1 Fire Suppression Systems Public Buildings Custodial Food Industry Transportation Power Generation

2 The Hydramist product range was created to address fast, safe and efficient water based fire suppression systems that present no risks to the environment or people. fire suppression systems Hydramist Introduction Hydramist is a high pressure watermist fire fighting system manufactured by Watermist Limited in the UK that is designed to suppress and extinguish fires in a wide range of applications. With many years combined experience in fire suppression and equipment manufacture the Hydramist product has quickly become a leading fire suppression system in the United Kingdom and Europe. At Hydramist Fire testing is an integral part of our product development. We have tested a wide variety of applications using recognised fire testing institutions such as Building Research Establishment (BRE). Hydramist actively supports and is working with regulatory authorities to establish relevant standards and codes of practice. The company has a quality based approach to all of its activities and is UKAS accredited to ISO9001:2008, Hydramist products are CE marked in accordance with European regulations. Hydramist products have been installed in commercial kitchens, factories, offices, banks, hotels, public buildings including prisons, courts and libraries. Get in touch with us today, contact: Hydramist Fison Way, Thetford, Norfolk IP24 1HT United Kingdom T: +44 (0) E: W: 02 T: +44 (0) Introduction

3 product application Product applications, system design and application advice The Hydramist product range has many applications, including the following: Commercial Kitchens, Industrial Fryers, Ovens and Food Processing Factories Prisons, Hotels, Guest Houses and Accommodation Blocks Archive Stores and Libraries Power Generation (Diesel Generators, Turbines, Battery Rooms) Specialists available to survey, design and specify fire suppression systems Hydramist design manual available to guide architects, consultants and equipment suppliers Telephone help line to provide advice and guidance on selection of nozzles and equipment Website interactive notice board to provide feedback and comments Engine Test Cells Data Centres, Communications and Server Rooms Plant and Electrical Switch Rooms Offices and Public Buildings Warehouses and General Storage Facilities W: Case Studies 03

4 fire suppression products (please note images are not to scale) MHRU Modular Hose Reels Fixed Hose Reel Cabinet Offering a more effective alternative to conventional hose reels, the Hydramist Modular Hose Reels flow less than a quarter of the water provided by a conventional hose reel and because the water is atomised it can protect an area up to 100 times larger. MHRU s are used extensively within the United Kingdom prison service for fighting fires in cells and accommodation areas and the food industry for effectively dealing with fires in waste bins and fryers. Installed as replacement or in addition to a conventional hose reel Can be installed anywhere in any building requiring only a 15mm water supply and single phase power supply Hose reach 35m 50m Easy to use trigger assembly and controls Reduced water use and residual water damage Dramatically reduces smoke spread from the fire Proven in extensive testing with the UK Building Research Establishment and the Ministry of Justice to provide a life sustainable environment whilst in use Patent GB Used in conjunction with the Hydramist range of fixed pump sets, the Fixed Hose Reel Cabinet gives a flexible method of providing high pressure watermist fire fighting into any building or area. Used extensively within the United Kingdom prison service for fighting fires in cells and accommodation areas the Hydramist Fixed Hose Reel Cabinet can be installed anywhere that a conventional hose reel is used. Fire fighting system that can be quickly deployed around any building Installed as replacement or addition to a conventional hose reel Can be installed anywhere in any building in conjunction with a Hydramist fixed pump set Hose reach 35m 50m Easy to use trigger assembly and controls Proven in extensive testing with the UK Building Research Establishment and the Ministry of Justice to provide a life sustainable environment whilst in use Reduced water use and residual water damage Dramatically reduces smoke spread from the fire 04 T: +44 (0) Product Range

5 fire suppression products (please note images are not to scale) 120PU Pump Sets CPU Pump Set Range With an output of 120 litres per minute at a constant pressure of 100bar the 120PU pump sets can be coupled together to give increased outputs of 240litres/min, 360litres/min (or any other multiple of 120litres/ min). Used primarily for larger risks, the Hydramist 120PU has been used to provide protection to IT Data Centres, Power Generation plants, Archive and Library storage areas, Food factory production lines and many other risks both large and small. Food factory production lines Power generation equipment Server and Communications rooms Local application risks with multiple areas Each 120PU delivered complete and tested Reduced water use and residual water damage Low power consumption and start up configuration Delivered complete with integral 1000 litre water tank Available with outputs of 30, 36, 45 & 54 litres per minute at a constant pressure of 100bar the CPU range was designed to be compact to enable easy installation into confined spaces within buildings. Used extensively within the UK prison service and food industry the CPU is most suited to multiple areas requiring protection. Food factory production lines Power generation equipment Server and Communications rooms Prisons (when used in conjunction with Fixed Hose Reel Cabinets or fixed in cell nozzles) Local application risks with multiple areas Each CPU delivered complete and tested Reduced water use and residual water damage Low power consumption Delivered complete with integral 250 litre water tank W: Product Range 05

6 fire suppression products (please note images are not to scale) Mobile 8 Nozzles Providing fast reactive fire fighting, the Hydramist Mobile 8 unit is used extensively, but not exclusively, within the United Kingdom prison service for fighting fires in cells and accommodation areas and in the food industry for effectively dealing with fires in waste bins and fryers. First reaction mobile watermist fire fighting system that can be quickly deployed around any building Easy to use lance and controls Guaranteed 5 minutes of fire suppression Reduced water use and residual water damage Dramatically reduces smoke spread from the fire Proven in extensive testing with the UK Building Research Establishment and the Ministry of Justice to provide a life sustainable environment whilst in use Hydramist fire suppression nozzles are designed and tested to provide fast and effective fire suppression to a wide range of applications. Heat sensitive frangible bulbs from C Open nozzles for deluge applications Varied flow rates to match applications Food safe stainless steel nozzle protection caps Individually numbered to provide traceability Precision manufactured from stainless steel to give long service life 06 T: +44 (0) Product Range

