1 Radon Reference Facility at Bowser-Morner, Inc. AMUG Meeting Las Vegas May 4, 2010 Phillip H. Jenkins, PhD, CHP

2 Radon Reference Facility What We Do Calibration of Rn and RDP measuring devices Spiking of Rn measuring devices Blind Performance Tests for clients maintaining certification (or licensing) with: NEHA/NRPP NRSB NJ, PA, ME, RI CNSC

3 Radon Reference Facility Product Testing Research Consulting Training What We Do

4 Calibration of Rn & RDP Devices Calibration, quality assurance testing, product development, etc. requires exposing devices to known and controlled atmospheres of radon and/or radon decay products. The design of the atmosphere, or radon chamber, may vary significantly depending on the intended use.

5 Radon Chamber Design More Complicated Than You Might Think Size of chamber? Recirculating or Pass-Through? Stagnant or air flow, and if so how much? Temperature and humidity control? Source of radon? How to monitor the radon concentration?

6 A Little Radon Chamber History 1980 When we were designing the radon chamber at Mound, we toured and took ideas from chambers at: EML, New York, NY EPA Montgomery, AL Bureau of Mines, Denver, CO University of Toronto

7 A Little Radon Chamber History 1980 Chamber designs varied greatly: EML was a large walk-in chamber with recirculating flow. EPA Montgomery was a single-pass design made from four plywood sheets to form a 8 x 4 x 4 foot box. BOM s chamber was held at high concentrations, where others were lower environmental levels. None had temperature and humidity control at that time.

8 A Little Radon Chamber History Source of Radon The chamber must have a source of radon as input. Chambers used several types of sources: Radium in solution, air bubbled through to collect radon (EML). Uranium Ore, Mill Tailings or Phosphate Slag Soil Gas Commercially available radon sources from Pylon; one-shot sources, flow-through sources.

9 A Little Radon Chamber History Mound design: 1980 Walk-in chamber, 9 x 9 x 8 ft, with antilock room. Recirculating flow through an external environmental chamber for temperature and humidity control. Radium in solution with bubbler (like EML).

10 A Little Radon Chamber History 1980 s Soon after Mound chamber was built: EML retrofitted its chamber for temperature and humidity control. EPA Montgomery built two large walk-in chambers with temperature and humidity control. Large chamber built at DOE s Grand Junction facility with temperature and humidity control. EPA Las Vegas built a large walk-in chamber with temperature and humidity control (ultimately had three chambers).

11 A Little Radon Chamber History 1986, DOE s need for the chamber at Mound was ending just as the need within the private sector was beginning. Mound chamber was used for about 3 years to support private efforts (manufacturers, laboratories) for calibration, product development, quality assurance testing. An incident ended the operation of the chamber at Mound in By that time there were private companies that were operating chambers.

12 A Little Radon Chamber History 1991, I left Mound and started designing and building a chamber at Bowser-Morner, Inc. I toured (again) the chambers at the two EPA facilities. I used ideas from EML, Mound and the two EPA facilities. Today, the only chambers (that I know of ) in the US government are the one at EPA Las Vegas and one at ORNL.

13 A Little Radon Chamber History Bowser-Morner chamber design: Large walk-in room, 12 x 12 x 9 ft (same as EPA Las Vegas) Recirculating flow Source, two flow-through Pylon Ra-226 sources External environmental chamber for temperature and humidity control (same as Mound) Designed to minimize the amount of radium to purchase and license, as well as the amount of radon that would be released to the environment

14 Bowser-Morner Radon Chamber

15 Chamber Layout (Similar to EPA/Las Vegas) 2.54 m 1.37 m 3.84 m (12 ft) Hgt = 2.71 m Vol = 9.45 m m (12 ft) Air Lock Height = 2.71 m (9 ft) Volume = 39 m 3

16 Bowser-Morner Radon Chamber

17 Air Lock Chamber Conditioned air is blown from the environmental chamber, through the radon chamber and back at a rate of 100 cfm. Air velocity in chamber is fpm. Rn Conditioning Chamber 8-ft 3 Environmental Chamber Radon is continuously pumped into return leg to environmental chamber. Two chambers form a closed loop.

18 Radon Sources 238 kbq mci 500 kbq mci

19 Radon Measurement System Three Eberline SACR-5 Photomultiplier Tubes/Scintillation Cells Tennelec Electronics and Counting System (to be replaced with more modern equipment)

20 Environmental Chamber

21 Chamber Interior

22 Chamber Interior

23 Intercomparisons EPA Las Vegas Lab Fills my scintillation cells from NIST traceable 226 Ra source. At Bowser-Morner I analyze the cells and report results to proficiency programs. At Bowser-Morner The same cells are used to take measurements from chamber and compare with continuous monitoring system.

24 Atomizer from article by Leong, Wang, Stukel & Hopke We used an atomizer of this design at Mound to generate an aerosol in the chamber air for radon decay product work. When EPA Las Vegas lab built their first chamber, they borrowed this idea from Mound. In the early 90s I borrowed the idea back from EPA Las Vegas lab to use at Bowser-Morner.

25 Atomizer

26 Aerosol Generator Atomizes salt solution. Aerosol stream passes through heated tube then across desiccant, then into chamber.

27 Condensation Particle Counter TSI Model 3022A

28 RDP Monitor Alpha Nuclear Used as a continuous gross alpha counter. Calibrated to RDP concentration upon each use through comparisons with grab RDP measurements.

29 Intercomparisons for RDPs EPA Las Vegas Lab Side-by-side measurements with EPA personnel. At Bowser-Morner I analyze my results and report to proficiency programs. At Bowser-Morner Grab sampling during every test. Continuous monitor used for gross-alpha only. A least squares procedure used to fit the data to the grab measurements (calibrating the monitor for each use).

