Water Leakage Location Detector AD-AS-1LCM-A Operation Manual

Size: px
Start display at page:

Download "Water Leakage Location Detector AD-AS-1LCM-A Operation Manual"

Transcription

1 TTS-KS-W500- Water Leakage Location Detector AD-AS-LM-A peration Manual TATSUTA lectric Wire & able o., Ltd. lectronics Division System Department

2 <<<Important Safety Instructions!!>>> Warning rroneous operation of this water leakage detector not complying with the warning labels or the following warnings may not only lead to possible fatality or serious injury, but also fire, electric shock or failure. Strict Prohibitions! Warnings! Never modify or disassemble the detector. The staff not responsible for operation are forbidden to carry the construction and the regular spot check. Do not touch any internal component of the detector with wet hands. When performing maintenance on the product, avoid using organic solvent. Use soft cotton wastes such as the gauze to wipe gently. heckpoints! heck detector supply voltage and rated voltage before installing. When installing and electrically connecting the detector, follow the instructions in the instruction manual. When performing maintenance and periodical inspection on the detector, follow the instructions in the instruction manual. When using control put contacts, please check the rated loads of the contacts in the following detector specification. Do not install the detector in the following locations! Locations easily accessible to the general public. Locations close to sources of vibration, organic gas or strong electromagnetic induction. Locations with much waste and dust. Locations where there is possibility of water leakage and the temperature and humidity are high. Warranty Before the delivery, this product is subjected to strict quality control and inspection. In the event of spontaneous failure resulting from defective manufacturing, we will repair or replace it according to the following provisions. Warranty Provisions. Warranty period (one year after the delivery date of the product) Should the product fail during the warranty period under normal usage according to the operation manual, we will repair or replace it free of charge. Please contact us using the contact information given below. 2. ases not covered by the warranty: After the period of warranty; 2 Failures due to incorrect usage, and unauthorized repairs and modifications; 2 Failures or damages due to moving, dropping etc. after the purchase; 2 Failures or damages due to fire and natural disasters; 2 Failures not attributable to this product; 2 Fees for on-site service (visiting fee and technical fee). onsultation Shanghai Representative ffice: Room B2/F, Huadu Mansion, No.3 Zhang Yang Road, Pudong New Area, Shanghai, hina, ZIP TATSUTA lectric Wire & able o., Ltd. Tel: Fax: Headquarter: Tokyo Branch: , Iwata-cho, Higashi-saka ity, saka Prefecture 3rd floor, Nihon-Seimei Kawasaki Bldg., -, Minami-machi, Kawasaki Ward, Kawasaki ity, Kanagawa Prefecture Tatsuta lectric Wire & able o., Ltd. System lectronics Division Tatsuta lectric Wire & able o., Ltd. System lectronics Division System Department System Division System Department, Sales Division Tel : Fax : Tel : Fax :

3 Table of contents Page. xplanation of Individual Parts of Water Leakage Location Detector Installation and Handling Precautions Installation 2-2 Handling Precautions 3. Maintenance and Inspection onfiguration of Water Leakage Location Detecting System xternal onnection Power onnection 5-2 Ground onnection 5-3 Water Leakage Sensor onnection 5-4 ontrol utput ontact onnection 5-5 Water Leakage Location Data utput onnection 5-5- onnection Abnormal Water Leakage Location Data utput 6. peration heck Power-n 6-2 heck for Break Detection Function 6-3 heck for Water Leakage Detection Function 7. peration hart Standard peration hart 7-2 peration hart When Alarm Hold Setting is Activated. Indication of Detector Number Detection Sensitivity Setting Buzzer Setting Specifications Ratings -2 ontrol utput ontact Specifications -3 Performance à Attached Drawing utside Dimensions of Water Leakage Location Detector (AD-AS-LM-A) à Attached Drawing 2 xplanation of Individual Parts of Water Leakage Location Detector AD-AS-LM-A) à Attached Drawing 3 xplanation of perational Setting Switches of Water Leakage Location Detector (AD-AS-LM-A) à Attached Drawing 4 xplanation- of Indicators of Water Leakage Location Detector (AD-AS-LM-A) à Attached Drawing 5 xplanation-2 of Indicators of Water Leakage Location Detector (AD-AS-LM-A)

4 First of all, thank you very much for purchasing the Water Leakage Detector AD-AS-LM-A. Before using, read this operation manual carefully to ensure correct operation. Keep this manual in a convenient place for quick reference.. xplanation of Individual Parts of Water Leakage Location Detector location detectors (AD-AS-LM-A)has functions in Drawing. Sensor length and leakage location indicator Power indicator LD Light up when the power is turned on. Alarm indicator LD Flashes when a water leakage is detected. Light up when a break is detected. *Described on page 6 and 7 Alarm ancel Switch Used for canceling alarm when the alarm hold setting is activated for indication or the control put contacts. Detector number indicator Detector number setting switch Buzzer Stop Switch *Described on Pages 9 and 2. *Described on Page 0 peration setting switches Buzzer sounding 2Alarm hold for leakage location indication 3Alarm hold for control put contact 4Shifting the water leakage contact between ontact-a and ontact-b 5Shifting the break relay contact between ontact-a and ontact-b 6Water leakge location data put 7Detection sensitivity change *Described on Page 5,6,,9,0 and. Switch for the adjustment of detection sensitivity *Do not change the factory setting Terminal block (M3) Power switch *Described on Page 3 and 6. Drawing xplanation of Individual Parts of Water Leakage Location Detector --

5 2.Installation and Handling Precautions 2- Installation The Water Leakage Position Detector (AD-AS-LM-A) shall be securely installed in a strong housing, on the wall, etc. inside a building.) Be sure to follow the instructions below when installing this product. ) Avoid installing the detector in any location subject to high temperature and high humidity, excessively dusty environments and corrosive gas environments. 2)Install the detector in a location that is free from vibration, away from sources of interference such as power switches, and convenient for quick maintenance and regular inspection. 3)Install the inductive sensor using the suitable fixator, according to installation location and environment. 4) onsult with us in case the inductive sensor is used in places easy to be affected by electromagnetic induction. 5) Do not insert foreign matters, including screw-drivers into gaps in the detector. 6) Do not use the sensor as electric wire. 7) Never use inductive sensors other than our product AD-LS Sensor. This will cause serious errors in the location detection function. So pls make sure not to use or use together with any sensor other than AD-LS sensor. 2-2 Handling Precautions )Use the detector in an environment with a temperature range between -0 and 50 and a humidity range between 35% to 5%. 2)Do not use the detector in any location close to sources of vibration and harmful gas, and strong electromagnetic inductive power sources. 3)After installation, be sure to apply the insulating sheet to the terminal block, and cover the surface cover plate, meanwhile confirm the operation. 3. Maintenance and Periodic Inspection 2When inspecting the facilities, conduct inspections in conformance with the operation check items described in hapter 6. Note)During inspection of the detector, the control put contacts are functioning, so if the control put contacts are used, disconnect the wiring or connect temporary wiring in order not to affect other devices. 2If the surface and inside of the sensor is adherent with water repellant substances like oil, normal operation is possible to be interfered. Please pay attention. 2If the sensor is tainted with dirty water, please replace it in time. -2-