7 fire suppression products (please note images are not to scale) Kitchen fire suppression in10 seconds 15AMPU Designed primarily for fire suppression on deep fat fryers in commercial kitchens, the Hydramist 15AMPU has been tested and approved by the LPCB LPS1223 standard. The Hydramist 15AMPU offers fast and effective suppression and extinguishing, is safe for people and the environment and dramatically reduces the spread of smoke from a fire. Fast acting and effective fire suppression system with both automatic and manual operation Tested and approved to LPCB LPS1223 Continuous operation until manually stopped Reduced water use and residual water damage Dramatically reduces smoke spread from the fire Easy to install Cost effective Kitchen area returned to normal within minutes of a fire Stainless Steel case to meet food standards finish and match styling of existing kitchen equipment W: Product Range 07

8 UK Supreme Court Law library Located in Westminster, London, the Westminster Guildhall is of historic interest dating back to The building was closed in March 2007 for refurbishment and conversion to the United Kingdom Supreme Court. As part of the these works The Ministry of Justice required a 21st century fire protection system to protect the nationally important central law library within the main building. A key requirement of the design was that the fire protection system should be largely unseen, blending in with the antique style library furniture and bookshelves. Live fire tests with the Hydramist system demonstrated that stored materials suffered very minimal water damage and it was noted that the Hydramist system provided a greater level of fire suppression than other competing suppression systems. The requirement for minimal aesthetic impact of the system was easily satisfied by incorporating the nozzles within an existing suspended light rail. The Hydramist system supply piping was hidden above the bookcases and behind architectural wall mountings. The overall project Architects, Feilden & Mawson, were impressed by the experience and data that Hydramist Limited were able to provide to ensure that this project was carried out smoothly and to the entire satisfaction of all parties. Following competitive evaluation and extensive testing, Hydramist was selected for this project. 08 T: +44 (0) Case Studies

9 HM Prison Service The HM Prison Service commissioned a set of tests to determine the effectiveness of the traditional hose reels which, to date, had been installed in prisons across England and Wales throughout the 20th century. During these tests it was observed that the conventional hose reels did not effectively fight the fire and that smoke from the fire presented a greater risk to both the cell occupants and rescuers than the fire itself. The use of conventional hose reels also created extensive water damage and extended turnaround time of the affected cell in some cases the cell below as well. Knowing that Hydramist systems offer a far more efficient way of using water to fight fires, the HM Prison Service asked us to participate in a series of evaluation trials to determine the effectiveness of Hydramist systems, these were held at the world renowned Buildings Research Establishment (BRE). The BRE test criteria established were: maintain a tenable atmosphere for a period of 20 minutes when fire tested in accordance with the specifications discharge a relatively small amount of water deliver a spray of water mist with sufficient momentum to discharge droplets to the back wall of a cell The inundation was to last for 5 minutes after pre-burn and operation of internal cell fire detection systems, then a simulated rescue of an inmate involving opening the door for a set period of one minute would occur, followed by re-closing the door and waiting 10 minutes during which time the fire was not to resume. Hydramist tested the products as follows: Mobile 8 and Hosereel mounted hand held lances Fixed in cell nozzle with glass frangible bulb operation using a locally mounted pump unit In all tests Hydramist : Successfully extinguished the fire at the first attempt Dramatically reduced cell temperature, toxic gases and smoke to tenable levels Ensured sufficient oxygen was available to sustain life throughout the cell Note: During the rescue and ten minute waiting period after inundation that the fire did not resume; temperatures and toxic gases in the cell continued to fall, remaining well below levels that could be harmful to life. Since successfully passing these tests Hydramist systems have become the equipment of choice for The HM prison Service and are installed in over 150 prisons. W: Case Studies 09

10 Network Rail Archive Store The very latest Hydramist technology for fire fighting has been used to ensure historic and valuable documents held in the network rail central archive store are protected by the most effective and efficient means. The bespoke warehouse archive facility contains an irreplaceable collection of rail-related documents dating back well over a hundred years-using The Hydramist system network rail knew that they would be protected by a 21st century fire protection and detection system. A requirement of the design was that the fire protection system should protect each individual storage area separately and be able to detect smoke before it was visible to the human eye. The Hydramist high pressure system was linked to VESdA (Very Early Smoke detection Aspirator) detection in the archive areas and conventional point type detection in the escape routes, corridors and stairs. It was observed that fires started in various positions within a scaled section of a typical archive store were quickly controlled by the Hydramist system preventing the fire from spreading and containing the smoke to the affected area only. Additionally it was observed that the precious archive documents stored adjacent to the fire source were safe throughout the tests as there was zero water penetration to the document containers. Crucially, the tests showed that this was the right solution for the archive being both effective at fighting fire and safe for the document storage application. A series of fire tests were designed and carried out by Hydramist Limited in accordance with the guide-lines of NFPA750 and the specific requirement of Network Rail under the supervision of their designated fire risk consultant. 10 T: +44 (0) Case Studies

