AUTOGUARD Hubbell Self Test Ground Fault Circuit Interrupters. More innovation. More protection. More safety.
|
|
- Frederick McDonald
- 5 years ago
- Views:
Transcription
1 AUTOGUARD Hubbell Self Test Ground Fault Circuit Interrupters. More innovation. More protection. More safety. The GFCI that Tests Itself! You may forget, but Hubbell AutoGuard GFCI won't. Nothing delivers like Hubbell GFCI Solutions
2 AUTOGUARD Self Test Ground Fault Receptacle with Diagnostic Design THE GFCI THAT TESTS ITSELF! There s an old expression, when you need to get something done, you often have do it yourself. This certainly applies when you consider the world of a ground fault receptacle. After all, ground fault receptacles rely entirely on the end user to test the functionality of the unit. Unless the unit is tested as advised by the manufacturer, this evaluation is not being done. When was the last time you pressed the test button on your ground fault receptacle in your facility or at home? How about that busy one in the bathroom that provides safety when using the ever-popular hair dryer or perhaps the GFR that powers the water pump on that backyard swimming pool your kids just cooled off in? Don t forget that workshop area you like to play in with those creative power tools. Background All of today s GFCI receptacle manufacturers rely entirely on the end user to test the functionality of the unit. End users are required to execute a test & reset function to verify that the product is performing correctly. This test should be conducted one time per month at a minimum. Operation of the test button provides critical information relating to the functionality of the device and its ability to provide people protection. Despite the once a month requirement, most users do not test their ground fault receptacles at any point in time. Self Test Technology The new Hubbell self-test ground fault receptacle directly addresses this concern. An internally generated simulated ground fault will enable the GFCI to check for proper operation of the unit every 60 seconds. This provision is a major feature that surpasses any existing design on the market. The validation test for GFCI functionality can now be performed automatically. This diagnostic feature literally tests & monitors itself by way of the electronic design. With this feature, the ability to provide people protection can now be verified on a continuous basis. This is a significant contrast when comparing the one time per month recommendation that is suggested today. Manual Whole System Test The AUTOGUARD design incorporates a unique full system test function. The Hubbell GFCI when tested actually induces a simulated ground fault leakage current to the printed circuit board. This in turn causes the mechanical system to react based on the action of the solenoid. The entire mechanical and electronic GFCI system is reviewed for functionality. This comprehensive approach to testing is a Hubbell exclusive.
3 The GFCI That Tests Itself. You May Forget, But the Hubbell AUTOGUARD GFCI Won't! Excellent Vibration Resistance Manufacturing Meets UL943 performance requirements by design, not by lockout Mobile Power Power Indicator When Steady ON School Laboratories Over sized silver contacts for high performance switching Exceptional Noise Filtering to avoid nuisance tripping Recreation High impact chemical resistant nylon construction Physical Therapy
4 Hubbell, Your Safety Solution Provider. More innovation. More protection. More safety. Whole System Test Functionality Meets new UL 943 Requirement when Reverse Wired No power to face Water Treatment 10 ka Short Circuit Rating Flashing Red Immediate Indication if Unit has lost GFCI Protection Function - Diagnostic Feature - Continuous Electronic Sensing & Testing - Meets New UL 943 Requirement for end of use" indication Medical Laboratory Ground Fault Indicator When Red Steady ON Superior Surge Immunity Bathroom Conformal Coated Glass Fiber PCB for Corrosion & Moisture Resistance Hospital The Hubbell Exclusive Self Test GFCI is a comprehensive approach to testing. Reverse Wire Safety Feature assures unit will not be able to reset under a reversed wiring condition. Meets the Surge Withstand Requirement without relying on a lock-out mode. Spa/Jacuzzi
