Leakage Detection. WaterAlarmSystems Fuel-oil/WaterAlarms. Safe protection for plants and buildings...leakage Detection Systems provided by BARTEC

Size: px
Start display at page:

Download "Leakage Detection. WaterAlarmSystems Fuel-oil/WaterAlarms. Safe protection for plants and buildings...leakage Detection Systems provided by BARTEC"

Transcription

1 Leakage Detection WaterAlarmSystems Fuel-oil/WaterAlarms Safe protection for plants and buildings...leakage Detection Systems provided by BARTEC

2 Reservation Technical data is subject to change without notice. No claims for damages arising from changes, errors or misprints shall be allowed. Attention is drawn to the applicable standards and regulations together with the relevant operating and installation instructions. Delivery only via authorized retailer. Issue 01/05 BARTEC GmbH

3 Contents Sensors SCR sensor cables 2 PS point sensor 3 Electronic monitoring units RLW electronic monitoring unit with leakage locating function, wall-mounted type 4-5 RDW 03 electronic monitoring unit without leakage locating function, wall-mounted type 6 RDA 01 electronic monitoring unit, without leakage locating function, rack-mounting type 7 Fuel Oil/Water Alarms HMW fuel oil/water alarm wall-mounted 8 HMS fuel oil/water alarm plug-socket type 9 Planning and design Notes for planning and design of water-alarm systems Installation and connection examples 12 1

4 Leakage Detection Systems Sensors SCR sensor cables The SCR sensor cable is used for detection of conductive liquids such as water, acids and alkalis. The sensor cable provides a precise location of the leakage. The SCR takes the form of a flexible, four-core, round-section cable with a protective braiding. Features Fast and easy installation High flexibility, supplied complete with connectors or by the meter Technical data Sensors 2 x 0.25 mm² Protected with partially permeable PTFE insulation Colour: red/white Return cores 2 x 0.25 mm², with FEP; Colour: red/white Protective braiding FEP; Colour: natural Cable diameter 5 mm Minimum bend radius 6 x cable diameter Tensile strength 210 N Temperature stability - 50 C to C Fire performance V 0 according to Fire-safety Standard UL 1581 SCR ordering data Order no. Order no. SCR sensor cable 1 m, with connectors 17-85M1-1761/ m, with connectors 17-85M1-1761/ m, with connectors 17-85M1-1761/ m, with connectors 17-85M1-1761/ m, with connectors 17-85M1-1761/5700 by the meter 17-85M Accessories Connecting cable 5 m, with connectors Connecting cable 5 m, with connectors SCR terminal connector SCR terminating resistance SCR zone divider module SCR T-branch 17-85Z Fixing tape (pack 50 items) Marking plate Sensitive sensor cable" " SCR connector fitting set SCR socket fitting set SCR test module Basic requirements for one sensor connection: sensor cable, 1 item SCR terminating resistance or 1 end connector for RLW, 1 item SCR connector, 2 items SCR sockets

5 PS point sensor The point sensor is used for detection of conductive liquids, such as water, for example. This point sensor gives a quick and reliable indication of a leakage. Features Individual connecting lengths Series installation, up to 50 point sensors can be connected Can be combined with the SCR sensor cable Locating function possible Technical data Type Flat point sensor with cable gland and watertight connecting-terminal chamber Dimensions 80 mm x 26 mm height Cable gland M12 x 1.5, cable-diameter range 3 to 6.5 mm Housing material PVC Temperature stability - 10 C to + 50 C Leakage alarm from 3 mm water depth Electrodes Two, stainless steel Electrode spacing 25 mm Connecting terminals Screw-type terminals on input and output Miscellaneous Integrated terminating resistance RLW ordering data PS point sensor Order no M1-3832/0A00 3

6 Leakage Das neue Detection Wasserwarnsystem Systems mit Ortung Electronic monitoring units RLW electronic monitoring unit with locating function, wall-mounted type Features Open-text system display Fast and accurate leak location Monitoring lengths up to m System calibration is not required Simple integration into the building control system Can be combined with sensor cable and point sensor The system is used for monitoring of complete rooms or along pipework, can also be used for monitoring of individual items. Any leak is located with meter accuracy and displayed in the Building Control Center, guaranteeing rapid leak location, and permitting immediate corrective action. Performance features Up to m of sensor cable can be connected to each measuring channel Measuring channel can be subdivided into up to 50 zones (e.g. Zone 1: Sensor cable 0 m to 50 m) Zones can be entered in open text (e.g. Tradesmen s Area 3 or Air conditioner 8) Display with background illumination (4 x 20 characters) for open-text messages Sensor-break monitoring Power-failure monitoring Software-protected with password Intrinsic system self-monitoring (Watch-dog) Trilingual front-panel text Trilingual menus on display (German, English, French) Length unit: Meter or feet (selectable) 4

7 Technical data Design Dimensions Inputs Outputs Event memory Measuring accuracy Measuring method Date/time Operating elements Plastic housing for wall-mounting, with transparent cover, connecting-terminal chamber and cable glands 284 x 217 x 143 mm (W x H x D); (Dimension H not including cable gland) - Power supply (standard) 230 V AC or 115 V AC/50 to 60 Hz/8 VA or 12 V/24 V DC/7 W - Sensor connection - Two potential-free changeover contacts per measuring channel (3 A for 230 V AC) for signaling leakage - Two potential-free changeover contacts for Power-failure monitoring (fail safe): 3 A for 230 V AC - RS 232 interface (standard) and RS 485 (variant); Block-oriented, protected single-master protocol for connection to the Building Management System Storage of the 20 most recent events, with date, time and open text ± 0.1 % of upper limit of effective measuring range Conductive (conductive liquids > 30 µs) Automatic summer-/winter-time changeover Touch-type keyboard (for operation of all functions, including input of open text) Signals Visual: LED displays: On/Leak/Breakage/Fault Acoustic: Piezoelectric buzzer (can be switched on/off) Ambient temperature 0 C to + 50 C Degree of protection IP 65 RLW ordering data Order no. RLW electronic monitoring unit with locating function Single channel 17-85G Dual channel 17-85G RLW electronic monitoring unit with locating function and RS 485 Single channel Dual channel 17-85G G

