2nd International Workshop. Labyrinth and Piano Key Weirs Paris - Chatou, France November 2013

Size: px
Start display at page:

Download "2nd International Workshop. Labyrinth and Piano Key Weirs Paris - Chatou, France November 2013"

Transcription

1 2nd International Workshop on Labyrinth and Piano Key Weirs Paris - Chatou, France November 2013 Improvement of the form of labyrinth weirs Ahmed OUAMANE François LEMPERIERE Laboratory of hydraulic developments and environment University of BISKRA (ALGERIA)

2 Upstream Upstream W Downstream W Downstream Linear Weir Labyrinth Weir - The labyrinth weir is often used when the width of the weir or the maximum head is limited. - The cost of the labyrinth weir is relatively low compared to weirs with gates, this led to its use simultaneously to increase the storage and discharge capacity of the spillway.

3 The geometry in the plane of the crest of the labyrinth weir is characterized by an discontinuous centerline. This thus results in a complex flow mode (Lux III & Hinchliff, 1985), which is considered as three-dimensional.

4 Upstream Disturbance Middle Jet area Downstream 0 ld lc l c : Length of crest l d : Length of distarbance ljc: Length of middle jet Flow is characterized by the length disturbance and the length of the middle jet

5 The non-linear shape of the crest of the labyrinth weir creates a three-dimensional flow disturbed at each discontinuity of the axis of the weir. These flow conditions cause a reduction in the performance of labyrinth weir. Qc 2 3 Cm 2 3 3/ 2 n ld 2 ghcn n ( lc ld ) 2 gh 3/ 2 cn Cm: Coefficient of disturbance 2 3/ n 2gh 2 cn Qc lc (1 Cm ) l 3 C m ( l ) (l): Discharge coefficient of the disturbance flow n: Discharge coefficient of the two-dimensional flow n d The reduction of the crest length caused by the disturbance

6 The importance of the reduction of discharge coefficient is dependent on the head on the weir and the importance of the angle of the corner. (Indlekofer & Rouve ) Although the labyrinth weir has been thesubject of several applications and it has proved his efficiency, some changes in classic shape can have a positive effect on the hydraulic and economic performance.

7 The main parameter that promotes flow disturbance and therefore reduces the performance of the labyrinth weir, corresponds to the discontinuity of the weir crest. Thus, to reduce the effect of this discontinuity, a profiling of the front wall of the labyrinth weir can have a positive effect on the hydraulic efficiency. A. Labyrinth weir model with rounded front wall B. Model labyrinth weir with flat front wall

8 The comparison of results obtained on two models of weir noted that the design of a rounded shaped entrance leads to an improving the performance of about 10%. This can be explained on the one hand, by the profiled shape of entrance which facilitates the flow on either side of the front wall along the latter. On the other hand, the rounded shape eliminates the discontinuity points and thus reduces the effect of the disturbance at the top of the weir. 2.5 Trapezoidal labyrinth weir with a rounded front wall 2 Trapezoidal labyrinth weir with a flat front wall 1.5 Cw H*/P Flow coefficients according to the shape of the entrance of labyrinth weir L / W = 3.9, W / P=1

9 As reported by the literature, the labyrinth weir is an economical solution as the specific discharge is less than 50 m3/s/m. Beyond this value the labyrinth weir requires great height walls which implies a greater thickness of walls and greater reinforcement. Labyrinth spillway at Labyrinth spillway at Ute Dam, New Mexico

10 It is possible that the design of the labyrinth weir with a partial filling of the alveoli by ordinary concrete leads to a reduction of the additional cost, this implies a reduction in the free part of the wall height and thus provides a low wall thickness and therefore a small reinforcement of the structure. A B B P/5 B P a 2a 1.2P A-A W A Wt B 3P/4 B-B P Schematic of labyrinth weir with entrance profiled and alveoli partially filled

11 The experiment of two models showed that the flow over the weir partially filled alveoli and rather airy and stable for low charge, which is not the case for weirs without filling alveoli. This justifies the offset between the two curves of discharge coefficient for the range of values of the relative head H*/P < Profiled shape with a partial filling of alveoli Profiled shape without filling of alveoli Cw H*/P Discharge coefficient of labyrinth weir with profiled shape L/W = 3.9 W / P=1

12 The alveoli filling has no effect than for the low heads. For the range of values of H* / P> 2.5, the two weirs have the same hydraulic performance. So, the partial filling of the alveoli has no effect on the performance of labyrinth weir and helps to avoid the problem of aeration for low heads over the weir Trapezoidal shape with a partial filling of alveoli Trapezoidal shape without filling of alveoli Cw H*/P H/P

13 Thus, it is possible for the greater specific discharges than 50m 3 /s/ml to design the labyrinth weir with the alveoli partially filled in ordinary concrete this gives an economic structure while maintaining hydraulic performance similar to that of classical labyrinth weir without a filling of alveoli.

14 It is possible that other shape in plan can be effective as the trapezoidal and triangular shapes often used in existing dams. Thus, for practical, economic and hydraulic performance reasons, we may adopt a rectangular shape in plan with a profiled entrance and a slab of the downstream alveoli as a stairs and that of the upstream alveoli partially inclined. These structural particularities can improve the performance of labyrinth spillway and reduce the cost of construction. The choice of the rectangular shape allows vary the widths of the upstream and downstream cells to obtain a ratio of width which allows for better hydraulic efficiency and reduced cost.

15 The partial filling of alveoli upstream and downstream of ordinary concrete can reduce the thickness of the walls and the quantity of steel, because the free part of the walls is reduced. The design of the slab of the downstream alveoli as stair step, also help to dispel some of the energy. 2 Upstream 1 b a 2 Downstream w 1 B B 2P/3 1 1 P 2P/3 2 2 P Rectangular labyrinth weir with shaped entrance and a partial filling of alveoli

16 The profiled shape of the entrance and the inclination of part of the slab of the upstream alveoli can improve the flow conditions at the entrance of the labyrinth; therefore the weir becomes more efficient.

