COMPANY INTRODUCTION RIKEN KEIKI

Size: px
Start display at page:

Download "COMPANY INTRODUCTION RIKEN KEIKI"

Transcription

1 COMPANY INTRODUCTION

2 1-1 MAIN BUSINESS Based on 70 years of experienece & know how, hold reliable / advanced sensor technology Ship buildin ng & Maritime Biz. Form prompt & accurate global service network with agents who cover all over the world Heavy ind. & Plant com. Biz. Portable & Fixed Gas detecto or Petro chemical Biz. Gas detection market KOGAS & CITY ga as Biz. Procure product quality by various association s approval 2

3 1-1 MAIN BUSINESS Portable Ga as Detector Gas leakage Checker Flammable gas detector O2 gas detector CO gas detector H2S gas detector CO2 gas detector Toxic gas detector Multi gas detector Portable gas calorie meter Solvent gas calorie meter Fumigation gas analyzer Anesthesia gas analyzer Gas purity analyzer SF-6 gas analyzer Salinity analyzer Formaldehyde detector 3

4 1-1 MAIN BUSINESS Fixed type G as Detector High Temp Furnace gas Flammable gas detector O2 gas detector CO gas detector H2S gas detector CO2 gas detector Toxic gas detector Multi gas detector Single type indicator Multi-channel indicator Diffusion type detector Pump sampling gas detector Transmitter type indicator Solvent gas calorie meter Solvent gas detector Fixed gas detection system 4

5 1-2 MAIN PRODUCT Marine Fixed Gas Detection System For Pump Room For Water Ballast Tank Simple and Compact Design Integrated Sampling and Monitoring for W.B.T, P/R and Accommodation Area Combined Design Auto Purge Function for Removing Suction Condensate Unit Repeater 5

6 1-2 MAIN PRODUCT Marine Fixed Gas Detection System Touch Panel Switch LCD Screen Display Flexible System Configuration(Remote LCD) Communication With IAS by Modbus Touch Screen for control & monitoring Provide Trip Contact Saves Installation Space Auto Purge Function for Removing Suction Condensate 6

7 1-3 SALES REFERENCE < VESSEL TYPE > TANKER COT/Product Tanker/PC 619 ships VLCC 37 ships LNG LPG SPECIAL SHIPS 47 ships 27 ships FPSO / FSO 9 ships Dive Ship 2 ships Drill Ship 6 ships Container 5 ships SHI DSME HHI HSHI / HMD STX SungDong < SHIPYARD > SHIP YARD Shina SB/Sekwang etc Overseas shipyard TOTAL Q ty 170 ships 62 ships 192 ships 102 ships 127 ships 45 ships 30 ships 30 ships 758 ships Above Sales figures are based on updated result on End of Dec For more detailed information on our sales records, contact to our company. 7

8 1-4 INTERNATIONAL SERVICE NETWORK < ADDITIONAL SE ERVICE BRANCH > 8

9 2-2 SYSTEM CONFIGURATION ( For LN NGC) 10

10 2-2-1 SAMPLING PANEL -SYSTEM DAIGRA AM Location : CCR C.C.R 11

11 2-2-2 SAMPLING PANEL PICTURE PANEL OUTSIDE PANEL INSIDE ASSEMBLY 12

12 2-2-3 SAMPLING PANEL EXTERIOR 13

13 2-2-4 SAMPLING PANEL External Fittings Connections (1) 14

14 2-2-4 SAMPLING PANEL External Fittings Connections (2) 15

15 2-2-4 SAMPLING PANEL External Fittings Connections (3) 16

16 2-3-1 DETECTION/CONTROL PANEL SYS TEM DIAGRAM Location : CCR C.C.R 17

17 2-3-2 DETECTION/CONTROL PANEL PICT TURE PANEL OUTSIDE PANEL INSIDE ASSEMBLY 18

18 2-3-3 GAS DETECTION/CONTROL PANEL EXTERIOR 19

19 2-3-4 TOUCH SCREEN For Monitoring & Control Installed on Front Door of Gas Detection/Control Panel 20

20 2-4 REPEATER ALARM UNIT - Total 2EA of Repeater Alarm unit provided. -1EA: installed in W/H (Fire Control Room) -1EA: installed in W/H (Wheel House) - From Sampling Panel & Detection/ /Control Panel : common alarm contact : Providedd 21

21 2-5 DETECTOR SPECIFICATION 22

22 2-5-1 Installation method per detector type 1. Normal type (Ceiling type) 23

23 2-5-2 Installation method per detector type 2. Duct mounting type (Flange type) 24

24 3 SYSTEM OPERATION SAMPLING PANEL DETECTION/CONTROL PANEL 2EA of REPEATER Communication to IAS RS 485 Serial Link Duplex LOCAL GAS DETECTOR 26

