1 INSTALLATION AND INSTRUCTION MANUAL SOLAR STATION Installation and instruction manual SOLAR STATION SST 25-1E / SST25-2E EN April

2 Table of contents Usage 3 Warranty 3 Safety instructions and symbol legend 3 Safety instructions 3 Symbol legend 4 Scope of delivery 4 Provisions 5 Statutory provisions 5 Manufacturer s specifi cations 5 Pumping medium 5 Technical data 5 Technical data SST25-2E 5 Technical data SST25-1E 6 Connection and performance data SST25-2E / SST25-1E 7 Installation 8 Installation on buffer tank 8 Connection of solar fl ow an return fl ow 9 Wall fastening SST25-2E 10 Wall fastening SST25-1E 11 Hydraulic installation 12 Electric connection 12 Standard operating mode 12 Functioning 13 Gravity brake 13 Operating position 13 Emptying/fi lling position 13 Closed position 13 Flow meter 14 Initiation 15 Filling 15 Rinsing 15 Bleeding 15 Service 16 Control rinsing 16 Control rinsing step 1 16 Control rinsing step 2 16 Appendix 17 Safety precautions for the operator 17 Pump 19 Pump Curve 20 Technical Data - Wilo Yonos Para 21 Notes 22 2

3 INSTALLATION AND INSTRUCTION MANUAL SOLAR STATION Usage The solar station SST25 is used to connect solar thermal collectors to a buffer or a hot water tank. It will be installed next to the buffer or hot water tank at the wall or directly onto the tank at special system solutions. Another use or installation is not intended. The manufacturer is not liable for damages due to inappropriate use and the operator bears the risk. The solar station is factory-equipped with a two-circuit controller. The controller measures the collector and tank temperatures with Pt1000 sensors and regulates based on that data the buffer or hot water tank temperature respectively. Warranty The Manufacturer issues a warranty of 2 years from the invoice date on the device and its constituent parts. Without proper installation and use of the device the warranty is void. Safety instructions and symbol legend Safety instructions The installation, initiation and maintenance must only be accomplished by qualifi ed technical professionals. The operation of this device is not allowed to persons (including children) with limited physical, sensory or intellectual abilities. Uninformed or unacquainted persons may operate the device only under the supervision or at a trained person s disposition. Replacements or repairing of electrical parts like the power cord must be conducted by a professional electrician. Follow the instructions in this manual closely to ensure proper functioning. Exclusively use the solar station in a solar thermal system. Fuses, wiring and earthing must be installed according to regional regulations. The electric connection needs to be realized with the provided power cord. The solar controller must be protected from overvoltage-induced damages. The solar controller must only be opened in case of a service. Make sure to disconnect the device from power supply prior to open the housing. Only install the device in dry and frost-free locations. Operate the device only at ambient temperatures between +2 C and +40 C. Interrupt the power supply of the system (230 V/AC) prior to installation. During operation the device can heat up and burns are possible. The device must be connected to an external circuit breaker to allow a shutdown at any time. Installation and operation must be performed according to regional laws, regulations and common practice. At the occurrence of malfunctions regardless of nature please contact your authorized technical professional. 3

4 Symbol legend Safety instructions are marked with a warning triangle as illustrated on the right. Safety instructions indicate important information for potentially dangerous situations for person and device. Additional buzzwords describe nature and severity of the danger. Advices are marked with an information sign as illustrated on the right. Advices highlight important information for situations without severe danger for person and device. Screw wrench indicates the maximum tightening torque [Nm] and the rotational direction. max. tightening torque [Nm] Scope of delivery Solar Station Mounting set SST25-2E Accessory kit sensor set SST25-1E SST25-1E SST25-2E Connenction set SST25-1E SST25-2E Sensor set SST25-1E SST25-2E 4

5 INSTALLATION AND INSTRUCTION MANUAL SOLAR STATION Provisions The device must be installed and operated according to the following norms and country specifi c directives and provisions. DIN 4751 DIN 4757 DIN DIN DIN DIN EN DIN EN VDE 0100 VDE 0185 VDE 0190 ÖNORM ENV ÖNORM M7701 ÖNORM M7731 Manufacturer s specifications Pumping medium Water and water-/glycol-mixes in mixing ratios up to 1:1. Due to admixing of glycol, the pump characteristic lines need to be adjusted according to the increased viscosity (depending on the mixing ratio). Only use dedicated pumping mediums with anticorrosive inhibitors Technical data SST25-2E 1 A 1 B E F 1 Ball valves with integrated gravity brake 2 Manometer 3 Solar safety valve (6 bar) 4 Charging pump 5 Flow meter 1-13 l/min with rinsing / shut-off function 6 Air-jet Manual bleeding nipple 8 KFE-Valve Dial thermometer 10 Controller 5 14 Hose nozzle for KFE Valve Connections: 14 A Collector feed C D B C Collector return Tank feed D Tank return E Membrane expansion vessel F Collecting vessel 5

6 Technical Data SST25/1 E B F 8 E D 1 Ball valve with integrated gravity brake 2 Manometer 3 Solar safety valve (6 bar) 4 Charging pump 5 Flow meter 8 KFE-Valve 9 Dial thermometer 10 Controller 11 Safety spring 12 Mounting plate 13 Insulation 14 Hose nozzle for KFE-Valve Connections B Collector return D Tank return E Membrane expansion vessel F Collecting vessel 6

