Instruction Manual. DRY-Line DL 56 Prime: DL 112 Prime: DL 180 Prime:

Size: px
Start display at page:

Download "Instruction Manual. DRY-Line DL 56 Prime: DL 112 Prime: DL 180 Prime:"

Transcription

1 VWR INCU-Line, DRY-Line, VENTI-Line Prime Ovens and Incubators Instruction Manual European Catalogue Number(s): INCU-Line IL 56 Prime: IL 112 Prime: IL 180 Prime: DRY-Line DL 56 Prime: DL 112 Prime: DL 180 Prime: VENTI-Line VL 56 Prime: VL 112 Prime: VL 180 Prime: Before using the equipment, please read carefully this instruction manual! Version 1.3 Issued Page 1 / 38

2 Legal Address of Manufacturer Country of origin: Poland Equipment disposal This equipment is marked with the crossed out wheeled bin symbol to indicate that this equipment must not be disposed of with unsorted waste. Instead it's your responsibility to correctly dispose of your equipment at lifecycle -end by handling it over to an authorized facility for separate collection and recycling. It's also your responsibility to decontaminate the equipment in case of biological, chemical and/or radiological contamination, so as to protect from health hazards the persons involved in the disposal and recycling of the equipment. For more information about where you can drop off your waste of equipment, please contact your local dealer from whom you originally purchased this equipment. By doing so, you will help to conserve natural and environmental resources and you will ensure that your equipment is recycled in a manner that protects human health. Thank you! Page 2 / 38

3 Page 3 / 38

4 Page 4 / 38

5 Contents 1 INTENDED USE AND IMPORTANT INFORMATION FOR THE USER PACKAGE CONTENTS BEFORE THE FIRST USE Installation of shelves Wear and tear parts Remarks on the placement of samples Closing the chamber Internal glass door (INCU-Line) DEVICE DESCRIPTION Control panel OPERATING THE DEVICE Turning the unit on/off Stand-by mode Navigation between windows List of symbols Main window Start the program Stop the program End of program MENU ADD, EDIT, VIEW AND DELETE A PROGRAM Types of program Continous work Program options Adding a new program Editing a program Viewing a program Deleting a program SETUP Alarms Setting date and time USB communication settings Language settings Temperature Page 5 / 38

6 9 ALARMS RESUMING OPERATION AFTER A LONGER PERIOD OF TIME CLEANING AND MAINTENANCE OF THE DEVICE Housing cleaning Interior cleaning TROUBLESHOOTING The device is not working Heating is not effective The device is operating too loud Uneven door BASIC CONTROL SOFTWARE PRODUCT IDENTIFICATION LABEL WARRANTY CONDITIONS TECHNICAL DETAILS Drying ovens with natural convection (DL) Drying ovens with forced convection (VL) Incubators with natural convection (IL) Page 6 / 38

7 1 INTENDED USE AND IMPORTANT INFORMATION FOR THE USER The DRY-Line and VENTI-Line drying ovens are designed for all standard drying and tempering tasks as well as sterilizing glassware. They are intended for use in biological, chemical, medical, pharmaceutical and physical laboratories. Any other use is not intended, and can cause damage and be harmful to health. The DRY-Line drying ovens should not, in particular, be used to prepare foods intended for consumption or to sterilize or decontaminate medical products or medical equipment as defined by the Medical Device Directive 93/42/EWG (MDD). The INCU-Line microbiological incubators are designed to cultivate microorganisms at defined temperatures. It can be used e. g. for determining the number of microorganisms through plate count methods or detecting of pathogenic germs in clinical samples or product samples. It is intended for use in laboratories in these sectors: life sciences, clinical medicine, veterinary medicine, the pharmaceutical industry, the food industry, toxicology, and fundamental research into biology and preclinical medicine. Any other use is not intended, and can cause damage and be harmful to health. The INCU-Line incubator should not, in particular, be used to prepare foods intended for consumption or to sterilize or decontaminate medical products or laboratory equipment. To guarantee your security and the longest efficiency of the unit, please comply with the following rules: 1. The unit cannot be installed: outside, in damp places or places which can be easily flooded, near flammable or volatile substances, near acids or in corrosive environments. 2. It is forbidden to: store inflammable or volatile substances inside the unit, touch live parts of the unit operate the unit with wet hands, put water vessels on the unit, climb or put any objects on the unit, overload the shelves ( the maximum load is described in technical data) Page 7 / 38

8 3. You should: place samples in such a way to provide proper air circulation in the chamber open the door for the shortest period of time to reduce temperature fluctuations secure samples from being blown out by the chamber fan e.g powdery samples always check that the doors are closed use only mains with earth to avoid electric shocks, unplug the power cable holding the protective cover and not the cable itself, disconnect the unit from the mains before undertaking any repairs or maintenance works, protect the power cable and the plug from any damage disconnect the power plug before moving the unit, disconnect the power plug if the device will not be used for a long period of time, disconnect the unit and protect it from reconnecting if it has any visual faults. 2 PACKAGE CONTENTS INCU-Line devices are delivered with the following equipment: 56 & 112 Prime: 2 stainless steel wire shelves with set of slides 2 pcs. each, keys to the lock (2pcs.), manufacturer test certificate at 37 C, multilingual instruction manual and Basic Control Software (on CD) for download data from internal memory 180 Prime: 3 stainless steel wire shelves with set of slides 2 pcs. each, keys to the lock (2pcs.), manufacturer test certificate at 37 C, multilingual instruction manual and Basic Control Software (on CD) for download data from internal memory DRY-Line and VENTI-Line devices are delivered with the following equipment: 56 & 112 Prime: 2 stainless steel wire shelves with set of slides 2 pcs. each, keys to the lock (2pcs.), manufacturer test certificate at 105 C, multilingual instruction manual and Basic Control Software (on CD) for download data from internal memory 180 Prime: 3 stainless steel wire shelves with set of slides 2 pcs. each, keys to the lock (2pcs.), manufacturer test certificate at 105 C, multilingual instruction manual and Basic Control Software (on CD) for download data from internal memory Page 8 / 38

9 Additional shelves and a base on castors for 180 Prime models can be ordered separately : Description Quantity Cat. No. Additional stainless steel shelf for 56 liter models Additional stainless steel shelf for 112 liter models Additional stainless steel shelf for 180 liter models Base on castors for 180 liter models, Height 470 mm BEFORE THE FIRST USE On the surface of unit components made of stainless steel, slight discoloration may occur. It is a result of the technologies used in the production of metal sheet in accordance with the requirements of PN-EN standard and it is not a defect of the unit. Upon delivery please check the package visually at the courier s presence. The delivering company bears responsibility for any damage during transport. The place of installation of the unit should meet the following conditions: Ambient temperature +10 C C, The unit has not been designed to work in highly dusty environments The place of installation should be appropriately ventilated according to its size The unit should be put on a hard and stable substrate The unit should be placed at least 100 mm away from the wall The height of the room must be at least 300 mm greater than the height of the unit The unit is not designed to be built-in The place of installation of the unit should contain a mains socket. If you don t comply with the above recommendations, the unit may get broken or it may worsen the technical parameters. The unit has been equipped with leveling feet. Please use them to level the unit after it has been placed in its final location. While operating the unit: the door must be closed the access port must be closed with security cap Page 9 / 38

10 The electric installation should meet the following conditions: The device is powered by AC 230V/50Hz. Please connect it to a socket with ground in order to avoid electric shocks in case of the unit s failure. 3.1 Installation of shelves Perform the following steps to adjust shelf height: ) Install the shelf holder at the selected height by inserting it into proper slots on wall. 2) Install the second shelf holder on the opposite wall. 3) Slide the shelf into the shelf holders. 4) Done! To remove a shelf, perform the above steps in reverse order. To remove the shelf holder from the slots, lift it up and slide it towards the rear of the chamber. Page 10 / 38

