1 EN Solar station DKP 6-8 / DKP 9-20 Installation and Service Manual C
2 Contents 1 Introduction Used symbols General Electrical compliance Safety instructions and recommendations Technical description General description Technical characteristics Pump unit Accelerator pump Airstop/degasser Antithermosiphon valve Installation Fitting the vent device (Airstop) to the solar heat exchanger inlet Fitting the pumping unit to the solar heat exchanger outlet Fitting to the solar station, steps to be followed: Connecting the pipe circuit to the solar station Assembling the pipes Hydraulic connections Wall connection kit for expansion vessel Dimensioning the expansion vessel Electrical connection Commissioning Spare parts - DKP 6-8 / DKP DKP 6-8 / DKP /07/ C
3 1 Introduction 1.1 Used symbols Caution danger Risk of injury and damage to equipment. Attention must be paid to the warnings on safety of persons and equipment. Specific information Information must be kept in mind to maintain comfort. Reference Refer to another manual or other pages in this instruction manual. 1.2 General The manufacturer is not liable for any improper use of the appliance or failure to maintain or install the unit correctly (the user shall take care to ensure that the system is installed by a qualified fitter). For a proper operating of the boiler, follow carefully the instructions. Keep these instructions in a safe place close to the appliance. 1.3 Electrical compliance This product complies to the requirements to the European Directives and following standards: /95/EC Low Voltage Directive Reference Standard: EN /108/EC Electromagnetic Compatibility Directive Reference Standards: EN / EN / EN Safety instructions and recommendations Any operation on the installation must be performed by a qualified technician respecting professional regulations and in accordance with this document. Service the appliance regularly to ensure that it operates correctly. To take advantage of the guarantee, no modifications must be made to the appliance. 06/07/ C DKP 6-8 / DKP
4 3 Technical description 3.1 General description The solar station includes a safety valve, an expansion vessel connection and a filling device. 3.2 Technical characteristics Solar station Height (with insulation) 630 mm Width (with insulation) 200 mm Depth 190 mm Maximum operating pressure 6 bar Maximum operating temperature 120 C (on occasion 180 C) Safety devices Safety valve 6 bar Connection kit for expansion vessel current Retaining / signalling components Spherical liner valve Mk3/4 Antithermosiphon valve Resistance 200 mm water columns Execution Mod. PPS can be fitted Maximum operating temperature 180 C Sealing material VILTON/EPDL O-ring 180 C AFM 34 gaskets 200 C Insulation Material EPP 3.3 Pump unit Accelerator pump High manometric pump: ST 20/6 - ST 20/9 Power exchanged 4 DKP 6-8 / DKP /07/ C
5 3.3.2 Airstop/degasser The solar station is fitted with a permanent degassing device (Airstop) on the flow pipes. The circulator conveys any air bubbles present to the Airstop system. The air contained in the heatexchanging medium is collected in the degasser. The degasser must be vented from time to time (several times after commissioning, then after one week followed by a further check after one month). For optimum efficiency, the solar installation must be vented using the degasser every six months. After venting, the installation operating pressure must be reset Antithermosiphon valve The check valve is included in the ball valve on the red thermometer and it is characterized by an opening pressure of 200 mm water column. 1. To fill, vent and rinse the installation, the antithermosiphon valves must be open. To open them, use a 14 mm openended spanner and open the valves half way. The ball in the valve lifts the check valve (45 ). 2. When the installation is operating, the ball valves must be fully open. The antithermosiphon valve operates when the stop cock is in the open position. 06/07/ C DKP 6-8 / DKP
6 4 Installation 4.1 Fitting the vent device (Airstop) to the solar heat exchanger inlet Screw the vent device to the top solar connection. First place the gasket in the coupling nut. 4.2 Fitting the pumping unit to the solar heat exchanger outlet Hold the pumping unit in place with the insulation housing on the tank and screw it onto the bottom solar connection. First place the gasket in the coupling nut. M A 6 DKP 6-8 / DKP /07/ C
7 4.3 Fitting to the solar station, steps to be followed: 1. Attach the control system to the mounting base frame provided. 6. Remove the part of the casing in plexiglass from the front insulation housing. Fit the front insulation housing without plexiglass but with control system to the solar station. The control system is now fitted and can be set from the front. 7. Drill a hole 8 in the side cover and feed through the DHW sensor. 8. Fitting the DHW sensor. 9. Refit the cover M A 2. Secure the control system on the mounting base frame to the station, above the pump. D B 10. Connect the connector delivered with the solar station to the circulator. M A 3. Fit the wiring between the pump and the control system. 4. Connect the tank sensors and the solar collectors. 5. Make the 230 V connection (qualified personnel only). Electrical connections, cf. commissioning the Diemasol A control system. 06/07/ C DKP 6-8 / DKP
