S3 standard control panel
|
|
- Christopher Dean
- 5 years ago
- Views:
Transcription
1 S3 standard control panel Package MD4 English 23/01/06 Installation instructions Technical instructions
2 Contents Symbols used Important recommendations Description Presentation Commissionning Mounting - Connections Control panel assembly Electrical connections Access to the connection terminal Electricity supply - Flow controller Connecting the burner Connecting the safety thermostat alarm report Connecting the flue gas thermometer (Package BP28) Skeleton Diagrams Spare parts Control panel S3 23/01/ A
3 Symbols used Caution danger Risk of injury and damage to equipment. Attention must be paid to the warnings on safety of persons and equipment Specific information Information must be kept in mind to maintain comfort Reference Refer to another manual or other pages in this instruction manual DHW: Domestic hot water Switch off the power supply before doing the work!. This appliance must be connected to the earth. Important recommendations For a proper operating of the boiler, follow carefully the instructions. Any intervention on the appliance and heating equipment must be carried out by a qualified technician. The manufacturer is not liable for any improper use of the appliance or failure to maintain or install the unit correctly (the user shall take care to ensure that the system is installed by a qualified fitter). Keep to the polarity shown on the terminals : phase (L), neutral (N) and earth. 23/01/ A Control panel S3 3
4 Description 1 Introduction Standard electromechanical control panel for heating installations without a control unit or for those which include a boiler room control cabinet. The control panel is used to control boilers with 1 or 2-stage burners. The control panel S3 equips the boilers GT 330. optional: Flue gas thermometer (Package BP28) 2 Presentation Control panel S3 includes: - 2 Boiler thermostats - 1 Safety thermostat The boiler thermostat regulates the boiler operating temperature. The safety thermostat with manual reset ensures that the boiler operates safely. In the event that there is an abnormal rise in the temperature in the boiler 110 C. Advise your installation engineer. 3 Operating principle The boiler may be regulated: - either by the boiler thermostats If the boiler is fitted with a 2-stage burner, each thermostat is assigned to the operation of one stage. The 2nd stage thermostat must be set to a value at least 5 C lower than the 1st stage thermostat. - or by a control unit located in a cabinet Operating security is provided by the safety thermostat with manual reset. 4 Technical characteristics Compliance / Stamp This product complies to the requirements to the European Directives and following standards: - 73/23/EEC Low Voltage Directive Reference Standard : EN /336/EEC Electromagnetic Compatibility Directive Generic standards : EN ; EN Control panel S3 23/01/ A
5 Presentation 1. General ON (1) / OFF (0) switch 2. Switch Test-STB Temporary action to test the safety thermostat 3. Boiler thermostats (30 to 85 C) A factory-set stop limits the maximum temperature to 75 C. The stop may be moved if necessary (See Moving the thermostat stop). 4. Boiler thermometer 5. Location for flue gas thermometer (optional) 6. Timed circuit breaker (10 A) with delayed action and manual reset 7. Safety thermostat with manual reset (set to 110 C) 23/01/ A Control panel S3 5
6 Commissionning The first start-up is to be performed by your installation engineer. Before starting the boiler, check if the installation is filled with water. Start the boiler in the following order : Boiler temperature regulation by means of the thermostats Set the boiler thermostats 3 to the desired position. The 2nd stage thermostat must be set to a value at least 5 C lower than the 1st stage thermostat. If there is no control unit, we advise you never to set the boiler thermostat below mark 4 (approx. 40 C) in order to avoid the risk of combustion products condensing on the walls of the boiler. If necessary, change the position of the maximim temperature. Moving the thermostat stop Set the On/Off switch to 1. A factory-set stop limits the maximum temperature to 75 C. To move the stop, proceed as follows: Pull the thermostat button out carefully (use pliers and a cloth). Remove the stop with the pliers. Put the stop in the hole of the desired higher temperature (maximum 85 C). Control unit in boiler room electrical cabinet See the instructions supplied with the control unit and any remote control unit used. Check that safety thermostat 7 is properly set. To do so, Unscrew the safety thermostat cover and press the reset button using a screwdriver. 6 Control panel S3 23/01/ A
