FBII Security System. Programming Guide. Version 2.X. N9967PRV3 4/04 Rev. A

Size: px
Start display at page:

Download "FBII Security System. Programming Guide. Version 2.X. N9967PRV3 4/04 Rev. A"

Transcription

1 FBII Security System OMNI -624 Version 2.X Programming Guide N9967PRV3 4/04 Rev. A

2 CONTENTS INSTALLER MODE 1 COMMANDS... 3 INSTALLER MODE 1 (PROGRAMMING MODE)... 4 SUBMODE 1: SYSTEM OPTIONS... 4 Telephone and Pager Numbers... 4 Account Numbers... 4 Reporting and System Options... 4 CS Format/Rcvr Type... 4 Reporting Options... 5 System Options... 5 Other System Options... 5 Arming Options... 5 Sound Options... 5 Display Options... 5 Log Options... 5 Bells/AC Delay/Ring Cnt... 5 Exit Delay/Dialer Delay... 5 Delay Delay C/S Test Time... 5 Pager Options... 5 Keypad Tamper... 5 RF Jam... 5 Soft Keys for 1 & 3/7 & Soft Keys for & #... 5 Auto Arm Enables... 5 Auto Arm Time P1 (User)... 5 Auto Arm Time P2 (User)... 5 Trigger/Relay Types... 7 Keypad Mapping... 7 Keyfob Button Functions... 8 Relay/Trigger Time for Momentary Outputs... 8 Open/Close CS Report Disables... 8 SUBMODE 2: ZONE PROGRAMMING AND REPORT CODES... 9 Zone Report Codes System Report Codes Duress/AC Loss Bypass/Trouble Keypad & #/Bat Loss Walk Test Open/Close & RF Jam Event Log Keypad 7 & 9/1 & RF Supervision Keypad Tamper/CS Test Arm Disable/Clock Set False Alarm Up-About/Clock Fail Bell Supervision Keypad Tamper st RF Zone/1st Dbld Zone Crossed Zones SUBMODE 3: WIRELESS TRANSMITTER PROGRAMMING Wireless Zone Configuration/Serial Number Keyfob Configuration/Serial Number SUBMODE 4: DESCRIPTOR PROGRAMMING Zone Descriptors for Zones Partition Descriptors

3 To INSTALLER MODE 1 COMMANDS Press Enter Installer Mode 1 [CODE] [ ] (installer s code) [1] (select submode number 1 4) Sub Modes: System Options Zone Prog./Report Codes Wireless Programming Descriptor Programming Enter data Go to next location in question [#] Go to next question (enter installer mode 1) [1] (enter installer mode 1) [2] (enter installer mode 1) [3] (enter installer mode 1) [4] appropriate key then [#] to accept entry [INSTANT] or [ ] (2-digit question no.) Go to another submode [ ] [BYPASS] (select desired submode number 1 4) Exit Program Mode [STAY] N9967PRV3 4/04 Rev. A

4 INSTALLER MODE 1 (Programming Mode) SUBMODE 1: SYSTEM OPTIONS Enter installer mode 1, then select submode 1. The display shows the following: Q#01 M1 Edit L:01 DATA: 234A System Default values are shown inside brackets. NOTE: When you enter Submode 1, question 01 is automatically displayed. To change or review the Installer Code (question 00), enter [ ] + [0] + [0]. The Installer Code will be displayed. Q 00 Installer Code N/U N/U [246800AA] QUESTIONS 01 05: TELEPHONE and PAGER NUMBERS Enter the appropriate telephone numbers in Questions 1 5. Questions 1 3 support up to 20-digit numbers. Questions 4 and 5 supports up to 16-digit numbers. Q 01 PRIMARY CS NUMBER [234A ] Q 02 SECONDARY CS No. [AAA ] Q 03 CALLBACK NUMBER [AAA ] Q 04 PARTITION 1 PAGER NUMBER [AAA ] Q 05 PARTITION 2 PAGER NUMBER [AAA ] QUESTIONS 06 09: ACCOUNT NUMBERS Enter the appropriate account numbers in questions 06 through digit formats will ignore last digit. Q 06 PART. 1 PRIMARY [1234] Q 08 PART. 2 PRIMARY [1222] Q 07 PART. 1 SECONDARY [2234] Q 09 PART. 2 SECONDARY [2222] QUESTIONS 10 31: REPORTING and SYSTEM OPTIONS For detailed explanations, refer to the programming tables in the Installation Instructions when making the following entries. You can also calculate the value of an entry by adding the binary values of the desired options in each location. The values are, from top to bottom, 1, 2, 4, 8. Enter 0 if none of the options are desired. Enter A F for values of respectively. For Questions with locations containing more than 4 options, charts listing them are provided (these options are indicated with an asterisk). Q 10 CS FORMAT/RCVR TYPE [E0E0] L1 L2 L3 L4 CS1 CS2 Format Rcvr Format Rcvr (see chart below for values to enter) L1/L3 CS REPORTING TRANS L2/L4 FORMAT PULSE SPEED HANDSHAKE FORMAT TYPE 10 PPS 20 PPS 40 PPS 1400 HZ 2300 HZ Parity TYPICAL CS RECEIVER 0 3x1 Standard PULSE 0 FBII, ADEMCO, SILENT KNIGHT 1 4x1 Standard PULSE 1 FBII, ADEMCO, RADIONICS 2 3x1 Extended PULSE 2 FBII 3 4x1 Extended PULSE 4 FBII, SILENT KNIGHT 4 3x1 Partial Extended PULSE 5 FBII, RADIONICS 5 4x1 Partial Extended PULSE 6 FBII, RADIONICS 6 3x2 PULSE 8 FBII 7 4x2 PULSE 9 FBII, ADEMCO 8 FBII Superfast DTMF A FBII, ADEMCO 9 ADEMCO 4x1 Express * DTMF C FBII, ADEMCO A ADEMCO 4x2 Express * DTMF D FBII, ADEMCO E ADEMCO Contact ID * DTMF E FBII, ADEMCO N9967PRV3 4/04 Rev. A