8 Leakage Detection Systems RDW 03 electronic monitoring unit without leakage locating function, wall-mounted type Features Rapid leak detection Monitoring lengths up to m System calibration is not required Simple integration into the building monitoring system Can be combined with sensor cable and point sensor The system detects escaping liquids quickly and reliably. A visual and acoustic alarm is given. Potential-free contacts for signals to the Building Management System (BMS) and for control functions are set simultaneously. Technical data Type Wall-mounted type, with touch-type keyboard and separate connecting-terminal chamber Dimensions 166 x 160 x 84 mm (W x H x D) Inputs Power supply 230 V AC/50 to 60 Hz/8 VA or 24 V DC/7 W standard Sensor via two-wire line max. sensor cable length m max. 50 point sensors Outputs Alarm relays, two separate changeover contacts (6 A for 230 V AC/6 A for 24 V DC) Breakage/power-failure relays, 1 changeover contact for fail-safe function (6 A for 230 V AC/6 A for 24 V DC) Memory Alarm/breakage-relays memory Measuring method Conductive (conductive liquids > 2 µs) Reaction sensitivity Adjustable Self-monitoring Sensor breakage and power-failure Operating elements Two-stage Acknowledge/Cancel button (Stage 1: Buzzer off); On/Off button Signals Visual: LED displays: On/Alarm/Break Acoustic: Piezoelectric buzzer Ambient temperature 0 C to + 60 C Degree of protection IP 54 RDW 03 ordering data RDW 03 electronic monitoring unit without leakage locating function, wall-mounted type Order no F

9 RDA 01 electronic monitoring unit without leakage locating function, rack-mounting type Features Rapid leak detection Monitored lengths up to m System calibration is not required Simple integration into the Building monitoring system Can be combined with sensor cable and point sensor The system detects even small amounts of leakage quickly and reliably. A visual and acoustic alarm is given. Potential-free contacts for messages to the Building Management System (BMS) and for control functions are set simultaneously. Technical data Type Rack-mounted housing for Mounting Rail TS 35 Dimensions 22.5 x 82 x 101 mm (W x H x D) Inputs Power supply: Type V AC/50 to 60 Hz/1.2 VA Type V DC/0.8 W Sensor connected via two-wire line max. sensor cable length: m max. number of point sensors: 50 Outputs Collective-alarm relays, two changeover contacts (0.25 A for 230 V AC/1 A for 24 V DC) Memory Alarm/break-relays memory Measuring method Conductive (conductive liquids > 2 µs) Reaction sensitivity Adjustable Self-monitoring Sensor break and power-failure Operating elements Reset button Alarm Visual: LED displays: On/Alarm/Break Acoustic: Piezoelectric buzzer Ambient temperature - 25 C to + 60 C Degree of protection IP 20 RDA 01 ordering data Order no. RDA 01 electronic monitoring unit without leakage locating function, rack-mounted type 230 V AC 17-85F V DC 17-85F

10 Leakage Detection Systems Fuel Oil/Water Alarms HMW fuel oil/water alarm, wall-mounted The BARTEC alarm system provides indication of even the smallest fluid-leaks, e. g. water or fuel-oil, simply and reliably. The tiny sensor head can be installed even in narrow and extremely confined spaces, providing safety for your equipment. Features For water and fuel-oil leaks Ready to use Durable and maintenance-free Automatic reset after repair of leak Sensor break control Function The fuel-oil/water alarm consists of the monitoring device and the point-sensor. The monitoring device provides an alarm via an LED and an acoustic signal if liquid touches the sensor. A potential-free contact for further alarm generators and other devices, such as a siren, indicator light or shut-off valve is switched simultaneously. Directives and approvals Design homologation: DIBT/Z EMC Directive: 89/336/EWG Low Voltage Directive: 73/27/EWG Technical data Monitoring device Power supply 230 V AC/50 to 60 Hz/1,2 VA Ambient temperature - 10 C to + 60 C Displays LED green: On, LED red: Alarm Acoustic signal Potential-free contact 230 V AC/1 800 VA, 100 V DC/300 W Structure Polyester enclosure, IP 65 with cable clands Potection class II (double insulated) Dimensions 110 x 75 x 55 mm (W x H x D) Power-connector cable 1.5 m, shock proof plug Sensor Dimensions 36 x 16 x 6 mm (W x H x D) Connection cable 2.0 m, flexible PVC cable Structure sensor head PA, Injection-moulded, enclosure Measuring method Optical Ambient temperature - 10 C to + 60 C Sensetivity Alarm signal by getting approx. 3 mm fluid level Fixing via enclosed mounting-clip HMW ordering data HMW fuel oil/water alarm, wall-mounted Order no H

