USER MANUAL. Content. XD W/250W Medical Cold Light source. ⅠBrief introduction...1

Size: px
Start display at page:

Download "USER MANUAL. Content. XD W/250W Medical Cold Light source. ⅠBrief introduction...1"

Transcription

1 Content ⅠBrief introduction...1 XD W/250W Medical Cold Light source USER MANUAL II. Performance Summarize...1 III Main technical parameters...1 IV Security tips and symbols...2 V Working Environment...2 VI Product listⅦ. Product interface...2 Ⅷ Operating instructions...3 Ⅸ Failure Judgment and Eliminating Methods...3 Ⅹ Note and instructions...3 Ⅺ Replacement of bulbs...4 ⅩⅢAfter-sales service warranty...5 Ⅻ Transportation and storage conditions...5 Ⅹ Ⅳ Electrical schematic diagram and components list...6

2 Ⅰ.Brief introduction XD W/250W medical cold light source, as the supporting of light source and other equipment, is used for deep lighting like clinical examination, operation treatment etc. II. Performance Summarize 1.The cold light source adapts to wide range voltage. Both the output voltage and the bulb intensity of illumination, color temperature keep constant stable when the network voltage in 198 V-242 V fluctuation change. There is no need to use a voltage stabilizer and extend the life of the bulb. 2. Brightness adjusting linear is excellent from strong to weak. 3. The light source is strong in anti-interference. It will neither interfere other equipment nor be interfered by other equipment. It overcomes the defect that the silicon controlled circuit is easily influenced by net electricity and other sensitive equipments. 4. The design and production of this light source strictly executes the first part of the safety requirements of medical electrical equipment GB : general requirements which is guaranteed in safety. III Main technical parameters 1. Input voltage: AC 110V/220V 50Hz-60HZ 2. Halogen bulb: 24V/150W 24V/250W 3. Input power of 150W: 220W 4. Input power of 250W: 400W 5. Illumination of 250W light source: LX 6. Illumination of 150W light source: LX 7. Color temperature: 3600k±500k 8. Fuse protector: 3A- 5 IV Security tips and symbols 1. In order to reduce fire, electric shock or personnel risk of injury, we should always obey the basic safety precautions in use. 1 Please read the instructions carefully and operate it in accordance with manual operation. 2 When replace the bulbs, you must first turn off the power switch of the light source and pull out the power cord. 3 Replacement of the fuse protector should be the same with the requirements of the following mark. 4 The light source mustn t be used directly for eyes. 2. The introduction of the following symbols Attention! Check the random documents Protect the grounding Disconnect the power V Working Environment A. Environmental temperature: -10 ~+40 B. Relative humidity : 75% C. The atmosphere: 86.0~106.0kPa VI Product list Main engine of light source: one Power line: one Connect the power

3 Ⅶ. Product interface XD W/250W 1. Power switch 2. Output brightness adjusting knob 3. The optical fiber interface of light output 4. Option switch Ⅷ Operating instructions 1. Confirm the power supply to have a good grounding attachment. 2. Open the power switch (1) and the light source begins to work. 3. Adjusting knob (2) can control the output size of light source. 4. (3) is the light output hole and is also the connection of optical fiber. Double orifice light source should be connected with the bulb. Ⅸ Failure Judgment and Eliminating Methods (It should be operated by the professionals) Fault phenomena Fault cause Solution Turn on the power switch, the indicator is not bright, fan does not turn, the lamp is not bright. Power lines have no electricity The power cord is not connected well Fuse damage Connect to the circuit where there is electricity supply Reconnect the power cord Change the fuse Turn on the power Brightness adjusting Transfer the switch, the indicator is button (3) is not open brightness adjusting bright and the fan button to the works well, but the maximum lamp is not bright. Bulb damage Change the bulb System line fault Contact with the after-sale service department for solution Other fault Contact with the after-sale service department for solution Ⅹ Note and instructions 1. The cold light source should be placed on a stationary area with aeration during operation. The distance between the fan hole on the back of the case and the back shelter should be 15cm. 2. Patients are not allowed to touch the cold light source during operation. 3. You are forbidden to look at the optical cable end or light outlet directly with your eyes to avoid damage to them after the cold light source is switched on. 4. Do not put other articles on the machine during operation. 5. The cold light source shouldn t be violently vibrated. Move it gently. 6. The cold light source should be placed on a dry area with aeration and covered by shields. 7. The cold light source should be sterilized with an UV sterilizing lamp regularly. 8. There is high voltage circuit in the machine, non-professional

4 personnel shall not open the box. Ⅺ Replacement of bulbs 1. When replace the bulb, you should choose the same model halogen bulbs. 2. Turn off the power switch and pull out the power cord. 3. 1Loose the screw of the bottom,open the cover,cover,bulb and bulb holder,remove the cover, 2Pull out the base of bulb, 3Pull out the damaged bulb from the lamp holder, install the new bulb and screw down the screws. Show as the following picture. wetting, etc. is not within the scope of warranty. Once receiving the goods, please sign and accept it after opening the package to inspect and confirm whether the instrument is crushed, scratched or not. Make sure there is no special unnumbered inside. If the goods are damaged and you did not inspect before sign it, It will be at your own risk. ⅩⅣElectrical schematic diagram and components list Ⅻ Transportation and storage conditions Environmental temperature: -40 ~55 Relative humidity : 70% The atmosphere: 50Kpa~106Kpa ⅩⅢAfter-sales service warranty Warranty of 18 months, provide maintenance service all user s life. In the warranty period, in normally using, the trouble because of the product quality, the consumer depends on the warranty slip and invoice enjoys free maintenance service. If the error caused by remodel or install other functions which is without our company s permission, is not within the scope of warranty. If the model, number, release date is modified, deleted, moved or illegibility, will not enjoy the maintenance service. The error caused by human factor such as falling, squeezing, dip in, N0. Material name Specification Quantity Remark 1 Circuit board 7D1A 1 2 Field-effect tube SL20C20U 1 3 Filter choke 220mH 1 4 Inductance 470mH 1 5 Capacitance F103M/2KV 3 6 Capacitance 22nj/T100V 1 7 Capacitance 102M/2KV 1 8 Electrolytic capacitor 50V/1uf 1 9 Capacitance 222J/250V 1

