C, D Cl. I, Zones 1 & 2 Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III UL and cul approved Ex d IIB + H2 T6 Certified to

More information

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE 26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE Part #: EPL-LP-12-LED Page: 1 The EPL-LP-12-LED from Larson Electronics is a Low Profile Explosion Proof

More information

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed! Enhancing Safety + Productivity Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications Now cul Listed! High-performance, high-brightness Champ VMV LED

More information

Enhancing Safety + Productivity. Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications

Enhancing Safety + Productivity. Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications Enhancing Safety + Productivity Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications High-performance, high-brightness Champ VMV LED luminaire brilliantly

More information

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC 208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC Part #: EPL-EMGX-LP-2X48-LED Page: 1 The Larson Electronics EPL-EMGX-LP-2X48-LED Low Profile Explosion Proof

More information

100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof

100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof 100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof Part #: EPLX-HB-100W-RD2-LED-TRC Page: 1 The EPLX-HB-100W-RD2-LED-TRC Explosion Proof Low Bay AC LED light

More information

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable 120W Hazardous Location LED Fixture - 12-24V DC - Modbus TCP/IP - Network Controlled - Dimmable Part #: HAL-ANC-60-120W-ITG-LED-DIMM-1224 Page: 1 The Larson Electronics HAL-ANC-60-120W-ITG-LED-DIMM-1224

More information

VAPORGARD Incandescent Luminaires

VAPORGARD Incandescent Luminaires Cl. I, Div. 2, Groups A, B, C, D (All mounting except stanchion) Wet Locations NEMA 3, 3R L Applications: Vaporgard series incandescent luminaires are used: Indoors or outdoors in industrial locations

More information

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2 Explosion Proof LED Light - Equivalent to 100-150 Watt Metal Halide - Class 1 Division 2 Part #: EPLC2-LED-150W Page: 1 Made in the USA The EPLC2-LED-150W LED hazardous area light fixture from Larson Electronics

More information

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount Part #: EPL-LED-50W-RT-JB2 Page: 1 The Larson Electronics EPL-LED-50W-RT-JB2 Explosion Proof High Bay light

More information

High Mast Series HMAO HMSC

High Mast Series HMAO HMSC High Mast Series HMAO HMSC HOLOPHANE HMAO Series High Mast Series HOLOPHANE HIGH MAST LIGHTING SERIES PROVIDES SUPERIOR BENEFITS FOR ILLUMINATING LARGE AREAS. THE OPTIMIZED LIGHT CONTROL PROVIDED BY THE

More information

REFRACTOPACK. Corrosion resistant construction allows this luminaire to be installed in corrosive and marine outdoor applications.

REFRACTOPACK. Corrosion resistant construction allows this luminaire to be installed in corrosive and marine outdoor applications. REFRACTOPACK The Refractopack luminaire is a versatile unit, combining the options of vertical/horizontal entry, top/side mounting capabilities, and three distinct prismatically controlled light patterns

More information

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style - 0-10V Dimmable Part #: HAL-24-2L-LED-BMSW-D-V2 Page: 1 Made in the USA The Larson Electronics HAL-24-2L-LED-BMSW-D-V2 Hazardous Area

More information

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens Part #: EPLC2-HB-50LED-RT Page: 1 The Larson Electronics EPLC2-HB-50LED-RT Explosion Proof High Bay light

More information

Hazardous Area LED Light -Class 1 Div 2 Groups A, B, C, D and Class 2 Div 2 F,G - 4' 4 lamp

Hazardous Area LED Light -Class 1 Div 2 Groups A, B, C, D and Class 2 Div 2 F,G - 4' 4 lamp Hazardous Area LED Light -Class 1 Div 2 Groups A, B, C, D and Class 2 Div 2 F,G - 4' 4 lamp Part #: HALS-48-4L-LED Made in Texas The Larson Electronics HAL-48-4L-LED Hazardous Area LED Light Fixture is

More information

LED lighting for land-based rigs Pauluhn DLL LED Luminaires. Pauluhn DLL. LED luminaires for land-based drilling

LED lighting for land-based rigs Pauluhn DLL LED Luminaires. Pauluhn DLL. LED luminaires for land-based drilling LED lighting for land-based rigs Pauluhn DLL LED Luminaires Pauluhn DLL LED luminaires for land-based drilling Pauluhn DLL Series LEDs Safe. Reliable. Efficient. Featuring the industry's broadest range

