G-TECTA Cellaguard Carbon Dioxide and Oxygen Fixed Monitors
|
|
- Alban Knight
- 5 years ago
- Views:
Transcription
1 G-TECTA Cellaguard Carbon Dioxide and Oxygen Fixed Monitors EN Operating Manual
2 2 3 Contents Safety and Warning information 2 Introduction 3 Operation & Set Up 3 Cellaguard Features 3 Initial Set Up 4 Carbon Dioxide Warning Labels 4 LED Status 5 Alarm Conditions 5 Self Test 6 Gas Testing 6 Cellaguard Options 7 Product Specification 8 Troubleshooting 8 Declaration of Conformity 9 Warranty 10 Whilst The Linde Group has made every effort to ensure that the details and information given in both our printed and online publications are accurate at the time of issue, full technical specifications are not necessarily included. Furthermore The Linde Group policy is one of continuous improvement and the right is reserved to alter details and information as the need arises. Accordingly the Customer should check any details and information they wish to rely on with The Linde Group at the time of purchase. The Linde Group can not accept liability in respect of any errors or omissions herein contained or for any loss or damage malfunction or consequential loss arising from reliance upon our publication. The customer will be responsible for any risk to health or safety from goods in the Customer s possession and/ or control. The Customer s attention is drawn to the fact that statutory regulations and recognised codes of practice exist covering the use and handling of some goods (including safety products.) The Customer must ensure that persons who use the goods receive adequate training and safety literature. Safety and Warning information WA R N I N G Read and understand all instructions in the operation sections of this manual before use. WA R N I N G Do not substitute components. WA R N I N G Observe all warnings and instructions marked on the unit and within this operating manual. WA R N I N G Observe site health and safety procedures for gases being monitored and evacuation procedures. WA R N I N G Make sure you understand the alarm warnings. WA R N I N G If this product is not working properly, read the operating manual or call The Linde Group. WA R N I N G The accuracy of G-TECTA Cellaguard instruments should be checked periodically with known concentration calibration gas. Failure to check accuracy can lead to inaccurate and potentially dangerous readings. WA R N I N G Ensure maintenance and calibrations are carried out in accordance with the procedures in the installation & maintenance manual. WA R N I N G Ensure only qualified service personnel change sensors and batteries. Introduction G-TECTA Cellaguard is a carbon dioxide (CO 2 ) or a carbon dioxide and oxygen (O 2 ) fixed monitoring system, designed to monitor gas levels in a confined space such as a beer cellar. The Cellaguard system consists of a wall mounted base station, housing the gas monitoring system, and is normally supplied with one repeater unit to be located in a safe position outside the confined space area. There are two main versions of the G-TECTA Cellaguard ; Version 1 is a carbon dioxide monitor only, which looks for rising CO 2 gas levels in the confined space; Version 2 is a combined sensor system which monitors both rising levels of carbon dioxide and falling levels of oxygen. G-TECTA Cellaguard features two alarm relays, which can control external visual or audible alarms or ancillary equipment such as a ventilation fan. The Cellaguard system is simple to install using a mains power supply and has been designed for one-man installation. The alarm levels are factory set and the relays are fail-safe to ensure the alarms will activate if the power supply fails. The G-TECTA Cellaguard is normally supplied with one repeater unit. The repeater unit mimics the alarms, fault alarm, power indicator, mode button and sounder on the base unit. A series of up to 4 repeater units can be connected together at distances of up to nine metres per repeater. This allows the user to position the alarm system warnings in visible and convenient locations. Operation & Setup G-TECTA Cellaguard Base Station Features Power Fault LED Mains Power Display G-TECTA Cellaguard CO 2 Base Station Note: The CO 2 & O 2 version of G-TECTA Cellaguard will have two sensor positions The base station houses the gas sensors, a display, a mode button, four illuminating LEDs and a sounder. There are electrical connections for mains power, two relay outputs and the repeater unit at the bottom of the base station. A 2 metre mains cable and two carbon dioxide warning labels are also provided. G-TECTA Cellaguard Repeater Features The repeater has a mode button, four illuminating LEDs and a sounder. The repeater mimics the output of the base station and is supplied with a 9 metre connection cable. High Alarm Low Alarm Sounder Mode Button Fault Power LED Sounder G-TECTA Cellaguard Repeater Mode Button Low Alarm LED High Alarm LED CO 2 Sensor
