NS Series Network Sensors

Size: px
Start display at page:

Download "NS Series Network Sensors"

Transcription

1 NS Series Network s Bulletin AHx7x0x-x, APx7x0x-0, ATx700x-x, BCN7004-x, BHx7x0x-0, BPx700x-0, BTx700x-x, DTN70x3-0, FTN7003-x, MHL700x-0, MNN700x-0, MTx700x-0 No. LIT Issued March 4, 2013 Supersedes April 25, 2012 Refer to the QuickLIT website for the most up-to-date version of this document. The NS Series Network offering includes NS Series Network Zone s and NS Series Network Discharge Air s. The NS Series Network s are designed to function directly with Metasys system Field Equipment Controllers (FECs), Input/Output Modules (IOMs), Variable Air Volume (VAV) Modular Assembly (VMA16) controllers, and Facility Explorer FX-PC Series Programmable Controllers (FX-PCGs, FX-PCVs, and FX-PCXs). The majority of NS Series Network Zone s monitor room temperature; however, options are available to also monitor zone humidity, carbon dioxide (CO 2 ), local temperature setpoint adjustments, and other variables. This data is transmitted to a controller on the Actuator (SA) Bus. Some models of NS Series Network Zone s include an onboard passive infrared () occupancy sensor that detects motion to determine if a space is occupied. This feature maximizes up to 30% energy savings in high-energy usage environments such as schools, dormitories, offices, hospitals, and hotels by adjusting the temperature of the space based on the occupancy status. In addition, the occupancy sensor facilitates trending of floor space usage in these environments. The NS Series Network Zone s include models with a temperature setpoint dial and Liquid Crystal (LCD) that allows occupants to view the zone temperature, Relative Humidity (RH), and view and adjust the zone temperature setpoint. Some temperature and humidity models include a push button to toggle between temperature and RH on the display. These models also have the capability to set the desired default display to either temperature or RH. A fan mode push button is included to set the desired fan speed (AUTO-OFF-low-medium-high). An occupancy override function allows the user to signal the controller that the zone is occupied to override the scheduled mode. Some models have DIP switches to set a unique address for applications that require multiple sensors. For communication wiring flexibility, the wires connecting the network zone sensor to a controller can be terminated using a modular jack or screw terminals. Figure 1: NS Series Network s Each network sensor includes an SA Bus access port to allow accessories to access the SA Bus. This plug allows accessories to service or commission the connected controller or gain access to any other controller on the same Field Controller (FC) Bus. The NS Series Network Zone offering includes models that can be surface mounted, vertical wallbox mounted, or flush mounted to meet the requirements of the specific application. The NS Series Network Discharge Air s monitor the duct temperature, typically at the discharge of the VAV box, and transmit this data to a local controller on the SA Bus using the 10 ft (305 cm) wiring lead included with the unit. The 10 ft (305 cm) wiring lead consists of four 22 AWG (0.6 mm) trade size color-coded wires encased in a plenum-rated jacket. Each of the wires is stripped and tinned for easy connection to the SA Bus screw terminal block. The NS Series Network Discharge Air s are available with either a 4 or 8 in. (102 or 203 mm) temperature probe. All models include DIP switches for applications requiring multiple discharge air sensors, each with a unique DIP switch address. NS Series Network s Bulletin 1

2 Table 1: Features and Benefits Features BACnet Master-Slave/Token-Passing (MS/TP) Protocol Communication Backlit LCD Available on Some Models Simple Adjustment Available on Some Models Onboard Available on Some Models Temporary Available on Some Models Field-Selectable Default Setting on Some Models Fahrenheit/Celsius (F/C) Button Available on Some Models Benefits Provides compatibility with Metasys system field controllers and Facility Explorer programmable controllers in a proven communication network. Provides real-time status of the environment with backlighting activated during user interaction. Enables you to change the setpoint with the turn of a dial. Maximizes up to 30% energy savings in high-energy usage environments, and facilitates trending of floor space usage. Provides a timed override command, which temporarily initiates an alternate mode. Allows you to toggle between temperature and RH on the display, and set the desired default for continuous viewing. Toggles the display temperature between degrees Celsius and degrees Fahrenheit. Ordering Information Table 2 through Table 7 list the various NS Series Network Zone s available, and Table 8 lists the various NS Series Network Discharge Air s available. IMPORTANT: The NS Series Network is intended to provide an input to equipment under normal operating conditions. Where failure or malfunction of the network sensor could lead to personal injury or property damage to the controlled equipment or other property, additional precautions must be designed into the control system. Incorporate and maintain other devices, such as supervisory or alarm systems or safety or limit controls, intended to warn of or protect against failure or malfunction of the network sensor. Repair Information If the NS Series Network Zone or the NS Series Network Discharge Air fails to operate within its specifications, replace the unit. For a replacement sensor, contact the nearest Johnson Controls representative. Table 2: Network Zone Ordering Information Only Models (Part 1 of 3) Johnson LCD Controls F/C Scale Toggle Fan Control ATA ATA ATA ATB ATB Override Button, Terminals (ST) or Modular 80 x 80 SM Yes Yes Set Yes, No No No MJ No No 80 x 80 SM Yes Yes Set Yes, No No No ST No No 80 x 80 SM Yes Yes Set Yes, No No No ST Yes No 80 x 80 SM Yes Yes Set Yes, No Yes No MJ No No 80 x 80 SM Yes Yes Set Yes, No Yes No ST No No VAV Balancing Feature 2 NS Series Network s Bulletin

3 Table 2: Network Zone Ordering Information Only Models (Part 2 of 3) Johnson LCD Controls F/C Scale Toggle Fan Control ATB ATC ATC ATD ATD ATF ATF ATN ATN ATN ATN ATP ATP ATP ATP ATP ATP ATV ATV BTB BTB BTB BTB BTB Override Button, Terminals (ST) or Modular 80 x 80 SM Yes Yes Set Yes, No Yes No ST Yes No 80 x 80 SM Yes Yes Set Yes, No No Yes MJ No No 80 x 80 SM Yes Yes Set Yes, No No Yes ST No No 80 x 80 SM Yes Yes Set Yes, No Yes Yes MJ No No 80 x 80 SM Yes Yes Set Yes, No Yes Yes ST No No 80 x 80 SM Yes Yes W/C Yes, No Yes No MJ No No 80 x 80 SM Yes Yes W/C Yes, No Yes No ST No No 80 x 80 SM Yes No N/A No, No No No MJ No No 80 x 80 SM No No N/A No, No No No MJ No No 80 x 80 SM Yes No N/A No, No No No ST Yes No 80 x 80 SM No No N/A No, No No No ST Yes No 80 x 80 SM Yes No W/C Yes, No No No MJ No No 80 x 80 SM No No W/C Yes, No No No MJ No No 80 x 80 SM Yes No W/C Yes, No No No ST No No 80 x 80 SM No No W/C Yes, No No No ST No No 80 x 80 SM Yes No W/C Yes, No No No ST Yes No 80 x 80 SM No No W/C Yes, No No No ST Yes No 80 x 80 SM Yes Yes Set Yes, No Yes No 1 MJ No Yes 80 x 80 SM Yes Yes Set Yes, No Yes No 1 ST No Yes 120 x 80 WB, SM Yes Yes Set Yes, No Yes No MJ No No 120 x 80 WB, SM No Yes Set Yes, No Yes No MJ No No 120 x 80 WB, SM Yes Yes Set Yes, No Yes No ST No No 120 x 80 WB, SM Yes Yes Set Yes, No Yes No ST Yes No 120 x 80 WB, SM No Yes Set Yes, No Yes No ST Yes No VAV Balancing Feature NS Series Network s Bulletin 3

