2015 New GFCI Requirements

Size: px
Start display at page:

Download "2015 New GFCI Requirements"

Transcription

1 2015 New GFCI Requirements Why are GFCI receptacles changing in 2015? The Underwriters Laboratory Standard (UL 943) for GFCI will require manufacturers to include a new function for all ground fault receptacles being built after June 29, What is the new functionality requirement? Each GFR must automatically monitor the GFCI circuit/functionality periodically every (3) hours or less. It must also automatically test within (5) seconds of power to the device. What if the GFR can no longer provide GFCI protection? The unit should trip and deny power. Two conditions may follow at this point: (1) Unit is no longer able to reset & denies power (or) (2) Unit can reset & is subject to the next auto-monitoring test cycle within (5) seconds of power to the device All GFR s must provide an audible or visual indication in the event it does not go into power denial.

2 2015 New GFCI Requirements Standard 943: June 29, 2015 Changes Automatically monitor GFCI circuit/functionality periodically Automatically test within (5) seconds of power to line & load terminals Periodically means every (3) hours or less If the unit can no longer provide GFCI protection, it must comply with the following Deny Power (trip with the inability to reset) Trip with the ability to reset, subject to the next auto-monitoring test cycle Visual and/or audible indication as permitted by UL 943 (6.30.8)* Visual and/or audible indication* GFCI must visually or audibly indicate that it does not go to power denial* * Note: The audible/visual indicator allowance only applies to unique catastrophic events. An example is when a branch circuit is damaged from a short circuit or other extreme condition. Often in this type of event, all devices in the circuit, along with electronics, incur significant damage. If power is still available to that circuit, the unit must indicate it has lost it s ability to provide protection (LED or alarm).

3 What Is Changing For The Customer External Change minimal No change in wiring or method of installation No change in user interface, same physical size Added power indicator (solid green when powered up) Added trip indicator (solid red when tripped) Today GF20GYLA New self test GFRST20GY Internal Change major New microcontroller/programmed for auto monitor Major component additions to printed circuit board for filtering, diagnostics and monitoring Single printed circuit board changed to a double sided PCB Added power LED board Added electronics for trip indicator (solid red when tripped) 100% new tooling across all lines for internal design changes

4 All Current GFR Version To Be Replaced By Self Test Non TRWR TRWR HG Non TRWR HG TRWR Blank Face All existing product lines will be transitioned to the new self test power denial design Timing: June 2015 New Versions for 2015 Include: Isolated Ground* Combination Switch/GFR Lighted* Weather Resistant Only* Alarm* Tamper Resistant Only* Made In USA (Specials)* * Available in Hospital Grade & Non HG Alarm

5 2015 New Functionality Auto Monitor/Power Denial Hubbell GFR will monitor its ability to provide ground fault protection every 60 seconds All monitored failures will result in power denial except for an open solenoid condition For an open solenoid condition, LED will flash red Alarm version will also provide audible alert New Versions for 2015 Isolated Ground* Combination Switch/GFR Lighted* Weather Resistant Only* Alarm* * Available in Standard and Hospital Grade Tamper Resistant Only* Alarm

6 Q & A New Self Test GFCI Receptacle (GFR) Q: Can I still use current generation ground fault receptacles after June 29, 2015? A: Absolutely, the current Bryant GFR can no longer be produced after June 29 th. However, these devices produced prior to this date can be sold by manufacturers & distributors until their inventories are depleted. There is no time limitation on purchase or use of the current product. Q: When will the new self test GFR s be available for sale? A: Stock for the core product lines including tamper resistant will be on the shelves at the end of June. The balance of our new products and configurations will in stock Q3, Q: What indicators does the standard Hubbell GFR provide? A: Power indicators include solid green for power, solid red for trip condition and flashing red for end of life condition. Q: How does the alarm version function? A: The alarm GFR includes all LED indicators that are in the standard product. In addition, an audible alarm will sound when either the unit trips and/or is in end of life. A silencing feature is provided on the face of the device to turn off when needed. Q: Are there any new versions of self test GFR included in this launch? A: Yes, there are several new product families being introduced. These include Isolated Ground, Alarm, Nightlight and Combination Switch/GFR TR GFCI. In addition per VOC, a tamper resistant only and weather resistant only construction will be offered. The combination of TRWR will also be available.

AUTOGUARD Hubbell Self Test Ground Fault Circuit Interrupters. More innovation. More protection. More safety.

