1 HAZARDOUS AREA SOLUTIONS Lighting ATEX Zones 0,1, 2, 20, 21 and 22 v. 2.0/16
2 2 Delvalle, wide experience in manufacturing solutions for hazardous area WE PUT AT YOUR DISPOSAL We offer over 40 years providing solutions to demanding customers who require very specific characteristics and behaviour according to the sector and their needs. WHEREVER YOU GO We are committed to working closely with our customers, providing them with exceptional service and offering an advanced and extensive range of products with very competitive prices. CUSTOMIZE YOUR WIFI SYSTEM - WIRELESS HIGH STANDARD OF QUALITY AND SERVICES We only use materials provided by companies who offer the very highest quality, suitable and certified products. Our success is due to top quality assurance: ISO 9001, SGS, UL, TÜV, ISO and Ohsas ATEX, IECEx a nivel mundial. ALWAYS THINKING OUTSIDE THE BOX CONTACT US Confidentiality, reliability & quality atex@atexdelvalle.com ALSO ONLINE A team of professionals with high experience and ability to solve all your queries.
3 NOVA Explosion proof fluorescent luminaire Atex Zones 0, 1, 2, 20, 21 and 22 NOVA is a explosion proof fluorescent luminaire, with housing consisting of a polycarbonate tube with aluminium caps for led tubes. Great mechanical strength. Electronic control gear and lamp socket mounted on removable reflector for easier maintenance. There are 2 cable inputs (M25 thread) to offer the possibility of installation in continuous line. This explosion proof light fixture has been designed for hazardeous areas.
4 4 Explosion proof fluorescent luminaire Atex. NOVA SERIES Zones 0, 1, 2, 20, 21 and 22 Characteristics - Light fitting body: Polycarbonate tube of 3 mm thickness. - Reflector: Lacquered steel painted white. - End caps: Aluminum 2030 (polyester paint RAL 7047). - Equipment: Electronic or dimmable. - Working temperature: From -25 C to +55 C. - Wiring entry: M25 screw type (2 entries). - Accesories: 2 zinc covered clamps, with rubber protection and 2 eyebolt holders. - Glow wire test: 960 C. - Voltages and power 12v, 24v, 48v, 120v, 230v. Brida
5 5 Explosion proof fluorescent luminaire Atex. NOVA SERIES Zones 0, 1, 2, 20, 21 and 22 Technical specifications 1 Tube 2 Tubes PHOTOMETRY LIGHT FITTING REFLECTOR Polycarbonate tube of 4 mm. thickness Laquered steel painted white END CAPS Aluminium 2030 (polyester paint RAL 7047) POWER SOURCE V, 50-60Hz LAMP TYPE T8 IP PROTECTION IP 66 ELECTRICAL ISOLATION Class I WORK TEMPERATURE ACCESORIES INCLUDED CABLE ENTRY ATEX MARK -20ºC to +55ºC 2 steel zinc clamps with rubber protection and 2 eyebolts Holders. M25 thread (2 Entry).GLAND valid for NON ARMOURED CABLE 94/9/CE: II 2GD Ex d IIB + H2 T6 Gb Ex tb IIIC T85ºC Db
6 6 Explosion proof fluorescent luminaire Atex. NOVA SERIES Zones 0, 1, 2, 20, 21 and 22 Dimensions References References NOVA.F600.1A.E NOVA.F600.1A.R NOVA.F200.1A.E NOVA.F200.1A.R NOVA.F500.1A.E NOVA.F500.1A.R NOVA.F600.2A.E NOVA.F600.2A.R NOVA.F200.2A.E NOVA.F200.2A.R NOVA.F500.2A.E NOVA.F500.2A.R Description NOVA ATEX Light fitting 1 FLUO 18WE NOVA ATEX Light fitting 1 FLUO 18WR NOVA ATEX Light fitting 1 FLUO 36WE NOVA ATEX Light fitting 1 FLUO 36WE NOVA ATEX Light fitting 1 FLUO 58WE NOVA ATEX Light fitting 1 FLUO 58WE NOVA ATEX Light fitting 2 FLUO 18WE NOVA ATEX Light fitting 2 FLUO 18WR NOVA ATEX Light fitting 2 FLUO 36WE NOVA ATEX Light fitting 2 FLUO 36WE NOVA ATEX Light fitting 2 FLUO 58WE NOVA ATEX Light fitting 2 FLUO 58WE
7 7 Light fitting Atex LED. NOVA SERIES Zones 0, 1, 2, 20, 21 and 22 LED All the NOVA accesories can be use for the LED version (Cableglands, plug,...), except emergency kits. The photometry depends on the LED tube to be installed. References (LED version) All models are 230V References TUBE LED LENGHT (W) A B C WEIGHT (Kg) PACKAGING (uds) Description NOVA.600.1A ,7 1 NOVA Light fitting ATEX 1 LED NOVA A ,5 1 NOVA Light fitting ATEX 1 LED NOVA A ,3 1 NOVA Light fitting ATEX 1 LED NOVA.600.2A ,7 1 NOVA Light fitting ATEX 2 LED NOVA A ,5 1 NOVA Light fitting ATEX 2 LED NOVA A ,3 1 NOVA Light fitting ATEX 2 LED
8 POLAR Fluorescent Light fitting Atex Zones 0, 1, 2, 20, 21 and 22 The fitting of POLAR Delvalle has been developed from the fitting of Delvalle NOVA designed to operate in environments that can be formed or an explosive atmosphere being present according to the ATEX directive 94/9/ EC.. This light fixture is designed in order to obtain resistance against chemical products such as hydrocarbons or other chemical products that are agressive against polycarbonate. This is achieved by using a tempered borosilicate glass tube.
