NOT FOR CONSTRUCTION PD-101 NMSU ALAMOGORDO 2400 SCENIC DRIVE ALAMOGORDO, NM PLUMBING DEMOLITION PLAN. regenerating architecture

Size: px
Start display at page:

Download "NOT FOR CONSTRUCTION PD-101 NMSU ALAMOGORDO 2400 SCENIC DRIVE ALAMOGORDO, NM PLUMBING DEMOLITION PLAN. regenerating architecture"

Transcription

1 3 COMP SINK WH FREEZER ICE REF FD GREASE TRAP TABLE PIZZA OVEN OVEN over PAN RACK MW CONDIMENTS NOT FOR CONSTRUCTION CABINETRY ELEC PANEL ELEC PANEL DISPLAY WATER SOFTENER TABLE MOP SINK PLUMBING DEMOLITION PLAN PD101 DISPLAY DISPLAY FD coffee

2 SANITARY SEWER PLAN P101 EXISTING SIDEWALK ABOVE GRADE VESTIBULE 110 MECH M108 STORAGE 108A KITCHEN SERVERY SEATING 107 RESTROOM R108 OFFICE 108B

3 WATER AND GAS PIPING PLAN P201 VESTIBULE 110 SERVERY 107 MECH M108 STORAGE 108A KITCHEN 108 SEATING 107 RESTROOM R108 OFFICE 108B

4 PLUMBING ROOF PLAN P301

5 PLUMBING SCHEDULE, DETAILS AND LEGEND P401

6 PLAN M101 HALL 109 VESTIBULE 110 SERVERY 107 MECH M108 STORAGE 108A SEATING 107 KITCHEN 108 OFFICE 108B RESTROOM R108

7 ROOF PLAN M201

8 SCHEDULE, DETAILS AND LEGEND M301

9 INFORMATION NO. MODEL DIMENSIONS (IN.) LENGTH WIDTH HEIGHT CONSTR. 430 SS TEMP RATING EXHAUST COLLAR(S) WIDTH LENGTH DIA. CFM S.P SUPPLY PLENUM INFORMATION SIZE (IN.) LED LIGHT(S) TOTAL COLLARS POS. TYPE INSULATED DAMPER(S) NO. L W H SUPPLIED QTY CFM TYPE MOUNTING QTY W L DIA. CFM S.P. VEL. 1 9 FT FRONT ASP NO NO NO 1620 MUA FACTORY TOTAL CFM MUA CFM SUPPLY AC CFM TOTAL SECTION WEIGHT LOCATION LBS FT XBEW108S WHERE SINGLE DEG F EXPOSED INFORMATION LIGHTING DETAILS GREASE FILTRATION DETAILS UTILITY CABINET(S) FIXTURE TYPE FOOT TYPE / MODEL SIZE (IN.) QTY QTY L H LOCATION FIRE SYSTEM CONTROLS NO. BULB / LAMP INFO CANDLES MATERIAL TYPE SIZE MODEL INTERFACE FT INCANDESCENT (GLOBE) BAFFLE W A19 (BULBS NOT INCL.) STAINLESS STEEL 3 20 RIGHT AMEREX KP 3.75 OPTIONS UL 710 LISTED W/ OUT EXHAUST FIRE DAMPER UL #R25625 BACK INTEGRAL AIR SPACE 3 IN WIDE 18 IN HIGH CEILING ENCLOSURES FRONT LEFT RIGHT FIELD INSTALLED FACTORY MOUNTED EXHAUST COLLAR(S) BACKSPLASH IN HIGH IN LONG PERFORMANCE ENHANCING LIP (PEL) TECHNOLOGY STANDING SEAM CONSTRUCTION FOR SUPERIOR STRENGTH FP 1 FP Range 2 burners Fuel Type: Gas 12" L X 30" W X 36" H 36 IN. OC 7.0 Griddle Fuel Type: Gas 48" L X 30" W X 36" H FP 19.0 : 9 ft Hood SECTION 1 ELEVATION VIEW FP 10.0 REAR INTEGRAL AIR SPACE TEMPERATURE SENSORS FIELD WIRING TO CONTROLS REQUIRED : 9 ft Hood SECTION 1 PLAN VIEW FP Fryer Full Vat with Dripboard Fuel Type: Gas 16" L X 30" W X 36" H FP Fryer Full Vat with Dripboard Fuel Type: Gas 16" L X 30" W X 36" H FP RELEASE MODULE AGENT TANK in. LENGTH 6.0 BACKSPLASH PANEL AMEREX FIRE SYSTEM : Amerex Fire system 120 in ABOVE FINISHED FLOOR : 9 ft Hood SECTION VIEW 10.0 PERFORATED AIR CURTAIN UL LISTED LIGHT FIXTURE CHROME APPLIANCE DROPS TEMPERATURE SENSORS UL LISTED STANDARD BAFFLE FILTERS 4.0 REMOVABLE GREASE CUP W/ CONCEALED GREASE TROUGH INTEGRAL AIRSPACE FLAT BACKSPLASH PANEL INST. DETAIL SLIDE PANEL BEHIND SECURE PANELS TO WALL STUDS (HOLES AND FASTNERS BY OTHERS) FLAT BACKSPLASH PANEL ENCLOSURE PANEL INSTALLATION DETAIL 5/16'' BOLTS PROVIDED BY MANUFACTURER FASTEN TO WALL HARDWARE BY OTHERS TOP CLAMPS PROVIDED BY MANUFACTURER HANGING HEIGHT FOR FIRE SYSTEMS VERIFICATION OF HANGING HEIGHT ABOVE FINISHED FLOOR (A.F.F.) IS REQUIRED FOR CORRECT PLACEMENT OF FIRE SYSTEM NOZZLES. RECOMMENDED HANGING HEIGHT = 80" FROM FINISHED FLOOR TO LOWER FRONT EDGE OF. OTHER HANGING HEIGHT = " FROM FINISHED FLOOR TO LOWER EDGE OF. SUPPLY PLENUM HANGER BRACKET DETAIL TYPICAL HANGER BRACKET SUPPLY PLENUM LENGTH HANGER BRACKET DETAIL TYPICAL HANGER BRACKET NOT TO SCALE ON S OVER 120" REFERENCE SCALED DRAWING FOR ACTUAL LOCATIONS 3.6 LENGTH THREADED ROD (1/2") WASHER HANGER BRACKET 1/2" NUT TYPICAL HANGING METHOD PROJECT 8/2/2016 DICK SYMONS NEW MEXICO DICK SYMONS SIMPLE1@MSN.COM NOT FOR CONSTRUCTION (505) FT M EC H ANICA L P L U M B IN G DETAILS M302