5 10 Capacitance 102J/100P 1 11 Electrolytic capacitor 50V/4.7uf 3 12 Electrolytic capacitor 50V/22uf 1 13 Electrolytic capacitor 50V/47uf 1 14 Electrolytic capacitor 50V/1000uf 2 15 Electrolytic capacitor 250V/470uf 2 16 CBB capacitor 400V/105J 1 17 Filter capacitor 0.1uf 2 18 Resistance 150K/0.25W 1 19 Resistance 15Ω /0.25W 2 20 Resistance 120KΩ /0.25W 1 21 Resistance 12KΩ /0.25W 1 22 Resistance 10KΩ /0.25W 1 23 Resistance 1KΩ /0.25W 1 24 Resistance 22KΩ /0.25W 1 25 Resistance 15KΩ /0.25W 1 26 Resistance 5.6KΩ /0.25W 2 27 Resistance 560Ω /0.25W 1 28 Resistance 1.2KΩ /0.25W 1 29 Resistance 3.9KΩ /0.25W 1 30 Resistance 680KΩ /0.25W 1 31 Resistance 1.5KΩ /0.25W 1 32 Resistance 100KΩ /0.25W 1 33 Resistance 4.7KΩ /0.25W 1 34 Resistance 220Ω /0.25W 1 35 Resistance 150KΩ /0.25W 5 36 Resistance 2Ω /0.25W 2 37 Resistance 22K/0.25W 2 38 Resistance 24Ω /0.25W 2 39 Resistance 3.9K/0.25W 2 40 Resistance 100Ω /3W 1 41 Resistance 680Ω /3W 1 42 Diode F Diode IN Diode IN Audion Thermistor 5D Piezoresistor 10D471K 1 48 Integrated circuit LM Rectifier bridge KBU Halogen lamp 150VA/250VA 2 51 Fan Φ Power socket 1 53 Power line 1 54 Fuse block 2 55 Power switch 1 56 Sticker 1 57 Scutcheon 1 58 Case 1 Any products may be updated or improved. The change of circuit or element specifications of the product will not with prior notice edition

6 Warranty card Company name: Address Product name Serial Number Sale date Fault description: Model Manufacture date Phone No. Remark: The warranty of our products is 18 months since the release date. (Please truthfully fill in this form, cut it according to the dotted line and send it back to our company, thank you for your cooperation) Maintenance card Company name: Address Product name Serial Number Sale date Fault description: Model Manufacture date Phone No. Remark: You can enjoy seventy percent discount for the maintenance services even if you use this card over the quality assurance period.

FagronLab NP-1 UV. Negative pressure workbench. User Manual

FagronLab NP-1 UV. Negative pressure workbench. User Manual Negative pressure workbench User Manual Table of contents 1. Introduction... 3 2. Service... 3 3. Warranty... 3 4. Application range... 4 5. Main technical parameters... 4 6. Performance index... 5 Vibration

More information

QUICK 3202 OPERATION MANUAL. Lead Free Soldering Station

QUICK 3202 OPERATION MANUAL. Lead Free Soldering Station QUICK 30 Lead Free Soldering Station OPERATION MANUAL Thank you for purchasing the unit. It is designed for lead free soldering. Please read this manual carefully before use and keep it for future reference.

More information

SoleFish Pool Robot. INSTRUCTION MANUAL Note: Subject to update by manufactrer without notice in advance

SoleFish Pool Robot. INSTRUCTION MANUAL Note: Subject to update by manufactrer without notice in advance SoleFish Pool Robot INSTRUCTION MANUAL Note: Subject to update by manufactrer without notice in advance Important Precautions 1. In order to prevent severe damage to the cleaner, never power on the unit

More information

Electronic Analytical Balance Model DWP-B2004 USER MANUAL

Electronic Analytical Balance Model DWP-B2004 USER MANUAL Electronic Analytical Balance Model DWP-B2004 USER MANUAL INDEX Ⅰ Summary------------------------------1 Ⅱ Setting------------------------------2 Ⅲ Using--------------------------------6 Ⅳ Choose sensitive

More information

Operating Manual MS220DA

Operating Manual MS220DA ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße 13, D 74523 Schwäbisch Hall + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA Mains Monitoring Digital Panel Meters MINIPAN

More information

CRISTAL Built-in Dish Sterilizer Instruction Manual

CRISTAL Built-in Dish Sterilizer Instruction Manual CRISTAL Built-in Dish Sterilizer Instruction Manual Model No.: D36DSS Version Number: 01 Revision Date: September 2014 Dear user: Thank you for your purchase of CRISTAL built-in dish sterilizer! Please

More information

Skymen Cleaning Equipment Shenzhen Co., Ltd. Ultrasonic Cleaner Instruction Manual

Skymen Cleaning Equipment Shenzhen Co., Ltd. Ultrasonic Cleaner Instruction Manual Skymen Cleaning Equipment Shenzhen Co., Ltd. Ultrasonic Cleaner Instruction Manual Model: JP-360ST and JP-300ST Please read the manual carefully before operation. 1 INDEX 1. Working conditions. 3 2. General..

