Do not provide service loops or leave excess wire in J-box. Cut all wire lengths to size sufficient to reach termination without stress or excess.
|
|
- Gary McKenzie
- 6 years ago
- Views:
Transcription
1 .... Safety Procedures WRNING Dangerous environment. Highly flammable/explosive fuels and high voltage are present. Failure to observe all safety precautions could result in serious injury or death. Observe all safety precautions as outlined in Gasboy manuals. Installation Procedures Install a single EMERGEY POWER CUTOFF control to remove C power from site dispensing equipment. (The control is an additional safety feature, and not a substitute for National Electrical Code (NEC )/National Fire Protection ssociation (NFP) 0 circuit breaker requirements). Label the EMERGEY POWER CUTOFF switch and instruct owner to keep area clear of obstacles. IMPTNT INFMTION Devices such as Distribution Boxes (D-Boxes), two-wire, and so on must be de-energized or have wiring disconnected from the dispenser by the Emergency Stop or equivalent mechanism. Third-party devices such as those supplying power or any form of communication to a dispenser (intercoms, third-party controllers and such) must also be de-energized or the wiring supplying that power be disconnected when activating the Emergency Power Cutoff control or equivalent mechanism. Provision to accommodate this must not introduce noise [Radio Frequency Identifier(RFI) or electrical)]into sensitive pump dispenser electronic field wiring circuits during normal pump/dispenser operation. De-energizing of the external equipment through the emergency stop or equivalent device is recommended. Connect an insulated grounding conductor from the dispenser power panel to the site grounding electrode (size per NEC). Install power breakers to each circuit leading to the dispensing unit and Submersible Turbine Pump (STP). It must be capable of simultaneously disconnecting hot and neutral conductors. Note: In Canada switching neutral is contrary to the Canadian Electrical Code (CEC), reference part, rule -0. Only field wiring connections are shown in the Junction boxes (J-boxes). Cap all unused wires. Local and National Electrical Codes may apply. Install conduit per NEC for hazardous locations. Potting is required for conduit that passes through any portion of a hazardous vapor area to ensure vapor barrier integrity. Wires - ll wires are WG (copper stranded) unless otherwise noted. Dispenser ground - wire is WG (copper stranded). Power loading and distance run may require larger wire size. Wire all circuits NEC Class, except wiring to speaker (intercom) and call button which must be NEC Class. Gasboy Two-wire is NEC Class and may share the main power conduit Do not provide service loops or leave excess wire in J-box. Cut all wire lengths to size sufficient to reach termination without stress or excess. Valve is optional on Mechanical and Commercial pumps - Grade, Hose or Grade, Hose. On commercial units in an international installation (0 VC single phase), valves must be rated at 0 VC. Wires labeled with a prefix of signify Side /Front and a prefix of B signify Side /Rear. Side is the J-box opening side. The second pump motor is used only with dual product or 90K. Wires labeled with two colors signify that the first color is the color of the wire and the second is that of the stripe. For example, / would indicate a blue wire with a white stripe. Internal wiring that is not field terminated may be white in color. STP isolation relay boxes are required by NEC - to: a. llow service of one unit safely without removing power from all dispensing equipment. b. Prevent damage to equipment from cross-phasing. Damage caused by cross-phasing is not covered by warranty. (Use local supplier for Isolation Relay Boxes). To determine which mode of satellite operation is relevant for your application, refer to the Weights and Measures (W&M) Handbook. In many cases, the satellite must be wired so it cannot dispense product while the master remote dispenser is dispensing and vice versa. Use the correct wiring diagram according to your application. The input line UTH (CONTROL/SUBM FEED) is comprised of two wires which are tied together at the factory. To avoid damage to the CPU PC board, all unused wires must be individually capped, and before applying power, you must verify that the RESET COMPLETE, FST FLOW, STP OUT wires are not shorted to conduit or chassis. STP OUT line can supply 00 m C maximum to control submersible starter relays. This line must not be directly connected to a submersible pump. RESET COMPLETE (switch detect) line can supply 0 m C maximum for connecting to fuel management system circuitry and in applications where control of a remote slow flow valve (satellite) is required. FST FLOW line can supply 0 m C maximum is provided to allow for control of a satellite along with remote control or monitoring of the fast flow valve found in the pump. If the UTH (CONTROL/ FEED) line is controlled by a fuel management system using solid state relays, a resistor assembly must be installed between the Control Feed line and Feed Neutral to prevent false triggering of the authorization input. The resistor assembly is.k OHM, 0 Watt (P/N C0) for /0 VC domestic and 0K OHM, 0 Watt (P/N C0) for 0 VC international