10 EQUIPMENT SCHEDULE Tempered MakeUp Air Unit Qty Accurex Model Volume External SP Total SP FRPM Operating Power NOTE: Roof Opening Requirements: Mark: Tempered Supply Fan Minimum Roof Opening: The minimum roof opening size is the illustrated duct diameter plus 0.25 in. on all sides. For example: If the duct size is 14 x 14 in. square, the minimum roof opening size is 14.5 x 14.5 in. square. Maximum Roof Opening: There must be a minimum perimeter of 1.75 in. between the roof opening and the roof curb. For example: If the roof curb is 75 x 30 in. square, the maximum roof opening is 71.5 x 26.5 in. inches square. NOTE: The weatherhood and filter sections of the makeup air unit are not supported by the curb. This is by design, in order to help alleviate water infiltration issues. MUA Unit supports are shipped loose with unit. Weight 1 XDG109H10 1,620 CFM 0.4 in. wg in. wg hp 608 lb Size 1 1/2 hp Type Motor Information V/C/P Enclosure Motor RPM Windings 208/60/3 ODP Gas Type Temperature Heating Winter DB Max Δ Max LAT Input Energy Output Direct Gas Natural 17.7 F 52.0 F 70.0 F 81.8 MBH 75.2 MBH 92% 3/4" Cooling Type Evaporative Cooling Media CELdek Dry 95.2 F Cooling Summer Bulb 65.3 F Filters 2in. Aluminum Mesh MCA Efficiency Gas Cooling Control Recirculating Pump **Required flow and inlet pressure are for supply line sizing only. They do not represent water usage during normal operation. Consult factory for actual water usage PLAN VIEW Wet Outlet Sound Power By Octave Band LwA A weighted sound power level based on ANSI S1.4 dba A weighted sound pressure level base on 11.f db attenuation per octabe band at 5.0 ft. Noise Criteria (NC) based on an average attenuation of 11.5 db per octabe band at 5.0 ft. ELEVATION VIEW FOOTPRINT ACCESS SIDE EVAP COOLING ACCESS SIDE BURNER ACCESS SIDE CONTROL CENTER LwA 76.3 MOP 20 Building Gas Pressure 1/2 PSI Control Access 11a Required Flow** dba NA Sones 13.3 OPTIONS AND ACCESSORIES Air Flow Arrangement: Outdoor Air Only Damper: Inlet Outdoor Air Intake Position: End Discharge Position: Bottom Coating: Galvanized Insulation: Duct Liner Heat Source On Access Side: RightHand Control Center Direct Gas Options/Accessories Approvals: ETL and IRI Temperature Control: Discharge Flame Sensing: Flame Rod Ignition Control: Direct Spark Unit Rated Gas Pressure: 1/2 PSI Evap Cooling Options/Accessories Evap Media: CELdek Evap Control: Recirculating Pump With Louvered Intake and Aluminum Mesh Filters, 16x25x2 (1), 12x25x2 (1) Evap Equip. Support: Qty(1) H(12.25 in.) x L(22 in.), GESS Mounting: GPI24.5/74.5G12 Curb Includes: 1 in. Insul CURB LENGTH ACTUAL Supply Duct END VIEW CURB WIDTH ACTUAL MAIN POWER TO UNIT 208V GROUND BLUE R S2 S4 S1 P1 EVAP PUMP FSC RH RED RED L1 L2 L3 OFF G H W1 Y1 DS1 T1 101 RED T2 T3 LT. BLUE HLC1 R R 24 WHITE PINK RED YELLOW ST1 C RF PS ST2 NO 14 SENSOR SPARK BLACK TR3 RED BLACK ST1 O.L ST2 O.L WHITE TS2 1 2 FU7 115V 3A,600V CLASS RC CC BLACK BLACK VA RF RED LT. BLUE NC SENSE PS2 SPARK BLUE TR1 24V C 5 6 MOD 75 VA PINK TH/24V BLUE BROWN YELLOW 27 FSG INT 10 SEC AMP 7 DISCHARGE STAT. TEMP RANGE 5590 F RED 40VA 8 O VALVE TR5 24V FU RED 2CBLID GND (BURNER) BL D1 PINK RF A2 A1 ST1 A2 A1 ST2 A2 A1 BLACK 2CBLID RC A2 A1 GND (24V) ORANGE BLUE YELLOW RH A2 A1 V2 TR6 30 VA 24 VAC WHITE ORANGE ST1 O.L. L1 L2 L3 ST2 O.L. L1 L2 L3 C WHITE T1 T2 T3 T1 T2 T3 INLET DAMPER SUPPLY FAN RELAY SUPPLY FAN EXHAUST FAN (1) POST HEAT COOLING M1 SUPPLY FAN MOTOR M2 EXHAUST FAN MOTOR (1) 21 DIRECT GAS CONTROL Wiring Diagram Code: AD11N412A011A00NM15 CAUTION UNIT SHALL BE GROUNDED IN ACCORDANCE WITH N.E.C. POWER MUST BE OFF WHILE SERVICING. NOTES USE COPPER CONDUCTORS ONLY 60 C FOR TERMINALS RATED LESS THAN 100 AMPS. 75 C FOR TERMINALS RATED 100 AMPS OR MORE. FIELD CONTROL WIRING RESISTANCE SHOULD NOT EXCEED 0.75 OHM. FIELD WIRED FACTORY SUPPLIED AND WIRED WIRE COLOR CODE BK BLACK BL BLUE BR BROWN GY GRAY LT BL LIGHT BLUE O ORANGE PK PINK PR PURPLE R RED W WHITE Y YELLOW Wiring Template: M14 ENGINEERED RESTAURANT SYSTEMS LEGEND AMP AMPLIFIER D1 INLET DAMPER DS1 MAIN DISCONNECT SWITCH FSC FIRE SYSTEM CONTACT FSG FLAME SAFE GUARD FU# FUSE HLC HIGH LIMIT CONTROL M# MOTOR MOD MODULATING VALVE OL# MOTOR OVERLOAD P# EVAP PUMP PS2 AIR PROVING SWITCH RC COOL RELAY RF SUPPLY FAN RELAY RH HEAT RELAY S1 EXHAUST FAN SWITCH S2 FAN SWITCH S4 HEAT AND COOL SWITCH ST# MOTOR STARTER TR# TRANSFORMER TS2 DISCHARGE AIR SENSOR V2 MAIN VALVE PROJECT 8/2/2016 DICK SYMONS NEW MEXICO DICK SYMONS SIMPLE1@MSN.COM NOT FOR CONSTRUCTION (505) TEMPERED SUPPLY FAN M EC H ANICA L P L U M B IN G DETAILS M303