7 INSTALLATION AND INSTRUCTION MANUAL SOLAR STATION Solar Station SST25-1E SST25-2E Max. collector area [m 2 ] 25 m² 25 m² Controller STRG Omega 1 1-circuit-controller Charging pump [V/Hz] Wilo Yonos Para 15/7.0 PWR Power input [W] 3-45 STRG Omega 2-circuit-controller Temperatures[ C] Ambience 2-40 Buffer-/Boiler-water max. 95 Feed 140 Return 120 Max. operating pressure [bar] 6 Medium Water with max. 40% propylene-glycol Dimensions [mm] Width Height Depth Connections Collector Rp¾" IG Rp¾" IG Tank G1" AG G1" AG Expansion vessel G¾" AG Nominal width DN 15 Insulation EPP Weight [kg] 6,8 8,5 Connection- and performance data Minimum feed-pressure at intake* at temperature + 50 C: at temperature + 95 C: at temperature +110 C: 0,05 bar 0,3 bar 1,0 bar Permitted temperature range: -10 C bis +140 C Maximum ambiance temperature: +40 C * These values are valid for regions up to 300 meters above sea level. Additional pressure for higher altitudes: 0,01 bar per 100 meters. To avoid cavitation noises, maintain the minimum feed-pressure at pump intake. 7

8 Installation Installation on buffer tank 1 3 Pre-assembly of cleats Installation of connection-set 2 4 Installation onto buffer tank Installation of piping 8

9 INSTALLATION AND INSTRUCTION MANUAL SOLAR STATION 5 6 Installation of sensors Final assembly max. 70Nm A 1.2 Connection of solar flow and return lines CAUTION! To tighten union nuts SW32 of the clamping ring connections: Rotate the handles of the ball valves to the closed position (slots stand horizontally) on the solar fl ow and return ball valve ( ). Use an open-ended spanner SW36 (A) to fasten clamping ring connection above ball valves. Use an open-ended spanner SW36 (B) to exert counterpressure on the nuts beneath the ball valves. Finally rotate the ball valves to the open position. 1.1 B 9

10 359, Wall fastening SST25-2E Pre-assembly of cleats Drilling plan 2 max. 10 Nm S12 12 mm Ø12 60 min Installation onto wall 10

11 INSTALLATION AND INSTRUCTION MANUAL SOLAR STATION Wall fastening SST25-1E Pull return fl ow line out of mounting plate. Mark fastening point of mounting plate on the wall and drill two holes ø10 mm. (see picture) Set dowels and screw mounting plate tightly with screws and fl at washers. Adjust mounting plate horizontally. Slide back insulations cover on mounting plate. Check if molded springs are fi tted correctly in the mounting plates hulls. Slide the back cover over the hull, push return fl ow line on pin of ball valve until it latches 11

12 Hydraulic installation 3 Caution! The emergent pumping medium at the solar relief valve must be drained over a suitable pipe into a drain bottle. 2 Manometer (measurement range 10 bar) 3 Solar safety valve (6 bar) 8 KFE-Valve 8.1 Covering cap KFE-Valve E Pipe union for membrane expansion vessel F Connection drain bottle Electric connection Safety unit F E Caution! Do not bend the cable sharply and do not lay it while energized! Do not run the cable directly over sharp-edged components. The installed cables must not touch the pipes and/or the pump. Connection schemes for sensors, pumps and actuators: see manual of controller Controller 10.1 Faceplate screw Controller Pump cables and mains cables are attached to the solar controller at the factory. The terminals for the sensors can be accessed after loosening the screw (10.1) on the controller s faceplate (10). Standard operating mode Nr. Name Position Status 5.1 Spindle Flattening downwards Operation 1.1 Ball valve 0 Open incl. gravity brake 1.2 Ball valve 0 Open incl. gravity brake 8.1 KFE-Valve Vertical Closed 8.2 KFE-Valve Vertical Closed Standard operating mode

13 INSTALLATION AND INSTRUCTION MANUAL SOLAR STATION Functioning Gravity brake The gravity brakes are built into the feed and return ball valve. They are operated by turning the ball valve handle. Operating position Handle position: 0 The valve discs must not be opened, to prevent circulation under the force of gravity. The gravity brakes are closed and the ball valves are opened. Operating position Emptying/filling position Handle position: 45 The gravity brakes and ball valves are opened Emptying/fi lling position Closed position Handle position: 90 The ball valves are closed. Closed position 13

14 Flow meter Adjusting the fl ow rate of the pumping medium is achieved by selecting the RPM setting on the circulation pump (4) and with the throttle on the fl ow meter (5.1). The fl ow meter displays the fl ow rate. The range is between 1 and 13 l/min. Read the fl ow rate from the upper edge of the fl oat (5.2) Flow meter

15 INSTALLATION AND INSTRUCTION MANUAL SOLAR STATION Initiation Prior to fi lling and rinsing the solar system, unscrew the caps from the closed KFE-Valves and connect the feed pipes to the fi lling and rinsing devices Adhere to sequence (SEQ)! In the following tables, the exact sequence is indicated in the column SEQ Filling SEQ Nr. Name Position Status Ball valves incl. gravity brake 45 Open Ball valves incl. gravity brake 45 Open Spindle Flattening downwards Passage KFE-Valve Horizontal Open KFE-Valve Horizontal Open 8.2 Filling of solar station 5.1 Rinsing If a rinsing process with opposite rinsing direction is necessary, it is advisable to conduct a fi nal control rinsing (see page 16 chapter control rinsing). SEQ Nr. Name Position Status Ball valves incl. gravity brake 45 Open Ball valves incl. gravity brake 45 Open Spindle Flattening left (S) Rinsing KFE-Valve Horizontal Open KFE-Valve Horizontal Open Rinsing Bleeding Caution danger of scalding! Bleeding may only be carried out by trained technical personnel. Depending on the temperature of the pumping medium and the system pressure, the hot medium can discharge fl uid or gaseous and with high pressure. Uncontrolled bleeding leads to a pressure loss and to malfunctions in the solar system. The Air-Jet (5) collects the remaining air in the pumping medium and that air can be discharged manually via the bleeding nipple (7). To discharge the air, push the provided hose onto the nozzle (7.1) on the nipple and catch any fl uid in a suitable container. Concluding, close bleeding nipple tightly and check system pressure. If necessary, refi ll the system with the needed amount of pumping fl uid Bleeding