11 3.2 Wear and tear parts There are the following wear and tear parts - door gasket. 3.3 Remarks on the placement of samples To provide proper air circulation and stable conditions in which the samples are stored in the chamber, it is necessary to keep the following rules: - the max height of the samples should not exceed 1/3 of the space below the shelves - the samples should be placed in such a way that so that the horizontal surface between the containers does not exceed 1/3 of the width and height of the empty shelf - the space between the samples and between the samples and the wall should be more or less equal The picture below is an example of the placement of samples in the chamber. Front view H Hmax Shelf H Hmax Hmax = 2/3H a u v w x y z b Top view u+v+w > 1/3 a x+y+z > 1/3 b u v w x y z Following the above rules will provide best optimal parameters of temperature stability and uniformity. 3.4 Closing the chamber The door has been equipped with a door handle. To close the door, turn the handle to the vertical position, push the door gently and turn the handle to the horizontal position. Closing the door correctly reduces energy consumption and ensures proper temperature stability and uniformity. 3.5 Internal glass door (INCU-Line) To open or close the internal glass door use the plastic handle installed on the glass. While operating the unit at high temperatures, do not touch the glass door or inner parts of the chamber risk of getting burned. Always use safety gloves to protect yourself. Page 11 / 38

12 4 DEVICE DESCRIPTION 1) Electronic controller with LCD display 2) Air-flap knob 3) USB socket 4) Shelf 5) Temperature sensors 6) Chamber fan (only VL) 7) Internal glass door (only IL) 8) Height adjustable feets 9) RS232 socket (for service only) 10) Socket (for power cable) 11) Main power switch 12) Fuse 13) Fan for controller 14) Entry port (Ø 30mm) on left side 15) Air-flap Page 12 / 38

13 4.1 Control panel The control panel has been equipped with a large LCD display and 5 buttons: ) Alarm signal (red LED) 2) Quick turn on/off button 3) LCD graphical display 8 4) Escape/exit button 5) Down button 6) Up button 7) Enter/accept button 8) USB socket 9) Knob for manual air-flap control (0, 25, 50, 75, 100%) Page 13 / 38

14 5 OPERATING THE DEVICE 5.1 Turning the unit on/off DRY-Line Prime and VENTI-Line Prime Before the first using, it is recommended to heat the chamber (3 hours at 250 C). turn on the unit and set the temperature at 250 C. Then let the unit work for 3 hours. During the heating, the unit is likely to produce a specific smell. When you turn on the device with main switch and the display is unreadable (works only the backlight) turn off the device, wait for about 1 minute and turn on the unit again. Once the device is turned on with the main switch, the display will show the driver and software versions. The next step is peripheral autodiagnostics. If one of the components is damaged, the device stops and an appropriate screen is shown. Next the device operation status screen shows up. The measurement of temperature is calibrated that way it shows real temperature in geometrical center of chamber. If the buttons are illuminated and the display switched off, the key pad is locked. Press and hold the button to onlock. If the main switch is turned on, but the unit is not working, it is in a stand-by mode. Press and hold the button to switch on Stand-by mode The stand-by mode allows to turn the unit on/off quickly. To activate it, press down and hold the button. If a program is active, it will stop once in the stand-by mode. If there is a power shortage while in the stand-by mode, the unit will turn on once the power is resumed. 5.2 Navigation between windows Moving between windows, programming and reading the device operation parameters has been made easier and more convenient thanks to intuitive operation and clear messages. You can control the unit by touching the buttons with your finger. It is not possible to use pens, pencils or any other tools. If you touch a button but can t hear it beep, wait 15 seconds before touching it again. Page 14 / 38

15 Functions of the buttons: Button Main window MENU Setting parameters Entering the MENU (double Exiting the MENU or SUB- Cancelling a setting touch) MENU Setting temperature in a single segment program Scrolling down Setting a parameter or selecting a new parameter Entering Statistics window Scrolling up Setting a parameter or selecting a new parameter Entering ALARMS window (after an alarm has been triggered) Entering a SUB-MENU Confirming a setting 5.3 List of symbols Alarm Clock Delayed start active Door closed Ramp (together with a segment number) Segment (together with a segment number) Heating Door open Loop function Fan (with fan speed in %) only for VL models Main window Overview No program: 4 5 Page 15 / 38

16 Active program: ) Device status 2) Program stage 3) Program name 4) Current date and time 5) Current temperature 6) Set temperature After pressing any button, you are able to see what option a button corresponds to: 7 7) Correspondings menus After pressing the PROF button you are able to see: You can change the parameters while operating the unit after you have chosen the number of segments. After pressing the STATUS button you are able to see: Page 16 / 38

17 1) Current segment 2) Icons with current settings (temperature protection class, fan speed, door close/open) 3) Segment time 4) Program time since launching This window allows you to adjust the fan speed for units with forced air convection (see point 7.2). 5.4 Start the program Follow the procedure to launch a pre-defined program. To add a program, see point 7.3. In the MAIN window press twice to enter the menu. Select Run with. Using and select a program and confirm with. Using and choose start options: - immediately to start the program now - delay to delay the start; using, and enter the delay, - date time using, and set the time and date you want the program to start Page 17 / 38

18 5.5 Stop the program To stop the program: Press twice Select Stop and press Confirm with The program will stop. 5.6 End of program After finishing the program, device will emit sound alarm and will show information on display. 6 MENU To enter the MENU press There are 5 SUB-MENUS: twice. - Run launching a program (see point 5.4) - PROGRAMS adding, editing, viewing and deleting programs (see point 7) - SETUP settings - LOGGER viewing and deleting events from the registry Page 18 / 38

19 - INFO information on firmware 7 ADD, EDIT, VIEW AND DELETE A PROGRAM 7.1 Types of program You can edit up to 3 programs with max three steps (segment + ramp) per program. A segment is a stage of the program when a set temperature is maintained in time. A program can consist of one segment (you can set only temperature and time) or of a few segments with additional parameters (you can set temperature, time and for ex. fan speed). Air-flap opening can be adjusted with the knob on the front panel. Additionally, you can adjust ramps which are parameters of the unit while the set temperature is being achieved. Page 19 / 38

20 In a standard program, the segment time starts being count when the set temperature has been achieved. Examples of programs and settings. Single segment program: Temp. [ C] T1 80% Ambient temp fan power Time [h] Three-segment program with ramps and start delay: Temp. [ C] T2 DELAY. RAMP R1 SEGMENT S1 RAMP R2 SEGMENT S2 RAMP R3 SEGMENT S3 1 hour 2 hours 3 hours 1,5 hour 2 hours 1 hour 2 hours T1 T3 Ambient temp. 100% 70% 50% 10% 100% 100% fan power Time [h] Page 20 / 38

21 7.1.1 Continous work In program options position SEGMENTS should be unmarked. All other parameters should be set By needs (there is no possibility to set the duration of segment). Such program when launched will work all the time (non-stop) keeping the possibility of change the set temperature from the main view. To change set temperature from main view press button and press to confirm. Then with buttons: and change the temperature and press to confirm. To exit press. 7.2 Program options Before setting up a new program, please select the program options first. (MENU) -> PROGRAMS -> add -> PROGRAM -> options Use and to select an option and mark it with. Available options: Segments number of segments in a program (max 3), Ramp Loop number of cycles Fan allows the user to set the fan speed (for units with forced air convection); default setting is 100% 7.3 Adding a new program (MENU) -> PROGRAMS -> add If all available programs have been added, you need to remove a program before adding a new one. Page 21 / 38