5 Q 11 REPORTING OPTIONS L1* L2 L3 L4 [07FF] Dial Type Restore Dial attmpts Restores report option supervsn (1-15) AC sends rstr report option tamper Low Bat sends rstr rpt stay byp RF low bat zone sends rstr FTO/LTC rstr follows loop Dial type report option 00=backup, 01=dual, 10=split, 11=disabled Q 12 SYSTEM OPTIONS UL: L4 must be 3. [0020] L1 L2 L3 L4* no bell/dial n/a euro pulse test time interval fast zone 5/6 Relay enbl. tone/pulse dbl bal n/a user 6/4 digit RF enable bell sprvs. Q 13 OTHER SYSTEM OPTIONS UL: L1 door strike option not evaluated by UL. [48C2] L1 L2 L3* L4 user online key tamp. pager attmpt swinger count duress (31, 32) tamp reset pager attmpt (0-3) no code dr strike crystal RTC sprv time bat test 4/1s door (20-30) tone burst on sprv time delay if stay Q 14 ARMING OPTIONS UL: Do not use L2 bypass error, [818F] L3 exit extends, L4 quick exit L1 L2 L3 L4 stay=stay arm w/fault disbl arm P1 quick arm fob autostay byp/exit err disbl arm P2 force arm inst=away arm no dwnld n/a quick exit inst enbl no arm lo bat exit ext. quick bypass Q 15 SOUND OPTIONS UL: L4 must be F. L1 L2 L3 L4 fob ding only thresh sndr phone fail en. RF sprv bell ding enbl thresh bell phn fail sndr RF lo bat disarm ding enbl CS test ring phn fail bell sys lo bat fast ding invert bell bell on cancel AC loss Q 16 DISPLAY OPTIONS [000F] UL: Do not enable L1 no AC loss (must display AC loss) [1130] L1 L2 L3 L4 armed byp time w/o code clock 24hr Language fault on entry daylight save day/mo (0=Eng, 1=Ital,) AC loss LED extinguish show time 2=Span, 3= French Byp limit 3 FOB LB clock fail 4=Dutch, 5= Port) Q 17 LOG OPTIONS _ x _ L1 L2 L3 [EFF0] By Part/all open RF bat En #53 log close RF sprv log zone alarm sys events tamper log zone trbl key events bypass Q 18 BELLS/AC DELAY/RING CNT UL: L1 and L2 must be 2. L3 must be F. [5F18] L1* L2* L3* L4 Burg bell Fire bell AC dial ring timeout timeout delay count (times 3min) (times 3 min) (times 15 min) (0-15, 0=disable) (0=random) Q 19 EXIT DELAY/DIALER DELAY L1 L2 L3 L4 [CC00] Exit Exit n/a abort dial time P1 time P2 delay time* (Exit time = value times 10 for number of seconds; for dial delay, see dialer delay chart on next page for Question 19) UL: L1, L2 must be 5. L4 dial delay must be 0. Q 20 ENTRY DELAY 1 _x_ _x_ L1 L2 [5500] time 1 P1 time 1 P2 (For values, see entry delay charts on next page for Questions 20 and 21) UL: Q20/Q21 entry delay must be 6 (45 seconds) Q 21 ENTRY DELAY 2 _x_ _x_ L1 L2 [3300] time 2 P1 time 2 P2 (For values, see entry delay charts on next page for Questions 20 and 21) Q 22 C/S TEST TIME (0300) Hours Minutes (00-23) (00-59) Q 23 PAGER OPTIONS _x_ L1 (part. 1) L2 (part. 2) L3 L4 zone alarm zone alarm n/a enbl users page P1 zone trbl zone trbl enbl users page P2 open open n/a close close #58 follow-me Q 24 KEYPAD TAMP, ARM & RF JAM _x_ L1 L2 L3 L4 n/a keypad tamp no arm if jam jam detect enable tamp sound no arm super jam Euro/US tamp bell no AC 2X jam sounder jam bell Q 25 NOT USED Q 26 SOFT KEYS FOR 1 & 3/7 & 9 1 & 3 Keys 7 & 9 Keys L1* L2 L3* L4 sound opt arm away sound opt arm away (chart below) arm stay (chart below) arm stay relay opt page trbl relay opt page trbl (chart below) (chart below) Q 27 SOFT KEYS FOR & # _x_ _x_ L1* L2 & # Keys not used sound opt arm away [2000] (chart below) arm stay relay opt page trbl (chart below) Q 28 AUTO ARM ENABLES _x_ UL: L1, L2 must be 0. L1 L2 L3 L4 auto arm P1 auto arm P2 n/a up/about P1 arm warn P1 arm warn P2 up/about P2 instant arm P1 instant arm P2 stay arm P1 stay arm P2 Q 29 AUTO ARM TIME P1 (0000) Hours Minutes UL: Must be disabled. (00-23) (00-59) Q 30 AUTO ARM TIME P2 (0000) Hours Minutes UL: Must be disabled. (00-23) (00-59) Q 31 NOT USED For Q 26 & Q 27, L1/L3: Sounder Options Relay Options L1/L3 Burg. No Mom. Mom. Silent Keypad Bell Temporal Relay Seconds Minutes Toggle A B C D E F * Refer to the charts on the next page (except Questions 26 & 27; see chart above, right). 5

6 Use the following charts when making entries for Questions 11, 12, 13, 19, 20, 21. Q 11, L1: Enter the L1 digit for the desired reporting options from the table below. L1 Report Type Report First to open Backup Dual Split Disabled Stay Bypass Last to close A C D E Q 12, L4: Enter the L4 digit for the desired options from the table below. L4 Test Interval by Time Disable Every Hour 1 Day 7 Days 27 Days 60 Days 90 Days 180 Days Test Interval Reset by Event 9 A B C D E Q 13, L3: Enter the L3 digit from the table below. L3 Pager Attempts Supervision Time (Hrs) 20/1* Disabled Disabled Disabled 9 A B C Disabled D E F *20 Minutes when disarmed 1 Hour when armed Q19, L4: Enter the L4 digit for the desired dialer delay from the following table. L4 Dialer Delay Seconds A 120 B 150 C 180 D 210 E 240 F 255 Q 20 and 21, L1 L2: These questions define entry delays 1 and 2. L1-L2 Delay (Seconds) L1-L2 Delay (Seconds) A B C D E F 240 6

7 QUESTIONS 32 43: TRIGGER/RELAY TYPES For Questions 32 43, make entries from the table in the right column. Note: Triggers 3 and 4 are used for the XL4705 relay module if selected in Question 12, L2 Q 32 RELAY 1 and 2 TYPES Relay 1 Relay 2 Q 33 RELAY 3 and 4 TYPES Relay 3 Relay 4 Q 34 RELAY 5 and 6 TYPES Relay 5 Relay 6 Q 35 RELAY 7 and 8 TYPES Relay 7 Relay 8 Q 36 RELAY 9 and 10 TYPES Relay 9 Relay 10 Q 37 RELAY 11 and 12 TYPES Relay 11 Relay 12 Q 38 RELAY 13 and 14 TYPES Relay 13 Relay 14 Q 39 RELAY 15 and 16 TYPES Relay 15 Relay 16 Q 40 RELAY 17 and 18 TYPES Relay 17 Relay 18 Q 41 RELAY 19 and 20 TYPES Relay 19 Relay 20 Q 42 TRIGGER 1 and 2 TYPES Trigger 1 Trigger 2 Q 43 TRIGGER 3 and 4 TYPES Trigger 3 Trigger 4 P1 P2 Relay Type Disabled Burg Bell no Bell Test Fire Bell no Bell Test Partition Armed Partition Ready In Delay In Exit Delay Armed Instant Armed Stay Sounder on/pulsing 0A 4A Chime 0B n/a Line Seize (System) 0C n/a Phone Fail (System) 0D n/a AC Loss (System) 0E n/a Low Battery (System) 0F 4F 24 Hr Zone in Trouble Hr Zone Alarmed Instant Zone Faulted Delay Zone Faulted Interior Zone Faulted Zone Tamper RF Low Battery RF Supervision 17 n/a Comm. Fail (System) Key Tamper, mom. Sec Duress Code, mom. Sec 1A 5A Bell Strobe - Internal, No dings 1B 5B Bell Strobe - External, with dings 1C 5C Trigger Zone, mom Minutes 1D 5D Trigger Zone, mom. Seconds 1E 5E Door Strike, mom. Seconds 1F 5F Shock Reset (*) Seconds CS Test Momentary Secs Alarm/Restore by partition 22 n/a 2-way voice, on after seize rel Momentary by Seconds (fob,soft) Momentary by Minutes (fob,soft) Toggle (Keyfob, softkeys) 26 n/a Follows Zn Loop, Trig=Zn n/a Follows Zn Loop, Trig=Zn n/a Zone alarm - zones zones n/a Zone alarm - zones zones A n/a Zone alarm restore - zones B n/a Zone alarm restore - zones C n/a Sys Bell, Internal (no Dings) 2D n/a Sys Bell, External (with Dings) 2E 6E RF Jam 2F n/a Keypad Tamper Hour Silent Zone QUESTIONS KEYPAD MAPPING The system automatically reads keypad addresses during initial installation. Questions are shown for reference and/or programming after initial installation. NOTE: LCD = OMNI-LCD, OMNI-LCD-US, or XK7LC; Non-LCD = OMNI-KP or OMNI-KP-US Q 44 KEYPAD MAP for PART. 1 L1 L2 L3 L4 [8000] LCD 5 LCD 1 non-lcd 5 non-lcd 1 LCD 6 LCD 2 non-lcd 6 non-lcd 2 LCD 7 LCD 3 non-lcd 7 non-lcd 3 LCD 8 LCD 4 non-lcd 8 non-lcd 4 Q NOT USED Q 45 KEYPAD MAP for PART. 2 L1 L2 L3 L4 LCD 5 LCD 1 non-lcd 5 non-lcd 1 LCD 6 LCD 2 non-lcd 6 non-lcd 2 LCD 7 LCD 3 non-lcd 7 non-lcd 3 LCD 8 LCD 4 non-lcd 8 non-lcd 4 N9967PRV3 4/04 Rev. A