AUTOGUARD Hubbell Self Test Ground Fault Circuit Interrupters. More innovation. More protection. More safety. AUTOGUARD Hubbell Self Test Ground Fault Circuit Interrupters. More innovation. More protection. More safety. The GFCI that Tests Itself! You may forget, but Hubbell AutoGuard GFCI won't. Nothing delivers

More information

CIRCUITPRO Self Test Ground Fault Receptacles

CIRCUITPRO Self Test Ground Fault Receptacles IRUITPRO Self Test Technology 1st introduced by ryant over 10 years ago! self test monitoring now required in 2015 UL 943 GFI Safety Tamper- Resistant Hospital Grade ombo Switch/GFI udible ryant Self Test

More information

FAULT CODES. Included in this section are instructions to Reset the two Hot Tank Overload Devices (High Safety Limit).

FAULT CODES. Included in this section are instructions to Reset the two Hot Tank Overload Devices (High Safety Limit). FAULT CODES Fault Code Index 1. Blue Chilling LED Flashing Cold Sensor Fault 2. Red Heating LED Flashing Hot Sensor Fault 3. Green LED Flashing Filter Service Alert 4. All but Power Button LEDs Flashing

More information

MORE PROTECTION. MORE FUNCTIONALITY. IN MORE ENVIRONMENTS.

MORE PROTECTION. MORE FUNCTIONALITY. IN MORE ENVIRONMENTS. PASS & SEYMOUR SELF-TEST GFCI RECEPTACLES REINVENTING SAFETY ALL AROUND MORE PROTECTION. MORE FUNCTIONALITY. IN MORE ENVIRONMENTS. 2 SAFETY IS OUR CODE When we invented the first GFCI receptacle, our goal

More information

To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator.

To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator. Section 5 Operation To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator. Figure 5-1 Built-in Touchpad (Seven-Segment Display) Figure 5-2 Model 5230 Remote

More information

CHAPTER 20 SERVICE EQUIPMENT

CHAPTER 20 SERVICE EQUIPMENT SERVICE EQUIPMENT CHAPTER 20 SERVICE EQUIPMENT Service equipment includes service cabinets and the equipment and materials necessary for installation. 20.1 Signal Service Cabinet For MnDOT traffic control

More information

SECTION ISOLATED POWER SYSTEMS

SECTION ISOLATED POWER SYSTEMS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 20 11 ISOLATED POWER SYSTEMS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also, delete any other item or paragraph not applicable to

More information

AF/GF dual-purpose receptacles

AF/GF dual-purpose receptacles Eaton Wiring Devices OBC AF/GF dual-purpose receptacles AF/GF dual-purpose receptacles Arc fault and ground fault protection in one device In Stock July 2016! Eaton Wiring Devices OBC AF/GF dual-purpose

More information

Introducing a revolutionary new line of 15 and 20 amp devices engineered for fast and easy installation

Introducing a revolutionary new line of 15 and 20 amp devices engineered for fast and easy installation Sold by: http://www.twacomm.com Toll Free: (877) 389-0000 Commercial / Industrial Introducing a revolutionary new line of 15 and 20 amp devices engineered for fast and easy installation Introduction lev-lok

More information

CAUTION READ CAREFULLY

CAUTION READ CAREFULLY Docking Drawer Install Manual for Style/Mighty Drawer 0230-00002. r5 10/21/2015 Applicable Models: 0290-00011, 0290-00011W, 0290-00013, 0290-00013W CAUTION READ CAREFULLY Failure to follow these instructions

More information

Gas Safety Products. Installation, operating and maintenance. Merlin 1000S+i Gas & Electric Utility Controller. Rev: 03 Date:

Gas Safety Products. Installation, operating and maintenance. Merlin 1000S+i Gas & Electric Utility Controller. Rev: 03 Date: Gas Safety Products Merlin 1000S+i Gas & Electric Utility Controller Installation, operating and maintenance Rev: 03 Date: 14-08-18 1 Table of contents 1 General information... 3 2 Installation... 3 2.1

More information

SECTION (16140) - WIRING DEVICES

SECTION (16140) - WIRING DEVICES SECTION 26 27 26 (16140) - WIRING DEVICES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Receptacles, Connectors, Switches, and Finish Plates. B. Related Sections: 1. Section 00 31 13.43 (00370) -

More information

Across-the-Line SERIES MP300 Combined Manual and Automatic

Across-the-Line SERIES MP300 Combined Manual and Automatic Across-the-Line SERIES MP300 Combined Manual and Automatic Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for Centrifugal Fire Pumps

More information

Variable Frequency Drive SERIES MP800 VFD

Variable Frequency Drive SERIES MP800 VFD Metron Fire Pump Controls and Accessories Variable Frequency Drive SERIES MP800 VFD Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for

More information

ENGINE GENERATORS AND ACCESSORIES

ENGINE GENERATORS AND ACCESSORIES ENGINE GENERATORS AND ACCESSORIES GENERAL INFORMATION 1.1 This section applies to engine generators and accessories. DESIGN REQUIREMENTS 2.1 The Engineer of Record will consult with the University s Engineering

