1 EN Regulation isense Pro DIN - AD80 C00695-A Installation and Service Manual

2 Contents Introduction...4. Symbols used...4. Abbreviations General Manufacturer s liability Installer s liability Certifications...5 Safety instructions and recommendations...6. Recommendations Technical description Description of the keys Description of the display Key functions Flame symbol Solar (If connected) Operating modes Domestic Hot Water override Other information Technical specifications Installation Package list Installing the outside sensor Choice of the location Connecting the outside sensor Mounting and connecting the module Boiler GAS 0 ECO PRO Boiler GAS 30 ECO Boiler GAS 30 ECO PRO Electrical connections Recommendations Description of the connection terminal block Connecting the BUS cable Connecting a heating circuit Connecting a heating circuit and a domestic hot water tank...0 //

3 Contents Connecting two circuits and a domestic hot water tank Connecting a direct circuit, a valve circuit and a DHW tank Hot water storage tank connection Pool connection Connecting a mixed tank Connecting the options Connection in cascade Electrical connection diagram Operating the appliance Powering up for the first time Access to the various browsing levels User level After Sales level Browsing in the menus Reading out measured values Settings after powering up for the first time Displaying the parameters in extended mode Setting the parameters specific to the installation Naming the circuits and generators Setting the heating curve Changing the settings Language selection Defining the configuration mode Calibrating the sensors Professional settings Configuring the network Return to the factory settings...56 //

4 6 Switching off the appliance Installation shutdown Antifreeze protection Troubleshooting Installer s contact details Messages (type code Mxx) Message history Faults Deletion of sensors from the memory in the PCB Failure history Parameter and input/output check (mode tests) Spare parts General Spare parts //

5 isense Pro DIN - AD80. Introduction Introduction. Symbols used In these instructions, various danger levels are employed to draw the user s attention to particular information. In so doing, we wish to safeguard the user s safety, obviate hazards and guarantee correct operation of the appliance. DANGER Risk of a dangerous situation causing serious physical injury. WARNING Risk of a dangerous situation causing slight physical injury. CAUTION Risk of material damage. Signals important information. ¼Signals a referral to other instructions or other pages in the instructions.. Abbreviations 4 DHW: Domestic hot water 4 3WV: 3-way valve.3 General.3.. Manufacturer s liability Our products are manufactured in compliance with the requirements of the various applicable European Directives. They are therefore delivered with [ marking and all relevant documentation. //

6 . Introduction isense Pro DIN - AD80 In the interest of customers, we are continuously endeavouring to make improvements in product quality. All the specifications stated in this document are therefore subject to change without notice. Our liability as the manufacturer may not be invoked in the following cases: 4 Failure to abide by the instructions on using the appliance. 4 Faulty or insufficient maintenance of the appliance. 4 Failure to abide by the instructions on installing the appliance..3.. Installer s liability The installer is responsible for the installation and inital start up of the appliance. The installer must respect the following instructions: 4 Read and follow the instructions given in the manuals provided with the appliance. 4 Carry out installation in compliance with the prevailing legislation and standards. 4 Perform the initial start up and carry out any checks necessary. 4 Explain the installation to the user. 4 If a maintenance is necessary, warn the user of the obligation to check the appliance and maintain it in good working order. 4 Give all the instruction manuals to the user..4 Certifications This product complies to the requirements to the european directives and following standards: 4 006/95/EC Low Voltage Directive. Reference Standard: EN /08/EC Electromagnetic Compatibility Directive. Generic standards: EN , EN //

7 isense Pro DIN - AD80. Safety instructions and recommendations Safety instructions and recommendations. Recommendations WARNING Only qualified professionals are authorised to work on the appliance and the installation. The appliance should be on Summer or Antrifreeze mode rather than switched off to guarantee the following functions: 4 Anti blocking of pumps. 4 Antifreeze protection. //

8 3. Technical description isense Pro DIN - AD80 3 Technical description 3. Description of the keys A A A B bar AUTO C D E F A B C D E F Temperature setting key (heating, DHW, swimming pool) Operating mode selection key DHW override key Key to access the parameters reserved for the installer Keys on which the function varies as and when selections are made Rotary setting button: 4 Turn the rotary button to scroll through the menus or modify a value 4 Press the rotary button to access the selected menu or confirm a value modification 7 //

9 3. Description of the display 3... Key functions > Access to the various menus ( Used to scroll through the menus Used to scroll through the parameters isense Pro DIN - AD80 3. Technical description bar AUTO C00696-A? The symbol is displayed when help is available f b Used to display the curve of the parameter selected Reset of the time programmes Selection of comfort mode or selection of the days to be programmed v Selection of reduced mode or deselection of the days to be programmed j Back to the previous level ESC Back to the previous level without saving the modifications made 3... Flame symbol 4 The symbol is displayed: The burner is operating The symbol is not displayed: The burner is off. bar AUTO C0070-B Solar (If connected) u L00000-A The solar load pump is running The top part of the tank is reheated to the tank set point bar AUTO L00097-A L0000-A L00098-A The entire tank is reheated to the tank set point The entire tank is reheated to the solar tank set point L00099-A The tank is not loaded - Presence of the solar control system //

10 3..4. Operating modes p b Summer mode: The heating is off. Domestic hot water continues to be produced WINTER mode: Heating and domestic hot water working bar AUTO C00697-B AUTO Operation in automatic mode according to the timer programme x Comfort mode: The symbol is displayed when a DAY override (comfort) is activated bar AUTO 3. Technical description isense Pro DIN - AD80 C00698-B m 4 Flashing symbol: Temporary override 4 Steady symbol: Permanent override Reduced mode: The symbol is displayed when a NIGHT override (reduced) is activated 4 Flashing symbol: Temporary override 4 Steady symbol: Permanent override g Holiday mode: The symbol is displayed when a HOLIDAY override (antifreeze) is activated 4 Flashing symbol: Holiday mode programmed 4 Steady symbol: Holiday mode active m Manual mode Domestic Hot Water override A bar is displayed when a DHW override is activated: 4 Flashing bar: Temporary override 4 Steady bar: Permanent override bar AUTO C00707-A 9 //

11 isense Pro DIN - AD80 3. Technical description Other information r The symbol is displayed when domestic hot water production is running. w Valve indicator: The symbol is displayed when a 3-way valve is connected. bar AUTO C00699-B M 4 x: 3-way valve opens 4 c: 3-way valve closes The symbol is displayed when the pump is operating. Name of the circuit for which the parameters are displayed. 3.3 Technical specifications Electricity supply: 30 V - 50 Hz Outside sensor Temperature in C Resistance in Ω Specifications of the flow sensor circuit B + C Specifications of the DHW sensor Specifications of the system sensor Temperature in C Resistance in Ω //

12 4. Installation isense Pro DIN - AD80 4 Installation 4. Package list The delivery includes: 4 The isense Pro DIN module 4 Electrical harness 4 Extension cable marked K (Useful depending on the control panels) 4 Outside sensor 4 Flow sensor (x) 4 DHW sensor 4 Earth terminal block + screws 4 Installation and Service Manual 4 User Guide. 4. Installing the outside sensor 4... Choice of the location It is important to select a place that allows the sensor to measure the outside conditions correctly and effectively. Advised positions: 4 on one face of the area to be heated, on the north if possible 4 half way up the wall in the room to be heated 4 under the influence of meteorological variations 4 protected from direct sunlight 4 easy to access //

13 isense Pro DIN - AD80 4. Installation A B H Z Recommended position Possible position Inhabited height controlled by the sensor Inhabited area controlled by the sensor 8800N00-C Positions to be avoided: 4 masked by a building element (balcony, roof, etc.) 4 close to a disruptive heat source (sun, chimney, ventilation grid, etc.) 8800N00-C 4... Connecting the outside sensor Mount the sensor using the screws and dowels provided. A Z Inserts Ø4 wood screw ¼For the connection of the outside temperature sensor, refer to the chapter "Electrical Connections". 8800N003-C //

14 bar 4. Installation isense Pro DIN - AD Mounting and connecting the module Boiler GAS 0 ECO PRO 4x 4x 3 x C0033-B K K K OT K 3 AUTO 3 4 C0033-B CAUTION Step 3: Connect the extension cable K between connectors A and Z. 3 //

15 isense Pro DIN - AD80 4. Installation Boiler GAS 30 ECO C00333-A 4 C00334-B C00335-A //

16 4. Installation isense Pro DIN - AD80 K K K X6 7 8 C00336-A K 9 0 C00337-C X 6 X 6 C00338-B 5 //

17 isense Pro DIN - AD80 4. Installation 3 4 C00339-B X3 X4 X X Boiler GAS 30 ECO PRO 6 C00330-B 3 4 4x M0097-A //

18 bar 4. Installation isense Pro DIN - AD80 X 3 M00973-B X K K OT OT OT 4 5 M00974-B X4 X3 X AUTO X 6 M00975-A 7 //

19 isense Pro DIN - AD80 4. Installation 4.4 Electrical connections Recommendations WARNING 4 Only qualified professionnals may carry out electrical connections, always with the power off. 4 The boiler is entirely pre-wired. Do not modify the connections inside the control panel. 4 Earth the appliance before making any electrical connections. Make the electrical connections of the boiler according to: 4 The instructions of the prevailing standards. 4 The instructions on the electrical diagrams provided with the boiler. 4 The recommendations in the instructions. CAUTION Separate the sensor cables from the 30 V cables Description of the connection terminal block + 0V 0-0V AF N N C B M Syst. B BF L N N L L N L N C B AUX A B C CDI B/ CDR CDI C Bus M0084-B //