3 4 5 Mode Button: The mode button is located on both the base station and the repeater and is used to communicate with Cellaguard. The mode button is used for the display backlight function, the monitor self-test procedure and to silence the sounder in the event of an alarm or fault occurring. Base Station Display The Cellaguard base station display shows the actual gas levels being monitored. Carbon dioxide (CO 2 ) is shown as a percentage value and in normal environments (safe level) will display 0 to 0.2%. G-TECTA Cellaguard monitors with the oxygen sensor option will display alternate readings of CO 2 and O 2. Normal oxygen gas level concentration is 20.9%. Display Backlight The display backlight is activated by quickly pressing the mode button. G-TECTA Cellaguard Initial Setup The Cellaguard is designed to work out of the box and requires no configuration of the gas sensors or alarm settings. Once the Cellaguard base station and repeater unit(s) are installed, you can switch on the mains supply. The Cellaguard system will become fully operational after a 40-second warm-up period. Note: The LED alarms and sounder will operate momentarily during this period and the display will self-test. WA R N I N G Carbon dioxide warning labels The Cellaguard is supplied with two carbon dioxide warning labels. Carbon Dioxide can cause asphyxiation in low concentrations and it is important to affix the labels at eye level and in a prominent position at the entrance to the confined space being monitored (normally next to the repeater). Write the name and contact details (in the box provided) of the person responsible for the confined space to contact in the event of an alarm. CO 2 RISK OF DEATH DO NOT ENTER if: The yellow fault LED is on The red alarm LED is on The green power LED is off If the alarm sounds and LED warning lights activate whilst in the area, LEAVE IMMEDIATELY For advice on alarms contact: G-TECTA CELLAGUARD Normal and fault states of LEDs The LEDs on the base station and repeaters indicate conditions as shown in the table below: LED Function Operation Indication Power Fault Low Alarm High Alarm (Green LED) (Yellow LED) (Red LED)* (Red LED)* Normal operation Not operating Fault condition Power failure System fault Low (pre-alarm) alarm level exceeded High (main) alarm level exceeded Gas Levels LED Indication Sounder Indication Relay Indication Normal No alarm LEDs No sound Not active Carbon Dioxide Alarms Low alarm activates Low alarm LEDs flashing Long beep once per second Pre-alarm relay connection active High alarm activates Low and high alarm LEDs flashing Long beep once per second Pre-alarm and main alarm relay connections active Oxygen Alarms Low alarm activates Low alarm LEDs flashing Long beep once per second followed by one short beep Pre-alarm relay connection active High alarm activates Low and high alarm LEDs flashing Long beep once per second followed by one short beep Note: CO 2 alarms may be subject to a 25 second time delay to prevent false alarms when exchanging gas cylinders. Oxygen alarms are instantaneous. When the gas level(s) have returned to normal, the alarm LEDs will automatically extinguish and the Cellaguard will return to normal operating mode. LED extinguished LED on continuously Sounder beeps every 20 seconds G-TECTA Cellaguard Alarm conditions for Base Station and Repeaters When the alarm gas level is exceeded the sounder and alarm LEDs will operate as below: Pre-alarm and main alarm relay connections active Note: The sounder and illuminating LEDs will reactivate if the alarm level(s) are exceeded again.
4 6 7 G-TECTA Cellaguard Fault Alarm The system fault alarm will activate if a sensor fault condition occurs. If the system fault alarm is activated the G-TECTA Cellaguard will beep twice every second and the yellow warning LED will flash. Note: If the fault alarm activates, please contact The Linde Group to arrange for a replacement sensor to be fitted. G-TECTA Cellaguard Mode Button (Alarm function) The mode button is used to communicate with the Cellaguard system after an alarm has been triggered. Press and hold the mode button for 5 seconds to silence the Cellaguard alarm sounder. The alarm LEDs will continue to flash in an alarm condition (i.e. CO 2 gas is still present or there are low levels of oxygen). WA R N I N G In the event of an alarm condition, DO NOT ENTER THE ROOM. Contact the person responsible for the confined space area. Carbon Dioxide and Oxygen deficiency can cause instant death. Note: Electrical connections for the optional external alarm equipment are located inside the Cellaguard base station -one connection terminal is provided for the main alarm and one for the pre alarm. G-TECTA Cellaguard Self-Test A self-test routine is provided to test the Cellaguard and any ancillary equipment attached via the alarm relays. To run the self-test routine, press and hold the mode button for 5 seconds. The self-test can be initiated from the base station or any of the repeater units. The base station display will illuminate and test all display segments and the Cellaguard will alarm for a period of 10 seconds; illuminating the alarm LEDS, activating the sounder, and activating any additional ancillary alarm equipment connected to the Cellaguard relays. Gas Testing Functional Testing G-TECTA Cellaguard monitors should be functionally tested, as a minimum, every 12 months to ensure that the sensors and alarms are operational. Carbon Dioxide (CO 2 ) Cellaguard Monitors Periodic testing may be performed simply by using exhaled breath to generate high CO 2 alarms. Exhaled breath contains approximately 4% CO 2, and therefore contains sufficient levels of CO 2 gas to cause alarms on the Cellaguard monitor. CO 2 sensors have a life expectancy of more than 5 years in normal operating environments. Carbon Dioxide (CO 2 ) and Oxygen (O 2 ) Cellaguard Monitors Periodic testing of both sensors may be performed simply by using exhaled breath to generate high CO 2 and low oxygen alarms. Exhaled breath contains approximately 4% CO 2 and 16% oxygen, and therefore contains sufficient levels of each gas to cause alarms on the Cellaguard monitor. The Oxygen sensor must be replaced every 3 years. Note: The Linde Group also recommends full recalibration after 3 years of use. G-TECTA Cellaguard Functional Testing Process 1. Find a suitable plastic bag 2. Inflate the plastic bag by blowing gently into it 3. Hold the open end of the inflated bag tightly over the sensor(s) and wait until the alarms activate. 