1 Diode-Pumped Solid-State Blue s 58 BLD Series 58 BSD Series Our diode-pumped solid-state blue lasers provide high power output in a compact air-cooled package. They are ideal for use in semiconductor, biomedical, spectroscopic, interferometric, and holographic instrumentation applications; laser display devices; photo-plotters; PC board, wafer, and surface inspection equipment; and particle characterization instrumentation. Other wavelengths are available. Up to 400 mw at 457 nm All solid-state for reliability transverse and longitudinal mode Lightweight and compact Coherence length to eters Spectral line width down to 200 khz Low power consumption Universal power supply RS-232 interface OEM modules available Âμ

2 Specifications: 58 BLD & BSD series Common to All Models Wavelength: nm Output Mode: single transverse mode Beam Quality: M 2 <1.3 Spectral Linewidth (FWHM): BSD Series: <0.5 nm BLD Series: <200 khz single frequency Polarization: Linear (horizontal) >:1 extinction ratio Warm-up Time from Cold Start: <3 minutes Beam Pointing Stability (constant temp.): <25 mrad With Beam Combiner/Expander: <7 mrad Power Stability (8 hours): 83% rms Amplitude Noise BLD Series: <2% (20 Hz to 1 MHz) Number of Beams: 2 (exit angles are not parallel to mechanical center line) Beam Diameter (1/e 2 at waist): Raw Beam: See Table Beam Diameter (1/e 2 ) with Beam Combiner/Expander: Approximately 4! table values Beam Divergence (full angle 1/e 2, ): <5 mrad (each beam) Beam Divergence (full angle 1/e 2, ): <5 mrad vertical (each beam) Beam Divergence () with Beam Combiner/Expander: <0.7 mrad Electrical Parameters Recommended Power Supply: 58 PSM 290 Electrical Service: to 240 Vac, 50 to 60 Hz Power Requirements: 150 W (typical) Cable Length: 36 inches (914 mm) Environmental Specifications Cooling: Forced air-cooled with heat sink Operating Temperature: +10 C to +35 C Storage Temperature: 410 C to +60 C Relative Humidity, Operating: 0 to 95% noncondensing Head Weight: 3.9 kg (8.6 lb) Power Supply Weight: 3.7 kg (8.1 lb) Options Beam combiner/expander 58 ACB 001 OEM module Custom beam delivery Custom configurations CDRH compliance kit LASER RADIATION AVOID EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION CLASS 4 LASER PRODUCT MAXIMUM OUTPUT POWER: 1 WATT AT 457 nm 10 mw AT 914 nm CLASSIFICATION PER EN :1994 Most Melles Griot lasers and instruments are designed, tested, and manufactured for compliance with applicable European electrical and laser safety standards. OUTPUT BEAMS AND POLARIZATION 58 BLD and BSD series lasers have two output beams. In high-power frequency-doubled linear cavities, the forward- and backwardpropagating beams in the nonlinear crystal can generate unwanted effects such as depolarization and astigmatism. To avoid these effects, we separated the forward- and backward- propagating beams. The two beams exit the laser at a slight angle with respect to one another. Each beam is linearly polarized and can be treated optically as emanating from two waists located in the cavity. They can be reimaged into a single spot or used independently. Specifications for 58 BLD and BSD Series Diode-Pumped Solid-State s Model 58 BLD BLD BLD BLD BLD BSD BSD BSD BSD BSD 605 Output Power (mw) Beam Shape (both beams) Beam Dimensions (1/e 2 ; full width at waist) vertical (each beam) 0.15 mm 0.15 mm 0.15 mm 0.15 mm Beam Dimensions (1/e 2 ; full width at waist) horizontal (each beam) 0.29 mm 0.29 mm 0.29 mm 0.29 mm Beam Divergence (full angle 1/e 2, mrad) horizontal (each beam) <2.5 mrad <2.5 mrad <2.5 mrad <2.5 mrad Coherence Length Longitudinal Mode

3 7.50 (190.5) 1 DPSS POWER SUPPLY AND CONTROLLER Enable 4.88 (123.8) Disable Main System Power Fault Emission On Off External Interface RS-232 FRONT VIEW.60 (15.2) (318.5) 11.7 (297.2).24 (6.96) SIDE VIEW dimensions: inches (mm) 58 PSM 290 power supply Select from more than 32 wavelengths Melles Griot manufactures a comprehensive line of lasers and laser systems for laboratory and OEM applications. Standard products include helium neon and helium cadmium lasers, diode-pumped solid-state lasers, argon, krypton, and mixed gas ion lasers, and semiconductor laser assemblies. Available wavelengths range from 325 nm in the ultraviolet to 1.52 mm in the near infrared, with powers from a few milliwatts to several watts, as shown in the chart below. MAXIMUM POWER (mw) 10, WAVELENGTHS (nm) Spectral output available from Melles Griot lasers