5 More innovation. More protection. More safety. The HUBBELL AUTOGUARD Safety Advantage Reverse Wire Safety Feature The Hubbell GFR will not have power at both the face and downstream if the line and load are reverse wired. Additionally, the unit will not be able to reset under a reversed wiring condition. Typically if the line and load are reversed, there will be power at the face and the end user would assume there is ground fault protection at the point of use. Surge Withstand Underwriters Laboratories requires all ground fault receptacles to meet a 6kV, 3kA surge test without compromising the people protection functionality of the unit. If a unit cannot meet this performance requirement, it must shut down and become totally inoperable. Hubbell meets the surge withstand requirement by design without relying on a non-operational lock out mode to meet the test. Hubbell opted to build a more robust device by incorporating a heavy duty Metal Oxide Varistors (MOV) into the product. This MOV was specifically designed into the Hubbell GFCI receptacle with the intention of passing the UL 6 kv, 3kA surge immunity test while continuing to provide power and protection to the face and downstream loads. Three provisions for providing protection Continuous electronic sensing & testing, utilizing diagnostic software immediate indication if unit has lost the ability to protect Traditional testing mode by manually operating the test and reset buttons Traditional auto-sensing mode for immediate interruption for a ground fault condition 10,000 Amp Short Circuit Rating AUTOGUARD was designed to withstand the stringent applications where a potential for high current short circuit conditions exist such as industrial power centers, disconnects and motor centers. The Hubbell Exclusive Self Test GFCI is a comprehensive approach to testing. Reverse Wire Safety Feature assures unit will not be able to reset under a reversed wiring condition. Meets UL943 performance requirements by design, not by lockout Over 115 YEARS OF DESIGN INNOVATION & CUSTOMER SOLUTION GFCI New UL GFCI with LED Functionality 2004 AUTOGUARD Self Test GFCI 2005
6 AUTOGUARD Self Test Ground Fault Receptacle with Diagnostic Design Commercial Color 15A 20A Brown GFR5252ST GFR5352ST Ivory GFR5252IST GFR5352IST White GFR5252WST GFR5352WST Gray GFR5252GYST GFR5352GYST Black GFR5252BKST GFR5352BKST Red GFR5252RST GFR5352RST Office White GFR5252OWST GFR5352OWST Almond GFR5252ALST GFR5352ALST Faceless Color 15A 20A Brown GFR5350ST Ivory GFR5350IST White GFR5350WST Gray GFR5350GYST Black GFR5350BKST Specifications Trip Level 4 6 ma Trip Time.025 sec Frequency 60Hz Voltage 120V AC +10% - 15% Max Humidity 95% Maximum Interrupting Capacity 10,000 Amps Operating Temperature -35 C to +66 C (-30 F to +150 F) Codes & Standards Meets UL 943 Class A GFCIs and UL 498 for Receptacles Complies to NEC, CEC & OSHA UL File E-41978, CSA File LR Dimmensions in. (mm.) Hospital Grade Color 15A 20A Brown GFR8200HST GFR8300HST Ivory GFR8200HIST GFR8300HIST White GFR8200HWST GFR8300HWST Gray GFR8200HGYST GFR8300HGYST Black GFR8200HBKST GFR8300HBKST Red GFR8200HRST GFR8300HRST Office White GFR8200HOWST GFR8300HOWST Almond GFR8200HALST GFR8300HALST Note: GFCI type receptacles should not be used in critical care patient areas or for electrical life support equipment applications because of the possibility of power interruption. Also from the Hubbell GFCI Offering... GFR5352IST GFR5350BKST GFR8200HWST Standard GFCI Receptacles GFCI Receptacles with LED Indicator Portable Plugs and Line Cords Multiple Outlet Portable GFCI GFCI Plugs and Modules Heavy Duty Industrial Grade Receptacles Heavy Duty Hospital Grade Receptacles Hard Wired and Portable 30A GFCI Please visit for more information. Printed In U.S.A. Specifications subject to change without notice. Registered trademark of Hubbell Incorporated H5185 Hubbell Incorporated (Delaware) 185 Plains Road Milford, CT (203) FAX (800)
2015 New GFCI Requirements