11 Commercial Kitchen Systems Until now restaurant fryer fire protection systems have traditionally used dry powder or wet chemical fire suppression systems as a fire suppression medium. However these traditional systems can leave a large amount of potentially hazardous residues from the fire suppression agent on the catering equipment which must be cleaned up before cooking can re-commence. This leaves a restaurant without a kitchen during this period. Using atomised normal drinking water the Hydramist 15AMPU high pressure Watermist fire extinguishing systems act quickly to extinguish the fire and prevent re-ignition by cooling the oil and hot metal surfaces. The Hydramist systems very fine droplets of water turn to steam upon contact with the flames. The steam created then smothers the fire by displacing oxygen at the flame front to extinguish the fire. After extinguishment the mist evaporates latent heat away to prevent re-ignition. As the droplets are very fine no water can come into contact with the oil until the oil temperature is below 100c removing any risk of splashing. To verify fire performance, safety, and system durability the Hydramist 15AMPU system has successfully completed LPCB LPS1223 accreditation carried out and witnessed by the Building Research Establishment (BRE). Hydramist is the first high pressure Watermist product in the world to be included in the highly regarded LPCB Red Book for LPS1223 approved Kitchen Suppression Systems. Hydramist 15AMPU Systems have been installed for many well-known and prestigious clients including: Greggs the Bakers Rocco Forte hotels Sheffield University ITV KP Foods Brighton and Hove FC Norwich Open Academy Browns hotel of Mayfair Sanderson Hotel The Hydramist 15AMPU Kitchen Suppression System offers a cost effective fast reacting solution to this fire risk. Using a wall mounted Hydramist pump also eliminates storage issues for the fire suppression equipment. To see the 15AMPU in action visit After activation next to no clean-up is necessary as the extinguishing agent is clean water allowing the kitchen to be back in operation extremely quickly. W: Case Studies 11

12 Hydramist Fison Way, Thetford, Norfolk IP24 1HJ United Kingdom T: +44 (0) E: W: Hydramist is a trading name of Watermist Ltd a company registered in England Registration number

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS FIRE EXTINGUISHING INSTALLATIONS SECTION POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS Version 1 29-09-04 0 Eurofeu position paper on water mist for fire fighting applications 1 Scope The

More information

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

I wish I could protect my business with the most suitable Water Mist solution to fit my needs. I wish I could protect my business with the most suitable Water Mist solution to fit my needs. Wish granted! Tyco AquaMist systems are a versatile and highly efficient fire-fighting resource, featuring

More information

How to know if a residential or domestic water mist system is performance compliant to BS 8458:2015?

How to know if a residential or domestic water mist system is performance compliant to BS 8458:2015? Plumis White Paper April 2017 How to know if a residential or domestic water mist system is performance compliant to BS 8458:2015? As with the introduction of every new formal product category through

More information

K Series - Fire Suppression Systems for the Catering Industry

K Series - Fire Suppression Systems for the Catering Industry K Series - Fire Suppression Systems for the Catering Industry Technical Overview The System Concept The K-Series fire protection systems are fully engineered and as such are designed to meet the individual

More information

HI-FOG for buildings. Technical introduction. Protecting people, property and business continuity. Jussi Tiainen

HI-FOG for buildings. Technical introduction. Protecting people, property and business continuity. Jussi Tiainen HI-FOG for buildings Technical introduction Jussi Tiainen Protecting people, property and business continuity Contents Introduction to HI-FOG...3 How HI-FOG fights fire...4 Principles of HI-FOG system

More information

Fire Protection of Hotels. With SEM-SAFE High-Pressure Water Mist System

Fire Protection of Hotels. With SEM-SAFE High-Pressure Water Mist System Fire Protection of Hotels With SEM-SAFE High-Pressure Water Mist System Danfoss Semco A/S Total Solution Provider of Certified Fixed Fire Fighting Systems Aesthetic design and reliability with SEM-SAFE

More information

Fire protection for buildings

Fire protection for buildings Fire protection for buildings HI-FOG high-pressure water mist Ghelamco Group Protecting people, property and business continuity A fire in a building can lead to serious consequences. Even a harmless fire

More information

The Route to Third Party Certification

The Route to Third Party Certification www.fia.uk.com INTRODUCTION If you work in any part of the fire safety industry you will at least have heard of Third Party Certification (TPC) but you may not be too sure what it is. Even if you work

More information

Tudor House, Kingsway Business Park Oldfield Road, Hampton, Middlesex, TW12 2HD Phone: +44 (0) Website:

Tudor House, Kingsway Business Park Oldfield Road, Hampton, Middlesex, TW12 2HD Phone: +44 (0) Website: Fact File No 0055 Tudor House, Kingsway Business Park Oldfield Road, Hampton, Middlesex, TW12 2HD Phone: +44 (0)20 3166 5002 Website: www.fia.uk.com Watermist Systems 1. INTRODUCTION Over the past twenty

More information

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants Branch Solution Wood based panel plants Fire protection solutions for wood based panel plants afety throughout the production process R The versatility of wood as a raw material and the fact that it is

More information

FIRE SAFETY IN THE HOME

FIRE SAFETY IN THE HOME FIRE SAFETY IN THE HOME Did you know? You re twice as likely to die in a fire if you don t have a smoke alarm that works. 90 people die each year because the battery in their smoke alarm was flat or missing.

More information

GAS EXTINGUISHING SYSTEMS INERT GAS. Argotec with argon or nitrogen

GAS EXTINGUISHING SYSTEMS INERT GAS. Argotec with argon or nitrogen GAS EXTINGUISHING SYSTEMS INERT GAS Argotec with argon or nitrogen NATUR AL without any damage to the atmosphere The extinguishing gases Argon and nitrogen extinguish a fire by oxygen displacement. When

More information

Highly Protected Risks in Power Generation Stewart Kidd outlines the issues to consider when installing active fire suppression in power stations THE

Highly Protected Risks in Power Generation Stewart Kidd outlines the issues to consider when installing active fire suppression in power stations THE Highly Protected Risks in Power Generation Stewart Kidd outlines the issues to consider when installing active fire suppression in power stations THE TERM highly protected risk (HPR) is commonly used in

More information

Special solution KS marine. Kitchen protection system KS marine Fire prevention for galleys

Special solution KS marine. Kitchen protection system KS marine Fire prevention for galleys Special solution KS 2000-8 marine Kitchen protection system KS 2000-8 marine Fire prevention for galleys RiskDeep fat fryer fire Safety requirements for passengers and crew are especially high at sea.