22 Before editing a new program you need to select the program options described in point 7.2. When you press to exit the options window, the menu will switch automatically to the editing section (see point 7.4). 7.4 Editing a program (MENU) -> PROGRAMS -> add -> PROGRAM -> edit (MENU) -> PROGRAMS -> list -> PROGRAM -> edit Sample program parameters window: Program name Edited parameter Edited ramp or segment - for example segment no. 1 Permitted range Set value Hints for buttons Use and to select a parameter. Confirm with. The value will flicker. Use and to set the value. Confirm with. If you have entered an incorrect value, you can press down to abort. After you have edited all parameters, press down. You will be asked to confirm the changes. Press down to confirm or to cancel. Page 22 / 38

23 Saving a program Segment parameter Ramp parameter Program parameter Instruction Manual DL, VL, IL Example of editing a program: Type Messages Description Setting number of cycles - Loop function Setting numer of Segments e Setting the achieving time - Ramp Setting fan speed for ramp - Ramp and Fan options Setting temperature Setting segment time Segments option Setting fan speed for segment Fan option Allows to confirm saving the changes Information that a program has been saved When you quit program editing, you will see the following window where you can set the temperature of temperature protection. Page 23 / 38

24 The unit is factory equipped with over temperature samples protection, which is realized on the basis of temperature value measured on the second, independent temperature sensor (protection sensor). The purpose of samples protection is to protect from uncontrolled raise or drops of the temperature. At the time of operation, the transmitter disconnects the power supply circuit. Class 3.1 (IL, VL, DL) over temperature protection automatic switch on the circuit when the temperature go down below the set value protection. Over temperature protection class 3.1 according to DIN 12880: T_prot_Hi During setting the value of protection, please note that when achieving the temperature and after opening the door the set temperature may exceed by 2%. If the temperature value of protection will be set to close to set temperature in program, it may cause unexpected activation of the protection. It s recommended to set the values to: - over temperature protection: 10 C above set temperature The activation of protection generates audible alarm and display the alarm icon. 7.5 Viewing a program (MENU) -> PROGRAMS -> list -> PROGRAM -> view After this option has been selected, you can view all the parameters of the program. 7.6 Deleting a program (MENU) -> PROGRAMS -> list -> PROGRAM -> erase Page 24 / 38

25 This option allows you to delete a program. If the program you are going to delete is active, you need to stop it first before deleting it. Press down to delete or to abort.. 8 SETUP The SETTINGS menu allows you to edit some parameters. 8.1 Alarms (MENU) -> SETUP -> Alarms Temp. T_prot_Hi Alarm T_prot_Hi Alarm TEMP HI Example 1 Example 2 T1 TEMP HI TEMP LO Alarm TEMP LO Time You can set range of low and high temperature alarms (TEMO LO and TEMP HIGH) from 0 up 5,0 C. If the device reaches set temperature and for some reason temperature inside the chamber increases or decreases beyond the set offset_t, an audible alarm goes off and the screen shows a warning. The unit has been equipped with a door alarm. You can switch this function off or choose the alarm delay in Settings / Alarms: <off> - door alarm disabled <1> to <5> minutes - alarm delay in minutes Page 25 / 38

26 When the door has been closed, the alarm will be reset. When you confirm the alarm with a button, the door alarm will go off again after the alarm delay time has passed. 8.2 Setting date and time (MENU) -> SETUP -> Clock Use and to switch between editing time and date. Your selection will be framed. Press down. The edited section will illuminate. Use and to set the value and confrim with. You can edit the next section if you press down again. Time and date settings will save automatically when you exit the window after pressing down. 8.3 USB communication settings (MENU) -> SETUP -> Communication In the Communication menu you can set USB transmission parameters (e.g. for connecting a PC or printer). The following options are available: o Port the following parameters can be set: Baudrate Databits (5-8bits) Parity Stopbits The connection parameters in the unit must match the parameters set on an external device.. o Protocol Basic Control type of protocol used for transmission None no transmission Basic Control - protocol provides the communication of the unit with Basic Control Page 26 / 38

27 o o Text data sent as text, used e.g. for printers Printer-txt Service protocols used by service engineers Address determines d unit's address when using ModbusRTU/ASCII and Basic Control protocols Interval determines how often the data is sent through the port 8.4 Language settings (MENU) -> SETUP -> Language Choosing the language in which all the messages are presented. 8.5 Temperature (MENU) -> SETTINGS -> Temperature Scale You can display temperature at ºC or ºF. Offset It allows you to correct the temperature indicated on the display by adding the correction value. The set correction value is taken in the whole temperature range operation of the device. For example, if the average temperature displayed by the device indicates 100 C and the average temperature measured by independent, external sensor indicates 100,5 C, the correction should be set on +0,5 C. The average temperature should be calculated from chosen period of time e.g 30min. EVENTSLOG (MENU) -> EVENTSLOG The following events are registered: starting a programme, stopping a programme, end of a programme, turning on power, Page 27 / 38

28 Door open, Door closed, turning off power Events are registered chronologically and you can view them using the view option. In the top left corner on the display, there is the event s number, as well as the total number of all events. Using the and you can scroll the events. Press down to exit the registry.you can also delete events. To delete, choose the erase option and confirm with. Measurement data in the registry. You can record the data at specified interval. To delete all data from registry, choose erase and confirm with. Sample temperatures stored in the internal memory can be downloaded to your computer using free program Basic Control. Downloaded data can be saved in.txt or.csv format. 9 ALARMS If an alarm has been triggered, you will hear a sound signal, the red LED will switch on and the following icon will be displayed. If you press down twice, you will be directed to the events log. To delete the alarm message press down gone, the alarm will be triggered again. If the cause of the alarm has not Page 28 / 38

29 The messages below may appear in the alarm window. Message Temperature LO Cause of the message Temperature offset alarm (see point 8.1) temperature too low Program continues only after the error has been eliminated YES Temperature HI Temperature offset alarm (see point 8.1) temperature too high YES CH1-error Measurement channel error (malfunction of main temperature sensor or measuring system) YES Door open Door open longer than the value set in door alarm program continues 10 RESUMING OPERATION AFTER A LONGER PERIOD OF TIME 1. Remove all objects from the chamber. 2. Disconnect the device from the mains 3. Clean and dry the chamber. 4. Leave the door open to avoid nasty smells. 5. Store in temperature between 0 C and 50 C and relative humidity maximum 70%. 11 CLEANING AND MAINTENANCE OF THE DEVICE Before cleaning the device, it needs to be disconnected from the electrical supply! Always use safety gloves while cleaning to avoid the risk of injury due to any sharp edges. Page 29 / 38

30 To clean products made of stainless steel we recommend using cleaning solution dedicated particularly to stainless steel material. It preserves the steel surface from permanent stains and at the same time retains aesthetic appearance of the product. INOX products are manufactured with stainless steel. When used in standard laboratory conditions they do not rust. However it is possible that stains (which may look like rust) form on the steel surface (e.g. due to the kind of samples that are incubated in the chamber). In such case we recommend using cleaning solution (to clean the stains) which is dedicated to this particular application, e.g. Pelox. When cleaning stainless steel product with dedicated cleaning solution, one should pay attention to the suggestions and recommendations given in the user manual (or in the safety data sheet) of the cleaning solution Housing cleaning 1. The housing of the device should be cleaned at least once a week, depending on the working conditions. 2. The housing and door should be cleaned with caution using a soft cloth dampened with water. 3. Only mild cleaning products should be used to clean the device. 4. Electrical parts should not get in contact with water or detergent Interior cleaning 1. The chamber should be emptied of any samples before cleaning. 2. Open the door of the device and wait till the chamber has cooled down, take out the shelves and start cleaning the device, 3. Only water or water with mild detergent should be used Having finished cleaning, you should allow the device to dry fully and fit all parts removed before cleaning. During cleaning you should make sure not to damage the temperature sensor built in on the top of the chamber. In drying oven could happened the internal bottom metal part becomes discoloured. It is caused be very high heaters temperature which are placed just under bottom metal part. Page 30 / 38