4 10.33 (262) 7.15 (182) 4.00 (102) 1.40 (36) 5.00 (127) 5.62 (143) dimensions: inches (mm) 58 BLD and BSD series laser head (top view) 3.95 () 3.20 (81) 1.85 (47) 4.32 (110) 3.60 (91) dimensions: inches (mm) 58 BLD and BSD series laser head (front view) Âμ Group 2051 Palomar Airport Road, 200 Carlsbad, CA (760) FAX (760) Canada (613) France (01) Germany (06251) Japan (03) Netherlands (0316) Singapore Sweden (08) United Kingdom (01353) MELLES GRIOT is a registered trademark of Melles Griot Inc. in the United States and certain other countries. In France, Germany, Italy, Belgium, The Netherlands, and Luxembourg, MELLES GRIOT is a registered trademark of Melles Griot B.V. Melles Griot follows a policy of continuous product development. For this reason, specifications are subject to change without notice. PRINTED IN USA 2001 MELLES GRIOT /01

5 Solid-State Blue System 457 nm, 50 to 400 mw 85 BLS Series Melles Griot blue single beam diode-pumped solid-state blue lasers provide high power output in a compact air-cooled package. They are ideal for use in semiconductor, biomedical, spectroscopic, interferometric, and holographic instrumentation applications; laser display devices; photo-plotters; PC board, wafer, and surface inspection equipment; and particle characterization instrumentation. Other wavelengths are available. Up to 400 mw at 457 nm transverse and longitudinal mode Lightweight and compact Coherence length up to 5 meters output beam Low power consumption Universal input voltage power supply RS-232 interface Automatic power control CDRH and CE compliant Âμ

6 Specifications (Common to All Models) Output Specifications Wavelength: nm Transverse Mode: Longitunital Mode: Beam Quality: M 2 <1.2 Coherence Length: Up to 5 m (ACC mode) Polarization: Horizontal: 85 Extinction Ratio: >:1 Warm-up Time from Cold Start: <5 minutes Beam Pointing Stability ( C): <0.025 mrad With Beam Collimator: <0.007 mrad Power Stability ( C over 8 hours): with Automatic Current Control (ACC): 85% with Automatic Power Control (APC): 82.5% Amplitude Noise (20 Hz to 2 MHz): <2% rms Beam Exit Angle: 4 81 (horizontal) 0 81 (vertical) Beam Diameter (1/e 2 at waist): See Table Below Beam Diameter (1/e 2 ) with Beam Collimator: Approximately 4! table values Beam Divergence: See Table Below Beam Divergence () with Beam Collimator: <1.5 mrad Electrical Specifications Input: to 240 Vac 8 10%, 50 to 60 Hz Power: 150 W (typical) Head Cable Length: 914 mm (36 inches) Environmental Specifications Cooling: Forced-air cooled with heat sink Operating Temperature: +10 C to +35 C Storage Temperature: 410 C to +60 C Relative Humidity, Operating: 0 to 95% noncondensing Head Weight: 3.9 kg (8.6 lb) Power Supply Weight: 3.7 kg (8.1 lb) Options Collimator 58 ASB 001 Custom beam delivery Custom configurations LASER LIGHT AVOID EXPOSURE TO BEAM CLASS IIIb LASER PRODUCT (CDRH) CLASS 3B LASER PRODUCT (EN :1994) <500 mw at 457 nm Melles Griot lasers are designed, tested, and manufactured for compliance with applicable international electrical and laser safety standards. Beam Specifications Model Output Power (mw) Beam Shape Beam Dimensions (1/e 2 ; full width at waist, mm) Vertical/Horizontal Beam Divergence (full angle 1/e 2, mrad) Vertical/Horizontal IEC/CDRH Class 85 BLS BLS BLS BLS / / / /0.29 <5.0/<5.0 <5.0/<5.0 <5.0/<2.5 <5.0/<2.5 3B/IIIb 3B/IIIb 3B/IIIb 3B/IIIb

7 190 (7.50) 1 DPSS POWER SUPPLY AND CONTROLLER Enable 124 (4.88) Disable Main System Power Fault Emission On Off External Interface RS-232 FRONT VIEW 15.2 (.60) 319 (12.6) (11.7) 7.0 (.24) air inlet dimensions: millimeters (inches) 85 BLS series power supply SIDE VIEW Select from more than 36 wavelengths Melles Griot manufactures a comprehensive line of lasers and laser systems for laboratory and OEM applications. Standard products include helium neon and helium cadmium lasers, diode-pumped solid-state lasers, argon, krypton, and mixed gas ion lasers, and semiconductor laser assemblies. Available wavelengths range from 325 nm in the ultraviolet to 1.52 mm in the near infrared, with powers from a few milliwatts to several watts, as shown in the chart below. MAXIMUM POWER (mw) 10, WAVELENGTH (nm) Spectral output available from Melles Griot lasers

8 air outlet 262 (10.33) 182 (7.15) 102 (4.00) 36 (1.40) mechanical axis optical axis (.65) dimensions: millimeters (inches) 127 (5.00) 143 (5.62) 85 BLS series laser head (top view) (3.95) 81 (3.20) 47 (1.85) 110 (4.32) 91 (3.60) 61 (2.00) dimensions: millimeters (inches) 85 BLS series laser head (front view) Âμ Group 2051 Palomar Airport Road, 200 Carlsbad, CA (760) FAX (760) Netherlands (0316) Japan (03) MELLES GRIOT is a registered trademark of Melles Griot Inc. in the United States and certain other countries. In France, Germany, Italy, Belgium, The Netherlands, and Luxembourg, MELLES GRIOT is a registered trademark of Melles Griot B.V. Melles Griot follows a policy of continuous product development. For this reason, specifications are subject to change without notice. PRINTED IN USA 2006 MELLES GRIOT 2788 REV E 4/06