More information

Retail solutions by Tenos. Value engineered fire safety solutions for landmark retail developments.

Retail solutions by Tenos. Value engineered fire safety solutions for landmark retail developments. retail expertise Retail solutions by Tenos In large open spaces, occupied by people who may be unfamiliar with their surroundings, retail properties can present a unique set of challenges when considering

More information

Ceasefire Watermist Hydrant Systems

Ceasefire Watermist Hydrant Systems No fire is too big to beat. Ceasefire Watermist Hydrant Systems Never underestimate a fire. With enough oxygen and other fuels, even the smallest flame can turn into a full-scale blaze, destroying everything

More information

FIRE SAFETY IN THE HOME

FIRE SAFETY IN THE HOME FIRE SAFETY IN THE HOME 2 Did you know? You re four times more likely to die in a fire if you don t have a smoke alarm that works. 21 people die each year because the battery in their smoke alarm was flat

More information

Building Services Brochure

Building Services Brochure Building Services Brochure A Midland Brand A Midland Brand Redefining Flow Control Contents Section Page Introduction to Building Services 3 Wet & Dry RIser Equipment 4 Gas Detection & Pressure Proving

More information

PORTABLE FIRE EXTINGUISHERS. Fire Safety.

PORTABLE FIRE EXTINGUISHERS. Fire Safety. WHAT THE RATINGS MEAN: The New Zealand Standard for classifiying, rating, and performance testing of Fire Extinguishers (AS/NZ1850:1997), was introduced at the request of manufacturers, who wanted a method

More information

Aspirating Smoke Detection (ASD) Systems Fire Detection

Aspirating Smoke Detection (ASD) Systems Fire Detection Aspirating Smoke Detection (ASD) Systems Fire Detection A complete guide for the fire system specifier, designer and installer Aspirating Smoke Detection WAGNER UK Limited Better Solutions in Fire Protection

More information

FOREFRONT AT THE OF PROTECTION

FOREFRONT AT THE OF PROTECTION AT THE FOREFRONT OF PROTECTION SIEX WF B combines the benefits of water as an extinguishing agent with the most innovative advances to achieve fire protection causing the least possible damage and exceeding

More information

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES  LEADING THE WAY IN FIRE PROTECTION FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION MEANS OF ESCAPE PROTECTION CASE STUDY: SSE HYDRO GLASGOW UK

More information

Employers Responsibilities

Employers Responsibilities Why? Fire Kills! Each year 700 people die as a result of fires in their own homes A further 14000 are injured The best way to avoid danger is to prevent fire starting in the first place Legislation Fire

More information

Water mist fire suppression systems. Minifog ProCon Low-pressure water mist system

Water mist fire suppression systems. Minifog ProCon Low-pressure water mist system Water mist fire suppression systems Minifog ProCon Minifog ProCon Low-pressure water mist system IRE PROTECTION Efficient even for non-enclosed equipment Minifog ProCon systems by Minimax use innovative

More information

Watermist Systems. Versatile, Affordable Water Mist Fire Suppression. your TRUSTED partner in fire safety

Watermist Systems. Versatile, Affordable Water Mist Fire Suppression. your TRUSTED partner in fire safety Watermist Systems Versatile, Affordable Water Mist Fire Suppression your TRUSTED partner in fire safety A New Era in Water-Based Fire Protection Water is the safe, natural way to extinguish a fire. But,

More information

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES  LEADING THE WAY IN FIRE PROTECTION FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION DESIGN SOLUTIONS THAT WORK FOR YOU CASE STUDY: FORTNUM & MASON LONDON UK Active Fire Curtain Barrier

More information

GAS EXTINGUISHING SYSTEM INERT GAS. Argotec with carbon dioxide. Safe for certain.

GAS EXTINGUISHING SYSTEM INERT GAS. Argotec with carbon dioxide. Safe for certain. GAS EXTINGUISHING SYSTEM INERT GAS Argotec with carbon dioxide Safe for certain. PPLICATIO VERSATILE Reliable extinguishing Fighting fires quickly and effectively is the strong point of Argotec extinguishing

More information

PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers

PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers READY FOR ACTION WHEN YOU ARE. Every year, cooking accidents, unattended candles, electrical failures, careless smoking and other incidents

More information

Fire protection solutions for ships and offshore facilities BRANCH SOLUTION

Fire protection solutions for ships and offshore facilities BRANCH SOLUTION Fire protection solutions for ships and offshore facilities BRANCH SOLUTION SAFETYCompetent Ships and offshore facilities such as oil platforms require an above-average level of safety due to the special

More information

Fire Protection for Catering Kitchens KS 2000 Compact Extinguishing System. Safe for certain.

Fire Protection for Catering Kitchens KS 2000 Compact Extinguishing System. Safe for certain. SPECIAL EXTINGUISHING SYSTEMS COMPACT EXTINGUISHING SYSTEMS Fire Protection for Catering Kitchens KS 2000 Compact Extinguishing System Safe for certain. ISK DETECTION Catering kitchens tend to use large

More information

Fire Protection for Catering Kitchens KS 2000 Compact Extinguishing System. Safe for certain.