4. The Cellaguard display will show increased levels of CO 2 and decreased levels of oxygen (if fitted). The O 2 alarm (if fitted) will activate instantly and the CO 2 alarm after approximately 25 seconds. G-TECTA Cellaguard Options Battery Backup The Cellaguard can be fitted with an optional battery, providing 2 hours of power backup in the event of mains power failure. When in backup mode the Cellaguard will beep every 20 seconds. Additional repeater units Up to 4 repeater units can be connected to the Cellaguard base station. Each repeater is supplied with a 9m cable. G-TECTA Cellaguard Calibration Unit The Cellaguard Calibration Unit allows the service engineer to calibrate the sensors in the Cellaguard monitor. The Linde Group recommends calibration every 3 years to ensure correct operation of the Cellaguard monitor. Note: Sensor re-calibration is typically offered as an after sales service for the Cellaguard monitor please contact The Linde Group for further details
5 8 9 G-TECTA Cellaguard Product Specification Base Unit Dimensions 210 x 150 x 75 mm Weight 1.3 Kg IP Rating (Dusts & Liquids) IP65 Operating Temperature Rating +3 C to +50 C (+37 F to +122 F) Operating Voltage 230Vac (115Vac), 50/60Hz, 16VA, double insulated Humidity Rating 0-95% RH Display Backlit LCD 13.5mm high digits Warm-up time period 40 seconds Instrument Status Indicators Red LEDs Gas level alarms Yellow LED Fault alarm Green LED Power Indicator Alarm sounder Cable Length 2m Fixing Centres 192mm x 72.5mm (Quantity 4) Relay Outputs SPCO 10A, 240Vac / 30Vdc Repeater Dimensions 143 x 56 x 41 mm Weight 120g IP Rating (Dusts & Liquids) IP54 Operating Temperature Rating 0 C to +50 C (+32 F to +122 F) Instrument Status Indicators Red LEDs Gas level alarms Yellow LED Fault alarm Green LED Power Indicator Alarm sounder Cable Length 9m Fixing Centres 130mm (Quantity 2) G-TECTA Cellaguard Troubleshooting LED Function Operation Indication Power LED off Power LED on continuously Fault LED is lit and sounder is emitting continuous beeps Display showing an error Power not reaching the monitor processor Monitor processor not working correctly Sensor fault Base station has been opened for service or wiring with battery backup option installed Check base station is plugged in and the electrical supply is connected and switched on. Check main fuse. Monitor requires repair contact The Linde Group Monitor requires new sensor contact The Linde Group Wait for 40 second warm-up period. If the error continues contact The Linde Group If you experience any other issues with the operation of the G-TECTA Cellaguard instrument, please go to or contact an Authorised Linde Group Service Centre. Declaration of Conformity In accordance with ISO/IEC :2004 We hereby declare that on the date the products accompanied by this declaration are placed on the market, the products conform with all technical and regulatory requirements of the directives listed below. Product Type G-TECTA Cellaguard Product Description Carbon Dioxide and Oxygen Fixed Gas Detection Monitor Applicable Directives Electromagnetic Compatibility 2004/108/EC Conformity Harmonised Standards EN50270:2006; EN :2007 Conformity Other Standards FCC CFR 47: Part 15.B: 2007 Signed: Name: Peter Upcott Company: The Linde Group, GU2 7XY, UK Position: Global Category Manager Safety Products Date: June 2010
6 10 11 The Linde Group Instrumentation Warranty Gas Detection Products General The Linde Group warrants gas detectors, sensors and accessories manufactured and sold by The Linde Group to be free from defects in materials and workmanship for the periods listed in the tables below. Damages to any Linde Group products that result from abuse, alteration, power fluctuations including surges and lightning strikes, incorrect voltage settings, incorrect batteries, or repair procedures not made in accordance with the product s Operating Manual, are not covered by The Linde Group warranty. The obligation of The Linde Group under this warranty is limited to the repair or replacement of components deemed by The Linde Group Service Department to have been defective under the scope of this standard warranty. To receive consideration for warranty repair or replacement procedures, products must be returned with transportation and shipping charges prepaid to The Linde Group, or to a Linde Group Authorised Warranty Service Centre. It is necessary to obtain a return authorisation number from The Linde Group prior to shipment. THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY AND ALL OTHER WARRANTIES AND REPRESENTATIONS, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO, THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. THE LINDE GROUP WILL NOT BE LIABLE FOR LOSS OR DAMAGE OF ANY KIND CONNECTED TO THE USE OF ITS PRODUCTS OR FAILURE OF ITS PRODUCTS TO FUNCTION OR OPERATE PROPERLY. Warranty Periods for Instruments and Accessories Product G-TECTA Cellaguard Battery packs and consumables Warranty Periods for Sensors Sensor type Oxygen CO 2 Warranty period 1 year from date of purchase 1 year from date of purchase Warranty period 1 year 1 year Notes