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series COMMERCIAL LASERS 9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series Key Features Diffraction-limited light delivered through fiber termination module Single transverse mode, collimated beam

More information

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers DFB Laser 8165xA Fabry-Perot Lasers Data Sheet Introduction The high power DFB Laser Source modules are best suited for optical amplifier test and DWDM system test applications. The Fabry-Perot Laser Sources

More information

760nm Single mode VCSEL with Peltier Element and Thermistor in TO510

760nm Single mode VCSEL with Peltier Element and Thermistor in TO510 760nm Single mode VCSEL with Peltier Element and Thermistor in TO510 APC11010108xy Features: Laser Enterprise s 760nm VCSELs are designed to meet the requirements for the optical measurement of oxygen

More information

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305 High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305 The new high-power Q305 laser is an expansion of the existing Q-Series that provides a solution for demanding applications requiring faster throughput.

More information

Laser Safety Training

Laser Safety Training Laser Safety Training Department of Environmental Health and Safety July 2014 COURSE CONTENTS Basics of Lasers and Laser Light Laser Beam Injuries Laser Hazard Classes Laser Safety Standards Laser Hazard

More information

3kW 6kW, QUBE Fiber Lasers

3kW 6kW, QUBE Fiber Lasers 3kW 6kW, QUBE Fiber Lasers CONTENTS 1.1 SCOPE 2 1.2 OPTICAL SPECIFICATION 2 1.3 BEAM DELIVERY FIBER SPECIFICATION 3 1.4 SHARE UNITS 3 1.5 ALIGNMENT LASER 3 1.6 POWER DISTRIBUTION 4 1.7 WATER COOLING REQUIREMENTS

More information

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications Description The DFB-XXX-BF-10-EC-Fx-Hx-N126 laser modules are designed for fiber optic sensor applications. The narrow linewidth and the option of using polarization maintaining optical fiber made it specially

More information

Surface Mount 905 nm Pulsed Semiconductor Lasers High Power Laser-Diode Family for Commercial Range Finding

Surface Mount 905 nm Pulsed Semiconductor Lasers High Power Laser-Diode Family for Commercial Range Finding DATASHEET Photon Detection Surface Mount 905 nm Pulsed Semiconductor Lasers Near field profile Key Features Multi cavity lasers concentrate emitting source size Quantum well structure High peak pulsed

More information

NLC 210 Air-Cooled Argon-ion Laser

NLC 210 Air-Cooled Argon-ion Laser NLC 210 Air-Cooled Argon-ion Laser User s Manual Complete with Operating Instructions for the 9470 and 2270 Power Supply TABLE OF CONTENTS CHAPTER 1: INTRODUCTION 1 CHAPTER 2: LASER SAFETY 2 CENTER FOR

More information

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes 113 Sensor SERIES Related Information General terms and conditions... F-7 About laser beam... P.199~ Sensor selection guide... P.1~ General precautions... P.11 PHOTO PHOTO PARTICUR MEASURE ITY panasonic.net/id/pidsx/global

More information

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications Description The DFB-XXX-BF-10-EC-Fx-Hx-N126 laser modules are designed for fiber optic sensor applications. The narrow linewidth and the option of using polarization maintaining optical fiber made it specially

More information

NLC C61 Air-Cooled Argon-ion Laser

NLC C61 Air-Cooled Argon-ion Laser NLC C61 Air-Cooled Argon-ion Laser User s Manual Complete with Operating Instructions for the 9470 and 2270 Power Supply TABLE OF CONTENTS CHAPTER 1: INTRODUCTION 1 CHAPTER 2: LASER SAFETY 2 CENTER FOR

More information

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes 13 Sensor SERIES Related Information General terms and conditions... F-17 About laser beam... P.13~ Sensor selection guide... P.967~ General precautions... P.1 PHOTO PHOTO Conforming to EMC Directive Conforming

More information

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes 1129 PHOTO PHOTO PARTICUR Sensor SERIES Related Information General terms and conditions... F-3 About laser beam... P.193~ guide... P.121~ General precautions... P.19 Conforming to FDA regulations (-11

More information

Description. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1

Description. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1 Description The DFB-1XXX-BF-XX-CW-Fx-Hx-N127 series of Multi-Quantum Well (MQW) Distributed Feedback (DFB) lasers have been designed specifically to satisfy the requirements of the sensor application.

More information

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112) Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112) The spectral range of lasers vary from a few nanometer up to some hundred micrometers and is mostly

More information

CATALOGUE LASER POINTERS

CATALOGUE LASER POINTERS CATALOGUE LASER POINTERS SM.PROX SRL Via della Beverara 13/A - 40131 Bologna - Italy Tel. +39 051 6350755 - Fax +39 051 6353462 Edition October 2014 With the publication of this catalogue all former editions

More information

FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications

FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications The ARCoptix FTIR OEM modules have been developed for system integrators and people looking for a custom FTIR measurement

More information

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore. This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore. Title Study of applying fiber based laser with the primary standard for optical power and improvement of spectral

More information

OWNERS MANUAL OPERATION GUIDE

OWNERS MANUAL OPERATION GUIDE OWNERS MANUAL OPERATION GUIDE Built in Redmond Oregon USA www.laserlinemfg.com P/N 1700-0041 REV. 7.24.17 PRODUCT OVERVIEW The GL1700 Laser Guide was designed from the ground up to provide precise start-stop