6 4. Structure of Water Leakage Location Detecting System The water leakage location detecting system consists of: location detector (AD-AS-LM-A) 2 sensor (AD-LS) 3 Break detection terminal (ZT-L2) For connections on the terminal block, refer to Attached Drawing 2. location dete AD-AS-LM-A ctor location data put (4-20mA put) ontact put *Power source A00V~ Grounding Joint box A240V Water Leakage Break Detection General instrumentation cables: AD-LS Sensor Terminal ZT-L2 Triplex, twisted wiring conductor: 0.5mm 2 min. in area and 00m max. in length Triplex, single wiring conductor: φ0.mm min. and 00m max. in length Drawing 2 Water Leakage Location Detecting System entral monitoring board Sequencer signal to ontrol circuit 5. xternal onnection AD-AS-LM-A has a terminal block as shown in Drawing 3. (Make connections securely in conformance to Sections to 5.) Terminal block (M3) Power A5~264V Inductive sensor 2 3 Water leakag Break M N M N + -LP - Power source Inductive sensor AD-LS contact (*ontact: a) Break contac (*ontact:a) 4-20mA put A5~ 264V Grounding Braided wire Insulated wire Resistance wire M N M N + - Drawing 3 Lay Drawing of Terminal Block 5-.Power onnection A00~240V(Variation range in power voltage: A5~264V) Before connection, check that the power supply voltage is within the range of use, then, connect it securely to the terminal block. *Inputting a power voltage side the range of use may cause malfunctions and failure of the detector, so care should be taken. 5-2 Ground onnection Be sure to ground for interference prevention. -3-

7 5-3 Sensor onnection The structure of the Water Leakage Sensor (AD-LS Sensor) used for the Water Leakage Location Detector (AD-AS-LM-A) are shown in Drawing 4 and Table 4. Shapes and functions of each wire vary, so care should be taken when connecting to the detector. Refer to Drawing 5 *Incorrect wiring will result in inaccurate indication of water leakage locations or break alarm put. *While carrying wiring, make sure that the power of the detector is switched off. 4mm max. lectrode-3 resistance wire lectrode- (braided wire) lectrode-2 insulated wire xternal braiding Drawing 4 AD-LS Sensor Structure lement lectrode lectrode 2 lectrode 3 xternal braiding Table AD-LS Sensor onfiguration onfiguration 0.33-mm 2 tinned soft copper wire covered with red plastic braided thread 0.5-mm 2 tinned soft copper wire insulated with green plastic φ0.4 resistance wire covered with white plastic braided thread White plastic braided thread Power A5~264V Sensor 2 3 Break M N M N -LP + - Power source Sensor AD-LS contact (*ontact: a) Break contact (*ontact:a) 4-20mA p A5~ 264V Grounding Braided wire Insulated wire Resistance wire M N M N + - Drawing 5 Terminal Block for Sensor onnection -4-

8 5-4 ontrol utput ontact onnection There are puts for water leakage and break put connections (ontact a), use them if external control is needed. (Refer to Drawing 6.) Power source A5~264V Sensor 2 3 Water leakag M Break M -LP N N + - Power source Sensor AD-LS contact Break contact (*ontact: a) (*ontact: a) 4-20mA put A5~ 264V Grounding Braided wire Insulated wire Resistance wire M N M N + - Drawing 6 ontrol utput ontact contacts M-N: losed when water leakage is detected. Break contacts M-N : losed when a break is detected. *ontact operation hanging operational setting switches shifts ontact a to ontact b. (Refer to Drawing 7.) N.4 The water leakage ontact a is shifted to ontact b N.5 The break ontact a is shifted to ontact b Drawing 7 Setting for Water Leakage and Break ontact peration *Alarm hold Turning the peration switch 3 activates the alarm hold setting.(refer to Drawing.) Turning no.3 switch Alarm hold setting are activated for water leakage and break contacts. Drawing Alarm Hold Setting for Water Leakage and Break ontacts -5-

9 5-5 Water Leakage Location Data utput onnection 5-5- onnection The AD-AS-LM has a function that puts the water leakage location by D electrical current. *Use an analog input device with an input resistance of 500 Ω or lower. Power A5~264V Power A5~ 264V Grounding Braided wire Sensor 2 3 Sensor AD-LS Insulated wire Resistance wire M N ontact (*ontact :a) M N Break M Break contact (*ontact :a) M N N -LP mA put N mA put setting change Drawing 9 Water Leakage Location Data utput onnection Drawing 0 Water Leakage Location Data utput Setting utput specifications Normal sensor put current = 4 (ma) Sensor put current in the case of sensor break detection = 20 (ma) utput current in the case of water leakage detection = x water leakage location indication (m) ma ±% *peration setting switches are used to change operations in water leakage detection. utput current in the case of water leakage detection = 6 water leakage location indication(m)/ 250(m)+ 4mA ± % Abnormal Water Leakage Location Data utput In the case of abnormal water leakage location data put, an indication of 0 is added on the 3-digit, 7-segment LD. (Refer to Drawing.) This may result from the causes described below. heck the facilities. Detector: Wiring connection among external analog input devices is broken or the input resistance for external analog input devices is more than 500Ω. 2The internal power inside the detector for Alarm LD Under normal sensor condition Indication of the Sensor length Indication for error In the case of break detection Alarm LD status Break indication Indication for error Alarm LD status In the case of water leakage detection Indication of the Sensor length up up up up Indication location indication for error Alarm LD status Flashing Drawing Indications in the ase of Abnormal Water Leakage Location Data utput -6-

10 6. peration heck 6- Power-n When the detector is powered on, the Power Indicator LD and the 7-segment LD light up. (Refer to Drawing 2.) In the case that the LD does not light up, the detector may be of order. Power off the detector promptly and contact the manufacturer. up up Drawing 2 Power-n peration 6-2 heck for Break Detection Function ) After powering off the detector, remove the water leakage sensor from the trunk terminal block and then power on the detector. 2) The buzzer sounds, the Alarm Indicator LD flashes and the contacts (for break detection) function. 3) The 3-digit, 7-segment LD indicates ---.(Refer to Drawing 3.) 4) After the operation check, power off the detector and then connect the sensor to the terminal block again. up Drawing 3 Indication in the ase of Break Detection 6-3 heck for Water Leakage Detection Function ) Drop tap water into the water leakage sensor. 2) The buzzer sounds, the Alarm Indicator LD lights up and the contacts (for water leakage detection) function. 3) The 7-segment LD indicates as shown in Drawing 4. xample: in the case in which a sensor with a length of 250 meters connected and a point at 20 meters wetted. 4) Wipe the tap water dropped on the sensor with dry rags, etc. and check that the water leakage status returns to normal. Flashing: The water leakage location is indicated. : The sensor length isindicated. Indication of the Sensor length location indication Alarm LD status Flashing Drawing 4 Indication in the ase of Water Leakage Detection -7-