More information

Soft Start Series MP700 Solid State, Reduced Voltage

Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s

More information

SECTION NURSE CALL SYSTEM

SECTION NURSE CALL SYSTEM NURSE CALL SMARTCARE NURSE CALL SOLUTION Architectural Specifications Part 1 General SECTION 275223 - NURSE CALL SYSTEM 1.0 Summary 1.1 This section includes nurse call system and requirements for system

More information

Gas Safety Products. Installation, operating and maintenance 11/18/2015. Merlin 1000S+ Gas Utility & Electrical Isolation Controller

Gas Safety Products. Installation, operating and maintenance 11/18/2015. Merlin 1000S+ Gas Utility & Electrical Isolation Controller Gas Safety Products Installation, operating and maintenance 11/18/2015 American Gas Safety LLC 1 Table of contents 1 General information... 3 2 Installation... 3 2.1 Panel Mounting.... 3 2.2 Power Supply....

More information

Remote Alarm Panels Features

Remote Alarm Panels Features Features 1-1 DFDAP-M / FDAP-M Remote Product Description Eaton s Remote s are designed to provide audible and visual alarms for Electric and Diesel Fire Pump Controllers. These remote panels are located

More information

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12 PAGE 1 OF 12 TABLE OF CONTENTS PAGE 1. SAFETY PRECAUTIONS 1.1. Electrical shock 3 2. APPLICATION 3 3. INSTALLATION 3.1. Mount indoor alarm display 3.2. Mount the outdoor junction box 3.3. Install interconnecting

More information

Model 5100A, 5200A, and 5100ALBV Owner s Manual

Model 5100A, 5200A, and 5100ALBV Owner s Manual AGF Manufacturing Inc. Model 5100A, 5200A, and 5100ALBV Owner s Manual INST-COLLECTanDRAIN_V001.9 Model 5100ALBV Model 5100A Model 5200A Model 5100A, 5200A and 5100ALBV Owner s Manual COLLECTa ndrain Anti-Trip

More information

Gas interlock system S & 100 CS

Gas interlock system S & 100 CS Gas interlock system - 100 S & 100 CS Features: Available as a stand-alone panel or supplied complete with air pressure switches (100 S) or integral current sensors (100 CS) Comprehensive fan, fire & emergency

More information

Arrow Hart hospital grade self-test GFCI receptacles

Arrow Hart hospital grade self-test GFCI receptacles Description 2-pole, 3-wire grounding 15A, 125V/AC; 20A, 125V/AC NEMA 5-15, 5-20 Design features Performs periodic self-tests to ensure integrity of GFCI protection. Meets and exceeds 10 ka short circuit

More information

GFCI Products Buying Guide

GFCI Products Buying Guide GFCI Products Buying Guide A Ground Fault Circuit Interrupter (GFCI) is an important safety device to have in a home to help protect people from electrical shocks due to hazardous ground faults. Ground

More information

ELECTRICAL DH VERSUS DR SERIES OPTIONS LISTED IN THE ONLINE AND PRINT CATALOG FOR ENVIRONMENT ONE DH071/DR071 STATIONS. WHICH DO YOU SELECT?

ELECTRICAL DH VERSUS DR SERIES OPTIONS LISTED IN THE ONLINE AND PRINT CATALOG FOR ENVIRONMENT ONE DH071/DR071 STATIONS. WHICH DO YOU SELECT? ELECTRICAL DH VERSUS DR SERIES OPTIONS LISTED IN THE ONLINE AND PRINT CATALOG FOR ENVIRONMENT ONE DH071/DR071 STATIONS. WHICH DO YOU SELECT? The DH071 is the hardwired or wired model where a cable connects

More information

The most complete line of proven safety solutions.

The most complete line of proven safety solutions. P&S Tamper-Resistant Receptacles The most complete line of proven safety solutions. Meets National Electrical Code Requirements designed to be better. P&S Tamper-Resistant Receptacles the full line to

More information

GPPS-evo V3.3. Installation Instructions

GPPS-evo V3.3. Installation Instructions GPPS-evo V3.3 Installation Instructions The GPPS-evo is a gas pressure proving system with optional CO2 detection. The system will perform a down stream integrity check ensuring gas tightness before use,

More information

OPERATING GUIDE FOR YOUR RP1054D KEYPAD

OPERATING GUIDE FOR YOUR RP1054D KEYPAD OPERATING GUIDE FOR YOUR RP1054D KEYPAD Napco 1992 DESIGN PATS. PENDING Technical Manuals Online! - http://www.tech-man.com CONGRATULATIONS!...on your purchase of a NAPCO Magnum Alert security system.