2015 New GFCI Requirements Why are GFCI receptacles changing in 2015? The Underwriters Laboratory Standard (UL 943) for GFCI will require manufacturers to include a new function for all ground fault receptacles
More informationArrow Hart hospital grade self-test GFCI receptacles
Description 2-pole, 3-wire grounding 15A, 125V/AC; 20A, 125V/AC NEMA 5-15, 5-20 Design features Performs periodic self-tests to ensure integrity of GFCI protection. Meets and exceeds 10 ka short circuit
More informationAF/GF dual-purpose receptacles
Eaton Wiring Devices OBC AF/GF dual-purpose receptacles AF/GF dual-purpose receptacles Arc fault and ground fault protection in one device In Stock July 2016! Eaton Wiring Devices OBC AF/GF dual-purpose
More informationGE Industrial Solutions. Residential Electronic Circuit Interrupters
GE Industrial Solutions Residential Electronic Circuit Interrupters Dual Function Circuit Interrupter (DFCI) Provides ground fault and arc fault circuit protection in one unit The 2014 National Electric
More informationAfci TR Duplex 20A 125V La. Features amperage rating 20. Dimensions and Weight Width 3.3. Long Description
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 TRAFCI20LA Afci TR Duplex 20A 125V La Eaton Wiring Devices Catalog Number Manufacturer Weight per unit Product Category
More informationAfci TR Duplex 20A 125V Iv. Features amperage rating. Dimensions and Weight. Descriptions
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 TRAFCI20V Afci TR Duplex 20A 125V Iv Eaton Wiring Devices Catalog Number Manufacturer Description Weight per unit Product
More informationIntroducing a revolutionary new line of 15 and 20 amp devices engineered for fast and easy installation
Sold by: http://www.twacomm.com Toll Free: (877) 389-0000 Commercial / Industrial Introducing a revolutionary new line of 15 and 20 amp devices engineered for fast and easy installation Introduction lev-lok
More informationExtra Heavy Duty Industrial & Hospital Grade GFCI Receptacles
Extra Heavy Duty Industrial & Hospital Grade GFCI Receptacles and Weather Resistant GFR5362SGI 10kA Short Circuit Current Rating Limits improper access to energized contacts Exclusive patented tamper-resistant
More informationArrow Hart specification grade GFCI receptacles
Technical Data Description 2-pole, 3-wire grounding 15A, 125V/AC 20A, 125V/AC SGF20 TAMPER RESISTANT Design features Performs periodic self-tests to ensure integrity of GFCI protection Visual trip indicator
More informationGfci Self Test Duplex 20A 125V WH
SGF20W Gfci Self Test Duplex 20A 125V WH Eaton Wiring Devices Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Description Long Description Product Type special features
More informationSERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION
R SERIES 35-61 24 VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay F-35-61 August 2015 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge
More informationGFCI Products Buying Guide
GFCI Products Buying Guide A Ground Fault Circuit Interrupter (GFCI) is an important safety device to have in a home to help protect people from electrical shocks due to hazardous ground faults. Ground
More informationMORE PROTECTION. MORE FUNCTIONALITY. IN MORE ENVIRONMENTS.
PASS & SEYMOUR SELF-TEST GFCI RECEPTACLES REINVENTING SAFETY ALL AROUND MORE PROTECTION. MORE FUNCTIONALITY. IN MORE ENVIRONMENTS. 2 SAFETY IS OUR CODE When we invented the first GFCI receptacle, our goal
More informationCIRCUITPRO Self Test Ground Fault Receptacles
IRUITPRO Self Test Technology 1st introduced by ryant over 10 years ago! self test monitoring now required in 2015 UL 943 GFI Safety Tamper- Resistant Hospital Grade ombo Switch/GFI udible ryant Self Test
More informationSERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)
R SERIES 35-70 120 VAC Microprocessor-Based Direct Spark Ignition Control F-35-70 November 2015 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge and inter-purge timings
More informationSERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION
R SERIES 35-703 120 VAC Microprocessor-Based Intermittent Pilot Ignition Control F-35-703 July 2016 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge and inter-purge timings
More informationElectrical Safety Program.
