DIEMATIC 3 - FM129 DIEMATIC 3 CH - FM133

Size: px
Start display at page:

Download "DIEMATIC 3 - FM129 DIEMATIC 3 CH - FM133"

Transcription

1 GT 0 - GTUC 0 - GT 0 - GTUC 0 en Control panel DIEMATIC 3 - FM9 DIEMATIC 3 CH - FM33 Installation instructions

2 Contents Symbols used General Installing the outside sensor Positions to be avoided Installing the outside sensor Fitting the flow sensor Electrical connections Important recommendations Type of connection General Terminal block Basic connections Connecting circuit B Connecting the options Connection of a second domestic hot water tank Pool connection Connecting a pool and preparation for solar heated domestic hot water Connecting one or two circuits with mixer valve Hot water storage tank connection Basic connections if the installation is in cascade and when connecting to a regulation DIEMATIC VM Skeleton Diagrams DIEMATIC 3 - GT 0 / 0 7//

3 . Symbols used Symbols used Caution danger Risk of injury and damage to equipment. Attention must be paid to the warnings on safety of persons and equipment Specific information Information must be kept in mind to maintain comfort Reference Refer to another manual or other pages in this instruction manual DHW: Domestic hot water General Control panel assembly See: Boiler installation instructions. Fitting the boiler sensor See: Boiler installation instructions. Connection of the water circuit for domestic use See: Calorifier instructions. Installing options See: Option instructions. Parameter settings and installation configuration See: Control panel technical instructions. 7// DIEMATIC 3 - GT 0 / 0 3

4 3 Installing the outside sensor Choose a location: - on one face of the area to be heated, on the north if possible - under the influence of meteorological variations - protected from direct sunlight - easy to access Z: Inhabited area controlled by the sensor H: Inhabited height controlled by the sensor A: recommended position on a corner B: Possible position 3. Positions to be avoided 3. Installing the outside sensor CB Ø 4 wood screw + Inserts (provided) 4 DIEMATIC 3 - GT 0 / 0 7//

5 4 Fitting the flow sensor 4. Fitting the flow sensor Heating circuit with mixing valve The flow sensor with connecting cable (length.5 m) and connector plug should be fitted to the outlet circuit pipe concerned and must be connected to the point provided in the control panel as shown hereafter. The flow sensor after the valve must be positioned around 0.5 m after the 3 way valve or after the heating pump if this is fitted to the outlet. - Cut the pipe insulation by 50 mm. - At the point where the sensor is fitted, thoroughly clean the pipes (there must be no trace of paint) and coat them with the ready-touse contact paste provided in the syringe. - Secure the sensor with the collar provided for this purpose. The flow sensor must not be covered by the insulation around the pipe. 7// DIEMATIC 3 - GT 0 / 0 5

6 5 Electrical connections 5. Important recommendations The power supply must be cut prior to any intervention on the heating installation (for example, via the appropriate fuse or a general switch)and any restart must be prevented. Connections must be made by a qualified technician Do not modify the connections inside the control panel. All connections are made to the terminals on the control panel. Separate the sensor cables from the 30 V cables. In the boiler: Use the boiler's grommets: Use cableways at least 0 cm apart. Attach the cables to the cable clamps provided for this purpose. GT 0 GT 0 30 V main supply For Switzerland: Power supply cable Supplied Sensors Cable clamps 5. Type of connection For the 30 V electrical connections, use 3-wire cables with a crosssection of,5 mm². Keep to the polarity shown on the terminals: phase (L), neutral (N) and earth ( ). 5.3 General Make the electrical connections of the appliance according to: - The instructions of the prevailing standards, - The instructions on the circuit diagrams provided with the appliance, - The manufacturer's instructions. Power the appliance via a circuit which includes a remote omnipolar switch with a gap of more than 3 mm. Earthing shall comply with standard NFC 500 (France) or RGBT (Belgium). The available output per outlet is 450 W ( A, with cos ϕ = 0,7) and the inrush current must be lower than 6 A. If the charge exceeds one of these values, relay the command using a contactor (fitted outside the control panel). 6 DIEMATIC 3 - GT 0 / 0 7//

7 5. Electrical connections 5.4 Terminal block State on delivery 6 x 0,75 mm mini. -B (A) All countries except Switzerland: To connect the mixing valve PCB + sensor options - See: Instructions for option FM48, AD7 (B) For Switzerland: To connect the mixing valve PCB + sensor options - See: Instructions for option FM48, AD7 Boiler sensor 3 Boiler remote control input 4 Alarm output 5 Connecting the TELCOM vocal telesurveillance module See chapter: Connecting the options 6 Flue gas thermostat 7// DIEMATIC 3 - GT 0 / 0 7

8 5.5 Basic connections For Switzerland: circuit B See next page BUS DIEMATIC DIEMATIC BUS OPTION - ZUBEHÖR OPTION - ZUBEHÖR P HONIQUE Y HONE IS E L E P IS E UXIL IA IR Y UXIL IA R S A A UC UE A T IR S SONDE - FÜHLER - SENSOR C CIRCUIT C B C B UIT IR UIT C C C B UIT IS CUIT CIR CUIT CIR IS IS IA IA R R UF B CIRCUIT A A UIT B B A UIT IS CUIT CIR IS IA R R UF P OMP E A UXIL IA IR E HIL F S A US G A NG A UXIL IA R Y OUT P UT C HA R G E DE P OMP E D E R L UMP E IZUNG S P UMP UMP UR ING V OY A NT A L A R ME A L A R ML E UC HT E ALAR M INDICATOR C ONT A C T DE S E C UR IT E S IC HE R HE IT S K ONT A K T S A F E T Y C ONT A C T A L IME NT A T ION 30 V 50Hz S T R OMZUF UHR 30 V 50Hz MA IN S UP P L Y 30 V 50Hz -A 8575N576 S AMB S DEP S AMB S DEP S AMB S SOL S F S AUX (C) (C) (B) (B) (A) TA S ECS S CH S EXT AUX (A) VA 4 3 o o o o o o o o o o o o o o o o o o 4 4 o o o o o o AU X N L N L A N L VA + CS N L Alim 30 V - 50 H z N L 0 x 0,75 mm mini. 3 x 0,75 mm mini. 3 x 0,75 mm mini. x 0,75 mm mini. x 0,75 mm mini. 3 x,5 mm mini V main supply Flue gas thermostat 3 Burner fault alarm light 4 Pump circuit A 5 D.H.W. load pump 6 DHW sensor 7 Titanium anode 8 Outside sensor 9 Boiler sensor 0 Boiler with or without accumulator 8 Boiler with accumulator DIEMATIC 3 - GT 0 / 0 7//

