INDEX. ADDITIONS AND ALTERATIONS Defined Requirements ADMINISTRATION AND ENFORCEMENT... Chapter 1 AIR ECONOMIZERS

Size: px
Start display at page:

Download "INDEX. ADDITIONS AND ALTERATIONS Defined Requirements ADMINISTRATION AND ENFORCEMENT... Chapter 1 AIR ECONOMIZERS"

Transcription

1 A ADDITIONS AND ALTERATIONS Requirements ADMINISTRATION AND ENFORCEMENT Chapter 1 AIR ECONOMIZERS Defined Requirements , , AIR INFILTRATION Requirements , , AIR LEAKAGE , Table (1), 502.4, AIR SYSTEM BALANCING ALTERNATE MATERIALS APPROVED AUTOMATIC B BALANCING , BALLASTS , BASEMENT WALLS Requirements , Table , Table , , Table (1), Table 502.2(1), , BELOW-GRADE WALLS (see BASEMENT WALLS) BI-LEVEL SWITCHING BOILERS Table (5), , , 504.2, Table BUILDING ENVELOPE Compliance documentation , Exemption Requirements , 402, 502 Performance method.... Table (1), C CAULKING AND WEATHERSTRIPPING , , CERTIFICATE CHANGE OF OCCUPANCY CIRCULATING PUMPS , CIRCULATING SYSTEMS , , , 504.6, CLIMATE ZONES , Figure 301.1, Table By state or territory..... Figure 301.1, Table International climate zones , Table 301.3(1), Table 301.3(2) Warm humid , Table 301.2, COEFFICIENT OF PERFORMANCE (COP) Table (2), Table (7), Table (8), Table (9), Table (10), Table (11) COMBINED SERVICE WATER HEATING AND SPACE HEATING COMMERCIAL BUILDINGS Compliance , , 101.5, Chapter 5, Total building performance COMMISSIONING OF HVAC SYSTEMS Manuals COMPLIANCE AND ENFORCEMENT CONDITIONED FLOOR AREA CONDITIONED SPACE CONSTRUCTION DOCUMENTS CONTROLS Capabilities , , , , , , , , Economizers , Energy recovery systems Fan speed Heat pump , , Heating and cooling , , , Hot water system Humidity , , Hydronic systems , , Lighting , , Off hour Service water heating , 504.3, Shutoff dampers , , Temperature , , , , Variable air volume systems , Ventilation COOLING WITH OUTDOOR AIR , CRAWL SPACE WALLS Requirements , Table , Table , , Table (1) 2006 INTERNATIONAL ENERGY CONSERVATION CODE 59

2 D DEADBAND , , DEFINITIONS Chapter 2 DEGREE DAY COOLING Table 301.3(2) DEGREE DAY HEATING Table 301.3(2) DESIGN CONDITIONS Chapter 3, 302 DUAL DUCT VAV , DUCTS Insulation , 401.3, 403.2, , , Sealing , , , DWELLING UNIT E ECONOMIZER Air , Requirements , , Water ELECTRICAL METERS ELECTRICAL POWER AND LIGHTING ENERGY ANALYSIS, ANNUAL Documentation , Requirements , 506 ENERGY EFFICIENCY RATIO (EER) , , ENERGY RECOVERY VENTILATION SYSTEMS Requirements... Table (1), , ENERGY SIMULATION TOOL Requirements/Use , 404, 506, , , ENVELOPE, BUILDING THERMAL ENVELOPE DESIGN PROCEDURES , 502, EQUIPMENT EFICIENCIES , 401.3, , , , 504.2, , EQUIPMENT PERFORMANCE REQUIREMENTS Boilers Table (5) Chillers, nonstandard Tables (8-10) Condensing units Table (6) Economizer exception Table (2) Heat rejection equipment Table (11) Packaged terminal air conditioners and heat pump Table (3) Unitary air conditioners and condensing units Table (1) Unitary and applied heat pumps... Table (2) Warm air duct furnaces and unit heaters Table (4) Warm air furnaces Table (4) Warm air furnaces/air-conditioning units Table (4) Water chilling packages, standard. Table (7) Water heating EXEMPT BUILDINGS EXISTING BUILDINGS EXTERIOR LIGHTING EXTERIOR SHADING Table 502.3, EXTERIOR WALLS Thermal performance , , Table (1), 502, F FENESTRATION , 402.3, , 502.3, Rating and labeling , , 402.6, FURNACE EFFICIENCY Table (1), Table (4) G GUESTROOMS (see SLEEPING UNIT) GLAZING AREA Requirements , , Table (1) H HEAT PUMP , Tables (2, 3), , HEAT TRAPS , HEATING AND COOLING LOADS , , , , , , , , , , HISTORIC BUILDINGS HOT WATER Annual energy performance , 506 Piping insulation , , System controls , 504.3, HUMIDISTAT Requirements , , HYDRONIC SYSTEM BALANCING I IDENTIFICATION (MATERIALS, EQUIPMENT AND SYSTEM) INTERNATIONAL ENERGY CONSERVATION CODE