16 Service Caution danger of burns! The pump may get very hot in various operational stages (e.g. due to the pumping medium). Adhere to sequence (SEQ)! Prior to opening the KFE-Valve (8.2), turn valves (1.1), (1.2), (8.1) and spindle (5.1)into the following positions SEQ Nr. Name Position Status Ball valve 90 Closed incl. gravity brake Ball valve incl. gravity brake 90 Closed Spindle Flattening right (E) Service KFE-Valve Vertical Closed KFE-Valve Horizontal Open The pumping medium can be drained by out of the pump by opening the KFE-Valve (8.2) Control rinsing A fi nal control rinsing happens in two steps. Control rinsing, step 1 SEQ Nr. Name Position Status Spindle Flattening left (S) Rinsing Ball valve 0 Open incl. gravity brake Ball valve 45 Open incl. gravity brake KFE-Valve Horizontal Open KFE-Valve Horizontal Open Close KFE-Valves (8.1) and (8.2) after rinsing Control rinsing, step SEQ Nr. Name Position Status Spindle Flattening right (E) Service Ball valve 90 Closed incl. gravity brake Ball valve 0 Open incl. gravity brake KFE-Valve Horizontal Open KFE-Valve Horizontal Open Close KFE-Valves (8.1) and (8.2) after rinsing

17 INSTALLATION AND INSTRUCTION MANUAL SOLAR STATION Safety precautions for the operator General: Installation and service by qualifi ed personnel only Fields of application: Type: ST: for solar thermal systems Connection and output data: Minimum input pressure at the air intake* at temperatures +50 C: 0,05 bar at temperatures +95 C: 0,3 bar at temperatures +110 C: 1,0 bar Permissible temperature range: -10 C bis +140 C Max. permissible ambient temperature: +40 C * These values are valid up to 300 m above sea level. For higher elevations add: 0,01 bar / 100 m. The minimum inlet pressure must be maintained in order to avoid cavitation noise. Permissible fluids: Water and water/glycol mixtures up to a ratio of 1:1. Glycol mixtures require a reassessment of pump hydraulic data in line with the increased viscosity and depending on mixing ratios. Only approved marks of additives with corrosion inhibitors must be used instrict compliance with manufacturers instructions. Safety Rules Safety Rules For The Operator Local regulations for the prevention of accidents must be observed. Danger from electrical energy must be excluded (conforming to local or general regulations such as IEC, VDE, etc.) Safety Rules for Inspections and Installation Work It is the operator s responsibility to ensure that inspections and installation work are carried out by authorized and qualifi ed personnel only, having themselves made fully conversant with these instructions. Work must principally be carried out only with the plant switched off and at complete standstill. Abnormal Operating Conditions Operational safety of the plant is only ensured if used in accordance with these instructions. The limits stated there must not be exceeded under any circumstances. Description of Product and Accessories The pump YONOS PARA is a solar thermal pump with special hydraulic (pumphousing coated) for using in solar thermal systems. Motor overload protection is not required. The motor operates non-overloading. Sitting/Installation Installation Direction of fl uid fl ow must correspond with the arrow on the pump housing. When connecting the pump to the conduit of pipes, the pump can be secured against twisting using a spanner on the key surfaces which have been created for this purpose. 17

18 Electrical wiring: Cable leads to be routed in such a way to avoid any contact with pipe work and/or pump or stator housings. Check that the mains current and voltage comply with the data on the rating plate. Pump/installation must be earthed in compliance with regulations. Commissioning System filling and venting The pump is normally vented automatically after a short operational period. Danger of scalding exists! The pump can become extremely hot, depending on the operational state of the pump or the pipe system (fl uid temperature) Danger of scalding exists when touching the pump! 18

19 INSTALLATION AND INSTRUCTION MANUAL SOLAR STATION Charging pump Danger of scalding exists!! The pump can become extremely hot, depending on the operational state of the pump or the pipe system (fluid temperature). Function PWM The PWM-signal is used for RPM Controlling and therefore the power of the charging pump Declaration of conformity Wilo Yonos Para 19

20 Performance curves Pressure loss: (bar) Pressure loss curve SST25-2E Volume: (m3/h) 20

21 INSTALLATION AND INSTRUCTION MANUAL SOLAR STATION Technical Data - Wilo Yonos Para Technical Data Yonos PARA 15 / 7.0 PWR Approved fluids (other fluids on request) Heating water (in accordance with VDI 2035) Water - Glycol - Mixtures (max. 1:1; above 20% admixture, the pumping data must be checked) Power Energy Effi ciency Index (EEI) ± 0,2 Max. delivery head (Hmax) 7.3 m Max. volume fl ow (Qmax) 3.3 m 3 /h Permitted field of application Temperature range at max. ambient temperature von 55 C = 0 bis 110 C von 62 C = 0 bis 90 C von 66 C = 0 bis 80 C von 71 C = 0 bis 70 C Maximaler operating pressure 10 bar Electrical connection Mains connection 1~230 V, 50/60 Hz Motor/Electronics Electromagnetic compatibilty EN Emitted interference EN EN Interference resistance EN EN Speed Control Frequency converter Protection class IP X4D Insulation class F Minimum suction head at suction port for avoiding cavitation at water pumping temperature minimum suction head at 50 / 95 / 110 C 0.5 / 4.5 / 11 m 21

22 Notes 22

23 INSTALLATION AND INSTRUCTION MANUAL SOLAR STATION Notes 23

24 Contact: 24

Fresh Water Station FWS 20 / FWS 30. Manual. Masterpieces. Art.-Nr.: (V1.0) of Solar Technology