More information

Instructions. Portable Absorb Phlegm. Apparatus

Instructions. Portable Absorb Phlegm. Apparatus Instructions On Portable Absorb Phlegm Apparatus Please carefully read the instructions before attempting to operate this apparatus. Product Features 1. General Portable absorb phlegm apparatus designed

More information

MST, INC. MODEL 2002 OXYGEN MONITOR (AMBIENT-TYPE) OWNER S MANUAL

MST, INC. MODEL 2002 OXYGEN MONITOR (AMBIENT-TYPE) OWNER S MANUAL MST, INC. MODEL 2002 OXYGEN MONITOR (AMBIENT-TYPE) OWNER S MANUAL IMPORTANT WARNING WHEN THE OXYGEN MONITOR IS CORRECTLY INSTALLED AND MAINTAINED, IT MONITORS THE LEVEL OF OXYGEN IN ITS SURROUNDINGS 07/11

More information

UL U TR LTRASONIC S ONIC SCALE ALER PIEZO MINI

UL U TR LTRASONIC S ONIC SCALE ALER PIEZO MINI ULTRASONIC SCALER PIEZO MINI CONTENTS XI - SYMBOLS 1. INTRODUCTION 1 Alternating current Type BF device 2. WARNINGS 1 3. PRESENTATION 1 3.1 Presentation 1 3.2 Technical description 2! Warning, please refer

More information

Swimming pool värmepump Heat Dragon

Swimming pool värmepump Heat Dragon Swimming pool värmepump Heat Dragon (THP05n~THP08n) INSTALLATIONS OCH ANVÄNDAR MANUAL Content I. Application 2 II. Features 2 III. T e c h n i c a l Parameters 3 IV. Dimension 4 V. I n s t a l l a t i

More information

Operating Manual MS220KA and MSR220KA

Operating Manual MS220KA and MSR220KA Temperature Relays and MINIKA, Mains Monitoring, Digital Panel meters MINIPAN, Switching Relays and Controls Operating Manual MS220KA and MSR220KA ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße

More information

INTERNATIONAL MACHIINE CONCEPTS. Operating Manual. Tablet Counting and Filling Machine. Model IMC

INTERNATIONAL MACHIINE CONCEPTS. Operating Manual. Tablet Counting and Filling Machine. Model IMC Operating Manual Tablet Counting and Filling Machine Model IMC-16-1 - CONTENTS 1. Precautions 2. Introduction to the machine 3. Relevant Technical Data 4. Working environment 5. Introduction to the control

More information

Goldpress 4+ OPERATING, MAINTENANCE AND SAFE USAGE MANUAL OF THE GOLDPRESS 4+ MACHINE

Goldpress 4+ OPERATING, MAINTENANCE AND SAFE USAGE MANUAL OF THE GOLDPRESS 4+ MACHINE Goldpress 4+ OPERATING, MAINTENANCE AND SAFE USAGE MANUAL OF THE GOLDPRESS 4+ MACHINE SAFETY INSTRUCTIONS: Before putting the machine into operation please read the safety precautions, manufacturer recommendations

More information

Wine Cooler. Instruction Manual PWC-24ZWX

Wine Cooler. Instruction Manual PWC-24ZWX Wine Cooler Instruction Manual PWC-24ZWX WINE COOLER MANUAL PWC-24ZWX PLEASE READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE USE. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN BODILY INJURY, AND/OR

More information

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN TTK 75 ECO EN OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN Table of contents Notes regarding the operating manual... 01 Information about the device... 02 Safety... 04 Transport...05 Start-up...05

More information

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) IRDH375_D00124_01_D_XXEN/07.2018 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Product

More information

650/1000 Antihalo 650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel. User manual. theatre spotlight

650/1000 Antihalo 650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel. User manual. theatre spotlight 650/1000 Antihalo 650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel User manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0

More information

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL IMPORTANT WARNING WHEN THE CO MONITOR IS CORRECTLY INSTALLED AND MAINTAINED, IT MONITORS THE LEVEL OF CARBON MONOXIDE IN ITS SURROUNDINGS..

More information

Intelligent Swing Gate Turnstile Operating Manual CPW-322CS

Intelligent Swing Gate Turnstile Operating Manual CPW-322CS Intelligent Swing Gate Turnstile Operating Manual CPW-322CS C O N T E N T S 1. General Descriptions...1 2. Definitions... 1 2.1 Swing Gate Turnstile... 1 2.2 Passing Modes... 2 3. Safety Precautions...3

More information

INSTRUCTION MANUAL. Model Number : CF-300K, CHEST FREEZER BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

INSTRUCTION MANUAL. Model Number : CF-300K, CHEST FREEZER BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS. INSTRUCTION MANUAL Model Number : CF-300K, CHEST FREEZER BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS. 1 CF-300K Dear customers, Thank you for purchasing our product.