Fire Protection for Catering Kitchens KS 2000 Compact Extinguishing System. Safe for certain. SPECIAL EXTINGUISHING SYSTEMS COMPACT EXTINGUISHING SYSTEMS Fire Protection for Catering Kitchens KS 2000 Compact Extinguishing System Safe for certain. ISKS IDENTIFYING Catering kitchens tend to use large

More information

Safe, Effective, Environment-friendly

Safe, Effective, Environment-friendly IG-55 (Argon/Nitrogen) Safe, Effective, Environment-friendly Introduction With the phase out of the most commonly used but environmentally damaging Halon 1301 and CO 2 fire suppressant, inert gases are

More information

Fire protection solutions for ships and offshore facilities

Fire protection solutions for ships and offshore facilities Experts in fire protection Fire protection solutions for ships and offshore facilities BRANCH SOLUTION MARINE OVERVIEW Top level of safety on board Minimax has been one of the leading fire protection brands

More information

WATER SPRAY EXTINGUISHING SYSTEMS

WATER SPRAY EXTINGUISHING SYSTEMS WATER SPRAY EXTINGUISHING SYSTEMS FEUERSCHUTZ UND SICHERHEIT THE NATURAL WAY TO PROTECT TECHNOLOGY AND THE ENVIRONMENT Wherever water can be used as an extinguishing agent, it is the preferred choice of

More information

and Sprinkler System in Resalat Tunnel of Tehran

and Sprinkler System in Resalat Tunnel of Tehran CFD Simulation of Water Mist and Sprinkler System in Resalat Tunnel of Tehran Motivation Resalat tunnel is the first road tunnel in Tehran one of most crowded tunnels of Tehran my every day route, home

More information

Mechanical Smoke Extract Shaft Systems

Mechanical Smoke Extract Shaft Systems Mechanical Smoke Extract Shaft Systems Presented by Mechanical Smoke Extract Shaft Systems Why Choose Crossflow? Crossflow is a family run company with over 45 years technical expertise. We are a solutions

More information

Case study: EconAqua water mist sprinkler system

Case study: EconAqua water mist sprinkler system 1.1 Minimax's Econ Aqua low pressure mist system Low pressure water mist extinguishing system based on sprinkler technology with particularly low consumption of water, thus providing great benefits for

More information

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES  LEADING THE WAY IN FIRE PROTECTION FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION DESIGN SOLUTIONS THAT WORK FOR YOU CASE STUDY: FORTNUM & MASON LONDON UK Active Fire Curtain Barrier

More information

CO 2 EXTINGUISHING SYSTEMS

CO 2 EXTINGUISHING SYSTEMS CO 2 EXTINGUISHING SYSTEMS CO 2 THE FIRE EXTINGUISHING CLASSIC: CLEAN, FAST AND RELIABLE TOTAL WALTHER, the acknowledged specialist in fire protection systems, has been manufacturing CO 2 extinguishing

More information

Oxeo extinguishing systems

Oxeo extinguishing systems Experts in fire protection Oxeo extinguishing systems TECHNOLOGIES GAS EXTINGUISHING SYSTEMS Residue-free fire extinguishing Oxeo extinguishing systems from Minimax use nitrogen and argon to fight fire.

More information

GAS EXTINGUISHING SYSTEMS INERT GAS. Argon Extinguishing Systems. Fire Protection Systems

GAS EXTINGUISHING SYSTEMS INERT GAS. Argon Extinguishing Systems. Fire Protection Systems GAS EXTINGUISHING SYSTEMS Argon Extinguishing Systems Fire Protection Systems EFFECTIVE NATURAL no damage to the atmosphere technology for complex applications EXAMPLE GAS EXTINGUISHING SYSTEMS solution

More information

asphalt applications European Asphalt Standards and their application in the UK mpa asphalt Asphalt Information Service Mineral Products Association

asphalt applications European Asphalt Standards and their application in the UK mpa asphalt Asphalt Information Service Mineral Products Association asphalt applications 12 European Standards and their application in the UK Information Service mpa asphalt November 2009 Mineral Products Association PD 6691 and the BS EN 13108 series Wherever a reference

More information

Portable wet chemical extinguishers

Portable wet chemical extinguishers Wet Chemical Extinguisher 6 liter AF Portable wet chemical extinguishers Wet chemical extinguishers are the best restaurant kitchen appliance hand portable fire extinguishers you can purchase. Each model

More information

Notifier by Honeywell: SMART Detection. SMART Detection. The Ultimate in False Alarm Technology...Make the SMART choice

Notifier by Honeywell: SMART Detection. SMART Detection. The Ultimate in False Alarm Technology...Make the SMART choice SMART Detection The Ultimate in False Alarm Technology......Make the SMART choice How much would a false alarm cost your business? False alarms from fire detection systems are not only a nuisance but can

More information

Loss Prevention Standard

Loss Prevention Standard Loss Prevention Standard LPS 1196: Issue 1.2 This Loss Prevention Standard is the property of BRE Global Ltd. and is made publicly available for information purposes only. Its use for testing, assessment,

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL SPECIFICATION SPÉCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION CEN/TS 14972 May 2008 ICS 13.220.20 English Version Fixed firefighting systems - Watermist systems - Design and installation Installations

More information

FIRE SAFETY IN THE HOME

FIRE SAFETY IN THE HOME FIRE SAFETY IN THE HOME In case of fire call 190 HM Government of Gibraltar Issued by the Gibraltar Fire & Rescue Service on behalf of the Civil Contingencies Committee Did you know...? You are twice as

More information

FIRE SAFETY LOG BOOK

FIRE SAFETY LOG BOOK FIRE SAFETY LOG BOOK Regulatory Reform (Fire Safety) Order 2005 If you own, manage or operate a business, you will need to comply with fire safety law. The main law is the Regulatory Reform (Fire Safety)

More information

FULL RANGE EXPERTISE FIRE PUMPS FOR EVERY STANDARD

FULL RANGE EXPERTISE FIRE PUMPS FOR EVERY STANDARD GRUNDFOS FIRE PROTECTION SYSTEMS Grundfos is a full-line fire system supplier that fully complies with a globally recognised list of approvals and listings. We design, manufacture and service our fire

More information

English.