Fresh Water Station FWS 20 / FWS 30. Manual. Masterpieces. Art.-Nr.: (V1.0) of Solar Technology Fresh Water Station FWS 20 / FWS 30 Manual Masterpieces of Solar Technology Art.-Nr.: 700096 (V1.0) Table of content 1 Preface 3 1.1 Usage 3 1.1.1 Usage example Fresh Water Station 4 1.1.2 Usage example

More information

Buffer Tank FWSS 1000 V7-RH

Buffer Tank FWSS 1000 V7-RH Buffer Tank FWSS 1000 V7-RH Manual Art.-Nr.: 700119 (V1.0) Table of content 1. Preface 3 1.1 Usage 3 1.1.1 Usage example Fresh Water Station 3 2. Description 4 3. Warning notices 4 4. Design of the Fresh

More information

Domestic Hot Water Tank

Domestic Hot Water Tank Installation and Operating Manual Domestic Hot Water Tank WWKS 300 WWKS 500 EN For the professionals Read carefully before installation Table of Contents 1 Use............................. 3 2 Safety Instructions

More information

CIRCO 6 Solar Circulation Unit

CIRCO 6 Solar Circulation Unit TECHNICAL INFORMATION / INSTALLATION INSTRUCTIONS CIRCO Solar Circulation Unit CIRCO Solar Circulation Unit in combination with the intelligent SUNGO controllers, it is the safe and reliable heart of a

More information

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100 1 Safety instructions Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead

More information

Solar station DKP 6-8 / DKP Installation and Service Manual C

Solar station DKP 6-8 / DKP Installation and Service Manual C EN Solar station DKP 6-8 / DKP 9-20 Installation and Service Manual 300014274-001-C Contents 1 Introduction.............................................................................3 1.1 Used symbols...........................................................................................3

More information

Manual SLM50HE.

Manual SLM50HE. Manual SLM50HE www.sonnenkraft.com www.sonnenkraft.com Table of Contents 1. General 3 1.1. Use 3 1.2. Application example 3 2. Description 4 3. Warning 4 4. Structure of the shift layer module 4 5. Safety

More information

EN Z Subject to change due to technical improvements! Operating instructions

EN Z Subject to change due to technical improvements! Operating instructions SOLARTHERMIE - SOLAR THERMAL - SOLAR TÉRMICO - SOLAIRE THERMIQUE Operating instructions Temperature differential controller 3 inputs, 1 output These operating instructions are part of the product. Read

More information

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25 PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and operation instructions Solar stations SolarBloC

More information

Manual and installation instructions. Function. Operating phase

Manual and installation instructions. Function. Operating phase LADDOMAT M120 Manual and installation instructions Thermal layering Function Thanks to its design and control features, the Laddomat M120 means optimal thermal layering in storage tanks, with a low and

More information

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE INSTRUCTION MANUAL INSTALLATION AND SERVICING AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE About this manual These installation and maintenance instructions contain important information

More information

Friwa Compact. Operating instructions EN

Friwa Compact. Operating instructions EN Operating instructions EN Version 1.1 / Edition 09/2013 Contents 1 Key background information... 3 1.1 Limitation of liability... 3 1.2 Responsibilities of the operator... 3 1.3 Documentation... 3 1.3.1

More information

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions Electronically controlled instantaneous water heater MCX: 27300, 27400 and 27600 models Installation instructions These appliances deliver water not exceeding 50 ºC in accordance with AS3498. 1. Overview

More information

1 Declaration of conformity

1 Declaration of conformity ENERGY SAVING 1 Declaration of conformity We Taco Italia S.r.l. declare under our sole responsibility that the family of products ENERGY SAVING to which this declaration relates are in conformity with

More information

3-way switching valve

3-way switching valve Operating Manual UK 3-way switching valve for domestic hot water charging USV 1" AG USV 5/4" AG USV 6/4" IG UK805189 / 201109 Translation of the original instruction manual Please read first This operating

More information

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l Installation instructions for contractors VIESMANN Vitocell 300-B Type EVBA-A Dual mode DHW cylinder, 300 and 500 l VITOCELL 300-B 1/2017 Dispose after installation. Safety instructions Please follow these

More information

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use 1 Safety instructions 1.1 Proper use Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN 100 Any improper use, intervention in the design and deviation from the design data automatically

More information

DEVIATING VALVES ART K063

DEVIATING VALVES ART K063 FUNCTION The flow diverter valve Art.307 makes it possible to supply a branch circuit. Prepared to receive our electro-thermal controls Art. 978, 979, 980 or our thermostatic heads with remote sensor Art.

More information

1592P01. for liquids in piping DN

1592P01. for liquids in piping DN 1 594 1592P01 Flow switch for liquids in piping DN 20 200. QVE1901 Contact load / switching capacity: max. AC 230 V, 1 A, 26 VA max. DC 48 V, 1 A, 20 W Nominal pressure PN25 Manual setting of contact type

More information

ASSEMBLY INSTRUCTIONS FOR THE PUMP AND CONTROL UNIT ZPS 18a-01

ASSEMBLY INSTRUCTIONS FOR THE PUMP AND CONTROL UNIT ZPS 18a-01 ASSEMBLY INSTRUCTIONS FOR THE PUMP AND CONTROL UNIT ZPS 18a-01 1. Use and construction of the pump and control unit The pump and control unit is designed to work with solar collectors in systems with required

More information

FSW300 Series Flow Switch

FSW300 Series Flow Switch . FSW300 Series Flow Switch - 2 - Series FSW300 Series FSW300 Table of contents page 0 About this operating manual... 4 1 Device description... 5 1.1 Intended use... 5 1.1.1 Reed contact - Switching of

More information

The Meibes concept for the specialist: Easier. Quicker. More successful.