8 QUESTIONS KEYFOB BUTTON FUNCTIONS and USERS For Odd Numbered Questions 49-63, make entries from the following table: L1-L4 Keyfob Function L1-L4 Keyfob Function 0 Disabled 6 Keypad fire 1 Disarm 7 keypad panic 2 Arm away 8 keypad aux. 3 Arm stay 9 relay type 23 (mom. seconds) 4 Arm instant A relay type 24 (mom. minutes) 5 Arm stay/instant B relay type 25 (toggle) For Even numbered Questions 50-64, enter primary arming partition 1or 2 and 2-digit user no.. Make L2 entry from the following table: L2 Arming Partition UL: Keyfobs not evaluated for UL installations. Q 49 KEYFOB 1 FUNCTIONS [4123] But 1 But 2 But 3 But 4 Q 50 KEYFOB 1 USER _x_ [0001] arm User no. part Q 51 KEYFOB 2 FUNCTIONS [4123] But 1 But 2 But 3 But 4 Q 52 KEYFOB 2 USER _x_ [0001] arm User no. part Q 53 KEYFOB 3 FUNCTIONS [4123] But 1 But 2 But 3 But 4 Q 54 KEYFOB 3 USER _x_ [0001] arm User no. part Q 55 KEYFOB 4 FUNCTIONS [4123] But 1 But 2 But 3 But 4 Q 56 KEYFOB 4 USER _x_ [0001] arm User no. part Q 57 KEYFOB 5 FUNCTIONS [4123] But 1 But 2 But 3 But 4 Q 58 KEYFOB 5 USER _x_ [0001] arm User no. part Q 59 KEYFOB 6 FUNCTIONS [4123] But 1 But 2 But 3 But 4 Q 60 KEYFOB 6 USER _x_ [0001] arm User no. part Q 61 KEYFOB 7 FUNCTIONS [4123] But 1 But 2 But 3 But 4 Q 62 KEYFOB 7 USER _x_ [0001] arm User no. part Q 63 KEYFOB 8 FUNCTIONS [4123] But 1 But 2 But 3 But 4 Q 64 KEYFOB 8 USER _x_ [0001] arm User no. part QUESTIONS 65/66 RELAY/TRIGGER TIME for MOMENTARY OUTPUTS Enter 0-F (0-15) for each location in questions 65 and 66 (P1-P2 = partition 1 to partition 2 respectively). Q 65 RELAY/TRIG TIME MIN. _x_ _x_ Q 66 RELAY/TRIG TIME SECS. P1 P2 P1 P2 _x_ _x_ QUESTIONS OPEN/CLOSE CENTRAL STATION REPORT DISABLES Enter 0-F (0-15) for each location in questions Q 67 OP/CL DISABLE Users 1-16 Q 68 OP/CL DISABLE Users

9 SUBMODE 2: ZONE PROGRAMMING AND REPORT CODES While in Installer Mode 1, press [ ] + [BYPASS], then select submode [2]. The display shows the following: Q#01 M2 Edit L:01 DATA: 2000 Zn/Cde Use the following tables when programming zones. L1: Select entry from the following table: L1 Zone Type Controlled Types L1 Zone Type 24 Hour Types 0 Disabled 8 Keyswitch 1 Instant 9 Trigger Zone 2 Delay A Trouble Zone 3 Delay 2 B Alarm Zone 4 Interior C Alarm/Trouble 5 Day Zone E Fire No Verification L2: Select entry from the following table: F Fire With Verification L2 Partition Hardwire Loop Type Wireless Supervision 1 2 EOL N/C N/O Supervise Tamper L3: 0 = none; 1 = silent zone; 2 = swinger suppression zone; 3 = both silent zone and swinger suppression zone. UL: L3 swinger suppression must be disabled. L4: Select entry from the following table: L4 Stay Auto-Stay Chime Dial Delay A B C D E F Q 01 ZONE 1 (type/attributes) [2000] Q 02 ZONE 2 (type/attributes) [4000] Q 03 ZONE 3 (type/attributes) [1000] Q 04 ZONE 4 (type/attributes) [1000] Q 05 ZONE 5 (type/attributes) [1000] Q 06 ZONE 6 (type/attributes) [1000] Q 07 ZONE 7 (type/attributes) Q 08 ZONE 8 (type/attributes) Q 09 ZONE 9 (type/attributes) Q 10 ZONE 10 (type/attributes) Q 11 ZONE 11 (type/attributes) Q 12 ZONE 12 (type/attributes) Q 13 ZONE 13 (type/attributes) Q 14 ZONE 14 (type/attributes) Q 15 ZONE 15 (type/attributes) Q 16 ZONE 16 (type/attributes) Q 17 ZONE 17 (type/attributes) Q 18 ZONE 18 (type/attributes) Q 19 ZONE 18 (type/attributes) Q 20 ZONE 18 (type/attributes) Q 21 ZONE 21 (type/attributes) Q 22 ZONE 22 (type/attributes) Q 23 ZONE 23 (type/attributes) Q 24 ZONE 24 (type/attributes) 9