11 HMS fuel oil/water alarm, power-socket The BARTEC alarm system provides indication of even the smallest fluid-leaks, e. g. water and fueloil, simply and reliably. The tiny sensor head can be installed even in narrow and extremely confined spaces, providing safety for your equipment. Features For water/fuel-oil leaks Ready to use Durable and maintenance-free Automatic reset after repair of leak Sensor break control Function The fuel-oil/water alarm consists of the monitoring device and the point-sensor. The monitoring device provides an alarm via an LED if liquid touches the sensor and a further de-energizes the socket outlet at the same time. Directives and approvals Design homologation: DIBT/Z EMC Directive: 89/336/EWG Low Voltage Directive: 73/27/EWG Technical data Monitoring device Power supply 230 V AC/50 to 60 Hz/1.2 VA Ambient temperature - 10 C to + 60 C Displays LED green: On, LED red: Alarm Max. breaking capacity 230 V AC/1 800 VA, 100 V DC/300 W Structure PPO enclosure, IP 20 Protection class I (prot. each conductor) Dimensions 125 x 67 x 50 mm (W x H x D) Sensor Dimensions 36 x 16 x 6 mm (W x H x D) Connection cable 2.0 m, flexible PVC cable Structure Injection-moulded, PA enclosure Measuring method optical Ambient temperature - 10 C bis + 60 C Sensetivity Alarm signal by getting approx. 3 mm fluid level Fixing via enclosed mounting-clip HMS ordering data HMS fuel oil/water alarm, power-socket Order no H

12 Leakage Detection Systems Planning and design Notes for planing and design of water-alarm systems General notes for planning and installation in buildings with false floors/ceilings Preparation Listing of possible sources of danger (e.g. water pipes, airconditioning systems, etc.) Listing of endangered items and systems (e.g. computing centers, communications cabinets, valuable items, etc.) Marking of all sources of danger and endangered items on the building plan Sensor-system planning Place the route of the sensor cable(s), the location of the point sensors and the electronic monitoring unit(s) on the building plan. An installation diagram showing lengths in meters is not absolutely necessary if the RLW electronic monitoring unit is used, provided the rooms, spaces and objects to be monitored are clearly indicated on the plan. The leak location and zone can be displayed in open text. Monitoring of individual items using point sensors or short lengths of sensor cable. Monitoring of large-area rooms and zones using sensor cables. Install the sensor cable in a meandering pattern on the floor (recommended installation distance = 1 m, or twice the tile spacing). Systematic room/zone monitoring using sensor cable: Install the sensor cable on the floor immediately along the sources of danger, or completely enclosing the danger source. Between individual objects or rooms/zones which are not to be monitored, the sensor cable can be connected to a standard installation cable (e.g. LIYY 4 x 0.5 mm²). Connectors, couplings and zone dividers are provided for this purpose. T-branch junctions, which permit branching within the route of the sensor cable, are also available. Precise leak locating and breakage monitoring remain unaffected. Please request separate Notes on Planning for the T-branch junction. Planning of electronic monitoring units Determine the number and/or the zones of buildings, rooms, floors, areas, to be monitored. Leak-locating function necessary: Yes/No (Depending on item size and inspectability in case of leakage) The RDW and RDA type electronic monitoring units are used for monitoring applications in which no leakage locating function is required. Both sensor cables and point sensors can be connected. See data-sheet for performance features. The RLW type electronic monitoring unit is used for monitoring applications in which the leakage locating function is necessary. Both sensor cables and point sensors can be connected. See data-sheet for performance features. Number of electronic monitoring units A rational number of electronic monitoring units should in all cases be determined using the building plans. 10 Recommendation When a leakage alarm signal to the control room is supplemented by other functions (such as a the closure of individual water supply lines, for example) the planned number of electronic monitoring units should be increased, in order to achieve selective shut-down. The installation of one electronic monitoring unit per building or per zone is recommended in cases in which building sections and/or zones are widely separated from one another.

13 Installation Retrospective installation of sensor cables and/or point sensors behind false floors/ceilings is possible at any time. The sensor cable should be fixed directly to the painted and dust free floor. Features Simple, direct local connection of sensor cables/meter-lengths of cable to the connectors The highly flexible cable can be easily installed Lengths of cable pre-fitted with connectors, etc., enable rapid installation Easy to fix cabling with self-adhesive fixing tapes No dust is produced during installation, no drilling required (important fo cleanrooms, computing centres, etc.) Necessary installation documents Installation diagram System documentation, consisting of:, data-sheets, installation instructions, notes for installation, operating instructions, commissioning, operating instruction sheets, test report Time of installation All other work, including final cleaning, should have been completed before the sensor cable is installed; this eliminates the danger of damage to the sensor cable as a result of third-party work. Notes for sensor-cable installation The substrate must be dry and clean, and completely free of dust. The sensor cable should be fixed to the floor using self-adhesive fixing tapes at intervals of 1 m. The sensor cable must not be crushed by metal components, since the electronic evaluation system checks the cable for electrical resistance. Ensure that dripping condensed water from pipes or cooling/refrigeration systems is not able to affect the sensor cable. A non-detecting connecting cable or a protecting tube or hose must be used in wall penetration and other points of the building. Warning notices ("Caution! Sensitive sensor cable ) should be affixed at points at which the sensor cable could be subjected to damage. The sensor cable must be in contact with the surface to be monitored (installation over obstructions, such as flush-mounted cable routings, for example, is permissible provided leak-detection can be continued immediately after the obstruction). Enter the length of sensor cable installed on the installation diagram (particularly important in the case of part-lengths with T-branches). The sensor cable s insulation resistance must be checked during and after completion of the installation work before the system is activated (see Test Record). Commissioning and technical data: see System Documentation. Tender specifications and further information can be found at 11