11 DICK SYMONS NEW MEXICO DICK SYMONS NOT FOR CONSTRUCTION (505) EXHAUST FAN PROJECT 8/2/2016 Belt Drive Upblast Centrifugal Roof Exhaust Fan INFORMATION FAN INFORMATION MOTOR INFORMATION QTY MODEL VOLUME (CFM) EXTERNAL SP (IN WG) TOTAL SP (IN WG) FAN RPM OPERATING POWER (HP) WEIGHT (LB.) SIZE (HP) V/C/P ENCLOSURE MOTOR RPM WINDINGS NEC FLA* 1 Exhaust Fan XRUB , , /60/3 OP *NEC FLA Based on tables 150 or 148 of National Electrical Code Actual motor FLA may vary, for sizing thermal overload, consult factory. SELECTED OPTIONS AND ACCESSORIES Standard curb cap size 22 in. square UL/cUL 762 Listed "Power Ventilators for Rest. Exh. Appliances" Switch, NEMA1, Toggle, Shipped with Unit Roof CurbGalv., GPFV22G24, Under Sized 1 in. Total Hinged Base (Attached) Curb Seal (Attached) Grease Trap (PN ) Heat Baffle (Attached) Cleanout Port Max.Exhaust Duct Size See Table 18.5 SQ Suggested Roof Opening Standard Duct 16 SQ TOP VIEW 28.9 Dia Hinged Base Flat Roof Curb NOTE: Overall height may be greater depending on motor FRONT VIEW DETAILS M304

12 FIRE SYSTEM INFORMATION AMEREX FIRE SYSTEM 108 IN MODEL AMEREX KP WET CHEMICAL LOCATION CABINET RIGHT END OF 9 FT FLOW POINTS S PCU 10 UTILIZED 11 AVAILABLE SUPPLY LINE DETECTION CONTINUOUS FUSIBLE LINK (S) PROTECTED BY FIRE SYSTEM 9 FT SECTION 1 CONTROL INFORMATION SWITCHES AND CONTROLS ELECTRICAL CONTROL PACKAGE MODEL LOCATION TEMP INTERLOCK SHIP LOOSE TYPE SWITCHES USER INTERFACE LOCATION SHIP LOOSE FIRE SYSTEM OPTIONS AND ACCESSORIES FULL INSTALLATION (INCLUDES PREPIPED (S) WITH DETECTION AND FACTORY COORDINATED INSTALL) CHROME SLEEVES FOR FACTORY PROVIDED APPLIANCES DROPS INCLUDED GAS VALVE INCLUDED SHUTOFF VALVE, 2.00" (AMEREX) PART# SUPPRESSION AGENT INCLUDED 3.75 GAL. [(1) 3.75 TANK(S)] REMOTE PULL STATION STANDARD INSTALLATION AT SINGLE POINT OF EGRESS 2 AMEREX KP (WET CHEMICAL) FIRE PROTECTION SYSTEM MODEL FSSK 1 CONTROL PANEL 1. MRM ( RELEASE MODULE) 2. NITROGEN ACTUATION CYLINDER 3. MICROSWITCH 3 NOT TO SCALE NOTES: WET CHEMICAL FIRE PROTECTION SYSTEM TO BE AMEREX KP, DESIGNED IN COMPLIANCE WITH UL 300 REQUIREMENTS. VERIFICATION OF ALL COOKING EQUIPMENT MAKE, MODEL AND LOCATION REQUIRED FOR ALL FIRE PROTECTION SYSTEMS. ALL FIRE SYSTEM PIPING IS STANDARDLY TO THE RIGHT END OF THE UNLESS A WALL IS LOCATED ON THE RIGHT END. AMEREX MRM/PRM TO BE LOCATED WITHIN 60" OF. THE BASIC FIRE SYSTEM WILL INCLUDE THE FOLLOWING: GAS SHUTOFF VALVE, IF REQUIRED, TO BE SUPPLIED BY MANUFACTURER (UP TO 2" DIAMETER AS STANDARD), AND INSTALLED BY A LICENSED PLUMBER. MICRO SWITCH TO BE SUPPLIED BY MANUFACTURER FOR CONNECTION TO, BUT NOT LIMITED TO, BUILDING ALARM SYSTEM(S), EXHAUST AND SUPPLY FANS AND ELECTRICAL POWER SHUT DOWN. FIELD WIRING AND CONNECTIONS TO BE PERFORMED BY A LICENSED ELECTRICIAN. THREE TRIPS TO THE JOBSITE ANY STATE OR LOCAL INSTALLATION PERMITS. THE BASIC FIRE SYSTEM DOES NOT INCLUDE THE FOLLOWING: FULL DUMP TEST OTHER THAN WHT IS SPECIFIED PER THE INSTALLATION MANUAL,OR TO SATISFY A STATE OR LOCAL CODE. MORE THEN THREE TRIPS TO THE JOBSITE OR SPECIAL TRANSPORTATION, OR OVERNIGHT LODGING REQUIREMENTS IN REMOTE AREAS. NORMAL TRAVEL DISTANCE IS FIRST 50 MI. (80.5 KM) FROM OFFICE. SPECIAL CLASSES OR ADDITIONAL LABOR FOR ACCESS TO SECURITY SENSITIVE AREAS. INSTALLATION OF GAS SHUTOFF VALVE. SPECIAL DRAWINGS REQUIRED TO SATISFY STATE OR LOCAL CODE. UNION LABOR, GOVERNMENT LABOR, OR PREVAILING WAGES REQUIRED FOR FINAL FIELD HOOKUP. ANY AND ALL ELECTRICAL COMPONENTS/CONNECTIONS REQUIRED TO SHUT DOWN FANS, SHUT OFF DEVICE FOR ELECTRIC COOKING EQUIPMENT (SHUNT TRIP BREAKER), OR ACTIVATE AN ALARM SYSTEM, ETC. ANY DISMANTLING OR REASSEMBLY REQUIRED TO GAIN ACCESS TO THE FIRE SUPPRESSION PIPING LOCATED ON THE TOP OF THE. PLAN EXAMINATION FEES, PE OR FPS APPROVAL STAMP. ROUGHIN CONDUIT FOR REMOTE PULL STATION OR GAS VALVE (FOR FLUSH MOUNTED PULL STATION). INSTALLATION OF MORE THAN (1) REMOTE PULL STATIONS OR DISTANCES GREATER THAN 20 FT (6.1M.) PARTS OR LABOR REQUIRED TO CORRECT PIPING DUE TO COOKING EQUIPMENT CHANGES OR DEVIATION FROM PLANS. OR ANY CHARGES FOR MISSING OR ADDITIONAL PARTS OTHER THEN THOSE INDICATED ON THE FIRE SUPPRESSION DETAIL WIRING DIAGRAMS W/ DPDT MICRO SWITCH DPDT SWITCHES PROVIDED BY MANUFACTURER MAY BE WIRED PER TYPICAL EXAMPLES SHOWN, VERIFY WITH LOCAL CODES AND EQUIPMENT SUPPLIED AS THE CONNECTION NEEDED FOR YOUR INSTALLATION. CONNECTION TO BUILDINGS ALARM NO NC NO NC } INPUT NO NC VOLTAGE FREE CONTACTS FOR BUILDING ALARM(S) CONNECTION TO COOKING EQUIPMENT SHUT DOWN ~ 120 VAC DO NOT SHUT DOWN EXHAUST FANS WITH THIS METHOD OF WIRING, IF PROHIBITED BY LOCAL CODES. N } INPUT POWER TO COOKING EQUIPMENT SHUNT TRIP BREAKER 120 VAC N } INPUT ELECTRIC GAS VALVE IF RESET RELAY IS USED SEE OPTION A OR B AT RIGHT, GAS SHUT OFF VALVE DOES NOT REQUIRE ELECTRICAL CONNECTION. CONNECTION TO FAN SHUT DOWN POWER TO FAN(S) MANUAL SWITCH FAN STARTER NOTES: 1. DENOTES FIELD INSTALLATION. 2. DENOTES FACTORY INSTALLATION. 3. GAS VALVES: "UL LISTED ELECTRICALLYOPERATED SAFETY VALVE FOR NATURAL, OR LP GAS AS NEEDED OF APPROPRIATE PRESSURE AND TEMPERATURE RATING, 110V/60 HZ" OR AMEREX GAS VALVES, PART NUMBERS 12790, 12791, 12792, 12793, 12794, 12870, 12871, 12872, 12873, 12874, AND CONTROL FEATURES CONTROL PANEL ENCLOSURE GRAY ENCLOSURE (NEMA3R) DIMENSIONS 8 X 8 X 4 2 POSITION LIGHT SWITCH QTY 1 3 POSITION TEMPERING SWITCH QTY 1 2 POSITION FAN SWITCH QTY 1 INTEGRATED EXHAUST TEMPERATURE INTERLOCK SYSTEM FACTORY MOUNTED EXHAUST TEMPERATURE SENSORS QTY 1 COMPLIES WITH INTERNATIONAL CODE 2015 SECTION L1 H1 BK CP1 RD T1A TS1 Temperature Interlock Electrical Prewire Package NMSU Alamogordo CONTROL INPUT: 120VAC, 15AMPS FROM BREAKER T1B TC S1H S1 FS S1 FIELD WIRE FIRE SYSTEM MICROSWITCH NO NC CP2 TEMPERATURE INTERLOCK CALIBRATION C CONTROL INPUT: 24/120 VAC, 15AMPS FROM BREAKER 1. PRESS THE SET BUTTON TO SEE THE FIRST SET POINT. (PRESS THE SET BUTTON TWICE, SLOWLY TO SEE THE SECOND SET POINT) 2. PRESS THE UP/DOWN ARROW BUTTON TO CHANGE THE SET POINT. 3. PRESS THE SET BUTTON TO VIEW THE CURRENT TEMPERATURE. 4. CHECK SYSTEM OPERATION BEFORE MAKING ADDITIONAL ADJUSTMENTS RD ST TYP. EXHAUST ST TYP. EXHAUST ST TYP. SUPPLY WT SYSTEM DRAWING NOTE These drawings shall not be removed from this equipment. For additional information call ACCUREX at N N1 FIELD MOUNTED SWITCH FIELD WIRING TO SWITCH REQUIRED G L1 R LIGHT INPUT: 120VAC, 15AMPS FROM BREAKER S21 LT 1400W max. CONTROL PANEL Installation Location: Ship Loose Switches Ship Loose for Remote Mounting BK 8.0 This Control Panel only provides control power to signal operation of supply and exhaust starters Starters are Not provided by manufacturer, to be provided by, wired and mounted by others LT CONNECTIONS TO TEMPERED MUA FAN S HEAT OFF COOL WH N W1Y1 Panel Mark: Switches and Controls Hood Mark(s): Motor Fan Mark Volt 1 Qty. Fan Switches (03) X Exhaust in Fire 1 Qty. Light Switches (03) MUA Interface 1 Qty. Temp. Switches (01) Lights Out in Fire One Switch for L & F Fire Relay (#1) X Digitial Temperature Interlock Extra Fire Relay (#2) 1 Mounted Sensors Factory Extra Fire Relay (#3) 0 Mounted Sensors Field DPDT Relay w/sf X Heat Switch DPDT Relay w/ef Tempering SW X Cool Switch Off Delay Relay AD Switch SF Failure Light X Remote Switches EF Failure Light Audible Alarm Fan Failure Light (Appl.) Gas Reset Gas Off w/fans Aux. Supply Contact Power for Gas Solenoid Tie in WWCP Power for Shunt Trip TORQUE: TERMINAL BLOCKS = 8 LB.IN GROUNDING BLOCKS = 8 LB.IN UL LISTED Wiring Diagram Code: HP PH FLA Wire USE MINIMUM 60 Copper Wire Breaker FIELD WIRING: LABEL DESCRIPTION EF Exhaust Fan FACTORY WIRING SF Supply Fan FIELD WIRING ST Starter OL OverLoad ALL WIRING 90 C 14 GA. UNLESS SPECIFIED C Contactor G Ground S LT Switch Light WIRE COLOR FS Fire Switch R Relay BK black AF Air Flow Switch BL blue SV Gas Solenoid BR brown STB Shunt Trip Breaker OR orange D Damper PR purple PB PushButton RD red EC Evap Cooler YW yellow WH white TS Temperature Sensor TC Temperature Controller UNDER SUBJECT 891 FILE #E PROJECT 6/8/2016 AMEREX FIRE SYSTEM 120 IN AND SWITCHES AND CONTROLS NOT FOR CONSTRUCTION DICK SYMONS NEW MEXICO DICK SYMONS SIMPLE1@MSN.COM (505) M EC H ANICA L P L U M B IN G DETAILS M305