English. www.atex100.com English For more than 25 years Detection Venting Suppression Isolation 2 ATEX Who isn t aware of the ATEX Directive EG ATEX 2014/34/EU? Ahead of his time, engineer Dr. Franz Alfert was

More information

Risk Management Department. Fire Extinguishers

Risk Management Department. Fire Extinguishers Risk Management Department Fire 1 Introduction to Fire Every school facility is equipped with fire extinguishers for staff to use to suppress fires. Used properly, a fire extinguisher can be an effective

More information

AMBIRAD.... Vision Radiant Tube Heating Systems...

AMBIRAD.... Vision Radiant Tube Heating Systems... AMBIRAD Vision Radiant Tube Heating Systems * Vision... Radiant Tube Heating Systems... Renowned for its pioneering track record, AmbiRad, Europes leading supplier of radiant tube heating systems, has

More information

Press Presse Press Presse

Press Presse Press Presse Press Presse Press Presse Industry Sector Building Technologies Division Copenhagen (Denmark), June 10, 2010 Innovation safeguards Tradition Integrated fire safety solutions from Siemens reliably protects

More information

Project Name: Project Address: Installer Name: Installer Address: Date of Inspection:

Project Name: Project Address: Installer Name: Installer Address: Date of Inspection: FIRE DEPARTMENT Kitchen Range Hood Fire Suppression System Acceptance Test Project Name: Project Address: Installer Name: Installer Address: Date of Inspection: DOCUMENTATION NO Plans have been reviewed

More information

ON-TRACK FOR TAILORED FIRE PROTECTION. Future-proof fire protection solutions for rail vehicles

ON-TRACK FOR TAILORED FIRE PROTECTION. Future-proof fire protection solutions for rail vehicles ON-TRACK FOR TAILORED FIRE PROTECTION Future-proof fire protection solutions for rail vehicles Fire detection systems Extinguishing systems Water mist systems Challenges FIRE PROTECTION IN RAIL VEHICLES.

More information

SHIPBUILDING FIRE PROTECTION WATER MIST SYSTEM SAID. DONE!

SHIPBUILDING FIRE PROTECTION WATER MIST SYSTEM SAID. DONE! SHIPBUILDING FIRE PROTECTION WATER MIST SYSTEM The KJ FireOff Water Mist System The special conditions at sea mean that safety is an incredibly important issue for ships. Ships are subject to a whole range

More information

+91-8048763768 Cease Fire & Electrical Services http://www.ceasefireengineers.com/ We are the supplier, trader and service provider of fire alarm equipment, fire suppression system, fire detection system,

More information

University of London

University of London University of London Senate House and Stewart House Fire safety arrangements Contents 1. Introduction p.2 2. Fire Risk Assessment documentation p.2 3. Action to be taken by a person discovering a fire

More information

Fire Safety Register

Fire Safety Register Fire Safety Register Introduction 1.1 Section 18(2) of the Fire Services Acts, 1981 and 2003 generally applies to all premises other than a dwelling house occupied as a single private dwelling. This section

More information

technical specification smoke venting systems

technical specification smoke venting systems technical specification smoke venting systems An Introduction to FDS FDS sets the standards the rest of the industry follows Providing a complete service for all of your smoke ventilation system needs.

More information

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection Aerosol Fire Suppression Your Choice for Special Hazard Fire Protection Maintenance Costs Over 10 Years Service call: $785/day Stat-X Dry Chemical CO2 Halocarbon Inert Gas Water Mist 0 $5,000 $10,000 $15,000

More information

FIRE DOORS - GENERAL UCL OVERVIEW AND REQUIREMENTS

FIRE DOORS - GENERAL UCL OVERVIEW AND REQUIREMENTS Fire Safety Technical Note FIRE DOORS - GENERAL UCL OVERVIEW AND REQUIREMENTS Fire Door Provision In UCL Buildings - what you need to know: Mandatory - all doors on main traffic and circulation routes,

More information

How can you minimize consequential damages in case of a fire?

How can you minimize consequential damages in case of a fire? How can you minimize consequential damages in case of a fire? With intelligent extinguishing solutions from Siemens. Sinorix 227 fast, effective, and reliable. Answers for infrastructure. Reliability the

More information

Where EXCESSIVE reduce the number of ignition sources such as: ACTIONS TAKEN/TO BE TAKEN:-*

Where EXCESSIVE reduce the number of ignition sources such as: ACTIONS TAKEN/TO BE TAKEN:-* Snowtraxx International General Hotel Risk Assessments 2015/16 Version Date: Hotel: Resort: Staff Name: Fire Prevention Where EXCESSIVE reduce the number of ignition sources such as: by the outbreak of

More information

SAFETY FIRST INTERNATIONAL

SAFETY FIRST INTERNATIONAL YOUR KITCHEN S ACTIVE GUARD SAFETY FIRST INTERNATIONAL SAFETY FIRST INTERNATIONAL has been selecting and developing fire prevention systems for professional kitchen systems known across the world since

More information

ADVICE NOTE FIRE SAFETY IN FLATS. A general guide to fire safety in blocks of flats

ADVICE NOTE FIRE SAFETY IN FLATS. A general guide to fire safety in blocks of flats ADVICE NOTE FIRE SAFETY IN FLATS A general guide to fire safety in blocks of flats 2 CONTENTS Note: As the leading trade body for residential leasehold management, ARMA is also an important resource for

More information

FM Approvals & Water Mist Systems. Paul Bardsley Engineer, FM Approvals

FM Approvals & Water Mist Systems. Paul Bardsley Engineer, FM Approvals FM Approvals & Water Mist Systems Paul Bardsley Engineer, FM Approvals Presentation Outline Introduction to FM Global Introduction to FM Approvals FM 5560 - Water Mist Systems Who are FM Global? The largest