More information

Watt-Muncher Load Bank Manual WATT-MUNCHER. Portable Load Bank. 6 June 2018 Simplex Service Page 1 of 13

Watt-Muncher Load Bank Manual WATT-MUNCHER. Portable Load Bank. 6 June 2018 Simplex Service Page 1 of 13 WATT-MUNCHER Portable Load Bank 6 June 2018 Simplex Service 800-637-8603 Page 1 of 13 This manual was last revised: 6 June 2018 For up-to-date information on this product or others, please contact Simplex

More information

T3/E3 Fiber Optic Line Drivers

T3/E3 Fiber Optic Line Drivers MT618A-ST-R3 January 2004 MT619A-ST-R2 MT620AE-R2 T3/E3 Fiber Optic Line Drivers CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical

More information

ASL T6 / T7 / T8 / T9 FLOOR GRINDING MACHINES MANUAL

ASL T6 / T7 / T8 / T9 FLOOR GRINDING MACHINES MANUAL ASL T6 / T7 / T8 / T9 FLOOR GRINDING MACHINES MANUAL 1 Contents Preface 3 1.1 Safety Guide 4 1.2 Precautions 4 Chapter II 5 Purchase Check, Technical Parameter and Product Description 5 2.1 Purchase Check

More information

Lead Free Soldering Pot I100-15S

Lead Free Soldering Pot I100-15S Lead Free Soldering Pot I100-15S INSTRUCTION MANUAL Thank you for purchasing the Lead Free Soldering Pot. Please read this manual before operating the unit. Store this manual in a safe, easily accessible

More information

Laser Distance Sensor Type M Analog-Output

Laser Distance Sensor Type M Analog-Output Laser Distance Sensor Type M Analog-Output Operating Manual Version 2.3, May 2009 ELAG Elektronik AG l Stegackerstrasse 14 l CH-8409 Winterthur Contents 1. Safety 1.1 Laser safety 1.2 Electrical safety

More information

SET Installation and Operating Instructions. Level switch for one sensor

SET Installation and Operating Instructions. Level switch for one sensor Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel.: +358 29 006 260 Fax: +358 29 006 1260 7.11.2013 Internet: www.labkotec.fi 1/14 SET-1000 Level switch for one sensor Copyright 2013 Labkotec Oy

More information

USERS MANUAL FOR GAS BOILERS

USERS MANUAL FOR GAS BOILERS USERS MANUAL FOR GAS BOILERS PLEASE READ THE MANUAL CAREFULLY: IT CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, INSTALLATION, USE AND MAINTENANCE OF THE APPLIANCE MODELS: NOVADENS 24 NOVADENS 24C NOVADENS

More information

Model KBWF 240 Growth chambers with light and humidity

Model KBWF 240 Growth chambers with light and humidity Model KBWF 240 Growth chambers with light and humidity The BINDER climate chamber with illumination of the KBW series achieves homogeneous light distribution with its natural illumination. That allows

More information

Products documentation (REVISION DATE: 03/10/2011) OMFP6010 (60cm PIROLITIC OVEN)

Products documentation (REVISION DATE: 03/10/2011) OMFP6010 (60cm PIROLITIC OVEN) Products documentation (REVISION DATE: 03/10/2011) OMFP6010 (60cm PIROLITIC OVEN) Ovens Service Manual Models OMFP6010 CONTENTS This document has been published to be used for service only. The contents

More information

EVAPORATIVE COOLER W

EVAPORATIVE COOLER W EVAPORATIVE COOLER 972-1003-W USER MANUAL INTRODUCTION READ AND SAVE THESE INSTRUTIONS! 1 Thanks for your support and choice of our unique tower fan, in order to help you use the product more conveniently,

More information

WINE COOLER INSTRUCTION MANUAL

WINE COOLER INSTRUCTION MANUAL CW-65DD WINE COOLER INSTRUCTION MANUAL PLEASE READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE USE. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN BODILY INJURY, AND/OR PROPERTY LOSS. RETAIN INSTRUCTION

More information

Model KBWF 720 Growth chambers with light and humidity

Model KBWF 720 Growth chambers with light and humidity Model KBWF 720 Growth chambers with light and humidity The BINDER climate chamber with illumination of the KBW series achieves homogeneous light distribution with its natural illumination. That allows

More information

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWS150B3V3 EKHWS200B3V3 EKHWS300B3V3 EKHWS200B3Z2 EKHWS300B3Z2

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWS150B3V3 EKHWS200B3V3 EKHWS300B3V3 EKHWS200B3Z2 EKHWS300B3Z2 INSTALLATION MANUAL Domestic hot water tank for air to water heat pump system EKHWS50BV EKHWS00BV EKHWS00BV EKHWS00BZ EKHWS00BZ 4 5 6 x x x 4x x + x 00 7 05 0 45 5 400 5 6 00 /4" FBSP 6 H 0 H4 H 0 H 0

More information

Electronic Emergency Telegraph. TG-1 and TG-1A

Electronic Emergency Telegraph. TG-1 and TG-1A Electronic Emergency Telegraph modification level Version Date Author Approved Remarks 01 23.10.2012 STO TK 1st issue Page: 1 TABLE OF CONTENTS 1. IMPORTANT SAFETY INSTRUCTIONS 3 1.1. QUALIFIED PERSONNEL

More information

STATIC ELIMINATOR I443A INSTRUCTION MANUAL

STATIC ELIMINATOR I443A INSTRUCTION MANUAL STATIC ELIMINATOR I443A INSTRUCTION MANUAL Thank you for purchasing a Static Eliminator. It is designed to eliminate the static charge from a charged object. Please read this manual before operating the