9 9 Fluorescent Light fitting Atex. POLAR SERIES Zones 0, 1, 2, 20, 21 and 22 Description The fitting of Delvalle POLAR has been developed from the fitting of Delvalle NOVA designed to operate in environments that can be formed or an explosive atmosphere being present according to the ATEX directive 94/9/EC.. This light fitting is designed in order to obtain resistance against chemical products such as hydrocarbons or other chemical products that are agressive against polycarbonate. This is achieved by using a tempered borosilicate glass tube Voltages and power 12v,24v, 48v, 120v, 230v. Applications Locations where volatile flammable liquid transfer from one container to another. Garages and car repair shops. It excludes garages of private use for parking of 5 vehicles or less. Interiors of paint booths where spray systems are used and their immediate environment when using solvents. Dries of material with inflammable solvents. Places of extraction of fats and oils that use inflammable solvents. Places with warehouses of inflammable opened liquids or that could be opened. Zones of laundries and dry cleaner s shops in which inflammable liquids are used. Rooms of fuels. Facilities where they take place, manipulate, store or consume inflammable gases. Pump rooms and / or compressor flammable liquids and gases. Interiors of refrigerators and freezers in which inflammable matters are stored in opened containers, easily perforables or with slightly consistent closings. Any other emplacement where there exists risk of explosion or of fire due to the presence of inflammable substances.
10 10 Fluorescent Light fitting Atex. POLAR SERIES Zones 0, 1, 2, 20, 21 and 22 Technical specifications 1 Tube 2 Tubes PHOTOMETRY LIGHT FITTING REFLECTOR Polycarbonate 7 mm thickness Laquered steel painted white END CAPS Aluminium 2030 (polyester paint RAL 7047) POWER SOURCE V, 50-60Hz LAMP TYPE T8 IP PROTECTION IP 66 ELECTRICAL ISOLATION Class I WORK TEMPERATURE ACCESORIES INCLUDED CABLE ENTRY From -25ºC to +55ºC 2 steel zinc clamps with rubber protection and 2 eyebolts Holders M25 thread (2 Entry) Voltage and power 12v, 24v, 48v, 120v, 230v. ATEX MARK II2GDExdIICT6 Gb Ex t IIC T85 Db
11 11 Fluorescent Light fitting Atex. POLAR SERIES Zones 0, 1, 2, 20, 21 and 22 Technical specifications References References POLAR.F600.1A.E POLAR.F600.1A.R POLAR.F1200.1A.E POLAR.F1200.1A.R POLAR.F600.2A.E POLAR.F600.2A.R POLAR.F1200.2A.E POLAR.F1200.2A.R Description POLAR ATEX Light fitting 1 FLUO 18WE POLAR ATEX Light fitting 1 FLUO 18WR POLAR ATEX Light fitting 1 FLUO 36WE POLAR ATEX Light fitting 1 FLUO 36WR POLAR ATEX Light fitting 2 FLUO 18WE POLAR ATEX Light fitting 2 FLUO 18WR POLAR ATEX Light fitting 2 FLUO 36WE POLAR ATEX Light fitting 2 FLUO 36WR
12 12 Light fitting Atex LED. POLAR SERIES Zones 0, 1, 2, 20, 21 and 22 LED All the POLAR accesories can be use for the LED version (cableglands, plug,...) except emergency kits. The photometry depends on the LED tube to be installed. References (LED version) All models are 230V References TUBE LED LENGHT (W) A B C WEIGHT (Kg) PACKAGING (uds) Description POLAR.600.1A POLAR Light fitting ATEX 1 LED POLAR A POLAR Light fitting ATEX 1 LED POLAR.600.2A POLAR Light fitting ATEX 2 LED POLAR A POLAR Light fitting ATEX 2 LED
13 VEGA Fluorescent Light fitting Atex Zones 2 and 22 This light fitting is IP68 protected. This allows a total protection against dust and water penetration during a long time. Impact protection is IK-10. SECURE is specifically designed for ATEC 2 and 22 zones, and is adequate for places where ocasionally may appear dust or atmosphere potencially explosive, but never as usual condition. 2 and 22 zones definition: Zone 2: Place where, during normal operation it isnêt probable explosive atmosphere formation, or in case that appears, it would be during a short period of time. Zone 22: The same as zone 2 but applied to flammable dust and air mix formation.
14 14 Fluorescent Light fitting Atex. VEGA SERIES Zones 2 and 22 Characteristics - LIGHT FITTING: Polycarbonate 3,5 mm thickness - Reflector: Glossy aluminium. - END CAPS: ABS NOVODUR ANTIESTATIC PLASTIC. - ATEX MARK: Zone 2: Ex II3GD Ex nr IIC T6 Gc. Zone 22: Ex t IIIC T85 ºC Dc. - WORK TEMPERATURE: From -15 C to +55 C. - ATEX cable glands included. - LOW WIRE TEST: 960 C. - Voltage and power 12v, 24v, 48v, 120v, 230v CLAMPS
15 15 Fluorescent Light fitting Atex. SERIE VEGA Zones 2 and 22 Technical specifications 1 Tube 2 Tubes PHOTOMETRY LIGHT FITTING REFLECTOR END CAPS Polycarbonate 3,5 mm thickness Glossy aluminium ABS NOVODUR ANTIESTATIC PLASTIC GLOW WIRE TEST 960ºC POWER SOURCE V, 50-60Hz (electronic) LAMP TYPE T8 IP PROTECTION IP-68 2m. ELECTRICAL ISOLATION Class I WORK TEMPERATURE From -15ºC to +55 C Voltage and power 12v, 24v, 48v, 120v, 230v. ACCESORIES INCLUDED ATEX MARK 2 galvanized steel clamps. Available antiestatic plastic clamp (black) ATEX cable glands. Zone 2: II 3GD Ex nr IIC T6 Gc. Zone 22: Ex t IIIC T85ºC Dc.
16 16 Fluorescent Light fitting Atex. VEGA SERIES Zones 2 and 22 Technical specifications References References VEGA.F600.1A.E VEGA.F1200.1A.R VEGA.F1500.1A.E VEGA.F600.2A.E VEGA.F1200.2A.E VEGA.F1500.2A.E Description VEGA ATEX Light fitting 1 FLUO 18WE VEGA ATEX Light fitting 1 FLUO 36WR VEGA ATEX Light fitting 1 FLUO 58WE VEGA ATEX Light fitting 2 FLUO 18WR VEGA ATEX Light fitting 2 FLUO 36WE VEGA ATEX Light fitting 2 FLUO 58WR
17 17 Light fitting Atex LED. VEGA SERIES Zones 2 and 22 LED All the VEGA accesories can be use for the LED version (Quick conection, suspensions...) except emergency kits. The photometry depends on the LED tube to be installed. Dimensions References (versión LED) All models are 230V References TUBE LED LENGHTD (W) L (mm) D (mm) PACKAGING (uds) Description VEGA.600.1A VEGA. Light fitting ATEX 1 LED VEGA A VEGA. Light fitting ATEX 1 LED VEGA A VEGA. Light fitting ATEX 1 LED VEGA.600.2A VEGA. Light fitting ATEX 2 LED VEGA A VEGA. Light fitting ATEX 2 LED VEGA A VEGA. Light fitting ATEX 2 LED
18 DENEB Fluorescent Light fitting Atex Zones 1 and 21 The DENEB luminaire of Delvalle has been designed to operate in environments in which an explosive atmosphere can be formed or can be present according to ATEX 94/9/CE directive, through the combination of Improved Security Protection e for gases and tb body protection for dust. Furthermore, the combination of M1 non flame propagator polycarbonate, as well as antistatic additives in the cap plastic makes it perfect for areas with explosion or fire risks.