8 4.4 Connecting the pipe circuit to the solar station Recommendation: connect the flow and the return according to the instructions in the illustration. If need be, it is nonetheless possible to modify the return by turning the valve block from left to right. After completing the solar circuit, filling it and checking the pressure, it is possible to fit the front housing to the station. 4.5 Assembling the pipes If connecting by brazing: - Strong brazing on joints to be brazed without scouring agent/ paint stripper. - Remove the rubber gasket before brazing. - Put the gasket back in place after brazing. The arrow on the pump must be pointing towards the roof ridge. Make the connections using clamping ring screw connections. With small systems, use De Dietrich propylene glycol containers to recover fluid under the safety valve discharge pipe. 8 DKP 6-8 / DKP /07/ C
9 4.6 Hydraulic connections Wall connection kit for expansion vessel The connection kit includes a 0.5 metre long stainless steel hose with nuts for pipe unions and flat gaskets for both sides as well as an arm and a screw connection supporting the expansion vessel. The connecting hose is arranged in such a way as to be able to fit the expansion vessel to the wall, beside the hot water tank. If the appliance is not installed against a wall, the installer must fit an extension (copper pipe) connecting the expansion vessel or connect the expansion vessel to the conduit coming out of the top of the hot water tank. If, due to lack of space, the arm cannot be mounted as such, it can be used as a floor-standing support. In this case, the opened expansion vessel is fitted in the horizontal position Dimensioning the expansion vessel The volume of the expansion vessel depends above all on the volume likely to be vapourised when the installation is switched off. For this reason, the expansion vessel must be chosen according to the number of collectors. When the number of collectors is high, parallel expansion vessels can be fitted. PRO PRO C POWER Collecto r surface Number of panels Total length of the pipe A/R < 30m A/R >30m Volume of the expansion vessel m 2 ø ext. (mm) ø ext. (mm) litres 5 15/18 15/ /18 15/ / / /18 15/ /18 15/ /18 15/ /18 15/ Expansion vessel capacity: Pre-inflation and pressure in the installation must be adapted to the configuration of the installation. Package no. Volume of the expansion vessel EG EG EG /07/ C DKP 6-8 / DKP
10 4.7 Electrical connection Make the 230 V connection (qualified personnel only). Electrical connections, cf. commissioning the Diemasol A control system. 5 Commissioning See: Domestic hot water tank manual. 10 DKP 6-8 / DKP /07/ C
11 6 Spare parts - DKP 6-8 / DKP 9-20 To order a spare part, quote the reference number next to the part required. 06/07/ C 9 A000646A Ref. Reference Description Insulation for DKP 6-8 solar station Part in plexiglass R 3/4 connection cross /4 double nipple Rp 3/4 return valve with antithermosiphon valve Circulator ST20/ DKP Circulator ST20/9-3 - DKP Flow valve Elbow R 3/ Drain cock Bleeder valve stopper 3/8" (after 06/2007) Degasser M/M 3/4" (after 06/2007) Air vent R 3/4 (before 06/2007) Safety device holder Solid plug R 3/ Manometer connection point bar manometer Ref. Reference Description bar safety valve Sachet of gaskets for DKP 6-8 solar station x3 O-ring 06/07/ C DKP 6-8 / DKP
12 Copyright All technical and technological information contained in these technical instructions, as well as any drawings and technical descriptions supplied, remain our property and shall not be multiplied without our prior consent in writing. Subject to alterations. 06/07/09
CIRCO 6 Solar Circulation Unit
TECHNICAL INFORMATION / INSTALLATION INSTRUCTIONS CIRCO Solar Circulation Unit CIRCO Solar Circulation Unit in combination with the intelligent SUNGO controllers, it is the safe and reliable heart of a
More informationInstallation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25
PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and operation instructions Solar stations SolarBloC
More informationInstallation and instruction manual SOLAR STATION
INSTALLATION AND INSTRUCTION MANUAL SOLAR STATION Installation and instruction manual SOLAR STATION SST 25-1E / SST25-2E EN April 2015 1 Table of contents Usage 3 Warranty 3 Safety instructions and symbol
More informationTRIO DT 350/3 DIETRISOL. Solar domestic hot water tanks. Installation instructions. Instructions for use. Technical instructions.