7 Australia BOC Customer Service Centre 10 Julius Avenue, North Ryde, Sydney NSW 2113 Australia Tel: Fax: New Zealand BOC Customer Service Centre 988 Great South Road, Penrose, Auckland New Zealand Tel: Fax: UK BOC Customer Service Centre Priestley Road, Worsley, Manchester, M28 2UT United Kingdom Tel: Republic of Ireland: Fax: or South Africa Afrox Customer Service Centre 1 Smits Street, Industries West, Germiston 1400 South Africa Tel: Fax: customer.service@afrox.linde.com Canada Linde Customer Service Centre 5860 Chedworth Way, Mississauga, Ontario, L5R OA2 Canada Tel: Fax: info@lindecanada.com Colombia AGA Customer Service Centre Apartado Aéreo 3624 Bogotá D.C. Colombia Tel: +57/1/ Fax: +57/1/ atencionaclientes@co.aga.com Thailand TIG Customer Service Centre 15th Floor, Bangna Tower A 2/3 Moo 14, Bangna-Trad Road., T.Bangkaew, A.Bangplee, Samutprakarn 10540, Thailand Tel. (66-2) Fax. (66-2) Customer Service Centre : salescenter@tig.boc.com V G-TECTA Cellaguard Operating Manual 2010 The Linde Group. All rights reserved. No page or part of this operation manual may be reproduced in any form without written permission of the copyright owner shown above. The Linde Group reserves the right to correct typographical errors. All information is correct at time of going to print. The Linde Group: Linde, BOC, AGA, Afrox
G-TECTA Cellaguard Carbon Dioxide and Oxygen Fixed Monitors
G-TECTA Cellaguard Carbon Dioxide and Oxygen Fixed Monitors UK Installation & Calibration Manual 2 Contents Safety and Warning information 2 Installation 2 Mounting 3 Cabling Requirements 4 External Alarm
More informationCellarSafe. Carbon Dioxide and Oxygen Safety Monitor
CellarSafe Carbon Dioxide and Oxygen Safety Monitor Installation and operating instructions for the CellarSafe Monitor and the CellarSafe Calibration Unit M07234 May 2008 Issue 6 Warning Please take care
More informationG TECTA 4G Multi-Gas Detection Instrument
G TECTA 4G Multi-Gas Detection Instrument EN Operating Manual 2 3 Contents Safety and Warning information 3 Instructions specific for use in hazardous areas 3 Instructions specific for use in non-hazardous
More informationModel Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:
Model 2102 Gas Alarm Panel APPLICABILITY & EFFECTIVITY This manual provides instructions for the following Sierra Monitor products: Model Description 2102-00 Alarm Panel 2 Channel 2102-01 Alarm Panel 2
More informationENMET Corporation. PO Box 979 Ann Arbor, MI RECON. Manual. Manual Part Number MCN-410, 12/03/08
PO Box 979 Ann Arbor, MI 48106-0979 RECON Manual Manual Part Number 80006-018 MCN-410, 12/03/08 Table of Contents 1.0 INTRODUCTION... 1 1.1 UNPACK... 1 1.2 CHECK ORDER... 1 1.3 SERIAL NUMBERS... 1 2.0
More informationModel TL104 MANTL104. Test Lamp for Flame Detection
Model TL104 Test Lamp for Flame Detection The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing
More informationBeacon 800 Gas Monitor Operator s Manual
Beacon 800 Gas Monitor Operator s Manual Part Number: 71-0037RK Revision: F Released: 4/18/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by us to be
More informationAFA 500 FUME HOOD ALARMS
AFA 500 FUME HOOD ALARMS Operating and Instruction Manual 19/7/03 Model AFA 500 Built-in or Remote sensor 2 Relay inputs 1 Relay output Com port Used for alarm indication and monitoring on Fume Cupboards
More informationUSER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -
USER GUIDE DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER - II CONTENTS 1. SYMBOLS AND WARNINGS... 5 2. GENERAL INFORMATION... 6 3. WARNINGS... 7 4. GENERAL DESCRIPTION... 8 5. INSTALLATION...
More informationUSER MANUAL Digital CO Monitor Model CO30
USER MANUAL Digital CO Monitor Model CO30 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech Instruments Model CO30. The CO30 is a 3 in one
More informationRK/ RK Oxygen Detector Operator s Manual
65-2502RK/65-2510RK Oxygen Detector Operator s Manual Part Number: 71-0074RK Revision: A Released: 3/1/11 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating detector.
More informationMacurco HD-11 Hydrogen Gas Detector
Macurco HD-11 Hydrogen Gas Detector User Instructions Important: Keep these User Instructions for reference TABLE OF CONTENTS GENERAL SAFETY INFORMATION 3 Intended Use 3 List of Warnings and Cautions 3
More informationG-TECTA TM. Portable Gas Detection Instruments
G-TECTA TM Portable Gas Detection Instruments 2 Why Linde gas detection? The Linde Group is a global leader in the supply of gases, we provide expertise and product solutions to industry, commerce, science
More informationBuzzer Unit. TAN-5000 Series. Operating Manual
PT1E-1040 Buzzer Unit TAN-5000 Series Operating Manual Request for the Customers Read and understand this operating manual before using the buzzer unit. Use the buzzer unit in accordance with the operating
More informationMatrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1
Matrix2000 User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 s Version: 2.0 Revision: 1 IMPORTANT INFORMATION Limitation of liability It is mandatory, Matrix2000 panel to be installed in accordance
More informationM3050 Detector Operator s Manual
FABRICON SYSTEMS ALBERTA 2008 INC. Keeping you in Front M3050 Detector Operator s Manual Telephone: (403)652-2127 Mailing Address: Shipping Address: Fax: (403)652-3027 Box 5996 402 Ellis Crescent S.E Email:
More informationVA301C CONTROLLER WITH BACnet OPTION
ORDERING INFORMATION VA301C Controller VA301C-DLC VA301C-DLC-BIP Gas detection controller with data logging, display and plastic housing. Gas detection controller with data logging and display, BACnet/IP
More informationGG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual
GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL Installation and Operation Manual 2 GG-2 Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified
More informationGASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL
GASGUARDIAN 2 3 2-Channel Controller OPERATING & INSTALLATION MANUAL GasGuardian 2 3 Operating and Installation Manual Table of Contents General description.... 3 Installation. 3 Locating the GasGuardian-2..