20 4. Installation isense Pro DIN - AD80 * Not connected 0-0 V Inlet 0-0 Volts voice remote monitoring module - Package AD5 A C 3 way valve circuit C I AF Outside sensor - Package FM46 Outside radio-controlled temperature sensor - Package AD5 A B 3 way valve circuit B r BF DHW sensor - Package AD L C Heating pump circuit C Syst. System sensor - Package AD50 L B Heating pump circuit B kc B Outlet sensor circuit B - Package AD99 L AUX Auxiliary pump kc C Outlet sensor circuit C - Package AD99 Lr D.H.W. load pump CDI B / CDR Remote control (Circuit B) - Package AD58 Radio remote control - Circuit B/C - Package AD56 CDI C O Bus Remote control (Circuit C) - Package AD58 Connecting the BUS cascade BUS cable - Package AD4 / AD34 / DB Connecting the BUS cable To connect a cable with mini-din connector to the terminal block, proceed as follows: + 0V A B 0-0V AF Syst. B C CDI B/ CDR CDI C Bus BF B E C A D M00853-B A Braided shield (Terminal 0V) B Brown wire (Terminal 0V) C Green wire (DO NOT USE) D White wire (Terminal B) E Yellow wire (Terminal A) Connecting a heating circuit C B C B AUX 0-0V S Syst. BUS N N N L N L N L N L +OV AF BF B C BA C0085-B A Z E R 3 way valve circuit B Heating pump circuit B Outlet sensor circuit B Heating circuit B 9 //

21 isense Pro DIN - AD80 4. Installation T Y Outside sensor Boiler Earth the various pumps and 3-way valves. Settings to be made for this type of installation Parameters Access Settings to be made See chapter CIRC.CURVE B MAX. CIRC. B Menu #SECONDARY INSTAL.P Menu #SECONDARY LIMITS To be customised ¼ "Setting the heating curve", page 4 To be customised ¼ "Professional settings", page Connecting a heating circuit and a domestic hot water tank C B C B AUX 0-0V S Syst. N N N L N L N L N L + OV AF BF 5 B C BUS BA C0086-B A Z E R T Y U I O 3 way valve circuit B Heating pump circuit B Outlet sensor circuit B Heating circuit B Outside sensor Boiler DHW storage tank DHW sensor Domestic circulation loop pump (Optional) //

22 4. Installation isense Pro DIN - AD80 P D.H.W. load pump Earth the various pumps and 3-way valves. Settings to be made for this type of installation Parameters Access Settings to be made See chapter CIRC.CURVE B MAX. CIRC. B Menu #SECONDARY INSTAL.P Menu #SECONDARY LIMITS To be customised ¼ "Setting the heating curve", page 4 To be customised ¼ "Professional settings", page Connecting two circuits and a domestic hot water tank C B C B AUX 0-0V S Syst. N N N L N L N L N L + OV AF BF 5 B C BUS BA C0087-B A Z E R T Y U I O P a z e 3 way valve circuit B Heating pump circuit B Outlet sensor circuit B Heating circuit B Outside sensor Boiler DHW storage tank DHW sensor Domestic circulation loop pump (Optional) D.H.W. load pump 3 way valve circuit C Heating pump circuit C Outlet sensor circuit C //

23 isense Pro DIN - AD80 4. Installation r Heating circuit C Earth the various pumps and 3-way valves. Settings to be made for this type of installation Parameters Access Settings to be made See chapter INSTALLATION CIRC.CURVE B MAX. CIRC. B CIRC.CURVE C MAX. CIRC. C Menu #SYSTEM Menu #SECONDARY INSTAL.P Menu #SECONDARY LIMITS Menu #SECONDARY INSTAL.P Menu #SECONDARY LIMITS EXTENDED ¼ "Displaying the parameters in extended mode", page 38 To be customised ¼ "Setting the heating curve", page 4 To be customised ¼ "Professional settings", page 46 To be customised ¼ "Setting the heating curve", page 4 To be customised ¼ "Professional settings", page Connecting a direct circuit, a valve circuit and a DHW tank C B C B AUX 0-0V S Syst. N N N L N L N L N L + OV AF BF 5 B C BUS BA C00336-C A Z E R T Y U I 3 way valve circuit B Heating pump circuit B Outlet sensor circuit B Heating circuit B Outside sensor Boiler DHW storage tank DHW sensor //

24 4. Installation isense Pro DIN - AD80 O P a z Domestic circulation loop pump (Optional) D.H.W. load pump Heating pump circuit C Heating circuit C Earth the various pumps and 3-way valves. Settings to be made for this type of installation Parameters Access Settings to be made See chapter INSTALLATION CIRC.CURVE B MAX. CIRC. B If circuit C is a direct circuit without a flow sensor: CIRC. C: () CIRC.CURVE C Menu #SYSTEM Menu #SECONDARY INSTAL.P Menu #SECONDARY LIMITS Menu #SYSTEM Menu #SECONDARY INSTAL.P EXTENDED To be customised To be customised DIRECT To be customised () The parameter is only displayed if INSTALLATION parameter is set to EXTENDED. ¼ "Displaying the parameters in extended mode", page 38 ¼ "Setting the heating curve", page 4 ¼ "Professional settings", page 46 ¼ "Setting the parameters specific to the installation", page 38 ¼ "Setting the heating curve", page Hot water storage tank connection QUADRO DU storage tank In this installation example, the storage tank (type QUADRO DU) incorporates a domestic hot water zone. The boiler starts up systematically to maintain the domestic hot water zone in the storage tank or to maintain the independent tank at temperature. 3 //

25 isense Pro DIN - AD80 4. Installation C B C B AUX 0-0V S Syst. N N N L N L N L N L + OV AF BF B C BUS BA C0088-C M 5 A Z E R T Y U Boiler regulator This type of installation only works if the boiler incorporates a boiler pump managed by the boiler regulator. Connect the heating pump (Circuit B). DHW sensor Connect the sensor from the storage tank (Package AD50). Buffer tank. Solar sensor probe. Connect the solar station to the solar collectors. Settings to be made for this type of installation Parameters Access Settings to be made See chapter INSTALLATION I.SYST If circuit B is a direct circuit without a flow sensor: CIRC. B: () Menu #SYSTEM Menu #SYSTEMEME} Menu #SYSTEM EXTENDED STORAGE TANK DIRECT () The parameter is only displayed if INSTALLATION parameter is set to EXTENDED. ¼ "Displaying the parameters in extended mode", page 38 ¼ "Setting the parameters specific to the installation", page 38 //

26 4. Installation isense Pro DIN - AD80 The DHW part is maintained at the DHW set point by the boiler. The heating zone is maintained at the set temperature calculated according to the outside temperature. The zone is reheated when the heating buffer temperature sensor T falls -6 C below the calculated set temperature. Reheating in the heating zone stops when the heating buffer temperature rises above the calculated set temperature Pool connection C B C B AUX 0-0V S Syst. N N N L N L N L N L + OV AF BF 4 B C BUS BA C0089-C 3 5 A Z E R T Connect the secondary swimming pool pump. Connect the swimming pool sensor. Plate heat exchanger. Pool heating cut-off control When the parameter I.TEL: is on 0/ B, the swimming pool is no longer heated when the contact is open (factory setting), only the antifreeze continues to be active. The contact direction can still be adjusted by the parameter CT.TEL. Connect the primary swimming pool pump. 5 //

27 isense Pro DIN - AD80 4. Installation Settings to be made for this type of installation Parameters Access Settings to be made See chapter INSTALLATION MAX. CIRC. B CIRC. B: () If a heating shutdown command is connected to the 0-0V inlet on the terminal block: IN 0-0V If a heating shutdown command is connected to the 0-0V inlet on the terminal block: I.TEL: () Menu #SYSTEM Menu #SECONDARY LIMITS Menu #SYSTEM Menu #SYSTEM Menu #SYSTEM EXTENDED Set the value of MAX. CIRC. B to the temperature corresponding to the needs of the exchanger SWIM.P. NO 0/ B () The parameter is only displayed if INSTALLATION parameter is set to EXTENDED. () The parameter is only displayed if the parameter IN 0-0V is set to OFF. ¼ "Displaying the parameters in extended mode", page 38 ¼ "Professional settings", page 46 ¼ "Setting the parameters specific to the installation", page 38 Controlling the pool circuit The control system can be used to manage a swimming pool circuit in both cases: Case : The control system regulates the primary circuit (boiler/ exchanger) and the secondary circuit (exchanger/pool). 4 Connect the primary circuit pump (boiler/exchanger) to the pump B outlet. The temperature MAX. CIRC. B is then guaranteed during comfort periods on programme B in summer and winter alike. 4 Connect the pool sensor (package AD) to the S OUTL B input. 4 Set the set point of the pool sensor using key C in the range 5-39 C. Case : The pool has already a regulation system that is to be kept. The control system only regulates the primary circuit (boiler/exchanger). 4 Connect the primary circuit pump (boiler/exchanger) to the pump B outlet. The temperature MAX. CIRC. B is then guaranteed during comfort periods on programme B in summer and winter alike. The swimming pool can also be connected to circuit C by adding the AD49 option: 4 Make the connection to the terminal blocks marked C. 4 Set the parameters for circuit C. //

28 4. Installation isense Pro DIN - AD80 Hourly programming of the secondary circuit pump The secondary pump operates during programme B comfort periods in summer and winter alike. Stopping To prepare your pool for winter, consult your pool specialist Connecting a mixed tank C B C B AUX 0-0V S Syst. N N N L N L N L N L + OV AF BF B C CDI CDR B BUS CDI B A C C0080-B A Z E R T Y Connect the electric tank Power control relay to the electrical resistor DHW sensor D.H.W. load pump Connect the outside temperature sensor Boiler Settings to be made for this type of installation Parameters Access Settings to be made See chapter INSTALLATION S.AUX: () Menu #SYSTEM Menu #SYSTEM EXTENDED DHW ELEC () The parameter is only displayed if INSTALLATION parameter is set to EXTENDED. ¼ "Displaying the parameters in extended mode", page 38 ¼ "Setting the parameters specific to the installation", page Connecting the options For example: TELCOM remote vocal monitoring module, remote controls for circuits B and C, second DHW tank 7 //