4 Table 2: Network Zone Ordering Information Only Models (Part 3 of 3) Johnson LCD Controls F/C Scale Toggle Fan Control 120 x 80 WB, SM Yes Yes W/C Yes, No Yes No MJ No No BTF x 80 WB, SM Yes Yes W/C Yes, No Yes No ST No No BTF x 80 WB, SM Yes No N/A No, No No No MJ No No BTN x 80 WB, SM No No N/A No, No No No MJ No No BTN x 80 WB, SM Yes No N/A No, No No No ST Yes No BTN x 80 WB, SM No No N/A No, No No No ST Yes No BTN x 80 WB, SM Yes No W/C Yes, No No No MJ No No BTP x 80 WB, SM No No W/C Yes, No No No MJ No No BTP x 80 WB, SM Yes No W/C Yes, No No No ST No No BTP x 80 WB, SM No No W/C Yes, No No No ST No No BTP x 80 WB, SM Yes No W/C Yes, No No No ST Yes No BTP x 80 WB, SM Yes Yes Set Yes, No Yes No 1 MJ No Yes BTV x 80 WB, SM Yes Yes Set Yes, No Yes No 1 ST No Yes BTV x 80 WB, SM Yes Yes Set No, Yes Yes No MJ No No MTB x 80 WB, SM Yes Yes Set No, Yes Yes No ST No No MTB x 80 WB, SM Yes No N/A Yes, Yes No No MJ No No MTL MTL x 80 WB, SM Yes No N/A Yes, Yes No No ST No No 1. In the VAV balancing models, the fan control button is replaced by a light bulb button used in the VAV balancing process. Table 3: Network Zone Ordering Information and Humidity Models without RH (Part 1 of 2) Johnson Controls Humidity Element Accuracy LCD, RH Override Button, Terminals (ST) or Modular F/C Override Scale Button, Toggle Terminals (ST) or Modular AHA x 80 SM Yes Yes, No 3% Set Yes, No No MJ No AHA x 80 SM Yes Yes, No 3% Set Yes, No No ST No AHB x 80 SM Yes Yes, No 3% Set Yes, No Yes MJ No VAV Balancing Feature 4 NS Series Network s Bulletin

5 Table 3: Network Zone Ordering Information and Humidity Models without RH (Part 2 of 2) Johnson Controls Humidity Element Accuracy AHB x 80 SM Yes Yes, No 3% Set Yes, No Yes ST No AHB x 80 SM Yes Yes, No 3% Set Yes, No Yes ST Yes AHN x 80 SM Yes None 3% N/A No, No No MJ No AHN x 80 SM No None 3% N/A No, No No MJ No AHP x 80 SM Yes None 3% W/C Yes, No No MJ No APA x 80 SM Yes Yes, No 2% Set Yes, No No MJ No APA x 80 SM Yes Yes, No 2% Set Yes, No No ST No APB x 80 SM Yes Yes, No 2% Set Yes, No Yes MJ No APB x 80 SM Yes Yes, No 2% Set Yes, No Yes ST No APB x 80 SM Yes Yes, No 2% Set Yes, No Yes ST Yes BHB x 80 WB, SM Yes Yes, No 3% Set Yes, No Yes MJ No BHB x 80 WB, SM Yes Yes, No 3% Set Yes, No Yes ST No BHB x 80 WB, SM Yes Yes, No 3% Set Yes, No Yes ST Yes BHN x 80 WB, SM Yes None 3% N/A No, No No MJ No BHN x 80 WB, SM No None 3% N/A No, No No MJ No BHP x 80 WB, SM Yes None 3% W/C Yes, No No MJ No BPB x 80 WB, SM Yes Yes, No 2% Set Yes, No Yes MJ No BPB x 80 WB, SM Yes Yes, No 2% Set Yes, No Yes ST No BPB x 80 WB, SM Yes Yes, No 2% Set Yes, No Yes ST Yes MHL x 80 WB, SM Yes No, No 3% N/A Yes, Yes No MJ No MHL x 80 WB, SM Yes No, No 3% N/A Yes, Yes No ST No Table 4: Network Zone Ordering Information and Humidity Models with or RH (Field-Selectable Default ) Humidity Element Accuracy Override Button F/C Scale Toggle LCD, RH LCD, RH F/C Override Scale Button, Toggle Terminals (ST) or Modular Terminals (ST) or Modular AHR x 80 SM Yes, Yes 3% Set Yes Yes MJ No AHR x 80 SM Yes, Yes 3% Set Yes Yes ST No AHR x 80 SM Yes, Yes 3% Set Yes Yes ST Yes APR x 80 SM Yes, Yes 2% Set Yes Yes MJ No APR x 80 SM Yes, Yes 2% Set Yes Yes ST No BHR x 80 WB, SM Yes, Yes 3% Set Yes Yes MJ No BHR x 80 WB, SM Yes, Yes 3% Set Yes Yes ST Yes NS Series Network s Bulletin 5

6 Table 5: Network Zone Ordering Information Motion Detection Only Models (No or Humidity Sensing) LCD (WB), or Terminals (ST), or Modular MNN x 80 WB, SM No Yes MJ No MNN x 80 WB, SM No Yes ST Yes Table 6: Network Zone Ordering Information CO 2 Models LCD (mm) (WB), or CO 2 Measurement Range Johnson Controls Terminals (ST), or Modular ing BCN x 80 WB, SM No 0 to 2,000 ppm Yes ST, MJ DIP Switch (212 to 219) BCN x 80 WB, SM No 0 to 2,000 ppm No ST, MJ DIP Switch (212 to 219) Table 7: Network Zone Ordering Information Flush-Mount Only Models Mounting LCD FTN FTN Faceplate Dimensions, 4-1/2 in. x 2-3/4 in. (114 mm x 70 mm) 4-1/2 in. x 2-3/4 in. (114 mm x 70 mm) Measurement Range Flush-Mount No 32.0 F/0.0 C to F/40.0 C Flush-Mount No 32.0 F/0.0 C to F/40.0 C Johnson Controls Table 8: Network Discharge Air Ordering Information Dimensions, HeightxxDepth Probe Length 10 ft (305 cm) Wiring Lead Included DTN DTN in. x 3 in. x 2 in. (76 mm x 76 mm x 51 mm) 3 in. x 3 in. x 2 in. (76 mm x 76 mm x 51 mm) ing Technical Specifications NS Series Network Zone s Only Models and and Humidity Models (Part 1 of 2) Supply Voltage Current Consumption ing Yes No Terminal Block Terminal Block DIP Switch (200 to 203) DIP Switch (200 to 203) ing 4 in. (102 mm) Yes Terminal Block DIP Switch (204 to 211) 8 in. (203 mm) Yes Terminal Block DIP Switch (204 to 211) 9.8 to 16.5 VDC; 15 VDC Nominal (From SA Bus) Only Models with LCD : 21 ma Maximum (Non-transmitting) Only Models without LCD : 13 ma Maximum (Non-transmitting) and Humidity Models with LCD : 25 ma Maximum (Non-transmitting) and Humidity Models without LCD : 17 ma Maximum (Non-transmitting) Modular Jack or Terminal Block AHx7003-0, APB7003-0, ATx7003-0, BHx7003-0, BPB7003-0, BTB7003-0, BTN7003-0, and BTP Models: DIP Switch Set from 200 to 203; Factory Set at 203 All Other Models: Fixed of NS Series Network s Bulletin