11 7. peration hart 7- Standard peration hart (Factory setting) Refer to Drawing-5 for the operation chart. Power Power Indicator LD up detection function Break detection function Alarm Indicator LD Flashing up Buzzer Stop Switch Buzzer sounding ontrol put contact (water leakage: M-N) pen losed pen ontrol put contact (break: M-N) pen losed pen Sensor length indication No indication *Indication Indicating --- location indication No indication * Indication No indication location data put 4-20mA put water leakage location indication(m)ma or 4+6 water leakage location indication(m)/250(m)m 20mA 4mA 4mA 4mA * The sensor length and the water leakage location is indicated alternately. (See Attached Drawing-4) Drawing-5 peration hart- Buzzer Pressing the buzzer stop switch stops the buzzer. When the system detects another water leakage or a break, the buzzer sounds again. Turning the No. operational setting switch to set the buzzer to constant sound. (Refer to Drawing 6) N. Sounding of buzzer is prevented. Drawing-6 Buzzer Setting --

12 7-2 peration hart When Alarm Hold Setting is Activated hanging operational setting switches activates the alarm hold setting for indication and control put contacts. For the operation chart, refer to Drawing N.2 The condition is changed to that in which the alarm hold setting for the water leakage location indication is activated N.3 The condition is changed to that in which the alarm hold setting for the control put contact is activated Drawing 7 Alarm Hold Setting Power Power Indicator LD up detection function Break detection function Alarm indicator LD Flashing up Buzzer Stop Switch Buzzer sounding Alarm cancel switch ontrol put contact (water leakage:m-n) pen losed pen ontrol put contact (break:m-n) pen lose pen Sensor Length indication No indication * Indication Indicating --- *2 Indication location indication No indication * Indication No indication location data put 4-20mA put water leakage location indication(m)ma or 4+6 water leakage location indication(m)/250(m)ma 20mA 4mA 4mA 4mA * The sensor length and the water leakage location are indicated alternatively. (Refer to Attached Drawing 4) *2 For the break indication, the alarm status in not held. Drawing peration hart- -9-

13 3 Regarding the operation when the alarm hold setting is activated When the alarm hold setting is activated, the alarm status is held until the cancel switch is pressed. lectric power failure or power-off returns the contact operation status to that when the power source is shut off. When alarm holding is not set, refer to Drawing -5 and peration hart. Regarding the Alarm Indicator LD The Alarm Indicator LD does not maintain alarm status. The Alarm Indicator LD goes when the system detects recovery from water leakage status and break status. If the Alarm Indicator LD continues to flash even after the water leakage sensor is wiped with rags etc., this indicates that water leakage may occur at multiple locations. After completely drying the water leakage sensor at the location that the indicator displays, press the alarm cancel switch. * If drying is insufficient, deviation may occur between the water leakage location displayed after the alarm cancel switch is pressed and the actual water leakage location.. Indication of Detector Number Related settings are necessary to be carried if it is expected to indicate number on the indicator, in the case of multiple indicators are used together. Turn the Detector Number Setting Switch and select a number that you want to indicate. (Refer to Attached Drawing 9) The detector number is indicated on the leftmost 7-segment LD.(~9,A,B,,D,,F) *The factory setting is 0 (no indication). Indication of detector number 漏水位置検知器 AD-AS-LM-A Detector Number Setting Switch A 電源 5 4 B 警報 0 2 F D ブザー停止 警報解除 TATSUTA lectric Wire & able o.,ltd Drawing 9 Indication of Detector Number 9. Detection Sensitivity Setting hanging operational setting switches changes the detection sensitivity level. (Refer to Drawing 20.) *The water leakage sensor detects water leakage even it is caused by only a small amount of water (condensation, for example). Therefore, if the sensor is installed in a location subject to high temperature and high humidity, set the sensitivity level lower. * In the case in which it is necessary to detect fluid with high electrical resistance, such as pure water, in an environment where the temperature and humidity are stable, such as a clean room, it is recommended to set the sensitivity level high. Factory setting Standard sensitivity: approx.25kω Low sensitivity approx.0kω High sensitivity approx. 50kΩ Highest sensitivity approx. 00kΩ N.7 N. N.7 N. N.7 N. Drawing-20. Detection Sensitivity Setting -0- N.7 N.

14 0. Buzzer Setting Turning the No. operational setting switch to set the buzzer to constant sound. (Refer to Attached Drawing 2.) N. Sounding of buzzer is prevented. Drawing-2. Buzzer Setting. Specifications -. Ratings For ratings, see Table 2. Table 2 Ratings Item Specifications Rated voltage A00~240V Supply voltage fluctuation A5~264V Power consumption 5W max. ontrol put grounding *heck Subsection -2, control put contact specifications. Sensor applied voltage A5. 5V max. Working ambient 0 to 50 (no icing) temperature Working ambient humidity 35%RH to 5%RH (no condensation) -2 ontrol put contact specifications For control put contacts,refer to Table 3. Table 3 ontrol utput ontact Specifications Item Resistance load Inductive load Rated load A25V 0. 4A D 30V 2. 0A A25V 0. 2A D 30V. 0A Minimum load D0mV 0μA (reference value) (Relay contact: G6-34P-US Sample values by MR orporation) --

15 -3 Performances For performance parameters, refer to Table-4. Table 4 Performances Item Specifications Number of sensor circuits Length of sensor connection to 250m Detecting sensitivity level setting Low Standard High Highest detection sensitivity 0kΩ±20% 25kΩ±20% 50kΩ±20% 00kΩ±20% Sensitivity in the case of recovery from water leakage 6kΩ±20% 37kΩ±20% 6kΩ±20% 25kΩ±20% Detecting accuracy ~00m : ±m 0~250m : Sensor length ± % Surface panel operation switch function Surface panel LD indication Surface panel 7-segment LD indication Surface panel operation setting switch Buzzer ontrol put contact location data put Withstand voltage Insulation resistance Noiseproofing property Buzzer stop switch: Alarm cancel switch: Power source indication, green: (lighting up) Alarm indication, red: (flashing in the case of water leakage detection) (lighting up in the case of break detection) Detector number indication: digit ( to 9, A, b,, d, and F) Sensor length and water leakage location indication: 3 digits, in meters Used for setting change of indication, control put contacts, detection sensitivity level, etc. Average sound pressure: 90 db/0 cm (sample value by manufacturer) ontact onfigu ration ontacts (For specifications, refer to Section 3-3.) : for a Break: for a * Setting change of the operation switches shifts to ontact b ma current loop put (external load resistance: 500 Ω max.) x Under normal sensor conditions: 4 ma In the case of sensor break detection: 20 ma In the case of water leakage detection: x water leakage location indication (m) ma ± % * hanging operational setting switches changes operation in the case of water leakage detection. (Refer to Attached Drawing 3.) In the case of water leakage detection:6 x water leakage location indication (m) / 250 (m) + 4 ma ± % A 500V (50/60 Hz)/ minute (between the power source terminal and the body case) 0 MΩ min. (with D 500V Megger)/ minute (between the power source terminal and the body case) ±500V Pulse width: μs (noise simulator)/ minute (between each phase and the grounding terminal) utside dimensions W06 x H95 x D6 (unit: mm) (Refer to Attached Drawing.) Weight and color Approx. 300 g, grey -2-