29 TELCOM AL AL PRG 3 ALP # V V SET isense Pro DIN - AD80 4. Installation C B C B AUX 0-0V S Syst. N N N L N L N L N L + OV AF BF B C CDI CDR B CDI C BUS B A MODE MODE C008-C Z E R Y U I Connect the load pump of the second tank. Second domestic hot water tank. Connect the DHW sensor of the second tank. Connect the TELCOM remote vocal monitoring module. (depending on its availability in your country). Connecting the BUS cascade, VM. Use a shielded cable connected on each side of the earth. Connect the remote control (Package AD58/FM5). Settings to be made for this type of installation Parameters Access Settings to be made See chapter INSTALLATION If second tank connected: S.AUX: () If a remote monitoring module is connected to the 0-0V inlet on the terminal block: IN 0-0V If a remote monitoring module is connected to the 0-0V inlet on the terminal block: I.TEL: () I.SYST CTC.I.SYST Menu #SYSTEM Menu #SYSTEM Menu #SYSTEM Menu #SYSTEM Menu #SYSTEM Menu #SYSTEM EXTENDED DHW NO ANTIFR To be customised To be customised () The parameter is only displayed if INSTALLATION parameter is set to EXTENDED. () The parameter is only displayed if the parameter IN 0-0V is set to OFF. ¼ "Displaying the parameters in extended mode", page 38 ¼ "Setting the parameters specific to the installation", page 38 //

30 4. Installation isense Pro DIN - AD Connection in cascade DHW tank after the mixing tank C008-B 7 A Z E R T Y U I Master boiler Secondary boiler Secondary boiler D.H.W. load pump DHW sensor Cable BUS Low loss header Cascade outlet sensor Connect the sensor to the terminal block E.SYST on the master boiler. Settings to be made for this type of installation: Master boiler Parameters Access Settings to be made See chapter INSTALLATION CASCADE: () MASTER CONTROLLER () SYSTEM NETWORK () Menu #SYSTEM Menu #NETWORK Menu #SYSTEM Menu #SYSTEM EXTENDED ON ON ADD GENE MANU () The parameter is only displayed if INSTALLATION parameter is set to EXTENDED ¼ "Displaying the parameters in extended mode", page 38 ¼ "Configuring the network", page 53 9 //

31 isense Pro DIN - AD80 4. Installation Settings to be made for this type of installation: Follower boilers Parameters Access Settings to be made See chapter INSTALLATION CASCADE: () MASTER CONTROLLER () SLAVE NUMBER () Menu #SYSTEM Menu #NETWORK Menu #SYSTEM Menu #SYSTEM EXTENDED ON OFF, 3,... () The parameter is only displayed if INSTALLATION parameter is set to EXTENDED ¼ "Displaying the parameters in extended mode", page 38 ¼ "Configuring the network", page 53 Cascade of one boiler equipped with isense Pro DIN and one boiler equipped with an OTH Modbus interface board DIN N C B C B AUX 0-0V S Syst. N N N L N L N L N L + OV AF BF B C CDI CDR B CDI C BUS B A 6 K 7 BUS OT OT N N M00747-D A Z E R T Y U I O P a z e Master boiler equipped with a OpenTherm control panel Secondary boiler Low loss header BUS cable to make the link between boilers 3 way valve circuit B Heating pump circuit B Outlet sensor circuit B Heating circuit B 3 way valve circuit C Heating pump circuit C Outlet sensor circuit C Heating circuit C D.H.W. load pump DHW sensor //

32 4. Installation isense Pro DIN - AD80 r t y u i DHW storage tank Domestic circulation loop pump (Optional) Outside sensor (Optional) OTH Modbus interface board (Package AD86 / AD87) System sensor Connect a safety thermostat if the heating circuit is for underfloor heating. Settings to be made for this type of installation: isense Pro DIN master module Parameters Access Settings to be made See chapter INSTALLATION CASCADE: () MASTER CONTROLLER () SYSTEM NETWORK () PERMUT Menu #SYSTEM Menu #NETWORK Menu #SYSTEM Menu #SYSTEM EXTENDED ON ON ADD SLAVE () The parameter is only displayed if INSTALLATION parameter is set to EXTENDED ¼ "Displaying the parameters in extended mode", page 38 ¼ "Configuring the network", page 53 Settings to be made for this type of installation: isense Pro DIN slave module ¼Refer to the manual delivered with package AD86 / AD87 Connecting times valve circuits and DHW tanks DIN N DIN N C B C B AUX 0-0V S Syst. N N N L N L N L N L + OV AF BF B C BUS B A C B C B AUX 0-0V S Syst. N N N L N L N L N L + OV AF BF B C C00337-D BUS B A 7 4 N N DHW priority is activated on all of the system s secondary circuits. A Z Master boiler Secondary boiler 3 //

33 isense Pro DIN - AD80 4. Installation E R T Y U I O P a z e r t y u i Low loss header BUS cable to make the link between boilers 3 way valve circuit B Heating pump circuit B Outlet sensor circuit B Heating circuit B 3 way valve circuit C Heating pump circuit C Outlet sensor circuit C Heating circuit C D.H.W. load pump DHW sensor DHW storage tank Domestic circulation loop pump (Optional) Outside sensor System sensor Settings to be made for this type of installation: Master boiler Parameters Access Settings to be made See chapter INSTALLATION CASCADE: () MASTER CONTROLLER () SYSTEM NETWORK () Menu #SYSTEM Menu #NETWORK Menu #SYSTEM Menu #SYSTEM EXTENDED ON ON ADD GENE MANU () The parameter is only displayed if INSTALLATION parameter is set to EXTENDED ¼ "Displaying the parameters in extended mode", page 38 ¼ "Configuring the network", page 53 Settings to be made for this type of installation: Follower boilers Parameters Access Settings to be made See chapter INSTALLATION CASCADE: () MASTER CONTROLLER () SLAVE NUMBER () Menu #SYSTEM Menu #NETWORK Menu #SYSTEM Menu #SYSTEM EXTENDED ON OFF, 3,... () The parameter is only displayed if INSTALLATION parameter is set to EXTENDED ¼ "Displaying the parameters in extended mode", page 38 ¼ "Configuring the network", page 53 //

34 4. Installation isense Pro DIN - AD Electrical connection diagram K X 30V 30V 30V X3 X4 K X N N C B 36 M 9 N L 3 30V L N N L L N L N C B AUX V 0-0V AF BF Syst. B C CDI B/ CDR CDI C A B Bus C A 33 //

35 isense Pro DIN - AD80 5. Operating the appliance 5 Operating the appliance 5. Powering up for the first time bar LANGUE FRANCAIS Français - Deutsch - English - Italiano - Espanol - Nederlands - Pycck - Polski - Türk -. The first time the boiler is powered up, the LANGUAGE menu is displayed. Select the desired language by turning the rotary button.. To confirm, press the rotary button. 3. Set parameter CONFIGURATION. Select OTH+3WV by turning the rotary button and press to confirm: C0086-C Setting VM/MR 3WV+ 0/+V3V OTH+3WV Description Do not select this setting Do not select this setting Do not select this setting Control for a generator by BUS OpenTherm 4. To confirm, press the rotary button. 5. Access to the various browsing levels 5... User level The information and settings in the User level can be accessed by everyone.. Press the > key. bar AUTO SUNDAY :45 C009-D-04 //

36 5. Operating the appliance isense Pro DIN - AD The information and settings in the can be accessed by experienced people.. Press the > key. bar AUTO SUNDAY : AUTO TEMP.: 68 SUNDAY :45 C009-D-04. Press the - key. It is also possible to access the installer level by pressing only the - key for around 5 seconds. C007-F After Sales level The After Sales Service information and settings can be accessed by the professional providing the After Sales Service.. Press the > key. bar AUTO SUNDAY : AUTO TEMP.: 68 SUNDAY :45 C009-D-04. Press key - for around 5 seconds. It is also possible to access the After Sales level by pressing only the - key for around 0 seconds. 5" C0035-F //

37 isense Pro DIN - AD80 5. Operating the appliance 5.3 Browsing in the menus bar #MEASURES #CHOICE TIME PROG. #TIME PROGRAM #SETTING #TIME.DAY AUTO. To select the desired menu, turn the rotary button.. To access the menu, press the rotary button. To go back to the previous display, press the key j. bar CURRENT PROG.B CURRENT PROG.C AUTO P P3 C000-B To select the desired parameter, turn the rotary button. 4. To modify the parameter, press the rotary button. To go back to the previous display, press the key j. bar CURRENT PROG.C "Choice of the timeprogram applied C" AUTO P4 C00-C To modify the parameter, turn the rotary button. 6. To confirm, press the rotary button. To cancel, press key h. C00-C To go back to the main display, press key j times. bar AUTO LUNDI :45 x It is possible to use the ( and keys instead of the rotary button. C004-D-04 //