14 Leakage Detection Systems Installation and connection examples 1. Installation under a false floor Telecommunications Equipment room Computing center Equipment room Plug connection Terminating connector Zone divider 10 m Leak reference point Connecting cable Sensor cable Air-conditioning system Monitoring unit List of materials Connecting cable Electronic monitoring unit SCR socket/scr connector Warning notices "Caution! Sensor cable, on item at intervals of 5 m SCR sensor cable Quantity Order no. Electronic monitoring unit RDA 01, rack-mounted type, 230 V AC 1 item 17-85F or RDA 01, rack-mounted type, 24 V DC 17-85F or RDW 03, wall-mounted type, 230 V AC 17-85F or RLW single-channel, with locating function 17-85G m approx. 1 m Sensor cable SCR, running meters 44 m 17-85M Accessories Fixing tapes, one item per meter Calculation of sensor-cable length: Area x 1.1 = cable length Example: 40 x 1.1 = 44 m 5 m SCR socket SCR terminating resistance or connector Connecting cable (state required length) 1 m SCR terminating resistance, 220 Ohm, for RDA, RDW 1 item or SCR terminating connector for RLW Fixing tape (pack 50 items) 1 item Warning notice "Sensitive sensors 9 item SCR connector, installation set 1 item SCR socket, installation set 2 item

15 2.Installation instructions for wall penetrations "Bare - unprotected" installation of the sensor cable through masonry is not permitted. The zone divider permits optimum separation of leakage detection between two rooms. The offset of the zone divider (10 m) must be taken into account in the installation diagram (see drawing). Example: 50 m sensor cable installed in Room 1 and 30 m sensor cable in Room 2. i.e., 80 m total cable length + 10 m zone divider. The electronic monitoring unit calibrates to 90 m. The connecting cable does not change the overall length. In the case of open-text signals on the display, the room designation can be stored in addition to the meter indication using the "Channel Zone menu. Zone 1: 0 to 50 m Text: e.g. Computer Room 1 Zone 2: 60 to 90 m Text: e.g. Computer Room 2 Up to 50 zones can be implemented. False floor Sensor cable to electronic system 50 m SCR sensor cable SCR zone divider (Offset: 10 m) Connecting cable SCR terminating connector 30 m SCR sensor cable Installation on vertical pipes Fixing tape 3. Installation on pipes Time of installation All pipe installation work must have been completed before the sensor cable is installed, in order to avoid damage to the sensor cable. Notes for sensor-cable installation The pipe must be dry and clean The sensor cable must be protected against condensation water or water from the exterior by means of an isolation system around the pipe Installation of the sensor cable in the open is not permissible if rain, snow or a wet environment may occur Note the technical data for the sensor cable and the connectors The sensor cable must not be crushed against metal items The sensor cable s insulation resistance must be checked during and after completion of the installation work Sensor cable Insulation Installation on horizontal pipes Fixing tape Pipe Sensor cable Sensor cable 13

16 BARTEC Your Partner for fuel-oil and water alarm systems BARTEC GmbH Max-Eyth-Straße 16 D Bad Mergentheim Phone: Fax: D-UK-BHT /02-BARTEC WerbeAgentur

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax: Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Phone: 040 807-0 Fax: 040 807-259 Alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC display

More information

Conductive Leakage detectors of the Leckstar range

Conductive Leakage detectors of the Leckstar range Conductive Leakage detectors of the Leckstar range with electrode and relay Jola Spezialschalter GmbH & Co. KG Klostergartenstr. 11 67466 Lambrecht (Germany) Tel. +49 6325 188-01 Fax +49 6325 6396 www.jola-info.de

More information

Hot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological

Hot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological Providing the comfort of instant hot water is the key requirement of any modern hot water system. The Raychem single-pipe system keeps water at the right temperature in a building s water distribution

More information

Consignes d installation

Consignes d installation PBS-200-A Single entry power junction box Installation Instructions PBS-200-A Single entry power junction box with cold applied connection technology for use with BARTEC PSB / HSB trace heaters Consignes

More information

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4 Areas of application The LSG4 alarm unit is used for monitoring industrial systems, e.g. in the following areas: Alarm and hazard stati in production e.g. for monitoring temperature and pressure in reactors

More information

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15 with coupling device AGH675-7 and AGH675-7MV15 Device combination for insulation monitoring in unearthed AC, AC/DC and DC power systems (IT systems) IRDH275BM-7_D00123_03_D_XXEN/01.2017 with coupling device

More information

Multi-Gas-Controller MGC2

Multi-Gas-Controller MGC2 Page 1 Aug. 2018 Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology for continuous monitoring of the ambient air to detect toxic and combustible gases, refrigerants

More information

OPTISENS TUR 2000 Technical Datasheet

OPTISENS TUR 2000 Technical Datasheet OPTISENS TUR 2000 Technical Datasheet Sensor for turbidity measurement in water and wastewater Rugged design for harsh applications Integrated transmitter with direct 4...20 ma output Near infrared light

More information

Insulation fault evaluator EDS460-DG

Insulation fault evaluator EDS460-DG Insulation fault evaluator for localising insulation faults in DC IT systems with a number of branch circuits where high system leakage capacitances are involved Preliminary data sheet TDB108021en/09.2008

More information

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM 2 Line, 16 Characters/row LCD Display Temperature Input Range -50 C to +500 C -58 F to + 932 F Enclosure NEMA Type 4X Current Rating 30A max (resistive load only) Ambient Temperature -40 C to + 40 C -40

More information

Remote alarm indicator and test combination MK2430

Remote alarm indicator and test combination MK2430 Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Tel.: 040 807-0 Fax: 040 807-259 Remote alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC

More information

ACS-30-EU-VIA-DU-20-MOD

ACS-30-EU-VIA-DU-20-MOD Multi-application heat tracing Control & Monitoring in commercial and residential buildings Surface Snow melting sensor Module Description The Raychem ACS-30-EU-VIA-DU-20-MOD Module for the ACS-30 system

More information

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) IRDH375_D00124_01_D_XXEN/07.2018 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Product

More information

Speed and Frequency Seite 1 von 7

Speed and Frequency Seite 1 von 7 Speed and Frequency Seite 1 von 7 E16 Systems for High Safety Speed ing, all with Triple Modular Redundancy. A choice of versions to meet various demands. Compliant with SIL3 / IEC 61508 and/or API 670.

