Occupational Health & Safety Practitioner. Reading BUILDING FIRE SAFETY

Size: px
Start display at page:

Download "Occupational Health & Safety Practitioner. Reading BUILDING FIRE SAFETY"

Transcription

1 Occupational Health & Safety Practitioner Reading BUILDING FIRE SAFETY January 2009

2 Contents OVERVIEW...1 SECTION 1: INTRODUCTION...2 SECTION 2: BUILDING CLASSIFICATIONS...4 SECTION 3: PASSIVE AND ACTIVE FIRE SAFETY SYSTEMS...7 SECTION 4: BUILDING PERFORMANCE...12 SUMMARY...14 REFERENCES AND FURTHER READING...14 Government of Western Australia Department of Commerce Published by WorkSafe, PO Box 294, WEST PERTH WA Tel: Toll Free The SafetyLine Institute material has been prepared and published as part of Western Australia s contribution to national OHS skills development State of Western Australia. All rights reserved. Details of copyright conditions are published at the SafetyLine Institute website. Before using this publication note should be taken of the Disclaimer, which is published at the SafetyLine Institute website.

3 OVERVIEW This reading provides an introduction to underlying principles of fire safety including objectives of fire safety, the division of buildings into various classes relating to fire safety requirements, and passive and active fire safety systems. Objectives After reading this information you should have a basic understanding of how a multi-storey office building functions in a fire. Author Danny Spadaccini JANUARY 2009 SAFETYLINE INSTITUTE PAGE 1

4 Section 1: INTRODUCTION Glossary of terms When they are first used, glossary terms are indicated with an asterisk (*). Make sure that you are familiar with the Glossary of terms before going any further. Fire Fire Separation Fire Resistance Level (FRL) The state of combustion in which inflammable material burns, producing heat, flames and often smoke. The use of a wall, that divides a storey or building, to resist the spread of fire or smoke. The grading period given in minutes for Structural Adequacy (ability to maintain load); Integrity (ability to prevent passage of flames and hot gases); and Insulation (ability to maintain surface temperature). It is expressed as 90/90/ Fire safety of a building is important Building safety in relation to fire* has been an important social and economic factor to the human race for thousands of years. Fire provides heat to our homes and places of work; it powers, directly or indirectly, much of the machinery and appliances in factories and homes; and generally contributes to the standard of living throughout most of the modern world. PAGE 2 SAFETYLINE INSTITUTE JANUARY 2009

5 1.2 Historical perspective History shows that fire was recognised as a threat to great civilisations as early as 2000 years ago. The Roman Empire devised a system of corps vigilante whose sole task was to be on watch for the outbreak of fire. The Great Fire of London in 1666 became the catalyst for the modern day building codes. The fire broke out in a baker's shop and destroyed half of London. The buildings in London at that time were not fire separated and so the fire spread easily. Analysis of how the fire spread led to the creation of the first building regulations. 1.3 Consequences of a fire When fire is not controlled the result can be: KEY POINT Fire Separation*: the use of wall that divides a storey or building to resist the spread of fire or smoke. death and injury of people who cannot escape its smoke, gases and heat; destruction of buildings, their contents and other tangible property; temporary or permanent closure of business, loss of income and possibly bankruptcy; and destruction of irreplaceable reminders of human heritage. 1.4 Basic fire safety concepts Building fire safety takes into account: safe egress (exit) from the building for occupants; facilities for fighting fire within buildings; prevention of spread of fire to adjoining properties; and access and egress for fire fighting personnel. JANUARY 2009 SAFETYLINE INSTITUTE PAGE 3

6 Section 2: BUILDING CLASSIFICATIONS 2.1 Ten occupancy classes for buildings In Australia, the Building Codes divide buildings into the following occupancy classes: 1. Single Dwelling 2. A Building containing 2 or more sole occupancy units, each being a single dwelling. 3. A residential building, other than a building of Class 1 or 2, which is a common place of long term or transient living for a number of unrelated persons, including: boarding house, guest house, hostel, lodging house, or backpackers' accommodation; or a residential part of an hotel or motel; or a residential part of a school; or accommodation for the aged, disabled or children; or a residential part of a health care building which accommodates members of staff. 4. A dwelling in a building that is in a Class 5, 6, 7, 8, or 9 if it is the only dwelling in the building. 5. An office or building used for professional or commercial purposes excluding classes 6,7,8, and A shop or other building for the sale of goods by retail or the supply of services direct to the public, including: an eating room, cafe, restaurant, milk or soft drink bar; or a dining room, bar, shop or kiosk part of a hotel or motel; or a hairdresser's or barber's shop, public launderer, undertaker's establishment; or market or sale room, showroom, or service station. PAGE 4 SAFETYLINE INSTITUTE JANUARY 2009

7 7. A building which is: a carpark; or for storage, or display of goods or produce for sale by wholesale. 8. A laboratory, or a building in which a handicraft or process for the production, assembling, altering, repairing, packaging and/or finishing of goods or produce is carried out for trade, sale or gain. 9. A building of public nature: a health care building, including those set aside as a laboratory; or an assembly building, including a trade workshop, laboratory, or the like in a primary or secondary school, but excluding any other parts of the building that are another class. 10. A non-habitable structure: a non-habitable building being a private garage, carport, shed, or the like; or a structure being a fence, mast, antenna, retaining or free standing wall, swimming pool or the like. 2.2 Why have classifications? Characteristics of occupants The characteristics of each type of classification are linked to life safety as each of these classes has certain KEY POINT features that impact on an occupant's safe egress. Effective building fire safety must Factors relating to the take into account characteristics of the capabilities of occupants influence safe egress. persons who can be expected to occupy the building including: age and mobility; awareness of fire; knowledge of the environment; density of occupancy; and control of occupants (impact of smoke on human behaviour). JANUARY 2009 SAFETYLINE INSTITUTE PAGE 5

