Property of Monitronics Inc

Size: px
Start display at page:

Download "Property of Monitronics Inc"

Transcription

1 Enter Program Program Location 1. Hold 8 key for 3 seconds, keypad will beep 2. Enter , display should show dash on display 1. Press [B/A] key display will show 3 dashs 2. Enter 3-digit location (use B/A for any 0) 3. Value currently programmed in location will display 4. Scroll Value UP with 4 key, scroll Value DOWN with 7, blank location with 5 5. When display shows desired Value press 2 to move to next location (Or B/A + 3-digit location to move to elsewhere) Programming with LCD layout is slightly different LCD Keypads 1 scrolls left 2 scrolls right 5 scrolls data up 9 scrolls data down Exit Program Enable Panics Lockout Bypass 1. Hold 8 key 3 seconds, keypad will flash and beep 2. Enter , display should return to normal Open Keypad cover, cute Jumper "E" (bottom left jumper, clearly marked) 1. Run jumper to pins on large chip marked X (see wiring diagram) 2. Press 9 for 3 seconds, then 8 for 3 seconds and enter LED display should show ---, remove jumper and program normallly (wire MUST be removed to view or change locations) Report Codes Zone 1 31 Duress 21 to 29 Zone 2 32 Keypad Fire Panic 19 Zone 3 33 Keypad Police Panic 29 Zone 4 34 Keypad Medical Panic 49 Zone 5 35 Low Battery 78 Zone 6 36 Low Battery Restoral 98 Zone 7 37 AC Failure 79 Zone 8 38 AC Failure Restoral 99 Zone 9 39 Fire Trouble 76 Zone Fire Restore 96 Zone Smoke Detector* 16 or 18 Zone Cancel D1 to D8 Zone Opening 5 + User Zone Closing 6 + User Zone Test/Download Complete EE Zone Zone Restores 9 + Zone IF something screws up power down then up, you have 30 seconds to get into programming

2 < Report Options > To program REPORT OPTIONS in locations 166 to 185 see below Diagram Add location together and enter sum in location Example: Enable Reporting for Zones 1 to 6, Keypad Panic, Fire, Duress, Fire Trouble, AC Fail and Low Bat 1. Press B/A then to move to Location Add ZONE 1 (1) + ZONE 2 (2) + ZONE 3 (4) + ZONE 4 (8) = 15 or F, enter the F in location Press 2 key to move to Add Zone 5 (1) + Zone 6 (2) + Keypad Panic (8) = 11 (B), enter the B in location Press 2 key to move to Add FIRE ZONE (1) + AMBUSH (2) + FIRE TROUBLE (4) = 7, enter the 7 in location Press 2 key to move to Add AC FAIL (2) + LOW BAT (4) = 6, enter the 6 in location 169 Report Enable Zone 1 to 4 I F _I Fire/Duress, Fire Trouble I 7 I Report Enable Zones 5, 6 & Panic I B _I AC Fail/Low Bat Trouble I 6 I Restores Enabled I I I Misc Restores I I I (Blank out this section) (Blank out this section) Zone Restores I I I (Blank out this section) < Report Codes > Zone 1 Report Code I 3 I 1 I Keypad Police Panic I 2 I 9 I Zone 2 Report Code I 3 I 2 I Fire Panic/Smoke Detector* I 1 I 6 I Zone 3 Report Code I 3 I 3 I Hostage/Duress I 2 I 6 I Zone 4 Report Code I 3 I 4 I Fire Trouble I 7 I 6 I Zone 5 Report Code I 3 I 5 I Day Zone Trouble I I I Zone 6 Report Code I 3 I 6 I Test Timer I I I Not Used I I I AC Failure I 7 I 9 I Low Battery I 7 I 8 I (I I I = Blank out Locations with 5 key) *Fire Panic and Smoke Detector share signal if Smoke Detector uses dedicated Fire Zone < Restore Codes > Zone 1 Restore I I I Fire Panic/Smoke I I I Zone 2 Restore I I I Not Used I I I Zone 3 Restore I I I Fire Trouble I I I Zone 4 Restore I I I Medical Panic I 4 I 9 I Zone 5 Restore I I I Not Used I I I Zone 6 Restore I I I AC Trouble Restore I I I Low Battery Restore I I I (I I I = Blank out Locations with 5 key)

3 < Opening/Closings/Cancel > Closing User 1 I I I Opening User 1 I D I 1 I Closing User 2 I I I Opening User 2 I D I 1 I Closing User 3 I I I Opening User 3 I D I 1 I Closing User 4 I I I Opening User 4 I D I 1 I Force Arm I I I (These are Cancels, see also section 179) Select User Closings I I Select User Openings I I (I I I = Blank out Locations with 5 key) < Account Numbers > Telephone Number 1 (Last 4 of Account must be entered in each section) Group 1 Account Group 2 Account Open/Close Account I? I? I? I? I I? I? I? I? I I I I I I Telephone Number 2 (Leave Blank) Group 1 Account Group 2 Account Open/Close Account I I I I I I I I I I I I I I I < Phone Numbers > Report Format Phone 1 I 9 I 2 I First Digit Second Digit Blank = Ademco/Silent Knight Slow Blank = Extended or Single Digit 1 = Sescoa, Vertex, DCI, Franklin 1 = Single Digit 2 = Radionics Fast 2 = 2-Digit (4/2) 3 = Silent Knight Fast 4 = Sumcheck 4 = Radionics, DCI, Franklin Slow 5 = Universal Hi Speed 8 = 2300 Handshake (Add this to above numbers) Receiver 1 Options I I I (Add D in 114 if delay needed to dial out) (Add 9 in 115 if 9 is needed to dial out) Receiver 1 Phone I_ E_ I I I I I I I I I I I I I I I I Report Format Phone 2 I I I (Leave blank) Receiver 2 Options I I I (Leave blank) Receiver 2 Phone I_ E_ I I I I I I I I I I I I I I I I Rings before Download I 9 I (9 rings until Answer) 269 Download Phone 1 I I I I I I I I I I I I I I I I I Download Phone 2 I I I I I I I I I I I I I I I I I