38 5. Operating the appliance isense Pro DIN - AD Reading out measured values The various values measured by the appliance are displayed in the #MEASURES menu. bar AUTO SUNDAY :45. To access user level: Press the > key.. Select the menu #MEASURES. 4 Turn the rotary button to scroll through the menus or modify a value. 4 Press the rotary button to access the selected menu or confirm a value modification. ¼For a detailed explanation of menu browsing, refer to the chapter: "Browsing in the menus", page 36. C009-D-04 User level - #MEASURES menu Parameter Description Unit OUTSIDE TEMP. Outside temperature C ROOMTEMP. B () Room temperature of circuit B C ROOMTEMP. C () Room temperature of circuit C C BOILER TEMP. () Water temperature in the boiler C WATER TEMP. () Water temperature in the DHW tank C STOR.TANK.TEMP () SWIMMING P.T.B () SWIMMING P.T.C () OUTLET TEMP. B () OUTLET TEMP. C () Water temperature in the storage tank C Water temperature of the swimming pool on circuit B C Water temperature of the swimming pool on circuit C C Temperature of the flow water in circuit B C Temperature of the flow water in circuit C C SYSTEM TEMP. () Temperature of the system flow water if multi-generator C T.DHW BOTTOM () TEMP.TANK AUX () TEMP.SOL.TANK ()() SOLAR.COLL.T. () () SOLA.ENERGY () () Water temperature in the bottom of the DHW tank C Water temperature in the second DHW tank connected to the AUX circuit C Temperature of the hot water produced by solar power (TS) C Solar panel temperature (TC) C Solar energy accumulated in the tank IN 0-0V ()() Voltage at input 0-0 V V CTRL Software control number () The parameter is only displayed for the options, circuits or sensors actually connected. () According to the configuration kwh 37 //

39 isense Pro DIN - AD80 5. Operating the appliance 5.5 Settings after powering up for the first time Displaying the parameters in extended mode AUTO TEMP.: 68 5" SUNDAY :45 The display mode on the control panel is set as standard in such a way as only to show the conventional parameters. It is possible to switch to extended mode by proceeding as follows:. Access the installer level: Press key - for around 5 seconds.. Select the menu #SYSTEM. 4 Turn the rotary button to scroll through the menus or modify a value. 4 Press the rotary button to access the selected menu or confirm a value modification. ¼For a detailed explanation of menu browsing, refer to the chapter: "Browsing in the menus", page Set parameter INSTALLATION to EXTENDED. C0035-F-04 - Menu #SYSTEM Parameter Adjustment range Description Factory setting Customer setting INSTALLATION CLASSIC Displays the parameters of a conventional installation EXTENDED Displays all parameters CLASSIC Regardless of what is done to the keys, the regulator switches back to CLASSIC mode after 30 minutes Setting the parameters specific to the installation AUTO TEMP.: 68 5" SUNDAY :45 C0035-F-04. Access the installer level: Press key - for around 5 seconds.. Select the menu #SYSTEM. 4 Turn the rotary button to scroll through the menus or modify a value. 4 Press the rotary button to access the selected menu or confirm a value modification. ¼For a detailed explanation of menu browsing, refer to the chapter: "Browsing in the menus", page Set the following parameters according to the connections made to the PCBs: //

40 5. Operating the appliance isense Pro DIN - AD80 - #SYSTEM menu Parameter Adjustment range Description Factory setting Customer setting CIRC. B: () 3WV Connecting a circuit with 3-way valve ( For example: Underfloor heating) SWIM.P. DIRECT Using the circuit for pool management Use of circuit in direct heating circuit Check and set the heating curve if necessary. See chapter: ¼ "Setting the heating curve", page 4 CIRC. C: () 3WV Connecting a circuit with 3-way valve (For example: Underfloor heating) SWIM.P. DIRECT Using the circuit for pool management Use of circuit in direct heating circuit Check and set the heating curve if necessary. See chapter: ¼ "Setting the heating curve", page 4 S.AUX: () DHW LOOP Use as a domestic loop pump DHW LOOP PROGRAM. Use as an independent programmable outlet PRIMARY PUMP DHW FAILURE DHW ELEC The outlet MAUX is active if a heating demand is present on the secondary pump Use of primary circuit of second DHW tank The outlet MAUX is active if an fault is detected Used to control the electrical resistor according to the timer programme on circuit AUX in summer mode. CTC.I.SYST () CLOSE See table below. CLOSE OPEN I.SYST () SYSTEM () The inlet sensor is used to connect the common flow sensor of a cascade system STORAGE TANK () DHW STRAT ()(3) ST.TANK+DHW () ANTIFR Hot water storage tank affected to heating only Using the DHW tank with sensors (top and bottom) Hot water storage tank affected to heating and domestic hot water Boiler anti-freeze activation 0/ B ON or OFF contact: I.SYST can be used as an antifreeze activation inlet on circuit B 0/ C ON or OFF contact: I.SYST can be used as an antifreeze activation inlet on circuit C 0/ DHW ON or OFF contact: I.SYST can be used as an antifreeze activation inlet on circuit ECS 0/ AUX () ON or OFF contact: I.SYST can be used as an antifreeze activation inlet on circuit AUXWhen I.SYST is not active, the auxiliary circuit (AUX) follows the maximum boiler temperature (parameter BOILER MAX). 3WV 3WV SYSTEM CT.TEL () CLOSE See table below. CLOSE OPEN () The parameter is only displayed if INSTALLATION is set to EXTENDED () According to the configuration (3) The parameter is only displayed if CONFIGURATION is set to OTH+3WV (4) The parameter is only displayed if IN 0-0V is set to OFF 39 //

41 isense Pro DIN - AD80 5. Operating the appliance - #SYSTEM menu Parameter Adjustment range Description Factory setting Customer setting I.TEL: ()(4) ANTIFR Boiler anti-freeze activation ANTIFR 0/ B ON or OFF contact: I.TEL: can be used as an antifreeze activation inlet on circuit B 0/ C ON or OFF contact: I.TEL: can be used as an antifreeze activation inlet on circuit C 0/ DHW ON or OFF contact: I.TEL: can be used as an antifreeze activation inlet on circuit ECS 0/ AUX () ON or OFF contact: I.TEL: can be used as an antifreeze activation inlet on circuit AUXWhen I.TEL: is not active, the auxiliary circuit (AUX) follows the maximum boiler temperature (parameter BOILER MAX). IN 0-0V () OFF The 0-0V inlet on the terminal block can be used as a telephone inlet. ON Activating the 0-0 V function () The parameter is only displayed if INSTALLATION is set to EXTENDED () According to the configuration (3) The parameter is only displayed if CONFIGURATION is set to OTH+3WV (4) The parameter is only displayed if IN 0-0V is set to OFF OFF Influence of the parameter setting CT.TEL on the I.TEL: contact CT.TEL I.TEL: I.TEL: contact closed I.TEL: contact open CLOSE ANTIFR The antifreeze mode is active on all boiler circuits. The mode selected on the boiler is active. 0/ B The mode selected on the circuit is active. The antifreeze mode is active on the circuit concerned. 0/ C The mode selected on the circuit is active. The antifreeze mode is active on the circuit concerned. 0/ DHW The mode selected on the DHW circuit is active. The antifreeze mode is active for the DHW circuit. 0/ AUX 4 The MAUX outlet on the connection terminal block is active. 4 The MAUX outlet on the connection terminal block is not active. 4 The boiler operates at a setpoint temperature equal to BOILER MAX. 4 The boiler operates with a setpoint temperature as a function of the outside temperature. OPEN ANTIFR The mode selected on the boiler is active. The antifreeze mode is active on all boiler circuits. 0/ B The antifreeze mode is active on the circuit concerned. 0/ C The antifreeze mode is active on the circuit concerned. The mode selected on the circuit is active. The mode selected on the circuit is active. 0/ DHW The antifreeze mode is active for the DHW circuit. The mode selected on the DHW circuit is active. 0/ AUX 4 The MAUX outlet on the connection terminal block is not active. 4 The boiler operates with a setpoint temperature as a function of the outside temperature. 4 The MAUX outlet on the connection terminal block is active. 4 The boiler operates at a setpoint temperature equal to BOILER MAX. //

42 5. Operating the appliance isense Pro DIN - AD80 Influence of the parameter setting CTC.I.SYST on the I.SYST contact CTC.I.SYST I.SYST I.SYST contact closed I.SYST contact open CLOSE ANTIFR The antifreeze mode is active on all boiler circuits. The mode selected on the boiler is active. 0/ B The mode selected on the circuit is active. The antifreeze mode is active on the circuit concerned. 0/ C The mode selected on the circuit is active. The antifreeze mode is active on the circuit concerned. 0/ DHW The mode selected on the DHW circuit is active. The antifreeze mode is active for the DHW circuit. 0/ AUX 4 The MAUX outlet on the connection terminal block is active. 4 The MAUX outlet on the connection terminal block is not active. 4 The boiler operates at a setpoint temperature 4 equal to BOILER MAX. The boiler operates with a setpoint temperature as a function of the outside temperature. OPEN ANTIFR The mode selected on the boiler is active. The antifreeze mode is active on all boiler circuits. 0/ B The antifreeze mode is active on the circuit concerned. 0/ C The antifreeze mode is active on the circuit concerned. The mode selected on the circuit is active. The mode selected on the circuit is active. 0/ DHW The antifreeze mode is active for the DHW circuit. The mode selected on the DHW circuit is active. 0/ AUX 4 The MAUX outlet on the connection terminal block is not active. 4 The boiler operates with a setpoint temperature as a function of the outside temperature. 4 The MAUX outlet on the connection terminal block is active. 4 The boiler operates at a setpoint temperature equal to BOILER MAX Naming the circuits and generators AUTO TEMP.: 68 5" SUNDAY :45. Access the installer level: Press key - for around 5 seconds.. Select the menu #NAMES OF THE CIRCUITS. 4 Turn the rotary button to scroll through the menus or modify a value. 4 Press the rotary button to access the selected menu or confirm a value modification. ¼For a detailed explanation of menu browsing, refer to the chapter: "Browsing in the menus", page 36 bar AUTO E F G H I. CIRC.B I "Personalize the nameof this circuit B" C0035-F Select the circuit or generator you wish to rename. - #NAMES OF THE CIRCUITS menu Parameter Description Name given by the customer CIRC. B: Circuit B CIRC. C: Circuit C CIRC.AUX Auxiliary circuit CIRC.DHW GENE Generator Domestic hot water circuit 4. Turn the rotary button to choose the first character from the list. To confirm, press the rotary button. 5. Then press again to enter a second character or turn the rotary button to leave an empty space. C00344-E-04 4 //