16 H Attached Drawing- 25 H G G F PWR F 0 BUZZR RST STP ALARM D D 35 B + - B A Approved by hecked by Prepared by Scale Unit Prepared on -/- mm Tatsuta lectric Wire & able o., Ltd. Name No. Drawing Water Leakage Location Detector AD-AS-LM-A Appearance Dimension Drawing TTS-KS-W325-0 A

17 Attached Drawing-2 H Detector number indication H Detector number setting switch AB DF Sensor length and water leakage indication G peration setting switch Power source indication LD G PWR Alarm indication LD F Detection sensitivity adjustment switch *Do not change factory setting 割り基板が重なる部分 BUZZR STP RST ALARM Alarm cancel switch F Power switch Buzzer stop switch Terminal block(m3) 電源 A5 ~264V Sensor 漏水断線 -Loop 2 3 M N M N + - D D Power A5V~ A264V Grounding Braided wire Sensor AD-LS Insulated wire Insulated wire contact (*ontact: a) M N Break contact (*ontact: a) M N 4-20mA put + - B B A Approved by hecked by Prepared by Scale -/- Unit mm Prepared on Tatsuta lectric Wire & able o., Ltd. xplanation of various parts of the Water Leakage Location Detector AD-AS-LM-A Name Drawing No. TTS-KS-W326-0 A

18 Attached Drawing-3 No Factory setting peration Buzzer soundi : Activated : Not activated Alarm hold for water leakage location indication : Not activated : Activated Alarm hold for water leakage and break relays : Not activated : Activated peration between ontact a and onatct b for water leakage relay : ontact a : ontact b peration between ontact a and ontact b for break relay : ontact a : ontact b 4-20mA operation in the case of water leakage detection: water leakage location indication (m) ma in the case of water leakage detection: 4+6 water leakage location indication (m)/250 ma x: is located at 00m : = 9mA x: is located at 00m : /250 = 0.4mA 7 Detection sensitivity shifting (7) () - Standard sensitivity Approx. 25kΩ - Low sensitivity Approx. 0kΩ - High sensitivity Approx. 50kΩ - Highest sensitivity Approx. 00kΩ *hanging setting of switches corresponidngly chang operations such as indication and relay. If it is changed to no function status, no corresponding operation is activated,so care should be taken. Approved by hecked by Prepared by Scale Unit Prepared on -/- mm Name Water Leakage Location Detector AD-AS-LM-A peration setting switch instructions Tatsuta lectric Wire & able o., Ltd. No. Drawing TTS-KS-W327-0

19 Attached Drawing-4 Indication under normal sensor conditions Under normal sensor conditions Indicating the sensor length Alarm LD status Indication in th ecase of break detection In the case of break detection Indication for break up Alarm LD status up Indication in th ecase of water leakage detection : sensor length indicated Flashing: water leakage location indicated In the case of detection Alarm LD status sensor length Indicating Indicating the water leakage location Flashing Indication for abnormal water leakage data put Under normal sensor conditions Indicating the sensor length Indication for error Alarm LD status In the case of break detection Indication for break Indication for error In the following cases, an indication of 0 is added: Detector:Wiring conncetion between external analog input devices is broken, or the input resistance for the external analog input devices is more than 500Ω. 2The internal power source inside the detecot for Alarm LD status In the case of water leakage detection up Indicating the sensor length up up location indication up Indication for error 4-20mA put is of order. Alarm LD status Flashing Approved by hecked by Prepared by Scale Unit Prepared on -/- mm Name Water Leakage Location Detector AD-AS-LM-A Indication instruction- Tatsuta lectric Wire & able o., Ltd. No. Drawing TTS-KS-W32-0

20 3 H Attached Drawing-5 Detector Number Indication H G Detector Number Indication G F Detector number setting switch A F PWR 5 4 B ALARM 0 2 F D BUZZR STP RST D D Use this function in the case it is necessary to indicate the number of each detector,when multiple detectors are used together. Turn the Detector Number Setting Switch to select a number that you want to indicate. The detector number is indicated on the leftmost 7-segment LD. ( to 9 and A, B,, D,, F can be indicated.) *The factory setting is 0 (no indication). B B A Approved by hecked by Prepared by Scale Unit Prepared on -/- mm Tatsuta lectric Wire & able o., Ltd. No. Name Drawing Water Leakage Location Detector AD-AS-LM-A Indication instruction-2 TTS-KS-W329-0 A

Specification Document. Single-circuit Embedded Water Leakage Detector AD-AS-1BM (RoHS-directive-compatible)

Specification Document. Single-circuit Embedded Water Leakage Detector AD-AS-1BM (RoHS-directive-compatible) To: Specification Document Single-circuit Embedded Water Leakage Detector AD-AS-1BM (RoHS-directive-compatible) Date:( ) System Equipment Division Electronic Materials & System Equipment

More information

Specification Document. Color-changing Recovery Type Water Leakage Sensor AD-RS

Specification Document. Color-changing Recovery Type Water Leakage Sensor AD-RS TS-KS-W11608-1 To: Specification Document Color-changing Recovery Type Water Leakage Sensor AD-RS Date:( ) System Equipment Division Electronic Materials & System Equipment Group TATSUTA

More information

Specification Document. Heat-resisting Type Water Leakage Sensor FR-AD

Specification Document. Heat-resisting Type Water Leakage Sensor FR-AD TS-KS-W1164-8 To: Specification Document Heat-resisting Type Water Leakage Sensor FR-AD Date:( ) System Equipment Division Electronic Materials & System Equipment Group TATSUTA Electric

More information

Specification Document. Single-circuit Water Leakage Detector AD AS 1AM (RoHS-directive-compatible)

Specification Document. Single-circuit Water Leakage Detector AD AS 1AM (RoHS-directive-compatible) TS-KS-W1019-0 To: Specificati ocument Single-circuit Water Leakage etector S 1M (RoS-directive-compatible) ate:( ) System quipment ivisi lectric Materials & System quipment roup TTSUT lectric

More information

AUR300C. Advanced Ultraviolet Burner Controller

AUR300C. Advanced Ultraviolet Burner Controller No. CP-SS-1807E AUR300C Advanced Ultraviolet Burner Controller Overview The AUR300C is a burner controller with a dynamic selfchecking function and is used in combination with the AUD300C or AUD500C Advanced

More information

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl enproteko.com Temperature Monitoring Relay K8AB-TH Compact and Slim Relay Ideal for Temperature Alarms and Monitoring Excessive increases can be prevented and abnormal s can be monitored. Temperature monitoring

More information

Ionizer (Static Remover) STABLO-EX Instruction Manual

Ionizer (Static Remover) STABLO-EX Instruction Manual 321-56879-21E Jan. 2009 For Electronic Balances Ionizer (Static Remover) STABLO-EX Instruction Manual Read the instruction manual thoroughly before you use the product. Retain this instruction manual for

More information

Warning Caution. Safety Precautions (Be sure to read these precautions before using our products.)