25 3 SYSTEM OPERATION It s Not the same with IAS Maker. We made it for only FAT purpose. Communication from Gas Detection/Control Panel to PC to be checked. 27

26 3 SYSTEM OPERATION < ALARM CHECK > (1) Gas Detector Check : Gas Concentration - Alarm Lamp (2) Touch Screen Check : Gas Concentration - Alarm Condition (Lamp / Buzzer) (3) Repeater Unit Check : Alarm Condition (Lamp / Buzzer) (4) IAS Check : Gas Concentration Alarm Condition (Lamp) 28

27 3 SYSTEM OPERATION TOUCH SCREEN CHECK POINT 29

28 31

GENERAL COMPANY & PRODUCT PRESENTATION

GENERAL COMPANY & PRODUCT PRESENTATION GENERAL COMPANY & PRODUCT PRESENTATION API MARINE Acoustic Precise Instruments Development, design & production of advanced tank sensors and automation systems for marine applications ABOUT API MARINE

More information

API Marine. Sensors Presentation. Mission critical applications in harsh environment. - API - Acoustic Precise Instruments -

API Marine. Sensors Presentation. Mission critical applications in harsh environment. - API - Acoustic Precise Instruments - API Marine Sensors Presentation Mission critical applications in harsh environment - API - Acoustic Precise Instruments - API Marine API Marine - Acoustic Precise Instruments Development, design and production

More information

SENSOR PRESENTATION MISSION CRITICAL APPLICATIONS IN HARSH ENVIRONMENT

SENSOR PRESENTATION MISSION CRITICAL APPLICATIONS IN HARSH ENVIRONMENT SENSOR PRESENTATION MISSION CRITICAL APPLICATIONS IN HARSH ENVIRONMENT API MARINE Acoustic Precise Instruments Development, design & production of advanced tank sensors and automation systems for marine

More information

API MARINE BMS4 REMOTE SOUNDING SYSTEM FOR BALLAST AND SERVICE TANKS

API MARINE BMS4 REMOTE SOUNDING SYSTEM FOR BALLAST AND SERVICE TANKS API MARINE BMS4 REMOTE SOUNDING SYSTEM FOR BALLAST AND SERVICE TANKS BMS4 TM TYPICAL CONFIGURATION BMS4 TM TYPICAL CONFIGURATION BMS4 TM SYSTEM (24 TANKS) Air regulator Terminal block Drain/Air Filter

More information

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display. Sheet No. 1 of 4 monitor/analyzer with alarm and Graphical Display. Sheet No. 2 of 4 It specially designed to analyze any gas of your choice, its automatic operation, accurate measurement and crystal clear

More information

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector Gas Detection RAE Systems by Honeywell Battery-Powered Wireless Gas Detector Battery-Powered Wireless Gas Detector The RAE Systems by Honeywell gas detection monitor is a key building block of the intelligent

More information

M2000 Engine Controller

M2000 Engine Controller M2000 Engine Controller Integrated control and protection of diesel and gas engines for all purposes Especially suited for auxiliary generator sets 1 IN OPERATION 1 2 STARTFAIL 2 3 OVERSPEED RPM FAIL 3

More information

incontrol Systems Inc. Flame and Gas Detection

incontrol Systems Inc. Flame and Gas Detection incontrol Systems Inc. Flame and Gas Detection Our flame and gas detectors are globally certified to the latest product approval standards Wherever toxic or combustible gases are part of an industrial

More information

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700 We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP 0584389 LEL. METERS Open-path Gas Detection Concepts 40-meter path 7m wide cloud

More information

Advanced tank technology

Advanced tank technology Advanced tank technology Sensors and Automation systems 2 API MARINE / ADVANCED TANK TECHNOLOGY Contents Introduction.... 5 Integrated Automation System Solution for Tankers... 8 Integrated Automation

More information

SMART Gas Detector/Transmitter(4~20mA) with built-in LCD & explosion proof DA-500

SMART Gas Detector/Transmitter(4~20mA) with built-in LCD & explosion proof DA-500 SMART Gas Detector/Transmitter(4~20mA) with built-in LCD & explosion proof DA-500 C-910C, Bupyeong Woolim Lion s Valley, #425, Cheongcheon-Dong, Bupyeong-Gu, Incheon, Korea TEL: +82-32-623-7507 FAX: +82-32-623-7510

More information

Automations Controls Experts

Automations Controls Experts ACE Instrumentation Automations Controls Experts ABOUT US ACE Instrumentation is renowned as one of the best marine automation company in Singapore. Our offices are located conveniently near shipyards

More information

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508 Open-Path Gas Detection System SAFEYE XENON 700 Hydrocarbons and ethylene detection Heated optics 10-year Warranty for the Xenon flash bulb SIL 2 according to IEC 61508 Certifications The Fixed Gas Detection

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Wed : www.saenchotesei.com WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 920 - Wall, 19 Rack or Panel Mounting Units - 110/230V 50/60Hz AC operation - 250 Addressable

More information

VASTHI ENGINEERS. Vasthi Explosive Meter Sheet No. 1 of 5. Vasthi Monitors for Combustible Gas.