More informationC-Bus Black & White MK II Touch Screen. 5000CT2 Series. User s Guide
C-Bus Black & White MK II Touch Screen 5000CT2 Series Clipsal is a registered trademark of Clipsal Australia Pty Ltd ABN 27 007 873 529. Neo is a registered Trademark of Clipsal Australia Pty Ltd. Copyright
More informationMacurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference
Macurco HD-11 Hydrogen Gas Detector User Instructions Important: Keep these User Instructions for reference 2 TABLE OF CONTENTS GENERAL SAFETY INFORMATION 4 INTENDED USE 4 LIST OF WARNINGS AND CAUTIONS
More information3500 CONVENTIONAL FIRE ALARM CONTROL PANEL
3500 CONVENTIONAL FIRE ALARM CONTROL PANEL USER MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273 Web:
More informationWarranty Registration
WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free from defects in workmanship and materials for a period
More informationUBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1
U S E R M A N U A L UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1 0359 18 UBS1RF Optical Smoke Alarm OverView This optical smoke alarm is a fire detection and alarm device which gives
More informationRK / RK CO 2 Detector Operator s Manual
61-1004RK / 61-0191RK CO 2 Detector Operator s Manual Part Number: 71-0145RK Revision: C Released: 10/29/18 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating detector.
More informationCA5000 Liquid CO 2 Freezer Backup System
CA5000 Liquid CO 2 Freezer Backup System OPERATING INSTRUCTIONS MANUAL HAMPSHIRE CONTROLS CORPORATION ONE GROVE STREET / P.O. BOX 516, DOVER, NEW HAMPSHIRE USA 03821 TEL. (603) 749-9424 FAX (603) 749-9433
More informationDoor Release Power Supply
www.protectingpeople.co.uk Door Release Power Supply Engineer / Installation Manual Document: VI55.1 Protecting People Printed : 04/03/2004-1 - Ventcroft Ltd Door Release Power Supply Engineer / Installation
More informationCD6102 / CD6102 OC / CD6102-2
PreView Display CD6102 / CD6102 OC / CD6102-2 Operating Manual www.previewradar.com PATENTS Patented under one or more of the following U.S. Patents: 5345471, 5523760, 5457394, 5465094, 5512834, 5521600,
More information1022 R/T Remote Monitor
1022 R/T Remote Monitor INSTRUCTIONS AMC-1022R/T WITH REMOTE SENSOR OR TRANSMITTER INSTALLATION AND OPERATING INSTRUCTIONS FOR THE AMC-1022R/T UNIT IMPORTANT: Please read these installation and operating
More informationGasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08
GasScanner 8C Eight Channel Monitor Operator s Manual MINT-0281-XX Rev. A 01/29/08 Product Warranty Matheson Tri-Gas, Inc., warrants gas alarm equipment sold by us to be free from defects in materials,
More informationGG-EM ENTRANCE MONITOR. Installation and Operation Manual
GG-EM ENTRANCE MONITOR Installation and Operation Manual 2 GG-EM Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration
More informationProtégé Eclipse LED Keypad User Manual PRT-KLES
Protégé Eclipse LED Keypad User Manual PRT-KLES The specifications and descriptions of products and services contained in this manual were correct at the time of printing. Integrated Control Technology
More informationRK/ RK Oxygen Detector Operator s Manual
65-2494RK/65-2497RK Oxygen Detector Operator s Manual Part Number: 71-0179RK Revision: 0 Released: 2/16/11 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating detector.
More informationKM300 Carbon Monoxide Detection System Installation Manual
GE Security KM300 Carbon Monoxide Detection System Installation Manual P/N 1068922 REV 2.0 16SEP09 Copyright Copyright 2009 GE Security, Inc. All rights reserved. This document may not be copied in whole
More information10yr O2NE & Safe-Ox. User Manual
Analox Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK T: +44 (0)1642 711400 F: +44 (0)1642 713900 W: www.analox.net E: info@analox.net This support line is closed on UK public
More informationInstruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail
Manufacturers of Process Controls and Instrumentation Instruction Manual Model: Function: Input: PCS-400-XY Pump Controller X=2: 4-20 ma X=5: 1-5 VDC X=6: 0-10 VDC X=7: Output: Power: 4 Pump Control Relays
More informationOperation and Maintenance Manual
(FKER Series) Repeater Panel (FKER, FKER, FKER8) Operation and Maintenance Manual Man-9EL Issue June Index Section Page. Introduction.... Safety and mounting.... Technical specification.... Control panel
More informationRK CO 2 Transmitter Operator s Manual
65-2397RK CO 2 Transmitter Operator s Manual Part Number: 71-0185RK Revision: B Released: 7/18/14 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual before
More informationThermometer with Probe model 00891A
Instruction Manual Thermometer with Probe model 00891A CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2 Features & Benefits... 3 Setup... 4 Temperature Units... 4 Placement
More informationOPEARATING GUIDELINES FOR AERO-252 (Pages 1 to 3 contain general information on CO Guardian. Pages 4 to 6 contain information specific to Aero 252)
OPEARATING GUIDELINES FOR AERO-252 (Pages 1 to 3 contain general information on CO Guardian. Pages 4 to 6 contain information specific to Aero 252) What is Carbon Monoxide? Carbon Monoxide (CO) is a colorless,
More information1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR
1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR IMPORTANT: Please read these installation and operating instructions completely and carefully before
More informationRK/ RK Carbon Monoxide Detector Operator s Manual
65-2496RK/65-2499RK Carbon Monoxide Detector Operator s Manual Part Number: 71-0156RK Revision: 0 Released: 2/16/11 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating
More informationUser Guide. for the Beacon ProActTM 200 System
TM User Guide for the Beacon ProActTM 200 System BEACON recommends that this product, like all sump pumprelated products, be installed by or under the supervision of a professional plumbing contractor.
