1 TC-XX Series, TC-XX Series, TF- Series Two-Position Electric Duplex Room Thermostats These thermostats provide on-off control of heating/cooling systems. TC-XX Series, TC-XX Series, TF- Series Features: Separate units for C and F. All units except TC-4. - Parallel heat and/or cooling anticipation capability. - Dial stop pins to limit range. - Lock cover screw/sets available. - Agency approval. - Switch bases AT-2 and AT-3 available for custom applications. TC-8X and TC-9X. - Fan switch option standard C 68 F F 30 C TC-4 OFF LO HI HI MED OFF LO TC-86 TC-87 TC-88 TC-95 TC-99 * TC-9* TC-0X* TF- *Only TC-9 and TC -0X with factory-supplied metal cover are CSA approved. TC-9, TC-0X, TF- with Digital Thermometer Kit Installed Model Chart Application Setpoint Dial Range Differential Switch Refer to Ratings Table Connections Cover Dimensions In. (mm) H x W x D TC-4 TC-86 TC-87 TC-88 TC-87-6 TC-88-6 TC-95 TC-99 On/off control of unit heaters or motors. Sequenced onoff control of line voltage fan coil or zone valves on heating and cooling systems. On-off control of line voltage fan coil or zone valves on heating and cooling systems. to 86 F (0 to 30 C) Dual marked 55 to 85 F 3 to 29 C 55 to 85 F (3 to 29 C) Heat, 2 F (. C) Cool, 3 F (.7 C) Heat, 2 F Neutral, 2 F Cool, 2 F Heat,. C Neutral,. C Cool,. C.5 F (0.8 C) Heat, 2 (. C) Cool, 2 (. C) Neutral, 2 (. C) SPDT zero energy band SPDT zero energy band Color-coded Coded screw terminals and color-coded plastic with metal brushed bronze insert metal with metal brushed bronze insert 4-/2 x 2-3/4 x -/8 (4 x x 29) 4-3/8 x 2-3/4 x -5/8 ( x x 4) 38
2 TC-XX Series, TC-XX Series, TF- Series Model Chart (Continued) Application Setpoint Dial Range Differential a TC-0 55 to 85 F 2 F TC to 29 C C TC-0-0 a Low or line 55 to 85 F 2 F TC-02 voltage on-off 45 to 75 F 2 F control of fan TC-02-6 coils, fans, motor 7 to 23 C C TC-02-0 a starters, contactors, twoposition electric 2 F 45 to 75 F TC-02-2 b TC-03 actuators. 75 to 05 F TC to 39 C C TC-03-0 a 75 to 05 F 2 F TC-9 Low or line 55 to 85 F TC-9-6 TC-9-0 voltage on-off 3 to 29 C control of Heat, 2 (. C) heat/cool Cool, 2 (. C) systems such as 55 to 85 F Neutral, 2 (. C) TC-9-2 b 3 or 4 pipe unitary. Switch Refer to Ratings Table TF- 55 to 85 F 4 F SPDT Floating control floating off of one MF-233 TF series actuator. 3 to 29 C 2 C 24 Vac Connections Color-coded Cover plastic as standard Dimensions In. (mm) H x W x D 4-3/8 x 2-7/8 x -5/8 ( x 73 x 4) a b Heat anticipation model. Night depression model. with Standard Insert Insert Figure Standard Covers. F C TC-XXX-399 TC-XXX /64" Allen screw used to secure cover Figure 2 Options (for quantities of 24 or more each number) Add dash number (-XXX) suffix to base [part number of desired option]. For metal covers, specify TC2-XX. No cover option for TC-XX. 39
3 TC-XX Series, TC-XX Series, TF- Series Specifications Thermostats mounted on concrete walls or surfaces that change temperature slowly, have reduced response to changes in air temperature. Response is further delayed by guards that restrict air flow Anticipators to the thermostat. Anticipators are required (parallel for cooling, series or parallel for heating) for any of these conditions and in spaces intended for continuous occupancy; i.e., hotel guest rooms and offices. TC-8X Series Cooling is fixed. TF- Series Heating and cooling; factory-installed resistors are sized for Vac maximum. Fan switch TC-8X Series Marking: Low-Off a -Med-High. Marking: Off-Lo-Hi TC-9X Series a. Construction: Integral two-pole three-position. Sensing