VASTHI ENGINEERS. Vasthi Explosive Meter Sheet No. 1 of 5. Vasthi Monitors for Combustible Gas. Vasthi Explosive Meter Sheet No. 1 of 5 000000000000000000000 Vasthi Monitors for Combustible Gas. Vasthi Explosive Meter Sheet No. 2 of 5 Description : Vasthi (Model VS-70 E) HAND HELD PORTABLE COMBUSTIBLE

More information

SP-220. Features. Combustible handheld gas leakage detector

SP-220. Features. Combustible handheld gas leakage detector SP-220 Combustible handheld gas leakage detector The SP-220 gas leakage detector is a simple to operate unit with high sensitivity to a variety of gases. The SC version (SP-220SC) is able to detect super-toxic,

More information

Warranty Registration

Warranty Registration WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free from defects in workmanship and materials for a period

More information

The new generation of Multi-Gas measurement. Dipl.- Ing (FH) Andreas Hester, SIGAS Corp. Environment protection Personal safety Process control

The new generation of Multi-Gas measurement. Dipl.- Ing (FH) Andreas Hester, SIGAS Corp. Environment protection Personal safety Process control The new generation of Multi-Gas measurement Dipl.- Ing (FH) Andreas Hester, SIGAS Corp. Environment protection Personal safety Process control Today our environment is more and more contaminated by critical

More information

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T P R O D U C T D ATA S H E E T www.internationalgasdetectors.com Transmitters Control Systems OLIVER Sensors IGD Accessories TOCSIN 640 Pre-Configured Gas Detection System, CO2, O2 or N2O With all the features

More information

Rosemount Analytical Solutions. Emerson Offshore Technology Day March 26th 2015 by Rune Damgaard, Account Manager - Measure & Analyze

Rosemount Analytical Solutions. Emerson Offshore Technology Day March 26th 2015 by Rune Damgaard, Account Manager - Measure & Analyze Rosemount Analytical Solutions Emerson Offshore Technology Day March 26th 2015 by Rune Damgaard, Account Manager - Measure & Analyze Innovation applied to Offshore Applications Well head analysis Process

More information

Technical Manual. Electropneumatic Level Measuring System TYPE TN3801

Technical Manual. Electropneumatic Level Measuring System TYPE TN3801 TYPE TN3801 Technical Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Technical Manual TYPE TN3801 1 st Edition Released

More information

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T TOCSIN 640 Fast, Effective Gas Detection System Controller TOCSIN 640 is a multi-channel detector controller. Easy to install set up and operate with powerful interface features. Two Case Styles Are Available

More information

Fire protection solutions for ships and offshore facilities

Fire protection solutions for ships and offshore facilities Experts in fire protection Fire protection solutions for ships and offshore facilities BRANCH SOLUTION MARINE OVERVIEW Top level of safety on board Minimax has been one of the leading fire protection brands

More information

Recalibrate the way you look at gas detection

Recalibrate the way you look at gas detection Catalogue Gas detection solution Recalibrate the way you look at gas detection Next generation gas detection for industrial refrigeration The next generation of Danfoss gas detectors are based on a digital

More information

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual MODEL: SP12C7 (Portable 4 gas detector) Operating Manual Guarantee and Repair Senko Co., Ltd. guarantees the products of SP series for 24 months from the shipping date and repairs or replaces the defected

More information

TQ4400 TANKSCAN GAS SAMPLING SYSTEM OPERATING MANUAL

TQ4400 TANKSCAN GAS SAMPLING SYSTEM OPERATING MANUAL TQ4400 TANKSCAN GAS SAMPLING SYSTEM OPERATING MANUAL TQ Environmental Plc July 2009 This manual must not be copied or reproduced in part without the express written permission of TQ Environmental PLC.