7 NS Series Network Zone s Only Models and and Humidity Models (Part 2 of 2) Wire Communication Rate Mounting Measurement Range Humidity Measurement Range Type Humidity Type Resolution (Models with LCD) Accuracy Humidity Element Accuracy Time Constant Default Adjustment Range Motion Detection (Models with ) Ambient Conditions Compliance BACnet International United States Canada Europe Australia and New Zealand Accessory (Order Separately) Shipping Weight Modular Jack Models: 24 AWG or 26 AWG (0.5 or 0.4 mm Diameter) Recommended; Three Twisted Pair (Six Conductors) Terminal Block Models: 18 to 22 AWG (1.0 to 0.6 mm Diameter); 22 AWG (0.6 mm Diameter) Recommended Auto-Detect: 9.6k, 19.2k, 38.4k, or 76.8k bps : 80 x 80 mm or : 120 x 80 mm 32.0 F/0.0 C to F/40.0 C Full Range: 0 to 100% RH Calibrated Range: 10 to 90% RH Local Platinum Resistance Detector (RTD) Thin Film Capacitive ±0.5F /±0.5C ±1.0F /±0.6C APx700x-0 and BPB700x-0 Models: ±2% RH for 20 to 80% RH; ±4% RH for 10 to 20% and 80 to 90% RH AHx700x-0, BHx700x-0, and MHL700x-0 Models: ±3% RH for 20 to 80% RH; ±6% RH for 10 to 20% and 80 to 90% RH 10 Minutes Nominal at 10 fpm Airflow With LCD : 50.0 F/10.0 C to 86.0 F/30.0 C in 0.5 Increments Without LCD : ±5.0F /±3.0C Minimum 94 Angular Degrees up to a Distance of 15 ft (4.6 m); Based on a Clear Line of Sight Operating: 32 to 104 F (0 to 40 C); 10 to 90% RH, Noncondensing; 85 F (29 C) Maximum Dew Point Storage with LCD : -4 to 140 F (-20 to 60 C); 5 to 95% RH, Noncondensing Storage without LCD : -40 to 158 F (-40 to 70 C); 5 to 95% RH, Noncondensing BACnet Testing Laboratories (BTL) Listed BACnet Smart (B-SS) Note: Excludes the ATV700x-0 and BTV700x-0 models. UL Listed, File E107041, CCN PAZX, Under UL 916, Energy Management Equipment; FCC Compliant to CFR 47, Part 15, Subpart B, Class A UL Listed, File E107041, CCN PAZX7, Under CAN/CSA C22.2 No. 205, Signal Equipment; Industry Canada, ICES-003 CE Mark Johnson Controls, Inc., declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive 2004/108/EC. C-Tick Mark, Australia/NZ Emissions Compliant WALLPLATE-0: Adapts an 80 x 80 mm NS Series Network Zone to a Standard 80 x 120 mm Wallbox Axx7xxx-0 Models: 0.20 lb (0.09 kg) Bxx7xxx-0 and Mxx700x-0 Models: 0.25 lb (0.11 kg) NS Series Network s Bulletin 7

8 NS Series Network Zone s Motion Detection Only Models (No or Humidity Sensing) Supply Voltage 9.8 to 16.5 VDC; 15 VDC Nominal (From SA Bus) Current Consumption 13 ma Maximum (Non-transmitting) Modular Jack or Terminal Block ing DIP Switch Set from 200 to 203; Factory Set at 203 (MNN Model) Wire Modular Jack Model: 24 AWG or 26 AWG (0.5 or 0.4 mm Diameter) Recommended; Three Twisted Pair (Six Conductors) Terminal Block Model: 18 to 22 AWG (1.0 to 0.6 mm Diameter); 22 AWG (0.6 mm Diameter) Recommended Communication Rate Auto-Detect: 9.6k, 19.2k, 38.4k, or 76.8k bps Mounting or : 120 x 80 mm Motion Detection Ambient Conditions Compliance Shipping Weight BACnet International United States Canada Europe Australia and New Zealand Minimum 94 Angular Degrees up to a Distance of 15 ft (4.6 m); Based on a Clear Line of Sight Operating: 32 to 104 F (0 to 40 C); 10 to 90% RH, Noncondensing; 85 F (29 C) Maximum Dew Point Storage: -40 to 158 F (-40 to 70 C); 5 to 95% RH, Noncondensing BACnet Testing Laboratories (BTL) Listed BACnet Smart (B-SS) UL Listed, File E107041, CCN PAZX, Under UL 916, Energy Management Equipment; FCC Compliant to CFR 47, Part 15, Subpart B, Class A UL Listed, File E107041, CCN PAZX7, Under CAN/CSA C22.2 No. 205, Signal Equipment; Industry Canada, ICES-003 CE Mark Johnson Controls, Inc., declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive 2004/108/EC. C-Tick Mark, Australia/NZ Emissions Compliant 0.25 lb (0.11 kg) 8 NS Series Network s Bulletin

9 NS Series Network Zone CO 2 Models Supply Voltage Non-isolated: 20 to 30 VAC (18 to 30 VDC), Class 2 or Safety Extra-Low Voltage (SELV) Isolated: 9.8 to 16.5 VDC; 15 VDC Nominal (From SA Bus) Current Consumption Non-isolated: 22 ma Average at 24 VAC; 28 ma Average at 24 VDC Isolated: 5 ma Maximum, Non-transmitting (From SA Bus) Power Consumption Non-isolated: Less Than 0.7 W Average Non-isolated Supply: Terminal Block SA Bus: Modular Jack or Terminal Block ing DIP Switch Set from 212 to 219; Factory Set at 212 Wire Modular Jack: 24 AWG or 26 AWG (0.5 or 0.4 mm Diameter) Recommended; Three Twisted Pair (Six Conductors) Terminal Block: 18 to 22 AWG (1.0 to 0.6 mm Diameter); 22 AWG (0.6 mm Diameter) Recommended Communication Rate Auto-Detect: 9.6k, 19.2k, 38.4k, or 76.8k bps CO 2 Measurement Range 0 to 2,000 ppm CO 2 Sensing Accuracy Plus or Minus the Sum of 50 ppm and 3.0% of the CO 2 Reading at 77 F (25 C) and 978 hpa or an Altitude of 1,000 ft/300 m Note: All accuracy specifications reflect the testing of the device using high-grade certified gases. This device is intended for an altitude range of 0 ft/0 m to 2,000 ft/600 m above sea level without compensation. Dependence of Output: -0.35% of the CO 2 Reading per 1.8F /1C Typical Pressure Dependence of Output: +0.15% of the CO 2 Reading per 1 hpa Typical CO 2 Sensing Resolution 1 ppm CO 2 Sensing Response Time 1 Minute (0 to 90%) CO 2 Sensing Warm-Up Time Less Than 1 Minute; Less Than 10 Minutes for Full Accuracy CO 2 Sensing Long-Term Stability Less Than ±100 ppm Over 5 Years Mounting or : 120 x 80 mm Ambient Conditions Operating: 32 to 104 F (0 to 40 C); 10 to 90% RH, Noncondensing; 85 F (29 C) Maximum Dew Point; 700 to 1,200 hpa Storage: -40 to 158 F (-40 to 70 C); 0 to 95% RH, Noncondensing Compliance BACnet BACnet Testing Laboratories (BTL) Listed BACnet Smart (B-SS) International United States UL Listed, File E CCN PAZX, Under UL 916, Energy Management Equipment; FCC Compliant to CFR 47, Part 15, Subpart B, Class A Canada UL Listed, File E107041, CCN PAZX7, Under CAN/CSA C22.2 No. 205, Signal Equipment; Industry Canada, ICES-003 Europe CE Mark Johnson Controls, Inc., declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive 2004/108/EC. Australia and C-Tick Mark, Australia/NZ Emissions Compliant New Zealand Shipping Weight 0.35 lb (0.16 kg) NS Series Network s Bulletin 9