element Bimetal. Mounting Flush or 2 x 4 wall box. Locations NEMA Type. a Off position de-energizes thermostat and fan. Ratings. Volts (AC) Fan Switch Full Load Locked Volts (AC) Full Load Thermostat Contacts Locked Rotor Pilot Duty (VA) Non-Inductive TC-4 TC / /8 58.8/48 25/25 TC TC-87 TC-87-6 TC-87-7 TC-88 TC-88-6 TC-88-7 TC-95 TC-95-7 TC-99 TC-99-7 TC-0 TC-0-6 TC-0-0 TC-0-0 TC-02 TC-02-6 TC-02-0 TC-02-2 TC-02-7 TC-03 TC-03-6 TC-03-0 TC /240 6/3 36/8 20/240 24/20/240 3/.5 8/9 25.0/0.5 6/3 40 Heat, 4.4/4.4/2.2 Cool, 3.0/3.0/.5 Heat 26.4/26.4/3.2 Cool, 8/8/9 40/20/20 320
4 TC-XX Series, TC-XX Series, TF- Series Ratings (Continued). TC-9 TC-9-6 TC-9-0 TC-9-2 TC-9-7 TF- TF--6 TF--7 Volts (AC) Fan Switch Full Load Locked Volts (AC) 24/20/240 Full Load Heat, 4.4/4.4/2.2 Cool, 3.0/3.0/.5 Thermostat Contacts Locked Rotor Heat 26.4/26.4/3.2 Cool, 8/8/9 Pilot Duty (VA) 40/20/ at 24 Vac Non-Inductive Accessories AT-6 Series AT-0 AT-04 AT-4 AT-5 AT-546 AT-2 AT-3 AT-03 AT-04 AT-05 AT-55 AT-65 TOOL- TOOL-3 Description Brushed bronze cover plates. Lock cover kit. Dial stop pins (pins included with each unit). Plaster hole cover kit (small). Surface mounting base. Auxiliary mounting plate. Selector switch sub-base DP4T. Selector switch sub-base one DP4T, one DPDT. Wire guard. Cast aluminum guard. Calibration wrench. Contact burnishing tool. Typical Applications (Orange) Common Black makes ON temp. drop. Figure 3 TC-4 Switch Action and Lead Identification. (Orange) Common L Heat makes ON temp. drop. Black/ Night Depression Black/ Figure 4 TC-0X Series Switch Action and Lead Identification. 32
5 TC-XX Series, TC-XX Series, TF- Series Cooling Anticipator C Hi Med Off Low B 2 R Cooling () Heating () High (Yellow) Medium (Black) Low (Blue) L (Orange) Ground (Green) Thermostat. makes ON temp. drop. 2 Fan switch shown in off position. To Fan Motor Figure 5 TC-8X Series Switch Action and Terminal Identification. (Orange) L Heat makes ON temp. drop. Black/ Night Depression Black/ Figure 6 TC-9 Switch Action and Lead Identification. (Purple) Jumper B R 2 Thermostat. makes ON temp. drop. 2 Fan switch shown in low position. (Black) L Hi Low To Fan Motor Off Figure 7 TC-9X Series Switch Action and Terminal/Lead Identification. Orange TF- Heat Anticipator (Heat) CCW 3 MF-233 Actuator 24 Vac Max Draw 0.6 Amp Black/ Black/ Cool Anticipator (Cool) CW 2 COM Figure 8 TF- Switch Action and Typical Wiring. 322
PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE
Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface
More informationSchneider Electric Erie T155 Series
Schneider Electric Erie T Series Non-Digital, On/Off Thermostat General Instructions Application The T series thermostat provides on/off control for low voltage and line voltage valves, relays and fan
More informationTC-5231 Series, TC-5232, & TC-5241 Series
TC-5231 Series, TC-5232, & TC-5241 Series Low Temperature Thermostats General Instructions Application The TC-5231, TC-5232, and TC-5241 low temperature thermostats are used to control temperature in air
More informationCP CP
CP-8161-333 CP-8161-433 Electronic Programmable Controller Six Stage, Dual Setpoint General Instructions APPLICATION Electronic six stage programmable controller with proportional output for heating, cooling
More information59T, 66T Series Electric Water Heater Controls
, 66T Series Electric Water Heater Controls 8 Snap-Action Bimetal Discs in Both Controls The and 66T series controls are designed to meet the high electrical capacity requirements of electric water heaters.