More information

Advanced Tank Technology

Advanced Tank Technology Advanced Tank Technology Sensors and Automation Systems API Marine Advanced Tank Technology 02 Introduction... 5 Systems Integrated Automation System Solution for Tankers...................... 10 Integrated

More information

KAE Gas Alarm Operation Manual

KAE Gas Alarm Operation Manual KAE Gas Alarm Operation Manual Henan Hanwei Electronics Co.,Ltd ISO9001-2008 Precautions: To avoid personal safety injury, Instrument damage and potential dangerous accident; do not use gas detector before

More information

Electrostatic Hazard Control in Process Industry using Multi Channel Earth Monitor

Electrostatic Hazard Control in Process Industry using Multi Channel Earth Monitor Electrostatic Hazard Control in Process Industry using Multi Channel Earth Monitor www.static-control.in 1 Basic of Static Electricity The Generation of Static Electricity and build of its charge is present

More information

Dräger X-am 7000 Multi-Gas Detection

Dräger X-am 7000 Multi-Gas Detection Dräger X-am 7000 Multi-Gas Detection Dräger X-am 7000 is the solution for the simultaneous and continuous measurement of up to five gases. It is the ideal companion in a variety of applications where the

More information

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs Murco Core Product Guide Gas Leak Detection Solutions for all your building needs Refrigerant Gases Toxic Gases Combustible Gases VOC s Legislation: F Gas Regulation, EH40 Standards: EN378 Lloyds Approval

More information

Sensors and Automation systems Product Catalogue ATEX

Sensors and Automation systems Product Catalogue ATEX Sensors and Automation systems Product Catalogue ATEX Contents Vessel s Automation Systems TSS/Control - Integrated Automation System (IAS)... 4 TSS/Cargo - Cargo Control System for Tankers... 6 TSS/Alarm

More information

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T TOCSIN i700 SERIES Addressable & Analogue Gas Detection System Addressable technology from International Gas Detectors. Typical System is 40% Faster to Install with Fewer Connections Improved Reliability

More information

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2 Features Integrated (built-in NO2 sensor / detector (Electro chemical sensor type Measuring ranges 0-10 ppm, 0-20 ppm or 0-30 ppm LCD display to show actual in ppm Status LED indication Normal operation

More information

Honeywellmarine.com. Honeywell Proprietary

Honeywellmarine.com. Honeywell Proprietary Systems Overview Cargo Level Gauging System for tankers and FPSO Integrated system measuring level, temperature, inert gas pressure, etc, for ballast and cargo tanks Inclinometers (Trim and list) Provides

More information

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T PGF- Effective Gas Safety Proving and Gas Detection Controller Gas Pressure Proving For use with Natural Gas LPG - or Laboratory gas supplies, both high and low pressure ensuring system integrity prior

More information

DELIVER AS PROMISED A COMMITMENT TO CALIBRATION SERVICES ALL BRANDS & MAKERS PRESSURE / TEMPERATURE GAUGES & CALIBRATORS ULLAGE TAPES

DELIVER AS PROMISED A COMMITMENT TO CALIBRATION SERVICES ALL BRANDS & MAKERS PRESSURE / TEMPERATURE GAUGES & CALIBRATORS ULLAGE TAPES A COMMITMENT TO DELIVER AS PROMISED AMS - Atlas Marine Services, renowned in the marine industry for our impeccable service and capabilities. We were established to serve the ever evolving marine industry

More information

Fixed Fire Extinguishing Equipment and Systems

Fixed Fire Extinguishing Equipment and Systems Fixed Fire Extinguishing Equipment and Systems Sea Term 2016 Massachusetts Maritime Academy January 2016 DESIGN AND INSTALLATION OF FTXED SYSTEMS Fire extinguishing systems are designed and installed

More information

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T Keyless RFID Control PGF- Effective Gas Safety Proving and Gas Detection Controller RFID Gas Proving, Ventilation Control & Gas Detection, off one panel Our range of gas proving systems can be used for:

More information

Complete tank expertise. Marine tank management solutions for all ship types

Complete tank expertise. Marine tank management solutions for all ship types Complete tank expertise Marine tank management solutions for all ship types understanding of the conditions of the marine market. You ll find we re unique in our in-depth understanding of the details of

More information

The SMART Choice of Control & Automation. always on top of the situation

The SMART Choice of Control & Automation. always on top of the situation The SMART Choice of Control & Automation II always on top of the situation We proudly present the SMART Solution SMART Chief II is the newest generation of Integrated Automation Systems covering all functions

More information

Searchpoint Optima Plus

Searchpoint Optima Plus Searchpoint Optima Plus Advanced infrared point gas detector Searchpoint Optima Plus Why Infrared? Failsafe operation Fast speed of response Reduced routine maintenance Immune to catalytic poisons Long

More information

Marine Solutions. Honeywell s Solution for LNG Vessels

Marine Solutions. Honeywell s Solution for LNG Vessels Marine Solutions Honeywell s Solution for LNG Vessels Integrated automation systems for LNG vessels. Honeywell is the leading supplier of Integrated Automation Systems (IAS) for LNG carriers and newer