7 Mounting - Connections 1 Control panel assembly Refer to the technical and assembly instructions delivered with the boiler. 2 Electrical connections Only qualified professionnals may carry out electrical connections, always with the power off. As the electrical wiring has been carefuly checked in the factory, the internal connections on the control panel must not be changed in any way. Electrical connections must match the electrical diagrams delivered with the equipment and comply with the instructions in the manual. The equipment must have a power supply equipped with a omnipolar switch with an opening distance above 3 mm. The earth must comply with the NFC (France) or the RGPT (Belgium) standards. 3 Access to the connection terminal All connections are made with the terminal boxes designed for that purpose on the back of the boiler's command board. Bring the connecting cables to the control panel through the openings located on the rear panel of the boiler and 1 or 2 cable channels, depending upon the type of boiler. Attach the cables to the cable clamps provided for this purpose. Keep to the polarity shown on the terminals : phase (L), neutral (N) and earth. 23/01/ A Control panel S3 7
8 4 Electricity supply - Flow controller Make the electrical connection to the terminals 1, 2, 3. Connection to the mains is done using a 3-wire cable with a cross section of 0.75 mm² on the terminal block (terminals 1, 2, 3). For other electrical connections, use the 3 wire cable with a diameter of 0.75 mm². The flow controller contact is connected to the safety circuit in series (between terminal 5 on the terminal block and terminal L1 on the burner, for example). 8 Control panel S3 23/01/ A
9 5 Connecting the burner Burner cable Burner side 7-pin plug for 1-stage burners or stage 1 of 2-stage burners 4-pin plug for stage 2 of the burner Connector block with connection pins to the control panel terminal block The control panel is supplied with the burner power cable. One end of this cable is fitted with two European 7 and 4 pin sockets and the other with a terminal with male connecting pins. Control panel Burner fitted with pin connectors Refer to the burner cable diagram. Burner without plug-in connectors In this case, the connectors supplied with the burner cable must be rewired. The diagram shows the wire numbers and the terminals of the burner connectors. Connect the terminal block to terminals 4 to 12 on the fixed terminal block on the control panel using the male pins. 23/01/ A Control panel S3 9
10 The table below specifies the way in which the cables are to be connected on the burner control box. Connector terminal -No Wire No From Connection to the burner control box L1 7 Continuous phase from the safety thermostat Burner main supply V/J Earth connection Earth connection N 6 Neutral taken after On/Off Neutral terminal T1/T2 5/4 Dry contact of the stage 1 boiler thermostat Insert in the control circuit of boiler stage 1 S3 8 Burner alarm indicator Alarm output (phase) T6 1 Stage 2 boiler thermostat input Insert in the control circuit of burner stage 2 T7 3 Stage 2 boiler off thermostat output Connect only if the burner is of the modulating type T8 2 Stage 2 boiler on thermostat output Insert in the control circuit of burner stage 2 If the electrical characteristics of the burner exceed the following values - inrush current > 16 A or - P > 450 W or - I > 2 A cos ϕ = 0.7 The burner controls must be relayed, e.g. with the relaying kit (package BP 51, optional). 7-pin plugs for connecting to the control panel and burner connectors. 10 Control panel S3 23/01/ A
11 6 Connecting the safety thermostat alarm report The insulated pin on the safety thermostat is used to connect an alarm report (thermostat with reversal contact). If the safety thermostat trips, a 230 V signal is present on this terminal. Open the control panel (3 screws at the back) to access the back of the safety thermostat. 23/01/ A Control panel S3 11
12 7 Connecting the flue gas thermometer (Package BP28) An optional flue gas thermometer may be fitted on the front of the control panel. To do so: - Cut the cover off with a cutter along the edges of the coloured rectangle - Clip the thermometer into the opening - Bring the sensor to the back of the boiler via the cable channel and insert it in the flue gas pipe. 12 Control panel S3 23/01/ A