More information

SECTION K. Table of Contents. Wiring Device-Kellems. Heavy Duty Commercial GFCIs. Extra Heavy Duty Industrial GFCIs

SECTION K. Table of Contents.   Wiring Device-Kellems. Heavy Duty Commercial GFCIs. Extra Heavy Duty Industrial GFCIs SECTION K Table of Contents Extra Heavy Duty Industrial GFCIs Heavy Duty Commercial GFCIs Portable GFCI Products Product Page Hubbell Self Test GFCI Patented Technology K-2 Extra Heavy Duty Industrial

More information

Afci TR Duplex 20A 125V La. Features amperage rating 20. Dimensions and Weight Width 3.3. Long Description

Afci TR Duplex 20A 125V La. Features amperage rating 20. Dimensions and Weight Width 3.3. Long Description 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 TRAFCI20LA Afci TR Duplex 20A 125V La Eaton Wiring Devices Catalog Number Manufacturer Weight per unit Product Category

More information

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1. Data Sheet Ref: 90501085 WD-CS Water leak detection cable Technical Overview The WD-CS range of cable sensors are typically used to detect water leaks usually under floors, and are used in conjunction

More information

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL. Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL www.aquaticsentry.com TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 3 2. APPLICATION... 3 2.1 HIGH Liquid Level Alarm 2.2 LOW Liquid Level Alarm 3. INSTALLATION...

More information

Installation Instructions. The SEC-L is a gas pressure proving system with water and electric isolation, gas detection and ventilation interlock.

Installation Instructions. The SEC-L is a gas pressure proving system with water and electric isolation, gas detection and ventilation interlock. V3.3 Installation Instructions The SEC-L is a gas pressure proving system with water and electric isolation, gas detection and ventilation interlock. The system will perform a down stream integrity check

More information

Please read this sheet as it contains important information

Please read this sheet as it contains important information Important Please read this sheet as it contains important information Before commencing installation please familiarise yourself to the equipment by reading the comprehensive installation instructions.

More information

MPT Electric Fire Pump Controller

MPT Electric Fire Pump Controller Setup and Operating Instructions MPT Electric Fire Pump Controller This manual provides general information, installation, operation, maintenance, and system setup information for Metron MPT Electric Fire

More information

Advances in Load Center Technologies and End-of-Life GFCI Breaker Limitations

Advances in Load Center Technologies and End-of-Life GFCI Breaker Limitations Advances in Load Center Technologies and End-of-Life GFCI Breaker Limitations Advances in Load Center Technologies and End-of-Life GFCI Breaker Limitations Rob Spragis, Director of Business Development

More information

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions HZM-Series-Class I, Div 2 Battery Unit HZM-Series-Class I, Div 2 Battery Unit Instalation instructions IMPORTANT SAFEGUARDS 1 4 5 6 7 13 When using electrical equipment, basic safety precautions should

More information

How to keep you, your family, and your possessions safe usa.siemens.com/circuitbreakers

How to keep you, your family, and your possessions safe usa.siemens.com/circuitbreakers AFCI and GFCI Homeowner s Guide How to keep you, your family, and your possessions safe usa.siemens.com/circuitbreakers Congratulations on the purchase of your new home. This guide will help you understand

More information

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL. Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL www.aquaticsentry.com TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 3 2. APPLICATION... 3 2.1 HIGH AND LOW LEVEL ALARM 2.2 PUMP DOWN CONTROLLER 2.3

More information

Product Data Sheet. Merlin GDP2. Gas Safety Products. Merlin GDP2. Installation, operating and maintenance 23/08/2016. S&S Northern Ltd 1

Product Data Sheet. Merlin GDP2. Gas Safety Products. Merlin GDP2. Installation, operating and maintenance 23/08/2016. S&S Northern Ltd 1 Gas Safety Products Merlin GDP2 Installation, operating and maintenance 23/08/2016 S&S Northern Ltd 1 Table of contents 1 General information... 3 2 Installation... 3 2.1 Panel Mounting..... 3 2.2 Mains

More information

Racal-Guardall. Countess. User Instructions. Countess

Racal-Guardall. Countess. User Instructions. Countess Racal-Guardall Countess User Instructions Countess INCORRECT ACCESS CODES If three incorrect access codes are entered within five minutes a tamper fault will be generated. 1. SETTING FULL SYSTEM Enter

More information

Extra Heavy Duty Industrial & Hospital Grade GFCI Receptacles

Extra Heavy Duty Industrial & Hospital Grade GFCI Receptacles Extra Heavy Duty Industrial & Hospital Grade GFCI Receptacles and Weather Resistant GFR5362SGI 10kA Short Circuit Current Rating Limits improper access to energized contacts Exclusive patented tamper-resistant

