Pro heat station brine

Size: px
Start display at page:

Download "Pro heat station brine"

Transcription

1 Pro heat station brine

2 PWZS / overview 3~400V type overview 3~400V heating capacity at kw at B0/W35 COP at B0/W35 PWZS 42H3S 4,7 4,7 PWZS 62H3S 6,0 4,8 PWZS 82H3S 7,7 4,9 PWZS 102H3S 9,5 5,0 PWZS 122H3S 12,0 4,9

3 PWZS / nomenclature nomenclature (e.g.: PWZS 122H3S) P Pro W heat Z station S brine xx2 heating capacity at B0/W35 (e.g.:122 = 12kW at B0/W35) H heating 3 supply voltage 3~400V S stainless steel tank

4 PWZS / Benchmark Benchmark 2014 PWZS F1245 Kompaktbaureihe Vitocal 343-G geotherm plus manufacturer Alpha InnoTec Nibe Stiebel Eltron Viessmann Vaillant Dimplex Type PWZS 102 H3S F WPC 10 BWT-NC 341.A10 VWS 102/3 SIW 11TU Heating capacity (B0/W35) in kw 1compressor operation COP 9,5 5 9,64 4,81 10,31 5,02 10,3 4,7 10,9 4,9 10,9 5 Heating capacity (B0/W35) in kw 2 compressor COP operation Operating limits heat source C Operating limits heating circuit C Sound power level at B0/W35 according to EN Sound pressure level in 1m distance (in free field) in db(a) Weight in kg Dimension s WxHxD in mm 598 x 1850 x x 1800 x x 1925 x x 2075 x x 1800 x x 2000 x 730 Starting current in A directly with soft starter Safety device heating Brine yes yes - - Expansion vessel heating Brine yes - - Circulation pumps heating brine yes yes yes yes yes yes yes yes yes yes yes yes Overflow valve yes yes Heat quantity recording Electric meter yes - yes - yes yes - - yes - yes - Switching valve or pump for domestic hot water yes yes yes yes yes yes Domestic hot water tank Solar heat yes yes yes - yes - yes - yes yes exchanger - Immersion heater in kw 0, yes yes 6 6 Inverter compressor controller yes yes yes yes yes yes Divisible device yes yes yes yes yes yes

5 PWZS / 3~400V PWZS 42H3S technical data 3~400V PWZS 42H3S limits of use heating circuit return max I heating circuit flow max. C 20 I 60 heat source C additional operating points B0W65 sound Sound pressure level at 1m distance from the edge of the unit db(a) 31 Sound power level according to EN12102 db 43 heat source volume flow: minimum throughout ı nominal throughout analogueue B0W35 ı maximum throughout l/h 700 ı 1050 ı 1575 free external pressure heat pump p (with cooling pk) with Monoethylenglykol (25%) ı volume flow bar (bar) ı l/h 0,6 ( ) ı 1050 approved anti-freeze Monoethylenglykol I Propylenglykol I Methanol I Ethanol frostproof up to C -13 maximum operating pressure bar 3 I I I heating circuit volume flow: minimum throughout ı nominal throughout analogueue B0W35 ı maximum throughout l/h 450 ı 850 ı 1300 free external pressure heat pump p (with cooling pk) ı volume flow bar (bar) ı l/h (0,7) ı 850 maximum operating pressure bar 3 general unit data total weight(with cooling) kg (kg) 215 ( ) weight Box kg 90 weight Tower kg 125 Refrigerant type ı refrigerant capacity ı kg R410A ı 1,20 domestic hot water tank net volume l 186 impressed current anode integrated domestic hot water temperature in pure heat pump operation bis C 59 domestic hot water temperature with electric heating element bis C 65 delivery rate according to EN (40 C with withdrawal of 10 l/min) l 245 Standby heat loss according to EN (at 65 C) kwh/24h 1,68 Maximum pressure bar 10

6 PWZS / 3~400V PWZS 62H3S technical data 3~400V PWZS 62H3S limits of use heating circuit return max I heating circuit flow max. C 20 I 60 heat source C additional operating points B0W65 sound sound pressure level at 1m distance from the edge of the unit db(a) 31 sound power levell according to EN12102 db 43 heat source volume flow: minimum throughout ı nominal throughout analogue B0W35 ı maximum throughout l/h 900 ı 1350 ı 2000 free external pressure heat pump p (with cooling pk) with Monoethylenglykol (25%) ı volume flow bar (bar) ı l/h 0,6 ( ) ı 1350 approved anti-freeze Monoethylenglykol I Propylenglykol I Methanol I Ethanol frostproof up to C -13 maximum operating pressure bar 3 I I I heating circuit volume flow: minimum throughout ı nominal throughout analogue B0W35 ı maximum throughout l/h 500 ı 1000 ı 1250 free external pressure heat pump p (with cooling pk) ı volume flow bar (bar) ı l/h (0,68) ı 1000 maximum operating pressure bar 3 general unit data total weight (with cooling) kg (kg) 220 ( ) weight Box kg 95 weight Tower kg 125 refrigerant type ı refrigerant capacity ı kg R410A ı 1,57 domestic hot watertank net volume l 186 impressed current anode integrated domestic hot water temperature in pure heat pump mode bis C 58 domestic hot water temperature with electric heating element bis C 65 delivery rate according to EN (40 C at with withdrawal10 l/mat) l 240 standby heat loss according to EN (at 65 C) kwh/24h 1,68 Maximum pressure bar 10

7 PWZS / 3~400V PWZS 82H3S technical data 3~400V PWZS 82H3S limits of use heating circuit return min I heating circuit flow max. C 20 I 60 heat source C Additional operating points B0W65 sound Sound pressure level at 1m distance from the edge of the unit db(a) 31 Sound power level according to EN12102 db 43 heat source volume flow: minimum throughout ı nominal throughout analogue B0W35 ı maximum throughout l/h 1200 ı 1750 ı 2600 free external pressure heat pump p (with cooling pk) with Monoethylenglykol (25%) ı volume flow bar (bar) ı l/h 0,7 ( ) ı 1750 approved anti-freeze Monoethylenglykol I Propylenglykol I Methanol I Ethanol frostproof up to C -13 Maximum operating pressure bar 3 I I I heating circuit volume flow: minimum throughout ı nominal throughout analogue B0W35 ı maximum throughout l/h 650 ı 1300 ı 1600 free external pressure heat pump p (with cooling pk) ı volume flow bar (bar) ı l/h (0,55) ı 1300 Maximum operating pressure bar 3 general unit data Total weight (with cooling) kg (kg) 235 ( ) weight Box kg 110 weight Tower kg 125 refrigerant type ı refrigerant capacity ı kg R410A ı 1,76 domestic hot watertank net volume l 186 impressed current anode integrated domestic hot water temperature in pure heat pump mode bis C 57 domestic hot water temperature with electric heating element bis C 65 delivery rate according to EN (40 C at with withdrawal10 l/mat) l 235 standby heat loss according to EN (at 65 C) kwh/24h 1,68 Maximum pressure bar 10