13 Skeleton Diagrams BA Ç DJ10A L N TCH1 TCH2 TS1 TS2 VA ZB ZTB SCHEMA DE PRINCIPE - STROMLAUFPLAN - WIRING DIAGRAM - PRINCIPESCHEMA GT 330 STANDARD L BA 1a ZB 1 DJ10A 1 1a 1a TCH1 ZTB TCH2 TS1 θ TS2 θ BA 9 BA 10 BA 11 BA 12 BA 7 BA 8 BA 6 BA 5 L1 T1 T2 T6 T7 T8 Ê N S3 VA 1b 1a N BA ZB 2a BA 4 BARRETTE ANSCHLUSSLEISTE BA CONNECTING BOARD AANSLUITINGSKLEMMEN TERRE SCHUTZLEITER Ç EARTH AARDING DISJONCTEUR LEISTUNGSSCHALTER DJ10A CIRCUIT BREAKER THERMISCHE BEVEILIGING PHASE PHASE L PHASE FASE NEUTRE NULLEITER N NEUTRAL NULLEIDER THERMOSTAT DE CHAUDIERE 1ere ALLURE KESSEL TEMPERATURREGLER 1.STUFE TCH1 BOILER THERMOSTAT 1st STAGE KETELTHERMOSTAAT 1st TRAP THERMOSTAT DE CHAUDIERE 2eme ALLURE KESSEL TEMPERATURREGLER 2.STUFE TCH2 BOILER THERMOSTAT 2nd STAGE KETELTHERMOSTAAT 2de TRAP THERMOSTAT DE SECURITE SICHERHEITSTEMPERATURBEGRENZER TS1 HIGH LIMIT THERMOSTAT VEILIGHEIDSTHERMOSTAAT THERMOSTAT DE SECURITE CONDENSEUR BRENNWERTTAUSCHER STW TS2 CONDENSER THERMOSTAT VEILIG HEIDS THERMOSTAAT VOYANT ALARME ALARMLEUCHTE VA ALARM INDICATOR ALARM LAMPJE INTERRUPTEUR BRULEUR BRENNER SCHALTER ZB BURNER SWITCH BRANDER SCHAKELAAR INTERRUPTEUR TEST STB TEST STB SCHALTER ZTB TEST STB SWITCH TEST STB SCHAKELAAR N : A θ θ 23/01/ A Control panel S3 13
14 Spare parts To order a spare part, quote the reference number next to the part required. Control panel S3 for GT /01/ A DE DIETRICH THERMIQUE S.A.S. - Spare parts centre 4 rue d Oberbronn - F REICHSHOFFEN (0) (0) cpr dedietrichthermique.com
15 Rep Code no. Description Standard complete control panel Painted control panel base Cover Side plate Plastic coated panel Green S/S bipolar switch Thermometer Bipolar switch C safety thermostat to 90 C setting thermostat Setting button + Pin Timed circuit breaker (10 A) Standard beam Electric circuit pin plug pin plug Contact spring for pocket Spring for pocket 23/01/ A Control panel S3 15
16 FR DE DIETRICH THERMIQUE S.A.S. Direction des Ventes France 57, rue de la Gare F MERTZWILLER +33 (0) (0) AT DE DIETRICH HEIZTECHNIK Am Concorde Park 1 - B 4 / 28 A-2320 SCHWECHAT / WIEN +43 (0)1 / (0)1 / office@dedietrich.at In the interest of customers, De Dietrich Thermique SAS are continuously endeavouring to make improvements in product quality. All the specifications stated in this document are therefore subject to change without notice DE BE CH DE DIETRICH HEIZTECHNIK Rheiner Strasse 151 D EMSDETTEN +49 (0)25 72 / (0)25 72 / info@dedietrich.de VAN MARCKE Weggevoerdenlaan 5 B KORTRIJK +32 (0)56/ VESCAL S.A. / Z.I de la Veyre, St-Légier 1800 VEVEY (0) (0) LU RU CN NEUBERG S.A rue Jacques Stas L LUXEMBOURG +352 (0) DE DIETRICH 8 Gilyarovskogo Str. 7 R MOSCOW dedietrich@nnt.ru DE DIETRICH Room 512, Tower A, Kelun Building 12A Guanghua Rd, Chaoyang District C BEIJING +86 (0) (0) (0) (0) contactbj@dedietrich.com.cn AD001Z DE DIETRICH THERMIQUE 57, rue de la Gare F MERTZWILLER - BP 30
Control panel K3. Package MD2. Technical instructions. Installation instructions. English 08/02/06
Control panel K3 Package MD English 08/0/06 Installation instructions Technical instructions Contents Symbols used................................................................................3 Important
More informationControl panel B/B2. Package FM126 - Control panel B Package FM159 - Control panel B2. Technical instructions. Installation instructions
Control panel B/B2 Package FM126 - Control panel B Package FM159 - Control panel B2 English 17/01/06 Installation instructions Technical instructions Contents Symbols used................................................................................3
More informationControl panel (MD3) to be placed on the boiler (MD140) lateral control panel
GT 330 - GT 430 - GT 530 - GTU C 330 Control panel B3 EN Control panel (MD3) to be placed on the boiler (MD140) lateral control panel Installation and Service Manual 300008923-001-C . Contents 1 Symbols
More informationRange GT GTU C GT 220
Range GT 120 - GTU C 120 - GT 220 Low temperature fuel oil boiler Oil-fired condensation boiler English 21/09/06 Instructions for use Contents Important recommendations...................................................................3
More informationControl panel. Package RC 6. Installation and Service Manual A
EN Control panel Package RC 6 Installation and Service Manual 3000303-00-A Contents Introduction.............................................................................3. Symbols and abbreviations................................................................................3.
More informationDTG X.. N. Low temperature gas furnace. Instructions for use. English 14/11/2005
DTG X.. N Low temperature gas furnace English 14/11/2005 Instructions for use Contents Important recommendations...................................................................3 1 Aeration.................................................................................................3
More informationPackage FT 74. X control panel. Installation and Service Manual
en Package FT 74 X control panel Installation and Service Manual 7647029-03 . Contents 1 Safety instructions.......................................................................3 1.1 Important recommendations................................................................................3
More informationB 150p to B 500p. Independent domestic hot water tanks. Installation instructions. Instructions for use. Technical instructions.