3 INDIRECTLY CONDITIONED SPACE (see CONDITIONED SPACE) INFILTRATION, AIR LEAKAGE , Table (1), INSPECTIONS INSULATION Identification Installation , , , Requirements , 402.2, 502.1, INSULATING SHEATHING Requirements Table , , Table 502.2(1), INTEGRATED PART LOAD VALUE (IPLV) Tables (1, 2, 6, 7, 8, 9 and 10), , INTERIOR LIGHTING POWER , L LABELED Requirements , 102.3, , , , , , LIGHTING POWER Design procedures Exterior connected , Interior connected , Table , Manufacturer's information , 102.3, LIGHTING SYSTEMS Controls, additional Controls, exterior Controls, interior Guestrooms/Sleeping units Line voltage Merchandise, (highlight specific)..... Table Plug-in busway Track LISTED LOADING DOCK WEATHERSEALS LOW ENERGY BUILDINGS LOW-VOLTAGE LIGHTING Requirements LUMINAIRE Controls , Sealed , Tandem wiring Wattage , M MAINTENANCE INFORMATION MANUALS , 102.3, MASS Wall , , Table (1), Floor MATERIALS AND EQUIPMENT MECHANICAL SYSTEMS AND EQUIPMENT , 404.1, 503 MECHANICAL VENTILATION , Table (1), 503.1, METERS, ELECTRICAL MOISTURE CONTROL , MULTIPLE ZONE SYSTEMS N NONCIRCULATING SYSTEMS , NONDEPLETABLE/RENEWABLE ENERGY SOURCES Requirements O OCCUPANCY Requirements , , 101.5, , , 504.3, , OCCUPANCY SENSORS , OFF-HOUR, CONTROLS OPAQUE AREAS , 502, Table 502.2(1), ORIENTATION... Table (1), , OVERHANG, PROJECTION FACTOR P PACKAGED TERMINAL AIR CONDITIONER (PTAC) Requirements Table (3), PACKAGED TERMINAL HEAT PUMP Requirements Table (3), PARALLEL PATH CALCULATION PERFORMANCE ANALYSIS , 506 PHOTOCELL PIPE INSULATION , 403.4, , PLANS AND SPECIFICATIONS POOL COVERS POOLS PROJECTION FACTOR PROPOSED DESIGN Requirements , 506 PUMPING SYSTEMS , , , 504.6, R R-VALUE Computation RECOOLING REFERENCED STANDARDS , Chapter INTERNATIONAL ENERGY CONSERVATION CODE 61

4 REHEATING , RENEWABLE/NONDEPLETABLE ENERGY SOURCES REPAIR Requirements RESET CONTROL RESIDENTIAL BUILDINGS Compliance , Requirements Chapter 4 Simulated Performance Alternative ROOF ASSEMBLY Requirements , , , Table (1), , S SCOPE SCREW LAMP HOLDERS Requirements SEASONAL ENERGY EFFICIENCY RATIO (SEER) , SERVICE WATER HEATING Requirements , 403.4, 404.1, 501.2, , 504, , , , SETBACK THERMOSTAT SHADING Projection factor SHEATHING, INSULATING (see INSULATING SHEATHING) SHGC (see SOLAR HEAT GAIN COEFFICIENT) SHUTOFF DAMPERS , , SIMULATED PERFORMANCE ALTERNATIVE , 506 SIMULATION TOOL (see ENERGY SIMULATION TOOL) SINGLE ZONE , SIZING Equipment and system , , SKYLIGHTS , 402.3, , , , 402.6, Table (1), , , Maximum exempt area SLAB-EDGE INSULATION , 401.3, Table , , SLEEPING UNIT , , SOLAR HEAT GAIN COEFFICIENT (SHGC) , 104.2, 401.3, Table , , , , , 402.6, , Table 502.3, STANDARD REFERENCE DESIGN Requirements , 506 STANDARDS, REFERENCED , Chapter 6 STOREFRONT , Table 502.3, STEEL FRAMING , Table 502.2(2) SUNROOM , , Table (1) SUSPENDED CEILINGS SWIMMING POOLS T TANDEM WIRING TERMITE INFESTATION THERMAL ISOLATION , , Table (1) THERMAL MASS (see MASS) THERMAL RESISTANCE (see R-VALUE) THERMAL TRANSMITTANCE (see U-FACTOR) TOTAL BUILDING PERFORMANCE Commercial Residential TOWNHOUSE (see RESIDENTIAL BUILDINGS) U U-FACTOR Alternative , V VAPOR RETARDER , 402.5, VARIABLE AIR VOLUME SYSTEMS (VAV) , , , VENTILATION , 403.5, Table (1), , VESTIBULES W WALL Above grade, defined Basement, defined Crawlspace, defined Exterior, defined WALLS (see EXTERIOR WALLS AND ENVELOPE, BUILDING THERMAL) WALLS ADJACENT TO UNCONDITIONED SPACE (see BUILDING THERMAL ENVELOPE) WATER ECONOMIZER INTERNATIONAL ENERGY CONSERVATION CODE

5 WATER HEATING , 504, , WINDOW AREA (see FENESTRATION and GLAZING AREA) WINDOW PROJECTION FACTOR Requirements WIRING, TANDEM Z ZONE (see also CLIMATE ZONES) Requirements , , 503.3, , ZONE ISOLATION INTERNATIONAL ENERGY CONSERVATION CODE 63

6 INTERNATIONAL ENERGY CONSERVATION CODE

August 15, 2013 Page 1 of 19

August 15, 2013 Page 1 of 19 Section C401 Application Compliance with C402, C403, C404 and C405 AND (either C406.2, C406.3 or C406.4) Compliance with C402, C403, C404 or C405 Section C402 Building Envelope (Climate Zone 5A) Space-Conditioning

More information

ASHRAE/IESNA Standard

ASHRAE/IESNA Standard ASHRAE/IESNA Standard 90.1-1999 An inside look at the requirements of Standard 90.1-1999 Energy Standard for Building Except Low-Rise Residential Building Mick Schwedler, PE Sr. Principal Applications

More information

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is. 2018 NC Energy Conservation Code Commercial Mechanical Module 7 CHAPTER 5 [CE] WORKSHEET 1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the