4 < Misc Functions > To program sections 084 to 216 see below Diagram Add location together and enter sum in location Example: Program Zones 1, 3 4, 5 and 6 for Door Chime 1. Press B/A then B/A again then 8 8 to enter Location Add Zone 1 (1) + Zone 2 (2) + Zone 4 (8) = 11 or B, enter B in location Press 2 key to move to Add Zone 5 (1) + Zone 6 (2) = 3, enter 3 in location 089 Swinger Shutdown I F I 3 I (Swinger enabled on all Zones) No EOL Zone Resistors I I I (F 3 = No EOL all Zones, Blank = EOL all zones) Chime Zones 1 to 6 I I I (Turns on/off chimes per zone) Never Arm I I I (Leave blank) PIR Zone I I I (Program PIR zones here. also see ) Untimed Output to Lug E15 I F I B _I I I (Normally not programmed) Keypad Sounder on Alarm I I I (Leave blank) Day Zone I I I (Leave blank) Priority Zone W/Bypass I I I (Leave blank) Priority Zone I F I 3 I (Default = F 3, leave alone) Remove Auto-Bypass I I I (Leave blank) Selective Bypass I F I 3 I (Default = F 3, leave alone) Group Bypass I? I? I (Any zone here will bypass by B/A key twice) Hr Protection I I 8 I (Use if Hold-Up buttons on a zone) Auto Reset I F I D I (Default = F D, leave alone) Entry/Exit Delay 1 Zones I? I? I (Program which zones are Delay 1) Entry/Exit Delay 2 Zones I? I? I (Program which zones are Delay 2) Interior Follower Zones I? I? I (Program PIR zones here. also see ) Abort Delay per Zone I I I (Leave blank) Burglary Output per Zone I F I B I (FB = Audible Keypad Panic, F3 = Silent) Timed Negative Output I I I (Leave blank) ms Loop Response I I I (Leave blank) ms Loop Response I I I (Leave blank)

5 Hostage/Duress Code User Program Code Installer/Dealer Code < User Codes > I 9 I 9 I I 1 I 2 I 3 I 4 I 5 I 6 I This allows customer to change User codes, leave at default I 4 I 5 I 6 I 7 I 8 I 9 I User Code 1 I 1 I 2 I 3 I 4 I User Code 2 I I I I I User Code 3 I I I I I User Code 4 I I I I I User Code 5 I I I I_ 7 I User Code 6 I I I I I User Code 7 I I I I I User Code 8 I I I I I User Codes can be 1, 2, 3 or 4 digits, If User Code 5 is Quick Arm program as 7, customer can Arm system by pressing 7, do NOT make it anything else or it will screw up other functions! < Misc Options > Add each section, place total in box (Example: = 13 or "D") I I = Blank Out with 5 key I 4 I ç 1 = Display Day Zone/Reset I 2 I ç 1 = Audible Test on Arming = Reserved = Auto-Reset after Timeout 4 = User 5 Quick Arm 4 = Reserved 8 = User 5 Report as User 1 8 = Reserved I I ç 1 = User 5 Service Code I 5 I ç 1 = Pulsing Fire = Disable Day Zone Report = Disable Key 9 Reset Fire Zone 4 = Users 6,7,8 Report as 2,3,4 4 = Enable Keypad Tactical Beeps 8 = Reserved 8 = Reset Test Timer on any Alarm Report I 1 I ç 1 = Disable Low Battery Display* I 6 I ç 1 = Disable Fault Find = Reserved = Enable Keypad Panic 4 = Disable Callback Download 4 = Enable Communicator Test 8 = Disable Function 6 Download 8 = Disable Bell Test I 1 I ç 1 = Watch on With Group Bypass I 1 I ç 1 = Display any Bypass = Chime On with Group Bypass = Reserved 4 = Display Open Zones 4 = Inc Manl Bypass in Force Arm/Status 8 = Disable Display Bypass 8 = Keyswitch Input on Zone 5 I D I ç 1 = Enable Download w/ans Machine I 6 I ç 1 = Enable User 8 to PGM Lug = Reserved = Enable PGM on E/E Delay 4 = Enable Keypad Fire Panic* 4 = Fail to Communicate on PGM Lug 8 = Enable Keypad Aux/Medical Panic* 8 = Keypad Sounder on PGM Lug I 2 I ç 1 = Touchtone Dialing I I ç 1 = Ground Start on PGM Lug = Touchtone with Rotary Backup = Armed LED on PGM Lug 4 = Backup Reporting 4 = Keypad Aux on PGM Lug 8 = Double Reporting 8 = Audio Verification on PGM Lug I 1 I ç 1 = Opening after Alarm (see 070 to 077) *Panics only work if Jumper E on Keypad is cut = Force Arm (Jumper E found at bottom left in back of Keypad) 4 = Status Report ** Panel tends to display low battery if siren sounds 8 = Split Report for any length of time