19 19 Fluorescent Light fitting Atex. DENEB SERIES Zones 1 and 21 Applications Annexed areas to fuel loading and unloading, outdoors. Areas connected to flammable material valves and piping connections. Electric power plants. Paint and solvent warehouses. Waste treatment plants. Fertilizer treatment and deposits areas.
20 20 Fluorescent Light fitting Atex. DENEB SERIES Zones 1 and 21 Technical specifications References References DENEB.F600.1A.E DENEB.F1200.1A.R DENEB.F1500.1A.E DENEB.F600.2A.E DENEB.F1200.2A.E DENEB.F1500.2A.E Description DENEB ATEX Light fitting 1 FLUO 18WE DENEB ATEX Light fitting 1 FLUO 36WR DENEB ATEX Light fitting 1 FLUO 58WE DENEB ATEX Light fitting 2 FLUO 18WR DENEB ATEX Light fitting 2 FLUO 36WE DENEB ATEX Light fitting 2 FLUO 58WR
21 21 Fluorescent Light fitting Atex. DENEB SERIES Zones 1 and 21 Technical specifications 1 Tube 2 Tubes PHOTOMETRY LIGHT FITTING REFLECTOR END CAPS POWER SOURCE Flame Retardant Polycarbonate (M1) 2 mm anti UV Laquered steel painted white POLYCARBONATE M1 plus Viton O-RING JOINT A POWER SOURCE V, 50/60 Hz. ATEX certified ballast. LAMP TYPE T8 IP PROTECTION IP 66/68 2m. / IK 10 ELECTRICAL ISOLATION Class I WORK TEMPERATURE From 30 C to +50ºC ACCESORIES INCLUDED 2 stainless steel ceiling clamps. ATEX cable glands LOW WIRE TEST 960º C VOLTAGE AND POWER 12v, 24v, 48v, 120v, 230v. Zone 1 (Gas): II 2GD ATEX MARK Ex e mb IIC T4 Gb. Zone 21 (Powder): Ex tb IIIC T85ºC Db (T95ºC for 58W).
22 Oil refineries Chemical and petrochemical plants Oil and combustible liquid depots Offshore plants GEMMA Area projector LED Zones 2, 21 and 22 The enclosures of LED explosion-proof floodlight fittings are manufactured of die-cast aluminum alloy, with epoxy resin powder sprayed on the surfaces. Therefore, they have good anti-corrosion performance. The transparent shield is made by the toughened glass borosilicate, and the exposed fasteners are made of stainless steel. Explosion-proof light fitting s terminal box bottoom entry, is suitable for rubber-coated and the armored cable wiring. The internationally certified PHOENIX cage type terminals are selected as the internal terminals, which are convenient for wiring. Cree LEED pellet inside form light source modules through professional optics distribution. Heat disposal which is designed with thermology analysis and the heat-conducting structure os specially made aluminium base board ensure good operational heat release. It can satisfy the related requirements of illumination in petrochemical, chemical and marine industries. Esplosion-proof light fittings can be sorted as: floodlight type lamp and street type lamp. Onshore plants Fuel tanker Oil loading/unloading jetties LED high power and efficiency 100% Quality product
23 23 Area projector LED. GEMMA SERIE Zones 2, 21 and 22 Technical specifications References Characteristics References POWER Comparison metal halide Input frequency GEMMA120A 120W VAC 50/60 Hz GEMMA160A 160W VAC 50/60 Hz GEMMA200A 200W VAC 50/60 Hz It is energy-saving and environmental protection which the power consumption is only 19% of the same brightness of incandescent lamp. It is long life and maintenance-free which the service life is up to hours and the maintenance-free of long term. There is a feature of good electromagnetic compatibility and it does not cause interference to the system power grid. It is not influenced by the voltage fluctuations and can be operated in the wide voltage range of 200 ~240V AC. There is a good perfomance of vibration due to the LED is the solid-state light source. There is a wide range of ambient temperature, which can be operated in the ambient temperature range of -40ºC~+55ºC. The degree of protection is up to IP66. It is convenient to be mounted and maintained.