9 5. Electrical connections 5.6 Connecting circuit B Originally for Switzerland, FM48 option for other countries. Remote control (circuit B) (package FM5 or FM5) Flow sensor (circuit B) 3 3-way valve (circuit B) 4 Pump (circuit B) 5 Safety thermostat 6 Remove bridge () If using a two-way motor Connect open to terminal 3, close to terminal and neutral to terminal 4 (N). If using a thermal motor Connect between terminal 3 (open) and terminal (N). () Safety thermostat If using underfloor heating, it is imperative that a temperature limit of 50 C is installed and a safety thermostat set to 65 C (cf. NF P ) is fitted, which interrupts the operation of the circulating pump in the circuit concerned should overheating occur. Connect the safety thermostat wires to the 5 pin connector at the point marked TS(B) terminals 7-8 after removing the jumper from terminals 7-8. If the safety thermostat is fitted with an earth wire, connect the thermostat to the earth terminal on pump. 7// DIEMATIC 3 - GT 0 / 0 9

10 5.7 Connecting the options For example: Solar collector, TELCOM vocal telesurveillance module, remote controls for circuits A and B, flue gas sensor. -A V main supply Flue gas thermostat 3 Burner fault alarm light 4 Pump circuit A 5 DHW sensor (Package AD) 6 Titan Active System simulation connector (package AD) 7 Outside sensor 8 Boiler sensor 9 Outlet sensor 0 Interactive remote control (package FM5 or FM5) Flue gas sensor TELCOM voice remote monitoring module (depending on its availability in your country) 3 Solar sensor probe 4 Boiler with or without accumulator 5 Boiler with accumulator 6 DHW sensor (Package AD60) For connection of solar collectors: adjust the S.AUX parameter (# FITTER PARAM.) to SOLAR. 7 D.H.W. load pump 8 Solar load pump 0 DIEMATIC 3 - GT 0 / 0 7//

11 5. Electrical connections 5.8 Connection of a second domestic hot water tank This connection is possible if circuit A is not used -A V main supply Flue gas thermostat 3 Burner fault alarm light 4 DHW sensor (Package AD) 5 D.H.W. load pump 6 Outside sensor 7 Boiler sensor 8 Boiler with or without accumulator 9 Boiler with accumulator If connecting a second DHW tank, use circuit A: - set the CIRC.A parameter (#. INSTAL PARAM.) to DHW. - Fit the sensor (package AD ) into the second DHW tank. - Connect the sensor to the S.AUX input. - Adjust the TEMP.DHW A set temperature using the key C range to obtain a domestic hot water calorifier type operation. 7// DIEMATIC 3 - GT 0 / 0

12 5.9 Pool connection This connection is possible if circuit A is not used A 30 V main supply Flue gas thermostat 3 Burner fault alarm light 4 Swimming pool sensor (Package AD) 5 Pool secondary pump 6 Primary pump pool 7 Outside sensor 8 Boiler sensor DIEMATIC 3 - GT 0 / 0 7//

13 5. Electrical connections Controlling the pool circuit The DIEMATIC 3 regulation can be used to control a pool circuit in two different cases: Case The regulation DIEMATIC 3 regulates the primary circuit (boiler / exchanger) and the secondary circuit (exchanger / pool). - Set the value of TPC D to the temperature which corresponds to the needs of the exchanger. Hourly programming of the secondary circuit pump The secondary pump operates during programme A comfort periods in summer and winter alike. Stopping To prepare your pool for winter, consult your pool specialist. - Set the parameter S.AUX (#FITTER PARAM.) to SWIM.P. - Set the parameter CIRC. A: (#FITTER PARAM.) to SWIM.P. - Connect the primary circuit pump (boiler/exchanger) to the pump A outlet. The TPC J temperature is then maintained during programme A comfort periods in summer and in winter. - Connect the pool sensor (package AD) to the S.AUX: input. - Set the value of the pool sensor using key in the range C or to FF (Frost Free). - With an FF setting, the primary pump starts up and the secondary pump stays off if the installation's antifreeze function is activated. Case The pool has already a regulation system that is to be kept. The DIEMATIC 3 control unit only regulates the primary circuit (boiler/ exchanger). - Set the value of TPC D to the temperature which corresponds to the needs of the exchanger. - Set the CIRC.A parameter in #INSTAL PARAM. to POOL - Connect the primary circuit pump (boiler/exchanger) to the pump A outlet. The TPC J temperature is then maintained during programme A comfort periods in summer and in winter. 7// DIEMATIC 3 - GT 0 / 0 3

14 5.0 Connecting a pool and preparation for solar heated domestic hot water This connection is possible if circuit A and either circuit B or C are not used. -A DIEMATIC 3 - GT 0 / 0 7//

15 5. Electrical connections 30 V main supply Flue gas thermostat 3 Burner fault alarm light 4 Primary pump pool 5 Pool secondary pump 6 Swimming pool sensor (Package AD) 7 DHW sensor 8 DHW sensor (Package AD) 9 D.H.W. load pump 0 Solar load pump Outside sensor Boiler sensor 3 Titan Active System simulation connector (package AD ) 4 Solar sensor probe Parameter settings - Fit the mixing valve PCB + sensor option (Package FM 48) - adjust the S. AUX parameter to SWIM. P. - adjust the CIRC.A parameter to SWIM. P. - adjust the CIRC.B parameter to SOLAR 5. Connecting one or two circuits with mixer valve To connect the mixing valve PCB + sensor options - See: Instructions for option FM48 For Switzerland: PCB + sensor for a mixing valve is already prefitted to the control panel. 7// DIEMATIC 3 - GT 0 / 0 5

16 5. Hot water storage tank connection -A V main supply Flue gas thermostat 3 Burner fault alarm light 4 Pump circuit A 5 Outside sensor 6 Boiler sensor 7 Titan Active System simulation connector (package AD) 8 DHW sensor (Package AD) 9 Hot water storage tank sensor (Package AD60) 0 Buffer tank D.H.W. load pump Heating load pump The storage tank handles heating and DHW production. Package AD60 contains sensors: - The sensor for the solar panel is used as a storage tank sensor - The sensor for the storage tank is used as a DHW sensor Parameter settings Set the parameter STOR.T.SENS (#CONFIGURATION) to ON. Operation In DHW production: Operation is the same as the normal operation. The boiler setting only is equal to the DHW setting +0 K. The heating load pump is off. In heating mode: The burner and the heating load pump: -are off if the temperature of the storage tank is higher than the boiler setting. -start up if the temperature of the storage tank falls below the boiler setting -6 K. 6 DIEMATIC 3 - GT 0 / 0 7//

17 5. Electrical connections 5.3 Basic connections if the installation is in cascade and when connecting to a regulation DIEMATIC VM (Without option AD7) 5.3. Master boiler 3 4 -A V main supply Flue gas thermostat 3 Burner fault alarm light 4 Primary injection pump 5 D.H.W. load pump 6 Titan Active System simulation connector (package AD ) 7 DHW sensor 8 D.H.W. loop back pump 9 Outside sensor 0 Boiler sensor Boiler with or without accumulator Boiler with accumulator 3 To the Diematic VM () regulation 4 To secondary boiler () () The boiler can be connected to a boiler in cascade or to a DIEMATIC VM using a BUS cable (package AD34 or DB9). 7// DIEMATIC 3 - GT 0 / 0 7