More information

RINGMASTER 5-1/2 & 7 COTTON CANDY MACHINE

RINGMASTER 5-1/2 & 7 COTTON CANDY MACHINE 3243 North California Avenue, Chicago, IL 60618 RINGMASTER 5-1/2 & 7 COTTON CANDY MACHINE 120 Volt, Single Phase, 50/60 Cycle 230 Volt, Single Phase, 50 Cycle READ and UNDERSTAND these operating, servicing,

More information

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. Models MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 Indoor unit service manual MSZ-DM VA Series (OBH750) CONTENTS 1. TECHNICAL CHANGES 2 2. PART NAMES

More information

Infrared Moisture Determination Balance FD-610. Operating Manual

Infrared Moisture Determination Balance FD-610. Operating Manual Infrared Moisture Determination Balance FD-610 Operating Manual Infrared Moisture Determination Balance Safety Notes Improper use of the infrared moisture tester in violation of the following safety notes

More information

LM40 Medium Intensity Aviation Obstruction Light

LM40 Medium Intensity Aviation Obstruction Light Products description and applicaiton LM40 Series type A aviation obstruction lights with ICAO certificate. Type A aviation obstruction light play a warning role in tall buildings to reduce aviation hazards,daytime

More information

HT-2 / 9600 Series Control Contents

HT-2 / 9600 Series Control Contents HT-2 / 9600 Series Control Contents Tools & Parts Tools Required Parts Required Error Messages 3 Flashing Dots Pressure or Flow Switch Not Activated Pressure or Flow Switch Activated Temperature Sensor

More information

TCW 2000 Ice liner refrigerator and freezer PIJ

TCW 2000 Ice liner refrigerator and freezer PIJ TCW 2000 Ice liner refrigerator and freezer OVER VIEW The unique rotomoulded Chest Freezer and inclined Refrigerator with two separate compartments and compressors worldwide Hold over time @ 32 C Hold

More information

User Manual. TN1500 Embedding Center. Read Prior to Operation! Always keep this manual near the unit! WP

User Manual. TN1500 Embedding Center. Read Prior to Operation! Always keep this manual near the unit! WP User Manual TN1500 Embedding Center Read Prior to Operation! Always keep this manual near the unit! WP46818 06.02.15 User Manual TN1500-Embedding Center 888.708.5233 Info@TannerScientific.com www.tannerscientific.com

More information

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN TTV 1500 / TTV 3000 EN OPERATING MANUAL CONVEYING FAN TRT-BA-TTV1500-3000-TC2016-26-004-EN Table of contents Notes regarding the operating manual... 2 You can download the current version of the operating

More information

LED Colour Flood 10W / 30W RGB LED floodlight. user manual

LED Colour Flood 10W / 30W RGB LED floodlight. user manual LED Colour Flood 10W / 30W RGB LED floodlight user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet:

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624 REVISED EDITION-A Models MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE

More information

OPERATION MANUAL WARNING TAIYO ELECTRIC IND.CO.,LTD. MODEL XPR-600 PREHEATER

OPERATION MANUAL WARNING TAIYO ELECTRIC IND.CO.,LTD. MODEL XPR-600 PREHEATER MODEL XPR-600 PREHEATER OPERATION MANUAL WARNING Before using the XPR-600 Preheater, read the Owner's Operation Manual. Failure to follow the safety precautions and instructions in this manual could result

More information

Instruction Manual. gray Mounted Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:

Instruction Manual. gray Mounted Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F: gray Instruction Manual for gray Mounted Detectors F: +41 44 633 13 68 2 / 12 gray Mounted Detectors: Instruction Manual CONTENT 1. SHORT USER GUIDE... 4 2. THERMAL INTEGRATION OF THE DETECTOR... 5 2.1.

More information

TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE:

TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE: TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE: 560955 CE Directive 2006/95/CEE British Standard EN 60335-1 (C 73800) 1 CONTENTS Page 1) INTRODUCTION 1.1) Description 3 1.2) Dimensions & connections

More information

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR OWNER S MANUAL

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR OWNER S MANUAL MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR OWNER S MANUAL IMPORTANT WARNING WHEN THE CO MONITOR IS CORRECTLY INSTALLED AND MAINTAINED, IT MONITORS THE LEVEL OF CARBON MONOXIDE IN THE RESPIRATORY AIR

More information

Inverter Swimming Pool Heat Pump

Inverter Swimming Pool Heat Pump P Inverter Swimming Pool Heat Pump Content I. Application... 2 II. Features... 2 III. Technical Parameter... 3 IV. Dimension... 4 V. Installation instruction... 5 VI. Operation instruction... 9 VII. Testing...

More information

WARM LINE. IV Fluid Warmer. Product Code: J1448. JORGENSEN LABORATORIES PHONE FAX

WARM LINE. IV Fluid Warmer. Product Code: J1448. JORGENSEN LABORATORIES PHONE FAX WARM LINE IV Fluid Warmer Product Code: J1448 JORGENSEN LABORATORIES PHONE 800-525-5614 FAX 970-663-5042 info@jorvet.com Warm Line IV Fluid Warmer Portable and light weight Only warms IV fluids not transfusion

More information

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions HZM-Series-Class I, Div 2 Battery Unit HZM-Series-Class I, Div 2 Battery Unit Instalation instructions IMPORTANT SAFEGUARDS 1 4 5 6 7 13 When using electrical equipment, basic safety precautions should