More information

COMMERCIAL ENERGY EFFICIENCY

COMMERCIAL ENERGY EFFICIENCY CHAPTER 5 COMMERCIAL ENERGY EFFICIENCY This chapter has been reformatted; some deletions are not marked. SECTION 501 GENERAL 501.1 Scope. The requirements contained in this chapter are applicable to commercial

More information

COMMERCIAL ENERGY EFFICIENCY

COMMERCIAL ENERGY EFFICIENCY CHAPTER 5 COMMERCIAL ENERGY EFFICIENCY SECTION 501 GENERAL 501.1 Scope. The requirements contained in this chapter are applicable to commercial buildings, or portions of commercial buildings and to multiple-family

More information

Energy-Efficiency Measures List

Energy-Efficiency Measures List Guidelines for Public Agencies Energy-Efficiency Measures List 1.0 Envelope 1.1 Reduce Heat Losses-Ceiling/roof 1.11 Additional Ceiling/Roof Insulation 1.12 Exhaust Attics 1.13 Use Light-Colored Roof Surfaces

More information

2009 IECC Commercial Mechanical Requirements

2009 IECC Commercial Mechanical Requirements BUILDING ENERGY CODES UNIVERSITY 2009 IECC Commercial Mechanical Requirements Ken Baker PNNL-SA-66171 Learning(Objec-ves(( ( 1. Find(minimum(equipment(efficiency(requirements( and(recite(at(least(3(common(terms(for(measuring(

More information

COMcheck Software Version Review Mechanical Compliance Certificate

COMcheck Software Version Review Mechanical Compliance Certificate COMcheck Software Version 4.0.7.2 Review Mechanical Compliance Certificate Section 1: Project Information Energy Code: 2014 Oregon Energy Efficiency Specialty Code Project Title: Benton County Health Project

More information

Facility information. Building Envelope

Facility information. Building Envelope ENERGY AUDIT CHECKLIST A school building or community center is more than just a set of rooms and offices; it is a living structure. Energy flows through the building just like any living thing. Buildings

More information

HVAC Mandatory Provisions Part II, Page 1

HVAC Mandatory Provisions Part II, Page 1 HVAC Mandatory Provisions Part II, Page 1 Mandatory Equipment Efficiency Worksheet (6.4.1.1) System Equipment Type Size Category (Tables 6.8.1A through K) Sub-Category or Rating Condition Units of Efficiency

More information

2011 Manitoba Energy Code for Buildings (MECB) PART 5, Heating, Ventilating and Air-conditioning Systems

2011 Manitoba Energy Code for Buildings (MECB) PART 5, Heating, Ventilating and Air-conditioning Systems 2011 Manitoba Energy Code for Buildings (MECB) PART 5, Heating, Ventilating and Air-conditioning Systems Dieter Bartel, Manitoba Hydro September 17 th, 2014 Outline Scope and compliance Prescriptive path

More information

Application of the 2012 North Carolina Energy Conservation Code

Application of the 2012 North Carolina Energy Conservation Code Application of the 2012 North Carolina Energy Conservation Code Commercial Mechanical Presented By: NC Code Officials Qualification Board Office of State Fire Marshal NC Department of Insurance 2012 Modules

More information

2018 International Energy Conservation Code (IECC) Updates

2018 International Energy Conservation Code (IECC) Updates Providing effective energy strategies for buildings and communities 2018 International Energy Conservation Code (IECC) Updates 04.04.2018 12PM CDT Who we are Our goal: Reduce the energy footprint of Illinois.

More information

COMcheck Software Version Interior Lighting Compliance Certificate

COMcheck Software Version Interior Lighting Compliance Certificate Section 1: Project Information Energy Code: 2009 IECC Project Type: New Construction COMcheck Software Version 4.0.2.8 Interior Lighting Compliance Certificate Construction Site: Owner/Agent: Designer/Contractor:

More information

ONTARIO BUILDING CODE AND SUPPLEMENTARY STANDARD SB-10 PROJECT INFORMATION. Mechanical Designer Information*

ONTARIO BUILDING CODE AND SUPPLEMENTARY STANDARD SB-10 PROJECT INFORMATION. Mechanical Designer Information* ONTARIO BUILDING CODE AND SUPPLEMENTARY STANDARD SB-10 PROJECT INFORMATION Project: Building Permit Application No.: DETAILED FORMS Location: Date: Architectural Designer Information* Mechanical Designer

More information

Small Building Program Design Phase Assistance

Small Building Program Design Phase Assistance Small Building Program Design Phase Assistance Customer s Facility/Project Location XXXX/YYY, MA Project Team (if selected) Contact Firm Phone Email Customer: Electric PA: Gas PA: PAs s Technical Consultant:

More information

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning HVAC 101 The Basics of Heating, Ventilation and Air Conditioning HVAC Heating, Ventilation and Air Conditioning Provides comfort for people Allows humans to exist under adverse conditions. Comfort Comfort

More information

1. Dial Down. 10 Energy Saving Tips for the Home

1. Dial Down. 10 Energy Saving Tips for the Home 1. Dial Down 10 Energy Saving Tips for the Home Dial Down Turn the thermostat down in the winter & up in summer. You save about 2% to 3% on your heating bill for every 1º that you lower the thermostat

More information

NAHB Green Home Building Guidelines. 3.1 Prerequisites. ResCheck. Energy Efficiency

NAHB Green Home Building Guidelines. 3.1 Prerequisites. ResCheck. Energy Efficiency NAHB Green Home Building Guidelines Energy Efficiency 3.1 Prerequisites 3.1.1 Home is equivalent to the IESS 2003 or local energy code. Conformance shall be based on plan analysis using software. 3.1.2