8 The various classes take into account the variable characteristics of occupants, thus the many differing requirements for types of building. For example, the egress capabilities of an aged care wing of a hospital would differ greatly to that of an office where most employees would be able to exit the building without any assistance. A further example of this is a primary school where the majority of occupants (children) would require direct supervision to escape as compared to a warehouse whose employees would not require the same level of supervision for egress. Characteristics of the building The Building Code also takes into account other essential issues which can affect the performance of the building, such as the construction characteristics of the building. All buildings fall into three classifications of construction, being Type A, B & C. Type A is the form of construction with the highest fire resistant requirements, while type C has the lowest. The relationship between occupancy class, type of construction, and number of storeys is illustrated by the following chart. NUMBER OF STOREYS OCCUPANCY CLASS FLAT HOTEL OFFICE SHOP WAREHOUSE FACTORY PUBLIC 4 or more A A A A A A A 3 A A B B B B A 2 B B C C C C B 1 C C C C C C C DAY/ NIGHT DAY/ NIGHT DAY TIME DAY TIME STORAGE INDUSTRIAL CARE/ ASSEMBLY In addition to the type of construction used, many other components are required by the Building Code as the building size and complexity increases. Two examples are hose-reels and emergency lighting. The requirements for hose-reels and their locations vary, being dependent on the classification and size of the building. The requirements for emergency lighting are related to the classification of the building and the amount of floor area. KEY POINT The Building Code states the construction and fire safety requirements necessary. PAGE 6 SAFETYLINE INSTITUTE JANUARY 2009

9 Section 3: PASSIVE AND ACTIVE FIRE SAFETY SYSTEMS 3.1 Passive and active systems create the fire safety package for the building The features within a building can be broken down into passive and active systems for building fire safety. Passive systems are the permanent fixtures of the building such as fire rated floors, ceilings, walls, fire-isolated exits and columns. Active systems are services and equipment such as exit signs, emergency lighting, hydrants, hose-reels, smoke control, sprinklers, smoke and heat detectors, voice alarms, and fire indicator panels. The combination of these creates the Fire Safety Package for a building. By looking at a model building an overview of the workings of the passive and active systems within the building can be made. For the purposes of this example, we will look at a class 5 (office) multi-storey building. This will illustrate the functions of the various components of the building. It is important to note at this point that the Passive and Active systems within a building can be designed in many different ways to achieve the same objectives required for the structure. A fire starts at 12.00am on the third floor at a power point under a large desk in an archives section and quickly ignites files and assorted boxes stored under the desk. The archives section is vacant from 12.00am to 1.00pm due to the lunch break of the Archives Officer. For the purposes of the exercise, the assessment will be of a building without sprinklers. JANUARY 2009 SAFETYLINE INSTITUTE PAGE 7

10 3.2 Active systems detect the fire The smoke detection system would detect the smoke plume from the fire within 2-5 minutes of the fire starting. It is important to realise that detection of fire by the building occupants' senses of sight, smell and hearing are quite often the first form of detection. With the smoke detector alarm system engaged a general alarm will be raised. Smoke detectors can be located in the return air ducts of the air conditioning or at ceiling level dispersed throughout the building. This alarm can include direct alarm to brigade as well as to the whole building. The alarm would alert Fire Wardens within the building who would stand-by at their designated phones. Photograph from Safety and Health, official publication of the National Safety Council. The Fire Warden of the Floor where the incident began would investigate the fire and if able to, start fighting the fire. If not able to control fire the warden will begin evacuation of the floor and, in conjunction with other wardens, evacuate the building if necessary. 3.3 Passive systems Fire Resistance Level Fire Resistance Level (FRL)* is the grading period given in minutes (expressed for example as 90/90/90) for: structural adequacy (ability to maintain load); integrity (ability to prevent passage of flames and hot gases); and insulation (ability to maintain surface temperature). PAGE 8 SAFETYLINE INSTITUTE JANUARY 2009

11 The building itself has now initiated alarm. This then leads onto all the fire systems within the building acting in unison. The floor upon which the fire is burning has a 120/120/120 FRL (2 hours Fire Resistance Level). This is a grading in minutes in which it would maintain its structural adequacy, integrity and insulation. Structural adequacy is the ability to maintain stability and load-bearing capacity; integrity is the ability to resist the passage of flames and gases; and insulation is the ability to maintain surface temperature. Any surrounding structural members of the building would also have similar ratings. The exit stairs would have a KEY POINT 180/120/120 rating providing safe access for occupants for a two hour period. The exit stairs Passive systems include are referred to as fire isolated which means the the fire rated floors, ceilings, walls, fire-isolated stairs have a fire resisting shaft (including walls exits and columns. and roof). The passive members of the fire systems prevent the spread of the fire to adjoining floors and allow safe egress whilst ensuring the structure does not collapse or allow the spread of smoke. 3.4 Active systems Air conditioning unit changes to exhaust mode The first detection of the fire sets a number of active systems in motion in the building. The air conditioning unit for the floor with the fire will alter its operation. The unit will go into a full exhaust mode drawing air from the floor. All other floors in the building will change to full return air mode. This ensures that a negative air pressure is maintained on the floor with the fire, drawing smoke out, and a positive air pressure is maintained on all other floors preventing the penetration of smoke. Depending on the design configuration chosen for the building stairwell, pressurisation may commence (see illustration below). Air is forced into the stairwell, creating a positive pressure, and preventing the penetration of smoke into the escape stairs. JANUARY 2009 SAFETYLINE INSTITUTE PAGE 9

12 Emergency lighting and exit signs At this stage emergency lighting and exit signs provide sufficient illumination for safe evacuation of the building. The exit signs include directional signs indicating the path to exits for occupants. The lift system cannot be used for escape in a fire and a warning sign is displayed stating so for all occupants. The fire brigade only can override the lifts for use in access for the fighting of the fire and for the purpose of evacuating people with disabilities. Fire fighting equipment Facilities installed for the fire brigade to assist in the fighting of the fire include fire hydrants, hose-reels, extinguishers and the lift as a stretcher evacuation facility if designated as such. KEY POINT Active systems include the exit signs, emergency lighting, hydrants and hose-reels, smoke detectors and sprinklers. 3.5 Event lines The following event lines provide an insight into the sequence in which various events occur within the building. PAGE 10 SAFETYLINE INSTITUTE JANUARY 2009

13 The first Event line illustrates the relationship between the development of a building fire, the progressive reduction of tenability and ability of occupants to escape. The second Event line illustrates the relationship between: the Fire; the Passive systems; the Active systems; and the People (occupant movement), and the sequence of events. JANUARY 2009 SAFETYLINE INSTITUTE PAGE 11