30 Personal Alpha Dosimeter (PAD)

31 PAD Charging Unit at Mine

32 Personal Alpha Dosimeter (PAD)

33 Personal Alpha Dosimeter (PAD)

34 Personal Alpha Dosimeter (PAD)

35 PAD Detector Head

36 Personal Alpha Dosimeter (PAD)

37 Personal Alpha Dosimeter (PAD) Stall pressure is measured before and after each exposure.

38 Personal Alpha Dosimeter (PAD)

39 From CNSC Regulatory Standard S-106 Range of Measurement Overall Accuracy (95% Confidence) 0.05 WLM (177 µj h m -3 ) to < 0.10 WLM (354 µj h m -3 ) +100% / -50% 0.10 WLM (354 µj h m -3 ) +50% / -33% Range of Measurement Overall Accuracy (95% Confidence) 0.05 WL (1.03 µj m -3 ) to < 0.10 WL (2.08 µj m -3 ) +100% / -50% 0.10 WL (2.08 µj m -3 ) +50% / -33%

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points Topic 4 - Audio 46 Key Points : Measures taken to increase confidence in results. Quality Assurance: Program that assures that measures are being done and in a timely manner. Precision: How close measurements

More information

National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate

National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate Environmental and Food Measurements Lab & Individual monitoring lab Yemen Republic Population : 22 million

More information

THE EFFECT OF VENTILATION AND FILTRATION ON RADON DECAY PRODUCT MEASUREMENTS

THE EFFECT OF VENTILATION AND FILTRATION ON RADON DECAY PRODUCT MEASUREMENTS THE EFFECT OF VENTILATION AND FILTRATION ON RADON DECAY PRODUCT MEASUREMENTS Bill Brodhead WPB Enterprises, Inc., 2844 Slifer Valley Rd., Riegelsville, PA USA wmbrodhead@hotmail.com www.wpb-radon.com ABSTRACT

More information

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date: LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: ALPHA TRACK Method Number: ELAP method number 7035 SOP Number: Revision Number: SOP Date: Personnel / Data Records observed: Page 1 of 6 RADON IN AIR

More information

CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting

CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting Method Number: ELAP method number 7036 SOP Number: Revision Number:

More information

Paul Kotrappa, Ph.D. and Carolyn Allen. Rad Elec Inc., 5714-C Industry Lane, Frederick, MD USA

Paul Kotrappa, Ph.D. and Carolyn Allen. Rad Elec Inc., 5714-C Industry Lane, Frederick, MD USA 177 REVIEW OF QA\QC ASPECTS OF ELECTRET ION CHAMBERS- MANUFACTURING PRACTICES AND PERFORMANCE IN WORLDWIDE INTER-COMPARISON EXERCISES IN THE PAST EIGHT YEARS Paul Kotrappa, Ph.D. and Carolyn Allen Rad

More information

Measurement Devices. Topic 5 - Audio 56

Measurement Devices. Topic 5 - Audio 56 Topic 5 - Audio 56 Other Classifications Passive devices: Air diffuses in No power required for sampling Active devices: Requires power Pumps air through filter Key Points - Devices What lab sees: Different

More information

Policy Manual. April 21,2015. National Radon Proficiency Program 2015

Policy Manual. April 21,2015. National Radon Proficiency Program 2015 Policy Manual April 21,2015 National Radon Proficiency Program 2015 AARST - National Radon Proficiency Program (NRPP) ~ Page 1 TABLE OF CONTENTS I. General Application 4 II. Residential Measurement Provider

More information

The Regulatory Perspective on Radiation Protection in Canadian Uranium Mines

The Regulatory Perspective on Radiation Protection in Canadian Uranium Mines Canadian Nuclear Safety Commission Commission canadienne de sûreté nucléaire The Regulatory Perspective on Radiation Protection in Canadian Uranium Mines Presentation to URAM-2009 Vienna, Austria June

More information

Use of MCNPX for Alpha Spectrometry Simulations of a Continuous Air Monitor

Use of MCNPX for Alpha Spectrometry Simulations of a Continuous Air Monitor Page 1 DOE/NV/XXXXX--XX Use of MCNPX for Alpha Spectrometry Simulations of a Continuous Air Monitor Robert B. Hayes, Ph.D., CHP, PE Senior Scientist Remote Sensing Laboratory PO Box 98521, Mail Stop RSL-47

More information

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ELECTRET by Voltametry. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ELECTRET by Voltametry. Method Number: ELAP method number SOP Number: Revision Number: SOP Date: LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: ELECTRET by Voltametry Method Number: ELAP method number 7034 SOP Number: Revision Number: SOP Date: Personnel / Data Records observed: General LLD:

More information

RADON SCREENING SURVEY FOLLOW-UP WHITTIER WOODS CENTER Whittier Boulevard, Bethesda, Maryland 20817

RADON SCREENING SURVEY FOLLOW-UP WHITTIER WOODS CENTER Whittier Boulevard, Bethesda, Maryland 20817 RADON SCREENING SURVEY FOLLOW-UP WHITTIER WOODS CENTER 7100 Whittier Boulevard, Bethesda, Maryland 20817 EXECUTIVE SUMMARY Date of Test Report: 5/12/16 Round of Testing: Initial Follow-up Post Remediation

More information

AC, AT, LS Measurement Devices

AC, AT, LS Measurement Devices Group Designations for Measurement Devices The following is a list of devices approved by the NRSB. These devices were either approved by the EPA Radon Proficiency Program prior to its closure in 1998

More information

Radiation Monitoring Equipment

Radiation Monitoring Equipment Radiation Monitoring Equipment Sharon Paulka Regional Training Course RAF 3007-1 Namibia, 17-21 August 2009 International Atomic Energy Agency Types of Monitoring Both Occupational & Environmental Require