B 150p to B 500p Independent domestic hot water tanks English 25/04/06 Installation instructions Instructions for use Technical instructions 94870007 Contents Introduction.................................................................................3
More informationWall-hung gas boilers. Instructions for use. English 31/08/05
City 1.24/II Chimney and VMC - City 1.24/II FF City 2.24/II Chimney and VMC - City 2.24/II FF - City 2.28 FF City 3.24/II Chimney - City 3.24/II FF City 24 BIC/II - City 24 BIC/II FF City Condens 1.24,
More informationControl panel B - FM126 B2 - FM159. Installation and Service Manual
en Control panel B - FM126 B2 - FM159 Installation and Service Manual 300002725-02 Contents 1 Symbols used...........................................................................3 2 Important recommendations...............................................................3
More informationC 310 ECO - C 610 ECO
EN Gas fired condensing boiler C 310 ECO - C 610 ECO User Guide 300015183-001-A Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3
More informationDIEMATIC 3 - FM129 DIEMATIC 3 CH - FM133
GT 0 - GTUC 0 - GT 0 - GTUC 0 en Control panel DIEMATIC 3 - FM9 DIEMATIC 3 CH - FM33 Installation instructions 300003765-0 Contents Symbols used...........................................................................3
More informationTRIO DT 350/3 DIETRISOL. Solar domestic hot water tanks. Installation instructions. Instructions for use. Technical instructions.
DIETRISOL TRIO DT 350/3 Solar domestic hot water tanks English 07/11/06 Installation instructions Instructions for use 8980N146A Technical instructions Contents Introduction.................................................................................3
More informationWHE 2.24 / WHE 2.24 FF
EN Wall-hung gas boilers WHE 2.24 WHE 2.24 FF User Guide 300011777-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3
More informationC 230 ECO. Control panel. DIEMATIC-m3 (GV6) Installation and Service Manual E
C 230 ECO Control panel DIEMATIC-m3 (GV6) EN Installation and Service Manual 300015243-001-E Contents 1 Introduction.............................................................................3 1.1 Used
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL
CONTROL PANEL RIELLOtech PRIME INSTALLATION, OPERATION AND MAINTENANCE MANUAL CONFORMITY RIELLOtech control panels conform to: Low Voltage Directive 06/95/EC (ex-directive 73/23/EEC) Electromagnetic Compatibility
More informationOil-fired condensing boiler GTU C 330. User Guide B
EN Oil-fired condensing boiler GTU C 330 User Guide 300017846-001-B . Contents 1 Introduction.............................................................................3 1.1 Symbols and abbreviations................................................................................3
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL
INSTALLATION, OPERATION AND MAINTENANCE MANUAL idealtech PRIME CONTROL PANEL For Users Guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured
More informationDTG Eco / V130
ECODENS Gas fired condensing boiler EN User Guide 300010111-001-B Contents 1 Introduction.............................................................................3 1.1 Symbols and abbreviations................................................................................3
More informationWood-burning boiler CBB. User Guide E
EN Wood-burning boiler User Guide 300008541-001-E . Contents 1 Symbols used...........................................................................3 2 Important recommendations...............................................................3
More informationGas-fired boilers DTG 230. User Guide D
EN Gas-fired boilers DTG 230 User Guide 300011506-001-D . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3
More informationSolar station DKP 6-8 / DKP Installation and Service Manual C
EN Solar station DKP 6-8 / DKP 9-20 Installation and Service Manual 300014274-001-C Contents 1 Introduction.............................................................................3 1.1 Used symbols...........................................................................................3
More informationINSTALLATION AND SERVICING
AND SERVICING HARRIER GTS 5-9 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned
More informationMCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI
Vivadens EN Wall-hung gas condensing boilers MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI User Guide 300015874-001-B Contents 1 Introduction...4 1.1 Used symbols...4 1.2 Abbreviations...4 1.3 General...4
More informationLow temperature gas boiler DTG 330 S. User Guide
en Low temperature gas boiler DTG 330 S User Guide 300011852-02 . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3
More informationEURO-OIL SERIES TYPES G.. G../. OR.. OR../. F.. FR..