More informationControllers. Instruction Manual WARNING
Controllers Instruction Manual WARNING THIS MANUAL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR INSTALLING, USING OR SERVICING THIS PRODUCT. Like any piece of
More informationGAS MONITOR Model Model
Sierra Monitor Corporation 1991 Tarob Court, Milpitas, CA 95035 (408) 262-6611 (800) 727-4377 (408) 262-9042 - Fax E-mail: sierra@sierramonitor.com Web Site: www.sierramonitor.com GAS MONITOR Model 2350-00
More informationC-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL
C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL Clipsal and C-Bus are registered trademarks of Clipsal Australia Pty Ltd ABN 27 007 873 529. Copyright Clipsal Australia Pty Ltd 2008. All rights reserved.
More informationGlobal Water Instrumentation, Inc.
Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 High Water Alarm WA400-DC WA400-AC WA400-BU WA400-FS WA400-AL 10/23/06 P/N: 01-527
More informationDocument No
CO Guardian LLC 1951 E. Airport Dr. Tucson, AZ 85706 CARBON MONOXIDE DETECTOR MODEL 452 INSTALLATION AND OPERATIONAL MANUAL Document No. 01-2510-02 MODEL 452 INSTALLATION AND OPERATIONAL MANUAL Page 1
More informationModels LBW-420-LEL (24 VDC powered) Ammonia Leak Detector
Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector CAUTION & SYMBOL DEFINITIONS: CAUTION: Gives detailed description of different situations to avoid or not avoid for the proper operation of the
More informationSMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS
SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS CONTENTS 1. INTRODUCTION... 5 2. WARNINGS... 6 3. GENERAL DESCRIPTION... 7 4. INSTALLATION... 8 5. LUMINOUS INDICATORS AND COMMANDS... 9 6. DIP-SWITCH
More informationTechnical Manual. LeakFilm 5. 5 Channel Conductive Liquid Leak Detection Controller
Technical Manual LeakFilm 5 5 Channel Conductive Liquid Leak Detection Controller 1. Safety Ensure that this Operating Manual is read and understood BEFORE installing / operating / maintaining the equipment.
More informationU S E R M A N U A L UBH1RF HEAT ALARM
U S E R M A N U A L UBH1RF HEAT ALARM OverView This heat alarm is a fire detection and alarm device which gives off an audible and visual warning when the ambient temperature reaches 54 C to 70 C. These
More informationQAS SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR
QAS-10000 SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR INSTALLATION, OPERATION AND MAINTENANCE MANUAL QUATROSENSE ENVIRONMENTAL LTD. 5935 OTTAWA STREET, PO BOX 749, RICHMOND, ONTARIO, CANADA. K0A
More informationUser s Manual For Model Aero-551 (Rev. Orig.)
User s Manual For Model Aero-551 (Rev. Orig.) Document: 551-100 REV A LOG OF REVISIONS REV NO. PAGE NO. DATE DESCRIPTION APPROVED Orig. 1 thru 5 12/4/06 Initial Release ASH VIJ A 2 and 3 10/22/06 Deleted
More informationRemote Relay Module (RRM)
Remote Relay Module (RRM) Instruction Manual WARNING THIS MANUAL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR INSTALLING, USING OR SERVICING THIS PRODUCT. Like
More informationBX444-Mc Gas Detector
Installation and User Guide Rev.01. BX444-Mc Gas Detector Application Duomo is recognised within the gas industry for providing a comprehensive range of low cost, high reliability gas detection for many
More informationInstruction Manual WARNING
Controllers Instruction Manual WARNING THIS MANAUL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR INSTALLING, USING OR SERVICING THIS PRODUCT. Like any piece of
More informationTHERMAX Efficiency Monitor
INSTALLATION & OPERATION INSTRUCTIONS THERMAX Efficiency Monitor Oil & Gas Fired Heating Equipment Efficiency Monitoring Instrument Important Safety Instructions Read and safe these instructions before
More informationInstruction Manual. Electronic gas and smoke detector GRM
Mess-, Regel- und Überwachungsgeräte für Haustechnik, Industrie und Umweltschutz Lindenstraße 20 DE-74363 Güglingen Telefon +49(0)7135-102-0 Service +49(0)7135-102-211 Telefax +49(0)7135-102-147 E-Mail
More informationCellular Alarm Quick Start Installation Guide
Cellular Alarm Quick Start Installation Guide Copyright 2017, PumpAlarm.com, All Rights Reserved Please scan the image on the right with your smartphone to view our installation video, or simply visit
More informationExternal Wireless Sounder
External Wireless Sounder Model: WL RWS401 Installation and Programming Instructions Table of Contents Introduction... 3 Operational Functions... 3 Alarm / Tamper Indication... 3 Low Battery Indication...
More informationRAM3 Remote Alarm Module
RAM3 Remote Alarm Module INSTRUCTIONS Installation and Operation of the AMC-RAM3 with AMC Monitors IMPORTANT: Please read this installation and operating instructions completely and carefully before starting.