24 24 Area projector LED. GEMMA SERIE Zones 2, 21 and 22 Main technical data: Certification Ex mark Meet the standard IECEx Ex nr II C T* Gc Ex tb IIIC T* ºC Db (In certification) IEC60079 ATEX II 3 GD Ex nr IIC T* Ge Ex tb IIIC T* ºC (In certification) EN60079 Características eléctricas Intended use: Can be used in zone 2 Can be used in zone 21 and zone 22 Degree of protection: IP66 Rated voltage: 200V ~ 240V AC 50/60Hz Ambient temperature: -40ºC to + 40ºC /+55ºC Terminal: L1, N cage type terminal 2-2.5mm 2, PE terminal: 2 x 10mm 2 Cable entry: (Standard configuration) Moulded plastic 1 x M25 x 1.5, Outside diameter: 8-17mm Moulded plastic 1 x M25 x 1.5 stopping plug Light source code LED Lamp Power Temperature class* Ta < 40ºC Ta < 55ºC Weight 120W T6 T5 18Kg 160W T6 T5 18Kg 200W T6 T5 18Kg Luminous intensity distribution curve: Luminous intensity unit: cd C0/180 C90/270
25 25 Area projector LED. GEMMA SERIE Zones 2, 21 and 22 Gemma 120A 120W to 230W Explosion-proof floodlight IECEx certified Technical Data Ex mark: Ex nriict6/t5gc Ex tbiiic T6/T5C Db Intended use: zone 2, 21&22 Ambient temperature: -40 to 40/55 degrees Degree of protection: IP66 Rated voltage: VAC 50/60Hz Light source: LED120W Cable entry: 1xM25X1.5 plastic cable gland and 1xM25x1.5 plastic Stopping plugs Material of housing: die-casting aluminium-alloy Gemma 160A 160W to 230W Explosion-proof floodlight IECEx certified Technical Data Ex mark: Ex nriict6/t5gc Ex tbiiic T6/T5C Db Intended use: zone 2, 21&22 Ambient temperature: -40 to 40/55 degrees Degree of protection: IP66 Rated voltage: VAC 50/60Hz Light source: LED160W Cable entry: 1xM25X1.5 plastic cable gland and 1xM25x1.5 plastic Stopping plugs Material of housing: die-casting aluminium-alloy Gemma 200A 200W to 230W Explosion-proof floodlight IECEx certified Technical Data Ex mark: Ex nriict6/t5gc Ex tbiiic T6/T5C Db Intended use: zone 2, 21&22 Ambient temperature: -40 to 40/55 degrees Degree of protection: IP66 Rated voltage: VAC 50/60Hz Light source: LED200W Cable entry: 1xM25X1.5 plastic cable gland and 1xM25x1.5 plastic Stopping plugs Material of housing: die-casting aluminium-alloy
26 Oil refineries Chemical and petrochemical plants Oil and combustible liquid depots Offshore plants EMEREX LED lighting for safety warnings Zones 1, 2, 21 and 22 Emerex series Hazardous location emergency lights are designed to operate in hostile environments, atex, with battery include for hazardous areas that would damage ordinary signs and lights. Constructed from corrosion resistant materials, sealed ex d enclosures that can be used in outdoor environments or areas subject to water spray or moisture. The need for hazardous exit signs or emergency lights is not always just for the protection of the units themselves, but for that of those who might be in the vicinity. For example, Zones 1, 2, 21,22 fixtures are designed to function in areas where flammable gases or vapours and/or combustible dust exist. In these types of environments, an every-day fixture could accidentally ignite an explosive reaction. Specialized emergency lights and exit signs are designed specifically for their rated environments, and should always be installed in hazardous locations. Atex 94/9/EC Onshore plants Fuel tanker Oil loading/unloading jetties Ejemplo 100% Quality product
27 27 LED lighting Solutions. EMEREX SERIE Zones 1, 2, 21 and 22 Mechanical Features Body and lid: Low copper content aluminium alloy Internal frames: Stainless steel External adjustable brackets: Stainless steel Glass face: Shock and temperature resistant tempered glass Gaskets: Acid and hydrocarbon resistant silicone Bolts and screws: Stainless steel Assembly: See Dimensional drawing Emerex Entries: 2 x 1/2 NPT entries. Fixture kit with n.1 PLG1NB plug and n.2 FB1NBK cable gland Coating: Epoxy coating Ral 7035 (Light grey) Corrosion Resistance: The STANDARD of the aluminium alloy used has passed the tests required by standards EN (hot/humid cycles) and EN (salt mist tests) Detail of led Spotlights LED spotlights adjustable both horizontally and vertically to allow the directionality of light. Inside View Internal electrical part completely wired with silicone rubber cables with protective glass braid for high temperatures.
28 28 LED lighting Solutions. EMEREX SERIE Zones 1, 2, 21 and 22 Electrical features Power supply: Vac ±10% Rated frequency: Hz ±5% Power consumption: 20 W Connection: Direct connection to terminal board L, N, PE. Section 2,5 mm 2, suitable for loop-in/loop-out Power factor: >0,90 Rated current: 100 ma EMC (electromagnetic compatibility): EN 55015, EN , EN , EN THD (total harmonic distortion): <20% Vac Over-voltage protection: 2 kv Driver performances: Over-Voltage protection, Over-Current protection, Short-Circuit protection Dimmer: 7 Ah, 6 V. Discharge time 2 hours Photometric features LED Multichip: Cree CXA Viewing angle: 30 Colour temperature: 3500 K CRI: 80 Instant Restrike: YES Lumen: 595 lm (x2) Maximum light intensity: 1968 cd (x2) Overall efficiency: 59,5 lm/w Certification Data Photometric diagram Classification: Installation: Marking: Certification: Standards:: Class temperature: Ambient temperature:: Degree of protection: Group II Category 2GD zone 1 - zone 2 (Gas) zone 21 - zone 22 (Dust) CE 0722 Ex II 2GD Ex d IIC T6 Gb - Ex tb IIIC T85 C Db IP66 ATEX CML 15 ATEX 1007 IECEx CML CENELEC EN : 2012, EN : 2007, EN : 2014 and EUROPEAN DIRECTIVE 94/9/EC: 1994 IEC : 2011, IEC : , IEC : C (T6) Standard -20 C +55 C IP66
29 29 LED lighting Solutions. EMEREX SERIE Zones 1, 2, 21 and 22 Multichip LED formed by a matrix of LEDs connected together and covered with a layer of diffused phosphorus Modular system consisting of a internal reflector and a connector for COB Lid with glass face Lighting fixtures lid Cable glands for the connection of the electrical equipment to LEDs Supply unit body Terminals max. 2,5mm 2 Electronic inverter Terminals max. 2,5mm 2 7Ah 6V battery pack DESCRIPTION FEATURES Driver Vac Electronic inverter 90/264 V Battery pack 7 Ah 6V NiCd Lid with glass face Material: aluminium lid temperated glass Gasket between body and cover Material: NBR
30 30 Soluciones iluminación LED. SERIE EMEREX Zonas 1, 2, 21 y 22 Characteristics Técnicas References References LAMP TYPE Vatios Clase (Ta = +40 C) Temperatura máxima de superficie C (Ta = +40 C) WEIGHT Kg EMEREX20AB LED 20 W T
31 31 DELVALLE OFFERS OTHER SOLUTIONS ATEX Contact us at: We ll give a solution as Atex enclosure Luxorex Serie Increased safety enclosure Tribex Serie Atex terminal boxes Terbox Serie Control equipment Contrex Serie Plug and socket boxes Connex Serie Pressurized enclosure Ex p Peppex Serie
32 32 DELVALLE OFFERS OTHER SOLUTIONS ATEX Contact us at: We ll give a solution as Atex junction box Geoex Serie Flameproof enclosure Atex Ex d EJB Serie Workstations Pcex Serie Smartphones & Tablets Radios Atex Ex Walkies Talkies Ventilation and Air Conditioning
33 Flexible solutions Atex & IECEX HAZARDOUS AREA SOLUTIONS Paso del Prao, Oyón (Álava). Spain Telf atex@atexdelvalle.com Contact us, we will be available at any time.
CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights
CCA-03EX - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22 Directional LED spotlights Body and lid in coated aluminium LED for proper operation monitoring 127 ED.2018
More informationEVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation
EVL-B Shock-resistant tempered glass - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation costs - Suitable for GAS category IIC LED
More informationPYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white
. TECHNICAL DATA LIGHT FITTING REFLECTOR Polycarbonate tube of 4 mm. thickness Laquered steel painted white END CAPS Aluminium 2030 (polyester paint RAL 7047) POWER SOURCE LAMP TYPE 220-240V, 50/60Hz T8
More informationHigh bay LED lighting fixture
Supporting bracket EWL - Zone 1, 2, 21, 22 - Replacing traditional discharge lamps of up to 750W - Savings in energy, maintenance and installation costs - Instant, brilliant illumination - Suitable for
More informationXLFE-4/1. Borosilicate glass globe
XLFE-4/1 Borosilicate glass globe - Zone 1, 2, 21, 22 - Obstruction warnings - LOW INTENSITY LED technology - Lamp lifespan more than 10 years - Complies with ICAO, FAA Painted aluminium body Ex e terminal
More informationLuminex Series ATEX LED lighting
Hazardous Area Solutions Atex & IECEx Luminex Series ATEX LED lighting v. 1.2/15 Delvalle, wide experience in manufacturing solutions for hazardous areas In Delvalle we love challenges and in this moment
More informationINERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)
FLUORESCENT LIGHTING RMS-560.. Series - Fluorescent lighting fixtures TECHNICAL FEATURES RMS.. series lighting fixtures are ideally suited for ON and OFF-SHORE applications and all kinds of industries
More informationEWL. Supporting bracket
EWL Supporting bracket - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps of up to 750W - Saves in energy, maintenance and installation costs - Instant, bright illumination - Suitable for GAS category
More informationARRAN LED LED FLOODLIGHT. Standard Specification. Features
ARRAN LED LED FLOODLIGHT The Arran LED floodlight range is low energy with an instant on output and up to 130,000 maintenance free hours. Specifically designed for applications where moisture, dirt or
More informationEx LED light fittings
About us TEP Ex is a regional leader in manufacturing of explosion-protected electrical equipment. Through continuous development of new products and markets, modernization of technology and investment
More informationATM Lighting sp. z o.o
INSTALLATION AND MAINTENANCE MANUAL FOR EXPLOSIONPROOF LIGHT FITTING EXL390LED Carefully read the instructions before mounting the light fitting. ATM Lighting sp. z o.o., ul. Budowlanych 31, 80-298 Gdańsk,
More informationPRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres
PRODUCT OVERVIEW Light fittings, boxes & custom built control panels for explosive atmospheres LIGHT FITTINGS, BOXES & CUSTOM BUILT CONTROL PANELS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones
More informationATM Lighting sp. z o.o
INSTALLATION AND MAINTENANCE MANUAL FOR EXPLOSIONPROOF LIGHT FITTING EXL210LED Carefully read the instructions before mounting the light fitting. ATM Lighting sp. z o.o., ul. Budowlanych 31, 80-298 Gdańsk,
More informationUSER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218
CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.
More informationUSER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236
CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.
More information25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL
25W Hazardous Location Integrated LED Light Fixture - 3294 Lumens - Low Profile - ATEX IEC CSA UL Part #: HAL-19-25W-ITG-LED Page: 1 The Larson Electronics HAL-19-25W-ITG-LED 25 Watt Explosion Proof Low
More informationCCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.
Ex d CCAC - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66 Stainless steel bolts Polyester coating External earth screw Grub screws for opening lid External earth screw
More informationEJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67
Ex d EJBX AISI 316L stainless steel - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Quartz sand blasting Warning labels Mounting bracket Silicone gasket
More information60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx
60W Flameproof LED Emergency Linear Fixture - 100-250V AC - (2) 30W LED Lamps - ATEX/IECEx Part #: ATEX-HALP-EMG-48-2L-LED-2X30W-R1-220V Page: 1 The Larson Electronics ATEX-HALP-EMG-48-2L-LED-2X30W-R1-220V
More information208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC
208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC Part #: EPL-EMGX-LP-2X48-LED Page: 1 The Larson Electronics EPL-EMGX-LP-2X48-LED Low Profile Explosion Proof
More information26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE
26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE Part #: EPL-LP-12-LED Page: 1 The EPL-LP-12-LED from Larson Electronics is a Low Profile Explosion Proof
More informationTrusted worldwide since 1989 INTRINSICALLY SAFE RANGE
Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE Trusted worldwide We are now in our 28th year designing and manufacturing portable rechargeable lighting systems. Our main objective is to offer high
More informationATEX DELVALLE GENERAL CATALOGUE FLEXIBLE SOLUTIONS FOR HAZARDOUS AREAS UNDER ATEX & IECEX DIRECTIVES.