Warning Caution. Safety Precautions (Be sure to read these precautions before using our products.) INSTRUCTION MANUAL Infrared Temperature Sensor RD-715-HA No. RD71JE1 2013.09 Preface Thank you for purchasing our Infrared Temperature Sensor RD-715-HA. This manual contains instructions for the mounting,

More information

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD Corona Corporation This instruction manual contains important information for safe use of this device. Keep this instruction manual

More information

TEMPERATURE CONTROLLER

TEMPERATURE CONTROLLER TEMPERATURE CONTROLLER E5CX(-H) DIN-sized super-compact (48 x 48-mm) Temperature Controller Featuring Advanced PID Control Advanced PID control with two degrees of freedom improves stability and response

More information

SA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection

SA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection SA00 SA00 SA00 SA00 Temperature Limit ontroller SA00L FM APPROVED SA00L General Description The SA00L is a FM approved high limit or low limit controllers. The SA00 is a socket mounting type temperature

More information

IMR IX176 Portable Gas Detector User Manual

IMR IX176 Portable Gas Detector User Manual IMR Portable Gas Detector User Manual Read this manual carefully before using this device. (727) 328-2818 / (800) RING-IMR Fax: (727) 328-2826 www.imrusa.com Ver. 1.0A4 CONTENTS SERVICE GUIDELINES... 3

More information

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side s Frost detector for use on the air side QAF64.2-J QAF64.6-J With active capillary tube sensing element for acquiring the lowest temperature within a range of 0 15 C With startup function Operating voltage

More information

DSSLF2X04H 2 IN 1. Intelligent Lead Free Soldering Station. OPERATION and MAINTENANCE MANUAL

DSSLF2X04H 2 IN 1. Intelligent Lead Free Soldering Station. OPERATION and MAINTENANCE MANUAL 401H000898 DSSLFX04H Intelligent Lead Free Soldering Station IN 1 OPERATION and MAINTENANCE MANUAL Thank you for purchasing a lead free soldering station. It is designed for lead free soldering. Please

More information

DSSHP06G Intelligent Lead Free Soldering Station INSTRUCTION MANUAL

DSSHP06G Intelligent Lead Free Soldering Station INSTRUCTION MANUAL DSSHP06G Intelligent Lead Free Soldering Station Sensor in front High frequency heating Digital Calibration Rapid recovery of temperature INSTRUCTION MANUAL Thank you for purchasing this lead free soldering

More information

MARUYASU INDUSTRIES CO.,LTD.

MARUYASU INDUSTRIES CO.,LTD. Instruction Manual MARUYASU INDUSTRIES CO.,LTD. TUBE CORE HEAT EXCHANGER Thank you very much for your purchasing our tube core heat exchanger. Read this instruction manual carefully before using our products.

More information

Advanced Ultraviolet Burner Controller

Advanced Ultraviolet Burner Controller No. CP-SS-7E Advanced Ultraviolet Burner Controller Model AUR300C/AUR30C Overview The AUR300C Advanced Ultraviolet Burner Controller and AUR30C Advanced Ultraviolet Burner Controller with Communication

More information

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system INSTRUCTION MANUAL 1MN0110 REV. 0 operates with ISO9001 certified quality system TECSYSTEM S.r.l. 20094 Corsico (MI) Tel.: +39-024581861 Fax: +39-0248600783 http://www.tecsystem.it R. 1.1 25/08/16 ENGLISH

More information

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller No. CP-SS-7E Overview The AUR300C is a burner controller with a dynamic selfchecking function and is used in combination with the AUD300C or AUD00C Advanced Ultraviolet Flame Detector. This AUR300C controls

More information

Intelligent Lead Free Soldering Station OPERATION and MAINTENANCE MANUAL

Intelligent Lead Free Soldering Station OPERATION and MAINTENANCE MANUAL Intelligent Lead Free Soldering Station Sensor in front High frequency heating Digital Calibration Rapid recovery of temperature OPERATION and MAINTENANCE MANUAL Thank you for purchasing a lead free soldering

More information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information Liquid Level Sensor EK-L CSM_EK-L_DS_E_4_ Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to 11 mm or 1 to mm Built-in

More information

JW SERIES. Three Phase Thyristor Regulator PSE-351

JW SERIES. Three Phase Thyristor Regulator PSE-351 JW SERIES Three Phase Thyristor Regulator JW Series is compact lightweight three-phase control thyristor regulators enabling high-density instrumentation. The methods of control are divided into two ways,

More information

ISHIDA CO., LTD. Do not carry out installation, operation, service or maintenance until thoroughly understanding the contents of this manual.

ISHIDA CO., LTD. Do not carry out installation, operation, service or maintenance until thoroughly understanding the contents of this manual. Do not carry out installation, operation, service or maintenance until thoroughly understanding the contents of this manual. Keep this manual available at all times for installation, operation, service,

More information

RS Pro Infrared Temperature Sensor

RS Pro Infrared Temperature Sensor Instruction Manual RS Pro Infrared Temperature Sensor Stock Number: 161-8103 Introduction The RS Pro Infrared Temperature Sensor is a device for measuring the temperature of the surface of a solid or liquid

More information

AE500 Instruction Manual

AE500 Instruction Manual Digital Indicator with Alarm function AE500 Instruction Manual IMAE01-E8 Thank you for purchasing this RKC product. In order to achieve maximum performance and ensure proper operation of your new instrument,

More information

IMR EX610. Portable Gas Detector. Operation Manual

IMR EX610. Portable Gas Detector. Operation Manual IMR EX610 Portable Gas Detector Operation Manual IMR Environmental Equipment, Inc. 3634 Central Ave. St. Petersburg, FL 33711 Phone: 727-328-2818 email: info@imrusa.com Read this manual carefully before

More information

Tissue-Tek TEC Plus Cryo Console OPERATING MANUAL

Tissue-Tek TEC Plus Cryo Console OPERATING MANUAL Tissue-Tek TEC Plus Cryo Console OPERATING MANUAL Sakura Finetek Japan Co., Ltd., Tokyo 103-0023, Japan Sakura Finetek U.S.A., Inc., Torrance, CA 90501, USA Sakura Finetek Europe B.V., Zoeterwoude, Netherlands

More information

Model Number Structure

Model Number Structure Element Burnout Detector Accurate Detection of Element Burnout Regardless of Capacities Accurately detects a burned heater element or elements incorporated by a molding machine or packing machine and outputs

More information

Operating Instructions

Operating Instructions Operating Instructions Laboratory Freezer SF-L6111W Please read these instructions carefully before using this product, and save this manual for future use. See page 18 for all Model No. 0 Note: 1. No

More information

UV Flame Supervision System

UV Flame Supervision System 7 783 UV Flame Supervision System DETACTOGYR LFE50 Series 02 ISO 9001 The LFE50 is a self-checking UV flame supervision system designed for use with continuously operating burners or for burners running

More information

testo Leakage detector for gas Instruction manual

testo Leakage detector for gas Instruction manual testo 316-2 Leakage detector for gas Instruction manual 2 Safety and environment Safety and environment On this document > Read this document through carefully, and familiarize yourself with the product

More information

OPERATION AND MONTAGE MANUAL ROOF FANS

OPERATION AND MONTAGE MANUAL ROOF FANS NO RFEC/U/2017-1 (EN) (valid since 18.08.2017) ROOF FANS RF/EC...-... / RFV/EC...-... Venture Industries Sp. z o.o. is not responsible for any damage caused by improper use of the fan and reserves the