14 Section 4: BUILDING PERFORMANCE The Passive and Active systems within an office building can easily be disrupted and rendered inoperative by the occupants of the building. 4.1 Safe egress may be compromised Safe egress from a building is essential. This can be compromised by the following. Wedging open of exit doors to fire isolated stairs for floor to floor access. This greatly reduces the FRL (Fire Resistance Level) of the stair and also eliminates the function of stairwell pressurisation. The open door can allow smoke and flame penetration to the exit, eliminating its use for the floors above. Removal of fire door / exit door signs during maintenance such as painting. Occupants who may be unfamiliar with the building will not be able to locate exit doors. Storage of items in exit passages and stairs. The width of exit passages and stairs must not be used for storage. The path of travel to, in and from an exit should be free of obstructions at all times. Flammable objects such as cleaning fluids stored at the base of a stairwell can render an escape stair inoperative in an emergency. Desks, bookshelves and other objects can block a path of travel to an exit. Locking of exit doors for security purposes. Many office buildings have card access, which is connected to the alarm system and will not allow re-entry from an exit in an emergency. Once an escape stair has been entered in an emergency you should only be able to exit at final discharge point. No exit door should be locked at any time. The ramifications of this are occupants trapped in an exit unable to escape. Installations in fire-isolated exits. A fire-isolated exit must be maintained as its name suggests. Care must be taken to maintain the isolation of the exit. For example, carpet should not be a laid in such an exit. Discharge from exits. Exits must discharge to open space. An open space must not be a locked compound. The discharge point must not trap the occupants escaping. PAGE 12 SAFETYLINE INSTITUTE JANUARY 2009

15 4.2 Smoke control Internal partitioning and alterations do not always require approval from a Local Authority. The alteration to a floor plan in terms of high level partitioning affects the performance of air-conditioning units and smoke control. It is essential when major alterations are carried out that the design of the air-conditioning / smoke control be assessed, to ensure the original performance criteria are met. Plastic sheets cannot be taped over ducts as this alters the performance of air-conditioning. 4.3 Smoke detectors Partitioning and alterations can alter the function of detectors located at ceiling level. When partitioning is altered, the relative position of detectors may be changed so that spacings are not even or positions are not central within rooms, affecting the performance of detectors. 4.4 Emergency lighting and exit signs Partitioning and high level shelving can affect the effectiveness of emergency lighting and exit signs. Exit signs can be blocked from view and the level of illumination for the emergency lighting reduced below standard. 4.5 Hydrants, hose-reels and fire extinguishers Fire fighting equipment must be accessible at all times. The positioning of desks or shelving preventing access to fire fighting equipment must be prevented at all times. External access to hydrants for the fire brigade must be maintained in case of an emergency. JANUARY 2009 SAFETYLINE INSTITUTE PAGE 13

16 4.6 Fire rated structural components To maintain the Fire Rated Level (FRL) designed in a structural component, any alteration to it must be assessed. For example, additional penetrations to floors can allow spread of flame and gases. 4.7 Maintenance Safety installations in buildings must be adequately maintained to ensure their design performance. SUMMARY Building fire safety is an issue that must be addressed by all persons in the workplace. The fire systems in a building can be easily affected by the occupants and managers of the building. It is essential that persons who use a building understand the fire safety aspects of the building. By completing this reading you should have a basic understanding of how a building functions in a fire. These principles can be applied to your work place. Your feedback WorkSafe is committed to continuous improvement. If you take the time to complete the online Feedback Form at the SafetyLine Institute website you will assist us to maintain and improve our high standards. REFERENCES AND FURTHER READING Building Code of Australia PAGE 14 SAFETYLINE INSTITUTE JANUARY 2009

Fire Management Guide

Fire Management Guide Fire Management Guide Meeting day to day fire management obligations in WA requires reference to Health and Safety legislation, the Building Code of Australia, and multiple Australian Standards. This guide

More information

What you need to know about. Maintaining essential safety measures in your building

What you need to know about. Maintaining essential safety measures in your building What you need to know about Maintaining essential safety measures in your building When the construction of a building is complete, the building owner is responsible for its upkeep and maintenance, particularly

More information

SCHEDULE. Essential Safety Measures taken from Schedule 9 of the Building Regulations PART 1 BUILDING FIRE INTEGRITY

SCHEDULE. Essential Safety Measures taken from Schedule 9 of the Building Regulations PART 1 BUILDING FIRE INTEGRITY SCHEDULE Essential s taken from Schedule 9 of the Building Regulations 2006 43 PART 1 BUILDING FIRE INTEGRITY 1 Building elements required to satisfy prescribed fire-resistance levels 2 Materials and assemblies

More information

1970s building housing main school reception and support offices. Well managed buildings with no significant risk of a fire occurring.

1970s building housing main school reception and support offices. Well managed buildings with no significant risk of a fire occurring. Record of significant findings Risk assessment for : Assessment undertaken by : 71a The Close Nigel Billing CMIOSH Date: 21/3/17 Overview of Premises: 1970s building housing main school reception and support

More information

Well managed building mean risk is normal. Fire action notices should be displayed by all alarm break glass call points.

Well managed building mean risk is normal. Fire action notices should be displayed by all alarm break glass call points. Record of significant findings Risk assessment for : Assessment undertaken by : Horsefair House Nigel Billing CMIOSH Date: 28/3/17 Overview of Premises: 2 buildings on 3 stories in an L shaped configuration,

More information

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

First Aspen Federal Regulation Set: K LSC 2000 Health Existing First Aspen Federal Regulation Set: K 01.01 LSC 2000 Health Existing K 0000 Title CFR Type INITIAL COMMENTS Memo K 0011 If the building has a common wall with a nonconforming building, the common wall

More information

Fire Risk Assessment

Fire Risk Assessment Fire Risk Assessment Premises Description Address Area Post Code Tel no. Num of Employees Normal Occupancy Max Allowed Use of Premises Building Length Building Breadth Area 0.00 M² Floors Storeys Below

More information

Use this guide to assist you when completing the Evacuation scheme application form.

Use this guide to assist you when completing the Evacuation scheme application form. Guide EVACUATION SCHEME APPLICATION ABOUT THIS GUIDE Use this guide to assist you when completing the Evacuation scheme application form. CONTENTS Before you start completing your application Section 1

More information

SCALES NW EMERGENCY ACTION PLAN

SCALES NW EMERGENCY ACTION PLAN Purpose Each SCALES NW, INC location shall have a written Emergency Action Plan, appropriate to the hazards of the workplace, in order to respond to an emergency that may require rescue or evacuation.