More information

Strategies for Building Energy Efficiency

Strategies for Building Energy Efficiency Strategies for Building Energy Efficiency Ben Sliwinski Technical Director SEDAC University of Illinois at Urbana-Champaign How Buildings Use Energy Building Envelope (Walls, Roof, Windows, Floors) Lighting

More information

High Performance Building Guide 1

High Performance Building Guide 1 Description This Guide is intended to be used for projects with a Vermont Certified: High Performance energy efficiency goal. This High Performance goal is a whole-building efficiency approach rather than

More information

SESSION Michigan Energy Code (MEC) Update (3 Technical) Per SMACNA Standard (TAB, Duct Design) and ASHRAE ( ) ASHRAE Detroit Members:

SESSION Michigan Energy Code (MEC) Update (3 Technical) Per SMACNA Standard (TAB, Duct Design) and ASHRAE ( ) ASHRAE Detroit Members: SESSION 1-2015 Michigan Energy Code (MEC) Update (3 Technical) Per SMACNA Standard (TAB, Duct Design) and ASHRAE (90.1.2013) ASHRAE Detroit Members: AM Session is eligible for (X) Professional Development

More information

RESNET Rating Field Inspector Field Evaluation Form

RESNET Rating Field Inspector Field Evaluation Form RESNET Rating Field Inspector Field Evaluation Form This form shall be used for 3 mentored inspections and the final field evaluation. Forms and photos must be kept for a minimum of 3 years. RESNET may

More information

1 Exam Prep Energy Efficient Building Construction in Florida Questions

1 Exam Prep Energy Efficient Building Construction in Florida Questions 1 Exam Prep Energy Efficient Building Construction in Florida Questions 1. What activates the pump on a thermosiphon solar hot water heating system? A. Holding tank sensor B. Collector sensor C. The difference

More information

INTRODUCTION TO: ASHRAE STANDARD 90.1, HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings

INTRODUCTION TO: ASHRAE STANDARD 90.1, HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings INTRODUCTION TO: ASHRAE STANDARD 90.1, 2013 HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings Rocky Mountain ASHRAE Technical Conference, April 29, 2016 SEAN BEILMAN, P.E.,

More information

ERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD (I-P Edition) Energy Standard for Buildings Except Low-Rise Residential Buildings.

ERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD (I-P Edition) Energy Standard for Buildings Except Low-Rise Residential Buildings. ERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD 90.1-2013 (I-P Edition) Energy Standard for Buildings Except Low-Rise Residential Buildings July 7, 2017 The corrections listed in this errata sheet apply to ANSI/ASHRAE/IES

More information

Missouri HERO Program Residential Eligible Product List

Missouri HERO Program Residential Eligible Product List All Products In addition to the HERO Product Eligibility Specifications listed below, it is the sole responsibility of the HERO Contractor and property owner (Project Stakeholders) to meet or exceed applicable

More information

1 - This title will copy onto other forms Date

1 - This title will copy onto other forms Date 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Summary MECH-SUM Project Title: 1 - This title will copy onto other forms Date 1/1/2015

More information

COMMERCIAL ENERGY EFFICIENCY

COMMERCIAL ENERGY EFFICIENCY CHAPTER 5 COMMERCIAL ENERGY EFFICIENCY SECTION 501 GENERAL 501.1 Scope. The requirements contained in this chapter are applicable to commercial buildings, or portions of commercial buildings. These commercial

More information

SUPPORTING DOCUMENT RESIDENTIAL ENERGY CODE WORKSHEET (2015) EFFECTIVE JANUARY 1, 2017

SUPPORTING DOCUMENT RESIDENTIAL ENERGY CODE WORKSHEET (2015) EFFECTIVE JANUARY 1, 2017 SUPPORTING DOCUMENT RESIDENTIAL ENERGY CODE WORKSHEET (2015) EFFECTIVE JANUARY 1, 2017 The Residential Energy Code Worksheet is a tool to help you plan your energy code needs for new or remodeled homes,

More information

Address Account # Member # Equipment Specifications Quantity Rebate. ENERGY STAR Appliances

Address Account # Member # Equipment Specifications Quantity Rebate. ENERGY STAR Appliances Rebate not to exceed cost of high efficiency equipment. Equipment must be purchased or recycled in 2015. Installed equipment must be on cooperative's lines. Submit the documentation listed below no later

More information

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University AIR-CONDITIONING SYSTEMS AND APPLICATIONS Abdullah Nuhait Ph D. King Saud University AIR-CONDITIONING SYSTEMS Earliest air conditioning system used only for heating (winter) Provided heated air for comfort

More information

Course Description... 3 Learning Objectives... 3 Introduction to Florida Building Codes... 4

Course Description... 3 Learning Objectives... 3 Introduction to Florida Building Codes... 4 Advanced Florida Building Code, 2010, including the Electrical Provisions of the Building, Energy Conservation, Residential, and Existing Building Volumes Internet Table of Contents Course Description...

More information

2006 Washington State Nonresidential Energy Code Compliance Form Washington State Nonresidential Energy Code Compliance Forms Revised July 2007

2006 Washington State Nonresidential Energy Code Compliance Form Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Mechanical Summary 2006 Washington State nresidential Energy Code Compliance Form MECH-SUM 2006 Washington State nresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address

More information

Summary Comparison of Simulation Program Features

Summary Comparison of Simulation Program Features Summary Comparison of Simulation Program Features FEATURE DOE2.2 equest TRACE 700 HAP Public/Proprietary Public Domain Proprietary Proprietary Proprietary Simulation Method 8760 hours 8760 hours 8760 hours

More information

2008 Residential ACM Manual June 2007 Workshop Draft Page 1

2008 Residential ACM Manual June 2007 Workshop Draft Page 1 2008 Residential ACM Manual June 2007 Workshop Draft Page 1 2. Standard Reports 2.1 General For consistency and ease of enforcement, the manner in which building features are reported by ACMcompliance