DIETRISOL TRIO DT 350/3 Solar domestic hot water tanks English 07/11/06 Installation instructions Instructions for use 8980N146A Technical instructions Contents Introduction.................................................................................3
More informationBSC...E - BSP...E - BESC...E
INISOL DUO E DIETRISOL DUO E Solar hot water calorifer BSC...E - BSP...E - BESC...E EN User Guide 0007781-001-01 Contents 1 Introduction.............................................................................
More informationWHE 2.24 / WHE 2.24 FF
EN Wall-hung gas boilers WHE 2.24 WHE 2.24 FF User Guide 300011777-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3
More informationInstallation, operation and care Wall-mounted electric boiler MP THL nr. - rev 02
Installation, operation and care Wall-mounted electric boiler MP 4 150206 THL nr. - rev 02 Contents Notes... 3 Safety and handling... 4 Operation... 5 Technical data... 6 Pipe installation... 8 System
More informationSolar heating systems
03 energy efficiency Compact, "ALL-IN-ONE" solar system Solar panel for swimming pools Hydraulic components Drain-Unit: dual hydraulic unit with drain back system Drain-Unit: hydraulic unit with drain-back
More informationAGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE
INSTRUCTION MANUAL INSTALLATION AND SERVICING AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE About this manual These installation and maintenance instructions contain important information
More informationMAIN FEATURES ADVANTAGES BENEFITS BOSS TRANSFORMER COMBI HF 110 CHEMICAL AND PHYSICAL FEATURES PACKAGING FEATURES
BOSS TRANSFORMER COMBI HF 110 Power flushing pump with antacid vertical axis. Suitable for domestic and medium dimensions systems. Practical trolley design with 110 litres tank. COD. 301301006 CHEMICAL
More informationPRIUX HOME D. High-efficiency double circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE APPLICATIONS BENEFITS
OPERATING RANGE Flow rate of up to 7 m /h* Manometric head of up to 8 mwc Max. operating pressure bar Min. suction pressure, bar at 9C Temperature range -C at 9C Max. ambient temperature +C EEI-Part Priux
More informationDEVIATING VALVES ART K063
FUNCTION The flow diverter valve Art.307 makes it possible to supply a branch circuit. Prepared to receive our electro-thermal controls Art. 978, 979, 980 or our thermostatic heads with remote sensor Art.
More informationCONNECT SOLAR MR - 7,5m
Installation Manual CONNECT SOLAR MR - 7,m Solar Solar station EN Installation Manual 0 6 GENERAL INFORMATION ENGLISH General information This - comprises pages. Rev. manual, Code RANGE MODEL CODE CONNECT
More informationRemeha. Fuel oil/gas boilers P 520. Installation and Service Manual A
Remeha Fuel oil/gas boilers EN Installation and Service Manual 300016859-001-A 63115 Declaration of conformity The appliance complies with the standard model described in declaration of compliance. It
More informationInstallation & Operation Manual Models: TSU
TSU-I-O Rev A Installation & Operation Manual Models: TSU 150-940 CAUTION: This appliance is not intended for potable water. This manual must only be used by a qualified heating installer / service technician.
More informationInstallation, Operating and Servicing Instructions
EN 0 / 0 / 00 / 800 Installation, Operating and Servicing Instructions excellence in hot water EN Y000.D EN INDEX Warnings Who should read these instructions Symbols Recommendations Applicable standards
More informationCrown Boiler Company
Crown Boiler Company 1 Phantom Boiler System Combi Kit Instruction Manual I Product Description This kit adds the ability to generate DHW, as well as heat, ( combi capability) to select Phantom models
More informationHeatMaster. Assembling and installation instructions. 201 Booster. HeatMaster. HeatMaster. 200N (Gas) Booster ENGLISH FRANCAIS NEDERLANDS ESPAÑOL
Heataster Assembling and installation instructions Heataster 201 Booster Heataster 200N (Gas) Booster EN 1 WANINGS 3 Who should read these instructions 3 Symbols 2 Applicable standards 2 ecommendations
More informationGeneral System Layout Sketch
General System Layout Sketch EZ-37 Solar Panels PV panel Glycol Fill Valve Expansion Tank ` 1 Introduction This document describes how to install a Heliatos GH type solar water heating system. These systems
More informationComponents for solar heating systems
solarorkli Components for solar heating systems Components for heating and plumbing Components for solar heating systems Manifolds and distribution equipment Thermostatic valves Manual valves Motorised
More information8008 CIRCULATION UNIT FOR SOLAR THERMAL SYSTEMS, FLOW AND RETURN.