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

1.7. Insulation fault evaluators EDS460/490 EDS461/491

1.7. Insulation fault evaluators EDS460/490 EDS461/491 Bender Incorporated 700 Fox Chase, Coatesville PA 1930 Tel.: (800) 356-466 Fax: (610) 383-7100 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control function

More information

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated External Dimensions: B = 600 mm D = 650 mm (at -30 C/-40 C: 760 mm) H = 1640 mm (at -30 C/-40 C: 1720mm) Internal Dimensions: B = 500 mm D = 500 mm H = 890 mm Capacity: 300 l Temperaturerange: Optional:

More information

Constant climate chambers

Constant climate chambers Constant climate chambers KBF 115 (E2) - Constant climate chamber The KBF series was particularly designed for absolutely reliable stability tests and precise maintenance of constant climatic conditions.

More information

ST Wiring diagram. Product description. Standard temperature controller. Order number

ST Wiring diagram. Product description. Standard temperature controller. Order number ST64-31.10 Standard temperature controller Order number 900197.007 Old Id.Nr.: 386169 Wiring diagram Product description The controller ST64-31.10 was developed for simple thermostatic controls. The round

More information

1.7. Insulation fault evaluators EDS460/490 EDS461/491

1.7. Insulation fault evaluators EDS460/490 EDS461/491 Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 06401 807-0 Fax: 06401 807-59 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control

More information

Capacitive leakage detectors of the Leckmaster range for installation in normally dry rooms

Capacitive leakage detectors of the Leckmaster range for installation in normally dry rooms Capacitive leakage detectors of the Leckmaster range for installation in normally dry rooms Jola Spezialschalter GmbH & Co. KG Klostergartenstr. 11 67466 Lambrecht (Germany) Tel. +49 6325 188-01 Fax +49

More information

HPLC Column Ovens and Temperature Controllers

HPLC Column Ovens and Temperature Controllers HPLC Column Ovens and Controllers Improve your separation performance today! Accurate temperature control of your HPLC columns will improve the reproducibility of your results. Operating at increased temperatures

More information

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances _D00108_00_D_XXEN/05.2015 ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances

More information

Labeling to Article 690 of the National Electrical Code Routing and Protecting PV Cables

Labeling to Article 690 of the National Electrical Code Routing and Protecting PV Cables Labeling to Article 690 of the National Electrical Code Routing and Protecting PV Cables Article 690 labeling requirements from the NEC 2011 Edition General overview of industry labeling Labeling updates

More information

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) T M 1 isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) Technical Bulletin NAE1012372 / 03.2015 isopv

More information

Power Flame Incorporated

Power Flame Incorporated Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL NVC ULTRA LOW NOx GAS BURNERS SUB 9 PPM NOx THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone: 620-421-0480,

More information

Octalarm-T: the latest in future-proof industrial alarm diallers

Octalarm-T: the latest in future-proof industrial alarm diallers Octalarm-T: the latest in future-proof industrial alarm diallers Companies are becoming increasingly reliant on computers and technical equipment. Meaning you have to take steps to guarantee continuous

More information

PolyGard 2-channel Gas Controller MGC-03

PolyGard 2-channel Gas Controller MGC-03 PolyGard 2-channel Gas Controller MGC-03 DESCRIPTION Gas measuring and monitoring controller based on state-ofthe-art micro-technology with integrated buzzer for continuous monitoring of the ambient air

More information

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges) External Dimensions: B = 1500 mm D = 820 mm H = 2100 mm Inside Dimension: Room 1 B = 600 mm D = 670 mm H = 1330 mm Room 2 B = 600 mm D = 670 mm H = 1330 mm Capacity: 1500 l Temperature range: Room 1 2

More information

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345 External Dimensions: B = 530 mm D = 640 mm H = 1600 mm Inside Dimension: Useful space on top Useful space at the bottom B = 450 mm B = 450 mm D = 535 mm D = 535 mm H = 530 mm H = 530 mm Capacity: 280 l

More information

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax: Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 505 Grünberg Tel.: 00 807-0 Fax: 00 807-259 Insulation monitoring device for unearthed AC/DC systems (IT systems for the supply of operating theatre

More information

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax: Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 505 Grünberg Tel.: 060 807-0 Fax: 060 807-59 A-ISOMETER IRDH575 Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with

More information

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING Manual Contents Introduction...3 Valve compatibility...3 Features...3 Application examples...3 Ordering...3 Operating the EKC 347...4-5

More information

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems) ISOMETER IR425 Insulation monitoring device for unearthed AC/DC control circuits (IT systems) IR425-D4_D00039_04_D_XXEN/05.2017 ISOMETER IR425 Insulation monitoring device for unearthed AC/DC control circuits

More information

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications Data Sheet Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications Ideal for small gas/oil fired boilers Cost effective solution for OEM outlets with a quick return on end-user investment Continuous

More information

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL PRODUCT Specification FEATURES Designed To Meet The Requirements Of EN54 Expandable From 1 To 5 Loops As Standard A Variety Of Networking Options