wiring. When used with an aboveground tank, the valve mounted at the tank MUST NOT be connected to the RESET COMPLETE or STP OUT lines. If the optional internal relay kit is installed ND the valve s current draw will not exceed mp, the valve can be connected to the EXTERNL VLVE line. Otherwise, it should be driven from the external submersible starter relay. In all cases, the tank valve must operate at the same voltage as the pump motor. If combining a remote dispenser with a fuel management system, the maximum HP limitation for directly driving a remote dispenser without the use of an additional relay of submersible starter must be the lower of the two components. For Retail electronic units, DC conduit is used only in Pulse-out units. For Optional TopKT PLUS Only Electrical Rating Pump Motor VC 0 0 VC 0 Hz. Lights 0 VC 0/0 Hz. 0 VC 0/0 Hz. Reference Manuals Control Valves VC 0 VC Electric Reset 0 VC MDE- tlas Fuel Systems Installation Manual MDE- tlas Fuel Systems Site Preparation Manual Note: Voltages mentioned below refer to motor voltages only. Contents Sheet Description Models Cover Sheet (Safety, Installation Procedures, Electrical Rating and References) Retail Electronic, Dual Pump Motors, Pulse-out, 0/0 VC K/K, KTWM, KTW/KTW, KTW 9 0 Commercial Electronic, Dual Pump Motors, Single Phase /0 VC Commercial Electronic, Dual Pump Motors, -phase 0 VC Commercial Electronic, Dual Pump Motors, -phase 0 VC Commercial Mechanical, Dual Pump Motors, /0 VC Retail Electronic, Dual Pump Motors, Pulse-out, -phase 0 VC Commercial Mechanical, Single Pump Motor, -phase 0 VC Retail Electronic, Dual Pump Motors, Pulse-out, -phase 0 VC Commercial Mechanical, Dual Pump Motors, -phase 0 VC Commercial Mechanical, Single Pump Motor, -phase 0 VC Commercial Electronic, Dual Pump Motors, 0 VC Commercial Mechanical, Dual Pump Motors, 0 VC Commercial Mechanical, Dual Pump Motors, -Phase 0 VC Commercial Electronic, Single Pump Motor, 0 VC 9K/9K, 9KTWM, 9KTW/9KTW, 9KTW 9K/9K, 9KTWM, 9KTW/9KTW, 9KTW 9K/9K, 9KTWM, 9KTW/9KTW, 9KTW, 90K 9K/9K, 9KTWM, 9KTW/9KTW, 9KTW K/K, KTWM, KTW/KTW, KTW K/K, KTWM, KTW/KTW, KTW 9K/9K, 9KTWM, 9KTW/9KTW, 9KTW K/K, KTWM, KTW/KTW, KTW K/K, KTWM, KTW/KTW, KTW 9K/9K, 9KTWM, 9KTW/9KTW, 9KTW K/K, KTWM, KTW/KTW, KTW 9K/9K, 9KTWM, 9KTW/9KTW 90K 90K 90K 90K. Two-Wire Communication Wiring: For installations with new wiring, use unshielded twisted pair (UTP) data wires. Wiring Spec: 0- twists per foot, WG up to 000 foot runs (000 ft. total) or WG up to 00 foot runs (00 ft. total) unshielded, 00 V minimum, stranded annealed copper tinned wire, PVC insulation of type TFFN, THHN or MTW, UL approved gasoline and oil resistant. Reference C&M Corporation Part # ( WG) or equivalent. Refer to Site Preparation Manual requirements where WG may be required.. Refer to MDE-0 TopKT PLUS Installation Manual. For T-G Varistor, the black wire is connected to the C hot and the white wire is connected to the C neutral. For T-G Varistor, the brown wire is connected to the C hot and the blue wire is connected to the C neutral.. 9. Consult manufacturer specifications for wire nuts to determine maximum number of wires that may be used per nut. For US 0 VC installations, wires labeled HOT are to be connected to L and wires labeled NEUTRL are to be connected to L. Used On tlas Pumps - Retail and Commercial Versions with Electronic or Mechanical Computers. Sheet of 0/ FE-N
2 RETIL ELECTRONIC UNIT MODELS: K/K, KTWM, JUTION BOX ELECTRONICS CBINET KTW/KTW, KTW. T VRIST. SSEMBLY -G -G /-G /-G NOTE: Pump handle goes to M09 and Pulser goes to M000. ERTH GROUND SP- -G(SPRE) SP- -G(SPRE) UTH UTH B SPRE SPRE J00 NOTE: J00 connects to P0 or P0 to match incoming UTH voltage (P0 is for 0 VC, P0 is for 0 VC). -G -G -G DT IN (+) DT OUT (-) LIGHT LIGHTS /0 VC. 0. B-SIDE VLVES WI SME S -SIDE G V G M0000 MIN -G SLOW DOWN VLVE -G MIN VLVE 0 -G -G STP -G -G B -G B -G B -G 9 -G 9 -G J0- J0- TC TC + CD MODULE /0 VC CD MODULE - NEUTRL JK PK/PK HOT G G FEED G G J0 STP B 9 MIN VLVE B SLOW DOWN VLVE B WIRE J0- J0- DT IN (+) DT OUT (-) J0 (To Pump Control Board) -G -G J0 P0 K. G G LED DRIVER (V 0V) -G -G. -NEUTRL -LINE L B-NEUTRL B-LINE L NOTE: Control System Setup. For Money, use Penny and Penny Return and for Volume, use Pulse and Pulse Return. PENNY RTN PENNY RTN PENNY RTN PENNY RTN NOTES: Dual sided unit shown. For single sided unit make Side connections and cap Side wiring. ll unused wiring must be properly capped.. On all 00K models, if Pulse-out mode is not being used, the UTH lines must remain open. -G -G -G -G -G -G -G -G PENNY RTN PENNY RTN PENNY RTN PENNY RTN G G G B V 0V B 0V G G Retail Electronic, Dual Pump Motors, Pulse-out, 0/0 VC. 9. G DC M0900 with yellow stripe HOT G FEED G M0900 J0 M0900 J0B JK PK/PK G G K M000 P0/B J0 M000 P0/B J0 No 0/ G G TO P0 RETIL OUT PC TO P0B RETIL OUT PC TO J Sheet of FE-N P
3 COMMERCIL ELECTRONIC UNIT MODELS: 9K/9K, 9KTWM, 9KTW/9KTW, 9KTW LOWER HOUSING P P DPTER MICRO LIGHTS /0 VC MIN FIELD RETURN. I/F OUT/SIDE OUT/SIDE B PUL RETURN PUL B RETURN B PUL RETURN PUL B RETURN. RESET COMPLETE To External Fuel Management System with RS- and RS- RS- LN/ WN 0 UTH UTH B RESET COMPLETE B B. DC FIELD / / T-GX VRIST SSEMBLY. DC WIRES NOTE: Do not make this connection in the field. This connection will be made at the factory, if required. MIN JUTION BOX NEUT - UTH - HOT FEED HOT FEED 0 UTH - B B B NEUT - B B DC MIN IR GP BRRIER CT- CT- CT- RJ- Receptacle Coupling To TopKT PLUS Hose C J0 Hose C I/F PUL I/F No with yellow stripe.. NOTE: Dual sided unit shown. For single sided unit make Side connections and cap Side wiring. ll unused wiring must be properly capped. Commercial Electronic, Dual Pump Motors, Single Phase /0 VC Sheet of 0/ FE-N