31 12 TROUBLESHOOTING 12.1 The device is not working You should check if: 1. There is not an electrical supply failure? 2. The power cord is plugged in the main socket properly? 3. The fuse has not been blown? 4. The power cord has not been damaged? 5. When you turn on the device with main switch and the display is unreadable (works only the backlight) turn off the device, wait for about 1 minute and turn on the unit again Heating is not effective You should check if: 1. Is the door shut tight? Is access ports for external sensors is sealed? 2. Is the air fan switched on (for VL devices)? 3. What is the ambient temperature? 12.3 The device is operating too loud You should check if: 1. Is the device not leaning against furniture or other objects? 2. Is the device levelled properly? 12.4 Uneven door You should check if: 1. the unit has been levelled property? 2. If after levelling the unit the door is still uneven, please contact our service. Page 31 / 38

32 13 BASIC CONTROL SOFTWARE Data from test results memory can be downloaded to PC by BASIC CONTROL software with instruction manual located on supplied CD. To do this: 1. Install BASIC CONTROL software and launch it. 2. Connect device to PC using USB port in the device and computer (using appropriate USB cable). 3. In menu SETUP, choose COMUNICATION à USB port and choose BASIC CONTROL. During the first connection, PC will automatically install the driver support. 4. In program BASIC CONTROL, select CONNECT and specify COM port to which the device is connected. By clicking ACCEPT, the connection will be established. 5. When you choose DOWNLOAD, the data will be downloaded from device memory to PC. The data will be shown on the screen in a table form. 6. Data can be exported to test file or *.csv 7. Message No data registration means that the memory in the device is empty. The data was erased or the interval was set on so high value, data has not been stored yet. To break the connection, choose DISCONNECT. Page 32 / 38

33 14 PRODUCT IDENTIFICATION LABEL The product identification label is located in the upper left corner. Below there is an example of rating plate: Logo 2. Type of device 3. Catalogue number 4. Serial number 5. CE mark 6. Name and address of manufacturer Page 33 / 38

34 15 WARRANTY CONDITIONS VWR International warrants that this product will be free from defects in material and workmanship for a period of two (2) years from date of delivery. If a defect is present, VWR will, at its option and cost, repair, replace, or refund the purchase price of this product to the customer, provided it is returned during the warranty period. This warranty does not apply if the product has been damaged by accident, abuse, misuse, or misapplication, or from ordinary wear and tear. If the required maintenance and inspection services are not performed according to the manuals and any local regulations, such warranty turns invalid, except to the extent, the defect of the product is not due to such non-performance. Items being returned must be insured by the customer against possible damage or loss. This warranty shall be limited to the aforementioned remedies. IT IS EXPRESSLY AGREED THAT THIS WARRANTY WILL BE IN LIEU OF ALL WARRANTIES OF FITNESS AND IN LIEU OF THE WARRANTY OF MERCHANTABILITY. Compliance with local laws and regulations The customer is responsible for applying for and obtaining the necessary regulatory approvals or other authorizations necessary to run or use the Product in its local environment. VWR will not be held liable for any related omission or for not obtaining the required approval or authorization, unless any refusal is due to a defect of the product. Before you contact service: Turn the unit off and on again to make sure it is not working properly. If this is the case, disconnect the unit from the mains and repeat the procedure after an hour (See Troubleshooting chapter) Technical service Visit the VWR s website at for: Complete technical service contact information Access to VWR s Online Catalogue, and information about accessories and related products Additional product information and special offers Contact us For information or technical assistance contact your local VWR representative or visit. Page 34 / 38

35 16 TECHNICAL DETAILS The technical data allows for ± 5% tolerance Drying ovens with natural convection (DL) PARAMETER DL 56 DL 112 DL 180 Chamber capacity [l] Temperature range [ o C] Air convection Interior Housing natural stainless steel power coated sheet Overall dimensions 1) [mm] width height depth Internal dimensions [mm] width Temperature variation (spatial) 2) 3) at 150 o C [ o C] Temperature fluctuation (time) 2) 4) at 150 o C [ o C] height depth /-3,3 +/-3,0 +/-3,5 +/-0,4 +/-0,4 +/-0,4 Nominal power [W] Voltage 50/60 Hz [V] Net weight [kg] Shelves fitted / max 2/5 2/7 3/9 Max shelf workload [kg] Max unit workload [kg] ) dimensions of door handle, power cable and height adjustable feet are not included 2) for measurements performed with a closed air-flap 3) variation (K) calculated for chamber as K = +/ T maks T min 4) fluctuation measured in centre of chamber 2 Page 35 / 38

36 16.2 Drying ovens with forced convection (VL) PARAMETER VL 56 VL 112 VL 180 Chamber capacity [l] Temperature range [ o C] Air convection Interior Housing forced stainless steel power coated sheet Overall dimensions 1) [mm] width height depth Internal dimensions [mm] width Temperature variation (spatial) 2) 3) at 150 o C [ o C] Temperature fluctuation (time) 2) 4) at 150 o C [ o C] height depth /-2,0 +/-2,3 +/-2,5 +/-0,2 +/-0,2 +/-0,2 Nominal power [W] Voltage 50/60 Hz [V] Net weight [kg] Shelves fitted / max 2/5 2/7 3/9 Max shelf workload [kg] Max unit workload [kg] ) dimensions of door handle, power cable and height adjustable feet are not included 2) for measurements performed with a closed air-flap 3) variation (K) calculated for chamber as K = +/ T maks T min 4) fluctuation measured in centre of chamber 2 Page 36 / 38

37 16.3 Incubators with natural convection (IL) PARAMETER IL 56 IL 112 IL 180 Chamber capacity [l] Temperature range Air convection Interior Housing +5 o C above ambient temperature +100 o C natural stainless steel power coated sheet Overall dimensions 1) [mm] width height depth Internal dimensions [mm] width Temperature variation (spatial) 2) 3) at 37 o C [ o C] Temperature fluctuation (time) 2) 4) at 37 o C [ o C] height depth /-0,7 +/-0,6 +/-0,8 +/-0,2 +/-0,2 +/-0,2 Nominal power [W] Voltage 50/60 Hz [V] Net weight [kg] Shelves fitted / max 2/5 2/7 3/9 Max shelf workload [kg] Max unit workload [kg] ) dimensions of door handle, power cable and height adjustable feet are not included 2) for measurements performed with a closed air-flap 3) variation (K) calculated for chamber as K = +/ T maks T min 4) fluctuation measured in centre of chamber 2 Page 37 / 38

38 Page 38 / 38

VWR INCU-Line Peltier Cooled Incubators. Instruction Manual

VWR INCU-Line Peltier Cooled Incubators. Instruction Manual VWR INCU-Line Peltier Cooled Incubators Instruction Manual European Catalogue Numbers: INCU-Line IL 56PR: 390-1031 INCU-Line IL 112PR: 390-1032 INCU-Line IL 240PR: 390-1033 Before using the equipment,

More information

INSTRUCTION MANUAL. Matos Refrigerators / Freezers

INSTRUCTION MANUAL. Matos Refrigerators / Freezers INSTRUCTION MANUAL Matos Refrigerators / Freezers Available Models Matos 68 R, Matos 150 R, Matos 200 R, Matos 250 R, Matos 300 R, Matos 493 R, Matos 625 R, Matos 1365 R, Matos 1460 R Matos 85 F, Matos

More information

Caution: Before using the device first read carefully this manual!