More informationI N STALL AT ION & O PERATIO N MANUAL TA 1/ TA 2 CONTROLLER. Redefine your comfort zone.
I N STALL AT ION & O PERATIO N MANUAL TA 1/ TA 2 CONTROLLER IOM TA1/TA2 C O N T R O L L E R Table of Contents Table of Contents...2 List of Figures...3 List of Tables...3 Section 1 - General Information...4
More information59T, 66T Series Electric Water Heater Controls
, 66T Series Electric Water Heater Controls Snap-Action Bimetal Discs in Both Controls The and 66T series controls are designed to meet the high electrical capacity requirements of electric water heaters.
More informationRAB10 Series Two-pipe Fan Coil Room Thermostat with Manual Changeover
RAB10 Series Two-pipe Fan Coil Room Thermostat with Manual Changeover Document No. 155-524P25 ET RAB-1 Description Two-wire, gas diaphragm-based fan coil room thermostat with heating or cooling sequence
More informationTEMPERATURE & PRESSURE CONTROLS
TEMPERATURE & PRESSURE CONTROLS RANCO LUBE OIL PROTECTION CONTROLS These lube oil protection controls guard pressure-lubricated refrigeration compressors against major damage due to loss of oil pressure.
More informationEvaporative Cooling Controls... 1F51 / 8A18Z / 21D Thermostat Guards, Plastic... F Thermostat Guards, Metal... F29...
INDEX THERMOSTAT SECTION LOW VOLTAGE ELECTRONIC / DIGITAL 8 20 Description (s) Page(s) Emerson Big Blue 12 Touchscreen... 1F95 / 1F97... 8-9 Emerson Blue 6 Thermostats... 1F95 / 1F95EZ... 10-11 Emerson
More informationTK-1801, TK-1811 TK-1801, TKR-1811
TK-1801, TK-1811 TK-1801, TKR-1811 Pneumatic Zero Energy Band Room Thermostats General Instructions APPLICATION For proportional control of pneumatically-operated sequenced heating and cooling valves and/or
More informationPowers Controls ET 134 Low Temperature Detection Thermostat
Document No. 155-115P25 ET 134-20 Powers Controls ET 134 Low Temperature Detection Thermostat Description Features Product Numbers The Electric Low Temperature Detection Thermostat is a remote bulb instrument
More informationPowers TM Controls ET 134 Line Voltage Room Thermostats
Powers TM Controls ET 134 Line Voltage Room Thermostats Technical Instructions Document No. 155-017P25 ET 134-55 134-1083 134-1084 &134-1085 Exposed Knobs 134-1084 & 134-1085 Concealed Adjustment 134-1086
More informationPump-Down Controller MODEL 4052
Pump-Down Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4052 Pump-Down
More informationT834C Heating-Cooling Thermostat
M3375 M3375 TRADELINE T834C Heating-Cooling Thermostat Application T834C Thermostats control 4 to 30 Vac single-stage heating-cooling systems. See Table for specific models and applications. An spdt mercury
More informationCONTROLS THERMOSTATS Bulletin No November 2001 Supersedes September 2001 INNOVATOR PROGRAMMABLE THERMOSTATS ENGINEERING DATA
ENGINEERING DATA CONTROLS THERMOSTATS Bulletin No. 210125 November 2001 Supersedes September 2001 INNOVATOR PROGRAMMABLE THERMOSTATS L21 SERIES THERMOSTATS HEAT/COOL SYSTEMS Features (All Models): Extra
More informationQUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS
QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1-316-832-4357
More informationQUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS
QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS Note: This manual may also be used for 6536-871 series heat pumps if the 6535-3209 Replacement
More informationPump-Up Controller MODEL 4062
Pump-Up Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4062 Pump-Up
More informationINSTALLATION AND OPERATION MANUAL ANALOG ELECTRONIC CONTROLS VAV TERMINAL UNITS
INSTALLATION AND OPERATION MANUAL ANALOG ELECTRONIC CONTROLS VAV TERMINAL UNITS CTE-51 Series Thermostats: The CTE-51 series thermostats are designed to be used with the CSP-52 controller actuator. CTE-51
More informationfeatures Overview Powerstar Room Thermostats Description Applications Selection Guide Thermostats & Hygrostats A-3
Overview Proven to provide fast response and highly accurate temperature control, Powerstar Pneumatic Room Thermostats are designed to control heating and/or cooling by operating a variety of pneumatic
More informationHeat Link. Technical Guide
Heat Link Stat Link Technical Guide Third Version, May 2011 1 Table of Contents Thermostatic Zones Defined...................................... 4 StatLink System Components.....................................