GENERAL CONTRACTOR NOTES GEN WALK-IN NOTES 1. E.C. TO VERIFY EXACT SIZE & LOCATION OF COMPRESSORS FOR WALK-IN BOXES W/ KEC & ARCHITECT.

GENERAL CONTRACTOR NOTES GEN WALK-IN NOTES 1. E.C. TO VERIFY EXACT SIZE & LOCATION OF COMPRESSORS FOR WALK-IN BOXES W/ KEC & ARCHITECT. GENERAL CONTRACTOR NOTES 78 79 00 7 SF 00 80 30 Blake Street, Suite 00, CO 8005 303.86.8555 05 Main Street, Unit C0 Edwards, CO 863 9.96.8960 75 76 WARMING KITCHEN BEVERAGE 8 66 6 SF 5. E.C. TO VERIFY

More information

Type 1, Baffle Filter Single Wall - Exhaust Only Wall Canopy. Height (in.) Exhaust SP (in. w.g.) XBEW

Type 1, Baffle Filter Single Wall - Exhaust Only Wall Canopy. Height (in.) Exhaust SP (in. w.g.) XBEW Mark: Hood-1 XBEW Type 1, Baffle Filter Single Wall - Exhaust Only Wall Canopy Model Hood Length (in.) Width (in.) Bottom Width (in.) Front Height (in.) Back Exhaust Volume (CFM) Exhaust SP (in. w.g.)