4 COMMERCIL ELECTRONIC UNIT MODELS: 9K/9K, 9KTWM, 9KTW/9KTW, 9KTW LOWER HOUSING L L L L L L L L L 0 VOLT CONTROL 0 VC -PHSE SIDE 0 VC -PHSE SIDE P P DPTER. MICRO L 0 VC THREE PHSE 0/0 HZ MIN FIELD RESET COMPLETE 0 UTH NEUT - UTH - HOT FEED HOT FEED 0 MIN Hose C LIGHTS /0 VC RETURN I/F OUT/SIDE OUT/SIDE B PUL RETURN PUL B RETURN B PUL RETURN PUL B RETURN To External Fuel Management System with RS- and RS- UTH B RESET COMPLETE B B.. RS- LN/ WN. DC FIELD / / T-GX VRIST. SSEMBLY DC WIRES MIN JUTION BOX UTH - B B B NEUT - B B DC CT- CT- CT- RJ- Receptacle Coupling IR GP BRRIER To TopKT PLUS J0 Hose C I/F PUL I/F No with yellow stripe. NOTE: Dual sided unit shown. For single sided unit make Side connections and cap Side wiring. ll unused wiring must be properly capped. Commercial Electronic, Dual Pump Motors, -phase 0 VC Sheet of 0/ FE-N
5 COMMERCIL ELECTRONIC UNIT L MODELS: 9K/9K, 9KTWM, 9KTW/9KTW, 9KTW, 90K LOWER HOUSING 0 VOLT CONTROL 0 VC -PHSE SIDE 0 VC -PHSE SIDE P P DPTER. MICRO L 0 VC THREE PHSE 0/0 HZ MIN FIELD RESET COMPLETE 0 UTH NEUT - UTH - HOT FEED HOT FEED 0 MIN Hose C LIGHTS /0 VC RETURN I/F OUT/SIDE OUT/SIDE. B PUL RETURN PUL B RETURN B PUL RETURN PUL B RETURN UTH B RESET COMPLETE B B To External Fuel Management System with RS- and RS- RS- LN/ WN.. DC FIELD / / T-GX VRIST SSEMBLY. DC WIRES MIN JUTION BOX UTH - B B B NEUT - B B NOTE: This valve is not present for 90K. DC IR GP BRRIER CT- CT- CT- RJ- Receptacle Coupling To TopKT PLUS J0 Hose C I/F PUL I/F Crimped No with yellow stripe. NOTE: Dual sided unit shown. For single sided unit make Side connections and cap Side wiring. ll unused wiring must be properly capped. Commercial Electronic, Dual Pump Motors, -phase 0 VC Sheet of 0/ FE-N
6 MECHNICL UNIT MODELS: 9K/9K, 9KTWM, 9KTW/9KTW, 9KTW K/K, KTWM, KTW/KTW, KTW SIDE SIDE LIGHTS /0 VC. MIN FIELD Main Junction Box SIDE SIDE WIRE MRKER IS WRPPED ROUND THE SIDE ONE (LEFT SIDE) F TWIN HOSE OUTLETS No + V POWER + V POWER JUTION BOX ELECTRONIC WIRING nd F nd HOSE OUTLET (TWIN ONLY) 00: 00: JUTION BOX REED WIRING / / nd F nd HOSE OUTLET (TWIN ONLY) 0: 0: with yellow stripe. NOTE: Dual sided unit shown. For single sided unit make Side connections and cap Side wiring. ll unused wiring must be properly capped. Commercial Mechanical, Dual Pump Motors, /0 VC Sheet of 0/ FE-N
7 RETIL ELECTRONIC UNIT MODELS: K/K, KTWM, KTW/KTW, KTW L 0 VOLT CONTROL 0 VOLT CONTROL. DT IN (+) DT OUT (-) LIGHT 0 VC THREE PHSE 0/0 HZ. LIGHTS /0 VC NOTE: Control System Setup. For Money, use Penny and Penny Return and for Volume, use Pulse and Pulse Return.. PENNY RTN PENNY RTN PENNY RTN PENNY RTN T VRIST. SSEMBLY JUTION BOX -G -G /-G /-G 0. -G -G -G 0 VC -PHSE SIDE 0 VC -PHSE SIDE -G -G -G -G -G -G -G -G B-SIDE VLVES WI SME S -SIDE PENNY RTN PENNY RTN PENNY RTN PENNY RTN DC M0900 MIN M0000 SP- -G(SPRE) SP- -G(SPRE) UTH UTH B -G -G 0 -G -G -G -G B -G B -G B -G 9 -G 9 -G WIRE CD MODULE /0 VC CD MODULE-NEUTRL STP B 9 J0- J0- J0- J0- TC TC + J0 HOT G FEED G HOT G FEED G. M0900 M0900 ELECTRONICS CBINET NOTE: Pump handle goes to M09 and Pulser goes to M000. SLOW DOWN VLVE MIN VLVE STP MIN VLVE B SLOW DOWN VLVE B JK JK J0 J0B SPRE SPRE P0 DT IN (+) DT OUT (-) J0 M000 P0/B J0 M000 P0/B J0 J00. J0 (To Pump Control Board) -G -G NOTE: J00 connects to P0 or P0 to match incoming UTH voltage (P0 is for 0 VC, P0 is for 0 VC). LED DRIVER (V 0V) -G -G TO P0 RETIL OUT PC TO P0B RETIL OUT PC No with yellow stripe. NOTES: Dual sided unit shown. For single sided unit make Side connections and cap Side wiring. ll unused wiring must be properly capped.. On all 00K models, if Pulse-out mode is not being used, the UTH lines must remain open. Retail Electronic, Dual Pump Motors, Pulse-out, -phase 0 VC Sheet of 0/ FE-N
8 MECHNICL UNIT L MODELS: 9K/9K, 9KTWM, 9KTW/9KTW, 9KTW K/K, KTWM, KTW/KTW, KTW 0 VOLT CONTROL 0 VC -PHSE SIDE SIDE MIN JUTION BOX. 0 VC THREE PHSE 0/0 HZ NEUTRL SWITCH SCREW TERMINL SIDE SIDE LIGHTS /0 VC MIN FIELD 0 VC -PHSE SIDE 0 VOLT CONTROL SWITCH SIDE PHSE FEED () WIRE MRKER IS WRPPED ROUND THE SIDE ONE (LEFT SIDE) F TWIN HOSE OUTLETS No. + V POWER + V POWER JUTION BOX ELECTRONIC WIRING nd F nd HOSE OUTLET (TWIN ONLY) 00: 00: JUTION BOX REED WIRING / / nd F nd HOSE OUTLET (TWIN ONLY) 0: 0: with yellow stripe. NOTE: Dual sided unit shown. For single sided unit make Side connections and cap Side wiring. ll unused wiring must be properly capped. Commercial Mechanical, Single Pump Motor, -phase 0 VC Sheet of 0/ FE-N