More information

GAS DETECTION International Gas Detectors CH4 NO

GAS DETECTION International Gas Detectors CH4 NO GAS DETECTION HSCO SOCO GAS DETECTORS FOR INDUSTRIAL ENVIRONMENTS TOCSIN 150 SERIES ADDRESSABLE GAS SAMPLERS Quality Assured HSCO SOCO In many applications in industry requiring gas detection it is often

More information

Document TM777030, rev. B. Initial release: 22 January 2008 Current release: 16 February 2010

Document TM777030, rev. B. Initial release: 22 January 2008 Current release: 16 February 2010 Peckman Industrial Park, 218 Little Falls Road, Cedar Grove, NJ 07009 Tel. 973-239-8398 Fax 973-239-7614 Email: spectrex@spectrex-inc.com HART Communication With the SharpEye Flame Detector Document TM777030,

More information

PRODUCT CATALOGUE. Gas & Air Quality Detectors Controllers Transmitters

PRODUCT CATALOGUE. Gas & Air Quality Detectors Controllers Transmitters PRODUCT CATALOGUE Gas & Air Quality Detectors Controllers Transmitters Engineered gas and environmental monitoring solutions for industry. Austech is a full lifecycle solution provider of gas, flame and

More information

OX100/OX102. Limiting-current type Oxygen Analyzer. Bulletin 11M10A01-03E

OX100/OX102. Limiting-current type Oxygen Analyzer. Bulletin 11M10A01-03E / Oxygen Analyzer Bulletin MA-3E A Compact Environmental Oxygen Anal yzer with the usual Yokogawa reliability MODEL MODEL Alarm Calibration keys holder: 7 mm (* ) dia. or G3/8 Plastic sensor holder (Specify

More information

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments VG07-018 Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments Mickey B. Frish, Richard T. Wainner, Matt C. Laderer Physical Sciences Inc. Andover, MA

More information

Applied Techno Systems

Applied Techno Systems +91-8048413395 Applied Techno Systems https://www.appliedtechnosystem.com/ We are industry leading Manufacturer and Supplier firm delivering state of art Gas Monitoring and Analyzing System. We aim to

More information

(h) Pesticide Application.

(h) Pesticide Application. Fire Code Cannabis Amendment Section 13.20.066 is added to the Marysville Municipal Code to read in its entirety as follows: 13.20.066 Cannabis Growing, Processing, or Extraction Facilities (a) Application.

More information

MODEL: SP2nd (Portable Single Gas Detector) Operating Manual

MODEL: SP2nd (Portable Single Gas Detector) Operating Manual MODEL: SP2nd (Portable Single Gas Detector) Operating Manual Edaphic Scientific Pty Ltd www.edaphic.com.au info@edaphic.com.au Guarantee and Repair Senko Co., Ltd. guarantees the products of SP series

More information

APP 721 MODBUS Mapping

APP 721 MODBUS Mapping SUMMARY This document is intended to be a reference for communicating with the Flygt APP721 controller using MODBUS RTU communication. Communication settings to the unit are as follows: MODBUS RTU, 8 data

More information

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2 PluraSens CH 4 C 2 H 2 C 3 H 8 CO CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2 VOC E2600 Family Gas Detectors E2610 Series Compact wall-mount housing providing optimal airflow Integrated sensor with long

More information

Sieger fixed gas detection. Fixed protection from hazardous gas

Sieger fixed gas detection. Fixed protection from hazardous gas Sieger fixed gas detection Fixed protection from hazardous gas Honeywell Analytics Honeywell Analytics is the world-leading specialist in gas detection and sensing technology, manufacturing an acclaimed

More information

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head 4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head NET DRAFT version 2.1-2008 Pag. 1 4-20mA Cyber - DRAFT version 2.1-2008 Pag.

More information

T.ex Single Gas Detector VISA

T.ex Single Gas Detector VISA T.ex Single Gas Detector The T.ex is newest instrument in the Promat portfolio. The instrument is currently available in Oxygen, Hydrogen Sulphide and Carbon Monoxide versions. A Bump Test Station is available

More information

Sieger Apex. Flexibility that meets your requirements

Sieger Apex. Flexibility that meets your requirements Sieger Apex Flexibility that meets your requirements Sieger Apex Easy to Install Sensor can be remotely mounted up to 100m from the transmitter On board relays allow for local audible/ visual alarms Strong

More information

YOUR PARTNER IN FIRE & GAS DETECTION

YOUR PARTNER IN FIRE & GAS DETECTION YOUR PARTNER IN FIRE & GAS DETECTION OGGIONI s.a.s. Via Lavoratori Autobianchi, 1 - P.T.B. Edif.13/O - 20832 Desio (MB) Italy Tel.+39 0362 629135 Fax. +39 0362 622531 www.oggionisas.com - info@oggionisas.com