More information

Ohio Department of Health, Bureau of Environmental Health and Radiation Protection, Radon Licensing Program. School Radon Testing Checklist

Ohio Department of Health, Bureau of Environmental Health and Radiation Protection, Radon Licensing Program. School Radon Testing Checklist Ohio Department of Health, Bureau of Environmental Health and Radiation Protection, Radon Licensing Program School Radon Testing Checklist Purpose: This checklist has been prepared to provide school employees

More information

CURRENT STATE OF THE ART IN MEASURING ENVIRONMENTAL RADON. Abstract

CURRENT STATE OF THE ART IN MEASURING ENVIRONMENTAL RADON. Abstract CURRENT STATE OF THE ART IN MEASURING ENVIRONMENTAL RADON A.C. George and N. Bredhoff Radon Testing Corporation of America Elmsford, New York Abstract According to the US EPA, radon is the leading cause

More information

RADON SCREENING SURVEY FOLLOW-UP CONCORD CENTER Hidden Creek Rd, Bethesda, Maryland 20817

RADON SCREENING SURVEY FOLLOW-UP CONCORD CENTER Hidden Creek Rd, Bethesda, Maryland 20817 RADON SCREENING SURVEY FOLLOW-UP CONCORD CENTER 7210 Hidden Creek Rd, Bethesda, Maryland 20817 EXECUTIVE SUMMARY Date of Test Report: 3/31/16 Follow-Up Round of Testing: Initial Follow-up Post Remediation

More information

RADON SCREENING SURVEY FOLLOW-UP GREAT SENECA CREEK ELEMENTARY SCHOOL Dairymaid Drive, Germantown, Maryland 20874

RADON SCREENING SURVEY FOLLOW-UP GREAT SENECA CREEK ELEMENTARY SCHOOL Dairymaid Drive, Germantown, Maryland 20874 RADON SCREENING SURVEY FOLLOW-UP GREAT SENECA CREEK ELEMENTARY SCHOOL 13010 Dairymaid Drive, Germantown, Maryland 20874 EXECUTIVE SUMMARY Date of Test Report: 3/31/16 Follow-Up Round of Testing: Initial

More information

C-NRPP Quality Assurance Guidance for Radon Test Devices

C-NRPP Quality Assurance Guidance for Radon Test Devices C-NRPP Quality Assurance Guidance for Radon Test Devices Table of Contents: 1. Purpose 2. Definitions 3. Quality Assurance Plan 4. Calibration 5. Spikes/Performance Tests 6. Duplicates 7. Blanks 8. Cross-Checks

More information

Quality and Technology - Made in Germany -

Quality and Technology - Made in Germany - Quality and Technology - Made in Germany - TRACERLAB GmbH Aachener Str. 1354 50859, Koeln, Germany Tel.: +49 (0) 2234-942397 Fax.: +49 (0) 2234-942398 E-mail: asktracerlab@tracerlab.com Internet: www.tracerlab.com

More information

their original bags during the test period determine what background reading they might accumulate. The actual

their original bags during the test period determine what background reading they might accumulate. The actual AARST ANNUAL RADON CONFERENCE OCTOBER 4,5,6 1990 COMPARISON OF LONG TERM TESTING DEVICES INDOOR AND OUTDOOR Bill Brodhead WPB Enterprises, Inc. 2844 Slifer Valley Rd. Riegelsville, Pa., 18077 610-346-8004,

More information

A new passive integrating detector for measurement of individual radon exposure at working places.

A new passive integrating detector for measurement of individual radon exposure at working places. A new passive integrating detector for measurement of individual radon exposure at working places. G. Sciocchetti, G. Cotellessa, E. Soldano, M. Pagliari and A. Ceccatelli (*) ENEA-ION-IRP, Centro Ricerche

More information

Alpha Attenuation Due to Dust Loading. Amber E. Dailey Francis Marion University Savannah River Site

Alpha Attenuation Due to Dust Loading. Amber E. Dailey Francis Marion University Savannah River Site Alpha Attenuation Due to Dust Loading Amber E. Dailey Francis Marion University Savannah River Site Purpose The purpose of this experiment was to properly correct for the attenuation of the energy of alpha

More information

Woodlin Elementary School Date of Report March 14, 2018

Woodlin Elementary School Date of Report March 14, 2018 MCPS RADON TESTING - EXECUTIVE SUMMARY Site Name Woodlin Elementary School Date of Report March 14, 2018 Round of Testing Initial Follow-up Post Remediation 2 year testing 5 year testing HVAC Upgrade Window

More information

Presentation to NC Home Inspectors Licensure Board April 7, Opportunities and Partnerships

Presentation to NC Home Inspectors Licensure Board April 7, Opportunities and Partnerships Presentation to NC Home Inspectors Licensure Board April 7, 2017 Opportunities and Partnerships Radon Basics 2 Radon Basics Radon is the leading environmental cause of lung cancer Source of radon is the

More information

RADON PLAN. Eugene School District 4J Facilities Management 715 West Fourth Avenue Eugene, OR

RADON PLAN. Eugene School District 4J Facilities Management 715 West Fourth Avenue Eugene, OR RADON PLAN The 2015 Legislature passed House Bill (HB) 2931 so that if elevated radon levels in Oregon schools existed they would be known. House Bill 2931 later became Oregon Revised Statute (ORS) 332.166-167.