43 isense Pro DIN - AD80 5. Operating the appliance 6. Choose the other characters in the same way. The input zone may contain up to 6 characters. To move from one character to another, turn the rotary button. To exit without modifications, press key h.. X Y Z 7. To confirm the name, press the rotary button and then turn the button slightly anti-clockwise. When the symbol U appears, press the rotary button. The name is confirmed. If the name reaches 6 characters, it is automatically confirmed when the last character is confirmed. bar CIRC.B FLOOR "Personalize the nameof this circuit B" AUTO C00345-D Setting the heating curve AUTO TEMP.: 68 5" SUNDAY :45 C0035-F-04. Access the installer level: Press key - for around 5 seconds.. Select the menu #SECONDARY INSTAL.P. 4 Turn the rotary button to scroll through the menus or modify a value. 4 Press the rotary button to access the selected menu or confirm a value modification. ¼For a detailed explanation of menu browsing, refer to the chapter: "Browsing in the menus", page Select the parameter CIRC. CURVE... bar BUILD.INERTIA CIRC.CURVE B CIRC.CURVE C SCREED DRYING AUTO No C0036-E-04 //

44 5. Operating the appliance isense Pro DIN - AD80 4. To modify the value directly, turn the rotary button. To modify the value by displaying the curve, press key f. bar CIRC.CURVE B.0 "Slope of the heatcurve of the circuit B" AUTO bar AUTO 0.7 C0037-D-04 0,7 5. To modify the curve, turn the rotary button. 6. To confirm, press the rotary button. To cancel, press key h. 0.7 = Heating curve set. C0038-B-04 Heating curve without BCT 75 C A Z E Maximum temperature of the circuit Water temperature in the circuit for an outside temperature of 0 C DAY set point on the circuit 50 R Outside temperature for which the maximum water temperature in the circuit is reached 5.5 T Value of the heating curve Select the parameter CIRC. CURVE C When you modify the heating curve, Z and R are recalculated and repositioned automatically. C0039-B Heating curve with BCT The BCT (Base heat Curve Temperature) parameter allows a minimum operating temperature to be imposed on the heating circuit (this temperature may be constant if the circuit gradient is nil). 43 //

45 isense Pro DIN - AD80 5. Operating the appliance C X C 4 C0030-B 5.6 Changing the settings A Z E R T x Maximum temperature of the circuit Water temperature in the circuit for an outside temperature of 0 C DAY set point on the circuit Outside temperature for which the maximum water temperature in the circuit is reached Value of the heating curve Select the parameter CIRC. CURVE... Value set to the parameter HCZP D When you modify the heating curve, Z and R are recalculated and repositioned automatically. The module is set for the most common heating systems. With these settings, practically all heating systems operate correctly. The user or installer can optimise the parameters according to own preferences. ¼For the user settings, refer to the user instructions Language selection AUTO TEMP.: 68 5" SUNDAY :45 C0035-F-04. Access the installer level: Press key - for around 5 seconds.. Select the menu #LANGUAGE. 4 Turn the rotary button to scroll through the menus or modify a value. 4 Press the rotary button to access the selected menu or confirm a value modification. ¼For a detailed explanation of menu browsing, refer to the chapter: "Browsing in the menus", page 36 - Menu #LANGUAGE Adjustment range FRANCAIS DEUTSCH ENGLISH ITALIANO ESPANOL NEDERLANDS POLSKI PУCCKИЙ TÜRK Description Display in French Display in German Display in English Display in Italian Display in Spanish Display in Dutch Display in Polish Display in Russian Display in Turkish //

46 5. Operating the appliance isense Pro DIN - AD Defining the configuration mode AUTO TEMP.: 68 5" SUNDAY :45. Access the installer level: Press key - for around 5 seconds.. Select the menu #SYSTEM. 4 Turn the rotary button to scroll through the menus or modify a value. 4 Press the rotary button to access the selected menu or confirm a value modification. ¼For a detailed explanation of menu browsing, refer to the chapter: "Browsing in the menus", page Set the parameter CONFIGURATION to OTH+3WV: C0035-F-04 - #SYSTEM menu Parameter Adjustment range Description Customer setting CONFIGURATION VM/MR Operation with all Diematic control systems - No DHW priority. Do not select this setting 3WV+ 0/+V3V OTH+3WV Operation with Diematic-m 3 - isense Pro control systems - DHW priority available. Do not select this setting Control for an ON/OFF generator Do not select this setting Control for a generator by BUS OpenTherm OTH+3WV Calibrating the sensors bar AUTO SUNDAY :45 C009-D-04. To access user level: Press the > key.. Select the menu #SETTING. 4 Turn the rotary button to scroll through the menus or modify a value. 4 Press the rotary button to access the selected menu or confirm a value modification. ¼For a detailed explanation of menu browsing, refer to the chapter: "Browsing in the menus", page Set the following parameters: 45 //

47 isense Pro DIN - AD80 5. Operating the appliance User level - #SETTING menu Parameter Adjustment range Description Factory setting Customer setting SUM/WIN 5 to 30 C Used to set the outside temperature above which heating will be shut down. NO 4 The heating pumps are shut down. 4 Domestic hot water continues to be produced. 4 The symbol p appears. Heating is never shut down automatically CALIBR. OUT Outside sensor calibration: Used to correct the outside temperature CALIBR. ROOM B () ()(3) OFFSET ROOM B () (4)(3) ANTIFR. ROOM B () ()(3) CALIBR. ROOM C () ()(3) OFFSET ROOM C () (4)(3) ANTIFR. ROOM C () ()(3) Calibration of the room sensor on circuit B Make this setting hours after switching on, when the room temperature has stabilised -5.0 to +5.0 C Room offset on circuit B: Is used to set a room offset Make this setting hours after switching on, when the room temperature has stabilised 0.5 to 0 C Room temperature at which the antifreeze mode is activated on circuit B Calibration of the room sensor on circuit C Make this setting hours after switching on, when the room temperature has stabilised -5.0 to +5.0 C Room offset on circuit C: Is used to set a room offset Make this setting hours after switching on, when the room temperature has stabilised 0.5 to 0 C Room temperature antifreeze activation on circuit C C Outside temperature Room temperature of circuit B C Room temperature of circuit C () The parameter is only displayed if INSTALLATION parameter is set to EXTENDED () The parameter is only displayed if a room sensor is connected to the circuit concerned (3) The parameter is only displayed if the circuit concerned is actually connected (4) The parameter is only displayed if no room sensor is connected to the circuit concerned or the sensor has no influence C Professional settings AUTO TEMP.: 68 5" SUNDAY :45. Access the installer level: Press key - for around 5 seconds.. Set the following parameters: 4 Turn the rotary button to scroll through the menus or modify a value. 4 Press the rotary button to access the selected menu or confirm a value modification. ¼For a detailed explanation of menu browsing, refer to the chapter: "Browsing in the menus", page 36. C0035-F-04 //

48 5. Operating the appliance isense Pro DIN - AD80 - #PRIMARY LIMITS menu () Parameter Adjustment range Description Factory setting Customer setting BOILER MAX () 40 to 90 C Maximum temperature authorised by the boiler 90 C BOILER MIN () 0 to 50 C Minimum temperature authorised by the boiler 0 C () According to the configuration - #SECONDARY LIMITS menu Parameter Adjustment range Description Factory setting MAX.CIRC.B 0 to 95 C Maximum temperature (Circuit B) ¼ "MAX.CIRC...", page 50 MAX.CIRC.C 0 to 95 C Maximum temperature (Circuit C) ¼ "MAX.CIRC...", page 50 OUT.ANTIFREEZE OFF, -8 to +0 C Outside temperature at which the installation s antifreeze protection is activated. Below this temperature the pumps are permanently on and the minimum temperatures for each circuit are respected. When NIGHT : STOP is set, the reduced temperature is maintained in each circuit (#SECONDARY INSTAL.P menu). OFF: Antifreeze protection is not activated HCZP D B ()() OFF, 0 to 90 C Curve base temperature in Daytime mode (Circuit B) OFF HCZP N B ()() OFF, 0 to 90 C Curve base temperature in Nighttime mode (Circuit B) OFF HCZP D C ()() OFF, 0 to 90 C Curve base temperature in Daytime mode (Circuit C) OFF HCZP N C ()() OFF, 0 to 90 C Curve base temperature in Nighttime mode (Circuit C) OFF PRIM.TEMP.DHW () 50 to 95 C Set point temperature if domestic hot water production 80 C () The parameter is only displayed if INSTALLATION parameter is set to EXTENDED () The parameter can be set to the heating curve by pressing key f. 50 C 50 C +3 C - #SECONDARY INSTAL.P menu Parameter Adjustment range Description Factory setting BUILD. INERTIA () 0 (0 hours) to 0 (50 hours) Characterisation of building s inertia: 0 for a building with low thermal inertia. 3 for a building with normal thermal inertia. 0 for a building with high thermal inertia. Modification of the factory setting is only useful in exceptional cases. CIRC.CURVE B () 0 to 4 Heating curve of the circuit B ¼ "CIRC. CURVE...", page 50 ANTICIP.B 0.0 to 0.0 Activation and adjustment of the anticipation time ¼ "ANTICIP.B, ANTICIP.C ", page 50 ROOM INFL. B () 0 to 0 Influence of room sensor B ¼ "ROOM S.INFL", page 5 () The parameter is only displayed if INSTALLATION parameter is set to EXTENDED () The parameter can be set to the heating curve by pressing key f (3) The parameter is only displayed if SCREED DRYING is other than OFF (4) According to the configuration (5) The parameter is only displayed if IN 0-0V is set to ON. (6) If a reversal valve is connected, DHW priority will always be total regardless of the setting. 3 ( hours) 0.7 NO 3 Customer setting 47 //