9 RETIL ELECTRONIC UNIT L MODELS: K/K, KTWM, KTW/KTW, KTW L L L L L L 0 VOLT CONTROL 0 VOLT CONTROL 0 VC -PHSE SIDE 0 VC -PHSE SIDE. DT IN (+) DT OUT (-) LIGHT 0 VC THREE PHSE 0/0 HZ. LIGHTS /0 VC. T VRIST. SSEMBLY JUTION BOX -G -G /-G /-G -G -G -G 0. B-SIDE VLVES WI SME S -SIDE M0000 MIN SP- -G(SPRE) SP- -G(SPRE) UTH UTH B -G -G 0 -G -G -G -G B -G B -G B -G 9 -G 9 -G J0- J0- TC TC + HOT G FEED G SLOW DOWN VLVE MIN VLVE STP ELECTRONICS CBINET NOTE: Pump handle goes to M09 and Pulser goes to M000. WIRE CD MODULE /0 VC CD MODULE-NEUTRL STP B MIN VLVE B SLOW DOWN VLVE B JK 9 J0- J0- SPRE SPRE J0 DT IN (+) DT OUT (-) J0 J00 -G -G P0. NOTE: J00 connects to P0 or P0 to match incoming UTH voltage (P0 is for 0 VC, P0 is for 0 VC). J0 (To Pump Control Board) LED DRIVER -G -G No NOTE: Control System Setup. For Money, use Penny and Penny Return and for Volume, use Pulse and Pulse Return. PENNY RTN PENNY RTN PENNY RTN PENNY RTN -G -G -G -G -G -G -G -G PENNY RTN PENNY RTN PENNY RTN PENNY RTN DC M0900 HOT G FEED G. M0900 M0900 JK J0 J0B M000 P0/B J0 M000 P0/B J0 TO P0 RETIL OUT PC TO P0B RETIL OUT PC with yellow stripe. NOTES: Dual sided unit shown. For single sided unit make Side connections and cap Side wiring. ll unused wiring must be properly capped.. On all 00K models, if Pulse-out mode is not being used, the UTH lines must remain open. Retail Electronic, Dual Pump Motors, Pulse-out, -phase 0 VC Sheet 9 of 0/ FE-N
10 MECHNICL UNIT L L L MODELS: 9K/9K, 9KTWM, 9KTW/9KTW, 9KTW K/K, KTWM, KTW/KTW, KTW L L L L L L. 0 VC -PHSE SIDE 0 VOLT CONTROL MIN JUTION BOX SIDE. 0 VC THREE PHSE 0/0 HZ SWITCH GROUND SCREW SIDE MIN FIELD LIGHTS /0 VC 0 VC -PHSE SIDE 0 VOLT CONTROL SIDE SWITCH SIDE WIRE MRKER IS WRPPED ROUND THE SIDE ONE (LEFT SIDE) F TWIN HOSE OUTLETS JUTION BOX ELECTRONIC WIRING JUTION BOX REED WIRING. NOTE: Dual sided unit shown. For single sided unit make Side connections and cap Side wiring. ll unused wiring must be properly capped. Commercial Mechanical, Dual Pump Motors, -phase 0 VC + V POWER + V POWER nd F nd HOSE OUTLET (TWIN ONLY) No 00: 00: with yellow stripe 0/ / / 0: 0: nd F nd HOSE OUTLET (TWIN ONLY) Sheet 0 of FE-N
11 MECHNICL UNIT MODEL: 9K/9K, 9KTWM, 9KTW/9KTW L 0 VC -PHSE SIDE 0 VOLT CONTROL MIN JUTION BOX SIDE. 0 VC THREE PHSE 0/0 HZ NEUTRL SWITCH GROUND SCREW SIDE SIDE LIGHTS /0 VC MIN FIELD 0 VC -PHSE SIDE 0 VOLT CONTROL SWITCH SIDE No. + V POWER + V POWER JUTION BOX ELECTRONIC WIRING nd F nd HOSE OUTLET (TWIN ONLY) WIRE MRKER IS WRPPED ROUND THE SIDE ONE (LEFT SIDE) F TWIN HOSE OUTLETS 00: 00: JUTION BOX REED WIRING / / 0: 0: nd F nd HOSE OUTLET (TWIN ONLY) with yellow stripe. NOTE: Dual sided unit shown. For single sided unit make Side connections and cap Side wiring. ll unused wiring must be properly capped. Commercial Mechanical, Single Pump Motor, -phase 0 VC Sheet of 0/ FE-N
12 COMMERCIL ELECTRONIC UNIT MODEL: 90K LOWER HOUSING 9 0 VC 0 VC P. P DPTER RESET COMPLETE NEUT -. MICRO LIGHTS /0 VC RETURN I/F MIN FIELD OUT/SIDE OUT/SIDE B PUL RETURN PUL B RETURN To External Fuel Management System with RS- and RS- RS- 0 UTH NOTE: Pump motors must be wired as 0 VC to reduce current draw. LN/ WN. B B UTH B RESET COMPLETE. DC FIELD CT- RJ- Receptacle Coupling MIN JUTION BOX / / NOTE: Do not make this connection in the field. This connection will be made at the factory, if required. T-GX VRIST SSEMBLY. Commercial Electronic, Dual Pump Motors, 0 VC DC WIRES No UTH - HOT FEED HOT FEED 0 UTH - B B B NEUT - B B DC MIN with yellow stripe IR GP BRRIER CT- To TopKT PLUS Sheet of 0/ FE-N Hose C J0 Hose C I/F PUL I/F
13 MECHNICL UNIT MODEL: 90K 9. 0 T. SIDE LIGHTS /0 VC MIN FIELD LIGHT FEED LIGHT RETURN MIN JUTION BOX WIRE MRKER IS WRPPED ROUND THE SIDE ONE (LEFT SIDE) F TWIN HOSE OUTLETS JUTION BOX ELECTRONIC WIRING JUTION BOX REED WIRING + V POWER 00: / 0:. NOTE: Pump motors must be wired as 0 VC to reduce current draw. Commercial Mechanical, Dual Pump Motors, 0 VC Crimped No with yellow stripe Sheet of 0/ FE-N
14 MECHNICL UNIT MODEL: 90K SIDE 9. 0 VC 0 VC -PHSE -PHSE SIDE. SIDE LIGHTS /0 VC MIN FIELD LIGHT FEED LIGHT RETURN MIN JUTION BOX WIRE MRKER IS WRPPED ROUND THE SIDE ONE (LEFT SIDE) F TWIN HOSE OUTLETS JUTION BOX ELECTRONIC WIRING JUTION BOX REED WIRING + V POWER 00: / 0:. Commercial Mechanical, Dual Pump Motors, -Phase 0 VC Crimped No with yellow stripe Sheet of 0/ FE-N
15 COMMERCIL ELECTRONIC UNIT MODEL: 90K GND L N L SIDE 9.. LOWER HOUSING MICRO. LIGHTS LIGHTS /0 VC FIELD WIRING. I/F OUT/SIDE OUT/SIDE To External Fuel Management System with RS- and RS- RS- DC FIELD / / T-GX VRIST SSEMBLY. RETURN B PUL RETURN PUL B RETURN LN/ WN CT- RJ- Receptacle Coupling U CT- To TopKT PLUS I/F. SYSTEM ERTH GROUND EMERGEY POWER CUTOFF GND L N L /0 VC SINGLE PHSE 0/0 HZ NOTE: Pump motors must be wired as 0 VC to reduce current draw.. Commercial Electronic, Single Pump Motor, 0 VC Crimped No with yellow stripe Sheet of 0/ FE-N
Required Tools The following tools are required for the installation of the kit: Open-end Wrench Set Flat-tip Screwdriver Cross-tip Screwdriver
MDE-4511B Card System Interface and Electro-mechanical Totalizer Retrofit Kits for Atlas Commercial Electronic Units Installation Instructions June 2011 Introduction Purpose This document provides installation
More informationInstallation Instructions
50ZPB, C, 50ZHB, C, PA3Z ---A, PH3Z ---A, PA4Z, PH4Z, PAJ4,PHJ4,WJA4,WJH4 SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters 5---20 kw For 14 SEER, R---410A Manufactured Home Installation Instructions
More informationInstallation Instructions
EHNA Electric Heaters 5-20kW For 60 Hz Small Packaged Products MODELS: PAD3, PHD3, PAD4, PHD4, PAD5, PHD5, WPA3, WPH3 Installation Instructions NOTE: Read the entire instruction manual before starting