The Meibes concept for the specialist: Easier. Quicker. More successful. P R I C E L I S T 3 5 V A L I D F R O M 0 1. 0 1. 2 0 1 0...for the professional installer The Meibes concept for the specialist: Easier. Quicker. More successful. Easier Complete pre-assembled modules

More information

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40 1 Safety instructions Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically

More information

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W 594 59P0 Flow switch for liquids in piping DN 0 00. QE90 Contact load / switching capacity: Nominal pressure PN5 Manual setting of contact type (NO / NC) Housing IP 65 / safety class II Maintenance free

More information

Laboport Chemically-resistant Laboratory Pumps and Systems

Laboport Chemically-resistant Laboratory Pumps and Systems Operating Instructions Read and observe these Operating Instructions! Laboport Chemically-resistant Laboratory Pumps and Systems N 810 FT.18 N 820 FT.18 N 840 FT.18 N 840.1.2 FT.18 N 810.3 FT.18 N 820.3

More information

NON-SUBMERSIBLE WATER PUMP

NON-SUBMERSIBLE WATER PUMP NON-SUBMERSIBLE WATER PUMP MODEL NO: CEB103 PART NO: 7230327 OPERATION & MAINTENANCE INSTRUCTIONS LS0114 INTRODUCTION Thank you for purchasing this CLARKE Water Pump, which is a general purpose pump, suitable

More information

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions Electronically controlled instantaneous water heater CEX 9-U: 27910-50 C models Installation instructions For 50 ºC models, the appliance delivers water not exceeding 50 ºC in accordance with AS3498. 1.

More information

VERSAFLOW VORTEX Supplementary instructions

VERSAFLOW VORTEX Supplementary instructions VERSAFLOW VORTEX Supplementary instructions Vortex flowmeter Equipment category II 2G CONTENTS VERSAFLOW VORTEX 1 Safety instructions 3 1.1 General notes... 3 1.2 EC conformity... 3 1.3 Approval according

More information

Control valves for floor heating systems. Floor Heating Manifolds

Control valves for floor heating systems. Floor Heating Manifolds Control valves for floor heating systems Floor Heating Manifolds IMI HEIMEIER / Floor Heating Control / Control valves for floor heating systems Control valves for floor heating systems Supply control

More information

HKF 8180 Operating instructions

HKF 8180 Operating instructions Operating instructions EN Version 1.0en /Edition 05/2013 Contents 1 Important basic information... 3 1.1 Limitation of liability... 3 1.2 Operator's responsibilities... 3 1.3 Documentation... 3 1.3.1 Content

More information

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card SOLARTHERMIE - SOLAR THERMAL - SOLAR TÉRMICO - SOLAIRE THERMIQUE - SOLARE TERMICO Installation and operating instructions Temperature difference controller 6 inputs, 3 outputs, integrated data logger for

More information

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2 Cleaning unit for coolant :_decftez`_>r_fr] Book No.: 1271526-02 V2 Alfa Laval Separation AB Separator Manuals, dept. SKEL S-147 80 Tumba, Sweden Telephone: +46 8 53 06 50 00 Telefax: +46 8 53 03 10 40

More information

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO AOYG8LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL For authorized service personnel only. English PART NO. 93778639 93778639_IM.indb /20/20 6:07:25 PM AIR CONDITIONER OUTDOOR UNIT INSTALLATION

More information

PV3000S Professional Pond Vacuum

PV3000S Professional Pond Vacuum PV3000S Professional Pond Vacuum INSTRUCTION MANUAL PV3000S Professional Pond Vacuum PV3000S POWER CONSUMPTION POWER SUPPLY NOMINAL CURRENT POWER CABLE LENGTH MAX PUMPING CAPACITY MAX PUMPING HEAD AUTOMATIC

More information

Lifting Station Type ABS Sanimax

Lifting Station Type ABS Sanimax 1051-00 15970278EN (11/2015) EN Installation and Operating Instructions www.sulzer.com 2 Installation and Operating Instructions (Original Instructions) : R 202 MF 154 R 202/C MF 154HW MF 324 Contents

More information

Operating instructions

Operating instructions SOLARTHERMIE - SOLAR THERMAL - SOLAR TÉRMICO - SOLAIRE THERMIQUE Operating instructions Temperature Differential Controller inputs, 1 output These operating instructions are part of the product. US Read

More information

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL CONTENT 3 Introduction 3 General 3 Safety rules 3 Storage and transportation rules 3 Manufacturer s warranty 4 Fan design 4 Delivery set 5 Technical data

More information

General System Layout Sketch

General System Layout Sketch General System Layout Sketch EZ-37 Solar Panels PV panel Glycol Fill Valve Expansion Tank ` 1 Introduction This document describes how to install a Heliatos GH type solar water heating system. These systems

More information

Installation, operating and servicing instructions

Installation, operating and servicing instructions English 57-115 - 144-1 - 259 Installation, operating and servicing instructions ITALIA EN 1 ITALIA English INDEX WARnINGS 3 Who should read these instructions 3 Symbols 3 Recommendations 3 Importants notes

More information

HELIATOS Bottom Feed Connector Installation Instructions Introduction. Step 1

HELIATOS Bottom Feed Connector Installation Instructions Introduction. Step 1 Introduction The Bottom Feed solar water heater connector is meant to connect solar water heater panels directly to your existing standard water heater. It's main advantages are ease of installation, efficiency,

More information

Acquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11. CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2

Acquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11. CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2 CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2 Congratulations on your purchase of a LEO Centrifugal Pump It is important that you read, fully understand and observe the following

More information

Closomat Lima Vita installation & user guide

Closomat Lima Vita installation & user guide Closomat Lima Vita installation & user guide design manufacture supply install service recycle Technical data The Closomat toilet MUST be installed by a competent or qualified person. Explanation of symbols

More information

GENERAL INFORMATION CONTENTS

GENERAL INFORMATION CONTENTS AMTCM4H4R18 In line with the company s policy of continual product improvement, the aesthetic and dimensional characteristics, technical data and accessories of this appliance may be changed without notice.