After Sales Service Guide

After Sales Service Guide After Sales Service Guide Control panel DIEMATIC isystem For INNOVENS MCA wall-hung gas condensing boilers 300022803-00-B /02/200 Use of this guide is reserved for qualified professionals Any intervention

More information

Innovens Pro. Wall-hung gas condensing boilers MCA Installation and Service Manual A

Innovens Pro. Wall-hung gas condensing boilers MCA Installation and Service Manual A Innovens Pro EN Wall-hung gas condensing boilers MCA 45-65 - 90-5 Installation and Service Manual 3000487-00-A EG declaration of conformity The device complies with the standard type described in the EG

More information

C 230 ECO. Control panel. DIEMATIC-m3 (GV6) Installation and Service Manual E

C 230 ECO. Control panel. DIEMATIC-m3 (GV6) Installation and Service Manual E C 230 ECO Control panel DIEMATIC-m3 (GV6) EN Installation and Service Manual 300015243-001-E Contents 1 Introduction.............................................................................3 1.1 Used

More information

DIEMATIC VM isystem WALL-MOUNTED CONTROL SYSTEM. DIMENSIONS Length: 320 mm Height: 260 mm Depth: 130 mm. POWER SUPPLY 230 V, 50 Hz, 6 A

DIEMATIC VM isystem WALL-MOUNTED CONTROL SYSTEM. DIMENSIONS Length: 320 mm Height: 260 mm Depth: 130 mm. POWER SUPPLY 230 V, 50 Hz, 6 A DIEMATIC WALL-MOUNTED CONTROL SYSTEM Electronic control system capable of controlling 2 heating circuits, a DHW circuit and an auxiliary circuit EC identification No.: 0085CM0178 Electronic microprocessor

More information

MCA 15 - MCA 25 MCA 25/28 MI

MCA 15 - MCA 25 MCA 25/28 MI Innovens EN Wall-hung gas condensing boilers MCA 5 - MCA 5 MCA 5/8 MI User Guide 30006-00-0 Contents Introduction...4. Symbols used...4. Abbreviations...4.3 General...5.3. Manufacturer's liability...5.3.

More information

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO Great Britain en Installation, user and service manual Control panel HMI Gas 310/610 ECO PRO Dear Customer, Thank you very much for buying this appliance. Please read through the manual carefully before

More information

INSTRUCTION FOR THE USER THC V E OIL BLU

INSTRUCTION FOR THE USER THC V E OIL BLU INSTRUCTION FOR THE THC V E OIL BLU CONTENTS General safety information 4 Precautions 4 Control panel 5 Mode selection 8 User levels 10 Start-up 12 Temporary shutdown 15 Preparing for extended periods

More information

ADVANCE EASYLIFE PROJECT

ADVANCE EASYLIFE PROJECT ADVANCE EASYLIFE PROJECT DIEMATIC 3 and -m 3 control panels... p. 232 DIEMATIC isystem control panel... p. 234 DIEMATIC 3 DIEMATIC VM isystem wall-hung control unit... p. 235 Room thermostats and miscellaneous...

More information

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

1 DOCUMENT REVISION CONTROL ELEMENTS... 9 CONTENTS Contents 1 DOCUMENT REVISION... 8 2 SOFTWARE VERSION... 8 3 BASIC DESCRIPTION... 8 4 CONTROL ELEMENTS... 9 4.1 BASIC DISPLAYS...10 4.2 CONTROL KEYS...11 4.2.1 Rotary button (Press / Turn)...11

More information

Modulating clock thermostat

Modulating clock thermostat EN Digital timer thermosatat Modulating clock thermostat Installation and Service Manual 123189-AB Contents 1 Preface...4 1.1 General...4 2 Location of the installation...5 2.1 Position of the regulator...5

More information

MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI

MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI Vivadens EN Wall-hung gas condensing boilers MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI User Guide 300015874-001-B Contents 1 Introduction...4 1.1 Used symbols...4 1.2 Abbreviations...4 1.3 General...4

More information

Operation manual FR EN NL DE IT. intended for professionals and end users. To be saved for future consultation

Operation manual FR EN NL DE IT. intended for professionals and end users. To be saved for future consultation Document n 1408-1 ~ 11/02/2010 Control Box FR EN NL DE IT Operation manual intended for professionals and end users To be saved for future consultation Fujitsu General (Euro) GmbH Werftstrasse 20 40549

More information

Oil-fired condensing boiler GTU C 330. User Guide B

Oil-fired condensing boiler GTU C 330. User Guide B EN Oil-fired condensing boiler GTU C 330 User Guide 300017846-001-B . Contents 1 Introduction.............................................................................3 1.1 Symbols and abbreviations................................................................................3

More information

BM Programming Module. For the heating engineer Installation instructions

BM Programming Module. For the heating engineer Installation instructions For the heating engineer Installation instructions BM Programming Module WOLF GmbH Postfach 1380 84048 Mainburg Tel. 08751/74-0 www.wolf-heiztechnik.de Document no.: 3062612_201509 Subject to modifications

More information

MIT-II/E - MIT-II/H MIT/EP - MIT/HP QUADROPAC DUP 500

MIT-II/E - MIT-II/H MIT/EP - MIT/HP QUADROPAC DUP 500 EN Control panel MIT-II/E - MIT-II/H MIT/EP - MIT/HP QUADROPAC DUP 500 User Guide 300015090-001-L Contents 1 Used symbols...........................................................................3 2 Important

More information

Installation and servicing instructions

Installation and servicing instructions Installation and servicing instructions Programming unit RC35 For qualified professionals Please read carefully prior to commissioning and servicing 7 747 006 341-12/2006 GB Contents Contents Contents

More information

Climapro 2. User manual. wireless room thermostat without receiver. To be left with the user.

Climapro 2. User manual. wireless room thermostat without receiver. To be left with the user. Climapro 2 User manual To be left with the user wireless room thermostat without receiver www.glow-worm.co.uk table of contents READ CAREFULLY BEFORE USING 1 Introducing your Climapro 2... 3 1.1 Description...

More information

BSC...E - BSP...E - BESC...E

BSC...E - BSP...E - BESC...E INISOL DUO E DIETRISOL DUO E Solar hot water calorifer BSC...E - BSP...E - BESC...E EN User Guide 0007781-001-01 Contents 1 Introduction.............................................................................

More information

Operating instructions

Operating instructions Operating instructions Room controller 6 720 618 477-00.1RS Logamatic EMS RC35 programming unit For users Read carefully before use. 6 720 642 272 (10/2009) GB Overview of controls Overview of controls

More information

Condensing Boiler RS100 Controller Training Program

Condensing Boiler RS100 Controller Training Program Condensing Boiler RS100 Controller Training Program Training Program #501102A 062311 www.rinnai.us 2009 Rinnai America Corporation Features and Benefits The RS100 connects directly to the boiler and acts

More information

Vivadens. Wall-hung gas condensing boilers MCR 24/28 BIC. User Guide B

Vivadens. Wall-hung gas condensing boilers MCR 24/28 BIC. User Guide B Vivadens EN Wall-hung gas condensing boilers MCR 24/28 BIC User Guide 300024112-001-B Contents 1 Introduction...4 1.1 Symbols used...4 1.2 Abbreviations...4 1.3 General...4 1.3.1 Manufacturer's liability...4

More information

Gas-fired boilers DTG 230. User Guide D

Gas-fired boilers DTG 230. User Guide D EN Gas-fired boilers DTG 230 User Guide 300011506-001-D . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3

More information

R. Room temperature controller with solar control FR 120. Operating instructions for the user (2012/02)

R. Room temperature controller with solar control FR 120. Operating instructions for the user (2012/02) 6 720 612 481-00.1R Room temperature controller with solar control FR 120 Operating instructions for the user 2 Dear Customer, The controller is the cool head of your heating system. At the factory, we

More information

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O HMC300 Control unit EMS plus 6 720 808 471-00.1O Operating Instructions 6 720 813 192 (2014/10) Contents Contents Key to symbols and safety instructions................3 1.1 Key to symbols...........................

More information

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS... User Manual Contents 1 DOCUMENT REVISION... 4 2 SOFTWARE VERSION... 4 3 BASIC DESCRIPTION... 4 4 BASIC OVERVIEW OF HYDRAULIC DIAGRAMS... 5 4.1 BOILER NOT CONTROLLED BY THE CONTROLLER:... 5 4.2 BOILER CONTROLLED

More information

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat. ROOM THERMOSTAT SYSTEM Radio frequency controlled programmable room thermostat. LARGE RECEIVER: 24CDi, 26CDi Xtra, 28CDi, 35CDi Mk I and 35CDi Mk II SMALL RECEIVER: 24i Junior, 28i Junior and Si Mk II

More information

MCA 15 - MCA 25 MCA 25/28 MI

MCA 15 - MCA 25 MCA 25/28 MI Innovens EN Wall-hung gas condensing boilers MCA 5 - MCA 5 MCA 5/8 MI Installation and Service Manual 300046-00-B MCA 5 - MCA 5 MCA 5/8 MI Declaration of conformity The appliance complies with the standard

More information

Boiler controller Lambdatronic S 3200

Boiler controller Lambdatronic S 3200 Operating Instructions Boiler controller Lambdatronic S 3200 Version 50.04 - Build 05.04 Translation of the original German operating instructions for technicians and operators Read and follow the instructions

More information

WHE 2.24 / WHE 2.24 FF

WHE 2.24 / WHE 2.24 FF EN Wall-hung gas boilers WHE 2.24 WHE 2.24 FF User Guide 300011777-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3

More information

prestige Control Application Supplement - TriMax

prestige Control Application Supplement - TriMax prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY

RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY USER GUIDE RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification

More information

DTG Eco / V130

DTG Eco / V130 ECODENS Gas fired condensing boiler EN User Guide 300010111-001-B Contents 1 Introduction.............................................................................3 1.1 Symbols and abbreviations................................................................................3

More information

COnDEnSInG BOIlERS TAU UNIT OIL USER parameters manual

COnDEnSInG BOIlERS TAU UNIT OIL USER parameters manual CONDENSING BOILERS TAU UNIT OIL USER parameters manual 1 CONTENTS List of end user level parameters 3 Setting functioning parameters 6 -- Time programs 6 -- Heating circuits 6 -- Room temperature 7 --

More information

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM OD (FOR EXTERNAL USE)

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM OD (FOR EXTERNAL USE) INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM OD (FOR EXTERNAL USE) Thank you for choosing a DOMUSA TEKNIK heating boiler. Within the product range offered by DOMUSA TEKNIK you have chosen BioClass

More information

Heating Controller SDC Remote Heating Controller DHC

Heating Controller SDC Remote Heating Controller DHC Heating Controller SDC Remote Heating Controller DHC PARAMETER LIST EN0B-0565GE51 R0313 EN0B-0565GE51 R0313 Contents Contents 1 Software version...5 2 Access to the technician / OEM area...5 3 "Hydraulics"

More information

Boiler controller S-Tronic Plus

Boiler controller S-Tronic Plus Operating Instructions Boiler controller S-Tronic Plus Version 50.0 - Build 05.0 Translation of the original German operating instructions for technicians and operators Read and follow the instructions

More information

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM Radio frequency controlled programmable room thermostat FOR GREENSTAR 25 HE and GREENSTAR 30 HE MODELS Hol Man Auto Day SIGNAL HEATING ON OVERRIDE

More information

SOLNEO SGC 24 SOL. User Guide. Gas fired condensing boiler C

SOLNEO SGC 24 SOL. User Guide. Gas fired condensing boiler C SOLNEO EN Gas fired condensing boiler SGC 24 SOL User Guide 300017555-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols and abbreviations................................................................................3

More information

Heating Controller SDC. District Heating Controller DHC 43 OPERATING INSTRUCTIONS

Heating Controller SDC. District Heating Controller DHC 43 OPERATING INSTRUCTIONS Heating Controller SDC District Heating Controller DHC 43 OPERATING INSTRUCTIONS Copyright 2002 Honeywell Inc. EN2H-0220 GE51 R0802 SDC / DHC 43 Operating Instructions EN2H-0220 GE51 R0802 Contents SDC

More information

PROGRAMMABLE 7-DAY RF THERMOSTAT

PROGRAMMABLE 7-DAY RF THERMOSTAT PROGRAMMABLE 7-DAY RF THERMOSTAT Installation and user instruction This instructions to be retained by the user 1 Thank you for choosing Beretta s radio frequency (RF) Radiostat. This central heating control

More information

CM901 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

CM901 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET CM90 PROGRAMMABLE THERMOSTAT PRODUCT SPECIFICATION SHEET FEATURES Attractive, slim, ultra-modern styling makes it ideal for location in any type of home. 24 hour heating program. A dynamic text display

More information

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data. ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data. The RVA63 controller can be utilized to control the following system configurations via LPB communication. Equipment Required

More information

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM Thank you for choosing a DOMUSA TEKNIK heating boiler. Within the product range offered by DOMUSA TEKNIK you have chosen BioClass HM model. With a suitable

More information

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET DT92 WIRELESS DIGITAL ROOM THERMOSTAT PRODUCT SPECIFICATION SHEET The new DT92 family of wireless digital room thermostats is a range of market leading products designed to provide comfort with economy

More information

- Data Brochure Steam Control 279

- Data Brochure Steam Control 279 - Data Brochure Steam Control 279 D 279 12/07 The tekmar Steam Control 279 can operate a single on-off steam boiler or an on-off steam valve using outdoor reset. The control determines the on time of the

More information

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb. Edition 06.14 GB Operating and installation instructions Lago FB digital remote control Translation from the German 2014 Elster GmbH Safety Please read and keep in a safe place Please read through these

More information

System Installation. multi-zone heating

System Installation. multi-zone heating System Installation multi-zone heating Table of contents INTRODUCTION 1 Instructions guidance... 2 1.1 Product documentation...2 1.2 Associated documents...2 1.3 Explanation of symbols...2 1.4 Guarantee

More information

Service Manual Models:

Service Manual Models: KBXII-SER Rev A Models: 400-801 WARNING This manual must only be used by a qualified heating installer / service technician. Read all instructions, including this manual and the Knight XL Installation

More information

Control Application. Supplement - ACVMax

Control Application. Supplement - ACVMax prestige Control Application Supplement - ACVMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

multimatic Operating instructions AT, BE (de), CH (de), DE VRC 700f/4

multimatic Operating instructions AT, BE (de), CH (de), DE VRC 700f/4 Operating instructions multimatic VRC 700f/4 AT, BE (de), CH (de), DE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Tel. +49 21 91 18 0 Fax +49 21 91 18 2810 info@vaillant.de

More information

Service Manual Models:

Service Manual Models: KBXII-SER_100161490_2000013413_Rev L Service Manual Models: 400-801 WARNING This manual must only be used by a qualified heating installer / service technician. Read all instructions, including this manual

More information

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating 2 477 Heating Controller for 2 heating circuits, dhw and boiler, communicating RVP330 Multi-functional heating controller for use in residential and non-residential buildings Suitable for weather-compensated

More information

ENGLISH. REMOTE CONTROL / ROOM THERMOSTAT Wireless INSTALLATION SERVICING AND USER MANUAL

ENGLISH. REMOTE CONTROL / ROOM THERMOSTAT Wireless INSTALLATION SERVICING AND USER MANUAL ENGLISH REMOTE CONTROL / ROOM THERMOSTAT Wireless INSTALLATION SERVICING AND USER MANUAL DANGER! Serious danger to safety and health ATTENTION! Possible dangerous situation for the product and the environment

More information

prestige Control Application Supplement - TriMax

prestige Control Application Supplement - TriMax prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

multimatic Operating instructions Operating instructions For the operator AT, BE (de), CH (de), DE VRC 700f/4 Publisher/manufacturer Vaillant GmbH

multimatic Operating instructions Operating instructions For the operator AT, BE (de), CH (de), DE VRC 700f/4 Publisher/manufacturer Vaillant GmbH Operating instructions For the operator Operating instructions multimatic VRC 700f/4 AT, BE (de), CH (de), DE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Tel. +49 21 91 18

More information

Heating Controller SDC Remote Heating Controller DHC

Heating Controller SDC Remote Heating Controller DHC Heating Controller SDC Remote Heating Controller DHC PARAMETER LIST EN0B-0565GE51 R0308 EN0B-0565GE51 R0308 Contents Contents 1 Software version... 5 2 Access to the technician / OEM area... 5 3 "Hydraulics"

More information

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

EBC20. Instructions for fitting, installation and operation. Read and save these instructions! EBC20 UK Instructions for fitting, installation and operation Read and save these instructions! 2 3002878 EBC20 UK 290415 1. Product information............................................... 4 1.1 Delivery.............................................................

More information

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating 2 526 Heating Controller including dhw heating Series C RVL472 Multifunctional heating controller for use in residential and non-residential buildings Suited for: Heating zone control with or without room

More information

prestige Control Application Supplement - ACVMax

prestige Control Application Supplement - ACVMax 2015-10 Prestige ACVMax Control Sup 12-14-15_ACVMax_Control 12/15/15 7:36 AM Page 1 prestige Control Application Supplement - ACVMax L I S T E D WARNING This document is intended to be used by a factory

More information

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND Aqua Balance AquaBalance TM CONTROL MODULE QUICK START GUIDE 10 1 Domestic Hot Water temperature setpoint decreasing button 2 Domestic Hot Water temperature setpoint increasing button 3 Central Heating

More information

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products 2 478 Heating Controller for 2 heating circuits, d.h.w. and boiler RVP331 Multi-functional heating controller for use in residential and non-residential buildings Suitable for weather-compensated flow

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

Operating Instructions for use by heating contractor. VITOTRONIC r 100 VITOTRONIC r 300-K IMPORTANT

Operating Instructions for use by heating contractor. VITOTRONIC r 100 VITOTRONIC r 300-K IMPORTANT Operating Instructions for use by heating contractor Vitotronic 100, type GC1B Multi boiler system with control unit for constant temperature operation For use with Boiler models VD2A, VD2 and CT3 Vitotronic

More information

USERS MANUAL FOR GAS BOILERS

USERS MANUAL FOR GAS BOILERS USERS MANUAL FOR GAS BOILERS PLEASE READ THE MANUAL CAREFULLY: IT CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, INSTALLATION, USE AND MAINTENANCE OF THE APPLIANCE MODELS: NOVADENS 24 NOVADENS 24C NOVADENS

More information

PROGRAMMABLE 7-DAY THERMOSTAT

PROGRAMMABLE 7-DAY THERMOSTAT PROGRAMMABLE 7-DAY THERMOSTAT Installation and user instruction This instructions to be retained by the user 1 Thank you for choosing Riello s weekly programmer.. This central heating control device is

More information

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A... 70 80 99-00-O Residential Gas Condensing Boiler ZBR//8/35/4-3A... ZWB8/35/4-3A... 70 80 993 (03/03) CA/US Operating Instructions Contents Contents Key to symbols and safety instructions............................