More information

Radon Measurement Survey Report. McKnight School Service Center 417 Fifth Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. McKnight School Service Center 417 Fifth Street Aurora, Illinois Prepared For: Radon Measurement Survey Report Site: 417 Fifth Street Aurora, Illinois 60505 Survey Dates: May 9, 2018 thru May 11, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois

More information

Radon Measurement Survey Report. Krug Elementary School 240 Melrose Avenue Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Krug Elementary School 240 Melrose Avenue Aurora, Illinois Prepared For: Radon Measurement Survey Report Site: 240 Melrose Avenue Aurora, Illinois 60505 Survey Dates: May 1, 2018 thru May 3, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois

More information

CHAPTER 240. RADON CERTIFICATION

CHAPTER 240. RADON CERTIFICATION CHAPTER 240. RADON CERTIFICATION Subchap. Sec. A. GENERAL PROVISIONS...240.1 B. CERTIFICATION...240.101 C. CERTIFICATION REVIEW PROCEDURES AND STANDARDS...240.201 D. OPERATION REQUIREMENTS...240.301 E.

More information

Radon and Thoron Measurements at Special Underground Circumstances

Radon and Thoron Measurements at Special Underground Circumstances Radon and Thoron Measurements at Special Underground Circumstances Tibor Kovács a*, Norbert Kávási b, Csaba Németh c, János Somlai a, Tamás Vigh d, Gábor Szeiler a, and Shinji Tokonami e, Hiroyuki Takahashi

More information

Bethel School District Radon Testing Plan

Bethel School District Radon Testing Plan The 2015 Oregon Legislature passed House Bill (HB) 2931 so that elevated radon levels in Oregon schools would be known. House Bill 2931 later became Oregon Revised Statute (ORS) 332.166-167. As directed

More information

C-NRPP Quality Control and Quality Assurance Manual for Radon Sampling and Analysis conducted by Radon Measurement Professionals and Laboratories

C-NRPP Quality Control and Quality Assurance Manual for Radon Sampling and Analysis conducted by Radon Measurement Professionals and Laboratories C-NRPP Quality Control and Quality Assurance Manual for Radon Sampling and Analysis conducted by Radon Measurement Professionals and Laboratories October 2018 C-NRPP/PNCR-C 1 (855) 722-6777 c-nrpp.ca Canadian

More information

Radon Measurement Survey Report. Rollins Elementary School 950 Kane Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Rollins Elementary School 950 Kane Street Aurora, Illinois Prepared For: Radon Measurement Survey Report Site: 950 Kane Street Aurora, Illinois 60505 Survey Dates: May 15, 2018 thru May 18, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois

More information

Radon Measurement Survey Report. Oak Park Elementary School 1200 Front Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Oak Park Elementary School 1200 Front Street Aurora, Illinois Prepared For: Radon Measurement Survey Report Site:July 5, 2018 1200 Front Street Aurora, Illinois 60505 Survey Dates: May 9, 2018 thru May 11, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora,

More information

Comprehensive Short-Term Radon Survey Report

Comprehensive Short-Term Radon Survey Report Environmental Works, LLC 2634 SE Steele St. Portland, OR. 97202 Phone: 503-719-6715 Fax: 503-972-1866 Email: Sebastian@eworksnw.com Comprehensive Short-Term Radon Survey Report Test Performed At: Trillium

More information

Quality Assurance Plan for Conducting Radon Measurements

Quality Assurance Plan for Conducting Radon Measurements Quality Assurance Plan for Conducting Radon Measurements 921 Pheasant Run Lindsborg, Kansas 67456 (785) 510-0000 info@clarityinspect.com getyourinspection.com page 1 of 18 Table of Contents A.1 Approval

More information

Design and Fabrication of New Radon Chamber for Radon Calibration Factor of Measurement

Design and Fabrication of New Radon Chamber for Radon Calibration Factor of Measurement International Journal of Scientific & Engineering Research, Volume 3, Issue 10, October-2012 1 Design and Fabrication of New Radon Chamber for Radon Calibration Factor of Measurement Murtadha S. Al-Nafiey,*

More information

Radon Measurement Survey Report. Waldo Middle School 56 Jackson Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Waldo Middle School 56 Jackson Street Aurora, Illinois Prepared For: Radon Measurement Survey Report Site: 56 Jackson Street Aurora, Illinois 60505 Survey Dates: May 8, 2018 thru May 10, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois

More information

AIR POLLUTION Uncertainty Exists in Radon Measurements

AIR POLLUTION Uncertainty Exists in Radon Measurements s Lx i A0 United States General Accounting Office Report to the Chairman, Committee on Science, Space, and Technology, House of Representatives Ictober 1989 AIR POLLUTION Uncertainty Exists in GAO/RCED-90-26

More information

Instrumentation. Post RDD Event Urban Reoccupancy. James P. Menge PE. The world leader in serving science

Instrumentation. Post RDD Event Urban Reoccupancy. James P. Menge PE. The world leader in serving science The world leader in serving science Instrumentation Post RDD Event Urban Reoccupancy James P. Menge PE Perception In the aftermath of a radiological emergency the public will see radiation and its potential

More information

835 S. Canyon Blvd., John Day, OR 97845 Phone: (541) 575-1349 Fax: (541) 575-3601 Robert Waltenburg-Superintendent waltenburgr@grantesd.k12.or.us Stacie Holmstrom Deputy Clerk holmstroms@grantesd.k12.or.us

More information

Portable Survey Instruments NISP-RP-01

Portable Survey Instruments NISP-RP-01 NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection NISP-RP-01 This is an industry document for standardizing radiation protection processes used by supplemental radiation protection technicians.