More information

Mikrotherm. Manual Radiator Valves With presetting

Mikrotherm. Manual Radiator Valves With presetting Mikrotherm Manual Radiator Valves With presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Mikrotherm Mikrotherm The Mikrotherm manual radiator valve is used in warm water pump heating systems,

More information

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A Millo / Millo pro Nr. 1804-x000 / 1805-x000 0609 21-6543 A Ideen für die Dentaltechnik 1 2 3 4 5 6 7 8 9 10 11 12 Millo / Millo pro No. 1804-x000 / 1805-x000 ENGLISH Content Introduction... 15 Symbols...

More information

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A Installation instructions for contractors VIESMNN Vitocell 300-V/W Type EVI- DHW cylinder with internal indirect coil 160 to 500 l VITOCELL 300-V/W 3/2017 Dispose after installation. Safety instructions

More information

Model: 1100 Float-Controlled Condensate Trap, PN 25

Model: 1100 Float-Controlled Condensate Trap, PN 25 1 Safety instructions Model: 1100 Float-Controlled Condensate Trap, PN 25 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination

More information

Protection and Control of Solid Fuel Boilers

Protection and Control of Solid Fuel Boilers Protection and Control of Solid Fuel Boilers thermal relief valves thermostatic valves and pump stations draft regulators www.regulus.eu BOILER PROTECTION AGAINST OVERHEATING Solid fuel boilers may get

More information

V80-H Multistage Pump Instruction Manual

V80-H Multistage Pump Instruction Manual V80-H Multistage Pump Instruction Manual PRODUCT OVERVIEW The VADA horizontal multistage centrifugal pumps combine the functional benefits of centrifugal pumps and the practical benefits of self priming

More information

SELF-PRIMING JET PUMPS

SELF-PRIMING JET PUMPS SS Anti-Rust SS Shaft Copper & Cold-rolled SELF-PRIMING JET PUMPS CONTENTS 1. Applications.... Model Description.... Technical Data... 4. Implementation Standards... 5. Safety Precautions... 6. Product

More information

AGS 5/5E, AGS 10/10E INSTALLATION AND SERVICING INSTRUCTIONS SOLAR PUMP STATIONS FOR SEALED SOLAR HEATING SYSTEMS AND INDIRECT FED DOMESTIC HOT WATER

AGS 5/5E, AGS 10/10E INSTALLATION AND SERVICING INSTRUCTIONS SOLAR PUMP STATIONS FOR SEALED SOLAR HEATING SYSTEMS AND INDIRECT FED DOMESTIC HOT WATER INSTALLATION AND SERVICING INSTRUCTIONS SOLAR PUMP STATIONS AGS 5/5E, AGS 0/0E FOR SEALED SOLAR HEATING SYSTEMS AND INDIRECT FED DOMESTIC HOT WATER 7747006489.00-.SD CONTENTS CONTENTS Safety instructions

More information

Installation Instructions

Installation Instructions Installation Instructions For Fully Integrated NoFrost Combined Refrigerator-Freezers HCB 1560/1561 7084 429-00 Important Please read and follow these instructions These instructions contain Danger, Warning

More information

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1 A AD Oil burners fuel unit deltapumps.com DE116-0709 A-AD_en_0709.pdf - 16.11.09 Page 1/1 Oil burners fuel unit Type A, AD 1- Applications The DELTA aluminium fuel unit type A is an efficient and modern

More information

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P. 541D19 SERIES Technical Manual A Division of Aquion Partners L.P. Table of Contents Introduction... Page 1 Technical Specifications... Page 2 Flow Diagrams... Page 3 Injector & Flow Control Selection Injector...

More information

12/50 CENTRIFUGAL PUMPS FOR DC SUPPLY OPERATING INSTRUCTIONS

12/50 CENTRIFUGAL PUMPS FOR DC SUPPLY OPERATING INSTRUCTIONS 12/50 CENTRIFUGAL PUMPS FOR DC SUPPLY OPERATING INSTRUCTIONS Please leave this instruction booklet with the pump as it contains maintenance and safety information (Original Instructions) MODELS 12/50 INDEX.................

More information

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

Flow switch.   Operating Manual. English manual page Page 1 of 15 Fax: Operating Manual www.jlso-tec-trade.de Flow switch English manual page 1-15 Page 1 of 15 Flow switch Table of Contents Page 1 Device Description and Intended Use... 19 1.1 Flow switch version VH...X...

More information

Installation and operating instructions. DK energy storage and DK energy buffer

Installation and operating instructions. DK energy storage and DK energy buffer Installation and operating instructions DK energy storage and DK energy buffer Edition: 08-2015 1 Preliminary note With this DK energy storage / DK energy buffer you purchased a DK quality product. The

More information

Technical data. Bathroom/shower room installations. Water services (WRAS approved)

Technical data. Bathroom/shower room installations. Water services (WRAS approved) Technical data The Closomat toilet MUST be installed by a competent or qualified person. Explanation of symbols Safety instructions in this manual are identified by symbols. The safety instructions are

More information

Installation plan: PG 8581 PG Mat. no Version 02 GB, IE, AU, NZ

Installation plan: PG 8581 PG Mat. no Version 02 GB, IE, AU, NZ Installation plan: PG 8581 PG 8583 Mat. no. 10 390 400 Version 02 GB, IE, AU, NZ Technical data sheet Washer-disinfector PG 8581-8583 Legend: Circled, bold-type abbreviations: Connection required Abbreviations

More information

VIESMANN. Service instructions VITOCELL 300-B VITOCELL 300-V. for contractors

VIESMANN. Service instructions VITOCELL 300-B VITOCELL 300-V. for contractors Service instructions for contractors VIESMANN Vitocell 300-B Type EVB DHW cylinder, 300 and 500 l Vitocell 300-V Type EVI DHW cylinder, 200 to 500 l For applicability, see the last page VITOCELL 300-B