University of North Carolina Wilmington Environmental Health & Safety Workplace Safety Electrical Safety Program GENERAL The UNCW Environmental Health & Safety Department (EH&S) is authorized by UNCW Policy
More informationCONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION
AIR SERIES SYSTEM INSTALLATION MANUAL CONTENTS CONSIDERATIONS General Plumbing Component Connection 2 2 2 ILLUSTRATION Control System 3 CONFIGURATION Voltage Verification 4 CONNECTION Component Connection
More informationHow to keep you, your family, and your possessions safe usa.siemens.com/circuitbreakers
AFCI and GFCI Homeowner s Guide How to keep you, your family, and your possessions safe usa.siemens.com/circuitbreakers Congratulations on the purchase of your new home. This guide will help you understand
More informationLC3000 Level Controller Installation and Maintenance Instructions
4025550/12 IM-P402-36 AB Issue 12 LC3000 Level Controller Installation and Maintenance Instructions 1. General safety information LC3000 NORM ALARM TEST 2. General product information 3. Installation 4.
More informationSECTION (16140) - WIRING DEVICES
SECTION 26 27 26 (16140) - WIRING DEVICES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Receptacles, Connectors, Switches, and Finish Plates. B. Related Sections: 1. Section 00 31 13.43 (00370) -
More informationCombination Type AFCI
Combination Type AFCI Evolution of the Arc Fault Circuit Interrupter www.usa.siemens.com/afci 2 Alarming Statistics According to the U.S. Fire Administration (USFA), an estimated 67,800 fires, 485 deaths,
More informationElectrical Safety Through Design. Mersen EP formerly Ferraz Shawmut
Electrical Safety Through Design Mersen EP formerly Ferraz Shawmut Agenda Who is Mersen? Selective Coordination Code Requirements Coordination Made Easy Mitigating Arc Flash Energy on Transformer Secondary
More informationELECTRONIC FLAME SUPERVISION MULTI-BURNER
MULTI-BURNER MODEL: SENS-A-FLAME II Revision: 0 7112 DESCRIPTION Model 7112 Sens-A-Flame II is a second generation solid-state programmable combustion safeguard for supervising multiple burner ovens, furnaces,
More informationSERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS
SERIES 35-65 24 VAC Microprocessor-Based Hot Surface Ignition Control F-35-65 August 2015 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge and inter-purge timings* 120/240
More informationGuide Specification Model CTG Automatic Transfer Switch
Guide Specification Model CTG Automatic Transfer Switch PART 1 GENERAL 1.1 Scope A. It is the intent of this specification to secure a transfer switch that has been prototype tested, factory built, production
More informationSECTION AUTOMATIC TRANSFER SWITCHES
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 SPEC WRITER NOTE: Use this section only for NCA projects. Delete between //--// if not applicable to project. Also, delete any other item or paragraph
More informationSECTION ISOLATED POWER SYSTEMS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 20 11 ISOLATED POWER SYSTEMS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also, delete any other item or paragraph not applicable to
More informationOperation and use. Functions and characteristics
Operation and use Function Vigirex relays measure the earth-leakage current in an electrical installation via their associated toroids. Vigirex relays may be used for: b residual-current protection (RH10,
More informationVeterinary Patient Warming System Controller User Manual
Veterinary Patient Warming System Controller User Manual Contents Introduction... 3 Indications for use... 3 Contraindications... 3 Warnings... 3 Precautions... 4 Proper Use and Maintenance... 5 Initial
More information* Consult factory on conditions for approval acceptability
6 Introduction Guide Guide to Power Protection How various power protection devices work How to use power protection devices 39 6600 Series Sub-miniature bimetal thermostat 8-PIN DIP package configuration
More informationSoft Start Series MP700 Solid State, Reduced Voltage
Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s
More informationPortable CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions
Portable CNA-Series - Large Industrial Heaters Heavy duty industrial cart options simplify moving heater to various locations 36-72 kw (122,800-245,600 BTUs) Certified Lead-Free Design New & Improved Pressure
More information17 TH APRIL 2017 Switch Board Monitoring Protecting Switchboard. Courtesy of ABB. Paul Lee
17 TH APRIL Switch Board Monitoring Protecting Switchboard Courtesy of ABB. www.fengshengelectric.com.sg Paul Lee Agenda 1. Introduction 2. IEC 61439 3. Why Switchboard Monitoring 4. Switchboard Monitoring
More informationB. Shop Drawings: List of legends and description of materials and process used for premarking wall plates.
SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationElectrical Safety Program
Electrical Safety Program Developed by: The Office of Environmental Health and Safety June, 2010 Table of Contents Introduction 3 Scope..3 Definitions.3-5 CSU Electrical Shop...5 Responsibilities.5-6 Employees.....5
More information9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc.
Chapter 1 GROUNDING AND BONDING 1 Proper grounding practices protect people from the hazards of electric shock and ensure the correct operation of overcurrent protection devices. Grounding is the intentional
More informationDRAFT INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information
INSTALLATION INSTRUCTIONS Solid-State Series!! NOTE!! Covers the following models: " CS6100 - CS7100 " CS6200 - CS9200 " CS6220 - CS9220 " CS6230 - CS9230 " CS6500 - CS7500 " CS6330 - CS9300 " CS9400 -
More informationBE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD.
BE1-50/51B SELF POWERED TIME OVERCURRENT RELAY RETROFIT KITS BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD. BE1-50/51B, CO Retrofits BE1-50/51B,
More informationAcross-the-Line SERIES MP300 Combined Manual and Automatic
Across-the-Line SERIES MP300 Combined Manual and Automatic Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for Centrifugal Fire Pumps
More information50A Integrated Furnace Control
Goodman White-Rodgers 0130F00005 PCBBF110 PCBBF123 50A55-743 0130F00005S PCBBF110S PCBBF123S 50A55-289 B1809926 PCBBF112 50T55-289 B1809926S PCBBF112S 50A55-743 Integrated Furnace Control INSTALLATION
More informationSECTION K. Table of Contents. Wiring Device-Kellems. Heavy Duty Commercial GFCIs. Extra Heavy Duty Industrial GFCIs
SECTION K Table of Contents Extra Heavy Duty Industrial GFCIs Heavy Duty Commercial GFCIs Portable GFCI Products Product Page Hubbell Self Test GFCI Patented Technology K-2 Extra Heavy Duty Industrial
More informationA. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.
DIVISION 26 ELECTRICAL SECTION 26 27 26 PART 1 GENERAL 1.01 DESCRIPTION A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings. B. Specialty switches and outlets
More informationChapter 1 General...9 Article 100 Definitions...11 Article 100 Questions Article 110 Requirements for Electrical Installations...
Article 90 Introduction...1 90.1 Purpose of the NEC...1 90.2 Scope of the NEC...2 90.3 Code Arrangement...4 90.4 Enforcement...5 90.5 Mandatory Requirements and Explanatory Material...6 90.6 Formal Interpretations...6
More informationOperator: Save these instructions for future use!
50A66-743 Integrated Furnace Control Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
More informationCat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE
Cat. N STOP & GO automatic resetting 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat. N (s) : 4 062 88 / 4 062 89 CONTENTS PAGE 1. Description - Use... 1 2. Product
More informationHOW TO REPLACE ELECTRICAL OUTLET WITH GFCI E-BOOK
12 February, 2018 HOW TO REPLACE ELECTRICAL OUTLET WITH GFCI E-BOOK Document Filetype: PDF 186.04 KB 0 HOW TO REPLACE ELECTRICAL OUTLET WITH GFCI E-BOOK However, at the time of writing, March 2007, a GFCI
More informationSUGGESTED SPECIFICATION For Series 300 Manual Transfer Switches (3MTS)
SUGGESTED SPECIFICATION For Series 300 Manual Transfer Switches (3MTS) PART 1 GENERAL 1.01 Scope Furnish and install manual transfer switches (3MTS) with number of poles, amperage, voltage, and withstand
More informationSECTION AUTOMATIC TRANSFER SWITCHES
SECTION 26 36 23 AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationPortable C2N Series - Light Industrial Heaters Tankless Water Heating Solutions
Portable C2N Series - Light Industrial Heaters Heavy duty industrial cart options simplify moving heater to various locations 36-50 kw (122,800-170,600 BTUs) Variable Temp Heat Exchanger Pressure Drop
More informationPolySwitch TS600 Overcurrent Protection Devices
R PolySwitch TS600 Overcurrent Protection Devices New surface-mount products for overcurrent protection Raychem introduces the PolySwitch TS600 series to protect sensitive telecommunications equipment
More informationRead the other side, then complete the list below.