More information

Illinois Emergency Management Agency

Illinois Emergency Management Agency Illinois Emergency Management Agency Radon in Construction Patrick Daniels & Melinda Lewis 1 What is Radon? Radon is an indoor air pollutant. Radon is a colorless, odorless radioactive gas that comes from

More information

STUDY #3 IN A SERIES OF REPORTS ON RADON IN BC HOMES. Castlegar: COMMUNITY-WIDE RADON TESTING RESULTS AS PART OF ITS. PROGRAm

STUDY #3 IN A SERIES OF REPORTS ON RADON IN BC HOMES. Castlegar: COMMUNITY-WIDE RADON TESTING RESULTS AS PART OF ITS. PROGRAm STUDY #3 IN A SERIES OF REPORTS ON RADON IN BC HOMES Castlegar: COMMUNITY-WIDE RADON TESTING RESULTS AS PART OF ITS PROGRAm BC Lung Association The British Columbia Lung Association (BCLA) is one of the

More information

Radon Measurement Survey Report. Fred Rodgers Magnet Academy 501 College Avenue Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Fred Rodgers Magnet Academy 501 College Avenue Aurora, Illinois Prepared For: Radon Measurement Survey Report Site: 501 College Avenue Aurora, Illinois 60505 Survey Dates: May 16, 2018 thru May 18, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois

More information

SENSITIVE ENOUGH TO DETECT RUNOFF FROM SECRET NUCLEAR PLANTS

SENSITIVE ENOUGH TO DETECT RUNOFF FROM SECRET NUCLEAR PLANTS SENSITIVE ENOUGH TO DETECT RUNOFF FROM SECRET NUCLEAR PLANTS MODEL 1925 HEAVY WATER LEAK DETECTOR (HWLD) CONTINUOUS FLOW TRITIUM IN WATER SURVEY MONITOR MODEL 1925-HWLD TRUCK OR TRAILER MOUNT AVAILABLE

More information

Development of high sensitivity radon detectors

Development of high sensitivity radon detectors Nuclear Instruments and Methods in Physics Research A 421 (1999) 334 341 Development of high sensitivity radon detectors Y. Takeuchi *, K. Okumura, T. Kajita, S. Tasaka, H. Hori, M. Nemoto, H. Okazawa

More information

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection Level 3 Information Use NISP-RP-001 Industry Approval Date: September 14, 2018 This is an industry document for standardizing radiation protection

More information

INTERNATIONAL INTERCOMPARISON EXERCISE ON NATURAL RADIATION MEASUREMENTS UNDER FIELD CONDITIONS (IFC11) *

INTERNATIONAL INTERCOMPARISON EXERCISE ON NATURAL RADIATION MEASUREMENTS UNDER FIELD CONDITIONS (IFC11) * INTERNATIONAL INTERCOMPARISON EXERCISE ON NATURAL RADIATION MEASUREMENTS UNDER FIELD CONDITIONS (IFC11) * BOTOND PAPP 1, ALEXANDRA CUCOŞ (DINU) 1*, MIRCEA MOLDOVAN 1, ROBERT BEGY 1, TIBERIU DICU 1, DAN

More information

Dealing With RADON in Real Estate Transactions

Dealing With RADON in Real Estate Transactions This document has been reproduced by the concerned professionals at: Colorado Department of Public Health and Environment March 2002 Dealing With RADON in Real Estate Transactions Colorado Department of

More information

RADON CONCENTRATIONS AFFECTED BY DIFFERENT FACTORS IN TWO OFFICE BUILDINGS. Raimo Halonen, Pirjo Korhonen, Pentti Kalliokoski and Helmi Kokotti

RADON CONCENTRATIONS AFFECTED BY DIFFERENT FACTORS IN TWO OFFICE BUILDINGS. Raimo Halonen, Pirjo Korhonen, Pentti Kalliokoski and Helmi Kokotti Radon in the Living Environment, 25 RADON CONCENTRATIONS AFFECTED BY DIFFERENT FACTORS IN TWO OFFICE BUILDINGS Raimo Halonen, Pirjo Korhonen, Pentti Kalliokoski and Helmi Kokotti Department of Environmental

More information

RADON SCREENING SURVEY FOLLOW-UP SPRINGBROOK HIGH SCHOOL

RADON SCREENING SURVEY FOLLOW-UP SPRINGBROOK HIGH SCHOOL RADON SCREENING SURVEY OLLOW-UP SPRINGBROOK HIGH SCHOOL, Silver Spring, Maryland 20904 EXECUTIVE SUMMARY Date of Test Report: 9 ebruary 2016 Round of Testing: Initial ollow-up Post Remediation # rooms

More information

- For Continuous Radon Monitoring (CRM) Systems - Ultra Low Power Requirement

- For Continuous Radon Monitoring (CRM) Systems - Ultra Low Power Requirement RN53 Radon Detector RN53 - For Continuous Radon Monitoring (CRM) Systems - Ultra Low Power Requirement Description The RN53 Radon Detector operates on the method of electrostatic collecting of the radon

More information

RADON LAZERWEB SERVICES

RADON LAZERWEB SERVICES RADON LAZERWEB SERVICES WWW.LAZERWEBSITES.COM Contents Overview...2 Radon is estimated to cause thousands of lung cancer deaths in the U.S. each year...2 Radon is a cancer causing, radioactive gas...2

More information

Sensitivity to Thoron on Passive Radon Detectors

Sensitivity to Thoron on Passive Radon Detectors Sensitivity to Thoron on Passive Radon Detectors S. Tokonami 1, H. Yonehara 1, T. Sanada 2, M. Yang 3, M. Furukawa 1 and Y. Yamada 1 1 National Institute of Radiological Sciences, Chiba 263-8555, Japan

More information

Radiation Safety and Equipment Considerations. Bonnie Meilner Regional Sales Manager LAURUS Systems Inc.