More information

Laser Series. Highly Visible Alignment Lasers For Visually Demanding Surfaces

Laser Series. Highly Visible Alignment Lasers For Visually Demanding Surfaces Guideline Laser Series Highly Visible Alignment Lasers For Visually Demanding Surfaces Red / Green long visible lines Equal brightness across length of the line Uniform Line (no fading at ends of the line)

More information

Return loss measurement of fiber optic components

Return loss measurement of fiber optic components Return loss measurement of fiber optic components Solutions Brief 815-1 How the HP 8153A/HP 81534A measure return loss of fiber optic components? The significance of return loss The introduction of new

More information

User Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014)

User Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014) User s Fiberprime, Inc. Portable 4-Channel Laser Source Instrument www.fiberprime.com Tel: 1-613-5964030 Email: info@fiberprime.com Fax: 1-613-8289398 Portable 4-Channel Laser Source Instrument in Small

More information

Understanding total measurement uncertainty in power meters and detectors

Understanding total measurement uncertainty in power meters and detectors Understanding total measurement uncertainty in power meters and detectors Jay Jeong, MKS Instruments. Inc. INTRODUCTION It is important that users of calibrated power meters and detectors understand and

More information

Commissioning of the ASTA Photoinjector Laser System

Commissioning of the ASTA Photoinjector Laser System Commissioning of the ASTA Photoinjector Laser System Jamie Santucci Advanced Accelerator R & D Fermi National Accelerator Laboratory DOE LSO Workshop, September 11, 2013 Outline Fermilab ASTA Photoinjector

More information

G4 Pulsed Fiber Laser

G4 Pulsed Fiber Laser G4 Pulsed Fiber Laser OEM Safety and System Integration Manual Module types C1 and C2 Module type C1 - fitted with IBeam1 delivery optic Module type C2 - fitted with IBeam2 delivery optic 1 1 Preface Definition

More information

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL Phone: (209) 586-022 (800) 545-022 Fax: (209) 586-026 E-Mail: salessupport@olsontech.com www.olsontech.com OTEB-CO-B (No SNMP) Rev. X7 /7/200 SAFETY WARNINGS

More information

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments MADE FOR THE TRADE! professional FIBER OPTIC XL fibertools Series instruments XL fibertools Series Instruments Designed for Fiber Optic Cable Testing. The XL fibertools are designed for the professional

More information

LUXEON S. Philips Lumileds does not recommend staring directly into any LED lamp or luminaire. LUXEON S Photobiological Safety Report

LUXEON S. Philips Lumileds does not recommend staring directly into any LED lamp or luminaire. LUXEON S Photobiological Safety Report LUXEON S Photobiological Safety Report Application Brief AB81 LUXEON S Photobiological Safety Report Introduction Light Emitting Diodes (LEDs) are incoherent, broad-band optical light sources that span

More information

The FEL Facility Optical Diagnostics and FEL Characterization

The FEL Facility Optical Diagnostics and FEL Characterization The FEL Facility Optical Diagnostics and FEL Characterization M. Shinn, C. Behre, S. Benson, J. Coleman, R. Evans, A. Grippo, J. Gubeli, D. Hardy, K. Jordan, G. Neil, S. Zhang G. Williams Jefferson Lab

More information

LUXEON Rebel. Philips Lumileds does not recommend staring directly into any LED lamp or luminaire. LUXEON Rebel Photobiological Safety Report

LUXEON Rebel. Philips Lumileds does not recommend staring directly into any LED lamp or luminaire. LUXEON Rebel Photobiological Safety Report LUXEON Rebel Photobiological Safety Report Application Brief AB60 LUXEON Rebel Photobiological Safety Report Introduction Light Emitting Diodes (LEDs) are incoherent, broad-band optical light sources that

More information

University of California Santa Barbara Department of Chemistry and Biochemistry Optical Characterization Facility. Safe operations manual

University of California Santa Barbara Department of Chemistry and Biochemistry Optical Characterization Facility. Safe operations manual University of California Santa Barbara Department of Chemistry and Biochemistry Optical Characterization Facility Safe operations manual Rev. 1.03 12/02/2002 Introduction The purpose of this document is

More information

G4 Pulsed Fiber Laser

G4 Pulsed Fiber Laser G4 Pulsed Fiber Laser OEM Safety and System Integration Manual Module types B1 and B4 Module type B1 - fitted with ILLK beam delivery optic Module type B4 - fitted with ILOC beam delivery optic 1 1 Preface

More information

GuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces

GuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces Highly Visible Alignment Lasers for Visually Demanding Surfaces The Guideline 2 Range The provides a reliable and robust industrial alignment laser for a wide range applications including the alignment

More information

Customized LIDARs. Research Pollution Climate. Raman, Depolarization, Backscatter, DIAL

Customized LIDARs. Research Pollution Climate. Raman, Depolarization, Backscatter, DIAL Customized LIDARs Research Pollution Climate Raman, Depolarization, Backscatter, DIAL Raymetrics Introduction Raymetrics was founded in 2002 with the aim of manufacturing the highest quality scientific

More information

Customized LIDARs. Research Pollution Climate. Raman, Depolarization, Backscatter, DIAL