IS YOUR HOME SAFE? IS YOUR HOME SAFE? Read the other side, then complete the list below. Very important: DO NOT touch or try to fix electrical problems yourself! When you have completed the list, show
More information2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST
Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 637 Louisville,
More informationWHITE PAPER: ARC FAULT CIRCUIT INTERRUPTERS EXPANDING HOME SAFETY
WHITE PAPER: ARC FAULT CIRCUIT INTERRUPTERS EXPANDING HOME SAFETY Expanding Home Safety Page 2 INTRODUCTION Smoke alarms, fire extinguishers, emergency escape ladders these are all proven methods for making
More informationThe Safer Living Collection
The Safer Living Collection T H E S A F E R L I V I N G C O L L E C T I O N Improving Home Safety and Your Bottom Line We ve been leading advocates of electrical safety for over 100 years. Advancements
More informationGROUND FAULT PROTECTION METHODS & 2017 National Electric Code
GROUND FAULT PROTECTION METHODS 2014 & 2017 National Electric Code Ground Fault Protection Methods A Ground Fault Circuit Interrupter, or GFCI, is a device that functions to de-energize a circuit when
More informationSNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions
Pre-assembled skid system Back-to-Back heater models, SNA & SNAR High Flow Demand Safety Shower Applications 216-288 kw (737,000-983,000 BTUs) Temperature overshoot purge system NEMA 4 enclosure standard
More informationVariable Frequency Drive SERIES MP800 VFD
Metron Fire Pump Controls and Accessories Variable Frequency Drive SERIES MP800 VFD Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for
More informationI/O ZONE 560/583 AND OPERATION MANUAL
UPM I I/O ZONE 560/583 INSTALLATION AND OPERATION MANUAL 1 UNIT PROTECTION MODULE HARDWARE OPERATION IMPORTANT: This manual is for UPM board part numbers 8733 800 259. See controller label as shown in
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL
GE Digital Energy Power Quality INSTALLATION, OPERATION AND MAINTENANCE MANUAL GE TRANQUELL Enhanced Thermal Protection (ETP) Series Integrally Mounted Medium and High Exposure Surge Protective Devices
More informationResidual Current Devices
Residual devices F200 Series UL 1053 Residual devices F200 Series Residual Current Devices Description The F200 Series residual devices offer a wide range of product for all of your fault protection needs.
More informationREPORT ON DISCUSSIONS DURING UL MEETINGS WITH ELECTRICAL INSPECTORS AT THE 2003 IAEI 75 th JUBILEE MEETING
REPORT ON DISCUSSIONS DURING UL MEETINGS WITH ELECTRICAL INSPECTORS AT THE IAEI 75 th JUBILEE MEETING September 1, 2004 TO: SUBJECT: Attendees of Underwriters Laboratories Inc. Meetings with Electrical
More informationOperator: Save these instructions for future use!