More information

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved 50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved Part #: EPLC2-TRN-50LED-RT Page: 1 The Larson Electronics EPLC2-TRN-50LED-RT Explosion Proof compact

More information

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam 150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam Part #: EPLC2-HB-155W-LED-PND Page: 1 The Larson Electronics EPLC2-HB-155W-LED-PND Explosion Proof High Bay light

More information

MN/DOT Specification Sign Lighting Luminaire With 150 or 250 Watt Metal Halide Lamps 11/05/09

MN/DOT Specification Sign Lighting Luminaire With 150 or 250 Watt Metal Halide Lamps 11/05/09 1. LISTING REQUIREMENTS MN/DOT Specification Sign Lighting Luminaire With 150 or 250 Watt Metal Halide Lamps 11/05/09 1.1. The Luminaire shall be listed by a National Recognized Testing Laboratory (NRTL)

More information

Lighting for Hazardous & Severe Environments

Lighting for Hazardous & Severe Environments Lighting for Hazardous & Severe Environments Petroleum Refining Petrochemical Plants Waste Water Treatment Transportation Facilities Mines and Mining Industrial Manufacturing Rig-A-Lite leads the industry

More information

An Eaton Intelligent Power solution. Champ VMV Connected lighting for hazardous areas

An Eaton Intelligent Power solution. Champ VMV Connected lighting for hazardous areas An Eaton Intelligent Power solution Champ VMV Connected lighting for hazardous areas Get connected with Champ VMV. An Eaton Intelligent Power solution: Remote monitoring and control for use in hazardous

More information

V2LCHF2UNV1 Led Lumnr. Features. Material, Color, and Finish. Long Description. Manufacturer Information EATON CROUSE-HINDS SERIES GTIN

V2LCHF2UNV1 Led Lumnr. Features. Material, Color, and Finish. Long Description. Manufacturer Information EATON CROUSE-HINDS SERIES GTIN 804 South Street 75964-726, TX Nacogdoches Phone: 96-569-794 Fax: 96-560-4685 VCHF2UNV Led Lumnr Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features amperage

More information

Arlington. Full Cutoff. Utility Series

Arlington. Full Cutoff. Utility Series Arlington Full Cutoff Utility Series HOLOPHANE Arlington Full Cutoff The vintage styling of the Arlington Series has adorned urban streets and parks since the early 20th century. Now with a new Nighttime

More information

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required) FLUORESCENT LIGHTING RMS-560.. Series - Fluorescent lighting fixtures TECHNICAL FEATURES RMS.. series lighting fixtures are ideally suited for ON and OFF-SHORE applications and all kinds of industries

More information

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC 25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame - 120-277V AC Part #: EXHL-TRN-LE1-1227 Page: 1 Made in Texas The EXHL-TRN-LE1-1227 from Larson Electronics is an Explosion

More information

Petrolux III. PW Series Wet Locations

Petrolux III. PW Series Wet Locations Petrolux III PW Series Wet Locations HOLOPHANE Wet Location RELIABILITY AND PERFORMANCE ARE KEY CONCERNS IN ALL DEMANDING APPLICATIONS. THE HOLOPHANE WET LOCATION FAMILY OF PRODUCTS IS DESIGNED WITH THE

More information

HOLOPHANE. Vector Luminaire. Optimum visibility. Improved highway safety. Outstanding visibility in critical security applications HL /98

HOLOPHANE. Vector Luminaire. Optimum visibility. Improved highway safety. Outstanding visibility in critical security applications HL /98 Vector Luminaire Optimum visibility Improved highway safety Outstanding visibility in critical security applications HL-9 /98 Vector Meets AASHTO requirements High vertical illumination Up to : spacing

More information

SECTION EXTERIOR LIGHTING

SECTION EXTERIOR LIGHTING SECTION 26 56 00 PART 1 - GENERAL 1.1 DESCRIPTION This section specifies the furnishing, installation, and connection of exterior luminaries, controls, poles and supports. 1.2 RELATED WORK A. Section 26

More information

Code Master Factory Sealed Strobe Luminaires Explosionproof, Dust-Ignitionproof

Code Master Factory Sealed Strobe Luminaires Explosionproof, Dust-Ignitionproof Code Master Factory Sealed Strobe Luminaires Lighting Lighting: Explosionproof Visual Signal Applications Code Master Explosionproof Strobe fixtures are designed to provide safe operation in the presence