More information

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco. TN-25 Tunnel Fire Protection System Safer. Smarter. Tyco. Expert Fire Protection for Tunnels Tyco provides a complete fire protection solution to protect the infrastructure of tunnels. Whether it is rail,

More information

Fire extinguishers. Amicus guide

Fire extinguishers. Amicus guide Fire extinguishers Amicus Hayes Court, West Common Road, Hayes, Bromley, Kent BR2 7AU Tel: 020 8462 7755 Fax: 020 8315 8234 Website: www.amicustheunion.org Amicus guide October 2005 Amicus guide to fire

More information

incorporating Guidance to Shafts for Smoke Control A useful guide to practical smoke shaft principals and specifications

incorporating Guidance to Shafts for Smoke Control A useful guide to practical smoke shaft principals and specifications incorporating Guidance to Shafts for Smoke Control A useful guide to practical smoke shaft principals and specifications Smoke shafts - an overview Scope of this guide Smoke shaft is the common term for

More information

Allianz Engineering Inspection Services Ltd. Electrical Services. Product Information

Allianz Engineering Inspection Services Ltd. Electrical Services. Product Information Allianz Engineering Inspection Services Ltd Electrical Services Product Information Electrical Testing and Inspection Services The Electricity at Work Regulations (EaWR) states that all electrical systems

More information

Technologies Fire Prevention Systems. Oxeo Prevent Oxygen Reduction System Active Fire Prevention using natural Nitrogen

Technologies Fire Prevention Systems. Oxeo Prevent Oxygen Reduction System Active Fire Prevention using natural Nitrogen Technologies Fire Prevention Systems Oxeo Prevent Oxygen Reduction System Active Fire Prevention using natural Nitrogen fire prevention Active prevention instead of firefighting Active fire prevention

More information

ESSENTIAL INSTALLATIONS

ESSENTIAL INSTALLATIONS www.mcduk.co.uk ESSENTIAL INSTALLATIONS the best choice for the house builder and kitchen manufacturer for the supply, delivery and installation of kitchen appliances A COMPLETE ON-SITE APPLIANCE SERVICE

More information

FIRE SAFETY PRACTICES AND PROCEDURES

FIRE SAFETY PRACTICES AND PROCEDURES FIRE SAFETY PRACTICES AND PROCEDURES One of the most costly and destructive causes for loss of life and property that the City could experience would be from a major fire. Reporting Fires All employees

More information

Press Release. Cordless vacuuming full of power The new Athlet Ultimate from Bosch

Press Release. Cordless vacuuming full of power The new Athlet Ultimate from Bosch Cordless vacuuming full of power The new Athlet Ultimate from Bosch June, 2017 Bosch lithium-ion technology: long-lasting, powerful rechargeable batteries with extra-long run time and short charging time

More information

FIRE SAFETY IN PURPOSE BUILT BLOCKS OF FLATS

FIRE SAFETY IN PURPOSE BUILT BLOCKS OF FLATS A GUIDE ON FIRE SAFETY IN PURPOSE BUILT BLOCKS OF FLATS INTRODUCTION Fire safety in blocks of flats is something that must be taken very seriously. The Local Government Group (LGG) was commissioned to

More information

Fire Door Maintenance Guide.

Fire Door Maintenance Guide. Fire Door Maintenance Guide http://www.c-sgroup.co.uk/products/acrovyn-impact-resistant-doors/ Introduction Fire Doors are a critical safety feature of any building in which people work or visit, as they

More information

Fire Risk Assessment (FRA) Checklist

Fire Risk Assessment (FRA) Checklist Fire Risk Assessment (FRA) Checklist Assessed by: Job Title: Department/Location: Date Document Downloaded: Date of Assessment: Duty Holder Name: FRA. Description / Comments FHRA. 1. MANAGEMENT, PLANNING

More information

Level 5 Fire Engineering Design. Courses and qualification

Level 5 Fire Engineering Design. Courses and qualification Level 5 Fire Engineering Design Courses and qualification Xact Consultancy and Training Limited T: 01386 277980 F: 0845 0941 887 qualifications@xact.org.uk www.xact.org.uk XFS-2018 Level 5 Qualification:

More information

+91-8079454431 Akasa International http://www.akasainternational.com/ We are the only manufacturers providing with widest range of INDIAN made Commercial Kitchen Equipments. Our provided facilities sustain

More information

What are the four things that must be present at the same time to produce fire?

What are the four things that must be present at the same time to produce fire? What are the four things that must be present at the same time to produce fire? Enough oxygen to sustain combustion, Enough heat to raise the material to its ignition temperature, Some sort of fuel or

More information

ARCHIVED DOCUMENT. Reducing catering costs through energy efficiency. A guide for kitchen designers, contract caterers and operators

ARCHIVED DOCUMENT. Reducing catering costs through energy efficiency. A guide for kitchen designers, contract caterers and operators GOOD PRACTICE GUIDE 222 Reducing catering costs through energy efficiency A guide for kitchen designers, contract caterers and operators Increased profits/savings More comfortable working conditions GOOD

More information

Loss Prevention Standard

Loss Prevention Standard Loss Prevention Standard LPS 1500: Issue 2.1 provide compartmentation in buildings This standard defines the requirements for companies installing fire resisting compartment systems approved by LPCB to

More information

Exhaust Duct Design Page 1 of (C)

Exhaust Duct Design Page 1 of (C) Exhaust Duct Design Page 1 of 16 2016-10-07 (C) Oven Exhaust Guide Version: R5 Exhaust Duct Design The following section is for your guidance in establishing a design to suit your Exhaust duct design requirements.