More information

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE

More information

CRU-S Series Stainless Steel Condensate Recovery Unit

CRU-S Series Stainless Steel Condensate Recovery Unit IM-UK-CRU-S UK Issue 1 CRU-S Series Stainless Steel Condensate Recovery Unit 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Storage, shutdown and equipment protection

More information

521 Series. MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions

521 Series.  MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions MixCal adjustable three-way thermostatic mixing valve 37. www.caleffi.com Copyright 15 Caleffi 51 Series Installation, commissioning and service instructions Function The Caleffi MixCal three-way thermostatic

More information

TECHNICAL PROPERTIES OF THE APPLIANCE

TECHNICAL PROPERTIES OF THE APPLIANCE TGR 30-120 SM EN Dear buyer, thank you for purchasing our product. Prior to the installation and first use of the electric water heater, please read these instructions carefully. THIS APPLIANCE IS NOT

More information

Installation, commissioning and servicing instructions. Technical Characteristics. -Lead Plumbing Law Certifi ed by IAPMO R&T

Installation, commissioning and servicing instructions. Technical Characteristics. -Lead Plumbing Law Certifi ed by IAPMO R&T www.caleffi.com 37. MixCal adjustable three-way thermostatic mixing valve Copyright Caleffi Installation, commissioning and servicing instructions Series Function The Caleffi MixCal three-way thermostatic

More information

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil 60. Item no: Z-3285

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil 60. Item no: Z-3285 Operating manual BlueMobil 60 Item no: Z-3285 Original operating manual Illustration shows item no Z-3285 Important Copyright It is essential that you read this manual thoroughly before the initial operation

More information

User Guide Topax Hygiene System. S Booster MP44/MP66/MP88

User Guide Topax Hygiene System. S Booster MP44/MP66/MP88 User Guide Topax Hygiene System S Booster MP44/MP66/MP88 Vers. 1.0 01.01.2012 Contents 1. Preface... 3 1.0 Application... 3 1.1 Warnings... 3 1.2 Safety Instructions... 4 2. Standard Unit... 5 3. Description

More information

Thermostatic valves with radiator connection systems

Thermostatic valves with radiator connection systems Multilux Eclipse Thermostatic valves with radiator connection systems with two-point connection for two-pipe heating systems, with automatic flow limitation IMI HEIMEIER / Thermostatic heads and Radiator

More information

Danfoss Air Heating Surfaces

Danfoss Air Heating Surfaces MAKING MODERN LIVING POSSIBLE Installation Guide www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English

More information

SCHWAN INSTALLATION GUIDE

SCHWAN INSTALLATION GUIDE 1 SCHWAN INSTALLATION GUIDE For Schwan SC60 FOR SERVICE OR ASSISTANCE CALL MERQUIP ON 0800 636 0 636. Schwan recommends that a qualified tradesperson installs your Schwan system. 2 INFORMATION AND SAFETY

More information

SD2. Differential Controller. Operating and Installation Instructions F2 72.3

SD2. Differential Controller. Operating and Installation Instructions F2 72.3 SD2 Differential Controller Operating and Installation Instructions F2 72.3 i Please follow the safety information and read these Instructions carefully before putting the system into operation. Safety

More information

Solar-Divicon and solar pump assembly. Please follow these safety instructions closely to prevent accidents and material losses.

Solar-Divicon and solar pump assembly. Please follow these safety instructions closely to prevent accidents and material losses. Installation and service instructions for contractors VIESMANN Solar-Divicon and solar pump assembly Safety instructions Please follow these safety instructions closely to prevent accidents and material

More information

Installation/Instruction Manual

Installation/Instruction Manual 1510876HC8902 Pressurized ventilators (for device cooling) Model Blade diameter (cm) Indoor or outdoor EF-20UYS-UL EF-25UAS-UL EF-30UBS-UL 20 25 30 Indoor Installation/Instruction Manual For customers

More information

HERZ Differential Pressure Control Valve 4002

HERZ Differential Pressure Control Valve 4002 HERZ Differential Pressure Control Valve 4002 Data sheet 4002, Issue 0118 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 71 1 4002 42 1 4002 62 1 4002 72 1 4002 43 1 4002 63 1 4002 73 1 4002 44 1 4002

More information

Instruction manual. Water treatment Boiler system D 30 L

Instruction manual. Water treatment Boiler system D 30 L Water treatment Boiler system D 30 L Manufacturer: deconta GmbH Im Geer 20, D - 46419 Isselburg Description / Type No.: Water treatment / D 30L /... Serial No.:... Table of contents 1 Introduction 3 2

More information

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341.

5231 Series.  Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341. NA3. www.caleffi.com Low Lead High Flow Thermostatic Mixing Valves Copyright 5 Caleffi Installation, commissioning and service instructions Function 53 Series ASSE 7 model 53 series high fl ow thermostatic

More information

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS www.regulus.eu LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE EN LYRA 1000 VVS CONTENTS 1 Description... 3 1.1 Models... 3 1.2 Tank protection... 3 1.3 Thermal insulation...

More information

Mounting and operating instructions KEMPER KTS temperature-controlled 3-directional reversing valve Figure DN 32 DN 80

Mounting and operating instructions KEMPER KTS temperature-controlled 3-directional reversing valve Figure DN 32 DN 80 Mounting and operating instructions KEMPER KTS temperature-controlled 3-directional reversing valve Figure 955 01 DN 32 DN 80 Figure 1: DN 32 - DN 50 Figure 2: DN 65 - DN 80 Table of Contents 1 General

More information

HOT WASHER MODEL NO: KING150

HOT WASHER MODEL NO: KING150 WARNING: Do not use the hot washer without reading this manual HOT WASHER MODEL NO: KING150 PART NO: 7320175 OPERATION & MAINTENANCE INSTRUCTIONS LS1215 INTRODUCTION Thank you for purchasing this CLARKE

More information

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user Electronically controlled instantaneous water heater MCX: 27300, 27400 and 27600 models Instructions for the user These appliances deliver water not exceeding 50 ºC in accordance with AS3498. 1. Overview

More information

QVE1901U Flow Switch. Technical Instructions Document No September 20, Description. Features. Application.