More information

UNITY CEILING RECESSED MOUNT CM1900 CM1901 CM1906 CM1912

UNITY CEILING RECESSED MOUNT CM1900 CM1901 CM1906 CM1912 UNITY CEILING RECESSED MOUNT CM1900 CM1901 CM1906 CM1912 Drawing: 762000XX Rev: A Sheet: 1 of 8 Eng: CLD Date Drawn: 04/21/17 TYPICAL GRID CEILING RECESSED FIXTURE MOUNTING SUPPORT WIRE HOUSING SLOT #8

More information

Hygrometer / Air Quality Meter

Hygrometer / Air Quality Meter Hygrometer / Air Quality Meter PCE-313 A Professional Thermohygrometer with SD Card Memory / Data Logger measures temperature and humidity by internal sensor and temperature by K type thermocouple calculates

More information

DASPOS A/S Gammel Klausdalsbrovej Herlev Denmark Tel.: website: DASPOS USA, Inc NE 116th Street, PMB

DASPOS A/S Gammel Klausdalsbrovej Herlev Denmark Tel.: website:   DASPOS USA, Inc NE 116th Street, PMB LAS-10 - Leakage Alarm System Atmospheric oil mist and hydrocarbon detection Early warning system Your challenges Each year, there are several hundred fires recorded aboard merchant ships; 63% occur in

More information

Application Bulletin. LNG / LPG Facilities FLAME AND GAS DETECTION FOR LNG FACILITIES

Application Bulletin. LNG / LPG Facilities FLAME AND GAS DETECTION FOR LNG FACILITIES FLAME AND GAS DETECTION FOR LNG FACILITIES Liquefied natural gas (LNG) is a generic name for liquefied hydrocarbon gas composed primarily of methane. When natural gas is cooled to approximately -260 F,

More information

Accuracy by Design Products for the HVAC Professional

Accuracy by Design Products for the HVAC Professional Accuracy by Design Products for the HVAC Professional Greystone Energy Systems Inc., is one of North America s largest ISO registered manufacturers of HVAC sensors and transducers for Building Automation

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Control Systems Transmitters Sensors Accessories Wall, 19 Rack or Panel Mounting Units 110/230V 50/60Hz AC operation 250 Addressable devices as: Relays, 4-20 Inputs or Gas Detectors

More information

KAB Gas Alarm Operation Manual

KAB Gas Alarm Operation Manual KAB Gas Alarm Operation Manual Henan Hanwei Electronics Co.,Ltd ISO9001-2008 Precautions: To avoid personal safety injury, Instrument damage and potential dangerous accident; do not use gas detector before

More information

Report from the Division for Investigation of Maritime Accidents

Report from the Division for Investigation of Maritime Accidents Report from the Division for Investigation of Maritime Accidents Engine room fire MAERSK MASTER Factual information MAERSK MASTER, OXEI2, IMO No. 8409379 is an anchor handling supply tug of 3949 BT. The

More information

TKF Co.,Ltd.

TKF Co.,Ltd. Pre-Qualification (2014) T K F TKF Co.,Ltd. www.saeflange.co.kr Contents 1. President Message 2. History of Company 3. 2014 Quality Policy 4. Quality management system 5. Certificates 6. Organization 7.

More information

FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS.

FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS. SERVOTOUGH FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS Flexible Can be used in hazard rated locations including Zone

More information

Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE:

Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE: The RO120 is a precision transmitter that provides quick and accurate humidity, barometric pressure, temperature, absolute pressure and dew point measurements in a wide range of applications. It has a

More information

CH4 SO2NO2. C O2 mount options. The controller has two SPCO relays as standard with three 4-20mA outputs and an RS485 Modbus UK Design And Manufacture

CH4 SO2NO2. C O2 mount options. The controller has two SPCO relays as standard with three 4-20mA outputs and an RS485 Modbus UK Design And Manufacture el: +44 (0)161 483 141 Fax: +44 (0) 161 484 34 SYS HS S is a multi-channel detector controller in an easily installed and implemented small format package. he system can be used with any of the ocsin Addressable

More information

Dew-Point Transmitters and Instruments

Dew-Point Transmitters and Instruments Dew-Point Transmitters and Instruments Reliable moisture measurement for critical process control Moisture Measurement and Analysis Michell Instruments sensors provide accurate and reliable moisture measurement

More information

Intelligent solutions for tank monitoring

Intelligent solutions for tank monitoring Intelligent solutions for tank monitoring CARGOMASTER Product overview Tank monitoring systems Company facts The Marine Centre within the KROHNE Group, taking care of all business related to ship systems

More information

The benefits of modern Integrated Control and Safety Systems architectures for FPSO facilities.