10 NS Series Network Zone Flush-Mount Only Models Supply Voltage Current Consumption 9.8 to 16.5 VDC; 15 VDC Nominal (From SA Bus) 12 ma Maximum (Non-transmitting) per Flush-Mount Network Terminal Block Note: Wire leads are field supplied and are not tinned. ing DIP Switch Set from 200 to 203; Factory Set at 203 Wire 18 to 22 AWG (1.0 to 0.6 mm Diameter); 22 AWG (0.6 mm Diameter) Recommended; 10 ft (304.8 cm) Wiring Lead Included with the Unit Communication Rate Auto-Detect: 9.6k, 19.2k, 38.4k, or 76.8k bps Measurement Range 32.0 F/0.0 C to F/40.0 C Type Local Platinum Resistance Detector (RTD) Accuracy ±1.0F /±0.6C Ambient Conditions Operating: 32 to 104 F (0 to 40 C); 10 to 90% RH, Noncondensing; 85 F (29 C) Maximum Dew Point Storage: -40 to 158 F (-40 to 70 C); 5 to 95% RH, Noncondensing Compliance BACnet BACnet Testing Laboratories (BTL) Listed BACnet Smart (B-SS) International United States UL Listed, File E107041, CCN PAZX, Under UL 916, Energy Management Equipment; FCC Compliant to CFR 47, Part 15, Subpart B, Class A Canada UL Listed, File E107041, CCN PAZX7, Under CAN/CSA C22.2 No. 205, Signal Equipment; Industry Canada, ICES-003 Europe CE Mark Johnson Controls, Inc., declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive 2004/108/EC. Australia and C-Tick Mark, Australia/NZ Emissions Compliant New Zealand Shipping Weight 0.25 lb (0.11 kg) 10 NS Series Network s Bulletin

11 NS Series Network Discharge Air s Supply Voltage Current Consumption 9.8 to 16.5 VDC; 15 VDC Nominal 12 ma Maximum (Non-transmitting) per Discharge Air Four Color-d Wiring Leads, Stripped and Tinned; Factory-Installed at the Discharge Air Terminal Block ing DIP Switch Set from 204 to 211; Factory Set at 204 Wire 18 to 22 AWG (1.0 to 0.6 mm Diameter); 22 AWG (0.6 mm Diameter) Recommended; 10 ft (305 cm) Wiring Lead Included with the Unit Communication Rate Auto-Detect: 9.6k, 19.2k, 38.4k, or 76.8k bps Mounting Duct-: 4 or 8 in. (102 or 203 mm) Probe Length Measurement Range 14 F/-10 C to 140 F/60 C Type Local Platinum Resistance Detector (RTD) Accuracy ±1.0F /±0.6C Ambient Conditions Operating: 14 to 140 F (-10 to 60 C); 10 to 90% RH, Noncondensing; 85 F (29 C) Maximum Dew Point Storage: -40 to 158 F (-40 to 70 C); 5 to 95% RH, Noncondensing Compliance BACnet BACnet Testing Laboratories (BTL) Listed BACnet Smart (B-SS) International United States UL Listed, File E107041, CCN PAZX, Under UL 916, Energy Management Equipment; FCC Compliant to CFR 47, Part 15, Subpart B, Class A Canada UL Listed, File E107041, CCN PAZX7, Under CAN/CSA C22.2 No. 205, Signal Equipment; Industry Canada, ICES-003 Europe CE Mark Johnson Controls, Inc., declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive 2004/108/EC. Australia and C-Tick Mark, Australia/NZ Emissions Compliant New Zealand Shipping Weight DTN7043-0: 1.15 lb (0.52 kg) DTN7083-0: 1.17 lb (0.53 kg) The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. United States Emissions Compliance This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area may cause harmful interference, in which case users will be required to correct the interference at their own expense. Canadian Emissions Compliance This Class (A) digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la Classe (A) respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. Building Efficiency 507 E. Michigan Street, Milwaukee, WI Metasys and Johnson Controls are registered trademarks of Johnson Controls, Inc. All other marks herein are the marks of their respective owners Johnson Controls, Inc. NS Series Network s Bulletin 11 Published in U.S.A.

NS Series Network Sensors

NS Series Network Sensors NS Series Network Sensors Bulletin AHx7x0x-x, APx7x0x-0, ATx700x-x, BCN7004-x, BHx7x0x-0, BPx700x-0, BTx700x-x, DTN70x3-0, FTN7003-2 No. LIT-12011574 Issued December 8, 2011 Supersedes August 1, 2011 Refer

More information

NS Series Network Sensors

NS Series Network Sensors Code No. LIT-1900350 Issued December 8, 2011 NS Series Network Sensors Description The NS Series Network Sensor offering includes NS Series Network Zone Sensors and NS Series Network Discharge Air Sensors.

More information

Vertical Wallbox-Mounted or Surface-Mounted NS Series Network Sensors with LCD

Vertical Wallbox-Mounted or Surface-Mounted NS Series Network Sensors with LCD Vertical Wallbox-Mounted or Surface-Mounted NS Series Network Sensors with LCD NS-BHB700x-0, NS-BHR710x-0, NS-BPB700x-0, NS-BTB700x-x, NS-BTF700x-0, NS-BTV700x-0 Applications The vertical wallbox-mounted

More information

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability Product Bulletin T601DFH-4, T602DFH-4, T603DFH-4, T604DFH-4, T605DFH-4, T601DFH-4+PIR, T602DFH-4+PIR,

More information

Surface-Mounted NS Series Network Sensors without LCD

Surface-Mounted NS Series Network Sensors without LCD Surface-Mounted NS Series Network Sensors without LCD Installation Instructions NS-AHP7001-0, NS-AHN700x-x, NS-ATN700x-x, NS-ATP700x-x 24-10094- 17, Rev. P Part No. 24-10094-17, Rev. P Issued March 2016

More information

Facility Explorer One-to-One Wireless Room Sensing System

Facility Explorer One-to-One Wireless Room Sensing System Facility Explorer One-to-One Wireless Room Sensing System Product Bulletin FX-WRZ7860-0 The Facility Explorer One-to-One Wireless Room Sensing System enables RF room sensors to wirelessly communicate to

More information

TEC3000 Series Stand-Alone and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers

TEC3000 Series Stand-Alone and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers TEC3000 Series Stand-Alone and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers TEC331x-00-000, TEC332x-00-000, TEC333x-00-000, TEC361x-00-000, TEC362x-00-000, TEC363x-00-000 Code.