Caution: Before using the device first read carefully this manual! INSTRUCTION MANUAL Drying oven (STD version) Incubator (STD version) Sterilizer (STD version) Cooled incubator (STD version) SLW 15, 32, 53, 115, 240, 400, 750, 1000 SLN 15, 32, 53, 115, 240 CLW 15, 32,

More information

Refrigerated Incubator Model and Operating Instructions

Refrigerated Incubator Model and Operating Instructions Refrigerated Incubator Model 165000 and 165000-2 Operating Instructions N2400379 - Rev. 1 08May2018 1 Contents 1. SAFETY...3 1.1. EMF INTERFERENCE...4 1. PRODUCT INFORMATION...5 1.1 INTRODUCTION...5 2.

More information

Operation Manual. (Version 1.5.1)

Operation Manual. (Version 1.5.1) VWR symphony TM Gravity Convection General Incubator Operation Manual (Version 1.5.1) VWR symphony Gravity Convection General Incubator 414004-610, 414004-612, 414004-614, 414004-616 414004-611, 414004-613,

More information

Caution: Before using the device first read carefully this manual!

Caution: Before using the device first read carefully this manual! INSTRUCTION MANUAL Thermostatic cabinets models: ST BASIC, ST COMF, ST COMF/S, ST PREM, ST PREM/S Laboratory Refrigerators models: CHL BASIC, CHL COMF, CHL COMF/S, CHL PREM, CHL PREM/S Laboratory Freezers

More information

Drying oven VWR DRY-Line with Natural Convection DL 53, DL 115

Drying oven VWR DRY-Line with Natural Convection DL 53, DL 115 Drying oven VWR DRY-Line with Natural Convection DL 53, DL 115 User Manual Issue 11-2015_en valid from device serial number 15-03000 DRY-Line DL 11-2015_en page 2/39 DRY-Line DL 11-2015_en page 3/39 Content

More information

Operation Manual (Version 1.5.1)

Operation Manual (Version 1.5.1) VWR symphony TM Low-Temp./BOD Incubator Operation Manual (Version 1.5.1) VWR symphony Low-Temp./BOD Incubator 414004-626, 414004-628, 414004-630, 414004-632 414004-627, 414004-629, 414004-631, 414004-633

More information

Operator s Manual. Histology Bath

Operator s Manual. Histology Bath Operator s Manual Histology Bath 110-827 05.09.12 Table of Contents Introduction... 2 General Safety Information... 2 Safety Recommendations... 3 Unpacking Your Histology Bath...4 Contents...4 Components

More information

Instruction Manual. Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV

Instruction Manual. Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV Instruction Manual Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV2 9296050000 About This Manual This manual is designed to assist you in optimal usage of your

More information

Drying ovens, incubators, cooled incubators

Drying ovens, incubators, cooled incubators rying ovens, incubators, cooled incubators rying ovens, incubators, cooled incubators All the units in the ST version are equipped with a PI microprocessor controller with an LC graphic display and illuminated

More information

OPERATION MANUAL. StableTemp Economy Mechanical Convection Oven. Model : ,-90,-91,-92,-93,-94

OPERATION MANUAL. StableTemp Economy Mechanical Convection Oven. Model : ,-90,-91,-92,-93,-94 OPERATION MANUAL StableTemp Economy Mechanical Convection Oven Model : 52412-89,-90,-91,-92,-93,-94 This operation manual describes the important subjects on maintaining the product s functions, safety,

More information

Manual v1 Page 1 of 19. Manual. Laboratory autoclave

Manual v1 Page 1 of 19. Manual. Laboratory autoclave Manual 20.2.2015 v1 Page 1 of 19 Manual Laboratory autoclave Autoclave using steam for the treatment of material and laboratory processes e.g. sterilization, as an aid in research and development CertoClav

More information

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers Laboratory incubators (CL) and drying ovens (SL)

More information

TTT Digital Incubator

TTT Digital Incubator TTT Digital Incubator 135000 135000-2 Operating Instructions N2400342 Rev. 1 08/13 Table of Contents 1.0 Safety... 3 2.0 Intended Use of Product... 4 3.0 Installation... 4 3.1 Unpacking the Unit... 4 3.2

More information

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA Operating Instructions High Performance Refrigerator PR-L2466W- PA PR-L2466W-PA Please read these instructions carefully before using this product, and save this manual for future use. See page 11 for

More information

Laboratory thermostatic chambers

Laboratory thermostatic chambers Laboratory thermostatic chambers I Laboratory thermostatic chambers Thermostatic cabinets single chamber double chamber Laboratory refrigerators single chamber double chamber Thermostatic boxes Laboratory

More information

Caution: Before using the device first read carefully this manual!

Caution: Before using the device first read carefully this manual! INSTRUCTION MANUAL Drying oven (STD version) Incubator (STD version) Sterilizer (STD version) Cooled incubator (STD version) SLW 15, 32, 53, 75, 115, 180, 240, 400, 750, 1000 SLN 15, 32, 53, 75, 115, 180,

More information

Operating instructions Page 12

Operating instructions Page 12 Operating instructions Page 12 Refrigerator with explosion-proof interior container Read the operating instructions before switching on for the first time 7082 271-00 LKEXv 910 Disposal notes The appliance

More information

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time Operating instructions Page 14 Refrigerator Read the operating instructions before switching on for the first time 7085 039-00 LKv 5710 Content Disposal notes... 14 Description of the appliance... 14 Safety

More information

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL The THL2 is compatible with computers using Windows 2000, XP, Vista, Windows 7 and Windows 8. INSTRUCTION MANUAL 2 THL2 1-800-547-5740 Fax: (503) 643-6322 www.ueitest.com email: info@ueitest.com Temperature/Humidity

More information

Digital 7 Square Plate Magnetic Stirrer

Digital 7 Square Plate Magnetic Stirrer Digital 7 Square (Hotplate) Magnetic Stirrer User Manual MS7-Pro Digital 7 Square Plate Magnetic Stirrer MS7-H550-Pro Digital 7 Square Hotplate Magnetic Stirrer Please read the User Manual carefully before

More information

Oakton TEMP 9500 Advanced Multiparameter Controller

Oakton TEMP 9500 Advanced Multiparameter Controller Oakton TEMP 9500 Advanced Multiparameter Controller Models: 89800-03 & 89800-04 Oakton Instruments 625 E Bunker Ct. Vernon Hills, IL 60061, USA 1-888-4OAKTON (1-888-462-5866) info@4oakton.com Contents

More information

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1 Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com INSTRUCTION MANUAL THL1 Introduction C o n t rols and Indicators Use the UEi THL1 to log temperature

More information

Laboratory refrigerators

Laboratory refrigerators Laboratory refrigerators Application storage of water and sewage samples, piezometer leachate storage of AAS, GC or HPLC calibration standards storage of reagents chemical storage storage of medicines

More information

User Manual. MS7-H550-Pro MS7-H550-S MS7-Pro MS7-S

User Manual. MS7-H550-Pro MS7-H550-S MS7-Pro MS7-S User Manual MS7-H550-Pro MS7-H550-S MS7-Pro MS7-S LCD Digital 7 Square Hotplate Magnetic Stirrer LED Digital 7 Square Hotplate Magnetic Stirrer LCD Digital 7 Square Plate Magnetic Stirrer Classic 7 Square

More information

Operation Manual. VWR Vacuum Ovens. (Version 2.0.0) VWR Vacuum Oven , , , ,

Operation Manual. VWR Vacuum Ovens. (Version 2.0.0) VWR Vacuum Oven , , , , VWR Vacuum Ovens Operation Manual (Version 2.0.0) VWR Vacuum Oven 10752-398, 10752-400, 10752-402 10752-404, 10752-354, 10752-356 10752-402 VWR Vacuum Oven, 30Lit. Man. V205 (10 Nov. 2015) Contents Page