More informationInstruction Manual. AcuRite Atlas. Indoor Display model 06061
Instruction Manual AcuRite Atlas Indoor Display model 06061 How It Works AcuRite Atlas is an environmental monitoring station that delivers key information on current outdoor conditions in your exact location.
More informationLMA LINE MONITOR ALERT USER S MANUAL
LMA LINE MONITOR ALERT USER S MANUAL Janus is a brand of Avire Avire Inc 415 Oser Avenue, Suite Q, Hauppauge, New York 11788 Phone: 631 864 3699 Toll Free: 800 527 9156 Fax: 631 864 2631 Email: sales.us@avire-global.com
More informationRoom Monitor SAVE THIS MANUAL FOR FUTURE REFERENCE.
Instruction Manual Room Monitor model 00276RM CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2 Features & Benefits... 3 Setup... 4 Placement Guidelines... 5 Using the
More informationFalcon-II Next Generation, Air Quality Monitor CO2 & Temperature
Critical Environment Technologies Canada Inc. Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature OPERATION MANUAL REV: A JUNE-2-2008 #145, 7391 Vantage Way Delta, BC V4G 1M3 Canada Phone:
More informationKFP-CF Series Operation Manual
KFP-CF Series Operation Manual P/N 501-415103-2-31 REV 03.10 ISS 13NOV13 Copyright Trademarks and patents Manufacturer Version Certification European Union directives Contact information 2013 UTC Fire
More informationHumidity Monitor model 01080
Instruction Manual Humidity Monitor model 01080 Features & Benefits 19 18 1 2 3 4 12 11 10 17 16 5 9 RECORDS ºC/ºF 15 14 FRONT 6 7 8 1. Humidity Level Indicator Indicates a high, low or ideal humidity
More informationC-Bus Black & White MK II Desktop Touchscreen. 5000CTD2 Series. User s Guide REGISTERED DESIGN REGISTERED PATENT
C-Bus Black & White MK II Desktop Touchscreen 5000CTD2 Series REGISTERED DESIGN REGISTERED PATENT Clipsal is a registered trademark of Clipsal Australia Pty Ltd ABN 27 007 873 529. C-Bus is a registered
More informationSYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System
SYSTEM MANUAL FT1-SB Single Zone Fire Alarm System DOCUMENT HISTORY Issue Date Description Written By Checked By Draft 0 2/9/2008 Original Document. A. Shenouda C. Orr Issue 1 4/11/2011 Update drawing
More informationINSTRUCTION MANUAL PC255O
INSTRUCTION MANUAL PC255O Canadian Department of Communications Notice NOTICE: The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment
More informationMicrOTDR. Optical Fault Locator. User Manual
Optical Fault Locator Datacom Textron 11001 31 st Place West Everett, WA 98204 TEL: 425-355-0590 Toll Free: 800-468-5557 FAX: 425-290-1600 Internet: www.datacom.textron.com Warranty The MicrOTDR Optical
More informationAMC-CD2. Human Occupancy Detector INSTRUCTION MANUAL. Please read these instructions completely and carefully before starting.
AMC-CD2 Human Occupancy Detector INSTRUCTION MANUAL IMPORTANT: Please read these instructions completely and carefully before starting. filename: 3138405D.doc Revised, 04/2015 Copyright, May 2002, AMC
More informationRK-05 Carbon Monoxide Detector Operator s Manual
65-2433RK-05 Carbon Monoxide Detector Operator s Manual Part Number: 71-0189RK Revision: 0 Released: 5/17/11 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual
More informationQuantum Production Limited
Quantum Production Limited TELEPHONE NUMBER +44 (0) 1844 339993 FAX NUMBER: +44 (0) 1844 339996 ONE 2 ONE OXYGEN DEFICIENCY MONITOR & REPEATER ALARM Description and Application Installation and Operating
More informationOWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ.
OWNERS MANUAL CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) (353-101 and 353-201) 353 FAMILY MODEL OWNERS/INSTALLATION MANUAL Page 1 of 22 LOG OF REVISIONS REV NO. PAGE NO. DATE DESCRIPTION
More informationMacurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions
Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions Important: Keep these User Instructions for reference 2 TABLE OF CONTENTS GENERAL SAFETY
More informationNEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL
NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL 456 Creamery Way, Exton, PA 19341, USA Phone: 610.524.8800 Fax: 610.524.8807 Email: info@refrigerantid.com www.refrigerantid.com Page
More informationINSTRUCTION MANUAL PC255O
INSTRUCTION MANUAL PC255O Canadian Department of Communications Notice NOTICE: The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment
More informationMark 25 Ultrapure Water Conductivity Analyzer
Martek Instruments, Inc. Mark 25 Ultrapure Water Conductivity Analyzer Instruction Manual WARRANTY POLICY Unless otherwise stated, MARTEK INSTRUMENTS, INC. warrants this equipment to be free from defects
More informationCO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL
OWNERS MANUAL CARBON MONOXIDE DETECTOR MODELS Panel mount and Remote Detectors (R) (353 and 353R) 353 FAMILY MODEL OWNERS/INSTALLATION MANUAL Page 1 of 22 LOG OF REVISIONS REV NO. PAGE NO. DATE DESCRIPTION
More informationModel 405 AIRGARD Fume Hood Monitor
INSTALLATION AND MAINTENANCE INSTRUCTIONS Model 405 AIRGARD Fume Hood Monitor A TSI Company Model 405 AIRGARD Fume Hood Monitor Specifications Instrument Dimensions Instrument Weight Shipping Weight Green
More informationInstallation and Operations Manual
Installation and Operations Manual H-IM-LLC February 2018 Part No. 25092501 Replaces H-IM-LLC (01/2014) Lead Lag Control System Table of Contents General Safety Information 2 Inspection 2 Warranty Statement
More informationWATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector
WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector IMPORTANT READ THIS FIRST....3 CAUTIONS... 3 AVOIDING NUISANCE ALARMS... 3 STANDARD FEATURES... 4 AVAILABLE OPTIONS... 4 PARTS DESCRIPTION... 5 FRONT PANEL
More informationAMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.