17 Often the labyrinth spillway is designed with a trapezoidal shape in plan that is repeated periodically. It is possible that the labyrinth weir take another geometric shape that can be as effective as the trapezoidal shape. The choice of a rectangular shape can be as effective of viewpoint, hydraulic and economic performance and its construction is easiest, especially when it is used as a dam weir of low height in the rivers.

18 The experiment of two models of labyrinth weirs, successively, trapezoidal and rectangular showed that the rectangular shape can be as effective as the trapezoidal shape and even more effective for the relative heads lower than 0.5, corresponding to the practical range for design weirs labyrinth. 1,6 1,4 1,2 Rectangular shape L/W=4 Trapezoidal shape L/W=4 1,0 Cw 0,8 0,6 0,4 0,2 0,0 0,0 0,2 0,4 0,6 0,8 1,0 H*/P Discharge coefficient according to the shape of the labyrinth weir

19 Usually the labyrinth weirs are designed with vertical walls. This arrangement requires a substantial length of the side walls to achieve effective performance. This limits the application of the labyrinth weir and does not allow its installation ti on most crests of concrete dams. It is possible to reduce the length of the base of the side walls without affecting the length of the sill of labyrinth weir. This is feasible by using a part of the length of the side walls in overhang. A B B B r B P S a/2 b a b a/2 A B bp A-AA bp B-BB

20 Experimental result obtained in labyrinth weir with downstream overhang and an inclined slab showed that this weir configuration provides a better performance which can be three times that of a linear weir for medium heads Labyrinth weir with overhang Linear weir 1.2 Cw H*/P Discharge coefficients of labyrinth weir with a downstream overhang and linear weir

21 The disposition of the inclined slab between the side walls leads to reduction in the average height of the weir. Thus, the walls of the weir become less thick than the weir with horizontal slab due to the reduction of forces applied to the walls, which reduces the quantity of steel reinforcement. However, the volume of the concrete of the slab becomes larger. The use of inclined slab minimizes the effect of turbulence at the weir crest, producing a flow of the threads of liquid which are more or less regular.

22 The application of the previously mentioned improvements to the labyrinth weir can lead to a form of economic weir and of a better hydraulic performance. The piano keys weir (PK-Weir) brings all these advantages and other, Th th PK W i Thus, the PK-Weir was born

23 The Piano Key Weir can be used for new dams or existing dams that require increase in the spillway capacity and / or storage capacity. It can be placed on small sections of existing or new concrete dams and allows discharging of specific flows up to 100 m3/s/m and. multiply by at least three the discharge weir Creager (Lempérière & Ouamane, 2003). The final configuration of the PK-Weir was determined following testst onphysical models, which h helped define the geometry of the PK-Weir (Ouamane & Lempérière, 2006), which is based on: - A rectangular layout. - An inclined slab of the upstream and downstream alveoli. - A base length reduced through the use of overhang. - A reduced width of rectangular elements

24 Many study and test were done since 2002 in university of Biskra (Algeria) allowed to define two forms of PK-Weir, the first with an upstream and downstream overhangs (model A) and the second with only an upstream overhang (model B)

25 Piano Keys Weir type A

26 Piano Keys Weir type B

27 PK-Weir type A The P.K.Weir type A was studied in a extensive way in Expérimental results showed that: hangover slopes between 2/1 and 3/2 width of the inlets 1.2 times that of outlets e Upstream hangovers are more efficient then downstream hangovers. The hydraulic shape of the entrance is important. For H between 3 to 5 m, the ratio N=L/W should be about 4 to 6. For smaller H, the ratio N could be more important.

28 If h is the head of water, the specific flow is close to 4hH0.5 for the heights most often used (0.25H<h<1.5H). The outflow of a traditional Creager crest is hence multiplied by almost 4 when h = 0.25 H, by 3 when h = 0.4H and by 2 when h is around 0.8H. The increase in specific flow (in m3/s/m) is nearly 1.8 H1.5. A saving in head of water (i.e storage) of nearly 0.5H is obtained.

29 Tests result of experiments showed that the flow is related to the head on the PK-Weir: For low and medium heads, the flow is defined by two discharging nappe, the first in the form of a jet of the bottom and the second in the form of a screen more or less thin. For the high heads the two nappes become interdependent constituting so a single nappe.

30 The discharge of P.K.Weir is superior to that of Creager weir. For the heads lower than the half of the height of the weir (h/p < 0,5), it is from 3,5 to 2,5 times. For heads equal or superior to the height of the weir, it is in order of 1,5 times. This shows thatt the P.K.Weir can be a solution to evacuate high discharges under low heads P.K.Weir type B Creager Weir Q (l/s) 80 Increase 60 discharge Saving head ,00 2,00 4,00 6,00 8,00 10,00 12,00 14,00 16,00 H* (cm)

31 P.K.Weir type B P.K.Weir type A P.K.Weir type B Creager Weir Q (l/s) ,00 2,00 4,00 6,00 8,00 10,00 12,00 14,00 16,00 H* (cm) P.K.Weir type B allows an increase of discharge about 10 % with regard to the P.K.Weir type A. This result shows that model B can be a solution for large discharges.

32 2,0 18 1,8 1,6 1, 4 L/W=4 W/P=1,67 a/b=1,5 L/W=4 W/P=1,25 a/b=1,5 L/W=4 W/P=1,0 a/b=1,5 Cw 1,2 1,0 0,8 0,6 0,4 0,2 0,0 00 0,0 01 0,1 0, 0, 0, 05 0,5 06 0,6 07 0,7 H*/P Discharge coefficient according to the ratio of vertical aspect W/P The increase of the height of 25% increases the capacity of weir from 5 to 8%.

33 Q (l/s) L/W=8 P/B=0,36 a/b=1,5 L/W=6 P/B=0,36 a/b=1,5 / /, 2,0 L/W=4 P/B=0,36 a/b=1,5 0 0,0 2,0 4,0 6,0 8, 10,0 12,0 14,0 16,0 H* (cm) Cw 1,5 1,0 0,5 L/W=6 P/B=0,5 a/b=1,5 L/W=4 P/B=0,5 a/b=1,5 0,0 0,0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 H*/P Discharge and Discharge coefficient according to ratio L/W For slope of aprons of the P.K.Weir type B lower than 0,5 the variation of the ratio L/W has no effect on the capacity of Weir. TheincreaseoftheratioL/Wfrom4to6allowstoincreasethe capacity of weir about 10 % for the medium relative heads.