18 5.3. Secondary boiler 7 8 -B V main supply Flue gas thermostat 3 Burner fault alarm light 4 Primary injection pump 5 Boiler sensor (Follower boiler) 6 Boiler with or without accumulator 7 From the previous cascade boiler 8 Not used 9 Boiler sensor on common output 8 DIEMATIC 3 - GT 0 / 0 7//

19 5. Electrical connections Cascade Master boiler Secondary boiler 3 Primary injection pump 4 Common outlet sensor to be connected to the S ECS input on boiler 5 Mixing valve and circulating pump To connect the mixing valve PCB + sensor options, See: Instructions for option FM48 To construct the cascade, set the parameter CASCADE (#CONFIGURATION) on each boiler to and respectively. Set the parameter CIRC. A: to PRIM.P. on boiler. The boilers switch over every 7 days. If necessary, the startup of the secondary boiler is timed at 4 minutes. 7// DIEMATIC 3 - GT 0 / 0 9

20 6. Skeleton Diagrams 6 Skeleton Diagrams Schéma de principe - Stromlaufplan - Principle diagram - Principeschema "DIEMATIC III" θ a DJ 6A TS a ZG a TEST STB b a b a ZT ZM VA TCH ZT a b å å AUTO AUTO AUTO b a TEST STB a b A B C Ë Ã ÀÈÁ Ä AUTO J3 J3 J3 3 J3 4 J3 5 J3 8 J3 7 J3 6 J3 9 J J J 3 J 4 J 5 J3 0 FA RL BR 4 V (RL) RL PA RL ECS RL AUX Alim 30 V-50Hz L N Ä A L N Ä Ã Ä AUX L N L N N L J 4 J 6 J 3 VA CS J J 5 J S EXT S CH S ECS T A + - S AMB A S DEP B S AMB B S DEP C S AMB C S AUX S FUMEE S SOL Ì 3 4 Ì Ì θ C θ C θ C θ C θ C θ C θ C θ C B4 S3 T T L N Ë Ä A ACCELERATEUR CIRCUIT A KESSELKREISPUMPE KREIS A S AUX SONDE AUXILLIAIRE FÜHLER ZUSATZ Ä A HEATING PUMP CIRCUIT A VERWARMINGSPOMP KRING A S AUX AUXILIARY SENSOR VACUUM VOELERS Ä Ã POMPE DE CHARGE SPEICHERLADEPUMPE S CH SONDE CHAUDIERE KESSELFÜHLER Ä Ã LOAD PUMP LAADPOMP S CH BOILER SENSOR KETEL VOELERS Ä AUX POMPE AUXILIAIRE ZUSATZPUMPE S DEP SONDE DE DEPART VORLAUFFÜHLER Ä AUX AUXILIARY PUMP HULPUITGANGPOMP S DEP FLOW SENSOR VERTREVOELER CS CONTACT DE SECURITE SICHERHEITSKONTAKT S ECS SONDE EAU CHAUDE SANITAIRE WARMWASSERFÜHLER CS SAFETY CONTACT VEILIGHEIDSCONTACT S ECS DOMESTIC HOT WATER SENSOR SANITAIR WARM WATER VOELERS DJ6A DISJONCTEUR LEISTUNGSSCHALTER S EXT SONDE EXTERIEURE AUSSENFÜHLER DJ6A CIRCUIT BREAKER THERMISCHE BEVEILIGING S EXT OUTSIDE SENSOR BUITEN VOELERS Ë BRULEUR BRENNER S FUMEE SONDE FUMEE ABGASFÜHLER Ë BURNER BRANDER S FUMEESMOKE SENSOR ROOKGASSEN VOELERS FA FILTRE ANTIPARASITE FUNKENENSTÖRUNGSFILTER S SOL SONDE SOLAIRE SOLAR FÜHLER FA EMI SUPPRESSOR ONSTORINGS-FILTER S SOL SOLAR SENSOR SOLAR VOELERS Ì RELAIS TELEPHONIQUE FERNSPRECHRELAIS T A ANODE A COURANT IMPOSE FREMDSTROMANODE Ì TELEPHONE RELAY TELEFONISCH RELAIS T A ELECTRIC ANODE CORROSIEBESCHERMINGSANODE CONNECTEUR CIRCUIT IMPRIME LEITERPLATTE STECKER TCH THERMOSTAT DE CHAUDIERE KESSEL TEMPERATURREGLER J. PRINTED CIRCUIT BOARD PLUG AANSLUITKLEM TCH BOILER THERMOSTAT KETELTHERMOSTAAT J. PHASE PHASE TS THERMOSTAT DE SECURITE SICHERHEITSTEMPERATURBEGRENZER PHASE FASE TS SAFETY THERMOSTAT VEILIGHEIDSTHERMOSTAAT NEUTRE NULLEITER VA VOYANT ALARME ALARMLEUCHTE N NEUTRAL NULLEIDER VA ALARM INDICATOR ALARM LAMPJE N RL AUX RELAIS DE COMMANDE POMPE ZUSATZPUMPE STEUERRELAIS ZG INTERRUPTEUR GENERAL HAUPTSCHALTER RL AUX AUXILIARY PUMP CONTROL RELAY AFZONDERINGSKLEP RELAIS ZG MAIN SWITCH ALGEMENE SCHAKELAAR AUXILIAIRE RL BR RELAIS DE COMMANDE BRULEUR BRENNER STEUERRELAIS ZM INTERRUPTEUR MANUEL UMSCHALTER FÜR HANDBETRIEB RL BR BURNER CONTROL RELAY BRANDER RELAIS ZM MANUAL MODE SWITCH MANUEL SCHAKELAAR RL ECS RELAIS DE COMMANDE POMPE DE SPEICHERLADEPUMPE STEUERRELAIS ZT INTERRUPTEUR TEST TESTSCHALTER RL ECS LOAD PUMP CONTROL RELAY RELAIS STURING LAADPOMP ZT TEST SWITCH TEST SCHAKELAAR CHARGE RL PA RELAIS DE COMMANDE ACCELERATEUR HEIZUNGSPUMPE STEUERRELAIS RL PA HEATING PUMP CONTROL RELAY VERWARMINGSPOMPE RELAIS S AMB SONDE D' AMBIANCE RAUMFÜHLER S AMB ROOM SENSOR RUIMTEVOELER Plan n : A L 3 L 0 DIEMATIC 3 - GT 0 / 0 7//

21 6. Skeleton Diagrams 7// DIEMATIC 3 - GT 0 / 0

22 6. Skeleton Diagrams DIEMATIC 3 - GT 0 / 0 7//

23 6. Skeleton Diagrams 7// DIEMATIC 3 - GT 0 / 0 3

24 DE DIETRICH THERMIQUE S.A.S +49 (0)5 7 / (0)5 7 / 96-0 info@remeha.de 964,. +7 (495) -3-5 info@dedietrich.ru ES DE DIETRICH THERMIQUE Iberia S.L.U. C/Salvador Espriu, L HOSPITALET de LLOBREGAT info@dedietrich-calefaccion.es DE DIETRICH SERVICE Freecall 0800 / 0608 IT CZ DUEDI S.r.l. Distributore Ufficiale Esclusivo De Dietrich-Thermique Italia Via Passatore, - 00 San Defendente di Cervasca CUNEO info@duediclima.it BDR Thermea (Czech republic) s.r.o Jeseniova 770/ Praha dedietrich@bdrthermea.cz AD00-AM Copyright All technical and technological information contained in these technical instructions, as well as any drawings and technical descriptions supplied, remain our property and shall not be multiplied without our prior consent in writing. Subject to alterations. 7// DE DIETRICH THERMIQUE 57, rue de la Gare F MERTZWILLER - BP 30