031-01284-000/50A55-241 Integrated Furnace Control INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR
More informationCNA-Series - Large Industrial Heaters Tankless Water Heating Solutions
36-144 kw (122,800-491,300 BTUs) Certified Lead-Free Design New & Improved Pressure Drop Advantage Variable Temp Heat Exchanger NEMA 4 enclosure standard Independent Safeties ETL and cetl certified to
More informationSynergy3 Owner s Manual. Owner s Manual. Geothermal Heating Cooling Hot Water
Owner s Manual Geothermal Heating Cooling Hot Water 13 Contents System Benefits 2 How GeoExchange Systems Work 3 GeoExchange System Types 4 WaterFurnace Quality Commitment 5 Warranty 5 Operating Procedures
More informationKeltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions
36-144 kw (122,800-491,300 BTUs) Temperature overshoot purge system Certified Lead-Free Design NEMA 4 enclosure standard ASME and NB Certified options available New & Improved Pressure Drop Advantage Dual
More information50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS
50M56-743 Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD
More informationHYDROPONICS AND GREEN HOUSE CONTROLLER MODEL HGC-003 OWNER'S MANUAL FAN MAX TEMPERATURE LAMP DURATION FAN MAX HUMIDITY PUMP INTERVAL DECREASE
HYDROPONICS AND GREEN HOUSE CONTROLLER MODEL HGC-003 OWNER'S MANUAL REMOTE FLOOD AM PM PHOTO F rh PPM TEMPERATURE HUMIDITY SELECT RUN LAMP START FAN MAX TEMPERATURE LAMP DURATION FAN MAX HUMIDITY PUMP
More informationIndex Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:
Systems Index Systems - Systems Systems...1 -.16 General information Description...1 System description...2 Overview...3 Ordering details Arc monitor with detectors...4 Current sensing unit...5 Technical
More informationMPT Electric Fire Pump Controller
Setup and Operating Instructions MPT Electric Fire Pump Controller This manual provides general information, installation, operation, maintenance, and system setup information for Metron MPT Electric Fire
More informationProducts :: Circuit Protection :: Thermal Circuit Breakers
Products :: Circuit Protection :: Thermal Circuit Breakers Thermal Circuit Breaker CTB-Series CTB-Series PDF elibrary The CTB-Series is a compact, single pole, rocker actuated family of thermal circuit
More informationSECTION AUTOMATIC TRANSFER SWITCHES
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 This section specifies the furnishing, complete installation, and connection of automatic transfer switches. 1.2 RELATED WORK A. Section 14 21 00, ELECTRIC
More informationDual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual
We manage heat MANUAL Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239
More informationRemote Relay Module (RRM)
Remote Relay Module (RRM) Instruction Manual WARNING THIS MANUAL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR INSTALLING, USING OR SERVICING THIS PRODUCT. Like
More informationDiscontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications
36-144 kw (122,800-491,300 BTUs) Temperature overshoot purge system Certified Lead-Free Design NEMA 4 enclosure standard ASME and NB Certified options available Pressure Drop Advantage Dual Flow Activation
More informationwhole house safety Pocket Guide to Whole House Safety Siemens Energy & Automation, Inc Old Milton Parkway Alpharetta, GA 30005
Pocket Guide to Whole House Safety whole house SAFETY whole house Siemens Energy & Automation, Inc. 3333 Old Milton Parkway Alpharetta, GA 30005 1-800-964-4114 info.sea@siemens.com www.sea.siemens.com/afci
More informationNXM2G Installation and Operating Manual
NXM2G-1001 MARCH 26, 2014 NXM2G Installation and Operating Manual (-1 UL version shown) 40VG This manual must be affixed on or adjacent to the boiler or kept with boiler operating manual or other information.
More informationOperator: Save these instructions for future use!
50V64-743 Integrated Furnace Control for Furnaces with Variable Fan Speed INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
More informationKIT IOM
8733 800-259 KIT IOM Replacement Kit: 641-176 641-187 641-225 641-244 1 Table of Contents THE UPM CONTROLLER...3 SPECIFICATIONS...4 KIT INCLUDES...5 INSTALLATION PROCEDURE...5 Remove Old Board...5 Mounting
More informationPANELBOARDS & BUILDING DISTRIBUTION
262416 PANELBOARDS & BUILDING DISTRIBUTION PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Distribution panelboards 2. Power panelboards B. Related Sections: 1.02 POLICY 1. CU Standard 260500, Basic
More informationOperator: Save these instructions for future use!