6 < System Times > Entry/Exit Times found by dividing desired time by 16 Enter 1st digit of resut in second box and 2nd digit of result in 1st box (wierd ain't it?) Sensor Watch I _I I (Leave both blank, not used) Exit Delay I C I 3 I (60 seconds) Entry Delay 1 I E I 1 I (30 seconds) Entry Delay 2 I E I 1 I (30 seconds) Burg Timeout I 6 I I (6 minutes, leave 2nd entry blank) Fire Timout I F I I (Unlimited, leave 2nd entry blank) Chime Duration I 4 I I (1/2 second Chime, leave 2nd entry blank) Abort Delay I I I (Leave both blank, not used) Test Timer I I I (Leave both blank, not used) Auto Download ID I I I (Leave both blank, not used) Callback Select I I (Leave blank, not used) 254

7

8 Monitronics Napco 1000e Quick Reference Guide Monitoring and Service call Arming With STATUS light steady enter User Code, ARM light should turn on indicating system is armed If display shows a flashing P system was armed with a zone open Disarming / Silencing an Alarm Instant Doors Zone Bypassing User Codes Enter 4-digit Code If silencing alarm turn off siren with User Code then hold 9 for three seconds to stop any flashing display Before or after arming system press 4 for 3 seconds STATUS light will rapidly flash and all entry doors will now be instant All zones return to normal when system is disarmed. Press [B/A] + Zone to bypass (1 to 6), BYPASS light will turn on, arm system normally When system is disarmed all bypassed Zones will return to normal. Press 8 for 3 seconds (keypad will beep) Enter User Programming Code (ARM, STATUS and BYPASS lights flash and keypad rapidly beeps) Enter User to add or change (1 to 8) Enter new 3 to 4-digit User Code When finished press [B/A] twice to exit To erase a code follow above steps but press [B/A] twice instead of entering a code Door Chimes Press 5 for 3 seconds, repeat this to turn off chimes Smoke Detector Reset Trouble Light Panic Buttons Silence siren with User Code Press 9 for 3 seconds, smoke detector should reset With any internal problem ARM, STATUS and BYPASS lights will flash and a number will appear 1 = Power Failure: System is operating on Backup Battery 2 = Low Battery: Backup Battery is low and needs to either recharge or be replaced. 3 = Failure to Communicate: System cannot communicate with Monitoring Station Press 9 and # for Fire, [*/P] and # for Police, [B/A] and # for Medical Note: You may have to arm and disarm system to turn off siren after using Panic Buttons

Property of Monitronics Inc

Property of Monitronics Inc Enter Program Press CODE key + * + 2468 + 1 (also try 2121) Installer Options Move to location Program location Exit Program Default Panel Hex Program Code + * + Installer Code + 1 = Enter Programming

More information

First Alert 1200C Installer Notes M. Leuck

First Alert 1200C Installer Notes M. Leuck First Alert 2C Installer Notes M. Leuck. Programming can done by standard keypads 2. Enter programming with Installer Code + 8 + + 3. Another method of entering programming: Power system down, then back

More information

GEM-P800 Programming Instructions

GEM-P800 Programming Instructions NOTE After 15 minutes of keypad inactivity the keypad will emit a steady tone indicating the panel has been left in Dealer Program Mode Enter Dealer Code to exit or press the key to return to Dealer Program

More information

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION... 2 STANDARD AND OPTIONAL PARTS LIST... 2 PARTS DIAGRAM... 3 TERMINAL DRAWING AND SPECIAL NOTES...

More information

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION...2 STANDARD AND OPTIONAL PARTS LIST...2 FEATURE DEFINITIONS...3 TERMINAL DRAWING AND SPECIAL NOTES...4

More information

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. TABLE OF CONTENTS... P.1 2. GENERAL DESCRIPTION... P.2... 3. STANDARD AND OPTIONAL PARTS LIST... P.2... 4. FEATURE

More information

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96 Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96 XL-2G Gold Product Overview 7 Zones (6 programmable + panic or keyswitch zone) Fast Loop Response

More information

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION...P.2 2. STANDARD AND OPTIONAL PARTS LIST...P.2 3. FEATURE DEFINITIONS...P.3 4. TERMINAL DRAWING AND

More information

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION... 2 2. STANDARD AND OPTIONAL PARTS LIST... 2 3. FEATURE DEFINITIONS... 3 4. TERMINAL DRAWING AND SPECIAL

More information

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E... 5$1*(5( DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS General Description... 2 Standard and Optional Parts List... 2 Feature Definitions... 3 Comments about the 8600E... 4 Terminal

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING -961212-0004 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. ( 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2) Connect

More information

TABLE OF CONTENTS TABLE OF CONTENTS 1

TABLE OF CONTENTS TABLE OF CONTENTS 1 TABLE OF CONTENTS TABLE OF CONTENTS 1 FEATURES 2 Keypad Programmable... 2 EEPROM Memory... 2 Static/Lightning Protection... 2 Supervision... 2 Operation... 2 SPECIFICATIONS 2 PC1550 Control Panel... 2

More information

GEM-P800. Control Panel/Communicator. Installation Instructions

GEM-P800. Control Panel/Communicator. Installation Instructions GEM-P800 Control Panel/Communicator Installation Instructions NAPCO 2002 WI850C 9/02 WI850C GEM-P800 Installation Instructions Table of Contents General Information GEM-P800 Features General Information...