More information

Equipment Specifications and Required Information Quantity Rebate

Equipment Specifications and Required Information Quantity Rebate Rebate not to exceed 50% of the cost of equipment. Recycling rebates qualify for the entire rebate, regardless of the recycling cost. Equipment must be purchased or recycled in 2016. Installed equipment

More information

Building Division WSEC & IRC Ventilation (Effective July 1, 2016) Residential Buildings Prescriptive Compliance Form

Building Division WSEC & IRC Ventilation (Effective July 1, 2016) Residential Buildings Prescriptive Compliance Form Residential Please Energy & Submit IRC Ventilation two (2) Prescriptive copies Compliance Fm Effective 7-1-2016 (F hardcopy submittals: please submit 2 copies) Building Division 801 228 th Ave SE Sammamish,

More information

COMcheck Software Version Mechanical Compliance Certificate

COMcheck Software Version Mechanical Compliance Certificate COMcheck Software Version 3.8.2 Mechanical Compliance Certificate 90.1 (2007) Standard Section 1: Project Information Project Type: New Construction Project Title : Rudy's Star Motors Construction Site:

More information

UPGRADES. [Energy Efficiency] Base Points

UPGRADES. [Energy Efficiency] Base Points SmartRegs Prescriptive Pathway Property Address: Dates of Inspections and Updates: Inspector: Owner: Agent: 123 Boulder Initial Inspection Date: Update Date: 7/9/5 Scott Home Inspection Unit: Compliance

More information

2012 NC Building Code Chapter 2, 602.4, , , Chapter 35 Cross-Laminated Timber. ( Item B-1)

2012 NC Building Code Chapter 2, 602.4, , , Chapter 35 Cross-Laminated Timber. ( Item B-1) 2012 NC Building Code Chapter 2, 602.4, 2302.1, 2303.1.4, Chapter 35 Cross-Laminated Timber. (141209 Item B-1) (Add a definition in Chapter 2) [BS] CROSS-LAMINATED TIMBER. A prefabricated engineered wood

More information

Direct Install Program Eligible Measures Listing:

Direct Install Program Eligible Measures Listing: Direct Install Program Eligible Measures Listing: a) Lighting: - DLC qualified LED Luminaires including LED linear tube replacements - Energy Star Approved LED Screw In Lamps - T8 fixture replacements

More information

COMcheck Software Version Mechanical Compliance Certificate

COMcheck Software Version Mechanical Compliance Certificate COMcheck Software Version 4.0.6.2 Mechanical Compliance Certificate Project Information Energy Code: Location: Climate Zone: Project Type: 90.1 (2007) Standard HALCYON Bldg. 400 Alpharetta, Georgia 3a

More information

2009 Washington State Non-Residential Energy Code Scott Rushing, PE, LEED AP - Rushing Company Lisa Rosenow, CSBA, LEED AP NEEC

2009 Washington State Non-Residential Energy Code Scott Rushing, PE, LEED AP - Rushing Company Lisa Rosenow, CSBA, LEED AP NEEC 2009 Washington State Non-Residential Energy Code Scott Rushing, PE, LEED AP - Rushing Company Lisa Rosenow, CSBA, LEED AP NEEC Mechanical Systems Agenda Changes in NREC Chapter 11 Changes in NREC Chapter

More information

COMcheck Software Version Mechanical Compliance Certificate

COMcheck Software Version Mechanical Compliance Certificate COMcheck Software Version 4.0.8.1 Mechanical Compliance Certificate Project Information Energy Code: Location: Climate Zone: Project Type: 90.1 (2013) Standard Buda, Texas 2a New Construction Construction

More information

b) Medium dwelling units that are not included in (a) above {small dwelling}, OR (c) below {large dwelling} Requires 3.5 credits

b) Medium dwelling units that are not included in (a) above {small dwelling}, OR (c) below {large dwelling} Requires 3.5 credits MASON COUNTY DEPARTMENT OF COMMUNITY SERVICES BUILDING DIVISION SHELTON (360) 427-9670 BELFAIR (360) 275-4467 Elma (360) 482-5269 FAX: (360) 427-7798 WEB SITE: www.co.mason.wa.us 615 W ALDER STREET, SHELTON

More information

Total Credits 0.00 *Please refer to Table R406.2 for complete option descriptions

Total Credits 0.00 *Please refer to Table R406.2 for complete option descriptions Prescriptive Energy Code Compliance f All Climate Zones in Washington Project Infmation Contact Infmation This project will use the requirements of the Prescriptive Path below and incpate the the minimum

More information

COMcheck Software Version Mechanical Compliance Certificate

COMcheck Software Version Mechanical Compliance Certificate COMcheck Software Version 4.0.3.0 Mechanical Compliance Certificate Section 1: Project Information Energy Code: 2014 Oregon Energy Efficiency Specialty Code Project Title: AHSC (Asian Heal Service Center

More information

2015 RESIDENTIAL ENERGY CODE WORKSHEET BPA LOG# for Prescriptive Energy Code Compliance

2015 RESIDENTIAL ENERGY CODE WORKSHEET BPA LOG# for Prescriptive Energy Code Compliance 2015 RESIDENTIAL ENERGY CODE WORKSHEET BPA LOG# f Prescriptive Energy Code Compliance FIRST, meet the minimum Washington State Energy Code Requirements: MEDIUM DWELLING UNIT: 3.5 POINTS All dwelling units

More information

Residential New Home Construction Checklist

Residential New Home Construction Checklist Residential New Home Construction Checklist A separate permit is required for each address. Address/PID: All materials and the installation of all materials must comply with the Minnesota State Building