More information

ec Preheater User Manual

ec Preheater User Manual ec Preheater DOC.ID: ec 004 999_R02 01 12 2015 www.eurocircuits.com 1 Table of Contents: Application of this device 4 Specifications 5 Declaration of compliance 6 Safety precautions 7 Parts of the device

More information

Watchguard WGAP864 User Manual

Watchguard WGAP864 User Manual Watchguard WGAP864 User Manual v1.0 Issued September 2016 1 2 Table of Contents Glossary... 5 1. Introduction to your Watchguard WGAP864... 6 2. Before Operating your Alarm System... 6 3. Understanding

More information

HOBO U14 Data Logger User Manual

HOBO U14 Data Logger User Manual HOBO U14 Data Logger User Manual The U family of data loggers offers reliability and convenient monitoring for applications that require higher accuracy, better resolution, more memory, or USB connectivity

More information

USER MANUAL. ITAG 4 / ITAG 4 Bio/ ITAG 4 TH DATA LOGGER. UM-ITAG REV.B 03/02/2016

USER MANUAL. ITAG 4 / ITAG 4 Bio/ ITAG 4 TH DATA LOGGER. UM-ITAG REV.B 03/02/2016 USER MANUAL EN ITAG 4 / ITAG 4 Bio/ ITAG 4 TH DATA LOGGER Updated@ 03/02/2016 CONTENTS Product Overview... 3 Logger... 3 LCD... 4 Technical Specifications... 5 TEMPCENTRE SOFTWARE... 6 How to download

More information

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual This owner s manual provides instructions on safe installation use, and troubleshooting assistance. Please read it carefully and save it for reference

More information

Instruction Manual for the Revolutionary Science RS-IF-203 Incufridge

Instruction Manual for the Revolutionary Science RS-IF-203 Incufridge Instruction Manual for the Revolutionary Science RS-IF-203 Incufridge REVOLUTIO NARY SCIENCE Manufacturer of Precision Laboratory Equipment Table of Contents Introduction 2 Recommended Safeguards 3 Operating

More information

Operator s Manual. IP-100 Immersion Probe Cooler

Operator s Manual. IP-100 Immersion Probe Cooler Operator s Manual IP-100 Immersion Probe Cooler 110-810 04.27.11 Table of Contents Introduction... 3 General Information... 3 General Safety Information... 3 Safety Recommendations... 4 Unpacking Your

More information

Table of Contents DIGITAL DRYING OVEN. Features. Setup. Cautions. Description of the parts. Temperature Controls. Maintenance and Storage

Table of Contents DIGITAL DRYING OVEN. Features. Setup. Cautions. Description of the parts. Temperature Controls. Maintenance and Storage Table of Contents 1 Features 2 Setup 3 Cautions 4 Description of the parts 5 Temperature Controls 6 Maintenance and Storage 7 Troubleshooting 8 Warranty 9 Technical Specifications -2- Safety warnings Before

More information

Reacti-Therm I and III Heating Modules

Reacti-Therm I and III Heating Modules INSTRUCTIONS Reacti-Therm I and III Heating Modules TS-18822 TS-18824 Number TS-18822 TS-18824 Description Reacti-Therm I Heating Module (single block) Reacti-Therm III Heating Module (triple block) 2101.1

More information

FF820 freestanding full height larder fridge Manual for Installation, Use and Maintenance

FF820 freestanding full height larder fridge Manual for Installation, Use and Maintenance FF820 freestanding full height larder fridge Manual for Installation, Use and Maintenance 1 Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949

More information

FF820 Freestanding Full Height Larder Fridge Manual for Installation, Use and Maintenance

FF820 Freestanding Full Height Larder Fridge Manual for Installation, Use and Maintenance FF820 Freestanding Full Height Larder Fridge Manual for Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949

More information

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor The BINDER CB series CO 2 incubator is the premium class among the CO 2 incubators. It is suitable for all sensitive

More information

User Manual. Dryer Controller M720

User Manual. Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 1.00 Software version 1.00 Preliminary version Manual M720 Dryer controller Page 1 of 42 Document history Preliminary version: - Created in April, 2009

More information

Follett Performance Plus

Follett Performance Plus Follett Performance Plus touchscreen user guide The next level of control in undercounter refrigeration Controller Operation - Performance Plus touchscreen Use and care of the LCD Performance Plus touchscreen

More information

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs User Manual Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs Models 89800-03 and 89800-04 THE STANDARD IN PRECISION MEASUREMENT Table of Contents

More information

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min

More information

Undercounter Refrigerator Operation Manual i.series and Horizon Series

Undercounter Refrigerator Operation Manual i.series and Horizon Series Undercounter Refrigerator Operation Manual i.series and Horizon Series Blood Bank Models i.series: ib105 (Version B) Horizon Series: HB105 (Version B) Laboratory/Pharmacy Models i.series: ilr105 (Version

More information

Digital Heat Block User Manual

Digital Heat Block User Manual Digital Heat Block User Manual Quidel Digital Heat Block Page 1 of 10 General Information Quidel Contact Information Contact Quidel Technical Support from 8:00 a.m. to 5:00 p.m. EST Tel: 800.874.1517 (in

More information

Operator s Manual. The Bullet Blender 50 BB50-AU, BB50-DX. Contents. Congratulations!

Operator s Manual. The Bullet Blender 50 BB50-AU, BB50-DX. Contents. Congratulations! Operator s Manual The Bullet Blender 50 BB50-AU, BB50-DX Congratulations! Congratulations on your purchase of a Bullet Blender 50 by Next Advance, Inc., for mixing, lysing, disrupting, and homogenizing

More information

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs User Manual Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs Models 89800-13 and 89800-14 THE STANDARD IN PRECISION MEASUREMENT Table of Contents

More information

Ui REFRIGERATOR SPEC SHEET

Ui REFRIGERATOR SPEC SHEET Ui REFRIGERATOR SPEC SHEET ISOMETRIC VIEW 19 7/8 20 1/2 32 3/4 FRONT VIEW NOTES: 1. CUTOUT DIMENSIONS: 20 1/2"W X 33"L X 20 3/4"D 2. CUTOUT DIMENSIONS ARE FOR REFRIGERATOR ONLY. REFER TO STAINLESS STEEL

More information

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015 OPERATING MANUAL EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC DOCUMENT NUMBER IN35-03 Revised 15 May 2015 TORREY PINES SCIENTIFIC, INC. 2713 Loker Ave. West Carlsbad,

More information

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Process & TeMPerATUre UniversAl input DigiTAl MeTers Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min

More information

MS-H-Pro-T Magnetic Hotplate-Stirrer with Timer

MS-H-Pro-T Magnetic Hotplate-Stirrer with Timer MS-H-Pro-T Magnetic Hotplate-Stirrer with Timer User Manual MS-H-Pro T Magnetic Hotplate-Stirrer with Timer Please read the User Manual carefully before use, and follow all operating and safety instructions!