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING 48ESEP-01 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2)

More information

SECURITY SYSTEM 4110DL. Programming Form Programming Form Programming Form 4110DL-PRV3 10/96

SECURITY SYSTEM 4110DL. Programming Form Programming Form Programming Form 4110DL-PRV3 10/96 SECURITY SYSTEM 4110DL Programming Form Programming Form Programming Form 4110DL-PRV3 10/96 4110DL PROGRAMMING FORM FIELD FUNCTION [ ] = Default Value SYSTEM OPTIONS (*20-*28) *20 MASTER SECURITY CODE

More information

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide Digiplex System V2.14 / V2.2ACC Control Panel Programming Guide Table of Contents Getting Started...2 What Do I Do First?...2 How Do I Program the Control Panel?...2 Single Digit Entry Method...2 Multiple

More information

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX PROGRAMMING GUIDE SPECTRA CONTROL PANELS V1.2 1725, 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX TABLE OF CONTENTS HOW DO I PROGRAM THE SYSTEM?... 4 Single Digit Data Entry Method (Hexadecimal

More information

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover TABLE OF CONTENTS FEATURES 2 SPECIFICATIONS 2 INSTALLATION 3 Mounting the Panel... 3 Mounting the Keypad... 3 Auxiliary Power Connection... 3 PGM Terminal Connections... 3 Bell/Siren Connection... 3 Keypad

More information

GEM-P801 Control Panel/Communicator For use with the GEM-RP8 or the GEM-K800 Keypads. Installation Instructions

GEM-P801 Control Panel/Communicator For use with the GEM-RP8 or the GEM-K800 Keypads. Installation Instructions 333 Bayview Avenue Amityville, New York 11701 For Sales and Repairs, (800) 645-9445 For Technical Service, (800) 645-9440 Publicly traded on NASDAQ Symbol: NSSC GEM-P801 Control Panel/Communicator For

More information

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION...P.2 2. STANDARD AND OPTIONAL PARTS LIST...P.2 3. FEATURE DEFINITIONS...P.3 4. TERMINAL DRAWING AND

More information

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming Master Code The 4 digit Master Code is used for arming and disarming the system, for programming additional access codes, and for changing other features. The Master Code will be supplied to you by your

More information

Radionics D4112 Program Sheet

Radionics D4112 Program Sheet Programming only by downloading, 5200 Programmer or 5100 "Wand" Programmer Plug programmer in and momentarily short Reset Pin to Terminal 25 to enable program mode 1. Account Account # I I I I I (0 to

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING -961212-0004 SOFTWARE VERSI 3.10 CTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2)

More information

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual WIC-16Z4P WIC-5Z2P Installation & Operation User Manual Page : 1/34 INDEX # Function Page 1 Abort Current Communication and Clear Reporting Queue (*59) 13 2 Abort Current Communications (*59) 10 3 Account

More information

Control/Communicator Installation Manual

Control/Communicator Installation Manual DAS NETWORX NX-12 Control/Communicator Installation Manual General Description...2 Ordering Information...2 Option Definitions...3 Programming the LED Code Pads...5 Programming the NX-12...9 Types of Programming

More information

Series. NX-4-EUR Control Panel. Installation manual

Series. NX-4-EUR Control Panel. Installation manual g GE Security NetworX TM Series NX-4-EUR Control Panel Installation manual CONTENTS CONTENTS...2 GENERAL INFORMATION...4 ORDERING INFORMATION...4 FEATURE DEFINITIONS...5 PROGRAMMING THE NX-4 KEYPADS...12

More information

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure. Notice The material and instructions covered in this manual have been carefully checked for accuracy and are presumed to be reliable. However, Radionics, Inc. assumes no responsibility for inaccuracies

More information

CC408. Quick Reference Guide Solution 880

CC408. Quick Reference Guide Solution 880 CC408 EN Quick Reference Guide Solution 880 CC408 Quick Reference Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty Ltd ( Bosch

More information

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147) -961112-0003 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3

More information

INSTALLATION MANUAL PC25OO

INSTALLATION MANUAL PC25OO INSTALLATION MANUAL PC25OO NOTES ON UL INSTALLATION This equipment is UL listed in accordance with UL standard 1023 (Household Burglar Alarm System Units), UL standard 985 (Household Fire Warning Units)

More information

PROGRAMMING INSTRUCTIONS

PROGRAMMING INSTRUCTIONS R PROGRAMMING INSTRUCTIONS Publicly traded on NASDAQ Symbol: NSSC HARDWIRE WIRELESS GEM-P1664 CONTROL PANEL/COMMUNICATOR Programming the GEM-P1664 Control Panel with the "Classic" GEM-RP1CAe2 Keypad and

More information

INSTALLATION MANUAL & PROGRAM RECORD SHEET

INSTALLATION MANUAL & PROGRAM RECORD SHEET INSTALLATION MANUAL & PROGRAM RECORD SHEET TABLE OF DESCRIPTION CONTENTS PAGE WIRING MANUAL 2-6 MENU CHART 7 INSTALLER FUNCTIONS 8 MENU 1 SYSTEM TIMES 9 MENU 2 ZONE CONFIGURATION 10-14 MENU 3 SYSTEM OPTIONS

More information

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: -961112-0002 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3