More information

Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection

Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection Introduction Fires and explosions kill more than 200 and injure more than 5,000 workers each year There is a long and tragic

More information

Certification Assessment Instrument and Guidelines

Certification Assessment Instrument and Guidelines Certification Instrument Full compliance with BCA 96 will ensure passing 19 for Section 1 Do not need 100 to pass 1 SECTION 1 SAFETY (25 POINTS) Residential Fire Sprinkler System Not required to pass Section

More information

EMERGENCY EVACUATION PLAN for FIRE

EMERGENCY EVACUATION PLAN for FIRE St.Thomas More s Catholic Primary School EMERGENCY EVACUATION PLAN for FIRE This plan provides guidance and information for the occupants of St Thomas More's Catholic School and the Emergency Control Organisation

More information

161 Rosebery Avenue, London, EC1 Fire Safety Management Plan & Evacuation Procedures

161 Rosebery Avenue, London, EC1 Fire Safety Management Plan & Evacuation Procedures 161 Rosebery Avenue, London, EC1 Fire Safety Management Plan & Evacuation Procedures Contents 1.0 Introduction 2.0 Means of Escape in Case of Fire 3.0 Means for Giving Warning in Case of Fire 4.0 Means

More information

High Rise Floor Wardens

High Rise Floor Wardens Fire Safety Teaching Guide High Rise Floor Wardens Seattle Fire Department Fire Prevention Division Floor Warden Training Instructor Outline Introduction Goals: To ensure that high rise floor wardens are

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 51 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS CFR Type Memo Tag FED - K0130 - MISCELLANEOUS Title MISCELLANEOUS OTHER LSC DEFICIENCY NOT ON 2786 FED - K9999 - FINAL OBSERVATIONS Title

More information

Demolition Permit Application (Please print and complete ENTIRE form)

Demolition Permit Application (Please print and complete ENTIRE form) Office Use Only Submission Date: Received By: Folder Number: Demolition Permit Application (Please print and complete ENTIRE form) DEMOLITION SITE INFORMATION Address of Demolition: Zoning: Type of Building

More information

Project: Location: Date Prepared: Last Reviewed:

Project: Location: Date Prepared: Last Reviewed: Project: Location: Date Prepared: Last Reviewed: Contents Premises Essential Information 4 Definitions & Acronyms 5 Introduction 5 Building Description and Safety Systems 7 General Strategy, Responsibilities

More information

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE FIRE RISK ASSESSMENT HORSEFAIR HOUSE BUILDING SUMMARY The building is utilised for the teaching of Science and contains Laboratories and Chemical storage. 1. Identification of the hazards 1.1 Identification

More information

UCL PRINCIPAL CONTRACTOR SITE FIRE SAFETY RISK REVIEW & MITIGATION MEASURES

UCL PRINCIPAL CONTRACTOR SITE FIRE SAFETY RISK REVIEW & MITIGATION MEASURES Mandatory Fire Safety Instruction UCL PRINCIPAL CONTRACTOR SITE FIRE SAFETY RISK REVIEW & MITIGATION MEASURES Principal Contractor fire safety considerations in shared occupancy project or refurbishments

More information

FIRE SAFETY PLAN FIRST & JASPER JASPER AVENUE

FIRE SAFETY PLAN FIRST & JASPER JASPER AVENUE FIRE SAFETY PLAN FIRST & JASPER 10065 JASPER AVENUE March 2014 Fire/Emergency Evacuation Procedures Introduction GWL Realty Advisors is the property management company responsible for the building located

More information

SURREY FIRE SERVICE. Construction Fire Safety Plan Bulletin

SURREY FIRE SERVICE. Construction Fire Safety Plan Bulletin SURREY FIRE SERVICE Construction Fire Safety Plan Bulletin The B.C. Fire Code requires building owners/contractors to comply with the requirements of the BC Fire Code 5.6 Construction and Demolition Sites

More information

University of Maryland FIRE EVACUATION PLAN

University of Maryland FIRE EVACUATION PLAN University of Maryland FIRE EVACUATION PLAN PLAZA PARKING GARAGE POLICE - 711 FIRE - 711 MEDICAL EMERGENCY - 711 Anyone discovering excessive heat, smoke, or fire inside your building will immediately

More information

Outline of Measures for Fire Prevention and Safety under the Laws and Regulations of Fire Fighting

Outline of Measures for Fire Prevention and Safety under the Laws and Regulations of Fire Fighting Outline of Measures for Fire Prevention and Safety under the Laws and Regulations of Fire Fighting Materials created by the Fire and Disaster Management Agency were translated by the International Fire

More information

8.1. Fire and Heritage. The maintenance series. Information sheet. Guidelines on Fire Safety in Heritage Buildings

8.1. Fire and Heritage. The maintenance series. Information sheet. Guidelines on Fire Safety in Heritage Buildings The maintenance series Information sheet 8.1 Fire and Heritage Destruction of the Prince of Wales Theatre by fire on 3 October 1860. It was situated at the corner of King and Castlereagh Streets, Sydney.

More information

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge. 2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge. Exception: Manual fire alarm boxes are not required where the building is

More information

Fire Safety Protocol

Fire Safety Protocol CORPORATE HEALTH AND SAFETY POLICY: Part 3 Arrangements Fire Safety Protocol Document Status: [ ] Guidance for Managers [] Protocol [ ] Procedures Version 0.1/ August 2013 DRAFT EALING NCIL Table of Contents

More information

FIRE & EVACUATION PLAN PARADISE LOST

FIRE & EVACUATION PLAN PARADISE LOST FIRE & EVACUATION PLAN PARADISE LOST For High Occupancy Buildings Note: 1) This Fire and Evacuation Plan is intended to provide compliance with the Building Fire Safety Regulations 2008 and does not necessarily

More information

FIRE EVACUATION PLAN PRATT STREET PARKING GARAGE AND ATHLETIC CENTER POLICE FIRE MEDICAL EMERGENCY

FIRE EVACUATION PLAN PRATT STREET PARKING GARAGE AND ATHLETIC CENTER POLICE FIRE MEDICAL EMERGENCY University of Maryland FIRE EVACUATION PLAN PRATT STREET PARKING GARAGE AND ATHLETIC CENTER POLICE - 711 FIRE - 711 MEDICAL EMERGENCY - 711 Anyone discovering excessive heat, smoke, or fire inside your

More information

Charlotte Building, 17 Gresse Street, London W1T 1QL

Charlotte Building, 17 Gresse Street, London W1T 1QL Charlotte Building, 17 Gresse Street, London W1T 1QL Fire Safety Management & Evacuation Procedures Contents 1.0 Introduction 2.0 Means of Escape in Case of Fire 3.0 Means for Giving Warning in Case of

More information

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT Factory Name: 4 YOU CLOTHING LTD 367/1 Senpara Parbata, Mirpur-10, Dhaka Dhaka Dhaka Bangladesh 27 May 2014 The Alliance for Bangladesh Worker Safety Page 1/20