Control panel B - FM126 B2 - FM159. Installation and Service Manual

Control panel B - FM126 B2 - FM159. Installation and Service Manual en Control panel B - FM126 B2 - FM159 Installation and Service Manual 300002725-02 Contents 1 Symbols used...........................................................................3 2 Important recommendations...............................................................3

More information

Package FT 74. X control panel. Installation and Service Manual

Package FT 74. X control panel. Installation and Service Manual en Package FT 74 X control panel Installation and Service Manual 7647029-03 . Contents 1 Safety instructions.......................................................................3 1.1 Important recommendations................................................................................3

More information

Control panel (MD3) to be placed on the boiler (MD140) lateral control panel

Control panel (MD3) to be placed on the boiler (MD140) lateral control panel GT 330 - GT 430 - GT 530 - GTU C 330 Control panel B3 EN Control panel (MD3) to be placed on the boiler (MD140) lateral control panel Installation and Service Manual 300008923-001-C . Contents 1 Symbols

More information

Control panel B/B2. Package FM126 - Control panel B Package FM159 - Control panel B2. Technical instructions. Installation instructions

Control panel B/B2. Package FM126 - Control panel B Package FM159 - Control panel B2. Technical instructions. Installation instructions Control panel B/B2 Package FM126 - Control panel B Package FM159 - Control panel B2 English 17/01/06 Installation instructions Technical instructions Contents Symbols used................................................................................3

More information

Control panel K3. Package MD2. Technical instructions. Installation instructions. English 08/02/06

Control panel K3. Package MD2. Technical instructions. Installation instructions. English 08/02/06 Control panel K3 Package MD English 08/0/06 Installation instructions Technical instructions Contents Symbols used................................................................................3 Important

More information

S3 standard control panel

S3 standard control panel S3 standard control panel Package MD4 English 23/01/06 Installation instructions Technical instructions Contents Symbols used................................................................................3

More information

Control panel. Package RC 6. Installation and Service Manual A

Control panel. Package RC 6. Installation and Service Manual A EN Control panel Package RC 6 Installation and Service Manual 3000303-00-A Contents Introduction.............................................................................3. Symbols and abbreviations................................................................................3.

More information

C 230 ECO. Control panel. DIEMATIC-m3 (GV6) Installation and Service Manual E

C 230 ECO. Control panel. DIEMATIC-m3 (GV6) Installation and Service Manual E C 230 ECO Control panel DIEMATIC-m3 (GV6) EN Installation and Service Manual 300015243-001-E Contents 1 Introduction.............................................................................3 1.1 Used

More information

Low temperature gas boiler DTG 330 S. User Guide

Low temperature gas boiler DTG 330 S. User Guide en Low temperature gas boiler DTG 330 S User Guide 300011852-02 . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3

More information

After Sales Service Guide

After Sales Service Guide After Sales Service Guide Control panel DIEMATIC isystem For INNOVENS MCA wall-hung gas condensing boilers 300022803-00-B /02/200 Use of this guide is reserved for qualified professionals Any intervention

More information

Gas fired condensing boiler C 230 ECO. User Guide

Gas fired condensing boiler C 230 ECO. User Guide en Gas fired condensing boiler C 230 ECO User Guide 300015144-02 Contents 1 Safety instructions.......................................................................3 1.1 General safety instructions.................................................................................3

More information

DTG130-45/65/90/115 Eco.NOx Plus

DTG130-45/65/90/115 Eco.NOx Plus ELIDENS Gas fired condensing boiler DTG130-45/65/90/115 Eco.NOx Plus en User Guide 300005222-03 Contents 1 Safety instructions.......................................................................3 1.1

More information

BSC...E - BSP...E - BESC...E

BSC...E - BSP...E - BESC...E INISOL DUO E DIETRISOL DUO E Solar hot water calorifer BSC...E - BSP...E - BESC...E EN User Guide 0007781-001-01 Contents 1 Introduction.............................................................................

More information

Domestic hot water tank SR130. Installation, User and Service Manual

Domestic hot water tank SR130. Installation, User and Service Manual EN Domestic hot water tank SR130 Installation, User and Service Manual 300009755-001-03 Contents 1 Introduction...4 1.1 Symbols used...4 1.2 Abbreviations...4 1.3 Liabilities...4 1.3.1 Manufacturer s liability...4

More information

DIEMATIC VM isystem WALL-MOUNTED CONTROL SYSTEM. DIMENSIONS Length: 320 mm Height: 260 mm Depth: 130 mm. POWER SUPPLY 230 V, 50 Hz, 6 A

DIEMATIC VM isystem WALL-MOUNTED CONTROL SYSTEM. DIMENSIONS Length: 320 mm Height: 260 mm Depth: 130 mm. POWER SUPPLY 230 V, 50 Hz, 6 A DIEMATIC WALL-MOUNTED CONTROL SYSTEM Electronic control system capable of controlling 2 heating circuits, a DHW circuit and an auxiliary circuit EC identification No.: 0085CM0178 Electronic microprocessor

More information

MCR-P 24 MCR-P 24/28 MI MCR-P 30/35 MI MCR-P 34/39 MI

MCR-P 24 MCR-P 24/28 MI MCR-P 30/35 MI MCR-P 34/39 MI Vivadens EN Wall-hung gas condensing boilers MCR-P 24 MCR-P 24/28 MI MCR-P 30/35 MI MCR-P 34/39 MI User Guide 127684-01 Contents 1 Introduction...4 1.1 Symbols used...4 1.2 Abbreviations...4 1.3 General...5

More information

Innovens Pro. Wall-hung gas condensing boilers MCA Installation and Service Manual A

Innovens Pro. Wall-hung gas condensing boilers MCA Installation and Service Manual A Innovens Pro EN Wall-hung gas condensing boilers MCA 45-65 - 90-5 Installation and Service Manual 3000487-00-A EG declaration of conformity The device complies with the standard type described in the EG

More information

Vivadens. Wall-hung gas condensing boilers MCR 24/28 BIC. User Guide B

Vivadens. Wall-hung gas condensing boilers MCR 24/28 BIC. User Guide B Vivadens EN Wall-hung gas condensing boilers MCR 24/28 BIC User Guide 300024112-001-B Contents 1 Introduction...4 1.1 Symbols used...4 1.2 Abbreviations...4 1.3 General...4 1.3.1 Manufacturer's liability...4