EURO-OIL SERIES TYPES G.. G../. OR.. OR../. F.. FR.. AUTOMATIC OIL BURNER CONTROL SYSTEMS APPLICATION This range of electronic oil burner controls has been specifically designed for oil burners for non
More informationCONTROL PANEL. RIELLOtech PRIME ACS INSTALLATION, OPERATION AND MAINTENANCE MANUAL
CONTROL PANEL RIELLOtech PRIME ACS INSTALLATION, OPERATION AND MAINTENANCE MANUAL Lecco, 18th January 12 The company Riello SpA Heating Products Direction Via Risorgimento 13 23900 Lecco ITALY hereby declares
More informationVivadens. Wall-hung gas condensing boilers MCR 24/28 BIC. User Guide B
Vivadens EN Wall-hung gas condensing boilers MCR 24/28 BIC User Guide 300024112-001-B Contents 1 Introduction...4 1.1 Symbols used...4 1.2 Abbreviations...4 1.3 General...4 1.3.1 Manufacturer's liability...4
More informationUSER'S INFORMATION MANUAL
USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use
More informationBuccaneer G.T. Installation, Assembly and Servicing. Oil or Dual Gas Fired Boilers
Buccaneer G.T. Installation, Assembly and Servicing Oil or Dual Gas Fired Boilers Assembly and Installation Instructions for Ideal Buccaneer GT Oil, Gas or Dual Fired heating boilers should be read in
More informationInstallation and Instruction Manual
HEATED AIR CURTAIN Installation and Instruction Manual This manual is for Noirot Heated Air Curtains fitted with electronic control boards. For air curtains without electronic control boards please refer
More informationES 140/H ES 160/H ES 180/H ES 200/H ES 220/H ES 260/H ES 300/H ES 340/H ES 380/H
GENERAL Table - Performance Data Boiler ES 40/H ES 60/H ES 80/H ES 00/H ES 0/H ES 60/H ES 300/H ES 340/H ES 380/H Number of Sections 8 9 0 4 6 8 0 Boiler Output nd stage kw 9-40 36-60 53-80 70-00 87-0
More informationinstallation and servicing
installation and servicing Harrier GTE Your Ideal installation and servicing guide GTE 5, GTE 6, GTE, GTE 8 & GTE 9 986 069 When replacing any part on this appliance, use only spare parts that you can
More informationElitec. DTG 1300 Eco.NOx/V. English 23/06/05. Gas-fired boilers. Technical instructions
Elitec DTG 1300 Eco.NOx/V Gas-fired boilers English 23/06/05 Technical instructions Contents Compliance..................................................................................3 Introduction.................................................................................4
More informationLA-Omaggio Operating and Maintenance guide
LA-Omaggio Operating and Maintenance guide INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS FOR OMAGGIO COOKER HOOD Exhausting cooker hood. The equipment is constructed in accordance with European
More informationUSER'S INFORMATION MANUAL
USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use
More informationSemi flush-mount room thermostats
s 1 440 RDD310/EH RDE410/EH Semi flush-mount room thermostats for control of electric floor heating systems and for hydronic zone control systems RDD310/EH RDE410/EH Key features of both types of thermostats:
More informationMikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc
Mikrofill Ethos Condensing combination boiler Maintenance Instructions 24cc IMPORTANT Benchmark Installation, Commissioning and Service Record Log Book is enclosed in your customer information pack. This
More informationInstructions Manual SHC520X - SHC700X
Instructions Manual SHC520X - SHC700X INDEX EN RECOMMENDATIONS AND SUGGESTIONS... 3 CHARACTERISTICS... 4 INSTALLATION... 5 USE... 7 MAINTENANCE... 8 2 RECOMMENDATIONS AND SUGGESTIONS The Instructions for
More informationBSC...E - BSP...E - BESC...E
INISOL DUO E DIETRISOL DUO E Solar hot water calorifer BSC...E - BSP...E - BESC...E EN User Guide 0007781-001-01 Contents 1 Introduction.............................................................................
More informationUSER'S INFORMATION MANUAL
USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use
More informationRVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER
Heating Circuit ZONE Controller RVA 46.531/109 Zonal temperature controller for control of a lowtemperature heating system, for use with condensing gas boilers Instructions for the INSTALLER INDEX Page
More informationUSER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -
USER GUIDE DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER - II CONTENTS 1. SYMBOLS AND WARNINGS... 5 2. GENERAL INFORMATION... 6 3. WARNINGS... 7 4. GENERAL DESCRIPTION... 8 5. INSTALLATION...