More information

50W Explosion Proof LED Light - C1D2, C2D1 - Replacement for 150W Metal Halide - Globe/Guard

50W Explosion Proof LED Light - C1D2, C2D1 - Replacement for 150W Metal Halide - Globe/Guard 50W Explosion Proof LED Light - C1D2, C2D1 - Replacement for 150W Metal Halide - Globe/Guard Part #: EPLC2-HHB-GG-150W-LED Page: 1 Made in the USA The Larson Electronics EPLC2-HHB-GG-150W-LED Explosion

More information

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low Product # Type Date Project Name Project Location Prepared By Capella 2 Construction Y Housing and lens frame are constructed from heavy-duty low Glass Lens is Minimum 1/8 thick thermal and impact resistant

More information

4' 2 Lamp Fluorescent Light Fixture - Emergency Battery Backup - T8 Bulbs - Multi-voltage - CID2

4' 2 Lamp Fluorescent Light Fixture - Emergency Battery Backup - T8 Bulbs - Multi-voltage - CID2 4' 2 Lamp Fluorescent Light Fixture - Emergency Battery Backup - T8 Bulbs - Multi-voltage - CID2 Part #: HALS-EMG-48-2L-T8 Made in the USA The Larson Electronics HALS-EMG-48-2L-T8 Hazardous Area Fluorescent

More information

Explosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips

Explosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips Explosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips Part #: HAL-EMG-48-2L-LED-D-V2 Page: 1 Made in the USA The Larson Electronics HAL-EMG-48-2L-LED-D-V2 Hazardous

More information

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs Part #: HALP-ANC-48-2L-LED-D-V2 Page: 1 Made in the USA The Larson Electronics HALP-ANC-48-2L-LED-D-V2

More information

Full Cutoff. Utility Series

Full Cutoff. Utility Series Full Cutoff Utility Series HOLOPHANE Full Cutoff Utility Series The vintage styling of this series of luminaires has adorned urban streets and parks since the early 20th century. Now with a new Nighttime

More information

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres PRODUCT OVERVIEW Light fittings, boxes & custom built control panels for explosive atmospheres LIGHT FITTINGS, BOXES & CUSTOM BUILT CONTROL PANELS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones

More information

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

ARRAN LED LED FLOODLIGHT. Standard Specification. Features ARRAN LED LED FLOODLIGHT The Arran LED floodlight range is low energy with an instant on output and up to 130,000 maintenance free hours. Specifically designed for applications where moisture, dirt or

More information

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer - 140 - C1D1 - C2D2 - ISO 14644/FS-209E Part #: HALD-24-1X150LED-V2-140DB Page: 1 Made in the USA The HALD-24-1X150LED-V2-140DB from Larson Electronics

More information

CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Enclosure 4X

CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Enclosure 4X Applications Enclosed and gasketed lighting fixtures for use in storage areas, tunnels, subways, chemical plants and other areas where moisture, dirt or corrosive atmospheres are a problem. Suitable for

More information

48W Fluorescent T8 Light w/ Emergency Backup Dimmable Ballast - (2) 2 Foot T8 Lamps - C1D2

48W Fluorescent T8 Light w/ Emergency Backup Dimmable Ballast - (2) 2 Foot T8 Lamps - C1D2 48W Fluorescent T8 Light w/ Emergency Backup Dimmable Ballast - (2) 2 Foot T8 Lamps - C1D2 Part #: HAL-EMG-24-2L-T8-D Page: 1 Made in the USA The Larson Electronics HAL-EMG-24-2L-T8-D Hazardous Area Fluorescent

More information

Explosion Proof LED Light - Equivalent to Watt HID C1D2, UL Listed

Explosion Proof LED Light - Equivalent to Watt HID C1D2, UL Listed Explosion Proof LED Light - Equivalent to 150-175 Watt HID C1D2, UL Listed Part #: EPLC2-LED-175W Page: 1 Made in the USA The Larson Electronics explosion proof LED is designed for use in hazardous work

More information

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67 Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67 Part #: EPSLED-80 Page: 1 Made in Texas The EPSLED-80 Explosion Proof LED Strobe Light from Larson Electronics is UL

More information

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation The Series convection heater, with ratings up to 5000 watts, is designed for heating spaces where explosive substances are or may be present. The is available with either C CSA US or CE/ ATEX approvals.