8 PWZS / 3~400V PWZS 102H3S technical data 3~400V PWZS 102H3S limits of use heating circuit return max I heating circuit flow max. C 20 I 60 heat source C additional operating points B0W65 sound sound pressure level at 1m distance from the edge of the unit db(a) 31 sound power levell according to EN12102 db 43 heat source volume flow: minimum throughout ı nominal throughout analogue B0W35 ı maximum throughout l/h 1500 ı 2200 ı 3300 free external pressure heat pump p (with cooling pk) with Monoethylenglykol (25%) ı volume flow bar (bar) ı l/h 0,85 ( ) ı 2200 approved anti-freeze Monoethylenglykol I Propylenglykol I Methanol I Ethanol frostproof up to C -13 maximum operating pressure bar 3 I I I heating circuit volume flow: minimum throughout ı nominal throughout analogue B0W35 ı maximum throughout l/h 800 ı 1600 ı 2000 free external pressure heat pump p (with cooling pk) ı volume flow bar (bar) ı l/h 0,5 ( ) ı 1600 maximum operating pressure bar 3 general unit data Total weight (with cooling) kg (kg) 240 ( ) weight Box kg 115 weight Tower kg 125 Refrigerant type ı refrigerant capacity ı kg R410A ı 2,02 domestic hot watertank net volume l 186 impressed current anode integrated domestic hot water temperature in pure heat pump mode bis C 56 domestic hot water temperature with electric heating element bis C 65 delivery rate according to EN (40 C at with withdrawal10 l/mat) l 230 standby heat loss according to EN (at 65 C) kwh/24h 1,68 Maximum pressure bar 10

9 PWZS / 3~400V PWZS 122H3S technical data 3~400V PWZS 122H3S limits of use heating circuit return max I heating circuit flow max. C 20 I 60 heat source C additional operating points B0W65 sound sound pressure level at 1m distance from the edge of the unit db(a) 31 sound power levell according to EN12102 db 43 heat source volume flow: minimum throughout ı nominal throughout analogue B0W35 ı maximum throughout l/h 1900 ı 2800 ı 4200 free external pressure heat pump p (with cooling pk) with Monoethylenglykol (25%) ı volume flow bar (bar) ı l/h 0,65 ( ) ı 2800 approved anti-freeze Monoethylenglykol I Propylenglykol I Methanol I Ethanol frostproof up to C -13 maximum operating pressure bar 3 I I I heating circuit volume flow: minimum throughout ı nominal throughout analogue B0W35 ı maximum throughout l/h 1050 ı 2050 ı 2600 free external pressure heat pump p (with cooling pk) ı volume flow bar (bar) ı l/h 0,3 ( ) ı 2050 maximum operating pressure bar 3 general unit data total weight (with cooling) kg (kg) 245 ( ) weight Box kg 120 weight Tower kg 125 refrigerant type ı refrigerant capacity ı kg R410A ı 2,40 domestic hot watertank net volume l 186 impressed current anode integrated domestic hot water temperature in pure heat pump mode bis C 55 domestic hot water temperature with electric heating element bis C 65 delivery rate according to EN (40 C at with withdrawal10 l/mat) l 225 standby heat loss according to EN (at 65 C) kwh/24h 1,68 Maximum pressure bar 10

10 PWZS / 3~ 400V weight overview weight and dimensions3~ 400V weight [kg] type gross net box package PWZS42H3S PWZS62H3S PWZS82H3S PWZS102H3S PWZS122H3S Measures gross [mm] Measures net [mm] Measures Box type H W D H H (type) W D H W D PWZS42H3S PWZS62H3S PWZS82H3S PWZS102H3S PWZS122H3S

11 PWZS / overview 3~230V type overview 3~230V heating capacity at kw at B0/W35 COP at B0/W35 PWZS 42H2S 4,6 4,6 PWZS 62H2S 5,8 4,8 PWZS 82H2S 7,5 4,8 PWZS 102H2S 10,3 4,8 PWZS 132H2S 13,0 4,7

12 PWZS/ nomenclature nomenclature (e.g.: PWZS 132H2S) P Pro W heat Z station S brine xx2 heating capacity at B0/W35 (e.g.:132 = 13kW at B0/W35) H heating 2 supply voltage 3~230V S stainless steel tank

13 PWZS / 3~230V PWZS 42H2S technical data 3~230V PWZS 42H2S limits of use heating circuit return max I heating circuit flow max. C 20 I 60 heat source C additional operating points B0W65 sound sound pressure level at 1m distance from the edge of the unit db(a) 31 sound power levell according to EN12102 db 43 heat source volume flow: minimum throughout ı nominal throughout analogue B0W35 ı maximum throughout l/h 700 ı 1050 ı 1600 free external pressure heat pump p (with cooling pk) with Monoethylenglykol (25%) ı volume flow bar (bar) ı l/h 0,6 ( ) ı 1050 approved anti-freeze Monoethylenglykol I Propylenglykol I Methanol I Ethanol frostproof up to C -13 maximum operating pressure bar 3 I I I heating circuit volume flow: minimum throughout ı nominal throughout analogue B0W35 ı maximum throughout l/h 450 ı 850 ı 1300 free external pressure heat pump p (with cooling pk) ı volume flow bar (bar) ı l/h (0,7) ı 850 maximum operating pressure bar 3 general unit data total weight (with cooling) kg (kg) 215 ( ) weight Box kg 90 weight Tower kg 125 refrigerant type ı refrigerant capacity ı kg R410A ı 1,20 domestic hot watertank net volume l 186 impressed current anode integrated domestic hot water temperature in pure heat pump mode bis C 59 domestic hot water temperature with electric heating element bis C 65 delivery rate according to EN (40 C at with withdrawal10 l/mat) l 245 standby heat loss according to EN (at 65 C) kwh/24h 1,68 Maximum pressure bar 10

14 PWZS / 3~230V PWZS 62H2S technical data 3~230V PWZS 62H2S limits of use heating circuit return max I heating circuit flow max. C 20 I 60 heat source C additional operating points B0W65 sound sound pressure level at 1m distance from the edge of the unit db(a) 31 sound power levell according to EN12102 db 43 heat source volume flow: minimum throughout ı nominal throughout analogue B0W35 ı maximum throughout l/h 900 ı 1350 ı 2000 free external pressure heat pump p (with cooling pk) with Monoethylenglykol (25%) ı volume flow bar (bar) ı l/h 0,6 ( ) ı 1350 approved anti-freeze Monoethylenglykol I Propylenglykol I Methanol I Ethanol frostproof up to C -13 maximum operating pressure bar 3 I I I heating circuit volume flow: minimum throughout ı nominal throughout analogue B0W35 ı maximum throughout l/h 500 ı 1000 ı 1250 free external pressure heat pump p (with cooling pk) ı volume flow bar (bar) ı l/h 0,68 ( ) ı 1000 maximum operating pressure bar 3 general unit data total weight (with cooling) kg (kg) 220 ( ) weight Box kg 95 weight Tower kg 125 refrigerant type ı refrigerant capacity ı kg R410A ı 1,20 domestic hot watertank net volume l 186 impressed current anode integrated domestic hot water temperature in pure heat pump mode bis C 58 domestic hot water temperature with electric heating element bis C 65 delivery rate according to EN (40 C at with withdrawal10 l/mat) l 240 standby heat loss according to EN (at 65 C) kwh/24h 1,68 Maximum pressure bar 10