More information

SECTION INTERIOR LIGHTING

SECTION INTERIOR LIGHTING SECTION 26 51 00 INTERIOR LIGHTING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

INSTRUCTIONS MANUAL CONTROLS. Description Power Rating Remarks Steamer. Description Power Rating Remarks Control

INSTRUCTIONS MANUAL CONTROLS.   Description Power Rating Remarks Steamer. Description Power Rating Remarks Control Description Power Rating Remarks Control Rated Power 3 Phases Rated Voltage 3 Phases Rated Power Single Phase Rated Voltage Single Phase Frequency Switching capacity per phase Sauna temperature range Maximum

More information

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide Miniature Thermoelectric Cooler Controller MTCC-01 user's guide 1 Table of Contents 1. Warranty... 3 2. MTCC-01-xxx overview... 4 2.1. MTCC-01-xxx specification... 4 2.2. TE cooled detector temperature

More information

Electron Microscopy Sciences

Electron Microscopy Sciences Electron Microscopy Sciences INSTRUCTIONAL MANUAL CAT. 62420-Series Bacti-Cinerator IV Inoculating Loop and Needle Sterilizer P.O. Box 550 s1560 Industry Road s Hatfield PA 19440 1 Introduction The BACTI-CINERATOR

More information

Refrigerated Incubator Model and Operating Instructions

Refrigerated Incubator Model and Operating Instructions Refrigerated Incubator Model 165000 and 165000-2 Operating Instructions N2400379 - Rev. 1 08May2018 1 Contents 1. SAFETY...3 1.1. EMF INTERFERENCE...4 1. PRODUCT INFORMATION...5 1.1 INTRODUCTION...5 2.

More information

Table of Contents. English

Table of Contents. English OM-E0799E 000 English Thank you for purchasing VIVA ace Motor Kit. Please read this Operation Manual and the VIVA ace Basic Set Operation Manual carefully before use for operating instructions and care

More information

Instruction Manual. Please read this manual carefully before operating this unit.

Instruction Manual. Please read this manual carefully before operating this unit. Instruction Manual Please read this manual carefully before operating this unit. Contents Ⅰ. INTRODUCTION...1 Ⅱ. SAFETY NOTES...1 Ⅲ. PRECAUTIONS...2 Ⅳ. MAINTENANCE...3 Ⅴ. HOW DOES YOUR ATMOSPHERIC WATER

More information

Intelligent Lead Free Soldering Station OPERATION and MAINTENANCE MANUAL

Intelligent Lead Free Soldering Station OPERATION and MAINTENANCE MANUAL Intelligent Lead Free Soldering Station Sensor in front High frequency heating Digital Calibration Rapid recovery of temperature OPERATION and MAINTENANCE MANUAL Thank you for purchasing a lead free soldering

More information

BILTONG CABINET WARRANTY

BILTONG CABINET WARRANTY WARRANTY BILTONG CABINET The manufacturer guarantees that this unit is free from defect in materials and workmanship when it leaves the factory and undertakes to replace or repair the unit if it proves

More information

E-17 Flammable Gas Detection and Alarm System

E-17 Flammable Gas Detection and Alarm System Guideline No.E-17 (201705) E-17 Flammable Gas Detection and Alarm System Issued date: May 9, 2017 China Classification Society Foreword This Guideline is a part of CCS Rules, which contains technical requirements,

More information

- ibidi heating system - stage top incubator for life cell imaging

- ibidi heating system - stage top incubator for life cell imaging Instructions - ibidi heating system - stage top incubator for life cell imaging Please also see the Add-on: - gas incubation with active gas mixer - Instructions, - ibidi heating system - Page 1 of 15

More information

TABLE OF CONTENTS CHAPTER 5 SPECIAL OCCUPANCIES CHAPTER 1 GENERAL RULES... 19

TABLE OF CONTENTS CHAPTER 5 SPECIAL OCCUPANCIES CHAPTER 1 GENERAL RULES... 19 TABLE OF CONTENTS About This Textbook...xiii How to Use the National Electrical Code... 1 Article 90 Introduction to the National Electrical Code... 7 90.1 Purpose of the NEC... 7 90.2 Scope of the NEC...

More information

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

OilSET Installation and Operating Instructions. Oil Separator Alarm Device Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 18.11.2010 Internet: www.labkotec.fi 1/10 OilSET-1000 Oil Separator Alarm Device Copyright 2010 Labkotec

More information

Automatic Sublimation Transfer Machine Manual Model. No.: ASTM-40/48/64

Automatic Sublimation Transfer Machine Manual Model. No.: ASTM-40/48/64 Automatic Sublimation Transfer Machine Manual Model. No.: ASTM-40/48/64 MIC CONTENTS I. Assembly Drawing -----------------------------------------------------------------------------------2 II. Technical

More information

Part 3 Troubleshooting

Part 3 Troubleshooting Part Troubleshooting What is in this part? This part contains the following chapters: Chapter See page Troubleshooting 2 Error Codes: Hydro-box 7 Error Codes: Outdoor Units Error Codes: System Malfunctions

More information

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC Revision D: MUFZ-KJ25VE - E2, ER2, ET2, MUFZ- KJ35VE - E2, ER2, ET2 and MUFZ- KJ50VE - E2, ER2, ET2 have been added. Please void OBH667 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A.