More information

Grafisk Maskinfabrik A/S Bregnerødvej 92, DK-3460 Birkerød, Denmark. Website: Phone:

Grafisk Maskinfabrik A/S Bregnerødvej 92, DK-3460 Birkerød, Denmark. Website:    Phone: IR330 Inspection Rewinder with Label Dispenser & Inkjet IR330 Operation Manual Grafisk Maskinfabrik A/S Bregnerødvej 92, DK-3460 Birkerød, Denmark. Website: www.gm.dk. E-Mail: gm@gm.dk. Phone: +45 4581

More information

ST 53.1 User s manual

ST 53.1 User s manual Tech - 1 - ST 53.1 User s manual Table of contents I. Safety... 3 II. Description... 4 III. Installation... 4 IV. Operating the Controller... 6 IV.a) Principle of Operation... 6 IV.b) Control... 6 V. Controller

More information

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range The BINDER MKFT series environmental simulation chamber for low temperature

More information

Termaks AS Lien 79, N-5057 Bergen, Norway Tel: Fax: Web:

Termaks AS Lien 79, N-5057 Bergen, Norway Tel: Fax: Web: Termaks AS Lien 79, N-5057 Bergen, Norway Tel: +47 55 34 20 70 Fax: +47 55 34 11 78 E-mail: termaks@termaks.com Web: www.termaks.com BODONI Foto: istockphoto.com, Termaks WWW.TERMAKS.COM For more than

More information

MD-MINI Dry Bath. Instruction Manual

MD-MINI Dry Bath. Instruction Manual MD-MINI Dry Bath Instruction Manual Catalog No. MD-MINI www.majorsci.com service@majorsci.com Version 01B Revision on: 2013.07.15 Packing list MD-MINI: 1x MD-MINI Dry Bath 1x MD-MINI Lid 1x Power Cord

More information

AZTECA A LITRE STERILISER

AZTECA A LITRE STERILISER Product Description Azteca A-6615 is a fully automatic high-speed pre & post vacuum steam sterilizer. This model is an electrically heated sterilizer, which operates with saturated steam as a sterilizing

More information

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES Generalities HPLC - PELTIER COLUMN-THERMOSTATS GENERALITIES This manual has been updated to the actual standard. It now covers all the features of the actual Jetstream series models. All rights concerning

More information

Built-in Conventional Oven

Built-in Conventional Oven Built-in Conventional Oven LAM3204 User & Installation Guide using this manual Thank you for choosing LAMONA Built - In Oven. This user Manual contains important information on safety and instructions

More information

Dohse Aquaristik GmbH & Co. KG. T-Control Pro. Item no Status: 03/2013. Dohse Aquaristik GmbH & Co. KG

Dohse Aquaristik GmbH & Co. KG. T-Control Pro. Item no Status: 03/2013. Dohse Aquaristik GmbH & Co. KG Dohse Aquaristik GmbH & Co. KG www.dupla.com Using instructiontion T-Control Pro Item no. 80696 Status: 03/2013 Dohse Aquaristik GmbH & Co. KG www.dohse-aquaristik.com Table of contents 1. Introduction.............................................

More information

Intelligent Lead Free Soldering Station OPERATION and MAINTENANCE MANUAL

Intelligent Lead Free Soldering Station OPERATION and MAINTENANCE MANUAL Intelligent Lead Free Soldering Station Sensor in front High frequency heating Digital Calibration Rapid recovery of temperature OPERATION and MAINTENANCE MANUAL Thank you for purchasing a lead free soldering

More information

Forced Convection Constant Temperature Oven. Instruction Manual

Forced Convection Constant Temperature Oven. Instruction Manual Forced Convection Constant Temperature Oven Model DNE 400/40/600 60/80/90 Instruction Manual - Version 7 - Thank you for purchasing "Forced Convection Constant Temperature Oven, DNE Series" of Yamato Scientific

More information

Beacon 800 Gas Monitor Operator s Manual

Beacon 800 Gas Monitor Operator s Manual Beacon 800 Gas Monitor Operator s Manual Part Number: 71-0037RK Revision: F Released: 4/18/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by us to be

More information

CRISTAL Built-in Dish Sterilizer Instruction Manual

CRISTAL Built-in Dish Sterilizer Instruction Manual CRISTAL Built-in Dish Sterilizer Instruction Manual Model No.: D36DSS Version Number: 01 Revision Date: September 2014 Dear user: Thank you for your purchase of CRISTAL built-in dish sterilizer! Please

More information

Whynter Portable Ice Maker 33 lb capacity - White

Whynter Portable Ice Maker 33 lb capacity - White Whynter Portable Ice Maker 33 lb capacity - White Model # : IMC-330WS INSTRUCTION MANUAL Congratulations on your new Whynter product. To ensure proper operation, please read this Instruction Manual carefully

More information

Operating instructions Page 14

Operating instructions Page 14 Operating instructions Page 14 Refrigerator with explosion-proof interior container Read the operating instructions before switching on for the first time 7085 479-00 LKexv Inhalt Disposal notes... 14

More information

incubator, the best in its class

incubator, the best in its class 188 188 188 EuroClone incubator, the best in its class More than a new tool: an environment with unique and unmatched features for your cell cultures. ED AN UCED I DESIGNED AND PRODUCED IN ITALY 1 The

More information

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time Operating instructions Page 14 Refrigerator Read the operating instructions before switching on for the first time 7084 309-00 LKUv Disposal notes The appliance contains reusable materials and should be

More information

Manual Feed Slot Opening. Wastebin. Credit Card Casters

Manual Feed Slot Opening. Wastebin. Credit Card Casters Model# AF300 Contents Product Diagram & Technical Specifications... 3 Warnings... 4 Installation / Safety Instructions... 5 Assembly... 6 Operation... 6-8 Care & Maintenance... 8 Troubleshooting... 9 Warranty,

More information

One-Touch Dispense. Multi-temp selections. 208 F For tea, coffee, instant noodle. 194 F Keep warm around 194 F. 176 F Keep warm around 176 F.

One-Touch Dispense. Multi-temp selections. 208 F For tea, coffee, instant noodle. 194 F Keep warm around 194 F. 176 F Keep warm around 176 F. Instruction Manual Automatic Dispensing Hot Water Pot with Multi-temperature Function Automatic Dispensing One-Touch Dispense FEATURES Reboil Function 5 Temperature Settings Image Of SP-5016 208 F For

More information

Thermo Scientific Wellwash Versa User Manual. Rev. 1.0

Thermo Scientific Wellwash Versa User Manual. Rev. 1.0 Thermo Scientific Wellwash Versa User Manual Rev. 1.0 Thermo Scientific Wellwash Versa User Manual Rev. 1.0, Cat. no. N11166 Copyright Copyright 2010 Thermo Fisher Scientific Corporation. All rights reserved.

More information

Static Pressure Control

Static Pressure Control The (model SPC-2) is a fully programmable controller that provides extensive flexibility for your curtain or awning control needs. The SPC-2 automatically controls the pressure in a room by operating a

More information

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert) Spa Touch Control Panel with 2000, 2100 controllers (Spa Owner s Manual insert) P.N. 7876B February 11, 2015 For Spas equipped with BP2000, BP2100 controllers and Spa Touch panel. Spa Touch Control Panel

More information

IMAGE PRESS & IMAGE PORCELAIN OVEN. 120V, 50/60 Hz Models and 230V, 50/60 Hz Models. Operator s Manual

IMAGE PRESS & IMAGE PORCELAIN OVEN. 120V, 50/60 Hz Models and 230V, 50/60 Hz Models. Operator s Manual IMAGE PRESS & IMAGE PORCELAIN OVEN 120V, 50/60 Hz Models and 230V, 50/60 Hz Models Operator s Manual TABLE OF CONTENTS Congratulations.. 3 Warranty. 3 Safety Notice. 4 Electrical Safety Notes.. 5 Knowledge

More information

User Manual. Rooster series. This Manual applies to: Drying ovens and sterilizers. Rooster Series. Models : Rooster 30, 55, 80, 110, 140, 210 and 230.