Radiation Safety and Equipment Considerations. Bonnie Meilner Regional Sales Manager LAURUS Systems Inc. Radiation Safety and Equipment Considerations Bonnie Meilner Regional Sales Manager LAURUS Systems Inc. bonnie.meilner@laurussystems.com COPYRIGHT LAURUS SYSTEMS INC - 2013 Why do you need Radiation Detectors

More information

CLACKAMAS EDUCATION SERVICE DISTRICT HEALTHY AND SAFE SCHOOLS PLAN

CLACKAMAS EDUCATION SERVICE DISTRICT HEALTHY AND SAFE SCHOOLS PLAN CLACKAMAS EDUCATION SERVICE DISTRICT HEALTHY AND SAFE SCHOOLS PLAN March 17, 2017 Introduction Clackamas Education Service District has developed this model Healthy and Safe Schools Plan to comply with

More information

Detectors used in the intercomparison

Detectors used in the intercomparison Detectors used in the intercomparison The second radon-in-field international intercomparison for passive measurement devices: dwellings and workplaces 21 22 september 2017 Campus Bovisa Politecnico di

More information

COUNTING ROOM EQUIPMENT RCT STUDY GUIDE

COUNTING ROOM EQUIPMENT RCT STUDY GUIDE LEARNING OBJECTIVES: 2.19.01 Describe the features and specifications for commonly used laboratory counters or scalers: a. Detector type b. Detector shielding c. Detector window d. Types of radiation detected

More information

film flow, ultrasonic, and microwave. The engineering development effort builds upon the

film flow, ultrasonic, and microwave. The engineering development effort builds upon the 9. e,.-..- n FLUID-BASED RADON MITIGATION TECHNOLOGY DEVELOPMENT FOR INDUSTRIAL APPLICATIONS K. V. tiu, J. D. Gabor, R. E. Hoitz, and K. C. Gross Argonne National Laboratory 9700 S. Cass Ave. Argonne,

More information

ALL RADON TESTS WERE SIGNIFICANLY BELOW

ALL RADON TESTS WERE SIGNIFICANLY BELOW Radon Testing Results for Multifily Radon Testing 4pCi/L and above is considered an action level At this time, radon levels at tested locations were considered low and safe for this building. ALL RADON

More information

Via Umberto Giordano, Padova Tel Fax VERSIONS ACCURACY

Via Umberto Giordano, Padova Tel Fax VERSIONS ACCURACY DOWNLOADS DESCRIPTION BATTERY LIFE Approximately 1.5 years of continuous monitoring 3 replaceable AAA batteries DISPLAY 1-day, 7-day, and long-term average radon level FUNCTIONS Reset button Mode button

More information

Radon Basics for Building Officials PATRICK DANIELS IEMA RADON PROGRAM

Radon Basics for Building Officials PATRICK DANIELS IEMA RADON PROGRAM Radon Basics for Building Officials PATRICK DANIELS IEMA RADON PROGRAM What is Radon? Radon is an indoor air pollutant. Radon is a colorless, odorless radioactive gas that comes from naturally occurring

More information

RADON IN SCHOOL WELL WATER: CASE STUDIES AND MITIGATION IMPLICATIONS

RADON IN SCHOOL WELL WATER: CASE STUDIES AND MITIGATION IMPLICATIONS RADON IN SCHOOL WELL WATER: CASE STUDIES AND MITIGATION IMPLICATIONS Alan J. Siniscalchi, Zygmunt F. Dembek, Sarah J. Tibbetts, Xaviel Soto, and Amjad Mahmood State of Connecticut Department of Public

More information

MCPS RADON TESTING. Executive Summary: Festival Center. Date of Test Report: 4/15/2016 Round of Testing: Initial Follow-up Post Remediation

MCPS RADON TESTING. Executive Summary: Festival Center. Date of Test Report: 4/15/2016 Round of Testing: Initial Follow-up Post Remediation E NGINEERS P LANNERS S CIENTISTS C ONSTRUCTION M ANAGERS 936 RIDGEBROOK ROAD SPARKS, MD 21152 410-316-7800 (FAX) 410-316-7935 MCPS RADON TESTING Executive Summary: Festival Center Date of Test Report:

More information

Dealing With RADON in Real Estate Transactions

Dealing With RADON in Real Estate Transactions This document has been reproduced by the concerned professionals at: Wyoming Department of Health Revised 2005 Dealing With RADON in Real Estate Transactions Wyoming Department of Health Wyoming Radon

More information

HEALTH AND SAFETY MANUAL

HEALTH AND SAFETY MANUAL HEALTH AND SAFETY MANUAL Title: Ionizing Radiation Approved by: Greg Savoy Rev. 3/1/13 1.0 Purpose The purpose of this safety policy is to establish guidelines for the protection and safety of Compay employees

More information

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor NEX-BETA-ABG FACILITY Drinking Water Safety Monitor FEATURES: DETECTS ALPHA, BETA AND GAMMA RADIATION AVAILABLE IN PORTABLE OR INSTALLED VERSION MEASURES AT OR BELOW EPA/DHS PAG LEVELS PROTECTIVE ACTION

More information

A new personal dosemeter for the individual monitoring of exposure to radon gas

A new personal dosemeter for the individual monitoring of exposure to radon gas A new personal dosemeter for the individual monitoring of exposure to radon gas Rosabianca Trevisi a*, Paolo Orlando b, Giuseppe Arcovito b, Francesco Cardellini c, Elisabetta Fonti b, Claudia Orlando

More information

1 SCOPE 2 OVERVIEW 3 NORMATIVE REFERENCES

1 SCOPE 2 OVERVIEW 3 NORMATIVE REFERENCES Table of Contents 1 SCOPE... 2 2 OVERVIEW... 2 3 NORMATIVE REFERENCES... 2 4 DEFINITIONS & ACRONYMS... 4 5 UNITS & CONVERSIONS... 6 6 CLASSIFICATION OF INSTRUMENTS AND INSTRUMENT SYSTEMS... 7 7 PERFORMANCE