More information

Hazardous Location LED String Lights - 5 Jelly Jar Lamps - Non Metallic - Chemical Resistant - CID2

Hazardous Location LED String Lights - 5 Jelly Jar Lamps - Non Metallic - Chemical Resistant - CID2 Hazardous Location LED String Lights - 5 Jelly Jar Lamps - Non Metallic - Chemical Resistant - CID2 Part #: HAL-SL-5-LED Page: 1 Made in Texas The Larson Electronics HAL-SL-5-LED Explosion Proof LED String

More information

150W Explosion Proof LED Flood Light - Surface Mount Lumens - C1D V AC

150W Explosion Proof LED Flood Light - Surface Mount Lumens - C1D V AC 150W Explosion Proof LED Flood Light - Surface Mount - 17500 Lumens - C1D1-120-277V AC Part #: EPL-LED-150W-RT Page: 1 The EPL-LED-150W-RT from Larson Electronics is an Explosion Proof High Bay LED Light

More information

PoleStar II HOLOPHANE

PoleStar II HOLOPHANE HOLOPHANE PoleStar II POLESTAR LUMINAIRES PROVIDE A VARIETY OF EXPRESSIONS TO COMPLEMENT ANY ARCHITECTURAL DESIGN WHILE ALSO SATISFYING THE REQUIREMENT FOR A FUNCTIONAL AND MAINTAINABLE LIGHTING SYSTEM.

More information

Explosion Proof 70 Watt Low Profile LED Light Fixture Lumens - C1D1 Group B - Hydrogen Rated

Explosion Proof 70 Watt Low Profile LED Light Fixture Lumens - C1D1 Group B - Hydrogen Rated Explosion Proof 70 Watt Low Profile LED Light Fixture - 6000 Lumens - C1D1 Group B - Hydrogen Rated Part #: EPL-LP-70W-LED-B The Larson Electronics EPL-LP-70W-LED-B Low Profile LED light fixture provides

More information

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord 100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord Part #: EPL-PM-100LED-UVA-150-EPP Page: 1 The EPL-PM-100LED-UVA-150-EPP from Larson Electronics is an Explosion

More information

COMPACT SIZE INTRODUCTION & LOGIC

COMPACT SIZE INTRODUCTION & LOGIC KILLARK COMPACT SIZE INTRODUCTION & LOGIC Class I, Div. 2, Groups A,B,C,D Class l, Zone 2, Groups llc,llb,lla Class II, Div. 1 & 2, Groups E,F,G Class III Suitable for wet locations Marine Rated (US only)

More information

EXH Series Explosionproof Electric Air Heaters

EXH Series Explosionproof Electric Air Heaters EXH Series Electric Air Heaters Cl. I, Div. & 2, Groups C, D Cl. II, Div., Groups E, F, G NEMA 7CD, 9EFG EXH explosionproof electric heaters are used: In areas made hazardous by the presence of flammable

More information

THE COMPLETE GUIDE TO OUTDOOR WALL LIGHTS

THE COMPLETE GUIDE TO OUTDOOR WALL LIGHTS THE COMPLETE GUIDE TO OUTDOOR WALL LIGHTS CONTENTS 1. INTRODUCTION 2. TYPES OF OUTDOOR WALL LIGHTS 3. LIGHT SOURCES IN OUTDOOR WALL LIGHTS 4. FACTORS IN SELECTING OUTDOOR WALL LIGHTS 5. SUMMARY lighting

More information

OUTDOOR LIGHTING. Features and Benefits O Distinctive, European style with a sleek design

OUTDOOR LIGHTING. Features and Benefits O Distinctive, European style with a sleek design HOLOPHANE Pechina THE SLEEK CONTEMPORARY LINES OF PECHINA COMBINED WITH STRONG MECHANICAL ATTRIBUTES MAKE IT A NATURAL FIT FOR MUNICIPAL, ROADWAY AND AREA APPLICATIONS. THE LUMINAIRE, COMBINED WITH COMPLEMENTARY

More information

Explosion Proof UV/Visible Light Fluorescent Fixture - Paint Spray Booth, Rigs - Two Circuit Lamps

Explosion Proof UV/Visible Light Fluorescent Fixture - Paint Spray Booth, Rigs - Two Circuit Lamps Explosion Proof UV/Visible Light Fluorescent Fixture - Paint Spray Booth, Rigs - Two Circuit Lamps Part #: EPL-48-2L-T8-VISUVA Page: 1 The Larson Electronics EPL-48-2L-T8-VISUVA Explosion Proof UV/Visible