More information

Innovens. Wall-hung gas condensing boilers MCA 25/28 BIC. Installation and Service Manual

Innovens. Wall-hung gas condensing boilers MCA 25/28 BIC. Installation and Service Manual Innovens EN Wall-hung gas condensing boilers MCA 5/8 BIC Installation and Service Manual 300059-00-0 EG declaration of conformity The device complies with the standard type described in the EG declaration

More information

G a

G a G2474 74 319 0081 0 a en Installation Instructions Heating controllers RVP3... Installation Place of installation In a dry room, e.g. in the boiler room Mounting choices: Control cabinet (in the front,

More information

E-COMBI EVO E-SYSTEM EVO

E-COMBI EVO E-SYSTEM EVO E-COMBI EVO E-SYSTEM EVO User s manual CONDENSING WALL-HUNG GAS BOILER G.C.N.:47-116-68 (24 kw) G.C.N.:47-116-69 (30 kw) G.C.N.:47-116-70 (38 kw) G.C.N.:41-116-39 (24 kw) G.C.N.:41-116-40 (30 kw) Country

More information

KIT UNITÀ AMBIENTE E INTERFACCIA A LED KIT ROOM UNIT AND LED INTERFACE RAUMGERÄT UND LED-SCHNITTSTELLE KIT APPAREIL D'AMBIANCE ET INTERFACE À LEDS

KIT UNITÀ AMBIENTE E INTERFACCIA A LED KIT ROOM UNIT AND LED INTERFACE RAUMGERÄT UND LED-SCHNITTSTELLE KIT APPAREIL D'AMBIANCE ET INTERFACE À LEDS A it KIT UNITÀ AMBIENTE E INTERFACCIA A LED PER IL CONTROLLO DELLA TEMPERATURA AMBIENTE DEL LOCALE en KIT ROOM UNIT AND LED INTERFACE ROOM TEMPERATURE CONTROL ACCESSORY de RAUMGERÄT UND LED-SCHNITTSTELLE

More information

CM907- TRV PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

CM907- TRV PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET CM907- TRV PROGRAMMABLE THERMOSTAT PRODUCT SPECIFICATION SHEET FEATURES Attractive, slim, ultra-modern styling makes it ideal for location in any type of home. 7-day heating program. A dynamic text display

More information

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel: 0020051423-02 10.07 British Gas 330+ High Efficiency Condensing Boiler Instructions for Use To b e l e f t w i t h t h e u s e r British Gas Service Tel: 0845 9500400 WARNING GAS LEAK OR FAULT Turn off

More information

ProCon Boiler Controller Commissioning Quick Reference Guide

ProCon Boiler Controller Commissioning Quick Reference Guide ProCon Boiler Controller Commissioning Quick Reference Guide This sheet is intended as a quick reference guide and should be read in conjunction with the operating and maintenance manual for the boiler

More information

DT90 DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

DT90 DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET DT90 DIGITAL ROOM THERMOSTAT PRODUCT SPECIFICATION SHEET The new DT90 family of digital room thermostats is a range of market leading products designed to provide comfort with economy in modern heating

More information

ST 53.1 User s manual

ST 53.1 User s manual Tech - 1 - ST 53.1 User s manual Table of contents I. Safety... 3 II. Description... 4 III. Installation... 4 IV. Operating the Controller... 6 IV.a) Principle of Operation... 6 IV.b) Control... 6 V. Controller

More information

2-zone application 2X T6R SMART THERMOSTAT & 2-CHANNEL RECEIVER BOX FEATURES APPLICATION MANUAL

2-zone application 2X T6R SMART THERMOSTAT & 2-CHANNEL RECEIVER BOX FEATURES APPLICATION MANUAL 2-zone application 2X T6R SMART THERMOSTAT & 2-CHANNEL RECEIVER BOX APPLICATION MANUAL FEATURES With the new 2-channel Receiver box (R6H911RF) and 2x a T6R wireless smart thermostats (T6H700RW) automatic

More information

IDEAL E-NERGY Thermostat Touch type User Manual

IDEAL E-NERGY Thermostat Touch type User Manual 67800 03/18 (JRK) IDEAL E-NERGY Thermostat Touch type 203250 User Manual WWW.MFH-SYSTEMS.COM Contents Menu Overview............... 3 Introduction................. 4 Startup Wizard 1/2.............. 5 Startup

More information

Control System THETA. Operating Instructions. Room control unit RSC and RSC-OT

Control System THETA. Operating Instructions. Room control unit RSC and RSC-OT Control System THETA Operating Instructions Room control unit RSC and RSC-OT Table of contents Page 2 USER LEVEL Operating instruments........................................................................................4

More information

RVP310. Heating Controller. Building Technologies HVAC Products

RVP310. Heating Controller. Building Technologies HVAC Products 2 475 Heating Controller RVP310 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones with or

More information

CONTROL CABINET for cascade boiler systems

CONTROL CABINET for cascade boiler systems IST 03 C 000-00 CONTROL CABINET for cascade boiler systems EN INSTALLATION USE AND MAINTENANCE Dear Customer, Thank you for choosing and buying a piece of our equipment. Please read these instructions

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

Installation Guide. ECL Comfort 210, application A Table of Contents

Installation Guide. ECL Comfort 210, application A Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1 1.1 Important safety and product information..................... 2 2.0 Installation... 4 2.1 Before you start.....................................................

More information

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY RC 06 0712_1403 it - Istruzioni TELECONTROLLO en - Remote controller instruction hu - Utasítás TÁVVEZÉRLÉS ru - Руководство по эксплуатации pl - Instrukcja obsługi { 1. Commissioning of the boiler 26 2.

More information

Operating instructions

Operating instructions Operating instructions Control unit - CGL Zone 0.0 C Friday 3/0/08 : 6 Wolf GmbH Postfach 380 D-84048 Mainburg Tel. +49 (0)875/74-0 Fax +49 (0)875/74600 Internet: www.wolf-heiztechnik.de Document no.:

More information

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502*

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502* User's Guide VI.7B.D5.02 2005.10 P20 *VI7BD502* *087R8014* www.danfoss.com ECL Comfort User's Guide ECL Comfort Installer's Guide www.danfoss.com *087R8014* *VI7BD502* Boiler controller P20 VI.7B.D5.02

More information

Chiller Organizer 2/3

Chiller Organizer 2/3 Chiller Organizer 2/3 OPERATOR S MANUAL Introduction The Chiller Organizer 2/3, is a further evolution of the basic model Chiller Organizer, and it is a microprocessor-based device, which translates with

More information

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller Mounting and Operating Instructions Electronics from SAMSON EB 5610 EN Firmware version 1.40 Edition December 2014 Controller

More information

Operating instructions

Operating instructions Operating instructions Control unit Logamatic 4211 For users Read carefully before use 7 747 016 927-03/2008 GB/IE Contents 1 Introduction................................................ 4 2 What you should

More information

Quickheat 30 weather compensated boiler control

Quickheat 30 weather compensated boiler control Quickheat 0 weather compensated boiler control A compact and sophisticated heating controller The compact KM controller is designed for the control of fan assisted boilers with modulating burners. The

More information

Service Manual Models: Series 100 & 101

Service Manual Models: Series 100 & 101 100305279_2000558130 Rev A Service Manual Models: 55-285 Series 100 & 101 WARNING This manual must only be used by a qualified heating installer / service technician. Read all instructions, including this

More information

Diplomat Inverter/Diplomat Duo Inverter

Diplomat Inverter/Diplomat Duo Inverter www.thermia.com The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive 2006/42/EC) Copyright Thermia Värmepumpar Table of

More information

User Instructions For TopTronic RS-30

User Instructions For TopTronic RS-30 User Instructions F TopTronic RS-30 430294ENG-Jun02 Hoval Ltd Nthgate Newark Nottinghamshire NG24 1JN Phone 01636 672711 Fax 01636 673532 2 Index 430294ENG-Jun02 Introduction Introduction... 3 Controls...

More information

Installation & User s Instructions

Installation & User s Instructions Installation & User s Instructions 8 080 shown Part No. 00 day Wired Digital Programmer & Room Sensor Part No. 080 day Wireless Digital Programmer & Room Sensor Part No. 00 hr Wireless Digital Programmer

More information

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER Heating Circuit ZONE Controller RVA 46.531/109 Zonal temperature controller for control of a lowtemperature heating system, for use with condensing gas boilers Instructions for the INSTALLER INDEX Page

More information

Poolsmart Plus Touchscreen Heating Controller. Installation & Operating Manual

Poolsmart Plus Touchscreen Heating Controller. Installation & Operating Manual Poolsmart Plus Touchscreen Heating Controller Installation & Operating Manual Important Notes Congratulations on purchasing the PoolSmart Plus touchscreen heating controller, manufactured in England to

More information

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning G2524en Heating controller Installation Instructions RVL471 1 Installation 1.1 Place of installation In a dry room, e.g. the boiler room Mounting choices: In a control panel (on the inner wall or on a

More information

Installation and Operating Manual. Merlin 5064 V3. System Manager

Installation and Operating Manual. Merlin 5064 V3. System Manager Installation and Operating Manual Merlin 5064 V3 System Manager Please observe the safety instructions and read through this manual carefully before commissioning the equipment. Safety information General

More information

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button USER MANUAL Type UCG/UDG 57116D 06/12 (MBC) 1.10 2012 OJ Electronics A/S...1 Français...7 Español... 14 Type UCG/UDG Contents Introduction...1 First Time Settings...1 Ground Fault Circuit Interrupter (GFCI)...1

More information

RVL481. Heating Controller. including d.h.w. heating

RVL481. Heating Controller. including d.h.w. heating 2 541 Heating Controller including d.h.w. heating RVL481 Multifunctional and communicating heating controller for use in residential and non-residential buildings. Suited for heating circuit control with

More information

Operating instructions THETA control unit for heating contractors. ROTEX control unit: - THETA 23R - THETA RS - THETA HEM1

Operating instructions THETA control unit for heating contractors. ROTEX control unit: - THETA 23R - THETA RS - THETA HEM1 Operating instructions THETA control unit for heating contractors. ROTEX control unit: - THETA 23R - THETA RS - THETA HEM1 Introduction Introduction The ROTEX THETA control unit is a simple to operate

More information