10 QUESTIONS 25 36: ZONE REPORT CODES Q 25 ZONE 1/2 REPORT Q 31 ZONE 13/14 REPORT [6142] 1 st 2 nd 1 st 2 nd [3030] 1 st 2 nd 1 st 2 nd zone 1 zone 2 zone 13 zone 14 Q 26 ZONE 3/4 REPORT Q 32 ZONE 15/16 REPORT [3334] 1 st 2 nd 1 st 2 nd [3030] 1 st 2 nd 1 st 2 nd zone 3 zone 4 zone 15 zone 16 Q 27 ZONE 5/6 REPORT Q 33 ZONE 17/18 REPORT [3536] 1 st 2 nd 1 st 2 nd [3030] 1 st 2 nd 1 st 2 nd zone 5 zone 6 zone 17 zone 18 Q 28 ZONE 7/8 REPORT Q 34 ZONE 19/20 REPORT [3030] 1 st 2 nd 1 st 2 nd [3030] 1 st 2 nd 1 st 2 nd zone 7 zone 8 zone 19 zone 20 Q 29 ZONE 9/10 REPORT Q 35 ZONE 21/22 REPORT [3030] 1 st 2 nd 1 st 2 nd [3030] 1 st 2 nd 1 st 2 nd zone 9 zone 10 zone 21 zone 22 Q 30 ZONE 11/12 REPORT Q 36 ZONE 23/24 REPORT [3030] 1 st 2 nd 1 st 2 nd [3030] 1 st 2 nd 1 st 2 n zone 11 zone 12 zone 23 zone 24 QUESTIONS 37 49: SYSTEM REPORT CODES Q 37 DURESS/AC LOSS Q 44 BYPASS/TROUBLE [AA88] 1 st 2 nd 1 st 2 nd [AAFF] bypss rest. fire trbl zone trbl duress AC loss Q 38 KEYPAD & #/BAT LOSS Q 45 WALK TEST [2299] 1 st 2 nd 1 st 2 nd [AAAA] 1 st 2 nd 1 st 2 nd & # panic low batt download walk test Q 39 OPEN/CLOSE & RF JAM Q 46 EVENT LOG [AAAA] open close RF jam [AAAA] 1 st 2 nd 1 st 2 nd 90% full 100% full Q 40 KEYPAD 7 & 9/1 & 3 Q 47 RF SUPERVISION [AAAA] 1 st 2 nd 1 st 2 nd [AAAA] RF sprv zn tmp low bat trble rst. 7 & 9 panic 1 & 3 panic Q 41 KEY TAMPER/CS TEST Q 48 ARM DISABLE/CLOCK SET [AAAA] 1 st 2 nd 1 st 2 nd [AAAA] 1 st 2 nd 1 st 2 nd key tamper CS test arm disable Q 42 FALSE ALARM Q 49 UP-ABOUT/CLOCK FAIL [AAAA] 1 st 2 nd 1 st 2 nd [AAAA] 1 st 2 nd 1 st 2 nd Q 43 Exit recent lockout cancel BELL SUPER/KEYPAD TAMP [AAAA] 1 st 2 nd 1 st 2 nd bell suprv kypd tmpr up & about clock set clock fail Q 50 1st RF ZONE/1st DBLD ZONE [0700] First RF Zone First Doubled Zone QUESTIONS 51 53: CROSSED ZONES L3-L4 Cross Zone Time (secs.) L3-L4 Cross Zone Time (secs.) A B C D E F 240 Q 51 Q 52 CROSSED ZONES GROUP 1 First zone Second zone CROSSED ZONES GROUP 2 First zone Second zone Q 53 CROSSED ZONES TIME _X _ _ X_ Grp 1 Grp 2 (see chart) UL: Q51-Q53 crossed zones must be disabled. N9967PRV3 4/04 Rev. A

11 SUBMODE 3: WIRELESS TRANSMITTER PROGRAMMING While in Installer Mode 1, press [ ] + [BYPASS], then select submode [3]. The display shows the following: Q#01 M3 Edit L:01 DATA: 00 ZR401 QUESTIONS 01-24: WIRELESS ZONE CONFIGURATION/SERIAL NUMBER All zone defaults = [000 ] Zones Enbl RF Transmitter 7-digit serial number Q 01 ZONE 1 Q 13 Zones Enbl RF Transmitter 7-digit serial number ZONE 13 Q 02 ZONE 2 Q 14 ZONE 14 Q 03 ZONE 3 Q 15 ZONE 15 Q 04 ZONE 4 Q 16 ZONE 16 Q 05 ZONE 5 Q 17 ZONE 17 Q 06 ZONE 6 Q 18 ZONE 18 Q 07 ZONE 7 Q 19 ZONE 19 Q 08 ZONE 8 Q 20 ZONE 20 Q 09 ZONE 9 Q 21 ZONE 21 Q 10 ZONE 10 Q 22 ZONE 22 Q 11 ZONE 11 Q 23 ZONE 23 Q 12 ZONE 12 Q 24 ZONE 24 QUESTIONS 25 32: KEYFOB CONFIGURATION/SERIAL NUMBER Zones Enbl RF Transmitter 7-digit serial number Q 25 KEYFOB 1 Q 26 KEYFOB 2 Q 27 KEYFOB 3 Q 28 KEYFOB 4 Zones Enbl RF Transmitter 7-digit serial number Q 29 KEYFOB 5 Q 30 KEYFOB 6 Q 31 KEYFOB 7 Q 32 KEYFOB 8 N9967PRV3 4/04 Rev. A

12 SUBMODE 4: DESCRIPTOR PROGRAMMING While in Installer Mode 1, press [ ] + [BYPASS], then select submode [4]. The display shows the following: Q#01 DESC ZNE:01 ZONE ONE 01 QUESTIONS 01 24: ZONE DESCRIPTORS FOR ZONES Enter up to 16 characters Q 01 ZN 1 Q 02 ZN 2 Q 03 ZN 3 Q 04 ZN 4 Q 05 ZN 5 Q 06 ZN 6 Q 07 ZN 7 Q 08 ZN 8 Q 09 ZN 9 Q 10 ZN 10 Q 11 ZN 11 Q 12 ZN 12 Q 13 ZN 13 Q 14 ZN 14 Q 15 ZN 15 Q 16 ZN 16 Q 17 ZN 17 Q 18 ZN 18 Q 19 ZN 19 Q 20 ZN 20 Q 21 ZN 21 Q 22 ZN 22 Q 23 ZN 23 Q 24 ZN 24 QUESTIONS 25 26: PARTITION DESCRIPTORS Enter up to 16 characters for each partition Q 25 PART. 1 Q 26 PART. 2 N9967PRV3 4/04 Rev. A

13 NOTES 13

14 NOTES 14

15 NOTES 15

16 165 Eileen Way, Syosset, New York Copyright 2004 Honeywell International Inc. ÊN9967PRV3gŠ N9967PRV3 4/04 Rev. A

FBII Security System. Programming Guide. Version 2.X. N9938PRV3 4/04 Rev. A

FBII Security System. Programming Guide. Version 2.X. N9938PRV3 4/04 Rev. A FBII Security System OMNI -848 OMNI -848EU Version 2.X Programming Guide N9938PRV3 4/04 Rev. A CONTENTS INSTALLER SUBMODE 1: SYSTEM OPTIONS... 4 Central Station Phone Numbers... 4 Pager Phone Numbers...

More information

First Alert 1200C Installer Notes M. Leuck

First Alert 1200C Installer Notes M. Leuck First Alert 2C Installer Notes M. Leuck. Programming can done by standard keypads 2. Enter programming with Installer Code + 8 + + 3. Another method of entering programming: Power system down, then back

More information

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96 Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96 XL-2G Gold Product Overview 7 Zones (6 programmable + panic or keyswitch zone) Fast Loop Response

More information

SECURITY SYSTEM 4110DL. Programming Form Programming Form Programming Form 4110DL-PRV3 10/96

SECURITY SYSTEM 4110DL. Programming Form Programming Form Programming Form 4110DL-PRV3 10/96 SECURITY SYSTEM 4110DL Programming Form Programming Form Programming Form 4110DL-PRV3 10/96 4110DL PROGRAMMING FORM FIELD FUNCTION [ ] = Default Value SYSTEM OPTIONS (*20-*28) *20 MASTER SECURITY CODE

More information

VISTA-100 Commercial Fire & Burglary Partitioned System

VISTA-100 Commercial Fire & Burglary Partitioned System VISTA-100 Commercial Fire & Burglary Partitioned System 4XLFN6WDUW Step-by Step Programming Procedure Single and Multiple Programming Forms System Worksheets FIRE FIRE * PULL VISTA-100PR Rev B 4/99 TABLE