More information

CHAPTER 4. HVAC DELIVERY SYSTEMS

CHAPTER 4. HVAC DELIVERY SYSTEMS CHAPTER 4. HVAC DELIVERY SYSTEMS 4.1 Introduction 4.2 Centralized System versus Individual System 4.3 Heat Transfer Fluids 4.4 CAV versus VAV Systems 4.5 Common Systems for Heating and Cooling 4.6 Economizer

More information

ASHRAE WILL GIVE YOU THE WORLD. This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee

ASHRAE WILL GIVE YOU THE WORLD. This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee ASHRAE WILL GIVE YOU THE WORLD This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee Complete the Distinguished Lecturer Event Summary Critique CTTC

More information

PRINCIPLES OF HEATING, VENTILATION AND AIR CONDITIONING with Worked Examples

PRINCIPLES OF HEATING, VENTILATION AND AIR CONDITIONING with Worked Examples PRINCIPLES OF HEATING, VENTILATION AND AIR CONDITIONING with Worked Examples This page intentionally left blank PRINCIPLES OF HEATING, VENTILATION AND AIR CONDITIONING with Worked Examples Nihal E Wijeysundera

More information

Massachusetts Energy Code Compliance Support Commercial Energy Code Building Mechanical & Service Water Heating Provisions

Massachusetts Energy Code Compliance Support Commercial Energy Code Building Mechanical & Service Water Heating Provisions Massachusetts Energy Code Compliance Support 2015 Commercial Energy Code Building Mechanical & Service Water Heating Provisions Codes and Standards Initiative - Sponsors Your Instructor Stephen Turner

More information

Rebate Catalog. Save money on qualified Home Cooling Systems, Appliances and more. Read about rebates for your home and business at mid.

Rebate Catalog. Save money on qualified Home Cooling Systems, Appliances and more. Read about rebates for your home and business at mid. Rebate Catalog Save money on qualified Home Cooling Systems, Appliances and more. Read about rebates for your home and business at mid.org/rebates REV 12.31.2018 How to apply Modesto Irrigation District

More information

CHAPTER 6 [CE] REFERENCED STANDARDS

CHAPTER 6 [CE] REFERENCED STANDARDS CHAPTER 6 [CE] REFERENCED STANDARDS User note: About this chapter: Chapter 6 lists the full title, edition year and address of the promulgator for all standards that are referenced in the code. The section

More information

Design Architect s/applicant s Certification Of Threshold Criteria

Design Architect s/applicant s Certification Of Threshold Criteria Design Architect s/applicant s Certification Of Threshold Criteria The Agency has requested certain certifications from the architect and applicant in connection with the submission of an application.

More information

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter Adopt Entire Chapter as amended (amended sections listed below)

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter Adopt Entire Chapter as amended (amended sections listed below) CALIFORNIA MECHANICAL CODE MATRIX ADOPTION TABLE APPENDIX E SUSTAINABLE PRACTICES (Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency authority

More information

2018 Rebate Catalog and Application

2018 Rebate Catalog and Application BUSINESS 2018 Rebate Catalog and Application Save money on qualified Lighting, Refrigeration, Appliances and more. Read about rebates for your home and business at mid.org/rebates REV01.2018 Refrigeration

More information

PRE-PRINT APPENDIX E GREEN MECHANICAL CODE SUPPLEMENT

PRE-PRINT APPENDIX E GREEN MECHANICAL CODE SUPPLEMENT GREEN MECHANICAL CODE SUPPLEMENT E 101.0 General. E 101.1 Scope Applicability. The purpose of this appendix is to provide a comprehensive set of technically sound provisions that encourage sustainable

More information

Mechanical Compliance Certificate

Mechanical Compliance Certificate COMcheck Software Version 4.0.7.0 Mechanical Compliance Certificate Project Information Energy Code: Location: Climate Zone: Project Type: 90.1 (2013) Standard Austin, Texas 2a (weather data: TBD) New

More information

Inspection Phase Three. Mechanical, Electrical & Plumbing Section 503

Inspection Phase Three. Mechanical, Electrical & Plumbing Section 503 Inspection Phase Three Mechanical, Electrical & Plumbing Section 503 COMCheck Mechanical Field Inspection Checklist Mechanical Mechanical, Electrical & Plumbing Equipment Efficiencies But a lot ore too

More information

C.E.P., C.E.M, C.I.P.E.

C.E.P., C.E.M, C.I.P.E. Subject What everyone needs to know about ASHRAE 90.1 J. Christopher Larry, P.E., C.E.P., C.E.M, C.I.P.E. Thursday, Joint ASHRAE AEE Meeting Cleveland, Ohio Introduction J. Christopher Larry P.E., C.E.P.,

More information

CHAPTER 6 REFERENCED STANDARDS. American Architectural Manufacturers Association 1827 Walden Office Square Suite 550 Schaumburg, IL

CHAPTER 6 REFERENCED STANDARDS. American Architectural Manufacturers Association 1827 Walden Office Square Suite 550 Schaumburg, IL CHAPTER 6 REFERENCED STANDARDS This chapter lists the standards that are d in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard

More information

ENERGY SYSTEMS LABORATORY

ENERGY SYSTEMS LABORATORY ESL-TR-8-11-2 RECOMMENDATIONS FOR 15% ABOVE-CODE ENERGY EFFICIENCY MEASURES ON IMPLEMENTING HOUSTON AMENDMENTS TO SINGLE-FAMILY BUILDINGS IN HOUSTON TEXAS Zi Liu, Ph.D. Jaya Mukhopadhyay Mini Malhotra