Customized LIDARs. Research Pollution Climate. Raman, Depolarization, Backscatter, DIAL Customized LIDARs Research Pollution Climate Raman, Depolarization, Backscatter, DIAL Raymetrics Introduction Raymetrics was founded in 2002 with the aim of manufacturing the highest quality scientific

More information

Important Safety Notice

Important Safety Notice Date: 27 th April 2015 Page 1 of 12 SPI Lasers UK Limited Safety Information High Power OEM Fibre Lasers Important Safety Notice This notice outlines important safety related information and must be read

More information

Laser Collimated Beam Sensor

Laser Collimated Beam Sensor SERIES Laser Collimated Beam Sensor Class 1 Laser Beam Sensor Safe for Your Eyes Marked Conforming to EMC Directive (Excluding LA-C1) Safe Laser Beam This laser collimated beam sensor conforms to the Class

More information

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments MADE FOR THE TRADE! FIBER OPTIC professional XL fibertools Series instruments XL fibertools Series Instruments Designed for Fiber Optic Cable Testing. The XL fibertools are designed for the professional

More information

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800 SENSORS & SYSTEMS Authority in Displacement Measurement CCD-Precision high accuracy and resolution compact sensor design 5 khz frequency N ILD 1800 TRIANGULATOI PRINCIPLE OPTO NCDT Intelligent Laser-Optical

More information

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA MX1A and MX1B: Laser Displacement Detection MX1A and MX1B: Laser Displacement Detection Built-in math capabilities available (MX1B only) Digital display on amplifier; easy setting and monitoring (MX1B

More information

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800 SENSORS & SYSTEMS Authority in Displacement Measurement CCD-Precision high accuracy and resolution compact sensor design 5 khz frequency N ILD 1800 TRIANGULATOI PRINCIPLE OPTO NCDT Intelligent Laser-Optical

More information

Laser retro-reflective photoelectric sensor with polarization filter. Dimensioned drawing

Laser retro-reflective photoelectric sensor with polarization filter. Dimensioned drawing Dimensioned drawing en 1-214/7 5122143 3 Hz.5 26m We reserve the right to make changes DS_PRKL2566P_en_5122143.fm 1-3 V D 2 LS Laser class 1 acc. to EN 6825-1 Polarized retro-reflective photoelectric sensor

More information

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110 TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110 APPLICATION NOTE CC-107 Introduction This purpose of this document is to detail the advanced, state of the art features TSI has incorporated in the design

More information

Analisi del Focus-shift su sorgenti multikw. Luca Porcelluzzi Ophir Spiricon Europe GmbH

Analisi del Focus-shift su sorgenti multikw. Luca Porcelluzzi Ophir Spiricon Europe GmbH Analisi del Focus-shift su sorgenti multikw Luca Porcelluzzi Ophir Spiricon Europe GmbH Content Content Ophir Spiricon Europe GmbH Beam Characterization Applications Summary 2 Ophir Spiricon Europe GmbH

More information

All personnel working in experimental areas at Jefferson Lab must have completed the EH&S Orientation at Jefferson Lab.

All personnel working in experimental areas at Jefferson Lab must have completed the EH&S Orientation at Jefferson Lab. 1. Introduction Room 206A of the Free-electron laser Facility at Jefferson Lab (hereafter referred to as the Drive Laser Enclosure, or DLE) contains a Class IV laser 1 which drives the IR Demo injector

More information

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com Model Infrared Food Thermometer FS-200 Instruction Manual reedinstruments com Table of Contents Safety... 3 Features... 3 Specifications... 4 Instrument Description... 5 Display Description... 5 Operating

More information

Operator s Manual Mephisto Laser

Operator s Manual Mephisto Laser Operator s Manual Mephisto Laser Operator s Manual Mephisto Laser Todd Campus, West of Scotland Science Park, Maryhill Road Glasgow, G20 0XA, Scotland Mephisto Laser Operator s Manual This document is

More information

Laser Distance Sensor Type M Analog-Output

Laser Distance Sensor Type M Analog-Output Laser Distance Sensor Type M Analog-Output Operating Manual Version 2.3, May 2009 ELAG Elektronik AG l Stegackerstrasse 14 l CH-8409 Winterthur Contents 1. Safety 1.1 Laser safety 1.2 Electrical safety

More information

Hazard Analysis, Mitigation, and Operating Procedures for (Laser name) Laser

Hazard Analysis, Mitigation, and Operating Procedures for (Laser name) Laser Hazard Analysis, Mitigation, and Operating Procedures for (Laser name) Laser Prepared by: Date: Rev. 6/24/2016 Page 1 of 6 Table of contents Summary of identified hazards and hazards mitigation: 1. General

More information

Multitel develops components and full instruments for in-vitro and in-vivo diagnostics in the biomedical, food and drug sectors.

Multitel develops components and full instruments for in-vitro and in-vivo diagnostics in the biomedical, food and drug sectors. Biophotonics Multitel develops components and full instruments for in-vitro and in-vivo diagnostics in the biomedical, food and drug sectors. Bio-sensors design Multitel participates to a large panel of

More information

Pre-Installation Manual Vitara Modelocked Ti:Sapphire Laser

Pre-Installation Manual Vitara Modelocked Ti:Sapphire Laser Pre-Installation Manual Vitara Modelocked Ti:Sapphire Laser 5100 Patrick Henry Drive Santa Clara, CA 95054 USA Vitara Pre-Installation Manual This document is copyrighted with all rights reserved. Under

More information

OMA-300 Process Analyzer

OMA-300 Process Analyzer A window into your process since 1994. The OMA Process Analyzer continuously measures chemical concentrations and physical properties that can be correlated from the 200-1100 nm (UV-Vis / SW-NIR) absorbance

More information

North Dakota State University Laser Safety

North Dakota State University Laser Safety North Dakota State University Laser Safety I. Introduction The laser represents a class of light emitting devices with unique characteristics. Some of these characteristics can result in significant hazards.