More information

WHE 2.24 / WHE 2.24 FF

WHE 2.24 / WHE 2.24 FF EN Wall-hung gas boilers WHE 2.24 WHE 2.24 FF User Guide 300011777-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3

More information

Range GT GTU C GT 220

Range GT GTU C GT 220 Range GT 120 - GTU C 120 - GT 220 Low temperature fuel oil boiler Oil-fired condensation boiler English 21/09/06 Instructions for use Contents Important recommendations...................................................................3

More information

DTG X.. N. Low temperature gas furnace. Instructions for use. English 14/11/2005

DTG X.. N. Low temperature gas furnace. Instructions for use. English 14/11/2005 DTG X.. N Low temperature gas furnace English 14/11/2005 Instructions for use Contents Important recommendations...................................................................3 1 Aeration.................................................................................................3

More information

TWH 200E TWH 300E TWH 300EH

TWH 200E TWH 300E TWH 300EH KALIKO Export EN Thermodynamic water heater TWH 200E TWH 300E TWH 300EH User Guide C003182-C 7605313-001-07 Contents 1 Safety instructions and recommendations...4 1.1 Safety instructions...4 1.1.1 Installation...4

More information

isense Pro DIN - AD280

isense Pro DIN - AD280 EN Regulation isense Pro DIN - AD80 C00695-A Installation and Service Manual 30005649-00-0 Contents Introduction...4. Symbols used...4. Abbreviations...4.3 General...4.3. Manufacturer s liability...4.3.

More information

ADVANCE EASYLIFE PROJECT

ADVANCE EASYLIFE PROJECT ADVANCE EASYLIFE PROJECT DIEMATIC 3 and -m 3 control panels... p. 232 DIEMATIC isystem control panel... p. 234 DIEMATIC 3 DIEMATIC VM isystem wall-hung control unit... p. 235 Room thermostats and miscellaneous...

More information

Gas-fired boilers DTG 230. User Guide D

Gas-fired boilers DTG 230. User Guide D EN Gas-fired boilers DTG 230 User Guide 300011506-001-D . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3

More information

GT 120 >> >> >> << >> Sustainable Comfort. Longlasting comfort

GT 120 >> >> >> <<   >> Sustainable Comfort. Longlasting comfort SOLAR SOLID FUEL HEAT PUMPS CONDENSING OIL/GAS GAS FLOOR STANDING BOILER ADVANCE Longlasting comfort >> >> >> Silence and durability Customized solutions and comfort Provides the quality of an integrated

More information

Oil-fired condensing boiler GTU C 330. User Guide B

Oil-fired condensing boiler GTU C 330. User Guide B EN Oil-fired condensing boiler GTU C 330 User Guide 300017846-001-B . Contents 1 Introduction.............................................................................3 1.1 Symbols and abbreviations................................................................................3

More information

DTG Eco / V130

DTG Eco / V130 ECODENS Gas fired condensing boiler EN User Guide 300010111-001-B Contents 1 Introduction.............................................................................3 1.1 Symbols and abbreviations................................................................................3

More information

Wood-burning boiler CBB. User Guide E

Wood-burning boiler CBB. User Guide E EN Wood-burning boiler User Guide 300008541-001-E . Contents 1 Symbols used...........................................................................3 2 Important recommendations...............................................................3

More information

PRODUCT CATALOGUE

PRODUCT CATALOGUE PRODUCT CATALOGUE 010- PROJECT INNOVENS PRO CA 5-115 from 8.9 to 11 (7.6-98.0 cal/h) Wall-hung gas condensing boilers P. PROJECT INNOVENS PRO CA 5-115 CASCADE SYSTES from 80 to 8 (68.8-368 cal/h) Complete

More information

4FLOOR-STANDING GAS CONDENSING BOILERS

4FLOOR-STANDING GAS CONDENSING BOILERS EASYLIFE PROJECT / SOLNEO / ECODENS RESIDENTIAL DTG (E) 130-15/25 Eco. NOx Plus DTG (E) 1300-15/25 Eco. NOx Plus/B150 DTG (E) 1300-15/25 Eco. NOx Plus/H150 DTG 1300-15/25 Eco. NOx Plus/V130 4FLOOR-STANDING

More information

FLOOR STANDING GAS CONDENSING BOILERS CONDITION OF USE CLASSIFICATION

FLOOR STANDING GAS CONDENSING BOILERS CONDITION OF USE CLASSIFICATION C /6- ECO FLOOR STANDING GAS CONDENSING OILERS C - Eco: from 56 to 5 kw, gas condensing boilers simple body, for hot water central heating and DHW production with independent calorifier C 6- Eco: from

More information

GT 220 PROJECT CAST IRON FLOOR-STANDING FUEL OIL-/GAS-FIRED BOILERS

GT 220 PROJECT CAST IRON FLOOR-STANDING FUEL OIL-/GAS-FIRED BOILERS GT CAST RON FLOOR-STANDNG FUEL OL-/GAS-FRED BOLERS GT : for hot water central heating only GT : for hot water central heating and domestic hot water production with a 16- or 5-litre calorifier under the

More information

HPI REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER

HPI REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER /E: from to kw with additional heating by integrated electrical resistance /H: from to kw with additional hydraulic heating by boiler (or without additional

More information

GT 220 CAST IRON FLOOR-STANDING FUEL OIL- / GAS-FIRED BOILERS

GT 220 CAST IRON FLOOR-STANDING FUEL OIL- / GAS-FIRED BOILERS GT CAST RON FLOOR-STANDNG FUEL OL- / GAS-FRED BOLERS GT : for hot water central heating only GT : for hot water central heating and domestic hot water production with a 16- or 5-litre calorifier under

More information

CALORA TOWER GAS 15S EX CALORA TOWER GAS 25S EX CALORA TOWER GAS 35S EX

CALORA TOWER GAS 15S EX CALORA TOWER GAS 25S EX CALORA TOWER GAS 35S EX EN Floor-standing high efficiency gas boiler CALORA TOWER GAS 15S EX CALORA TOWER GAS 25S EX Installation and Service Manual C003589-A 300026141-001-07 Declaration of conformity The device complies with

More information

MCA 15 - MCA 25 MCA 25/28 MI

MCA 15 - MCA 25 MCA 25/28 MI Innovens EN Wall-hung gas condensing boilers MCA 5 - MCA 5 MCA 5/8 MI Installation and Service Manual 300046-00-B MCA 5 - MCA 5 MCA 5/8 MI Declaration of conformity The appliance complies with the standard

More information

<< >> Condensing technology at the service of oil. Controlling energy to save money

<<   >> Condensing technology at the service of oil. Controlling energy to save money SOLAR SOLI D FUE L H EAT PUMPS CON DE NSI NG OI L/GAS GTU C 120 O I L - F I R E D C O N D E N S I N G B O I L E R S ADVANCE Condensing technology at the service of oil >

More information

Gas fired condensing boiler C 230 ECO. User Guide C

Gas fired condensing boiler C 230 ECO. User Guide C EN Gas fired condensing boiler C 230 ECO User Guide 300015144-001-C Contents 1 Introduction.............................................................................3 1.1 Used symbols...........................................................................................3