WHITE-RODGERS 50A55-286 Integrated Furnace Control INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR
More informationSioux E-Series. All-Electric Compact Industrial Steam Cleaners & Pressure Washers. Sioux E-Series All-Electric Steam Cleaners and Pressure Washers
Sioux E-Series All-Electric Steam Cleaners and Pressure Washers Sioux E-Series All-Electric Compact Industrial Steam Cleaners & Pressure Washers Model E3.5HS3000 3 Consider Benefits... these Sioux s E-Series
More informationASSESSING THE HIDDEN DANGERS IN YOUR INDUSTRIAL CONTROL PANELS
Schneider Electric NEC 409.2 January 15, 2008 ASSESSING THE HIDDEN DANGERS IN YOUR INDUSTRIAL CONTROL PANELS by Grant Van Hemert, P.E., application engineer, Water and Wastewater Competency Center, Schneider
More informationSERIES 35-63J APPLICATIONS FEATURES SPECIFICATIONS AGENCY CERTIFICATIONS
SERIES 35-63J INSTALLATION INSTRUCTIONS FOR REPLACING JOHNSON CONTROLS G77X AND OTHER MODELS WITH FENWAL SERIES 35-63J IP IGNITION CONTROL APPLICATIONS The Fenwal 35-63J series Intermittent Pilot Ignition
More informationNEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage
NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers Maximizing Critical Sample Protection and Storage Innovative Features and Rewarding Benefits Features Advantage Benefit Refrigeration
More informationPortable Air Conditioner. Instruction Manual
Portable Air Conditioner Instruction Manual YPL3-08C Please read the instructions completely before using this product This product is designed for household use only. FOR SERVICE : CALL TRANS GLOBAL SERVICE
More informationCAUTION WARNING. 50T Integrated Furnace Control INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS
50T35-743 Integrated Furnace Control INSTALLATION INSTRUCTIONS FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY
More informationSpark Electrodes/Flame Sensors
Spark Electrodes/Flame Sensors For Gas Ignition Systems July 2016 DESCRIPTION Fenwal electrodes and sensors are an integral part of the ignition system for gas-fired equipment and ensure reliable ignition,
More informationPortable C1N Series - Light Industrial Heaters Tankless Water Heating Solutions
Heavy duty industrial cart options simplify moving heater to various locations 18-25 kw (61,4000-85,300 BTUs) Low flow activation options at 0.25 and 0.50 GPM (1.0 and 1.9 LPM) Certified Lead-Free Design
More informationQuality. Trust. Value. Safety.
Cutler-Hammer Type CH Loadcenters Product Focus The World s Finest Line of Loadcenters Many Exclusive Features Ease of Installation Save Time and Money Quality. Trust. Value. Safety. Features, Benefits
More informationPocket Guide usa.siemens.com/afci
Whole House Safety Pocket Guide usa.siemens.com/afci Use electricity safely everywhere in your home. What causes arc faults? Arc faults can occur for many reasons and anywhere in a home s electrical system.
More informationSolicitation Requirements Matrix
Access Control Provide barrier for controlled egress and ingress Solicitation Requirements Matrix Requirements Key Design Features Comment Faregates Provide retractable or paddle (swing) type barriers
More informationelite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems
5/25/16 rev 6 elite Model ELN General Specification 550 W to 1.5 KW elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems 1.0 General General Specification This specification
More informationControl and power circuit fusing to meet N.E.C.
LARGE VOLUME ELECTRIC WATER HEATERS SEV & SEH MODELS Commercial Electric ADVANCED State s new propriety electronic water heater control, provides precise + or - 1ºF temperature control, that is ideal for
More informationBGH Series Hot Surface Ignition Control
Installation Instructions BGH Series Issue Date April 14, 2011 BGH Series Hot Surface Ignition Control Application The BASO Gas Products BGH Series Hot Surface Ignition (HSI) control is microprocessor
More informationPipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual
MANUAL Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual Model FPT 130 Single Point Freeze Protection Heat Trace Control Table of Contents SCFP-CO-F130 Overview... 3 Installation...
More informationOperator: Save these instructions for future use!
WHITE-RODGERS 50A55-474 & 50A55-571 Integrated Furnace Controls INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
More informationSingle Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual
We manage heat MANUAL Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239
More informationAXS Strikemaster Engineering Manual
AXS Strikemaster AXS Strikemaster Programming and Operation Manual Jan 2014 Page 1 of 23 Table of Contents Important Note... 3 Features and Benefits... 3 Ordering Details... 4 Dimensions... 5 Installation...
More informationNECA 169. Standard for Installing and Maintaining Arc-Fault Circuit Interrupters (AFCIs) and Ground-Fault Circuit Interrupters (GFCIs)
NECA 169 Standard for Installing and Maintaining Arc-Fault Circuit Interrupters (AFCIs) and Ground-Fault Circuit Interrupters (GFCIs) Industry Review Draft (Date TBD) National Electrical Installation Standards,
More information