More information

System Programming Guide

System Programming Guide & System Programming Guide Software Versions 4.4 (728ULT) and 4.1 (738ULT) Installer Code (Default - 728 Ultra: 282828; 738 Ultra: 383838) Full access to programming, except user access codes (PINs). No

More information

VISTA-100 Commercial Fire & Burglary Partitioned System

VISTA-100 Commercial Fire & Burglary Partitioned System VISTA-100 Commercial Fire & Burglary Partitioned System 4XLFN6WDUW Step-by Step Programming Procedure Single and Multiple Programming Forms System Worksheets FIRE FIRE * PULL VISTA-100PR Rev B 4/99 TABLE

More information

CC488. Quick Reference Guide Solution Ultima 880

CC488. Quick Reference Guide Solution Ultima 880 CC488 EN Quick Reference Guide Solution Ultima 880 CC488 Quick Reference Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty

More information

EVO192 v3.0 Fire and Burglary What s New

EVO192 v3.0 Fire and Burglary What s New EVO192 v3.0 Fire and Burglary What s New Compatibility: EVO192 v3.0 TM50 v1.31 K641 v2.41 Overview: CP-01 Compliancy Wiring Diagram The following sections/options have been added to the EVO192 panel. They

More information

EasyLoader. Integrated Alarm Control/Communicator. Year 2000 ready. Express Installation and Operation Manual. Edition II

EasyLoader. Integrated Alarm Control/Communicator. Year 2000 ready. Express Installation and Operation Manual. Edition II EasyLoader AV-2004, AV-2048 Integrated Alarm Control/Communicator Year 2000 ready Express Installation and Operation Manual Version 3.06 (with very slow zone) Edition II This product is subject to continual

More information

INSTALLATION MANUAL PC15OO

INSTALLATION MANUAL PC15OO INSTALLATION MANUAL PC15OO This device complies with Parts 15 and 68 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2)

More information

NetworX Series NX-6 CONTROL PANEL. Installation and Startup

NetworX Series NX-6 CONTROL PANEL. Installation and Startup NetworX Series NX-6 CONTROL PANEL Installation and Startup 25 GE Security All rights reserved. These instructions do not purport to cover all details or variations in equipment nor to provide every possible

More information

User s Information Guide R2A

User s Information Guide R2A Pi HSC505 Home Security Controller User s Information Guide R2A Page 1 of 15 of its development program. 1This document and product are copyrighted and all rights are reserved. Introduction Convention

More information

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0 User s Guide SUB-MA7240O-0001.OG.Solution40-111.doc Created: 6/05/03 Last Updated: 23/09/03 MA7240AO-0001 Version 1.0 2 Table Of Contents User List...6 Quick Reference..7 Features...7 Keypad User's Guide...8

More information

Security System. User Guide for the LED Command Center

Security System. User Guide for the LED Command Center Security System User Guide for the LED Command Center National Security Systems Inc (800)457-1999 MY SECURITY COMPANY IS: CALL BEFORE TEST: THIS SECURITY SYSTEM IS CONNECTED TO TELEPHONE NUMBER: THE SECURITY

More information

NetworX Series NX-4V2 Control Panel Installation and Startup

NetworX Series NX-4V2 Control Panel Installation and Startup NetworX Series NX-4V2 Control Panel Installation and Startup 2005 GE Security All rights reserved. These instructions do not purport to cover all details or variations in equipment nor to provide every

More information

System Introduction. 1.1 Specifications

System Introduction. 1.1 Specifications System Introduction S E C T I O N 1 1.1 Specifications Downloading Software Support PC585 uses DLS-1 v6.5 and up. Flexible Zone Configuration Four fully programmable zones; system expandable to eight zones

More information

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE... TABLE OF CONTENTS...Glossary of terms...2...code Pad Diagram...3 Understanding the Code Pad lights...4 Code Pad tones...5 Fully arming the system On MODE...6 Fully arming the system - Quick Arm MODE...6

More information

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions WIC-16Z4P WIC-5Z2P User Instructions Page : 2/14 INDEX # Function Page 1 Add a New User Code 11 2 Arm or Disarm All Areas or Disarm Selected Areas (Partitioned System) 8 3 Arming the System (Away Mode)

More information

RE6100 Series Helix Security and Automation Platform

RE6100 Series Helix Security and Automation Platform CONFIGURATION Resolution Compatibles RE6100 Series Helix Security and Automation Platform C G UI D E Configuration Settings Table 1 - Panel Settings Table 2 - Zone Settings Table 3 - Device Settings Table

More information

INSTALLATION MANUAL PC56O. Version 1.OA

INSTALLATION MANUAL PC56O. Version 1.OA INSTALLATION MANUAL PC56O Version 1.OA TABLE OF CONTENTS INTRODUCTION 3 Features... 3 Specifications... 3 INSTALLATION 4 Mounting the Control Panel... 4 Mounting the Keypad... 4 Wiring... 5 Burglary Zone

More information

2000 Series. Program Entry Guide. Control Panels

2000 Series. Program Entry Guide. Control Panels 2000 Series EN Program Entry Guide Control Panels 2000 Series Program Entry Guide About This Manual EN 2 About This Manual This guide describes the programming parameters available to the 2000 Series Control

More information

AXI LED USER MANUAL (REV. 1.0)

AXI LED USER MANUAL (REV. 1.0) Security & Home Automation System AXI LED USER MANUAL (REV. 1.0) CONTENTS PREFACE FEATURES LED KEYPAD OUTLOOK 1.0 LIGHT INDICATION 1 2 4 6 CHAPTER 1: ALARM SYSTEM CONTROL 1.0 USING LED KEYPAD 1.0.1 ARMING