The benefits of modern Integrated Control and Safety Systems architectures for FPSO facilities. The benefits of modern Integrated Control and Safety Systems architectures for FPSO facilities. P. Troianiello - Fores Engineering Rosetti Marino Group A. Gariboldi - Siemens Industry Sector IA/DT Topics

More information

Fire protection solutions for ships and offshore facilities BRANCH SOLUTION

Fire protection solutions for ships and offshore facilities BRANCH SOLUTION Fire protection solutions for ships and offshore facilities BRANCH SOLUTION SAFETYCompetent Ships and offshore facilities such as oil platforms require an above-average level of safety due to the special

More information

Product Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S

Product Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S D10 is a type-approved measuring device which combines the advantages of the measuring principles transmittance and scattered light forward. Therefore, it is ideal for measurement of very low to high dust

More information

Installation and Wiring 1.

Installation and Wiring 1. Installation and Wiring 1. Please read the Security Notifications in detail firstly. 2. The gas detector might install on wall or steel plate, please refer following drawing to make marking then drill

More information

GAS ANALYSIS / DETECTION Gas Detector

GAS ANALYSIS / DETECTION Gas Detector Eikon - Single gas recyclable personal monitor GAS ANALYSIS / DETECTION Tough and rugged Eikon is the durable single gas fixed life personal monitor that really lasts the course. Loud & Clear Alarms Easy

More information

MB05. RESPOND TO EMERGENCIES BASIC KNOWLEDGE OF EMERGENCY PROCEDURES, INCLUDING EMERGENCY SHUTDOWN

MB05. RESPOND TO EMERGENCIES BASIC KNOWLEDGE OF EMERGENCY PROCEDURES, INCLUDING EMERGENCY SHUTDOWN MB05. RESPOND TO EMERGENCIES BASIC KNOWLEDGE OF EMERGENCY PROCEDURES, INCLUDING EMERGENCY SHUTDOWN Content of the lecture 1. DRILLS AND EMERGENCY EXERCISES (general requirements) 2. Emergency procedures

More information

SOLUTIONS PROVIDER FOR THE SHIP AUTOMATION AND MARINE INSTRUMENTATION

SOLUTIONS PROVIDER FOR THE SHIP AUTOMATION AND MARINE INSTRUMENTATION Worldwide service from Rotterdam Marine Automation & Instrumentation Measurement & Control Systems Fire & Gas Detection Navigation Equipment Test & Calibration Equipment Sales Systems and Parts SOLUTIONS

More information

Remote Controls POOL SPA & FILTRATION SUPPLIES (PTY) LTD REMOTE SYSTEMS

Remote Controls POOL SPA & FILTRATION SUPPLIES (PTY) LTD REMOTE SYSTEMS ECR6-6 channel remote 6 Code hopping channels Each channel can be code hopping or be programmed with an 8-digit fixed code Unique serial number for each remote control Easy to use single key press operation

More information

Picture Report for Maersk Jabal

Picture Report for Maersk Jabal Picture Report for Maersk Jabal Vessel Name: Maersk Jabal Customer: Maersk line Ship Mgnt. Location: Keppel shipyard & Anchorage Date: 26 Mar 2016 to 06 April 2016 Jobs Description: To check and service

More information

PLATE HEAT EXCHANGERS FOR MARINE APPLICATIONS

PLATE HEAT EXCHANGERS FOR MARINE APPLICATIONS PLATE HEAT EXCHANGERS FOR MARINE APPLICATIONS www.tranter.com There are times when the reliability of your equipment is crucial! When conditions are tough, crew and equipment are really put to the test.

More information

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD SYSTEM CENTERS FRANCE Dräger Safety France S.A.S. 3c, Route de la Fédération 67025 Strasbourg Cedex Tel +33 388 40 76 76 Fax +33 388 40 76 67 P. R. CHINA Beijing Fortune Draeger Safety Equipment Co., Ltd.

More information

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM 2 Line, 16 Characters/row LCD Display Temperature Input Range -50 C to +500 C -58 F to + 932 F Enclosure NEMA Type 4X Current Rating 30A max (resistive load only) Ambient Temperature -40 C to + 40 C -40

More information

HEALTHCARE SAFETY INSPECTION

HEALTHCARE SAFETY INSPECTION Facility/Location: HEALTHCARE SAFETY INSPECTION Inspected By: Date: OPERATING ROOM YES NO HAZARD CORRECTIVE ACTION Initial & Date 1. Has a designated safety person been appointed to oversee OR safety issues?