More informationInstallation Instructions
Electric Heaters 5 --- 20 kw SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters For 13 SEER, R---410A Manufactured Home Installation Instructions NOTE: The Dual Point Kit can only be installed on
More informationInstallation Instructions
50ES--A, 50EZ--A, 50VG--A, B, 50VL--A, B, 50VR--A, 50VT--A, B 604D-- --A, 607C-- --A, B, 607E-- --A, 704D-- --A, 707C-- --A, B, 707E-- --A PA3G -- -- A, PH3G -- -- A, PA4G, PH4G PAD3, PHD3, PAD4, PHD4,
More informationABH BASIN HEATER CONTROLS PACKAGE. engineering data and specifications
BH BSIN HETER CONTROLS PCKGE engineering data and specifications BH Basin Heater Control Package 2 BH DVNCED BSIN HETER CONTROLS The Marley BH basin heater package controls the ON and OFF operation of
More informationCOMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods
1. BASIC ELECTRICAL MATERIALS 1. All conduit and raceway must be 3/4" or larger. Exposed raceway in finished areas shall be in 700 or larger wiremold. Exception: runs to individual devices 10 or less,
More informationInstallation Instructions
50ES---A, 50EZ---A, 50VL---A, 50VG---A, 50VR---A, 50VT---A, 604D--- ---A, 607C--- ---A, 607E,--- ---A, 704D--- ---A, 707C--- ---A, 707E--- ---A PA3G --- --- A, PH3G --- --- A SMALL PACKAGED PRODUCTS Electric
More informationEMS510 Electrical Wiring Guide Volume 2, Rev 1.4
EMS510 Electrical Wiring Guide Volume 2, Rev 1.4 Prepared by Michael L. Kominske Environmental Monitor Service Inc. PO Box 4340 Yalesville, CT 06492 Phone 203.935.0102 Fax 203.634.6663 Email: sales@emsct.com
More informationMASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc
MASTER JOCKEY PUMP CONTROLLER Model JPCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page 4 Model
More informationRELEASE DEVICE CONTROLS
RELEASE DEVICE CONTROLS RELEASE DEVICE MODEL C+ INSTALLATION MANUAL UL LISTED CANADIAN LISTED CSFM: 7300-48:00 GENERAL DESCRIPTION: MADE IN THE U.S.A. S/N: The LM0-C+ Release Device/Control Panel is a
More informationCimco Series 21. Series 21 - Specifications INDEX. Description. Operational Specification 2
Series 21 - Specifications INDEX Description Page Operational Specification 2 Analog Operational Specification - Communications Options 3 Digital Operational Specification - Communications Options 4 Hardware
More informationPublic Safety DAS Annunciator Panel
Public Safety DAS Annunciator Panel 120 VAC Models: 1221-A, 1221-B, 1221-C Revision D 91117 48 VDC Models: 1221-A-48, 1221-B-48, 1221-C-48 24 VDC Models: 1221A-24, 1221-B-24, 1221-C-24 CAUTION: (Read This
More informationLDM Series Lamp Driver Modules For Graphic Annunciation and Control
12 Clintonville Road Northford, CT 06472 (203) 484-7161 FAX: (203) 484-7118 LDM Series Lamp Driver Modules For Graphic Annunciation and Control Used with the System 500, System 5000, AM2020/AFP1010 and
More informationElectricity Unit Notes. Agriculture Mechanics I
Electricity Unit Notes Agriculture Mechanics I Principles of Electricity Electricity is a form of energy that can produce light, heat, magnetism, chemical changes Resistance: tendency of a material to
More informationSLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001
SLATE Base Module R8001A1001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform can
More informationMASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc
MASTER PRESSRE MAINTANENCE CONTROLLER Models PMCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page
More informationModels NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117
Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel Revision E 61117 CAUTION: (Read This First) This panel has been designed to make it nearly bullet proof to mistakes made when wiring
More informationFMP-ULS UNIVERSAL LIQUID SENSOR INSTALLATION GUIDE
FMP-ULS UNIVERSAL LIQUID SENSOR INSTALLATION GUIDE The information in this publication is provided for reference only. While every effort has been made to ensure the reliability and accuracy of the information
More informationInstallation Instructions
Electric Heaters 5 --- 20 kw SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters For 13 SEER, R---410A, Z Chassis Installation Instructions NOTE: Read the entire instruction manual before starting
More informationKT-100 Door Controller
WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully
More informationInstallation Instructions for W2H Series Signals
Installation Instructions for W2H Series Signals IF1513 A Description and Operation DIMENSIONS W2H A 8 7/8" (225 mm) B 8 1/4" (210 mm) C 13" (330 mm) Figure 1. Speaker/Amplifier Dimensions The W2H signaling
More informationSundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A
Sundance Spas SPA EQUIPMENT SYSTEM Installation Instructions P/N 6530-456 Rev. A Contents Important Notices 1 Important Safety Instructions 2 Where to Place the Equipment System 3 Connecting Pipes Between
More informationSLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001
SLATE Burner Control Module R8001B2001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform
More informationResidual Current Devices
Residual devices F200 Series UL 1053 Residual devices F200 Series Residual Current Devices Description The F200 Series residual devices offer a wide range of product for all of your fault protection needs.