More information

Data Sheet Sensor: IRA-S210ST01 Lens: IML-0685 / IML Sensor : IRA-S210ST01 Lens : IML-0685/0688. Pyro Electric Infrared Sensor Fresnel Lens

Data Sheet Sensor: IRA-S210ST01 Lens: IML-0685 / IML Sensor : IRA-S210ST01 Lens : IML-0685/0688. Pyro Electric Infrared Sensor Fresnel Lens Sensor : IRA-S210ST01 Lens : IML-0685/0688 Pyro Electric Infrared Sensor Fresnel Lens Features Excellent S/N Low voltage operation available Applications Intrusion Detectors Lighting Automation Please

More information

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector. Color Mark Sensor Detects laminated or light-dispersing objects in stable operation without being influenced by mirror reflection. Double indication of the detection level and threshold level allows easy

More information

AnyWireASLINK System Products Guide

AnyWireASLINK System Products Guide READER/WRITER MADE IN JAPAN System Products Guide S-K1117 -M -3012 is a registered trademark of OMRON Corporation. [Notes on Safety] Precautions that must be observed in order to use this system safely

More information

DIGITAL INDICATOR JIR-301-M

DIGITAL INDICATOR JIR-301-M DIGITAL INDICATOR JIR-301-M Instruction Manual Preface Thank you for purchasing our digital indicator JIR-301-M. This manual contains instructions for the mounting, functions, operations and notes when

More information

FagronLab NP-1 UV. Negative pressure workbench. User Manual

FagronLab NP-1 UV. Negative pressure workbench. User Manual Negative pressure workbench User Manual Table of contents 1. Introduction... 3 2. Service... 3 3. Warranty... 3 4. Application range... 4 5. Main technical parameters... 4 6. Performance index... 5 Vibration

More information

INSTRUCTION MANUAL EPH-121 CONTENTS

INSTRUCTION MANUAL EPH-121 CONTENTS INSTRUCTION MANUAL EPH-121 CONTENTS SAFETY PRECAUTIONS 1 NAME OF COMPONENT PARTS 5 HOW TO ASSEMBLE THE FRAME 6 OPEN AND CLOSE THE PANELS 7 OPERATION 9 TIMER OPERATION 10 SHUTDOWN 11 ROUTINE MAINTENANCE

More information

ZP04 Flammable Gas Detection Module (Model:ZP04) Manual V1.1. Zhengzhou Winsen Electronics Technology Co., Ltd

ZP04 Flammable Gas Detection Module (Model:ZP04) Manual V1.1. Zhengzhou Winsen Electronics Technology Co., Ltd ZP04 Flammable Gas Detection Module (Model:ZP04) Manual V. Zhengzhou Winsen Electronics Technology Co., Ltd Statement This manual s copyright belongs to Zhengzhou Winsen Electronics Technology Co., LTD.

More information

E1000 Portable gas detector

E1000 Portable gas detector E1000 Portable gas detector Operation manual Ver:HWWM161229CG Read this manual carefully before using the device Table of Contents SAFETY INFORMATION... - 1-1. BRIEF INTRODUCTION... - 3-2. MAIN FUNCTION

More information

DSD-080 SEISMIC SECURITY PANEL DESCRIPTION FEATURES. DSD-080 User Manual

DSD-080 SEISMIC SECURITY PANEL DESCRIPTION FEATURES. DSD-080 User Manual DSD-080 SEISMIC SECURITY PANEL DESCRIPTION DATAKOM DSD-080 Seismic Security Panel monitors seismic motions of a strong earthquake and provides relay output signals from it. Output signals are used to shut-off

More information

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M PHOTOELECTRIC SENSORS EFA/B_-F Special family with inverted output logic Fully compatible with previous EF family Simple installation due to compact format Wide variety of models Ordering Information EFA/B

More information

ET10 Series Stand-alone LCD Fan Coil Thermostat

ET10 Series Stand-alone LCD Fan Coil Thermostat ET10 Series Stand-alone LCD Fan Coil Thermostat Features Modern Appearance Stylish Rotary dial and buttons Large LCD with backlight Separate power supply unit with high performance relay outputs Retention

More information

Ultrasonic Reflective Sensor

Ultrasonic Reflective Sensor Ultrasonic Reflective with an Adjustable Sensing Distance of 0.3 to 3 m Under Stable Operation without Background Interference Ensures a stable operating range with minimal side-lobe areas. Built-in unstable

More information

DLC Instruction Manual. Light Curing Machine MODEL. Table of Contents

DLC Instruction Manual. Light Curing Machine MODEL. Table of Contents Light Curing Machine Table of Contents Precautions for Electrical >>>>>>>>>>> 1 Equipment in Use Precautions >>>>>>>>>>>>>>>>>>>> 2 Recommended Procedure when >>>>> 4 Opening Product Packaging Part Names

More information

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

High Reliability Of Fiber Optic Amplifier For Convenient Mounting Fiber Optic Amplifier Reliability Of Fiber Optic Amplifier For Convenient Mounting Features speed response: Max. 0.5ms Auto sensitivity setting (Button setting)/remote sensitivity setting External synchronization

More information

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use! Mess-, Regel- und Überwachungsgeräte für Haustechnik, Industrie und Umweltschutz Lindenstraße 20 74363 Güglingen Telefon +49 7135-102-0 Service +49 7135-102-211 Telefax +49 7135-102-147 info@afriso.de

More information

7EF/7HF/7EC/7ES Temperature Controllers

7EF/7HF/7EC/7ES Temperature Controllers 7EF/7HF/7E/7ES Temperature ontrollers Dual 4 Digit LED Display Universal Input (6 T/, RTD, mv, V, ma) Autotuning NEMA 4X 100 to 240 Vac Switching Power Supply Algorithms for Heat or Heat/ool ontrol 2 Independent

More information

Ceiling Mount Temperature Sensor

Ceiling Mount Temperature Sensor AB-5272 Specifications/Instructions Ceiling Mount Temperature Sensor General Ceiling Mount Temperature Sensor Model TY7301 is a temperature sensor designed to be used with electronic controllers. This

More information

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03 Digital Controller A 96 x 96-mm (DIN) Digital Process Controller Optimum PID control with feed-forward control circuitry. High accuracy (+0.3% FS +1 digit max.). Replaceable Output Units. Models with communications

More information

Digital Heater Element Burnout Detector K8AC-H

Digital Heater Element Burnout Detector K8AC-H Digital Heater Element Burnout Detector K8AC-H A high-precision Heater Element Burnout Detector compatible with a wide-range of heater control methods. Push-in terminals reduce the workload. *1 Scaling

More information

High sound volume buzzer

High sound volume buzzer High sound volume buzzer SBS-55L High sound volume unit SBS-55L is a device which detects shock and tilt and emit high sound volume of 110dB. Moreover, it is waterproof, small as a cigarette package and

More information

Forced Convection Constant Temperature Oven. Instruction Manual

Forced Convection Constant Temperature Oven. Instruction Manual Forced Convection Constant Temperature Oven Model DNE 400/40/600 60/80/90 Instruction Manual - Version 7 - Thank you for purchasing "Forced Convection Constant Temperature Oven, DNE Series" of Yamato Scientific

More information

WARM LINE. IV Fluid Warmer. Product Code: J1448. JORGENSEN LABORATORIES PHONE FAX

WARM LINE. IV Fluid Warmer. Product Code: J1448. JORGENSEN LABORATORIES PHONE FAX WARM LINE IV Fluid Warmer Product Code: J1448 JORGENSEN LABORATORIES PHONE 800-525-5614 FAX 970-663-5042 info@jorvet.com Warm Line IV Fluid Warmer Portable and light weight Only warms IV fluids not transfusion

More information

QUICK 3202 OPERATION MANUAL. Lead Free Soldering Station

QUICK 3202 OPERATION MANUAL. Lead Free Soldering Station QUICK 30 Lead Free Soldering Station OPERATION MANUAL Thank you for purchasing the unit. It is designed for lead free soldering. Please read this manual carefully before use and keep it for future reference.