34 2,5 2,0 L/W=6 W/P=1,1 a/b=1,2 L/W=6 W/P=1,1 a/b=1,5 / /b L/W=6 W/P=1,1 a/b=0,67 Cw 1,5 1,0 0,5 0,0 0,0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 H*/P Discharge coefficient according to the width of the inlet and outlet The optimum of relative width is near a/b=1,2. It is possible for the same cost to increase the width of the inlet of 10 % and to reduce consequently the width of the outlet. This increases efficiency about 5 % without any additional expence.

35

36 PKWeir: Goulours Dam (EDF 2006) France

Pollutant Removal Benefits

Pollutant Removal Benefits Bioswales Bioswales Similar to biocells, but have a slight, but positive grade toward an outlet Designed to convey the WQv event at very low velocities Promote filtration through native vegetation, infiltration

More information

CEE:3371 Principles of Hydraulics and Hydrology Project #2 Flow Measurement with a Weir

CEE:3371 Principles of Hydraulics and Hydrology Project #2 Flow Measurement with a Weir CEE:3371 Principles of Hydraulics and Hydrology Project #2 Flow Measurement with a Weir Problem Statement The Iowa DNR plans to monitor a proposed prairie restoration project in eastern Iowa as an experiment.

More information

Compression of Fins pipe and simple Heat pipe Using CFD

Compression of Fins pipe and simple Heat pipe Using CFD Compression of Fins pipe and simple Heat pipe Using CFD 1. Prof.Bhoodev Mudgal 2. Prof. Gaurav Bhadoriya (e-mail-devmudgal.mudgal@gmail.com) ABSTRACT The aim of this paper is to identify the advantages

More information

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM Hantz, D., Gulyas, G., Bensafi, A. Centre Technique des Industries Aéraulique et Thermique (CETIAT) BP 2042

More information

Development of Gas-Liquid Two-Phase Flow Distributor for Improving Energy Efficiency in Air-Conditioners

Development of Gas-Liquid Two-Phase Flow Distributor for Improving Energy Efficiency in Air-Conditioners 90 Development of Gas-Liquid Two-Phase Flow Distributor for Improving Energy Efficiency in Air-Conditioners YASUTAKA AOKI *1 TAKAHIDE ITO *2 GENTO ICHIKAWA *1 TAKAO ITAMOTO *3 As a means to reduce environmental

More information

Analysis of Pullout Resistance of Soil-Nailing in Lateritic Soil

Analysis of Pullout Resistance of Soil-Nailing in Lateritic Soil Analysis of Pullout Resistance of Soil-Nailing in Lateritic Soil B,L.A. Isaka 1, B.C. Madushanka 1 and N.H. Priyankara 1 1 Department of Civil and Environmental Engineering Faculty of Engineering University

More information

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5 IJAET International Journal of Application of Engineering and Technology ISSN: 2395-3594 Vol-1 No.-2 CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys

More information

OPTIMISATION OF NOZZLE ARRANGEMENTS ON DESCALING HEADERS. Jürgen W. Frick Lechler GmbH D Metzingen / Germany

OPTIMISATION OF NOZZLE ARRANGEMENTS ON DESCALING HEADERS. Jürgen W. Frick Lechler GmbH D Metzingen / Germany OPTIMISATION OF NOZZLE ARRANGEMENTS ON DESCALING HEADERS Jürgen W. Frick Lechler GmbH D-72555 Metzingen / Germany E-mail : frju@lechler.de ABSTRACT The demand for improved product quality and increased

More information

Investigating the bottom free surface nappe (ogee profile) across a sharp crested weir caused by the flow in an asymmetrical approach channel

Investigating the bottom free surface nappe (ogee profile) across a sharp crested weir caused by the flow in an asymmetrical approach channel Investigating the bottom free surface nappe (ogee profile) across a sharp crested weir caused by the flow in an asymmetrical approach channel S J van Vuuren, G L Coetzee, C P R Roberts The shape of an

More information

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation Cooling and heating systems Static cooling ceiling system SKS-/3 DS 10 E 01.010 Static cooling ceiling system SKS-/3 Main features Preliminary remarks / Applications 3 Main dimensions and materials 3 Construction

More information

(Refer Slide Time: 00:00:40 min)

(Refer Slide Time: 00:00:40 min) Refrigeration and Air Conditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur Lecture No. # 10 Vapour Compression Refrigeration Systems (Refer Slide

More information

Prof. B V S Viswanadham, Department of Civil Engineering, IIT Bombay

Prof. B V S Viswanadham, Department of Civil Engineering, IIT Bombay 22 Module 5: Lecture -4 on Stability of Slopes Sudden drawdown Determination of most critical slip surface Criteria for most critical slip surface = Minimum factor of safety Trial and error approach involves

More information

Numerical Analysis of the Bearing Capacity of Strip Footing Adjacent to Slope

Numerical Analysis of the Bearing Capacity of Strip Footing Adjacent to Slope International Journal of Science and Engineering Investigations vol. 4, issue 46, November 25 ISSN: 225-8843 Numerical Analysis of the Bearing Capacity of Strip Footing Adjacent to Slope Mohammadreza Hamzehpour

More information

A Regional Research and Dissemination Programme. Phase III SOLAR BOX DRYER DESIGN, CONSTRUCTION AND OPERATION MANUAL

A Regional Research and Dissemination Programme. Phase III SOLAR BOX DRYER DESIGN, CONSTRUCTION AND OPERATION MANUAL RENEWABLE ENERGY TECHNOLOGIES IN ASIA: A Regional Research and Dissemination Programme Phase III SOLAR BOX DRYER DESIGN, CONSTRUCTION AND OPERATION MANUAL Energy Field of Study School of Environment, Resources

More information

6 BRIDGES. 6.1 Design philosophy. Proposed bridges

6 BRIDGES. 6.1 Design philosophy. Proposed bridges SECTION 6 BRIDGES 6 BRIDGES Throughout the Project, bridges are a key visual element and marker for road users, pedestrians and cyclists. The design of bridges, as with other visible structures, has been