More informationInstalling the Cisco ONS FAP-4 Fuse Alarm Panel
Installing the Cisco ONS 15454-FAP-4 Fuse Alarm Panel Product Number: 15454-FAP-4= This document explains how to install, test, operate, and maintain the Cisco ONS 15454-FAP-4 fuse alarm panel. This document
More informationINSTALLATION GUIDE AND OWNER S MANUAL
INSTALLATION GUIDE AND OWNER S MANUAL SINGLE POINT, FLOW CONTROLLED and THERMOSTATIC ELECTRIC INSTANTANEOUS WATER HEATERS BEFORE ATTEMPTING ANY INSTALLATION, MODIFICATION OR SERVICE OF THIS HEATER, MAKE
More informationHOMEADVANTAGE II IMPORTANT SAFETY INFORMATION
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL HOMEADVANTAGE II HA008240 HA011240 HA013240 HA018240 HA024240 HA027240 HA036240 IMPORTANT SAFETY INFORMATION When installing or using any high voltage electrical
More informationFMP-DVS. Monitoring Well Discriminating Vapor Sensor (BriteSensor ) Installation Instructions
FMP-DVS Monitoring Well Discriminating Vapor Sensor (BriteSensor ) Installation Instructions Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608
More informationProduct Manual SZ1145
Product Manual SZ114 General Purpose Monitor Communicating Controls Description The SZ114 is a microprocessor-based monitoring and alarm interface designed to monitor up to four 1000 Ω platinum temperature
More informationEEMAX SERIES-TWO WATER HEATERS
EEMAX SERIES-TWO WATER HEATERS ELECTRIC INSTANTANEOUS WATER HEATER INSTALLATION GUIDE AND OWNERS MANUAL MODELS COVERED:- EX190 TC, T2-240/208 V EX144 TC, T2-240/208 V EX1608 TC, T2 208V EX160 TC, T2-277
More informationFireNET Plus Wiring Instructions
FireNET Plus Wiring Instructions This manual provides wiring instructions for the 1 loop and 2 loop version of the FireNET Plus panels, which supports our finest Hochiki s DCP protocol. Note: Refer to
More informationTable of Contents. Important Safety Instructions. WARNING: If the instructions contained in this manual are not followed
Table of Contents 1 Installation 6 1.1 General installation instructions 6 1.2 Electrical requirements 7 1.3 Electrical connection 8 1.4 Cable replacement 10 1.5 Positioning 10 EN Important Safety Instructions
More informationVIKING RANGE CORPORATION, P.O. DRAWER 956, GREENWOOD,MS USA
VIKING RANGE CORPORATION, P.O. DRAWER 956, GREENWOOD,MS 38930 USA TABLE OF CONTENTS VDSC ( Dual fuel ) / VESC (Electric) RANGES / VERT (Rangetop) COMPONENTS AND FUNCTIONAL PARTS: Control / Timer ------------------------------------------------------------------------------------------------------
More informationOperator: Save these instructions for future use!
50A66-743 Integrated Furnace Control Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
More informationInstallation Instructions
Installation Instructions Electric Heater Packages KFAEH -CIRCUIT GROUND LUG TERMINAL BLOCK MULTI-CIRCUIT GROUND LUG COOLING CONTROL PLATE ADAPTER PLATE (MUST BE REMOVED WHEN INSTALLING LARGE HEATER) BLOCK
More informationPre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit
Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design N56 W16665 Ridgewood Drive Menomonee Falls, WI 53051 SBS-H2 Hydrogen Gas Detector Kit For battery charging rooms and other areas where
More informationInstallation S19-324D1. Class I, Division 1, Groups C & D Explosion Proof. Emergency Signaling System
Installation S19-324D1 Class I, Division 1, Groups C & D Explosion Proof Emergency Signaling System Table of Contents Pre-Installation Information... 2-3 ssembly of Components...4 Install the Flow Switch
More informationTS-RA1, TS-RA2 and TS-RK Tank Overfill Alarms
TS-RA1, TS-RA2 and TS-RK Tank Overfill Alarms Installation Guide franklinfueling.com 3760 Marsh Rd. Madison, WI 53718, USA Tel: +1 608 838 8786 Fax: +1 608 838 6433 Tel: USA & Canada +1 800 225 9787 Tel:
More informationSentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.
Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL www.aquaticsentry.com TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 3 2. APPLICATION... 3 2.1 HIGH AND LOW LEVEL ALARM 2.2 PUMP DOWN CONTROLLER 2.3
More informationVista-50P/-50PUL System Design Sheet
Vista-50P/-50PUL System Design Sheet INTRUSION DETECTION HOLD UP CRITICAL EQUIP. SUPV. LONG RANGE RADIO ACCESS CONTROL SECTION 1: Basic Vista-50P (Nine Hardwired Zones, One Addressable Loop, Wireless)
More informationModels CHB/CCB APPLICATION GUIDE WALL MOUNTED GAS BOILER
Models CHB/CCB APPLICATION GUIDE WALL MOUNTED GAS BOILER This manual has been prepared for use with the appropriate Installation, Operation and Maintenance Manual. For use with CCB/CHB Boilers ONLY. Manufactured
More informationBeacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08
Beacon 200 Gas Monitor Operator s Manual Part Number: 71-2102RK Released: 6/6/08 Table of Contents Chapter 1: Introduction.................................................3 Overview.............................................................3
More informationFMP-DDS & FMP-DTS. Discriminating Dispenser Sump & Turbine Sump BriteSensor. Installation Instructions
& Discriminating Dispenser Sump & Turbine Sump Brite Installation Instructions Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838 6433 www.franklinfueling.com
More informationTitle: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards
Change History Date Description of Change Pages / Sections Modified Change Approver Initials 8/1/17 Updated section on Manufacturers 3 1. 6/15/16 Updated division section from 16120 to 26 05 00, - mgl44
More informationProduct Manual SZ1144
Product Manual SZ1144 Refrigeration Temperature Monitor Communicating Controls Description The SZ1144 is a microprocessor-based monitoring and alarm interface designed to monitor up to four 1000 Ω platinum
More informationWAIWELA SERIES-TWO WATER HEATERS
WAIWELA SERIES-TWO WATER HEATERS ELECTRIC INSTANTANEOUS WATER HEATER INSTALLATION GUIDE AND OWNERS MANUAL MODELS COVERED WET-12 T, TC, T2-240/208 V SPECIAL, V READ THE GENERAL SAFETY SECTION BEGINNING
More informationELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. U.S.A. WARNING FOR YOUR
More informationInstallation Instructions
Installation Instructions Free-Standing Electric Ranges Questions? Call 800.GE.CRES (800.432.2737) or Visit our Website at: ge.com EFORE YOU EGIN Read these instructions completely and carefully. IMPORTNT
More informationTABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13
R 410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H) System, DFC4(A/H)3 Outdoor, DFF4(A/H)H Indoor NOTE: Read the entire instruction manual before starting the installation.
More informationSLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001
SLATE Sub-Base Module R8001S9001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform
More informationHi-lume 3D Overview. Fluorescent Dimming Ballasts
Fluorescent Dimming s Overview 1 architectural electronic dimming ballasts are designed to meet the most demanding lighting requirements. By providing industry leading performance with a full-range of
More informationThe TC-4F. Time Control Module C P/N 15972:C ECN For the Sensican 2000 Fire Alarm Control Panel
12 Clintonville Road Northford, CT. 06472 (203) 484-7161 FAX:(203) 484-7118 The TC-4F Time Control Module For the Sensican 2000 Fire Alarm Control Panel Document # 15972 3/27/95 Revision C P/N 15972:C
More informationData Sheet. Self regulating process heating tapes RS stock numbers ,
Data Pack K Issued March 1997 232-3333 Data Sheet Self regulating process heating tapes RS stock numbers 379-889, 379-974 The information contained within this sheet regarding applications and installation
More informationAIR-COOLED CONDENSING UNIT UNITS PRODUCED AFTER JANUARY, 1996 INDEX SCHEMATIC DIAGRAM FIG. NO.
wiring diagrams AIR-COOLED CONDENSING UNIT 566D Sizes 120-240 Cancels: New WD 566D.120.1 11/15/96 UNITS PRODUCED AFTER JANUARY, 1996 INDEX UNIT 566D 120-240 ELECTRICAL CHARACTERISTICS (V-Ph-Hz) SCHEMATIC
More informationInstallation Instructions Azatrax Dual Infrared Model Train Detector MRD2 'Turnout' Edition
Installation Instructions Azatrax Dual Infrared Model Train Detector MRD2 'Turnout' Edition What it is: The MRD2 'turnout' edition is a two-channel model train detector. It can detect model trains at two
More informationDOOR MONITORING/DURESS SYSTEM
SECTION PART 1 - GENERAL 1.1 RELATED SECTIONS A. Comply with the requirements of Section 27 05 00 Common Work Results for Communications. 1.2 DEFINITIONS A. Not used. 1.3 DESCRIPTION OF SYSTEM: A. Provide
More informationRELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:
RELEASE DEVICES MADE IN THE U.S.A. RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION: S/N: The "WPS" World Power Series, Time Delay Release
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 26 0519 LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationBooster Power Supply Manual
Supply Manual DEVELOPED BY COPYRIGHT NOTICE General Signal Building Systems Corporation 6411 Parkland Drive Sarasota, FL 34243 (941) 739-4300 Copyright 1999 General Signal Building Systems Corporation
More informationInstallation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)
Installation Viking Range, LLC Front Street Greenwood, Mississippi 890 USA (66) 455-00 For product information, call -888-845-464 or visit the Viking Website at vikingrange.com U L C U L 4 Series Built-In
More informationEmergency Generator Safety
Safety Installing and Operating s Key Points of Safety Read, understand and follow the manufacturer s instructions. Operate your generator outdoors in a clean, dry, well-ventilated area, and never indoors
More informationInstallation Instructions
40MAQ High Wall Ductless System Sizes 09 to 36 Installation Instructions NOTES: Read the entire instruction manual before starting the installation. Images are for illustration purposes only. Actual models
More informationFirefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL
Firefly II Multi Voltage RELEASE DEVICES Firefly II & IIB-MV INSTALLATION MANUAL GENERAL DESCRIPTION: S/N The The Cookson Company Firefly II-MV time delay release devices are designed for use on rolling
More informationHA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE
D (OPERATION) INITIATE A DYNAMIC BATTERY TEST The system tests the back-up battery once every 24 hours. The owner can initiate a dynamic battery test at any time with the following codes while the system
More informationPRO SERIES IMPORTANT SAFETY INFORMATION
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL PRO SERIES IMPORTANT SAFETY INFORMATION When installing or using any high voltage electrical appliance, basic safety precautions should always be followed.
More informationInstruction manual. WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules
Instruction manual WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules This manual must only be used by a qualified heating installer/service technician.
More informationANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.