More information

TEN STEP PROCESS PREPARING FIRE SAFETY PLANS

TEN STEP PROCESS PREPARING FIRE SAFETY PLANS TEN STEP PROCESS PREPARING FIRE SAFETY PLANS STEP 1 CONDUCT FIRE SAFETY AUDIT IDENTIFY BUILDING FEATURES AND HUMAN RESOURCES. STEP 2 APPOINTMENT OF SUPERVISORY STAFF IDENTIFY TRAINED SUPERVISORY STAFF

More information

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT Factory Plot # 33-36 Sector # 07, Chittagong Chittagong Chittagong 08 Jun 2014 The Alliance for Worker Safety Page 1/18 08 Jun 2014 Introduction to the Report

More information

Building Fire Safety in New York City s Existing Office Buildings

Building Fire Safety in New York City s Existing Office Buildings www.goldmancopeland.com Building Fire Safety in New York City s Existing Office Buildings Daniel Colombini, PE, LEED AP Principal, Director of Plumbing/Fire Protection Director of Plumbing and Fire Protection

More information

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14 Fire Prevention Program Purpose The Company Fire Safety Plan has been developed to work in conjunction with company emergency plans and other safety programs. This includes reviewing all new building construction

More information

Fire Safety Audit: Part B - Questionnaire (Questionnaire Devised By Mr.R.R.Nair) Yes No x

Fire Safety Audit: Part B - Questionnaire (Questionnaire Devised By Mr.R.R.Nair) Yes No x Fire Safety Audit: Part B - Questionnaire (Questionnaire Devised By Mr.R.R.Nair) Yes No x Name & Address of the Society IDENTIFY PEOPLE AT RISK 01 Have you identified who is at risk? 02 Have you identified

More information

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE FIRE RISK ASSESSMENT SPORTS CENTRE BUILDING SUMMARY The building is used as a Sports Centre and contains a large sports hall with changing rooms, an office for staff and a fitness area. 1. Identification

More information

MAINTENANCE OF ESSENTIAL SAFETY MEASURES EXPLAINED (Building Regulations 2006)

MAINTENANCE OF ESSENTIAL SAFETY MEASURES EXPLAINED (Building Regulations 2006) MAINTENANCE OF ESSENTIAL SAFETY MEASURES EXPLAINED (Building Regulations 2006) 1. INTRODUCTION 1.1 Essential Safety Measures Defined Essential Safety Measures (previously called essential services) are

More information

Fire Evacuation Plan Bressler Research Building. UMB POLICE or

Fire Evacuation Plan Bressler Research Building. UMB POLICE or UMB POLICE - 711 or 410-706-3333 If you discover fire, smoke, or excessive heat inside your building, immediately: 1. Activate fire alarm by pulling manual fire alarm pull station (located near exits)

More information

Steven Craft, PhD, P.Eng. FIRE SAFETY DURING THE COURSE OF CONSTRUCTION

Steven Craft, PhD, P.Eng. FIRE SAFETY DURING THE COURSE OF CONSTRUCTION Steven Craft, PhD, P.Eng. FIRE SAFETY DURING THE COURSE OF CONSTRUCTION Mid-Rise Workshop, Coast Plaza Inn, Calgary, Feb. 4 th, 2016 Outline Overview of risks Regulations Changes to 2015 NFC for mid-rise

More information

FP-PGN-14 Part of NTW(O)41 Fire Policy

FP-PGN-14 Part of NTW(O)41 Fire Policy Fire Policy Practice Guidance Note Fire Evacuation in Trust Owned and Occupied Premises V02 Date Issued Issue 1 Aug 2017 Planned Review Aug - 2020 Responsible Officer Head of Estates & Facilities (NTW

More information

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY)

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY) FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY) BUILDING SUMMARY The building was constructed in Victorian times and is constructed of brick with knapped flint in fill on some outer walls. The building

More information

Chapter Nursing Homes

Chapter Nursing Homes Chapter 16.01 Nursing Homes Section 1. Licensing. No nursing, convalescent or old age home, as defined in Section 2 of this ordinance, shall be operated except under a license from the City Council of

More information

FIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY

FIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY FIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY PLAN REVIEWS SITE PLANS: 1) Access to buildings (Volume V NC Building Code sections 602.6.1

More information

Fire protection documentation. CFPA-E Guideline No 13:2015 F

Fire protection documentation. CFPA-E Guideline No 13:2015 F Fire protection documentation CFPA-E Guideline No 13:2015 F FOREWORD The European fire protection associations have decided to produce common guidelines in order to achieve similar interpretation in the

More information

FIRE SAFETY PLAN FOR CONSTRUCTION, RENOVATION AND DEMOLITION SITES

FIRE SAFETY PLAN FOR CONSTRUCTION, RENOVATION AND DEMOLITION SITES BACKGROUND INFORMATION Alberta Fire Code 2014: FIRE SAFETY PLAN FOR CONSTRUCTION, RENOVATION AND DEMOLITION SITES Alberta Fire Code (AFC) 2014, Division B, Section 5.6. requires a Fire Safety Plan for

More information

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS FIRE RISK ASSESSMENT NEW BUILDINGS BUILDING SUMMARY The building is utilised for classroom teaching for Modern Languages. 1. Identification of the hazards 1.1 Identification of sources of fuel. Timber

More information

F.R.A.M.E. EVENT NETWORKS used in "FRAME".

F.R.A.M.E. EVENT NETWORKS used in FRAME. EVENT NETWORKS used in "FRAME". In 2004, Dipl. Ing. Trond Maag wrote his doctorates' thesis "Risikobasierte Beurteilung der Personensicherheit von Wohnbauten im Brandfall unter Verwendung von Bayes'schen

More information

Unit 2 Fire Safety (Zone 1)

Unit 2 Fire Safety (Zone 1) IFE Level 3 Diploma in Fire Safety and Fire Science Unit 2 Fire Safety (Zone 1) Examiner Report March 2018 Introduction 42% of candidates attained a Pass. Half of the candidates that attained a Pass secured

More information

INITIAL FIRE ASSESSMENT REPORT (FAR)

INITIAL FIRE ASSESSMENT REPORT (FAR) INITIAL FIRE ASSESSMENT REPORT (FAR) Factory SQ Station, Plot # 221-223, Jamirdia, Valuka, Mymensingh Mymensingh 17 Jun 2014 The Alliance for Bangladesh Worker Safety Page 1/17 Factory 17 Jun 2014 Introduction

More information

Purpose of Emergency Response Program Emergency Response Team / Leader Evacuation Procedures Building Life Safety System Virtual Evacuation Building