More information

HEAT REMOVAL TESTS FOR THE HIGH PERFORMANCE VAULT STORAGE SYSTEM OF SPENT NUCLEAR FUEL

HEAT REMOVAL TESTS FOR THE HIGH PERFORMANCE VAULT STORAGE SYSTEM OF SPENT NUCLEAR FUEL HEAT REMOVAL TESTS FOR THE HIGH PERFORMANCE VAULT STORAGE SYSTEM OF SPENT NUCLEAR FUEL M. Oda*, M. Shimizu*, N. Kumagai*, H. Kanai**, M. Tanabe** *Nuclear Fuel Cycle Group, Power & Industrial Systems R&D

More information

Analysis of Embankments with Different Fill Materials using Plaxis-2D

Analysis of Embankments with Different Fill Materials using Plaxis-2D Analysis of Embankments with Different Fill Materials using Plaxis-2D A.Laxminarayana 1, M. Naresh 2 1 PG Student, Department of civil engineering, JNTUH, Hyderabad, Telangana, India 2 Assistant Professor,

More information

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater Gurpreet Singh and Satwant Singh Lala Lajpat Rai Institute of Engineering and Technology, Moga (Punjab) 142001 Abstract : Artificial

More information

Available online at ScienceDirect. Energy Procedia 91 (2016 ) 35 41

Available online at   ScienceDirect. Energy Procedia 91 (2016 ) 35 41 Available online at www.sciencedirect.com ScienceDirect Energy Procedia 91 (216 ) 35 41 SHC 215, International Conference on Solar Heating and Cooling for Buildings and Industry Butane heat pipes for stagnation

More information

Pleated blinds, free hanging units FS, FK, FE Description

Pleated blinds, free hanging units FS, FK, FE Description Pleated blinds, free hanging units FS, FK, FE 7 FS 6.2 6.1 5 1 12 2 3 FK 4 FE 8 10 11 9 13 Application Anti-glare protection and visual privacy as well as protection against summer heat. For installation

More information

A novel test method for predicting crushing elasticity in medium fluting with higher relevance than for instance currently used methods like CMT

A novel test method for predicting crushing elasticity in medium fluting with higher relevance than for instance currently used methods like CMT White paper Thomas Fürst (ABB) Lorentzen & Wettre products, Sweden Peter Gerards (Smurfit Kappa) Product Development, Netherlands A novel test method for predicting crushing elasticity in medium fluting

More information

NEWS 2017 SANIFLO. Pumps and pumping stations

NEWS 2017 SANIFLO. Pumps and pumping stations NEWS 2017 SANIFLO Pumps and pumping stations SFA, WORLD LEADER IN SANITARY FACILITIES MADE IN FRANCE For 60 years, the Société Française d Assainissement [French Sanitation Company] has worked on improving

More information

B.Tech. First Semester Examination Basics of Mechanical Engineering (ME-101F)

B.Tech. First Semester Examination Basics of Mechanical Engineering (ME-101F) B.Tech. First Semester Examination Basics of Mechanical Engineering (ME-101F) Q. 1. (a) Differentiate between water tube boiler and fire tube boiler. Ans. Comparison Between 'Fire-tube and Water tube'

More information

Load-Carrying Capacity of Stone Column Encased with Geotextile. Anil Kumar Sahu 1 and Ishan Shankar 2

Load-Carrying Capacity of Stone Column Encased with Geotextile. Anil Kumar Sahu 1 and Ishan Shankar 2 Load-Carrying Capacity of Stone Column Encased with Geotextile Anil Kumar Sahu 1 and Ishan Shankar 2 1 Professor, Department of Civil Engineering, Delhi Technological University, Delhi, India (sahuanilkr@yahoo.co.in)

More information

EXPERIMENT NO. III AIR ENTRAINMENT INTO AN IRS DEVICE

EXPERIMENT NO. III AIR ENTRAINMENT INTO AN IRS DEVICE Objective EXPERIMENT NO. III AIR ENTRAINMENT INTO AN IRS DEVICE To investigate air entrainment into a louvered infrared suppression (IRS) device experimentally on a laboratory scale set up both with cold

More information

AUTOMATIC FIRE EXTINGUISHING and VISUAL GUIDE SYSTEMS for TUNNEL PROTECTION

AUTOMATIC FIRE EXTINGUISHING and VISUAL GUIDE SYSTEMS for TUNNEL PROTECTION AUTOMATIC FIRE EXTINGUISHING and VISUAL GUIDE SYSTEMS for TUNNEL PROTECTION Generals Caccialanza & C. developed in the last years some technologically very innovative products, aimed to provide a very

More information

Footbridge 2005 Second International Conference

Footbridge 2005 Second International Conference CONCEPTUAL DESIGN OF THE NEW COIMBRA FOOTBRIDGE António ADÃO DA FONSECA Structural Engineer and Chairman of AFAssociados Consultores de Engenharia Professor at Faculty of Engineering - University of Porto,

More information

Developing Dam Operations & Maintenance Manuals

Developing Dam Operations & Maintenance Manuals Developing Dam Operations & Maintenance Manuals WEBINAR AGENDA Introduction General Information Operations Inspections Question & Answer Break Instrumentation & Monitoring Typical Maintenance Issues Question

More information

Experimental tests for geosynthetics anchorage trenches

Experimental tests for geosynthetics anchorage trenches Experimental tests for geosynthetics anchorage trenches Girard H. Cemagref, Bordeaux, France Briançon L Cnam, Paris, France Rey E. Cnam, Paris, France Keywords: geosynthetics, anchorage trench, full-scale

More information

Effect of Placement of Footing on Stability of Slope

Effect of Placement of Footing on Stability of Slope Scientific Journal of Impact Factor (SJIF) : 3.134 ISSN (Print) : 2348-6406 ISSN (Online): 2348-4470 International Journal of Advance Engineering and Research Development Effect of Placement of Footing

More information

Jurnal UMP Social Sciences and Technology Management Vol. 3, Issue. 3,2015

Jurnal UMP Social Sciences and Technology Management Vol. 3, Issue. 3,2015 The Design of a Heat Exchanger Shell - Tube as Evaporator an Absorption Chiller Cycle to Reduce the Temperature of the Air Entering Diesel Engine Heavy Loads 75% And 50% of the Engine Part Seyyede Sepideh