More information

ELECTRICAL APPLIANCE SERVICEPERSON EXAMINATION 7 May 2016 QUESTION AND ANSWER BOOKLET

ELECTRICAL APPLIANCE SERVICEPERSON EXAMINATION 7 May 2016 QUESTION AND ANSWER BOOKLET Candidate Code No. EAS 1078 For Board Use Only Result Date Int Result Date Int ELECTRICAL APPLIANCE SERVICEPERSON EXAMINATION 7 May 2016 QUESTION AND ANSWER BOOKLET Time Allowed: 2 Hours INSTRUCTIONS READ

More information

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN AIRGOCLEAN 10 E EN OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN Table of contents Notes regarding the operating manual... 1 You can download the current version of the operating manual and

More information

Operating manual 1 SAFETY REGULATIONS AND INFORMATION. Original operating manual INDEX 2218 F/2TDH4P

Operating manual 1 SAFETY REGULATIONS AND INFORMATION. Original operating manual INDEX 2218 F/2TDH4P Operating manual 2218 F/2TDH4P 1 SAFETY REGULATIONS AND INFORMATION Read the operating manual carefully before commencing work at the product. Pay attention to the following warnings to avoid risk to persons

More information

Q1. The diagram shows the inside of a mains plug. Label the earth, live and neutral pins.

Q1. The diagram shows the inside of a mains plug. Label the earth, live and neutral pins. Q1. The diagram shows the inside of a mains plug. (a) Label the earth, live and neutral pins. (3) (b) Explain how the earth wire and the fuse protect a person from an electric shock when there is a short

More information

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S EN OPERATING MANUAL INFRARED HEATING PANEL TRT-BA-TIH300S-TIH400S-TIH500S-TIH700S-TIH900S-TIH1100S-TC-002-EN Table of contents Notes

More information

Optional Optional. Min 20W, max 100W. Only resistive load or dimmable (phase control compatible) light bulb. Dimmer optional

Optional Optional. Min 20W, max 100W. Only resistive load or dimmable (phase control compatible) light bulb. Dimmer optional Description Power Rating Remarks Control Rated Power 3 Phases Rated Voltage 3 Phases Rated Power Single Phase Rated Voltage Single Phase Frequency Switching capacity per phase Sauna temperature range Maximum

More information

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified OPERATIONS MANUAL Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS-1001 Certified Contents 1. Safety 3 2. Introduction 7 3. Package Contents 7 4. Specifications 7 5. Features 8 6.

More information

Technical documentation

Technical documentation Technical documentation AIR WATER HEATERS IN STEEL CASING S SERIES MODELS: REVENTON GROUP S1-3S REVENTON GROUP S2-3S REVENTON GROUP S3-3S REVENTON GROUP S4-3S ENG TECHNICAL DOCUMENTATION Table of contents

More information

Dentistry Operating lights

Dentistry Operating lights Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 9680 Third edition 2014-10-15 Dentistry Operating lights Médecine bucco-dentaire Appareils d éclairage Reference number ISO 9680:2014(E) ISO 2014

More information

Chapter 1 General...9 Article 100 Definitions...11 Article 100 Questions Article 110 Requirements for Electrical Installations...

Chapter 1 General...9 Article 100 Definitions...11 Article 100 Questions Article 110 Requirements for Electrical Installations... Article 90 Introduction...1 90.1 Purpose of the NEC...1 90.2 Scope of the NEC...2 90.3 Code Arrangement...4 90.4 Enforcement...5 90.5 Mandatory Requirements and Explanatory Material...6 90.6 Formal Interpretations...6

More information

Fire Control Panel FS4000

Fire Control Panel FS4000 Fire Control Panel FS4000 INSTRUCTION MANUAL Revision 4/02.11 Contents 1. Introduction... 4 2. Terminology... 4 3. Function... 5 4. Technical features... 5 4.1 Fire alarm lines... 5 4.2. Current thresholds

More information

SERVICE-MANUAL INDUCTION COOKER BASE-LINE/FAJITA HEATER SH/BA 3500 FH

SERVICE-MANUAL INDUCTION COOKER BASE-LINE/FAJITA HEATER SH/BA 3500 FH SERVICE-MANUAL INDUCTION COOKER BASE-LINE/FAJITA HEATER SH/BA 3500 FH -1- CONTENT 1 Safety...2 1.1 Description of danger signs...2 1.2 Qualification and training of personnel...2 1.3 Safety prescriptions

More information

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15 with coupling device AGH675-7 and AGH675-7MV15 Device combination for insulation monitoring in unearthed AC, AC/DC and DC power systems (IT systems) IRDH275BM-7_D00123_03_D_XXEN/01.2017 with coupling device

More information

WiseBath WSB Shaking Water Bath Operation Manual (Version 1.4.0)

WiseBath WSB Shaking Water Bath Operation Manual (Version 1.4.0) WiseBath WSB Shaking Water Bath Operation Manual (Version 1.4.0) written for Model WSB-18/-30/-45 Contents Page 1. Safety Instructions........ 3 2. Before Use...... 8 3. Introduction... 9 4. Package Contents...

More information

INSTRUCTIONS FOR USE

INSTRUCTIONS FOR USE -1- INSTRUCTIONS FOR USE INDUCTION COOKERS Base-Line Fajita Heater SH/BA 3500 FH -2- CONTENT 1 General remarks...3 1.1 Description of danger signs...3 1.2 Purpose of induction cookers...4 2 Description

More information

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63 Fire Extinguishing Control Panel FS5200Е INSTRUCTION MANUAL Revision 8/01.17 Instruction Manual Page 1 1. 2. 3. 4. 4.1. 4.2. 4.2.1. 4.2.2. 4.2.3. 4.2.4. 4.2.5. 4.2.6. 4.2.7. 4.2.8. 4.2.9. 4.2.10. 4.2.11.