More information

STATE UNIVERSITY OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK

STATE UNIVERSITY OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK STATE UNIVERSITY OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK COURSE OUTLINE ACHP 244 AIR CONDITIONING II Prepared By: CHARLES STEAD Updated By: Michael J. Newtown, P.E. CANINO SCHOOL OF ENGINEERING

More information

2009 Washington State Energy Code Residential Sections

2009 Washington State Energy Code Residential Sections 2009 Washington State Energy Code Residential Sections Gary Nordeen, Luke Howard, Emily Salzberg (360) 956-2042 energycode@energy.wsu.edu Produced with funding from: 1 WSEC text Washington State University

More information

2018 Rebate Catalog and Application

2018 Rebate Catalog and Application 2018 Rebate Catalog and Application Save money on qualified Home Cooling Systems, Appliances and more. Read about rebates for your home and business at mid.org/rebates REV 01.2018 Modesto Irrigation District

More information

CHAPTER 5 REFERENCED STANDARDS. American Architectural Manufacturers Association 1827 Walden Office Square Suite 550 Schaumburg, IL

CHAPTER 5 REFERENCED STANDARDS. American Architectural Manufacturers Association 1827 Walden Office Square Suite 550 Schaumburg, IL CHAPTER 5 REFERENCED STANDARDS This chapter lists the standards that are d in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard

More information

A full list of energy conservation opportunities (ECO) for air-conditioned buildings

A full list of energy conservation opportunities (ECO) for air-conditioned buildings A full list of energy conservation opportunities (ECO) for air-conditioned buildings Team France (Project coordinator) Armines - Mines de Paris Austria Austrian Energy Agency Belgium Université de Liège

More information

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012 HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O INTRODUCTION HVAC systems or Heating, Ventilating and Air-Conditioning systems control the environment for people and equipment in our facilities.

More information

TABLE OF CONTENTS. Part I Administrative... 1

TABLE OF CONTENTS. Part I Administrative... 1 Part I Administrative............................ 1 CHAPTER 1 Deleted Part II Definitions.............................. 3 CHAPTER 2 DEFINITIONS.................... 3 R201 General..................................

More information

Energy Effcient Home Construction

Energy Effcient Home Construction Energy Effcient Home Construction TABLE OF CONTENTS ENERGY SAVINGS - TWO PLANS... 1 REQUIRED FEATURES CHART... 2 THE ELECTRIC HEAT PUMP... 4 ELECTRIC HEATING COST CHART... 5 AIR SEALING... 6 INSULATION...

More information

TABLE OF CONTENTS. Part I Administrative

TABLE OF CONTENTS. Part I Administrative Part I Administrative.......................... 1-1 CHAPTER 1 SCOPE AND ADMINISTRATION. 1-1 R101 General............................. 1-1 R102 Applicability......................... 1-2 R103 (Not adopted)........................

More information

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney FAST AND ROBUST BUILDING SIMULATION SOFTWARE Chilled Beam Performance: 1 Shelly Street, Sydney 3D Model Creation 1 Shelley Street, Sydney 3D Model Creation 1 Shelley Street, Sydney Daylight Analysis 1

More information

Intermediate framed denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation.

Intermediate framed denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. CITY OF PORT ORCHARD Permit Center Office located at 720 Prospect Street Mailing address: 216 Prospect Street Pt Orchard, WA 98366 (360) 874-5533 permitcenter@cityofptchard.us RESIDENTIAL ENERGY CODE WORKSHEET

More information

HVAC Controls Upgrades: Requirement Details ( )

HVAC Controls Upgrades: Requirement Details ( ) REQUIRED CONTROLS/FEATURES HVAC non CENTRAL PLANT 1) Zone Level Scheduling & Override for all air handlers (supply and exhaust) to match occupied hours by zone DDC or occupancy sensors (OS) allowed. (403.2.4.3,

More information

COMcheck Software Version Interior Lighting Compliance Certificate

COMcheck Software Version Interior Lighting Compliance Certificate Section 1: Project Information Energy Code: 2009 IECC Project Title: Berry Farms Animal Hospital Project Type: New Construction COMcheck Software Version 4.0.3.0 Interior Lighting Compliance Certificate

More information

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney Frenger Radiant chilled beam performance at 3D Model Creation Daylight Analysis Comparison of the performance of various HVAC systems at 1 Shelly St, Sydney VAV fancoil Active chilled beam Passive chilled

More information

DRAFT NATIONAL ENERGY CONSERVATION CENTRE (ENERCON) PAKISTAN ENGINEERING COUNCIL (PEC) -1-

DRAFT NATIONAL ENERGY CONSERVATION CENTRE (ENERCON) PAKISTAN ENGINEERING COUNCIL (PEC) -1- DRAFT NATIONAL ENERGY CONSERVATION CENTRE (ENERCON) PAKISTAN ENGINEERING COUNCIL (PEC) 2011-1- PREFACE Introduction Pakistan is facing a huge energy shortfall. On one hand, this has led to extended blackouts

More information

b.) Technical Information:

b.) Technical Information: Section VI- Strategies a.) Summary: It is important for new construction designers to consider the heating, ventilation, and air conditioning needs within a building. There are many different systems,

More information

TABLE OF CONTENTS. Part I Administrative... 1

TABLE OF CONTENTS. Part I Administrative... 1 Part I Administrative............................ 1 CHAPTER 1 ADMINISTRATION............... 1 R101 Title, Scope and Purpose.................... 1 R102 Applicability.............................. 1 R103

More information

MAKING IT GREEN AND SAVING ENERGY WITH NSP

MAKING IT GREEN AND SAVING ENERGY WITH NSP MAKING IT GREEN AND SAVING ENERGY WITH NSP Florida Housing Coalition Annual Conference September 2012 NSP PROGRAM BACKGROUND $ 3,296,917 in funding provided by Martin County 23 units of housing purchased