More information

Property of Monitronics Inc

Property of Monitronics Inc Enter Program Press CODE key + * + 2468 + 1 (also try 2121) Installer Options Move to location Program location Exit Program Default Panel Hex Program Code + * + Installer Code + 1 = Enter Programming

More information

ADEMCO VISTA-10P ADEMCO VISTA-10PSIA Security Systems

ADEMCO VISTA-10P ADEMCO VISTA-10PSIA Security Systems ADEMCO VISTA-10P ADEMCO VISTA-10PSIA Security Systems Programming Guide K0735PRV5 3/15 Rev A COMPATIBILITY: This Programming Guide is intended for VISTA-10P/VISTA-10PSIA controls with firmware revision

More information

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide Digiplex System V2.14 / V2.2ACC Control Panel Programming Guide Table of Contents Getting Started...2 What Do I Do First?...2 How Do I Program the Control Panel?...2 Single Digit Entry Method...2 Multiple

More information

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. TABLE OF CONTENTS... P.1 2. GENERAL DESCRIPTION... P.2... 3. STANDARD AND OPTIONAL PARTS LIST... P.2... 4. FEATURE

More information

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX PROGRAMMING GUIDE SPECTRA CONTROL PANELS V1.2 1725, 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX TABLE OF CONTENTS HOW DO I PROGRAM THE SYSTEM?... 4 Single Digit Data Entry Method (Hexadecimal

More information

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure. Notice The material and instructions covered in this manual have been carefully checked for accuracy and are presumed to be reliable. However, Radionics, Inc. assumes no responsibility for inaccuracies

More information

CC488. Quick Reference Guide Solution Ultima 880

CC488. Quick Reference Guide Solution Ultima 880 CC488 EN Quick Reference Guide Solution Ultima 880 CC488 Quick Reference Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty

More information

VISTA-20PMT. Programming Guide. This control is a certified SIA-compliant control that meets SIA specifications for False Alarm Reduction.

VISTA-20PMT. Programming Guide. This control is a certified SIA-compliant control that meets SIA specifications for False Alarm Reduction. ARMED 7 INSTANT 8 CODE VISTA-15PMT VISTA-20PMT Programming Guide ARMED READY 1 OFF 4 MAX 7 INSTANT READY 0 2 AWAY 5 TEST 8 CODE # 3 STAY 6 BYPASS 9 CHIME READY 1 OFF ON OFF 4 MAX 5 TEST 2 AWAY 3 STAY 6BYPASS

More information

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160 All-In-One Wireless Security System V3.2 Programming Guide Model # MG6130 / MG6160 We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com

More information

GEM-P800 Programming Instructions

GEM-P800 Programming Instructions NOTE After 15 minutes of keypad inactivity the keypad will emit a steady tone indicating the panel has been left in Dealer Program Mode Enter Dealer Code to exit or press the key to return to Dealer Program

More information

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION...2 STANDARD AND OPTIONAL PARTS LIST...2 FEATURE DEFINITIONS...3 TERMINAL DRAWING AND SPECIAL NOTES...4

More information

CC408. Quick Reference Guide Solution 880

CC408. Quick Reference Guide Solution 880 CC408 EN Quick Reference Guide Solution 880 CC408 Quick Reference Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty Ltd ( Bosch

More information

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION... 2 STANDARD AND OPTIONAL PARTS LIST... 2 PARTS DIAGRAM... 3 TERMINAL DRAWING AND SPECIAL NOTES...

More information

Property of Monitronics Inc

Property of Monitronics Inc Enter Program Program Location 1. Hold 8 key for 3 seconds, keypad will beep 2. Enter 4 5 6 7 8 9, display should show dash on display 1. Press [B/A] key display will show 3 dashs 2. Enter 3-digit location

More information

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION... 2 2. STANDARD AND OPTIONAL PARTS LIST... 2 3. FEATURE DEFINITIONS... 3 4. TERMINAL DRAWING AND SPECIAL

More information

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION...P.2 2. STANDARD AND OPTIONAL PARTS LIST...P.2 3. FEATURE DEFINITIONS...P.3 4. TERMINAL DRAWING AND

More information

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4 Programming Guide We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com

More information

2000 Series. Program Entry Guide. Control Panels

2000 Series. Program Entry Guide. Control Panels 2000 Series EN Program Entry Guide Control Panels 2000 Series Program Entry Guide About This Manual EN 2 About This Manual This guide describes the programming parameters available to the 2000 Series Control

More information

Control/Communicator Installation Manual

Control/Communicator Installation Manual DAS NETWORX NX-12 Control/Communicator Installation Manual General Description...2 Ordering Information...2 Option Definitions...3 Programming the LED Code Pads...5 Programming the NX-12...9 Types of Programming

More information

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E... 5$1*(5( DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS General Description... 2 Standard and Optional Parts List... 2 Feature Definitions... 3 Comments about the 8600E... 4 Terminal

More information

Installation Instructions

Installation Instructions NX-148E-RF LCD Touchpad with Receiver 466-2198C February 2006 Copyright 2006, GE Security Inc. Contents Product summary 1 Installation 1 Transmitter programming 2 Touchpad programming 5 Reference tables

More information

NetworX Series NX-6 CONTROL PANEL. Installation and Startup

NetworX Series NX-6 CONTROL PANEL. Installation and Startup NetworX Series NX-6 CONTROL PANEL Installation and Startup 25 GE Security All rights reserved. These instructions do not purport to cover all details or variations in equipment nor to provide every possible

More information

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION...P.2 2. STANDARD AND OPTIONAL PARTS LIST...P.2 3. FEATURE DEFINITIONS...P.3 4. TERMINAL DRAWING AND

More information

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master) User Codes (1-6 digits) Access Levels Access Levels + Time Control User 1 (Master) 1 1 2 3 25 49 73 0 User 2 2 26 50 74 0 User 3 3 27 51 75 0 User 4 4 28 52 76 0 User 5 5 29 53 77 0 User 6 6 30 54 78 0

More information

FBII Security System. Installation and Setup Guide. Version 2.0. N9938V4 8/06 Rev. A

FBII Security System. Installation and Setup Guide. Version 2.0. N9938V4 8/06 Rev. A FBII Security System OMNI -848 OMNI -848EU Version 2.0 Installation and Setup Guide N9938V4 8/06 Rev. A THANK YOU for your purchase of the OMNI -848 Security System. The purpose of this manual is to give

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING -961212-0004 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. ( 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2) Connect

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING 48ESEP-01 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2)

More information

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup NetworX Series NX-8 Commercial Fire Panel Installation and Startup 2004 GE Security All rights reserved. Printed in the United States of America. These instructions do not purport to cover all details

More information

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS Feature Charts Control Panels FEATURE CHART LYNX Plus (L3000) (Supported Feature) (Not Supported) N/A (Not Applicable) LYNX Touch (L5210)

More information

NetworX Series NX-4V2 Control Panel Installation and Startup

NetworX Series NX-4V2 Control Panel Installation and Startup NetworX Series NX-4V2 Control Panel Installation and Startup 2005 GE Security All rights reserved. These instructions do not purport to cover all details or variations in equipment nor to provide every

More information

Radionics D4112 Program Sheet

Radionics D4112 Program Sheet Programming only by downloading, 5200 Programmer or 5100 "Wand" Programmer Plug programmer in and momentarily short Reset Pin to Terminal 25 to enable program mode 1. Account Account # I I I I I (0 to