More information

Operating Instructions

Operating Instructions Operating Instructions Electronic timer H818 E To prevent accidents and machine damage, read these instructions before installation or use. UV M.-Nr. 03 359 590 2 Operation Important To operate the combi-oven

More information

Afci TR Duplex 20A 125V Iv. Features amperage rating. Dimensions and Weight. Descriptions

Afci TR Duplex 20A 125V Iv. Features amperage rating. Dimensions and Weight. Descriptions 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 TRAFCI20V Afci TR Duplex 20A 125V Iv Eaton Wiring Devices Catalog Number Manufacturer Description Weight per unit Product

More information

Boiler Room Control THE MERLIN RANGE GAS DETECTION EQUIPMENT ENGINEERED TO DELIVER EXCEPTIONAL LEVELS OF SAFETY

Boiler Room Control THE MERLIN RANGE GAS DETECTION EQUIPMENT ENGINEERED TO DELIVER EXCEPTIONAL LEVELS OF SAFETY Boiler Room Control THE MERLIN RANGE GAS DETECTION EQUIPMENT ENGINEERED TO DELIVER EXCEPTIONAL LEVELS OF SAFETY 2 THE MERLIN RANGE AMERICAN GAS SAFETY Gas detection and controls for boiler house applications

More information

AFCI. RECEPTACLEFAQs. What is an arc fault? What causes arc faults?

AFCI. RECEPTACLEFAQs. What is an arc fault? What causes arc faults? RECEPTACLEFAQs AFCI 1 What is an arc fault? UL provides a definition for an arc fault in UL 1699 (Standard for Safety Arc Fault Circuit Interrupters). It is an unintentional arcing condition in a circuit.

More information

EXTINGUISHING AGENT RELEASE MODULE

EXTINGUISHING AGENT RELEASE MODULE EXTINGUISHING AGENT RELEASE MODULE Operation, Installation & Programming Manual Revision 3.00 Distributors For: 18-20 Brookhollow Ave telephone 02 8850 2888 www.firesense.com.au Baulkham Hills NSW 2153

More information

RV Safety Alarms Education Test

RV Safety Alarms Education Test RV Safety Alarms Education Test This Educational Test is designed to improve the knowledge of RV technicians as to the history and performance of safety alarms installed in RV s. Section: LP Gas Alarms

More information

Combination Type AFCI

Combination Type AFCI Combination Type AFCI Evolution of the Arc Fault Circuit Interrupter www.usa.siemens.com/afci 2 Alarming Statistics According to the U.S. Fire Administration (USFA), an estimated 67,800 fires, 485 deaths,

More information

M800, M800iD Plus, M1000 and M3000. User's Guide

M800, M800iD Plus, M1000 and M3000. User's Guide M800, M800iD Plus, M1000 and M3000 User's Guide Cooper Security Limited 2005 Every effort has been made to ensure that the contents of this book are correct. However, neither the authors nor Cooper Security

More information

NXM2G Installation and Operating Manual

NXM2G Installation and Operating Manual NXM2G-1001 MARCH 26, 2014 NXM2G Installation and Operating Manual (-1 UL version shown) 40VG This manual must be affixed on or adjacent to the boiler or kept with boiler operating manual or other information.

More information

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions 3LERHZ Series Class I, Div 2 Combo Unit Installation instructions 3LERHZ Series Class I, Div 2 Combo Unit IMPORTANT SAFEGUARDS 1 3 When using electrical equipment, basic safety precautions should always

More information

WHITE PAPER: ARC FAULT CIRCUIT INTERRUPTERS EXPANDING HOME SAFETY

WHITE PAPER: ARC FAULT CIRCUIT INTERRUPTERS EXPANDING HOME SAFETY WHITE PAPER: ARC FAULT CIRCUIT INTERRUPTERS EXPANDING HOME SAFETY Expanding Home Safety Page 2 INTRODUCTION Smoke alarms, fire extinguishers, emergency escape ladders these are all proven methods for making

More information

Powerohm Resistors Digital HRG System

Powerohm Resistors Digital HRG System Installation and Operating Instructions Powerohm Resistors Digital HRG System This manual provides general information, installation, operation, maintenance, and system setup information for the Powerohm

More information

2200 and 2200L ALARM CONTROL SYSTEMS

2200 and 2200L ALARM CONTROL SYSTEMS 2200 and 2200L ALARM CONTROL SYSTEMS OPERATING INSTRUCTIONS MODELS: 2200 (fitted software 3.4 or later) 2200L (fitted software 3.9L or later) Castle Care-Tech Ltd. 2200/2200L Alarm System Operating Manual

More information

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014 January 16, 2014 Release Control Panel 290a 1. Description The Viking VFR400 is a microprocessor based releasing control panel for use on preaction, deluge, Surefire, Firecycle multicycle sprinkler systems,