More information

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this lecture are to: 1. Importance of complete vapour compression refrigeration

More information

pump SMP60 Technical Data Sheet

pump SMP60 Technical Data Sheet DeLaval semisolid manure pump SMP60 Technical Data Sheet DeLaval semi-solid manure pump SMP60 Lockout valves Hopper Access port Inlet tube Bolted outlet Unique features found only on SMP60 Features Hopper

More information

AUDITORIUM OF THE MORGAN LIBRARY, COMPUTER AIDED DESIGN AND POST-CONSTRUCTION RESULTS

AUDITORIUM OF THE MORGAN LIBRARY, COMPUTER AIDED DESIGN AND POST-CONSTRUCTION RESULTS AUDITORIUM OF THE MORGAN LIBRARY, COMPUTER AIDED DESIGN AND POST-CONSTRUCTION RESULTS BFG Katz E Kahle LIMSI-CNRS, BP 133, 91403 Orsay, France, email brian.katz@limsi.fr Kahle Acoustics, 188 avenue Molière,

More information

Heat Transfer in Evacuated Tubular Solar Collectors

Heat Transfer in Evacuated Tubular Solar Collectors Heat Transfer in Evacuated Tubular Solar Collectors Graham L. Morrison, Indra Budihardjo and Masud Behnia School of Mechanical and Manufacturing Engineering University of New South Wales Sydney 2052 Australia

More information

2I-5 Bioswales (Numbering pending)

2I-5 Bioswales (Numbering pending) Iowa Stormwater Management Manual 2I-3 2I-5 Bioswales (Numbering pending) Source: Steve Anderson, 2011 BENEFITS Low =

More information

SUMMARIZED CURRICULUM VITAE

SUMMARIZED CURRICULUM VITAE SUMMARIZED CURRICULUM VITAE Dr. Omer Bilhan Dr. Omer Bilhan Assistant Professor and Chair Name: Omer Surname: BILHAN Address : Nevsehir HBV University Department of Civil, 50300, Nevsehir / Turkey, Wayne

More information

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection RESEARCH ARTICLE OPEN ACCESS Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection Tanuj Kumar Sahu 1, Vishal Gupta 2, Ajay Kumar Singh 3

More information

BRINE CIRCULATED ICE THERMAL STORAGE SYSTEM DESIGN - CASE ILLUSTRATION - Partial Ice Storage for Air Conditioning Application

BRINE CIRCULATED ICE THERMAL STORAGE SYSTEM DESIGN - CASE ILLUSTRATION - Partial Ice Storage for Air Conditioning Application 1 BRINE CIRCULATED ICE THERMAL STORAGE SYSTEM DESIGN - CASE ILLUSTRATION - Partial Ice Storage for Air Conditioning Application By: T. S. Wan Date: Oct. 7, 1995 Copy Right 1995 by T. S. Wan All rights

More information

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING H. Kotani, R. Satoh, T. Yamanaka Dept. of Architectural Engineering, School of Engineering, Osaka University, Osaka, Japan ABSTRACT The purpose

More information

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack #1 Digvijay A. Shelar, #2 N.S. Gohel, #3 R. S. Jha #1 Mechanical Engineering Department,

More information

Incorporating Aluminum Honeycomb to Increase Efficiency of U-tube Removable Heat Exchanger

Incorporating Aluminum Honeycomb to Increase Efficiency of U-tube Removable Heat Exchanger Incorporating Aluminum Honeycomb to Increase Efficiency of U-tube Removable Heat Exchanger Daniel Soto 1 and Daniel Corona 2 California Polytechnic State University, San Luis Obispo, San Luis Obispo, California,

More information

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2 Modern Applied Science; Vol. 9, No. 13; 2015 ISSN 1913-1844 E-ISSN 1913-1852 Published by Canadian Center of Science and Education The Design of a Shell-Tube Heat Exchanger as Evaporator an Absorption

More information

Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions

Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions Joint 18th IHPC and 12th IHPS, Jeju, Korea, June 12-16, 2016 Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions Jens Weyant

More information

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE. DFE T ECHNOLOGY As components become smaller, component mixes become more diverse, and board densities continue to increase, the processes of packaging, interconnection, and assembly are challenging the

More information

Bearing Capacity Theory. Bearing Capacity

Bearing Capacity Theory. Bearing Capacity Bearing Capacity Theory Bearing Capacity 1 Bearing Capacity Failure a) General Shear Failure Most common type of shear failure; occurs in strong soils and rocks b) Local Shear Failure Intermediate between

More information

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way 1 CHAPTER I INTRODUCTION In the modern life, electronic equipments have made their way in to practically every part, which is from electronic gadgets to high power computers. Electronic components have

More information

Operator s Manual. Linear Asphalt Compactor. Jesse D. Doyle Isaac L. Howard, PhD Mississippi State University. January 2010 CMRC M 10-1 Version 1

Operator s Manual. Linear Asphalt Compactor. Jesse D. Doyle Isaac L. Howard, PhD Mississippi State University. January 2010 CMRC M 10-1 Version 1 Operator s Manual Linear Asphalt Compactor Mississippi Department of Transportation Jesse D. Doyle Isaac L. Howard, PhD Mississippi State University An Industry, Agency & University Partnership January

More information

Lecture 18 Auditorium Acoustics

Lecture 18 Auditorium Acoustics Audio System Engineering Prof. Shyamal Kumar Das Mandal Department of Electronics and Communication Engineering Indian Institute of Technology, Kharagpur Lecture 18 Auditorium Acoustics So, let us start.

More information

Chapters 6 and 8 revised May 2013

Chapters 6 and 8 revised May 2013 A cooperative effort between the North Carolina Sedimentation Control Commission, the North Carolina Department of Environment and Natural Resources, and the North Carolina Agricultural Extension Service.