15 PWZS / 3~230V PWZS 82H2S technical data 3~230V PWZS 82H2S limits of use heating circuit return max I heating circuit flow max. C 20 I 60 heat source C additional operating points B0W65 sound sound pressure level at 1m distance from the edge of the unit db(a) 31 sound power levell according to EN12102 db 43 heat source volume flow: minimum throughout ı nominal throughout analogue B0W35 ı maximum throughout l/h 1200 ı 1750 ı 2600 free external pressure heat pump p (with cooling pk) with Monoethylenglykol (25%) ı volume flow bar (bar) ı l/h 0,7 ( ) ı 1750 approved anti-freeze Monoethylenglykol I Propylenglykol I Methanol I Ethanol frostproof up to C -13 maximum operating pressure bar 3 I I I heating circuit volume flow: minimum throughout ı nominal throughout analogue B0W35 ı maximum throughout l/h 650 ı 1300 ı 1600 free external pressure heat pump p (with cooling pk) ı volume flow bar (bar) ı l/h 0,55 ( ) ı 1300 maximum operating pressure bar 3 general unit data total weight (with cooling) kg (kg) 235 ( ) weight Box kg 110 weight Tower kg 125 refrigerant type ı refrigerant capacity ı kg R410A ı 1,64 domestic hot watertank net volume l 186 impressed current anode integrated domestic hot water temperature in pure heat pump mode bis C 57 domestic hot water temperature with electric heating element bis C 65 delivery rate according to EN (40 C at with withdrawal10 l/mat) l 235 standby heat loss according to EN (at 65 C) kwh/24h 1,68 Maximum pressure bar 10

16 PWZS / 3~230V PWZS 102H2S technical data 3~230V PWZS 102H2S limits of use heating circuit return max I heating circuit flow max. C 20 I 60 heat source C additional operating points B0W65 sound sound pressure level at 1m distance from the edge of the unit db(a) 31 sound power levell according to EN12102 db 43 heat source volume flow: minimum throughout ı nominal throughout analogue B0W35 ı maximum throughout l/h 1650 ı 2450 ı 3650 free external pressure heat pump p (with cooling pk) with Monoethylenglykol (25%) ı volume flow bar (bar) ı l/h 0,77 ( ) ı 2450 approved anti-freeze Monoethylenglykol I Propylenglykol I Methanol I Ethanol frostproof up to C -13 maximum operating pressure bar 3 I I I heating circuit volume flow: minimum throughout ı nominal throughout analogue B0W35 ı maximum throughout l/h 900 ı 1800 ı 2250 free external pressure heat pump p (with cooling pk) ı volume flow bar (bar) ı l/h 0,45 ( ) ı 1800 maximum operating pressure bar 3 general unit data total weight (with cooling) kg (kg) 240 ( ) weight Box kg 115 weight Tower kg 125 refrigerant type ı refrigerant capacity ı kg R410A ı 1,80 domestic hot watertank net volume l 186 impressed current anode integrated domestic hot water temperature in pure heat pump mode bis C 56 domestic hot water temperature with electric heating element bis C 65 delivery rate according to EN (40 C at with withdrawal10 l/mat) l 230 standby heat loss according to EN (at 65 C) kwh/24h 1,68 Maximum pressure bar 10

17 PWZS / 3~230V PWZS 132H2S technical data 3~230V PWZS 132H2S limits of use heating circuit return max I heating circuit flow max. C 20 I 60 heat source C additional operating points B0W65 sound sound pressure level at 1m distance from the edge of the unit db(a) 31 sound power levell according to EN12102 db 43 heat source volume flow: minimum throughout ı nominal throughout analogue B0W35 ı maximum throughout l/h 2050 ı 3050 ı 4500 free external pressure heat pump p (with cooling pk) with Monoethylenglykol (25%) ı volume flow bar (bar) ı l/h 0,55 ( ) ı 3050 approved anti-freeze Monoethylenglykol I Propylenglykol I Methanol I Ethanol frostproof up to C -13 maximum operating pressure bar 3 I I I heating circuit volume flow: minimum throughout ı nominal throughout analogue B0W35 ı maximum throughout l/h 1150 ı 2250 ı 2800 free external pressure heat pump p (with cooling pk) ı volume flow bar (bar) ı l/h 0,25 ( ) ı 2250 maximum operating pressure bar 3 general unit data total weight (with cooling) kg (kg) 245 ( ) weight Box kg 120 weight Tower kg 125 refrigerant type ı refrigerant capacity ı kg R410A ı 2,13 domestic hot watertank net volume l 186 impressed current anode integrated domestic hot water temperature in pure heat pump mode bis C 55 domestic hot water temperature with electric heating element bis C 65 delivery rate according to EN (40 C at with withdrawal10 l/mat) l 225 standby heat loss according to EN (at 65 C) kwh/24h 1,68 Maximum pressure bar 10

18 PWZS / 3~ 230V weight overview weight and dimensions3~ 230V weight [kg] type gross net box package PWZS42H2S PWZS62H2S PWZS82H2S PWZS102H2S PWZS132H2S Measures gross [mm] type H W D H Measures net [mm] Measures Box H (type) W D H W D PWZS42H2S PWZS62H2S PWZS82H2S PWZS102H2S PWZS132H2S

19 PWZS / integrated components integrated components overflow valve switching valve heating / domestic hot water preparation coated with foam 186 litres stainless steel-hot water tank water heater incl. power control electronic switch box efficient PWM-heatingrespectively hot water - circulation pump

20 PWZS / integrated components integrated components shut-off valves with quick release fastener for removable refrigeration circuit-module box empty electric conduits removable, isolierte refrigeration circuit-module box with Führungsschienen

21 PWZS / refrigeration circuit-module box refrigeration circuit-module box support lugs heat source-entry heat source-output heating-return heating-flow vibration decoupling vibration decoupling evaporator condenser compressor filling and draining tap heating efficient PWM-heat source-circulation pump filling and draining tap heat source

22 PWZS / refrigeration circuit-module box refrigeration circuit-module box side view front view top view W x H x D: 535 x 585 x 590 mm PWZS 42/62/82 H3S without terminal box (without soft starter)

23 PWZS / removal and installation of the refrigeration-module box removal and installation of the refrigeration-module box for transport Remove connection cable at the plug Remove insulation of the heat source connections at the quick release fastener Remove quick release fastener respectively screw connection (left connection/ heating-flow) and disconnect plug connection Twist shut-off valves sideways Remove retaining screws at the lateral facade Pull out the box and transport with support lugs Installation has to be made in reverse order Replacement insulation for the heat source connection in the scope of delivery

24 PWZS / installation with quick release fastener installation with quick release fastener Use for installation acid-free lubricant (e.g.leak locator spray,...) Do not damage the o-rings when putting together the components(6 replacemento-rings in the scope of delivery) Fix components with quick release fastener

25 PWZS / connections connections heat source-entry Cu28mm / 1 IG heating-flow Cu28mm / 1 IG heating-safety valve 3 bar cable bushing Cold water-entry 3/4 AG hot wateroutput 3/4 AG heat source-output Cu28mm / 1 IG heating-return Cu28mm / 1 IG preinstalled load cable (ca.1m length at empty conduit)

26 PWZS / heat source connection heat source connection Because of flexibel connections and appropriate integrated decoupling hoses at the refrigeration circuitmodule box, there is the possibility to turn the connections of the heat source at the back side of the heat pump 90 left respectively right anti-freeze (concentration max.50%) that can be used: Glykol Prepared heating water Ethanol Methanol 90 90