More information

Chromatographic Air circulated Refrigerator, two-door TC 603

Chromatographic Air circulated Refrigerator, two-door TC 603 External Dimensions: B = 1500 mm T = 700 mm H = 2100 mm Internal Dimensions: B = 1345 mm (clear door with: 545 mm) T = 570 mm H = 1330 mm (lower edge of evaporator) Capacity: 1000 l Temperature Range:

More information

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems) ISOSCAN EDS460/490 EDS461/491 Insulation fault locators with control and display function for EDS systems (insulation fault location systems) EDS460-490_D00085_01_D_XXEN/01.2017 ISOSCAN EDS460/490 EDS461/491

More information

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TRACON MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TABLE OF CONTENTS FPT 130 Overview... 2 Installation... 3 Power Source and Load Connections... 4 Temperature Sensor... 5 External

More information

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number ST71-KHJV.3 Temperature controller Order number 921.8 Wiring diagram Product description The switching outputs of the thermal controller can be programmed as -two-point controller with alarm -three-point

More information

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions Fan-and-filter units Features Fan-and-filter units are ideal for dissipating heat loads costeffectively. The pre-requisite is that the ambient air must be relatively clean and with a temperature below

More information

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point Medium - Control - System Franke & Haqenest GmbH Borngasse 1a * 04600 Altenburg Tel: 03447-499 313-0 Fax: 03447-499 313-6 email: info@mcs-gaswarnanlagen.de MCS User Guide MCS GasController Microprocessor

More information

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side s Frost detector for use on the air side QAF64.2-J QAF64.6-J With active capillary tube sensing element for acquiring the lowest temperature within a range of 0 15 C With startup function Operating voltage

More information

Product Manual. TZ Analog Sensors. TZ Sensors 8115CF 8116CF 8117CF 8118CF. Date: January 2015 Document Number: _B

Product Manual. TZ Analog Sensors. TZ Sensors 8115CF 8116CF 8117CF 8118CF. Date: January 2015 Document Number: _B Product Manual Date: January 2015 Document Number: 112409-01_B About TZ Telezygology, Inc. (TZ) is a wholly owned subsidiary of publicly listed intellectual property and technology development company

More information

Low Temperature Zirconia Oxygen Analyzer

Low Temperature Zirconia Oxygen Analyzer Data Sheet SS/ZDT FG Issue 10 Low Temperature Zirconia Oxygen Analyzer ZDT FG Environmental certification MCERTS SIRA certificate MC99000 1/00 User-friendly language options selectable system alarms comprehensive

More information

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm METAL SHARK COMBI Flat metal detector for textile and non-woven products Metal sensitivity from Fe 0,3 mm METAL SHARK - The new generation in metal detecting technology Introducing the METAL SHARK presenting

More information

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual We manage heat MANUAL Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents) Residual current monitor RCM470LY/RCM475LY for TN and TT systems (AC and pulsating DC currents) TDB401003en/03.2010 Residual current monitor RCM470LY Residual current monitor for TN and TT systems (AC

More information

Fire detection and alarm

Fire detection and alarm Fire detection and alarm Aesthetic Install all cabling and cable containment neatly and unobtrusively, meeting the highest electrical industry installation standards. Neatly lay and securely fix cables.

More information

LC1350 Level Controller

LC1350 Level Controller LC1350 Controller Description The Spirax Sarco LC1350 has two alarm channels that can be independently configured high or low to control the water level of a boiler, tank or vessel by operating a pump,

More information

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION Fike s CyberCat 254 (P/N 10-066) is a state-of-the-art true intelligent digital peer-to-peer modular fire alarm control system.

More information

Sensor module. Operating instructions. Sensor module, Type 17-51P2-... Document No P2-7D0001 Version: 17 May 2011/Rev. 0

Sensor module. Operating instructions. Sensor module, Type 17-51P2-... Document No P2-7D0001 Version: 17 May 2011/Rev. 0 Sensor module Operating instructions Sensor module, Document No. 11-51P2-7D0001 Version: 17 May 2011/Rev. 0 Operating Instructions Sensor-Module Type: 17-51P2-. Document no.: 11-51P2-7D0001 Version: 17.

More information

Constant climate chambers

Constant climate chambers KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.

More information

Advantages / Characteristics

Advantages / Characteristics Air to Air 50 W 30 W cooling capacity 163x104x144mm (LxBxH) 1,9 kg Air to Air 70 W 36 W cooling capacity 163x104x144mm (LxBxH) 1,9 kg Air to Air 75 W 30 W cooling capacity 130x109x163mm (LxBxH) 1,5 kg

More information

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440) Safety Temperature Limiter STL 50 Certified to DIN EN 14597 (replaces DIN 3440) Features M For use as: STB Protection - temperature limiter ASTB Exhaust gas - protection - temperature limiter STW Protection

More information

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. L Type Anchor Bolt Carbon Steel AISI 304 S.S. ANCHOR BOLT DETAIL Heavy Flat Washer Heavy Hex Nut UNC Th'd Mounting Flange Of Equipment To Be Mounted C B A D Non-Shrink Grout. Poured In Place, After Equipment Setting. Heavy Flat Washer Heavy Hex Nut

More information

A. Product Data: For each electrical identification product indicated. B. Comply with 29 CFR and 29 CFR

A. Product Data: For each electrical identification product indicated. B. Comply with 29 CFR and 29 CFR September 2012, rev. 00 26 0553 Identification for Electrical Systems PART 1. GENERAL 1.01 Summary A. Section Includes: 1.02 Submittals 1. Identification for raceways. 2. Identification of power and control

More information

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply   - Tel: Systems Index Systems - Systems Systems...1 -.16 General information Description...1 System description...2 Overview...3 Ordering details Arc monitor with detectors...4 Current sensing unit...5 Technical