More information

HISTORY OF SOIL-GAS RADON CONCENTRATION MEASUREMENTS IN THE CZECH REPUBLIC

HISTORY OF SOIL-GAS RADON CONCENTRATION MEASUREMENTS IN THE CZECH REPUBLIC HISTORY OF SOIL-GAS RADON CONCENTRATION MEASUREMENTS IN THE CZECH REPUBLIC Martin Neznal & Matěj Neznal RADON v.o.s. Novákových 6, 180 00 Praha 8, Czech Republic radon@comp.cz www.radon.eu LATIN AMERICAN

More information

Maximize safety and productivity. Thermo Scientific Nuclear Power Radiation Detection and Monitoring Solutions

Maximize safety and productivity. Thermo Scientific Nuclear Power Radiation Detection and Monitoring Solutions Maximize safety and productivity Thermo Scientific Nuclear Power Radiation Detection and Monitoring Solutions Monitoring solutions to optimize safety, efficiency and compliance Our years of expertise and

More information

Testing for Elevated Radon in Oregon Schools Protocol and Plan

Testing for Elevated Radon in Oregon Schools Protocol and Plan Testing for Elevated Radon in Oregon Schools Protocol and Plan For the 1130 S Ivy Canby OR 97013 Kelsay Environmental Building Consulting Services, Corp. CCB#196361/ESB #8603 TABLE OF CONTENTS INTRODUCTION

More information

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS UNDERSTANDING, ACCELERATED TSI SETS THE STANDARD FOR PARTICLE COUNTING Performance Semiconductor, hard disk drive, and flat panel manufacturers

More information

Relevant Radon properties

Relevant Radon properties Relevant Radon properties Radon is a natural gas and has a half life of 3.8 days. This means that if a box was full of radon gas, half of it would have decayed into something else after 3.8 days. It has

More information

Radiation Protection Program Updates

Radiation Protection Program Updates Radiation Protection Program Updates SWEP Capital Chapter Seminar November 5, 2015 Joseph Melnic Radiation Control Division Manager Robert Lewis Radon Division Manager Tom Wolf, Governor John Quigley,

More information

Radon Detection Specialists, Inc. Love the Lungs You re With

Radon Detection Specialists, Inc. Love the Lungs You re With 630-325-4443 800-244-4242 kws@radonresults.com Commercial Radon Survey Report Client: Pleasantdale School District 107 8100 School Street La Grange, Illinois 60525 Survey Date: August 27, 2014 to August

More information

Introduction...1 Specifications... 1 Limitations... 1

Introduction...1 Specifications... 1 Limitations... 1 Table of Contents Introduction...1 Specifications... 1 Limitations... 1 New Algorithms...2 Regions of Interest... 3 New Algorithm ROIs... 3 Calibration... 5 Update Interval... 5 K Factor... 5 Subscripts...

More information

Using downhole probing for real-time grade estimation for uranium exploration and mining

Using downhole probing for real-time grade estimation for uranium exploration and mining February 2015 Using downhole probing for real-time grade estimation for uranium exploration and mining Andrew Fitzpatrick Chief Geophysicist cameco.com Radiation 101 2 Using downhole probing for Uranium

More information

SENSITIVE ENOUGH TO DETECT RUNOFF CHANGES IN GROUNDWATER TRITIUM PLUMES

SENSITIVE ENOUGH TO DETECT RUNOFF CHANGES IN GROUNDWATER TRITIUM PLUMES SENSITIVE ENOUGH TO DETECT RUNOFF CHANGES IN GROUNDWATER TRITIUM PLUMES MODEL 77 CONTINUOUS FLOW TRITIUM IN WATER SURVEY MONITOR WHEELED CART, TRUCK OR TRAILER MOUNT ALSO AVAILABLE sales@overhoff.com :

More information

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc. Commercial Survey Report Client: Community Consolidated School District 181 Site Address: Elm School 6010 S Elm St Hinsdale, IL 60521 Survey Date: April 9, 2012 to April 11, 2012 Initial Test RDS-R-002

More information

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions. Personal Alpha/Beta Continuous Air Monitor (CAM) The pocamon (personal online continuous air monitor) monitors continuously the breathing air to detect airborne radioactive aerosols (LLRD). Typical application

More information

Sergey Kiselev. SRC Federal Medical Biophysical Center

Sergey Kiselev. SRC Federal Medical Biophysical Center Sergey Kiselev SRC Federal Medical Biophysical Center Uranium Thorium 1940s -uranium/thorium geological maps. Epidemiological studies U-mine cohort studies Place Zheltoreche nsk Uchkuduk Country Type of

More information

Conducting and Assessing Radon Surveys in Schools & Commercial Buildings

Conducting and Assessing Radon Surveys in Schools & Commercial Buildings Conducting and Assessing Radon Surveys in Schools & Commercial Buildings CIHC 2015 Annual Conference December 7, 2015 Gustavo A. Delgado, Ph.D. California Radon Measurement Provider Forensic Analytical

More information

2.3 Definitions, General Provisions, and Radon Standards

2.3 Definitions, General Provisions, and Radon Standards 216-RICR-50-15-2 TITLE 216 DEPARTMENT OF HEALTH CHAPTER 50 ENVIRONMENTAL HEALTH SUBCHAPTER 15 HEALTHY ENVIRONMENT PART 2 Radon Control 2.1 Authority These regulations are promulgated pursuant to the authority

More information

THE PRESENT STATUS OF THE RADON PROGRAM IN THE UNITED STATES OF AMERICA. Andreas C. George and Nancy Bredhoff