8008 CIRCULATION UNIT FOR SOLAR THERMAL SYSTEMS, FLOW AND RETURN. FUNCTION: Circulation units for solar thermal systems are used in the primary circuit of solar heating systems to control the temperature
More informationHKF 8180 Operating instructions
Operating instructions EN Version 1.0en /Edition 05/2013 Contents 1 Important basic information... 3 1.1 Limitation of liability... 3 1.2 Operator's responsibilities... 3 1.3 Documentation... 3 1.3.1 Content
More informationPowerstock Storage Tank
Powerstock Storage Tank Models ST300, ST500, ST750 & ST1000 INSTALLATION, COMMISSIONING AND SERVICING INSTRUCTIONS THE POWERSTOCK STORAGE TANK IS INTENDED FOR USE AS A COMMERCIAL APPLIANCE. PUBLICATION
More informationINSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHTS200A EKHTS260A EKHTSP200AA EKHTSP260AA
INSTALLATION MANUAL Domestic hot water tank for air to water heat pump system EKHTS00A EKHTS60A EKHTSP00AA EKHTSP60AA 6 7 x x x x x x x 0 mm 0 D B >0 C >0 0 >0 A >600 H 0 Ø60 0 0 77 8 6 7 778 6 0 6 6 00
More informationUSER S MANUAL ATH WH220
USER S MANUAL ATH WH220 INDEX INTRODUCTION... - 3 - General information s... - 3 - Description of pneumatic jack... - 4 - Operation of jack... - 5 - Technical data... - 6 - Dimension drawing... - 6 - INSTALLATION...
More informationAGS 5/5E, AGS 10/10E INSTALLATION AND SERVICING INSTRUCTIONS SOLAR PUMP STATIONS FOR SEALED SOLAR HEATING SYSTEMS AND INDIRECT FED DOMESTIC HOT WATER
INSTALLATION AND SERVICING INSTRUCTIONS SOLAR PUMP STATIONS AGS 5/5E, AGS 0/0E FOR SEALED SOLAR HEATING SYSTEMS AND INDIRECT FED DOMESTIC HOT WATER 7747006489.00-.SD CONTENTS CONTENTS Safety instructions
More informationInstallation, Operating and Servicing Instructions
ENGLISH 0 / 0 / 0 / 0 / 00 Installation, Operating and Servicing Instructions FRANCAIS NEDERLANDS ESPAÑOL Y000.A EN ESPAÑOL NEDERLANDS FRANCAIS ENGLISH INDEX WARNING Who should read these instructions
More informationEnzo Concealed Shower Mixing Valve
Enzo Concealed Shower Mixing Valve EZ40010CP, EZ40013CP & EZ40014CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible.
More informationInstallation and Operation Manual IDRA PLUS DS. Solar Solar storage cylinder. Installation and Operation Manual
Installation and Operation Manual IDRA PLUS DS Solar Solar storage cylinder EN Installation and Operation Manual GENERAL INFORMATION This - comprises pages. Rev. manual, Code ENGLISH General information
More informationVIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l
Installation instructions for contractors VIESMANN Vitocell 300-B Type EVBA-A Dual mode DHW cylinder, 300 and 500 l VITOCELL 300-B 1/2017 Dispose after installation. Safety instructions Please follow these
More informationEnzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP
Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot
More informationPHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE
TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE
More informationOperating Instructions. Boilermag XL Filter. High Intensity Magnetic Separator
Operating Instructions Boilermag XL Filter High Intensity Magnetic Separator Technical data is subject to change without notice due to technical innovation! Eclipse Magnetics Ltd Atlas Way, Atlas North,
More informationEXTREME 1 Reverse Osmosis System
EXTREME 1 Reverse Osmosis System Leader Evaporator Co., Inc. 49 Jonergin Drive Swanton, VT 05488 Tel: 802-868-5444 www.leaderevaporator.com TABLE OF CONTENTS INTRODUCTION... 4 THEORY OF OPERATION... 4
More informationPLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL
PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION SOLARCYL IM/SC INSTALLATION MANUAL This manual gives detailed advice for installation and should be read carefully prior to fitting any unvented
More informationHakki Pilke Raven spare parts manual
1 ENGLISH Hakki Pilke Raven spare parts manual Valimotie 1, FI-85800 Haapajärvi, FINLAND Tel. +358 8 772 7300, Fax +358 8 772 732 info@maaselankone.fi, www.maaselankone.fi 2 Table of contents 1 Upper section
More informationMCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI
Vivadens EN Wall-hung gas condensing boilers MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI User Guide 300015874-001-B Contents 1 Introduction...4 1.1 Used symbols...4 1.2 Abbreviations...4 1.3 General...4
More informationAquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes
Thermostatic valve with adjustable temperature control range Technical information Tender specification: Oventrop thermostatic valve Aquastrom T plus with presetting for circulation pipes. Thermal control
More informationIllustration shows item no Z Original operating manual. Operating manual. BlueMobil eco. Item no: Z-3278
Illustration shows item no Z-3278 Operating manual BlueMobil eco Item no: Z-3278 Original operating manual Important Copyright It is essential that you read this manual thoroughly before the initial operation
More informationIST 03 C CYLINDER WHPF BM USE AND MAINTENANCE HANDBOOK
IST 03 C 185-01 CYLINDER WHPF BM USE AND MAINTENANCE HANDBOOK GB ES Dear Customer, Thank you for choosing our company and our hot water cylinder. Please read these instructions carefully. Cylinder correct
More informationMoisture inside the drum is due to final testing.