More information

RTD TEMPERATURE SENSING SYSTEM

RTD TEMPERATURE SENSING SYSTEM General Overview RTD TEMPERATURE SENSING SYSTEM The Prime Technology RTD Temperature System 9219-00-0002 is a three-channel temperature measuring system that utilizes two RTD Temperature Sensor inputs

More information

LEAKSTOPPER RANGE Multizone water leak detection systems

LEAKSTOPPER RANGE Multizone water leak detection systems LEAKSTOPPER RANGE Multizone water leak detection systems WHAT DOES THE PRODUCT DO? The LeakStopper detects water leaks and instantly triggers an alarm to warn you. It is capable of monitoring between 2

More information

Ionisation single-tube smoke detector for duct mounting

Ionisation single-tube smoke detector for duct mounting Detectors Ionisation single-tube smoke detector for duct mounting 600 mm venturi tube is included., incl. end resistor (not RAC(M)) 9...33 V DC (via ABV control unit). 24 V AC ±15 % for RAC(M) models.

More information

Monitoring Devices 11/1

Monitoring Devices 11/1 11/4 Introduction 11/6 5TE5 8 light indicators 11/7 4AC3 0, 4AC3 1 bells, buzzers 11/7 5TT3 46 fault signaling units 11/8 7LQ2 1, 5TT3 3 dusk switches 11/9 7LQ2 0 temperature controllers 11/9 5TT3 170

More information

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment: Constant climate chambers KBF 240 (E5.2) - Constant climate chamber The KBF series was particularly designed for absolutely reliable stability tests and precise maintenance of constant climatic conditions.

More information

TM800. Remote alarm indicator and operator panels

TM800. Remote alarm indicator and operator panels TM800 Remote alarm indicator and operator panels TM800_D00165_00_D_XXEN/12.2014 TM800 Remote alarm indicator and operator panels TM800 Device features Display, control and operation of Bender monitoring

More information

Technical Manual. Level Alarm Unit CARLA & WIDS

Technical Manual. Level Alarm Unit CARLA & WIDS CARLA & WIDS Technical Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Technical Manual CARLA for Tankers Cargo Tanks

More information

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi 50 (P/N 10-071) is a state-of-the-art true intelligent digital peer-to-peer modular suppression control system.

More information

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor Labkotec UK Ltd Adminicle House 1 Lumb Lane Audenshaw Manchester M34 5WH GREAT BRITAIN Tel: 0844 3350 477 Fax: 0161 4281 179 E-mail: info@labkotec.co.uk 10.8.2012 Internet: www.labkotec.co.uk 1/13 OilSET-1000

More information

Fire control panel detect 3004 plus and accessories

Fire control panel detect 3004 plus and accessories Fire control panel detect 3004 and accessories The modular fire alarm panel detect 3004 is the basic version of a broad product portfolio of the system detect 3000. Up to 20 fire control panels can be

More information

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Plasma Freezer with air circulation TC 516 acc. to DIN 58375 These blood plasma storage cabinets are designed for DIN - compliant storage of already frozen blood plasma bags. External Dimensions: B = 600 mm D = 780 mm H = 2000 mm Internal Dimensions: B = 500 mm

More information

Refrigerated Incubator Model and Operating Instructions

Refrigerated Incubator Model and Operating Instructions Refrigerated Incubator Model 165000 and 165000-2 Operating Instructions N2400379 - Rev. 1 08May2018 1 Contents 1. SAFETY...3 1.1. EMF INTERFERENCE...4 1. PRODUCT INFORMATION...5 1.1 INTRODUCTION...5 2.

More information

PRODUCT LINE. Highest Quality, Best Service

PRODUCT LINE. Highest Quality, Best Service PRODUCT LINE Highest Quality, Best Service Manufacturing chlorination equipment and related products since 1978 PROUDLY MADE IN USA 600 Emlen Way, Telford, PA 18969 Telephone: (215) 799-0980 Fax: (215)

More information

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM Card Rack Modules CABLE DUCT MAIN SWITCH 800 mm USER INTERFACE TERMINAL PRODUCT OVERVIEW The nvent

More information

Colour Observation System

Colour Observation System FAR < > NEAR Colour Observation system talk action menu _ + auto next FAR < > NEAR Colour Observation Monitor Colour Observation Monitor English Colour Observation System Table of contents Page Introduction...3

More information

Instructions for the BASIC BCRW Fan, Sizes General

Instructions for the BASIC BCRW Fan, Sizes General Instructions for the BASIC BCRW Fan, Sizes 004 027 1. General The BCRW is a direct-driven fan of axi-centrifugal design. This fan offers excellent power efficiency, low, uniform air flow, low sound generation

More information

SECTION ELECTRICAL IDENTIFICATION

SECTION ELECTRICAL IDENTIFICATION SECTION 16075 - ELECTRICAL IDENTIFICATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

PANTHER. Condensate removal pump Installation and operating guide

PANTHER. Condensate removal pump Installation and operating guide PANTHER Condensate removal pump Installation and operating guide The PANTHER is a self-contained condensate removal system for use directly inside trunking and highwall-mount air conditioners.the small

More information

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en Technical information TI074R/09/en 51001353 Contactor RTA421 Contactor with loop power supply for monitoring currentorvoltagesignals Application areas Plant and machine construction Panel builders Process

More information

UV - Monitor UVT 16. Use. Description

UV - Monitor UVT 16. Use. Description UV - Monitor UVT 16 Use The UVT 16 Monitor is used to monitor signals from UV probes or sensors applied to sources of radiation, providing a control system for small items of UV equipment. Description

More information

NXM2G Installation and Operating Manual

NXM2G Installation and Operating Manual NXM2G-1001 MARCH 26, 2014 NXM2G Installation and Operating Manual (-1 UL version shown) 40VG This manual must be affixed on or adjacent to the boiler or kept with boiler operating manual or other information.