More information

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs TEC2620 Series Non-Programmable Fan Coil Network Thermostat ler and Remote I/O Relay Packs TEC2620H-0, TEC2620C-0, TEC2620H-0+PIR, TEC2620C-0+PIR, TEC2621H-0, TEC2621C-0, TEC2621H-0+PIR, TEC2621C-0+PIR

More information

TEC2100 Series Networked Thermostats

TEC2100 Series Networked Thermostats Product Bulletin Issue Date February 11, 2004 TEC2100 Series Networked Thermostats The TEC2100 Series of thermostats is a family of highly advanced thermostats specifically designed for control of equipment

More information

TEC210x-2 Series Networked Thermostats

TEC210x-2 Series Networked Thermostats Product Bulletin Issue Date February 1, 2005 TEC210x-2 Series Networked Thermostats The TEC210x-2 Series of thermostats is a family of highly advanced thermostats specifically designed for control of equipment

More information

T606MSx-4 and T606MSx-4+PIR Series Multi-Stage

T606MSx-4 and T606MSx-4+PIR Series Multi-Stage T606MSx-4 and T606MSx-4+PIR Series Multi-Stage Temperature and Humidity Controllers Product Bulletin T606MSN-4, T606MSN-4+PIR, T606MSP-4, T606MSP-4+PIR The T606MSN-4 and T606MSN-4+PIR Series Non-programmable

More information

TEC1100 Series Thermostats

TEC1100 Series Thermostats Metasys Network Sales Resource Manual 635 Application Specific Controllers Section Product Bulletin Issue Date 0601 TEC1100 Series Thermostats TEC1100 is a series of non-programmable thermostats with a

More information

TEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers Catalog Page

TEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers Catalog Page Code. LIT-1900896 Issued February 17, 2017 TEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers Catalog Page Description The TEC3000 Series Thermostat

More information

P266 Series Single-Phase Condenser Fan Speed Control

P266 Series Single-Phase Condenser Fan Speed Control P266 Series Single-Phase Condenser Fan Speed Control Product Bulletin P266xxx-x Code No. LIT-12011534 Issued June 24, 2009 The P266 Single-Phase Condenser Fan Speed Control is a cost-effective, weather-resistant,

More information

TEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers

TEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers TEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers Product Bulletin TEC30xx-0x-000, TEC33xx-0x-000, TEC36xx-0x-000 Code. LIT-12011954 Issued

More information

CD-Px Series Duct Mount CO 2 Transmitters

CD-Px Series Duct Mount CO 2 Transmitters CD-Px0-00-0 Series Duct Mount CO 2 Transmitters Product Bulletin CD-P00-00-0, CD-PR0-00-0 Code No. LIT-216525 Issued October 2016 Johnson Controls offers a complete line of carbon dioxide (CO 2 ) transmitters

More information

WT-4000 Series Pneumatic-to-Direct Digital Control (DDC)

WT-4000 Series Pneumatic-to-Direct Digital Control (DDC) WT-4000 Series Pneumatic-to-Direct Digital Control (DDC) Room Thermostats Product Bulletin WT-4002-MCR, WT-4002-MCM, WT-4002-MFR, WT-4002-MFM, WT-ROUTER, WT-BAC-IP Code No. LIT-12011890 Issued August 31,

More information

F261 Series Fluid Flow Switches

F261 Series Fluid Flow Switches F261 Series Fluid Flow Switches Product Bulletin Code No. LIT-12011987 Issued July 22, 2015 Refer to the QuickLIT website for the most up-to-date version of this document. The F261 Series Flow Switches

More information

Document # R01

Document # R01 Viconics VT7600 Series PIR-Ready Rooftop Unit Controllers Part 1 General The VT7600 series is designed for single-stage and multi-stage control of heating/cooling equipment such as rooftop and self-contained

More information

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom Viconics VT7350 Series PIR Ready Fan-coil Controllers General The VT7350 series are PIR Ready low-voltage microprocessor-based fan-coil controllers. Models are available controlling single speed and multi-speed

More information

Installation Instructions

Installation Instructions 2 or 4 pipe systems model T701DFP-1 Fan Coil Thermostat 7-Day Programmable Thermostat Remote sensor ready Self-prompting programming Auto 2-pipe changeover when used with accessory changeover sensor Dry

More information

Document Introduction Annex A - Protocol Implementation Conformance Statement (Normative) Product Description... 4

Document Introduction Annex A - Protocol Implementation Conformance Statement (Normative) Product Description... 4 NS Series Temperature and Humidity Network Zone and Discharge Air Sensors and NS Series Network Sensors with Fault Code Capability Protocol Implementation Conformance Statement Technical Bulletin Code

More information

T500 Series Non-Programmable Thermostats

T500 Series Non-Programmable Thermostats FANs 216, 1628.3 Product/Technical Bulletin T500 Issue Date 0899 T500 Series Non-Programmable Thermostats T500 Series Thermostats provide an economical control solution for single-stage, multi-stage, or

More information

MR3CCUHV Temperature/Defrost Control

MR3CCUHV Temperature/Defrost Control Master Catalog 125 Temperature Controls Section A Product/Technical Bulletin Issue Date 0401 MR3CCUHV Temperature/Defrost Control The MR3CCUHV Temperature/Defrost Control is designed to control the temperature

More information

TEC BACnet MS/TP Networked Thermostat Controller with Single Proportional Output and One-Speed Fan Control

TEC BACnet MS/TP Networked Thermostat Controller with Single Proportional Output and One-Speed Fan Control TEC2645-4 BACnet MS/TP Networked Thermostat Controller with Single Proportional Output and One-Speed Fan Control Installation Instructions Part No. 24-9890-1028, Rev. B Issued June 22, 2010 Supersedes

More information

T62xx-0 Fan Coil Retrofit Thermostat Controller and R-xxxxx-0 Fan Coil Retrofit Relay Packs

T62xx-0 Fan Coil Retrofit Thermostat Controller and R-xxxxx-0 Fan Coil Retrofit Relay Packs T62xx-0 Fan Coil Retrofit Thermostat Controller and R-xxxxx-0 Fan Coil Retrofit Relay Packs T620H-0, T620C-0, T621H-0, T621C-0, R-HCC40-0, R-HCC44-0,R-MPR20-0, R-MPR24-0, R-SFC40-0 Part No. 24-9890-1419,

More information

TM-3100 Series Room Temperature Sensor

TM-3100 Series Room Temperature Sensor PB_TM-3100_12 2009 TM-3100 Series Room Temperature Sensor The Johnson Controls TM-3100 Series Room Temperature Sensor provide passive sensing of temperature in HVAC application. The TM-3100 is equipped

More information

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack Product/Technical MS4PMUHVT Issue Date 09/30/02 MS4PMUHVT Multi-Stage Electronic Control with Relay Pack The MS4PMUHVT Multi-Stage Electronic Control is intended for multi-stage temperature control applications.