More information

Indirect Gas-Fired Make-Up Air

Indirect Gas-Fired Make-Up Air Indirect Gas-Fired Make-Up Air Model IG 800 to 7,000 cfm Up to 400,000 Btu/hr Multiple Furnace Control Options Optional Evaporative Cooling May 20041 Product Features Model IG Indirect Gas-Fired Make-Up

More information

Direct Gas-Fired Make-Up Air

Direct Gas-Fired Make-Up Air Direct Gas-Fired Make-Up Air Model TSU Heavy Duty, High Airflow Applications Manufacturing and Industrial Facilities Up to 64,000 cfm August 2012 Products Model TSU Direct Gas-Fired Make-Up Air Unit The

More information

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation Industrial Space Heating Direct Gas-Fired Heating Greenheat 00% Outdoor Air Greenheat 50/50 Recirculation 80/0 Recirculation March 008 Product Overview Industrial Space Heating Greenheck s space heating

More information

XRRS Specification Fire Ready Hood

XRRS Specification Fire Ready Hood XRRS Specification Fire Ready Hood ************************************************************************************************************************ Note to User: This document is subject to copyright

More information

Modular Supply Make-Up Air Unit

Modular Supply Make-Up Air Unit Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features

More information

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM PART 1 GENERAL 1.01 SUMMARY SECTION 15371 KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM A. Section Includes: A complete wet chemical automatic fire suppression system for the exhaust hood, including necessary

More information

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM PART 1 GENERAL 1.01 SUMMARY SECTION 15371 KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM A. Section Includes: A complete automatic fire suppression system for the exhaust hood, including necessary accessories.

More information

PARTS LIST PL503 WVF-886 VENTLESS FRYER WITH OR WITHOUT ROLL WARMER CONTENTS

PARTS LIST PL503 WVF-886 VENTLESS FRYER WITH OR WITHOUT ROLL WARMER CONTENTS WELLS BLOOMFIELD, LLC 2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439 telephone: 775-689-5703 fax: 775-689-5976 www.wellsbloomfield.com 503 PARTS LIST PL503 WVF-886 VENTLESS FRYER WITH OR WITHOUT ROLL WARMER

More information

Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260)

Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260) Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN 46706 (260) 925-6550 Fax: (260) 925-6093 Industrial Facility Midwest Re: Facility Ventilation Audit Schust Engineering, Inc. is pleased

More information

KIC Air Curtains. Technical Guide

KIC Air Curtains. Technical Guide TGKIC-3 KIC Air Curtains Technical Guide AIR PERFORMANCE AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. King certifies that the air curtains shown herein are licensed to bear the AMCA seal. The

More information

900 N. Via Piemonte Ontario, CA

900 N. Via Piemonte Ontario, CA 2 3 L 8 5'-0" 6'-1" 5'-0" 4'-0" 2'-0" D.5 6" 9'-9" K 2 1 2 " 5'-0" 2'-0" 1'-2" 8" 4 4.3 7'-0" C.6 1'-8 1 2 " 7'-0" 8" 10'-6" 5'-0" 8" 6" 6'-6" 6'-3" PLUMBING SCOPE OF WORK - DRAINS 7'-3" 6'-8" KEC TO PROVIDE:

More information

Modular Heating & Ventilating Unit Model IGX-HV

Modular Heating & Ventilating Unit Model IGX-HV Modular Heating & Ventilating Unit Model IGX-HV Indirect Gas-Fired Heating Evaporative Chilled Water DX Cooling October 2008 Product Features Model IGX-HV Indirect Gas-Fired Heating and Ventilating Unit

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 479928 Grease Trapper Kitchen Exhaust Pollution Control Unit Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before

More information

Field Start-Up Sheet Direct Fired Gas Equipment

Field Start-Up Sheet Direct Fired Gas Equipment Customer: Sales Representative: Model Number: Serial Number: Field Start-Up Sheet Direct Fired Gas Equipment ***Please Print*** INITIAL INSPECTION I. Installer Responsibilities 1. Remote Panel: All interconnecting

More information

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units TECHNICAL SPECIFICATIONS R7DA Series 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units 5.4 ISMRE Commercial System 81% Steady State Efficiency Standard Features Fits Pre-Existing Curbs High-Efficiency Low

More information

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS 7 Rosemex Products 97 VENTILATION CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS 2 INTRODUCTION Rosemex "Penthouse" units are essentially outdoor mechanical rooms. They group in one compact weather proof outdoor

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information

HVAC LEGEND HVAC ABBREVIATIONS PLUMBING LEGEND PLUMBING ABBREVIATIONS PRELIMINARY NOT FOR CONSTRUCTION

HVAC LEGEND HVAC ABBREVIATIONS PLUMBING LEGEND PLUMBING ABBREVIATIONS PRELIMINARY NOT FOR CONSTRUCTION GENERAL NOTES SPECIFICATIONS LEGEND SYMBOL DESCRIPTION ABBREV. SYMBOL DESCRIPTION ABBREV. SYMBOL DESCRIPTION ABBREV. ABBREVIATIONS PLUMBING LEGEND SYMBOL DESCRIPTION ABB. SYMBOL DESCRIPTION ABB. SYMBOL

More information

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

EXHAUST FAN SCHEDULE

EXHAUST FAN SCHEDULE DUCTWORK SCHEDULE CONCEALED SUPPLY AIR RECTANGULAR, RTU CONCEALED SUPPLY AIR RECTANGULAR, ERV CONCEALED SUPPLY AIR ROUND, RTU CONCEALED SUPPLY AIR ROUND, ERV EXPOSED SUPPLY AIR ROUND RUNOUTS RETURN AIR

More information

Dear Concessionaire,

Dear Concessionaire, Dear Concessionaire, In order to provide a comprehensive review & inspection of the Vendor application please review the following as guidance to a complete application and preparedness for inspection.

More information

CL64T INDUSTRIAL TOTE WASHER

CL64T INDUSTRIAL TOTE WASHER Item # Quantity C.S.I. Section 11400 STANDARD FEATURES Selectable Speed 4, 5, 6 feet/minute Opti-RinSe system Rapid return conveyor drive mechanism Insulated hinged double doors with door interlock switches

More information

SECTION COMMERCIAL-KITCHEN HOODS

SECTION COMMERCIAL-KITCHEN HOODS SECTION 23 38 13 COMMERCIAL-KITCHEN HOODS SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. 2. Delete other items or paragraphs in the section that are not applicable and renumber

More information

The D1000. Typical Specifications: activate the mechanical fire suppression system. (pressurized potassium citrate / potassium acetate mix)

The D1000. Typical Specifications: activate the mechanical fire suppression system. (pressurized potassium citrate / potassium acetate mix) Fan 10 Ductwork Cabinet 7 to 10 adaptor set Range Hood Fan D1000-I_-DF Air Flow Plenum Ready Supply Cable to Fan 120VAC Input Supply Line 120VAC Output Line, Power Disconnect D1000-I_-DF-NFPA101 12 Ductwork

More information

Direct Fired Heater Model AD Specification

Direct Fired Heater Model AD Specification Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI

More information

PARTS LIST. SERVICE PARTS LIST WVG-136 Ventless Griddle with or without Roll Warmer CONTENTS