More information

from the world leaders manufacturing over 35 million smoke, heat and carbon monoxide alarms every year

from the world leaders manufacturing over 35 million smoke, heat and carbon monoxide alarms every year Cl/SfB (68.52) Uniclass L7625 September 2012 A UTC Fire & Security Company Your one-stop solution for hard-wired and sealed-in battery smoke and CO alarms from the world leaders manufacturing over 35 million

More information

FIRE SAFETY LOGBOOK PREMISES ADDRESS: LOG BOOK TO BE KEPT IN THIS LOCATION: DSFRS Log book Version 1.0 (October 2007)

FIRE SAFETY LOGBOOK PREMISES ADDRESS: LOG BOOK TO BE KEPT IN THIS LOCATION: DSFRS Log book Version 1.0 (October 2007) FIRE SAFETY LOGBOOK PREMISES ADDRESS: LOG BOOK TO BE KEPT IN THIS LOCATION: AN INTRODUCTION TO YOUR LOG BOOK. This Fire Safety Log book has been prepared to assist the responsible person in coordinating

More information

Portable Fire Extinguishers

Portable Fire Extinguishers Portable Fire Extinguishers Objectives (1 of 2) State the primary purposes of fire extinguishers. Define Class A fires. Define Class B fires. Define Class C fires. Define Class D fires. Define Class K

More information

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS 12 December 1996 Ref. T4/4.01 GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS 1 The Maritime Safety

More information

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE EMERGENCY PLAN

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE EMERGENCY PLAN REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE EMERGENCY PLAN This Emergency Plan has been developed following fire risk assessments of the relevant building. The purpose of the Plan is to ensure the

More information

Fire Policy and Procedures. Cañada Blanch Spanish School

Fire Policy and Procedures. Cañada Blanch Spanish School Fire Policy and Procedures Cañada Blanch Spanish School SUMMARY 1. Introduction (p. 3) 2. Roles and responsibilities (p. 3) -- Headteacher -- Fire Team -- All staff -- Contractors 3. Fire procedures (p.

More information

Guidance Document on Caravan and Camping Sites Fire Safety Equipment Requirements

Guidance Document on Caravan and Camping Sites Fire Safety Equipment Requirements Guidance Document on Caravan and Camping Sites Fire Safety Equipment Requirements FIA Guidance for the Fire Protection Industry This Guidance Note is intended as a general guidance and is not a substitute

More information

Fixed Fire Extinguishing Equipment and Systems

Fixed Fire Extinguishing Equipment and Systems Fixed Fire Extinguishing Equipment and Systems Sea Term 2016 Massachusetts Maritime Academy January 2016 DESIGN AND INSTALLATION OF FTXED SYSTEMS Fire extinguishing systems are designed and installed

More information

Increasing Fire Safety of Cologne Main Station by High Pressure Water Mist

Increasing Fire Safety of Cologne Main Station by High Pressure Water Mist Increasing Fire Safety of Cologne Main Station by High Pressure Water Mist Dipl.-Ing. Rüdiger Kopp FOGTEC Fire Protection ruediger.kopp@fogtec.com 1 Background of this Presentation In recent years the

More information

KTDC HOTELS & RESORTS LIMITED MASCOT SQUARE, TRIVANDRUM - 33

KTDC HOTELS & RESORTS LIMITED MASCOT SQUARE, TRIVANDRUM - 33 EMPANELMENT OF ARCHITECTS / LANDSCAPING CONSULTANT / INTERIOR DESIGNER / EVENT MANAGERS / TOURISM CONSULTANT SCOPE OF WORKS 1. Introduction It is essential to have plan for development of Tourism Destinations

More information

A Guide to the Selection of Smoke Seals for Doorsets. Information Sheet No. 5. Intumescent Fire Seals Association

A Guide to the Selection of Smoke Seals for Doorsets. Information Sheet No. 5. Intumescent Fire Seals Association Information Sheet No. 5 Intumescent Fire Seals Association A Guide to the Selection of Smoke Seals for Doorsets THE HOME OF REACTIVE PROTECTION SYSTEMS CONTENTS Page Introduction 1 Purpose of smoke seals

More information

GUIDELINES FOR THE APPROVAL OF HELICOPTER FACILITY FOAM FIRE-FIGHTING APPLIANCES

GUIDELINES FOR THE APPROVAL OF HELICOPTER FACILITY FOAM FIRE-FIGHTING APPLIANCES E 4 ALBERT EMBANKMENT LONDON SE1 7SR Telephone: +44 (0)20 7735 7611 Fax: +44 (0)20 7587 3210 GUIDELINES FOR THE APPROVAL OF HELICOPTER FACILITY FOAM FIRE-FIGHTING APPLIANCES MSC.1/Circ.1431 31 May 2012

More information

Fire Safety Policy Date: 0

Fire Safety Policy Date: 0 Fire Safety Policy Date: 0 Policy Preparation & Introduction This document format has been produced by Firesafe Solutions (UK) Ltd to aid managers, tenants and others responsible for fire safety in their

More information

AMBASSADOR HOUSE. A guide on. Fire Safety in Purpose Built Blocks of Flats

AMBASSADOR HOUSE. A guide on. Fire Safety in Purpose Built Blocks of Flats AMBASSADOR HOUSE A guide on Fire Safety in Purpose Built Blocks of Flats INTRODUCTION Fire safety in blocks of flats is something that must be taken very seriously. The Local Government Group (LGG) was

More information

Water Mist Fire Protection Systems for the Protection of Industrial Oil Cookers. 8th March 2016 Dr Tim Nichols CPhys MIFireE

Water Mist Fire Protection Systems for the Protection of Industrial Oil Cookers. 8th March 2016 Dr Tim Nichols CPhys MIFireE Water Mist Fire Protection Systems for the Protection of Industrial Oil Cookers 8th March 2016 Dr Tim Nichols CPhys MIFireE Industrial Oil Cookers 2 What are Industrial Oil Cookers Large cooker of food

More information