User Manual. Rooster series. This Manual applies to: Drying ovens and sterilizers. Rooster Series. Models : Rooster 30, 55, 80, 110, 140, 210 and 230. User Manual series Drying ovens and sterilizers This Manual applies to: Series Models : 3, 55, 8, 11, 14, 21 and 23. Order numbers : ZRD-A53/A555/A78/A511/A714/A521/A723. Shanghai ZHICHENG Manufacturing

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or

More information

Undercounter Refrigerator Operation Manual

Undercounter Refrigerator Operation Manual Undercounter Refrigerator Operation Manual i.series and Horizon Series Model Group i.series Horizon Series Blood Bank ib105 (Version A) HB105 (Version A) Laboratory/Pharmacy ilr105 (Version A) HLR105 (Version

More information

IMR IX176 Portable Gas Detector User Manual

IMR IX176 Portable Gas Detector User Manual IMR Portable Gas Detector User Manual Read this manual carefully before using this device. (727) 328-2818 / (800) RING-IMR Fax: (727) 328-2826 www.imrusa.com Ver. 1.0A4 CONTENTS SERVICE GUIDELINES... 3

More information

Dryer Controller M720

Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 2.00 Software version 2.00 Manual M720 Dryer controller Page 1 of 60 Document history Preliminary version: - Created in April, 2009 Hardware Version 2.00,

More information

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460) Operating Manual TS400 Test Station for Microtector II Series (G450/G460) GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, Germany TEL. +49 / (0)2 31 / 5 64 00 0 FAX +49 / (0)2 31 /

More information

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR)

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR) Instruction Manual For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR) Corning Cat. No. 230V 230V Model No. Product Top Plate Size

More information

Operator s Manual. The Quietek

Operator s Manual. The Quietek Operator s Manual The Quietek Congratulations! Congratulations on your purchase of the Quietek euthanization system. Please read this operator s manual which explains proper operation of the instrument.

More information

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA G-Series Cooler UPRIGHT COOLER Part No.11IPA-062800 Instruction Manual FOR YOUR FUTURE REFERENCE Thank you for using our product. This manual will guide you in getting the best use of your cooler. Remember

More information

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents - English... 1 Instruction Manual Analog, Dry Block Heater, 1 Block, HB1AL Analog, Dry Block Heater, 2 Block, HB2AL Analog, Dry Block Heater, 4 Block, HB4AL Analog, Dry Block Heater, 6 Block, HB6AL Digital,

More information

Aluminum Heating Mantles

Aluminum Heating Mantles Aluminum Heating Mantles ON/OFF HOT User Guide Version 1.3 ON/OFF IEC power inlet socket Power supply switch (large-volume models). Power to either the lower part of the element or the upper and lower

More information

Focus 4010\ Focus 4010 HT porcelain firing furnace

Focus 4010\ Focus 4010 HT porcelain firing furnace INSTRUCTION MANUAL Focus 4010\ Focus 4010 HT porcelain firing furnace Warning You have available one of the most precise dental furnaces equipped with a heating muffle made by the original manufacturer

More information

THX-DL Data Logger USER & INSTALLATION MANUAL V

THX-DL Data Logger USER & INSTALLATION MANUAL V THX-DL Data Logger USER & INSTALLATION MANUAL V1.2012 www.thermomax-refrigeration.com Contents PRESENTATION Summary of Features 2 INSTALLATION Safety Precautions 4 THX Unit 4 Sensors 4 Alarm Relay 4 Power

More information

VF X Series. User Manual. SKOPE Vertical Freezer. MAN11137 Rev. 1.1 Sep VF650X

VF X Series. User Manual. SKOPE Vertical Freezer. MAN11137 Rev. 1.1 Sep VF650X VF X Series SKOPE Vertical Freezer MAN11137 Rev. 1.1 Sep. 2016 VF650X SKOPE Warranty Protection Register now for peace of mind It s quick and simple. Take a few minutes to register your SKOPE product and

More information

Multi-Lab REFRIGERATORS Frigidere medicale

Multi-Lab REFRIGERATORS Frigidere medicale REFRIGERATORS REFRIGERATORS 2 finishings available, epoxy coated steel white colour or stainless steel (according to the model) high insulation thickness from 40 to 75 mm (according to the model) (1) rounded

More information

Thermo Scientific Wellwash User Manual. Rev. 1.0

Thermo Scientific Wellwash User Manual. Rev. 1.0 Thermo Scientific Wellwash User Manual Rev. 1.0 Thermo Scientific Wellwash User Manual Rev. 1.0, Cat. no. N11163 Copyright Copyright 2010 Thermo Fisher Scientific Corporation. All rights reserved. Printed

More information

Laptop / PC Programming Manual

Laptop / PC Programming Manual Laptop / PC Programming Manual Doc. # Fire PC Program rev B 01.07 This Document is property of Evax Systems, Inc. The Evax Fire Solutions Programmer Components 2 1.0 System Setup 4 1.1 Interface Setup

More information

BUILT-IN OVEN MODEL: EBO-D7080D(SS) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference.

BUILT-IN OVEN MODEL: EBO-D7080D(SS) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference. BUILT-IN OVEN MODEL: EBO-D7080D(SS) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference. Record model number and serial number of the set. See the

More information

EXC-450 User s Manual

EXC-450 User s Manual Superior Liquid Cooling Systems www.koolance.com EXC-450 User s Manual English v1.0 ISO 9001 Printed in Korea A newer version of this User Manual may exist. Please be sure to check our support page for

More information

FW422. Integrated In Column Larder Fridge. Installation, use and maintenance.

FW422. Integrated In Column Larder Fridge. Installation, use and maintenance. FW422 Integrated In Column Larder Fridge Installation, use and maintenance www.cda.eu Contents: 3 Important information 5 Important safety warnings 6 Before first use 7 Setting the temperature 7 Guidance

More information

Drying and heating chambers

Drying and heating chambers Drying and heating chambers Avantgarde.Line ED FD FED series Classic.Line E ED FD FED FP M series Solid.Line ED-S FD-S series EN PRODUCT SELECTION DRYING AND HEATING CHAMBERS Classic.Line Avantgarde.Line

More information

LUMA-NET 804CP / 808CP REMOTE CONTROL PANEL

LUMA-NET 804CP / 808CP REMOTE CONTROL PANEL LUMA-NET 804CP / 808CP REMOTE CONTROL PANEL INSTALLATION AND OPERATION GUIDE INTRODUCTION The NSI 804CP and 808CP represents a key part of a state of the art, total lighting control system. Combined with

More information

USER MANUAL myvacbot SN500 Robot Vacuum

USER MANUAL myvacbot SN500 Robot Vacuum USER MANUAL myvacbot SN500 Robot Vacuum CONTTS 01 SAFETY INSTRUCTIONS... 6 02 PARTS... 9 03 PRODUCT OVERVIEW... 10 04 CHARGING STATION... 11 05 PRODUCT INSTALLATION... 12 06 PRODUCT CLEANING MODE... 12

More information

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS MD5-601 AND MD5-603

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS MD5-601 AND MD5-603 OPERATING MANUAL MOLECULAR DIMENSIONS, INC. PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS MD5-601 AND MD5-603 DOCUMENT NUMBER DM5-601/603-1 January 21, 2011 MOLECULAR DIMENSIONS, INC. United Kingdom Office

More information

26 LB CAPACITY ICE MAKER

26 LB CAPACITY ICE MAKER 26 LB CAPACITY ICE MAKER INSTRUCTION MANUAL CATALOG NUMBER BIMY126S Thank you for choosing BLACK+DECKER! PLEASE READ BEFORE RETURNING THIS PRODUCT FOR ANY REASON. If you have a question or experience a

More information

Installation and user manual

Installation and user manual Installation and user manual Please read carefully and retain for future reference Models EcoHeat: C3, C5, C6, C8, C9, C11, C12 Rev.1_09-07-15 Page 1 Table of Contents 1 IMPORTANT: WARNINGS 1.1 GENERAL

More information