More informationUSER'S INFORMATION MANUAL
USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use
More informationOil burners Brûleurs fioul Stookoliebranders
Installation, use and maintenance instructions Manuel d entretien Installatie-, gebruiks- en onderhoudsvoorschriften GB F NL Oil burners Brûleurs fioul Stookoliebranders One stage operation Fonctionnement
More informationES 140/H ES 160/H ES 180/H ES 200/H ES 220/H ES 260/H ES 300/H ES 340/H ES 380/H
GENERAL Table - Performance Data Boiler ES 0/H ES 0/H ES 80/H ES 00/H ES 0/H ES 0/H ES 00/H ES 0/H ES 80/H Number of Sections 8 9 0 8 0 Boiler Output nd stage kw 9-0 -0-80 0-00 8-0 -0-00 89-0 -80 st stage
More informationHG 675 CX 60 HG 675 CN 60 HG 675 CW 60
HG 675 X 60 HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 1 2 1. : 93/68: 90/396: 2006/95/CE: 2004/108/CE: - 1935/2004:. 2002/95/CE: RoHS 2.,.,,,,...,. (,..)..,,.,. ( ),,, ;,,.,.....,.,,,,,,...,. (..),,.,..,.,,,,
More informationSOLNEO SGC 24 SOL. User Guide. Gas fired condensing boiler C
SOLNEO EN Gas fired condensing boiler SGC 24 SOL User Guide 300017555-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols and abbreviations................................................................................3
More informationService manual. Riva Plus HE. M296.28SR/C System boiler. Wall hung, fanflue, roomsealed, high efficiency gas boiler
Wall hung, fanflue, roomsealed, high efficiency gas boiler Service manual Riva Plus HE Models G.C. ppl. No. M296.24SR/C 41-583-18 System boiler M296.28SR/C 41-583-19 System boiler Leave this manual adjacent
More informationDIEMATIC VM isystem WALL-MOUNTED CONTROL SYSTEM. DIMENSIONS Length: 320 mm Height: 260 mm Depth: 130 mm. POWER SUPPLY 230 V, 50 Hz, 6 A
DIEMATIC WALL-MOUNTED CONTROL SYSTEM Electronic control system capable of controlling 2 heating circuits, a DHW circuit and an auxiliary circuit EC identification No.: 0085CM0178 Electronic microprocessor
More informationEUROFLAT SERIES TYPES C... S... M...
EUROFLAT SERIES TYPES C... S... M... AUTOMATIC CONTROL SYSTEMS FOR GAS BURNERS AND GAS BURNING APPLIANCES WITH OR WITHOUT FAN APPLICATION The electronic systems of this range are suitable to control gas
More informationMICROFLAT SERIES TYPES C.../U T X
MICOFLAT SEIES TYPES C.../U T X AUTOMATIC GAS BUNE CONTOL SYSTEMS FO GAS BUNES AND GAS BUNING APPLIANCES WITH O WITHOUT FAN APPLICATION This range of electronic gas burner control systems is suitable for
More informationTECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE:
TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE: 560955 CE Directive 2006/95/CEE British Standard EN 60335-1 (C 73800) 1 CONTENTS Page 1) INTRODUCTION 1.1) Description 3 1.2) Dimensions & connections
More informationHeat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER
Heat 45 & 55 User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER CE/PI No. 86-CN-69 Heat 45 - GC No. 41-930-40 Heat 55 - GC No. 41-930-41 These instructions
More informationCARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER
CARVER - CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER 1:0 SPECIFICATIONS Water capacity Water connections Water supply 9 litres (2 gallons)
More informationParts Available from
Montage und Bedienungsanleitung Manuel d entretien Installation, use and maintenance instructions Installatie-, gebruiks- en onderhoudsvoorschriften Oδηγίες εγκατάστασης, χρήσης και συντήρησης D F GB NL
More informationInstallation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE
Installation instructions For the competent person Installation instructions VRT 350 VRT 350 GB, IE Legal information Document type: Product: VRT 350 Target group: Language: Installation instructions Authorised
More information51AKB / 51 AKC OWNER S MANUAL
51AKB / 51 AKC OWNER S MANUAL This manual applies to the following models 51AKB 009 51AKB 012 51AKC 009 51AKC 012 Read this instruction manual thoroughly before using the air conditioner. Control panel
More informationINSTRUCTION FOR THE USER THC V E OIL BLU
INSTRUCTION FOR THE THC V E OIL BLU CONTENTS General safety information 4 Precautions 4 Control panel 5 Mode selection 8 User levels 10 Start-up 12 Temporary shutdown 15 Preparing for extended periods
More informationUSER'S INFORMATION MANUAL
USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use
More informationK20 K40 ICEMAKER INSTRUCTIONS
K20 K40 ICEMAKER INSTRUCTIONS Environmental Hints Packing Do not throw the packing into the garbage: first sort out the different materials (i.e.: steel, cardboard, polystyrene) following local regulations.
More informationInstallation Instructions VITOTRONIC 200
Installation Instructions Please file in Service Binder Vitotronic 200 Model KW2 Weather-responsive indoor/outdoor, digital boiler control for heating systems with one or more heating circuits VITOTRONIC
More informationINSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS
INSTALLATION AND OPERATING INSTRUCTIONS HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS INDEX 1. Technical information... page 3 2. Dimensional and technical characteristics... page 3 3. Packing
More information1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY
RC 06 0712_1403 it - Istruzioni TELECONTROLLO en - Remote controller instruction hu - Utasítás TÁVVEZÉRLÉS ru - Руководство по эксплуатации pl - Instrukcja obsługi { 1. Commissioning of the boiler 26 2.