ATEX DELVALLE GENERAL CATALOGUE FLEXIBLE SOLUTIONS FOR HAZARDOUS AREAS UNDER ATEX & IECEX DIRECTIVES 3.18 With over 45 years of experience in design, manufacture and supply of electrical high quality Atex
More informationJAMIN 100. Compact impervious luminaire for ATEX zones. Zones 2, 21, 22
JAMIN 100 Compact impervious luminaire for ATEX zones Zones 2, 21, 22 JAMIN 100 ATEX LIGHTING THEY TRUST US: ACETEX CHIMIE, ADISSEO, ADNATCO (Abu Dhabi National Tanker Company), Airbus, BRITISH PETROLEUM,
More informationApplications. Standard Materials
Mercmaster III Low Profile Compact Fluorescent Luminaires Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors. Applications Enclosed and gasketed fixtures
More informationWHO WE ARE AND WHAT WE DO
WHO WE ARE AND WHAT WE DO TEPEx is the manufacturer of explosion protected electrical equipment. Our program includes Ex light fittings, Ex junction boxes, Ex terminal boxes and control units, Ex distribution
More information3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65
3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65 Product Technical Sheet 18, 36 and 58W single-lamp versions ST.0914.I Summary Application field 3 Structural characteristics 4 Electrical characteristics
More informationDTS Light fittings for explosive atmospheres
DTS Light fittings for explosive atmospheres For all zones and industrial applications LIGHT FITTINGS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones and industrial applications Tubular glass light
More informationSPARTAN SPX-HPBY LED Zone 1 Bay Light - IIB Applications
ZONE 1 ZONE 2 INDUSTRIAL SPARTAN SPX-HPBY LED Zone 1 Bay Light - IIB Applications ATEX and IEC Ex approved Zone 1 Zone 2 variant also available Ultra long life LED High lumen output LED Easy installation,
More informationINTRINSICALLY SAFE LIGHTING RANGE
Trusted worldwide since 1989 INTRINSICALLY SAFE LIGHTING RANGE SAFE PORTABLE RECHARGEABLE AC MAINS Trusted worldwide We are now in our 28th year designing and manufacturing portable rechargeable lighting
More informationEXPLOSIONPROOF LED LIGHT FITTINGS TO USE IN ZONES 1,21 & 2,22 KDB 15ATEX0049X NEW
EXPLOSIONPROOF LED LIGHT FITTINGS TO USE IN S 1,21 & 2,22 KDB 150049X NEW WORK WITH GDANSK / Poland ABOUT US ATM Lighting is a Polish manufacturer of technical light fittings for various industry sectors.
More informationLED NEW FB-SERIES LED NEW-SF FIXTURE LED NEW-SD FLOODLIGHT LED NEW-SD STREET. LED Explosion-proof Platform Light. LED Tri-proof Light
LED NEW FB-SERIES LED NEW-SF FIXTURE LED Explosion-proof Platform Light LED Tri-proof Light LED Explosion-proof Highbay Light LED NEW-CF FIXTURE LED Highbay Light LED Explosion-proof Light LED Explosion-proof
More informationLED Protected Catalogue
LED Protected Catalogue Q3-18 Contents 06 Welcome 09 Vapour Proofs 12 Hazardous Zone 1 18 Hazardous Zone 2 21 Prison Luminaires 04 Province Lighting Contents LED Protected Catalogue LED Protected Catalogue
More informationSafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas. Patent Pending
SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas About Dialight Dialight (LSE: DIA.L) is leading the energy efficient LED lighting revolution around the world for industrial
More informationDräger Polytron 5700 IR Detection of flammable gases and vapours
Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive
More informationCoreLine Waterproof the clear choice for LED
Lighting CoreLine Waterproof the clear choice for LED CoreLine Waterproof Whether for a new building or renovation of an existing space, customers want lighting solutions that provide quality of light
More informationInspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN
Inspection Light LED Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3 1.3 Conformity
More information100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof
100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof Part #: EPLX-HB-100W-RD2-LED-TRC Page: 1 The EPLX-HB-100W-RD2-LED-TRC Explosion Proof Low Bay AC LED light
More informationHDL106 LED LUMINAIRES. For Harsh & Hazardous Environments.
HDL106 LED LUMINAIRES For Harsh & Hazardous Environments www.chalmit.com Quality, Reliability and Low Maintenance Our LED Product Range Chalmit has over a century s worth of experience in providing cutting
More informationHazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED
Hazardous Area LED Lighting Hazard Gard LED Luminaires Hazard Gard EVLL LED Hazard Gard EVLL LED Safe. Reliable. Efficient. Featuring the industry's broadest range of LED luminaires for harsh and hazardous
More information150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam
150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam Part #: EPLC2-HB-155W-LED-PND Page: 1 The Larson Electronics EPLC2-HB-155W-LED-PND Explosion Proof High Bay light
More informationSylproof Superia LED G2
Range Features 665mm, 1265mm, 1565mm single and twin weatherproof LED luminaires Impresive performance, up to 7,837lm (luminaire lument output on 80W twin / double version) High efficiency, will help you
More informationSafeSite LED Area Light - ATEX / IECEx. for Indoor and Outdoor Industrial Applications
SafeSite LED Area Light - ATEX / IECEx for Indoor and Outdoor Industrial Applications On when it matters most. Products and solutions that protect your business 2 Features & Benefits 5 year warranty L70
More informationC1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount
C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount Part #: EPL-LED-50W-RT-JB2 Page: 1 The Larson Electronics EPL-LED-50W-RT-JB2 Explosion Proof High Bay light
More informationBC9700 series High Power LED Explosion Proof Light
BC9700 series High Power LED Explosion Proof Light Characteristics IECEx ATEX LM79 LM8 IP 66 Ta 0/55 Ta -0 Application Zone,zone ;zone,zone Suitable for Low installation height in Moist corrosive environment,such
More informationSOLUZIONI PER ATMOSFERA ESPLOSIVA
catalogo ATEX 2015 SOLUZIONI PER ATMOSFERA ESPLOSIVA ATEX catalogue book 2016 SOLUTIONS FOR EXPLOSIVE ATMOSPHERES Since 1904 In 1904 PALAZZOLI began its activity in Brescia when electrical energy was first
More informationelevated ambient capability. in installations where moisture, dirt, dust, vibration, corrosion and rough usage are problems.
V Series H.I.D s VG, VN, VZ Series Wet Locations Marine Locations NEMA 3,3R,4,4X,7 < VG > < VN > < VZ > Type of Explosion-proof Fixture Wattage Class I Division 2 Group A,B,C,D Class II Division 1,2 Group
More informationGRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S
www.stahl.de > Corrosion resistant omnidirectional high output sounder > Integrated Ex d enclosure > Extreme temperature range > 3 stage alarm with independant tone selection for V DC systems > IP66 IP67
More informationPhoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.