More information

Part 3 Troubleshooting

Part 3 Troubleshooting Part Troubleshooting What is in this part? This part contains the following chapters: Chapter See page Troubleshooting 2 Error Codes: Hydro-box 7 Error Codes: Outdoor Units Error Codes: System Malfunctions

More information

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS CONTENTS 1. INTRODUCTION... 5 2. WARNINGS... 6 3. GENERAL DESCRIPTION... 7 4. INSTALLATION... 8 5. LUMINOUS INDICATORS AND COMMANDS... 9 6. DIP-SWITCH

More information

Ultrasonic Reflective Sensor

Ultrasonic Reflective Sensor Ultrasonic Reflective with an Adjustable Sensing Distance of 0.3 to 3 m Under Stable Operation without Background Interference Ensures a stable operating range with minimal side-lobe areas. Built-in unstable

More information

Scale 0: 10 k Scale 50: 10 k (see note 2)

Scale 0: 10 k Scale 50: 10 k (see note 2) Water Leak Alarm/Detector Eliminate Problems Caused from Water Leakage 0 to 50 k variable operating resistance to detect virtually any liquid. Two types available: Water Leak Alarm (61F-WLA) and plug-in

More information

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Universal controller for panel mounting Models CS6S, CS6H, CS6L Accessories Universal controller for panel mounting Models CS6S, CS6H, CS6L WIKA data sheet AC 85.08 Applications Plant and industrial furnace construction Process engineering Plastics technology and processing

More information

Installation Instructions

Installation Instructions 0908HN50 Lossnay Energy Recovery Ventilator Model: LGH-50RSDC-E (0-0V 50Hz) Installation Instructions (For use by dealer/contractor) Contents Safety precautions... Outline drawings... Standard installation

More information

PDA20DX Air Purifying Dehumdifier Manual

PDA20DX Air Purifying Dehumdifier Manual PDA20DX Air Purifying Dehumdifier Manual Index Important Safe Guards Ambient Environment For Operating Components Diagrams---Parts Names Operating Introduction---How to operate - Functions of Control Panel

More information

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F Temperature Controller 1/16 DIN Sized Controller Offers Selectable Control, Alarm Modes Accurate to ±0.5% of full scale Multiple temperature scale ranges allow flexibility to match application Field-selectable

More information

Original instructions. Operation Manual & Cautions

Original instructions. Operation Manual & Cautions Original instructions Operation Manual & Cautions Thank you for purchasing the Mistresa from Showa Denki. This manual explains the specifications for the [Mistresa units from CRN Series]. Please read the

More information

Safety. Operating instructions UV sensor UVS 5 DANGER. Contents WARNING CAUTION Elster GmbH Edition Please read and keep in a safe place

Safety. Operating instructions UV sensor UVS 5 DANGER. Contents WARNING CAUTION Elster GmbH Edition Please read and keep in a safe place 06 Elster GmbH Edition 0.6 Translation from the German 0556 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions UV sensor UVS 5 Cert. version 0.6 Contents UV sensor UVS 5... Contents...

More information

Buzzer Unit. TAN-5000 Series. Operating Manual

Buzzer Unit. TAN-5000 Series. Operating Manual PT1E-1040 Buzzer Unit TAN-5000 Series Operating Manual Request for the Customers Read and understand this operating manual before using the buzzer unit. Use the buzzer unit in accordance with the operating

More information

Pressure Switches Precautions 1 Be sure to read this before handling.

Pressure Switches Precautions 1 Be sure to read this before handling. Pressure Switches Precautions 1 Design / Selection 1. Confirm the specifications. Products represented in this catalog are designed ony for use in compressed air systems (including vacuum). Do not operate

More information

No.THD51E To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual.

No.THD51E To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual. Instruction manual Hygrothermo transmitter THD-500 Series No.THD51E1 2001.11 To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual. Notes This

More information

Chapter 5 Inspection and maintenance

Chapter 5 Inspection and maintenance Basic guide Chapter 5 Inspection and maintenance Bench-top type temperature (and humidity) chamber Chapter 5 Inspection and maintenance This chapter describes how to perform regular inspection and maintenance

More information

General Specifications

General Specifications General Specifications GS J0H-0E Model MVHK Digital Limit Alarm (DC Type) with Active Color PV Display General This plug-in type Digital Limit Alarm for DC input receives DC current or DC voltage signal.

More information

DNC-PS700-A10 Differential Pressure Control Meter. Operation and Installation Manual

DNC-PS700-A10 Differential Pressure Control Meter. Operation and Installation Manual DNC-PS700-A10 Differential Pressure Control Meter Operation and Installation Manual NationalControlsCorp. Phone 800-323-2593 Fax 630-231-1377 www.nationalcontrols.com MII-PS700-011 N ationalc o ntro ls

More information

TILT SENSOR SWITCH. Item No. RBS Description Ball-Contact Version 13 Page 1 of 7 Publish Date May 29, 2018

TILT SENSOR SWITCH. Item No. RBS Description Ball-Contact Version 13 Page 1 of 7 Publish Date May 29, 2018 Page 1 of 7 Publish Date May 29, 2018 FUNCTION Rotation detection at 45 in vertical position APPLICATIONS 1 Rotation Detection for kinds of monitor/device 2 Toys / Entertainment devices FEATURES 1 Suitable

More information

OH720, OP720, HI720, HI722

OH720, OP720, HI720, HI722 Cerberus PRO OH720, OP720, HI720, HI722 Automatic fire detectors For the automatically addressable detector bus C-NET The ideal fire detector for every application Signal processing with detection algorithms

More information

for relative humidity and temperature

for relative humidity and temperature 1 861 1861P01 Duct sensor for relative humidity and temperature QFM65 Operating voltage AC 24 V Signal output DC 0...10 V for relative humidity and temperature Measurement accuracy ±3 % r. h. within the

More information

Hygro/hygrothermal transducers (hygrometric)

Hygro/hygrothermal transducers (hygrometric) Data Sheet 90.7031 Page 1/7 Hygro/hygrothermal transducers (hygrometric) for measuring relative humidity and temperature for mounting indoors, outdoors, and in air ducts with resistance, current or voltage

More information

Far-infrared Oil Heater Owner's manual

Far-infrared Oil Heater Owner's manual 16 Appearance and/or specifications of product can be changed for better quality and preference without prior notice ar-infrared Oil Heater Owner's manual 1 URRENT TEMP EMPTY UEL TARGET TEMP ALARM Heating