More information

300W Low Profile Clean Room LED Light - LED Signal Light - C1D1 - C2D2 - ISO 14644/FS-209E Rated

300W Low Profile Clean Room LED Light - LED Signal Light - C1D1 - C2D2 - ISO 14644/FS-209E Rated 300W Low Profile Clean Room LED Light - LED Signal Light - C1D1 - C2D2 - ISO 14644/FS-209E Rated Part #: HALD-48-2X150LED-V2-C-OXM Page: 1 Made in Texas The HALD-48-2X150LED-V2-C-OXM from Larson Electronics

More information

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion

More information

Post Top Full Cutoff HID

Post Top Full Cutoff HID Post Top Full Arlington Full Post Top Full The vintage styling of this series of luminaires has adorned urban streets and parks since the early 20th century. Now with a new Nighttime Friendly optical design,

More information

MAR2 LED SERIES M A R 2 L E D. Linear LED Lighting for Hazardous Locations

MAR2 LED SERIES M A R 2 L E D. Linear LED Lighting for Hazardous Locations MAR2 LED SERIES Linear LED Lighting for Hazardous Locations Class I, Division 2, Groups A, B, C & D UL 844 Hazardous Locations UL 1598A Marine Outside Type UL 8750 LED Safety CSA C22.2 #250.0-08; CSA C22.2

More information

Vaporproof White LED Light - 10 Watts - Non-Metallic - Corrosion Resistant Lumens

Vaporproof White LED Light - 10 Watts - Non-Metallic - Corrosion Resistant Lumens Vaporproof White LED Light - 10 Watts - Non-Metallic - Corrosion Resistant - 1050 Lumens Part #: VPLED-CRNM-LED10W Page: 1 Made in the USA The VPLED-CRNM-LED10W Vaporproof White LED Light from Larson Electronics

More information

CATALOG NUMBER NAME DESCRIPTION HTL X Keeper 2 40 Watts 120v 5000K 4,000 Lm HTL X Keeper 2 40 Watts 277v 5000K 4,000 Lm 4.

CATALOG NUMBER NAME DESCRIPTION HTL X Keeper 2 40 Watts 120v 5000K 4,000 Lm HTL X Keeper 2 40 Watts 277v 5000K 4,000 Lm 4. SPECIFICATIONS hazloclinear LIGHTING 120 & 277 Voltage KEY FEATURES Two Models: 120 vac or 277 vac. Die Cast aluminum fixture for LED heat dissipation and thermal control. 40 watts, 4000 lumens, Epistar

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:3 Status: Current Date of Issue: 2011-12-07

More information

POINT HELIDECK LIGHTS PRL-EX-LSM LED v4 CLASS I, DIVISION 2 & ZONE 2

POINT HELIDECK LIGHTS PRL-EX-LSM LED v4 CLASS I, DIVISION 2 & ZONE 2 Compliances: ETL Listed Class I, Division 2, Groups A B C D, T6 at -40 deg C to +55 deg C ETL Listed Class I, Zone 2, Groups IIA, IIB+H2, IIC T6 at -40 deg C to +55 deg C ETL Listed to UL 844 & UL 1598

More information

80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup

80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup 80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup Part #: HALP-EMG-48-2L-ITG-LED-V2 Page: 1 Made in Texas The Larson Electronics HALP-EMG-48-2L-ITG-LED-V2 Hazardous

More information

PANELBOARD PROTECTION ON A GLOBAL SCALE

PANELBOARD PROTECTION ON A GLOBAL SCALE PANELBOARD PROTECTION ON A GLOBAL SCALE INTRODUCTION WHY? No matter what environment, location or power requirement, Appleton panelboards have you and your facility covered. From a petrochemical plant

More information

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths Product Description The XB, with ratings up to 5000 watts, is designed for heating spaces where explosive substances are or may be present. The XB is available with either CSA C/US or CE/ATEX approvals.