More information

Solution 862 Installation Manual ISSUE 1.30

Solution 862 Installation Manual ISSUE 1.30 Solution 862 Installation Manual ISSUE 1.30 MA406I This page has been included for you to cut out and insert into the spine of the folder Solution 862 Installation Manual ISSUE 1.30 (61-2) 9672 1233 Solution

More information

Installation Manual Premier 412/816/832. Issue 10

Installation Manual Premier 412/816/832. Issue 10 Installation Manual Premier // Issue 0 Premier // Installation Manual 5. Operating the System Introduction Before attempting to operate the alarm system ensure you have familiarised yourself with all the

More information

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master) User Codes (1-6 digits) Access Levels Access Levels + Time Control User 1 (Master) 1 1 2 3 25 49 73 0 User 2 2 26 50 74 0 User 3 3 27 51 75 0 User 4 4 28 52 76 0 User 5 5 29 53 77 0 User 6 6 30 54 78 0

More information

ITI Caretaker Basic Commands

ITI Caretaker Basic Commands ITI Caretaker Basic Commands System can be accessed by telephone or wireless keypad Zones - Up to 30 Wireless or 24 Hardwired Battery - 12 volt 1.9 amp rechargeable Lead-Acid inside main panel, only found

More information

PROGRAMMING INSTRUCTIONS

PROGRAMMING INSTRUCTIONS R PROGRAMMING INSTRUCTIONS Publicly traded on NASDAQ Symbol: NSSC HARDWIRE WIRELESS GEM-P9600 CONTROL PANEL/COMMUNICATOR Programming the GEM-P9600 Control Panel with the "Classic" GEM-RP1CAe2 Keypad and

More information

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4 Programming Guide We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com

More information

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00 INHEP DIGITAL IDS S E C U R I T Y IDS816 User Manual MANUAL NO. 700-283-01 B ISSUED DEC 2004 VERSION 2.00 Contents 1. Introduction to the IDS816... 4 2. Understanding the Keypad Indicators... 4 3. Programmable

More information

PROGRAMMING PROCEDURES (Table 3)

PROGRAMMING PROCEDURES (Table 3) CONDOPLEX 2600/2600A/2700 Suite Panel User Manual Document Version 8.4 Oct 19, 1998 Condoplex 1998 PROGRAMMING PROCEDURES (Table 3) FUNCTION PRESS KEYPAD DISPLAY Delete user code or duress code. 0 (hold)

More information

NX-148 LCD CODE PAD TABLE OF CONTENTS

NX-148 LCD CODE PAD TABLE OF CONTENTS NX-148 LCD CODE PAD TABLE OF CONTENTS Glossary Of Terms... 4 Understanding The Lights... 5 Code Pad Functions Arming In The ON Mode... 6 Making The System Ready To Arm... 7 Using Quick Arm... 7 Arming

More information

Condominium Security Management System

Condominium Security Management System User Access Codes The CONDOPLEX series panels can be programmed with nine (9) different user codes and one (1) duress code. User codes are normally used for arming and disarming the panel. The duress code

More information

Security System. User s Guide for the Text Command Center

Security System. User s Guide for the Text Command Center User s Guide for the Text Command Center MY ALARM COMPANY IS: CALL BEFORE TEST: THIS SECURITY SYSTEM IS CONNECTED TO TELEPHONE NUMBER: THE SECURITY CONTROL PANEL IS CONNECTED TO THE PHONE JACK LOCATED:

More information

Installation Instructions

Installation Instructions g 466-2339A October 2009 2009 GE Security, Inc. Introduction This is the GE. Installations should only be done by trained professionals. Use this document to install the system with default settings that

More information

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup NetworX Series NX-8 Commercial Fire Panel Installation and Startup 2004 GE Security All rights reserved. Printed in the United States of America. These instructions do not purport to cover all details

More information

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160 All-In-One Wireless Security System V3.2 Programming Guide Model # MG6130 / MG6160 We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com

More information

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1 1.1 PC5015 Specifications System Introduction S E C T I O N 1 Flexible Zone Configuration: 8 Fully Programmable Zones 38 Access Codes: 32 User, 1 System Master, 2 Partition Master, 2 Duress and 1 maintenance

More information

OPERATING GUIDE FOR YOUR RP1054D KEYPAD

OPERATING GUIDE FOR YOUR RP1054D KEYPAD OPERATING GUIDE FOR YOUR RP1054D KEYPAD Napco 1992 DESIGN PATS. PENDING Technical Manuals Online! - http://www.tech-man.com CONGRATULATIONS!...on your purchase of a NAPCO Magnum Alert security system.