More information

BY-LAW CONCERNING THE DESIGNATION OF HABITAT 67, BEARING NUMBER 2600, AVENUE PIERRE-DUPUY, AS A HISTORIC MONUMENT

BY-LAW CONCERNING THE DESIGNATION OF HABITAT 67, BEARING NUMBER 2600, AVENUE PIERRE-DUPUY, AS A HISTORIC MONUMENT VILLE DE MONTRÉAL BY-LAW 07-037 BY-LAW CONCERNING THE DESIGNATION OF HABITAT 67, BEARING NUMBER 2600, AVENUE PIERRE-DUPUY, AS A HISTORIC MONUMENT In view of sections 70 to 83 of the Cultural Property Act

More information

Tel Group

Tel Group www.wamechsi.com Tel +27 12 808 0682 sales@wamechsi.com VERTICAL SHAFT, LOW SPEED, AERATORS Technical Specifications Vertical shaft, low speed aerators are ideal for the bacterial oxidization of effluent

More information

DESIGN, FABRICATION & PERFORMANCE ANALYSIS OF SOLAR AIR HEATER

DESIGN, FABRICATION & PERFORMANCE ANALYSIS OF SOLAR AIR HEATER DESIGN, FABRICATION & PERFORMANCE ANALYSIS OF SOLAR AIR HEATER Amrita Agrawal 1, Nalin Deshpande 2, Aakanksha Dubey 3 Department of Energy Maulana Azad National Institute of Technology (MANIT), Bhopal

More information

DEVELOPMENT OF SUCTION SCOOPS FOR MIDAMERICAN ENERGY COMPANY S GEORGE NEAL NORTH CIRCULATING WATER PUMP INTAKE STRUCTURES

DEVELOPMENT OF SUCTION SCOOPS FOR MIDAMERICAN ENERGY COMPANY S GEORGE NEAL NORTH CIRCULATING WATER PUMP INTAKE STRUCTURES DEVELOPMENT OF SUCTION SCOOPS FOR MIDAMERICAN ENERGY COMPANY S GEORGE NEAL NORTH CIRCULATING WATER PUMP INTAKE STRUCTURES by Tatsuaki Nakato Sponsored by Burns & McDonnell 9400 Ward Parkway Kansas City,

More information

Moisture Content Effect on Sliding Shear Test Parameters in Woven Geotextile Reinforced Pilani Soil

Moisture Content Effect on Sliding Shear Test Parameters in Woven Geotextile Reinforced Pilani Soil International Journal of Engineering Science Invention ISSN (Online): 2319 6734, ISSN (Print): 2319 6726 Volume 2 Issue 8 ǁ August 2013 ǁ PP.10-15 Moisture Content Effect on Sliding Shear Test Parameters

More information

A PVC geomembrane integrated in the landscape

A PVC geomembrane integrated in the landscape 34. Dresdner Wasserbaukolloquium 2011: Wasserkraft mehr Wirkungsgrad + mehr Ökologie = mehr Zukunft Dresdner Wasserbauliche Mitteilungen 105 A PVC geomembrane integrated in the landscape Dr. Alberto SCUERO

More information

DESIGN AND ANALYSIS OF PIPE HEAT EXANGERS WITH INSIDE FINS

DESIGN AND ANALYSIS OF PIPE HEAT EXANGERS WITH INSIDE FINS DESIGN AND ANALYSIS OF PIPE HEAT EXANGERS WITH INSIDE FINS Helan Jacob.J 1,Chandra Mohan.B 2,Palanisamy.S 3 1, P.G. Scholars, Department ofthermal Engineering, Oxford Engineering college,pratiyur, Trichy.

More information

3D-Evaluation Method for Descaling Capability of Hot Strip Mill

3D-Evaluation Method for Descaling Capability of Hot Strip Mill 82 China Steel Technical Report, No. 24, 3D-Evaluation pp. 83-87, (2011) Method for Descaling Capability of Hot Strip Mill 3D-Evaluation Method for Descaling Capability of Hot Strip Mill CHUN-CHAO SHIH*,

More information

Performance Analysis Of Double Inclination Ribbed Solar Air Heater Rectangular Duct By Liquid Crystal Thermography

Performance Analysis Of Double Inclination Ribbed Solar Air Heater Rectangular Duct By Liquid Crystal Thermography Performance Analysis Of Double Inclination Ribbed Solar Air Heater Rectangular Duct By Liquid Crystal Thermography Amit Kumar Gautam¹, Dr. J. L. Bhagoria² ¹M.Tech. Scholar, Mechanical Engineering, ²Professor,

More information

Hydraulic analysis marks start of rebuilding after bridge collapse

Hydraulic analysis marks start of rebuilding after bridge collapse Hydraulic analysis marks start of rebuilding after bridge collapse By Tawny Quast The remains of the I-35W Bridge shortly after the collapse. On August 1, 2007, the I-35W bridge over the Mississippi River

More information

5. LOW IMPACT DEVELOPMENT DESIGN STANDARDS

5. LOW IMPACT DEVELOPMENT DESIGN STANDARDS 5. LOW IMPACT DEVELOPMENT DESIGN STANDARDS Low Impact Development (LID) requires a shift in stormwater management away from conveying runoff to a small number of downstream points through hydraulically

More information

Severn River Sub-Watershed: BMP 09-Retrofit

Severn River Sub-Watershed: BMP 09-Retrofit Project ID: BMP_09 Total Treated Drainage Area: 4.57 acres Total Treated Impervious Area: 2.9 acres Total Water Quality Volume (WQv): ~10,300 cubic feet; 0.236 acre-foot Rainfall Depth Treated (Pe): 1

More information

EFFECT OF CENTRAL PILE IN INCREASING THE BEARING CAPACITY OF BORED PILE GROUPS

EFFECT OF CENTRAL PILE IN INCREASING THE BEARING CAPACITY OF BORED PILE GROUPS EFFECT OF CENTRAL PILE IN INCREASING THE BEARING CAPACITY OF BORED PILE GROUPS Mohamed M. Shahin Department of Civil Engineering, 7 th October University, Misurata,, Libya, E-mail: Mohamed_zubi@yahoo.com

More information

J. LINES, Graham Corp., Batavia, New York

J. LINES, Graham Corp., Batavia, New York Originally appeared in: January 2017, pgs 77-81. Used with permission. Process Engineering J. LINES, Graham Corp., Batavia, New York Key design considerations for vacuum process condensers The crude oil