PARTS LIST. SERVICE PARTS LIST WVG-136 Ventless Griddle with or without Roll Warmer CONTENTS WELLS BLOOMFIELD A Division of Carrier Commercial Refrigeration, Inc. 2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439 telephone: 888-492-2782 fax: 888-492-2783 www.wellsbloomfield.com PARTS LIST 502 SERVICE

More information

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You TGIFR IFR Indirect Fired Gas Heating Systems Technical Guide for: Outdoor Rooftop Mounted Units To 46,000 CFM And 4,000 MBH Output Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be

More information

SHOE PALACE HUNTINGTON PARK M.200

SHOE PALACE HUNTINGTON PARK M.200 M.200 SPLIT SYSTEM CONDENSING UNIT SCHEDULE MARK SERVICE MODEL NO. COOLING DIMENSIONS ELECTRICAL REMARKS CAPACITY AMBIENT DB REFRIGERANT LENGTH WIDTH HEIGHT WEIGHT VOLT/PHASE MCA MOP (MBH) (DEG F) (IN)

More information

GA Gas Unit Heater Assemblies Technical Guide

GA Gas Unit Heater Assemblies Technical Guide TGGA-2 GA Gas Unit Heater Assemblies Technical Guide INDIRECT-FIRED GAS HEATING ASSEMBLIES FOR LARGE OPEN SPACES AND DOOR HEATING APPLICATIONS S ince 7, the L.J. Wing Company has been a leader in providing

More information

REPAIR PART DIAGRAMS. Pages: 1-6

REPAIR PART DIAGRAMS. Pages: 1-6 REPAIR PART DIAGRAMS PRODUCT: MODEL: DISHWASHER LL S The information included in this Ariston Spare Parts List may change without notice please see our web site www.usservicenet.com for updates, corrections

More information

ADF/ADFH 300 and 500

ADF/ADFH 300 and 500 MODEL ADF/ADFH DIRECT-FIRED SYSTEMS TECHNICAL DATA Four Sizes - 300, 500, 700, 1200 Horizontal Configuration with Full Curb Cap Base Horizontal or Vertical (down) Discharge Indoor/Outdoor Installation

More information

Ventless Operation Supplement GBF-D-VH

Ventless Operation Supplement GBF-D-VH Operations & Service Manual GBF-5D-VH GBF-50D-VH Ventless Operation Supplement GBF-D-VH Giles Enterprises, Inc. An ISO900 Registered Company Committed to Quality 750 Gunter Park Drive West Montgomery,

More information

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving Product Data ROOMTOP 50AH024-096 Standard Efficiency Horizontal Indoor Single-Package Cooling Units with PURON Refrigerant (R-410A) 2 to 8 Nominal Tons The 50AH single-package cooling units feature: ASHRAE

More information

Chilled Water DOAS Fan Powered Terminal Units

Chilled Water DOAS Fan Powered Terminal Units Chilled Water DOAS Fan Powered Terminal Units CHILLED WATER DOAS FAN POWERED TERMINAL UNITS DOAS TERMINAL UNITS FEATURES AND BENEFITS MINIMUM VENTILATION CONTROL The DOAS unit provides the Designer, Owner

More information

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS Technical Guide SPLIT-SYSTEM EVAPORATOR BLOWERS 7-1/2 and 10 NOMINAL TONS LA090 & LA120 DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

Low Wall Back Shelf Exhaust Canopy

Low Wall Back Shelf Exhaust Canopy ITEM NO. 710 Powerline Road Suite H Deerfield Beach, FL 33442 (954) 570-9860 (800) 322-8730 FAX (954) 570-9865 Low Wall Back Shelf Exhaust Canopy Model LW APPLICATION Wall mounted canopy style ventilator

More information

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

CATALOG. SKYPAK Self-Contained Heating/Cooling Units CATALOG SKYPAK Self-Contained Heating/Cooling Units FORM SK145.00-EG6 (1211) TABLE OF CONTENTS SKYPAK Self-Contained Heating/Cooling Units Introduction...3 Product Overview...3 Nomenclature...4 SKYPAK

More information

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check

More information

The D1000. Typical Specifications: Standard Options*: Model: D1030-I_-DF Spec & Submittal Version 2.3 D1000-I_-DF D1000-I_-DF-NFPA101

The D1000. Typical Specifications: Standard Options*: Model: D1030-I_-DF Spec & Submittal Version 2.3 D1000-I_-DF D1000-I_-DF-NFPA101 Fan 10 Ductwork Cabinet 7 to 10 adaptor set Range Hood Fan D1000-I_-DF Air Flow Plenum Ready Supply Cable to Fan 110VAC Supply Cable Power Disconnect Cable D1000-I_-DF-NFPA101 12 Ductwork Cabinet 7 to

More information

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium

More information

The D1000. Typical Specifications: Standard Options*: Model: D1036-F Spec & Submittal Version 2.2 D1000-F_ D1000-F_-NFPA101

The D1000. Typical Specifications: Standard Options*: Model: D1036-F Spec & Submittal Version 2.2 D1000-F_ D1000-F_-NFPA101 Range Hood Cabinet Range Hood Air Flow D1000-F_ 110VAC Supply Cable Power Disconnect Cable D1000-F_-NFPA101 Cabinet Air Flow Fan Box (NFPA101 rev) 110VAC Supply Cable Power Disconnect Cable Width Fan Type

More information

FRESH FROM THE KITCHEN FRESH FROM THE KITCHEN

FRESH FROM THE KITCHEN FRESH FROM THE KITCHEN PLUMBING SCOPE OF WORK - DRAINS KEC TO PROVIDE: - ALL TWIST WASTE VALVES & BASKET DRAINS, AS REFLECTED ON EQUIPMENT SCHEDULE, - PIPE CONDENSATE DRAIN FOR WALK IN COOLER WITH 3/4" COPPER TUBING, WITH NECESSARY

More information

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents TABLE OF CONTENTS A complete line of commercial, industrial, and residential heating equipment is offered. This catalog describes in detail the gas-fired, gravity and power vented, commercial/ industrial

More information

CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO

CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN HSROG ML-111148 A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 43003 (June 2001) HOT SECTION 26 OVEN TOP SECTION

More information

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons DVPEC Multi-Position, Variable-Speed air handler Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow

More information

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Construction Standards Page 233423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified

More information

Types of Detection. Fusible Link Detection - Most Common

Types of Detection. Fusible Link Detection - Most Common Types of Detection Fusible Link Detection - Most Common Types of Detection Electric Detection Types of Detection Pneumatic Detection-Tubing Pneumatic Tubing 3 Year Service life Survey Hazard 1) List all

More information

CT CABINET AND UTILITY METERING WELL AND BOOSTER PUMP CONTROL 12"x12" WIREWAY 200A MCB 200A, 120/208V, 3Ø, 4W BOARD TVSS CIA ALARM 400A, DOUBLE-THROW SWITCH PORTABLE GENERATOR CONNECTION ENCLOSURE EXISTING

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 482886 Models DG, DGX, TSU, VSU Direct Gas Make-Up Air and Industrial Space Heat Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read

More information

FCI500/600/FVI500/FCL/FVL600/FCQ-700 Installation and Maintenance Manual

FCI500/600/FVI500/FCL/FVL600/FCQ-700 Installation and Maintenance Manual FCI500/600/FVI500/FCL/FVL600/FCQ-700 Installation and Maintenance Manual FAN POWERED TERMINALS Receiving Inspection Prior to removing the shipping material, visually inspect the packing materials. There

More information

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV DVPVC Multi-Position, Variable-Speed Air Handler Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications...3

More information

CL44eR DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE. Item # Quantity C.S.I.