More information

Solution 6+6 Wireless On/Off Installation Manual ISSUE 1.20

Solution 6+6 Wireless On/Off Installation Manual ISSUE 1.20 Solution 6+6 Wireless On/Off Installation Manual ISSUE 1.20 MA670I This page has been included for you to cut out and insert into the spine of the folder Solution 6+6 Wireless On/Off Installation Manual

More information

DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel

DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel CAUTION: It is advised that an experienced alarm installer programs the panel as further programming may be required

More information

ABOUT THE CONSOLES A CONSOLES STYLE CONSOLES (SHOWN WITH KEYPAD COVER REMOVED) 5137AD ALPHA CONSOLE 6139 ALPHA CONSOLE 4127 4137AD 612716120 6137 FIXED-WORD CONSOLES FIXED-WORD CONSOLES FUNCTIONS OF THE

More information

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging 1.1 Specifications System Introduction S E C T I O N 1 Control Panel Specifications Flexible Zone Configuration: 8 Fully Programmable Zones 38 Access Codes: 32 User, 1 System Master, 2 Partition Master,

More information

System Introduction. 1.1 Specifications S E C T I O N 1

System Introduction. 1.1 Specifications S E C T I O N 1 System Introduction S E C T I O N 1 1.1 Specifications Control Panel Specifications Flexible Zone Configuration: 8 Fully Programmable Zones 37 Access Codes: 32 User, 1 System Master, 2 Partition Master

More information

EasyLoader AV-2004, AV Integrated Alarm Control/Communicator. Year 2000 ready. Express Installation and Operation Manual. Version 2.

EasyLoader AV-2004, AV Integrated Alarm Control/Communicator. Year 2000 ready. Express Installation and Operation Manual. Version 2. EasyLoader AV-2004, AV-2048 Integrated Alarm Control/Communicator Year 2000 ready Express Installation and Operation Manual Version 2.17 Edition II This product is subject to continual enhancement and

More information

Quick Programmer s Manual

Quick Programmer s Manual Version 2.604 (31/03/05) p1 Quick Programmer s Manual 2005. Inner Range Pty. Ltd. Part Number: 630048V2 p2 Version 2.604 (31/03/05) TABLE OF CONTENTS. 1. PROGRAMMING FLOWCHART. The following flowchart

More information

CHEAT SHEET: SPECTRA V2.1

CHEAT SHEET: SPECTRA V2.1 CHEAT SHEET: SPECTRA V2.1 Zone mapping Device connected To which input? NO ATZ WITH ATZ CONTROL PANEL INPUT 1= ZONE 1 ZONE 1 & 6 INPUT 2= ZONE 2 ZONE 2 & 7 INPUT 3= ZONE 3 ZONE 3 & 8 INPUT 4= ZONE 4 ZONE

More information

0$(6752 0$(6752. Programming Guide. 6 and 10 Zone Alarm Control Panel ,1752'8&7,21 +(;$ 352*5$00,1* 675($0/,1(' 6(&7,21 352*5$00,1* FIGURE 1 FIGURE 2

0$(6752 0$(6752. Programming Guide. 6 and 10 Zone Alarm Control Panel ,1752'8&7,21 +(;$ 352*5$00,1* 675($0/,1(' 6(&7,21 352*5$00,1* FIGURE 1 FIGURE 2 0$(6752 0$(6752 6 and 10 Zone Alarm Control Panel Programming Guide,1752'8&7,21 The Maestro-600 and Maestro-1000 alarm control panels enable reduced number of programming steps. End-users can access most

More information

OPERATING GUIDE for your GEM-RP1CAe2 KEYPAD

OPERATING GUIDE for your GEM-RP1CAe2 KEYPAD OPERATING GUIDE for your GEM-RP1CAe2 KEYPAD GEMINI SYSTEM READY 09/01/05 12:09 AM ARMED STATUS A 1 2 3 B 4 5 6 J C 7 8 9 0 NEXT / YES E PRIOR / NO F AREA G COMPUTERIZED SECURITY SYSTEM Simplified instructions

More information

NetworX Series NX-1500E LED Keypad

NetworX Series NX-1500E LED Keypad NetworX Series NX-1500E LED Keypad User Manual SECURITY SYSTEM NOTES Installing/Service Company For Service Call Central Station Duress Code FUNCTION CODES Function Code Controls Function This system

More information

Control Panel ICP-SOL2-P/ICP-SOL3-P. en User's Guide

Control Panel ICP-SOL2-P/ICP-SOL3-P. en User's Guide Control Panel ICP-SOL2-P/ICP-SOL3-P en User's Guide Control Panel Table of Contents en 3 Table of contents 1 Introduction 5 2 Specifications 6 3 Codepad Introduction 7 3.1 Codepad 7 3.2 Quick Codepad

More information

SECURITY SYSTEM NOTES

SECURITY SYSTEM NOTES SECURITY SYSTEM NOTES Installing/Service Company For Service Call Central Station Duress Code FUNCTION CODES Function Code Controls Function EMERGENCY ACTIVATION KEYS (check if enabled) Fire Auxiliary

More information

Tomorrow s technology for today s security needs.

Tomorrow s technology for today s security needs. Tomorrow s technology for today s security needs. The Security Command Keypad Welcome Congratulations on your decision to purchase a Security Command system. The new Security Command keypad, from one of

More information

Solution 6+6 Wireless - AE Installation Manual ISSUE 1.10

Solution 6+6 Wireless - AE Installation Manual ISSUE 1.10 Solution 6+6 Wireless - AE Installation Manual ISSUE 1.10 MA660I Solution 6+6 This page has been included for you to cut out and insert into the spine of the folder Wireless AE Installation Manual ISSUE

More information

Contents. Glossary

Contents. Glossary Contents Glossary ------------------------------------------------------------------------------------------------------ 6 1. Introduction to the IDS 1632 -------------------------------------------------------------

More information

ADEMCO VISTA-10P ADEMCO VISTA-10PSIA Security Systems

ADEMCO VISTA-10P ADEMCO VISTA-10PSIA Security Systems ADEMCO VISTA-10P ADEMCO VISTA-10PSIA Security Systems Programming Guide K0735PRV5 3/15 Rev A COMPATIBILITY: This Programming Guide is intended for VISTA-10P/VISTA-10PSIA controls with firmware revision

More information

NETWORX TM. User manual NX-4

NETWORX TM. User manual NX-4 NETWORX TM User manual NX-4 POWER Light is on when AC power is present; flashes to indicate a low battery condition. ARMED Light is on when armed; off when disarmed; flashes to indicate a previous alarm.