More information

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline ME 414/514 HVAC Systems Overview Equipment Outline 2-1 The Complete System 2-2 The Air-Conditioning and Distribution System 2-3 Mechanical Equipment Air-handling Equipment Heating Equipment Boilers Furnaces

More information

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment. SECTION 23 09 93 - SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1 WORK INCLUDES A. Base Bid: Heating Contractor provide: Control sequences for HVAC systems, subsystems, and equipment. B. Alternate

More information

Appendix 13. Categories of Cooling and Heating systems

Appendix 13. Categories of Cooling and Heating systems EcoShopping - Energy efficient & Cost competitive retrofitting solutions for Shopping buildings Co-funded by the European Commission within the 7 th Framework Programme. Grant Agreement no: 609180. 2013-09-01

More information

PG&E 2014 Title 24 Extension Products Products were extended through July 1, 2014

PG&E 2014 Title 24 Extension Products Products were extended through July 1, 2014 Midstream PG&E 2014 Title 24 Extension Products Products were extended through July 1, 2014 FAMILY CODE DESCRIPTION IMPACTED DISCONTINUATION LED Refrigerated Case Lights with Occupancy Sensors occupancy

More information

2015 MECHANICAL CODE REQUIREMENTS

2015 MECHANICAL CODE REQUIREMENTS 2015 MECHANICAL CODE REQUIREMENTS ANTRIM COUNTY BUILDING DEPARTMENT PO BOX 188 205 CAYUGA STREET BELLAIRE, MI 49615 (231) 533-8373 FAX (231) 533-6041 Mechanical requirements for residential buildings per

More information

REQUIRED CONTRACT DETAIL. $2, , Direct DC Fuel Cell Power System, Stationary PACE Power output < 40 kw

REQUIRED CONTRACT DETAIL. $2, , Direct DC Fuel Cell Power System, Stationary PACE Power output < 40 kw Residential Eligible Improvements and Guidelines FLORIDA To qualify for Ygrene funding, all project improvements must meet or exceed applicable local, state and federal codes and standards, and be installed

More information

BSC Building America High Performance Homes: Today & Tomorrow. Peter Yost Senior Building Scientist

BSC Building America High Performance Homes: Today & Tomorrow. Peter Yost Senior Building Scientist BSC Building America High Performance Homes: Today & Tomorrow Peter Yost Senior Building Scientist Building America homes... create energy efficient environments that: - are affordable to operate - use

More information

2007 CALIFORNIA BUILDING CODE & 2008 BUILDING ENERGY EFFICIENCY STANDARDS

2007 CALIFORNIA BUILDING CODE & 2008 BUILDING ENERGY EFFICIENCY STANDARDS 2007 CALIFORNIA BUILDING CODE & 2008 BUILDING ENERGY EFFICIENCY STANDARDS STANDARDS REVIEW WITH WATER HEATER PERMIT APPLICATION ATTENTION CONTRACTORS AND HOMEOWNERS NEW REQUIREMENTS FOR WATER HEATERS ON

More information

COMcheck Software Version Mechanical Compliance Certificate

COMcheck Software Version Mechanical Compliance Certificate COMcheck Software Version 4.0.4. Mechanical Compliance Certificate Project Information Energy Code: Location: Climate Zone: Project Type: 205 IECC Dallas, Texas 3a New Construction Construction Site: 56

More information

Ways to Save. Energy efficiency tips to help you lower your monthly power bill. 1 Ways To Save

Ways to Save. Energy efficiency tips to help you lower your monthly power bill. 1 Ways To Save Ways to Save Energy efficiency tips to help you lower your monthly power bill 1 Ways To Save 2 Ways To Save Money Saving Advice Jackson EMC is a good resource to use in your energy planning. We can show

More information

Residential Energy Efficiency Measures

Residential Energy Efficiency Measures Residential Energy Efficiency Measures Introduction There are a number of cost-effective energy saving technologies, design strategies, construction methods and operational techniques to optimize the energy

More information

In Book I, Division A, Part 1, Council adds the following definitions in alphabetical order:

In Book I, Division A, Part 1, Council adds the following definitions in alphabetical order: The following consolidated text of Part 10 of the VBBL is for information only, is intended to represent the Part 10 of the VBBL in effect as of January 1, 2019. Important text in other sections related

More information

Basic Home Energy Audit

Basic Home Energy Audit Basic Home Energy Audit The purpose of this information is to help you perform your own basic home energy audit. Improved energy efficiency can contribute to lower bills, increased comfort, lower utility

More information

Residential HVAC System Design

Residential HVAC System Design Residential HVAC System Design Crosswalk to NATE Competencies and Tasks The following North American Technical Excellence (NATE) competencies and tasks are covered in this publication. These competencies

More information

Retrofit Descriptions

Retrofit Descriptions Appendix C Retrofit Descriptions This appendix includes descriptions of 52 possible retrofits to buildings. The set includes descriptions of seven active and passive solar retrofits for which costs and

More information

RESNET HERS Rater Sample Test Questions 2

RESNET HERS Rater Sample Test Questions 2 RESNET HERS Rater Sample Test Questions 2 1. Which of the following is the best device for removing standing water from a crawl space? A. Dehumidifier B. Sump pump C. Air-to-air heat exchanger D. Crawl-space

More information

UNDERSTANDING AND USING THE HVAC DESIGN REVIEW FORM

UNDERSTANDING AND USING THE HVAC DESIGN REVIEW FORM Page 1 UNDERSTANDING AND USING THE HVAC DESIGN REVIEW FORM Each of the 38 points of requested information is discussed, and references to the supporting manual are given to substantiate the requirement.

More information