More information

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual MODEL: SP12C7 (Portable 4 gas detector) Operating Manual Guarantee and Repair Senko Co., Ltd. guarantees the products of SP series for 24 months from the shipping date and repairs or replaces the defected

More information

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFH24F3XYZ2 Stand-alone with Internal Humidity Sensor

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFH24F3XYZ2 Stand-alone with Internal Humidity Sensor Model TFH24FXYZ2 Stand-alone with Internal Humidity Sensor Description The TFH24FXYZ2 is a fully configurable controller designed specifically for 2 pipe and 4 pipe fan coil applications. No additional

More information

2-Wire Gas Detector Head GD-K88Ai Operating Manual (PT2-193)

2-Wire Gas Detector Head GD-K88Ai Operating Manual (PT2-193) PT2E-1931 2-Wire Gas Detector Head GD-K88Ai Operating Manual (PT2-193) 1. Outline of the Product... 3 1-1. Preface... 3 1-2. Purpose of use... 3 1-3. Definition of DANGER, WARNING, CAUTION,

More information

ML520G55 FEATURES. Package: φ5.6mm TO-CAN PKG APPLICATION. Reverse voltage

ML520G55 FEATURES. Package: φ5.6mm TO-CAN PKG APPLICATION. Reverse voltage TYPE NAME DESCRIPTION Mitsubishi ML5xx55 is a high-power, high-efficient semiconductor laser diode which provides emission wavelength of 638 nm and standard light output of 150mW. This LD has narrow-stripe

More information

BC-R10 Series. Burner Controllers

BC-R10 Series. Burner Controllers No. CP-SS-1885E BC-R10 Series Burner Controllers Summary BC-R10 Series burner controllers are combustion safety controllers specifically designed for batch operation (systems which start and stop at least

More information

LC1350 Level Controller

LC1350 Level Controller LC1350 Controller Description The Spirax Sarco LC1350 has two alarm channels that can be independently configured high or low to control the water level of a boiler, tank or vessel by operating a pump,

More information

iworx Air Side Application Wiring Guide

iworx Air Side Application Wiring Guide iworx Side Application Wiring uide Pages ASM2 Sequence of peration & ypical Wiring 1 ALM2 Sequence of peration & ypical Wiring 2 U2 Sequence of peration, Flow iagram & ypical Wiring 3 - U3 Sequence of

More information

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. INSTRUCTION MANUAL MICRO-COMPUTER BASED DIGITAL INDICATOR JIR-31-M No.JIR31E3 24.7 To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. SAFETY

More information

E3M-V. Mark Sensor. Applications

E3M-V. Mark Sensor. Applications Mark Sensor Detects laminated or light-dispersing objects in stable operation without being influenced by mirror reflection. Double indication of the detection level and threshold level allows easy grasp

More information

Instruction manual Temperature Controller KT7

Instruction manual Temperature Controller KT7 Instruction manual Temperature Controller KT7 No. KT71E7 201.05 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. SAFETY PRECAUTIS Be sure

More information

Parts introduction FRONT BACK

Parts introduction FRONT BACK Lando Industrial Water Chillers installation instructions Thank you for using the machine from Shenzhen Lando Technology Industrial Co.,Ltd.. Please read the installation instructions carefully before

More information

Instruction Manual EVA-S6 Base

Instruction Manual EVA-S6 Base Instruction Manual EVA-S6 Base Sounder Base NITTAN COMPANY, LIMITED 1-54-5 SASAZUKA, SHIBUYA-KU, TOKYO 151-8535, JAPAN http://www.nittan.com Before Installation Please read these instructions carefully

More information

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE Cat. N STOP & GO automatic resetting 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat. N (s) : 4 062 88 / 4 062 89 CONTENTS PAGE 1. Description - Use... 1 2. Product

More information

Series Temperature Controller Instruction Sheet

Series Temperature Controller Instruction Sheet Series Temperature Controller Instruction Sheet Thank you very much for purchasing DELTA A Series. Please read this instruction sheet before using your A series to ensure proper operation and please keep

More information

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual MODEL: SP12C7 (Portable 4 gas detector) Operating Manual Guarantee and Repair Senko Co., Ltd. guarantees the products of SP series for 24 months from the shipping date and repairs or replaces the defected

More information

FOCAS ppm Bilge Alarm. Product Specifications Rev.1.03 (T)

FOCAS ppm Bilge Alarm. Product Specifications Rev.1.03 (T) FOCAS-000 15ppm Bilge Alarm Product Specifications 01-06 Rev.1.03 (T) Alteration / correction hysteretic Date Revision The reason for revision / correction Approved Name 1 01-01-18 Rev.1.01 Internal Arrangement

More information

DIGITAL INDICATOR DI25

DIGITAL INDICATOR DI25 DIGITAL INDICATOR DI25 Operating instructions Preface Thank you for purchasing our digital indicator DI25. This manual contains instructions for the mounting, functions, operations and notes when operating

More information

2-wire Passive Intelligent Loop (LED) Display Meter

2-wire Passive Intelligent Loop (LED) Display Meter Features Two-wire passive intelligent loop current (LED) digital meter 2-wire Passive Intelligent Loop (LED) Display Meter Embedded 2-wire Passive Programmable 4-20mA Loop (Four Digits LED) Display Meter

More information

FULL AUTOMATIC EXTINGUISHING SYSTEM FOR INDUSTRIAL MACHINERY YAC-3A. Table of Contents

FULL AUTOMATIC EXTINGUISHING SYSTEM FOR INDUSTRIAL MACHINERY YAC-3A. Table of Contents INSTRUCTION MANUAL FULL AUTOMATIC EXTINGUISHING SYSTEM FOR INDUSTRIAL MACHINERY YAC-3A Table of Contents Checking the package contents Before using this product. Structural diagram 2. Installation work

More information

ML562G84 APPLICATION. Display system. Symbol Parameter Conditions Ratings Unit. Pulse (Duty 40%)

ML562G84 APPLICATION. Display system. Symbol Parameter Conditions Ratings Unit. Pulse (Duty 40%) TYPE NAME DESCRIPTION Mitsubishi is a high-power, highly efficient semiconductor laser diode which provides emission wavelength of 638 nm and standard light output of 2.5W (pulse). This LD has broad-stripe

More information

Annuciator Logic Controllers

Annuciator Logic Controllers C B0 C C5 C C6 C C7 A B A B A B A B A5 B5 A6 B6 A7 B7 A8 B8 A9 B9 5 Annuciator Logic Controllers 68 c5 c6 c7 B B B B B5 B6 B7 B8 B9 B0 B B B B B5 B6 C0 BUZZER RETURN BZ M / BZ CTROL SIGNAL LAMP DC() DC()

More information

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER MODEL AH3 7 P - - A AH3000 series conforming to CE, UL and CSA are 180mm pen type hybrid recorders with a simultaneous display of multi-channel data,

More information

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes 50-120 1 General The heat exchanger control system is a control system for 380 W step motors

More information

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death. Please Read: Safety Precautions DC AC In order to ensure that this product is used safely, be sure that you read and understand the following precautions fully and use the product only as directed. Be

More information