Purpose of Emergency Response Program Emergency Response Team / Leader Evacuation Procedures Building Life Safety System Virtual Evacuation Building Purpose of Emergency Response Program Emergency Response Team / Leader Evacuation Procedures Building Life Safety System Virtual Evacuation Building Tour Questions and Answers To prepare designated office

More information

Fire Safety Management Plan. Qube 90, Whitfield Street, W1T 4EZ. Fire Safety Management Plan & Evacuation Procedures

Fire Safety Management Plan. Qube 90, Whitfield Street, W1T 4EZ. Fire Safety Management Plan & Evacuation Procedures Fire Safety Management Plan & Evacuation Procedures Contents 1.0 Introduction 2.0 Means of Escape in Case of Fire 3.0 Means for Giving Warning in Case of Fire 4.0 Means for Fighting Fire 5. 0 Discovering

More information

Date and Time of Incident. Feb. 13, 1964 Breakout at15:33 (approx.) Noticed at 15:27 Notified by emergency call. Extinguished by 21:07

Date and Time of Incident. Feb. 13, 1964 Breakout at15:33 (approx.) Noticed at 15:27 Notified by emergency call. Extinguished by 21:07 Building Name Address Matsuya Ginza Department Store 3-1 Ginza, Chuo-ku, TOKYO I. Summary of Fire Incident Use (as per FSA Annexed Table 1) Department Store (4) Date and Time of Incident Feb. 13, 1964

More information

Guidelines for Fire Safety Plans at Construction or Demolition Sites

Guidelines for Fire Safety Plans at Construction or Demolition Sites Guidelines for Fire Safety Plans at Construction or Demolition Sites Sun Peaks Fire Rescue P.O. Box 1000, Sun Peaks, V0E 5N0 Phone 250-578-8985 Fax 250-578-8905 Guidelines for Fire Safety Plans at Construction

More information

Unit 2 Fire Safety (Zone 2)

Unit 2 Fire Safety (Zone 2) IFE Level 3 Diploma in Fire Safety and Fire Science Unit 2 Fire Safety (Zone 2) Examiner Report March 2017 Introduction 21% of the candidates that sat the examination attained a pass. Candidates did not

More information

Sandwell Valley School and Sandwell Community Care Trust Training. 150 Birmingham Road, West Bromwich, B70 6QT

Sandwell Valley School and Sandwell Community Care Trust Training. 150 Birmingham Road, West Bromwich, B70 6QT Fire Risk Assessment Company ame Address of premises (premises being assessed) Sandwell Valley School and Sandwell Community Care Trust Training 150 Birmingham Road, West Bromwich, B70 6QT ame of Responsible

More information

Fire Risk Assessment (FRA) Checklist

Fire Risk Assessment (FRA) Checklist Fire Risk Assessment (FRA) Checklist Assessed by: Job Title: Department/Location: Date Document Downloaded: Date of Assessment: Duty Holder Name: FRA. Description / Comments FHRA. 1. MANAGEMENT, PLANNING

More information

The Social Accountability International (SAI) Fire Safety Checklist

The Social Accountability International (SAI) Fire Safety Checklist The Social Accountability International (SAI) Fire Safety Checklist Introduction The Social Accountability International (SAI) Fire Safety Checklist is a guidance tool prepared for SA8000 & BSCI Auditors

More information

University of Maryland FIRE EVACUATION PLAN NATIONAL DENTAL MUSEUM POLICE FIRE MEDICAL EMERGENCY Anyone discovering excessive heat,

University of Maryland FIRE EVACUATION PLAN NATIONAL DENTAL MUSEUM POLICE FIRE MEDICAL EMERGENCY Anyone discovering excessive heat, University of Maryland FIRE EVACUATION PLAN NATIONAL DENTAL MUSEUM POLICE - 711 FIRE - 711 MEDICAL EMERGENCY - 711 Anyone discovering excessive heat, smoke, or fire inside your building will immediately

More information

MOIEZ AHMED Chief Fire Warden Director Training - Usha Armour Pvt. Ltd., Bangalore. Fire Drill (Fire Evacuation Drill Procedure)

MOIEZ AHMED Chief Fire Warden Director Training - Usha Armour Pvt. Ltd., Bangalore. Fire Drill (Fire Evacuation Drill Procedure) MOIEZ AHMED Chief Fire Warden Director Training - Usha Armour Pvt. Ltd., Bangalore 1. Introduction Fire Drill (Fire Evacuation Drill Procedure) The aim of this paper is to give a general understanding

More information

Fire Protection. A Health and Safety Guideline for Your Workplace. Introduction. Fire Prevention and Control. Workplace Assessment

Fire Protection. A Health and Safety Guideline for Your Workplace. Introduction. Fire Prevention and Control. Workplace Assessment A Health and Safety Guideline for Your Workplace Fire Protection Introduction Fire Protection is an organized approach designed to prevent fires. In the event of a fire, a fire protection program will

More information

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130)

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130) MANDATORY MEASURES INDOOR LIGHTING CONTROLS (Reference: Sub-Chapter 4, Section 130) MANDATORY LIGHTING CONTROLS 1. Area Controls: Manual controls that control lighting in each area separately 2. Multi-level

More information

Fire Safety Risk Assessment for Treowen, Wonastow, Monmouth, NP25 4DL

Fire Safety Risk Assessment for Treowen, Wonastow, Monmouth, NP25 4DL Fire Safety Risk Assessment for Treowen, Wonastow, Monmouth, NP25 4DL Record of significant findings Scope of Risk Assessment This fire safety risk assessment covers the use of Treowen as a venue for Civil

More information

Renovation Program. Renovation Program GENERAL

Renovation Program. Renovation Program GENERAL Renovation Program GENERAL This program provides guidance and protocols for renovation projects in occupied, operational acute hospitals. Team building is essential to quality control and HFD Services

More information

Interim Amendments to Ontario s 2012 Building Code Retirement Homes. August 17, 2017

Interim Amendments to Ontario s 2012 Building Code Retirement Homes. August 17, 2017 Interim Amendments to Ontario s 2012 Building Code Retirement Homes August 17, 2017 Notice This presentation is intended for general information purposes only. It is not intended as legal or technical

More information

FIRE SAFETY AND PREVENTION POLICY

FIRE SAFETY AND PREVENTION POLICY Effective Date: July 26, 2011 Supersedes /Amends: VRS-49/April 2006 Originating Office: Office of the Vice-President, Services Policy Number: VPS-49 PREAMBLE Concordia University (the University ) has