More informationService manual GARDA HE MK2. M96A.24SM/B Combi boiler M96A.28SM/B Combi boiler
Wall hung, fan flue, room sealed, high efficiency gas boiler Service manual GRD HE MK2 Models: G.C. ppl. No. M96.24SM/ 47---583---15 Combi boiler M96.28SM/ 47---583---16 Combi boiler Leave this manual
More information2. General information Page Warnings Page Technical characteristics Page Installation Page Front panel Page 7
INDEX 1. Symbols and warnings Page 3 2. General information Page 4 3. Warnings Page 5 4. Technical characteristics Page 6 5. Installation Page 6 6. Front panel Page 7 7. Set-up and calibrations Page 8
More informationServicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use
GB122 7210 1300-12/2002 GB(EN) For trade use Servicing manual Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C Please read thoroughly before attempting to diagnose fault List of contents
More informationInstallation & Operation Manual
tekmarnet 2 House Control 400 Installation & Operation Manual D 400 09/10 HVAC Systems Replaces: 01/10 Introduction The House Control 400 is designed to operate as part of a complete hydronic heating system
More informationInstallation & Operation Manual
tekmarnet 2 House Control 400 Installation & Operation Manual D 400 09/13 HVAC Systems Replaces: 09/10 Introduction The tn2 House Control 400 is designed to operate all of the mechanical equipment in a
More informationBritish Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:
0020051423-02 10.07 British Gas 330+ High Efficiency Condensing Boiler Instructions for Use To b e l e f t w i t h t h e u s e r British Gas Service Tel: 0845 9500400 WARNING GAS LEAK OR FAULT Turn off
More informationServicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use
GB122 Servicing manual Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C For trade use Please read thoroughly before attemting to diagnose fault 7217 4900 (03/2010) GB/IE List of contents
More informationOPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19
OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER Version DC19 1. Application. Controller RK-2006LPP is designed for temperature control of solid fuel fired water boilers
More informationInstallation and Operating Instructions
Installation and Operating Instructions Models: Verso 4G Hob As part of Parmco Appliances commitment to improving and updating product ranges, we reserve the right to alter, change and update technical
More informationSMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS
SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS CONTENTS 1. INTRODUCTION... 5 2. WARNINGS... 6 3. GENERAL DESCRIPTION... 7 4. INSTALLATION... 8 5. LUMINOUS INDICATORS AND COMMANDS... 9 6. DIP-SWITCH
More informationAQUARIUS 45 MARINE SERVICE MANUAL
AQUARIUS 45 MARINE SERVICE MANUAL CONTENTS: PAGE 1. INTRODUCTION 3 2. SAFETY INSTRUCTIONS 4 3. BASIC INSTRUCTIONS 5 3.1. Installation Details 5 3.2. Operating the Boiler for the First Time 6 3.3. Troubleshooting
More informationFor the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control
For the owner and the heating engineer Operating and Installation Manual VRC 400 Programmable weather compensator with separat HW time control GB Contents Contents Notes on the documentation..... 4 Symbols
More informationSPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model MICROGENUS PLUS. R EN - Edition 02-01/04/2007
SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model MICROGENUS PLUS R8215343-02EN - Edition 02-01/04/2007 Domestic Gas Boilers MICROGENUS PLUS 537814 MICROGENUS PLUS 24 MET...... 3300078 MICROGENUS PLUS 21
More information1. Information before installation General terms of delivery, storage and transport
EN Read this manual carefully before installing, maintaining or repairing this device! The symbol indicates important information that must be taken into account in order to avoid risk of personal injury
More informationStainless Steel Chimney Extractor
Stainless Steel Chimney Extractor HJA2450-2 User & Installation Guide LAMONA Appliances Dear Customer, Congratulations on your choice of a LAMONA domestic appliance which has been designed to give you
More informationFor the heating engineer. Installation manual. Interface 0-10V VR34
For the heating engineer Installation manual Interface 0-10V VR34 GB Contents Contents 1 Notes on the documentation...3 1.1 Storage of the documents...3 1.2 Symbols used...3 2 Safety instructions and regulations...4
More informationResidential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...
70 80 99-00-O Residential Gas Condensing Boiler ZBR//8/35/4-3A... ZWB8/35/4-3A... 70 80 993 (03/03) CA/US Operating Instructions Contents Contents Key to symbols and safety instructions............................
More informationInstruction manual. WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules
Instruction manual WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules This manual must only be used by a qualified heating installer/service technician.