More information

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor... Improve Performance and Reduce Maintenance Costs Model Q45D Dissolved Oxygen Monitor... Why Throw Away Money? Why Throw Away Money? ATI s Model Q45D Dissolved Oxygen monitor is designed to provide reliable

More information

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER MODEL AL3 7 5 - AL3000 series conforming to CE, UL and CSA are 100mm multi-point type hybrid recorders with a simultaneous display of multi-channel

More information

laboratory & sterilization technology

laboratory & sterilization technology laboratory & sterilization technology BM SERIES Circulated Water Baths Designed for many general and special applications in microbiology, research and industrial laboratories Powerful circulation by means

More information

THERMAL MANAGEMENT THERMAL MANAGEMENT. Accessories: GV 400/500 or GV 600/700 AM 420P TRS 60, TRW 60, TWR 60, TKW 60 FILTER FANS SERIES LV

THERMAL MANAGEMENT THERMAL MANAGEMENT. Accessories: GV 400/500 or GV 600/700 AM 420P TRS 60, TRW 60, TWR 60, TKW 60 FILTER FANS SERIES LV FILTER FANS SERIES LV ROOF MOUNTED FAN For the ventilation of control cabinets, enclosures and housings Different filter mats for dust collection LV series offers low shape and quick mounting EMC versions

More information

Industrial Strength Leak Detection

Industrial Strength Leak Detection Industrial Strength Leak Detection Don t let an undetected leak or spill ruin the environment or your reputation... TraceTek Technology: Find leaks before major damage is done... TraceTek Technology: Sensor

More information

On the job around the clock 24/7: Fire detection systems

On the job around the clock 24/7: Fire detection systems On the job around the clock 24/7: Fire detection systems Version 02.2010 Version: 02.2010 Product catalogue Fire detection systems This product catalogue is intended for sales purposes only. For planning,

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

Krypton K CL2. Measuring and control system for free chlorine. applications. description. Low maintenance by automatic sensor cleaning

Krypton K CL2. Measuring and control system for free chlorine. applications. description. Low maintenance by automatic sensor cleaning Low maintenance by automatic sensor cleaning Pressure-proof up to 6 bar at 20 C Higher safety by integrated flow monitoring applications Drinking Water / Beverages Food Industry Disinfection Cooling And

More information

Capacitive leakage detectors of the Leckmaster range for installation in normally dry rooms

Capacitive leakage detectors of the Leckmaster range for installation in normally dry rooms Capacitive leakage detectors of the Leckmaster range for installation in normally dry rooms Jola Spezialschalter K. Mattil & Co. KG Klostergartenstraße 11-20 D-67466 Lambrecht (Pfalz) P.O.B. 1149 D-67460

More information

HYGROPHIL H process hygrometer

HYGROPHIL H process hygrometer HYGROPHIL H 4230-10 process hygrometer Continuous humidity measurement in industrial processes. For very high demands in terms of being resistant to corrosion and dirt. Particularly suitable for cases

More information

Deep Freezers. Freezers. Biomedical Refrigeration I FR / MF

Deep Freezers. Freezers. Biomedical Refrigeration I FR / MF Deep Freezers and Plasma Storage Freezers Biomedical Refrigeration I FR / MF Low-temperature storage of plasma and other blood products at 41 C/ 35 C According to DIN 58375 www.dometic.lu Deep Freezers

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Wed : www.saenchotesei.com WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 920 - Wall, 19 Rack or Panel Mounting Units - 110/230V 50/60Hz AC operation - 250 Addressable

More information

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement Data sheet High Temperature Zirconia Oxygen Analyzer Superior technology and quality from the world leader in oxygen measurement User-friendly language options selectable system analysis comprehensive

More information

DEEP FREEZERS AND PLASMA STORAGE FREEZERS. Biomedical Refrigeration I FR / MF TECHNOLOGY FOR LIFE

DEEP FREEZERS AND PLASMA STORAGE FREEZERS. Biomedical Refrigeration I FR / MF TECHNOLOGY FOR LIFE TECHNOLOGY FOR LIFE DEEP FREEZERS AND PLASMA STORAGE FREEZERS Biomedical Refrigeration I FR / MF Low-temperature storage of plasma and other blood products at 41 C/ 35 C According to DIN 58375 www.dometic.lu

More information

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX Page 1 of 10 Model 10807800 January 2014 ACCURATE ELECTRONICS INC PO BOX 1654 97075-1654 8687 SW HALL BLVD 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 WWW.ACCURATE.ORG Practice Section 10807800

More information

ACCURATE ELECTRONICS INC

ACCURATE ELECTRONICS INC ACCURATE ELECTRONICS INC Page 1 of 7 Model 108078 2 Sept 09 WWW.ACCURATE.ORG PO BOX 1654 97075-1654 8687 SW Hall Blvd 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 Practice Section 108078 Rev A

More information

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173) Evco S.p.A. Code 104K204E05 page 1/5 EVK204 Digital controller for ventilated refrigerating units, with HACCP and Energy Saving functions version 1.05 GB ENGLISH 1 PREPARATIONS 1.1 Important Please read

More information

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor

More information

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi (P/N 10-068) is a state-of-the-art true intelligent digital peer-topeer modular suppression control system. It is ideal for

More information

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems) Insulation monitoring device for unearthed AC/DC control circuits (IT systems) TDB103005en/05.2013 Insulation monitoring device for unearthed AC/DC control circuits (IT systems) Product description The

More information