More information

TEC Networked Multi-Stage Thermostat

TEC Networked Multi-Stage Thermostat Installation Instructions Issue Date September 2, 2003 TEC2103-1 Networked Multi-Stage Thermostat Application The TEC2103-1 is an N2 networked thermostat that provides control of multi-stage Heating, Ventilating,

More information

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack Master Catalog 125 Temperature Controls Section A Product/Technical Bulletin Issue Date 1098 MR4PMUHV Electronic Temperature/Defrost Control with Relay Pack The MR series temperature controls are designed

More information

TEC and TEC PIR BACnet MS/TP Networked Multi-Stage Thermostat Controllers

TEC and TEC PIR BACnet MS/TP Networked Multi-Stage Thermostat Controllers TEC2603-4 and TEC2603-4+PIR BACnet MS/TP Networked Multi-Stage Thermostat Controllers TEC2603-4 and TEC2603-4+PIR Applications The TEC2603-4 and TEC2603-4+PIR Thermostat Controllers are BACnet Master-Slave/

More information

TEC20x7-2 Series Wireless Thermostat Controllers with Two Outputs

TEC20x7-2 Series Wireless Thermostat Controllers with Two Outputs TEC20x7-2 Series Wireless Thermostat Controllers with Two Outputs Installation Instructions TEC2027-2, TEC2047-2 Part No. 24-9890-773, Rev. Release 4.0 Issued March 17, 2008 Applications IMPORTANT: The

More information

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

TRUERH Series HE-67xx Humidity Element with Temperature Sensor Installation Instructions HE-67xx Issue Date 0501 TRUERH Series HE-67xx Humidity Element with Temperature Sensor Installation IMPORTANT: The HE-67xx Series Humidity Element with Temperature Sensor is designed

More information

TEC and TEC PIR BACnet MS/TP Network Multi-Stage Temperature and Humidity Controllers

TEC and TEC PIR BACnet MS/TP Network Multi-Stage Temperature and Humidity Controllers TEC2613-4 and TEC2613-4+PIR BACnet MS/TP Network Multi-Stage Temperature and Humidity Controllers Installation Instructions TEC2613-4 and TEC2613-4+PIR Applications The TEC2613-4 and TEC2613-4+PIR Temperature

More information

TEC21x7-2 Series N2 Networked Thermostat Controllers with Two Outputs

TEC21x7-2 Series N2 Networked Thermostat Controllers with Two Outputs TEC21x7-2 Series N2 Networked Thermostat Controllers with Two Outputs Installation Instructions TEC2127-2, TEC2147-2 Part No. 24-9890-293, Rev. C Issued July 8, 2009 Supersedes May 19, 2008 Applications

More information

TEC2664Z-2 BACnet MS/TP Rooftop Controller for Stand-Alone and Networked Zoning Systems Part No , Rev. C

TEC2664Z-2 BACnet MS/TP Rooftop Controller for Stand-Alone and Networked Zoning Systems Part No , Rev. C TEC2664Z-2 BACnet MS/TP Rooftop Controller for Stand-Alone and Networked Zoning Systems Part No. 24-9890-684, Rev. C Issued March 9, 2009 Supersedes October 6, 2008 Applications The TEC2664Z-2 Rooftop

More information

T60xDFH-3 and T60xDFH-3+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

T60xDFH-3 and T60xDFH-3+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability T60xDFH-3 and T60xDFH-3+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability Installation Instructions Part No. 24-9890-692, Rev. B Issued August 31, 2009 Supersedes

More information

Johnson Controls Fan Coil Units and Direct Digital Controls

Johnson Controls Fan Coil Units and Direct Digital Controls Product Bulletin Issue Date August 12, 2005 Johnson Controls Fan Coil Units and Direct Digital Controls This offering includes Johnson Controls fan coil units with a factory-installed Johnson Controls

More information

TEC and TEC PIR N2 Networked Single-Stage Thermostat Controllers

TEC and TEC PIR N2 Networked Single-Stage Thermostat Controllers TEC2101-4 and TEC2101-4+PIR N2 Networked Single-Stage Thermostat Controllers Installation Part No. 24-9890-1206, Rev. Issued February 8, 2010 Applications The TEC2101-4 and TEC2101-4+PIR Thermostat Controllers

More information

TEC Networked Single-Stage Thermostat

TEC Networked Single-Stage Thermostat Installation Instructions Issue Date January 19, 2005 TEC2101-2 Networked Single-Stage Thermostat Application The TEC2101-2 thermostat is an N2 networked thermostat that provides control of single-stage

More information

Allure EC-Smart-Vue Sensor Series Line of communicating sensors with backlit display and graphical menus

Allure EC-Smart-Vue Sensor Series Line of communicating sensors with backlit display and graphical menus D a t a s h e e t Allure EC-Smart-Vue Sensor Series Line of communicating sensors with backlit display and graphical menus Overview The Allure EC-Smart-Vue Series is designed to interface with Distech

More information

T600HCx-3 Single-Stage Thermostats

T600HCx-3 Single-Stage Thermostats T600HCx-3 Single-Stage Thermostats Installation Instructions T600HCN-3, T600HCP-3 Part No. 24-9890-560, Rev. A Issued June 30, 2014 Applications The T600HCN-3 non-programmable and T600HCP-3 programmable

More information

TDU Series LCD Thermostat For EFCB and EVCB Controllers. Models. Features. Functions. Onboard Sensors. Model # Temp RH CO2 Color.

TDU Series LCD Thermostat For EFCB and EVCB Controllers. Models. Features. Functions. Onboard Sensors. Model # Temp RH CO2 Color. TDU Series LCD Thermostat Models Model # Temp RH CO2 Color TDU10-100 TDU10-101 TDU10-102 TDU10-103 grey LCD white enclosure TDU10 Series Model # Temp RH CO2 Color TDU40-100 TDU40-101 TDU40-102 TDU40-103

More information

Document # R00

Document # R00 Viconics VT7200 Series PIR Ready Zoning Thermostats General The VT7200 series PIR Ready low-voltage microprocessor-based zoning thermostats have been specifically designed to control either 0-10Vdc, staged,

More information

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage s FANs 930, 125 Product/Technical Bulletin S350 Issue Date 0300 The S350A, S351A, and S352A Stage s are intended to be used with System

More information

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH HT-1300 Series Temperature and Humidity Duct Sensor Product Bulletin Specifically designed for HVAC application, the HT-130x-UD1 sensor is a highly accurate and reliable for measuring relative air humidity

More information

Fume Hood Operating Display Panel

Fume Hood Operating Display Panel Desigo TRA Fume Hood Operating Display Panel QMX3.P87 The Operating Display Panel (ODP) is the interface between the operator and the DXR Fume Hood Controller (FHC). LCD display for volume flow setpoint,

More information

Accuracy by Design Products for the HVAC Professional

Accuracy by Design Products for the HVAC Professional Accuracy by Design Products for the HVAC Professional Greystone Energy Systems Inc., is one of North America s largest ISO registered manufacturers of HVAC sensors and transducers for Building Automation

More information

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100 GETTING STARTED GUIDE NI 9217 4 RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100 This document explains how to connect to the NI 9217. Note Before you begin, complete the software and hardware installation

More information

GCS Multipoint Carbon Dioxide Gas Concentration Sampler

GCS Multipoint Carbon Dioxide Gas Concentration Sampler Electronic Control Manual 16 Sensors and Stats Section S Technical Bulletin Issue Date 0101 GCS-000- Multipoint Carbon Dioxide Gas Concentration Sampler Product Overview Page *3 Installation 5 Mounting

More information

TEC1100 Series Thermostat

TEC1100 Series Thermostat Issue Date May 7, 2004 TECHNICAL BULLETIN TEC1100 Series Thermostat Introduction Description In this document, Building Automation System (BAS) is a generic term that refers to the Metasys Network (Network

More information

3M Benchtop Air Ionizer 963E. User s Guide

3M Benchtop Air Ionizer 963E. User s Guide 3M Benchtop Air Ionizer 963E User s Guide 1 Table of Contents Section Page Safety Information...3 1. Description...4 2. Performance...4 3. Power Requirements...4 4. Installation...4 5. Operation...5 6.