More informationT4398A,B Precision Electric Heating Thermostat
T398A,B Precision Electric Heating Thermostat FEATURES PRODUCT DATA APPLICATION The T398 Electric Heating Thermostat provides precise, accurate line voltage control of electric heating equipment. A snap
More informationTHERMOSTAT i-basic 3 USER MANUAL Rev.100
USER MANUAL Thank you for trusting the Hitecsa Products. Our company has been offering the market an extended range of specialized units for air conditioning and cooling installations for over 35 years.
More informationW43A Humidistat. Features and Benefits
Master Catalog 125 Humidity Controls Section W Product/Technical Bulletin W43A Issue Date 1095 W43A The W43A controls humidifying and/or dehumidifying equipment. Typical uses include the control of humidity
More informationT170 Thermostat. Installation and Maintenance Manual. 24 VAC/ VAC 3-Speed Fan Control (Continuous or Cycling) or Staged Fan Control
Installation and Maintenance Manual IM-846 Group: Fan Coil Part Number: IM 846 Date: July 2006 T170 Thermostat 24 VAC/120 277 VAC 3-Speed Fan Control (Continuous or Cycling) or Staged Fan Control US 2006
More information! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION
Series 61 Low Water Cut-Off Typical Applications: - Primary or secondary low water cut-off for hot water and steam boilers. - Low water cut-off - High water cut-off - Alarm actuator OPERATION Maximum Boiler
More informationDescription Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)
INDEX UNIVERSAL ELECTRONIC CONTACTOR UPGRADE SURESWITCH 79 Description Model(s) Page(s) SureSwitch... 49P11-843... 79 CONTACTORS 80 82 Description Model(s) Page(s) 1 Pole... 94-388 Thru 94-395... 80 2
More informationwater source / fan coils
MANUAL BALL ALE W/MEMORY STOP (BMS) An adjustable stop position lever to limit travel of the On/Off handle. This allows the ball valve to be closed, and returned to the balance setting position without
More informationUNIT INFORMATION. Corp L7. Gauge Manifold Attachment... Page 30 Parts Arrangement... Page 8
SERVICE UNIT INFORMATION Corp. 9121 L7 CHA16 2 5 TON UNITS Litho U.S.A. CHA16 series units in the 2 5 ton sizes were introduced in the spring of 1990. The single package cooling units may be used in both
More informationVAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1
Model TRO24T4XYZ1 Description The TRO24T4XYZ1 is a combination controller and thermostat. The VAV Thermostat Controller is designed for simple and accurate control of any variable air volume box in a number
More informationGate Operator. Modfications
Gate Operator Modfications 100va Transformer G90 100 OP1 - Single Phase G90 100 OP3 -Three Phase Upgrades the transformer in the operator enclosure from 40va to 100va. Provides additional control circuit
More informationSingle Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual
We manage heat MANUAL Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239
More informationPipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual
MANUAL Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual Model FPT 130 Single Point Freeze Protection Heat Trace Control Table of Contents SCFP-CO-F130 Overview... 3 Installation...
More informationINDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153
INDEX GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 Model(s) Page(s) Flush Mount Fan/Limit/Attic Fan Control... 152 GAS DRYER VALVES 153 Model(s)
More informationULTRA-SAFE Explosion-proof Duct Heaters
Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer
More informationFluid Cooler Fan and Pump control panel
user manual Fluid Cooler Fan and Pump control panel INSTALLATION - OPERATION - MAINTENANCE Z02819_A M03-171B ISSUED 07/2014 0/2017 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR OR SERVICING THIS
More informationVariable Area Flowmeters Ratosight TM Flow Rate Indicators with Optional Ratolarm - 10A2235
Data Sheet (US) Variable Area Flowmeters Ratosight TM Flow Rate Indicators with Optional Ratolarm - 10A2235 Easily Cleaned - Disassembly is simplified by O-ring construction MODEL 10A2235A-OA Virtually
More informationTB-200 CD-TB PRODUCT OVERVIEW. Product. Description. Specifications SKU: TB-200. Wiring. Battery Powered Thermostat
CD-TB200-01 TB-200 Product Battery Powered Thermostat Description The Evolve Wireless Digital Thermostat/Temperature Sensor is designed to control the majority of HVAC systems when used in conjunction
More informationSERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS
SERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings.................................................................. 2 2. Accessibility Of Appliance....................................................