Safety instructions Scope of delivery depending on model Moisture inside the drum is due to final testing. Removing the transport safety devices Water connection depending on model The washing machine
More informationSPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model MICROGENUS PLUS. R EN - Edition 02-01/04/2007
SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model MICROGENUS PLUS R8215343-02EN - Edition 02-01/04/2007 Domestic Gas Boilers MICROGENUS PLUS 537814 MICROGENUS PLUS 24 MET...... 3300078 MICROGENUS PLUS 21
More informationMetering systems 0548EN April 2014
08EN April 0 0U8 GEY - Y - Y (GE- series) 900 000/ 00 00A/ 800 00L/ Versions and product codes Product code Type Heat exchanger nominal power GEY, - GEY and production GEY and production Table - Product
More informationOperating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents
1.0 Table of Contents 1.0 Table of Contents... 1........................................................................ 2 2.0 Functional description... 3 3.0 Safety notes... 4 3.1 Safety Notes general............................................
More informationContents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9
Contents Product Description 2 Approvals 2 Warranty 2 Warnings 2 Technical Specification 3 Installation 4 Location 4 Plumbing Connection 4 Electrical connection 5 Commissioning 6 Operation 6 Routine Preventative
More information- 1- IMPORTANT SAFETY REMINDERS
USER MANUAL IMPORTANT SAFETY REMINDERS This appliance should only be used for domestic cleaning, as described in this user guide. Please ensure that this guide is fully understood before operating the
More informationInstallation Instructions
Installation Instructions The energy you need Accessories/PFGHRD 60/100 Passive Flue Gas Heat Recovery Device Explanation of Symbols a DANGER: Risk of injuries. The PFGHRD is an integral part of the flue
More informationPLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL
PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION 0 RD 0 RI 0000-06 IM/ IM/a INSTALLATION MANUAL This manual gives detailed advice for installation and should be read carefully prior to fitting
More informationHG 675 CX 60 HG 675 CN 60 HG 675 CW 60
HG 675 X 60 HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 1 2 1. : 93/68: 90/396: 2006/95/CE: 2004/108/CE: - 1935/2004:. 2002/95/CE: RoHS 2.,.,,,,...,. (,..)..,,.,. ( ),,, ;,,.,.....,.,,,,,,...,. (..),,.,..,.,,,,
More informationLINDOFLAMM thermal engineering.
Catalogue LINDOFLAMM thermal engineering. Tailored solutions for every heating application. 02 LINDOFLAMM thermal engineering. Tailored solutions for every heating application. Contents. 03 All-round offering
More informationInstallation Guide. Termix Distribution unit. 1.0 Table of Contents. 1.0 Table of Contents
1.0 Table of Contents 1.0 Table of Contents... 1........................................................................ 2 2.0 Functional description... 3 3.0 Safety notes... 4 3.1 Safety Notes general............................................
More informationOblo Basin and Bidet Monobloc Installation and User Guide
Oblo Basin and Bidet Monobloc Installation and User Guide MODEL NUMBERS 10085W-CP, 10088W-CP Important! Please quote the above model number(s) when ordering spares IMPORTANT Installer: This manual is the
More informationInstallation Manual STOR C. Solar combination storage cylinder. Installation Manual
Installation Manual STOR C Solar combination storage cylinder EN Installation Manual 2MANUALE INSTALLATORE Dear Installer, Thank you for choosing a BERETTA STOR C, combination storage cylinder. You have
More informationMETRO BASIN MONO MIXER CHR
METRO BASIN MONO MIXER CHR 20004010020 This product should only be fitted by a qualified plumber to NVQ (National Vocational Qualification) or SNVQ (Scottish National Vocational Qualification) Level 3.
More informationLYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS
www.regulus.eu LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE EN LYRA 1000 VVS CONTENTS 1 Description... 3 1.1 Models... 3 1.2 Tank protection... 3 1.3 Thermal insulation...
More informationAccumulator tank. 1000, 750 and 500 litres Aqualux Teknik Aqualux UB Aqualux 750 CU
Installation, operation and maintenance Accumulator tank 1000, 750 and 500 litres Aqualux Teknik Aqualux B Aqualux 750 C Aqualux 750 Teknik with bivalent shunt, optional extra 2012-02-08 ver.: Supersedes:
More informationPARTS BOOK. From S/N:
PARTS BOOK From S/N: 4486 All spares available from The Engine Shed Top Station Road Brackley NN UG Tel: 084 08060 Fax: 080 844 Web: www.caterparts.com Copyright Notice: All rights reserved. No parts of
More informationEXTREME HP-1 Reverse Osmosis System
EXTREME HP-1 Reverse Osmosis System Leader Evaporator Co., Inc. 49 Jonergin Drive Swanton, VT 05488 Tel: 802-868-5444 www.leaderevaporator.com TABLE OF CONTENTS INTRODUCTION... 4 THEORY OF OPERATION...
More informationM07. Wunda Premium Manifold. Before you start: Check the contents THE BRAND YOU CAN TRUST
Before you start: Check the manifold box contents against the list below. Check the contents 1. 2 x Manifold end blanks 2. 2 x Manual air vent & drain cocks 3. 2x Adjustable mounting brackets 4. Manifold
More informationVivadens. Wall-hung gas condensing boilers MCR 24/28 BIC. User Guide B
Vivadens EN Wall-hung gas condensing boilers MCR 24/28 BIC User Guide 300024112-001-B Contents 1 Introduction...4 1.1 Symbols used...4 1.2 Abbreviations...4 1.3 General...4 1.3.1 Manufacturer's liability...4
More informationR146C. Adjustable magnetic dirt separator. Versions and product codes. Datasheet 0840EN 10/2018
R146C Adjustable magnetic dirt separator Datasheet 0840EN 10/2018 The R146C adjustable magnetic dirt separator separates and removes debris inside hydraulic circuits of modern heating and cooling systems.
More informationHigh-efficiency circulating pumps Heating Air conditioning 50 Hz
OPERATING RANGE Flow rate of up to m /h Manometric head of up to 8 mwc Max. operating pressure bar Min. suction pressure, bar at 9 C Temperature range - C at 9 C Max. ambient temperature + C EEI-Part,
More informationINISOL EASYLIFE. SOLAR COLLECTORS, TANKS AND SYSTEMS for domestic installations
INIOL OLAR COLLECTOR, TANK AND YTEM for domestic installations INIOL NEO solar collector and fields of solar collectors INIOL UNO/1 and UNO/2 solar tanks for the production of domestic hot water (200 to
More informationZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS
ZENA PLUS WALL-HUNG GAS BOILERS MSL FF: from. to 1 kw for heating only MSL FF + BMR 80 and MSL FF + SR 10: from. to 1 kw for heating and DHW produced by an 80-litre calorifier placed beside the boiler,
More informationRemeha. Fuel oil/gas boilers P 320. Installation and Service Manual
Remeha Fuel oil/gas boilers P 320 en Installation and Service Manual 300016243-02 Declaration of conformity The appliance complies with the standard model described in declaration of compliance. It is
More informationDIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe
DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe Copyright 206 Caleffi NA0322.02 www.caleffi.com NA5453 Series Installation, commissioning and servicing instructions Function
More informationRADIANT PANEL SYSTEM CONTROL QUICK GUIDE
RADIANT PANEL CONTROL QUICK GUIDE 05 RADIANT PANEL CONTROL Terms and definitions The system temperature regulation can be carried out in only two basic ways: Flow rate control of the medium feeding the
More informationTelo Shower Mixing Valve TL10016CP
Telo Shower Mixing Valve TL10016CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept any responsibility
More informationAPPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation
OPERATING RANGE Flow rate of up to m /h Manometric head of up to m Max. operating pressure bar Min. intake pressure, bar at 9 C Water temperature range + at + C * EEI-Part, * for a ambient temperature
More information4FLOOR-STANDING GAS CONDENSING BOILERS
EASYLIFE PROJECT / SOLNEO / ECODENS RESIDENTIAL DTG (E) 130-15/25 Eco. NOx Plus DTG (E) 1300-15/25 Eco. NOx Plus/B150 DTG (E) 1300-15/25 Eco. NOx Plus/H150 DTG 1300-15/25 Eco. NOx Plus/V130 4FLOOR-STANDING
More informationCommissioning a Solar Thermal Installation