More information

Hazardous area LED lighting Vaporgard LED Luminaires. Vaporgard LED. Low profi le incandescent replacement

Hazardous area LED lighting Vaporgard LED Luminaires. Vaporgard LED. Low profi le incandescent replacement Hazardous area LED lighting Vaporgard LED Luminaires Vaporgard LED Low profi le incandescent replacement Vaporgard Series LED Lighting Safe. Reliable. Efficient. Eaton's Crouse-Hinds offers the broadest

More information

HOLOPHANE. Vector Luminaire. Optimum visibility. Improved highway safety. Outstanding visibility in critical security applications HL /98

HOLOPHANE. Vector Luminaire. Optimum visibility. Improved highway safety. Outstanding visibility in critical security applications HL /98 HOLOPHANE Vector Luminaire Optimum visibility Improved highway safety Outstanding visibility in critical security applications HL-9 /98 HOLOPHANE Meets AASHTO requirements High vertical illumination Up

More information

Choice of factory set distributions. Thermally set white polyester powder paint. Optional wet location listing

Choice of factory set distributions. Thermally set white polyester powder paint. Optional wet location listing LOBAY The Lobay luminaire combines the efficiency of HID light sources with special lens optics to create an enclosed luminaire that produces a wide variety of lighting distributions. This makes Lobay

More information

POINT ROLLOVER LIGHTS PRL LED HELIDECK SEMIFLUSH LIGHT

POINT ROLLOVER LIGHTS PRL LED HELIDECK SEMIFLUSH LIGHT Compliances: ETL Listed to UL 98 & UL 98A Marine Vessels USA CSA C22.2 No..-4 Canada FAA AC /39-2B Heliport Design Guide ICAO Annex 14, Volume II UK CAA CAP 437, Chapter 4, paragraph 3.1 IMO 9 MODU Code

More information

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 5700 IR Detection of flammable gases and vapours Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive

More information

HL-2449_flg:8 pager 6/17/10 11:19 AM Page 1 Tear Drop LED Series

HL-2449_flg:8 pager 6/17/10 11:19 AM Page 1 Tear Drop LED Series Tear Drop LED Series HOLOPHANE Tear Drop Series LED AS LED TECHNOLOGY CONTINUES ITS RAPID PROGRESSION WITH CHARACTERISTICS SUCH AS IMPROVED EFFICACY AND EXTENDED LIFE; CITIES, TOWNS, VILLAGES, AND INSTITUTIONS

More information

POLESTAR II SERIES HL /01

POLESTAR II SERIES HL /01 POLESTAR PoleStar luminaires provide a variety of expressions to complement any architectural design while also satisfying the requirement for a functional, maintainable lighting system. The distinctive

More information

Circulation Heaters Selection Guidelines

Circulation Heaters Selection Guidelines Selection Guidelines Selecting a Circulation Heater Application Factors Corrosion Policy Selecting the proper circulation heater component requires critical engineering judgement and careful evaluation

More information

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx 60W Flameproof LED Emergency Linear Fixture - 100-250V AC - (2) 30W LED Lamps - ATEX/IECEx Part #: ATEX-HALP-EMG-48-2L-LED-2X30W-R1-220V Page: 1 The Larson Electronics ATEX-HALP-EMG-48-2L-LED-2X30W-R1-220V

More information

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Fixed Gas Detector Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Including e-box for increased safety wiring The Dräger

More information

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen. It uses a high performance

More information

Rating. Class I Div II

Rating. Class I Div II TYPE: LED HAZGLOBE : HZ2 LARGE - 26 WATT SPECIFICATIONS. Housing and Lens Frame: Die cast aluminum for thermal management Lens: Tempered Glass Cage: 0.25 dia Wire; 304 stainless steel Finish: TGIC thermoplastic

More information

Description. Applications

Description. Applications CVEP PDS CVEP Convection for Hazardous Heater For Locations Hazardous Locations Convection Heater 1.8 to 9.0kW (T-2A) 280 C (536 F) 1.6 to 4.0kW (T-3A) 180 C (356 F) 1.8 to 9.0kW (T-2) 1.8 300 C to 9.0kW

More information

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations INSTRUCTION MANUAL E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING

More information

Lighting Solutions. from a Leader in Light Source Technology

Lighting Solutions. from a Leader in Light Source Technology Lighting Solutions from a Leader in Light Source Technology About Venture Lighting Venture Lighting International, an Advanced Lighting company, was founded in 1983 as a metal halide, high intensity discharge

More information

40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated

40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated 40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated Part #: HALD-24-1X40CPR-LED-V2 Page: 1 The Larson Electronics HALD-24-1X40CPR-LED-V2 Explosion Proof LED Fixture provides

More information