CL44eR DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE. Item # Quantity C.S.I. Item # Quantity C.S.I. Section 11400 DISHWASHER STANDARD FEATURES Energy recovery 202 racks per hour Opti-RinSe system 30 KW electric booster heater Rapid return conveyor drive mechanism Insulated hinged

More information

GOLDEN TEMPLE AMRITSAR SPECIFICATIONS FOR KITCHEN EQUIPMENT

GOLDEN TEMPLE AMRITSAR SPECIFICATIONS FOR KITCHEN EQUIPMENT GOLDEN TEMPLE AMRITSAR SPECIFICATIONS FOR MODULAR KITCHEN EQUIPMENT Dated: 12/08/2014 ARCHITECT HABITAT ARCHITECTS 1777, MAHARAJ NAGAR, LDH. CLIENT SHIROMANI GURDWARA PARBANDHAK COMMITTEE. INDIA - 1st

More information

FIRE ALARM: BY OTHERS, IF REQUIRED.

FIRE ALARM: BY OTHERS, IF REQUIRED. x x x x x x OS LIGHTING S FLUORESCENT LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. CAPITAL LETTER DENOTES TYPE, LOWER CASE LETTER DENOTES SWITCH LEG. FLUORESCENT STRIP LIGHT FIXTURE,

More information

LABEL PLEASE NOTE: ALL APPLICATIONS AND SITE PLANS MUST BE COMPLETED IN BLACK OR BLUE INK ONLY

LABEL PLEASE NOTE: ALL APPLICATIONS AND SITE PLANS MUST BE COMPLETED IN BLACK OR BLUE INK ONLY STAFF USE ONLY Thurston County Resource Stewardship 2000 Lakeridge Dr. S.W. Olympia, WA 98502 (360)786-5490 / (360)754-2939 (Fax) TDD Line (360) 754-2933 Email: permit@co.thurston.wa.us www.co.thurston.wa.us/permitting

More information

FIRE ALARM: BY OTHERS, IF REQUIRED.

FIRE ALARM: BY OTHERS, IF REQUIRED. x x x x x x OS LIGHTING S FLUORESCENT LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. FLUORESCENT STRIP LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. WALL BRACKET FLUORESCENT

More information

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED (491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

Wiring Diagrams DIAGRAM INDEX

Wiring Diagrams DIAGRAM INDEX 50TFF004-014 Single Package Rooftop Electric Cooling Units Wiring Diagrams DIAGRAM INDEX UNIT LABEL DIAGRAM Unit 50TFF Voltage-Phase-Hertz Type Label Diagram Figure No. 208/230-1-60 Schematic/Component

More information

Project Name: Project Address: Installer Name: Installer Address: Date of Inspection:

Project Name: Project Address: Installer Name: Installer Address: Date of Inspection: FIRE DEPARTMENT Kitchen Range Hood Fire Suppression System Acceptance Test Project Name: Project Address: Installer Name: Installer Address: Date of Inspection: DOCUMENTATION NO Plans have been reviewed

More information

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 9001EXP Alarm No. 2080203(24)

More information

Make-Up Air Systems. Performance. Model DGK, DG, DGX

Make-Up Air Systems. Performance. Model DGK, DG, DGX DGK, DG, DGX 96 Make-Up ir Systems Direct Fired Gas Heat DGK-15-25 DG-10-20 -30 DGX-12-22 -32 *DGX with PDX-12-22 -32 est vailable Program 5 Days 10 Days 15 Days * est vailable based on size and capacity

More information

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and

More information

The D1000. Typical Specifications: Standard Options*: Model: D1030-R Spec & Submittal Version 2.1 D1000-R_ D1000-R_-NFPA101

The D1000. Typical Specifications: Standard Options*: Model: D1030-R Spec & Submittal Version 2.1 D1000-R_ D1000-R_-NFPA101 Cabinet Range Hood D1000-R_ Air Flow 110VAC Supply Cable Power Disconnect Cable D1000-R_-NFPA101 Cabinet Range Hood Air Flow Fan Box (NFPA101 rev) 110VAC Supply Cable Power Disconnect Cable Width Fan Type

More information

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

Slow drying Thermostat What is temperature set at on control. Check for adequate makeup air (1.5 sq. Ft.)

Slow drying Thermostat What is temperature set at on control. Check for adequate makeup air (1.5 sq. Ft.) Tumbler turns ignition sparks no flame Gas supplymake sure gas supplyis working Gas pressure Make manometer check of gas pressure for 3.5" W.C. or more at supply side Spark electrode Gas valve Check electrode

More information

MODEL: JRSVH SERIES JEAN S RESTAURANT SUPPLY 426 SOUTH STAPLES CORPUS CHRISTI, TEXAS PH: (361)

MODEL: JRSVH SERIES JEAN S RESTAURANT SUPPLY 426 SOUTH STAPLES CORPUS CHRISTI, TEXAS PH: (361) C US FILE#:MH48178 MODEL: JRSVH SERIES JEAN S RESTAURANT SUPPLY 426 SOUTH STAPLES CORPUS CHRISTI, TEXAS 78401 PH: (361)884-9800 WWW.JEANSRESTAURANTSUPPLY.COM UL Standard for Safety for Exhaust Hoods for

More information

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible Contents MBVC Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Airflow Data... Heat Kit Data...