Phoenix Explosion-proof Pan & Tilt heads and Camera Housings for potentially exposed environments Answers for infrastructure. Video monitoring under extreme conditions Security Products from Siemens is
More informationExplosion Proof UV/Visible Light Fluorescent Fixture - Paint Spray Booth, Rigs - Two Circuit Lamps
Explosion Proof UV/Visible Light Fluorescent Fixture - Paint Spray Booth, Rigs - Two Circuit Lamps Part #: EPL-48-2L-T8-VISUVA Page: 1 The Larson Electronics EPL-48-2L-T8-VISUVA Explosion Proof UV/Visible
More informationLow Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E
Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer - 140 - C1D1 - C2D2 - ISO 14644/FS-209E Part #: HALD-24-1X150LED-V2-140DB Page: 1 Made in the USA The HALD-24-1X150LED-V2-140DB from Larson Electronics
More informationFlow LED robust and streamlined
Lighting Flow LED robust and streamlined Flow LED Specially designed for slow-traffic underpass lighting, Flow LED combines elegance and style with high-performance LED lighting. Equipped with the newest
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExBG15E and BExBG10E Flameproof / Increased Safety Xenon Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG15E and BExBG10E beacons are flameproof
More informationREGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC
EUROPEAN ATEX DIRECTIVE > European Directive 2014/34/EU ATEX Directive 2014/34/EU is a "new approach" directive that applies to protective systems against explosions as well as all equipment used in or
More informationC2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens
C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens Part #: EPLC2-HB-50LED-RT Page: 1 The Larson Electronics EPLC2-HB-50LED-RT Explosion Proof High Bay light
More informationExplosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips
Explosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips Part #: HAL-EMG-48-2L-LED-D-V2 Page: 1 Made in the USA The Larson Electronics HAL-EMG-48-2L-LED-D-V2 Hazardous
More informationCoreLine Wall-mounted the clear choice for LED
Lighting CoreLine Wall-mounted the clear choice for LED CoreLine Wall-mounted Whether for a new building or renovation of an existing space, customers want solutions that provide quality of light and substantial
More informationExplosion Proof LED Light - Equivalent to Watt HID C1D2, UL Listed
Explosion Proof LED Light - Equivalent to 150-175 Watt HID C1D2, UL Listed Part #: EPLC2-LED-175W Page: 1 Made in the USA The Larson Electronics explosion proof LED is designed for use in hazardous work
More informationATEX - ATmosphere EXplosive
ATEX - ATmosphere EXplosive 153 DIRECTIVE 94/9/CE (ATEX= ATMOSPHERE EXPLOSIVE) OF THE EUROPEAN PARLIAMENT AND COUNCIL (MARCH 23, 1994): IMPACT ON LIGHTING FIXTURES APPLICATIONS Polycarbonate and steel
More informationSECTION INTERIOR LIGHTING
SECTION 26 51 00 INTERIOR LIGHTING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationOfficine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0
Officine Meccaniche M.A.M. Apparecchiature Antideflagranti DOCUMENT IS-EJB-A-14 rev. 0 Instructions Flameproof enclosures EJB../W series for command, control, signaling and/or automation Emission date:
More informationXEON. High impact resistant body and PC cover. Double layer coating. through wiring. Build-in microwave sensor.
XEON is a rectangular shape wall or ceiling fixture. This luminaire family has a robust aluminium construction housing with a high impact resistant polycarbonate diffuser. It is to be operated with LED
More information120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable
120W Hazardous Location LED Fixture - 12-24V DC - Modbus TCP/IP - Network Controlled - Dimmable Part #: HAL-ANC-60-120W-ITG-LED-DIMM-1224 Page: 1 The Larson Electronics HAL-ANC-60-120W-ITG-LED-DIMM-1224
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT
More informationOperating Instructions
Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect
More informationNexLED. Ex e LED BULKHEAD. Features. Standard Specification. International Approvals. NexLED with Exit Sign kit
NexLED Ex e LED BULKHEAD 62 NexLED with Exit Sign kit The NexLED bulkhead utilises the latest LED technology to provide instant illumination. The NexLED requires no re-lamping making it virtually maintenance
More informationAdditional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.
Additional Operating Instructions SITRANS F Vortex flowmeters Ex-d Edition 09/208 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4
More informationD O M E S T I C LED. Lighting C O M M E R C I A L
D O M E S T I C LED C O M M E R C I A L Vela Advance IP65 Dimmable LED 9W Fire Rated, Low Profile Downlights Fixed, tilt & a n t i - g l a re options Option The VELA Advance Range offers a High Quality
More information40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated
40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated Part #: HALD-24-1X40CPR-LED-V2 Page: 1 The Larson Electronics HALD-24-1X40CPR-LED-V2 Explosion Proof LED Fixture provides
More information50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved
50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved Part #: EPLC2-TRN-50LED-RT Page: 1 The Larson Electronics EPLC2-TRN-50LED-RT Explosion Proof compact
More informationEX-SIGNAL- AND ESCAPE SIGN LUMINAIRS
1 EX-SIGNAL- AND ESCAPE SIGN LUMINAIRS 2 Co op er Cr ou se -H inds 20 08 - al l ri gh ts re se rv ed 3 4 5 6 7 8 EMERGENCY LIGHTING CENTRAL OR DECENTRAL 3.21 EX-ESCAPE SIGN LUMINAIRES EXIT EX-ESCAPE SIGN
More information300W EXP LED Light - 35,000 Lm - 3' Cart Mount - Quick Change Mount - C1D1-100' 16/3 SOOW- EXP Plug
300W EXP LED Light - 35,000 Lm - 3' Cart Mount - Quick Change Mount - C1D1-100' 16/3 SOOW- EXP Plug Part #: EPL-QC-16C-3FT-2X150LED-RT-100-EPP Page: 1 The EPL-QC-16C-3FT-2X150LED-RT-100-EPP Portable Explosion
More informationATEX. Wolf Safety Lamp Company. The widest range of portable ATEX lighting approved for use in explosive atmospheres
Includes NEW ATEX Fluorescent Leadlamp Range Wolf Safety Lamp Company The widest range of portable ATEX lighting approved for use in explosive atmospheres Wolf Safety have Ex lighting products for all
More informationATEX catalogue book SOLUTIONS FOR EXPLOSIVE ATMOSPHERES
ATEX catalogue book 20172018 SOLUTIONS FOR EXPLOSIVE ATMOSPHERES Since 1904 In 1904 PALAZZOLI began its activity in Brescia when electrical energy was first used in the industry. The Company is specialized