ANCHOR BOLT DETAIL Heavy Flat Washer Heavy Hex Nut UNC Th'd Mounting Flange Of Equipment To Be Mounted C B A D Non-Shrink Grout. Poured In Place, After Equipment Setting. Heavy Flat Washer Heavy Hex Nut
More informationInstallation Instructions
40MAQ High Wall Ductless Split System Sizes 09 to 36 Installation Instructions NOTE: Read the entire instruction manual before starting the installation TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS 2 PARTS
More informationINSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION As when installing or using any high voltage electrical appliance, basic safety precautions should always
More informationELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. FOR YOUR SAFETY: Do not
More informationIR Intelligent Positioning System Installation Manual
IR Intelligent Positioning System Installation Manual Version 1.0.0 Table of Contents 1 INSTALLATION PREPARATION... 1 1.1 Basic Requirement... 1 1.2 Installation Check... 1 1.3 Cable Preparation... 1 1.3.1
More informationSECTION RADIANT-HEATING ELECTRIC CABLES PART 1 - GENERAL 1.1 SECTIONS INCLUDES
SECTION 238313 - RADIANT-HEATING ELECTRIC CABLES PART 1 - GENERAL 1.1 SECTIONS INCLUDES A. Low-voltage Electric Snow and ice heating elements "under" finished roof materials (shingles or metal), gutters,
More informationYP7999A1000 ControLinks Fuel Air Ratio Control Panel
YP7999A1000 ControLinks Fuel Air Ratio Control Panel FEATURES INSTALLATION INSTRUCTIONS Pre-wired and ready to install Includes the R7999A control, wiring subbase and S7999D1048 touchscreen display Commission,
More informationIMPORTANT INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS. Electric Wall Panel. Owner s Manual & Installation Instructions L
Electric Wall Panel Owner s Manual & Installation Instructions 8 Element Wall Panel Front View 8 & 6 Element Wall Panel Side View 6 Element Wall Panel Back View Top 23 1 8 EWP 8 EWP 6 Bottom 17 1 4 2 3
More informationBasin Heater. user manual INSTALLATION OPERATION MAINTENANCE
user manual Basin Heater INSTALLATION OPERATION MAINTENANCE Z0238873_A ISSUED 03/2017 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. receiving and inspection The heater
More informationG71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature
Service Literature Corp. 0804 L2 Revised 05 05 2008 G71MPP G71MPP SERIES UNITS G71MPP series units are high efficiency multi position (upflow, downflow, horizontal right and left) gas furnaces equipped
More informationFlame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES
Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES 37-754 FLAME RETARDANT EP/CPE TYPE TC OR TC-ER POWER CABLE Two Five Conductor + Ground (Two, Three & Four Conductor) 600 V Rated 90 C Conductor*
More informationModel 3300 Technical Support and Installation Manual
Model 3300 Technical Support and Installation Manual Manual # T15011 Document Revision: A1 1. OVERVIEW 1 2. BASIC OPERATION 1 2.1 General 1 2.2 Field-of-View 2 2.3 Range 2 2.4 Environment 2 2.5 Configuration
More informationSLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature
Service Literature Corp. 1029 L7 SLP98UHV SLP98UHV SERIES UNITS SLP98UHV series units are high efficiency upflow, horizontal right and left) gas furnaces equipped with variable capacity gas valve, variable
More informationINSTALLATION INSTRUCTIONS. Anti Knocking System, AKR 3. Document no.: A SW version:
INSTALLATION INSTRUCTIONS Anti Knocking System, AKR 3 DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel: +45 9614 9614 Fax: +45 9614 9615 info@deifcom wwwdeifcom Document no: 4189340792A SW version: 1 General
More informationINSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.
INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3 M336 Rev F November 21, 2000 ÇConsilium Consilium US, Inc. 59 Porter Rd Littleton, MA 01460-1431 USA
More informationwww. ElectricalPartManuals. com GADD MKIII Ground Fault Indication System Instruction Manual Ground Fault Protection
Ground Fault Protection GADD MKIII Ground Fault Indication System Instruction Manual 7615 Kimbel Street, Mississauga, Ontario Canada L5S 1A8 Tel: (905)673-1553 Fax: (905)673-8472 Toll Free: 1-888-RESISTR
More informationInstallation Instructions
38MHR Outdoor Unit Single Zone Ductless System Sizes 09 to 24 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. NOTE: Images are for illustration purposes
More informationDanfoss gas detection units
Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning
More information1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR
1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR IMPORTANT: Please read these installation and operating instructions completely and carefully before
More informationInstallation Instructions
Installation Instructions Electric Heater Packages KFAEH TE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SINGLE-CIRCUIT GROUND
More informationFor technical questions, contact: Grace Engineered Products Inc./ 5001 Tremont Ave, Davenport, IA /
For technical questions, contact: Grace Engineered Products Inc./ 5001 Tremont Ave, Davenport, IA 52807 / 800.280.9517 563.386.9639 (Fax) INSTALLATION AND OPERATING INSTRUCTIONS R-3W2 UL APPROVED FOR:
More informationMEDIUM, LOW AND CONTROL VOLTAGE CABLES
Related Sections U-M Design Guideline Sections: 260800 - Electrical Acceptance Tests Products Medium Voltage Primary Cables Primary power distribution cable shall be single conductor stranded copper, with
More informationHeat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.
Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA 02717 The first totally integrated multiple boiler management control. USING THIS MANUAL USING THIS MANUAL A. INSTALLATION SEQUENCE Follow
More informationSOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL
S S S S S S LISTED L * PATENT PENDING S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT U 99Y9 RESET RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE
More informationInstallation Instructions Model CDC-4
Installation Instructions CDC-4 Conventional Card INTRODUCTION The SIEMENS CDC is a card that allows conventional detectors to be used on the FireFinder-XLS system. It provides four Class or Class B conventional
More informationHigh Speed Positioning System Installation Manual
High Speed Positioning System Installation Manual Version 1.0.0 Table of Contents 1 INSTALLATION PREPARATION... 1 1.1 Basic Requirement... 1 1.2 Installation Check... 1 1.3 Cable Preparation... 1 1.3.1
More informationANNUNCIATOR FIXED MODULE
12 Clintonville Road Northford, CT 06472 Phone: 203-484-7161 Fax: 203-484-7118 THE ANNUNCIATOR FIXED MODULE Installation Manual for the AFM-16ATF and AFM-32AF Annunciator Modules Document # 15970 3/27/95
More informationM2500 Engine Controller Installation Manual
M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...
More informationVENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS
VENSTAR FAN COIL THERMOSTAT FAN COIL THERMOSTAT T1070 NON- PROGRAMMABLE 2 OR 4 PIPE SYSTEMS Remote sensor ready 3 speed fan control Self-prompting adjustment Auto 2-pipe changeover when used with ACC-SENFC
More informationPart Number Structure ZT 028 L D CT R 15
Product Application Guide- 22mm Industrial Alarms with LED Lights Part Number Structure ZT 028 L D CT R 15 Series: ZT = 22mm with LED Maximum Voltage: 016 = 9-16; 028 = 20-28; 120 = 48-120 Sound Level:
More informationTECHNICAL DATA OBSOLETE
Deluge Devices 270a 1. PRODUCT NAME VIKING PAR-3 Available since 1991 2. MANUFACTURED FOR: THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877)
More informationSeries SPB Audio Boosters Installation, Testing, Operation, and Maintenance Manual
Series SPB Audio Boosters Installation, Testing, Operation, and Maintenance Manual Part Number P84748 Assembly Number A84749 Revision C Revision A Copyright 2006 Printed in U.S.A. All rights reserved.
More informationSecurity & Control Cables
Security & Control Cables Our multi-conductor cables are manufactured in a wide variety of gauge sizes, shielding configurations and jacketing materials including plenum, riser and general purpose. Applications
More information