More information

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS PRODUCT INFORMATION VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS Tunnel sensors EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY

More information

OPERATOR S MANUAL. Infinity Series Ceramic CO2 Laser: Models 15XXSB

OPERATOR S MANUAL. Infinity Series Ceramic CO2 Laser: Models 15XXSB 92-3031 OPERATOR S MANUAL Infinity Series Ceramic CO2 Laser: Models 15XXSB www.iradionlaser.com Table of Contents Table of Contents... 2 Hazard Information... 3 Terms... 3 General Hazards... 4 Label Locations...

More information

LASER SAFETY BARRIER

LASER SAFETY BARRIER LASER SAFETY BARRIER 5' x 6' Portable Laser Barrier No-Trip Base Design High CW and Pulsed Damage Thresholds SB5X6 All Contents Stored In Base OVERVIEW Features Portable 5' x 6' (1.5 m x 1.8 m) Barrier

More information

The Laser System Supervisor (LSS) is John Hansknecht. Extension: 7096

The Laser System Supervisor (LSS) is John Hansknecht.   Extension: 7096 Table of Contents: Section 1 Introduction to LSOP Section 2 Personnel Section 3 Laser inventory Section 4 Laser Hazards & Hazard mitigation Section 5 Laser Environment Section 6 Written Procedures Section

More information

Electro Optical Components, Inc Skylane Boulevard, Santa Rosa, CA Toll Free: 855-EOC

Electro Optical Components, Inc Skylane Boulevard, Santa Rosa, CA Toll Free: 855-EOC Electro Optical Components, Inc. 546 Skylane Boulevard, Santa Rosa, CA 9543 Toll Free: 855-EOC-63 www.eoc-inc.com info@eoc-inc.com PROFILE BEIJING REALLIGHT TECHNOLOGY CO., LTD Address:3rd Floor, #1 Building,

More information

II-VI SUWTECH INC.

II-VI SUWTECH INC. VERSION Add: F, Building 6, Hongcao Road, Shanghai,, China Tel: + 86 - - 68-978 Fax: + 86 - - 68-89 Email: Suwtech.Laser@ii-vi.com Website: www.ii-vi-suwtech.com II-VI SUWTECH INC. www.ii-vi-suwtech.com

More information

All pulses < 4Hz (>0.25sec) BLUE>400mW. As measured under IEC measurement conditions for classification.

All pulses < 4Hz (>0.25sec) BLUE>400mW. As measured under IEC measurement conditions for classification. THUNDERBOLTB NON-INTERLOCKED HOUSING WARNING This unit contains high power laser devices internally. Do not open the laser housing, due to potential exposure to unsafe levels of laser radiation. The laser

More information

UNIVERSAL COMPACT SENSORS

UNIVERSAL COMPACT SENSORS HIGH-PERFORMANCE SENSORS UNIVERSAL COMPACT SENSORS High-resolution sensors with LED or Laser emission Background suppression models ranging from 30 cm to m Polarised retroreflex with operating distance

More information

FOCUS ON LASERS. Philip Campbell RADIATION SAFETY: Principles, Practice, and Emerging Issues March 2018

FOCUS ON LASERS. Philip Campbell RADIATION SAFETY: Principles, Practice, and Emerging Issues March 2018 FOCUS ON LASERS Philip Campbell RADIATION SAFETY: Principles, Practice, and Emerging Issues March 2018 DISCLAIMER This is a very basic training on laser safety. This training will not provide enough information

More information

Laser Use at Subaru Telescope (NAOJ) Laser Safety Policy

Laser Use at Subaru Telescope (NAOJ) Laser Safety Policy Laser Use at Subaru Telescope (NAOJ) Laser Safety Policy 1. Introduction This program applies to all lasers and laser systems operated by Subaru Telescope. This program maintains compliance with ANSI Z136.1-2007

More information

APPLIED. OMA-406R Rackmount Process Analyzer

APPLIED. OMA-406R Rackmount Process Analyzer A window into your process since 1994. The OMA Process Analyzer continuously measures chemical concentrations and physical properties that can be correlated from the 200-1100 nm (UV-Vis / SW-NIR) absorbance

More information

The University of Mississippi BASIC LASER SAFETY

The University of Mississippi BASIC LASER SAFETY The University of Mississippi BASIC LASER SAFETY The Laboratory Services Division(LS) of Facilities Management Course Outline Laser fundamentals Laser theory and operation Components Types of lasers Laser

More information

LM-80V , h V LM-30V h V

LM-80V , h V LM-30V h V Smart QuadSensors Beampositioning with Laserpad, FieldMaster, FieldMaster-GS and Ultima LabMaster Catalog Name Power Aperture Notes Spectral Accuracy For Single Shot Use with Sensor Number (mm) Range (±