27 VDI 2035 / ph-value ph-value concentration of hydrogen ions in a liquid attention: In aluminium material the ph-value is to be limited to max. 8,5 Highly alkaline VDI 2035 ph 8,2 10, neutral Slightly acidic Highly acidic Slightly alkaline Quelle: Grünbeck

28 VDI 2035 / sheet 1 (softening) VDI 2035 sheet 1 (softening) Total heating capacity Total hardness dh Depending on the specific system volume < 50 l/kw 50 l/kw 50 kw 11,2 dh < 0,11 dh > 50 kw und 200 kw 8,4 dh < 0,11 dh > 200 kw und 600 kw < 0,11 dh < 0,11 dh > 600 kw < 0,11 dh < 0,11 dh

29 VDI 2035 / sheet 2 (desalting) VDI 2035 sheet 2 (desalting) low-salt saline electrical conductivity at 25 C in µs/cm < appearance Free of sedimental matter ph - value at 25 C 8,2 10,0 Oxygen in mg/l < 0,1 < 0,02

30 PWZS / hycraulic components hycraulic components Safety package heat source optional expansion vessle cap valve safety module Safety package heating optional expansion vessle cap valve safety module separation tank- and tanks in series integration possible

31 PWZS / accessory pack in scope of delivery accessory-pack in scope of delivery cover control unit wall bracket control unit control unit fixing material wall bracket replacementinsulation for heat source shut-off valves safety valve heating Tube connections 28mm clamping ring / 1 IG outdoor sensor replacement gaskets

32 PWZS / transport concept transport concept refrigeration circuit-module box on delivery from the factory integrated in the device Removable for easier transport Tip refrigeration circuit-module box max. 45 at transport

33 PWZS / controller-control unit controller-control unit Controller control unit and wall bracket in the scope of delivery Put Lin-Bus-cable (2m length at back wall) through empty conduit at the back wall and connect it with control unit Max. cable length: 30m (from board to control unit to RBE) Bracket of control unit for the start up at the open heat station available wall bracket

34 PWZS / controller-control unit installation at the facade cable bushing Ø28mm fastening screws cable straps cable clip Are included in the scope of delivery

35 Lux 2.1 / control unit control unit RS485 for connection of the room control unit (RBE) net work Lin-Bus Connection to the control board

36 Lux / 2.1 PWZS Luxtronik 2.1 PWZS 1x I/O MAX integrated in the heat pump 1x immersion heater board Plus 1x expansion board for additional control menus Connection via Bus-cable Software 3.XX

37 Lux 2.1 / I/O MAX I/O MAX (indoorinstallation) internal sensor inputs Businterface control unit analogue outputs fuses 6,3A (Relais) 1,6A (Trafo) analogue inputs control voltage internal 230V inputs and outputs 230V outputs 230V distribution (constant current) 230V inputs connection to the PWMcirculation pump (contact point) External sensor inputs

38 Lux 2.1 / terminal assignment PWZS terminal assignment PWZS outputs 230V OUT 5 VBO heat source circulation pump OUT 6 ZW1 additional heat generator 1 OUT 10 ZW2 additional heat generator 2 OUT 11 ZIP circulation pump OUT 12 FP1 underfloor heating circulation pump 1 OUT 13 MZ1 mixer 1 close OUT 14 MA1 mixer 1 open OUT 15 ZUP Additional circulation pump OUT 16 HUP circulation pump heating circuit OUT 17 BUP switching valve domestic hot water inputs 230V at 3 MOT motor circuit-breaker at 4 ASD defrosting, brine pressure, flow rate at 5 EVU1 utility lock at 6 EVU2 utility lock at 7 STB/FBH safety temperature limiter outputs PWM PWM 1 BOSUP heat source circulation pump PWM 2 HUP/ZUP heating- / additional circulation pump inputs 5V NTC 6 TWA Sensor heat source output NTC 8 TRL ext Sensor return external NTC 9 CW coding heat pump NTC 10 TA outdoor sensor NTC 12 TB1 Sensor mixing circuit 1 NTC 13 TVL Sensor flow NTC 14 TRL Sensor return NTC 15 TBW Sensor domestic hot water

39 PWZS / terminal scheme PWZS 400V terminal scheme PWZS 400V

40 PWZS / terminal scheme PWZS 230V terminal scheme PWZS 230V

41 PWZS / 1x cable/ 3x cable(pwzs H3S) 1x cable/ 3x cable(pwzs H3S) PE N Pull out preinstalled load cable in front and pull in 3x load cable simultaneously from above Pay attention to appropriate fuse protection depending on connection Connect single wires after specification (see right) For connection to 3x load line the 4 jumpers of L1, L2 and L3 need to be removed 400V immersion heater 400V compressor 400V control system230v L3 L2 L1 PE PE PE NSt NH 1L3H L3V 1L2H L2V 1L1H L1V LSt

42 PWZS / 1x cable/ 3x cable(pwzs H2S) 1x cable/ 3x cable(pwzs H2S) Pull out preinstalled load cable in front and pull in 3x load cable simultaneously from above Pay attention to appropriate fuse protection depending on connection Connect single wires after specification (see right) For connection to 3x load line the 4 jumpers of L1, L2 and L3 need to be removed 230V immersion heater 230V compressor 230V control system230v L1 L2 L3 PE PE LSt L1V 1L1H N1 N2 1L2H 1L3H PESt PE

43 Lux 2.1 / immersion heater control PWZS immersion heater control PWZS Under following menu item the capacity of the immersion heater can be adjusted in 0,5kW steps: Service / settings / System settings

44 Lux 2.1 / immersion heater control PWZS immersion heater control PWZS 9kW 9kW the immersion heater is controlled permanently during a 10 sec. sequence time, because of that an output of 9kW is generated sec. sequence time 4,5kW 10 sec. sequence time 4,5kW At a required output of for example 4,5kW the sequence time is cut in half and the immersion heater is switchen on and off for every 5 sec sec. sequence time 5 sec. 5 sec. 10 sec. sequence time 5 sec. 5 sec

45 Lux 2.1 / efficiency pump PWZS efficiency pump PWZS Setting of the pump output via xxx% set value flow rate nominal and minimum is displayed in l/h efficiency pump nominal: The value is traversed while the compressor is running efficiency pump minimum: The value is traversed while the compressor is not running Ventil.-BOSUP: This value affects the heat source flow rate

46 PWZS / dimension sheet dimension sheet 1 heating water output 28x1 or Rp1 2 heat source entry 28x1 or Rp1 3 empty conduit for electric -/ sensor cable 4 safety valve heating circuit (in accessories kit) 5 heat source output 28x1 or Rp1 6 heating water entry 28x1 or Rp1 7 hot water R3/4 external thread 8 Kaltwater R3/4 external thread 9 supply 1m (at empty conduit for electric cable) 10 Lin-Bus cable (2m from device) 11 control unit for wall mounting (in accessories kit)

47 PWZS / possibilities for installations possibilities for installations

48 PWZS / possibilities for installations possibilities for installations

49 PWZS / possibilities for installations possibilities for installations

50 PWZS / components refrigeration circuit components refrigeration circuit condenser evaporator compressor Sensor suction gas in front of compressor tube heat exchanger Soldered tube on tube Hot gas sensor High pressure sensor High pressure pressostat filter dryer Low pressure sensor stepping motor Measuring points manometer panel Attention high pressures (R410A) Expansions-valve