More information

Dust Alert 75. *shown with optional external keypad and display

Dust Alert 75. *shown with optional external keypad and display Dust Alert 75 Designed to differentiate between gross failure and dust leakage from faulty/failing filter systems including bag filters Automatic internal zero and reference self-checks for regulatory

More information

Heating Systems OWNER S MANUAL. Hea ng Center

Heating Systems OWNER S MANUAL. Hea ng Center Heating Systems OWNER S MANUAL Hea ng Center CE70069 Clean Energy Heating Systems, LLC 540 Maple Street, Honey Brook, PA 19344 www.cleanenergyheatingsystems.com (888) 519-2347 10/21/13 Part # 70005 TABLE

More information

(SA3002CHE) CHARCOAL Chrome Knobs with T Bar Styled Handles (SA3002MDE) MIDNIGHT Satin Knobs with T Bar Styled Handles

(SA3002CHE) CHARCOAL Chrome Knobs with T Bar Styled Handles (SA3002MDE) MIDNIGHT Satin Knobs with T Bar Styled Handles 003018 (SA3002CHE) CHARCOAL Chrome Knobs with T Bar Styled Handles 003022 (SA3002MDE) MIDNIGHT Satin Knobs with T Bar Styled Handles Specifications MK3 Caprice Grill and Oven Burner Hotplate Burners Weight

More information

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels MS3602CH 2 Channel Motion Sensor For Outdoor Use Wall & Ceiling Mounted Quick & Easy Installation 2 Channels Channel 2 Distance Wiring Diagram 220-240V ~ 50Hz 14A Max. (cosø=1) 3000W for incandescent load

More information

Enterprise with dream, hope, and future

Enterprise with dream, hope, and future Enterprise with dream, hope, and future www.tmc-cable.com Company Overview Global leadership in the specialty industrial cable market ENTERPRISE WITH DREAM, HOPE, AND FUTURE TMC Co., Ltd has been pursuing

More information

Industrial Grade Gas Detection

Industrial Grade Gas Detection Industrial Grade Gas Detection DETECTING THE... Difference Catalog #CB 0912 detcon inc. an company www.detcon.com Houston Odessa Shanghai Dammam Del Carmen UK Company Profile ISO 9001: 2008 Certified 105-A

More information

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T P R O D U C T D ATA S H E E T www.internationalgasdetectors.com Transmitters Control Systems Sensors Accessories TOCSIN 90 Wall, 19 Rack or Panel Mounting Units 110/30V 50/60Hz AC operation 50 Addressable

More information

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex Part 2 Direct Reading Instrumentation Direct Reading Instruments Many different instruments Many different operating principles including: Electrochemical Photoionisation Flame ionisation Chemiluminescence

More information

Winnipeg Fire Department Fire Prevention Branch

Winnipeg Fire Department Fire Prevention Branch Winnipeg Fire Department Fire Prevention Branch Manitoba Fire Code Life-Safety Equipment Maintenance Requirements The Fire Prevention Branch of the Winnipeg Fire Department has prepared this document of

More information

CP01 Fixed gas detector

CP01 Fixed gas detector CP01 Fixed gas detector Operation manual Please read this manual carefully and thoroughly before using this product Ver:HWWM161229CG CP01 Fixed gas detector operation manual Table of contents 1. BRIEF

More information

Industrial Grade Gas Detection

Industrial Grade Gas Detection Industrial Grade Gas Detection DETECTING THE... Difference Catalog #CB 0112 detcon inc. an company www.detcon.com Houston Odessa Shanghai Dammam Del Carmen Europe Company Profile ISO 9001: 2008 Certified

More information

Zircomat Oxygen Analyzers

Zircomat Oxygen Analyzers Zircomat Oxygen Analyzers Finally Hassle Free Stack Gas Oxygen Measurement Many of the top fortune 500 companies have already discovered that installing a ZIRCOMAT Oxygen analyzer is the smart way to measure

More information

Industrial Grade Gas Detection Detecting The Difference

Industrial Grade Gas Detection Detecting The Difference detcon inc. Industrial Grade Gas Detection Detecting The Difference PO Box 8067 The Woodlands, TX 77387 888-367-4286 (toll free) 713-559-9200 281-292-2860 (fax) sales@detcon.com Catalog #CB-0409 www.detcon.com

More information

Safe Operation Manual. Honeywell IQ Force Gas Detector

Safe Operation Manual. Honeywell IQ Force Gas Detector Safe Operation Manual Honeywell IQ Force Gas Detector Honeywell Analytics 800-663-4164 403-248-9226 Fax 403-575-3708 03JUN2012 P/N 50105843-047 Version 01 http://www.honeywell.com HONEYWELL IQ Force PERSONAL

More information

MeshGuard and MeshGuard Gamma

MeshGuard and MeshGuard Gamma and RAE Systems by Honeywell Battery-Powered Wireless Gas Detector and Radiation Detector Battery-Powered Wireless Gas Detector Key Features Self-forming wireless network; units come online automatically

More information