More information

Soldering Station INSTRUCTION MANUAL

Soldering Station INSTRUCTION MANUAL 2 9 0 0 Soldering Station INSTRUCTION MANUAL Thank you for purchasing model 2900 Soldering station. Please read manual before using the unit. Keep manual in an accessible place for future reference. Manufacturer:

More information

650/1000 Antihalo 650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel. User manual. theatre spotlight

650/1000 Antihalo 650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel. User manual. theatre spotlight 650/1000 Antihalo 650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel User manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0

More information

ELECTRICAL INSTALLER THEORY EXAMINATION. 14 November 2015 QUESTION AND ANSWER BOOKLET

ELECTRICAL INSTALLER THEORY EXAMINATION. 14 November 2015 QUESTION AND ANSWER BOOKLET Candidate Code No. EIN 11 For Board Use Only Result Date Int Result Date Int ELECTRICAL INSTALLER THEORY EXAMINATION 14 November 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours INSTRUCTIONS

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL ECONOMY OVENS SMO1E SMO3E MODELS OBSOLETED AFTER MAY 31ST SMO1E-2, SMO3E-2, SMO5E, SOM5E-2 INSTALLATION AND OPERATION MANUAL Revised June 13, 2017 861659 Sheldon Manufacturing Inc. P.O. Box 627 Cornelius,

More information

Operating Instructions

Operating Instructions Round Tissue Bath VWR Catalog Number 80086-982 VWR Catalog Number 80086-984 Operating Instructions N2400238 Rev. 0 CONTENTS Page 1. Safety... 2 2. Product Information... 3 3. Assembly... 3 3.1 Unpacking...

More information

ANGELUS (Ver 2.03) Patient Monitoring System

ANGELUS (Ver 2.03) Patient Monitoring System ANGELUS (Ver 2.03) Patient Monitoring System CONTENT Contents of Manual 1 Meaning of Symbols used in this manual 2 Section 1. GENERAL 3 1.1 Introduction 4 1.2 Composition of unit 8 1.3 Panel Description

More information

ANTIBACTERIAL HAND VAC WITH UV LIGHT

ANTIBACTERIAL HAND VAC WITH UV LIGHT User manual ANTIBACTERIAL HAND VAC WITH UV LIGHT CVH5743M 02/12 HOME APPLIANCES 1) Press the lever down. 2) Insert the vacuum cleaner while holding the lever down. 3) Once the vacuum cleaner is inserted

More information

E S D REWORK SYSTEM 3 IN 1, I702 USER S GUIDE

E S D REWORK SYSTEM 3 IN 1, I702 USER S GUIDE E S D REWORK SYSTEM 3 IN 1, I702 USER S GUIDE Thank you for purchasing the Rework system. This manual describes the use and maintenance of the Rework system. Please read it before reading the manual, keep

More information

EST User Manual. (Please read this manual carefully before using)

EST User Manual. (Please read this manual carefully before using) EST-1000 Handheld Intelligent Toxic Gas Detector User Manual (Please read this manual carefully before using) ENVIRONMENTAL SENSOR TECHNOLOGY CO.INC. Contents I. Product Overview...1 II. Product Description...1

More information

APPENDIX 4. Thank you for choosing the Biomega BioClave steam sterilizer. HYDRAULIC DRAWING

APPENDIX 4. Thank you for choosing the Biomega BioClave steam sterilizer. HYDRAULIC DRAWING Thank you for choosing the Biomega BioClave steam sterilizer. Your steam sterilizer has been CE certified and designed with durability, reliability, and safety in mind. It is your responsibility to install

More information

Bacti-cinerator Sterilizer

Bacti-cinerator Sterilizer A Geno Technology, Inc. (USA) brand name Bacti-cinerator Sterilizer Cat. No. BT1701, BT1702 1-800-628-7730 1-314-991-6034 info@btlab.com Thanks for choosing BT Lab Bacti-cinerator Sterilizer. This operation

More information

Functional Performance Test

Functional Performance Test Fire Alarm Control Panel & Fire Alarm Annunciator Panel Notify all building occupants that testing will be conducted. Fire alarm contractor shall have personnel with 2-way radios at the fire alarm control

More information

INSTRUCTION MANUAL. Laboratory Equipment Pty Ltd Ph: Fax:

INSTRUCTION MANUAL. Laboratory Equipment Pty Ltd   Ph: Fax: INSTRUCTION MANUAL Laboratory Equipment Pty Ltd email: sales@labec.com.au Ph: 02 9560 2811 Fax: 02 9560 6131 www.labec.com.au 2014 Shaking Water Bath Instruction Manual Model : J-SWB19, J-SWB35, J-SWB60

More information

TTV 4500 / TTV 4500 HP / TTV 7000

TTV 4500 / TTV 4500 HP / TTV 7000 TTV 4500 / TTV 4500 HP / TTV 7000 EN OPERATING MANUAL AXIAL FAN TRT-BA-TTV4500-4500HP-7000-TC-003-EN Table of contents The current version of the operating manual can be found at: Notes regarding the operating

More information

Fire Control Panel FS5100

Fire Control Panel FS5100 Fire Control Panel FS5100 INSTRUCTION MANUAL Revision 6/02.11 Contents 1. Introduction... 5 2. Terminology... 5 3. Function... 7 4. Technical data... 7 4.1. Modules... 7 4.1.1. Type of modules... 7 4.1.2.

More information