51 PWZS / Hydraulic module box Hydraulic module box heating water output flow heating water Entry return Sensor heat source output sensor heat source entry PWM heat source efficiency pump emptying heating water Emptying heat source condensate drain

52 PWZS / refrigeration circuit refrigeration circuit heating water Aus heating water Eat brine Eat brine Aus 1 compressor 2 condenser 3 electronic expansion valve 4 evaporator 5 Schrader valve 6 intermedieate heat exchanger 7 filter dryer 8 domestic hot water switching valve 9 low pressure sensor 10 High pressure controller 11 hot gas sensor 12 flow temperature sensor 13 return temperature sensor 14 heat source entry temperature sensor 15 heat source output temperature sensor 16 safety valve 17 Heating circulation pump 18 domestic hot water tank 19 filling / emptying equipment 20 heat source circulation pump 21 excess pressure limiter 22 Electrical additional heating 23 angle valve 24 shut-off valve straight 25 high pressure sensor Temp.sensor overheating in front of 26compressor

53 Thank you very much for your attention!

Heat Pumps. Compact. Device Information. Operating manual supplement. LWC Series

Heat Pumps. Compact. Device Information. Operating manual supplement. LWC Series Device Information UK Air/Water Operating manual supplement Compact Heat Pumps LWC Series Please read first The Special Version Device Information is a component of the product. It complements the operating

More information

Operating Manual UK. air/water. We reserve the right to make technical changes bUK Translation of the operating manual

Operating Manual UK. air/water. We reserve the right to make technical changes bUK Translation of the operating manual Operating Manual UK air/water Heat Pumps Outdoor Installation nibe TM AP-AW0 We reserve the right to make technical changes. 800bUK Translation of the operating manual Please read first This operating

More information

Accessory for heat pumps. Operating Manual. Wall-mounted controller bUK Translation of the operating manual

Accessory for heat pumps. Operating Manual. Wall-mounted controller bUK Translation of the operating manual Accessory for heat pumps Operating Manual Wall-mounted controller UK 83058800bUK Translation of the operating manual Table of Contents About this operating manual...3 Validity...3 Reference documents...3

More information

Technical data LA 60TU

Technical data LA 60TU Technical data LA 6TU Device information LA 6TU Design - Heat source Outside air - Model Universal design - Regulation - Thermal energy metering Integrated - Installation location Outdoors - Performance

More information

Technical data LA 28TBS

Technical data LA 28TBS Technical data LA 28TBS Device information LA 28TBS Design - Heat source Outside air - Model Universal design - Regulation - Thermal energy metering Integrated - Installation location Outdoors - Performance

More information

Technical data LA 60TUR+

Technical data LA 60TUR+ Technical data LA 6TUR+ Device information LA 6TUR+ Design - Heat source Outside air - Model Universal design reversible - Regulation - Thermal energy metering Integrated - Installation location Outdoors

More information

Professional. Operating Instructions UK. Brine/Water. Heat pumps NIBE TM AP-BW30

Professional. Operating Instructions UK. Brine/Water. Heat pumps NIBE TM AP-BW30 Operating Instructions UK Brine/Water Professional Heat pumps NIBE TM AP-BW30 We reserve the right to make technical changes. 83050906bUK Translation of the operating manual Please read first These operating

More information

Technical data LA 9S-TU

Technical data LA 9S-TU Technical data LA 9S-TU Device information LA 9S-TU Design - Heat source Outside air - Model Universal design - Regulation - Thermal energy metering Integrated - Installation location Outdoors - Performance

More information

Technical Data. Danfoss DHP-C. Provides heating, cooling and hot water TWS technology provides hot water quickly with low operating

Technical Data. Danfoss DHP-C. Provides heating, cooling and hot water TWS technology provides hot water quickly with low operating Technical Data Danfoss DHP-C Provides heating, cooling and hot water TWS technology provides hot water quickly with low operating costs A built in 180 litre water tank Main parts... 2 Bipack contents...

More information

Starting current with soft starter Fuse protection. Connection heating Seal of approval MCS (valid until)

Starting current with soft starter Fuse protection. Connection heating Seal of approval MCS (valid until) Data sheet LA 16MS Air-to-water heat pump with deflector hoods Max. flow temperature: 58 C Casing colour: White aluminium (similar to RAL 9006) Air-to-water heat pump for outdoor installation with external

More information

Data sheet SI 24TE. Brine-to-water heat pump with two performance levels

Data sheet SI 24TE. Brine-to-water heat pump with two performance levels Data sheet SI 24TE Brine-to-water heat pump with two performance levels Order reference: SI 24TE Installation location: Indoors Flow temperature max 60 C Casing, powder-coated Heat pump for heating purposes

More information

Product Range Overview 2010

Product Range Overview 2010 Product Range Overview Renewable Energies Heat Pumps Solar Thermal Systems Domestic Heating Products Heatpumps Solar Thermal Systems Domestic Heating Systems Contents Heat pump for heating purposes air

More information

Inverter scroll compressors VZH

Inverter scroll compressors VZH Application guidelines Inverter scroll compressors VZH028-035-044 R410A http://cc.danfoss.com VZH028-035-044 - single compressors VZH scroll specificities...6 Inverter compressors...7 Compressor size...7

More information

Starting current with soft starter Fuse protection

Starting current with soft starter Fuse protection Data sheet LIH 26TE High temperature air-to-water heat pump Max. flow temperature: 75 C Casing colour: White (similar to RAL 9003) Brown-red design screen (RAL 3011) Heat pump for heating purposes for

More information

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser Vitocal 300-A, type AWC-I and AW-O.1 Product description A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser & High operational reliability,

More information

Technical data. Danfoss DHP-A

Technical data. Danfoss DHP-A Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs

More information

Brine/water heat pumps. Operating Manual SWC V H hUK Translation into English of the original German operating manual

Brine/water heat pumps. Operating Manual SWC V H hUK Translation into English of the original German operating manual Brine/water heat pumps Operating Manual SWC V H1 UK 83057100hUK Translation into English of the original German operating manual Contents 1 About this operating manual...3 1.1 Validity...3 1.2 Reference

More information

WZS 82(H)(K)3M 20 I B0W I I I (263) (288) 7.0

WZS 82(H)(K)3M 20 I B0W I I I (263) (288) 7.0 WZS 4(H)(K)M WZS 6(H)(K)M WZS 8(H)(K)M WZS (H)(K)M WZS 1(H)(K)M 0 I 60-5 5 B0W65 1 4 I I I -1 50 (58) 178 58 65 50 60 0 I 60-5 5 B0W65 1 4 I I I -1 55 (6) 178 58 65 50 60 0 I 60-5 5 B0W65 1 4 I I I -1

More information

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,

More information

Installation instructions Danfoss heat pump DHP-R

Installation instructions Danfoss heat pump DHP-R Installation instructions Danfoss heat pump DHP-R Table of contents DHP-R 1 Important information........................................................... 5 1.1 Refrigerant...5 1.2 Noise and vibrations...5