More information

Solar regulator DIEMASOL C. Installation and Service Manual. User Guide G

Solar regulator DIEMASOL C. Installation and Service Manual. User Guide G EN Solar regulator DIEMASOL C Installation and Service Manual User Guide 300005750-001-G . Copyright All sections of these instructions for installation and use are protected by copyright. Any use likely

More information

SOLNEO SGC 24 SOL. User Guide. Gas fired condensing boiler C

SOLNEO SGC 24 SOL. User Guide. Gas fired condensing boiler C SOLNEO EN Gas fired condensing boiler SGC 24 SOL User Guide 300017555-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols and abbreviations................................................................................3

More information

>> >> >> High technology with oil. High performance modulating burner Compact boiler design. Compatible with renewable energies. Sustainable Comfort

>> >> >> High technology with oil. High performance modulating burner Compact boiler design. Compatible with renewable energies. Sustainable Comfort Ecodesign by FLOOR-STANDING OIL CONDENSING BOILER ADVANCE High technology with oil >> >> >> High performance modulating burner Compact boiler design Compatible with renewable energies SOLAR SOLID FUEL

More information

GTU C 220 FUEL OIL CONDENSING BOILERS

GTU C 220 FUEL OIL CONDENSING BOILERS GTU C FUEL OIL CONDENSING BOILERS GTU C : fuel oil condensing boilers from to 85 kw for hot water central heating only Heating only (DHW production by independent tank) Condensing boiler Domestic Fuel

More information

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control. product selection data Compact comfort module DHW management possibility Multi zone option control Easy installation Comfort module with two-zone kit Single-zone comfort module Comfort Module Range for

More information

8FUEL OIL CONDENSING BOILERS

8FUEL OIL CONDENSING BOILERS EASYLIFE PROJET GTU (FF) / WINGO SF (FF) GTU 0 GTU 0 FF GTU 00/V GTU 00 FF/V POWER RANGES GTU 0....-. kw... p. 9 GTU 00/V....-. kw... p. 9 GTU 00....-. kw... p. 9 GTU 0 FF....-. kw... p. 9 RESIDENTIAL

More information

AWHP-2 MIT-IN-2 isystem

AWHP-2 MIT-IN-2 isystem HPI EVOLUTION Export EN Air / water heat pump AWHP- MIT-IN- isystem Installation and Service Manual 76637-00-04 Declaration of conformity The device complies with the standard type described in the EG

More information

ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS

ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS ZENA PLUS WALL-HUNG GAS BOILERS MSL FF: from. to 1 kw for heating only MSL FF + BMR 80 and MSL FF + SR 10: from. to 1 kw for heating and DHW produced by an 80-litre calorifier placed beside the boiler,

More information

MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI

MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI Vivadens EN Wall-hung gas condensing boilers MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI User Guide 300015874-001-B Contents 1 Introduction...4 1.1 Used symbols...4 1.2 Abbreviations...4 1.3 General...4

More information

Innovens. Wall-hung gas condensing boilers MCA 25/28 BIC. Installation and Service Manual

Innovens. Wall-hung gas condensing boilers MCA 25/28 BIC. Installation and Service Manual Innovens EN Wall-hung gas condensing boilers MCA 5/8 BIC Installation and Service Manual 300059-00-0 EG declaration of conformity The device complies with the standard type described in the EG declaration

More information

FLOOR-STANDING GAS CONDENSING BOILERS FROM 3.4 TO 35.9KW. by 160 litre enamelled calorifier with coil placed CONDITIONS OF USE HOMOLOGATION

FLOOR-STANDING GAS CONDENSING BOILERS FROM 3.4 TO 35.9KW. by 160 litre enamelled calorifier with coil placed CONDITIONS OF USE HOMOLOGATION FLOOR-STANDING GAS CONDENSING BOILERS FROM.4 TO 5.KW AGC 15-25-5: for heating only AGC /V 100 HL: for heating and DHW production by 100 litre stratification calorifier placed under the boiler AGC /V 0

More information

INSTRUCTION FOR THE USER THC V E OIL BLU

INSTRUCTION FOR THE USER THC V E OIL BLU INSTRUCTION FOR THE THC V E OIL BLU CONTENTS General safety information 4 Precautions 4 Control panel 5 Mode selection 8 User levels 10 Start-up 12 Temporary shutdown 15 Preparing for extended periods

More information

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features Comfort Module Range for Monobloc Heat Pumps Quality Management Systems Comfort module with two-zone kit Single-zone comfort module 8HMA Nominal heating capacity 4- kw Nominal cooling capacity 4- kw The

More information

V. DIFFERENTIAL THERMOSTAT

V. DIFFERENTIAL THERMOSTAT DTC 200/2G DTC 200/2G is a differential thermostat, designed for heating DHWT (domestic hot water tank) from one heating source (solar collectors, boilers, heat pumps) with possibility to control the burner

More information

Quickheat 30 weather compensated boiler control

Quickheat 30 weather compensated boiler control Quickheat 0 weather compensated boiler control A compact and sophisticated heating controller The compact KM controller is designed for the control of fan assisted boilers with modulating burners. The

More information

WALL-HUNG GAS CONDENSING BOILERS MCR-P 24/28 BIC. HOMOLOGATION B 23P - C 13x - C 33x - C 93x -C 53 - C 43x - C 83x *

WALL-HUNG GAS CONDENSING BOILERS MCR-P 24/28 BIC. HOMOLOGATION B 23P - C 13x - C 33x - C 93x -C 53 - C 43x - C 83x * VIVADENS MCR-P WALL-HUNG GAS CONDENSING BOILERS MCR-P 24: from 6.3 to 25.0 kw, for heating only MCR-P 24/BS 80 and MCR-P 24/BS 130: from 6.3 to 25.0 kw, for heating and domestic hot water production by

More information

Instructions for installation and use RE/I. Industrial electric heater for swimming pool

Instructions for installation and use RE/I. Industrial electric heater for swimming pool Instructions for installation and use RE/I Industrial electric heater for swimming pool Réf. : N.D.010.A.EN Ver. 06-2010 1. Installation... 2 1.1 General... 2 1.1.1 Precautions... 2 1.1.2 General terms

More information

NANEO EMC-M EASYLIFE WALL-HUNG GAS CONDENSING BOILERS

NANEO EMC-M EASYLIFE WALL-HUNG GAS CONDENSING BOILERS NANEO EMC-M WALL-HUNG GAS CONDENSING BOILERS EMC-M : from 6.1 to.8 kw, for heating only EMC-M /BS 8 and EMC-M /BS 13: from 6.1 to.8 kw, for heating and hot water preparation by associated DHW tank, 8 or

More information

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER Heating Circuit ZONE Controller RVA 46.531/109 Zonal temperature controller for control of a lowtemperature heating system, for use with condensing gas boilers Instructions for the INSTALLER INDEX Page