More information

Thermopile Sensor TPS 230 / 3365

Thermopile Sensor TPS 230 / 3365 Revision - Date: 2007/11/12 SENSOR SOLUTIONS Introduction PerkinElmer introduces the new TPS 230 as part of the TPS 23x family for low-cost remote temperature measurement applications. It consists of a

More information

The George Washington University. Laser Safety Manual

The George Washington University. Laser Safety Manual The George Washington University Laser Safety Manual Office of Laboratory Safety November 20, 2013 Table of Contents 1. Introduction 2. Scope and Responsibilities 3. Acquisition Procedures 4. Work Practices

More information

Medical Lasers and Laser Safety

Medical Lasers and Laser Safety Medical Lasers and Laser Safety Key Points Lasers & Laser Safety: - Know the three unique characteristics of laser light - Be familiar with the different medical laser technologies - solid, gas, excimer,

More information

in mobility Gentle & precise cleaning of sensitive Very quiet air-cooled system Large operating distance (up to 250 mm) Laser class 4 product

in mobility Gentle & precise cleaning of sensitive Very quiet air-cooled system Large operating distance (up to 250 mm) Laser class 4 product CLEAN-LASERSYSTEME GMBH PRODUCT INFORMATION & TECHNICAL DATA HIT THE SPOT WITH LIGHT. LOW POWER: CL 20BACKPACK ULTRA-MOBILE COMPACT LASER CLEANING 2 Backpack mounted laser - the ultimate in mobility Average

More information

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

Laser Analyzers for NH3 Safety Monitoring and Leak Detection Laser Analyzers for NH3 Safety Monitoring and Leak Detection Boreal s Worldwide Clients Over 450 systems in 42 Countries Holland Belgium France Germany Italy England Scotland Norway Iceland Canada United

More information

UC INSTRUMENTS GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011

UC INSTRUMENTS GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011 UC INSTRUMENTS GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011 GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) UC INSTRUMENTS GM8036

More information

Instruments Designed for POF & Fibre Optic Cable Testing

Instruments Designed for POF & Fibre Optic Cable Testing XL fibertools Series Instruments Designed for POF & Fibre Optic Cable Testing The XL fibertools are designed for the professional to perform installation and maintenance measurements on both Plastic &

More information

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2 H 2 S Ex p Ex d The world s safest continuous H 2 S analyzer. The OMA continuously measures H 2 S concentration using a full-spectrum UV-Vis spectrophotometer, harvesting the power of collateral data to

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61280-1-3 Edition 2.0 2010-03 Fibre optic communication subsystem test procedures Part 1-3: General communication subsystems Central wavelength and spectral width measurement

More information

*For inquiries and questions about lasers, see the Yellow-Page.

*For inquiries and questions about lasers, see the Yellow-Page. 13. Lasers *For inquiries and questions about lasers, see the Yellow-Page. Since lasers have high energy densities, not only the direct but also the scattered light may cause burns, fires or damage to

More information

This slide presentation has been prepared for Temple University Health System and is intended only for use by it s faculty, staff and students.

This slide presentation has been prepared for Temple University Health System and is intended only for use by it s faculty, staff and students. This slide presentation has been prepared for Temple University Health System and is intended only for use by it s faculty, staff and students. All questions pertaining to this presentation should be directed

More information

3R, 3G 5R, 5G Point Laser Levels

3R, 3G 5R, 5G Point Laser Levels 3R, 3G 5R, 5G Point Laser Levels Users Manual December 2018 (English) 2018 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks

More information

Copyright 2017 by Lasermate Group, Inc.. All rights reserved.

Copyright 2017 by Lasermate Group, Inc.. All rights reserved. Copyright 2017 by Lasermate Group, Inc.. All rights reserved. Table of Contents Laser Safety Eyewear Overview 2 How to Choose Your Laser Safety Eyewear...3 How to Read...4 Filter Flashlamp/IPL...5 Frames

More information

Test Report. Report No.: AGC SS01. Attestation of Global Compliance (Shenzhen) Co., Ltd.

Test Report. Report No.: AGC SS01. Attestation of Global Compliance (Shenzhen) Co., Ltd. age 1 of 14 Test Report Report o.: AGC10737170807SS01 RODUCT DESIGATIO : Laser pointer touch pen BRAD AME : /A MODEL AME : MO8097, MO8193 CLIET : Mid Ocean Brands B.V DATE OF ISSUE : Aug.18, 2017 STADARD(S)

More information

Chemistry Instrumental Analysis Lecture 4. Chem 4631

Chemistry Instrumental Analysis Lecture 4. Chem 4631 Chemistry 4631 Instrumental Analysis Lecture 4 Atomic Spectroscopy Atomic Spectroscopy UV to IR Optical spectroscopy are based on: absorption fluorescence phosphorescence scattering emission chemiluminescence

More information

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract FEATURE ARTICLE Technical Reports The PLCA-800 Series Inline Particle Sensor for Chemical Solutions Yoshihito Yuhara Front end process Sensor module Wafer preparation process Film formation Photo lithography

More information

Laser Use Registration & Application (L.U.R.)