More informationExplosion-proof Immersion Heater Type D-8660
Explosion-proof Immersion Heater Type D-8660 Sinus Jevi has developed explosionproof Ex de heating equipment, for hazardous area. The flame-proof (d) enclosures have been designed for non save areas to
More informationOPTIBAR DP 7060 Supplementary Instructions
OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,
More informationHazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs
Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs Part #: HALP-ANC-48-2L-LED-D-V2 Page: 1 Made in the USA The Larson Electronics HALP-ANC-48-2L-LED-D-V2
More informationmanual addendum DELPHI Ex
manual addendum DELPHI Ex II 2G Ex eb IIC T4 Gb II 2D Ex tb IIIC T135 C IP65 Db Tamb=-20 +40 C Reference list: Norm (last issue) Title Dir. 2014/34/UE EN 60079-31 EN60079-0 EN60079-7 Equipment and Protective
More informationEVLED201 36W Led Luminaire. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 14.85
80 South Street 7596-726, TX Nacogdoches Phone: 96-569-791 Fax: 96-560-685 EVLED201 6W Led Luminaire Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Long Description
More informationDräger Polytron 5200 CAT Detection of flammable gases and vapours
Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion
More information150W Explosion Proof LED Flood Light - Surface Mount Lumens - C1D V AC
150W Explosion Proof LED Flood Light - Surface Mount - 17500 Lumens - C1D1-120-277V AC Part #: EPL-LED-150W-RT Page: 1 The EPL-LED-150W-RT from Larson Electronics is an Explosion Proof High Bay LED Light
More informationEx Mark:Ex d eb ⅡB T6 Gb
Swordfish Series ED Explosion proof Floodlight Ex Mark:Ex d eb ⅡB T6 Gb Ex tb ⅢC T80 Db KHJ-ED Explosion Proof ighting 1 INTRODUCTION Features and benefits 1.Energy saving. Reduce the number of luminaires
More informationFlow LED robust and streamlined
Lighting Flow LED robust and streamlined Flow LED Specially designed for slow-traffic underpass lighting, Flow LED combines elegance and style with high-performance LED lighting. Equipped with the newest
More information48W Fluorescent T8 Light w/ Emergency Backup Dimmable Ballast - (2) 2 Foot T8 Lamps - C1D2
48W Fluorescent T8 Light w/ Emergency Backup Dimmable Ballast - (2) 2 Foot T8 Lamps - C1D2 Part #: HAL-EMG-24-2L-T8-D Page: 1 Made in the USA The Larson Electronics HAL-EMG-24-2L-T8-D Hazardous Area Fluorescent
More information25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC
25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame - 120-277V AC Part #: EXHL-TRN-LE1-1227 Page: 1 Made in Texas The EXHL-TRN-LE1-1227 from Larson Electronics is an Explosion
More informationRating. Class I Div II
TYPE: LED HAZGLOBE : HZ2 LARGE - 26 WATT SPECIFICATIONS. Housing and Lens Frame: Die cast aluminum for thermal management Lens: Tempered Glass Cage: 0.25 dia Wire; 304 stainless steel Finish: TGIC thermoplastic
More informationDräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors
Dräger Polytron 5700 Fixed Gas Detector Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Including e-box for increased safety wiring The Dräger
More informationCoreLine Batten the clear choice for LED
Lighting CoreLine Batten the clear choice for LED CoreLine Batten Whether for a new building or renovation of an existing space, customers want lighting solutions that provide quality of light and substantial
More informationExplosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1
Explosion Proof Light - 400 Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1 Part #: EPL-HB-400W-MH Made in the USA The EPL-HB-400W-MH metal halide, hazardous area light fixture from Larson Electronics
More informationTECHNICAL SHEET. Road and residential lighting luminaire MATRIX-S-01 60LED. About the product MATRIX-S LED
No. 528/ 07.01.2015, Edition No. 10, 1/5 Road and residential lighting luminaire MATRIX-S-01 60LED MATRIX-S-01 60 LED About the product MATRIX range of luminaries represents the solution for the challenges
More informationEVLPF Series Compact Fluorescent
EVLPF Series Low Profile Hazard Gard Luminaires Cl. I, Div. 1, Groups B (GB Suffix), C, D Cl. I, Zone 1, Groups IIB + H2 (GB Suffix), IIB, IIA Cl. II, Div. 1, Groups E, F, G Class III, Simultaneous Presence
More informationINSTRUCTION & SERVICE MANUAL
INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following
More informationMASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL
SECTION 265100 - INTERIOR LIGHTING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Interior lighting fixtures, lamps, and ballasts. 2. Emergency lighting units. 3. Exit signs. 4.
More informationSpecification Sheet. Certificates. Features. Application. Anti-Explosive Lamp
Anti-Explosive Lamp Specification Sheet Product Introduction ALT's anti-explosive lamp can be safely used in hazardous locations such as power plants, oil and natural gas drilling stations and refineries,
More informationLUXCOMFO TM LED Flood Light Datasheet
Datasheet LUXCOMFO TM LED Flood Light is a very cost-effective LED flood light series. The IP65 outdoor rated flood lights are designed to replace traditional halogen lamps with excellent energy and cost
More informationOLUX LED Flood Light OSRAM. Datasheet APPLICATIONS.
OLUX LED Flood Light Datasheet OLUX LED FLOOD is a cost-effective, durable and environmentally-preferable LED flood light series. The IP66 outdoor rated OLUX LED FLOOD S, M and L are designed to replace
More informationGUB. Ex d. Screw-on lid. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 8 sizes - IP66. Polyester coating. Cast mounting feet
Ex d GUB Screw-on lid - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 8 sizes - IP66 Polyester coating Cast mounting feet GUB-05 with lever on lid External earth screw in body Safety
More informationWeighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE
Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE PUE HX5.EX explosion-proof hazardous area indicator ATEX APPROVAL PUE HX5.EX is a cutting-edge weighing indicator, designed to
More informationDräger Polytron 5100 EC Detection of toxic gases and vapors
Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen. It uses a high performance
More informationLMV Series W Low Profile - Medium Base
L LMV Series 50-150W Low Profile - Medium Base Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II, Groups E, F, G;