More information

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68) F A 1 7 0 0 c Testing the System Battery Test When AC power is present, the FA1700C runs a brief battery test every 60 seconds to determine if there is a battery connected, and runs an extended battery

More information

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide MG6250 2-Partition 64-Zone Wireless Console with GPRS/GSM Version.6 Section Programming Guide Things You Need to Know About this Programming Guide The MG6250 All-in-one Wireless Console can be programmed

More information

Series. NX-4-EUR Control Panel. Installation manual

Series. NX-4-EUR Control Panel. Installation manual g GE Security NetworX TM Series NX-4-EUR Control Panel Installation manual CONTENTS CONTENTS...2 GENERAL INFORMATION...4 ORDERING INFORMATION...4 FEATURE DEFINITIONS...5 PROGRAMMING THE NX-4 KEYPADS...12

More information

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual WIC-16Z4P WIC-5Z2P Installation & Operation User Manual Page : 1/34 INDEX # Function Page 1 Abort Current Communication and Clear Reporting Queue (*59) 13 2 Abort Current Communications (*59) 10 3 Account

More information

ADEMCO CONTACT ID REPORTING (revised )

ADEMCO CONTACT ID REPORTING (revised ) ADEMCO CONTACT ID REPORTING (revised 7-9-2004) Contact ID reporting takes the following format: CCCC Q EEE GG ZZZ CCCC = customer (subscriber account number) Q = event qualifier, E = new event, R = restore

More information

VISTA-128FB. Quick Start Guide. Commercial Fire & Burglary Partitioned Security System. with Scheduling.

VISTA-128FB. Quick Start Guide. Commercial Fire & Burglary Partitioned Security System. with Scheduling. VISTA-128FB Commercial Fire & Burglary Partitioned Security System with Scheduling Quick Start Guide V128FB-PR 5/98 2 Table Of Contents RECOMMENDED PROGRAMMING PROCEDURE... 4 PROGRAM FIELD CATEGORIES...

More information

USER GUIDE HARDWIRED CONTROL PANELS

USER GUIDE HARDWIRED CONTROL PANELS USER GUIDE HARDWIRED CONTROL PANELS Scantronic Contents 1. Introduction... 3 The Alarm System... 3 The Keypads... 3 The 725r Remote Setting Device... 6 About This Guide... 6 2. Everyday Operation... 7

More information

1728EX, 1728, 1738EX AND 1738 SYSTEM PROGRAMMING GUIDE

1728EX, 1728, 1738EX AND 1738 SYSTEM PROGRAMMING GUIDE DEFAULT INSTALLER CODE 0000 / 000000 (see section [281] on page 17) DEFAULT SYSTEM MASTER CODE 1234 / 123456 (see section [301] on page 17) HOW DO I ENTER PROGRAMMING MODE? STEP 1: Press [ENTE R] STEP

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING -961212-0004 SOFTWARE VERSI 3.10 CTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2)

More information

Safewatch Pro 3000EN Entrepreneur 3000EN Security Manager 3000EN

Safewatch Pro 3000EN Entrepreneur 3000EN Security Manager 3000EN ARMED READY OFF INSTANT READY AWAY TEST CODE STAY BYPASS CHIME ARMED READY OFF INSTANT READY AWAY TEST CODE STAY BYPASS CHIME Safewatch Pro 3000EN Entrepreneur 3000EN Security Manager 3000EN Security Systems

More information

INSTALLATION MANUAL & PROGRAM RECORD SHEET

INSTALLATION MANUAL & PROGRAM RECORD SHEET INSTALLATION MANUAL & PROGRAM RECORD SHEET TABLE OF DESCRIPTION CONTENTS PAGE WIRING MANUAL 2-6 MENU CHART 7 INSTALLER FUNCTIONS 8 MENU 1 SYSTEM TIMES 9 MENU 2 ZONE CONFIGURATION 10-14 MENU 3 SYSTEM OPTIONS

More information

System Programming Guide

System Programming Guide & System Programming Guide Software Versions 4.4 (728ULT) and 4.1 (738ULT) Installer Code (Default - 728 Ultra: 282828; 738 Ultra: 383838) Full access to programming, except user access codes (PINs). No

More information

PROGRAMMING INSTRUCTIONS

PROGRAMMING INSTRUCTIONS R PROGRAMMING INSTRUCTIONS Publicly traded on NASDAQ Symbol: NSSC HARDWIRE WIRELESS GEM-P1664 CONTROL PANEL/COMMUNICATOR Programming the GEM-P1664 Control Panel with the "Classic" GEM-RP1CAe2 Keypad and

More information

RE6100 Series Helix Security and Automation Platform

RE6100 Series Helix Security and Automation Platform CONFIGURATION Resolution Compatibles RE6100 Series Helix Security and Automation Platform C G UI D E Configuration Settings Table 1 - Panel Settings Table 2 - Zone Settings Table 3 - Device Settings Table

More information

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147) -961112-0003 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3

More information

Installation Instructions

Installation Instructions g 466-2339A October 2009 2009 GE Security, Inc. Introduction This is the GE. Installations should only be done by trained professionals. Use this document to install the system with default settings that

More information

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: -961112-0002 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3

More information

Programming Worksheets

Programming Worksheets WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully

More information

Control/Communicator

Control/Communicator Architectural & Engineering Specifications Control/Communicator 1.0 GENERAL... 2 1.1 SCOPE OF WORK... 2 1.1.1 Introduction... 2 1.2 GENERAL CONDITIONS... 2 1.2.1 After-Sales Support... 2 1.2.2 Quality

More information

4-PGM Expansion Module

4-PGM Expansion Module 4-PGM Expansion Module APR3-PGM4 = Default setting SECTION [001] : General Options SECTION [002] : PGM Options Option OFF ON Option OFF ON [1] Future Use N/A N/A [1] PGM1 Deactivation After Deactivation

More information

/10 Rev A

/10 Rev A VISTA-128BPT/ VISTA-250BPT/ VISTA-128BPTSIA Commercial Burglary Partitioned Security System With Scheduling User Guide 800-06905 6/10 Rev A Your Honeywell security system is designed for use with devices

More information

Table of Contents. All-In-One Wireless Security System V1.3. Programming Guide. Model # MG-6060 / MG-6030

Table of Contents. All-In-One Wireless Security System V1.3. Programming Guide. Model # MG-6060 / MG-6030 All-In-One Wireless Security System V1.3 Programming Guide Model # MG-6060 / MG-6030 Table of Contents Things You Should Know... 2 About This Programming Guide... 2 Conventions... 2 Installer Code (Default:

More information

PROGRAMMING INSTRUCTIONS

PROGRAMMING INSTRUCTIONS R PROGRAMMING INSTRUCTIONS Publicly traded on NASDAQ Symbol: NSSC HARDWIRE WIRELESS GEM-P9600 CONTROL PANEL/COMMUNICATOR Programming the GEM-P9600 Control Panel with the "Classic" GEM-RP1CAe2 Keypad and

More information

8-zone Expansion Module

8-zone Expansion Module 8-zone Expansion Module APR3-ZX8 SECTION [001] : General Options Option OFF ON [1] Tamper Recognition ON = Input 8 (Z8) becomes tamper input = Default setting Disabled Enabled [2] PGM Deactivation After

More information

All-In-One Wireless Security System V1.0. Model # MG Programming Guide

All-In-One Wireless Security System V1.0. Model # MG Programming Guide All-In-One Wireless Security System V1.0 Model # MG-6060 Programming Guide Things You Should Know... 4 About This Programming Guide... 4 Conventions... 4 Installer Code (Default: 0000 / 000000)... 4 Maintenance