More information

VISTA-50P VISTA-50PUL

VISTA-50P VISTA-50PUL Security System User's Manual VISTA-50P VISTA-50PUL N5943-6V1 Rev B 4/99 TABLE OF CONTENTS SYSTEM OVERVIEW...4 General...4 A Partitioned System...4 Zones...4 Fire Protection...5 Burglary Protection...5

More information

Programming Worksheets

Programming Worksheets WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully

More information

Training Manual Multi-Language with Wireless

Training Manual Multi-Language with Wireless Training Manual Multi-Language with Wireless Installer Training Firmware Version 2.3 X16 Stock Code: 860-1-473-X16 X64 Stock Code: 860-1-864-XS 2 Contents IDS X Series Training V2.3 Contents Contents 3

More information

NetworX NX-8V2. LED Keypad User Manual

NetworX NX-8V2. LED Keypad User Manual NetworX NX-8V2 LED Keypad User Manual POWER Light is on when AC power is present; flashes to indicate a low battery condition. ARMED Light is on when armed; off when disarmed; flashes to indicate a previous

More information

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00 INHEP DIGITAL IDS S E C U R I T Y IDS816 User Manual MANUAL NO. 700-283-01C ISSUED APRIL 2005 VERSION 2.00 Contents 1. Introduction to the IDS816... 4 2. Understanding the Keypad Indicators... 4 3. Programmable

More information

R E G E N C Y Model 2615 Control/Communicator. Installation Manual. Part Number , Rev. A Initial Release Date: March 1995 Revised August 1998

R E G E N C Y Model 2615 Control/Communicator. Installation Manual. Part Number , Rev. A Initial Release Date: March 1995 Revised August 1998 R E G E N C Y Model 2615 Control/Communicator Installation Manual Part Number 150863, Rev. A Initial Release Date: March 1995 Revised August 1998 Interactive Technologies, Inc. TE CHNO LO G IES Security

More information

ABORT Light flashes during an abort delay time; is on during or after an alarm report to the central station. EMERGENCY ACTIVATION KEYS

ABORT Light flashes during an abort delay time; is on during or after an alarm report to the central station. EMERGENCY ACTIVATION KEYS POWER Light is on when AC power is present; flashes to indicate a low battery condition. CHIME Light is on when the chime feature is active. ABORT Light flashes during an abort delay time; is on during

More information

HILLS Series LED Code Pad User Manual

HILLS Series LED Code Pad User Manual HILLS Series LED Code Pad User Manual Not all features may be available on your system Check with your installer to find out which features are programmed Page 2 TABLE OF CONTENTS Code Pad Diagrams...2

More information

4-PGM Expansion Module

4-PGM Expansion Module 4-PGM Expansion Module APR3-PGM4 = Default setting SECTION [001] : General Options SECTION [002] : PGM Options Option OFF ON Option OFF ON [1] Future Use N/A N/A [1] PGM1 Deactivation After Deactivation

More information

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

IDS S E C U R I T Y IDS816.  User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00 INHEP DIGITAL IDS S E C U R I T Y IDS816 User Manual MANUAL NO. 700-283-02A ISSUED November 2004 VERSION 1.00 Contents 1. Introduction to the IDS816... 4 2. Understanding the Keypad Indicators... 4 3.

More information

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide MG6250 2-Partition 64-Zone Wireless Console with GPRS/GSM Version.6 Section Programming Guide Things You Need to Know About this Programming Guide The MG6250 All-in-one Wireless Console can be programmed

More information

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE D (OPERATION) INITIATE A DYNAMIC BATTERY TEST The system tests the back-up battery once every 24 hours. The owner can initiate a dynamic battery test at any time with the following codes while the system

More information

FBII Security System. Programming Guide. Version 2.X. N9967PRV3 4/04 Rev. A

FBII Security System. Programming Guide. Version 2.X. N9967PRV3 4/04 Rev. A FBII Security System OMNI -624 Version 2.X Programming Guide N9967PRV3 4/04 Rev. A CONTENTS INSTALLER MODE 1 COMMANDS... 3 INSTALLER MODE 1 (PROGRAMMING MODE)... 4 SUBMODE 1: SYSTEM OPTIONS... 4 Telephone

More information

Digiplex LED Keypads User s Manual

Digiplex LED Keypads User s Manual KLEDEU03.fm Page -1 Friday, May 4, 2001 11:25 AM Digiplex LED Keypads User s Manual KLEDEU03.fm Page 0 Friday, May 4, 2001 11:25 AM KLEDEU03.fm Page 1 Friday, May 4, 2001 11:25 AM TABLE OF CONTENTS 1.0

More information

8-zone Expansion Module

8-zone Expansion Module 8-zone Expansion Module APR3-ZX8 SECTION [001] : General Options Option OFF ON [1] Tamper Recognition ON = Input 8 (Z8) becomes tamper input = Default setting Disabled Enabled [2] PGM Deactivation After

More information