More information

T125-E. Electric Fan Coil Thermostat. Product Bulletin. Operation. Appearance. Installation, Service and Maintenance

T125-E. Electric Fan Coil Thermostat. Product Bulletin. Operation. Appearance. Installation, Service and Maintenance T125-E Electric Fan Coil Thermostat Product Bulletin New Generation T125 Electric Fan Coil Thermostats are designed to control heating, cooling, or air conditioning unit in Commercial, Industrial and Residential

More information

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air Document No. 155-755 Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air Description Features Application The Q-Series Relative Humidity and

More information

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification Dual Technology Wall Switch Occupancy Sensor Manual & Specification PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES Douglas Lighting Controls Page 1 November 19, 2014 1. INTRODUCTION

More information

Model SWH-3000 Proximity Multi-Frequency 125KHz & 13.56MHz (Fixed) Reader Installation Guide. Version A0 Part Number UM-102 September 2005

Model SWH-3000 Proximity Multi-Frequency 125KHz & 13.56MHz (Fixed) Reader Installation Guide. Version A0 Part Number UM-102 September 2005 Model SWH-3000 Proximity Multi-Frequency 125KHz & 13.56MHz (Fixed) Reader Installation Guide Version A0 Part Number UM-102 September 2005 1 CONTENTS Introduction................................................

More information

WRS-TTx Series Wireless Room Temperature Sensors

WRS-TTx Series Wireless Room Temperature Sensors WRS-TTx Series Wireless Room Temperature Sensors Installation Instructions WRS-TTP0000-0, WRS-TTR0000-0, WRS-TTS0000-0 WRS-TTP0000-1, WRS-TTR0000-1, WRS-TTS0000-1 4Issued February 20162-10126-19,Rev.HPart

More information

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules FANs 930, 125 Product/Technical Bulletin S350 Issue Date April 8, 2014 System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage s The S350A, S351A, and S352A Stage s are intended to be used

More information

Location Requirements

Location Requirements 24-7701- 136, Rev. B FANs 216, 1628.3 Installation Instructions HH-6705 Issue Date 0316 TRUERH Series HH-6705 Duct Humidistat I nstallation IMPORTANT: Use this HH-6705 Series Duct Humidistat only as an

More information

LORAIN CIP 4890/48120 DC Power System

LORAIN CIP 4890/48120 DC Power System DC Power for Business-Critical Continuity Key Features Compact flexibility provides rectifiers, distribution, and controller in one shelf Constant power delivers more current at lower voltages to meet

More information

Installation and Operation. Tracer ZN521 Zone Controller CNT-SVX07C-EN

Installation and Operation. Tracer ZN521 Zone Controller CNT-SVX07C-EN Installation and Operation Tracer ZN521 Zone Controller CNT-SVX07C-EN Installation and Operation Tracer ZN521 Zone Controller CNT-SVX07C-EN April 2005 CNT-SVX07C-EN Tracer ZN521 Zone Controller Installation

More information

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001 SLATE Base Module R8001A1001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform can

More information

HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide

HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide March 2006 (First Edition) Part Number 413611-001 Copyright 2006 Hewlett-Packard Development Company, L.P. The information

More information

LORAIN CSP DC Power System

LORAIN CSP DC Power System DC Power for Business-Critical Continuity Key Features Compact flexibility provides more space for revenue generating equipment Constant power delivers more current at lower voltages to meet load or recharge

More information

SEE DISCLAIMER ON REVERSE

SEE DISCLAIMER ON REVERSE BOLTEK CORPORATION Lightning Detection GSM-1 Text Message Notification for EFM-100C Electric Field Monitor User Guide SEE DISCLAIMER ON REVERSE BOLTEK LIGHTNING DETECTION GSM-1 Text Message Alert Dialer

More information

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide P/N 1072921 REV A ISS 10FEB15 Contents Product overview 2 Camera description 3 Installation 4 Programming 6 Specifications 7 Setup menu

More information

AS570 Chill-Out Combination Sensor Installation and Operating Instructions

AS570 Chill-Out Combination Sensor Installation and Operating Instructions AS570 Chill-Out Combination Sensor Installation and Operating Instructions Tel: 763. 571.3121 Fax: 763. 571.0927 www.minco.com Description: Model AS570 is a combination sensor, which includes a low-temperature

More information

Model SWH-4000 Multi-Technology Mullion 125 KHz and MHz (Flex) Reader Installation Guide. Version A0 Part Number UM-104 September 2005

Model SWH-4000 Multi-Technology Mullion 125 KHz and MHz (Flex) Reader Installation Guide. Version A0 Part Number UM-104 September 2005 Model SWH-4000 Multi-Technology Mullion 125 KHz and 13.56 MHz (Flex) Reader Installation Guide Version A0 Part Number UM-104 September 2005 1 CONTENTS Introduction................................................

More information

safety & regulatory information

safety & regulatory information safety & regulatory information Document Part Number: 338610-001 Sixth Edition June 2006 This guide provides safety and regulatory information that is compliant with U.S., Canadian, and International regulations.

More information

ETAF Series VDC Fan output LCD Fan Coil Thermostat

ETAF Series VDC Fan output LCD Fan Coil Thermostat ETAF Series 0...10 VDC Fan output LCD Fan Coil Thermostat Features Modern Appearance Stylish rotary dial and buttons Large LCD with backlight 0-10 VDC (2-10 VDC) Fan speed output Retention of temperature

More information

Net/X US32 Universal Setback Communicating Thermostat

Net/X US32 Universal Setback Communicating Thermostat Installation and Programming Instructions for Net/X US32 Universal Setback Communicating Thermostat with Advanced Remote Sensor Bus INTRODUCTION The US32 Communicating Setback Thermostat represents the

More information

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification Dual Technology Wall Mounted Occupancy Sensor Manual & Specification PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES Douglas Lighting Controls Page 1 December 16, 2013 1. INTRODUCTION

More information

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL SECTION 15910 SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division

More information

INSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER

INSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER 273 Branchport Avenue Long Branch, N.J. 07740 (908) 222-6880 INSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER GENERAL: The Series PA-250 and PA-500 Watt Booster Amplifiers are designed

More information

ET10 Series Stand-alone LCD Fan Coil Thermostat

ET10 Series Stand-alone LCD Fan Coil Thermostat ET10 Series Stand-alone LCD Fan Coil Thermostat Features Modern Appearance Stylish Rotary dial and buttons Large LCD with backlight Separate power supply unit with high performance relay outputs Retention

More information

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1 Model TRO24T4XYZ1 Description The TRO24T4XYZ1 is a combination controller and thermostat. The VAV Thermostat Controller is designed for simple and accurate control of any variable air volume box in a number