More information

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps TT-1023 1/97 INSTALLATION INSTRUCTIONS Original Issue Date: 2/94 Model: 6-2000 kw Market: Industrial Subject: Flush- or Surface-Mount Remote Annunciator Kits PA-293991 and PA-293991-SD The remote annunciator

More information

TS5160. Installation & User Guide. Compatible Equipment. CPA6 0M - Output Module Loudspeaker DC54/58 - Digital Communicators (Stand Alone Only)

TS5160. Installation & User Guide. Compatible Equipment. CPA6 0M - Output Module Loudspeaker DC54/58 - Digital Communicators (Stand Alone Only) Installation & User Guide Compatible Equipment CPA6 0M - Output Module 9040 - Loudspeaker DC54/58 - Digital Communicators (Stand Alone Only) 496527 Issue A 1 of 16 TS5160 Overview Introduction Specification

More information

Ammonia Detection System Codes and Design Specifications

Ammonia Detection System Codes and Design Specifications Ammonia Detection System Codes and Design Specifications January 15, 2018 Revision 6 Ammonia detection system codes and design specifications Following is a discussion of ammonia detection system design

More information

OJD ITB No Attachment E Duress Alarm Equipment Specifications

OJD ITB No Attachment E Duress Alarm Equipment Specifications Duress Alarm Equipment Specifications PART 1 GENERAL 1.1 SECTION INCLUDES A. Duress devices. B. Alarm control panel. C. Signaling devices. 1.2 REFERENCE STANDARDS A. NFPA 70 - National Electrical Code;

More information

M2500 Engine Controller Installation Manual

M2500 Engine Controller Installation Manual M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...

More information

CONDENSATE MANAGEMENT SYSTEMS

CONDENSATE MANAGEMENT SYSTEMS CONDENSATE MANAGEMENT SYSTEMS AG-1100+ Magnetic Float Switch System for Metal Secondary Drain Pans The AG-1100+ is incredibly easy to install. It can be mounted to the drain pan in 10 seconds or less.

More information

KFP-CF Series Operation Manual

KFP-CF Series Operation Manual KFP-CF Series Operation Manual P/N 501-415103-2-31 REV 03.10 ISS 13NOV13 Copyright Trademarks and patents Manufacturer Version Certification European Union directives Contact information 2013 UTC Fire

More information

SETTING UP GUIDE. This Handbook is for the Installer. You must read these instructions prior to installing and commissioning the Credanet system.

SETTING UP GUIDE. This Handbook is for the Installer. You must read these instructions prior to installing and commissioning the Credanet system. SETTING UP GUIDE Controller Heating System Credanet II This Handbook is for the Installer You must read these instructions prior to installing and commissioning the Credanet system. Page 1 Credanet II

More information

Job No A. Submit the following equipment, materials and products, including all fittings and accessories:

Job No A. Submit the following equipment, materials and products, including all fittings and accessories: SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification

More information

Doc. No Part No Rev. U * T*

Doc. No Part No Rev. U * T* Doc. No. 430545 Part No. 579-357 Rev. U *0579357T* Blank Page- Back of Front Cover Copyrights and Trademarks 2005-2018 Johnson Controls. All rights reserved. Specifications and other information shown

More information

Instruction Bulletin

Instruction Bulletin Instruction Bulletin 435-54-26A 9/99 Monroe, NC, USA MODEL 98 Digital Temperature Controller For Medium Voltage Transformers Class 3, 4 Retain for future use. NOTICE Read these instructions carefully and

More information

A. This Section provides requirements and specifications for wiring devices, wiring device accessories, and wiring device assemblies including:

A. This Section provides requirements and specifications for wiring devices, wiring device accessories, and wiring device assemblies including: SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. This Section provides requirements and specifications for wiring devices, wiring device accessories, and wiring device assemblies including:

More information

21-light Remote Annunciator. Owner s Manual

21-light Remote Annunciator. Owner s Manual 21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With

More information

Gas Safety Products. Installation, operating and maintenance. Merlin 1000VW+ Gas Interlock, Gas Proving, Electric & Water Isolation System

Gas Safety Products. Installation, operating and maintenance. Merlin 1000VW+ Gas Interlock, Gas Proving, Electric & Water Isolation System Gas Safety Products Merlin 1000VW+ Gas Interlock, Gas Proving, Electric & Water Isolation System Installation, operating and maintenance Read these instructions carefully before operating or servicing