More information

Quick Programmer s Manual

Quick Programmer s Manual Version 2.604 (31/03/05) p1 Quick Programmer s Manual 2005. Inner Range Pty. Ltd. Part Number: 630048V2 p2 Version 2.604 (31/03/05) TABLE OF CONTENTS. 1. PROGRAMMING FLOWCHART. The following flowchart

More information

Security System With Scheduling. User Guide. N5943-8V4 7/04 Rev A

Security System With Scheduling. User Guide. N5943-8V4 7/04 Rev A ADEMCO VISTA-120 Security System With Scheduling User Guide N5943-8V4 7/04 Rev A Your Honeywell security system is designed for use with devices manufactured or approved by Honeywell for use with your

More information

XT30/XT50 PROGRAMMING PART 2. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training Programming- Part 2. Bell Options

XT30/XT50 PROGRAMMING PART 2. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training Programming- Part 2. Bell Options Slide 1 XT30/XT50 Basic Training Programming- Part 2 Slide 2 Objectives After completing this course you will: 1) Understand how to prepare the panel for programming and how to access the built-in programmer.

More information

Contact ID as of 2/2/2015

Contact ID as of 2/2/2015 Contact ID as of 2/2/2015 100 Medical Zone A non-specific medical exists 101 Personal Emergency Zone Emergency Assistance request 102 Fail to report in Zone A user has failed to activate a monitoring device

More information

EasyLoader. Integrated Alarm Control/Communicator. Year 2000 ready. Express Installation and Operation Manual. Edition II

EasyLoader. Integrated Alarm Control/Communicator. Year 2000 ready. Express Installation and Operation Manual. Edition II EasyLoader AV-2004, AV-2048 Integrated Alarm Control/Communicator Year 2000 ready Express Installation and Operation Manual Version 3.06 (with very slow zone) Edition II This product is subject to continual

More information

Contact ID as of 11/28/2018

Contact ID as of 11/28/2018 Contact ID as of 11/28/2018 100 Medical Zone A non-specific medical exists 101 Personal Emergency Zone Emergency Assistance request 102 Fail to report in Zone A user has failed to activate a monitoring

More information

USER GUIDE HARDWIRED CONTROL PANELS

USER GUIDE HARDWIRED CONTROL PANELS USER GUIDE HARDWIRED CONTROL PANELS Contents 1. Introduction... 3 The Alarm System... 3 The Keypads... 3 The 725r Telecommand (Remote Setting Device)... 5 About This Guide... 5 2. Everyday Operation...

More information

ADEMCO VISTA SERIES VISTA-21iP / VISTA-21iPSIA Security Systems

ADEMCO VISTA SERIES VISTA-21iP / VISTA-21iPSIA Security Systems ADEMCO VISTA SERIES VISTA-21iP / VISTA-21iPSIA Security Systems Programming Guide K14488PRV3 10/12 Rev B RECOMMENDATIONS FOR PROPER PROTECTION The Following Recommendations for the Location of Fire and

More information

NX-4V2 Control Panel Installation Instructions

NX-4V2 Control Panel Installation Instructions 4V2 Control Panel Installation Instructions Introduction This is the 4V2-Control Panel Installation Instructions. Installations should only be done by trained professionals. Use this document to install

More information

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0 User s Guide SUB-MA7240O-0001.OG.Solution40-111.doc Created: 6/05/03 Last Updated: 23/09/03 MA7240AO-0001 Version 1.0 2 Table Of Contents User List...6 Quick Reference..7 Features...7 Keypad User's Guide...8

More information

Summit 3208GLD USER MANUAL. Electronics Line

Summit 3208GLD USER MANUAL. Electronics Line Summit 3208GLD USER MANUAL Electronics Line Table of Contents 1: Introduction... 2 2: Overview... 3 3: Keypad Functions... 4 3.1: Keypads... 4 3.2: 3108 LCD Keypad Layout... 4 4: Basic System Operation...

More information

USER GUIDE HARDWIRED CONTROL PANELS

USER GUIDE HARDWIRED CONTROL PANELS USER GUIDE HARDWIRED CONTROL PANELS Contents 1. Introduction... 3 The Alarm System... 3 The Keypads... 4 The 725r Telecommand (Remote Setting Device)... 5 About This Guide... 5 2. Everyday Operation...

More information

LYNX Touch Security System

LYNX Touch Security System LYNX Touch Security System Programming Guide ARMED READY 800-06895 3/11 Rev. A Table of Contents Entering Programming Mode... 3 Programming the Data Fields... 3 Loading a Default Set... 3 Exiting Programming

More information

Solution 6+6 Wireless On/Off Installation Manual ISSUE 1.20

Solution 6+6 Wireless On/Off Installation Manual ISSUE 1.20 Solution 6+6 Wireless On/Off Installation Manual ISSUE 1.20 MA670I This page has been included for you to cut out and insert into the spine of the folder Solution 6+6 Wireless On/Off Installation Manual

More information

CHEAT SHEET: SPECTRA V2.1

CHEAT SHEET: SPECTRA V2.1 CHEAT SHEET: SPECTRA V2.1 Zone mapping Device connected To which input? NO ATZ WITH ATZ CONTROL PANEL INPUT 1= ZONE 1 ZONE 1 & 6 INPUT 2= ZONE 2 ZONE 2 & 7 INPUT 3= ZONE 3 ZONE 3 & 8 INPUT 4= ZONE 4 ZONE

More information

SENTROL ZX400/ZX410. Security System Control. Programming

SENTROL ZX400/ZX410. Security System Control. Programming SENTROL ZX400/ZX410 Security System Control Programming 1 2 TABLE OF CONTENTS Table of Contents Operating the System... 5 Introduction...5 Powering Up With the Control Station...5 Control Stations...6

More information

Solution 6+6 Wireless - AE Installation Manual ISSUE 1.10

Solution 6+6 Wireless - AE Installation Manual ISSUE 1.10 Solution 6+6 Wireless - AE Installation Manual ISSUE 1.10 MA660I Solution 6+6 This page has been included for you to cut out and insert into the spine of the folder Wireless AE Installation Manual ISSUE

More information

Solution 862 Installation Manual ISSUE 1.30

Solution 862 Installation Manual ISSUE 1.30 Solution 862 Installation Manual ISSUE 1.30 MA406I This page has been included for you to cut out and insert into the spine of the folder Solution 862 Installation Manual ISSUE 1.30 (61-2) 9672 1233 Solution

More information

Training Manual Multi-Language with Wireless

Training Manual Multi-Language with Wireless Training Manual Multi-Language with Wireless Installer Training Firmware Version 2.3 X16 Stock Code: 860-1-473-X16 X64 Stock Code: 860-1-864-XS 2 Contents IDS X Series Training V2.3 Contents Contents 3

More information

ADEMCO VISTA-12A ADEMCO VISTA-12E

ADEMCO VISTA-12A ADEMCO VISTA-12E ADEMCO VISTA-12A ADEMCO VISTA-12E Security Systems User Guide K10021-1 9/04 Rev. A Table of Contents Burglary System Features... 3 Basic Features... 3 Exit/Entry Delays... 3 Before Arming (Ready [ ] Key)...

More information

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging 1.1 Specifications System Introduction S E C T I O N 1 Control Panel Specifications Flexible Zone Configuration: 8 Fully Programmable Zones 38 Access Codes: 32 User, 1 System Master, 2 Partition Master,

More information

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2 Architectural & Engineering Specifications Control Panel 1.0 GENERAL... 2 1.1 SCOPE OF WORK... 2 1.1.1 Introduction... 2 1.2 GENERAL CONDITIONS... 2 1.2.1 After-Sales Support... 2 1.2.2 Quality assurance...