QVE1901U Flow Switch. Technical Instructions Document No September 20, Description. Features. Application. Document No. 55-7 September 0, 0 QVE90U Flow Switch Description Flow switch for liquids in piping 3/4-inch to 8-inch (0 mm to 00 mm) diameter Features Application Product Number Contact load/switching

More information

Glass and Dishwashers AMX / AUX Series

Glass and Dishwashers AMX / AUX Series Glass and Dishwashers AMX / AUX Series INSTALLATION OPERATION REV. 8.xx 04.07.2005 Installation and Operation Instructions for Models of AMX / AUX Series Content Page 1 Installation... 3 2 Connections...

More information

Saunier Duval Clima, S.A.

Saunier Duval Clima, S.A. Saunier Duval Clima, S.A. INSTALLATION MANUAL SDC/H 050 F SDC/H 065 F SDC/H 085 F SDC/H 105 F SDC/H 105T F SDC/H 120 M2F Safety Regulations...3 Indoor Unit Installation Dimensions... 4 Unit Location...

More information

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN. INSTALLATION, OPERATION & SERVICE MANUAL FOR COOLER TYPES OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN. 1. Introduction This manual is a guide for the installation, maintenance

More information

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation Standard Sheet for 6823/ 6824 Edition 1000 (0999) 6823 6824 Special Models 1

More information

Heating, air-conditioning, cooling

Heating, air-conditioning, cooling Series description Design landless circulation pup with threaded connection, blockingcurrent proof EC otor and integrated electronic power control. Application All hot water heating systes, air-conditioning

More information

Temperature Sensor TRG Original Installation Instructions English

Temperature Sensor TRG Original Installation Instructions English Temperature Sensor TRG 5-6.. EN English Original Installation Instructions 818597-05 1 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety note...4 Directives and standards

More information

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation OPERATING RANGE Flow rate of up to m /h Manometric head of up to m Max. operating pressure bar Min. intake pressure, bar at 9 C Water temperature range + at + C * EEI-Part, * for a ambient temperature

More information

Oil burners fuel unit with solenoid valve

Oil burners fuel unit with solenoid valve Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Germany VM_e.pdf - 18.05.08 Page 1/6 Oil burners fuel unit with solenoid valve

More information

Pump assembly Instruction manual

Pump assembly Instruction manual Instruction manual EN Version 2.0 /Release 06/2012 Table of content 1 Key background information...3 1.1 Limitation of liability...3 1.2 Responsibilities of the operator...3 1.3 Documentation...3 1.3.1

More information

VADA - Rain2Main Automatic Rainwater Controller

VADA - Rain2Main Automatic Rainwater Controller PRODUCT OVERVIEW / APPLICATION The Vada Rain2Main is designed to select between stored rainwater (when available) and mains supply water, and send this water to your toilet cistern, washing machine, garden

More information

Installation Instructions

Installation Instructions Installation Instructions For Fully Integrated NoFrost Combined Refrigerator-Freezers HCB 1560/1561 HC 1550 7084 327-00 Important Please Read and Follow these Instructions These instructions contain Danger,

More information

USER S MANUAL DN-2. Drain pump

USER S MANUAL DN-2. Drain pump USER S MANUAL DN-2 CONTENTS Safety requirements... 2 Purpose... 3 Delivery set... 3 Technical data... 3 Design... 4 Installation and set-up... 5 Connection to power mains... 8 Storage and transportation

More information

s l it l on for Infrared Heaters

s l it l on for Infrared Heaters Installation and Instruction Manual for Infrared Heaters Contents Safety and operating instructions... 3 Scope of supply... Installation instructions... 4 5 Initial operation... 10 Cleaning instructions...

More information

LABOPORT. Chemically-resistant Laboratory Pumps with Modular Accessories. Operating Instructions for Laboratory Pumps. and for LABOPORT Systems

LABOPORT. Chemically-resistant Laboratory Pumps with Modular Accessories. Operating Instructions for Laboratory Pumps. and for LABOPORT Systems LABOPORT Chemically-resistant Laboratory Pumps with Modular Accessories Operating Instructions for Laboratory Pumps and for LABOPORT Systems SR..., SH, SC, SCC UN810FTP UN820FTP UN840FTP UN810.3FTP UN820.3FTP

More information

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage Model: 1090 1 Safety instructions Float-Controlled Condensate Trap, PN 16 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination

More information

VWZ MEH 61. Installation instructions and instructions for use. Installation instructions and instructions for use

VWZ MEH 61. Installation instructions and instructions for use. Installation instructions and instructions for use Installation instructions and instructions for use For the competent person and the operator Installation instructions and instructions for use VWZ MEH 6 GB TABLE OF CONTENTS Safety...3. Intended use...3.

More information

Installation Instructions

Installation Instructions Installation Instructions For Fully Integrated NoFrost Combined Refrigerator-Freezers HC 2062 HCB 2062 HC/HCB 2062 7084 445-00 Important Please read and follow these instructions These instructions contain

More information

Calio-Therm S NC/NCV Type Series Booklet

Calio-Therm S NC/NCV Type Series Booklet High-efficiency Drinking Water Pump Calio-Therm S NC/NCV Type Series Booklet Legal information/copyright Type Series Booklet Calio-Therm S NC/NCV All rights reserved. The contents provided herein must

More information

MD SERIES Instruction Manual

MD SERIES Instruction Manual IWAKI Magnetic Drive Pump MD SERIES Instruction Manual Read this manual before use of product Thank you for having selected the Iwaki Magnetic Drive Pump MD series. This manual deals with the correct handling

More information