AMC-RAM-4 Refrigerant Alarm Module USER MANUAL IMPORTANT: Please read the installation and operating instructions completely and carefully before starting. Filename: 3310405B, DOC, AMC_RAM4_Manual.doc
More informationRECON/4a Portable Multi-Gas Detector Operation and Maintenance Manual
680 Fairfield Court Ann Arbor, MI 48108 734.761.1270 Fax 734.761.3220 www.enmet.com RECON/4a Portable Multi-Gas Detector Operation and Maintenance Manual Table of Contents 1.0 INTRODUCTION... 2 1.1 Unpack...
More informationRK-02 Multi Point Detector Operator s Manual
65-2485RK-02 Multi Point Detector Operator s Manual Part Number: 71-0237RK Revision: A Released: 11/26/14 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual
More informationInstruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!
Mess-, Regel- und Überwachungsgeräte für Haustechnik, Industrie und Umweltschutz Lindenstraße 20 74363 Güglingen Telefon +49 7135-102-0 Service +49 7135-102-211 Telefax +49 7135-102-147 info@afriso.de
More informationZC450-IB-09/13-01 US. Instruction Booklet. Zonecheck 450
ZC450-IB-09/13-01 US Instruction Booklet Zonecheck 450 Zonecheck 450 Copyright This instruction booklet is property of Project Fire Products Ltd and must not be used or copied without its written permission.
More informationOPERATION MANUAL Part No s. P8003V10C, P8004V10C
P8003/P8004 Proxswitch INDUCTIVE PROXIMITY SENSOR C US APPROVED Class II Div. 1 INSTALLATION INSTRUCTIONS OPERATION MANUAL Part No s. P8003V10C, P8004V10C www.go4b.com/usa TABLE OF CONTENTS CUSTOMER SAFETY
More informationA series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.
Belonging to Made in Italy GS911K Gas Detector GS911K Using the catalytic sensor inside it, the GS911K detector detects the presence of explosive gas such as: Methane, LPG, with trip sensitivity calibrated
More informationBeacon 110 Gas Monitor Operator s Manual
Beacon 110 Gas Monitor Operator s Manual Part Number: 71-0110RK Revision: H Released: 12/5/17 RKI Instruments, Inc. www.rkiinstruments.com Product Warranty RKI Instruments, Inc., warrants gas alarm equipment
More informationWireless Base Remote Test and Hush
1209-7202-00(21008428)_V5_a1:_ 2011.1.10 4:50 PM Page 1 Wireless Base Remote Test and Hush KN-RTH-RF Wireless Remote For use with RF-SFTP 230V Mains Operated Wireless Base Thank you for purchasing a Kidde
More informationDigital Refrigerator/Freezer Thermometer model 00986
Instruction Manual Digital Refrigerator/Freezer Thermometer model 00986 CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2 Features & Benefits: Sensors... 2 Features &
More informationRK-OXY Oxygen Sample-Draw Detector Operator s Manual Part Number: RK Revision: P1 Released: 7/18/02
35-3000RK-OXY Oxygen Sample-Draw Detector Operator s Manual Part Number: 71-0071RK Revision: P1 Released: 7/18/02 RKI Instruments Inc. 1855 Whipple Road Hayward, CA 94544 PH: 800-754-5165 Fax: 510-441-5650
More informationINSTRUCTION MANUAL FOR RIKEN PORTABLE TOXIC GAS MONITOR
INSTRUCTION MANUAL FOR RIKEN PORTABLE TOXIC GAS MONITOR Special Cautions Please read this instruction manual before any operation. * This instrument is not designed for the explosion proof. * Avoid hard
More informationLifeTag System Operation Guide
81275_3.book Page 1 Friday, July 28, 2006 8:48 AM LifeTag System Operation Guide Document reference: 81275-3 Date: July 2006 81275_3.book Page 2 Friday, July 28, 2006 8:48 AM Raymarine and SeaTalk are
More informationFUME HOOD MONITOR ALNOR AIRGARD 200
FUME HOOD MONITOR ALNOR AIRGARD 200 OWNER S MANUAL P/N 116670080, REV 09 SEPTEMBER 2014 LIMITATION OF WARRANTY AND LIABILITY (effective April 2014) (For country-specific terms and conditions outside of
More informationCO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE
CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE GasAlertMicro 5 IR from Refer to for more details. Manual provided on CD with unit at time of purchase 2 Table of Contents Getting Started.
More informationUser s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM
User s Guide Shop online at omega.com SM e-mail: info@omega.com For latest product manuals: www.omegamanual.info HHAQ-109 Portable Multi-gas Detector User Guide Thanks for our using our products. Before
More information