Laser Use Registration & Application (L.U.R.) College of Science & Engineering San Francisco State University 1600 Holloway Avenue, TH323 San Francisco, California 94132-4163 (415) 338-6892 FAX (415) 338-6136 L.U.R. # COSE- Laser Use Registration

More information

PURPOSE OF THE PROCEDURE

PURPOSE OF THE PROCEDURE Title: Non-Ionizing Radiation Procedure Effective Date: November 2005 Revision Date: January 13, 2017 Issuing Authority: Responsible Officer: VP, Facilities and Construction Management Director Environmental

More information

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

Erbium-Doped Fiber Amplifier (EDFA) - MW Series Nanovation s MW series of EDFA products is designed for applications in advanced dense wave division multiplexing (DWDM) systems where high performance and reliability are critical. They are available

More information

Laser Safety. The George Washington University Office of Laboratory Safety Ross Hall, Suite B

Laser Safety. The George Washington University Office of Laboratory Safety Ross Hall, Suite B Laser Safety The George Washington University Office of Laboratory Safety Ross Hall, Suite B05 202-994-8258 LASER LASER stands for: Light Amplification by the Stimulated Emission of Radiation Laser Light

More information

Light fright. Improper laser use poses real safety hazards

Light fright. Improper laser use poses real safety hazards Improper laser use poses real safety hazards Light fright by Douglas Nix, C.E.T. Someone once said that the laser is a solution looking for a problem. Since it became a commercial technology in the 1960s,

More information

USER MANUAL. WDM-D15xx.xx. Single Wavelength Add/Drop Module for DWDM

USER MANUAL. WDM-D15xx.xx. Single Wavelength Add/Drop Module for DWDM Rev. 0 USER MANUAL WDM-D15xx.xx Single Wavelength Add/Drop Module for DWDM Network Electronics ASA Thorøya 3204 Sandefjord, Norway Phone: +47 33 48 99 99 Fax: +47 33 48 99 98 e-mail: support@network-electronics.com

More information

Optical Multitester 500 450 OTDR EMEA & APac Edition Issue 1 Page 1 of 10 Description The 450 OTDR is a PC based state-ofthe-art OTDR designed for field applications. It is a dedicated OTDR which offers

More information

Meets all design requirements of U.S.EPA. Double pass optical system for accuracy and sensitivity. Modulated light beam to eliminate interference

Meets all design requirements of U.S.EPA. Double pass optical system for accuracy and sensitivity. Modulated light beam to eliminate interference The Visible Emission Monitor Opacity Meter and/or Dust Concentration Meter U.S.EPA Compliance D-R 281 AV Opacity/Dust Concentration Monitor with dual channel capability The DURAG D-R 281 AV Visible Emission

More information

Title: Laser Safety Effective Date: 9/91 Revision: 2/97 Number of Pages: 7

Title: Laser Safety Effective Date: 9/91 Revision: 2/97 Number of Pages: 7 Environmental Health and Safety Manual Policy Number: EH&S 6-8 Title: Laser Safety Effective Date: 9/91 Revision: 2/97 Number of Pages: 7 PURPOSE: SCOPE: To protect University employees against health

More information

High performance dry leak detectors ASM 182 TD+ ASM 192 T2D+ HELIUM LEAK DETECTORS 297 > 308

High performance dry leak detectors ASM 182 TD+ ASM 192 T2D+ HELIUM LEAK DETECTORS 297 > 308 H E L I U M L E A K D E T E C T O R S High performance dry leak detectors ASM 182 TD+ 297 > 308 The most powerful dry leak detectors on the market to meet demanding clean applications needs : a unique

More information

USER S GUIDE. Please ONLY use manufacture provided transformer

USER S GUIDE. Please ONLY use manufacture provided transformer USER S GUIDE Manufactured by Blisslights Phone: (626) 709-3319 Fax: (626) 205-4013 www.blisslights.com info@blisslights.com Assembled in the United States LASER RADIATION AVOID DIRECT EYE EXPOSURE CLASS

More information

Publication American Institute of Physics. Reprinted with permission.

Publication American Institute of Physics. Reprinted with permission. P2 Publication 2 M. Noorma, P. Kärhä, A. Lamminpää, S. Nevas and E. Ikonen, Characterization of GaAsP trap detector for radiometric measurements in ultraviolet wavelength region, Rev. Sci. Instrum. 76,

More information

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times! USER GUIDE English IMPORTANT PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal. Contents

More information

Modular: available in any length Current monitoring & error detection Wavelengths: from UV to Visible and IR. LOTUS Line lights

Modular: available in any length Current monitoring & error detection Wavelengths: from UV to Visible and IR. LOTUS Line lights Product Overview LED SOLUTIONS COBRA Slim Line lights Intensity: Now up to 2900 klux Design: Slim and compact Field adjustable: focusing distance and diffusers Chip-On-Board: Extreme brightness and high

More information

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web:  - The sensor is designed for frequent washdowns with a corrosion-resistant AISI316L stainless steel case IP69K rated, compliant to test environments like indicated by Diversey and Ecolab. However, all models

More information

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994. A window into your process since 1994. The OMA Process Analyzer continuously measures chemical concentrations and physical properties that can be correlated from the 200-1100 nm (UV-Vis / SW-NIR) absorbance

More information

Solo PIV Nd:YAG Laser System Operator s Manual

Solo PIV Nd:YAG Laser System Operator s Manual Solo PIV Nd:YAG Laser System Operator s Manual January 2005 Part No. 90-1020E Solo PIV Operator s Manual Preface This manual contains information for proper installation and operation of the Solo PIV and

More information