More information

BAC-4000 Series AppStat

BAC-4000 Series AppStat BAC-4000 Series AppStat Description The KMC AppStat combines the power of a space mounted equipment controller with the convenience of built-in temperature, humidity and motion sensors. The controllers

More information

Installation Instructions. Applications. North American Emissions Compliance. Installation. Part No , Rev. Issued February 8, 2010

Installation Instructions. Applications. North American Emissions Compliance. Installation. Part No , Rev. Issued February 8, 2010 TEC22x6(H)-4 and TEC22x6H-4+PIR Series LONWORKS Network Thermostat Controllers with Dehumidification Capability, Fan Control, and Occupancy Sensing Capability Installation Instructions Part No. 24-9890-1249,

More information

S541.RF 4G Product Guide

S541.RF 4G Product Guide S541.RF 4G Product Guide Table of Contents Table of Contents... Page 1 Overview and General Concept... Page 2 Application... Page 2 Features... Page 3 Specifications... Page 3 Network Topology... Page

More information

Room thermostats with LCD for wall mounting

Room thermostats with LCD for wall mounting s 3 181 RDG100 / RDG110 RDG140 / RDG100 RDG100/H Room thermostats with LCD for wall mounting for fan coil unit applications for universal applications for use with compressors in dx type equipment RDG1

More information

Allure EC-Smart-Air Series Communicating sensors

Allure EC-Smart-Air Series Communicating sensors D a t a s h e e t Allure EC-Smart-Air Series Communicating sensors Overview The Allure EC-Smart-Air Series communicating sensors combine a precise environmental sensing in a discrete and alluring enclosure:

More information

User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens.

User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens. User Guide Luxxor 35 LED Light Source 207 Tremont Street, Rochester, New York 14608 800.536.0790 Fax: 585.235.6645 REV. 0116 gradientlens.com warnings & cautions Warnings & Cautions PORTABLE CAMERA Luxxor

More information

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM 2 Line, 16 Characters/row LCD Display Temperature Input Range -50 C to +500 C -58 F to + 932 F Enclosure NEMA Type 4X Current Rating 30A max (resistive load only) Ambient Temperature -40 C to + 40 C -40

More information

CONTENTS. Installation Guide. VT7200 Series

CONTENTS. Installation Guide. VT7200 Series VT7200 Series Installation Guide For mercial HVAC Applications November 2015 CONTENTS Installation 2 Location 2 Installation 2 Configurable BI/UI inputs overview 4 Network ready 6 Terminal, Identification

More information

T5000 T5000 LCD Digital Fan Coil Thermostat--More Models

T5000 T5000 LCD Digital Fan Coil Thermostat--More Models T5000 T5000 LCD Digital Coil Thermostat--More Models Integrated professional services designed for your unique business need. We care about your business and understand that each business has its unique

More information

T8000 Series T8600 MODBUS Touch Screen Thermostat

T8000 Series T8600 MODBUS Touch Screen Thermostat T8 Series T86 MODUS Touch Screen Thermostat T86 MODUS Series Touch Screen Thermostat Application T86 JS/R Touch screen thermostats are designed to control heating, cooling, or air conditioning unit in

More information

TB7200 Series Communicating Zone Thermostats

TB7200 Series Communicating Zone Thermostats TB7200 Series Communicating Zone Thermostats TB7200 Series Thermostat INSTALLATION INSTRUCTIONS APPLICATION The TB7200 Series PI thermostat family is specifically designed for zoning applications. The

More information

RLD-H10P Refrigerant Leak Detector

RLD-H10P Refrigerant Leak Detector FANs 125, 121 Product/Technical Bulletin RLD-H10P Issue Date 0396 RLD-H10P Refrigerant Leak Detector The RLD-H10P is a professional grade leak detector for use by refrigeration and air conditioning technicians.

More information

RS332N BUTTON OPERATION INTRODUCTION. Installation and Operation Instructions for REMOVING THE THERMOSTAT FROM THE BACKPLATE

RS332N BUTTON OPERATION INTRODUCTION. Installation and Operation Instructions for REMOVING THE THERMOSTAT FROM THE BACKPLATE Installation and Operation Instructions for RS332N 3-Heat / 2-Cool Non-Programmable Setback Thermostat with the Industry s Most Advanced Remote Sensor Bus for Gas, Electric, & Heat Pump Systems www.robertshawclimate.com

More information

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE K3179V2 2/11 Rev. A ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE FEATURES The ADEMCO 4208SNF Universal Class A Module can be used in either of two different applications.

More information

RLD-H10G Refrigerant Leak Detectors

RLD-H10G Refrigerant Leak Detectors FANs 125, 121 Product/Technical Bulletin RLD-H10G Issue Date 0396 RLD-H10G Refrigerant Leak Detectors The RLD-H10G is a professional grade leak detector for use by refrigeration and air conditioning technicians.

More information

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit Instruction Bulletin 63249-420-418A1 02/2014 Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit Commercial Grade with Ground SLSPWD1277C Retain for Future Use INTRODUCTION The Passive Infrared

More information

Light Level Detector, Surface Mount 5754PE. Installation Instructions

Light Level Detector, Surface Mount 5754PE. Installation Instructions Light Level Detector, Surface Mount 5754PE Contents 1.0 Introduction 3 2.0 Safety and Product Handling 3 3.0 Installation 4 3.1 Removing the Top Cover 4 3.2 Installing the Mounting Hardware 4 3.3 Mounting

More information

HEAT COOL. Meets Commercial California Title 24

HEAT COOL. Meets Commercial California Title 24 Digital Thermostat commercial THERMOSTAT T2900 7-DAY MABLE up to 3-heat & 2-cool HEAT COOL HEAT PUMP Control up to 3 Heat & 2 Cool Stages 3 Configurable Outputs Adjustable 2nd & 3rd Stage Timers & Deadbands

More information

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide VT8600 Series Room Controllers TABLE OF CONTENTS Overview 2 VT8600 Rooftop Unit Heat Pump and Indoor Air Quality Controllers 3 VT86X0U5X00B

More information

Predator Controller Hardware Family

Predator Controller Hardware Family Predator Controller Hardware Family Figure1: Predator Controller Only. Figure 2: Predator VAV Actuator. The LONMARK certified configurable Predator Controller provides direct digital control of a variety

More information

Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications

Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications Series P77 Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications Product bulletin These pressure controls are designed for use in a variety of applications involving refrigeration

More information

Isolated Thermocouple Module

Isolated Thermocouple Module User Manual for the HE693THM665, HE693THM666, HE693THM667, HE693THM668 Isolated Thermocouple Module Twelfth Edition 19 April 2004 PREFACE 19 APR 2004 PAGE 3 PREFACE This manual explains how to use the

More information

ALTAIR 5X Multigas Detector Product Specification

ALTAIR 5X Multigas Detector Product Specification ALTAIR 5X Multigas Detector Product Specification PHYSICAL CHARACTERISTICS Gas delivery Size, pumped unit without IR Size, pumped unit with IR Weight Handling Case material Environmental protection Display

More information

York 25-Ton VAV Rooftop Unit

York 25-Ton VAV Rooftop Unit HVAC PRO for Windows User s Manual 637.5 OEM Section Technical Bulletin Issue Date 0996 York 25-Ton VAV Rooftop Unit Introduction Page 3 Overview *3 Configuration 5 Sequence of Operation 7 Modes of Operation

More information