More informationT UNI 7000 F. Operating instructions For the user (2006/05) AU/GB
6 720 648 662-00.1T UNI 7000 F Operating instructions For the user AU/G 2 Contents Contents Contents 2 1 Safety information and explanation of symbols 3 1.1 For your safety 3 1.2 Explanation of symbols
More informationGas fired condensing boiler C 230 ECO. User Guide C
EN Gas fired condensing boiler C 230 ECO User Guide 300015144-001-C Contents 1 Introduction.............................................................................3 1.1 Used symbols...........................................................................................3
More informationStainless Steel Chimney Extractor
Stainless Steel Chimney Extractor User & Installation Guide LAM2404 LAMONA Appliances Dear Customer, Congratulations on your choice of a LAMONA domestic appliance which has been designed to give you excellent
More informationEUROBOX SERIES TYPES CM... SM... MM...
EUROBOX SERIES TYPES CM... SM... MM... AUTOMATIC GAS BURNER CONTROL SYSTEMS FOR GAS BURNERS AND GAS BURNING APPLIANCES WITH OR WITHOUT FAN Application This range of electronic gas burner control systems
More informationInstallation, operating and servicing instructions
English 57-115 - 144-1 - 259 Installation, operating and servicing instructions ITALIA EN 1 ITALIA English INDEX WARnINGS 3 Who should read these instructions 3 Symbols 3 Recommendations 3 Importants notes
More informationInstallation Manual NPE-180A/240A WARNING. Add-on Controller Installation Kit
Installation Manual Add-on Controller Installation Kit NPE-180A/240A This device is designed to work with NPE-180A/240A models ONLY. WARNING All Installations should be done only by a qualified expert
More informationSPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model CLAS. R EN - Edition 01-01/02/2007
SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model CLAS R8215828-01EN - Edition 01-01/02/2007 3300187 CLAS 24 NG (EAA1)...... 3300189 CLAS 24 CF NG (EAA1)...... 3300188 CLAS 28 NG (EAA1)...... Reference
More informationEDENA CLASSIC E. Model : kw INTALLATION AND SERVICING INSTRUCTIONS. Gas Fired Floor Standing Boiler. Réf. : CH I EN 09/05
INTALLATION AND SERVICING INSTRUCTIONS EDENA CLASSIC E Model : 35-43 - 53-64 kw Gas Fired Floor Standing Boiler N04266.DSF Réf. : CH - 1254 - I - 0 - EN 09/05 1 Réf. : CH - 1254 - I - 0 - EN Contents 1.0
More informationAlpha CombiMax 350 and 600
Installation and Servicing Instructions Alpha CombiMax 350 and 600 Unvented Hot Water Store for use with the Alpha 240/280 Range of Gas Fired Combination Boilers For Technical help or for Service call...
More informationSolar regulator DIEMASOL C. Installation and Service Manual. User Guide G
EN Solar regulator DIEMASOL C Installation and Service Manual User Guide 300005750-001-G . Copyright All sections of these instructions for installation and use are protected by copyright. Any use likely
More informationInstallation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A
Installation Manual Add-on Controller Installation Kit NPE-180A/210A/240A This device is designed to work with NPE-180A/210A/240A water heaters ONLY. WARNING All Installations should be done only by a
More informationContact Details. Please note that some of the contact details on this PDF document may not be current.
Contact Details Please note that some of the contact details on this PDF document may not be current. Please use the following details if you need to contact us: Telephone: 0844 879 3588 Email: customer.services@gdcgroup.co.uk
More informationI n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600
I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d Model code: BORA600 Contact Caple on 0844 8003830 or for spare parts www.4caple.co.uk 1 Y O U R A P P L I A N C E Thank you for buying your
More information>> >> >> High technology with oil. High performance modulating burner Compact boiler design. Compatible with renewable energies. Sustainable Comfort
Ecodesign by FLOOR-STANDING OIL CONDENSING BOILER ADVANCE High technology with oil >> >> >> High performance modulating burner Compact boiler design Compatible with renewable energies SOLAR SOLID FUEL
More informationInstallation & Operation Manual
tekmarnet 2 House Control 402 Installation & Operation Manual D 402 09/10 HVAC Systems Replaces: 01/10 Introduction The House Control 402 is designed to operate as part of a complete hydronic heating system
More informationInstallation & Operation Manual
tekmarnet 2 House Control 403 Installation & Operation Manual D 403 07/11 HVAC Systems Replaces: 09/10 Introduction The House Control 403 is designed to operate as part of a complete hydronic heating system
More informationPC 640 GB. Built-in cooking tables 60 Instructions for installation and use
PC 640 GB Built-in cooking tables 60 Instructions for installation and use Congratualtions on choosing an Ariston appliance, which you will find is dependable and easy to use. We recommend that you read
More informationSERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS
SERIES 35-65 24 VAC Microprocessor-Based Hot Surface Ignition Control F-35-65 August 2015 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge and inter-purge timings* 120/240
More information