More informationFan Coil Thermostat Controller Specification and Installation Instructions. Model TFH24F3XYZ2 Stand-alone with Internal Humidity Sensor
Model TFH24FXYZ2 Stand-alone with Internal Humidity Sensor Description The TFH24FXYZ2 is a fully configurable controller designed specifically for 2 pipe and 4 pipe fan coil applications. No additional
More informationRefer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents
TABLE OF CONTENTS A complete line of commercial, industrial, and residential heating equipment is offered. This catalog describes in detail the gas-fired, gravity and power vented, commercial/ industrial
More informationB24 SERVICE UNIT INFORMATION B24 SERIES ADD-ON BLOWER ECB24 SERIES ELECTRIC HEAT
SERVICE UNIT INFORMATION Corp. 9311 L2 B24 Litho U.S.A. The B24 blower units are designed for multi-position installation with add-on C22FC/CR22/CH22 or C24FC/ CR24/CH24 series coil sections. The B24 may
More informationPowers Controls Low Temperature Detection Thermostat
Document No. 155-016P25 ET 134-22 Rev. 1, February, 2000 Powers Controls Low Temperature Detection Thermostat Description The electric Low Temperature Detection Cut-out and Alarm Thermostat is a remote
More informationTHERMOSTAT series TM10
MECHANICAL THERMOSTAT series TM10 For central (main) or zoned control of low voltage heating or cooling systems not requiring a thermostat with fan control. Available in 2 and 3 wire (heating or cooling
More informationTHERMOSTATS & CONTROLS
COMPATIBILITY CHART o Compatible - See Model Selection Chart / Contact MEP ELECTRONIC W/ DIGITAL DISPLAY MECHANICAL - MANUAL TEMPERATURE CONTROL COMMERCIAL/ INDUSTRIAL LOW VOLT 6 2500 1 QMKS 1 HBB CBD
More informationTC-9102 Applications
Application Note January 7, 2004 APPLICATION NOTE TC-9102 Applications Configuring TC-9102 Applications...3 Introduction... 3 Key Concepts... 4 TC-9102 Controller... 4 Control Modes...8 Procedure Overview...
More informationTEC Controller Unit Conditioner - Two-Pipe Fan Coil Cooling or Heating, Application Application Note Building Technologies
TEC Controller Unit Conditioner - Two-Pipe Fan Coil Cooling or Heating, Application 2050 Application Note 140-1136 Building Technologies Table of Contents Overview... 4 Hardware Inputs... 5 Hardware Outputs...
More informationLOW VOLTAGE CONTROL CIRCUIT WIRING
INSTALLATION INSTRUCTIONS LOW VOLTAGE CONTROL CIRCUIT WIRING MODELS W**A W**L W**A*D W**L*D Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead just as planned. Manual : 2100-507A
More informationFAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design
FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design Fan motor (PSC or ECM). UL Listed 1 insulation conforms to UL Test 181 and NFPA 90A. Plenum air filter rack. (Filter Optional) Casing has
More informationMODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL
TRACON MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TABLE OF CONTENTS FPT 130 Overview... 2 Installation... 3 Power Source and Load Connections... 4 Temperature Sensor... 5 External
More informationAIR-COOLED CONDENSING UNIT UNITS PRODUCED AFTER JANUARY, 1996 INDEX SCHEMATIC DIAGRAM FIG. NO.