More information

GEM-P801 Control Panel/Communicator For use with the GEM-RP8 or the GEM-K800 Keypads. Installation Instructions

GEM-P801 Control Panel/Communicator For use with the GEM-RP8 or the GEM-K800 Keypads. Installation Instructions 333 Bayview Avenue Amityville, New York 11701 For Sales and Repairs, (800) 645-9445 For Technical Service, (800) 645-9440 Publicly traded on NASDAQ Symbol: NSSC GEM-P801 Control Panel/Communicator For

More information

ADEMCO VISTA-12A ADEMCO VISTA-12E Security Systems

ADEMCO VISTA-12A ADEMCO VISTA-12E Security Systems ADEMCO VISTA-12A ADEMCO VISTA-12E Security Systems User Guide K10021-1V1 10/05 Rev. A SYSTEM COMPATIBILITY NOTICE Your Honeywell security system is designed for use with devices manufactured or approved

More information

ADEMCO VISTA-48 SERIES

ADEMCO VISTA-48 SERIES ADEMCO VISTA-48 SERIES Security Systems User Guide This control complies with EN50131-3:2009 and conforms to UL requirements. K0750ENV2 5/11 Rev. A Table of Contents Burglary System Overview...3 Basic

More information

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ READY ARMED READY 1 OFF 7 INSTANT 2 AWAY 8 CODE 6BYPASS 9 CHIME 9,67$%3 9,67$%3 &RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ 8VHU*XLGH ARMED READY 1 OFF 2 AWAY 3 STAY 4 MAX 5 TEST 6 BYPASS

More information

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1 1.1 PC5015 Specifications System Introduction S E C T I O N 1 Flexible Zone Configuration: 8 Fully Programmable Zones 38 Access Codes: 32 User, 1 System Master, 2 Partition Master, 2 Duress and 1 maintenance

More information

$'(0&2 9,67$ 3DUWLWLRQHG 6HFXULW\ 6\VWHP 8VHU *XLGH N7003V3 5/04 Rev A

$'(0&2 9,67$ 3DUWLWLRQHG 6HFXULW\ 6\VWHP 8VHU *XLGH N7003V3 5/04 Rev A $'(0&29,67$ 3DUWLWLRQHG6HFXULW\6\VWHP 8VHU*XLGH N7003V3 5/04 Rev A 2 TABLE OF CONTENTS SYSTEM OVERVIEW...5 General...5 A Partitioned System...5 Zones...5 Fire Protection...6 Burglary Protection...6 Alarms...6

More information

GEM-P800. Control Panel/Communicator. Installation Instructions

GEM-P800. Control Panel/Communicator. Installation Instructions GEM-P800 Control Panel/Communicator Installation Instructions NAPCO 2002 WI850C 9/02 WI850C GEM-P800 Installation Instructions Table of Contents General Information GEM-P800 Features General Information...

More information

AXI LED USER MANUAL (REV. 1.0)

AXI LED USER MANUAL (REV. 1.0) Security & Home Automation System AXI LED USER MANUAL (REV. 1.0) CONTENTS PREFACE FEATURES LED KEYPAD OUTLOOK 1.0 LIGHT INDICATION 1 2 4 6 CHAPTER 1: ALARM SYSTEM CONTROL 1.0 USING LED KEYPAD 1.0.1 ARMING

More information

Type Report Report Date: 1/21/2015

Type Report Report Date: 1/21/2015 Type Report Report Date: 1/21/2015 IPRS000101 Paradox IPRS7 CMSI Template Type No Description Action Plan 1 Account Supervision Lost System Alarm 2 Account Supervision Restored Restoral, No Alarm 3 Account

More information

VISTA-128BPT/ VISTA-250BPT/ VISTA-128BPTSIA

VISTA-128BPT/ VISTA-250BPT/ VISTA-128BPTSIA VISTA-128BPT/ VISTA-250BPT/ VISTA-128BPTSIA Commercial Burglary Partitioned Security System With Scheduling User Guide 800-06905 6/10 Rev. E IMPORTANT! RECOMMENDATIONS FOR PROPER INTRUSION PROTECTION For

More information

VISTA-32FBPT. Commercial Fire and Burglary Partitioned Security Systems with Scheduling. User Guide /12 Rev. B

VISTA-32FBPT. Commercial Fire and Burglary Partitioned Security Systems with Scheduling. User Guide /12 Rev. B VISTA-32FBPT Commercial Fire and Burglary Partitioned Security Systems with Scheduling User Guide 800-11045 2/12 Rev. B 2 TABLE OF CONTENTS SYSTEM OVERVIEW...5 General...5 A Partitioned System...5 Zones...6

More information

Content. 1. Introduction to the IDS Features Installation and Wiring End-of-Line Resistors/Tamper per Zone...

Content. 1. Introduction to the IDS Features Installation and Wiring End-of-Line Resistors/Tamper per Zone... 1 2 Content 1. Introduction to the IDS 805... 7 1.1 Features...7 2. Installation and Wiring...8 3. End-of-Line Resistors/Tamper per Zone...9 4. Connecting the Telephone Communicator...10 5. Programmable

More information

LYNXR-2 Series Security System

LYNXR-2 Series Security System For Service Call: (866) 401-4842 LYNXR-2 Series Security System User Guide ARMED READY OFF 1 2 3 ESCAPE RECORD VOLUME AWAY 4 5 6 PLAY ADD STAY LIGHTS ON TEST BYPASS 7 8 9 DELETE LIGHTS OFF CODE CHIME AUX

More information

LYNX ,QVWDOODWLRQ,QVWUXFWLRQV. ALPHA DRAFT. June 5, 1998 N8889 5/98 OFF AWAY STAY AUX

LYNX ,QVWDOODWLRQ,QVWUXFWLRQV.  ALPHA DRAFT. June 5, 1998 N8889 5/98 OFF AWAY STAY AUX LYNX Security System,QVWDOODWLRQ,QVWUXFWLRQV ALPHA DRAFT June 5, 1998 OFF AWAY STAY AUX N8889 5/98 RECOMMENDATIONS FOR PROPER PROTECTION The Following Recommendations For The Location Of Fire And Burglary

More information

ADEMCO LYNX XL SERIES Security System

ADEMCO LYNX XL SERIES Security System ADEMCO LYNX XL SERIES Security System LXL-1010 Installation and Setup Guide BETA DRAFT COPY 8/23/04 K9349-1 8/04 Rev. A RECOMMENDATIONS FOR PROPER PROTECTION The Following Recommendations for the Location

More information

0$(6752 0$(6752. Programming Guide. 6 and 10 Zone Alarm Control Panel ,1752'8&7,21 +(;$ 352*5$00,1* 675($0/,1(' 6(&7,21 352*5$00,1* FIGURE 1 FIGURE 2

0$(6752 0$(6752. Programming Guide. 6 and 10 Zone Alarm Control Panel ,1752'8&7,21 +(;$ 352*5$00,1* 675($0/,1(' 6(&7,21 352*5$00,1* FIGURE 1 FIGURE 2 0$(6752 0$(6752 6 and 10 Zone Alarm Control Panel Programming Guide,1752'8&7,21 The Maestro-600 and Maestro-1000 alarm control panels enable reduced number of programming steps. End-users can access most

More information