More information

50A KP 70A KP 90A KP 120A KP 150A KP 210A

50A KP 70A KP 90A KP 120A KP 150A KP 210A DC inverter all in one Model KP 5A KP 7A KP 9A KP 12A KP 15A KP 21A Power supply V/Hz/Ph 23/5/1 23/5/1 23/5/1 23/5/1 38/5/3 38/5/3 Nominal heating capacity kw 5 7 9 12 15 21 Nominal cooling capacity kw

More information

NIBE SPLIT ACVM 270 Air/water heat pump

NIBE SPLIT ACVM 270 Air/water heat pump NIBE SPLIT ACVM 270 Air/water heat pump NIBE SPLIT ACVM 270 system with complete indoor module NIBE SPLIT ACVM 270 is a complete modern heat pump system that offers effective technical energy saving and

More information

Starting current with soft starter Fuse protection

Starting current with soft starter Fuse protection Data sheet SI 14ME Brine-to-water heat pump Max. flow temperature: 58 C Casing colour: White (similar to RAL 9003) Brown-red design screen (RAL 3011) Heat pump for heating purposes for indoor installation

More information

EHS. EHS (Mono, LT, 50Hz)

EHS. EHS (Mono, LT, 50Hz) EHS EHS (Mono, LT, 50Hz) I. Products 1. Nomenclature.... 5 2. Line-up....... 7 1. Specification...... 9 2. Capacity Tables..... 13 3. Dimensional Drawings............. 19 4. Piping Diagrams..... 23 5.

More information

Inverter scroll compressors VZH single & manifold

Inverter scroll compressors VZH single & manifold Application guidelines Inverter scroll compressors VZH028-035-044 single & manifold R410A http://cc.danfoss.com Content VZH028-035-044 - single compressors... 4 VZH035-044 - hybrid manifolding... 48 FRCC.PC.034.A3.02

More information

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps. Air/water cooled chillers and heat pumps 41 303 kw General BETA ECHOS is a range of chillers and ductable air-water heat pumps. Configurations HP: Reversible heat pump LE: For connection to remote evaporator

More information

REMKO HYBRID HEAT PUMPS

REMKO HYBRID HEAT PUMPS REMKO HYBRID HEAT PUMPS Switch over to more efficiency even in old buildings HBW series 1-2014 Quality with systems THE HYBRID TECHNOLOGY Two technologies combined into one innovation "Hybrid comes from

More information

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

Geolo THE GROUND SOURCE HEAT PUMP PLUSES Geolo THE GROUND SOURCE HEAT PUMP PLUSES RENEWABLE TECHNOLOGIES Geolo is able to exploit the Energy present in the water and underground thanks to the geothermal exchangers. Soil and water absorb the solar

More information

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex. A-Class A-Rated Homes with Dimplex heat pumps Building Regulations and Part L Compliance made easy with Dimplex. The name you can trust. dimplex.ie AClass A4 Page Brochure-August 2016.indd 1 A-Class Heat

More information

Technical data. Danfoss DHP-L

Technical data. Danfoss DHP-L Technical data Danfoss DHP-L Heat pump with the same features as Danfoss DHP-H, but with separate hot water tank. Can reduce heating costs by more than 50 percent. Main parts... 2 Bipack contents... 3

More information

MMEngineering. Suction lifter. Lightning fast suction for lifting and moving. with only on vaccum line. Suction lifters Vacuum-operated

MMEngineering. Suction lifter. Lightning fast suction for lifting and moving. with only on vaccum line. Suction lifters Vacuum-operated 6 available sizes Integral suction lifter Accessories Lightning fast suction for lifting and moving with only on vaccum line s Vacuum-operated Integral suction lifter Compressed-air Page 3-01.. Page 3-02..

More information

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water Designed to replace a conventional boiler and produce domestic hot water Heating capacity : 16 to 25 Heating Hydraulic module ENVIRONMENTALLY HFC R4A PROTECTION DE FRIENDLY L'ENVIRONNEMENT USE CIAT is

More information

Starting current with soft starter Fuse protection. Heat source connection

Starting current with soft starter Fuse protection. Heat source connection Data sheet SI 17TE Brine-to-water heat pump max. flow temperature: 58 C Casing colour: white Brown-red design screen (RAL 3011) Heat pump for indoor installation with integrated regulation WPM 2007 plus.

More information

Technical description. Atec.

Technical description. Atec. www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

MAKING MODERN LIVING POSSIBLE. Technical description DHP-M.

MAKING MODERN LIVING POSSIBLE. Technical description DHP-M. MAKING MODERN LIVING POSSIBLE Technical description www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English

More information

Ground Source Heat Pumps

Ground Source Heat Pumps indoor installation Ground Source Heat Pumps heat pumps The heat pump specialist indoor installation Ground Source Heat Pumps heat pumps The heat pump specialist AlphaWeb compatible Simply control your

More information

ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website

ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website 17/04/2012 CI/SFB [56] www.dimplex.co.uk ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website The information is correct at time of downloading,

More information

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual u Air-to-Water Reverse Cycle Heat Pumps AQH 40 to 130 40 to 131 kw 45 to 141 kw Engineering Data Manual EDM AQH-W.3GB Date : November 2007 Supersedes : TM AQH-W.2GB/03.04 Specifications The Aqu@Logic air-to-water

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

High temperature air-to-water heat pumps

High temperature air-to-water heat pumps Designed to replace conventional boilers and produce domestic hot water 4 High temperature hot water (+65 C) 4 Winter operation (-20 C) 4 High energy efficiency (CP) 4 Compact and quiet 4 Scroll compressors

More information

CABINET PARTS For Model: KBFC42FTS03 (Stainless Steel)

CABINET PARTS For Model: KBFC42FTS03 (Stainless Steel) CABINET PARTS 42" BOTTOM MOUNT BUILT IN REFRIGERATOR 7 08 Litho In U.S.A. (mjb)(bay) 1 Part No. Rev. A CABINET PARTS 1 Literature Parts 2320682 Use & Care Guide W10205809 Energy Guide W10159834 Service

More information

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS ENGINEERING SPECIFICATIONS RH-12-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 12 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.

More information

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER Instruction Manual Model AMB-12H PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USING THIS UNIT. Table of Contents 1. SAFETY WARNINGS 2 2. CONSTRUCTION...

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

AQUASNAP JUNIOR 30RHV

AQUASNAP JUNIOR 30RHV High-Efficiency Air-To-Water Heat Pumps Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. AQUASNAP JUNIOR 3RHV 6-11

More information

T. +44 (0) E.

T. +44 (0) E. Twin Plate Heat interface unit for indirect heating and instantaneous domestic hot water with electronic thermostatic control. Designed for wall-mounting. Application The is the complete solution for hot

More information

Advance Split

Advance Split Engineering Data Manual Aqu@Scop Advance Split Air-to-Water DC Inverter Split Heat Pumps Models 005, 008, 012 & 014 2 to 16 kw Strength Points Most efficient heating technology with variable speed compressor.

More information

Planning guide. Atec.