OPERATING INSTRUCTIONS Wagner& Co Commissioning a Solar Thermal Installation Contents. Solar Circuit... 2. Commissioning... 3 3. Service Information... 4. Maintenance.... Solar Circuit Components Pipework
More informationVIESMANN. Installation and service instructions. Solar-Divicon SR. Safety instructions. Application. for contractors. Part no and
Installation and service instructions for contractors VIESMANN Solar-Divicon SR Part no. 7419 520 and 7419 521 Safety instructions Please follow these safety instructions closely to prevent accidents and
More informationCondair Esco. Steam humidification system INSTALLATION INSTRUCTIONS EN 1310
Condair Esco Steam humidification system L INSTALLATION INSTRUCTIONS 1117775 EN 1310 3 Contents 1 Introduction 4 1.1 General 4 1.2 Safety 4 2 Esco DL40 5 2.1 Overview Esco DL40 5 2.2 Mounting the Esco
More informationINSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE
INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE SPECIFICATIONS... 1 OVERVIEW... 2 PRECAUTIONS... 2 MOUNTING LOCATION... 2 CONNECTION TO BOILER PRIMARY PIPING:... 3 ELECTRICAL CONNECTION... 4 FLUSHING THE
More informationINSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20
INSTALLATION, OPERATION AND MAINTENANCE Ariterm Hybrid 20 TABLE OF CONTENTS General...3 Installation... 4-5 Dimensions - with flue gas exhauster...6 Dimensions - without flue gas exhauster...7 Pipe installations...8
More informationEXTREME 2 Reverse Osmosis System
EXTREME 2 Reverse Osmosis System Leader Evaporator Co., Inc. 49 Jonergin Drive Swanton, VT 05488 Tel: 802-868-5444 www.leaderevaporator.com TABLE OF CONTENTS INTRODUCTION... 4 THEORY OF OPERATION... 4
More informationSpectrum TM. Installation, Service & Operation Manual O FLO. SoftH 2. Water Softener. Table of Contents
Installation, Service & Operation Manual SoftH 2 O FLO Water Softener Table of Contents 1. Description & Equipment Adjustments p.2 2. Components, Features & Functions p.3 3. Valve User Interface p.4 4.
More informationOperating instructions
BA60500GB.docx, Operating instructions -Translation of the original- Dirt Collecting Filter DIN m/m M&S Article No. 60500 M & S Armaturen GmbH Industriestraße 24-26 - 26446 Friedeburg - Germany fon +49(0)4465
More informationCold water HD 9/18-4 ST
Cold water HD 9/18-4 ST The space-saving stationary high-pressure cleaners from Kärcher with up to 6 supply points can be individually configured according to requirements and impress with low wear and
More informationT E C H C A L EBS-1 T High technology heating
IMPORTANT FOLLOW COMMISSIONING INSTRUCTIONS OBSERVE THE WARRANTY CONDITIONS READ THE WHOLE MANUAL CAREFULLY NO SAFETY DISCHARGE TO BE REDUCED IN SIZE. CONDENSE TO BE 32 mm PVC T E C H NI C A L I N ST EBS-1
More informationBeautifully Traditional
TECHNICAL DETAILS For full technical details on all our products, please visit our website Arcade bath shower mixer - deck mounted with brass handle handset Arcade bath shower mixer - wall mounted with
More informationVAILLANT SPARE PART CATALOGUE
VAILLANT SPARE PART CATALOGUE Vaillant unvented indirect hot water cylinder VANTAGE VIHC120 VANTAGE 120 VANTAGE 150, 200 Vaillant gas fired storage water heater VGH 130/1, 160/1, 190/1 VGH 130/2, 160/2,
More informationDTG Eco / V130
ECODENS Gas fired condensing boiler EN User Guide 300010111-001-B Contents 1 Introduction.............................................................................3 1.1 Symbols and abbreviations................................................................................3
More informationSTREBEL S-CB + Cascade Kits
STREBEL S-CB + Cascade Kits Models + 60 - + 80 - + 100 - + 120 PX 120 - + 10 - + 180 Installation & Operating Manual 2x60 up to 12x180 Please read and understand before commencing installation and leave
More informationHR Powder Feed Hopper
Instruction Sheet P/N 106977E0 Description This instruction sheet provides specifications; installation and operation instructions; and parts lists for the HR-16-150 powder feed hopper. The hopper is shipped
More informationVIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A
Installation instructions for contractors VIESMNN Vitocell 300-V/W Type EVI- DHW cylinder with internal indirect coil 160 to 500 l VITOCELL 300-V/W 3/2017 Dispose after installation. Safety instructions
More informationInstallation Manual. Conergy TS Open and Closed Systems.