More information

FIRE SAFETY AND EVACUATION PLANNING FOR ASSISTED LIVING FACILITIES AND NURSING HOMES

FIRE SAFETY AND EVACUATION PLANNING FOR ASSISTED LIVING FACILITIES AND NURSING HOMES FIRE SAFETY AND EVACUATION PLANNING FOR ASSISTED LIVING FACILITIES AND NURSING HOMES West Metro Fire Rescue Life Safety Division 433 South Allison Parkway Lakewood, Colorado 80226 (303) 989-4307 Fax (303)

More information

Fire Protection Coffee Break Training May 2016

Fire Protection Coffee Break Training May 2016 Fire Protection Coffee Break Training May 2016 Introduction High-Rise Requirements Questions and Answers Agenda Overview Site Fire Access Aerial Access Power/Back-up Power Elevators and Access Sprinklers

More information

Fire Safety Workbook

Fire Safety Workbook Fire Safety Workbook For All Staff Please ensure you read the workbook thoroughly and complete the assessment at the end Version: 1. Introduction This workbook offers a flexible way in which the basic

More information

NYU RESIDENTIAL FIRE SAFETY PLAN PART I - BUILDING INFORMATION SECTION

NYU RESIDENTIAL FIRE SAFETY PLAN PART I - BUILDING INFORMATION SECTION BUILDING ADDRESS: BUILDING OWNER: Name: Address: Telephone : NYU RESIDENTIAL FIRE SAFETY PLAN PART I - BUILDING INFORMATION SECTION Greenberg Hall 545 First Avenue, NY, NY, 10016 New York University 70

More information

University of Maryland FIRE EVACUATION PLAN Columbus Center POLICE FIRE MEDICAL EMERGENCY - 911

University of Maryland FIRE EVACUATION PLAN Columbus Center POLICE FIRE MEDICAL EMERGENCY - 911 University of Maryland FIRE EVACUATION PLAN Columbus Center POLICE - 911 FIRE - 911 MEDICAL EMERGENCY - 911 Anyone discovering excessive heat, smoke, or fire will immediately sound an alarm and report

More information

Fire Risk Assessment Safety Checklist

Fire Risk Assessment Safety Checklist Fire Risk Assessment Safety Checklist This checklist has been prepared to help you comply with The Regulatory Reform Fire Safety Order 2005 What is the Regulatory Reform (Fire Safety) Order 2005? The Regulatory

More information

Fire Evacuation Plan Health Sciences & Human Services Library. UMB POLICE or

Fire Evacuation Plan Health Sciences & Human Services Library. UMB POLICE or UMB POLICE - 711 or 410-706-3333 If you discover fire, smoke, or excessive heat inside your building, immediately: 1. Activate fire alarm by pulling manual fire alarm pull station (located near exits)

More information

Date and Time of Incident. March 10, 1975

Date and Time of Incident. March 10, 1975 Building Name Address Sennari Hostel 1-8-20 Oginochaya, Nishinari-ku, Osaka City, OSAKA Use (as per FSA Annexed Table 1) Hostel (5) a Date and Time of Incident March 10, 1975 Breakout at 06:16 (approx)

More information

TABLE OF CONTENTS Part 6 Legal Basis for Fire Safety Planning... 2

TABLE OF CONTENTS Part 6 Legal Basis for Fire Safety Planning... 2 TABLE OF CONTENTS Part 6 Legal Basis for Fire Safety Planning... 2 6.1] GENERAL... 2 6.2] EXCERPTS FROM 2012 BC FIRE CODE PART 2 BUILDING AND OCCUPANT FIRE SAFETY... 3 6.3] EXCERPTS FROM 2012 BC FIRE CODE

More information

Fire Evacuation Plan Davidge Hall. UMB POLICE or

Fire Evacuation Plan Davidge Hall. UMB POLICE or UMB POLICE - 711 or 410-706-3333 If you discover fire, smoke, or excessive heat inside your building, immediately: 1. Activate fire alarm by pulling manual fire alarm pull station (located near exits)

More information

Emergency Evacuation Plan. Tiffany Tower Plot W2 Jumeirah Lakes Towers

Emergency Evacuation Plan. Tiffany Tower Plot W2 Jumeirah Lakes Towers Emergency Evacuation Plan Tiffany Tower Plot W2 Jumeirah Lakes Towers September 2017 TABLE OF CONTENTS 1.0 I N T R O D U C T I O N... 1 2.0 B U I L D I N G I N F O R M A T I O N... 1 3.0 F I R E S Y S

More information

EMERGENCY EVACUATION POLICY FOR 100 CHEROKEE STREET BUILDING

EMERGENCY EVACUATION POLICY FOR 100 CHEROKEE STREET BUILDING EMERGENCY EVACUATION POLICY FOR 100 CHEROKEE STREET BUILDING In the event of a fire or other emergency, seconds count. The safe, orderly and prompt evacuation of building occupants depends on having the

More information

Mulch fires, trash can fires, or other fire outside a building should be reported by the following methods:

Mulch fires, trash can fires, or other fire outside a building should be reported by the following methods: University of Maryland FIRE EVACUATION PLAN HEALTH SCIENCE FACILITY I (HSF I) POLICE - 711 FIRE - 711 MEDICAL EMERGENCY - 711 Anyone discovering excessive heat, smoke, or fire inside your building will

More information

Firefighting operations on automatic sprinklers systems F5-06 GD

Firefighting operations on automatic sprinklers systems F5-06 GD DESIGNER S GUIDE Firefighting operations on automatic sprinklers systems F5-06 GD Introduction When to use Scope Use this chapter to provide a consistent Fire and Emergency New Zealand position on design

More information

Interim Life Safety Measures. Healthcare Construction Certificate - Level 1

Interim Life Safety Measures. Healthcare Construction Certificate - Level 1 Interim Life Safety Measures Purpose of Interim Life Safety Management BASIC SAFETY: During renovations projects in healthcare occupancies, the basic level of protection for the occupants must be maintained

More information

The Swedish National Board of Housing, Building and Planning s general recommendations on the analytical design of a building s fire protection, BBRAD

The Swedish National Board of Housing, Building and Planning s general recommendations on the analytical design of a building s fire protection, BBRAD The Swedish National Board of Housing, Building and Planning s general recommendations on the analytical design of a building s fire protection, BBRAD BFS 2011:27 with amendments up to BFS 2013:12 The