THE PRESENT STATUS OF THE RADON PROGRAM IN THE UNITED STATES OF AMERICA. Andreas C. George and Nancy Bredhoff Radon in the Living Environment, 012 THE PRESENT STATUS OF THE RADON PROGRAM IN THE UNITED STATES OF AMERICA Andreas C. George and Nancy Bredhoff Radon Testing Corporation of America 2 Hayes Street, Elmsford,

More information

RULES AND REGULATIONS FOR RADON CONTROL

RULES AND REGULATIONS FOR RADON CONTROL RULES AND REGULATIONS FOR RADON CONTROL [R23-61-RC] STATE OF RHODE ISLAND AND PROVIDENCE PLANTATIONS DEPARTMENT OF HEALTH AUGUST 1994 AS AMENDED January 2002 (re-filing in accordance with the provisions

More information

Pennsylvania Citizen s Guide to Radon. Test your home for radon it is easy and inexpensive.

Pennsylvania Citizen s Guide to Radon. Test your home for radon it is easy and inexpensive. EPA Recommends: Test your home for radon it is easy and inexpensive. Fix your home if your radon level is 4 picocuries per liter (pci/l) or higher. Radon levels less than 4 pci/l still pose a risk and

More information

LONG TERM RADON TEST KIT FOR RADON IN AIR INSTRUCTIONS AND DATASHEET

LONG TERM RADON TEST KIT FOR RADON IN AIR INSTRUCTIONS AND DATASHEET INSTRUCTIONS AND DATASHEET v1.0 What is Radon? Radon is an odourless, colorless, radioactive gas. Radon has been found in homes all over the world. It comes from the natural breakdown of uranium found

More information

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc. Commercial Radon Survey Report Client: Community Consolidated School District 181 Site Address: Prospect School 130 N Prospect Clarendon Hills, IL 60514 Survey Date: April 23, 2012 to April 25, 2012 Initial

More information

RADON What You Need to Know

RADON What You Need to Know RADON What You Need to Know Radiation Protection Bureau Health Canada November 2016 WHAT IS RADON Radon is a radioactive gas that is produced naturally by the breakdown of uranium in the ground. Radon

More information

Ramon 2.2 Radon-Monitor

Ramon 2.2 Radon-Monitor Ramon 2.2 Radon-Monitor Applications Measurement Modes - Technology - Quality Extratech Engineering, Technology, Software & Training - by 3DLiFe srl Via Torraca, 76-85100 Potenza (PZ) Tel/Fax. (+39) 0971.21.432

More information

Environmental Resources Group, LLC (ERG) has completed the Radon Testing for the referenced property in Ann Arbor, Michigan.

Environmental Resources Group, LLC (ERG) has completed the Radon Testing for the referenced property in Ann Arbor, Michigan. August 8, 2013 Mr. Richard Higgins Norstar Development USA, L.P. 733 Broadway Albany, New York 12207 Re: Radon Testing Green Baxter 1737 Green Road, Ann Arbor, Michigan ERG Project 1127.004 Dear Mr. Higgins,

More information

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor FEATURES: HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS WORLD S ONLY PAG-LEVEL WATER MONITOR MEASURES AT OR BELOW EPA/DHS PAG LEVELS (EPA s PROTECTIVE ACTION GUIDELINE LEVELS) REAL TIME, IN-LINE, CONTINUOUS

More information

Dynamic Radon Detection Over Measurement

Dynamic Radon Detection Over Measurement Dynamic Radon Detection Over Measurement Nuclear Engineer, specialised in detection of nuclear particles, instrumentations and radioprotection. Person in charge of radioprotection. Worked for nuclear industries

More information

Guide for Radon Measurements in Residential Dwellings (Homes)

Guide for Radon Measurements in Residential Dwellings (Homes) Guide for Radon Measurements in Residential Dwellings (Homes) Health Canada is the federal department responsible for helping Canadians maintain and improve their health. We assess the safety of drugs

More information

Limestone Cements. Why are we doing this? What are they? What s in it for you? Limestone Cements, Holcim (US) Inc.

Limestone Cements. Why are we doing this? What are they? What s in it for you? Limestone Cements, Holcim (US) Inc. Limestone Cements Why are we doing this? What are they? What s in it for you? Limestone Cements, 2014-03-31 2014 Holcim (US) Inc. NCC Limestone Presentation Cements Why are we doing this? Limestone Cements,

More information

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc. Commercial Radon Survey Report Client: Community Consolidated School District 181 Site Address: Walker School 120 S Walker Clarendon Hills, IL 60514 Survey Date: April 25, 2012 to April 27, 2012 Initial

More information

FOCUS ON TOMORROW. Radon in British Columbia Work Places RESEARCH FUNDED BY WORKSAFEBC. November Principal Investigator/Applicant Dr.

FOCUS ON TOMORROW. Radon in British Columbia Work Places RESEARCH FUNDED BY WORKSAFEBC. November Principal Investigator/Applicant Dr. FOCUS ON TOMORROW RESEARCH FUNDED BY WORKSAFEBC Radon in British Columbia Work Places November 2009 Principal Investigator/Applicant Dr. Ray Copes RS2006-DG09 Radon in British Columbia Work Places A Report

More information

INTERNATIONAL JOURNAL OF RESEARCH SCIENCE & MANAGEMENT

INTERNATIONAL JOURNAL OF RESEARCH SCIENCE & MANAGEMENT [Kim* et al., 4(2): February, 17] ISSN: 234-97 PERFORMANCE IMPROVEMENT OF RADON COUNTERS 1 Yong-Cheol Kim, *2 Gyu-Sik Kim 1,2 Professor, Dept. of Electrical and Computer Eng., University of Seoul, Korea

More information