wiring diagrams AIR-COOLED CONDENSING UNIT 566D Sizes 120-240 Cancels: New WD 566D.120.1 11/15/96 UNITS PRODUCED AFTER JANUARY, 1996 INDEX UNIT 566D 120-240 ELECTRICAL CHARACTERISTICS (V-Ph-Hz) SCHEMATIC
More informationSERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -
SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN VC3ED ML-137013 - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly
More informationCedarbrook Sauna + Steam Family owned and operated since 1971
Cedarbrook Sauna + Steam Family owned and operated since 1971 We build cedar saunas, kits, sauna doors, accessories for commercial saunas & residential sauna rooms AND we have the expertise to fit you
More informationInstallation Manual for Hot Yoga Studio Electric Radiant Heating Version 3.0
Comfort System HG-122 Universal Thermostat Installation Manual for Hot Yoga Studio Electric Radiant Heating Version 3.0 More Ah ha! Less Uhhh? For easy to follow programming instructions visit: www.heatinggreen.com/thermostatinstructions-wiring-diagrams/
More informationTable of Contents. Protective Relays
Table of Contents KILOVAC WD Series, DIN Rail or Screw Mounted Introduction..........................................................11-2 KILOVAC WD25 Paralleling Relays........................................11-3
More informationAquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08
16/05/08 Aquatrol Indoor/Outdoor Control B3 Adjustable settings for boiler maximum temperature, boiler minimum temperature and outdoor low (design) temperature Selectable Warm Weather Shut Down (WWSD)
More informationSINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS INDEX. VOLTAGE (3 Ph, 60 Hz) ACCESSORIES
wiring diagrams SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS Cancels: New 542J Sizes 150, 180 12-1/2 and 15 Tons WD 542J.150.1 7/15/96 UNIT 542J 150 180 LABEL DIAGRAM TYPE Component Arrangement Schematic Component
More informationT8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase
M3375 M3375 T890A/908AJ Heating or Cooling Thermostat/Wallplate; T890A/Q68B Heating/Cooling Thermostat/Subbase Installation Instructions for the Trained Service Technician. Preparation NOTE: Order Q68B
More informationInstallation Manual for Hot Yoga Studio Electric Radiant Heating
105 Comfort System HG-122 Universal Thermostat Installation Manual for Hot Yoga Studio Electric Radiant Heating Version 3.0 More Ah ha! Less Uhhh? For easy to follow programming instructions visit: www.heatinggreen.com/thermostatinstructions-wiring-diagrams/
More informationUSER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION
MODEL 5100 USER MANUAL Compatible with low voltage multi-stage heat/cool systems with up to two stages of heating and two stages of cooling. READ ALL INSTRUCTIONS BEFORE PROCEEDING 1 2 3 4 5 6 7 CONTENTS
More informationInstallation in Standard & Variable Speed Indoor Air Handlers IMPORTANT
H6HK Series Electric Heater Kit INSTALLATION INSTRUCTIONS Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT These instructions are primarily intended to assist qualified individuals
More informationPowers Controls Free Energy Band TH 193 HC Hesitation Room Thermostat
Document No. 155-069P25 TH 193-5 Powers Controls Free Energy Band TH 193 HC Hesitation Room Thermostat 50 60 70 80 TH0356R1 70 60 80 POWERS Description Features The TH 193 HC Hesitation Thermostats are
More information45 Commerce Ave., Unit #2 South Burlington, VT tel: fax:
SMAT ZONE TM VAV Electronic Diffusers SMAT ZONETM www.smartdiffuser.com SMAT ZONE SE-HC/M, Type LT, Lay-in, T-Bar, VAV Fully Modulating Diffuser Specifications APPLICATION: The Model SE-HC/M VAV Smart
More informationB SERIES ELECTRIC FURNACE
MISSISSAUGA, ONTARIO L5T 1H9 TEL.: 905-670-2500 FAX: 905-795-8311 CUSTOMER SERVICE TEL.: 1-888-882-7626 B SERIES ELECTRIC FURNACE! WARNING 1. The user MUST contact a specialized contractor when a failure
More informationINTRODUCTION / TABLE OF CONTENTS
1 2 INTRODUCTION / TABLE OF CONTENTS Step One The LVCN 20 and LVCN 100 Series are general purpose level controllers offered in two configurations for pump and valve control. The LVCN 100 Series features
More informationMS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack
Product/Technical MS4PMUHVT Issue Date 09/30/02 MS4PMUHVT Multi-Stage Electronic Control with Relay Pack The MS4PMUHVT Multi-Stage Electronic Control is intended for multi-stage temperature control applications.
More informationUSER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat
WARNING! Important Safety Information Builder MODEL 2200 Series 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat USER MANUAL Compatible with low voltage multi stage heat/cool
More informationTM Series. Induced Draft, Counter Flow Optional Accessories
ANTIFREEZE PACKAGE / RESISTANCE HEATING OPTION The antifreeze package is supplied to provide protection against freezing of standing water in the cooling tower sump due to shutdown during winter operation.