More information

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling Enhancement using Herringbone wavy & Smooth Wavy fin Exchanger for Hydraulic Oil Cooling 1 Mr. Ketan C. Prasadi, 2 Prof. A.M. Patil 1 M.E. Student, P.V.P.I.T.,Budhagaon,Sangli AP-India 2 Associate Professor,

More information

In the name of God. Jami Institute of Jami - Mehdi Rasti

In the name of God. Jami Institute of Jami - Mehdi Rasti In the name of God 1 Heat Transfer Jami Institute of Technology Heat Exchangers part 2 Mehdi Rasti 2 The Counter-Flow Heat Exchanger In contrast to the parallel-flow exchanger, this configuration provides

More information

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System Kwanghee Seo 1) and Taewan Kim 2)* 1) KEPCO Engineering & Construction Company. INC., 269 Hyeoksin-ro,

More information

PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE

PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE Ram Mohan Gupta 1, Dr. Shatyendra Singh 2 Mr. Simant Srivastava 3 1 Mechanical Engineering, Uttarakhand

More information

Influence of the magnitude of the angle of attack on the voltage produced by a miniature wind turbine

Influence of the magnitude of the angle of attack on the voltage produced by a miniature wind turbine World Transactions on Engineering and Technology Education Vol.9, No.3, 2011 2011 WIETE Influence of the magnitude of the angle of attack on the voltage produced by a miniature wind turbine Josué Njock

More information

Morgan s Subdivision Historic District Character-defining Features

Morgan s Subdivision Historic District Character-defining Features Morgan s Subdivision Historic District Character-defining Features DISTRICT DESCRIPTION This small addition, designed as a neighborhood for those wishing to move east from Capitol Hill, was predominantly

More information

STUDY ON TEMPERATURE, RH AND AIR FLOW VELOCITY DISTRIBUTION INSIDE THE GREENHOUSE EFFECT SOLAR DRYER

STUDY ON TEMPERATURE, RH AND AIR FLOW VELOCITY DISTRIBUTION INSIDE THE GREENHOUSE EFFECT SOLAR DRYER STUDY ON TEMPERATURE, RH AND AIR FLOW VELOCITY DISTRIBUTION INSIDE THE GREENHOUSE EFFECT SOLAR DRYER WULANDANI, D., K. ABDULLAH, E. HARTULISTIYOSO Department of Agricultural Engineering, Faculty of Agricultural

More information

Design Optimization of Variable Geometry Microchannel Heat Exchangers

Design Optimization of Variable Geometry Microchannel Heat Exchangers Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Design Optimization of Variable Geometry Microchannel Heat Exchangers Long

More information

CCD and CID solid-state detectors

CCD and CID solid-state detectors CCD and CID solid-state detectors Technical Overview 5110 ICP-OES Introduction Many of today s ICP-OES instruments have progressed from traditional photomultiplier tube (PMT) detection systems to solid-state

More information

The use of low head weirs to. perennial streams with their floodplains:

The use of low head weirs to. perennial streams with their floodplains: The use of low head weirs to reconnect severely entrenched perennial streams with their floodplains: An Anne Arundel County TMDL Watershed Implementation Plan Strategy presented by Hala Flores, P.E Mid

More information

A. Regional Detention Requirements

A. Regional Detention Requirements I. GENERAL DESIGN GUIDELINES A. Full-spectrum detention is provided for all new development, redevelopment or expansion of a site to provide for water quality and flood control detention. B. Detention

More information

Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink

Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink 1 Asoka R.G, 2 Aishwarya N, 3 Rajasekar S and 4 Meyyappan N 1234 Department of Chemical Engineering Sri Venkateswara College of Engineering,

More information

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1 HEFAT27 5 th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp PERFORMANCE ANALYSIS OF AIR-COOLED CONDENSER USING MICRO-FIN TUBES P.A.Patil

More information

High Efficiency Heat Pump for Domestic Hot Water Generation

High Efficiency Heat Pump for Domestic Hot Water Generation Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 28 High Efficiency Heat Pump for Domestic Hot Water Generation Georges Nehm

More information

EXPERIMENTAL PERFORMANCE ANALYSIS OF SOLAR AIR HEATER WITH THREE DIFFERENT MODIFICATIONS IN ABSORBER PLATE

EXPERIMENTAL PERFORMANCE ANALYSIS OF SOLAR AIR HEATER WITH THREE DIFFERENT MODIFICATIONS IN ABSORBER PLATE EXPERIMENTAL PERFORMANCE ANALYSIS OF SOLAR AIR HEATER WITH THREE DIFFERENT MODIFICATIONS IN ABSORBER PLATE ABSTRACT: 1 Chandan Kumar, 2 Hari Singh 1,2 Mechanical Engineering dept, Gyan Vihar University,

More information

Performance of an Improved Household Refrigerator/Freezer

Performance of an Improved Household Refrigerator/Freezer Performance of an Improved Household Refrigerator/Freezer D. O. Ariyo Department of Mechanical Engineering, School of Engineering, Federal Polytechnic, Offa, Nigeria Y. L. Shuaib-Babata Department of Mechanical

More information

Reinforced FBG Sensors Serve Demanding Applications

Reinforced FBG Sensors Serve Demanding Applications Reinforced FBG Sensors Serve Demanding Applications Kevin Hsu, Andrei Csipkes, and Tommy Jin Technica Optical Components / 3657 Peachtree Rd, Suite 10A, Atlanta, 30319, USA, info@technicasa.com, www.technicasa.com

More information

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) www.blowtech.in we make air move Blowtech Air Devices Pvt. Ltd. was founded in 1988 and quickly established

More information

AN ASSESSMENT OF STRENGHT PROPERTIES OF. Diti Hengchaovanich and Nimal S. Nilaweera 1

AN ASSESSMENT OF STRENGHT PROPERTIES OF. Diti Hengchaovanich and Nimal S. Nilaweera 1 ANASSESSMENTOFSTRENGHTPROPERTIESOF VETIVERGRASSROOTSINRELATIONTOSLOPE STABILIZATION DitiHengchaovanichandNimalS.Nilaweera 1 Introduction Vetivergrass(Vetiveriazizanioides)hasbeenutilizedto reducesoilerosioninmanycountriesthroughouttheworldfora