More information

TECHNICAL BROCHURE BCALARM R4. Indoor and Outdoor Panels and Accessories

TECHNICAL BROCHURE BCALARM R4. Indoor and Outdoor Panels and Accessories TECHNICAL BROCHURE BCALARM R4 Indoor and Outdoor Panels and Accessories FEATURES Indoor and Outdoor alarm panels for sump, effluent and wastewater systems as well as test panel for troubleshooting. Use

More information

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass Project: Customer: Engineer: Pump Manufacturer: Submittal Document Model VPS Pressure Limiting (VFD) with Soft Start Bypass Contents: Data Sheets Dimensional Data Wiring Schematics Field Connections Note:

More information

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G E SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF DATE: 11/13/06 2/1/07 1 Copyright, E, Inc. E 1. ENERAL...4 1.1 Scope Of Work... 4 1.2 Codes and Standards... 4 2. PRODUCTS...5

More information

Caliber Series LED Edgelit Exit Sign EXPORT AC Only or Emergency Operation READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Caliber Series LED Edgelit Exit Sign EXPORT AC Only or Emergency Operation READ AND FOLLOW ALL SAFETY INSTRUCTIONS Caliber Series LED Edgelit Exit Sign EXPORT AC Only or Emergency Operation INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should

More information

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc MASTER JOCKEY PUMP CONTROLLER Model JPCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page 4 Model

More information

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup NetworX Series NX-8 Commercial Fire Panel Installation and Startup 2004 GE Security All rights reserved. Printed in the United States of America. These instructions do not purport to cover all details

More information

Owner's Manual TABLE OF CONTENTS

Owner's Manual TABLE OF CONTENTS 40MAQ High Wall Ductless System Sizes 09 to 36 Owner's Manual TABLE OF CONTENTS PAGE A NOTE ABOUT SAFETY... 2 GENERAL... 2 PART NAMES... 3 FUNCTION BUTTONS... 4 DISPLAY PANELS... 5 REMOTE CONTROL... 6

More information

National Broadband Network. User Guide. Includes important information about your NBN equipment

National Broadband Network. User Guide. Includes important information about your NBN equipment National Broadband Network User Guide Includes important information about your NBN equipment 1 CONTENTS Quick start guide 4 Connecting the Network Termination Device to your own equipment 5 Maintaining

More information

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY SECTION 22 11 23.13 DOMESTIC WATER PRESSURE BOOSTING PART 1 - GENERAL 1.1 SUMMARY A. Where utility water pressure cannot adequately meet the pressure requirements of the domestic water systems and where

More information

Maintenance Manual PC6010. WARNING This manual contains information on limitations regarding product use and function

Maintenance Manual PC6010. WARNING This manual contains information on limitations regarding product use and function WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully

More information

918TS Manual 1/26/09-1 -

918TS Manual 1/26/09-1 - 918TS Manual 1/26/09-1 - Table Of Contents: FEATURES...3 INSTALLATION...5 POWERING ON / INITIAL SETUP...5 SETTING DELIEVRY PRESSSURE... 7 OPTIONS & SETTINGS...8 ALARM NOTIFICATION TABLE...10-2 - FEATURES

More information

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels Installation and user manual for the FX range of fire panels 1, 2, 4 and 8 zone panels Contents Panel installation 3 Panel connections 3 Wiring connection drawings 4 Panel facilities 6 Installation check

More information

Beacon 800 Gas Monitor Operator s Manual

Beacon 800 Gas Monitor Operator s Manual Beacon 800 Gas Monitor Operator s Manual Part Number: 71-0037RK Revision: F Released: 4/18/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by us to be

More information

Water Detection Controllers

Water Detection Controllers Page 1 of 5 Water Detection Controllers Features: Benefit: LED Status of leak status VFC output Audible alarm Auto or manual reset alarm output Uses an isolated AC signal which prevents oxidation or erosion

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TT-46 8/05 INSTALLATION INSTRUCTIONS Original Issue Date: 8/05 Model: Automatic Transfer Switches equipped with MPAC 500 Controls Market: ATS Subject: External Alarm Module (EAM) Kit GM38795-KP Introduction

More information

Drawing Submittal Package

Drawing Submittal Package Project: Customer: Engineer: Pump Manufacturer: Drawing Submittal Package Model GPL + GLU Limited Service Full Voltage Across the Line Start Electric Pump Controller with Automatic Power Transfer Switch

More information

Mounting Plate ADA/HOSPITAL SIGNALING DEVICES 14-8 FEATURES. > Momentary switch push button > Stainless steel faceplate

Mounting Plate ADA/HOSPITAL SIGNALING DEVICES 14-8 FEATURES. > Momentary switch push button > Stainless steel faceplate Mounting Plate 147-10 > Momentary switch push button > Stainless steel faceplate The Edwards Cat. No. 147-10 Mounting Plate when used with the catalog series 620 Push Buttons (page 10-9) forms a convenient

More information

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. American Gas Safety LLC 1 05/10/2016

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. American Gas Safety LLC 1 05/10/2016 Gas Safety Products Installation, operating and maintenance 05/10/2016 American Gas Safety LLC 1 Table of contents 1 General information... 3 2 Installation... 3 2.1 Panel Mounting.... 3 2.2 Mains Supply...