More informationJDB4000AWB JDB4000AWQ JDB4000AWS JDB4000AWW MDB5600AWB MDB5600AWQ MDB5600AWS MDB5600AWW
Technical Information- Dishwasher JDB4000AWB JDB4000AWQ JDB4000AWS JDB4000AWW MDB5600AWB MDB5600AWQ MDB5600AWS MDB5600AWW Due to possibility of personal injury or property damage, always contact an authorized
More informationMICRO GROW GREENHOUSE SYSTEMS, INC ZEVO DR., SUITE B-1, TEMECULA, CA PHONE (951) FAX (951) Growmate Growmate Plus
MICRO GROW GREENHOUSE SYSTEMS, INC 42065 ZEVO DR., SUITE B-1, TEMECULA, CA 92590 PHONE (951)-296-3340 FAX (951)-296-3350 Growmate Growmate Plus INSTALLATION PROCEDURES GROWMASTER AND GROWMATE SERIES OF
More informationULTRA-SAFE Explosion-proof Duct Heaters
Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer
More informationPART NO. COMBUSTION AIR CAP
ACCESSORIES FOR SPACE-RAY TUBE HEATERS VENT CAP --- Sidewall or Roof Unique design prevents back drafts and assists in drawing off and exhausting the products of combustion regardless of wind direction
More informationTitle: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards
Date Description of Change Pages / Sections Modified ID 6/15/16 Entire document - mgl44 PART 1 - INTRODUCTION 1.1 PURPOSE A. This section is intended to define the general installation and minimum product
More informationTechnical Information- Dishwasher MDB8750AWB MDB8750AWQ MDB8750AWS MDB8750AWW MDB9750AWB MDB9750AWQ MDB9750AWS MDB9750AWW
Technical Information- Dishwasher MDB8750AWB MDB8750AWQ MDB8750AWS MDB8750AWW MDB9750AWB MDB9750AWQ MDB9750AWS MDB9750AWW Due to possibility of personal injury or property damage, always contact an authorized
More information! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-315(C)
Models 51, 51-S and 53 Boiler Water Feeders Models 51-2, 51-S-2 and 53-2 Feeder Cut-Off Combinations McDonnell & Miller Installation & Maintenance Instructions MM-315(C) OPERATION Maximum Water Supply
More informationSystem 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules
System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage s FANs 930, 125 Product/Technical Bulletin S350 Issue Date 0300 The S350A, S351A, and S352A Stage s are intended to be used with System
More informationElectric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features
Electric Pumps Introduction W4100, W4200 & W4300 Condensate Pumps Watson McDaniel s Condensate Return and Boiler Feed Pumps are equipped with Cast Iron bodies and Bronze Impellers. The pump receiver tanks
More informationCAUTION. No-Load Performance, Controls in Normal Position
Side-by-Side Refrigerator Technical Information JCD2292KT* JCD2292KT*2, JCD2295KE* JCD2295KE*2, JCD2297KE* JCD2297KE*2, JSD2695KES JSD2695KES2, JSD2695KG* JSD2695KG*0, JSD2697KE* JSD2697KE*2, MSD2660KEG*
More informationCommercial and Light Industrial Fire Alarm Control Panel
FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel Features Easily expandable. All new plug-in board design Two supervised audible circuits Lamp and system trouble circuit test Ground
More informationCAUTION. To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing. MDBTT50AW*
Dishwasher Technical Information ADB/CDB1500AW*, ADB2500AW*, CDU650AW*, DDB1501AW*, PDBL390AW*, MDBH945AW*, MDBH955AW*, MDBH965AW*, MDBM601AW*, MDBS561AW*, MDBTT50AW*, MDBTT60AW*, MDBTT70AW*, MDB4651AW*,
More informationEG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G
E SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF DATE: 11/13/06 2/1/07 1 Copyright, E, Inc. E 1. ENERAL...4 1.1 Scope Of Work... 4 1.2 Codes and Standards... 4 2. PRODUCTS...5
More informationJBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0
Bottom Mount Refrigerator Technical Information JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0 Due to a possibility
More information100A / 200A. Maximum Heating Load: Enclosure Type: NEMA 4
Contactor Panel with GFEP Data Sheet GENERAL PRODUCT INFORMATION Simplify your snowmelt installation with ProLine Radiant contactor panels with built in GFEP. These rugged panels feature built-in ground
More informationTEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers Catalog Page
Code. LIT-1900896 Issued February 17, 2017 TEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers Catalog Page Description The TEC3000 Series Thermostat
More informationT60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability
T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability Product Bulletin T601DFH-4, T602DFH-4, T603DFH-4, T604DFH-4, T605DFH-4, T601DFH-4+PIR, T602DFH-4+PIR,
More informationINSTALLATION INSTRUCTIONS MASTER CONTROLLERS MC91AE MC92AE MC93AE MC94AE MC94AEH MC96AEH
INSTALLATION INSTRUCTIONS MASTER CONTROLLERS MODELS: MC91AE MC92AE MC93AE MC94AE MC94AEH MC96AEH Bard Manufacturing Company Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. Manual: 2100-189I
More informationCRYOGENIC EXPERTS, INC. World Wide Web Toll Free FOR CEXI Phone (805) Facsimile (805)
CRYOGENIC EXPERTS, INC. World Wide Web http://www.cexi.com E-mail cexi@cexi.com Toll Free 1-800-FOR CEXI Phone (805) 520-8631 Facsimile (805) 520-8640 I. Installation Instructions CEXI ELECTRIC VAPORIZER
More information! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing.
Dishwasher Technical Information JDB1080AW*, JDB1090AW*, JDB1270AW*, JDB2100AW*, MDB9750AW*, NDB8630AW*, RJDW2480B*, RJDW2481B*, DB5710D* Due to possibility of personal injury or property damage, always
More informationEC Series Wall Unit Humidifier
Read and Save These Instructions EC Series Wall Unit Humidifier Controller Operation Manual SEASONAL DRAIN SAFETY CIRCUIT OPEN POWER FILL VALVE OPEN WATER LEVEL FULL COOL DOWN CYCLE DRAIN VALVE OPEN HEATER
More informationFLT93 Installation, Operation and Troubleshooting Guide
FLT93 Installation, Operation and Troubleshooting Guide Pre-Installation A. To get the best results from the instrument, the instrument should be mounted 20 pipe diameters downstream from any valve, pipe
More informationPOWERS Pneumatic Thermostat Covers
Technical Instructions Document No. A6V11225047 Pneumatic Thermostat s 192-2xx Plastic 192-2xxW Plastic 192-3xx 856-0xx D Series Description Proven to provide fast response and highly accurate temperature
More informationSmartZone TM System Manual
SmartZone TM System Manual Rev C3 June 1, 2007 Page 0 of 21 Table of Contents SmartZone TM System Manual Rev C3. April 23, 2007 Introduction..2 o Why Use Residential Zoning?..2 Architectural Challenges...
More informationFireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel
PROTECTOWIRE FireSystems Features Easily expandable Two supervised audible circuits Lamp and system trouble circuit test Ground fault detection Initiating device circuit (IDC) alarm test Monitors up to
More informationTechnical Manual. VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater. Provided by: Chart Inc.
Technical Manual VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater Provided by: Chart Inc. 407 7th Street NW New Prague, MN 56071 USA (800) 400-4683 Part Number 20977233 Rev. A 2016 Chart Inc.
More informationDue to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.
Bottom Mount Refrigerator Technical Information Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.! CAUTION
More informationEmerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING
Emerson Inspire 1HDEZ-1521 Installation Instructions Thermostat/Interface Equipment Control TROUBLESHOOTING FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL
More informationTEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs
TEC2620 Series Non-Programmable Fan Coil Network Thermostat ler and Remote I/O Relay Packs TEC2620H-0, TEC2620C-0, TEC2620H-0+PIR, TEC2620C-0+PIR, TEC2621H-0, TEC2621C-0, TEC2621H-0+PIR, TEC2621C-0+PIR
More informationESSEX ENGINEERING CORPORATION
WATER/WASTEWATER TREATMENT CONTROL SYSTEMS AND SUBSYSTEMS 2000 SERIES CONTROL SYSTEMS: 2000 series are for surface mounting inside a control cabinet Model 2024 Electronic Alternator Duplex (two pump) pump
More informationDual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual
We manage heat MANUAL Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239
More information