More information

A DETAILED ANALYSIS OF SLOPE STABILITY USING FINITE ELEMENT METHOD (FEM)

A DETAILED ANALYSIS OF SLOPE STABILITY USING FINITE ELEMENT METHOD (FEM) A DETAILED ANALYSIS OF SLOPE STABILITY USING FINITE ELEMENT METHOD (FEM) S. Halder 1*, M. O. Imam 2 & M. S. Basir 1 1 Department of Civil & Water Resources Engineering, Chittagong University of Engineering

More information

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length HEIMO WALTER Institute for Thermodynamics and Energy Conversion Vienna University

More information

Available online at ScienceDirect. Procedia Engineering 125 (2015 )

Available online at  ScienceDirect. Procedia Engineering 125 (2015 ) Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 125 (2015 ) 331 337 The 5th International Conference of Euro Asia Civil Engineering Forum (EACEF-5) Effect of Area Development

More information

However, uncertainty exists on the proper approaches to fastening claddings over exterior insulation.

However, uncertainty exists on the proper approaches to fastening claddings over exterior insulation. NOTE: As of January 1, 2018 ROXUL is doing business as ROCKWOOL. As of April 1, 2016 COMFORTBOARD CIS is now COMFORTBOARD 110. These are solely name changes. There have been no changes or alterations to

More information

A Novel Approach for the Thermal Management. of PC Power Supply

A Novel Approach for the Thermal Management. of PC Power Supply ISTP-16, 005, PRAGUE 16 TH INTERNATIONAL SYMPOSIUM ON TRANSPORT PHENOMENA A Novel Approach for the Thermal Management of PC Power Supply Fu-Sheng Chuang*, Sheam-Chyun Lin, Jon-Ting Kuo, Chien-An Chou Department

More information

EQUIPMENT FOR OIL/PAPER DRYING AND STABILIZATION

EQUIPMENT FOR OIL/PAPER DRYING AND STABILIZATION EQUIPMENT FOR OIL/PAPER DRYING AND STABILIZATION At a glance: EQUIPMENT FOR OIL/PAPER DRYING AND STABILIZATION HEDRICH offers a variety of drying technologies for different applications. Only carefully

More information

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM Sachin Kumar 1, Vicky Ranga 2 1Assistant Professor, Department of Mechanical Engineering, Jagan Nath University Jhajjar, Haryana, India. 2Scholar.

More information

Krantz. HVAC systems for hospitals. System solutions

Krantz. HVAC systems for hospitals. System solutions Krantz HVAC systems for hospitals System solutions Best air management solutions through customized systems Krantz has been a leading specialist in comprehensive HVAC system solutions for more than 40

More information

EFFECT OF RELICT JOINTS IN RAIN INDUCED SLOPE FAILURES IN RESIDUAL SOIL

EFFECT OF RELICT JOINTS IN RAIN INDUCED SLOPE FAILURES IN RESIDUAL SOIL EFFECT OF RELICT JOINTS IN RAIN INDUCED SLOPE FAILURES IN RESIDUAL SOIL Neethimappiriya Tharmalingam, Student (Email: neethi_26@yahoo.com) N.W.H. Lakshamana, Student (Email: hansaka8888@yahoo.com) R.D.T.B.

More information

Bioretention cell schematic key

Bioretention cell schematic key Bioretention Cells Bioretention cell schematic key 1 3 Hardwood mulch 2 Curb cut 3 18-30 Modified soil 4 Stone aggregate choker layer 5 Stone aggregate base layer 6 Subdrain 7 Undisturbed soil 8 Overflow/Cleanout

More information

Subject Name: RESERVOIR AND FARM POND DESIGN (2+1) CONTENTS

Subject Name: RESERVOIR AND FARM POND DESIGN (2+1) CONTENTS Subject Name: RESERVOIR AND FARM POND DESIGN (2+1) CONTENTS (Name of Course Developer: Prof. B. C. Sahoo and Prof. S. N. Panda, AgFE Department, IIT Kharagpur, Kharagpur 721 302) Module 1: Fundamentals

More information

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 11 April 2015 ISSN (online): 2349-6010 CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

More information

A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS

A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS V. BHOGESWARA RAO Research Scholar Email:pallivayala@gmail.com Dr. S. CHAKRADHAR GOUD Principal, Sri Sarada Institute of Science and Technology

More information

ICSV14. Cairns Australia 9-12 July, Noise reduction of handheld vacuum cleaners according to geometric optimization of air passages

ICSV14. Cairns Australia 9-12 July, Noise reduction of handheld vacuum cleaners according to geometric optimization of air passages ICSV14 Cairns Australia 9-12 July, 2007 Noise reduction of handheld vacuum cleaners according to geometric optimization of air passages M.J. Mahjoob and H.Ashrafi Noise, Vibration, Acoustics (NVA) research

More information

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION - 165 - CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION Wojciech Węgrzyński, Grzegorz Krajewski, Paweł Sulik Fire Research Department, Building Research Institute (ITB), Poland ABSTRACT

More information

High-efficiency Turbo Chiller (NART Series)

High-efficiency Turbo Chiller (NART Series) 67 High-efficiency Turbo Chiller (NART Series) Wataru Seki* 1 Kenji Ueda* 1 Jyou Masutani* 2 Yoichirou Iritani* 2 Turbo chillers are widely used for district heating and cooling, heat storage (regeneration)

More information

Investigating the Effects of Sprinkler Sprays on Fire-Induced Doorway Flows: A Two-Part Study. Jeremiah Crocker and Dr. Bin Xiao New Technology Team

Investigating the Effects of Sprinkler Sprays on Fire-Induced Doorway Flows: A Two-Part Study. Jeremiah Crocker and Dr. Bin Xiao New Technology Team Jeremiah Crocker and Dr. Bin Xiao New Technology Team Copyright 2010 Tyco Fire Suppression & Building Products. All rights reserved. The products and specifications published herein are for general evaluation

More information