More information

2010 Fire Log Fire Log. Annual Fire Safety Report

2010 Fire Log Fire Log. Annual Fire Safety Report Annual Fire Safety Report The Higher Education Opportunity Act became law in August 2008 and requires all United States academic institutions to produce an annual fire safety report outlining fire safety

More information

Fire Safety Plan (FSP) Review Checklist 1

Fire Safety Plan (FSP) Review Checklist 1 Fire Safety Plan (FSP) Review Checklist 1 (Component of a BC Fire Code (BCFC) compliance inspection) COMPANY INFORMATION Company name: Building Name: Address: Street # and name City/Province Postal Code

More information

Fire Safety Plan Information. For Construction and Demolition Sites

Fire Safety Plan Information. For Construction and Demolition Sites Fire Safety Plan Information For Construction and Demolition Sites FIRE CODE INTERPRETATION November 2009 FCI-09-03 Page 1 of 8 ISSUE: FIRE SAFETY PLAN Construction and Demolition Sites Safety provisions

More information

Fire Safety Plan (FSP) Review Checklist 1

Fire Safety Plan (FSP) Review Checklist 1 Fire Inspection & Prevention Initiative Fire Safety Plan (FSP) Review Checklist 1 (Component of a BC Fire Code (BCFC) compliance inspection) Date: COMPANY INFORMATION Company Name: Building Name: Address:

More information

S12 Fire Safety Risk Assessment H&SFS01-1 / 9

S12 Fire Safety Risk Assessment H&SFS01-1 / 9 S12 Fire Safety Risk Assessment H&SFS01 Risk ratings The following risk ratings are based on two factors: The overall fire risk rating for the site The risk rating for the individual recommendations /control

More information

RAMBLER PARK FIRE SAFETY INFORMATION

RAMBLER PARK FIRE SAFETY INFORMATION RAMBLER PARK FIRE SAFETY INFORMATION Parmenter Realty Partners 7557 Rambler Rd. Dallas, Texas 75231 214-373-9561 214-373-9620 (fax) RAMBLER PARK RAMBLER PARK FIRE SAFETY INFORMATION II. Objective To provide

More information

Fire safety systems. Behaviour of fires

Fire safety systems. Behaviour of fires Fire safety systems The objective of the BCA Housing Provisions (Volume 2) with respect to Class 1 buildings (residential) and fire, is to safeguard occupants from illness or injury, to avoid the spread

More information

GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT

GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT BUILDING ASSESSMENT REPORT FIRE FOR 75 Fox Street Building OCTOBER 2014 Report for Department of Infrastructure Development Fire Services Preliminary Report:

More information

DEALING WITH FIRE SAFETY

DEALING WITH FIRE SAFETY DEALING WITH FIRE SAFETY Personal Care Homes And Assisted Living Facilities Presented by: Harold D. Hicks, P.E., FSFPE Fire Protection Engineer 1 Atlantic Code Consultants 2 Our Objectives Recognize the

More information

2012 B.C. Building Code Compliance Review (Division B Part 3)

2012 B.C. Building Code Compliance Review (Division B Part 3) Planning and Building Department 2012 B.C. Building Code Compliance Review PROJECT NAME:.. CIVIC ADDRESS:...... PERMIT APPLICATION NO.:. DATE:... I,, have: 1. reviewed the design, plans and supporting

More information

FIRE SAFETY MANAGEMENT PLANS DEVELOPMENT GUIDE A GUIDE TO DEVELOPING

FIRE SAFETY MANAGEMENT PLANS DEVELOPMENT GUIDE A GUIDE TO DEVELOPING FIRE FETY MANAGEMENT PLANS DEVOPMENT GUIDE A GUIDE TO DEVOPING FIRE FETY MANAGEMENT PLANS EXAMPLE FIRE FETY MANAGEMENT PLAN This example of a Fire Safety Management Plan does not relate to an actual building

More information

Life Safety and Professional Standards Bureau

Life Safety and Professional Standards Bureau Life Safety and Professional Standards Bureau September 26, 2011 1 The purpose of the briefing is to provide an overview of the Life Safety and Professional Standards Bureau to highlight: Organization

More information

FIRE PREVENTION The Gory Story

FIRE PREVENTION The Gory Story ERI Safety Videos Videos for Safety Meetings 2133 FIRE PREVENTION The Gory Story Leader s Guide 2001, ERI PRODUCTIONS FIRE PREVENTION: The Gory Story This easy-to-use Leader s Guide is provided to assist

More information

1303 Trans Canada Way SE Medicine Hat, AB T1B 3Z9 Phone

1303 Trans Canada Way SE Medicine Hat, AB T1B 3Z9 Phone Medicine Hat Fire Service Construction Site Fire Safety Plan ABC Part 9 Buildings 1303 Trans Canada Way SE Medicine Hat, AB T1B 3Z9 Phone 403-529-8282 Email fireprevention@medicinehat.ca Small Buildings

More information

Fire Risk Assessment. Guidance Notes. Location details. Risk Rating. Assessors. General notes

Fire Risk Assessment. Guidance Notes. Location details. Risk Rating. Assessors. General notes Fire Assessment Location details Company Name Site address Site contact name Phone Guidance Notes looking at the workplace to identify potential A hazard is something that has the potential to cause harm;

More information

University of London

University of London University of London Senate House and Stewart House Fire safety arrangements Contents 1. Introduction p.2 2. Fire Risk Assessment documentation p.2 3. Action to be taken by a person discovering a fire

More information

12/14/2013. Fire alarm and emergency power SPRINKLER HEAD

12/14/2013. Fire alarm and emergency power SPRINKLER HEAD Fire alarm and emergency power SPRINKLER HEAD 1 Alert signal Alarm signal Fire detector Heat detector Smoke detector Smoke alarm 1. Detector locations 1. Fire detector locations (3.2.4.11) 2. Smoke detector

More information

Regulatory Reform (Fire Safety) Order A short guide to making your premises safe from fire

Regulatory Reform (Fire Safety) Order A short guide to making your premises safe from fire Regulatory Reform (Fire Safety) Order 2005 making your premises safe from fire Introduction This booklet provides simple and practical advice to people responsible for fire safety in small and medium-sized

More information

This policy may also be used for routine work orders that are Life Safety in nature and cannot be completed within 45-days.

This policy may also be used for routine work orders that are Life Safety in nature and cannot be completed within 45-days. Policy: It is the policy of the St. Joseph Mercy Health System (SJMHS- Ann Arbor, Oakland, Livingston, Brighton, Chelsea and St. Mary Mercy Hospital- Livonia) and associated satellite facilities to assure

More information