More information

REPORT ON DISCUSSIONS DURING UL MEETINGS WITH ELECTRICAL INSPECTORS AT THE 2003 IAEI 75 th JUBILEE MEETING

REPORT ON DISCUSSIONS DURING UL MEETINGS WITH ELECTRICAL INSPECTORS AT THE 2003 IAEI 75 th JUBILEE MEETING REPORT ON DISCUSSIONS DURING UL MEETINGS WITH ELECTRICAL INSPECTORS AT THE IAEI 75 th JUBILEE MEETING September 1, 2004 TO: SUBJECT: Attendees of Underwriters Laboratories Inc. Meetings with Electrical

More information

LDRA6 ARCHITECT AND ENGINEER SPECIFICATIONS. RLE TECHNOLOGIES Rev

LDRA6 ARCHITECT AND ENGINEER SPECIFICATIONS. RLE TECHNOLOGIES Rev LDRA6 ARCHITECT AND ENGINEER SPECIFICATIONS RLE TECHNOLOGIES Rev 1.0 110062 1. GENERAL SPECIFICATION 1.1 The contractor shall provide RLE Technologies SeaHawk LDRA6 Multi-Functional Alarm Panel (hereinafter

More information

WLS900 Wireless Security System. Table of Contents. Your installing company is, Name: Address: Phone: Your monitoring station is, Name: Phone:

WLS900 Wireless Security System. Table of Contents. Your installing company is, Name: Address: Phone: Your monitoring station is, Name: Phone: Table of Contents WLS900 Wireless Security System 1 Introduction 2 2 Using the Keypad 3 3 Arming the System 4 3A - Arming Levels; 4 3B - Arming the System in the Away Mode 4 3C - Improper Arming Warning

More information

CAREL CONTROLLER. Programming Instructions HOW TO CHANGE LEVEL 1 CONTROL SETTINGS HOW TO CHANGE LEVEL 2 CONTROL SETTINGS

CAREL CONTROLLER. Programming Instructions HOW TO CHANGE LEVEL 1 CONTROL SETTINGS HOW TO CHANGE LEVEL 2 CONTROL SETTINGS CAREL CONTROLLER Programming Instructions The Carel controller has a two-level menu system for programming the operation of the case. Level 1 program settings are the most frequently accessed parameters.

More information

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 SPEC WRITER NOTE: Use this section only for NCA projects. Delete between //--// if not applicable to project. Also, delete any other item or paragraph

More information

Type of Fire Alarm Control Panel: System is: Existing OR New If new, provide Electrical Permit Number:

Type of Fire Alarm Control Panel: System is: Existing OR New If new, provide Electrical Permit Number: DATE OF SUBMISSION TO: Department of Licenses and Inspections Commercial and Industrial Fire Inspection Unit 990 Spring Garden Street, 3 rd Floor, Philadelphia, PA 19123 AP# CITY OF PHILADELPHIA FIRE ALARM

More information

Network Maintenance: Alarm and Control for Network Elements

Network Maintenance: Alarm and Control for Network Elements Network Maintenance: Preface...Preface-1 1. Introduction...1-1 1.1 Relationship to other Bellcore Technical Documents...1-1 1.2 Purpose of Issue 1 and Changes from TR-NWT-000474...1-2 1.3 Scope of Document...1-2

More information

50A Integrated Furnace Control

50A Integrated Furnace Control Goodman White-Rodgers 0130F00005 PCBBF110 PCBBF123 50A55-743 0130F00005S PCBBF110S PCBBF123S 50A55-289 B1809926 PCBBF112 50T55-289 B1809926S PCBBF112S 50A55-743 Integrated Furnace Control INSTALLATION

More information

Flopurge TS. Operation Manual

Flopurge TS. Operation Manual Flopurge TS Operation Manual Part Number 079-0204 Spectron Gas Control Systems United Kingdom Unit 4, Herald Court, University of Warwick Science Park, Coventry, CV4 7EZ +44 (0)24 7641 6234 sales@spectron-gcs.com

More information

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers Maximizing Critical Sample Protection and Storage Innovative Features and Rewarding Benefits Features Advantage Benefit Refrigeration

More information

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description.

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description. Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description The TYCO RAPID RESPONSE Model RCP-1 Residential

More information

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU with Automatic Power Transfer Switch Contents: NOTE: The drawings included in this package are for controllers covered under our standard

More information