More information

Solar station DKP 6-8 / DKP Installation and Service Manual C

Solar station DKP 6-8 / DKP Installation and Service Manual C EN Solar station DKP 6-8 / DKP 9-20 Installation and Service Manual 300014274-001-C Contents 1 Introduction.............................................................................3 1.1 Used symbols...........................................................................................3

More information

C 310 ECO - C 610 ECO

C 310 ECO - C 610 ECO EN Gas fired condensing boiler C 310 ECO - C 610 ECO User Guide 300015183-001-A Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3

More information

Wall-hung gas boilers. Instructions for use. English 31/08/05

Wall-hung gas boilers. Instructions for use. English 31/08/05 City 1.24/II Chimney and VMC - City 1.24/II FF City 2.24/II Chimney and VMC - City 2.24/II FF - City 2.28 FF City 3.24/II Chimney - City 3.24/II FF City 24 BIC/II - City 24 BIC/II FF City Condens 1.24,

More information

Installation, operating and servicing instructions

Installation, operating and servicing instructions English 57-115 - 144-1 - 259 Installation, operating and servicing instructions ITALIA EN 1 ITALIA English INDEX WARnINGS 3 Who should read these instructions 3 Symbols 3 Recommendations 3 Importants notes

More information

INDEPENDENT DOMESTIC CALORIFIERS

INDEPENDENT DOMESTIC CALORIFIERS BPB-BLC /BEPC /B /FWS INDEPENDENT DOMESTIC CALORIFIERS BPB : Performance, independent calorifiers, capacity to litres BLC : Comfort, independent calorifiers, capacity to litres BEPC : DHW calorifier litres

More information

RVL481. Heating Controller. including d.h.w. heating

RVL481. Heating Controller. including d.h.w. heating 2 541 Heating Controller including d.h.w. heating RVL481 Multifunctional and communicating heating controller for use in residential and non-residential buildings. Suited for heating circuit control with

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL INSTALLATION, OPERATION AND MAINTENANCE MANUAL idealtech PRIME CONTROL PANEL For Users Guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured

More information

400 and 700 solar tanks 400 and 700 solar tanks

400 and 700 solar tanks 400 and 700 solar tanks EN Solar calorifiers for combined systems (CSS) 400 and 700 solar tanks 400 and 700 solar tanks Installation, use and maintenance manual 3000 Contents 1 Safety instructions... 3 1.1 General safety instructions...

More information

NANEO EMC-M WALL-HUNG GAS CONDENSING BOILERS

NANEO EMC-M WALL-HUNG GAS CONDENSING BOILERS NANEO EMC-M WALL-HUNG GAS CONDENSING BOILERS EMC-M : from 6.1 to.8 kw, for heating only EMC-M /BS 8 and EMC-M /BS 13: from 6.1 to.8 kw, for heating and hot water preparation by associated DHW tank, 8 or

More information

Pellet boiler Electronic Modulation Automatic Cleaning Grinder system Easy Installation 4 power levels: 10, 16, 25, 43 kw

Pellet boiler Electronic Modulation Automatic Cleaning Grinder system Easy Installation 4 power levels: 10, 16, 25, 43 kw Pellet boiler Electronic Modulation Automatic Cleaning Grinder system Easy Installation 4 power levels: 0, 6, 5, 4 kw CLASS IN EN 0/5 Innovation with meaning BioClass NG IN EN 0/5 CLASS DOMUSA has managed

More information

Fitting & Commissioning Instructions. EcoBlue Combi and System Range. Outdoor Sensor Kit. Kit Part No (System) Kit Part No.

Fitting & Commissioning Instructions. EcoBlue Combi and System Range. Outdoor Sensor Kit. Kit Part No (System) Kit Part No. United Kingdom en Fitting & Commissioning Instructions Outdoor Sensor Kit EcoBlue Combi and System Range Kit Part No. 7214286 (System) Kit Part No. 7213356 (Combi) These instructions should be read in

More information

Modulens G >> >> >> Condensing in excellence mode

Modulens G >> >> >> Condensing in excellence mode Modulens G FLOOR-STNDING GS CONDENSING BOILER Ecodesign by DVNCE Condensing in excellence mode >> >> >> Environmental friendliness and energy savings Maximum domestic hot water comfort Compatible with

More information

EUROFLAT SERIES TYPES C... S... M...

EUROFLAT SERIES TYPES C... S... M... EUROFLAT SERIES TYPES C... S... M... AUTOMATIC CONTROL SYSTEMS FOR GAS BURNERS AND GAS BURNING APPLIANCES WITH OR WITHOUT FAN APPLICATION The electronic systems of this range are suitable to control gas

More information

DOMESTIC HOT WATER Follow operational sequence

DOMESTIC HOT WATER Follow operational sequence DOMESTIC HOT WATER Follow operational sequence Turn Winter/Summer selector to Summer position. The display is switch on. Go to section A Error 110 flashing Error 131 flashing Turn the selector to reset

More information

Installation and Instruction Manual

Installation and Instruction Manual HEATED AIR CURTAIN Installation and Instruction Manual This manual is for Noirot Heated Air Curtains fitted with electronic control boards. For air curtains without electronic control boards please refer

More information

Janfire Pellet Burner Boiler. for single / double burner management (Version 1.1)

Janfire Pellet Burner Boiler. for single / double burner management (Version 1.1) SY325 Janfire Pellet Burner Boiler for single / double burner management (Version 1.1) TECHNICAL DATA SHEET V1.1 rev.12/2007 Contents INTRODUCTION...3 1 THE CONTROL PANEL...4 2 THE KEYS...4 3 THE LEDS...4

More information

PMC-M WALL-HUNG GAS CONDENSING BOILERS

PMC-M WALL-HUNG GAS CONDENSING BOILERS PMC-M WALL-HUNG GAS CONDENSING BOILERS PMC-M : from 6.1 to.8 kw, for heating and hot water preparation by associated DHW tank BMR 8 or SR 13 PMC-M MI: from 6.1 to 35.7 kw, for heating and instant domestic

More information

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission The New Remeha Quinta Pro Range Condensing Boilers REMEHA QUINTA PRO RANGE HIGH EFFICIENCY 110% NCV AT 40/30 C FULLY MODULATING BOILER CONTROL PREMIX BURNER CLEAN COMBUSTION ULTRA LOW NOx BREEAM EXCELLENT

More information

Instruction manual. WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules

Instruction manual. WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules Instruction manual WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules This manual must only be used by a qualified heating installer/service technician.

More information

1 VICTRIX ZEUS Superior kw I features

1 VICTRIX ZEUS Superior kw I features Wall-hung condensing VICTRIX ZEUS Superior kw I is the new range of wall-hung condensing boilers with 54 litre stainless steel storage tank available in two versions with nominal heat output of 26 kw and

More information

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

HYDROCIAT LW R407C. Water cooled chillers USE RANGE Screw compressors CIAT dry direct expansion shell and tubes evaporator HPS equipment (High Power System) cooling or heating Heat recovery ENVIRONMENTALLY HFC R407C PROTECTION DE FRIENDLY L'ENVIRONNEMENT

More information

B 150p to B 500p. Independent domestic hot water tanks. Installation instructions. Instructions for use. Technical instructions.