More information

Control Panel For Water Wash Hoods AM2

Control Panel For Water Wash Hoods AM2 Control Panel For Water Wash Hoods AM2 For further information Call: (919) 554-1025 Or Fax: (919)554-1525 Aqua-Matic 117 Franklin Park Ave. Youngsville, NC 27506 TABLE OF CONTENTS AQUA-MATIC LIMITED WARRANTY

More information

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check

More information

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

AIR HANDLER DESIGN WORK SHEET

AIR HANDLER DESIGN WORK SHEET AIR HANDLER DESIGN WORK SHEET JOB Project: Date Representative Unit Model No. of Units Unit Tag(s) UNIT CONSTRUCTION UNIT ARRANGEMENT: [ HORIZ VERT] [ INDOOR OUTDOOR] [ BASE MTD CEILING HUNG CURB MTD]

More information

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You. TGIF- Indirect Fired Heating Systems Technical Guide for: IF Indoor Installations IFW Outdoor Installations Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide In the business of

More information

28 1/2"* 72.4 cm. (*28 1/2 " to include hinges.) 41 3/4" 106 cm. 27" 68.6 cm. 28 1/2"* 72.4 cm. (includes hinges.) 28 1/2"* 41 3/4" 106 cm

28 1/2* 72.4 cm. (*28 1/2  to include hinges.) 41 3/4 106 cm. 27 68.6 cm. 28 1/2* 72.4 cm. (includes hinges.) 28 1/2* 41 3/4 106 cm Commercial Single Load Dryers 28 1/2"* 72.4 cm PRODUCT DIMENSIONS (*28 1/2 " to include hinges.) 28 1/2"* 72.4 cm (*28 1/2 " to include hinges.) Models MDE/MDG21PD MDE/MDG21PS MDE/MDG21PR MDE/MDG21PN 43

More information

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil UNIT HEATER CATALOG COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS FUEL Natural Gas Propane Fuel Oil CAPACITIES 25-1,200 MBH 80% - 93% Thermal Efficiency 380-16,750 CFM AIR DELIVERY Propeller

More information

Installation and Maintenance Manual Please retain this manual for future reference.

Installation and Maintenance Manual Please retain this manual for future reference. 342 N. Co. Rd. 400 East Valparaiso, IN 46383 219-464-8818 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. Electric Construction Heaters

More information

Canning Shed/Facility Equipment Specifications

Canning Shed/Facility Equipment Specifications Canning Shed/Facility Equipment Specifications Item Qty Description 1 1 ea WALK IN COOLER Fast Trak Indoor One Compartment Walk In, 8' x 8' x 7' 7" H, compartments, cooler with smooth aluminum interior

More information

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h / Heating Input: 40,000 120,000 BTU/h Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 flow Specifications...7 Wiring Diagram...10

More information

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY 24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY 11/12/2012 Rev. 10 Pollution Control Unit PCU CORE CONNECTIONS, 3/8" NPT CONNECTION, ONE PER MODULE LINE FROM PACKAGE MUST BE BRANCHED AND ADAPTED TO EACH

More information

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... 3 Dimensions...

More information

08/17/2011 Rev. 4 PULL STATION EXHAUST HOOD 10 TO 20 FEET FROM HOOD LOCATE ONE NEAR EVERY POINT OF EGRESS FROM HOOD

08/17/2011 Rev. 4 PULL STATION EXHAUST HOOD 10 TO 20 FEET FROM HOOD LOCATE ONE NEAR EVERY POINT OF EGRESS FROM HOOD 24V CORE TOTAL FLOOD PROTECTION INSTALLATION SUMMARY CORE WATER LINE- 30 TO 70 PSI OPERATING PRESSURE, 90 PSI MAX STATIC PRESSURE, 1.5 GPM PER FOOT OF HOOD 3/4 INCH NPT FITTING, CONNECTED TO SUPERVISED,

More information

wiring diagrams AIR-COOLED CONDENSING UNITS SPLIT-SYTEM HEAT PUMP UNIT UNITS PRODUCED AFTER SEPTEMBER 1996 DIAGRAM INDEX

wiring diagrams AIR-COOLED CONDENSING UNITS SPLIT-SYTEM HEAT PUMP UNIT UNITS PRODUCED AFTER SEPTEMBER 1996 DIAGRAM INDEX wiring diagrams AIR-COOLED CONDENSING UNITS SPLIT-SYTEM HEAT PUMP UNIT Cancels: New 569C Sizes 072 to 120 576B Sizes 090-120 575A Size 090 WD 569C.72.4 8/15/02 UNITS PRODUCED AFTER SEPTEMBER 1996 DIAGRAM

More information

CL64e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

CL64e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE Item # Quantity C.S.I. Section 11400 DISHWASHER STANDARD FEATURES 342 racks per hour Opti-RinSe system Rapid Return Conveyor Drive Mechanism Insulated hinged double doors with door interlock switches 19.5

More information

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

CLPS66e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

CLPS66e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE Item # Quantity C.S.I. Section 11400 DISHWASHER STANDARD FEATURES 202 racks per hour Opti-RinSe system Rapid Return Conveyor Drive Mechanism Insulated hinged double doors with door interlock switches 19.5

More information

Gas-Fired Indoor and Outdoor Duct Furnaces

Gas-Fired Indoor and Outdoor Duct Furnaces July, 2008 Gas-Fired Indoor and Outdoor Duct Furnaces INDOOR GRAVITY VENTED DFG, DBG, DCG INDOOR SEPARATED COMBUSTION DFS, DBS, DCS OUTDOOR GRAVITY AND POWER EXHAUSTED H Series table of contents A complete

More information

COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 20 TONS

COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 20 TONS Product Specifications COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER S, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without modification.

More information

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS 48HJ-13SB Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT

More information

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

More information

Installation, Operation and Maintenance Manual **FOR YOUR SAFETY**

Installation, Operation and Maintenance Manual **FOR YOUR SAFETY** MODEL IGX Make-Up Air Unit Installation, Operation and Maintenance Manual Part # 462876 **FOR YOUR SAFETY** If you smell gas: 1. Open windows. 2. Don t touch electrical switches. 3. Extinguish any open

More information

All the products you need for. Engineered Kitchen Ventilation Systems.

All the products you need for. Engineered Kitchen Ventilation Systems. All the products you need for Engineered Kitchen Ventilation Systems. [ 3 ] December 2007 Comfortable energy efficient kitchen ventilation starts here. Accurex specializes in ventilation comfort for restaurants

More information

CLe-series Dishwashers

CLe-series Dishwashers CLe-series Dishwashers Blower-dryer electric (CLe SERIES) ML-138211 ML-138212 ML-138213 ML-138214 electric (CLeR SERIES) ML-138325 ML-138326 ML-138327 ML-138328 STEAM (CLe SERIES) ML-138226 ML-138227 ML-138228

More information

DISPOSER CONTROL CENTER

DISPOSER CONTROL CENTER DISPOSER CONTROL CENTER Installation Manual Model CC-101K WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION indicates a hazardous situation

More information

GRILLE, REGISTER AND DIFFUSER SCHEDULE

GRILLE, REGISTER AND DIFFUSER SCHEDULE ROOFTOP UNIT SCHEDULE (NATURAL GAS HEAT) MARK MANUFACTURER MODEL SUPPLY FAN COOLING COIL HEAT EXCHANGER MIN. MIN. MCA MOCP V/PH WEIGHT NOTES FAN CFM MIN ESP REFR. TH SH EAT LAT MIN. OUTPUT MIN. EFF. NOM.

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

SAS Steadyair Make-Up Air Units Technical Guide

SAS Steadyair Make-Up Air Units Technical Guide TGSAS-3 SAS Steadyair Make-Up Air Units Technical Guide A COMPLETE AIR TEMPERING PACKAGE FOR COMMERCIAL, INSTITUTIONAL, AND INDUSTRIAL APPLICATIONS S ince 1875, the L.J. Wing Company has been a leader

More information