Planning guide. Atec. www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

Economy Standard Comfort. Heat loss (W/K) Heat loss (kwh/24h) (3)

Economy Standard Comfort. Heat loss (W/K) Heat loss (kwh/24h) (3) 4 Technical Data The following tables and drawings provide an overview of the most important dimensions and properties of Solvis- Max Gas and SolvisMax Gas Pur. 4.1 Volumes and heat loss SX-356 SX-456

More information

CABINET PARTS For Model: KBLC36FTS06 (Stainless Steel)

CABINET PARTS For Model: KBLC36FTS06 (Stainless Steel) CABINET PARTS 36" BOTTOM MOUNT BUILT IN REFRIGERATOR 4 12 Litho In U.S.A. (mlg)(bay) 1 Part No. Rev. A CABINET PARTS 1 Literature Parts W10303987 Use & Care Guide W10205624 Energy Guide W10483322 Service

More information

HT V2 HT Split

HT V2 HT Split Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single

More information

WZH Ground source heat pumps

WZH Ground source heat pumps Ground source heat pumps infolinia: +48 691 262 691 +60 C C.O.P. 5,1 HP heat pumps are particularly suitable for applications that utilise well water or ground source probes. These units have been designed

More information

LZA High efficiency air to water heat pumps with HP compressor

LZA High efficiency air to water heat pumps with HP compressor High efficiency air to water heat pumps with HP compressor -10 C +43 C +60 C HP C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems

More information

ModuSat TP. Energy. Heat Interface Units

ModuSat TP. Energy. Heat Interface Units Energy Twin Plate Heat interface unit for indirect heating and instantaneous domestic hot water with electronic thermostatic control. Designed for wall-mounting. Application The is the complete solution

More information

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories > HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION Available range Unit type IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS Versions (heat recovery) VB Base

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

Dimplex High efficiency air-to-water heat pump for indoor installation. (Low temperature) Order reference

Dimplex High efficiency air-to-water heat pump for indoor installation. (Low temperature) Order reference Data sheet LI 9TU High efficiency air-to-water heat pump for indoor installation. Max. flow temperature: 60 C Casing colour: White (similar to RAL 9003) Brown-red design screen (RAL 3011) Heat pump for

More information

Danfoss Scroll for Refrigeration MLM / MLZ

Danfoss Scroll for Refrigeration MLM / MLZ s Danfoss Scroll for Refrigeration MLM / MLZ 50-60 Hz - R404A - R507 - R134a - R22 - R407A - R407F http://danfoss.us.com/ Contents Features... 6 Scroll compression principle... 7 The scroll compression

More information

Product Offering for 2017

Product Offering for 2017 Product Offering for 2017 Accelera 220 E / 300 E Made in EU (Slovakia) 3.05 & 3.39 EF (COP) from Energy Star respectively Updated electronics Displays temperatures and current tank content in Fahrenheit

More information

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5

More information

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS ENGINEERING SPECIFICATIONS RH-24-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 24 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.

More information

VIESMANN. Installation and service instructions VITOCAL 300-G. for contractors

VIESMANN. Installation and service instructions VITOCAL 300-G. for contractors Installation and service instructions for contractors VIESMANN Vitocal 300-G Type BW/BWS 301.A06 to A17, 5.9 to 17.0 kw Type WW 301.A06 to A17, 7.9 to 23.0 kw Heat pump, single and two-stage Type BWC 301.A06

More information

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017 Zeta Rev LN HP 10.2 Configured unit accessories 1PS - One user-side pump with tank LN - Low noise RG - Condensation control with fan speed regulator CSP - Set point compensation depending on external air

More information

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years

More information

Air Cooled Chillers & Heat Pumps WinPACK HE-A

Air Cooled Chillers & Heat Pumps WinPACK HE-A Air Cooled Chillers & Heat Pumps WinPACK HE-A TCAEY-THAEY 2110-4340 1 Air Cooled Chillers & Heat Pumps WinPACK HE-A TCAEY-THAEY 2110-4340 Cooling capacity: 91,6-345 kw Heating capacity: 110,5-357 kw Class

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating 2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER AIR-TO-WATER HEAT PUMP cooling - heating MINI CHILLER Highly efficient heat pump for summer and winter air conditioning. Ideal for residential and commercial

More information

HVS, Hydro Variable System Air cooled chiller

HVS, Hydro Variable System Air cooled chiller HVS, Hydro Variable System Air cooled chiller YDCC522H (-C) / YDCC972H (-C) / YOCC762H (-C) / YOCC1522H (-C) A complete range from 15 kw up to 72 kw Water Systems Features Variable capacity compressor

More information

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45 Plug & Heat heat pump Quick and easy to install For new homes or boiler backup operation 50 HFC R410A CERTIFIED BY CERTITA Heating capacity: 5.5 to 22 kw option CERTIFIED BY CERTITA 30/35-40/45 USE The

More information

DOMESTIC ICE MACHINE USER INSTRUCTION MANUAL MODEL TS-061

DOMESTIC ICE MACHINE USER INSTRUCTION MANUAL MODEL TS-061 DOMESTIC ICE MACHINE USER INSTRUCTION MANUAL MODEL TS-061 Page 1 of 8 Introduction This instruction manual covers the operation of versions of the Domestic Ice Machine Model TS-061 manufactured after April

More information

ECOFOREST GEOTERMIA. ecogeo. Ground/Air Source Heat Pumps.

ECOFOREST GEOTERMIA. ecogeo. Ground/Air Source Heat Pumps. ECOFOREST GEOTERMIA www.ecoforest.es comercial.geotermia@ecoforest.es Ground/Air Source Heat Pumps ecogeo ECOFOREST GEOTERMIA New company, 2010, Ecoforest Geotermia Manufacture of ground/air source heat

More information

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions TECHNICAL DATA SHEET HP08L-M-WEB Performance Data 1) A-7W35 A2W35 A10W35 A2W50 Heating capacity 8,67 kw 11,14 kw 14,91 kw 9,87 kw Cooling capacity 6,16 kw 8,58 kw 12,33 kw 6,43 kw Input 2,51 kw 2,56 kw

More information

Series HEATING HEATING Dimensions LxWxH [mm] 1150 x 400 x x 600 x 650. GMWW 10 plus

Series HEATING HEATING Dimensions LxWxH [mm] 1150 x 400 x x 600 x 650. GMWW 10 plus 38 Heat source water WATER Monovalent heating system with heat source water tv max. 65 C GOLF MIDI PLUS GOLF MAXI PLUS Series HEATING HEATING Dimensions LxWxH [mm] 1150 x 400 x 650 1150 x 600 x 650 Model

More information

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER

More information

CRIMSON & CRIMSON MAX

CRIMSON & CRIMSON MAX High efficiency water/water and geothermal heat pumps 5 114 General High efficiency water/water and geothermal heat pumps. Ideal for heating, cooling and production of domestic hotwater with total or partial

More information

A w rld of new product innovation new product launches

A w rld of new product innovation new product launches A w rld of new product innovation 2011 new product launches Welcome to our w rld Dimplex is proud to announce a set of new product ranges that significantly enhance our portfolio of renewable energy technologies.

More information

ModuSat TP. Energy. Heat Interface Units

ModuSat TP. Energy. Heat Interface Units Energy Twin Plate Heat interface unit for indirect heating and instantaneous domestic hot water with electronic thermostatic control. Designed for wall-mounting. Application The is the complete solution

More information

NIBE F2026 air/water heat pump. fresh air s free. NIBE F2026. Efficient scroll compressor that operates at temperatures down to -20 C.