B 150p to B 500p. Independent domestic hot water tanks. Installation instructions. Instructions for use. Technical instructions. B 150p to B 500p Independent domestic hot water tanks English 25/04/06 Installation instructions Instructions for use Technical instructions 94870007 Contents Introduction.................................................................................3

More information

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45 Plug & Heat heat pump Quick and easy to install For new homes or boiler backup operation 50 HFC R410A CERTIFIED BY CERTITA Heating capacity: 5.5 to 22 kw option CERTIFIED BY CERTITA 30/35-40/45 USE The

More information

FM458/CMC 930. Strategy module. Service instructions. For contractors. Read carefully prior to commissioning or service.

FM458/CMC 930. Strategy module. Service instructions. For contractors. Read carefully prior to commissioning or service. Strategy module FM458/CMC 930 For contractors Read carefully prior to commissioning or service. 6 720 803 196 (2011/06) GB / IE / AU Service instructions 2 1 Safety........................................

More information

STM Department TRAINING MODULE. : instantaneous. Version 1.0, Jan 2006

STM Department TRAINING MODULE. : instantaneous. Version 1.0, Jan 2006 TRAINING MODULE Product group Group Project Name Sales designation Production unit : Wallhung boiler : instantaneous : MX2 COMFORT : : ST BRIEUC (France) Version 1.0, Jan 2006 - 2 - Update VERSION DATE

More information

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc Mikrofill Ethos Condensing combination boiler Maintenance Instructions 24cc IMPORTANT Benchmark Installation, Commissioning and Service Record Log Book is enclosed in your customer information pack. This

More information

BHSAPPMAN 08/00 USA. Applications Manual. Ecomatic / Logamatic Controls. Save These Instructions!

BHSAPPMAN 08/00 USA. Applications Manual. Ecomatic / Logamatic Controls. Save These Instructions! BHSAPPMAN 08/00 USA Applications Manual Ecomatic / Logamatic Controls Save These Instructions! TABLE OF CONTENTS 1 2 3 4 5 6 7 8 Introduction 1 Terms 2-4 Description of Wiring Terminals 5-7 Application

More information

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1........................................................................ 2 2.0 Functional description... 3 3.0 Safety notes... 4 3.1 Safety Notes general............................................

More information

Barrier Washer. Parts. Refer to Page 3 for Model Numbers. BAR17P_

Barrier Washer. Parts. Refer to Page 3 for Model Numbers.  BAR17P_ Barrier Washer Refer to Page 3 for Model Numbers Parts BAR17P_1300622 www.alliancelaundry.com Part No. 1300622R4 November 2014 Table of Contents Title Page Parts Ordering Information... 2 Serial Plate

More information

E V1. System Manager Installation Manual

E V1. System Manager Installation Manual E8.5064 V1 System Manager Installation Manual Please observe the safety instructions and read through this manual carefully before commissioning the equipment. Safety information General information General

More information

KIT UNITÀ AMBIENTE E INTERFACCIA A LED KIT ROOM UNIT AND LED INTERFACE RAUMGERÄT UND LED-SCHNITTSTELLE KIT APPAREIL D'AMBIANCE ET INTERFACE À LEDS

KIT UNITÀ AMBIENTE E INTERFACCIA A LED KIT ROOM UNIT AND LED INTERFACE RAUMGERÄT UND LED-SCHNITTSTELLE KIT APPAREIL D'AMBIANCE ET INTERFACE À LEDS A it KIT UNITÀ AMBIENTE E INTERFACCIA A LED PER IL CONTROLLO DELLA TEMPERATURA AMBIENTE DEL LOCALE en KIT ROOM UNIT AND LED INTERFACE ROOM TEMPERATURE CONTROL ACCESSORY de RAUMGERÄT UND LED-SCHNITTSTELLE

More information

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE Release January 2001 CONTENTS 1.0 GENERAL CHARACTERISTICS... 4 1.1 MAIN CHARACTERIS TICS... 4 2.0 USER INTERFACE (CODE C5121230)... 5 2.1 DISPLAY... 5 2.2 MEANING OF THE LEDS...

More information

HT V2 HT Split

HT V2 HT Split Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single

More information

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E Instantaneous wall-hung with open chamber boilers Small wall-mounted open chamber, conventional flue instant boiler. General features. is a wall-mounted, open combustion chamber, conventional flue generator

More information

P5253 JS F Mertzwiller N IT /02/2013

P5253 JS F Mertzwiller N IT /02/2013 T Technical Sales Documentation Department Technical information Heading No 5 Wall-hung gas condensing boilers NANEO EMC... - PMC... Service tool / After Sales Service information Package HR83 (option)

More information

MINOR 11. * _rev.1* Installation and User Guide. Electronic thermostat for underfloor heating or radiant ceiling heating

MINOR 11. * _rev.1* Installation and User Guide. Electronic thermostat for underfloor heating or radiant ceiling heating Installation and User Guide MINOR 11 Electronic thermostat for underfloor heating or radiant ceiling heating DELTA DORE - Bonnemain 35270 COMBOURG - FRANCE E-mail : deltadore@deltadore.com Device compliant

More information

VIESMANN. Service instructions VITOCELL 300-B VITOCELL 300-V. for contractors

VIESMANN. Service instructions VITOCELL 300-B VITOCELL 300-V. for contractors Service instructions for contractors VIESMANN Vitocell 300-B Type EVB DHW cylinder, 300 and 500 l Vitocell 300-V Type EVI DHW cylinder, 200 to 500 l For applicability, see the last page VITOCELL 300-B

More information

installation and servicing

installation and servicing installation and servicing Falcon GTE Your Ideal installation and servicing guide GTE, GTE 5, GTE 6, GTE 7 & GTE 8 986-0A When replacing any part on this appliance, use only spare parts that you can be

More information

Solar Thermal Energy

Solar Thermal Energy Solar Thermal Energy INDEX Residential Applications Flat Plate Solar Collectors... 5 SOL 200 and SOL 200 H... 7 Mediterráneo 200... 8 Mediterráneo SLIM 200... 9 Hydraulic fittings and mounting systems...

More information

Service booklet for the Engineer for Gas Condensing Boilers

Service booklet for the Engineer for Gas Condensing Boilers Service booklet for the Engineer for Gas Condensing Boilers 6 720 610 577-00.10 ZWB 7-29 CC1 GC-Number: 47 108 05 ZB 7-28 CS1 GC-Number: 41 108 02 ZWB 7-27 HE combi GC-Number: 47 311 55 ZWB 7-25 HE combi

More information

TERMO-Blok TERMO-Extra TERMO-Blok PTV TERMO-Mini

TERMO-Blok TERMO-Extra TERMO-Blok PTV TERMO-Mini ELECTRIC BOILERS FOR CENTRAL HEATING TERMO-Blok TERMO-Extra TERMO-Blok PTV TERMO-Mini INSTRUCTIONS FOR INSTALLATION INSTRUCTIONS FOR INSTALLATION We reserve the right of alternations TMS-UT-0114-T01-4

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information