Installation Manual Conergy TS Open and Closed Systems www.conergy.com.au Table of Contents Table of Contents 1 1.1 Installer Information The environmental benefits 2 2 1.2 Why Conergy? 2 1.3 How does
More informationInstallation, commissioning and servicing instructions
NA10322.01 www.caleffi.com DIRTMAG dirt separator Copyright 2015 Caleffi NA5453 Series Installation, commissioning and servicing instructions Function In heating and chilled water systems, the circulation
More informationVERTINOX. AISI 316 stainless steel accumulators with one or two heat exchangers, fixed or removable type
27-0514 VERTINOX AISI 316 stainless steel accumulators with one or two heat exchangers, fixed or removable type VERTINOX: THE RELIABLE HEART The boiler for hot sanitary water production is the heart of
More informationLago SD3. Differential Controller with Speed Control. Operating and Installation Instructions
Lago SD3 Differential Controller with Speed Control Operating and Installation Instructions Please observe the safety instructions and read through this manual carefully before commissioning the equipment.
More informationAD XT. Air Dryer Service Manual. Innovation with Integrity. Version 003 NMR
AD XT Air Dryer Service Manual Version 003 Innovation with Integrity NMR Copyright by Bruker Corporation All rights reserved. No part of this publication may be reproduced, stored in a retrieval system,
More informationInstruction Manual. Automatic fuel oil de-aerator SMART-FLO 3/K B100 COMPATIBLE
Sid Harvey s 605 Locust Street Garden City, NY 11530 Instruction Manual Automatic fuel oil de-aerator SMART-FLO 3/K Read manual before use! Observe all safety information! Keep manual for future use! 05.2015
More informationThermostatic Concealed Shower Valve
Thermostatic Concealed Shower Valve Product may differ from image. Please retain this booklet for future aftercare reference Component Breakdown - Three Handle Valve Component breakdown Two Handle Valve
More informationPump assembly Instruction manual
Instruction manual EN Version 2.0 /Release 06/2012 Table of content 1 Key background information...3 1.1 Limitation of liability...3 1.2 Responsibilities of the operator...3 1.3 Documentation...3 1.3.1
More informationInstallation, operation and maintenance. Accumulator tank. Acc-tank 500 CU. Acc-tank 500 UB ver: Supersedes:
Installation, operation and maintenance Accumulator tank Acc-tank 500 CU 2010-11-2 ver: Supersedes: Acc-tank General information 1011 Read through these instructions carefully before carrying out installation,
More informationEXTREME 4 Reverse Osmosis System
EXTREME 4 Reverse Osmosis System Leader Evaporator Co., Inc. 49 Jonergin Drive Swanton, VT 05488 Tel: 802-868-5444 www.leaderevaporator.com TABLE OF CONTENTS INTRODUCTION... 4 THEORY OF OPERATION... 4
More informationFlat Plate Solar Collector
Flat Plate Solar Collector Installation, commissioning and maintenance instructions Models: LSP20+ LSP20+H installation manual_flat plate collector_augus t2017 Page 0 CONTENTS 0 1 INTRODUCTION... 3 1.1
More informationHIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler
HIGH POWER VICTRIX PRO 2 ErP High power, wall-hung condensation boiler MAIN INDEX INDEX 1 VICTRIX PRO 35-55 2 ErP SPECIFICATIONS...5 2 VICTRIX PRO 80-100-120 2 ErP SPECIFICATIONS...6 3 VICTRIX PRO 35-55
More informationPARTS BOOK. From S/N:
PARTS BOOK From S/N: 2786017 All spares available from The Engine Shed Top Station Road Brackley NN1 7UG Tel: 0845 108060 Fax: 01280 84545 Web: www.caterparts.com Copyright Notice: All rights reserved.
More informationBrazed heat exchanger XB
Description The XB is a range of copper brazed plate heat exchangers for use in District Heating (DH) and District Cooling (DC) applications, e.g. domestic hot water production, district heating substation
More information