NIBE F2026 air/water heat pump. fresh air s free. NIBE F2026. Efficient scroll compressor that operates at temperatures down to -20 C. NIBE F2026 air/water heat pump fresh air s free. Efficient scroll compressor that operates at temperatures down to -20 C. Automatic 2-step capacity regulator for the fan (not 6kW). Manufactured in three

More information

WARMTEPOMPEN DIMPLEX. POMPES À CHALEUR DIMPLEX.

WARMTEPOMPEN DIMPLEX. POMPES À CHALEUR DIMPLEX. WARMTEPOMPEN DIMPLEX. POMPES À CHALEUR DIMPLEX. 2016 Energy efficiency classes/general notes Simply individual. 1625 times over. Energy efficiency classes for heat pumps Y IJA IE IA Energy label The ErP

More information

SWP F12 F11. Terminals. Main contactor; mains power 3~PE/400V/50Hz. Terminals in heat pump switchbox UK831175

SWP F12 F11. Terminals. Main contactor; mains power 3~PE/400V/50Hz. Terminals in heat pump switchbox UK831175 SW 7 69 / SW 9H 56H Terminal diagram Information on fuses can be found in the technical data A5 -F -F BU DFS F HU I MA/MIS MZ/MIS X :,,, RFV TA TB TBW TR VBO X0-X4 X0 X0:,, ZU ZI ZW ZW/SST Hot water circulating

More information

ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website

ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website 17/04/2012 CI/SFB [56] www.dimplex.co.uk ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website The information is correct at time of downloading,

More information

Spare parts catalogue

Spare parts catalogue Spare parts catalogue 0020117283_00 GB 08/2011 Air water heat pump geotherm air geotherm VWL 45/1 A 230 V geotherm VWL 65/1 A 230 V geotherm VWL 75/1 A 230 V geotherm VWL 125/1 A 230 V geotherm VWL 155/1

More information

SyScroll 40 to 75 Air NEW

SyScroll 40 to 75 Air NEW Chiller Close Control Water terminals SyScroll 40 to 75 Air NEW Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual 40.0 to 76.0 kw 40.0 to 77.0 kw SyScroll 40-75 Air 3 Key points

More information

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with

More information

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating

More information

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery. PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 00 m /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION

More information

CABINET PARTS For Model: JS42CXFXDB00 (Etched Aluminum)

CABINET PARTS For Model: JS42CXFXDB00 (Etched Aluminum) CABINET PARTS 42" BUILT IN REFRIGERATOR 1 08 Litho In U.S.A. (mat) 1 Part No. Rev. A CABINET PARTS 1 Literature Parts W10151251 Use & Care Guide W10164079 Energy Guide W10159831 Service & Wiring Sheet

More information

CABINET PARTS For Model: KBLC36FTS04 (Stainless Steel)

CABINET PARTS For Model: KBLC36FTS04 (Stainless Steel) CABINET PARTS 36" BOTTOM MOUNT BUILT IN REFRIGERATOR 10 11 Litho In U.S.A. (mlg) (eeb) 1 Part No. Rev. A CABINET PARTS 1 Literature Parts W10303987 Use & Care Guide W10205624 Energy Guide W10159833 Service

More information

Storage tank size Rated volume [l] Actual volume [l]

Storage tank size Rated volume [l] Actual volume [l] 10 Technical Data Volumes and heat loss Storage tank size 356 456 656 756 956 Rated volume [l] 350 450 650 750 950 Actual volume [l] 365 448 623 695 886 Hot water standby volume [l] Economy Standard Comfort

More information

GeoCIAT Modular. Components. Heat pump Heating only, Glycol/water mix/water. Refrigerant and hydraulic module diagram. HomeConnect control.

GeoCIAT Modular. Components. Heat pump Heating only, Glycol/water mix/water. Refrigerant and hydraulic module diagram. HomeConnect control. Plug&Heat heat pump HomeConnect control For residential and tertiary applications Heating capacity (0/- C ): 5 to 9 kw Heating capacity (0/7 C ): 7 to kw Domestic 62 40A hot water Geo Cooling Modular Concept

More information

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB R407C EASY_R Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans 5,2 41,5 kw T_ESY_R_0508_GB EASY_R R407C INDEX WORKING LIMITS... 3 SERIES IDENTIFICATION... 4 MODEL

More information

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

Chiller units and air-water heat pumps RANGE OPERATING LIMITS Chiller units and air-water heat pumps Cooling capacity: Heating capacity: 6, to 6,6 kw 8, to 69,4 kw ENVIRONMENTALLY FRIENDLY HFC R407C PROTECTION DE L'ENVIRONNEMENT Silent and compact design Air-conditioning

More information

Blue Box Epsilon Echos +

Blue Box Epsilon Echos + Blue Box Epsilon Echos + 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Packaged version in 5 sizes Nominal cooling capacity (A35;W7): 6 26 kw Nominal heating

More information

UK arotherm Schematics and installation guide

UK arotherm Schematics and installation guide UK arotherm Schematics and installation guide Air to Water Heat Pumps (AWHP) Controls: VRC 700, VR 70, VR 91 The Vaillant heat pump booklet contains documentation to assist in the design, installation

More information

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV Amendment Sheet Code : M5ACV-2005-0002 Date : 08-05-2006 Superceded : M5ACV-2005-0001 Nomenclature Production spec variation Type of ref. connection X : Not applicable Electrical A : 220-240V/1Ph/50Hz

More information

GREENSOURCE INSTALLATION MANUAL AIR TO WATER HEAT PUMP WITH DOMESTIC HOT WATER DISTRIBUTION UNIT 6 KW, 7 KW AND 9.5 KW UK/IE (2010/01)

GREENSOURCE INSTALLATION MANUAL AIR TO WATER HEAT PUMP WITH DOMESTIC HOT WATER DISTRIBUTION UNIT 6 KW, 7 KW AND 9.5 KW UK/IE (2010/01) INSTALLATION MANUAL AIR TO WATER HEAT PUMP WITH DOMESTIC HOT WATER DISTRIBUTION UNIT GREENSOURCE 6 KW, 7 KW AND 9.5 KW 6 720 641 467-00.1I UK/IE 6 720 641 467(2010/01) TABLE OF CONTENTS TABLE OF CONTENTS

More information

KitchenAid Food Stream Solutions Classic and Integrated Series

KitchenAid Food Stream Solutions Classic and Integrated Series KitchenAid Food Stream Solutions Classic and Integrated Series KitchenAid Chapter list Installation Range overview Installation General Information Function Compressor Power Control Board Defrosting Heating

More information

CABINET PARTS. For Models: KBLC36FMS00 (Stainless Steel) 9 05 Litho In U.S.A. (kdj) Part No " BOTTOM MOUNT BUILT IN REFRIGERATOR

CABINET PARTS. For Models: KBLC36FMS00 (Stainless Steel) 9 05 Litho In U.S.A. (kdj) Part No  BOTTOM MOUNT BUILT IN REFRIGERATOR CABINET PARTS 36" BOTTOM MOUNT BUILT IN REFRIGERATOR 9 05 Litho In U.S.A. (kdj) 1 Part No. 1 Literature Parts LIT2266810 Use & Care Guide LIT2266819 Energy Label LIT2266830 Service & Wiring Sheet LIT628370

More information